Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹7.1 LAccepted-AOC | L1 | Accepted-AOC L1 | |
| 2 | Rejected-Technical | - | Rejected-Technical L2 |
Tender Value
₹7.1 L
EMD Value
₹17,760
Closing Date
23 Feb 2022, 6:00 pmClosed
Assistant Engineer
Assistant Engineer, LIDEW Subdivision, Pazhayannur
Pazhayannur Block panchayath 2021-22 Project no.177/22 Construction of Building for Dialysis centre R O unit in Chelakkara Taluk Hospital
2022_LSGD_474827_2
05/2021-22/AE
Open Tender
Civil Works - Buildings
Item Rate
Pazhaynnur
Please refer Tender documents.
7 documents required · 7 mandatory
₹1,430
Yes
₹17,760
Yes
11 May 2022
15 Feb 2022
25 Feb 2022
15 Feb 2022
23 Feb 2022
15 Feb 2022
Amount
R O Unit
15.17.2 : Dismantling steel work in single sections including dismembering and stacking within 50 metes lead in:Channels, angles, tees and flats
15.28.1 : Dismantling roofing including ridges, hips, velleys and gutters etc., and stacking the material within 50 metres lead of :G.S. Sheet
50.6.1.5 : Solid block masonry using pre cast solid blocks ( Factory made) of size 30x20x20cm or nearest available size confirming to IS 2185 Part I of 1979 for super structure up to floor two level thickness 20cm and above in: CM 1:6 ( 1 cement : 6 coarse sand) etc complete
4.2.3 : Providing and laying cement concrete in retaining walls, return walls, walls ( any thickness) including attached pilasters, columns, piers, abutments, pillars, posts, struts,buttresses, string or lacing courses, parapets, coping, bed blocks, anchor blocks, plain window sills, fillets, sunken floor, etc. up to floor five level, excluding the cost of centering, shuttering and finishing:1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size)
5.2.2 : Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. up tot floor five level excluding cost of centering, shuttering, finishing and reinforcement :1:1.5:3( 1 cement : 1.5 coarse sand : 3 graded stone aggregate 20 mm nominal size)
5.3 : Reinforced cement concrete work in beams, suspended floors, roofs, having slope up to 15<sup>0</sup> landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases up to floor five level excluding the cost of centering, shuttering, finishing and reinforcement, with1:1.5:3 (1 cement : 1.5 coarse sand (Zone III) : 3 graded stone aggregate 20 mm nominal size).
5.9.5 : Centering and shuttering including strutting, etc. and removal of form for:Lintels, beams, plinth beams, girders bressumers and cantilevers
5.9.6 : Centering and shuttering including strutting, etc. and removal of form for:Columns, Pillars, Piers, Abutments, Posts and Struts
5.22.6 : Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth levelThermo - Mechanically Treated bars of grade Fe-500D or more
13.1.1 : 12 mm cement plaster of mix:1:4 ( 1 cement : 4 fine sand)
od1652751/2021_2022 : Supplying and fixing PRESSED STEEL WINDOW and VENTILATORS of standard pattern with frames as per profile of sections 82x 62mm embossed sheet shutter 50x 20mm special channel (reverse and beading) shutter,12mm dia rod,25 x 5mm flat with 75mm ss hinges,50mm ss hook,125mm ss stay and handle for windows with section 105 x60mm using 16 G (1.2MM THICK CRCA)sheet and shutter made of sections 75 *30cm outer styles and horizontal members and then inserted with stiffened sheet 26 CR with zincromat primer
10.16.1 : Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete.Hot finished welded type tubes
od1652752/2021_2022 : Roofing with GI hard color powder coated traffored sheet 0.35 mm thick or nearest available thickness ,with overlaps up to 150 mm , GI hooks,nuts,or plain bitumen washers etc all complete.
13.43.1 : Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface:Water thinnable cement primer
13.61.1 : Painting with synthetic enamel paint of approved brand and manufacture to give an even shade:Two or more coats on new work
FAIZ M M
Bidder Name
m.a.muhammed
FAIZ M M
stage.html
html • 0.03 MB
tech_eval.pdf
fin_eval.pdf
aoc.PDF
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .