| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹23.7 LAccepted-AOC POST BINNAGURI DIST JALPAIGURI W B PIN 735 203 | JALPAIGURI | WEST BENGAL | 735203 | L1 | Accepted-AOC LOWEST BIDDER | |
| 2 | L2₹25.1 L+₹41,674.90 (1.69%)Rejected-Finance | L2 | Rejected-Finance OTHER THEN LOWEST BIDDER | |
| 3 | L3₹25.7 L+₹98,245.60 (3.97%)Rejected-Finance | L3 | Rejected-Finance OTHER THEN LOWEST BIDDER | |
| 4 | L4₹26.9 L+₹2.2 L (8.89%)Rejected-Finance DEPOPARA PO BINNAGURI PS BANARHAT DIST JALPAIGURI WEST BENGAL PIN 735 203 | JALPAIGURI | WEST BENGAL | 735203 | L4 | Rejected-Finance OTHER THEN LOWEST BIDDER | |
| 5 | L5₹29.9 L+₹5.2 L (20.9%)Rejected-Finance PO BINNAGURI DIST JALPAIGURI PIN 735203 W B | JALPAIGURI | WEST BENGAL | 735203 | L5 | Rejected-Finance OTHER THEN LOWEST BIDDER |
Tender Value
₹34 L
EMD Value
₹68,000
Closing Date
6 Aug 2021, 6:00 pmClosed
GE (SOUTH) BINNAGURI
GE (SOUTH) BINNAGURI, PO - BINNAGURI, DISTT - JALPAIGURI, PIN - 735232
SPECIAL REPAIR OF INTERNAL, EXTERNAL ELECTRIFICATION OF KV STAFF QTRS AND REPLACEMENT OF OLD GI PIPE LINE AT NORTH AND CENTRAL ZONE UNDER GE (S) BINNAGURI
2021_MES_456362_1
8433/E8
Open Tender
Civil Works
Item Rate
180 days
GE (SOUTH) BINNAGURI
AS PER TENDER DOCUMENTS
7 documents required · 7 mandatory
₹500
GE (SOUTH) BINNAGURI
₹68,000
Yes
21 Oct 2021
1 Jul 2021
7 Aug 2021
1 Jul 2021
6 Aug 2021
16 Jul 2021
Amount
Taking down carefully aluminium conductor point wiring (light,fan,socket or power) complete including fittings such as switches,ceiling roses, pendants, regulators ,sockets etc. and removing (except those to be reused shall be kept in safe custody at the site ) and making good disturbed surfaces of walls, floors etc.to match with the existing complete all as specified.
M&L point wiring complete with FRLS PVC insulated unsheathed multistranded copper conductor of size 1.50 sqmm nominal cross sectional area single core drawn in and including 25mm PVC casing caping and fittings, MS terminal concealed boxes, 3mm thick plastic laminated sheet top cover (ISI Marked) fitted with chromium plated brass screws & washers complete including 1.50 sqmm nominal cross sectional area PVC insulated unsheathed multistranded copper conductor green as earth wire connected to earth dolly with all accessories including making good disturbed surfaces with CM(1:4) with treating the surfaces as per existing finishes for following complete all as specified and directed.
(a) One light point controlled by one way switch 5/6 amps.
(b) One ceiling fan/Exhaut fan point controlled by one way switch 5/6 amps.
(c) One socket out let 5/6 amps point on the same board
(d) One socket out let 5/6 amps point on the independent board
(e) One bell/buzzer point controlled by one bell push button
(f) One light point controlled by two way switch 5/6 amps
M&L for point wiring complete for one socket outlet 15 amps point on independent board with 2.5 sqm multistranded copper conductor single core PVC insulated unsheathed FRLS cable 1100 volt grade (ISI marked) with proper colour coding drawn through and including non-metallic rigid PVC medium grade conduit not less than 20 mm dia and conduit accessories(ISI marked) concealed in wall/fixed to roof, ceiling etc including provision of 2.5 sqm PVC insulated multistranded unsheathed copper conductor cable FRLS (ISI marked) as earth continuity conductor connected to common earth dolly, fabricated sunken terminal box made out oof GI steel sheet not less than 1.2mm thick for boxes upto a size of 200x300mm and about this size not less than 1.63mm thick duly painted with aluminium inside and anti corrosive paint outside, consealed in wall, with 3 mm thick backelite/plastic laminated sheet top cover fixed with cadmium plated iron screw for housing switches, socjket outlet, dfan regulator etc duly earthed including cutting chaces of existing wall for conduits and sinking for boxes and making good to the disturbed surfaces of wall/floor and matching with existing specification. Connection of cable with MCBs or bus bar shall be done through proper size copper/brass timbles complete all as specified and directed.
M&L for point wiring complete for one power point for one metal plug & socket for AC or one socket for gyser point on independent board with 4.0 sqm multistranded copper conductor single core PVC insulated unsheathed FRLS cable 1100 volt grade (ISI marked) with proper colour coding drawn through and including non-metallic rigid PVC medium grade conduit not less than 20 mm dia and conduit accessories(ISI marked) concealed in wall/fixed to roof, ceiling etc including provision of 4.0 sqm PVC insulated multistranded unsheathed copper conductor cable FRLS (ISI marked) as earth continuity conductor connected to common earth dolly, fabricated sunken terminal box made out oof GI steel sheet not less than 1.2mm thick for boxes upto a size of 200x300mm and about this size not less than 1.63mm thick duly painted with aluminium inside and anti corrosive paint outside, consealed in wall, with 3 mm thick backelite/plastic laminated sheet top cover fixed with cadmium plated iron screw for housing switches, socjket outlet, dfan regulator etc duly earthed including cutting chaces of existing wall for conduits and sinking for boxes and making good to the disturbed surfaces of wall/floor and matching with existing specification. Connection of cable with MCBs or bus bar shall be done through proper size copper/brass timbles complete all as specified and directed.
S&F in repair of socket outlet 2 in 1, 5 Pin 5/6 Amp multipurpose 230 volt flush type complete all as specified and directed by Engr-in-Charge.
S&F in repair of socket outlet 2 in 1, 5 Pin 5/15 Amp multipurpose 230 volt flush type complete all as specified and directed by Engr-in-Charge.
S&F in repair switch piano flush type 5/6 amps single pole one way complete all as specified and directed.
S&F in repair bell/buzzer push type 5/6 amps single pole one way complete all as specified and directed.
S&F in repair 2 way switch piano flush type 5/6 amps single pole one way complete all as specified and directed.
S&F in repair switch piano flush type 15/16 amps single pole one way complete all as specified and directed.
S&F in repair call bell ding dong type 5/6 amps single pole one way complete all as specified and directed.
S&F in repair ceiling rose, bakelite, surface type, 220/240 volts, three terminals complete all as specified and directed.
S&F in repair Lamp holder, insulated body, with back plate suitable for batten/angle fitting complete all as specified and directed.
S & F in repair deluxe fan Electronic regulator AC 50 Hzs rotary step white/ivory finish complete all as specified and directed.
S&F in repair surface & wall mounted 18 watt LED batten light fittings including LED tube with extruded Aluminium housing complete with constant current electronc driver all accessories including provision of three core PVC cable of copper conductor and making connection complete all as specified and directed.
S&F in repair surface & wall mounted 10 watt LED batten light fittings including LED tube with extruded Aluminium housing complete with constant current electronc driver all accessories including provision of three core PVC cable of copper conductor and making connection complete all as specified and directed.
S&F in repair LED Mirror light fitting 1x10W with LED tube with all accessary including connection with twin core twisted flexible copper conductor cable of suitable size complete all as specified and directed.
S&F in repair decorative wall light fixture made up of polycarbonate suitable for 1x10 watt light having B-22 base lamp holder complete all as specified and directed.
M&L in repair for two single core (submain) PVC insulated cable with 6 sqmm nominal cross sectional area stranded copper conductor and one single core green PVC insulated 6 sqmm stranded copper conductor earth continuity cable drawn through non metallic, medium duty, rigid PVC conduit not less than 32 mm dia concealed in wall including all conduit and fixing accessories including cutting chases & making disturbed surfaces complete all as directed. Note :- (I) The cost for cutting, chases required shall deemed to be included in the quoted unit rate. (II) Two run of submain wire, one run of earth wire and one run of PVC conduit shall be measured one RM
Supply and Fixing in repair MCB DB double door, powder coated sheet metal enclosure, 4 way 240 volts grade triple pole and neutral with 200 amps rated bus bar, fixed to wall using nuts & bolts and washer of suitable dia and grouted to wall using suitable gutties complete all as specified and as directed.
Supply and Fixing in repair MCB DB double door, powder coated sheet metal enclosure, 8 way 240 volts grade single pole and neutral with 100 amps rated bus bar, fixed to wall using nuts & bolts and washer of suitable dia and grouted to wall using suitable gutties complete all as specified and as directed.
S&F in repair MCB tripple pole & neutral 63 amp, 415 volts, 'C' series, 10 KA breaking capacity & making connection complete all as specified and directed.
S&F in repair MCB single pole & neutral 6 to 32 amps, 240 volts, 'C' series, 10 KA breaking capacity & making connection complete all as specified and directed.
S&F in repair MCB single pole, 6 to 32 amps rating, 240 volts, 'C' series, 10 KA breaking capacity & making connection complete all as specified and directed.
S&F in repair exhaust fan of 300mm sweep A/C single phase 230/240 volts heavy duty complete with fan motor, blade, bracket and ring including cutting holes in eisting wall, grouting anchor bolts and making good to disturbed surfaces to match the existing complete including provision of PVC insulated & PVC sheathed round flexible cable of copper conductor,Three core of size 0.5 sqmm from ceiling rose to connector of fan all as specified and directed.
M&L in replacement for Earthing complete with galvanised steel plate electrode of size 600x600x6.30mm thick burried directly in ground with earth pit not less than 2.25 meter deep below normal ground level with top edge of plate not less than 1.5 meter below normal ground level connected to galvanised iron strip 25x4 mm thick as earth lead by means of nuts bolts check nuts GI washers earth wire protected by galvanised iron pipe 15mm bore (Light grade) for building LT wall panel all as directed including concrete pit in PCC (1:3:6) type CI, precast RCC cover slab of size 30x30x10 cm with one handle for lifting made out of 8 mm diameter MS bar finnel wire mesh 20 mm bore galvanised iron pipe (medium grade) for watering charcoal or coke and salt in alternate layers necessary earth work in soft/loose soilwith and including taking down the old one complete all as shown in electrical plate No 3 of SSR Part I 2009 including testing on complete all as specified and directed
Supply ,installation, testing and commissionning of electric water heater, storage vertical type ,BEE 5 star rated 25 ltr capacity 230 vlts AC, 50 Hz comprising of high wattage heating element for instant heating, Extra thick SS inner tank of superior 304 grade rust & shock proof ABS outer body, non ferrous pressure plate with and including provision of 04 Nos grouting bolts suitably flushed to wall or any other surface including electric connection with 03 core PVC insulated, sheathed, stranded copper conductor cable complete all as specifieed and as directed.
M&L for GI water tubing medium grade 15 mm dia. Fixed on wall with all fitting complete all as specifieed and as directed.
S&F of angle stop valve with wall flange, chromium plated screw down of size 15 mm fancy type complete all as specifieed and as directed.
S&F of bib tape fancy type, chromium plated screw down of size 15 mm fancy type complete all as specifieed and as directed.
S&F hot and cold water connection pipe of required size for water heater complete all as specifieed and as directed.
S&F in repair PVC Insulated screened XLPE Insulated screened PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 16 sqmm 4 core , providing lugs, straight through joints as required complete including jointing material as required and making connection of LT cables , including dismantling & taking out defective LT under ground PVC cable from trenches, cutting and removing defective parts complete all as specified and directed.:- Note:- Excavation & earthwork,sand cushoining,brick protection & GI pipe shall measured and paid separately,
Excavation in trenches not exc 1.5 Mtr wide and n.exc 1.5 mtr in depth, getting out for electric cable complete in any type of soil complete all as specified and directed
Returning, filling in, soil obtained from excavation including spreading, levelling and well ramming in layers n.exc 25cm thick complete all as specified and directed
Removing surplus excavated soil to a distance n.exc 50 mtr and depositing where directed at a level n. exc 1.5 mtr above starting point complete all as specified and directed
M & L for sand cushioning with river Sand to underground cable (8 cm thick before laying and 15 cm thick after laying the cable punned to a thickness of 18 cm) complete all as specified and directed
Supply and laying sub class 'B' bricks laid dry and flat across the length of cable for protection of cable complete all as specified and directed
S&F 40mm dia GI tubing medium grade ISI marked laid in tranches/floor for protection of cable including all fitting such as elbow, bends etc. complete all as specified and directed.
Taking up or down steel water tubing and necessary connection complete all as directed by Engr-in-Charge for 15 mm bore pipe, complete all as specified and as directed.
Taking up or down steel water tubing and necessary connection complete all as directed by Engr-in-Charge for 20 mm bore pipe, complete all as specified and as directed.
Taking up or down steel water tubing and necessary connection complete all as directed by Engr-in-Charge for 25 mm bore pipe, complete all as specified and as directed.
Taking up or down steel water tubing and necessary connection complete all as directed by Engr-in-Charge for 40 mm bore pipe, complete all as specified and as directed.
Taking up or down steel water tubing and necessary connection complete all as directed by Engr-in-Charge for 50 mm bore pipe, complete all as specified and as directed.
S&F Galvanised iron tube, medium grade, with all fittings and laid in trenches complete all as specified and directed for 15 mm bore pipe, complete all as specified and as directed.
S&F Galvanised iron tube, medium grade, with all fittings and laid in trenches complete all as specified and directed for 20 mm bore pipe, complete all as specified and as directed.
S&F Galvanised iron tube, medium grade, with all fittings and laid in trenches complete all as specified and directed for 25 mm bore pipe, complete all as specified and as directed.
S&F Galvanised iron tube, medium grade, with all fittings and laid in trenches complete all as specified and directed for 40 mm bore pipe, complete all as specified and as directed.
S&F Galvanised iron tube, medium grade, with all fittings and laid in trenches complete all as specified and directed for 50 mm bore pipe, complete all as specified and as directed.
S&F Galvanised iron tube, medium grade, laying on wall/floor/ceiling with all fittings complete all as specified and directed for 15 mm bore pipe, complete all as specified and as directed.
S&F Galvanised iron tube, medium grade, laying on wall/floor/ceiling with all fittings complete all as specified and directed for 20 mm bore pipe, complete all as specified and as directed.
S&F Galvanised iron tube, medium grade, laying on wall/floor/ceiling with all fittings complete all as specified and directed for 25 mm bore pipe, complete all as specified and as directed.
S&F Galvanised iron tube, medium grade, laying on wall/floor/ceiling with all fittings complete all as specified and directed for 40 mm bore pipe, complete all as specified and as directed.
S&F Galvanised iron tube, medium grade, laying on wall/floor/ceiling with all fittings complete all as specified and directed for 50 mm bore pipe, complete all as specified and as directed.
S&F Gun matel gate valve with iron wheel head screwed both ends for iron pipe for 50 mm bore, complete all as specified and as directed.
S&F Gun matel gate valve with iron wheel head screwed both ends for iron pipe for 40 mm bore, complete all as specified and as directed.
S&F Gun matel gate valve with iron wheel head screwed both ends for iron pipe for 25 mm bore, complete all as specified and as directed.
S&F Gun matel gate valve with iron wheel head screwed both ends for iron pipe for 20 mm bore, complete all as specified and as directed.
S&F Gun matel gate valve with iron wheel head screwed both ends for iron pipe for 15 mm bore, complete all as specified and as directed.
Construction of brick masonary valve pit in repair of size 600x600x600 cm (Internal dimension) with one brick thick wall in CM (1:4) on 100 mm thick PCC (1:4:8) type D2 (using 40 mm graded stone aggregate) as in foundation lean concrete PCC (1:3:6) type C1 (using 20 mm graded stone aggs) as in bedding and coping and 10 mm thick cement plaster in CM (1:4) internally and externally up to 15 cm below ground level providing valve pit cover made of 3 mm thick MS sheet welded with 40 x 40 x 6 mm angle iron frame all round the top fixed by means of 4 Nos hold fast 150 mm long made out of flat iron 40 x 60 mm embeded in PCC block (1:2:4) type B1 (20 mm graded crushed stone aggs)of size 230 x 200 x 100 mm including provision of hinges, welded with angle iron frame and MS cover, MS handle of suitable length, and size welded with MS cover and suitable locking arrangement with applying two coat of synthetic enamel paint over one coat of red oxide, zinc crome primer and necessary excavation and earth work in soft/ loose soil, complete all as specified and as directed.
M/S. JAGDISH PRASAD AGARWALA
BINOD TRADING CO.
M/S MOHAN KUMAR BANSAL
L. B. SHARMA
samrat saw mill and joinery workshop
ANUP ENGINEERING WORKS
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .