Loading…
India Infra Updates on WhatsApp
Join the Tenderkart WhatsApp channel for India Infra Updates
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹21.8 LAccepted-AOC 16 1 A GANGADHAR SEN LANE KOLKATA 700036 | KOLKATA | KOLKATA | WEST BENGAL | 700036 | L1 | Accepted-AOC L1 | |
| 2 | L2₹22.7 L+₹30,000 (1.34%)Rejected-Finance | L2 | Rejected-Finance Reject | |
| 3 | L3₹22.8 L+₹40,000 (1.79%)Rejected-Finance | L3 | Rejected-Finance REject |
Tender Value
Refer Docs
EMD Value
₹43,622
Closing Date
13 Jul 2024, 5:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Chairman, Dalkhola Municipality
Chairman, Dalkhola Municipality, Dalkhola Uttar Dinajpur.
SUPPLY FITTINGS and LAYING RESTORATION OF DI (K7) PIPES IN DISTRIBUTION SYSTEM ZONE I Partly UNDER DALKHOLA MUNICIPALITY
2024_MAD_701762_1
WBMAD/CM/DLK/NIQ-1(e)/24-25
Open Tender
CIVIL WORKS
Item Rate
60 days
Within Dalkhola Municipality
Please refer Tender documents.
4 documents required · 4 mandatory
₹0
₹43,622
28 Aug 2024
28 Jun 2024
15 Jul 2024
28 Jun 2024
13 Jul 2024
28 Jun 2024
Amount
Carrying CI/DI pipes with specials and valves and lowering placing in position and laying carefully inside the trenches in proper alignment and gradient etc. including earth work in excavation of adequate width as per specification having min. clear cover from top of pipe is 1.10mtr. below existing ground level in any kind of soil including mixed with boulder, road sub-grade and its flank,but excluding moorum and laterite and stone etc.without damaging the exisiting telephone/ electric cable etc. (in case of damaged if any type of cable line during excecution, necessary damaged charges as applicable by the respective authority will be borne by the agency in his own cost) preparing the bottom surface for continuous bedding of pipe line and laying pipes, fitting, fixing specials and valves with bailing out water if any including carriage of pipes, specials and valves from local deptt. store within 8KM and back filling the trenches with excavated earth in layers to original condition as per specification and direction of EIC. The surplus materials after execution of work are to be return to the deptt. store. N.B: i) Any deviation from required clear cover of 1.10mtr., due to site adverse condition, prior permission is to be obtained from the EIC in exceptional situation and payment will be made on prorate basis over the rate of entire item ii) No payment will be made without hydraulic test of the pipe line either part or full
100 mm dia. D.I. pipe
150 mm dia. D.I. pipe
250 mm dia. D.I. pipe
350 mm dia. D.I. pipe
Making rubber gasket joint to CI/DI pipes maintaining proper alignment level etc. by mechanical arrangement with or without using mobile cranes where necessary and with help of all other equipments tools and tackles etc. as required providing lubricants of approved quality and direction of EIC. (rubber gasket will be supplied deptt. free of cost) 100 mm dia. D.I. pipe
150 mm dia. D.I. pipe
250 mm dia. D.I. pipe
350 mm dia. D.I. pipe
Making flange joint to DI/CI pipes, specials and valves where necessary with supply of required rubber insertion and nut bolts, washers etc. of approved quality and type all complete as per specification and direction of EIC (Nut and bolts shall be of TATA/GKW rate). 100 mm dia. D.I. pipe
150 mm dia. D.I. pipe
250 mm dia. D.I. pipe
350 mm dia. D.I. pipe
Cutting DI pipe (all class & type) to required length with cutting device etc. and grinding the cutting portion with file as per direction and satisfaction of EIC 100 mm dia. D.I. pipe
150 mm dia. D.I. pipe
250 mm dia. D.I. pipe
350 mm dia. D.I. pipe
Chamfering the spigot end of all type/class of DI pipe for proper using of push joint by means of grinder set at site for proper joint etc. all complete [ PHE SOR, Page L-17, Item No. 08(e) to 08(i) ] 100 mm dia. D.I. pipe
150 mm dia. D.I. pipe
250 mm dia. D.I. pipe
350 mm dia. D.I. pipe
Filling the pipe line with water, testing hydraulically as per I.S 3114-1965 (Article-6)in section of a length not exceeding 500mtr. for head of pressure as per specification including supplying installing and fixing all equipments such as dieselpump set, blank flange, pressure gauge, valve, pressure pump and all other tools and plants including drilling topping and plugging of necessary holes to pipes, blocking ends providing temporary thrust block and subsequent blocking of holes and other jointing materials and dismantling and removal of the same including disposal of water etc. all complete as per specification and direction of EIC. The rate is inclusive of cost of requisite water to be arranged by the contractor (Recovery rate of water @ Rs.10.00/m3, if contractor used water from deptt. source). For CI/DI pipe [ PHE SOR, Page L-18, Item No. 09.A.(e) to 09.A.(i) ] 100 mm dia. D.I. pipe
150 mm dia. D.I. pipe
200 mm dia. D.I. pipe
250 mm dia. D.I. pipe
350 mm dia. D.I. pipe
Cleaning thoroughly the inner surface of pipe line including specials and valves by flushing with water and subsequently disinfection of the same pipe line by flushing again with water containing bleaching powder resulting in residual chlorine not less than 15mg/ltrs. after 24hrs. of such filling including laboratory testing of water samples obtain from the disinfested pipe line and disposal of water from the pipe line after completion of the work. The rates including of cost of requisite water to be arranged by the contractor (The rate of water @Rs. 10/m3 may be recovered, if the contractor used water from deptt. source). For CI/DI pipe [ PHE SOR, Page L-19 & L-20, Item No. 10.A.(e) to 10.A.(i) ] 100 mm dia. D.I. pipe
150 mm dia. D.I. pipe
200 mm dia. D.I. pipe
250 mm dia. D.I. pipe
350 mm dia. D.I. pipe
Submission of complete detailed drawing of distribution system, rising main etc. after execution of work showing position of different types of valves, fittings/specials sluice valve chamber with location, node to node wise in the sanctioned drawing as completion drawing of the water supply scheme as per direction and satisfaction of EIC. The list of dia wise fitting/specials, different pipes ;of valve used in the rising main should be shown in the completion drawing (not separate) with verified by SAE & AE incharge of the scheme. The above drawing will be submitted in 5 copies. [ PHE SOR, Page L-19 & L-20, Item No. 10.A.(e) to 10.A.(i) ]
Cutting & picking up existing metalled black top portion of road surface to an average depth of 300 mm by using Jack hammer with all necessary tool and plant including reening the serviceable materials & stacking within a lead of 75 mtr. all complete as per direction of the Engineer-in- Charge. [ UDMA SOR, Page 2, Item No. 1.5 ]
Dismantling all type of plain cement concrete works, stacking serviceable materials of site and removing rubbish as directed within a lead of 75mtr. for laying all dia pipe line in ground floor, upto 150mm thick. [ PWD SOR, Vol-I, Page 10, Item 2(a) ]
Construction of different dia Sluice valve/Air valve/Washout chamber in different sizes for village road where light traffic run and for main road where heavy traffic run as deptt.approved drawing with 25cm thick brick work (1:6) over cement concrete (4:2:1) over a single B/F soling over150mm.thick sand filling in foundation including earth work in excavation and disposal of excess earth from work site with RCC (1:1.5:3) cover slab 100mm / 150mm thick slab on top of chamber with 1% reinforcement in RCC cover slab with necessary opening for operation of valve all complete including cost of labour & materials as per Departmental Dwg. [Reinforcement type:- Other manufactuerers not specified] [ PHE SOR, Page L-21 & L-22, Item No. 14(ii) to 14(iv) ] 100 mm dia. D.I. pipe
150 mm dia. D.I. pipe
200 mm dia. D.I. pipe
250 mm dia. D.I. pipe
350 mm dia. D.I. pipe
Cast iron double flanged Non-Rising Spindle Sluice Valve generally confirming to IS 14846 having body door/dome/Bonnet and cover of cast Iron Gr FG 260, Spindle of IS 6603, Gr-12 cr-13, spindle nut & seat rings are of Gunmetal as per IS:318 LTB 2. Flanges flat faced and drilled to IS:1538 Part IV & VI, Valves are suitable for maximum working pressure of 10 kg/sqcm (seat test) and body tested to 15 kg/sqcm 350 NB and above valves should be provided with enclosed gear box and antifriction device for ease of operation. All the valves should be tested by closed end method only. [ PHE SOR, Page D-3 ] 100 mm dia. D.I. pipe
150 mm dia. D.I. pipe
200 mm dia. D.I. pipe
250 mm dia. D.I. pipe
350 mm dia. D.I. pipe
All Types of D.I a) All Socket Tee 100 mm dia. To 300 mm dia. 100 mm dia (8 x 13.8)+ 110.4 kg 150 mm dia (8 x 19.5) = 156 kg 250 mm dia(12 48.0) + (0 x 45.0 ) + (0x36.0) = 576 kg 300 mm dia (2 x 62.0) + (1 + 49.0) = 173 kg.
(ii) b) double socketed bend 100 mm dia. To 300 mm dia. 100 mm dia. (30 x 9.2) + (30 x 7.9) + (30 x 7.3) = 732 kg 150mm dia. (25 x 16.8) + (25 x 13.5) + (25 x 12.0) = 1057.5 Total = 1789.5 kg
c) Tail piece 100 mm dia. To 300 mm dia. 200 mm dia.(2 x 19.7) + (2 x 22.5) = kg 250 mm dia. (2 x 27.5) + ( 2 x 31.5) = kg Total = 202.4 kg
Box cutting or filling in Road embankment in all sorts of soil including spreading the spoils properly over the flank as necessary or on berm to approximate grade & camber and rolling the sub-grade with power roller to proper camber and grade as per direction and satisfaction of Engineer-in-charge including uprooting and removing plants and jungles when and where necessary. [ SOR-III, Page 237, Item 3.16(a) ] For Distribution: 100 mm dia. D.I. pipe ( 260 x 0.4) = 104 For Distribution: 150 mm dia. D.I. pipe ( 300 x 0.45) = 135 For Distribution: 250 mm dia. D.I. pipe( 450 x 0.55) = 247.5 For Distribution: 350 mm dia. D.I. pipe (61 x 0..65) = 39.65
Single brick flat soling of picked jhama bricks including ramming and dressing bed to proper level and filling joints with local sand. For Distribution: 150 mm dia. D.I. pipe ( 300 x 0.45) = 135 For Distribution: 250 mm dia. D.I. pipe( 450 x 0.55) = 247.5 For Distribution: 350 mm dia. D.I. pipe(61 x 0..65) = 39.65
stone chips (20 mm nominal size) excluding shuttering and reinforcement if any, in ground floor as per relevant IS codes. Pakur Variety [ Analysed Rate ] For Distribution: 100 mm dia. D.I. pipe ( 260 x 0.4 x 0.125) = 13.0 For Distribution: 150 mm dia. D.I. pipe ( 300 x 0.45 x 0.125) = 16.87 For Distribution: 250 mm dia. D.I. pipe( 450 x 0.55 x 0.125) = 30.93 For Distribution: 350 mm dia. D.I. pipe(61 x 0..65 x 0.125) = 4.95
YOUNG ENGINEERS CO OPERATIVE SOCIETY LIMITED
SETH ENTERPRISE
tech_bid_open.pdf
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .