| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹37.3 LAccepted-AOC | L1 | Accepted-AOC Lowest Bidder | |
| 2 | L2₹39.3 L+₹1.3 L (3.42%)Rejected-Finance | L2 | Rejected-Finance Not the lowest bidder | |
| 3 | L3₹42.2 L+₹4.2 L (11.1%)Rejected-Finance | L3 | Rejected-Finance Not the lowest bidder | |
| 4 | L4₹42.9 L+₹4.9 L (13.0%)Rejected-Finance 7 NO SABJEE MAHAL ORDERLY BAZAR PO PS BARRACKPORE DIST 24 PARGANAS NORTH KOLKATA 700120 | 24 PARAGANAS NORTH | WEST BENGAL | 700120 | L4 | Rejected-Finance Not the lowest bidder | |
| 5 | L5₹43.0 L+₹5.0 L (13.1%)Rejected-Finance | L5 | Rejected-Finance Not the lowest bidder |
Tender Value
Refer Docs
EMD Value
₹79,400
Closing Date
13 Feb 2021, 6:00 pmClosed
GE Barrackpore
Office of the Garrison Engineer Barrackpore, Kolkata-700120
SPECIAL REPAIRS TO BLDG NO. PB-52 AND PB-54, SPECIAL REPAIR TO BLDG NO. NP-02, PROVISION OF BRICK STROM WATER DRAIN, PROVISION OF METERING SWTICH GEAR ROOM AND CERTAIN REVENUE WORKS AT KANCHRAPARA UNDER GE BARRACKPORE
2021_MES_413870_1
8478/E8
Open Tender
Civil Works
Item Rate
180 days
Barrackpore
Refer to tender documents
3 documents required · 3 mandatory
₹500
GE Barrackpore
₹79,400
Yes
11 Mar 2021
19 Jan 2021
15 Feb 2021
19 Jan 2021
13 Feb 2021
2 Feb 2021
Amount
Taking down chowkats with shutters (without taking off shutter from the frames) not exceeding 1.50 Sqm each complete all as specified and directed.
Taking down chowkats with shutters (without taking off shutter from the frames) exceeding 1.50 Sqm and not exceeding 4.00 Sqm each complete all as specified and directed.
Taking down chowkats or frame with shutters (without taking off shutter from the frames) not exceeding 1.50 Sqm each and refixing the same opening after easing and adjusting complete all as specified and directed.
Taking down of shutter of any description not exceeding 1 sqm each complete all as specified and directed.
Taking down cement plaster of any description on brick or stone or concrete surface of wall etc including raking out joints, hacking for key, scrubbing down with water etc complete all as specified and directed.
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing) removing serviceable tiles to store and rubbish off the premises complete all as specified and directed.
Demolition of cement concrete (unreinforced) in ground floor and paving not exceeding 15 cm thickness (below or above ground level) complete all as specified and directed.
Demolition of brick work or stone/boulder masonry, built in cement mortar including all quoins, arches, pillar etc complete all as specified and directed.
Dismantling timber scantlings (un-framed work) 40 sq.cm and over in section, in any position complete all as specified and directed.
Taking up or down steel tubings & connections including cleaning for refixing or removal from site for 15 mm bore pipes complete all as specified and directed.
Taking up or down steel tubings & connections including cleaning for refixing or removal from site for 20 mm bore pipes complete all as specified and directed.
Dismantling of asbestos cement (corrugated, semi-corrugated etc.) sheets in roof coverings complete all as specified and directed.
Dismantling wall and ceiling boards (fibre, pulp, insulation etc) or insulation boards/slabs/blankets, any thickness including cover fillet complete all as specified and directed.
Hacking out old broken glass (any thickness size quality or description) from wooden or steel frame, glazed with putty or fixed with beads etc complete all as specified and directed.
Surface dressing in soft /loose soil not exceeding 15 cm deep (averaging 7.50 cm deep) complete all as specified and directed.
Excavation in trenches for foundation, laying under ground cable, erection of poles, stays in soft/loose soil not exceeding 1.5 meter wide and not exceeding 1.5 meter deep and getting out complete all as specified and directed
Removing surplus excavated materials to a distance not exceeding 50m and depositing where directed at a level not exceeding 1.5m above the starting points in soft/loose soil complete all as specified and directed.
Returning, filling in, including spreading leveling, watering and well ramming in layers not exceeding 25cm soil complete all as specified and directed.
Spreading, levelling and ramming including watering in floors etc layers not exceeding 25 cm thick (material obtained from excavated materials) complete all as specified and directed.
M&L for broken stone or boulders hardcore of gauge not exceeding 63mm, deposited spread and levelled in layers not exceeding 15cm thick, watered and rammed to a true surface complete all as specified and directed.
M&L for broken brick hardcore of gauge not exceeding 63mm, deposited spread and levelled in layers not exceeding 15cm thick, watered and rammed to a true surface complete all as specified and directed.
M&L for RCC (nominal mix) (1:2:4) type B1 (using 20mm graded crushed stone aggregate) as in foundations including rafts, footings, foundation beam, plinth beams, bases for columns etc , basement slabs, under-reamed piles and mass concrete etc complete all as specified and directed.
M&L for RCC (nominal mix) (1:2:4) type B1 (using 20mm graded crushed stone aggregate) as in column, pillar, piers, post and struts etc complete all as specified and directed.
M&L for RCC (nominal mix) (1:2:4) type B1 (using 20mm graded crushed stone aggregate) as in beams, cantilevers, bressummers, lintels over 1.5 m span complete all as specified and directed.
M&L for RCC (nominal mix) (1:2:4) type B1 (using 20mm graded crushed stone aggregate) used as in slab supported on walls, beams and columns in floors, roofs, landing, balconies, canopies, deck slabs and in shelves and like etc complete all as specified and directed.
M&L for RCC (nominal mix) (1:2:4) type B1 (using 20mm graded crushed stone aggregates) as in chajjas complete all as specified and directed.
M&L for providing, cement concrete (1:2:4) type B-1 (using 20mm graded crushed stone aggregate) as in benching and like etc complete all as specified and directed.
M&L for providing, cement concrete (1:2:4) type B-0 (using 12.5mm graded crushed stone aggregate) as in coping including weathering slightly rounded or chamfered angle and throating complete all as specified and directed.
M&L for PCC (1:3:6) type C-1 (using 20 mm graded stone aggregate) used as in foundation, filling and mass concrete, subbase of floor etc complete all as specified and directed.
M&L for PCC (1:3:6) type C1 (using 20mm graded crushed stone aggregate) as in surface channel and drains etc complete all as specified and directed.
M&L for PCC (1:3:6) type C1 (using 20mm graded crushed stone aggregate) as in bed blocks for inserting holdfast/filling of steel frame etc in including necessary form work complete all as specified and directed.
M&L for PCC (1:4:8) type D-2 (using 40 mm graded crushed stone aggregate) as in foundation filling and mass concrete, subbase of floor etc complete all as specified and directed.
M&L extra for forming fair finished drain or channel 30 cm inner girth in cement concrete, using extra cement, including forms, moulds, mitred/ stopped ends etc complete all as specified and directed.
Add or deduct for each 25 mm girth or part there of over or under 30 cm ditto
Supply only integral water proofing compound liquid, complete all as specified and directed.
M&L for brick work with sub class 'B' bricks straight or curved on plan exceeding 6m mean radius, built in cement mortar (1:6) complete all as specified and directed.
M&L for brickwork with subclass 'B' bricks, straight or curved on plan to any radius in half brick thick walls built in cement mortar (1:4) complete all as specified and directed.
M&L for cutting chases, in brick wall and making good to facing where required and pointing in cement mortar (1:3), to ends or edges of landing, steps, cills, sunshades, shelves, lintels etc and cutting chases for concealed water tubing or concealed conduit wiring etc and making good, cutting not exceeding 10cm girth complete all as specified and directed.
M&L for bricks sub class B (using old sized bricks) laid flat, in to sides of drain bedded and jointed in cement mortar (1:6) and pointed in cement mortar (1:3) complete all as specified and directed.
M&L for bricks sub class B (using old sized bricks) brick laid on edges in floors bedded and jointed in cement mortar (1:6) and pointed in cement mortar (1:6) complete all as specified and directed.
S&F for second class hard wood plain, solid, straight chowkats and frames, wrought, framed rebated on the solid, rounded or chamfered put together with glue pinned at joints of second class hard wood etc complete all as specified and directed.
M&L for second class hard wood in scantling, wrought as in frame work, fixed with nails complete all as specified and directed.
S&F for 35mm thick (factory made) plain, second class hard wood, framed, panelled shutters (three panels) with lock rails and panel of 12 mm veneered particle board with commercial veneering on both faces (BWR type), the size of rail and stile as per IS-1003 (Part-I) (larger size to be provided) klin seasoned and chemically pressure treated fitted to chowkats complete all as specified and directed.
S&F for 35mm thick second class hard wood glazed/ gauge & skeleton shutters (factory made), open rebated & prepared to receive glass, gauge etc. (without sash bars) edges of framing plain, chamfered or rounded, fitted with cut & mitered beads for securing glass etc. sizes of members of shutters as specified in SSR part-I, section-8, clause 8.24 (a) (larger size to be provided) complete all as specified and directed.
S&F for 30mm thick second class hard wood glazed/ gauge & skeleton shutters (factory made), open rebated & prepared to receive glass, gauge etc. (with sash bars) edges of framing plain, chamfered or rounded, fitted with cut & mitered beads for securing glass etc. sizes of members of shutters as specified in SSR part-I, section-8, clause 8.24 (a) (larger size to be provided) complete all as specified and directed.
S&F for 35 mm thick flush door shutters (factory made) solid core construction with block board core and plywood face panels commercial type on both sides complete all as specified and directed.
S&F for factory made solid panel PVC door shutter 30 mm thick (style) consisting of frame made out of MS tubes for top & bottom rails, MS frame covered with heat moulded plain colour PVC ‘C’ channel having a PVC sheet strip of 20 mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail; paneling of plain colour PVC sheet to be fitted in the MS frame welded/sealed to the stiles & rails with suitable PVC sheet beading and jointed together with solvent cement, supply and fixing in the frame at site as per clause 8 B.2.1 of MES schedule Part-II (2004) complete all as specified and directed.
S&F for factory made solid PVC door frame of size 50mm X 47mm made out of 5 mm thick plain colour PVC sheet reinforced with MS square tube as per specification and drawing complete all as specified and directed.
M&L for form work to sides of concrete foundation, footing, base of column, raft & plinth beam for flat, rough finish surface of concrete complete all as specified and directed.
M&L for form work to sides of pillar, posts, struts, piers, columns and stanchions for flat, rough finish surface of concrete complete all as specified and directed.
M&L for form work to sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelves including supports, overhangs etc also splays between floors and beams etc for flat, rough finish surface of concrete complete all as specified and directed.
M&L for formwork to the soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work, not exceeding 200 mm thick (horizontal or sloping ) and making flat, rough finished surfaces of concrete complete all as specified and directed
M&L for formwork to edges of concrete flats, treads, breaks in floors, window cills, concrete railings, opening in concrete walls, floor and roofs exceeding 5 cm but not exceeding 10 cm wide for rough finished surfaces of concrete, flat complete all as specified and directed.
M&L for formwork to chullah hoods, chajjas, troughs and similar items including edges for flat, rough finish surface of concrete complete all as specified and directed.
S&F for 75 mm long stainless steel butt hinges, medium weight complete all as specified and directed.
S&F for 100 mm long cold rolled mild steel butt hinges, medium weight complete all as specified and directed.
S&F for 200mm long mild steel barrel tower bolts, stove enamelled black with bright bolt and fixed complete all as specified and directed.
S&F for 150mm long mild steel pressed handles, oval type, stove enamelled black complete all as specified and directed.
S&F for 250 mm long mild steel, sliding door bolt, plate type, stove enamlled black, with bright bolt not less than 12mm dia with and including a minimum of six numbers bolts and nuts, four on bolt plate and two on staple plate complete all as specified and directed.
S&F for 150 mm long aluminium, anodised, barrel tower bolts of extruded section and fixed complete all as specified and directed.
S&F for 100 mm long aluminium, anodised, barrel tower bolts of extruded section and fixed complete all as specified and directed.
S&F for 150 mm long aluminium anodised extruded alloy handle fabricated type complete all as specified and directed.
S&F for 100 mm long aluminium anodised extruded alloy handle fabricated type complete all as specified and directed.
S&F for 300mm long, MS ordinary rat tail rod pattern spring including roller & roller plate complete all as specified and directed.
S&F for 250 mm aluminium , sliding door bolt with sand or die cast brass hasp and staple (bolt type ) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts fixed complete all as specified and directed.
S&F for stainless steel wire cloth, 0.36 mm nominal dia of wire & average width of aperture 1.40mm & fixed with stainless steel wire staple complete all as specified and directed.
S&F for 20mm dia (heavy duty) chromium plated, single curtain rod (wall thickness not less than 1mm) including fancy type PVC powder coated bracket, funnels etc suitable for single curtain rod complete all as specified and directed.
S&F for pressed steel frames for door (factory made) of size 125mm X 60mm of 1.25mm thick with one or more rebates including necessary fittings lugs, hinges, lock strike plate, etc including filling of concrete (1:3:6) type C-0 (using 12.50 mm graded aggregate) back of chowkhats and applying synthetic enamel paint over and including a coat of red oxide primer complete all as specified and directed.
M&L for mild steel framed work such as grills, gratings, etc. with ends of bars shouldered and/or forged into spikes; framed guard bars; barred iron doors; ladders, railings, framed brackets, walk ways, frame work of water tank and similar work conforming to Fe-290-0 Gde-E-165 complete all as specified and directed.
S&F for mild steel screw bolts (machine made) with hexagonal or square heads at one end and screwed the other, or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut, exceeding 5cm not exceeding 10cm long with shank 11mm to 15mm dia complete all as specified and directed.
S&F for mild steel work in square/rectangular tubular trusses and purlins including special shaped washer etc complete using ERW or induction butt welded tubes conforming to IS 1161-1979 grade St-240 complete all as specified and directed.
S&F for rolled mild steel plates (plain or chequred) channels, square cut or notched (ordinary and counter sunk) forming holes with riveted, bolted or welded attachment of Fe 410-W (Gde E-250) quality A complete all as specified and directed.
S&F for mild steel work as in hold fast and similar small articles conforming to Fe-290 Gde-e-165 complete all as specified and directed.
S&F for steel rolling shutter (thickness of laths 1.25 mm) without ball bearing, as specified including top cover, anchoring rod, hasp and staple and applying one shop coat of primer, erected in position as indicated push pull or manual type complete all as specified and directed.
S&F for steel ventilators with top hung shutters (glazed) including box type hinges with steel handle, frame, steel peg stay, complete without glazing bars , dovetailed or welded to receive wire mesh/glass including one coat of red oxide zinc chrome primer at factory complete all as specified and directed.
S&F for steel windows with side hung shutters (glazed/gauged) including box type hinges with steel handle, frame, steel peg stay, complete without glazing bars, dovetailed or welded to receive wire mesh including one coat of red oxide zinc chrome primer at factory complete all as specified and directed.
S&F for factory made steel windows with side hung shutters including box type hinges with steel handle, frame, steel peg stay, complete with glazing bars, dovetailed or welded to receive wire mesh/glass including one coat of red oxide zinc chrome primer at factory complete all as specified and directed.
M&L for TMT bars 10 mm dia and over cut to length bent to shape as required including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia complete all as specified and directed.
M&L for TMT bars 6mm to 8mm dia and over cut to length bent to shape as required including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia complete all as specified and directed.
M&L for TMT bars 5mm dia and over upto and including 10mm dia in stirrups, spacers and binders and binding with and including mild steel wire (annealed) not less than 0.9mm dia complete all as specified and directed.
S&F for anodized aluminium framed for window with one or more rebates, anodized aluminium window, sliding type shutters, sliding on two way aluminium channel, without sash bars, sliding on separate track, made out of aluminium section weighing 0.55 Kg/RM and including necessary jointing cleats, glazing clips, rubber packing, anodized aluminium snap beading, screws, fittings such as suitable anodized aluminium, lock, handle etc and of 4mm thick sheet glass, tinted complete all as specified and directed.
S&F for anodised (powder coating of minimum thickness 50 micron) aluminum frame for doors , windows, ventilators with one or more rebates (sliding & fixed type) including joining cleat for fixing etc complete all as specified and directed
S&F for pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet of 0.50mm thick of any colour as approved by GE having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and directed.
S&F for pre-painted galvalume aluminium zinc coating GI based plain steel sheet of 0.50mm thick of any colour as approved by GE having tensile strength of 550 Mpa as in ridge / wall/cladding, fixed with self tapping screws complete all as specified and directed.
S&F for false ceiling with exposed metal (PPGI) framework/ “Tee” Grid providing and fixing of suspended Tee gird false ceiling using “T” Gird System – powder coated GI (PPGI) exposed grid false ceiling suspension system in grid size 600mm x 600mm with main runner 32 x 24mm x 0.3mm thick, cross tee 26mm x 24mm x 0.3mm thick and wall angle 24mm x 24mm x 0.40mm thick using 4mm thick non asbestos fibre cement board (Make: Everest, type/pattern -oceanic or equivalent of Armstrong/Charminar) of size 595 x 595mm, an asbestos Free fibre cement board manufacture using high Pressure System Curing technology. T gird Framing is suspended using 4mm GI/MS bar hanger fixed with steel dash fasteners or iron purlin from the roof with adjustment clip, also providing provisions for light fixtures, air conditioning diffusers and ducts, sprinklers, smoke detectors etc. The main runners to be secured to structural soffit by hanger @ 1220mm maximum c/c. The last hanger at the end of each main runner should not be placed at not more that 300mm from the adjacent wall. 1220mm/600mm Cross Tee to be interlocked between main runners @ 600mm c/c, so as to from 600mm x 600mm or 1200mm x 600mm grid, confirming IS 14862 & type B category III of ISO 8336, tested as per AS 1530 part – 3 & B. S- 476 part 4,5,6,7 & 8 should be placed in Gird module to form complete all as specified and directed.
M&L for applying evenly a coat of bitumen primer on roof, canopy, chajja, parapet (vertical surface etc) @ 0.40 Litre / Per Sqm by the same membrane manufacturer of density 250C, 0.87 to 0.89 litre and viscosity 70-160 cps after proper cleaning the roof surfaces (horizontal/vertical) and providing APP based polymeric membrane minimum weighing 3.6 Kg/Sqm and minimum 3mm thick reinforced with polyester non wove fabric (weight not less than 150 gms / sqm) laid on primed surface with side over lap of 80 mm and end overlap of 100 mm, using bitumen torch or by LP gas torching and sealing all joints etc and ensuring complete thermo fusing and applying one coat of aluminum paint over it complete all as per manufacturer's instructions complete all as specified and directed.
M&L for 6mm thick fibre asbestos cement, corrugated or semi-corrugated sheets in roofs, walls etc. fixed with 'L' or 'J' type hooks complete all as specified and directed.
M&L for 6mm thick fibre asbestos cement two pieces adjustable serrated ridge for corrugated or semi- corrugated sheets fixed with 'L' or 'J' type hooks complete all as specified and directed.
M&L for 100mm thick PCC (1:4:8) type D-2 (using 40 mm graded crushed stone aggregate) as in subbase of floor complete all as specified and directed.
M&L for 75mm thick PCC (1:3:6) type C1 (using 20mm graded crushed stone aggregate) as in plinth protection/paving including finishing the cement concrete surface even and smooth without using extra cement complete all as specified and directed.
M&L for 75mm thick PCC (1:3:6) type C2 (using 40mm graded crushed stone aggregate), as in sub base of floor complete all as specified and directed.
M&L for 50mm thick PCC (1:3:6) type C1 (using 20mm graded crushed stone aggregate) as in plinth protection/paving including finishing the cement concrete surface even and smooth without using extra cement complete all as specified and directed.
M&L for 40mm thick cement concrete (1:2:4) type B-0 (using 12.5mm graded crushed stone aggregate) as in subbase of floor and finished the surface rough complete all as specified and directed.
Roughening surfaces of old concrete floor by picking, sweeping, clean and washing down with water to remove, dust etc complete all as specified and directed.
M&L for non skid (joint free) ceramic coloured (colour & shade as approved by GE) tiles of 7 to 8 mm thick (square/rectangular) area of each tile exceeding 0.06 sqm but not exceeding 0.11 sqm, in floors etc set and jointed in neat cement slurry and pointed in colour cement to match over and including 15mm thick Screed bed or beading layer of cement mortar (1:6) for laying floor finishes complete all as specified and directed.
M&L for non skid (joint free) ceramic coloured (colour & shade as approved by GE) tiles of 7 to 8 mm thick (square/rectangular) area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm, in floors etc set and jointed in neat cement slurry and pointed in colour cement to match over and including 15mm thick Screed bed or beading layer of cement mortar (1:6) for laying floor finishes complete all as specified and directed.
All as per Item No.96.00 here-in-before but in skirting/dado over and including a backing coat of 10mm thick plaster in cement mortar (1:4) complete all as specified and directed.
S&F for glazed ceramic coloured wall tiles (vertical) 350mm x 250mm x 7mm / 450mm X 300mm X 7mm thick or equivalent as approved GE set and jointed neat cement slurry and pointed in colour cement to match over and including 10 mm thick cement plaster in cement mortar (1:4) complete all as specified and directed.
M&L for machine cut kota stone slab flooring (pre-mirror polished) 20-22mm thick over and including 20mm thick screed bed of cement mortar (1:6), laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing (wax) complete all as specified and directed.
M&L for machine cut kota stone slab 20-22mm thick in riser of steps, skirting, dado and pillar laid over 10mm cement plastering in cement mortar (1:4) and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing (wax) complete all as specified and directed.
M&L for rendering 15mm thick in cement mortar (1:6) on brick work or concrete surfaces of wall, finished even and smooth without using extra cement complete all as specified and directed.
M&L for rendering 15 mm thick, 1st coat 10mm thick in cement mortar (1:6) & 2nd coat 5mm thick in cement mortar (1:4) with water proofing compound as per manufacturer's instructions, plastered surface shall be finished even and smooth without using extra cement complete all as specified and directed. (Note : WPC shall be measured and paid separately, WPC shall be used in second coat only)
M&L for rendering 15mm thick in cement mortar (1:4) on brick works or concrete surfaces finished the surface even and smooth without using extra cement complete all as specified and directed.
M&L for rendering 15mm thick on concrete surfaces in RCC roof surfaces with cement mortar (1:4) with WPC as pre manufacturer's instructions finished the surfaces even and smooth without using extra cement complete all as specified and directed. (Note : WPC will be measured and paid separately)
M&L for rendering 5mm thick in cement mortar (1:3) on ceiling surfaces, finished fair and smooth without using extra cement complete all as specified and directed
M&L for applying three coats of white wash on wall surface including preparation of new plastered surface complete all as specified and directed.
M&L for applying three coats of white wash on surface of ceiling including preparation of new plastered surface complete all as specified and directed.
M&L for applying one coat of white wash on old decorated wall surfaces after preparation of old plastered surfaces complete all as specified and directed.
M&L for applying two coats of oil emulsion distemper over a coat of alkali resistant primer over and including applying 3mm thick wall care putty on old decorated plastered surface of wall after complete removal of existing treatment including preparation of surfaces complete all as specified and directed.
M&L for applying two coats of oil emulsion distemper over a coat of alkali resistant primer over and including applying 3 mm thick wall care putty after preparation of newly plastered surfaces of walls complete all as specified and directed.
M&L for applying two coats of cement based paint over a coat of alkali resistance primer on newly plastered surface of walls including preparation of surface complete all as specified and directed.
M&L for applying two coats of cement based paint over a coat of alkali resistant primer on old plastered surface of walls after complete removal of existing treatment complete all as specified and directed.
S&F for 4.0 mm thick sheet glass tinted fixed with beads complete area exceeding 0.50 Sqm each pane complete all as specified and directed.
S&F for 3.0mm thick sheet glass ordinary quality and glazing with oil putty or fixed with bead/glazing pins in squares not exceeding 0.50 sqm each pane complete all as specified and directed.
M&L for preparing surfaces of wood and wood based materials, new or old, of any description and girth, not otherwise described and treated with two coats of creosote oil complete all as specified and directed.
M&L for applying two coats of synthetic enamel paint over a coat of pink primer after preparation of new wooden surfaces of any description over 10 cm girth or width complete all as specified and directed.
M&L for applying one coat of synthetic enamel paint after preparation of old painted wooden surfaces of any description, not otherwise described, over 10cm in width or girth complete all as specified and directed.
M&L for applying two coats of synthetic enamel paint over and including a coat of red oxide primer after preparation of new steel surfaces of any description over 10cm width or girth complete all as specified and directed.
M&L for applying one coat of synthetic enamel paint after preparation of old painted steel surfaces of any description, over 10cm in width or girth, not otherwise described complete all as specified and directed.
S&F for 15mm dia tubes (medium grade) galvanised, with all fittings and fixed complete to walls and ceilings or laid in floors, wall etc (surface or concealed type) complete all as specified and directed.
S&F for 20 mm dia tubes (medium grade) galvanised, with all fittings and fixed complete to walls and ceilings or laid in floors, wall etc (surface or concealed type) complete all as specified and directed.
Refixing old steel tubings & connections in new or old position (wall, ceiling, floor etc.) for 15mm bore pipes with new fittings etc complete all as specified and as directed. (Note : Pipe shall be obtained from Item No 47.00 above)
S&F for 15mm dia bib taps, fancy type, cast copper alloy with crutch or butterfly handles, screwed down, screwed for iron pipe or for brass ferule, chromium plated with long screw type fixed in repair complete all as specified and directed.
S&F for 15mm dia bib taps, fancy type, cast copper alloy with crutch or butterfly handles, screwed down, screwed for iron pipe or for brass ferule, chromium plated with long screw type fixed complete all as specified and directed.
S&F for 15mm dia pillar taps, cast copper alloy with capstan heads, chromium plated, fancy type, screwed down high pressure, with letter 'HOT' or 'COLD' with long screwed shanks & fly nuts, screwed for iron pipes complete as in repair all as specified and directed.
S&F for 15mm dia pillar taps, cast copper alloy with capstan heads, chromium plated, fancy type, screwed down high pressure, with letter 'HOT' or 'COLD' with long screwed shanks & fly nuts, screwed for iron pipes completeall as specified and directed.
S&F for 15 mm bore stop valve/angular stop cock , fancy type chromium plated with long shank and cup cast copper alloy screwed down high pressure with crutch or butterfly handle screwed both ends for iron pipe or for unions complete as in repair all as specified and directed.
S&F for 15 mm bore stop valve/angular stop cock , fancy type chromium plated with long shank and cup cast copper alloy screwed down high pressure with crutch or butterfly handle screwed both ends for iron pipe or for unions complete all as specified and directed.
S&F for 15 mm bore stop valve, fancy type chromium plated with long shank and cup (concealed type) cast copper alloy screwed down high pressure with crutch or butterfly handle screwed both ends for iron pipe or for unions complete in repair all as specified and directed.
S&F for brass chromium plated tubular towel rail, 20mm dia, D-type, 60cm long between flanges complete as in repair all as specified and directed.
S&F for brass chromium plated tubular towel rail, 20mm dia, D-type, 60cm long between flanges complete all as specified and directed.
S&F for 125mm size brass chromium plated shower roses with arms, swivel joints, including fixing to steel pipe or union complete in repair all as specified and directed.
S&F for 20mm dia gun metal gate valves with iron wheel head screwed both ends for iron pipes or for unions pipes, fixed complete in repair all as specified and directed.
S&F for 20mm dia gun metal gate valves with iron wheel head screwed both ends for iron pipes or for unions pipes, fixed complete all as specified and directed.
S&F for health faucet (ABS) with rubbit cleaning system, one meter long PVC flexible tube for 15mm dia and ABS wall hook complete as in repair all as specified and directed.
S&F for health faucet (ABS) with rubbit cleaning system, one meter long PVC flexible tube for 15mm dia and ABS wall hook complete all as specified and directed.
S&F for glass shelf assembly consisting of 5.5mm thick sheet glass shelf 12cm wide with chromium plated bracket guard and railing 60cm long complete all as specified and directed.
S&F for chromium plated toilet paper holder with stainless steel flap fixed to walls with chromium plated brass screw complete all as specified and directed.
S&F for PVC connection pipe 15 mm size with PTMT nuts of length 450 mm complete all as specified and directed.
S&F for PVC connection pipe 15 mm size with PTMT nuts of length 600 mm complete all as specified and directed.
S&F for 50mm bore low density polyethylene pipes (LDPE) of pressure rating 6kgf/cm2 fixed complete to wall or in floors etc. as in outlet pipe for WHB, urinal etc. complete all as specified and directed.
S&F for 32mm waste coupling of PTMT (half and full threaded) (minimum weight 45gms) completed in repair all as specified and directed.
S&F for shelf of PTMT fixed with and including chromium plated brass screws and wooden/plastic cleats (minimum weight 300gms) complete all as specified and directed.
S&F for 10 Ltrs capacity, PVC valveless, syphonic action type, flushing cistern, low level, white, with inlet, ball valve, float and handle including brackets complete with all internal accessories and fixed to wall and jam nuts on both sides, PVC flush pipe 32mm dia 90cm long fixed properly to inlet of WC and making good to disturbed surfaces of wall or floor complete in repair all as specified and directed.
S&F for 10 Ltrs capacity, PVC valveless, syphonic action type, flushing cistern, low level, white, with inlet, ball valve, float and handle including brackets complete with all internal accessories and fixed to wall and jam nuts on both sides, PVC flush pipe 32mm dia 90cm long fixed properly to inlet of WC and making good to disturbed surfaces of wall or floor complete all as specified and directed.
S&F for PVC water closet seat, white/black colour as required, closed pattern with flat bottom and cover and mild steel chromium plated or aluminium hinging device complete all as specified and directed.
S&F for vitreous china squatting pan 'Orissa' pattern, size 580x440mm white, with integral foot rests with P or S trap (excluding flushing cistern and flush pipe) including connection to trap, and to flushing pipe, anti-syphonage pipe etc complete including making good to floors with PCC bedding (1:5:10) type E2 using 40mm nominal brick ballast and connection to trap with cement mortar all as specified, and making good to floor including demolition of PCC / lime concrete bedding existing pan complete as in repairs all as specified and directed.
S&F for vitreous china wash down water closet pan (pedestal pattern) white with P or S trap (excluding flushing cistern & flush pipe) including connection to trap & to flushing pipe, anti-syphonage pipe etc. complete all as specified and directed.
S&F for vitreous china wash basin, white, flat back, size 550 X 400mm, excluding taps, chain and plug and porcelain stopper but including waste pipe, brackets and cutting for and pinning in ends of brackets or erecting stand as in repair complete all as specified and directed.
S&F for vitreous china bowl urinal flat back, size of 465 x 355 x 265 mm white (minimum) with grating and union for discharge pipe (excluding flushing cistern but including flush pipe and waste pipe) complete including providing and fixing plugs, bedding urinal against wall in cement mortar (1:2) securing urinal to plugs with and including 60mm long brass screws, pointing around urinal back in cement fixing automatic flushing cistern with brackets, flush pipe, grating and union for discharge pipe complete all as specified and directed.
S&F for 500 Ltr capacity rotational moulded polyethylene water storage tanks ISI Marked (cylindrical vertical with closed top) multi layer (three layer) hoisted and fixed in position with cover of tank with its locking arrangement, making hole for inlet, outlet and overflow connection after and including 20mm ball valve high pressure of PTMT (minimum weight 210 gms) including dismantling / taking down old PVC water tank, ball valve etc complete all as specified in SSR Part-I all as specified and directed.
S&F for 1000 Ltr capacity rotational moulded polyethylene water storage tanks (cylindrical vertical with closed top) multi layer (three layer) hoisted and fixed in position with cover of tank with its locking arrangement, making hole for inlet, outlet and overflow connection, including 20mm ball valve high pressure of PTMT (minimum weight 210 gms) including dismantling / taking down old PVC water tank, ball valve etc complete all as specified in SSR Part-I all as specified and directed.
S&F for 500 Ltr capacity rotational moulded polyethylene water storage tanks (cylindrical vertical with closed top) multi layer (three layer) hoisted and fixed in position with cover of tank with its locking arrangement, making hole for inlet, outlet and overflow connection, including 20mm ball valve high pressure of PTMT (minimum weight 210 gms) complete all as specified in SSR Part-I all as specified and directed.
M&L for 100mm dia cast iron floor trap with grating including jointing to waste pipe fixed in cement concrete type B-1 (1:2:4) complete as in repair all as specified and directed.
S&F for 100mm dia CI branch pieces, single (equal or unequal), ordinary or inverted (spigot or socket type) or with parallel branches with oval access door as in repair complete in repair all as specified and directed.
S&F for 100mm dia CI branch pieces, double (equal or unequal), ordinary or inverted (spigot or socket type) or with parallel branches fitted with oval access door complete as in repair all as specified and directed.
S&F for 100mm bore sand cast iron soil, waste and vent pipes in any length with or without ears with cement joints, fixed to wall or in floors complete as in repair all as specified and directed.
S&F for 100 mm dia cast Iron bends (any radius) diminishing piece or tapers (larger bore measured) fixed with oval access door as in repair complete all as specified and directed.
M&L for 450 mm dia reinforced concrete pipes, class NP3, laid and jointed complete with collars complete all as specified and directed.
S&F for 110mm bore PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to walls complete all as specified and directed.
S&F for 110mm bore PVC(SWR) junction single, (single T) equal or unequal providing access door complete as in repair all as specified and directed.
S&F for 110 mm bore PVC (SWR) vent cowl complete all as specified and directed.
S&F for 110 mm bore PVC (SWR) bends any radius complete all as specified and directed.
S&F for 110 mm bore PVC (SWR) bends any radius provided with access door complete all as specified and directed.
S&F for 110 mm bore PVC (SWR) pipes single socketed in any length with rubber ring joints laid in trenches / floor complete all as specified and directed.
S&F for 75 mm bore PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to wall complete all as specified and directed.
S&F for PVC (SWR) reducer socket of 110mmX75mm dia complete all as specified and directed.
S&F for 75 mm bore PVC (SWR) bends any radius complete all as specified and directed.
S&F for 75 mm bore PVC (SWR) vent cowl complete all as specified and directed.
S&F for 75 mm bore PVC (SWR) bends any radius provided with access door complete all as specified and directed.
S&F for 75mm dia PVC (SWR) floor trap plain with grating including jointing with solvent cement complete all as specified and directed.
Taking down existing electric meter carefully from the meter box and re-fixed the same in the existing or new location including supply and fix PVC enclosed for meter box alongwith suitable cut out complete all as specified and directed.
M&L for sub main wiring (concealed) complete with 2 run of 6 sqmm single core copper conductor (ISI marked) cable 1100 volts grade, FR-LSH type, PVC insulated, unsheathed, flexible, multi stranded colour coded cables drawn through and including rigid PVC conduit of size 25 mm dia medium grade (MMS) with all connected accessories such as Bend, Tee, Elbow, Short pieces etc concealed in wall/roofs/floors and including one run of 6 sqmm (green colour) single core copper conductor cable flexible, PVC insulated, unsheathed, multistranded, 1100 volts grade, FR-LSH type as earth continuity conductor connected to common earth dolly and including making good the disturbed surfaces to match with existing surface and colour coat and applying putty including cutting and cheasing as required size for concealed work after and including taking down existing sub-main wiring of any type/size from wall and making good disturbed surface complete all as specified and directed. (Note : Two run of 6 sqmm single core copper conductor cable and one run of 6 sqmm single core copper conductor cable as earth continuity and one run of PVC conduit of 25mm dia shall be measured as one unit)
M&L for sub main wiring (concealed) complete with 2 run of 4 sqmm single core copper conductor (ISI marked) cable 1100 volts grade, FR-LSH type, PVC insulated, unsheathed, flexible, multi stranded colour coded cables drawn through and including rigid PVC conduit of size 20 mm dia medium grade (MMS) with all connected accessories such as Bend, Tee, Elbow, Short pieces etc concealed in wall/roofs/floors and including one run of 4 sqmm (green colour) single core copper conductor cable flexible, PVC insulated, unsheathed, multistranded, 1100 volts grade, FR-LSH type as earth continuity conductor connected to common earth dolly and including making good the disturbed surfaces to match with existing surface and colour coat and applying putty including cutting and cheasing as required size for concealed work after and including taking down existing sub-main wiring of any type/size from wall and making good disturbed surface complete all as specified and directed. (Note : Two run of 4 sqmm single core copper conductor cable and one run of 4 sqmm single core copper conductor cable as earth continuity and one run of PVC conduit of 20mm dia shall be measured as one unit)
M&L for surface point wiring complete with two single core 1.5 sqmm PVC insulated, FR-LSH type, ISI marked, conforming to IS-694/1990 unsheathed, multistranded, single core, copper conductor cable 1100 volts grade colour code cables drawn through and including PVC casing and caping of size 20mm, ISI marked (medium grade) as required at site with all accessories such as Tee, corner, over laping, connector etc on walls / roofs / ceiling etc. flush mounting MS box with top, bottom, side/back wall knockout for casing & caping entry from any direction made out of 1.60mm thick and 50mm depth suitable for fixing of bakelite laminated top cover 3mm thick, blanking plate, numbers of switches, sockets, fan regulators, red colour indicator, blank plates etc as approved coloures accessories of suitable and including 1.5 Sqmm PVC insulated multistranded FR-LSH type unsheathed (Green colour), single core cable with copper conductor cable as earth continuity conductor and connecting to common earth dolly and including making good the disturbed surfaces to match with existing surfaces and applying white/ colour wash/distemper after applying putty for smooth finish surface for the following after and including taking down point wiring with fixtures and fittings complete all as specified and directed :- (Note:- All necessary accessories such as top cover plate, blank plate, MS box, screws, washers etc are to be used of same make/brand only and shall be deemed in to included in quoted rate only.)
One light point controlled by one switch .
One fan point (any type) controlled by one switch and one regulator.
One bell/buzzer point controlled by one bell push.
One 3 pin 5/6 amps socket outlet point on same board.
One 3 pin 5/6 amps socket outlet point on independent board.
All as per Item No.177.00 here-in-before but point wiring with 2.5sqmm PVC insulated multistranded flexible unsheathed copper conductor FR-LSH and earth conductor of size 1.50 sqmm PVC insulated multistranded flexible copper conductor FR-LSH of 3 pin, 15 Amps socket outlet on independent board complete all as specified and directed .
M&L for point wiring (concealed) complete with 1.5 sqmm PVC insulated, FR-LSH type, ISI marked,conforming to IS-694/1990 unsheathed, multistranded, single core, copper conductor cable 1100 volts grade colour code cables drawn through and including PVC Conduit 20 mm dia medium grade (MMS) and including cutting, chasing work at any height and all accessories concealed in walls / roofs / floors / ceiling etc. flush mounting MS box of 1.20mm thickwith top, bottom, side/back wall knockout for conduit entry from any direction made out of 1.60mm thick suitable for fixing of bakelite laminated top cover of 3mm thick , blanking plate as per numbers of switches, sockets, fan regulators, red colour indicator, blank plates etc as approved coloures accessories and including 1.5 Sqmm PVC insulated multistranded FR-LSH type unsheathed (Green colour), single core cable with copper conductor cable as earth continuity conductor and connecting to common earth dolly and including making good the disturbed surfaces to match with existing surface and colour coat including providing putty and white cement for smooth finishing of existing surface complete all as specified and directed for the following:- (Note:- All necessary accessories such as box, top cover plate, blank plate, MS box, screws, washers and all modular electrical fixtures are to be used same make/brand only and shall be deemed in to included in quoted rate only.)
One light point controlled by one switch .
One exhaust fan point controlled by one switch and one regulator.
All as per Item No.179.00 here-in-before but point wiring with 4sqmm PVC insulated multistranded flexible unsheathed copper conductor FR-LSH and earth conductor of size 4sqmm PVC insulated multistranded flexible copper conductor FR-LSH of 3 pin, 15/16 Amps socket outlet on independent board complete all as specified and directed .
S&F for LED 16/18 Watt light fittings suitable for LED T8 lamp, pre wired including necessary electric connection with required size copper cable complete all as specified and directed . (Make : Crompton Greaves cat No : DMLN1LT8-16/ Havells cat No : REGALBATTENT5UPTO1X18WDSBSWH as approved)
S&F for 18 watt linear LED T8 tubular lamp with extruded aluminium body / polycarbonate diffuser with inbuilt driver complete all as specified and directed. (Make: Crompton Greaves Cat No LTT8-20 /Havells Cat No PHOTONULTRA2.01213T8SSTL18WLED865SPC as approved)
S&F for angle lamp holder, insulated body with back plate for batten fittings in and including LED lamp 12 watts complete all as specified and directed. (Make: Philips/Havells/Crompton Greaves as approved)
S&F for stepped type (0-4/5 step) electronic fan regulator for ceiling fan 1200 mm, 240 Volts, 100 Watts to 120 watts single pole, ISI marked including connecting, testing complete all as specified and directed. (Make:Anchor (Penta)/Havells/Legrand as approved)
S&F for socket out let, flush type, 2 in 1, 3/5 pin, 5/6 Amps, 240 volts, ISI marked, AC complete all as specified and directed. (Make:Anchor (Penta)/Havells/Legrand as approved)
S&F for switch piano flush button single pole, one way, 5/6 amp, 240 volts, AC, ISI marked complete all as specified and directed. (Make:Anchor (Penta)/Havells/Legrand as approved)
S&F for socket out let, flush type, 2 in 1, 3/5 pin, 5/6 and15/16 Amps, 240 volts, AC, ISI marked complete all as specified and directed. (Make:Anchor (Penta)/Havells/Legrand as approved)
S&F for switch piano flush button single pole one way 15/16 amp 240 volts, AC, ISI marked complete all as specified and directed. (Make:Anchor (Penta)/Havells/Legrand as approved)
S&F for bell push switch, single pole, one way, flush type, 6 Amps, 240 volts, ISI marked complete all as specified and directed.
S&F for call bell ding-dong sound type, 230 Volts, 50 Hz, AC, ISI marked complete all as specified and directed.
S&F for ceiling rose , surface bakelite 65X50mm, three terminal, PVC/polycarbonate body complete all as specified and directed. (Make:Anchor (Penta)/Havells/Legrand as approved)
S&F for powder coated sheet metal enclosure metal door 415 volts AC,TPN distribution board 4 way suitable for flush mounting with 200 amps copper busbar, neutral bar, earth bar including connecting cable links with top and bottom removable gland plate with IP 43 DBs protection and including making good the disturbed surfaces to match with existing surface and colour code complete as in repair all as specified and as directed. (Make:- Legrand cat No. 5076 70 4 way / Hager Cat No.VYT04DD/ L&T Cat No. DBTPE004GD as approved)
S&F for powder coated sheet metal enclosure acrylic door 240 volts AC, SPN distribution board 8 way for flush mounting with 200amps copper busbar, neutral bar, earth bar including connecting cable links with top and bottom removable gland plate with IP 43 DBs protection and including making good the disturbed surfaces to match with existing surface & colour code complete as in repair and all as specified and directed. (Make: Legrand Cat No. 5076 21 8 way / Hager cat No.VYS08D / L&T Cat No.DBSPN008GD as approved)
S&F for powder coated sheet metal enclosure acrylic door 240 volts AC, SPN distribution board 4 way for flush mounting with 100 amps copper busbar, neutral bar, earth bar suitable for MCB incomer of rating upto 100 Amps, MCB SPN/DP and MCB SP, 10KA as outgoing and complete connecting cable links with top and bottom removable gland plates with IP 43 DBs protection and including making good the disturbed surfaces to match with existing surface and colour coat complete all as specified and as directed. (Make:- Legrand cat No. 5076 20 4 way / Hager cat No.VYS04G / L&T Cat No. DBSPN004GD as approved).
S&F for MCB, four pole, 80 Amps, 'C' Series, 415 Volts, 50Hz, ISI marked complete all as specified and directed. (Make: L&T Cat No.AU15S40803C or equivalent of Legrand/Havells as approved)
S&F for MCB, four pole, 63 Amps, 'C' Series, 415 Volts, 50Hz, ISI marked complete all as specified and directed. (Make: L&T Cat No.BB40630C/Legrand Cat No. 4087 02 or equivalent of Havells as approved)
S&F for MCB, double pole, 40 Amps, 10 KA, "C" series, AC, 240 Volts, 50Hz, ISI marked complete all as specified and directed. (Make: L&T Cat No. BB20400C/Legrand Cat No. 4086 37 or equivalent of Havells as approved)
S&F for MCB, double pole, 20 Amps, 10 KA, "C" series, AC, 240 Volts, 50Hz, ISI marked complete all as specified and directed. (Make: L&T /Legrand / Havells as approved)
S&F for MCB, double pole, 16 Amps , 'C' series, 240 Volt, 10KA, 50 Hz, ISI marked complete all as specified and directed . (Make: L&T Cat No.BB20400C or equivalent of Legrand/Havells as approved)
S&F for MCB, SP, 6 Amps to 32 Amps , 'C' series, 240 Volt, 10KA, 50 Hz, ISI marked complete all as specified and directed (Make: L&T /Havells/Legrand as approved)
S&F for rectangular block for mounting switches, sockets, fan regulator, tub light fittings, ceiling rose etc with 3mm thick plastic laminated sheet cover of size 100mmX100mmX50mm deep complete all as specified and directed.
M&L for earthing complete with galvanised steel earth plate electrode 600mmX 600mmX 6mm thick buried directly in ground vertically ( earth pit not less than 2.25 meters deep below ground level) with top edge of plate not less than 1.5 metres below ground level, connected to and including galvanised iron wire 4 mm dia and light grade protection pipe of 15 mm dia from earth electrode up to test point or up to 7.5mtr whichever is less by means of GI bolts, nuts, check nuts and washers all as per electrical plate No 5 of SSR Pt-I and GI watering pipe of 20 mm dia medium grade, GI funnel with wire mesh including charcoal, salt packed all around the earth electrode plate in layers, PCC earth pit chamber (1:3:6) type C1, of size 45X 45X 45 CM, RCC cover (1:2:4) type B1 of size 45X45X6 CM, excavation/earth work in any strata and returning filling, removal of surplus soil and testing/test point for required value including removing old item complete all as specified and directed. (Galvanised iron wire of 4mm dia upto 7.5m including testing consider in this item).
S&F for exhaust fans, AC, single phase 230V/240V of size 300mm sweep with louver including making hole for fixing of exhaust fan and making good the disturbed surfaces complete all as specified and directed. (Make: Crompton Greaves Cat No.Trans Air 4 Blade/Havells Cat No. Turbojet SP 1400RPM as approved)
M&L for sand cushioning to under ground cable in trenches/existing cable trenches/ducts in layers of 8 cm deep before laying the cable and 15 cm deep including required watering and consolidation after laying and stretching the cable complete all as specified and directed
M&L for brick covering with width equal to length of brick as mechanical protection to cable with well burnt sub class ‘B’ bricks of size 250mm x 125mm x 75mm laid dry flat complete all as specified and directed .
Supply and laying reinforced precast concrete cable cover, class EHV, type-1 with peak, size 450mmX230mmX50mm complete all as specified and directed
M&L for GI pipe 50mm dia (light grade) complete with all fittings in trenches, road/culvert crossing, on wall, floors, on roof, on pole for cable protection complete all as specified and directed.
Supply, fabricated and fixing of street light bracket made out of GI pipe 32mm dia medium grade bent to shape of 1.2 mtr long as directed including clamps made out of 40 mm x 6 mm flat iron for fixing bracket suitable for steel tubular poles including nuts and bolts, washers and other connected items of required size including painting with two coats of aluminium paint over a coat of red oxide primer complete all as specified and directed.
S&F for LED street light fittings Indus series IP-65 powder coated pressure die cast aluminium compact high power LED street light with heat resistant toughened glass of capacity 30 watt with LED lamp complete as in repair all as specified and directed . (Make : Crompton Greaves Cat No LSTS-30-CDL-M/ Havells Cat No ENDURACITYLITEPLATPLUSSL30WLED757SASYBOPC as approved)
M&L for XLPE insulated, LT armoured electric cable with aluminium stranded conductor 1100 volts grade, cross-sectional area 6 sqmm, 2 core laid in trenches/pipes/ducts/wall/borings with necessary cable lugs and glands, nuts, bolts and washers etc and testing complete all as specified and directed. (NOTE: Excavation/earth work, sand cushioning, cable cover/brick shall be measured and paid separately if required)
M&L for XLPE insulated, LT armoured electric cable with aluminium stranded conductor 1100 volts grade, cross-sectional area 10 sqmm, 2 core laid in trenches/pipes/ducts/wall/borings with necessary cable lugs and glands, nuts, bolts and washers etc and testing complete all as specified and directed . . (NOTE: Excavation/earth work, sand cushioning, cable cover/brick shall be measured and paid separately if required)
M&L for XLPE insulated, LT armoured electric cable with aluminium stranded conductor 1100 volts grade, cross-sectional area 25 sqmm, 2 core laid in trenches/pipes/ducts/wall/borings with necessary cable lugs and glands, nuts, bolts and washers etc and testing complete in repair all as specified and directed. (NOTE: Excavation/earth work, sand cushioning, cable cover/brick shall be measured and paid separately if required)
M&L for XLPE insulated, armoured electric cable with aluminium stranded conductor 11000 volts grade, cross-sectional area 120 sqmm, 3 core laid in trenches/pipes/ducts/wall/borings with necessary cable lugs and glands, nuts, bolts and washers etc and testing complete all as specified and directed. (NOTE: Excavation/earth work, sand cushioning, cable cover/brick shall be measured and paid separately if required)
S&F for cable jointing kit for 11 KV grade cable for indoor termination cold shrink type joint complete with jointing material and accessories suitable for 120 sqmm 3 core HT cable complete all as specified and directed.
S&F for cable jointing kit for 11 KV grade cable for outdoor termination cold shrink type joint complete with jointing material and accessories suitable for 120 sqmm 3 core HT cable complete all as specified and directed.
S&F for sheet metal enclosure single pole and neutral with a two pin and earth plug and socket complete including one single pole, MCB 20 Amp, 240Volts, 'C' series, 10KA, ISI marked complete all as specified and directed.
S&F for LED street light fittings Indus series IP-66 powder coated pressure die cast aluminium compact high power LED street light with heat resistant toughened glass of capacity 30 watt with LED lamp complete as in repair all as specified and directed . (Make : Crompton Greaves Cat No LSTS-30-CDL-M/ Havells Cat No ENDURACITYLITEPLATPLUSSL30WLED757SASYBOPC as approved)
Supply, fabricated and fixing of street light bracket made out of GI pipe 32mm dia medium grade bent to shape of 1.2 mtr long as directed including clamps made out of 40 mm x 6 mm flat iron for fixing bracket suitable for steel tubular poles including nuts and bolts, washers and other connected items of required size including painting with two coats of aluminium paint over a coat of red oxide primer complete in repair all as specified and directed.
M&L for fixing of PVC insulated FR-LSH cable with multistranded copper conductor 1100 volt grade of size 6 sqmm for connection from MCB to electric meter by using clips in meter box after and including taking down existing cable of any type and any size complete all as specified and directed. (Note : Two run of 6 Sqmm copper cable shall be measured as one unit length)
SWASTI ENTERPRISES
RISING ENTERPRISE
CHATTERJEE CONSTRUCTION AND SUPPLIERS
M/S PAUL CONSTRUCTION
SHANKAR CONSTRUCTION CO
MANOJ CONSTRUCTION
M/S RAJESH TRADING CO
DAS ENTERPRISE
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .