Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹1.4 CrAccepted-AOC AT BRAHMANABASTA KAKHADI CUTTACK 75437 | 75437 | ₹1.4 Cr | 1 | Accepted-AOC L1 |
| 2 | 2₹2.0 Cr+₹60.8 L (45.0%)Rejected-Finance | ₹2.0 Cr+₹60.8 L (45.0%) | 2 | Rejected-Finance NOT BEING L1 |
| Sl No | Description | Qty | Unit | SOUMIT PANDA L1 | SJ ENVIRONMENTAL SOLUTIONS L2 |
|---|---|---|---|---|---|
| 1.00Guali Mines in Keonjhar District (30 KLD STP) | |||||
| 1.01 | Site Survey, design & drawing of STP with allied infrastructure such as Connecting existing line/ Septic tank to STP as per schematic drawing attached for acceptance of OMC. | 1 | Sets | 7,00,000 ₹7,00,000 | 4,95,000 ₹4,95,000 Lowest |
| 1.02 | Construction of 30 KLD STP ( Civil portion) as per the drawing attached and as directed by Engineer-in-Charge. | 1 | Each | 16,00,000 ₹16,00,000 | 1,71,000 ₹1,71,000 Lowest |
| 1.03 | Supply of electro-mechanical equipment for 30 KLD STP as designd and as directed by Engineer-in-Charge. | 1 | Set | 13,00,000 ₹13,00,000 Lowest | 32,50,000 ₹32,50,000 |
| 1.04 | Installation of all electro-mechanical equipment along with its fittings and fixtures all complete as per the design drawing/ as directed by engineer in carge. | 1 | Set | 2,00,000 ₹2,00,000 Lowest | 3,25,000 ₹3,25,000 |
| 1.05 | Supply, installation, completion of sewer pipeline ,Laying ( to level or slopes) conforming to IS 783-1959 and jointing with Cement Mortar (1:2) of Concrete pipes Class NP-2 , reinforced light duty non-pressure pipes conforming to IS:458-2003 with collars & butt ends prepared for Collar joints of the following internal diameter. Excavation in all kind of soil including hard rock & cutting the CC/BT road and excavation using machine and mending to its original state as required at site.
A. 150 mm dia NP 2 Hume pipe. or B. 150 mm dia PVC SWR pipe IS-13592 class -B of 6 kg /cm2 pressure rating with C.C (1:1.5:3) all round encasing as detailed on BID doc and as directed by EIC. | 180 | Mtr | 1,000 ₹1,80,000 Lowest | 2,515 ₹4,52,700 |
| 1.06 | Supply, installation, laying & completion of sewer pipeline HDPE tubes of 10Kg/sqcm confirming to I.S No. 4984/1995 the following outer diameter & tube fittings including testing as per specification complete excluding earth work, excavation in all kind of soil including hard rock & cutting the CC/BT road and excavation using machine and mending to its original state as required at site.as per design drawing approx. (meter of size) as below:
A. 75 mm dia HDPE pipe (Grade-PE-63) and as directed by EIC. | 200 | Mtr | 600 ₹1,20,000 Lowest | 865 ₹1,73,000 |
| 1.07 | Dismantling, reconstruction and reconnection of old infra to new infra with all required accessories for smooth operation of STP along with New Manhole as per the NIT for pumping as may be required at site with PVC SWR pipe IS-13592 class -B of 6 kg /cm2 pressure rating. | 1 | Set | 1,50,000 ₹1,50,000 Lowest | 4,20,000 ₹4,20,000 |
| 1.08 | Initial 72 hrs Hydro test for all constructed civil structures and trial commissioning of STP. | 1 | Set | 80,000 ₹80,000 Lowest | 1,70,000 ₹1,70,000 |
| 1.09 | Commission and trial run for 3 months with respective test reports fortnightly for outlet quality and monthly for inlet quality of raw sewage as below parameters:
A. pH
B.TSS
C. TDS
D.BOD
E.COD
F.Oil & Grease
G.Ammonia | 1 | Set | 1,00,000 ₹1,00,000 Lowest | 3,02,500 ₹3,02,500 |
Tender Value
Refer Docs
EMD Value
₹60,000
Closing Date
22 Mar 2022, 5:00 pmClosed
CGM(C), OMC Ltd., Bhubaneswar
Office of the CGM(C), OMC Ltd., Bhubaneswar
Installation, testing and commissioning of 30 KLD STP at Guali Mines and 30 KLD STP at Khandabandh Mines in the dist of Keonjhar along with 03 years operation and maintenance contract.
2022_OMC_76219_3
NIT No. 8/OMC/CIVIL/2022
Open Tender
Civil Works - Others
Item Rate
180 days
GUALI AND KHANDABANDH
Registered Firm, Company or Contractor, EPF Regd., GSTN, PAN, Affidavits, experience, etc. as per DTCN.
2 documents required · 2 mandatory
₹11,800
₹60,000
Yes
3 Sept 2025
8 Mar 2022
23 Mar 2022
8 Mar 2022
22 Mar 2022
8 Mar 2022
Amount
Guali Mines in Keonjhar District (30 KLD STP)
Site Survey, design & drawing of STP with allied infrastructure such as Connecting existing line/ Septic tank to STP as per schematic drawing attached for acceptance of OMC.
Construction of 30 KLD STP ( Civil portion) as per the drawing attached and as directed by Engineer-in-Charge.
Supply of electro-mechanical equipment for 30 KLD STP as designd and as directed by Engineer-in-Charge.
Installation of all electro-mechanical equipment along with its fittings and fixtures all complete as per the design drawing/ as directed by engineer in carge.
Supply, installation, completion of sewer pipeline ,Laying ( to level or slopes) conforming to IS 783-1959 and jointing with Cement Mortar (1:2) of Concrete pipes Class NP-2 , reinforced light duty non-pressure pipes conforming to IS:458-2003 with collars & butt ends prepared for Collar joints of the following internal diameter. Excavation in all kind of soil including hard rock & cutting the CC/BT road and excavation using machine and mending to its original state as required at site. A. 150 mm dia NP 2 Hume pipe. or B. 150 mm dia PVC SWR pipe IS-13592 class -B of 6 kg /cm2 pressure rating with C.C (1:1.5:3) all round encasing as detailed on BID doc and as directed by EIC.
Supply, installation, laying & completion of sewer pipeline HDPE tubes of 10Kg/sqcm confirming to I.S No. 4984/1995 the following outer diameter & tube fittings including testing as per specification complete excluding earth work, excavation in all kind of soil including hard rock & cutting the CC/BT road and excavation using machine and mending to its original state as required at site.as per design drawing approx. (meter of size) as below: A. 75 mm dia HDPE pipe (Grade-PE-63) and as directed by EIC.
Dismantling, reconstruction and reconnection of old infra to new infra with all required accessories for smooth operation of STP along with New Manhole as per the NIT for pumping as may be required at site with PVC SWR pipe IS-13592 class -B of 6 kg /cm2 pressure rating.
Initial 72 hrs Hydro test for all constructed civil structures and trial commissioning of STP.
Commission and trial run for 3 months with respective test reports fortnightly for outlet quality and monthly for inlet quality of raw sewage as below parameters: A. pH B.TSS C. TDS D.BOD E.COD F.Oil & Grease G.Ammonia
OMC for 3 years Annual Operation & Maintenance of STP (Sewarage Treatment Plant) including repairs and replacements & periodical preventive maintenance of all pumps, equipments, acessories and other electro-mechanical units with supply of necessary manpower including supervisory staff and deployment of technical experts / skilled technicians as may be required for effective operation of the STP and with supply of neccesary chemicals, lubricants, consumables / biomass culture etc. all cpmplete for successful operation of the STP ( Excluding cost of power supply)
1st year
2nd year
3rd year
Khandabandh Mines in Keonjhar District (30 KLD STP)
Site Survey, design & drawing of STP with allied infrastructure such as Connecting existing line/ Septic tank to STP as per schematic drawing attached for acceptance of OMC.
Construction of 30 KLD STP ( Civil portion) as per the drawing attached and as directed by Engineer-in-Charge.
Supply of electro-mechanical equipment for 30 KLD STP as designd and as directed by Engineer-in-Charge.
Installation of all electro-mechanical equipment along with its fittings and fixtures all complete as per the design drawing/ as directed by engineer in carge.
Supply, installation, completion of sewer pipeline ,Laying ( to level or slopes) conforming to IS 783-1959 and jointing with Cement Mortar (1:2) of Concrete pipes Class NP-2 , reinforced light duty non-pressure pipes conforming to IS:458-2003 with collars & butt ends prepared for Collar joints of the following internal diameter. Excavation in all kind of soil including hard rock & cutting the CC/BT road and excavation using machine and mending to its original state as required at site. A. 150 mm dia NP 2 Hume pipe. or B. 150 mm dia PVC SWR pipe IS-13592 class -B of 6 kg /cm2 pressure rating with C.C (1:1.5:3) all round encasing as detailed on BID doc and as directed by EIC.
Supply, installation, laying & completion of sewer pipeline HDPE tubes of 10Kg/sqcm confirming to I.S No. 4984/1995 the following outer diameter & tube fittings including testing as per specification complete excluding earth work, excavation in all kind of soil including hard rock & cutting the CC/BT road and excavation using machine and mending to its original state as required at site.as per design drawing approx. (meter of size) as below: A. 75 mm dia HDPE pipe (Grade-PE-63) and as directed by EIC.
Dismantling, reconstruction and reconnection of old infra to new infra with all required accessories for smooth operation of STP along with New Manhole as per the NIT for pumping as may be required at site with PVC SWR pipe IS-13592 class -B of 6 kg /cm2 pressure rating.
Initial 72 hrs Hydro test for all constructed civil structures and trial commissioning of STP.
Commission and trial run for 3 months with respective test reports fortnightly for outlet quality and monthly for inlet quality of raw sewage as below parameters: A. pH B.TSS C. TDS D.BOD E.COD F.Oil & Grease G.Ammonia
OMC for 3 years Annual Operation & Maintenance of STP (Sewarage Treatment Plant) including repairs and replacements & periodical preventive maintenance of all pumps, equipments, acessories and other electro-mechanical units with supply of necessary manpower including supervisory staff and deployment of technical experts / skilled technicians as may be required for effective operation of the STP and with supply of neccesary chemicals, lubricants, consumables / biomass culture etc. all cpmplete for successful operation of the STP ( Excluding cost of power supply)
1st year
2nd year
3rd year
SJ ENVIRONMENTAL SOLUTIONS
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .