Eligibility, documents, scope, Go/No-Go checksEligibility, required documents, scope of work and Go/No-Go checks for this tender, in one click.
I/C Managing Director
Supply, installation, testing and commissioning of Diesel Generator 2000 KVA with complete accessories at Dudhmotisagar Dairy- Dharuhera.
349860
MDCMPUL/2026-27/101/DHD/DG set 2000 KVA
Open
Electrical Generators
Works
Mehsana
18 documents required · 16 mandatory · 2 optional
₹5,101
Mehsana District Co-operative Milk Producers’ Union Ltd., Mehsana
₹3.0 L
22 Oct 2026
1 Oct 2026
23 Oct 2026
1 Oct 2026
15 Oct 2026
1 Oct 2026
Basic Unit Price
Supply of Diesel Engine with rated capacity of 2000 KVA at 0.8 P.F., 1500 RPM. 4 stroke, multicylinder coupled to brush less type 415 Volts 50 cycle/second self-exited alternator completed with cushy pads, Silencer, Injectors, Advance Gensets Controller, 5C Warranty (5 Critical Parts of Engine - Cylinder Head, Cylinder Block, Camshaft, Crankshaft, Connecting rod, are warranted for 5 Years or 5000Hrs. of operation), Alternator auxiliaries, electronic governor, 24 volts chargeable battery including initial charging of batteries, as per specifications. The DG Sets shall be SILENT TYPE, HE COOLED. Sound proof Canopy & Diesel Tank with all accessories. CAQM Compliant DG sets that meet the CAQM emission standards in accordance with CAQM Direction No. 76, Order No. F.No. A-11018/01/2021-CAQM/15322-15331 dated 29.09.2023. Or further amended any directions as per CPCB. Including (1) Chimney as per Govt. Norms. (Suitable) (2) Cooling System
Coil Cooler for 2000 KVA DG Sets. (HE cooled)
Isolator Panel of Alternator mounted for 2000 KVA DG Sets
Exhaust System
Fuel piping
Supply and fixing of Valves
Earthing
Control Cables
Power Cables
Providing of End Termination of the various sizes of control & power cable
Cable Trays
Liasoning Work
All Documentation including Manuals, Drawings, P&ID etc. & Training
Total Price bid Amount ( Supply, Installation & Commissioning )
Work Description
1 Preparation, submission, and approval of Electrical SLD modification from CEI (Haryana)
for replacement of 1450 KVA transformer with 2500 KVA transformer.
Replacement of existing 1450 KVA transformer with new 2500 KVA transformer (old 1450
KVA transformer buy-back cost to be adjusted).: - 02 nos.
*Supply 2500KVA 11/0.433KV (Make: Crompton Greaves).OLTC+RTCC+AVR ONAN outdoor distribution transformer with all standard accessories as per IS 1180 & GTP Attached. Service charges for erection, oil filtration, testing and commissioning of 2.5MVA 11/0.433 kV, Distribution Transformer on Load Tap Changer +5% to -15% @ 1.25% Dyn11.
Modification of transformer bus duct and adapter from 2500 A to 4000 A as required for 2500 KVA transformer. 1) Retrofitting of 3WT 4000A, 4Pole ACB with Aluminum bus bar (150X10X3 run per phase & 150X10X2 run Neutral), HT Hardware, PVC Insulation Sleeve R.Y.B.N, Bus Bar Support, CT-4000/5A & Feeder wiring. (WITH MATERIAL). (2) Bus Duct Material: (MATERIAL WITH SERVICE) Aluminum bus bar 150X10, PVC Insulation Sleeve R.Y.B.N, Finger Support 3X0- 65nos., 2X10- 22 Nos., Finger Support Chanel-20Nos., MS Chanel-20 Nos, HT Hardware Normal Hardware. (3) Supply of Copper Flexible.
4 Replacement of HT VCB CT from 100/5 A to 150/5 A Job 1
5 New neutral and body earthing for 2500 KVA transformer. Job 1
6 Modification of Main LT Panel bus bar from 2500 A to 4000 A as required for 2500 KVA transformer.
Replacement of Main LT Panel ACB from 2500 A to 4000 A as required for 2500 KVA transformer (Supply of 3WT 4000A 4Pole EDO ACB. SIEMENS)
8 Replacement of Refrigeration Outgoing ACB from 2500 A to 4000 A as required for 2500 KVA transformer. (Supply of 3WT 4000A 4Pole EDO ACB. SIEMENS).
9 Modification of Refrigeration Outgoing ACB bus bar from 2500 A to 4000 A. (service with material)
10 Replacement of Power Factor Improvement (PFI) panel capacity from 400 kVAr to 800 KVAr TR-1 Panel & 500 kvar to 800 kvar TR-2 Panel).
11 Obtaining NOC from CEI, Haryana for installation of 2500 KVA transformer in place of 1450 KVA
12 Application and approval for extension of electrical load up to 3990 KVA from DHBVN, CE (OP) Office
Supply, Installation, Testing & Commissioning (SITC) of 3.5 Core × 400 sq.mm cable including termination, gland, and thimble.
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
RAW_HTML
ICICI Msh Bank Chequ.pdf
General Guidelines for E-Tender and E-Auction_201125.pdf
Step_for_Bidder_Registration on e-auction Portal.pdf
ABG.PBG Format.pdf
Request to collect new Bank Guarantee with IFSC Code ICIC0000257.pdf
Online Vendor Registration Video Tutorials (2).pdf
SITE VISIT CERTIFICATE FORMAT.pdf
DHD 2000 KVA DG set Technical Part B.pdf
DHD 2000 KVA DG set e-tender NIT Part A.pdf
DHD 2000 KVA DG Set Price bid format.xlsx
XLSX
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .