Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance VP 10 323 CHITHRALAYAM NALANKALLU VILAVOORKAL MALAYINKEEZHU THIRUVANANTHAPURAM 695571 | THIRUVANANTHAPURAM | KERALA | 695571 | Admitted-Finance |
| 2 | Admitted-Finance | Admitted-Finance |
Tender Value
₹21.6 L
EMD Value
₹32,392
Closing Date
17 Jan 2022, 3:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Deputy Vice President (HCD)
HLL Lifecare Limited, HLL Bhavan, No26/4, Tambaram-Velachery Main Road, Pallikaranai, Chennai 600 100, Tamilnadu, India Ph 044 -2981 3732/34
Setting Up of 5 Bedded Pediatric ICU in THQH Alathur, Palakkad Palakkad District under ECRP II
2021_HLL_459984_2
HLL/CHO/HCD/PS/ECRPII/ALTRPKD
Open Tender
Civil Works - Buildings
Item Rate
45 days
THQH Alathur, Palakkad
Please refer Tender documents.
10 documents required · 10 mandatory
₹2,800
₹32,392
Yes
20 Jan 2022
10 Jan 2022
18 Jan 2022
10 Jan 2022
17 Jan 2022
10 Jan 2022
180 days
Amount
ECRP Projects
Civil Work
Wall painting with acrylic emulsion paint of approved brand and manufacture to give an even shade:Two or more coats on new work
Aluminium works
For shutters of doors, windows & ventilators including providing and fixing hinges / pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber/ neoprene gasket required (Fittings shall be paid for separately)Powder coated aluminium (minimum thickness of powder coating 50 micron)
Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of Engineer - in -Charge. ( Cost of aluminium snap beading shall be paid in basic item):With float glass panes of 5.50 mm thickness
Providing and fixing aluminium round shape handle of outer dia 100 mm with SS screws etc. complete as per direction of Engineer-in-Charge.Powder coated minimum thickness 50 micron aluminium
Providing and fixing aluminium hanging floor door stopper, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS: 1868) transparent or dyed to required colour and shade, with necessary screws etc. complete.Single rubber stopper
Providing and fixing aluminium extruded section body tubular type universal hydraulic door closer (having brand logo with ISI, IS : 3564, embossed on the body, door weight upto 36 kg to 80 kg and door width form 701 mm to 1000 mm), with double speed adjustment with necessary accessories and screws etc. complete.
Providing and fixing aluminium tower bolts, ISI marked, anodised(anodic coating not less than grade AC 10 as per : 1868), transparent or dyed to required colour or shade, with necessary screws complete:100x10 mm
Providing and fixing aluminium hanging floor door stopper, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS: 1868) transparent or dyed to required colour and shade, with necessary screws etc. complete.Single rubber stopper
Providing and fixing 9 mm thick prelaminated particle board flat pressed three layer or graded wood particle board conforming to IS : 12823 Grade I Type II, in panelling fixed in aluminum doors, windows shutters and partition frames with C.P. brass / stainless steel screws etc. complete as per architectural drawings and directions of Engineer - in- Charge.<br>Pre- laminated particle board with decorative lamination on both sides
Electrical Work
NEGATIVE PRESSURE WORKS
Supply ,Installation of Thermal Insulation of ducting using Closed Cell Elastomeric nitrile rubber having a density of 40-60 Kg/m3 and with Microban Certified anti-microbial protection etc. complete as required - 9mm
SFTC - Supply Air Grilles W/O damper<br>Supplying, fixing, testing & commissioning of powder coated extruded aluminum supply air grills without collar dampers as per specifications. etc. complete as required
HEPA FILTER - NEGATIVE PRESSURE<br>Supply and installation of 1500CFM Flange type HEPA filters (610X610X300MM) efficiency not less than 99.99% for particles of size down to 0.3 micron at exhaust system terminal collars.
4000 CFM cabinet Type Exhaust Fan with 60mm ESP<br>Supply, installation, testing & commissioning of Double skin construction Suspended type with 25 mm thick Sandwiched PUF insulation .Forward/ Backward curved fan with min 70% Efficiency, centrifugal fan belt drive and vibration isolators Guard for inspection door , Pre filter of 10 micron and squirrel cage induction motor EFF1 Grade. Motor with 3.7KW shall be suitable for 415±10% volts, 50 cycles/second, 3 phase AC supply and also suitable for DOL normal Starter switch
2000CFM cabinet Type Fresh Air Fan with 20mm ESP.<br>Supply, installation, testing & commissioning of Single skin construction Suspended type with min 70% Efficiency, centrifugal forward drive fan and vibration isolators, , Guard for inspection door , Pre filter of 10 micron and squirrel cage induction motor EFF1 Grade. Motor with .55KW shall be suitable for 220±10% volts, 50 cycles/second, 1 phase AC supply, or else any higher or equivalent as approved by Engineer in Charge.
SITC 63A RCCB<br>Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current upto 30 milliamperes in the existing MCB DB complete with connections, testing and commissioning etc. as required.<br>63 amps
CANVAS CONNECTOR FOR AC WORKS<br>SITC of thermal insulated, flexible type canvas connector and ribbed rubber pads as vibration isolator in the existing machine to duct mouth using suitable adhesive compound as per technical specification, neatly bolted and adjusted for vibration free mounting etc as required.
DUCTING .8mm GSS<br>Supply, installation, balancing and commissioning of fabricated at site GSS sheet metal rectangular/round ducting complete with neoprene rubber gaskets, elbows, splitter dampers, vanes, hangers, supports etc. as per approved drawings and specifications of following sheet thickness complete as required.<br>Site fabricated GSS sheet metal rectangular ducting as per IS 655-2006 for 0.8. mm thick
DUCTING .6mm GSS<br>Supply, installation, balancing and commissioning of fabricated at site GSS sheet metal rectangular/round ducting complete with neoprene rubber gaskets, elbows, splitter dampers, vanes, hangers, supports etc. as per approved drawings and specifications of following sheet thickness complete as required.<br>Site fabricated GSS sheet metal rectangular ducting as per IS 655-2006 for 0.63 mm thick
MEDICAL GAS WORKS
OXYGEN MANIFOLD 3X3 WITH High Pressure Tail Pipe and NRV <br>SITC of 3 + 3 /3x 3 Cylinder Oxygen Manifold suitable to withstand a pressure of 140 Kg/Cm2 and above along with high pressure copper annealed tail pipes with end Brass adapter suitable for Oxygen Cylinders and manifold. Top frame comprising of high pressure copper pipes of size 12mm I.D x 1.5mm wall thick, with high pressure brass fittings made of high tensile brass and connections through non-return values; high pressure copper tail pipes, made of high pressure copper pipe of size 7mm I.D x 1.5mm wall thick. The design of middle and bottom frames would be provided to fit both round and flat bottom cylinders safely. The manifold should be tested (hydraulically) at 3500 pig at site /factory without any additional cost or claim by the contractor for certification and installation, all necessary arrangement for testing shall be under the scope of contractor.
15mm OD X .9mm THICK Cu PIPE<br>SITC of copper pipes manufactured from phosphorous deoxidised non-arsenical copper of grade CW024A (Cu-DHP), manufactured EN 13348:2008 to metric outside diameters and having mechanical properties, pipes shall be of R250 (half hard)temper. Pipes shall be degreased suitable for oxygen use and cleanliness is to be maintained by filling each pipe with dry, clean, oil and oxygen free nitrogen, fitting suitable end caps and protectively wrapping. Solid drawn, seamless, deoxidised, non- arsenical, half hard, tempered and degreased copper tubes manufactured to metric outside diameters and should have mechanical properties in accordance with HTM 02-01 and conforming to EN13348:2008.The pipes should also be accompanied with manufacturer’s test certificate for the physical and chemical composition. Copper Fittings should be as per HTM 02-01. All plastic saddles should have brass screws. as per the specifications and requirements, painting of the pipes installed as per color code for medical gas system is also under the scope of contractor<br>20 mm
12mm OD X .7mm THICK Cu PIPE<br>SITC of copper pipes manufactured from phosphorous deoxidised non-arsenical copper of grade CW024A (Cu-DHP), manufactured EN 13348:2008 to metric outside diameters and having mechanical properties, pipes shall be of R250 (half hard)temper. Pipes shall be degreased suitable for oxygen use and cleanliness is to be maintained by filling each pipe with dry, clean, oil and oxygen free nitrogen, fitting suitable end caps and protectively wrapping. Solid drawn, seamless, deoxidised, non- arsenical, half hard, tempered and degreased copper tubes manufactured to metric outside diameters and should have mechanical properties in accordance with HTM 02-01 and conforming to EN13348:2008.The pipes should also be accompanied with manufacturer’s test certificate for the physical and chemical composition. Copper Fittings should be as per HTM 02-01. All plastic saddles should have brass screws. as per the specifications and requirements, painting of the pipes installed as per color code for medical gas system is also under the scope of contractor<br>20 mm
15 mm BALL VALVE (MGPS)<br>SITC of Line Valves for use in plant rooms and to facilitate the isolation of areas or areas where area zone valve are unnecessary. These shall be of the ball valve type and shall be constructed of a nickel plated brass body, PTFE seats and brass chrome plated ball. The valve shall be operated by a manual operating lever by 90º turn. All medical gas line ball valves shall provide a full bore flow and shall be cleaned for oxygen service and fully tested. The valve assembly shall terminate in copper stub pipes to enable brazing directly into the distribution system using the flux less brazing technique. A locking device shall be provided to lock the valve in either the fully open or fully closed position. Line valves shall be located in readily accessible areas of ducts and shafts, however care should to ensure safety to prevent danger from leakage. Line valve installation should be carried out as per HTM 2022/HTM 02-01 standards.
Oxygen Flow meter with Humidifier Bottle<br>SITC of Flow meter Back pressure Compensated. Flow meter would be accurate gas flow measurement and control within a range of 0-15 liters per minute. It would meet strict precision and durability standards. Flow meter body would be made of brass material. Flow tube and shroud components would be made of clear, impact resistant polycarbonate. The humidifier bottle would be unbreakable polycarbonate material and autoclavable at 134 degrees centigrade. The humidifier would have built in safety valve.
Gas / Vacuum Outlets<br>SITC of Gas/Vacuum Outlets with Front loading type terminal outlets designed to dispense medical gases or an inlet for medical vacuum to the secondary equipment flow meters, Surgical Tools, Suction regulators, etc. Terminal unit sealed by O ring. The outlets should Quick Connect Type and gas specificity is accomplished by Diametric indexing / Geometric indexing Should have Push to IN and press-to-OUT mechanism for probes. Allows plugging of probes from front. Parking Type probe / connector Self-sealing valve on disengaging the probe (Quick disconnect) Smooth quite action Non return valve for on line servicing/ repairing , Indexed to eliminate inter-changeability of gas services, Color-coded gas specific front plate Flow rate exceeds the requirements of ISO 9170 – 1. Totally leak proof, safe & easy to operate Configurations possible: surface, flush & Bead-head. The terminal outlets should comply with ISO and NFPA. Body shall be of one piece brass construction.
BHP(1.2Mtr) - Providing and Fixing by necessary means of Installation of 1200mm X 600mm Horizontal BHP having -high strength aluminum section, thickness of aluminum section 3 mm. Aluminum Powder coated with provision for Gas Outlets-3 No's & Electrical 5/6amps - 4 No.s ,15/16 Amps switch sockets. - 4 No.s each 1 No. of LAN Point and Phone point with proper RJ connectors, IV holder, Monitor stand with necessary internal wiring using 4 Sq.mm FRLS Cu wire. all relevant QA/QC certificate shall be submitted prior to HLL Engineer in charge before Installation.
22mm OD X .9mm THIICK Cu PIPE<br>SITC of copper pipes manufactured from phosphorous deoxidised non-arsenical copper of grade CW024A (Cu-DHP), manufactured EN 13348:2008 to metric outside diameters and having mechanical properties, pipes shall be of R250 (half hard)temper. Pipes shall be degreased suitable for oxygen use and cleanliness is to be maintained by filling each pipe with dry, clean, oil and oxygen free nitrogen, fitting suitable end caps and protectively wrapping. Solid drawn, seamless, deoxidised, non- arsenical, half hard, tempered and degreased copper tubes manufactured to metric outside diameters and should have mechanical properties in accordance with HTM 02-01 and conforming to EN13348:2008.The pipes should also be accompanied with manufacturer’s test certificate for the physical and chemical composition. Copper Fittings should be as per HTM 02-01. All plastic saddles should have brass screws. as per the specifications and requirements, painting of the pipes installed as per color code for medical gas system is also under the scope of contractor<br>20 mm
35mm OD X 1.2mm THIICK Cu PIPE<br>SITC of copper pipes manufactured from phosphorous deoxidised non-arsenical copper of grade CW024A (Cu-DHP), manufactured EN 13348:2008 to metric outside diameters and having mechanical properties, pipes shall be of R250 (half hard)temper. Pipes shall be degreased suitable for oxygen use and cleanliness is to be maintained by filling each pipe with dry, clean, oil and oxygen free nitrogen, fitting suitable end caps and protectively wrapping. Solid drawn, seamless, deoxidised, non- arsenical, half hard, tempered and degreased copper tubes manufactured to metric outside diameters and should have mechanical properties in accordance with HTM 02-01 and conforming to EN13348:2008.The pipes should also be accompanied with manufacturer’s test certificate for the physical and chemical composition. Copper Fittings should be as per HTM 02-01. All plastic saddles should have brass screws. as per the specifications and requirements, painting of the pipes installed as per color code for medical gas system is also under the scope of contractor<br>20 mm
35 mm BALL VALVE (MGPS)<br>SITC of Line Valves for use in plant rooms and to facilitate the isolation of areas or areas where area zone valve are unnecessary. These shall be of the ball valve type and shall be constructed of a nickel plated brass body, PTFE seats and brass chrome plated ball. The valve shall be operated by a manual operating lever by 90º turn. All medical gas line ball valves shall provide a full bore flow and shall be cleaned for oxygen service and fully tested. The valve assembly shall terminate in copper stub pipes to enable brazing directly into the distribution system using the flux less brazing technique. A locking device shall be provided to lock the valve in either the fully open or fully closed position. Line valves shall be located in readily accessible areas of ducts and shafts, however care should to ensure safety to prevent danger from leakage. Line valve installation should be carried out as per HTM 2022/HTM 02-01 standards.
22 mm BALL VALVE (MGPS)<br>SITC of Line Valves for use in plant rooms and to facilitate the isolation of areas or areas where area zone valve are unnecessary. These shall be of the ball valve type and shall be constructed of a nickel plated brass body, PTFE seats and brass chrome plated ball. The valve shall be operated by a manual operating lever by 90º turn. All medical gas line ball valves shall provide a full bore flow and shall be cleaned for oxygen service and fully tested. The valve assembly shall terminate in copper stub pipes to enable brazing directly into the distribution system using the flux less brazing technique. A locking device shall be provided to lock the valve in either the fully open or fully closed position. Line valves shall be located in readily accessible areas of ducts and shafts, however care should to ensure safety to prevent danger from leakage. Line valve installation should be carried out as per HTM 2022/HTM 02-01 standards
12 mm BALL VALVE (MGPS)<br>SITC of Line Valves for use in plant rooms and to facilitate the isolation of areas or areas where area zone valve are unnecessary. These shall be of the ball valve type and shall be constructed of a nickel plated brass body, PTFE seats and brass chrome plated ball. The valve shall be operated by a manual operating lever by 90º turn. All medical gas line ball valves shall provide a full bore flow and shall be cleaned for oxygen service and fully tested. The valve assembly shall terminate in copper stub pipes to enable brazing directly into the distribution system using the flux less brazing technique. A locking device shall be provided to lock the valve in either the fully open or fully closed position. Line valves shall be located in readily accessible areas of ducts and shafts, however care should to ensure safety to prevent danger from leakage. Line valve installation should be carried out as per HTM 2022/HTM 02-01 standards.
Area Line Pressure Medical Gas Alarm ( 4 gases)<br>SITC of Four channel microprocessor controlled alarm for pneumatic & vacuum services with Digital display of line pressure for all the services with factory calibrated pressure sensors. Color coded LED display of line pressure status (High-caution normal- caution-low) Audible Alarm for High & Low pressure condition. Test and Alarm Acknowledge (Mute) facility. (Alarm knowledge (mute) time span is programmable from 1 to 60 minutes). Protected programming facility of alarm limits. The electronic circuitry should be such that if the pressure / vacuum in the gas pipeline drops below the present limit, the equipment should give an audio-visual alarm. Visual alarm should remain active even after pressing of “Mute” button. It should come to normal condition only when gas pressure / vacuum return to normal level. Small and compact design. Mounted on a powder coated MS box. Nut & Nipples should be provided for connection with Pneumatic supply complete as required, all QA/QC should be furnished before Engineer (HLL) before installing the system.
Pressure Control - (1 to 7 bar)<br>SITC of 1-7 Bar pressure control in the pipeline system with necessary accessories and all mounting requirements. The control must be easy to operate and have provision for displaying line pressure with necessary cut of valve.
Vacuum regulator with suction bottle<br>SITC of Single piece wall mounted suction collection & regulation unit With jar capacity of 600 ml each shall be provided at each of the bed side. Jars would be made of autoclavable materials. The units shall be clamped neatly to the wall using suitable clamps
MINOR ELECTRICAL WORKS
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required2 X 4 sq. mm + 1 X 4 sq. mm earth wire
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required4 X 6 sq. mm + 2 X 6 sq. mm earth wire
Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.3 Module (100mmX75mm)
Supplying and fixing DP sheet steel enclosure on surface/ recess along with 25/32amps 240 volts "C" curve DP MCB complete with connections, testing and commissioning etc. as required.
Supplying and fixing TP sheet steel enclosure on surface/ recess along with 16/25/32amps 415volts "C" curve TP MCB complete with connections, testing and commissioning etc. as required.
Supply and installation of sheet steel, phosphatised and painted, dust and vermin proof enclosure of MCB DB including copper /brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/ isolator etc. fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall , making good the damages, colour washing etc. as required6 way (8+18) - double cover TPN vertical DB with provision for fixing 4P MCB / Isolator/ RCCB/ RCBO as incomer and SP/ TP MCB as outgoing (IP 42/43)
Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.3.5 core 25 sq mm with factory made clamp
Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured copper power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.4 core 6 sq mm with factory made clamp
Grand Cool Solutions
stage.html
html • 0.03 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .