Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹56.2 LAdmitted-Finance VILL P O MIRAGPUR DISTT SAHARANPUR 247554 U P | SAHARANPUR | UTTAR PRADESH | 247554 | ₹56.2 L | L1 | Admitted-Finance |
| 2 | L2₹65.5 L+₹9.3 L (16.5%)Admitted-Finance D 89 SHASTRI NAGAR MEERUT UTTAR PRADESH PIN 250004 | MEERUT | UTTAR PRADESH | 250004 | ₹65.5 L+₹9.3 L (16.5%) | L2 | Admitted-Finance |
| 3 | L3₹74.6 L+₹18.3 L (32.6%)Admitted-Finance | ₹74.6 L+₹18.3 L (32.6%) | L3 | Admitted-Finance |
| Sl No | Description | Qty | Unit | MOHAN LAL GUPTA L2 | Ms dev associates L3 | sath sahib associates L1 |
|---|---|---|---|---|---|---|
| 1.00 | Demolition of existing roof treatment i.e APP membrane incl cement screed, brick tiling incl mud mortar or lime concrete and open up RCC roof slab including picking, sweeping cleaning with wire brush and washing down with Removal of existing roof treatment i.e APP membrane, brick tiling incl mud mortar and open up RCC roof slab including picking, sweeping cleaning with wire brush and washing down with water to remove dust, dirt to get surface free of laitance , scales, oil or any other loose material complete all as specified and directed.Note :- (a) The work is required to be carried out at non-accessible roof for double storey . The contractor shall make arrangement of scoffolding,safety & security of workers and arrangement for approach to roof.
(b) The rates quoted shall deemed to be included for these items. | 4,130 | Sqm | 20 ₹82,600 Lowest | 20 ₹82,600 Lowest | 40 ₹1,65,200 |
| 2.00 | M&L PCC 1:2:4 40 mm thick type B-0 (using 12.5 mm graded stone agg) mixed with liquid water proofing compound (mixed as per manufacturer direction ) and finishing the surface even and smooth without using extra cement as in roof paddingto receive roof treatment complete all as specified and directed.
Note :-
1. Liquid water proofing compound will be measured and paid seperately.
2. The work is required to be carried out at non-accessible roof . The contractor shall make arrangement of scaffolding,safety & security of workers and arrangement for approach to roof . The rates quoted shall deemed to be included for these item. | 4,130 | Sqm | 200 ₹8,26,000 Lowest | 232 ₹9,58,160 | 200 ₹8,26,000 Lowest |
| 3.00 | M&L for PCC (1:2:4) type B-0, using 12.5mm graded stone aggregates, as in concrete angle-fillets with a radiaus of 75 mm shall be provided at junctions between roofs, floor and vertical faces of walls (parapet, pillar for water tank staging and sunken floor) around obstacles such as pipes, chimney stacks etc. and other similar situation to ease up about corners mixed with integral water proofing compound as per manufactur direction )
Note :- Liquid water proofing compound (WPC) will be measured and paid seperately. | 9 | Cum | 4,000 ₹36,000 Lowest | 6,000 ₹54,000 | 5,000 ₹45,000 |
| 4.00 | Supply only WPC integral water proofing compound (Liquid type) complete all as specified and directed. | 214.98 | Ltr | 100 ₹21,498 Lowest | 150 ₹32,247 | 200 ₹42,996 |
| 5.00 | M&L for one coat of cement slurry admixed with acrylic bonding compound SBR Latex liquid polymer (slurry will be prepared as per manufacturer direction) as to be used for bonding of new concrete/ mortar to old surface.
Note :- (i)The work is required to be carried out at non-accessible roof. (ii)The contractor shall make arrangement of scaffolding,safety & security of workers and arrangement for approach to roof .(iii) The rates quoted shall deemed to be included for these item. | 4,130 | Sqm | 100 ₹4,13,000 | 90 ₹3,71,700 | 50 ₹2,06,500 Lowest |
| 6.00 | M&L for water proofing treatment to non-accessible roof slab with APP based modified polymeric membrane as per manufacturer’s instructions with following course of description below :-
(a) Applying a priming coat of bituminious primer @ 0.30 kg/sqm till the surface is properly impregnated.
(b) Providing APP based 5 layer polymeric membrane minimum weighing 3.6Kg/ Sqm and minimum 3mm thick reinforced with polyester non-woven fabric (weight not less than 150 gms/sqm) centre core, laid on primed surface by forced applications as per the manufacturer's instructions with side over lap of 75 mm and end overlap of 100 mm. All overlap joints shall be sealed thoroughly by thermo fusing both the membrane layer (torching overlap by propane or butane gas torch ) and sealing it with the help of hot trowel. The overlap joints shall be made as a monolithic layer
(c) Apply two coat of bituminous aluminium paint @ 0.20 Kg/Sqm over APP membrance
Note :-
1. The work of water proofing treatment shall be got executed through authorised applicator of the manufacturer only.
2. The work is required to be carried out at non-accessible roof slab for double storeyed. The contractor shall make arrangement of scaffolding, safety and security of workers and arrangement for approach to roof. The rates quoted shall deemed to be included for these items. | 4,130 | Sqm | 650 ₹26,84,500 | 585 ₹24,16,050 | 400 ₹16,52,000 Lowest |
| 7.00Disconnecting and dismantling of water storage tank and removing from the site of following capacity of tank complete all as specified and as directed:- | ||||||
| 7.01 | Capacity exc 500 Ltr but not exc 1000 Ltr | 48 | Each | 100 ₹4,800 Lowest | 150 ₹7,200 | 500 ₹24,000 |
| 8.00S&F rotational moulded polyethylene water storage tank, double layer construction, white in colour ISI mark (cylindrical vertical with closed top) hoisted and fixed in position with and including 20 mm dia GI pipe medium grade washout pipe 450 mm long with plug and 20 mm dia GI pipe medium grade overflow pipe 600 mm long with fittings, 20 mm dia ball valves high pressure of PTMT with epoxy coated aluminium rod & high density plastic ball screwed for iron pipe and fixed. (Minimum weight 20mm-210gms). of following capacity of tank complete all as specified and as directed:- | ||||||
| 8.01 | Capacity 1000 Ltrs | 48 | Each | 8,200 ₹3,93,600 Lowest | 10,000 ₹4,80,000 | 11,000 ₹5,28,000 |
Tender Value
₹69.1 L
EMD Value
₹1.3 L
Closing Date
24 Aug 2026, 6:00 pmClosed
CWE Hills Dehradun
HQ CWE Hills Mall Road Dehradun Cantt 248003
SPECIAL REPAIR TO ROOF TREATMENT OF CERTAIN OFFRS MD ACCN AT RAIWALA MIL STN
2026_MES_777927_1
86482/RWL/E8
Open Tender
Civil Works
Item Rate
150 days
AGE (I) Raiwala
Class C Cat a (i)
6 documents required · 6 mandatory
₹1,000
Yes
AGE (I) Raiwala
₹1.3 L
Yes
10 Sept 2026
11 Jul 2026
1 Sept 2026
11 Jul 2026
24 Aug 2026
11 Aug 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Demolition of existing roof treatment i.e APP membrane incl cement screed, brick tiling incl mud mortar or lime concrete and open up RCC roof slab including picking, sweeping cleaning with wire brush and washing down with Removal of existing roof treatment i.e APP membrane, brick tiling incl mud mortar and open up RCC roof slab including picking, sweeping cleaning with wire brush and washing down with water to remove dust, dirt to get surface free of laitance , scales, oil or any other loose material complete all as specified and directed.Note :- (a) The work is required to be carried out at non-accessible roof for double storey . The contractor shall make arrangement of scoffolding,safety & security of workers and arrangement for approach to roof.
(b) The rates quoted shall deemed to be included for these items. | 4,130 | Sqm | 48.5 | ₹2,00,305 |
| 2 | M&L PCC 1:2:4 40 mm thick type B-0 (using 12.5 mm graded stone agg) mixed with liquid water proofing compound (mixed as per manufacturer direction ) and finishing the surface even and smooth without using extra cement as in roof paddingto receive roof treatment complete all as specified and directed.
Note :-
1. Liquid water proofing compound will be measured and paid seperately.
2. The work is required to be carried out at non-accessible roof . The contractor shall make arrangement of scaffolding,safety & security of workers and arrangement for approach to roof . The rates quoted shall deemed to be included for these item. | 4,130 | Sqm | 195 | ₹8,05,350 |
| 3 | M&L for PCC (1:2:4) type B-0, using 12.5mm graded stone aggregates, as in concrete angle-fillets with a radiaus of 75 mm shall be provided at junctions between roofs, floor and vertical faces of walls (parapet, pillar for water tank staging and sunken floor) around obstacles such as pipes, chimney stacks etc. and other similar situation to ease up about corners mixed with integral water proofing compound as per manufactur direction )
Note :- Liquid water proofing compound (WPC) will be measured and paid seperately. | 9 | Cum | 125 | ₹1,125 |
| 4 | Supply only WPC integral water proofing compound (Liquid type) complete all as specified and directed. | 214.98 | Ltr | 30.25 | ₹6,503.14 |
| 5 | M&L for one coat of cement slurry admixed with acrylic bonding compound SBR Latex liquid polymer (slurry will be prepared as per manufacturer direction) as to be used for bonding of new concrete/ mortar to old surface.
Note :- (i)The work is required to be carried out at non-accessible roof. (ii)The contractor shall make arrangement of scaffolding,safety & security of workers and arrangement for approach to roof .(iii) The rates quoted shall deemed to be included for these item. | 4,130 | Sqm | 143 | ₹5,90,590 |
| 6 | M&L for water proofing treatment to non-accessible roof slab with APP based modified polymeric membrane as per manufacturer’s instructions with following course of description below :-
(a) Applying a priming coat of bituminious primer @ 0.30 kg/sqm till the surface is properly impregnated.
(b) Providing APP based 5 layer polymeric membrane minimum weighing 3.6Kg/ Sqm and minimum 3mm thick reinforced with polyester non-woven fabric (weight not less than 150 gms/sqm) centre core, laid on primed surface by forced applications as per the manufacturer's instructions with side over lap of 75 mm and end overlap of 100 mm. All overlap joints shall be sealed thoroughly by thermo fusing both the membrane layer (torching overlap by propane or butane gas torch ) and sealing it with the help of hot trowel. The overlap joints shall be made as a monolithic layer
(c) Apply two coat of bituminous aluminium paint @ 0.20 Kg/Sqm over APP membrance
Note :-
1. The work of water proofing treatment shall be got executed through authorised applicator of the manufacturer only.
2. The work is required to be carried out at non-accessible roof slab for double storeyed. The contractor shall make arrangement of scaffolding, safety and security of workers and arrangement for approach to roof. The rates quoted shall deemed to be included for these items. | 4,130 | Sqm | 38.3 | ₹1,58,179 |
| 7Disconnecting and dismantling of water storage tank and removing from the site of following capacity of tank complete all as specified and as directed:- | |||||
| 7.01 | Capacity exc 500 Ltr but not exc 1000 Ltr | 48 | Each | 225.7 | ₹10,833.6 |
| 8S&F rotational moulded polyethylene water storage tank, double layer construction, white in colour ISI mark (cylindrical vertical with closed top) hoisted and fixed in position with and including 20 mm dia GI pipe medium grade washout pipe 450 mm long with plug and 20 mm dia GI pipe medium grade overflow pipe 600 mm long with fittings, 20 mm dia ball valves high pressure of PTMT with epoxy coated aluminium rod & high density plastic ball screwed for iron pipe and fixed. (Minimum weight 20mm-210gms). of following capacity of tank complete all as specified and as directed:- | |||||
| 8.01 | Capacity 1000 Ltrs | 48 | Each | 1,113.4 | ₹53,443.2 |
stage.html
html • 0.03 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.33 MB
BOQ_871250.xls
BOQ • 0.27 MB
Tender86482.pdf
Tender Documents • 1.41 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .