Executive Engineer (O&M)
Tender for ARC of Erection of HT/LT line,T/C work & Maintenance & U/G Work under ALL scheme for HANSOT SDN UNDER Ankleshwar (O&M) Division.
311601
E-129(2025-26)
Open
Power/Energy Projects/Products/Services
Bharuch
15 documents required · 14 mandatory · 1 optional
₹2,360
DGVCL
₹27,000
5 Jun 2026
5 Jun 2026
5 Jun 2026
12 Jun 2026
5 Jun 2026
Sr. No. Item Code Item Unit FY 2024-25
HT TAPPING FROM THE EXISTING POLE
INCLUDING FIXING OF CROSS ARMS,
CLAMPS ANTI-CLIMBING DEVICES, DANGER
BOARD, INSULATORS ETC. COMPLETE AND
1 9926000001 PAINTING OF FABRICATED MATERIALS AND No.
NUMBERING COMPLETE WITH COST OF
PAINTS AS PER STANDARD SPECIFICATION
BUT EXCLUDING ERECTION OF GUY SET AND
ERECTION OF PSC POLES OF 8 *200 KG
INCLUDING EXCAVATION OF PIT AND
REFILLING OF EARTH, FIXING OFCROSS
ARMS, TOP FITTING CLAMPS ANTI-CLIMBING
DEVICES, INSULATORS ETC. COMPLETE AND
PAINTING OF FABRICATED MATERIALS USED
ON THE POLES AND NUMBERING WITH COST
OF PAINT AS PER STANDARD SPECIFICATION
BUT EXCLUDING ERECTION OF GUY SET AND
ERECTION OF STEEL POLES OF 9 TO
METERS INCLUDING EXCAVATION OF PIT
AND REFILLING OF EARTH, FIXING OFCROSS
ARMS, TOP FITTING CLAMPS ANTI-CLIMBING
DEVICES, DANGER BOARD, INSULATORS ETC.
3 9926000003 COMPLETE AND PAINTING OF STEEL POLE, No.
FABRICATED MATERIALS USED ON THE
POLEAND NUMBERING WITH COST OF PAINT
AS PER STANDARD SPECIFICATION BUT
EXCLUDING ERECTION OF GUY SET AND
ERECTION OF STEEL POLE OF 13 METERS
FOR RAILWAY CROSSING ON BG/MG/NG
LINE FOR 0.400/11/22KV OVERHEAD LINES
I.E INCLUDING EXCAVATION OF PIT &
REFILLING OF EARTH, FIXING CROSS ARMS,
TOP FITTING CLAMPS,ANTI-CLIMBING
4 9926000004 DEVICES DANGER BOARD, INSULATORS ETC. No.
COMPLETE AND PAINTING OF STEEL POLES,
FABRICATED MATERIALS USED ON THE
POLES AND NUMBERING WITH COSTOF
PAINT AS PER STANDARD SPECIFICATION
BUT EXCLUDING ERECTION OF GUY SETS
ERECTION OF DOUBLE POLE STRUCTURE OF
8 METERS 200 KG PSC POLES INCLUDING
EXCAVATION OF PITS & REFILLING OF
EARTHING, FIXING OF CHANNELS,
SUPPORTING ANGLES,CLAMPS, ANTI-
CLIMBING DEVICES DANGER
BOARDS,INSULATORS ETC.COMPLETE AND
PAINTING OF FABRICATED MATERIALS USED
ON THE POLES AND NUMBERING WITH COST
OF PAINT AS PER STANDARD SPECIFICATION
BUT EXCLUDING ERECTION OF GUY SETS
AND EARTHING.(WITHOUT AB SWITCH)
ERECTION OF DOUBLE POLE STRUCTURE OF
9 TO 11 METERS.STEEL POLE INCLUDING
EXCAVATION OF PITS & REFILLING OFEARTH,
FIXING OF CHANNELS, SUPPORTING ANGLES,
CLAMPS,ANTI-CLIMBING DEVICES DANGER
BOARDS, INSULATORS ETC.COMPLETE &
PAINTING OF POLES,FABRICATED
MATERIALSUSED ON THE POLES AND
NUMBERING WITH COST OF PAINTSAS PER
STANDARD SPECIFICATION BUT EXCLUDING
ERECTION OF GUY SET AND
EARTHING.(WITHOUT AB SWITCH)
ERECTION OF DOUBLE POLE STRUCTURE
WITH MOUNTING OF AB SWITCH, HG FUSES
OF 8 MTRS 200 KG PSC POLES INCLUDING
EXCAVATION OF PITS AND REFILLING OF
EARTH,FIXING OF CHANNELS SUPPORTING
ANGLES, CLAMPS, ANTI-CLIMBING DEVICES,
7 9926000007 DANGER BOARDS, INSULATORS,DOFUSES No.
ETC. COMPLETE AND PAINTING OF
FABRICATED MATERIALS USED ON THE
POLES AND NUMBERING WITH COSTOF
PAINT AS PER STANDARD SPECIFICATION
BUT EXCLUDINGOF ERECTION OF GUY SET
AND EARTHING.(WITH AB SWITCH)
ERECTION OF DOUBLE POLE STRUCTURE
WITH MOUNTING OF AB SWITCH,HG FUSES,
9 TO 11 METERS STEEL POLES INCLUDING
EXCAVATION OF PITS AND REFILLING OF
EARTH, FIXING OFCHANNEL, SUPPORTING
ANGLES, CLAMPS, ANTI-CLIMBING DEVICES
8 9926000008 DANGER BOARDS, INSULATORS, ETC. No.
COMPLETE AND PAINTING OF POLES
FABRICATED MATERIALS USED ON THE
POLES AND NUMBERING WITH COST OF
PAINT AS PER STANDARD SPECIFICATION
BUT EXCLUDING ERECTION OF GUY SET AND
EARTHING.(WITH AB SWITCH)
ERECTION OF DOUBLE POLE STRUCTURES
WITH MOUNTING OFAB SWITCH, HG
FUSES, TRANSFORMERS, LIGHTENING
ARRESTORS, DISTRIBUTION BOX. OF
METER,200KG PSC POLE METERS POLES
INCLUDING EXCAVATION OF PITS AND
REFILLING OF EARTH, CARTING OF
TRANSFORMERS FROMSTORES TO SITE,
FIXING OF CHANNELS, SUPPORTING
ANGLES,BRACINGS CROSS ARMS CLAMPS,
ANTICLIMBING DEVICES DANGER BOARDS,
CONDUCTOR AND CABLE WIRING
ETC.COMPLETE AND PAINTING OF
FABRICATED MATERIALS USEDON THE POLES
AND NUMBERING WITH COST OF PAINT AS
PER STANDARD SPECIFICATION BUT
EXCLUDING ERECTION OF GUY SETS AND
ERECTION OF DOUBLE POLE STRUCTURE
WITH MOUNTING OF AB SWITCH,HG FUSES
TRANSFORMERS, LIGHTENING ARRESTORS,
DISTRIBUTION BOX 9 TO 11 METERS STEEL
POLES INCLUDING EXCAVATION OF PITS &
REFILLING OF EARTH CARTING OF
TRANSFORMERS FROM STORE TO SITE,
FIXINGOF CHANNELS SUPPORTING ANGLES,
BRACING, CROSS ARMS,CLAMPS,
ANTICLIMBING DEVICES, DANGER
BOARDS,CONDUCTOR AND CABLE WIRING
ETC. COMPLETE AND PAINTING OF POLES
FABRICATED MATERIALS USED ON THE
POLES AND NUMBERING AS PER STANDARD
SPECIFICATION BUT EXCLUDING ERECTIONS
OF GUY SETS AND EARTHING.
ERECTION OF GUY SET INCLUDING
EXCAVATION OF PITS & REFILLING OF EARTH
AS PER STANDARD SPECIFICATION WITH
11 9926000011 STAY CLAMPS, STAY WIRE, ANCHOR ROD, No.
TURN BUCKLE, EYEBOLT, GUY INSULATOR,
CEMENT CONCRETE BLOCK ETC. BUT
EXCLUDING CONCRETING.
CONCRETING OF POLES, GUYS, ETC.
INCLUDING COST OF CEMENT SAND METAL
12 9926000012 (1:2:4) AND WATER ETC. AS PER STANDARD CMT
SPECIFICATION.(cement Should be 53 grade)
used for Concreting.
ERECTION OF COIL TYPE EARTHING
INCLUDING COST OF COAL,SALT ETC. BUT
13 9926000013 WITHOUT COST OF GI WIRE AS PER No.
STANDARD SPECIFICATION(20kg solt+20kg
ERECTION OF GI PIPE/CI PLATE TYPE
EARTHING INCLUDINGCOST OF COAL SALT
14 9926000014 ETC. BUT WITHOUT COST OF PIPE/GIPLATE No.
GI WIRE AS PER STANDARD
SPECIFICATION.(20kg solt+20kg coal)
ERECTION OF STREET LIGHT FIXTURE
COMPLETE WITH CLAMPS, BRASS NIPPLE,
BRASS HOLDER TECK WOOD
BUSH,REFLECTORS FUSE, WIRING ETC. AS
PER STANDARD SPECIFICATION BUT
EXCLUDING COST OF MATERIALS.
OF(30mm2)ACSR/34MM@,55MM2 AAA
CONDUCTOR for ALL TYPE OF CONDUCTOR
16 9926000016 ONE COND PER KM
(EXCEPT DOG CONDUCTOR) FOR 11/22KV &
LT LINES INCLUDING FIXING OF INSULATORS,
BINDING JUMPERING ETC.
STRINGING OF GI WIRE 8 SWG INCLUDING
BINDING JUMPERING ETC.
PROVIDING SINGLE PHASE SERVICE
CONNECTION WITH PVC 2.5/4MM2 TWIN
CORE CABLE FROM TERMINAL POLE TO
18 9926000018 METERING POINT INCLUDING FIXING OF No.
METER WITH METER EARTHING COMPLETE
WORK AS PER STANDARD SPECIFICATION
BUT EXCLUDING COST OF MATERIALS.
PROVIDING THREE PHASE 4 WIRE SERVICE
CONNECTION WITH PVC 4MM2/10MM2
FOUR CORE CABLE FROM TERMINAL POLE
19 9926000019 TO METERING POINT INCLUDING FIXING OF No.
METER WITH METER EARTHING COMPLETE
WORK AS PER STANDARD SPECIFICATION
BUT EXCLUDING COST OF MATERIALS.
ADDITIONAL COST FOR EXCAVATION OF PIT
IN HARD ROCK AREA FOR ERECTION OF
POLE/ GUY ETC. AS PER STANDARD
SPECIFICATION OVER & ABOVE NORMAL
20 9926000020 COST COVERED AGAINST EXCAVATION OF No.
PIT UNDER NORMAL SOIL FOR ERECTION OF
POLE,GUY, DOUBLE POLE STRUCTURE
EARTHING WITH THE APPROVAL OF
SUPDT.ENGINEER.
PROVIDING GUARDING TO HT LINE ON
ROAD/ RAIL CROSSING.
PROVIDING GUARDING OF LT LINES ON
ROAD/RAIL CROSSING.
23 9926000023 LT LINE TAPPING- SINGLE PHASE No.
24 9926000024 LT LINE TAPPING- THREE PHASE No.
Stringing/LAYING OF OVER HEAD LT CABLE
FOR ROAD CROSSING,HT LINE CROSSING
AND TELEPHONE LINE CROSSING ETC.(PER
ERECTION OF SINGLE POLE STRUCTURES
WITH , HG FUSES,TRANSFORMERS,
LIGHTENING ARRESTOR, DISTRIBUTION BOX.
ON 8 METERS 200 KGAND PSC POLE
INCLUDING EXCAVATION OF PITS AND
REFILLING OF EARTH, CARTING OF
TRANSFORMERS FROM STORES TO SITE,
FIXING OF CHANNELS, SUPPORTING
26 9926000026 ANGLES,BRACINGS CROSS ARMS CLAMPS, No.
ANTICLIMBING DEVICES DANGER BOARDS,
CONDUCTOR AND CABLE WIRING
ETC.COMPLETE AND PAINTING OF
FABRICATED MATERIALS USED ON THE POLE
AND NUMBERING WITH COST OF PAINT AS
PER STANDARD SPECIFICATION BUT
EXCLUDING ERECTION OFGUY SETS AND
ERECTION OF SINGLE POLE STRUCTURES
WITH MOUNTING OFAB SWITCH , HG
FUSES,TRANSFORMERS,
LIGHTENINGARRESTOR, DISTRIBUTION BOX.
ON 9 to 11 METERS RSJ POLE INCLUDING
27 9926000027 EXCAVATION OF PITS AND REFILLING OF No.
EARTH, CARTING OF TRANSFORMERS FROM
STORES TO SITE, FIXING OF CHANNELS,
SUPPORTING ANGLES,BRACINGS CROSS
ARMS CLAMPS, ANTICLIMBING DEVICES
DANGER BOARDS, CONDUCTOR AND CABLE
WIRING ETC.COMPLETE AND PAINTING OF
FABRICATED MATERIALS USED ON THE POLE
AND NUMBERING WITH COST OF PAINT AS
PER STANDARD SPECIFICATION BUT
EXCLUDING ERECTION OFGUY SETS AND
ERECTION OF PSC POLES OF 10 *270 KG
INCLUDING EXCAVATION OF PIT AND
REFILLING OF EARTH, FIXING OF CROSS
ARMS, TOP FITTING CLAMPS ANTI-CLIMBING
DEVICES, INSULATORS ETC. COMPLETE AND
PAINTING OF FABRICATED MATERIALS USED
ON THE POLES AND NUMBERING WITH COST
OF PAINT AS PER STANDARD SPECIFICATION
BUT EXCLUDING ERECTION OF GUY SET AND
ERECTION OF DOUBLE POLE STRUCTURE OF
10 METERS 270 KG PSC POLES INCLUDING
EXCAVATION OF PITS & REFILLING OF
EARTHING, FIXING OF CHANNELS,
SUPPORTING ANGLES,CLAMPS, ANTI-
CLIMBING DEVICES DANGER
BOARDS,INSULATORS ETC.COMPLETE AND
PAINTING OF FABRICATED MATERIALS USED
ON THE POLES AND NUMBERING WITH COST
OF PAINT AS PER STANDARD SPECIFICATION
BUT EXCLUDING ERECTION OF GUY SETS
AND EARTHING.(WITHOUT AB SWITCH)
STRINGING OF 100MM2 ACSR/100MM2
AAAC CONDUCTOR FOR 11/22KV & LT LINES
30 9926000030 ONE COND PER KM
INCLUDING FIXING OFINSULATORS, BINDING
STRINGING OF DOG CONDUCTOR FOR
31 9926000031 11/22KV & HT LINES INCLUDING FIXING OF ONE COND PER KM
INSULATORS, BINDING JUMPERING ETC.
ERECTION OF DOUBLE POLE STRUCTURES
WITH MOUNTING OF AB SWITCH, HG
FUSES, TRANSFORMERS, LIGHTENING
ARRESTORS, DISTRIBUTION BOX. OF
METERS 270 KGAND PSC POLES INCLUDING
EXCAVATION OF PITS AND REFILLING OF
EARTH, CARTING OF TRANSFORMERS
FROMSTORES TO SITE, FIXING OF
32 9926000032 CHANNELS, SUPPORTING ANGLES,BRACINGS No.
CROSS ARMS CLAMPS, ANTI-CLIMBING
DEVICES,DANGER BOARDS, CONDUCTOR
AND CABLE WIRING ETC.COMPLETE AND
PAINTING OF FABRICATED MATERIALS USED
ON THE POLES AND NUMBERING WITH COST
OF PAINT AS PER STANDARD
SPECIFICATION BUT EXCLUDING ERECTION
OF GUY SETS AND EARTHING.
DISMENTALLING OF 8 MTR PSC POLE WITH
CREDITING OF FABRICATION AT STORE &
STACKING OF POLE SAFELY ON ROAD SIDE
OR CREDITING TO DEPARTMENTAL STORE
DISMENTALLING OF 10 MTR PSC POLE WITH
CREDITING OF FABRICATION AT STORE &
STACKING OF POLE SAFELY ON ROAD SIDE
OR CREDITING TO DEPARTMENTAL STORE
DISMENTALLING OF TRANSFORMER CENTRE
(8 MTR PSC POLE) (WITH TRANSFORMER)
WITH CREDITING OF FABRICATION &
TRANSFORMER AT STORE & STACKING OF
POLE SAFELY ON ROAD SIDE OR CREDITING
TO DEPARTMENTAL STORE
DISMENTALLING OF TRANSFORMER CENTRE
(8 MTR PSC POLE) (WITHOUT
TRANSFORMER) WITH CREDITING OF
FABRICATION AT STORE & STACKING OF
POLE SAFELY ON ROAD SIDE OR CREDITING
TO DEPARTMENTAL STORE
STRINGING OF LT ABC OF 1*35 SQ MM +
1*25 SQ MM INCLUDING FITTING OF ALL
ACESSARIES I.E. SPECIAL DESIGN
SUSPENSION / TENSION CLAMP, FIXING OF
CROSS ARM, LT SHACKLE INSULATOR ETC.
FOR FIXING OF MESSENGER WIRE AND TO
PROVIDE SERVICE CONNECTION ON AERIAL
BUNCH CABLE BY INSULATED PIERCEING
CONNECTORS THROUGH SERVICE
CONNECTION BOX COMPLETE AS REQUIRED
& DIRECTED BY ENGINEER IN CHARGE.
STRINGING OF LT ABC OF 3*50 SQ MM
+1*25 SQ MM+1*35 SQ MM INCLUDING
FITTING OF ALL ACESSARIES I.E. SPECIAL
DESIGN SUSPENSION / TENSION CLAMP,
FIXING OF CROSS ARM, LT SHACKLE
38 9926000038 INSULATOR ETC. FOR FIXING OF MESSENGER KM
WIRE AND TO PROVIDE SERVICE
CONNECTION ON AERIAL BUNCH CABLE BY
INSULATED PIERCEING CONNECTORS
THROUGH SERVICE CONNECTION BOX
COMPLETE AS REQUIRED & DIRECTED BY
ENGINEER IN CHARGE.
STRINGING OF 11KV ABC OF 3*95 SQ MM
+80 SQ MM INCLUDING FITTING OF ALL
ACESSARIES I.E. SPECIAL DESIGN
SUSPENSION / TENSION CLAMP, FIXING OF
CROSS ARM, BINDING TO PIN
INSULATOR,PREPARING SHACKLE
POINT,JUMPERS ETC. AS REQUIRED &
DIRECTED BY ENGINEER IN CHARGE
STRINGING OF 22 KV ABC OF 3*70 SQ MM
+95 SQ MM INCLUDING FITTING OF ALL
ACESSARIES I.E. SPECIAL DESIGN
SUSPENSION / TENSION CLAMP, FIXING OF
CROSS ARM, BINDING TO PIN
INSULATOR,PREPARING SHACKLE
POINT,JUMPERS ETC. AS REQUIRED AND
DIRECTED BY ENGINEER IN CHARGE
STRINGING OF LT ABC OF 2*50 SQ MM
+1*25 SQ MM+ 35 SQ MM INCLUDING
FITTING OF ALL ACESSARIES I.E. SPECIAL
DESIGN SUSPENSION / TENSION CLAMP,
FIXING OF CROSS ARM, LT SHACKLE
INSULATOR ETC. FOR FIXING OF MESSENGER
WIRE AND TO PROVIDE SERVICE
CONNECTION ON AERIAL BUNCH CABLE BY
INSULATED PIERCEING CONNECTORS
THROUGH SERVICE CONNECTION BOX
COMPLETE AS REQUIRED & DIRECTED BY
ENGINEER IN CHARGE.
DISMENTALING OF RSJ (9/11 METER) POLE
42 9926000042 AND CREDITING THE OLD MATERIAL TO No.
DISMENTALING OF TRANSFORMER CENTER
ON 10MTR,270KG PSC POLE(WITHOUT
TRANSFORMER) WITH CREDITING OF
FABRICATION AT STORE AND STACKING OF
POLE SAFELY ON ROAD SIDE OR CREDITING
TO DEPARTMENTAL STORE
DISMENTALING OF TRANSFORMER CENTER
ON 10MTR,270KG PSC POLE(WITH
TRANSFORMER) WITH CREDITING OF
FABRICATION AT STORE AND STACKING OF
POLE SAFELY ON ROAD SIDE OR CREDITING
TO DEPARTMENTAL STORE
DISMENTLING OF 11KV ABC OF 3*95 SQ MM
+80 SQ MM AND CREDITING FITTING OF
ALL ACESSARIES AND FABRICATION TO
DEPARTMENTAL STORE
DISMENTLING OF 22 KV ABC OF 3*70 SQ
MM +95 SQ MM AND CREDITING FITTING
OF ALL ACESSARIES AND FABRICATION TO
DEPARTMENTAL STORE
DISMENTALING OF LT ABC OF 1*35 SQ MM +
1*25 SQ MM AND CREDITING FITTING OF
ALL ACESSARIES TO DEPARTMENTAL STORE.
DISMENTALING OF LT ABC OF 3*50 SQ MM
48 9926000048 +1*25 SQ MM+1*35 SQ MM AND KM
CREDITING FITTING OF ALL ACESSARIES TO
DEPARTMENTAL STORE.
DISMENTALING OF LT ABC OF 2*50 SQ MM
49 9926000049 +1*25 SQ MM+ 35 SQ MM AND CREDITING KM
FITTING OF ALL ACESSARIES TO
DEPARTMENTAL STORE.
RESTRINGING OF ALL TYPE OF CONDUCTOR
(EXCEPT DOG CONDUCTOR) FOR 11/22KV &
50 9926000050 ONE COND PER KM
LT LINES INCLUDING FIXING OF INSULATORS,
BINDING JUMPERING ETC.
RESTRINGING OF DOG CONDUCTOR FOR
51 9926000051 11/22KV HT LINES INCLUDING , BINDING ONE COND PER KM
LABOUR CHARGE FOR THE INSTALLATION OF
52 9926000052 NEW DTR METER. (METER WILL BE No.
PROVIDED BY DGVCL)
LABOUR CHARGE FOR THE REPLACEMENT
OF DTR METER AND OLD METER SHOULD BE
CREDITED TO SDN STORE. (METER WILL BE
PROVIDED BY DGVCL)
LABOUR CHARGE FOR PROVIDING CT COIL
54 9926000054 FOR DTR METER CONNECTION. (CT COIL PER CT
WILL BE PROVIDED BY DGVCL)
LABOUR CHARGE FOR REPLACEMENT OF CT
COIL FOR DTR METER CONNECTION AND
55 9926000055 OLD CT SHOULD BE CREDITED TO SDN PER CT
STORE. (CT COIL WILL BE PROVIDED BY
LABOUR CHARGE FOR FIXING OF MMB FOR
56 9926000056 DTR METER (MMB WILL BE PROVIDED BY No.
LABOUR CHARGE FOR REPLACEMENT OF
57 9926000057 DTR METER BOX. (METER WILL BE No.
PROVIDED BY DGVCL)
PROVIDING / REPLACEMENT OF 1.5 SQ MM
58 9926000058 10 CORE COPPER CABLE 3.5 METER (CABLE No.
TO BE PROVIDED BY AGENCY)
LABOUR CHARGE FOR
PROVIDING/RECONNECTION OF TERMINAL
59 9926000059 PER TERMINATION
CONNECTION WITH PROPER SIZE OF LUGS.
(LUGS COST IS BORNE BY AGENCY)
LABOUR CHARGE FOR THE SPOT READING
OF DTR METER WITH DETAIL SURVEY OF
DEFECT IF ANY. A DULY SIGN COPY BY
SURVEYOR PERSON OF AGENCY IN PRO-
60 9926000060 FORMA REPORT SHOULD BE SUBMITTED TO PER DTR
SDN OFFICE.(* ONLY IF ALL PARAMETER OF
VOLTAGE, CURRENT & LOAD AS SHOWN IN
PER-FORMA IS FILLED) AS PER THE
INSTRUCTION OF ENGINEER IN-CHARGE.
LABOUR CHARGE FOR THE SPOT READING
OF DTR METER WITH DETAIL SURVEY OF
DEFECT IF ANY. A DULY SIGN COPY BY
SURVEYOR PERSON OF AGENCY IN PRO-
FORMA REPORT SHOULD BE SUBMITTED TO
SDN OFFICE. (DULY FILL PER-FORMA IN
FAULT CONDITION IN WHICH READING
PARAMETER IS NOT SHOWN IN METER)
INSTALLATION OF DTR METER INCLUDING
METER BOX, PROVIDING & FIXING OF 1.5SQ
MM SINGLE STRAND 10 CORE ARMOURED
COPPER CABLE (3.5METER), TERMINATION
IN METER & COIL ETC.(METER, METER BOX,
C.T./P.T. COIL WILL BE PROVIDED BY DGVCL)
INSTALLATION OF DTR METER INCLUDING
METER BOX, TERMINATION IN METER &
63 9926000063 COIL ETC. (WITHOUT 10CORE COPPER No.
CABLE) (METER, METER BOX, C.T./P.T. COIL
WILL BE PROVIDED BY DGVCL)
Binding of messanger Conductorat with a
distance not more than 0.75 mtr with
64 9926000064 turns minimum on XLPE Cable with single No
strand binding wire (including cost of binding
Supply and Installation of 11/22 kV
Distribution Transformers HT Terminal
65 9926000086 protector (UV Resistance) with using PER SET
95/120/150 sq.mm long barrel aluminum
lug. (1Set = 3 Nos i.e. on R, Y, B)
Supply & Installation of HT EPR Tap on 11/22
kV Distribution Transformer with
replacement of bare conductor by HT ABC
66 9926000087 conductor (DO bottom side to transformer) PER SET
after removal of semi conductor by HT ABC
(6 inch both side). HT ABC to be supplied by
DGVCL. (1Set = 3 Nos i.e. on R, Y, B)
Supply, Installation, Testing and
Commissioning of Maintenance Free, Ready
Capsule, Pipe-In-Cage (Pic) Type, Earth
67 9926000088 Electrodes for HT Feeder Pole Having 2000 NO
mm Electrode Length as per the Tender
Specifications and Drawing. (All Materials
Will Be Supplied By Agency)
Supply, Installation, Testing and
Commissioning of Maintenance Free, Ready
Capsule, Pipe-In-Cage (Pic) Type, Earth
68 9926000089 Electrodes for HT Feeder Pole Having 3000 NO
mm Electrode Length as per the Tender
Specifications And Drawing. (All Materials
Will Be Supplied By Agency)
Supply and Installation of 25 X 3 mm GI Strip
having hot dip- galvanized-zinc coating of
80-100 microns without any joints or
welding. Both the end of the GI strip should
be connected with GI nut bolts and required
fabrication work for giving separate earthing
(1) Neutral of the transformer
(2) MS structures of the transformer center
(Approximately 25 meter GI strip per
transformer centre
- as per requirement and instruction of
Engineer in- charge) (All Materials will be
supplied by Agency)
Supply and Installation of uPVC standard
make Pipe of 1.25" diameter for covering GI
strip with UV protected Cable Ties of 550 X
7.6 mm size to bind with pole
face(Approximately 25 meter uPVC pipe for
GI strip covering per transformer centre -as
per requirement and instruction of Engineer
Supply & fixing of upto 33 kV
Conductor sleeve for Busbar to Drop
out Fuse and Drop out fuse to
71 9926000093 Transformer H.T. including Busbar (12 Per TC
mm sleeve) as per technical
specification. (All Materials will be
supplied by Agency)
Supply & fixing of upto 33 kV
Conductor sleeve for Busbar to Drop
out Fuse and Drop out fuse to
9926000100 Transformer H.T. without Busbar (12 Per TC
mm sleeve) as per technical
specification. (All Materials will be
supplied by Agency)
Supply & fixing of upto 33 kV
Conductor sleeve for Busbar to Drop
out Fuse and Drop out fuse to
72 9926000094 Transformer H.T. including Busbar(15 Per TC
mm sleeve) as per technical
specification. (All Materials will be
supplied by Agency)
Supply & fixing of upto 33 kV
Conductor sleeve for Busbar to Drop
out Fuse and Drop out fuse to
9926000101 Transformer H.T. without Busbar(15 Per TC
mm sleeve) as per technical
specification. (All Materials will be
supplied by Agency)
Supply & fixing of Disc type Red Color
FRP(Non-flammable) material with Weather
resistant, Non-conductive bird guard
OD=300 MM, ID=33 MM, Width =1.25 MM,
one side cut from ID to OD. (All Materials
will be supplied by Agency)
Providing and fixing of LT Terminal
protectors i.e. Re-useable boot (LT Side
74 9926000096 kV) including LT (1.1 kV) insulating taps. All No
live part at LT side shall be covered with
fixing of LT insulating taps.
75 Nylon Net around Transformer Center
76 9926000097 Nylon Net (12 * 15 ft) Per Net
77 9926000098 Nylon Dori Per TC
Labour charge for fitting Nylon Net (All
78 9926000099 fabricated material for fitting nylon net shall Per TC
be provided by DGVCL)
Cutting of Tree branches surounding HT/LT
79 9924000001 Per Tree
Replacement of old jumpers & providing
80 9924000002 new double jumpers with 8" binding [D No.
Type] & capsuling with PVC pipe etc
81 9924000005 Support pole for Stay PSC/STP/RSJ No.
Pin binding of conductor 11/22kv Pin
Pin binding of conductor 11/22kv Pin
83 9924000007 insulator per pole in costle area with No.
84 9924000008 Pin binding of conductor LT shakel insulator No.
Replacement of one/both disc.insulator at
Replacement of LT shackle insulator at cut
87 9924000011 Refixing of V cross Arm No.
Replacement of V cross Arm (With
Transportation & Painting)
89 9924000013 Refixing of Top fitting in proper position No.
90 9924000014 Replacement of Top fitting No.
91 9924000015 Replacement of LT cross Arm No.
Providing DO fuse on DP with carting &
jumpuring(ONE DO FUSE)
Numburing of pole with paint by preparing
93 9924000017 back ground of one colour and have No.
lettering(height 3" * width 0.5") using stensil
94 9924000018 Fixing of MMB(1PH.) at consumer end No.
95 9924000019 Fixing of MMB(3PH.) at consumer end No.
96 9924000020 Replacement of (1ph.) meter for Urban area No.
97 9924000021 Replacement of (1ph.) meter for Rural area No.
painting consumer no. on MMB (Urban)
(with letter size height 40mm* width 8mm)
painting consumer no. on MMB (Rural)
(with letter size height 40mm* width 8mm)
Replacement of deteriorated Single phase
Fixing of new dist. Box with complete wiring
including clamps,nut bolts etc.
Reparing of guarding involving reshaping of
bearer wire cross lacing binding etc.
Painting of steel fabricated material of RSJ
DO DP structure with paint
Painting of steel fabricated material of RSJ
104 9924000028 pole mounted transformer double pole No.
structure with paint
Painting of steel fabricated material of RSJ
single pole with paint
painting of steel fabricated material of PSC
Single pole (HT line) with paint
painting of steel fabricated material of PSC
DO DP double pole with paint
painting of steel fabricated material of PSC
108 9924000032 double pole at pole mounted transformer No.
109 9924000033 Providing line seperater single phase No.
110 9924000034 Providing line seperater three phase No.
Replacement / Providing of stay insulator
111 9924000035 along with adjustment of tension in stay No.
Replacement of deteriorated /providing LT
112 9924000036 dist. Box with new up to 100KVA capacity & No.
crediting it to store.
Replacement of deteriorated /providing LT
113 9924000037 dist. Box with new above 100KVA capacity & No.
crediting it to store.
114 9924000038 Adjustment of tension in stay wire No.
115 9924000039 Refitting of LA No.
Converting pin point to Shackle point
116 9924000040 location
including dismentaling & restringing etc.
replacement of 11KV Pin insulator with
providing new double pin binding
replacement of 22KV Pin insulator by new
118 9924000042 11kv pin insulator with spares & providing No.
new double pin binding
Providing 11kv double disc insulators with
binding & restringing
Replacement of existing 11kv conductor (all
size) with new double pin binding
Plumbing of PSC Pole with straightening at
Plumbing of PSC Pole with straightening at
Plumbing of tilted DP structure
123 9924000048 (PSC/RSJ/STP) with refilling of stone Murrum No.
Providing new 11kv AB /GO switch with
124 9924000049 fabrication and insulated colour code Set
jumper, binding, lugs etc
Replacement of old 11kv AB /GO switch with
125 9924000051 providing new insulated jumper, binding, Set
Providing cage type loop guard in verticle LT
126 9924000052 per pole
line with using PVC reel insulators etc
Labour charges for replacement /providing
127 9924000053 of MMB & service with all accessories for No.
three phase connection
Labour charges for replacement /providing
128 9924000054 of MMB & service with all accessories for No.
single phase connection
Dismentalling of existing Dist.X'mer
center(RSJ /STP POLE) 25/63/100/200 KVA
with all fabrication & creditig the old
material to store
130 9924000056 Disconnection from LT pole 1 phase No.
Reconnection from LT pole 1 phase
( payment after receipt of R/C charges)
132 9924000058 Disconnection from LT pole 3 phase No.
Reconnection from LT pole 3 phase
( payment after receipt of R/C charges)
Dismentaling & removing of service line
from pole & crediting to S/dn (1 ph.)
Dismentaling & removing of service line
from pole & crediting to S/dn (3 ph.)
Reconnection of service line complete with
PVC cable (1 Ph)
Reconnection of service line complete with
PVC cable (3 Ph)
Providing spiral type earthing by G.I. NO
8(weight 2kg -5mtr in length) with salt and
coal 10kg each, including pvc rigid pipe
138 9924000064 20mm dia( 1.5mtr length) to pass exposed No.
part of G.I. wire at consumer end with all
materials, earth resistance should be less
Providing and fixing of signle core 1.5 sq mm
single strand copper insulated cable with
cable nail clip for spiral type earthing at
consumer end. The end of G.I. no 8 is to be
connected by connector with copper cable
139 9924000070 of which other end shall be connected to the per meter
earth terminal of meter box. This item shall
be used in location where there is more
distance between earth terminal and
earthing terminal of meter. (All materials
supplied by contractor)
Stringing of LT ABC of 1*35 SQ MM + 1*25
SQ MM including fitting of all acessaries i.e.
special design suspension / tension clamp,
fixing of cross arm, LT shackle insulator etc.
for fixing of messenger wire and inclusive of
dismantling charge of existing bare
conductor and crediting in to store &
dismentaling of service line from LT bare
conductor and to provide service connection
on Aerial Bunch Cable by insulated pierceing
connectors through service connection box
complete as required & directed by Engineer
Stringing of LT ABC of 3*50 SQ MM +1*25
SQ MM+1*35 SQ MM including fitting of all
acessaries i.e. special design suspension /
tension clamp, fixing of cross arm, LT shackle
insulator etc. for fixing of messenger wire
and inclusive of dismantling charge of
existing bare conductor and crediting in to
store & dismentaling of service line from LT
bare conductor and to provide service
connection on Aerial Bunch Cable by
insulated pierceing connectors through
service connection box complete as
required & directed by Engineer in Charge.
Stringing of 11KV ABC of 3*95 SQ MM +80
SQ MM including fitting of all acessaries i.e.
special design suspension / tension clamp,
fixing of cross arm, binding to pin
142 9924000067 insulator,preparing shackle point,jumpers KM
etc. and inclusive of dismantling charge of
existing bare conductor and crediting in to
store complete as required & directed by
Engineer in Charge
Stringing of 22 KV ABC OF 3*70 SQ MM +95
SQ MM including fitting of all acessaries i.e.
special design suspension / tension clamp,
fixing of cross arm, binding to pin
143 9924000068 insulator,preparing shackle point,jumpers KM
etc. and inclusive of dismantling charge of
existing bare conductor and crediting in to
store complete as required & directed by
Engineer in Charge
Stringing of LT ABC of 2*50 SQ MM +1*25
SQ MM+ 35 SQ MM including fitting of all
acessaries i.e. special design suspension /
tension clamp, fixing of cross arm, LT shackle
insulator etc. for fixing of messenger wire
and inclusive of dismantling charge of
144 9924000069 existing bare conductor and crediting in to KM
store & dismentaling of service line from LT
bare conductor and to provide service
connection on Aerial Bunch Cable by
insulated pierceing connectors through
service connection box complete as required
& directed by Engineer in Charge.
Labour charge for excavation of cable trench
of 400mm width x 1200mm depth, in any
type of soil for laying of cable of size up to
240 mm2 (For additional cable 200 mm
additional width shall be considered i.e. half
trench length is to be considered)
Labour charge for excavation of cable trench
of 600mm width x 1200mm depth, in any
type of soil for laying of cable of size up to
240 mm2 (For additional cable 200 mm
additional width shall be considered i.e. half
trench length is to be considered)
Labour charge for excavation of cable trench
of 400mm width x 1500mm depth, in any
type of soil for laying of cable of size up to
240 mm2 (For additional cable 200 mm
additional width shall be considered i.e. half
trench length is to be considered)
Labour charge for laying of 11kV / 22 kV
XLPE Cable of size up to 240 mm2 &
preparation of sand layer 100mm thick, in
the cable trench & covering the cable with
150 mm dia (Inner), thickness 25 mm,
meter long RCC half round muffs and
providing and fixing of 4inch width yellow
4 9925000004 colour polyethylene tape with printing Meter
"CAUTION ELECTRIC CABLE BELOW" at
m depth from ground surface after laying
cable in trench. This will provide indication
that electric cable is passing underground so
as to protect cable from mechnical injuries,
refilling the same, as per Instruction of
Engineer in Charge (EIC).
Labour charge for horizontal drilling using
Auger machine without damage to surface
road at max 2.0 mtrs depth & putting of
kg/cm2 , class-4,Green color, 110mm O.D.
8.5mm thickness H.D.P.E. pipe confirms to IS
4984-1987(3rd revision) and BIS certification
and laying of 11KV/22KV XLPE cable of size
up to 240 mm2 in HDPE pipe, as per Site
Condition (excluding cost of pipe). The detail
map obtained from HDD machine and excell
sheet(hard and soft copy) indicating the
respective depth and distance from adjacent
landmark for each segment for HDD is must
required to be submitted. HDD to be carried
out at depth 1.5 mtrs to 2.0 mtrs as per site
conditions and as per instruction of EIC.
Labour charge for horizontal drilling
manually without damage to surface road at
max 2.0 mtrs depth & putting of
kg/cm2 , class-4,Green color, 110mm O.D.
8.5mm thickness H.D.P.E. pipe confirms to IS
4984-1987(3rd revision) and BIS certification
and laying of 11KV/22KV XLPE cable of size
6 9925000006 up to 240 mm2 size, as per Site Condition Meter
(excluding cost of pipe). The detail map and
excell sheet(hard and soft copy) indicating
the respective depth and distance from
adjacent landmark for each segment of cable
to be submitted. Drilling to be carried out at
depth Minimum 1.2 mtrs to 2.0 mtrs as per
site conditions as per instruction of EIC.
Supply of 6.11kg/cm2 , class-4,Green color,
110mm O.D. , 8.5 mm thickness H.D.P.E.
7 9925000007 pipe confirms to IS 4984 and BIS certification Meter
for laying of underground 11KV / 22KV XLPE
cable up to 240 mm2 size.
Labour work for RCC concreting on disputed
location and repairing of damage portion of
road crossing for the work carried out for
roads crossing as well as concreting &
muffing of ploes including all materials
Providing & fixing concrete stone route
marker of 300 mm width x 150 mm thick x
650 mm height embedded in earth at least
300 mm below & 350 mm above ground
level respectively at distance approx
meters along the length of cable. The RCC
concreting (1:2:4)(all necessary maeterials
will be in bidder's scope) of route marker is
to be carried out 300 mm width x 150 mm
9 9925000009 thick x 300 mm below ground level as per No.
instruction of EIC. The route marker should
be with name of company with approved
yellow colour-DGVCL. The distance from
marker to cable and cable depth with feeder
name etc., marked with arrow sign is to be
painted on it.The route marker is to be fixed
at location near to any fixed permanent
location (not necessary to fix exact on top of
cable) as per instruction of EIC.
Erection of D.P. (double pole) structure
using 9 / 11 Mtr. RSJ pole with cable
connection arrangement along with fitting of
10 9925000010 necessary fabrication for 11KV cable No.
including excavation of pit & refilling of
earth as per instruction of EIC. (Exclusive of
concreting & muffing of poles)
Erection of Single pole structure using 9 /
Mtr RSJ pole with cable connection
arrangement along with fitting ofnecessary
11 9925000011 fabrication for 11KV/22 KV cable including No.
excavation of pit & refilling of earth as per
instruction of EIC. (Exclusive of concreting &
muffing of poles)
Erection of D.P. (double pole) structure
using 8.0 Mtr. PSC pole with cable
connection arrangement along with fitting of
12 9925000012 necessary fabrication for 11KV cable No.
including excavation of pit & refilling of
earth as per instruction of EIC. (Exclusive of
concreting & muffing of poles)
Erection of Single pole structure using
Mtr PSC pole with cable connection
arrangement along with fitting ofnecessary
13 9925000013 fabrication for 11KV/22 KV cable including No.
excavation of pit & refilling of earth as per
instruction of EIC. (Exclusive of concreting &
muffing of poles)
Labour charge for erecting of 11kV / 22 kV
XLPE cable of size up to 240 mm2 on DP
Structure with fixing of 02 Nos polymer
cleats on top and middle part.Polymer
cleats, nut bolts etc. fixing material to be
provided by contractor.
Providing & fixing of 6.11kg/cm2 , class-
4,Green color, 110mm O.D. , 8.5mm
thickness H.D.P.E. pipe confirms to IS
and BIS certification on the erected DP
structure for the mechanical protection of
cable by inserting the cable inside HDPE
15 9925000015 pipe. The HDPE pipe shall be erected in such Per Job
a way that 300mm shall be below the
ground level and the rest 2700 mm shall be
supported on the DP Structure with 01 No
Polymer cleat.All materials including
polymer cleat and Nut bolt to be provided
Providing and fixing of pipe type earthing
from 80 mm dia class-B GI pipe with pit to be
filled with salt & coke and construction of
chamber as per DGVCL Drg. No. dg /100 for
DP and cable. The earthing pit should be
joined with cable by G.I. strip of size 1”
width & 2 mm thick. All material GI pipe,
Coke, Salt etc will be supplied by bidder.
Supply & fixing of heat shrink type end
terminations (outdoor) for upto 11kV 3C x
185 mm2 size XLPE cable as per DGVCL
technical specification
Supply & fixing of heat & shrinkable end
terminations (outdoor) for upto 22 kV 3C x
185 mm2 size XLPE cable as per DGVCL
technical specification)
Supply & fixing of heat shrink type end
terminations (indoor) for upto 11kV 3C x
185 mm2 size XLPE cable as per DGVCL
technical specification)
Supply & fixing of heat & shrinkable end
terminations (indoor) for upto 22 kV 3C x
185 mm2 size XLPE cable as per DGVCL
technical specification
Supply & fixing of heat shrinkable straight
through joint for upto 11kV 3C x 185 mm2
size XLPE cableas per DGVCL technical
Supply & fixing of heat shrinkable straight
through joint type for upto 22kV 3C x
mm2 size XLPE cable as per DGVCL technical
Labour charge for excavation of 2100mm
long x 1200mm wide x 1200 mm deep joint
pits for installation of 11kV / 22kV Straight
through joints as per instruction of
engineer-in-charge & covering the cable with
150 mm dia (Outer), thickness 25 mm,
meter long RCC half round muffs & refilling
same as per instruction of EIC .
Providing and fixing of insulating bus bar,
made from 11KV/22KV XLPE cable after
removal of semi conducting layer and
applying of PVC heat shrinkable anti-
tracking core insulating tubing (1.1KV), on
both end terminal using Aluminium long
barrel heavy duty up to 240 sq mm lugs,
Aluminium bus connector. Taping with PG-
clamp for bus conductor as per drawing and
as per instruction of EIC. The Alluminium
lugs and PG clamp shall be covered with
11KV/22KV HT insulating tapes.(11KV/22KV
XLPE cable will be in scope of DGVCL while
all other materials will be in bidder's scope)
Testing of cable at various points and
commissioning the feeder as per instruction
of engineer-in-charge.Test result shall be
submitted by contractor with bill.
Preparation and submission of 6 (six) copies,
of complete layout drawings with GIS
26 9925000026 mapping as per actual cable routing showing Set
road crossing, HDPE pipe sleeving, jointing
locations, markers etc.
Providing and fixing of Sign Board at junction
point Made out of 2 mm aluminium sheet
size 750x300 mm (2.5 x 1ft) rectangle, as per
design, pre treated with phosphate process
and acid etching coated with one coat of
epoxy primer and two coats of best quality
paints, refloctrorised with Hi-Intensity retro
– reflective sheeting as per the latest and
27 9925000027 frame fabricated from suitable size iron No.
angle. The Sign Board is to be fixed on the
base prepared from channel and bracing
angles which is grouted by means of cement
concreting of 1:2:4 for size of 300 mm dia x
800 mm height (500 mm to be grouted in
ground). The details to be displayed on sign
board will be given by In-charge Engineer.
(a) Hi intensity Micro prismatic Grade
Providing and fixing of Sign Board (Danger
Board) on Distribution Transformer Centers
Made out of 2mm aluminium sheet size
300x300mm (1x1ft) as per design, pre
treated with phosphate process and acid
etching coated with one coat of epoxy
primer and two coats of best quality paints,
refloctrorised with Hi-Intensity retro-
reflective sheeting as per the latest and
frame fabricated from suitable size iron
angle. The Sign Board (Danger Board is to be
fixed at the location as per instruction of In-
charge Engineer.
(a) Hi intensity Micro prismatic Grade
Providing & fixing of aluminium tag of size
250 mm (L) x 75 mm (W) from 3 mm
aluminium sheet along with 1.0 mm dia
aluminium binding wire for fixing of
aluminium tag near end termination joint at
DP structure for identifyng the cable. The
details of feeder i.e. 11 / 22 KV with feeder
name shound be punched on the tag by
letter punch of size 16 mm as per instruction
of In-charge Engineer.
Supply & fixing of heat shrink type end
terminations (outdoor) for 11kV 3C x
mm2 size XLPE cable as per DGVCL technical
Supply & fixing of heat & shrinkable end
terminations (outdoor) for 22 kV 3C x
mm2 size XLPE cable as per DGVCL technical
Supply & fixing of heat shrink type end
terminations (indoor) for 11kV 3C x
mm2 size XLPE cable as per DGVCL technical
Supply & fixing of heat & shrinkable end
terminations (indoor) for 22 kV 3C x
mm2 size XLPE cable as per DGVCL technical
Supply & fixing of heat shrinkable straight
through joint for 11kV 3C x 240 mm2 size
XLPE cableas per DGVCL technical
Supply & fixing of heat shrinkable straight
through joint type for 22kV 3C x 240 mm2
size XLPE cable as per DGVCL technical
Installation, Testing and commissioning of
11 KV,630 A SCADA Compatible, RRL type-
Way RMU including Two numbers of
earthings as per Drawing (material is in
bidder's scope) and as per DGVCL Technical
Installation, Testing and commissioning of
11 KV,630 A SCADA Compatible, RRLL type-
4 Way RMU including Two numbers of
earthings as per Drawing (material is in
bidder's scope) and as per DGVCL Technical
Installation, Testing and commissioning of
22KV,630 A SCADA Compatible, RRL type-3
Way, RMU including Two numbers of
earthings as per Drawing (material is in
bidder's scope) and as per DGVCL Technical
Installation, Testing and commissioning of
22KV,630 A SCADA Compatible, RRLL type-4
Way, RMU including Two numbers of
earthings as per Drawing (material is in
bidder's scope) and as per DGVCL Technical
Construction of plinth for 11KV, RRL type-
Way (i.e Two numbers of Isolator & One
number of Breaker) Ring Main Unit as per
DGVCL's technical specification mentioned in
drawing no: Drg. 11kv-01. All required
material will be supplied by contractor.
Construction of plinth for 11KV, RRLL type-
4 Way (i.e Two numbers of Isolator & Two
number of Breaker)Ring Main Unit as per
DGVCL's technical specification mentioned in
drawing no:Drg. 11kv-02.All required
material will be supplied by contractor.
Construction of plinth for 22KV, RRL type-
Way (i.e Two numbers of Isolator & One
number of Breaker) Ring Main Unit as per
DGVCL's technical specification mentioned in
drawing no: Drg. 22kv-01. All required
material will be supplied by contractor.
Construction of plinth for 22KV, RRLL type-
4 Way (i.e Two numbers of Isolator & Two
number of Breaker)Ring Main Unit as per
DGVCL's technical specification mentioned in
drawing no:Drg. 22kv-02.All required
material will be supplied by contractor.
Modifications e.g.Providing and fixing of
Terminal protectors i.e. Re-use able boot (HT
Side 11/22KV, LT Side 1.1KV) including 11/22
KV insulating taps and L.T.(1.1 KV) insulating
taps ,Busbar, Tapping from Bus Bar (11/22
KV XLPE cable) through P.G. Clamp for H.T.
Jumper to D.O. Fuse to bushings of
Transformer Center, providing & Fixing of
jumper and providing & fixing of Heat
Shrinkable Anti Tracking Core Insulating
Tubing (Insulation Level 11/22 KV) in H.T.
jumper , Clamping arrangement of cable
support frame on both side of existing Over
Head type Distribution Transformer to
utilize in Under Ground cable network as per
drawing & as per instruction of Engineer
incharge. All live parts i.e. PG-Clamp,
connections of D.O.fuses, HT bushings etc .
shall be covered with fixinng of 11/22 KV HT
insulating tapes. ( 11/22 KV XLPE cable will
be in scope of DGVCL while all other
materials will be in bidder's scope ) .
Laying of any size of 11/ 22 KV XLPE /PILC
45 9925000047 Per Cable Per Mtr
Cable in redaymade trench or in open space
Labour charges for Lying of O/H XLPE cable
Supply of 150 mm dia (Inner), thickness
mm, 1.0 meter long RCC half round pipe
Laying,Testing & commissioning of Specially
designed 11 KV 55 mm2
AAAC Medium Voltage Covered conductor as per
specifications (with accessories)
Laying,Testing & commissioning of Specially
designed 11 KV AL-59
ACS Medium Voltage Covered conductor as per the
specifications (with accessories)
CARTING OF PSC POLE AT SITE PER POLE
CARTING OF RSJ POLE AT SITE PER POLE
1.DGVCL will provide key material like M.S.
materials,ABC/Bare conductors,PSC/RSJ
Poles,Insulators,Fabricated materials etc.
to the contractor.2.All fabricated items shall
be fabricated as per DGVCL approved
drawing and by welding rods confirming to
the relevent ISI specification and as
directed by Engineer in charge.3.Necessary
electricity connection for fabrication items
shall be provided by DGVCL on payment of
required charge for connection & electricity
bill of the same shall be paid by the
agency.4.All the rates are inclusive of PF &
Exclusive of GST applicable time to time.5.All
steel material are to be painted as below:(a)
Scrubbing of rusted surface properly before
applying the paints on to the RSJ poles &
steel fabricated materials of RSJ/PSC poles is
must required.(b) Two coats of approved ISI
mark red oxide (primer) is to be properly
painted for the RSJ poles & steel fabricated
materials of RSJ/PSC poles. (c) Two coats of
approved ISI mark silver paint (i.e. triple
mangoes or equivalent quality silver paint) is
to be properly painted on to the RSJ poles &
steel fabricated materials of RSJ/PSC poles.
EXECUTIVE ENGINEERING (O&M)