| 3 | L3₹43.5 L+₹5.6 L (14.7%)Rejected-Finance 3 SHITALNATH FLATE 1 NR KHANPUR JAIN TEMPLE OPP BANK OF INDIA SHAHPUR AHMEDABAD GUJARAT 380001 | AHMADABAD | GUJARAT | 380001 | L3 | Rejected-Finance Other than lowest | |
| 4 | Rejected-Technical PLOT NO 626 627 GIDC BEHIND GANGOTRI DIARY PORBANDAR 360 577 | PORBANDAR | GUJARAT | 360577 | - | Rejected-Technical Adverse Remarks in WLR of ADG (P) Chennai QE Mar 2025. |
Tender Value
Refer Docs
EMD Value
₹77,000
Closing Date
18 Jun 2025, 6:00 pmClosed
GE Navy Porbandar
GE Navy Porbandar Tija Mile Porbandar
MAINTENANCE / REPAIR / REPLACEMENT OF STREET AND SOLAR LIGHTS, LIGHT POLES, UG CABLE LINKS, FEEDER PILLAR BOXES, APFC PANELS, INCLUDING PREVENTIVE MAINTENANCE AND EXTERNAL WATER SUPPLY INSTALLATIONS GI/CI/DI PIPE LINES PUMP ELECTRIC MOTORS VALVES
2025_MES_709430_1
8884/Okha/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
GE Navy Porbandar
Please refer Tender Documents
7 documents required · 7 mandatory
₹500
Garrison Engineer Navy
₹77,000
Yes
22 Jul 2025
21 May 2025
20 Jun 2025
21 May 2025
18 Jun 2025
4 Jun 2025
21 May 2025 - 3 Jun 2025
Amount
Earth work in excavation by mechanical means (Hydraulic excavator) / in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50m as directed by Engineer-in-charge
Excavation in trenches for soft/disintegrated rock n.exc 1.5 m wide and n.exc 1.5 m deep and getting out for taking out/laying of UG cable LT of any size complete all as specified and directed
Excavation in trenches in Hard/ dense soil n exc 1.5 m wide and n exc 1.5 m deep and getting out, required to repair the leakage of CI pipes & fittings,including demolition of PCC/road cutting and making good to match the existing surface after repair works complete all as specified and directed
Returning and filling in trenches incl spreading, levelling watering and raming in layer n.exc 25 cm in soft/disintegrated rock complete all as specified and directed.
Returning and filling in trenches incl spreading, levelling watering and raming in layer n.exc 25 cm in any type of soil complete all as specified and directed.
Removing of excavated mtrls n.exc 50 m and depositing where directed at a level n.exc 1.5 m above the starting point in any type of soil.
Supply and fix in Repair/Replacement for laying/jointing GI Pipe light grade 50mm dia with all fittings laid/fixed on wall/pole or under road/PCC crossing and all as specified and directed.
Supply and fix in Repair/Replacement for laying/jointing GI Pipe light grade 80mm dia with all fittings laid/fixed on wall/pole or under road/PCC crossing and all as specified and directed.
Supply and fix in Repair/Replacement for laying/jointing GI Pipe light grade 40mm dia with all fittings laid/fixed on wall/pole or under road/PCC crossing and all as specified and directed.
Supply and fix in Repair/Replacement for Laying in trenches or passing through pipe,10 Sqmm 4 core LT XLPE cable with stranded aluminium conductor heavy duth for 1100 volts grade cross sectional area complete all as specified and as directed.
Supply and fix in Repair/Replacement for Laying in trenches or passing through pipe,16 Sqmm 4 core LT XLPE cable with stranded aluminium conductor heavy duth for 1100 volts grade cross sectional area complete all as specified and as directed.
Supply and fix in Repair/Replacement for Laying in trenches or passing through pipe,25 Sqmm 4 core LT XLPE cable with stranded aluminium conductor heavy duth for 1100 volts grade cross sectional area complete all as specified and as directed.
Supply and fix in Repair/Replacement for Laying in trenches or passing through pipe,50 Sqmm 3.5 core LT XLPE cable with stranded aluminium conductor heavy duth for 1100 volts grade cross sectional area complete all as specified and as directed.
Supply and fix in Repair/Replacement for Laying in trenches or passing through pipe,95 Sqmm 3.5 core LT XLPE cable with stranded aluminium conductor heavy duth for 1100 volts grade cross sectional area complete all as specified and as directed.
Supply and fix in Repair/Replacement for 400 AMP MCCB, 4 pole 415 volt, AC 50 Hz, 4 pole, 36 KA with adjustable type against over load and short circuit conditions incl neutral adjustment of capacity suitable of Existing panel board for replace of unserviseble MCCB complete all as specified and directed. Make:- Havells/ Legrand/L&T/C&S
Supply and fix in Repair/Replacement for 250 AMP MCCB, 4 pole 415 volt, AC 50 Hz, 4 pole, 25 KA with adjustable type against over load and short circuit conditions incl neutral adjustment of capacity suitable of Existing panel board for replace of unserviseble MCCB complete all as specified and directed. Make:- Havells/ Legrand/L&T/C&S
Supply and fix in Repair/Replacement for 200 AMP MCCB, 4 pole 415 volt, AC 50 Hz, 4 pole, 25 KA with adjustable type against over load and short circuit conditions incl neutral adjustment of capacity suitable of Existing panel board for replace of unserviseble MCCB complete all as specified and directed. Make:- Havells/ Legrand/L&T/C&S
Supply and fix in Repair/Replacement for 160 AMP MCCB, 4 pole 415 volt, AC 50 Hz, 4 pole, 36 KA with adjustabletype against over load and short circuit conditions incl neutral adjustment of capacity suitable of Existing panel board for replace of unserviseble MCCB complete all as specified and directed. Make:- Havells/ Legrand/L&T/C&S
Supply and Repair/Replacement for 100 AMP MCCB, 4 pole 415 volt, AC 50 Hz, 4 pole, 25 KA with adjustabletypeagainst over load and short circuit conditions incl neutral adjustment of capacity suitable of Existing panel board for replace of unserviseble MCCB complete all as specified and directed. Make : Havells/ Legrand/L&T/C&S
Supply and Repair/Replacement for 63 AMP MCCB, 4 pole 415 volt, AC 50 Hz, 4 pole, 25 KA with adjustabletypeagainst over load and short circuit conditions incl neutral adjustment of capacity suitable of Existing panel board for replace of unserviseble MCCB complete all as specified and directed. Make : Havells/ Legrand/L&T/C&S
M&L for earthing complete with galvanized steel earth plate electrode of size 600 x 600 x 6 mm thick buried directly in ground to a depth not less than 2.25 mtr below the normal ground level with top edge of earth plate not less than 1.50 mtr below the normal ground level and connected to GI strips 25 x 4 mm by means of nut, bolt & washer and protected by 40mm dia GI pipe light grade and watering pipe of 20mm dia GI pipes light grade and connected to earth test point including necessary excavation, earth work, PCC chamber (1:3:6) type C-1 and 40 mm thick RCC pit cover in RCC (1:2:4) type B-1 using 6 mm dia MS round bars @ 150 mm C/C both ways all as shown in electrical plate No. 3 of SSR Part-I all as specified and directed.
M&L for earthing complete with galvanized steel earth plate electrode of size 600 x 600 x 6 mm thick buried directly in ground to a depth not less than 2.25 mtr below the normal ground level with top edge of earth plate not less than 1.50 mtr below the normal ground level and connected to GI wire 4.0mm dia by means of nut, bolt & washer and protected by 40mm dia GI pipe light grade and watering pipe of 20mm dia GI pipes light grade and connected to earth test point including necessary excavation, earth work, PCC chamber (1:3:6) type C-1 and 40 mm thick RCC pit cover in RCC (1:2:4) type B-1 using 6 mm dia MS round bars @ 150 mm C/C both ways all as shown in electrical plate No. 3 of SSR Part-I all as specified and directed.
Supply ony Lug aluminium suitable cable size of 50 to 150 sqmm complete all as specified and directed Engineer-in-Charge.
Supply ony Lug aluminium suitable cable size of 16 to 50 sqmm complete all as specified and directed Engineer-in-Charge.
Supply and Repair/Replacement of Onload change over switch 400 Amp four pole changeover, 415 Vac, 50 Hz by connecting the electrical connection and fixing on panal with nut, bolt,clamps complete all as specified and as directed by Engr-in-Charge. Make Havells/ABB/L&T/C&S
Taking out panel door with old broken hinges and supply and fix with new MS hinges medium weight of 75mm long fix to panel & panel door with suitable nut & bolt /welding and Painting of LT panel with two coats of synthetic enamel paint of existing colour complete exc 5 sqm n exec 10 sqm complete all as specified and directed.
Supply and Fixing of Cable jointing kit for 1100 V (Earthed) grade cable for Straigt through joint heat shrink type joint complete with jointing material and accessories suitable for 3.5/4 core XLPE armoured aluminium conductor cable of size150 sqmm to 240 sqmm complete all as specified and directed Engr-in-Charge.Make :- 3M/Raychem and equivalent
Supply and Fixing of Cable jointing kit for 1100 V (Earthed) grade cable for Straigt through joint heat shrink type joint complete with jointing material and accessories suitable for 3.5/4 core XLPE armoured aluminium conductor cable of size 70sqmm to 120 sqmm complete all as specified and directed Engr-in-Charge.Make :- 3M/Raychem and equivalent
Supply and Fixing of Cable jointing kit for 1100 V (Earthed) grade cable for Straigt through joint heat shrink type joint complete with jointing material and accessories suitable for 3.5/4 core XLPE armoured aluminium conductor cable of size 25 sqmm to 70 sqmm complete all as specified and directed Engr-in-Charge.Make :- 3M/Raychem and equivalent
S&F in Repeir/Replacement of panel mounted volt meter digital type 3 phase 0-500V as per existing complete all as specified and directed
S&F in Repeir/Replacement of panel mounted Ammeter digital type 3 phase 0-500V as per existing complete all as specified and directed
M&L for Cement Concrete 1:4:8 (40mm Graded Stone Aggregate) as in Foundation of Poles, Stays, etc. including Formwork (as/if required), complete all as specified and as directed.
M&L for Cement Concrete 1:2:4 (20mm Graded Stone Aggregate) as in Coping of Poles, etc. including Formwork (as/if required), complete all as specified and as directed.
M&L for Cement Concrete 1:3:6 (40mm Graded Stone Aggregate) as in Foundation of Poles, Stays, etc. including Formwork (as/if required), complete all as specified and as directed.
S&F in Repair/Replacement for erecting of steel tubular swaged poles swan neck type complete with cast iron base plate, finial taper plug, Cap, mild steel bolts, nuts,screw, etc. type 410 SP-31(9.0 meters long) complete all as specified and directed.
S&F in Repair/Replacement for erecting of Prestressed concrege pole 9.0 metres long, 102x152mm at top and 102x289mm at bottom, class 10
Material and labour for painting to Prestressed concrete pole 9.00 metre long two coats of synthetic enamel paint complete all as specified and directed by Engineer-in-Charge
Material and labour for painting to steel tubular pole 9.00 metre long with one coat of red oxide on pole and two coats of synthetic enamel aluminium paint complete all as specified and directed by Engineer-in-Charge
Material and labour for numbering of pole No. Using radium sticker of superier quality with back of Black round and fonts with white in colour complete all as specified and directed by Engineer-in-Charge.
S&F in replacement on pole street light bracket fabricated out of GI Tubing light grade 40 mm bore Bend to the shape as directed and of length 1.5 mtr complete with mounting MS clamp of flat iron of suitable size 02 Nos incl nut bolts Etc of suitable size all as specified and directed by Engr In charge
Supply and fix in Repair/Replacement of hot press moulded SMC junction box door fixed with left side hinged inside dimension of 240x130x95 mm Fixed with cable terminals with one number of 16 Amp SP MCB incl fixed on pole with clamp nuts,bolts etc complete all as specified and directed by Engineer-in-charge.Make-Sintex/Hensal
Supply and fix in Repair/Replacement for Timer switches Digital type programmable for street light connected to contactor complete all as specified and directed.
Supply and fix in Repair/Replacement of power contactor 3 pole MCX-04 suitable for street light connected to timer complete all as specified and as directed.Make - L&T/C&S/Havells
Supply and fix in Repair/Replacement of MCB SPN 6-32Amps,10 KA breaking capacity 230 V,50 Hz for lighting and other domestic load complete all as specified and directed by Engineer - in - Charge.
Supply and fix in Repair/Replacement of MCB TP 63 Amps, 10 KA breaking capacity 230 V, 50 Hz AC Supply complete all as specified and directed by Engineer - in - Charge.Make:- Anchor/C&S/L&T
Supply and fix in Repair/Replacement of MCB TPN 63 Amps, 10 KA breaking capacity 230 V, 50 Hz AC Supply complete all as specified and directed by Engineer - in - Charge.Make:- Anchor/C&S/L&T
Supply and fix in Repair/Replacement of Building LED street light fitting 35 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete including taking down the u/s street light fittings complete all as specified and as directed.
M&L For repair and maintanance to solar street lights including cleaning of solar panel, filling of distilled water for battery,charging battary and making servicable complete all as specified and directed by Engineer - in - Charge.
Supply and fix in Repair/Replacement of battery 12 volts 80 AH capacity suitable of solar light complete all as specified and directed by Engineer - in - Charge. Make: Exide/Luminious
Supply and fix in Repair/Replacement of LED Solar street light fitting 15 Watt including in built, lithium ion battery, solar panel, charge controller with dusk down sensor complete Make-Havells/Surya/Bajaj
Supply and Repair/Replacement of LED street light fitting 70 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp IP 65/66 protection complete in pole/post/wall position by connecting the electrical connection and tightening the nut,bolts and clamps and all as specified and directed including taking down the u/s street light fittings.
Supply and Repair/Replacement ofLED street light fitting 90 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp IP 65/66 protection complete in pole/post/wall position by connecting the electrical connection and tightening the nut,bolts and clamps and all as specified and directed including taking down the u/s street light fittings.
Supply and Repair/Replacement of flood light LED luminaire white150 watt IP -65 flood light with highlighting architecturel facade highmast/basket ball court/ squach court/batmittan court light complete all as specified and directed including taking down the u/s flood light fittings. Make:- Havells/C&S/CG
Supply and fix of Integral LED aviation luminare light comprising of aluminium housing with polycarbonate enclosure complete in highmast light in position by connecting the electrical connection and tightening the nut,bolts and clamps and all as specified and directed including taking down the u/s aviation light fittings.
Supply and Repair/Replacement of decorative gate light moon (opal) type made up of high grade unbreakeble polycarbonate material suitable for retrofit B22 base and 60 mm pole dia with 7/9 watt LED lamp complete all as specified and direcred by Engineer-in-Charge
Supply and Repair/Replacement of new generation post top energy saving environmental friendly,long life aesthetically designed with symmetrical light distribution,spun aluminium landscape luminaire with high power LED as light sourse Coral (opal) - IP65 suitable for pole dia 76 mm with 25 watt LED lamp complete all as specified and directed by Engineer - in - Charge. Make :- Havells Cat No:-CORALPT25WLED757PSYMTOPC or its equivalent in Bajaj/C&S
Supply and Repair/Replacement of Garden Bollard light BGBOM 650 9W LED Bollards lightDie cast aluminium graphite grey powder coated GI Pipe Housing ,Mushroom shape opal acrylic diffuser if fixed in die-cast aluminium base for pleasant light output,LED mounted on die-cast aluminium base,IP-65, 240 Volt,Luminaire is provided with base plate and fixing holes for directely mounting on the concrete pedestal including including taking down the u/s street light fittings complete all as specified and as directed. Make:- Cat part No. BAMBOOBL8WLED857PSYMTOPCM of Havells Make or its equivalent in Bajaj/C&S/Wipro.
Supply and lay Double Walled Corrugated (DWC) Pipes of dia 50mm having corrugation on the outer wall and plain surface on the inner wall confirming to IS14930 (Part-II) for protection of UG cables size 50 mm outer dia laid in trenches/ road/ drain or fixed along wall, poles or laid under floor all as spd and as directed by Engr-In-Charge.
Supply and lay Double Walled Corrugated (DWC) Pipes of dia 63mm having corrugation on the outer wall and plain surface on the inner wall confirming to IS14930 (Part-II) for protection of UG cables size 63 mm outer dia laid in trenches/ road/ drain or fixed along wall, poles or laid under floor all as spd and as directed by Engr-In-Charge.
Supply and fix in Repair/Replcement for weather proof flat twin core 6 sqmm multistrand Aluminium conductor cable with PVC conduit of dia 25mm with accessories complete all as specified and directed by Engineer-in-Charge.
Supply and fix in Repair/Replacement for Cable with copper conductor PVC round sheathed (flexible) 3 core 2.5 sqmm industrial cable complete all as specified and directed by Engineer-in-Charge.
Supply and Repair/Replacement for Cable with copper conductor PVC round sheathed (flexible) 3 core 4 sqmm industrial cable complete all as specified and directed by Engineer-in-Charge.
Supply and Repair/Replacement of LED Solar street light fitting 15 Watt with inbuilt solar charge controller with street light bracket suitable size including taking down the u/s solar light fittings compleate all as specified and as directed. sensor complete
Taking down Old unserviceable GI/CI pipe at in any position for repairs and taking credit all as directed for 25 mm bore size pipes/fitings complete all as specified and directed.
All as per item No 66.00 above but 32mm bore
All as per item No 66.00 above but 40 mm bore
All as per item No 66.00 above but 50 mm bore
All as per item No 66.00 above but 80 mm bore
Supplying and laying of CPVC pipe SDR 11 & Plain CPVC SDR 11 of 25mm outer dia of of pipe including fittings such as bends, tees, elbows, short pieces, connectors, back nuts and connections fixed in new or old position in trenches, walls, floors etc complete all as specified and directed.
All as per item No 71.00 above but 32 mm bore
All as per item No 71.00 above but 40 mm bore
All as per item No 71.00 above but 50 mm bore
Supplying and laying of CPVC pipe Schedule 80 pipes & plain CPVC Schedule 80 fittings of 75mm inner dia (80m outer dia) of of pipe including fittings such as bends, tees, elbows, short pieces, connectors, back nuts and connections fixed in new or old position in trenches, walls, floors etc complete all as specified and directed.
Supply and fix in Repair/Replacement of CPVC ball valve 25 mm bore fixed all as specified and directed.
All as per item No 76.00 above but 32mm bore complete all as specified and directed.
All as per item No 76.00 above but 40 mm bore complete all as specified and directed.
Taking down u/s 3 layer PP-R pipes SDR 7.4 & SDR 11 UV stabilised and antimicrobial fusion welded having thermal stability for Hot & Cold water supply all PP-R plain and brass threded polypropylene random fittings concealed/ laid to walls, ceiling or in floor etc for 32 mm Outer Dia complete all as specified and directed.
All as per above item No 79.00 but for 25 mm Outer Dia
Sypply and Repair/Replacement of 3 layer PP-R pipes SDR 7.4 & SDR 11 UV stabilised and antimicrobial fusion welded having thermal stability for Hot & Cold water supply all PP-R plain and brass threded polypropylene random fittings concealed/ laid to walls, ceiling or in floor etc for 32 mm Outer Dia complete all as specified and directed.
All as per above item No 81.00 but 25 mm Outer Dia
S & F in replacement of PPR Gate valve (brass insert) for PP-R pipe 32 mm Outer Dia complete all as specified and directed.
All as per above item No 83.00 but 25 mm Outer Dia
Removing surplus hard dense soil obtained from excavation/ demolition exc 250m but not n exc 500m and depositing at places allowed by BMC all as specified and directed.
Cutting of hard standing/ Road for laying of pipe line and making good surfaces by using PCC 1:2:4 type B-2 after laying of pipe line/ cable up to 30cm in depth and width not exceeding 45cms and removing rubbish outside MD land complete all as specified and as directed.
Disconnecting the electric connection of Centrifugal pump set of capacity upto 3-5 HP(any make) from motor terminal box including insulating the ends of the cable, taking out the pump set from base after opening nuts/bolts, transporting from site to workshop, dismantling pump, removing worn out impeller, ball bearing, gaskets, assembling the pump with replacement of pulley key, gland packing rope, greasing, transporting back to site and fixing on the existing foundation, connecting the electric connection of motor and testing complete to entire satisfaction of Engr-in-charge for the following capacity. (Note :- Major spare parts shall be measured and paid separately, minor spares deemed to in rate quoted, spares like pump shaft, impeller and bearing only will be measured and paid separately under relevant items.
Supply only Stainless pump shaft suitable for 5 HP (Make : Match as per existing)
Supply only Cast iron impeller enclosed sitable for 5 HP (Make : Match as per existing)
Note: - Labour charges for fixing of item No. 88.00 & 89.00 are included in item No. 87 above.
Material and labour for rewinding the electric motor of capacity 3-5 HP HP capacity, disconnecting the electric connection of motors, earth connections, decoupling motor and pump, removing foundation nuts/bolts and removing the motors from its existing position to workshop (Note : following work are to be deemed in rate quoted).
Removing the split case/body cover of motor, separate stator/rotor and cutting the complete burnt/defective copper winding.
Cleaning the stator body complete by rubbing sand paper remove all carbons.
Insert insulating materials such as insulating paper sleeves.
Rewinding the stator with existing size of super enameled copper winding, varnishing and heating up at desired temp. For achieve the particular Ohm resistance.
Clean the rotor and assembling in motor.
Connection/coupling the motor with pump, connect all electric/earth connection foundation nuts/bolts at its original position and testing on load complete all as specified and directed.
Dismantling and taking down old u/s starter of any make and Supply and fix starter suitable for upto 5 hp motor type MK-1 complete with sheet-steel enclosure complete all as specified and directed.
Fabricate, supply & fix in replacement MS sheet plain 4 mm thick of required size & shape including necessary fabrication as required & ordered for valve chamber cover/covers in sump opening including fixing with frames by means of hinges & painting with two coats of synthetic enamel paint over primer of red oxide complete.
M&L in replacement GI tubing medium grade galvanised with all fittings, Bends etc fix to wall and ceiling/lead on floor of UG sump, complete incl dismantling old pipes of any length for 50 mm dia bore sizes
M&L in replacement GI tubing medium grade galvanised with all fittings, Bends etc fix to wall and ceiling/lead on floor of UG sump, complete incl dismantling old pipes of any length for 40 mm dia bore sizes
JAY BHARAT METAL SUPPLIERS (BID ID -3322577)
shree chamunda enterprise (BID ID -3322853)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .