Loading…
Loading…
Tender Value
₹7.2 L
EMD Value
₹17,924
Closing Date
8 Oct 2026, 3:00 pm6d left
ASSISTANT EXECUTIVE ENGINEER
Office of the Assistant Executive Engineer, LSGD SUB DIVISION PAMPAKUDA BLOCK
SC Corpus Fund-SC DEVELOPMENT AISWARYA GRAMAM PADHATHY 2025- 2 6 P A M P A K U D A B L O C K - IDAMANAKKUNNU NAGAR IN PALAKUZHA GP-General Civil Work
2026_LSGD_875108_1
2/AEE/2026-27
Open Tender
Civil Works - Others
Item Rate
360 days
Pampakuda
Please refer Tender documents.
7 documents required · 7 mandatory
₹1,585
Yes
₹17,924
Yes
30 Sept 2026
30 Sept 2026
9 Oct 2026
30 Sept 2026
8 Oct 2026
30 Sept 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1Kudivella padhathy | |||||
| 1.001 | 13.16.1:6 mm cement plaster of mix:1:3 ( 1 cement : 3 fine sand) | 48.8 | sqm | - | - |
| 1.002 | 13.7.2:12 mm cement plaster finished with a floating coat of neat cement of mix:1:4 ( 1 cement : 4 fine sand) | 30.92 | sqm | - | - |
| 1.003 | 13.21:Extra for providing and mixing water proofing material in cement plaster work in proportion recommended by the manufacturers. | 18 | bag | - | - |
| 1.004 | 13.60.1:Wall painting with acrylic emulsion paint of approved brand and manufacture to give an even shade:Two or more coats on new work | 30.92 | sqm | - | - |
| 1.005 | 22.23.2:Providing and applying integral crystalline slurry of hydrophilic in nature for
waterproofing treatment to the RCC structures like retaining walls of the basement,
water tanks, roof slabs, podiums, reservior, sewage & water treatment plant, tunnels
/ subway and bridge deck etc., prepared by mixing in the ratio of 5 : 2 (5 parts
integral crystalline slurry : 2 parts water) for vertical surfaces and 3 : 1 (3 parts
integral crystalline slurry : 1 part water) for horizontal surfaces and applying the
same from negative (internal) side with the help of synthetic fiber brush. The material
shall meet the requirements as specified in ACI-212-3R-2010 i.e by reducing
permeability of concrete by more than 90% compared with control concrete as per
DIN 1048 and resistant to 16 bar hydrostatic pressure on negative side. The crystalline
slurry shall be capable of self-healing of cracks up to a width of 0.50mm. The work
shall be carried out all complete as per specification and the direction of the engineerin-
charge. The product performance shall carry guarantee for 10 years against any
leakage.For horizontal surface one coat @1.10 kg per sqm. | 8.12 | sqm | - | - |
| 1.006 | 11.41A.1.1: Providing and laying Vitrified tiles in floor in different sizes (thickness to be
specified by the manufacturer) with water absorption less than 0.08% and
conforming to IS:15622, of approved brand & manufacturer, in all colours and
shade, laid on 20 mm thick cement mortar 1:4 (1 cement: 4 coarse sand) jointing
with grey cement slurry @3.3 kg/sqm including grouting the joints with white
cement and matching pigments etc. The tiles must be cut with the zero chipping
diamond cutter only . Laying of tiles will be done with the notch trowel, plier,
wedge, clips of required thickness, leveling system and rubber mallet for placing
the tiles gently and easily.
Double charge vitrified tile polished finish of size
Size of Tile 600 x 600 mm | 8.12 | sqm | - | - |
| 1.007 | 5.33.2.1:Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana / Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge; for the following grades of concrete. Note: Extra cement up to 10% of the minimum specified cement content in design mix shall be payable separately. In case the cement content in design mix is more than 110% of the specified minimum cement content, the contractor shall have discretion to either re-design the mix or bear the cost of extra cement
All work above plinth level upto floor V levelConcrete of M25 grade with minimum cement content of 330 kg /cum | 2 | cum | - | - |
| 1.008 | 5.9.3:Centering and shuttering including strutting, etc. and removal of form for:Suspended floors, roofs, landings, balconies and access platform | 15.08 | sqm | - | - |
| 1.009 | 5.22.6:Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth levelThermo - Mechanically Treated bars of grade Fe-500D or more | 159.87 | kilogram | - | - |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.05 MB
BOQ_1485632.xls
BOQ • 0.32 MB
viewnit.pdf
Tender Documents • 0.03 MB
viewsbdaisw.pdf
Tender Documents • 1.72 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .