Loading…
Loading…
Tender Value
₹19.7 L
EMD Value
₹19,721
Closing Date
7 Apr 2026, 6:00 pmClosed
Similar tender results from the same govt authority in the past 3 years.
Chief Officer
Construction of Drainage Line and Iconic Street Light in Nagarpalika Various Area @ Kheda Nagarpalika, Kheda Dist. Kheda
285773
2025-26
Open
Civil Works
Kheda
3 documents required · 3 mandatory
₹1,062
Chief Officer Kheda Nagarpalika
₹19,721
12 Mar 2026
12 Mar 2026
12 Mar 2026
7 Apr 2026
12 Mar 2026
Sr No Qty DESCRIPTION OF ITEM Rate PER AMOUNT
Excavation for pipe line trenches for water supply, sewerage
line, manhole etc. all with shoring and struting if required as
per required gradient and line including safety provisions
using site rails and stacking excavated stuff including up to all
required lead cleaning the site etc. complete for all lifts and
strata as specified.
(A) In all sorts of soil and soft murrum
827.00 1.A.1 Upto 1.50 mt depth 102.35 Cu.m
241.50 1.A.2 1.50 mt to 3.00 mt depth 112.70 Cu.m
P.C.C. M-10 levelling Course
Providing and casting in situ mass cement concrete in grade
M-10 (approx. corresp. to prop. 1:3:6) using granite quartzite
trap metal of size 12 mm to 25 mm incl. consolidation curing
3 R. C. C. PIPE (Horizontal Cast)
Providing and supplying ISI Standard R.C.C. pipes (of Sulphate
Resisting Cement) in standard lengths of following class and
diameter suitable for either collar joints or rubber ring joints
including all taxes, insurance, transportation, freight charges,
octroi, inspection charges, loading, unloading, conveyance to
departmental stores, stacking etc. complete. (IS - 458/
1989)Note : One collar should be supplied with each full
length plain ended RCC pipe, cost included in rates below.
One rubber ring should be supplied with each full length
socketed pipe, cost included in rates below.
400.00 Class NP3 Test Pressure 0.7 Kg/sq.cm 150 mm 380.65 Rmt
4 L,L& J of R.C.C. Pipes
Lowering, laying and jointing R. C. C. pipes in C. M. 1:1 1/2 of
following diameters in proper position, grade and alignment
at all level as directed by Engineer-in-charge including
conveyance from stores to site of work, labour, giving
hydraulic testing as per ISI code.11.b Class NP2,NP3,NP4
400.00 Class NP2 Test Pressure 0.7 Kg/sq.cm 150mm 63.63 Rmt
5 Stoneware Pipe
Providing and supplying ISI marked only Standard length
Stoneware pipes in standard lengths of following class and
diameter including all taxes, insurance, transportation,
freight charges, octroi, inspection charges, loading,
unloading, conveyance to departmental stores, stacking etc.
complete. (IS - 651 / 1989)11.2 Class AA
6 L,L& J of Stone Ware Pipes
Lowering, laying and jointing Stone Ware pipes of following
diameters with cement joints in C. M. 1:1 proportion in
proper position, grade and alignment at all level as directed
by Engineer-in-charge including conveyance from stores to
site of work, Jointing material etc. comp.
7 Sewer Manholes
Providing and constructing Sewer manholes, scraper
manholes and unit house connection chamber, as per the
type design in brick masonry in C. M. 1:5 and inside and
outside 20mm thick plastering in C. M. 1:3 necessary 100 mm
coping with reinforcement in R.C.C.M. 200 fixing C. I. steps
and fixing manhole frame and covers (But excluding supply of
manhole frame and covers) over manholes and house
connection chambers and fixing Manhole covers (but
excluding supplying of manhole covers) over scraper
manhole etc. complete, providing and fixing safety chain
wherever necessary as per the stipulations in the type design
complete as per latest CPHEEO manual. (excl. excavation).(A)
Manhole type "A" Circular type having inside diameter of
1200 mm for depth upto 1.5 m depth (for 150 mm to
10.00 1). Manhole type "A" as above but upto 1.0 M depth. 14005.85 No.
2). Extra depth beyond 1.0 M but upto 1.5 M depth for "A"
type manhole above.
(B) Manhole type "B" circular type having inside diameter
of minimum 1500 mm and for depth from 1.5 M to 4.0 M
(for 150 mm to 600 mm dia sewers)
6.00 1). Manhole type "B" as above but upto 1.5 M depth. 24283.40 No.
2). Extra depth beyond 1.5 M but upto 4.00 M depth for "B"
type manhole above.
8 Chamber for House Connection
Providing and constructing rectangular brick masonry
chamber for house connection as per type design in brick
masonry in C. M. 1:3 including M-100 in foundation M-150 in
30.00 benching inside plastering in C. M. 1:3 and outside plastering 9110.30 No
in C. M. 1:3 coping in M200 and fixing RCC precast manhole
frame and covers, but Excl. supply of manhole and cover etc.
complete excl. excavation.
9 RCC precast M.H. Frame & Cover
RCC precast M.H. Frame & Cover Manufacture, supply &
Delivery at store or at site of work precast RCC M.200 Frame
& cover suitable to drainage M.H. and as per type design &
Drawing including cost of reinforcement M.S. Angles or Flat,
curing mold work etc.10.4.A Heavy duty
16.00 1. Frame suitable for 50cm opening of MH 1289.15 No
16.00 2. Cover suitable for 50cm opening of MH 1348.95 No
10.4.C House Connection Chamber light duty
Refilling the pipeline trenches incl. ramming, watering,
10 943.00 consolidating desposal of surplus stuff as directed within a 25.30 Cmt
radius of 3 km.
Total Amount With GST
Total Amount With GST
Add 2.00 % Contigency
SB-2 (Supplying & Installing LED Street Light from Kheda Lovely to Utavarshah Dargah to
Faljibhai House to Petrolpump Ward No. 03)
Sr. No Qty Item Rate Per Amount
Supplying and erecting LED street light / Flood light fittings with
High power White LEDs wattage of 3 Watt and above assembled
on single MCPCB, efficiency more than 130 lm/w and corrosion
free High pressure die cast aluminium housing with smooth finish
powder coated and heat sink extruded aluminium with diffuser
and Polycarbonate optics/ lenses with company mark/name
engraved or embossed 160 to 270 V,Power Factor more than 0.95,
1 10 THD < 10 %, CCT 3000 K to 5700K,Uniformity ratio >0.45, 1823.05 Nos.
Luminaire efficacy> 100 lumens/watt . LED driver efficiency >
%.( fittings required LM-79 & LM-80 certificates)(NOTE: Below
description have shown ranges of Wattage capacity of LED
fittings.The Engineer incharge may select any wattage capacity
between the ranges shown.) (A) Street Light (IP-65), Surge
protection -4KV integral and ,Light must have 440VAC line supply
with over-voltage protection.
Supplying and erecting approved make Conical Pole (Medium Duty
) Made from HR sheet steel. The pole should be made as per IS.
and shall be coated with hot dip galvanizing as per IS
2629/2633/4759, with required base plate and integral Junction
box consist of terminal plate of min 6mm Hylam sheet, standard
2 10 profile 35mmX7.5mm Din-Rail for MCB Mounting, stud type 10169.69 Nos.
terminal and arrangement for cable terminations as erected on
suitable foundation (included) with necessary GI nut-bolts/J-Bolts.
as per details given by manufacturer considering site requirement.
The length of poles are as below.(D) 6 Mtr. Long 70 mm Top X
mm bottom dia, 3 mm thickness
Providing 1:2:4 cement concrete foundation & 70 % PCC from
bottom including excavation for the pole of size 45 x 45 x 100 cm.
3 10 Deep in below ground level with plinth of 45 cm x 45 cm (or 45 cm 809.01 Nos.
dia x 45 cm) high upper ground level with necessary curing and
finishing in approved manner.
( for 4 & 6 mtr pole)
Providing and erecting XLPE (IS:7098)(I)-88 ISI armoured cable
multistrand / Solid Aluminium conductor for 1.1 KV. to be laid on
wall with necessary clamps or in existing trench / pipe of following
size of cables. (B) 4 core 6 Sq. mm
Supplying & erecting earth pit of minimum bore dia.150mm size
approved make Earthing Electrode consisting Pipe-in-Pipe
Technology as per IS 3043-1987 made of corrosion free hot dipped
G.I.Pipes having Outer pipe dia of 50mm having 80-200 Micron
galvanising, Inner pipe dia of 25 mm having 200-250 Micron
galvanising, connection terminal dia of 12mm with constant ohmic
value surrounded by highly conductive compound with high charge
dissipation suitable for following type of applications with
chamber and heavy duty cover. (A)(approved make OEM has to
submit test certificate including value of earth resistance of
installation duly stamped and signed by agency and officer
Incharge has to ensure the value of earthing resistane mentioned
5 2 in test Certificate) & having back filling compound of (B) Inner 8636.51 Nos.
chemical (CCM Compound)- Resistivity:- 0.2 ohm / meter testing as
per IEC 62561-2017, Voltage drop:- < 1 volt at no load & dry form,
Sulphar content:- <2%(C) Back fill Compound :- Earthing
compound should be capable to retain moisture for long time
Necessary test report must be submitted by Agency. (c) For
Electrical Installation covering Transformer Neutrals, Lightning
arrester Earthing, A.C.Plant & Sensitive Computer System(like
Automation, SCADA) i.e independent Earthing in normal soil.
Length of Pipe : 3.00 mtrs
Back filling Compound :2 nos Bags of 25 Kg.
Providing and erecting Street Light pole bracket comprising main B
Class GI pipe of 4.2 cm/require outside dia. complete with suitable
B Class G.I. sleeve tubing of approx. 45cms.length and suitable for
76.5 mm /80mm / required size of pole top having sufficient
fasteners for fixing the brackets and having spread of 1.5.mtr.
6 10 length with 110 deg.with vertical plane & suitable welded stays, 683.77 Nos.
reducer and with check nuts complete painted with one coat of
Red oxide / PU base primer and two coats of Aluminium / PU
paint. paint with following nos of arms. [A] Single Arm Bracket
Supplying & erecting approved make SMC press moulded
composite FRP. loop-in, loop-out approx. 2mm thick box complete
with Bakelite connector strip 5way(3P+N+E),DIN rail for mounting
7 10 mob & hinged doors as per requirement having locking 414.10 Nos.
arrangements with mounting clamp with nuts, bolts & washers
suitable for erection on pole with cable clamps& earth bolt of
following size of box.(B) 250mm x 200mm x 100mm [deep]
Providing & erecting 240 V MCB double pole switch for lighting
Load (B Curve) having 10 KA breaking capacity & confirms to IS :
8828 in existing box having following capacity (A) 6 to 32 Amp.
Making trench in Hard Murrum / Tar Road of suitable width of
cm or required depth for laying any size of cable or locating the
fault all over the run and back filling the same and making the
surface as normal ground.
Providing and erecting Pipe type earthing having 150 cms.long and
2.5 cms. dia. galvanised iron pipe with coupling and buch buried in
specially prepared earth pit complete with necessary 8 SWG earth
For using salt and charcoal / coke as required for pipe type
Supplying & erecting XLPE(IS:7098)(I)-88 ISI unarmoured copper
12 80 cable 1.1 KV grade to be erected as directed of following size. (E) 3 137.36 Mtr.
core 2.5 Sq. mm
Providing & laying approved make Double walled corrugated pipes
(DWC) of polyethylene(conforming to IS 14930 II )with necessary
13 300 connecting accessories of same material at required depth in 62.62 Mtr.
existing trench for laying of cable. below ground / road surface
for enclosing cable (A)50 mm outer dia
Add 3.00% Contingency Rs.
Add 1.00% Quality Control Rs.
Grand Total Rs.
Grand Total Rs.
Say Total Amount
Say Total Amount
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
RAW_HTML
Tender Doc.pdf
Schedule-B.pdf
SBD.pdf
03. ROADWORKSBOOKLET.pdf
04. Electrical Specifications.pdf
Download all tender documents and submit your bid