Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Tender Value
₹34 L
EMD Value
₹68,000
Closing Date
1 Jan 2026, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE AF AMBALA
GE AF AMBALA
REPAIR/REPLACEMENT AND MAINT OF E/M INSTALLATION INCLUDING INTERNAL WIRING, FITTING OF BUILDING LIGHTS, EARTHING AND CONNECTED ITEMS AT AF STN AMBALA UNDER GE (AF) AMBALA
2025_MES_742826_1
GE AF/AMB-T-65/2025-26
Open Tender
Civil Works
Item Rate
180 days
GE AF AMBALA
ALL AS PER NIT AND TENDER DOCUMENTS
7 documents required · 7 mandatory
₹500
GE AF AMBALA
₹68,000
Yes
4 Dec 2025
4 Dec 2025
3 Jan 2026
4 Dec 2025
1 Jan 2026
18 Dec 2025
5 Dec 2025 - 11 Dec 2025
Taking down carefully old/unsv copper/alluminium any type of point wiring for one light, socket, fan, bell or power etc incl all fittings such as switches sockets, holders, light fittings, fan requlators, call bell etc and making good the disturbed surface of wall ceiling complete all as specified and directed.
One light point controlled by one way switch 5/6 amps.
S&F switch piano flush type 5/6 amps single pole one way complete all as specified and directed.
M&L for concealed type Point wiring with 1.5 Sqmm (nominal cross-sectional area) PVC insulated unsheathed single core multi stranded copper FRLS cable working voltage 1100 volts grade conforming to IS-694 with stranded copper conductor in including PVC conduit of adequate size having a wall thickness not less than 1.5 mm with all accessories (including cutting chases & making good the disturbed surface to its original specification) including 1.5 sq mm (nominal cross sectional area) PVC insulated unsheathed single core multistranded copper conductor FRLS cable as earth continuity conductor connected to main switches/DB's or common earth dolly complete all as specified and directed for the following :-
S&F ceiling rose, bakelite, surface type, 220/240 volts, three terminals complete all as specified and directed.
S & F deluxe fan Electronic regulator 120/280 volts AC 50 Hzs rotary step white/ivory finish complete all as specified and directed.
S&F switch socket combination 2 in 1, 6 pin 5/6 amps and 15/16 amps multipurpose, white/ivory finish flush non shutter non inter locking type complete all as specified and directed.
Taking down unsv switches/regulators/ceiling rose/lamp holder complete all as specified and as directed.
Taking down unsv FTL/sketch fitting of any type and capacity complete all as specified and as directed.
S&F LED light fittings 1 x 18/20 watts 230 Volt 6500K, IP-20, white poly carbonate body, in built surge protection 4KV, zero mercury content, complete with all accessories internally pre-wired and including connecting up with three core twisted flexible copper conductor cable up to cealing rose complete all as specified and directed.
S&F in repair MCB, Single pole, 5 to 32 amps, 240 volts, ‘C’ curve, 10 KA all complete as specified and as directed.
Supply, connecting & passing through pipe/duct, 660 volts grade, PVC insulated, flexible wire with multistranded copper conductor of cross sectional area 16 sqmm 3 core complete with & including all fixing & connecting accessories such as Copper lugs, nut, bolts, washer etc complete with and including taking down unsv wire all as specified and as directed.
Supply and laying in repair PVC insulated cable submersible flat copper 3 core 16Sqmm 1100 volt grade, complete all as specified and directed.
M & L for cement concrete (1:4:8) type C-2 (using 40mm graded mechanically crushed stone aggregate) 75mm thick as in sub base for floor, hard standing/paving etc complete all as specified and directed.
M & L for cement concrete (1:2:4) type C-2 (using 20mm graded mechanically crushed stone aggregate) 75mm thick as in paving/hardstandings/layingpanels including joints etc for floor finishing complete all as specified and directed.
M&L for Cleaning the vegetation including grass, bushes, small trees and all vegetation growth complete including digging out the root of bushes, small trees around the installations/sump/OH reservoir, valve chamber, including chamber etc filling the rough holes with earth, levelling the surfaces by removing all debris to a distance not exceeding 50m complete all as specified and directed.
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.22 MB
65TenderPages.pdf
Tender Documents • 0.81 MB
BOQ_831807.xls
BOQ • 0.39 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .