Loading…
Loading…
Tender Value
₹477 Cr
EMD Value
₹4.8 Cr
Closing Date
28 Jul 2026, 6:00 pm
Directorate of Archaeology & Museum, Gandhinagar
Selection of Construction and Management Agency (CMA) for Construction, Operations & Maintenance Services of the Gujarat Vandana Museum at Ekta Nagar, Narmada District, Gujarat
321350
2026/Ekta Nagar
Open
Civil - All
Gandhinagar
4 documents required · 4 mandatory
₹18,000
Director, Directorate of Museums
₹4.8 Cr
6 Jul 2026
6 Jul 2026
6 Jul 2026
28 Jul 2026
6 Jul 2026
GUJARAT VANDANA MUSEUM, GUJARAT (GVM)
BILL OF QUANTITIES
SR NO PARTICULARS TOTAL AMOUNT
2 STRUCTURAL WORK 0
3 MASONRY WORK 0
4 WATERPROOFING WORK 0
5 FLOORING WORK 0
8 ROOFING & CEILING 0
9 FINISHING WORK 0
10 ALUMINIUM WORK 0
11 PLUMBING WORKS 0
12 FIRE FIGHTING WORKS 0
13 ELECTRICAL WORKS 0
14 ELV & ICT WORKS 0
15 HVAC WORKS 0
16.1 HORTICULTURE 0
16.2 IRRIGATION 0
16.3 WATER BODIES 0
18 DEMOLITION & DISMANTLING WORK 0
19 BARRICADDING WORK 0
20 MISCELLANEOUS WORK 0
21 KITCHEN EQUIPMENT 0
22 BORE WELLS 0
24 ACOUSTICS & AV WORK 0
25 SIGNAGE & WAY-FINDING 0
26 SPECIAL LIGHTING 0
27 FURNITURE, FIXTURE & EQUIPMENT 0
SUB TOTAL - BUILDING CONSTRUCTION WORKS 0
Add : GST 18% 0
TOTAL OF BUILDING CONSTRUCTION WORKS 0
23 INTERIM MAINTENANCE PERIOD 0
24. OPERATION & MAINTENANCE for 5 YEARS 10% 0
SUB TOTAL - OPERATION & MAINTENANCE 0
Add : GST 18% 0
TOTAL OF OPERATION & MAINTENANCE 0
Amount in words -
SR. NO. PARTICULARS UNIT RATE TOTAL QUANTITY TOTAL AMOUNT
Work and rate shall include the following:
A. Setting out works, erecting profiles, etc.
B. Site clearance such as cleaning of shrubs, brushwood, small trees not exceeding 30 cm in girth measured at one meter above ground.
C. Forming (or leaving) DEAD MEN or TELL-TALES in borrow pits and their removal after measurements.
D. Forming or leaving steps in sides deep excavation and their removal after measurements.
E. Excavation for insertion of planking and strutting.
F. Removing slips or falls in excavation.
G. Dewatering (bailing or pumping out water in excavations from rains, sub-soil water, etc.)
H. Slinging or supporting pipes, electric cables, etc. met during excavation or carrying out of any item of work.
I. Dressing, trimming of sides, leveling or grading and ramming of bottoms.
All items of excavation, filling, etc. shall be carried out in dry site only. The contractor to note that dewatering wherever required or ordered by the RE shall be part of the respective item and the contractor must make necessary allowance in his quoted rates. No additional cost on account of dewatering of any nature and for any reason shall be payable throughout the contract.
Anti-termite treatment shall be measured in sq m once for the actual plinth area in the plan. The rate will include,
· Method of working as per the approved manufacturer
· Number of operations required
· Application at various levels and stages
· Guarantee for 10 years in approved form
Carting away all surplus excavated material outside the plot area including loading, transportation, unloading etc. complete. (Volume will be measured on compacted basis, on the basis of approved excavation quantities and filling quantities.
Allowance for voids shall be included in quoted rates only. Contractor should locate suitable area for dumping the material at his own cost.
1.1 Excavation for foundation upto 1.5 m depth including sorting out and stacking of useful materials and disposing off the excavated stuff upto 50 Meter lead.(A) Loose or soft soil Cum 43,913.00 0
1.2 Excavation for foundation for depth from 1.5 m to 3.0 m including sorting out and stacking of useful materials and disposing off the excavated stuff upto 50 Meter lead.(B) Dense or Hard soil Cum 14,627.00 0
1.4 Excavation for foundation for depth from 3.0 m to 5.0 m including sorting out and stacking of useful materials and disposing off the excavated stuff upto 50 Meter lead.(B) Dense or Hard soil Cum 10,728.70 0
1.5 Excavation for foundation for depth from 3.0 m to 5.0 m including sorting out and stacking of useful materials and disposing off the excavated stuff upto 50 Meter lead.(D) Soft rock not requiring Blasting Cum 1,813.30 0
1.6 Excavation for foundation depth more than 5.0 m for excavation for foundation including sorting out and stacking of useful materials and disposing off the excavated stuff upto 50 m lead.(D) Soft rock not require Blasting Cum 5,717.60 0
1.7 Excavation for foundation depth more than 5.0 m for excavation for foundation including sorting out and stacking of useful materials and disposing of the excavated stuff upto 50 m lead.(E) Hard Rock Cum 1,429.40 0
1.8 Add extra for Disposing off the excavated stuff of above items for lead of (A) 50 m to 200 m Cum 70,000.00 0
1.12 Filling available excavated earth (excluding rock) in trenches. plinth, sides of foundations etc. in layers not exceeding 20 cm. in depth consolidating each disposited layer by ramming and watering. Cum 29,023.00 0
1.13 Filling in foundation and plinth with murrum or selected soil in layers of 20cm. thickness including watering, ramming and consolidating etc. complete. Cum 7,892.00 0
1.14 Anti-Termite System:Providing and laying of permanent piping technology anti-termite treatment before flooring work by installing LLDP (Low linear density polyethylene) tube of 8 mm O.D. & 6.4 mm 1.D. with inbuilt pressure compensation chip every 30 cm interval in the tube, having working pressure of 2 Kg/cm2 and release rate of 1.9 Itr/hour fixed by P-clips and nails. The LLDP pipe shall be installed at the entire periphery of the building and at internal network of building at a depth of 20 to 200 mm under floor at every 2 to 3 mtr. c/c distance (adjusted as per building layout ) & Ends of loop pass through a PVC elbow of minimum 32 mm ID at junction box of wall and floor level, entering into a steel reinforced grooved flexible pipe of minimum 22 mm ID leading into junction box and the loops shall terminate in junction boxes & test every junction during injecting chemicals for termite control treatment. The anti termite chemical Imidacloprid 30.5% SC -Sq.mt 133.00 mix as per IS-6313 (part III) shall be injected by the pressure pump diluted with water @ 10.5 ml/5 ltr of water at the rate of 2 Kg/sq.cm @ 5 Ltr/SMT. The contractor shall submit approved line plan for piping system and junction boxes dully approved by Engineer-in-Charge with bond of 10 year warranty.(i)Anti Termite chemical injected area (Chemical injecting incl. labour cost) (Only plinth area at Ground level shall be measured for payment) Sqm 10,847.00 0
1.17 Construction of granular sub-base by providing close graded Material conforming to specifications, mixing in a mechanical mix plant at OMC, carriage of mixed material by tippers to work site, for all leads & lifts, spreading in uniform layers of specified thickness with motor grader on prepared surface and compacting with vibratory power roller to achieve the desired density, complete as per specifications and directions of Engineer-in-Charge.
a With material conforming to Grade-I (size range 75 mm to 0.075 mm) having CBR Value-30 Cum 8,671.00 0
1.19 Providing and Filling with Murum in layers to required depths as directed, including watering, ramming and compacting dry density, including carrying out Laboratory 'Proctor Density' Test, etc. complete as directed by site incharge.( Consolidated thickness will be considered for payment.)
a Murum available at site Cum 81.00 0
TOTAL OF EARTH WORK 0
2. STRUCTURAL WORK
All concrete work shall be design mixed of the grade specified on drawing
The rates for PCC/RCC work shall include the following:
A. All materials with wastage & All labour. All test on materials and cube testing or any other testing as instructed by the RE / Structural Consultant as per IS.
B. All architectural effects like chases, ledges, moulds, grooves, chamfers, brackets etc. shall be created by using approved form work including making special size mould, staging arrangement, etc.
C. Work at all depths, heights and leads.
D. If different grades of concrete are used at junctions, spillover of richer concrete required from practical considerations shall be included in the rate.
E. The concrete shall include ingredient material, mixing, transporting, hoisting to any height and lowering to any depth, pumping (as detailed), pouring or laying, consolidating, leaving pockets, holes, conduits and protecting them till the next operation or completion of work, hacking the surface to provide key for further work including cleaning, wetting, surface curing, etc. and preparing construction joints. The price built-up shall include the loading, unloading, weighing and storing of cement in good conditions.
F. Admixtures as required and should conform to IS 9103.
G. Water proofing compound, as required.
H. Cement grouting with non shrink grouting compound
I. Dewatering to keep area dry.
J. The contractor shall provide and maintain laboratory at site equipped as under and staffed with qualified technicians.
· A set of standard sieves
· Measuring cylinders
· Adequate number of standard cube moulds
· Weighing machines measuring to 10 grams and upto 50 Kg.
· Oven or other apparatus to dry aggregates.
· Concrete cube testing m/c, 140T capacity, electrically operated.
2.1 Providing and laying cement concrete 1:4:8 (1- Cement : 4- Coarse sand : 8- Graded Brick bats aggregate 40mm normal size) and curing complete excluding cost of formwork in (A) Foundation and Plinth Cum 2,136.00 0
2.3 Providing and laying in position Ready Mixed M-30 grade concrete for reinforced cement conctere work , using cement content as per approved Design Mix manufactured in fully automatic batching plant and transported to site of work in transit mixer for a lead up to 10 kms having continuous agitated mixer, manufactured as per mix design of specified grade for reinforced cement concrete work including pumping of R.M.C. from transit mixer to site of laying, excluding the cost of centering shuttering finishing and reinforcement including cost of admixtures in recommended proportions as per IS: 9103 to accelerate/ retard setting of concrete, improve workability without impairing strength and durability as per direction of the Engineer - in - charge. Without Fly Ash (Min cement level as per latest IS 456 shall be maintained) (Cement level 475 kg ) Cum 1,370.00 0
2.5 Providing and laying in position Ready Mixed M-40 grade concrete for reinforced cement conctere work , using cement content as per approved Design Mix manufactured in fully automatic batching plant and transported to site of work in transit mixer for a lead up to 10 kms having continuous agitated mixer, manufactured as per mix design of specified grade for reinforced cement concrete work including pumping of R.M.C. from transit mixer to site of laying, excluding the cost of centering shuttering finishing and reinforcement including cost of admixtures in recommended proportions as per IS: 9103 to accelerate/ retard setting of concrete, improve workability without impairing strength and durability as per direction of the Engineer - in - charge. Without Fly Ash (Min cement level as per latest IS 456 shall be maintained) (Cement level 575 kg ) Cum 26,984.00 0
2.6 Providing and laying plum concrete course in plain cement concrete M-15 and evenly distributed plums of basalt or trap of size 160 mm and above up to any reasonable size to a maximum limit of 30% by volume of concrete including mechanically vibrating and compacting, centering etc. complete. ( No plums shall be allowed to be projected/protruded with in 150mm from top level of plum concrete). Cost towards formwork shall be included in the quoted rate. Cum 1,000.00 0
2.8 Providing TMT Bar FE 500D reinforcement for R.C.C. work including bending, binding and placing in position complete upto floor two level Kg 5,745,897.00 0
2.9 Expansion Joint Covers
a ROOF SLAB TYPE-1 Providing & fixing of earthquake-resistant Series for Roof Top Covers 150 mm for Expansion Joints having Aluminum Plate at upper predrilled mounting brackets and flexible rubber support. The system should be able to perform as per the Joint size, having desired movement. This Solid all metal roof top cover should be maintenance free, hard wearing and long-lasting model for roof area. This design minimizes noise emission in windy conditions. This model has three-dimensional movement absorption. Also has vertical movement with total 100 percent movement. For Precise Transitions the system should be installed by the way of positive connection between each single length by the way of connecting pins that should ensure a flat level and precise transition. Rmt 19.00 0
b ROOF SLAB TYPE-2 Providing & Fixing earthquake-resistant Series Model -RTC Corner Profile for Roof Top Covers for 150MM Expansion Joints, the having Aluminum Plate at upper predrilled mounting brackets and flexible rubber support. The system should be able to perform for 150mm of Joint size, having desired movement This is Solid all metal roof top cover should be maintenance free, hard wearing and long lasting model for roof area. This design minimizes noise emission in windy conditions. This model has three dimensional movement absorption. For Precise Transitions the system should be installed by the way of positive connection between each single length by the way of the connecting pins that should ensure a level and precise transition. Approved Make Expansion Joint. Rmt 57.00 0
c ROOF SLAB TYPE-3 Supplying and Installation Flameline Expansion Joint system with FSL-173 Corner Profile, especially design for roof area to accommodate structural movement and ensure complete watertight. Covers for Metal Series, Floor to Corner Model, for 150mm Expansion Joints Aluminum Covers Profiles for Top Finish, having a Hard Wearing, Maintenance Free, long Lasting design having Smooth Surface. The Surface of the Exp. Joint Covers should have Sirated Surface, which should ensure to have a good Skid Resistance so that it avoids any kind of Slippages when used. The design of the Exp. Joint Cover System should be such that it should avoid any accumulation of dirt. The Exp. Joint Cover should have an Articulated Telescope Design so as to accommodate the movements in 3 direction. It should also accommodate a Vertical Movement of 10 mm. The surface of the system should be in the Mill finish. The Total Visible width of the profile should not be 173 mm & the installation Height can be of 35 mm. The system can be used for standard Rolling Loads of 1-2 Cars or Cart Wheel Loads if required. The system should have ASTM1399 E IV certification. Provision of Flameline 100% in the Joint System to have watertight joint is mandatory on the motherslab. The Sealing Strip system is specifically developed compound with ensure to absorb the Three Dimensional movement having a Total Width of 420mm. The material consists of the elastic material Butyl-Elastomer and Very high long-term heat resistance (up to +90° C)/ Very high flexibilty at low temperatures (up to –40° C)/Water pressure up to 0.5 bar/Overall resilience against chemicals:/Very good against alkali, diluted acids and saline solutions/Excellent against vapour/Very good resilience against polar solvents like alcohol/and ketone. The Sealing Strip should have the properties for sealing on the Bitumen sheets, Epoxy/PU Adhesive on Concrete & Metal. The both the side Ends should have the Protruding Fabric which should enable for the Perfect bonding/connecting with Bitumen / Epoxy/PU.Requirement all as per the manufactures design and as approved by the Engineer-in-Charge. Rmt 131.00 0
d WALL TYPE-1 (INTERNAL WALL) Supply and installation Symmetric metal wall and ceiling cover is designed for interior and Exterior applications where low-maintenance or tamper resistant applications are desired. The free-floating aluminium centre plate spans the joint and slides between retainer assemblies to allow for required movement. The cover can be anodised or powder coated in any RAL colour. Extrusion shall be of ASTM 6063 T66 standard. Can be used in a variety of wall construction including flush finish in drywall applications also. No exposed fasteners for tamper proof application. For exterior use of water barrier EPDM membrane must be installed below WP profile. Rmt 91.00 0
e WALL TYPE-2 (EXTERNAL WALL) Supply and installation Symmetric metal wall and ceiling cover is designed for interior and Exterior applications where low-maintenance or tamper resistant applications are desired. The free-floating aluminium centre plate spans the joint and slides between retainer assemblies to allow for required movement. The cover can be anodised or powder coated in any RAL colour. Extrusion shall be of ASTM 6063 T66 standard. Can be used in a variety of wall construction including flush finish in drywall applications also. No exposed fasteners for tamper proof application. For exterior use of water barrier EPDM membrane must be installed below WP profile. Rmt 123.00 0
f FLOOR TYPE-1 Providing & Fixing of the full Metal SEISMIC PAN JOINT (SPJ) System, for Expansion Joints All Aluminium Covers Profiles, having a Hard Wearing, Maintenance Free, long-Lasting design with no Shrink seal and no gasket with straight 90-degree Pan design to take 90 Degree of cut stone. The 90 degrees pan flange and side wall must be single extrusion to maintain smooth and synchronised movement of pan without any hurdle. The profile should be flushed with floor finish once installed. The Exposed Surface of the Exp. Joint Covers should have Micro Serrated Surface, which should ensure to have a good Skid Resistance so that it avoids any kind of Slippages when used. These side flanges should slide smoothly on side frame and must have single piece extrusion with pan side frame to ensure smooth movement. The Exp. Joint Cover should have a Seismic and Articulated Telescope Design so as to accommodate the movements in 3 directions. The turn bar must have 2-part assembly to provide vertical movement. It should also accommodate a Vertical Displacement and Thermal Movement of +/-20mm. The surface of the system should be in Mill finish. The Total Visible width on each Micro Serrated side will be 65mm in the form of flange to accommodate thermal movement & the installation Height will be 60 mm. The mounting brackets will be predrilled. The depth of Pan infill will be 30mm.The system can be used for standard Rolling Loads of 1-2 Cars or Cart Wheel Loads, must be FEM Stress tested by Design load (Cleaning Machine), Wheel load: 2,5 KN – Wheel contact patch: 10x1,0cm, qd=2500 x 1,5/(100x10) = 3,75 MPa. The system must have been tested for movement as per ASTM E 1399-class IV certification. The extrusion should be as ASTM 6063 T66 standards. For Precise Transitions the factory supplied slid-in connection pins should be used during the installation of the cover system. The Exp. Joint Covers/Profile shall be supplied in 3 mt. Cut Length. Rmt 42.00 0
g FLOOR TYPE-2 Providing & Fixing Floor to Corner for 150mm mm Expansion Joints, the having Solid All Metal Expansion Joint Cover. Maintenance- Free, Hard wearing and Long-Lasting, Non-Shrink Seal. The cover must be design in such a way that there should be aluminum flange in the sides and no requirement of any gasket or sealant should be there. The profiles are provided with 90° Vertical Side Walls. There Is no diagonal Cuttings of Stoneware necessary. The Exp. Joint System have three-dimensional movement absorption, easy to install with optimized design allows for easy and safe installation of the centering bar. Connection pins to ensure even installation with respect to both, height and width. The system must have tested for movement as per ASTM E 1399/ ASTM 1399 M, class IV certification. The extrusion should be as ASTM 6063 T66 standards. The Exp. Joint Covers/Profile shall be supplied in 3 mt. Cut Length. Provision of Moisture Barrier Membrane in the Joint System to have watertight joint is mandatory requirement all as per the manufactures design and as approved by the Engineer-in-Charge. Rmt 61.00 0
h FLOOR TYPE-3 Providing & fixing of the Covers for Interior Metal Series, Floor to Floor Model, for 150 mm Expansion Joints Aluminum Covers Profiles, having a Hard Wearing, Maintenance Free, and long lasting design. The surface of the Exp. Joint Covers should have Serrated Surface for Skid Resistance and should be ADA Compliant. The design of the Exp. Joint Cover System should be such that it should avoid any accumulation of dirt. The Exp. Joint Cover should have an Articulated Telescope Design so as to accommodate the movements in 3 directions both Horizontal & vertical movement. The system should be in 6063 alloy in Mill finish. The system can be used for standard pedestrian load. The side profile should have a MULTI HOLE mounting bracket allowing for secure fixing and Flexible anchoring and excellent bonding with given slab surface/masonry/epoxy bedding. For Precise Transitions the factory supplied slid-in connection pins should be used during the installation of the cover system. Rmt 35.00 0
i FLOOR TYPE-4 Providing & Fixing Covers for Interior Metal Series, Model - FSL 113, Floor to Wall Corner Model, for 100 mm Expansion Joints Aluminum Covers Profiles, having a Hard Wearing, Maintenance Free, long Lasting design. The Surface of the Exp. Joint Covers should have Serrated Surface for Skid Resistance and should be ADA Compliant. The design of the Exp. Joint Cover System should be such that it should avoid any accumulation of dirt. The Exp. Joint Cover should have an Articulated Telescope Design so as to accommodate the movements in 3 directions. The total Horizontal Movement should be 45 mm (-/+ 22.5 mm). It should also accommodate a Vertical Movement of 10 mm. The system should be in 6063 alloy in Mill finish and the total exposed surface of the profile should not be more than 113 mm (+/- 5 mm) & the installation Height can be of 20/35/50 mm. The system can be used for standard Rolling loads of private Cars or Cart wheel loads. The side profile should have a MULTI HOLE mounting bracket allowing for secure fixing and Flexible anchoring and excellent bonding with given slab surface/masonry/epoxy bedding. For Precise Transitions the factory supplied slid-in connection pins should be used during the installation of the cover system Rmt 37.00 0
j WALL TYPE-3 (INTERNAL) Providing & Fixing Wall and Ceiling Expansion joint Covers, for 30mm to 350 mm Expansion Joints having Flexible High Quality Electromagnetic Inserts to accommodate movements. The Inserts should be Hard Wearing & temperature resistance (- 30 C to + 120 C Degree). Expansion Joint covers/ Profile insert should have a double protection from water due to its double sliding special Foldable Insert that can be installed in continuation length up to 50 RMT. The insert must be wieldable if required to connect two pieces of inserts. The height will be 20mm to accommodate surface material like plaster, gypsum, false ceiling etc. The Side Profile should have a MULTI HOLE mounting bracket allowing for secure fixing and Flexible anchoring and excellent bonding with given slab surface/masonry/epoxy bedding. Rmt 301.00 0
Form work shall be carried out as detailed in technical specification.
a) All formwork shall be fair face finished with using plywood/ Steel panels as directed by RE.
b) Exposed form work where specified shall be for Architectural finish and shall create required architectural features with the use of specially designed forms.
Form work shall be measured and paid separately except for PCC items or if stated specifically in Schedule of Rates. The quoted rate shall be applicable for all working conditions and at all heights, depths or lifts specified in the BOQ. The rate shall include the cost of materials and labour for various operations involved. The rate shall include the following, in addition to the “Measurement / Rate“ as mentioned in Technical specification:
A. All materials with wastage & All labour
B. Handling, cutting, shifting, jointing, welding etc.
C. Rigid base of plywood / steel plaster with leak proof joints
D. Steel prop or system designed staging system. (Timber / Bamboo props staging not allowed)
E. Moulds of correct size, shape with flexibility to dismantle without kicks
F. Erection at all heights, leads, lifts and depths.
G. Erection to collect line, level, plumb and within tolerances as specified.
H. Leaving pockets, holes, conduits etc.
I. Shuttering oil
J. Maintaining in position till concrete attain desired strength.
K. Temporary openings in the forms for pouring concrete and removing rubbish.
L. Fixing inserts and openings at the correct line and level and any required stage to support the same at the directed height and place.
M. Platforms, if any, required to keep check on form while the concreting is in progress
N. Cleaning the shuttering.
2.10 Providing, fabricating, erecting and fixing in position 12mm thick waterproof ply centering and shuttering true to line and level, including required height's steel propping and staging, at all heights/levels, applying shuttering removal chemical emulsion/oil as approved, required bracing, if specified chamfering exposed edges, corners of beams, columns, walls etc., making leak proof joints etc. complete, at all leads and lift. Also include safely removing and dismantling the aforesaid assembly after specified or as approved period from the day of casting of concreting to the satisfaction of the Engineer in charge. The item shall also include the required staging and supporting arrangements. Sofit of slabs shall be fairface finished with no undulation of more than 2mm permitted. Any defect noticed shall be corrected by grinding or as approved by Engineer in charge, at Contractor's cost. The staging and formwork design shall be submitted to the Enginner in charge and got approval from Structural Consultant before proceeding to erect the same. (Up to floor to floor height of 3.5m)
a i) Retaining wall/ Columns / shear walls of all shapes and size. Sqm 61,153.00 0
b iii) Beams at all levels Sqm 12,563.00 0
c iv) Slabs / chajja slab at all level. Sqm 10,551.00 0
d v) Staircase including steps Sqm 2,607.00 0
2.10.1 -Do- as per item above but using steel sheet form work
h i) Footing / Raft / Pile caps Sqm 7,624.00 0
2.11 Extra for additional height in centering, shuttering where ever required with adequate bracing, propping etc., including cost of de-shuttering and decentering at all levels, over a height of 3.5 m, for every additional height of 1 metre or part thereof (Plan area to be measured).
2.11.1 a) Suspended floors, roofs, landing, beams and balconies (Plan area to be measured) Sqm 1,000.00 0
2.12 Providing and filling with styrofoam (minimum compressive strength 9.1 T/Sqm and density of 30 Kg/cum) lightweight filling to enable casting of Double slab build-up (refer drawing A14-01, detail-19) Cum 9.00 0
2.13 Providing and fixing roofing consist of galvanized steel deck sheet conforming to IS 277:1992 used as permanent shuttering over which reinforcement steel as per structural design and drawings shall be placed and tied complete, including all necessary cover blocks, binding wire and supports required for proper placement of reinforcement. The metal deck shall be supported on structural steel beams with shear studs complete. (Structural steel members such as beams, columns, joists etc., reinforcement steel and concrete of different grades as per design shall be measured and paid separately) Sqm 15,717.00 0
2.14 Providing, transporting, hoisting and fixing at all levels precast reinforced cement concrete of M40 grade in curved vertical panels of sizes and shapes as per Drawing No. A-17-1, 2 & 3 along with Structural drawing as listed below including the cost of required centering, shuttering, reinforcement including required designed lifting anchors of approved make Halfen or equivalent, including securing the panels with tounge & groove / butt jointed as per details at the locations, fixing with 317 grade Stainless steel designed chemical anchor, nuts & bolts etc. to the structural steel framing (structural steel paid separately), the panels are to be form finihsed from inside, etc. all complete to the entire satisfaction of the EIC. (Panel Type A-1 to A-8, B-1 to B-8, C-1 to C-4 & D-1 to D-4) (external elevation area x thickness of panel shall be measured for payment) Cum 739.00 0
2.15 Boring, providing and installation bored cast-in-situ reinforced cement concrete piles of garde M-25 of specified diameter and length below pile cap, to carry a safe working load not less than specified, excluding the cost of steel reinforcement but including the cost of boring with bentonite solution and temporary casing of appropriate length for setting out and removal of same and the length of the pile to be embedded in the pile cap etc. by Crawler mounted, telescopic boom hydraulic pilling Rig all complete, including removal of excavated earth with all its lifts and leads (length of pile for payment shall be measured up to bottom of pile cap).
2.15.1 600mm dia piles Rmt 33,114.00 0
TOTAL OF STRUCTURAL WORK 0
3. MASONRY WORK
All work as detailed in Technical specifications and drawings. The rate shall include the following, in addition to the “Measurement / Rate“ as mentioned in Technical specification:
A. All materials with wastage
C. Supply & Testing of Bricks / Blocks/ Rubbles
D. Making bonds
F. Forming arches
G. Work at heights, depths, lifts and leads
H. Racking out joints
J. Required scaffolding
K. Patli beam concrete
L. Steel binding, placing etc.
M. Leaving holes for fixing pipes etc
L. Building in ends of RC or steel members and making good
3.1 AAC BLOCK MASONRY Providing and laying Autoclaved Aerated concrete (AAC) blocks masonry 100 mm to 125 mm thick with Grade-I AAC blocks of density 551 to 650 kg/ cum conforming to IS: 2185 (Part 3) in super structure above plinth level up to floor V level in cement mortar 1:4 (1 cement : 4 coarse sand). The rate includes providing and placing in position 2 Nos 6 mm dia M.S. bars at every third course of masonry work. Cum 500.00 0
3.2 AAC BLOCK MASONRY Providing and laying Autoclaved Aerated concrete (AAC) blocks masonry with 150 mm to 500 mm thick with Grade-1 AAC blocks of density 551 to 650 kg/cum conforming to IS:2185 (Part 3) in super structure above plinth level up to floor V level with RCC band at sill level and lintel level with approved block laying polymer modified adhesive mortar all complete as per direction of Engineer-in-Charge. {The payment of RCC band and reinforcement shall be made for seperately).(Refer-A13/01 & Det-1/A13-08) Cum 2,432.00 0
Brick work with non modular fly ash bricks conforming to IS:12894,class designation 10 average compressive strength in super structure above plinth level up to floor V level in :
3.3 Cement mortar 1:4 (1 cement : 4 coarse sand) (Refer-A13-01 & Det-1/A13-08) Cum 1,842.00 0
TOTAL OF MASONRY WORK 0
4. WATERPROOFING WORK
Toilet Waterproofing
4.1 Providing and applying two component high performance highly flexible cementitious waterproofing coating having minimum elongation of 200% (as per ASTM D412: 2016), tensile strength >1.5 MPa (as per ASTM D412: 2016), adhesion strength > 1.2 MPa (as per ASTM D 7234:2019), water vapour transmission less than 22.6 g/m2/day (as per ASTM E96: 2022), crack bridging more than 2mm (as per EN 1062-7:2004), water permeability of 5 bar positive pressure (as per EN 12390-8:2019). The concrete surface must be brought into surface saturated dry condition (SSD). The coating shall be applied with a total consumption of 2.2 Kg/Sqm in two coats using a roller/brush on the prepared concrete substrate) sunken slab / flat slab and on walls up to 1m height. All the coats to be applied in perpendicular direction to each other and allow the coating to air cure for 3-5 days before conducting water ponding test for 24 Hrs. The system includes base preparation of cleaning and preparation of surface with the help of wire brush or grinder, brushing and removal of flacky materials, grouting the porous area with cementitious grout, sealing the minor cracks, proper coving of minimum 25mm x 25mm using polymer modified mortar between slab and wall junctions followed by the application of waterproofing coating as per manufacturers specification and methodology. (Location : Toilets) Mode of measurement will be actual area treated. Sqm 1,986.00 0
Rate shall including required testing as mentioned below 1. Testing on mother slab, grouting - TEST 1 2. After completion of coating - TEST 2 3. Water for testing to be arranged by Contractor
Contractor to provide guarantee for 10 years Rs.500/- stamp paper in approved proforma. Water for testing shall be in part of Contractor's scope.
4.2 Providing and filling light weight AAC bats (of size 40-60 mm) with cement mortar mixed in the ratio 1:3:6 (1 cement : 3 coarse sand : 6 block bats) including mixing of approved water proofing compound in recommended proportion. The laid brick bat mix shall be well rammed and compacted as required. Further surfaces shall be screeded with cement concrete mix 1:1.5:3 (1 cement : 1.5 coarse sand : 3 stone grit of size 6 mm and below by volume) admixed with approved integral water proofing compound in recommended proportion, laid to an average thickness of 25mm and finished smooth or ready to receive finish material as specified. Care shall be taken prior to filling all pipes passing through sunk portion such that the pipes are pressure tested by maintaining pressure for 24 hours and junctions of pipes passing through walls, slabs are well grouted and sealed. Cum 1,472.00 0
This shall be tested by ponding water for required depth and maintaining for 72 hours. (Rate includes cost of AAC bats, cement mortar, top screed, labour charges for working at all levels, leads and heights). For payment the area of sunken slab and the depth of filling including the thickness of screed shall be measured.
4.3 Water Tank waterproofing Sqm 2,842.00 0
Providing and applying two component solvent free elastomeric polyurethane resin base coating for waterproofing and protection of water tanks. The concrete surface on which the coating is being applied should be minimum 28 days old and having residual moisture content <5 %, surface should be free from loose dust, dirt, loose mortar, curing compound and achieve surface profile of CSP4 or CSP5 level. Apply two component solvent free flexible polyurethane primer on the prepared surface using roller/brush in one coat @ 100gms/m2 and let it cure of 4-12hours followed by application of 2 coats of polyurethane coating after mixing the two components. It shall be applied in two coats by roller only with a total consumption of 1.4 kg/sq.m (0.5 kg/sq.m. in 1st coat and remaining in 2nd coat). Second coat to be applied in direction perpendicular to the first coat. Let the coating cure for 3-5 days for full cure before conducting water ponding test for 24 Hrs. Gap between the two coats application shall not exceed 12 hours.
The coating shall have specific gravity of 1.2 and solids content of 100%, elongation of 100% ±10% (as per ASTM D412), tensile Strength >10Mpa (as per ASTM D412), shore A Hardness >80 (as per ASTM D 2240), positive hydrostatic pressure resistance of 5bar (as per EN12390), negative hydrostatic pressure resistance of 5 bar (as per ASTM D7088), adhesion to concrete >2Mpa (as per ASTM D7234), water absorption <0.15 % (as per ASTM D570) and certified by CFTRI as per 21 CFR 175 – 300 of US – FDA for potable water contact all as per manufacturers' specification, etc. complete.
Wall and Floor Junction Treatment: Making “V” grooves cut along the wall & slab joints for 10 x 10 mm using a hand cutter followed by cleaning the groove thoroughly and applying one coat of two component solvent free flexible polyurethane primer and filling the gap with polyurethane/hybrid polyurethane sealant in the groove. After curing of sealant, apply one coat of primer in a width of 120mm, let it cure and fix the specially coated 3-ply elastic corner Joint tape using polyurethane coating.
All tie rod shall be chipped for a depth of 50mm on both the sides of opening of wall, then completely remove the dust from the holes by blower and then fill the tie rod holes with approved non-shrink cementitious grout for full depth of hole and allow to dry for minimun 3 days. During filling of tie rod leave a gap of 10mm from the surface and the same should be filled with polyurethane/hybrid polyurethane sealant.
Treatment around pipe Core Cut Areas : All the pipes to placed / inserted in the core cut areas, shall be placed appropriately to be grouted around the cut bores.Roughening the pipe surface with hacksaw blade and applying a coat of SBR modified latex and sprinkling sand for proper adhesion. Grouting the gaps between the pipe and the core cutting by high strength non-shrink cementitious grout or micro-concrete that shall be poured into the gaps after fixing in place an effective leak-free shuttering and support. Allow the grout to set for 24 hrs. And do the moist curing for 5 days. The area around the pipes (10mm) shall be filled with polyurethane/hybrid polyurethane sealant followed by flashing treatment with polyurethane waterproofing coating and specially coated 3-ply elastomeric corner joint tape embeded between the two coats of waterproofing membrane.
All systems to be installed as per manufacturer's recommendations, etc. complete with all lead and lift for all materials and labour and as directed by PM and giving guarantee for 10 years on Rs. 500/- Stamp paper in approved proforma.
4.4 Internal surface of lift pit Sqm 474.00 0
Providing and applying in depth penetrating type crystalline slurry waterproofing system (Mix Ratio of Water : powder = 0.4), to be applied as a slurry application in 2 coats at a total consumption of approx. 1.6 Kg / sqm as per manufacturer's recommendation applied on the internal wall & floor surface of the Liftpit, to be done post construction, including cleaning of the surface as per manufacturers specification, treating the construction joints with crystalline plugging mortar, treating the honeycombs, & cracks with cementitious injections admixing expansive additive @ 225 gms per bag of cement, etc. complete. The crystalline slurry coating shall have following minimum properties: 1. Water head resistance > 70m as per DIN 1048, 2. Bulk Density > 1150 kg/m3, 3. Crack sealing capacity upto 0.5mm
All systems to be installed as per manufacturer's recommendations, etc. complete with all lead and lift for all materials and labour and as directed by PM and giving guarantee for 10 years on Rs. 500/- Stamp paper in approved proforma.
4.5 Waterproofing on raft slab Sqm 19,249.00 0
Designing, providing, installing Membrane waterproofing system below RCC foundation / raft. System should create 100% water tight and chemical barrier around the structure. All complete to approval of PM and system shall be guaranteed for 10 years on approved stamp paper. System recommended and specified are as under.
Supplying and laying composite minimum 1.2mm thick, pre-applied, Fully bonded, pure HDPE membrane, over P.C.C. The HDPE membrane shall be fully bonded to the Raft bottom and shall consist of 3 layers - highly resilient HDPE film of minimum 0.9mm Thick, pressure sensitive adhesive and a granular protective layer. The membrane shall have minimum of 75mm side and end laps which shall be sealed with double sided tape. The membrane shall be loosely laid onto the PCC surface and shall be capable of receiving the structural steel & concrete directly over the membrane. The membrane shall be laid as per the manufacturer's specification and shall be turned up on the vertical surfaces upto 50mm depth from the top of the raft / foundation within the shutter of the raft / foundation sides to ensure no joint/overlap in the membrane at the corner, this shall include cleaning & removal of all the dust, dirt, oil, grease, cement laitance, loose particle & prepare the P.C.C. Substrate for laying of HDPE membrane, all as per manufacturer's instructions, etc, complete.
The membrane shall have minimum following properties: 1. Tensile Strength > 25 MPa as per ASTM D 412, 2. Elongation at Break > 500 % as per ASTM D 412, 3. Peel Adhesion to Concrete > 1500 N/m as per ASTM D903, 4. Puncture Resistance > 1000 N as per ASTM E 154, 5. Resistance to Hydrostatic Head > 70m as per ASTM D 5385, 6. Low Temperature Flexibility < (-)25 degC as per ASTM D1970, 7. Lap Peel Adhesion > 1500 N/m as per ASTM D1876, 8. Lateral Water Migration Resistance > 70m as per ASTM D5385.
All systems to be installed as per manufacturer's recommendations, etc. complete with all lead and lift for all materials and labour and as directed by PM and giving guarantee for 10 years on appropriate Stamp paper in approved proforma.
4.6 Waterproofing outside RCC walls - Vertical Sqm 5,472.00 0
Providing and laying 1.5 mm thick cross laminated SBS self adhesive waterproofing membrane based on based on a tropical grade of polymer modified bitumen laminated onto an impervious, non-perforated, cross laminated HDPE film. The compound membrane should exhibit tensile strength (L/T) > 3.5 N/mm2 (as per ASTM D 412-06), elongation (Longitudinal) > 300% & elongation (transverse) > 200% (as per ASTM D 412-06), puncture resistance > 280 N (as per ASTM E154), resistance to hydrostatic pressure head > 60m (as per DIN 1048), peel adhesion > 1.5 N/mm (as per ASTM D 1000). The system includes base preparation of cleaning, brushing and removal of flacky materials, construction joint treatment, proper coving between slab and wall junctions and priming the surface with cold applied bituminous primer followed by application of SBS membrane. The SBS membrane should be sealed properly at joints & maintaining 75 mm overlap between the membrane selvedge & 100 mm overlap on the end joints of the membrane over the surface etc as per manufacturers specification and methodology.
Termination: The SBS membrane should be terminated at top using aluminium strip flashing with fasteners and the joint should be sealed with polyurethane/hybrid polyurethane Sealant Construction Joint Trearment: All construction Joints in the retaining wall shall be opened in V-groove size to maximum depth of 15mm, clean the exposed area with air blowing machine and seal the joints with polymer modified mortar using Cement : Sand = 1 : 4 and SBR latex @ 2 kg per Bag of cement and level with the surface.
Protection to the waterproofing system against backfilling: Providing & Fixing of 8-10 mm thick dimple protection board, over the waterproofing membrane for vertical surface stuck to the membrane by spot bonding method, using synthetic adhesive with butt joints to protect the coating from damages from back-filling materials.
All systems to be installed as per manufacturer's recommendations, etc. complete with all lead and lift for all materials and labour and as directed by PM and giving guarantee for 10 years on Rs. 500/- Stamp paper in approved proforma.
4.7 Terrace Waterproofing with Insulation Sqm 8,761.00 0
Providing and applying spray applied, 2-component instant setting liquid hybrid polyurea based elastomeric waterproofing membrane by high-pressure spray application with heated two component spray proportioning equipment. The proportioning equipment must be capable of supplying correct pressure and heat for the appropriate hose length on a consistent basis. The hybrid polyurea coating system must meet the requirements of ASTM C836, having zero VOC, solids by volume 100% (as per ASTM D2369), tensile strength >12 MPa (as per ASTM D412), elongation > 450% 9as per ASTM D412 ), tear strength shall be minimum 50 KN/m 9as per ASTM D624), adhesion on concrete > 1.5 MPa (as per ASTM D 4541), shore A hardness not less than 85 (as per ASTM D2240), dynamic crack bridging ability with no crack observed in the coating after 20000 sinusoidal cycles (as per as per EN 1062-7 Method B- B3.2 of class B 3.2), abrasion resistance of not more than 60mg loss (1 Kg,CS 10 Wheels,1000 cycles - as per ASTM D4060), impact resistance > 10 N.m (as per ASTM D2794), resistance to hydrostatic pressure head of 7 Bar (as per ASTM D 5385), crack bridging ability of minimum 3.2mm (as per ASTM C1305), resistance to root (as per CEN TS/14416) and resistance to fire to as per EN 13501-1 Class B.
The coating shall be applied with a total consumption of 1.65 Kg/Sqm to achieve a total system DFT of 1.5mm, thereby satisfy the requirements of LAM as per ASTM C898 and shall be applied on the entire horizontal surface extending upto 300mm height on the vertical surface as per the manufacturers specification and methodology. Water pond testing shall be carried after membrane coating and shall be treated with approved epoxy grout treatment if any leakages found.
The system includes base preparation of cleaning, brushing and removal of flaky materials, thorough grinding, construction joint treatment, making angle fillets of 50mm x 50mm with polymer modified mortar at all the junctions followed by priming the surface with two component solvent free epoxy primer which is applied with a consumption of 200 grams per Sqm, followed by spray application of hybrid polyurea waterproofing coating.
Thermal Insulation PUF Layer over Waterproofing system: Spray applying 50mm thick CFC & HCFC free spray applied polyurethane foam satisfying the requirements of application as per IS 12423-Part3 which is applied in multiple passes with each spray pass of average 10-12mm thick. The spray applied polyurethane foam must have a free rise density of 33-35 kg/m³ and a spray density in the range of 45- 50 kg/m³(as per ASTM D1622), initial thermal conductivity of 0.023 W/m.k at 24°C (as per ASTM C518), tensile strength of >400kPa (as per ASTM D 1623), compressive strength greater than 300kPa (as per ASTM D-1621), closed cell content greater than 95% (as per IS 11239 Part5 ) , water absorption less than 1.5% (asper ASTM D2856), fire test property conforming to Class B2 as per DIN 4102 and Dimensional Stability of < 1.5% for 7 days when tested at -15& +70°C (as per ASTM D2126).
Supplying & laying 120 gsm Geotextile (non woven polyester) over the entire membrane maintaining proper overlaps.
Horizontal Protection & Slope Making Layer: Providing & laying of protective screed of M20 grade by keeping minimum 50mm thickness at drainage point with slope 1:100 containing 12 mm, 100% virgin polypropylene fibers @ 0.9 Kg/Cu.m with a broom finish, well compacted, curing for 7 days etc. complete. The screed shall be raised to the wall in the form of vatta to achieve a smooth corner. The screed shall be divided into panels of 2 mtr X 2 mtr with 6 mm wide x 10 mm deep construction joint and filling the same with polyurethane/polysulphide/hybrid sealant.
Vertical protection: Apply 1 coat of spatter dash bond coat mixed in the ratio of 1 part SBR latex: Cement and 2 parts of clean fine coarse sand and 1 part water to make thick slurry coat over the waterproof coating on the vertical walls upto 300mm height. Apply 12mm thick plaster over the prepared surface of cement sand mortar admixed with integral waterproofing compound conforming to IS 2645:2003 @ 220ml per bag of cement. Including finishing & water curing of plaster for minimum 7 days.
Treatment around pipe Core Cut Areas : All the pipes to placed / inserted in the core cut areas, shall be placed appropriately to be grouted around the cut bores. Roughening the pipe surface with hacksaw blade and applying a coat of SBR modified latex and sprinkling sand for proper adhesion. Grouting the gaps between the pipe and the core cutting by high strength non-shrink cementitious grout or micro-Concrete that shall be poured into the gaps after fixing in place an effective leak-free shuttering and support. Allow the grout to set for 24 hrs. and do the moist curing for 5 days. The area around the pipes (10mm) shall be filled with polyurethane/hybrid polyurethane sealant followed by flashing treatment with polyurethane waterproofing coating and specially coated 3-ply elastic corner Joint tape embedded between the two coats of waterproofing membrane.
All systems to be installed as per manufacturer's recommendations, etc. complete with all lead and lift for all materials and labour and as directed by PM and giving guarantee for 10 years on Rs. 100/- Stamp paper in approved proforma.
4.7 Waterproofing with 2K cementitious coating for Waterbodies, consisting of followings: Sqm 476.00 0
Bore Packing: For Over Flow Pipes Preparing the inside surface of core and PVC/ MS Pipe by roughening using suitable Sand paper to get better adhesion prior to packing works. Cleaning the surface by wire brushing followed water jet to remove any laitance or loose flaky particles. Providing necessary formwork for packing the bore using suitable arrangement (depending upon site conditions).Applying a coat of styrene-butadiene based polymer coating using Nitobond SBR to enhance adhesion between the packing material and other surfaces. Packing the gap using non shrink cement polymer based grout using Conbextra GP2 upto the surface of the bore whilst the Nitobobd SBR is in tacky state.
Injection Grouting Providing Chemical injection treatment in the form of pressure grouting to the leakage points, cold joint by injecting cement slurry mixed with grout admixture Cebex 100 @ 225 gms per bag of cement, in the required consistency through the prefixed PVC/ Aluminium/ GI nozzles in the 18mm dia holes, fixing of nozzles with Renderoc Plug and final cutting the projected nozzles and sealing off the nozzles after the injection operation is over with Renderoc plug etc. as per manufacturers specification and as directed.
Coving/ Vatta Providing and application of 50-75mm vatta at the junction of slab and vertical walls with cement mortar (1:4) and admixed with SBR latex at dosage of 2.5 Ltr per 50kg cement and finishing the same as per EIC.
Waterproofing Coating Providing and carry out waterproofing treatment to Waterbodies etc.after proper surface preparation to remove loose dust,dirt etc.pre-dampening concrete surface, mixing and application of two coats of cementitious coating @ 2.5kg/ sqm at 1.5mm thickness using suitable brush or roller as per coverage etc. complete including all tools and tackles as per manufacturer’s specification.Cured material shall comply with ASTMD4060, ASTMD4541, ASTMD638, ASTMC836 and possess below properties: Mixed density: 1.68g/cc, Elongation >150%, Adhesion to concrete ->1N/mm2, Non-toxic,Static crack accommodation-1 mm
Providing and laying protective screed of average 50mm thickness admixed with Integral Waterproofing liquid admixture ata dosage of 150 ml per 50 kg cement.
Providing and applying plaster of average 15-20mm thickness admixed with Integral Waterproofing liquid admixture at a dosage of 150 ml per 50 kg cement.
TOTAL OF WATERPROOFING WORK 0
5. FLOORING WORK
The rates quoted by the Contractor for items under this head shall be inclusive of the following :
a) All flooring to be protected by approved suitable floor protection system of closed cell, polymer based micro cellular foam, reinforced with high performance polymers sheet during construction. Flooring to be covered over in finished condition and after uncovering to be delivered in a finished condition free of scratches, lines and any other deformities etc.
b) All the flooring, dado & cladding shall be fixed using approved quality cement based high polymermodified quick-set tile adhesive (Water based) conforming to IS: 15477, in average 3mm thickness or more as required.
c) The contractor shall procure mortar, adhesive, grout etc. of approved quality design and standard and he will not change source of supply without written permission from PM and with revised samples being approved.
d) Contractor shall prepare and install mockups for floor and wall as per drawings. Mockups may be part of completed work if undistributed. Nothing extra shall be paid on this account.
e) Joint patterns to be followed. No extra cuts for variable joint patterns, shall be paid for wastage.
f) Skirtings to have profiled edges as per PM's instructions. No extra cost to be paid for plaster chipping, required to adjust skirtings levels. However, cost of mouldings to be indicated separately, so as to deduct cost towards the same, incase profiling is avoided.
g) All necessary cut outs in walls, clearing up plaster towards work required for services, not to be paid for separately, even if it is conducted subsequent to work completion. No extra for cutting, edge finishing required for junction boxes of electrical works, etc.
h) Bedding shall be done in grey cement & white cement slurry to be used for laying marble.
i) Stone to be coated with invisible, penetrating sealer which forms an invisible water repellent coating (Laticrete 190 sealer or equivalent approved) on all (Six) sides as per manufacturer recommendations
j) All the stone cladding shall be protected by using clear coat of nano technology based impregnating sealer (Maxi Seal of Laticrete or equivalent approved) designed for the protection of all medium to dense porous tile/stone and grout surfaces. The rate of items shall include the same and no extra shall be paid towards the same.
k) Grouts in flooring i) All interior flooring to have 3 mm wide Cement Sanded grout- L-500 (Laticrete). ii) All interior and exterior Cladding to have 5 mm wide sanded Grout- L 500 (Laticrete) iii) All toilet wall dados to have 3 mm wide Laticrete epoxy grout SP-100 (Laticrete) iv) All exterior flooring to have L 500 -5 mm wide sanded grout (Laticrete)
l) The quoted rate shall include the cost of all materials and labour involved in all the operations as specified above and to execute the work as per approved drawings including staging / scaffolding etc. necessary for execution of the respective item for all height and for all floor levels. Item measurable in sqm.
Drawing no- A12-04 Det -1/A14-01
5.1 Providing and fixing 20 mm thick gang saw cut, mirror polished, Premoulded and prepolished, machine cut for kitchen platforms, vanity counters, coping, tread, landscaping, window sills, facias, parapet top and similar locations of required size, approved shade, colour and texture laid over using approved adhesive over cement concrete screed (paid separately), joints grouted with approved matching colour grout epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels, as per sample approved by Engineer in-charge. Necessary MS/ SS frame structure for fixing the stone counter shall be paid in relevant tender item.
Honed Granite of any colour and shade
Area of slab over 0.50 sqm
5.1.1 a) Honed Granite stone slab (Basic Rate: Rs. 200/- per Sqft without GST) Sqm 289.00 0
5.2 Extra for fixing marble/ granite stone over and above corresponding in facia and drops of width upto 200mm with epoxy resin based adhesive including cleaning etc complete. Facia shall be match with shade of counter or platform. Rmt 91.00 0
5.3 Extra for providing opening of required size & shape for wash basins/ kitchen sink in kitchen platform, vanity counters and similar location in marble/ Granite/ stone work including necessary holes for pillar taps etc. including rubbing and polishing of cut edges etc. complete. Nos 82.00 0
5.4 Providing and fixing stone slab with table rubbed, edges rounded and both side polished, of size 450 x 900 mm deep and 40 mm thick, fixed in urinal partitions by cutting a chase of appropriate width with chase cutter and embedding the stone in the chase with epoxy grout or with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 6 mm nominal size) as per direction of Engineer-in-charge and finished smooth.
5.4.1 Granite Stone of approved shade (Basic Rate: Rs. 350/- per Sqft without GST) Refer A12-04 Det -1/A14-01 Sqm 14.00 0
5.5 Providing and fixing premoulded and prefinished, machine cut stone for coping, parapet top and similar locations of required size, approved shade, colour and texture laid using approved adhesive over cement concrete screed (paid separately), joints grouted with approved matching coulour grout, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels, as per sample approved by Engineer in-charge.
5.5.1 50 mm thick Sand stone of rough finish and colour and shade as per selection, (Basic rate of stone -Rs-400/- per Sqft without GST) Refer A12-08 Det - 1,2,3,4,6 Sqm 1,178.00 0
5.6 Providing and laying Stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 25 mm thick stone slab using approved adhesive over cement concrete screed (paid separately), joints grouted with approved matching colour grout, including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge.
5.6.1 Honed finish Steel grey Granite stone slab of 300mm x 300mm (Basic rate of stone -Rs-213/- per Sqft without GST) Refer A12-04 Det -1/A14-01 Sqm 763.00 0
5.6.2 Polished Grey Granite stone slab of 600mm x 600mm (Basic rate of stone -Rs-232/- per Sqft without GST) Refer A12-04 Det -1/A14-01 Sqm 234.00 0
5.6.3 Honed finish Mandana-1 stone slab of 900mm x 900mm (Basic rate of stone -Rs-448/- per Sqft without GST) Refer A12-04 Det -1/A14-01 Sqm 5,268.00 0
5.6.3 Honed finish Mandana-2 stone slab of 900mm x 900mm (Basic rate of stone -Rs-448/- per Sqft without GST) Refer A12-04 Det -1/A14-01 Sqm 540.00 0
5.7 Providing and laying Stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 35 mm thick stone slab using approved adhesive over cement concrete screed (paid separately), joints grouted with approved matching colour grout, including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge.
5.7.1 Honed finish Sand stone slab of 300mm x 300mm (Basic rate of stone -Rs-377/- per Sqft without GST) Refer A12-04 Det -1/A14-01 Sqm 67.00 0
5.8 Providing and laying polished Kota stone slab 600mm x 600mm flooring using approved adhesive over cement concrete screed (paid separately), joints grouted with approved matching coulour grout, including rubbing and polishing etc. complete. (A) 25mm thick Refer A12-04 Det -4/A14-01 Sqm 7,619.00 0
5.9 Providing and fixing 25mm thick approved up to 300mm wide Kota stone treads in 3 peices to full length of step and machine cut, machine polished. Treads to be rounded at front and all exposed edges machine polished. Further treads to have edge polished chamfering with 3 nos. (6mm x 3mm deep) grooves on top at front or as detailed in drawing for antiskid effect as shown in the drawing. Treads fix to be using approved adhesive over cement concrete screed (paid separately), joints grouted with approved matching coulour grout,, curing, cleaning, polishing etc. all complete at all heights and leads to the approval of the Engineer in charge. (Basic rate of stone -Rs-113/- per Sqft) Refer A12-04 Det -4/A14-01 Sqm 633.00 0
5.10 Providing and fixing 25mm thick and about 150mm high approved Kota stone risers, skirting machine cut and machine polished in 3 piece or as directed, to full length of step, stone fixed by approved adhesive on back, to correct line, level and plumb. Joints are well cleaned grouted with matching colour approved readymade grout, curing, polishing, cleaned and where specified or shown in drawing exposed edge of stone rounded / chamfered and polished, skirting to be match with wall cladding/ flooring pattern all complete to the satisfaction of the Engineer in charge. (Basic rate of stone -Rs-113/- per Sqft without GST) Refer A12-04 Det -4/A14-01 Sqm 360.00 0
5.11 Providing and fixing 25mm thick approved up to 300mm wide Mandana stone treads in 3 peices to full length of step and machine cut, machine polished. Treads to be rounded at front and all exposed edges machine polished. Further treads to have edge polished chamfering with 3 nos. (6mm x 3mm deep) grooves on top at front or as detailed in drawing for antiskid effect as shown in the drawing. Treads fix to be using approved adhesive over cement concrete screed (paid separately), joints grouted with approved matching coulour grout,, curing, cleaning, polishing etc. all complete at all heights and leads to the approval of the Engineer in charge. (Basic rate of stone -Rs-448/- per Sqft without GST) Refer A12-04 Det -1/A14-01 Sqm 60.00 0
5.11.1 -Do as per above item 5.11 but for 450mm wide Mandana stone treads as shown in drawing Refer A12-04 Det -1/A14-01 Sqm 32.00 0
5.12 Providing and fixing 25mm thick and about 150mm high approved Mandana stone risers, skirting machine cut and machine polished in 3 piece or as directed, to full length of step, stone fixed by approved adhesive on back, to correct line, level and plumb. Joints are well cleaned grouted with matching colour approved readymade grout, curing, polishing, cleaned and where specified or shown in drawing exposed edge of stone rounded / chamfered and polished, skirting to be match with wall cladding/ flooring pattern all complete to the satisfaction of the Engineer in charge. (Basic rate of stone -Rs-448/- per Sqft without GST) Refer A12-04 Det -1/A14-01 Sqm 32.00 0
5.13 P & L 12" x 12" vitrified 10 mm thick tile flooring on new surface or fixing on existing flooring by using approved adhesive over cement concrete screed (paid separately), joints grouted with approved matching coulour grout, including dismentaling of existing flooring and jointed with color cement slurry including finised with flush pointing & cleaning the surface etc. complete for antiskit (Basic rate of tile-Rs-150/- per Sqft without GST) Refer A12-04 Det -7/A14-01 Sqm 174.00 0
5.14 Providing, fabricating and laying recessed electro-forged SS304 walk-off grating mat brushed finish made out of stainless steel 304 angle frame and hardware (Balco or equivalent), ADA compliant, slip resistant, custom size as shown in plans fixed on cement concrete bed (concrete bed measured & paid sepretley) with recess to lay mat of overall 100mm thick floor. All the work to be protected till handing over the project & to the approval of EIC. Refer-A12-04 & 8/A14-01 Sqm 77.00 0
5.14.1 -Do as above item no-5.14 but for G.I walk off bar grating mat Refer- DET 8A / A14-01, A12-04 Sqm 38.00 0
5.15 Providing and laying 9mm thick approved make tufted multi-level loop pile scroll Carpet tile flooring (500mm x 500mm) as per detailed and instruction of approved manufacturer etc. Carpet flooring shall be fixed over exisiting marble mosaic flooring with as adhesive as recommended by the approved of carpet manufacturer. Required edging angles, junction, entrances etc. shall be fixed and finished with as per recommendation of the carpet manufacturer to approval of the Engineer in charge / Architect. Sub-base floor to be leveled, cleaned all complete at all heights and leads to the entire satisfaction of the Engineer in charge. (Basic rate of tile-Rs-220/- per Sqft without GST) Refer A12-04 & Det -10/A14-01 Sqm 682.00 0
5.16 Providing and laying C.C. pavement of mix M-30 with ready mixed concrete from batching plant. The ready mixed concrete shall be laid and finished with screed board vibrator, vaccum dewatering process and finally finished by floating, brooming with wire brush etc. complete as per specifications and directions of Engineer-in-charge. Refer A12-04 & 2/A14-01 Cum 628.00 0
5.17 Providing and laying C.C. pavement of mix M-25 with ready mixed concrete from batching plant. The ready mixed concrete shall be laid and finished with screed board vibrator , vaccum dewatering process and finally finished by floating, brooming with wire brush etc. complete as per specifications and directions of Engineer-in-charge. (Note:- Cement content considered in this item is @ 330 kg/cum. Excess/less cement used as per design mix is payable/ recoverable separately).Refer A12-04 & 13/A14-01 Cum 39.00 0
5.18 Providing and fixing of 100mm high 25mm thick 1st quality Teak Wood skirting with SS screws, adhesive etc. all complete Refer -A12-06 & 3/A14-03 Rmt 420.00 0
5.19 Providing and installing 20mm thick approved 1st quality Teak wood plank flooring of approved make with tongue and groove joint system as shown in drawings and instruction of approved manufacturer / PM of approved shade; fixed over 12mm thick approved marine ply surface fixed over existing IPS. Ply shall be chemically treated, seasoned and anti-termite treated including cleaning, treating base concrete screed, treating ply with a thin coat of polyurethane prior to being screwed down to concrete floors prior to fixing and making groove/joint around edges as specified in drawing and by the manufacturer etc. all as detailed in technical specification, drawings and that of approved flooring manufacturer etc. to entire satisfaction of the PM. (Refer drawings No.A12-04 & 05/A14-01) Sqm 785.00 0
5.20 Providing and fixing Wooden deck (25 mm wooden planking, tongued and grooved 2nd quality teak wood planking / flooring including PU polish on GI frame and supports as shown in the drawing. Rate shall include preparing and submitting shop drawings with all fixing details prior to fabrication and execution etc. all complete as shown in the drawing and directed by Engineer in chrage. ('GI frame and support as shown in the drawing to be paid for seperatly) Drg Refer -A12-04 & 12/A14-01 Sqm 127.00 0
5.21 Providing and fabricating GI frame work for above item as per variable height with concrete pedestal as per drawings No.A14-01-Detail-12 (Note: Concrete to be paid for seperatly) Kg 5,715.00 0
5.22 Providing and laying 10mm thick Vitrified tiles in different sizes (thickness to be specified by the manufacturer), with water absorption less than 0.08% and conforming to IS: 15622, of approved brand & manufacturer, in all colours and shade, in skirting, riser of steps, laid with cement based high polymer modified quick set tile adhesive (water based) conforming to IS: 154 77, including grouting of joints. Drg Refer -Det-07/A14-01
5.22.1 Size of Tile 600x600 mm including epoxy grouting of joints Sqm 4,514.00 0
5.23 Providing and laying polished kota stone slab 25mm thick in risers of steps,skirting Dedo and pillars laid on 10mm thick cement mortar 1:3 (1-Cement : 3 coarse sand) and jointed with gray cement slury mixed with pigment to match the shade of slab including rubbing and polishing etc. complete. Drg Refer -Det-14 & A7-22 Sqm 516.00 0
5.24 Supply and installation of Rubber Tile Flooring, skirting having thickness of 5mm. This product is installed on floor base with adhesive. Sqm 26.00 0
Rubber tile of 5mm is made up of 85% black rubber granules and 15% synthetic EPDM granules. Rich colors, Environmental friendly, non-toxic, Recycled, non-pollution, Moderate and adjusted hardness, Excellent resilience, wear well, soft, anti-slip, anti-fatigue, Density (kg/m3):1000/1200, Hardness (Shore a):68, Stretch (MPA):2.2, Abrasion resistance:0.0075g (ASTM-D4060-01), Rebound resistance:55%, Friction coefficient: trends μs:0.995 trends μk:0.930, Shape deformation:42%, Thickness: 5mm ±0.3mm. etc. all complete as per detail drawing or as per instruction of Engineer in charge. Refer CODE-A12-04 & 3/A14-01
5.25 Providing and installing all weather 35mm thick Stone Deck Tile 600mm x 600mm size flooring with ABS plastic mesh and interlocking system, tiles made from travertine stone anti-skid rough finish fixed over waterproofing finished with leveled IPS, all complete to the entire satisfaction of the EIC. Refer A12-04 & 14/A14-01 Sqm 27.00 0
5.26 Providing and fixing dry cladding with 35mm thick gang saw cut stone with machine cut edges of uniform colour and size as per drawing, fixed to structural steel frame work and/ or with the help of cramps, pins etc. and sealing the joints with approved weather sealant as per Architectural drawing and direction of Engineer-in-charge. Item to include Providing and fixing adjustable stainless steel (grade 316) cramps of approved quality, required shape and size, adjustable with stainless steel nuts, bolts and washer (total weight not less than 260 gms), for dry stone cladding fixed on frame work at suitable location, including making necessary recesses in stone slab, drilling required holes etc complete as per direction of the Engineer-in-charge.
5.26.1 Sand stone - 35mm thick gang saw cut stone with 5mm wide joint filled approved PU grout (Basic rate of stone -Rs-377/- per Sqft without GST) - 125mm away from the internal wall Refer A12-05 & 6/A14-02 Sqm 4,853.00 0
5.26.2 35mm thick satin finish Mandana stone cladding filled approved PU grout (Basic rate of stone -Rs-392/- per Sqft without GST) - 125mm away from the internal wall Refer A12-05 & 6/A14-02 Sqm 2,254.00 0
5.26.3 35mm thick mirror finish Granite stone cladding filled approved PU grout (Basic rate of stone (Basic rate of stone -Rs-419/- per Sqft without GST) - 125mm away from the internal wall Refer A12-05 & 6/A14-02 Sqm 1,002.00 0
5.26.4 -Do- as above 5.26 but 35mm thick last stone at lintel filled approved PU grout (Basic rate of stone (Location : Interior) (Basic rate of stone -Rs-338/- per Sqft without GST) Drawing no- A11-04- Detail-3 & 4 Sqm 313.00 0
5.26.5 -Do- as above 5.26.1.1 but 250mm away from the external wall Refer A11-01 Det - 02 Sqm 70.00 0
5.29 Providing and fixing machine cut, composite patterned wall wet cladding out of 25mm thick flamed finish Granite stone machine cut, machine polished to walls and columns. Stone fixed with required stainless steel pins / dowels / cramps including drilling holes, making notches etc. for securedly fixing with pins / cramps to wall. Stone fixed in position with approved readymix ploymer based adhesive in line and level and in pattern as shown in the drawing. Joints cleaned, grouted with approved ready made ploymer modified PU grout or cured and cleaned, further to include required double legged independent scaffolding etc. complete to the satisfaction of the EIC. (Basic Rate of stone: Rs. 315/- per Sqft without GST) Refer DWG. A14-02 DET 5 Sqm 13.00 0
5.30 Providing and laying cement concrete flooring 1:2:4 (1-cement : 2-coarse sand : 4-graded stone aggregate 20mm nominal size) laid in one layer and finished with a floating coat of neat cement. (The Contractor will provide for preparation or surface by cleaning, hacking and exposing aggregate to achieve the best bond, and any curling, lifting or debonding noticed shall be rectified by the contractor at his cost), protection, etc. complete to the entire satisfaction of the EIC. Cum 1,640.71 0
5.31 Providing and laying self leveling mortar using very low emission, polymer modified cementitious floor levelling compound which provides a smooth finish on subfloors before the application of resilient flooring. Sqm 946.00 0
5.32 RAISED ACCESS FLOOR SYSTEM
Providing and fixing removable raised/ false access flooring with system and its components of approved make for different plenum height with possible height adjustment upto 50mm, comprising of modular load bearing floor panels supported on G.I. rectangular stinger frame work and G.I. Pedestal etc. all complete, as per the architectural drawings, as specified and as directed by PM consisting of a) Providing at required spacing to form modular framework, pedestals made out of GI tube of thickness minimum 2 mm and 25 mm outer diameter, fully welded on to the G.I. Base plate of size 100mm x 100mm x 3mm at the bottom of the pedestal tube, G.I. pedestal head of size 75mmx75mmx3.5 mm welded with GI fully threaded stud 16mm outer diameter with two GI Check nuts screwed on the stud for level adjustment upto 50mm, locking and stabilizing the pedestal head in position at the required level. The pedestals shall be fixed to the subfloor (base) through base plate using epoxy based adhesive of approved make or the machine screw with rawl plug.
b) Stringers system in all steel construction hot dipped galvanized of rectangular size 570x20x30x0.80mm thick having holes at both ends for securing the stringers on to the pedestal head using fully threaded screws ensuring maximum lateral stability in all directions, the grid formed by the pedestal and stringer assembly shall receive the floor panel, this system shall provide adequate solid, rigid support for access floor panel, the system shall provide a minimum clear uninterrupted clearance between the bottom of the floor for electrical conduits and wiring etc. all complete as per the architectural drawings, as specified and as directed by the Engineer-in-charge. c) Providing and fixing Access Floor panel of 600x600x32 mm medium grade Filled Steel anti static high pressure Lamination of 800H grade (FS800H). Access Floor panel shall be steel welded construction with an enclosed bottom pan with uniform pattern of 64 hemispherical cones. The top and bottom plates of Steel Gauges: top 0.6 mm and bottom 0.7 mm fused spot welded together (minimum 64 welds in each dome and 20 welds along each flange).
5.33 i) About 300mm Finished Floor Height (FFH) with approved Vinyl flooring on tile flooring Refer A12-04 & 9/A14-01 Sqm 190.00 0
5.34 Providing and cladding with 1.2 mm thick Grade 304 grade Stainless Steel sheet, scratch resistant, in panel sizes as per approved design, confirming to relevant standards with all mechanical fixtures as per approved drawings and design, moulding of edges, buffing of surface, flushing of joints, silicon sealants, etc. all complete as per direction of Engineer In charge. MS Frame work & ply base shall be paid separately Refer A14-03 /Det-14 Sqm 69.00 0
5.35 Providing, fabricating and fixing circular column cladding using 1.2 mm thick Stainless Steel sheet of Grade 304, scratch-resistant finish, formed in curved panels (259mm) to required radius and panel sizes as per approved shop drawings. The work shall include bending, rolling, edge moulding, buffing/polishing to achieve uniform finish, and making flush joints with minimal visible gaps. The cladding shall be fixed over a prepared framework consisting of 50 x 25 mm GI sub-structure anchored to existing MS column (600Ø) using suitable fasteners, along with 6 mm thick flexi-ply (in multiple layers as required) to achieve the desired curvature. Stainless steel sheets shall be fixed using approved Z-clips, mechanical fasteners, and necessary supports ensuring proper alignment, rigidity, and true curvature.The item shall include provision of backing support, fixing accessories, stainless steel screws, spacers, silicon sealant at joints, finishing of edges, necessary cut-outs, and coordination with other services. All work shall be executed as per approved drawings, specifications, and instructions of the Engineer-in-Charge to achieve complete and seamless finish. Sqm 184.00 0
5.36 Providing and fixing 100 mm high Stainless steel sheet skirting made out of 1.2mm thick Stainless steel sheet SS304 moulded to profile inc sections fixed over 12mm thick marine ply using epoxy adhesives, fixing with screws, teakwood beading etc.),polishing etc , cutting, bending, curing etc all complete. (Drawing no- A12-06 & 4/A14-03 Rmt 12.00 0
5.37 Providing and laying loose gravel finish over terrace/roof surface, comprising supply of clean, hard, durable, and well-graded natural gravel of approved quality and size (20–40 mm or as specified), free from dust, dirt, and organic impurities.The work shall include thorough preparation of the surface, ensuring that the underlying waterproofing treatment/screed is complete, properly cured, and protected. Gravel shall be spread uniformly over the surface to a required thickness of 40–50 mm (or as directed), carefully leveled and dressed to achieve an even and consistent layer.The gravel layer shall be laid in a manner that ensures proper drainage, avoids displacement, and does not damage the underlying waterproofing system. The item shall include necessary edge retaining arrangements (if required), handling, loading/unloading, transportation, stacking, and all labour, tools, and tackles required for proper execution. All work shall be carried out strictly in accordance with approved drawings, technical specifications, and as directed by the Engineer-in-Charge, ensuring complete coverage and satisfactory performance. Sqm 5,280.00 0
TOTAL OF FLOORING WORK 0
a) All Plywood samples to be approved before procurement.
b) All exposed plywood to have approved wood lipping & stain to match.
c) All wood to be well seasoned.
d) All surfaces of wood to have antitermite treatment and anti-soligium paint, at multiple stages of the job. Agency appointed to be approved by PM.
e) All Plywood shall be Commercial plywood and to be as per specified List of Suppliers given.
f) All grooves of all thickness, inlay pattis in partitions and panellings to be included in quotations and no extra cost to be paid for the same.
g) Grooves to be provided at intersection of all separate surfaces such as wooden skirting and gypsum board. Cost of the same to be included in cost of skirting. Grooves also between carpentry items and civil items to be provided.
h) Paneling to be paid for only upto bottom of false ceiling. All necessary frame work required for anchoring partition above into slab above false ceiling to be included in cost of items.
i) Grooves to be provided at junction of partition, paneling 8mm to 10mm as required for carpet to slide in. No extra cost to be paid for the same.
j) All hardware to be in SS hairline/satin finish unless specified otherwise.
k) All extra frame work required within partitions and paneling for supporting of A.C.grills, fixing of skirting etc.and all such allied services.to be included in the cost of partitions.
l) Skirting in Plywood with finishing material on carpentry items to be included in the cost of carpentry items.
m) Wooden skirting over brick, concrete blocks or columns or partitions with gypsum board only to be paid for separately.
n) Drawings indicate only tentative locations and quantity of grooves, inlay pattis etc. Actual execution as per instructions of PM.
o) Bands upto 150mm thickness not to be paid for separately. Only in cases where width exceeding 150mm has to be fully put over existing paneling/partition/doors in order to create fully raised levels with complete grooves, wherever required.No extra cost shall be paid towards additional labour, hardware, adhesives etc. required to create the raised panel.
p) All wooden frames to form edgings wherever door openings occur. Cost of doors to include cost of frames wherever a part of carpentry items. Door frames to be paid for separately only wherever interface with civil work.
q) Additional bands in plywood, making niches, dub panels not to be charged for separately.
r) Nail free assembly of all types of fabric on paneling to be ensured.
s) No extra rate for height shall be paid
t) Rate. Quoted rate shall include the cost of all materials and labour involved in all the operations as specified above and to execute the work as per approved drawings including staging / scaffolding etc. necessary for execution of the respective item for all height and for all floor levels. Item measurable in sqm.
Rate shall be included :-
a) All materials with wastage, accessories, labour etc.
b) Approved wooden / Aluminium frame work.
c) Stainless steel fittings, fixtures, fasteners
d) Refer door schedule drawing no-A-13-15 & 16 for type of finishes on particular door.
6.1 Providing and fixing partition upto ceiling height consisting of G.I. frame and required board, including providing and fixing of frame work made of special section power pressed/ roll form G.I. sheet with zinc coating of 120 gms/sqm(both side inclusive), consisting of floor and ceiling channel 50mm wide having equal flanges of 32 mm and 0.50 mm thick, fixed to the floor and ceiling at the spacing of 610 mm centre to centre with dash fastener of 12.5 mm dia meter 50 mm length or suitable anchor fastener or metal screws with nylon plugs and the studs 48 mm wide having one flange of 34 mm and other flange 36 mm and 0.50 mm thick fixed vertically within flanges of floor and ceiling channel and placed at a spacing of 610 mm centre to centre by 6 mm dia bolts and nuts, including fixing of studs along both ends of partition fixed flush to wall with suitable anchor fastener or metal screws with nylon plugs at spacing of 450 mm centre to centre, and fixing of boards to both side of frame work by 25 mm long dry wall screws on studs, floor and ceiling channels at the spacing of 300 mm centre to centre.
The boards are to be fixed to the frame work with joints staggered to avoid through cracks, M.S. fixing channel of 99 mm width (0.9 mm thick having two flanges of 9.5 mm each) to be provided at the horizontal joints of two boards, fixed to the studs using metal to metal flat head screws, including jointing and finishing to a flush finish with recommended jointing compound, jointing tape, angle beads at corners (25 mm x 25 mm x 0.5 mm), joint finisher and two coats of primer suitable for board as per manufacture's specification and direction of engineer in charge all complete.
6.1.1 About 100mm overall thickness partition with 12mm thick marine grade Plywood conforming to IS 710 on both sides, further cladded with 12.5mm thick tapered edged plain Gypsum plaster board on both sides side as shown in the drawing. (Refer Drg No. Det-2/A13-08) Sqm 189.00 0
6.1.2 About 100mm overall thickness partition with 12mm thick marine grade Plywood conforming to IS 710 on both sides, further cladded with 12.5mm thick tapered edged plain Gypsum plaster board on both sides side & 50mm insulation as shown in the drawing. (Refer Drg No.A13-08-Detail-3) Sqm 51.00 0
6.1.3 About 400mm overall thickness partition with 19mm thick marine grade Plywood conforming to IS 710 on both sides, (fixed to MS structural column & beamframing-paid separetly) further cladded with 15mm thick oak wooden cladding on planks as approved both side as shown in the drawing. Reuired sub framing to be included in the cost. (Refer Drg No.A13-08-Detail-4) Sqm 452.00 0
6.1.4 Providing and fixing dry partition for elliptical ramp of about 300 mm overall thickness, consisting of 12 mm thick gypsum board and 18 mm thick marine grade plywood conforming to IS 710 fixed over MS sub-framing attached to structural columns and beams (structural steel work to be paid separately), including providing and fixing all necessary secondary framing members, cleats, screws, fasteners and accessories complete. The partition shall be suitable to receive stone cladding finish as per architectural drawings, including cutting, fitting, making openings, finishing and making good complete, all as per approved drawings, specifications and direction of Engineer-in-Charge. (Refer Drg. No. A13-08-Detail-5). Sqm 217.35 0
6.2 Overall 125mm wide Panelling with 12mm thick marine grade Plywood and 12.5mm thick approved Fire rated Gypsum board as shown in drawings with provision for light fixtures. Refer A12-05 REF : 17/A14-02 Sqm 8,267.00 0
6.3 Overall 125mm wide Panelling with 12mm thick marine grade Plywood and 15mm thick approved teak wood panel as shown in drawings with provision for light fixtures. Refer A12-05 REF : 7/A14-02 Sqm 1,545.00 0
6.4 Providing and fixing panelling with 8mm thick approved flexiply on existing column of 600mm dia. And finish with 6mm thick approved veneer as shown in drawing. REF: 15/A14-03 Sqm 48.00 0
6.5 Providing and fixing Roller blinds (UP-01) (75% black out, made out of 70% PVC, 30% Polyester) of approved make as per the manufacturer's specifications with drive unit, end plug, support brackets, roller tube, bottom rail, ball chains etc. Drive unit to be of moulded plastic with straight rectangular support pin and inserted into the tube end. It shall be driven by a ball chain pulley. End plug shall be moulded to plastic locking pin. The plug shall be inserted into the tube end. Support brackets shall be of zinc plated steel and provided with moulded plastic covers and used in right or left hand positions differentiated by acceptance of the rectangular drive unit support or the round idler plug pin. Roller tube shall be made out of roll formed steel of thick. Suitably protected against corrosion, and keyway integral with the tube to accommodate the spline. Bottom rail shall be a stiffening element inserted into a bottom rod pocket. Tube to be of the material as approved out of timber, PVC, steel or VB bottom rail. Ball chain shall be 2mm diameter cord with acetyl balls moulded co-axially to it on 6mm pitch to form ball chain. Refer A12-14 Sqm 681.00 0
6.6 Providing and fixing thermal insulation with Resin Bonded rock wool conforming to IS: 8183, having density 120 kg/m3,50 mm thick,wrapped in 200 G Virgin Polythene Bags fixed to wall with screw, rawel plug & washers and held and in position by criss cossing GI wire etc. complete as per directions of Engineer in- Charge. (for sound attenuation of mechanical spaces)
6.6.1 On Wall / Panelling Surface Refer-A12-05 REF : 11/A14-02 Sqm 4,556.00 0
6.6.1 On Ceiling Surface Refer-A12-07 & 8/A14-04 Sqm 2,249.00 0
6.7 Designing, providing and fixing wooden louvers as detailed in drawing (A14-05), including making shop drawings to show the fixing arrangment of louvers to back side slanted paneling using GI Z clips, GI framing in back paneling to take the load of the louvers and securing the same to back side wall / floor and adjusting the same as per site conditions, shop drawings including mock up to be approved by the Architect & PMC prior to execution. The item comprising of:
6.7 Providing and fixing partition / panelling upto ceiling height consisting of G.I. framework and approved quality plywood backing with finish paneling, including providing and fixing framework made out of G.I. framing system as required, securely anchored to floor, wall and ceiling with suitable dash fasteners, anchor fasteners, screws and plugs complete. The work shall include providing and fixing 19 mm thick plywood substrate fixed over the G.I. framework with suitable screws, and further providing and fixing 12 mm thick teak wood finished panel with clear polish/ clear finish as approved, fixed over plywood backing with approved adhesive/ screws complete. The item shall include necessary cutting, grooves, edge finishing, making openings for services, providing backing supports, alignment, levelling and all accessories required for complete installation. All joints shall be properly finished flush to surface, including necessary sanding, filling, polishing/ clear coating and finishing as per approved drawings and direction of Engineer-in-Charge, complete in all respects. (Refer-A14-05) Sqm 85.00 0
6.8 Providing and fixing wooden louvers approximately 250 mm wide x 60mm thick as per approved drawing and design, comprising 12 mm thick teak finish wooden panels fixed on both sides over stainless steel square tube framework made out of 35 x 35 x 3.2 mm SS sections, complete with internal supports, Further to fix solid teak wood edging with clear polish finish, necessary anchors, fasteners, welding, cutting, grinding, anti-termite treatment and fixing arrangement. The work shall include fabrication of SS framework, provision for alignment, edge finishing, joint treatment, all hardware and accessories, complete in all respects as directed by the Architect/Engineer-in-charge. Measurements shall be taken in running metres of finished surface area. (Refer-A14-05) Rmt 329.00 0
6.9 Providing and fixing Wooden door with approved 1st quality teak wood door frame of size 45mm x 150mm size, fixed with holdfasts / dash fasteners / SS screws, frame to be finished with PU polish in approved shade to the exposed faces, the frame face in contact with masonry shall be applied with black japan paint. The shutter shall be factory made 45mm thick flush shutter of approved make confirming to IS 2202 (Part - I); Shutter shall be manufactured with exterior quality synthetic adhesive forming marine ply surfaces, internally lipped. Further shutter shall be finished with 4mm thick veneer finish including PU polish on both side of approved make, shade and design, hot pressed at factory, edges of shutter shall be provided with 6mm thick teakwood beadings using exterior quality synthetic adhesive, headless GI nails, screws, beading finished with PU polish, etc. Also including creating pattern / design of paneled shutter as shown in the drawing. Further providing and fixing ironmongeries as per schedule and drawings all complete to entire satisfaction of the PM. (Refer Door Schedule: A13-15,16)
6.9.1 Door D-B-G-01 (First Aid) overall size 900mm x 2400mm. with approved 4mm thick veneer finished. Nos 1.00 0
a) 5 Knl, Ball bearing offset hinges size 100 x 75 x 3mm, SSS - 3 Nos.
b) Cylindrical lock with knobs and key opening
c) Concealed door closer, Medium duty EN 2-4 with std arm, Silver finish - 1 No. (on bigger leaf)
d) Door stopper
e) Lever Handle
6.10 Providing and fixing Wooden door with approved 1st quality teak wood door frame of size 75mm x 250mm size, fixed with holdfasts / dash fasteners / SS screws, frame to be finished with PU polish in approved shade to the exposed faces, the frame face in contact with masonry shall be applied with black japan paint. The shutter shall be factory made 76mm thick insulated flush shutter of approved make confirming to IS 2202 (Part - I); Shutter shall be manufactured with exterior quality synthetic adhesive forming marine ply surfaces, internally lipped. Further shutter shall be finished with 4mm thick veneer finish including PU polish on both side of approved make, shade and design, hot pressed at factory, edges of shutter shall be provided with 6mm thick teakwood beadings using exterior quality synthetic adhesive, headless GI nails, screws, beading finished with PU polish, etc. Further providing and fixing ironmongeries as per schedule and drawings all complete to entire satisfaction of the PM. (Refer Door Schedule: A13-15,16)
6.10.1 Gallery Door (Type-4) D-A-G-03 (Orientation Gallery) & D-A-G-13 (Auditrium Exit), overall size 1800mm x 2400mm Nos 2.00 0
a) 5 Knl, Ball bearing offset hinges size 100 x 75 x 3mm, SSS - 6 Nos.
b) Narrow profile Mortise Dead lock, 35 BS/8mm, SSS finish with cyl, escutheion suitable for double leaf door
c) Concealed door closer, Medium duty EN 2-4 with std arm, Silver finish - 1 No. (on bigger leaf)
d) Concealed Flush Bolt L=300mm - 1 No. (on smaller leaf)
e) Lever Handle with roses & Escutcheons
6.10.2 Gallery Door (Type-3) D-F-G-02 (Temp. Gal), D-G-L-05, D-G-L-06 (Location : Utsah Gal-Entry, Exit) overall size 3000mm x 3600mm, out of which 1800mm wide x 2400mm high openable double leaf door, with approved 4mm thick veneer finished. Nos 3.00 0
a) 5 Knl, Ball bearing offset hinges size 100 x 75 x 3mm, SSS - 6 Nos.
b) Motorised locking system
c) Concealed door closer, Medium duty EN 2-4 with std arm, Silver finish - 1 No. (on bigger leaf)
d) Door stopper
e) Pull/Push handle
6.11 Providing and fixing Wooden partly fixed, partly openable, partly galzed door with approved 1st quality teak wood door frame of size 75mm x 250mm size, fixed with holdfasts / dash fasteners / SS screws, frame to be finished with PU polish in approved shade to the exposed faces, the frame face in contact with masonry shall be applied with black japan paint. The shutter along with top fixed portion above shutter shall be factory made 76mm thick insulated flush shutter (with marine grade plywood 19mm thick on both sides and rock wool insulation inside) of approved make; Shutter shall be manufactured with exterior quality synthetic adhesive forming marine ply surfaces, internally lipped. Further shutter shall be finished with 4mm thick veneer finish including PU polish on both side of approved make, shade and design, hot pressed at factory, edges of shutter shall be provided with 6mm thick teakwood beadings using exterior quality synthetic adhesive, headless GI nails, screws, beading finished with PU polish, etc. The side fixed glazed panels shall be as per the drawing. Further providing and fixing ironmongeries as per schedule and drawings all complete to entire satisfaction of the PM. (Refer Door Schedule: A13-15,16)
6.11.1 Door (Type-3) D-A-1F-02 (Gaurav Gallery) overall size 3000mm x 3600mm. Double leaf openable wooden shutters of size 1800mm x 2400mm and top fixed portion with approved 4mm thick veneer finished in PU polish, both side portions with fixed glass (#3: Insulated (10mm + 16mm air gap + 8mm) 34mm thick DGU Nos 1.00 0
a) SS Floor springs
b) Narrow profile Mortise Dead lock, 35 BS/8mm, SSS finish with cyl, escutheion suitable for double leaf door
c) Pivots at top
d) Concealed Flush Bolt L=300mm - 1 No. (on smaller leaf)
e) Wooden handle made out of MS Tee section, 1800mm long - 2 x 2 Nos.
6.11.2 Door (Type-3A) D-B-G-02 (Multipurpose) overall size 2100mm x 2400mm. Double leaf openable shutters of size 1050mm x 2400mm, side portion fixed with glass (#3: Insulated (10mm + 16mm air gap + 8mm) 34mm thick DGU, and top portion fixed 75mm thick with approved 4mm thick veneer finished. Nos 1.00 0
a) SS Floor springs
b) Narrow profile Mortise Dead lock, 35 BS/8mm, SSS finish with cyl, escutheion suitable for double leaf door
c) Pivots at top
d) Concealed Flush Bolt L=300mm - 1 No. (on smaller leaf)
e) Wooden handle made out of MS Tee section, 1800mm long - 2 x 2 Nos.
6.12 Providing and fixing of following fully glazed door shutters out of 50mm thick x 100mm wide top, bottom rail and vertical style of 1st quality teakwood, kiln seasoned, antitermite treated, shaped, grooved rebated with required mating styles, joined with tongue and grooved mitered joints arrangement including use of approved water repellent exterior quality adhesive, SS Screws, pins, etc. Also to include two coats of wood primer, two under coats and one finished coat of synthetic enamel paint matt/gloss finish. Also to include 8mm thick toughened glass as detailed, required ironmongery shall be of best quality heavy duty Stainless steel as detailed for each shutters here under.
6.12.1 Door (Type-6) D-B-2F-01, 02, 03, 04, 06, 10, 14, 15, 18, 19, 20, 21, 22, 23, 24 (Location: SNR Admin, Meeting room, Director, Pantry, Documents lounge, File room, Accounts, BLD Management, Curatorial) Single leaf glass doors with overall size of 800mm x 2100mm height, with wooden frame and glass type #5 Insulated (6mm + 12mm + 5mm) 23mm glass with hinges, lever type handles, floor spring and door stopper, eye stop sticker as detailed in drawings. Nos 15.00 0
6.12.2 Door (Type-6) D-B-2F-07, D-B-2F-16 (Location : Reception, Conference) Single leaf glass doors with overall size of 1200mm x 2100mm height, with wooden frame and glass type #5 Insulated (6mm + 12mm + 5mm) 23mm with hinges, lever type handles, floor spring and door stopper, eye stop sticker as detailed in drawings. Nos 2.00 0
6.12.3 Door (Type-6) D-C-G-10 (Location : Restaurant counter) Single leaf glass doors with overall size of 750mm x 2100mm height, with wooden frame and glass type #7 Single pane 8mm thick glass with hinges, lever type handles, floor spring and door stopper as detailed in drawings. Nos 1.00 0
6.13 Providing and fixing toilet cubical systems of approved make and manufactured in standard dimensions of 600mm ± 10mm width door size with 12mm thick solid Compact Laminate panels made of KRAFT paper impregnated with Phenolic resins under high pressure and temperature, including doors, pilasters & intermediate panels, which should be resistant to heat, bacteria, water, chemical, scratch and impact. Finished product should be as per approved texture, shade & drawing, detailing and developed according to IS-2046 and BS-476/97 standards. The toilet cubicle setup shall include necessary hardware fittings, made out of stainless steel (Grade-304), as per manufacturer’s specifications and approved by Engineer-in-charge.
Hardware fittings should consist of (1) Stainless steel Adjustable foot/ pedestal of SS 316 grade to give 150mm clearance from bottom and of weight not less than 600grams (2) Stainless steel U-channels of 20 gauge and 12 x 20mm size (3) Stainless steel Top rail pipe (OD:24mm of 18 gauge) with corner connectors
(4) Stainless Steel Head Rail Tubular Holder (5) Stainless steel Gravity hinges (3 nos.) not less than 75mm length and weight not less than 210 grams of weight not less than 200 grams. (6) Stainless steel Coat hook with nylon door stopper (7) Stainless steel Door knob (8) Stainless steel Baby latch (9) Wall bracket SS 304 (10) Corner Connector (11) Rubber noise deafening tape (12) Stainless steel 304 Screws and PVC wall plugs.
The top fitting arrangement shall comprise of stainless steel (round) top rail, fixed to pilasters and stainless steel tubular holder. Stainless steel wall fixing roses shall be used on the wall to hold the top rail. In absence of brick walls, stainless steel corner bends (connected to the top rail) shall be used on the corners of the cubicle. All screws should be of stainless steel (Grade-304). All pilasters shall be supported by stainless steel adjustable foot. The base of the stainless steel bottom cladding shall be anchored to the floor with a clearance height of 150mm.The intermediate panel shall be of one continuous panel without any joint. All visible edges shall be chamfered.
6.13.1 a) L-Shape Toilet cubicle with standard dimensions of 2000 ± 25mm (Height) x 1000mm (Width) x 1550mm (Depth) consisting of 600 ± 10 mm width of door. The rate includes cost of 12mm Solid compact laminate board along with all necessary fixtures mentioned above. Nos 76.00 0
6.13.2 b) I - shape (front partition) Toilet cubicle with standard dimensions of 2000 ± 25mm (Height) x 1765mm (Width) consisting of 600 ± 10 mm width of door. The rate includes cost of 12mm Solid compact laminate board along with all necessary fixtures mentioned above Nos 39.00 0
6.14 VISION PANEL Size: 2.1m X 0.9m
6.14.1 CONTROL ROOM : VISION PANEL DETAILS (OPENABLE TYPE) 1. 2.layers of Gyproc Habito Board 12.5mm thick 2. Mass loaded Vinyl 3.5mm 3. Birch Plywood or Marine grade plywood with veneer melamine polished 4. Silicone Sealant at glass contact point with the ply/timber beading 5. Glazing panel at an angle of approx. 8-12 degrees as shown 6. Perforated aluminium or ply finish 7. Silica desiccant filling in packet format. Provision for future replacement to be ensured 8. Birch plywood OR marine grade plywood Note : All screws to be applied with silica gel while fastening for a complete seal through material boards. Decoupling Joint between the frame to achieve maximum transmission isolation to be ensured. FOR OPENABLE VISION PANEL : Recommended make >> Aluminium type with Laminated Glazed panel. Tostem Grants frame and installation. Sqm 1.95 0
6.15 AUDITORIUM DOORS D-A-G-05 (Auditorium Entracnce), D-A-G-10 (Auditrium Exit) Size: 1.8m X 2.4m
6.15.1 1. 2.5 mm thk TEXSA tecsound T50 2. 9 mm thk BWP plywood 3. Final finish as per internal material - 9-20 mm thk as per fixture detail 4. Perimeter seal SCHALL PS 1010 p along hinge end and top end of door frame 5. Tectus concealed hinge TE 6453d wt. Up to 300 kg or similar 6. 25x50 mm thk framework seasoned teakwood or Salwood as per architect's instruction 7. Outer finish on BWP plywood or birch ply with melamine polish as per architect's instruction thickness as per finish 8. All handles, Hinges and hardware to be considered in the Final Cost. Provision for Access control or special hardware if any shall be consider seperate Recommended Make: Soundworks, Acoustical Surfaces India Nos 2.00 0
6.16 AUDITORIUM DOORS-D-A-G-09 Size: 1.5m X 2.4m
6.16.1 1. 2.5 mm thk TEXSA tecsound T50 2. 9 mm thk BWP plywood 3. Final finish as per internal material - 9-20 mm thk as per fixture detail 4. Perimeter seal SCHALL PS 1010 p along hinge end and top end of door frame 5. Tectus concealed hinge TE 6453d wt. Up to 300 kg or similar 6. 25x50 mm thk framework seasoned teakwood or Salwood as per architect's instruction 7. Outer finish on BWP plywood or birch ply with melamine polish as per architect's instruction thickness as per finish 8. All handles, Hinges and hardware to be considered in the Final Cost. Provision for Access control or special hardware if any shall be consider seperate. Recommended Make: Soundworks, Acoustical Surfaces India Nos 1.00 0
6.17 CONTROL ROOM DOOR (Type-7) D-A-G-11 (Location : Control Room)
6.17.1 1. 2.5 mm thk TEXSA tecsound T50 2. 9 mm thk BWP plywood 3. Final finish as per internal material - 9-20 mm thk as per fixture detail 4. Perimeter seal SCHALL PS 1010 p along hinge end and top end of door frame 5. Tectus concealed hinge TE 6453d wt. Up to 300 kg or similar 6. 25x50 mm thk framework seasoned teakwood or Salwood as per architect's instruction 7. Outer finish on BWP plywood or birch ply with melamine polish as per architect's instruction thickness as per finish 8. All handles, Hinges and hardware to be considered in the Final Cost. Provision for Access control or special hardware if any shall be consider seperate. Recommended Make: Soundworks, Acoustical Surfaces India Nos 1.00 0
6.18 Control room window - VISION WINDOW W-A-G-02 to have following specs, Mention 2 glazing - 8 Degree 1. 2.layers of Gyproc Habito Board 12.5mm thick 2. Mass loaded Vinyl 3.5mm 3. Birch Plywood or Marine grade plywood with veneer melamine polished 4. Silicone Sealant at glass contact point with the ply/timber beading 5. Glazing panel at an angle of approx. 8-12 degrees as shown 6. Perforated aluminium or ply finish 7. Silica desiccant filling in packet format. Provision for future replacement to be ensured 8. Birch plywood OR marine grade plywood Sqm 4.00 0
TOTAL OF WOOD WORK 0
The rates shall include
a The structural steel frame work in line with design drawings made out of MS pipe sections / I Beams / Channels / Plates of approved make make of first quality confirming to IS standard.
b Preparing shop drawings based on architectural and structural drawings with required connections, all conforming to standards, code of practices, instructions of Structural consultant/PM.
c Take actual site measurement prior to fabrication and incorporate into shop drawings accordingly.
d Coordinating, scheduling and doing works as per site program.
e Straightening, cutting, bolting, welding including layout and assembly.
f Erecting, aligning, making plum and leveling to correct position as per shop drawings including required site repairs/adjustments.
g The steel structure shall be finish with the following, i. Surface Preparation – Blast cleaned to Sa 2.5 confirming to BS EN ISO 8501-1 ii. Primer : Zinc Rich Epoxy 75 micron iii. Barrier : Epoxy Mio 125 micron iv. Finish : Polyurethane – 50 Micron (Only for exposed steel)
h The steel design shall accommodate thermal stresses resulting from thermal expansion due to surface temperatures.
i Refer door schedule drawing no-A13-10 for type of finishes on particular door.
7.1A Steel work, welded in built up sections framed work including cutting, hoisting, fixing in position and applying a priming coat of red lead paint. (D) In trussses and trussed purlins. Kg 4,064,968.00 0
7.1B Structural steel work (Confirming to IS 4923 latest version: Hollow Steel Sections for structural use) riveted, bolted or welded in builtup for all type sections, in framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete as per the structural designs and directions of Engineer in charge. Kg 48,647.00 0
7.2 Do as above but for steel work in Structural column of covered walkway - specialised CNC fabrication. Refer A16-06 Kg 25,703.00 0
7.3 Providing, fabricating and fixing G.I. railing system of approved design and profile, comprising vertical posts made of 38 mm dia G.I. pipes (1.2 mm thick), horizontal members of 19 mm dia G.I. pipes, and intermediate supports using G.I. flats (12 x 50 mm) at spacing of 1500 mm c/c, including necessary G.I. pipe plugs (16 mm dia) and all associated components as per approved drawings. Rmt 58.00 0
The work shall include cutting, bending, welding, grinding, and finishing of all members to achieve smooth and uniform joints, including factory welding and grinding smooth at connections. The railing shall be fixed to floor/structural base using suitable base plates, anchor fasteners, bolts, and necessary fixtures as approved by the Engineer-in-Charge, ensuring proper alignment, level, and rigidity.
The item shall include providing all materials, labour, tools and tackles, scaffolding, transportation, loading/unloading, and all incidental charges required to complete the work in accordance with approved shop drawings and specifications. The contractor shall prepare and submit detailed shop drawings for approval prior to execution. All complete as per drawings, specifications, and direction of Engineer-in-Charge. Note: For payment, only the weight of G.I. steel members shall be measured; fixing accessories such as nuts, bolts, fasteners, etc., shall not be measured separately. (refer-Detail-7-A12-12 & 07/A7-22)
7.4 Providing, fabricating and fixing S.S 304 Grade about 300mm high from finished floor level made out of 38mm dia SS pipe as handrail fixed to 10 x 50mm vertical MS flat and SS plate at bottom as shown in the drawing. Rate shall including including fabricating, fixtures, erecting, necessary welding, grinding, finishing, buffing to stainless steel pipe, providing and applying approved compatible primer and enamel paint to MS flat etc. including preparing shop drawings with prior approval of Architect / Engineer in charge etc. (Location : Glazing gaurd Railing) (refer-A12-12 & 03/A7-22) Rmt 252.00 0
7.5 Providing, fabricating and fixing double handle wooden railing about 800 mm high from finished floor level, comprising 38mm dia. wooden top rail fixed over MS support system as shown in drawing, including 20 × 10 mm MS flat cut to shape (2 Nos), 45 × 10 mm MS flat (2 Nos) for vertical supports, and 25 × 25 × 100 mm MS solid spacers in between at required intervals. The work includes supplying and fixing all components complete with necessary welding, cutting, drilling, grinding and finishing of MS members, providing and applying approved primer and enamel paint to all MS surfaces, and polishing/finishing of wooden railing with approved coating. Item to include all fixtures, fasteners, erection, and preparing shop drawings with prior approval of Architect/Engineer-in-charge, complete as per drawing and site requirements.(refer-A12-12 & 06/A7-22) Rmt 9.00 0
7.6 Providing, fabricating and fixing wall-mounted S.S. 304 grade railing at about 900 mm height from finished floor level, made out of 38 mm dia stainless steel pipe fixed to wall with suitable SS brackets as per drawing. The item shall include all necessary fixtures, anchor fasteners, welding, cutting, grinding, polishing and buffing to achieve stainless steel finish, complete in all respects. Rate shall include preparing shop drawings and obtaining prior approval of Architect /Engineer-in-charge, complete as per drawings and site requirements.(refer-A12-12 & 01/A7-22) Rmt 1,263.00 0
7.7 Providing, fabricating and fixing wall-mounted wooden railing at about 900 mm height from finished floor level, made out of 38 mm dia wooden member with approved polish finish, fixed to wall using suitable SS brackets as shown in drawing. The work shall include all fixtures, fasteners, necessary cutting, fitting, finishing, polishing, and providing and applying approved primer and enamel paint to MS components. Item includes erection, preparation of shop drawings and approval from Architect/Engineer-in-charge, complete as per drawings and site requirements.(refer-A12-12 & 02/A7-22) Rmt 183.00 0
7.8 Providing, fabricating and fixing wall-mounted wooden handrail system at a height of 1100 mm from finished floor level, comprising 38 mm diameter hardwood railing with approved polish finish, supported on stainless steel brackets anchored to wall, Further 1500mm c/c clamps to fixed glass as per approved drawings. The scope shall include 10 mm thick tempered laminated glass panel fixed in suitable glazing shoe/box with necessary sealant, MS backing plates, trims, and stainless steel fasteners as required. Wooden handrail shall be properly fixed over glass using approved connectors. All MS components shall be treated with approved primer and finished with enamel paint. The work includes all materials, labour, cutting, fitting, edge finishing, polishing, sealant application, hardware, and accessories required for complete installation. Item also includes preparation of shop drawings, obtaining approvals from Architect/Engineer-in-charge, and execution strictly as per drawings, specifications, and site conditions.(refer-A12-12 & 09/A7-22) Rmt 158.00 0
7.9 Providing and fixing wooden grab rail comprising 70 mm dia hardwood member with approved veneer finish, fixed at 900 mm height from finished floor level, supported on MS/GI sub-structure anchored to wall, including 15 mm thick plywood backing with veneer finish, SS/MS brackets, fasteners, and all necessary hardware. The item includes cutting, fitting, finishing, polishing, and application of primer and enamel paint to MS components, complete as per drawings and specifications.(refer-A12-12 & 10/A7-22) Rmt 455.00 0
7.10 Providing, fabricating and fixing fixed glass railing system comprising 10 mm thick tempered laminated safety glass panels, securely fixed in continuous aluminium shoe box with necessary gaskets, sealant, and anchoring arrangement as per approved drawings. The glass panels shall be finished with stainless steel capping at top, properly aligned and fixed. The base shoe shall be supported on MS flat (150 x 9 mm) with approved primer and enamel paint, anchored to RCC base, and integrated with surrounding stone dry cladding as shown.The work shall include all materials, labour, cutting, edge finishing, polishing, drilling, grouting, application of sealant, SS fasteners, and accessories required for complete installation. All exposed metal components shall be finished to approved specifications. The item includes preparation of shop drawings, obtaining approvals from Architect/Engineer-in-charge, and execution strictly as per drawings, specifications, and site conditions, complete in all respects.(refer-A12-12 & 08/A7-22) Rmt 38.00 0
7.11 Providing and fixing 2mm thick SS coping about 225mm wide at top of parapet top with necessary accessories as shown in drawing. (Refer-A12-08 & Detail A11-01) Rmt 126.00 0
7.12 Non-fire rated Hollow metal doors
Providing and fixing of Standard duty Hollow metal doors confirming to IS 16074 & IS 4351 made of pressed galvanized steel confirming to IS 277 with the following specification. Doors shall be manufcatured in ISO 9001: 2015 certified company for quality management. Doors shall be with vision glass and louver as a part of complete assembly.
Door frame shall be single rebate grooved profile of size 125 x 55mm made out of minimum 1.20mm (18gauge) thick galvanized steel sheet. Frames shall be mitered only. Frames shall be field assembled with self tabs. Bolted & butted joints are not acceptable. Frames to have inbuild grooved sealing system with appropriate PVC seal. All provision should be mortised, drilled and tapped for receiving appropriate hardware. Frames should be provided with back plate bracket and anchor fasteners for installation on a finished plastered masonry wall opening. once frames installed it should be grouted with non fire rated PUF.
Door leaf shall be 46mm thick fully flush double skin door, with or without vision lite. Door leaf shall be manufactured from minimum 0.8mm (22guage) thick galvanised steel sheet. The internal construction of the door should be rigid reinforcement pads for receiving appropriate hardware. The infill material shall be resin bonded honeycomb core. The edges should be interlocked with a bending radius of 1.4mm. For pair of doors integrated astragals has to be provided on the meeting stile for both active and inactive leaf. Vision lite wherever applicable should be provided a clipon arrangement. Glass shall be minimum 4mm clear toughned glass with suitable gaskets as per manufacturers recommendation with a clipon arrangement.
All doors and frames shall be finished Pure Polyester Powder coated and shall have passed minimum 500 hours of salt sprey test.
Rate shall include supply and installation of frame, shutter as a complete assembly. All hardware, seals & glass including tapes cost will be paid extra as per the hardware schedule
7.12.1 Door DS-A-L-01, DS-B-1F-05, DS-F-G-04, DS-G-G-03, DS-J-L-09, DS-J-G-05, DS-J-1F-05, DS-J-1F-07, D-M-G-01, D-M-G-02 (Location PHE Shaft, Toilet-Male & Female), sigle leaf, size 600mm x 1500mm, with SS hardware of approved make Nos 10.00 0
a) 5 Knl, Ball bearing hinges size 100 x 75 x 3mm, SSS - 3 Nos.
b) Allen key Dead lock
7.12.2 Door (Type-8) D-A-G-06, D-A-G-07 (Location Audi Green Room Toilets), D-J-L-20, D-J-L-21 (Location : Staff Toilet-M & F), sigle leaf, size 750mm x 2100mm, with SS hardware of approved make Nos 4.00 0
a) 5 Knl, Ball bearing hinges size 100 x 75 x 3mm, SSS - 3 Nos.
b) Cylindrical lock with knobs, push button inside, emergency opening outside
c) Surface door closer
d) Door stopper
7.12.3 Door (Type-7) D-B-1F-04, D-F-G-07, D-G-L-08, D-G-G-07, D-J-L-18, D-J-1F-10, D-M-G-02 (Location : Janitor room), D-B-2F-05 (Location : Director Toilet), (Location : Staff Toilet-M & F), sigle leaf, size 750mm x 2100mm, with SS hardware of approved make Nos 8.00 0
a) 5 Knl, Ball bearing hinges size 100 x 75 x 3mm, SSS - 3 Nos.
b) Cylindrical lock with knobs, push button inside, emergency opening outside
c) Surface door closer
d) Door stopper
7.12.4 Door (Type-7A) D-B-L-01 (Location : Security Monitor), size 1200mm x 2100mm, with double unequal leaves door shutters (900mm + 300mm) with SS hardware of approved make Nos 1.00 0
a) 5 Knl, Ball bearing hinges size 100 x 75 x 3mm, SSS - 6 Nos.
b) Cylindrical lock with knobs and key opening
c) Surface door closer, Medium duty EN 2-4 with std arm, Silver finish - 1 No. (on bigger leaf)
d) Concealed Flush Bolt L=300mm - 1 No. (on smaller leaf)
7.12.5 Door (Type-7B)D-A-G-12, (Location Service Passage), size 1500mm x 2100mm, with double leaf door shutters with SS hardware of approved make Nos 1.00 0
a) 5 Knl, Ball bearing hinges size 100 x 75 x 3mm, SSS - 6 Nos.
b) Cylindrical lock with knobs and key opening
c) Surface door closer, Medium duty EN 2-4 with std arm, Silver finish - 1 No. (on one leaf)
d) Concealed Flush Bolt L=300mm - 1 No. (on other leaf)
7.12.6 Door (Type-7A) D-J-L-04 (Location Service Passage), size 1500mm x 2100mm, with double leaf door shutters with SS hardware of approved make Nos 1.00 0
a) 5 Knl, Ball bearing hinges size 100 x 75 x 3mm, SSS - 6 Nos.
b) Cylindrical lock with knobs and key opening
c) Surface door closer, Medium duty EN 2-4 with std arm, Silver finish - 1 No. (on one leaf)
d) Concealed Flush Bolt L=300mm - 1 No. (on other leaf)
7.12.7 Door (Type-DS1) DS-A-G-02 (Location PHE Shaft), sigle leaf, size 600mm x 1800mm, with 35mm thick sand stone cladding on outer face, SS hardware of approved make Nos 1.00 0
a) 5 Knl, Ball bearing hinges size 100 x 75 x 3mm, SSS - 3 Nos.
b) Allen key Dead lock
c) Concealed handle
7.12.8 Door (Type-DS1) DS-B-2F-03, DS-J-1F-09 (Location PHE Shaft), sigle leaf, size 600mm x 1800mm, with SS hardware of approved make Nos 2.00 0
a) 5 Knl, Ball bearing hinges size 100 x 75 x 3mm, SSS - 3 Nos.
b) Allen key Dead lock
c) Concealed handle
7.12.9 Door (Type-DS1) DS-A-G-03, DS-J-L-03, DS-J-L-04,DS-A-1F-03, DS-J-2F-03, DS-J-4F-03, D-B-1F-02 (Location PHE Shaft), sigle leaf, size 600mm x 1800mm, with SS hardware of approved make Nos 7.00 0
a) 5 Knl, Ball bearing hinges size 100 x 75 x 3mm, SSS - 3 Nos.
b) Allen key Dead lock
c) Concealed handle
7.12.10 Door D-A-1F-04, D-C-1F-01, D-F-G-03, D-G-L-01, D-G-G-02, D-G-1F-01, D-J-L-14, D-J-G-04, D-J-1F-07, D-J-2F-03 (Location: Service Passage, Bontiful Gallery-BOH, Temp Gal-Serv, Utsah Gal-BOH, Siddhi Gal-BOH), size 2700mm x 3000mm, with double unequal leaves door shutters (1200mm + 1500mm) with pait finished 12mm thick gypsum board + 12mm thick Plywood backing on one side of the door, including SS hardware of approved make Nos 5.00 0
a) 5 Knl, Ball bearing offset hinges heavy duty size 150 x 100 x 3mm, SSS - 6 Nos.
b) Provision for Access control
c) Concealed door closer, Medium duty EN 2-4 with std arm, Silver finish - 1 No. (on bigger leaf)
d) Concealed Flush Bolt L=300mm - 1 No. (on smaller leaf)
7.12.11 Door DS-A-2F-02 (Location PHE Shaft), sigle leaf, size 600mm x 2100mm, with 35mm thick stone cladding on outer face, SS hardware of approved make Nos 1.00 0
a) 5 Knl, Ball bearing hinges size 100 x 75 x 3mm, SSS - 3 Nos.
b) Allen key Dead lock
c) Concealed handle
7.12.12 Door (Type-7) D-B-L-04 (Location : Staff Break room), & D-B-L-07 (Location : Industrial First Aid) & D-B-M-02 (Location : Security), D-C-G-01 (Location : baby care), D-F-1F-07 (Location : Janitor room), D-J-L-17, D-J-G-08 (Location : Baby care), D-J-3F-02 (Location : Service passage), D-J-4F-13 (Location : Kitchen terrace), D-J-4F-14 (Location : Bakery+storage), D-K-G-02 (Location : Store), D-K-G-05 (Location : Service door), D-V-G-01 (Location : Security cabin) size 900mm x 2100mm, with signle leaf door shutters with SS hardware of approved make Nos 12.00 0
a) 5 Knl, Ball bearing hinges size 100 x 75 x 3mm, SSS - 3 Nos.
b) Cylindrical lock with knobs and key opening
c) Surface door closer, Medium duty EN 2-4 with std arm, Silver finish - 1 No. (on one leaf)
d) Concealed Flush Bolt L=300mm - 1 No. (on other leaf)
e) Lever Handle
7.12.13 Door (Type-7) D-B-L-06 (Location: Security locker, access door), size 900mm x 2100mm, with single leaf door shutters with SS hardware of approved make Nos 1.00 0
a) 5 Knl, Ball bearing offset hinges heavy duty size 150 x 100 x 3mm, SSS - 3 Nos.
b) Provision for Access control
c) Concealed door closer, Medium duty EN 2-4 with std arm, Silver finish - 1 No.
d) Concealed Flush Bolt L=300mm - 1 No. (on smaller leaf)
e) Lever Handle with roses & Escutcheons
7.12.14 Door (Type-8) D-B-L-08, D-B-L-09, D-B-M-08, D-B-M-09, D-B-2F-12, D-B-2F-13, (Location: Staff Toilet M & F, Staff Lokcer room, Toilet male & Female, Kitchen admin), size 900mm x 2100mm, with single leaf door shutters with SS hardware of approved make Nos 6.00 0
a) 5 Knl, Ball bearing offset hinges heavy duty size 150 x 100 x 3mm, SSS - 3 Nos.
b) Cylindrical lock with knobs and key opening
c) Surface door closer
d) Lever Handle
7.12.15 Door (Type-7) D-B-M-07, D-B-M-10, D-J-4F-11, D-K-G-03 (Location: Staff Toilet M & F, Staff Lokcer room, Toilet male & Female, Kitchen admin), size 900mm x 2100mm, with single leaf door shutters with SS hardware of approved make Nos 4.00 0
a) 5 Knl, Ball bearing offset hinges heavy duty size 150 x 100 x 3mm, SSS - 3 Nos.
b) Cylindrical lock with knobs and key opening
c) Surface door closer
d) Lever Handle
7.12.16 Door (Type-7A) D-B-L-10 (Location : Storage, AV Store), size 1200mm x 2100mm, with double unequal leaves door shutters (900mm + 300mm) with fire rated SS hardware of approved make Nos 1.00 0
a) 5 Knl, Ball bearing hinges size 100 x 75 x 3mm, SSS - 6 Nos.
b) Cylindrical lock with knobs and key opening
c) Concealed door closer, Medium duty EN 2-4 with std arm, Silver finish - 1 No.
d) Lever Handle
7.12.17 Door (Type-7) D-B-L-11 (Location : Janitor room), size 750mm x 2100mm,with single leaf door shutters with SS hardware of approved make Nos 1.00 0
a) 5 Knl, Ball bearing hinges size 100 x 75 x 3mm, SSS - 6 Nos.
b) Cylindrical lock with knobs and key opening
c) Concealed door closer, Medium duty EN 2-4 with std arm, Silver finish - 1 No.
d) Lever Handle
7.12.18 Door (Type-7B) D-B-L-13 (Location : Waste Management), size 1500mm x 2100mm, with double equal leaves door shutters (750mm + 750mm) with fire rated SS hardware of approved make Nos 1.00 0
a) 5 Knl, Ball bearing hinges size 100 x 75 x 3mm, SSS - 6 Nos.
b) Lever Handle with roses & Escutcheons
c) heavy duty floor springs of adequate capacity
7.12.19 Door (Type-DS1) DS-B-1F-01, DS-B-1F-03, DS-F-1D-04 (Location PHE Shaft), sigle leaf, size 900mm x 1500mm, with SS hardware of approved make Nos 3.00 0
a) 5 Knl, Ball bearing hinges size 100 x 75 x 3mm, SSS - 3 Nos.
b) Allen key Dead lock
c) Concealed handle
7.12.20 Door DS-B-L-01 (Location : PHE Shaft), sigle leaf, size 600mm x 1500mm, with SS hardware of approved make Nos 1.00 0
a) 5 Knl, Ball bearing hinges size 100 x 75 x 3mm, SSS - 3 Nos.
b) Allen key Dead lock
c) Concealed handle
7.12.21 Door (Type-7A) D-B-M-01 (Location: Housekeeping), size 1200mm x 2100mm, with double unequal leaves door shutters (900mm + 300mm) with including SS hardware of approved make Nos 1.00 0
a) 5 Knl, Ball bearing offset hinges heavy duty size 150 x 100 x 3mm, SSS - 6 Nos.
b) Cylindrical lock with knobs and key opening
c) Concealed door closer, Medium duty EN 2-4 with std arm, Silver finish - 1 No.
d) Lever Handle
7.12.22 Door (Type-7B) D-B-M-05 (Location: Staff Ent/Fire Exit, access door), size 1800mm x 2100mm, with double equal leaf door shutters (900mm + 900mm) with SS hardware of approved make Nos 1.00 0
a) 5 Knl, Ball bearing offset hinges heavy duty size 150 x 100 x 3mm, SSS - 6 Nos.
b) Provision for Access control
c) Concealed door closer, Medium duty EN 2-4 with std arm, Silver finish - 1 No.
d) Concealed Flush Bolt L=300mm - 1 No. (on smaller leaf)
e) Lever Handle with roses & Escutcheons
7.12.23 Door (Type-7) D-B-M-06, D-C-G-04 (Location: Janitor room, Kitchen changing room), sigle leaf, size 750mm x 2100mm, with SS hardware of approved make Nos 2.00 0
a) 5 Knl, Ball bearing hinges size 100 x 75 x 3mm, SSS - 3 Nos.
b) Cylindrical lock with knobs and key opening
c) Surface door closer
d) Door stopper
e) Lever Handle
7.12.24 Door (Type-DS1) DS-B-L-02, DS-B-M-02, DS-B-G-02 (Location : FF shaft, Plumbing Shaft), sigle leaf, size 900mm x 1500mm, with SS hardware of approved make Nos 3.00 0
a) 5 Knl, Ball bearing hinges size 100 x 75 x 3mm, SSS - 3 Nos.
b) Allen key Dead lock
c) Concealed handle
7.12.25 Door (Type-DS1) DS-B-M-03, DS-B-G-05 (Location :Plumbing Shaft), sigle leaf, size 600mm x 1500mm, with SS hardware of approved make Nos 2.00 0
a) 5 Knl, Ball bearing hinges size 100 x 75 x 3mm, SSS - 3 Nos.
b) Allen key Dead lock
c) Concealed handle
7.12.26 Door (Type-7) D-B-G-03, D-B-G-04, D-B-G-11, D-B-G-12, D-B-1F-05, D-B-1F- 06, D-F-G-05, D-F-G-06, D-F-1F-08, D-F-1F-09, D-G-L-07, D-G-L-09, D-G-G-08, D-G-G-09, D-J-L-15, D-J-L-16, D-J-G-07, D-J-G-10, D-J-1F-03, D-J-1F-05, D-J-1F-09, D-J-1F-11, D-J-2F-04, D-J-2F-05, D-J-4F-02, D-J-4F-05, D-M-G-01, D-M-G-03 (Location Toilet Female & Male), sigle leaf, size 900mm x 2400mm, with SS hardware of approved make Nos 28.00 0
a) 5 Knl, Ball bearing hinges size 100 x 75 x 3mm, SSS - 3 Nos.
b) Cylindrical lock with knobs, push button inside, emergency opening outside
c) Concealed door closer, Medium duty EN 2-4 with std arm, Silver finish - 1 No.
d) Door stopper
7.12.27 Door (Type-7B) D-B-G-06 (Location: Furniture store), size 1500mm x 2400mm, with double equal leaves door shutters (750mm + 750mm) with pait finished 12mm thick gypsum board + 12mm thick Plywood backing on one side of the door, including SS hardware of approved make Nos 1.00 0
a) 5 Knl, Ball bearing offset hinges heavy duty size 150 x 100 x 3mm, SSS - 6 Nos.
b) Cylindrical lock with knobs and key opening
c) Concealed door closer, Medium duty EN 2-4 with std arm, Silver finish - 1 No. (on bigger leaf)
d) Concealed Flush Bolt L=300mm - 1 No. (on smaller leaf)
7.12.28 Door (Type-7A) D-B-G-07 (Location: Service passage), size 2700mm x 3000mm, with double unequal leaves door shutters (1200mm + 1500mm) with pait finished 12mm thick gypsum board + 12mm thick Plywood backing on one side of the door, including SS hardware of approved make Nos 1.00 0
a) 5 Knl, Ball bearing offset hinges heavy duty size 150 x 100 x 3mm, SSS - 6 Nos.
b) Cylindrical lock with knobs and key opening
c) Concealed door closer, Medium duty EN 2-4 with std arm, Silver finish - 1 No. (on bigger leaf)
d) Concealed Flush Bolt L=300mm - 1 No. (on smaller leaf)
7.12.29 Door (Type-7A) D-J-L-02 (Location: Service passage), size 2700mm x 3000mm, with double unequal leaves door shutters (1200mm + 1500mm) with SS hardware of approved make Nos 1.00 0
a) 5 Knl, Ball bearing offset hinges heavy duty size 150 x 100 x 3mm, SSS - 6 Nos.
b) Cylindrical lock with knobs and key opening
c) Concealed door closer, Medium duty EN 2-4 with std arm, Silver finish - 1 No. (on bigger leaf)
d) Concealed Flush Bolt L=300mm - 1 No. (on smaller leaf)
e) Access control
f) Pull/Push handle
7.12.30 Door (Type-7) D-B-G-10 Location : Janitor room), sigle leaf, size 750mm x 2100mm, with SS hardware of approved make Nos 1.00 0
a) 5 Knl, Ball bearing hinges size 100 x 75 x 3mm, SSS - 3 Nos.
b) Cylindrical lock with knobs, push button inside, emergency opening outside
c) Surface door closer
d) Door stopper
7.12.31 Door DS-B-G-01 (Location PHE Shaft), sigle leaf, size 600mm x 1800mm, with SS hardware of approved make Nos 1.00 0
a) 5 Knl, Ball bearing hinges size 100 x 75 x 3mm, SSS - 3 Nos.
b) Allen key Dead lock
7.12.32 Door (Type-7A) D-B-G-07 (Location: Service passage), size 2700mm x 3000mm, with double unequal leaves door shutters (1200mm + 1500mm) with pait finished 12mm thick gypsum board + 12mm thick Plywood backing on one side of the door, including SS hardware of approved make Nos 1.00 0
a) 5 Knl, Ball bearing offset hinges heavy duty size 150 x 100 x 3mm, SSS - 6 Nos.
b) Provision for Access control
c) Concealed door closer, Medium duty EN 2-4 with std arm, Silver finish - 1 No. (on bigger leaf)
d) Concealed Flush Bolt L=300mm - 1 No. (on smaller leaf)
e) Pull/Push handle
7.12.33 Door (Type-DS2) DS-B-2F-02 (Location PHE Shaft), sigle leaf, size 1200mm x 1800mm, with double equal leaves door shutter (600mm x 600mm), with SS hardware of approved make Nos 1.00 0
a) 5 Knl, Ball bearing hinges size 100 x 75 x 3mm, SSS - 6 Nos.
b) Allen key Dead lock
c) Concealed handle
7.12.34 Door (Type-7A) D-C-L-01 (Location : Wet waste), sigle leaf, size 1500mm x 2100mm, with double unequal leaves door shutter (900mm + 600mm) with SS hardware of approved make Nos 1.00 0
a) 5 Knl, Ball bearing hinges size 100 x 75 x 3mm, SSS - 6 Nos.
b) Cylindrical lock with knobs, push button inside, emergency opening outside
c) Surface door closer
d) Door stopper
7.12.35 Door (Type-7B) D-C-G-02, D-E-1F-02, D-F-1F-04 (Location : Kitchen-BOH, AHU Entry, Pantry-BOH), size 1500mm x 2100mm, with double equal leaves door shutters (750mm + 750mm) with fire rated SS hardware of approved make Nos 3.00 0
a) 5 Knl, Ball bearing hinges size 100 x 75 x 3mm, SSS - 6 Nos.
b) Cylindrical lock with knobs, push button inside, emergency opening outside
c) Lever Handle with roses & Escutcheons
d) Surface door closer
7.12.36 Door (Type-12) D-C-G-07, D-C-G-08 (Location : Kitchen), size 1500mm x 2100mm, with double equal leaves door shutters (750mm + 750mm) with fire rated SS hardware of approved make Nos 2.00 0
a) 5 Knl, Ball bearing hinges size 100 x 75 x 3mm, SSS - 6 Nos.
b) Pull / Push handle
c) heavy duty floor springs of adequate capacity
d) Door stopper
e) Vision panel-300mm x 300mm
7.12.37 Door (Type-12) D-C-G-09 (Location : Kitchen-FOH), size 1800mm x 2100mm, with double equal leaves door shutters (900mm + 900mm) with fire rated SS hardware of approved make Nos 1.00 0
a) 5 Knl, Ball bearing hinges size 100 x 75 x 3mm, SSS - 6 Nos.
b) Pull / Push handle
c) heavy duty floor springs of adequate capacity
d) Door stopper
e) Vision panel-300mm x 300mm
7.12.38 Door (DS-3)DS-C-G-02, DS-G-L-02 (Location : PHE Shaft), sigle leaf, size 900mm x 1500mm, with double unequal leaves shutter (600mm + 300mm) with SS hardware of approved make Nos 2.00 0
a) 5 Knl, Ball bearing hinges size 100 x 75 x 3mm, SSS - 3 Nos.
b) Allen key Dead lock
c) Concealed handle
7.12.39 Door (Type-7B) D-B-G-06 (Location: Furniture store), size 1500mm x 2400mm, with double equal leaves door shutters (750mm + 750mm) with SS hardware of approved make Nos 1.00 0
a) 5 Knl, Ball bearing offset hinges heavy duty size 150 x 100 x 3mm, SSS - 6 Nos.
b) Cylindrical lock with knobs and key opening
c) Concealed door closer, Medium duty EN 2-4 with std arm, Silver finish - 1 No. (on bigger leaf)
d) Concealed Flush Bolt L=300mm - 1 No. (on smaller leaf)
7.12.40 Door (Type-7A) D-F-G-04 (Location: Temp Gal-Serv), size 2700mm x 3000mm, with double unequal leaves door shutters (1200mm + 1500mm) with 35mm thick sand stone fire rated SS hardware of approved make Nos 1.00 0
a) 5 Knl, Ball bearing offset hinges heavy duty (suitable to take additional load of sand stone) size 100 x 75 x 3mm, SSS - 6 Nos.
b) Narrow profile Mortise Dead lock, 35 BS/8mm, SSS finish with cyl, escutheion suitable for double leaf door
c) Concealed door closer, Medium duty EN 2-4 with std arm, Silver finish - 1 No. (on bigger leaf)
d) Concealed Flush Bolt L=300mm - 1 No. (on smaller leaf)
e) Lever Handle with roses & Escutcheons
7.12.41 Door (Type-7B) D-F-G-10 (Location : Service passage), size 3000mm x 3000mm, with Double leaf equal door shutters (1500mm + 1500mm) with fire rated SS hardware of approved make Nos 1.00 0
a) 5 Knl, Ball bearing hinges size 100 x 75 x 3mm, SSS - 6 Nos.
b) Cylindrical lock with knobs and key opening
c) Surface door closer, Medium duty EN 2-4 with std arm, Silver finish - 1 No. (on one leaf)
d) Concealed Flush Bolt L=300mm - 1 No. (on other leaf)
e) Lever Handle
7.12.42 Door (Type-7B) D-F-1F-02, D-F-1F-03 (Location : Storage, VIP lounge-Pantry), size 1500mm x 2400mm, with double equal leaf door shutter (750mm + 750mm) with 12mm thick Plywood backing on one side of the door finish with approved 4mm thick veneer finish with SS hardware of approved make Nos 2.00 0
a) 5 Knl, Ball bearing hinges size 100 x 75 x 3mm, SSS - 3 Nos.
b) Cylindrical lock with knobs and key opening
c) Concealed door closer, Medium duty EN 2-4 with std arm, Silver finish - 1 No. (on bigger leaf)
d) Concealed Flush Bolt L=300mm - 1 No. (on smaller leaf)
e) Lever Handle
7.12.43 Door (Type-7B) D-F-1F-05 (Location : Service passage), sigle leaf, size 1200mm x 2400mm, with double equal leaves door shutter (600mm + 600mm) with SS hardware of approved make Nos 1.00 0
a) 5 Knl, Ball bearing hinges size 100 x 75 x 3mm, SSS - 6 Nos.
b) Cylindrical lock with knobs, push button inside, emergency opening outside
c) Surface door closer
d) Door stopper
7.12.44 Door (Type-3) D-F-1F-12 (Location VIP Lounge-Entry), overall size 3000mm x 2400mm, with double equal leaf door shutter (900mm + 900mm) with 12mm thick Plywood backing on one side of the door finish with approved 4mm thick veneer finish with SS hardware of approved make Nos 1.00 0
a) 5 Knl, Ball bearing hinges size 100 x 75 x 3mm, SSS - 6 Nos.
b) Motorised dead lock
c) Concealed door closer, Medium duty EN 2-4 with std arm, Silver finish - 1 No.
d) Pull/Push handle
7.12.45 Door (DS-1) DS-F-1F-01 (Location : Electrical Shaft), sigle leaf, size 900mm x 1800mm, with SS hardware of approved make Nos 1.00 0
a) 5 Knl, Ball bearing hinges size 100 x 75 x 3mm, SSS - 3 Nos.
b) Allen key Dead lock
c) Concealed handle
7.12.46 Door (Type-3) D-G-G-03, D-G-G-06, D-G-1F-02, D-G-1F-06, D-J-L-08 (Location : Utsah Gal-FOH, Bontiful Gujarat bridge ), overall size 3000mm x 3600mm, out of which 1800mm wide x 2400mm high openable double leaf door with 12mm thick Plywood backing on one side of the door finish with approved 4mm thick veneer finish with SS hardware of approved make Nos 5.00 0
a) 5 Knl, Ball bearing offset hinges heavy duty (suitable to take additional load of sand stone) size 100 x 75 x 3mm, SSS - 6 Nos.
b) Pull/Push handle
c) Concealed door closer, Medium duty EN 2-4 with std arm, Silver finish - 1 No.
d) Door stopper
7.12.47 Door (Type-7) D-G-G-04, D-J-L-10, D-J-G-12, D-J-1F-13, D-J-2F-08, D-K-G-01, D-K-G-04, D-K-G-05, D-L-G-01, D-L-G-02 (Location : Kiosk, AV Shaft, Ticketing counter, Clock room, Service door, Security cabin), sigle leaf, size 900mm x 2400mm, with 12mm thick Plywood backing on one side of the door finish with approved 4mm thick veneer finish with SS hardware of approved make Nos 9.00 0
a) 5 Knl, Ball bearing hinges size 100 x 75 x 3mm, SSS - 3 Nos.
b) Cylindrical lock with knobs, push button inside, emergency opening outside
c) Concealed door closer, Medium duty EN 2-4 with std arm, Silver finish - 1 No.
d) Door stopper
e) Lever handle
7.12.48 Door (Type-7A) D-J-G-02 (Location : Service passage), sigle leaf, size 1200mm x 2400mm, with double unequal leaves door shutter (900mm + 300mm) with SS hardware of approved make Nos 1.00 0
a) 5 Knl, Ball bearing hinges size 100 x 75 x 3mm, SSS - 6 Nos.
b) Cylindrical lock with knobs, push button inside, emergency opening outside
c) Concealed door closer
d) Door stopper
e) Lever handle
7.12.49 Door (Type-7B) D-J-1F-04, D-J-1F-06, D-J-2F-06 (Location : Service passage, Baby care), sigle leaf, size 900mm x 2400mm, with double equal leaves door shutter (450mm + 450mm) with SS hardware of approved make Nos 3.00 0
a) 5 Knl, Ball bearing hinges size 100 x 75 x 3mm, SSS - 6 Nos.
b) Cylindrical lock with knobs, push button inside, emergency opening outside
c) Surface door closer
d) Door stopper
e) Lever handle
7.12.50 Door (Type-7) D-J-G-09, D-J-4F-04 (Location : Janitor room), size 750mm x 2400mm, with Single leaf door shutters with fire rated SS hardware of approved make Nos 2.00 0
a) 5 Knl, Ball bearing hinges size 100 x 75 x 3mm, SSS - 3 Nos.
b) Cylindrical lock with knobs and key opening
c) Surface door closer, Medium duty EN 2-4 with std arm, Silver finish - 1 No. (on one leaf)
d) Concealed Flush Bolt L=300mm - 1 No. (on other leaf)
e) Lever Handle
7.12.51 Door (Type-9C) D-J-3F-06 (Location : Landing store room), sigle leaf, size 750mm x 2100mm, with 35mm thick sand stone cladding on outer face, SS hardware of approved make Nos 1.00 0
a) 5 Knl, Ball bearing offset heavy duty hinges (suitable to take additional load of sand stone) size 100 x 75 x 3mm, SSS - 3 Nos.
a) 5 Knl, Ball bearing hinges size 100 x 75 x 3mm, SSS - 3 Nos.
b) Cylindrical lock
c) Surface door closer, Medium duty EN 2-4 with std arm, Silver finish - 1 No. (on one leaf)
d) Concealed Flush Bolt L=300mm - 1 No. (on other leaf)
e) Lever Handle
7.12.52 Door (Type-7B) D-J-4F-10 (Location : Café kitchen), size 1475mm x 2400mm, with double equal leaves door shutters (737.5mm + 737.5mm) with fire rated SS hardware of approved make Nos 1.00 0
a) 5 Knl, Ball bearing hinges size 100 x 75 x 3mm, SSS - 6 Nos.
b) Cylindrical lock
c) Pull/push handel
d) Concealed door closer, Medium duty EN 2-4 with std arm, Silver finish - 1 No.
e) Door stopper
7.12.53 Door (Type-11) D-J-4F-12 (Location : Kitchen ramp), Double leaf, size 1500mm x 2100mm, with double unequal leaves door shutter (900mm + 600mm) with SS hardware of approved make Nos 1.00 0
a) 5 Knl, Ball bearing hinges size 100 x 75 x 3mm, SSS - 6 Nos.
b) Cylindrical lock
c) Pull/push handel
d) Surface door clouser - 1 No.
e) Door stopper
f) Floor spring
7.12.54 Door (Type-7) D-N-G-01, D-FS-G-01 (Location : Security cabin) size 900mm x 2250mm, with signle leaf door shutters with fire rated SS hardware of approved make Nos 2.00 0
a) 5 Knl, Ball bearing hinges size 100 x 75 x 3mm, SSS - 3 Nos.
b) Cylindrical lock with knobs and key opening
c) Surface door closer, Medium duty EN 2-4 with std arm, Silver finish - 1 No. (on one leaf)
d) Concealed Flush Bolt L=300mm - 1 No. (on other leaf)
e) Lever Handle
7.13 Insulated Hollow metal fire rated doors
Providing and fixing of medium duty hollow metal fire rated doors as per IS 3614: 2021, for 120min integrity & 30min. insulation. Pressed galvanized steel confirming to IS 277 with the following specification. Recommended fire door shall be tested to IS 17518 (Part 1) : 2022 / ISO 3008-1: 2019 from CBRI lab and manufactured in ISO 9001: 2015 certfied company for quality management. ISI labled fire door shall be with fire rated hardware and vision panel all as a complete assembly and shall not be more than 58kg/Sqmt in weight. Proper label confirming the type of door and the hourly rating is mandatory. NOTE- Doors tested in latched condition cannot be replaced with unlatched doors (Deadbolt & Handle) in actual site condition. Need independent testing for both latched and unlatched doors. Ref Page No-8 & 10, Sec: 7.2.9 & 7.3.6 of Builder’s Hardware IS3614:2021.
Door frame shall be step rebate grooved profile of size 125 x 75mm made out of 1.20mm (18gauge) minimum thick galvanized steel sheet. Frames shall be mitered and field assembled with self tabs. Frames to have inbuild grooved sealing system for taking fire rated EPDM seals. All provision should be mortised, drilled and tapped for receiving appropriate hardware. Frames should be provided with back plate bracket and anchor fasteners for installation on a finished plastered masonry wall opening. Frames shall be filled with fire rated puff.
Door leaf shall be 60mm thick fully flush double skin step design door, insulated with or without vision lite. Door leaf shall be manufactured from 1.2mm (18guage) minimum thick galvanised steel sheet. The internal construction of the door should be rigid reinforcement pads for receiving appropriate hardware. The infill material shall be high density mineral wool with a density not less than 120kg/m3 as an insulation material. Intumescent seals 15 x 1.5mm to be provided. All ISI labelled doors shall be factory prepped for receiving appropriate hardware and provided with necessary reinforcement for hinges, locks, and door closers. The edges should be interlocked with a bending radius of 1.4mm. For pair of doors integrated astragals has to be provided on the meeting stile for both active and inactive leaf. Vision lite wherever applicable shall be maximum 200 x 300mm (or max 0.06sq.mt) with clear borosilicate fire rated glass of 6mm. Glass shall be fixed with suitable gasket and with clip-on arrangement.
Door and frames shall be finished Pure Polyester Powder coated (15 years guarantee) and shall have passed minimum 500 hours of salt spray test.
Rate shall include supply and installation of frame,shutter as a complete assembly including all hardware, smoke seals & glass with tape.
7.13.1 Door D-A-L-01 (Location Server Room) & D-B-L-12 (Location : UPS bank) & D-B-M-11 (Location : BMS room) & D-B-M-12 (Location : Electrical room) & D-D-L-01 (Location : IT work room), size 1200mm x 2100mm, with double unequal leaves door shutters (900mm + 300mm) with fire rated SS hardware of approved make Nos 5.00 0
a) 5 Knl, Ball bearing hinges size 100 x 75 x 3mm, SSS - 6 Nos.
b) Narrow profile Mortise Dead lock, 35 BS/8mm, SSS finish with cyl, escutheion suitable for double leaf door
c) Surface door closer, Medium duty EN 2-4 with std arm, Silver finish - 1 No. (on bigger leaf)
d) Concealed Flush Bolt L=300mm - 1 No. (on smaller leaf)
e) Lever Handle with roses & Escutcheons
7.13.2 Door (Type-9) D-A-G-04, D-G-G-01 (Location: AHU - Auditorium, AHU-GF Gallery), size 1800mm x 2400mm, with double unequal leaves door shutters (1200mm + 600mm) with 35mm thick sand stone fire rated SS hardware of approved make Nos 2.00 0
a) 5 Knl, Ball bearing offset hinges heavy duty (suitable to take additional load of sand stone) size 100 x 75 x 3mm, SSS - 6 Nos.
b) Narrow profile Mortise Dead lock, 35 BS/8mm, SSS finish with cyl, escutheion suitable for double leaf door
c) Surface door closer, Medium duty EN 2-4 with std arm, Silver finish - 1 No. (on bigger leaf)
d) Concealed Flush Bolt L=300mm - 1 No. (on smaller leaf)
e) Lever Handle with roses & Escutcheons
7.13.3 Door D-A-G-09 (Location: Auditorium-BOH) & D-G-L-02 (Location : Fire exit lobby), size 1500mm x 2400mm, with double equal leaf door shutters (750mm + 750mm), with vision window of size 300mm x 300mm with 6mm thick fire rated glass (#9), with fire rated SS hardware of approved make Nos 2.00 0
a) 5 Knl, Ball bearing offset hinges size 100 x 75 x 3mm, SSS - 6 Nos.
b) Fire rated Single point surface panic latch, as per EN1125, Silver finish
c) Concealed door clouser , Medium duty EN 2-4 with std arm, Silver finish - 1 No. (on bigger leaf)
d) Concealed Flush Bolt L=300mm - 1 No. (on other leaf)
7.13.4 Door (Type-7B) D-B-M-13, D-G-L-03, D-G-L-14 (Location : AHU Mezz, LGF, AHU Tunnel), size 1500mm x 2400mm, with double equal leaf door shutters (750mm + 750mm), with fire rated SS hardware of approved make Nos 3.00 0
a) 5 Knl, Ball bearing offset hinges size 100 x 75 x 3mm, SSS - 6 Nos.
b) Cylindrical lock with knobs, push button inside, emergency opening outside
c) Surface door closer, Medium duty EN 2-4 with std arm, Silver finish - 1 No. (on one leaf)
d) Concealed Flush Bolt L=300mm - 1 No. (on other leaf)
e) Lever Handle with roses & Escutcheons
7.13.5 Door (Type-11) D-A-G-14, D-G-L-11, D-G-G-10, D-G-1F-05, D-J-L-06, D-J-G-03, D-J-G-11, D-J-1F-01, D-J-1F-12, D-J-2F-02, D-J-2F-07, D-J-3F-05, D-J-4F-03, D-J-4F-09 (Location: Fire Escape Staircase) & Door D-A-1F-03, D-B-1F-03, D-C-1F-03 (Location: Fire Escape Staircase) & D-B-G-09 (Location : Lobby-Fire door) & D-G-L-04 (Location : Utsah Gal-Fire exit), D-G-L-10 (Location : Fire sepration door) & D-J-L-07, D-J-1F-02 (Location : Siddhi Gal-Fire exit) & D-J-2F-01, D-J-3F-09 (Location : Ramp fire exit), size 1500mm x 2400mm, with double unequal leaves door shutters (900mm + 600mm) with, with vision window of size 300mm x 300mm with 6mm thick fire rated glass (#9), fire rated SS hardware of approved make Nos 24.00 0
a) 5 Knl, Ball bearing offset hinges size 100 x 75 x 3mm, SSS - 6 Nos.
b) Fire rated Single point surface panic latch, as per EN1125, Silver finish
c) Concealed door closer, Medium duty EN 2-4 with std arm, Silver finish - 1 No. (on bigger leaf)
d) Concealed Flush Bolt L=300mm - 1 No. (on one leaf)
7.13.6 Door (Type-9) D-A-1F-01 (Location: AHU - GAURAV GALLERY), size 1800mm x 1800mm, with double unequal leaves door shutters (1200mm + 600mm) with 35mm thick sand stone fire rated SS hardware of approved make Nos 1.00 0
a) 5 Knl, Ball bearing offset hinges heavy duty (suitable to take additional load of sand stone) size 100 x 75 x 3mm, SSS - 6 Nos.
b) Narrow profile Mortise Dead lock, 35 BS/8mm, SSS finish with cyl, escutheion suitable for double leaf door
c) Surface door closer, Medium duty EN 2-4 with std arm, Silver finish - 1 No. (on bigger leaf)
d) Concealed Flush Bolt L=300mm - 1 No. (on smaller leaf)
e) Concealed handle- 1 No.
f) Brush bottom seal
7.13.7 Door (Type-11) D-A-2F-01, D-B-L-03, D-B-M-03, D-B-M-04, D-B-G-08, D-C-G-05, D-F-L-01, D-F-L-02, D-J-B-02, D-J-L01, D-J-3F-01, D-J-3F-03 (Location: Fire Escape Staircase, Fire Exit), size 1500mm x 2100mm, with double unequal leaves door shutters (900mm + 600mm) with, with vision window of size 300mm x 300mm with with 6mm thick fire rated glass (#9), fire rated SS hardware of approved make Nos 12.00 0
a) 5 Knl, Ball bearing offset hinges size 100 x 75 x 3mm, SSS - 6 Nos.
b) Fire rated Single point surface panic latch, as per EN1125, Silver finish
c) Concealed door closer, Medium duty EN 2-4 with std arm, Silver finish - 1 No. (on bigger leaf)
d) Concealed Flush Bolt L=300mm - 1 No. (on one leaf)
7.13.8 Door (Type-7A) D-B-L-02, D-C-L-03, D-C-L-04, D-C-L-05 , D-C-L-06, D-C-L-07, D-C-L-08, D-D-L-02, 03, 04, 05, 06, 07, 08 (Location: Chiller room, Moving tool storage, Crate storage, Shipping receiving, Transit store, Crating/Uncrating, Plinth & Panel), size 2700mm x 3000mm, with double unequal leaves door shutters (1200mm + 1500mm) with fire rated SS hardware of approved make Nos 14.00 0
a) 5 Knl, Ball bearing offset hinges heavy duty size 100 x 75 x 3mm, SSS - 6 Nos.
b) Narrow profile Mortise Dead lock, 35 BS/8mm, SSS finish with cyl, escutheion suitable for double leaf door
c) Surface door closer, Medium duty EN 2-4 with std arm, Silver finish - 1 No. (on bigger leaf)
d) Concealed Flush Bolt L=300mm - 1 No. (on smaller leaf)
e) Lever Handle with roses & Escutcheons
7.13.9 Door (Type-7A) D-B-L-05 (Location: Quartine room, access door), size 2700mm x 3000mm, with double unequal leaves door shutters (1200mm + 1500mm) with fire rated SS hardware of approved make Nos 1.00 0
a) 5 Knl, Ball bearing offset hinges heavy duty size 150 x 100 x 3mm, SSS - 6 Nos.
b) Provision for Access control
c) Concealed door closer, Medium duty EN 2-4 with std arm, Silver finish - 1 No. (on bigger leaf)
d) Concealed Flush Bolt L=300mm - 1 No. (on smaller leaf)
e) Lever Handle with roses & Escutcheons
7.13.10 Door (Type-7B) D-B-1F-01, D-C-1F-02, D-F-1F-01, D-G-L-15, D-J-L-03, D-J-L-19, D-J-G-05, D-J-M-01, D-J-3F-04, D-J-3F-07, D-J-3F-10 (Location: AHU-Gaurav Gallery, AHU Restaurant, Pump room, AHU-Ent lobby, AHU, AHU curved ramp, AHU above floor), size 1500mm x 2100mm, with double equal leaves door shutters (750mm + 750mm) with fire rated SS hardware of approved make Nos 11.00 0
a) 5 Knl, Ball bearing offset hinges heavy duty size 100 x 75 x 3mm, SSS - 6 Nos.
b) Narrow profile Mortise Dead lock, 35 BS/8mm, SSS finish with cyl, escutheion suitable for double leaf door
c) Surface door closer, Medium duty EN 2-4 with std arm, Silver finish - 1 No. (on bigger leaf)
d) Concealed Flush Bolt L=300mm - 1 No. (on smaller leaf)
e) Lever Handle with roses & Escutcheons
7.13.11 Door (Type-11B) D-B-1F-07, D-J-L-22 (Location: Fire Escape Staircase), size 1200mm x 2400mm, with single leaves door shutters with, with vision window of size 300mm x 300mm with with 6mm thick fire rated glass (#9), fire rated SS hardware of approved make Nos 2.00 0
a) 5 Knl, Ball bearing offset hinges size 100 x 75 x 3mm, SSS - 3 Nos.
b) Fire rated Single point surface panic latch, as per EN1125, Silver finish
c) Concealed door closer, Medium duty EN 2-4 with std arm, Silver finish - 1 No. (on bigger leaf)
d) Concealed Flush Bolt L=300mm - 1 No. (on one leaf)
7.13.12 Door (Type-11B) D-B-2F-08 (Location: Fire Escape Staircase), size 1200mm x 2100mm, with single leaf door shutters , with vision window of size 300mm x 300mm with with 6mm thick fire rated glass (#9), fire rated SS hardware of approved make Nos 1.00 0
a) 5 Knl, Ball bearing offset hinges size 100 x 75 x 3mm, SSS - 3 Nos.
b) Fire rated Single point surface panic latch, as per EN1125, Silver finish
c) Surface door closer, Medium duty EN 2-4 with std arm, Silver finish - 1 No. (on one leaf)
d) Concealed Flush Bolt L=300mm - 1 No. (on one leaf)
7.13.13 Door (Type-7A) D-C-L-02 (Location : Metering Kiosk), sigle leaf, size 2100mm x 1500mm, with double unequal leaves door shutter (900mm + 600mm) with SS hardware of approved make Nos 1.00 0
a) 5 Knl, Ball bearing hinges size 100 x 75 x 3mm, SSS - 6 Nos.
b) Cylindrical lock with knobs, push button inside, emergency opening outside
c) Surface door closer
d) Door stopper
7.13.14 Door (Type-11A) D-F-G-11, D-F-1F-06, D-G-L-12 (Location: Fire Escape Staircase, Tunnel Fire Exit), size 1800mm x 2400mm, with double equal leaves door shutters (900mm + 900mm) with, with vision window of size 300mm x 300mm with 6mm thick fire rated glass (#9), fire rated SS hardware of approved make Nos 3.00 0
a) 5 Knl, Ball bearing offset hinges size 100 x 75 x 3mm, SSS - 6 Nos.
b) Fire rated Single point surface panic latch, as per EN1125, Silver finish
c) Concealed door closer, Medium duty EN 2-4 with std arm, Silver finish - 1 No. (on bigger leaf)
d) Concealed Flush Bolt L=300mm - 1 No. (on one leaf)
7.13.15 Door (Type-11) D-F-2F-01 (Location: Fire Shaft) , overall size 1500mm x 2100mm, with double unequal leaves door shutters (900mm + 600mm) with, with vision window of size 300mm x 300mm with 6mm thick fire rated glass (#9), fire rated SS hardware of approved make Nos 5.00 0
a) 5 Knl, Ball bearing offset hinges size 100 x 75 x 3mm, SSS - 6 Nos.
b) Fire rated Single point surface panic latch, as per EN1125, Silver finish
c) Concealed door closer, Medium duty EN 2-4 with std arm, Silver finish - 1 No. (on bigger leaf)
d) Concealed Flush Bolt L=300mm - 1 No. (on one leaf)
7.13.16 Door (Type-7B) D-G-1F-03 (Location: AHU), size 1800mm x 2400mm, with double equal leaves door shutters (900mm + 900mm) with fire rated SS hardware of approved make Nos 1.00 0
a) 5 Knl, Ball bearing hinges size 100 x 75 x 3mm, SSS - 6 Nos.
b) Cylindrical lock with knobs, push button inside, emergency opening outside
c) Concealed door closer, Medium duty EN 2-4 with std arm, Silver finish - 1 No. (on bigger leaf)
d) Concealed Flush Bolt L=300mm - 1 No. (on smaller leaf)
e) Lever Handle with roses & Escutcheons
7.13.17 Door (Type-7B) D-J-B-01, D-J-B-07 (Location: Pump room), size 2100mm x 2400mm, with double equal leaves door shutters (1050mm + 1050mm) with fire rated SS hardware of approved make Nos 2.00 0
a) 5 Knl, Butt hinges size 100 x 75 x 3mm, SSS - 6 Nos.
b) Cylindrical lock with knobs, push button inside, emergency opening outside
c) Surface door closer, Medium duty EN 2-4 with std arm, Silver finish - 1 No. (on bigger leaf)
d) Concealed Flush Bolt L=300mm - 1 No. (on smaller leaf)
e) Lever Handle with roses & Escutcheons
7.13.18 Door (Type-7A) D-J-B-03 (Location: Staircase), size 1200mm x 2100mm, with double eunqual leaves door shutters (900mm + 300mm) with fire rated SS hardware of approved make Nos 1.00 0
a) 5 Knl, Ball bearing hinges size 100 x 75 x 3mm, SSS - 6 Nos.
b) Cylindrical lock with knobs, push button inside, emergency opening outside
c) Surface door closer, Medium duty EN 2-4 with std arm, Silver finish - 1 No. (on bigger leaf)
d) Concealed Flush Bolt L=300mm - 1 No. (on smaller leaf)
e) Lever Handle with roses & Escutcheons
7.13.19 Door (Type-7A) D-J-B-04, D-J-B-05, D-J-B-06 (Location: LT panel area, DG area), size 1500mm x 2100mm, with double unequal leaves door shutters (900mm + 600mm) with fire rated SS hardware of approved make Nos 3.00 0
a) 5 Knl, Ball bearing hinges size 100 x 75 x 3mm, SSS - 6 Nos.
b) Cylindrical lock with knobs, push button inside, emergency opening outside
c) Surface door closer, Medium duty EN 2-4 with std arm, Silver finish - 1 No. (on bigger leaf)
d) Concealed Flush Bolt L=300mm - 1 No. (on smaller leaf)
e) Lever Handle with roses & Escutcheons
7.13.20 Door (Type-7) D-J-L-09 (Location: Lift lobby), size 1250mm x 3600mm, with single door shutters with 12mm thick Plywood backing on one side of the door finish with approved 4mm thick veneer finish with fire rated SS hardware of approved make Nos 1.00 0
a) 5 Knl, Ball bearing offset hinges size 100 x 75 x 3mm, SSS - 3 Nos.
b) Pull/Push handle
c) Concealed door closer, Medium duty EN 2-4 with std arm, Silver finish - 1 No. (on bigger leaf)
d) Concealed Flush Bolt L=300mm - 1 No. (on one leaf)
7.13.21 Door (Type-7) D-J-L-11 (Location: Lift lobby), size 1200mm x 3600mm, with single equal leaves door shutters , with fire rated SS hardware of approved make Nos 1.00 0
a) 5 Knl, Ball bearing offset hinges size 100 x 75 x 3mm, SSS - 3 Nos.
b) Concealed handle
c) Concealed door closer, Medium duty EN 2-4 with std arm, Silver finish - 1 No. (on bigger leaf)
d) Concealed Flush Bolt L=300mm - 1 No. (on one leaf)
7.13.22 Door (Type-7A) D-J-3F-08 (Location: Lift lobby), size 1500mm x 2400mm, with double eunqual leaves door shutters (900mm + 600mm) with fire rated SS hardware of approved make Nos 1.00 0
a) 5 Knl, Ball bearing hinges size 100 x 75 x 3mm, SSS - 6 Nos.
b) Cylindrical lock with knobs, push button inside, emergency opening outside
c) Concealed door closer, Medium duty EN 2-4 with std arm, Silver finish - 1 No. (on bigger leaf)
d) Concealed Flush Bolt L=300mm - 1 No. (on smaller leaf)
e) Lever Handle with roses & Escutcheons
7.13.23 Door (Type-7) D-J-3F-11 (Location: Service passage), size 900mm x 2100mm, with single leaves door shutters with fire rated SS hardware of approved make Nos 1.00 0
a) 5 Knl, Ball bearing hinges size 100 x 75 x 3mm, SSS - 3 Nos.
b) Cylindrical lock
c) Surface door closer, Medium duty EN 2-4 with std arm, Silver finish - 1 No. (on bigger leaf)
e) Lever Handle with roses & Escutcheons
7.16 Un-Insulated Hollow metal fire doors
Providing and fixing of medium duty hollow metal fire rated doors as per IS 3614: 2021, for 120min integrity only.Pressed galvanized steel confirming to IS 277 with the following specification. Recommended fire door shall be tested to IS 17518 (Part 1) : 2022 / ISO 3008-1: 2019 from CBRI lab and manufactured in ISO 9001: 2015 certfied company for quality management. ISI labled fire door shall be with fire rated hardware and vision panel all as a complete assembly and shall not be more than 34kg/Sqmt in weight. Proper label confirming the type of door and the hourly rating is mandatory. NOTE- Doors tested in latched condition cannot be replaced with unlatched doors (Deadbolt & Handle) in actual site condition. Need independent testing for both latched and unlatched doors. Ref Page No-8 & 10, Sec: 7.2.9 & 7.3.6 of Builder’s Hardware IS3614:2021.
Door frame shall be single rebate grooved profile of size 125 x 55mm made out of 1.20mm (18gauge) minimum thick galvanized steel sheet. Frames shall be mitered and field assembled with self tabs. Frames to have inbuild grooved sealing system for taking fire rated EPDM seals. All provision should be mortised, drilled and tapped for receiving appropriate hardware. Frames should be provided with back plate bracket and anchor fasteners for installation on a finished plastered masonry wall opening. Frames shall be filled with fire rated puff (paid extra).
Door leaf shall be 46mm thick fully flush double skin door, sandwiched panel un-insulated with or without vision lite. Door leaf shall be manufactured from 1.2mm (18guage) minimum thick galvanised steel sheet. The internal construction of the door should be rigid reinforcement pads for receiving appropriate hardware. The infill material shall be honeycomb core. All doors shall be factory prepped for receiving appropriate hardware and provided with necessary reinforcement for hinges, locks, and door closers. The edges should be interlocked with a bending radius of 1.4mm. For pair of doors integrated astragals has to be provided on the meeting stile for both active and inactive leaf. Vision lite wherever applicable shall be maximum 150 x 750mm (or max 0.12sq.mt) with clear borosilicate fire rated glass of 6mm. Glass shall be fixed with suitable gasket and with clip-on arrangement.
Door and frames shall be finished Pure Polyester Powder coated and shall have passed minimum 500 hours of salt sprey test.
Rate shall include supply and installation of frame,shutter as a complete assembly including all hardware, smoke seals & glass with tape.
7.16.1 Door (Type-DS3) DS-A-L-02, DS-G-G-01, DS-G-1F-01 (Location Fire Shaft), size 900mm x 1500mm, with double unequal leaves door shutters (600mm + 300mm) with fire rated SS hardware of approved make Nos 3.00 0
a) 5 Knl, Butt hinges size 100 x 75 x 3mm, SSS - 6 Nos.
b) Allen key Dead lock, suitable for double leaf
7.16.2 Door (Type-11) D-A-M-01, D-J-L-12, D-J-L-13 (Location Mezzanine Fire Exit, Fire Exit), size 1500mm x 2100mm, with double unequal leaves door shutters (900mm + 600mm) with vision window of size 300mm x 300mm with 6mm thick fire rated glass (#9), fire rated SS hardware of approved make Nos 3.00 0
a) 5 Knl, Ball bearing hinges size 100 x 75 x 3mm, SSS - 6 Nos.
b) Fire rated Single point surface panic latch, as per EN1125, Silver finish
c) Surface door closer, Medium duty EN 2-4 with std arm, Silver finish - 1 No. (on bigger leaf)
d) Concealed Flush Bolt L=300mm - 1 No. (on smaller leaf)
7.16.3 Door (Type-11) D-A-G-08 (Location Auditorium Fire Exit), size 1500mm x 2100mm, with double unequal leaves door shutters (900mm + 600mm) with vision window of size 300mm x 300mm with 6mm thick fire rated glass (#9), fire rated SS hardware of approved make Nos 1.00 0
a) 5 Knl, Ball bearing hinges size 100 x 75 x 3mm, SSS - 6 Nos.
b) Fire rated Single point surface panic latch, as per EN1125, Silver finish
c) Surface door closer, Medium duty EN 2-4 with std arm, Silver finish - 1 No. (on bigger leaf)
d) Concealed Flush Bolt L=300mm - 1 No. (on smaller leaf)
7.16.4 Door (Type-DS3) DS-A-G-01, DS-F-G-05, DS-F-1F-05, DS-J-G-06 , DS-J-1F-06, DS-J-2F-01, DS-J-2F-02 (Location FF Shaft), size 900mm x 1800mm, with double unequal leaves door shutters (600mm + 300mm) with fire rated SS hardware of approved make Nos 7.00 0
a) 5 Knl, Ball bearing hinges size 100 x 75 x 3mm, SSS - 6 Nos.
b) Allen key Dead lock, suitable for double leaf
c) Concealed handles
7.16.5 Door (Type-DS3) DS-A-1F-01 (Location: Fire Shaft), size 1200mm x 1800mm, with double unequal leaves door shutters (600mm + 600mm) with fire rated SS hardware of approved make Nos 1.00 0
a) 5 Knl, Ball bearing hinges size 100 x 75 x 3mm, SSS - 6 Nos.
b) Allen key Dead lock, suitable for double leaf
c) Concealed handle from outside
7.16.6 Door (Type-DS) DS-A-1F-02 (Location: Fire Shaft), size 1200mm x 1800mm, with double leaf door shutters with fire rated SS hardware of approved make Nos 2.00 0
a) 5 Knl, Ball bearing hinges size 100 x 75 x 3mm, SSS - 6 Nos.
b) Allen key Dead lock, suitable for double leaf
c) Concealed handle from outside
7.16.7 Door (DS-1) DS-A-2F-01 (Location Fire Shaft), size 900mm x 2100mm, with single leaf door shutter with fire rated SS hardware of approved make Nos 1.00 0
a) 5 Knl, Ball bearing hinges size 100 x 75 x 3mm, SSS - 3 Nos.
b) Allen key Dead lock, suitable for double leaf
7.16.8 Door (Type-DS1) DS-B-M-01, DS-B-G-03, DS-B-1F-02, DS-C-L-01, DS-C-1F-01, DS-F-L-02, DS-F-L-03, DS-G-L-01, DS-G-L-03, DS-G-1F-02, DS-J-G-08, DS-J-3F-02 (Location : FF shaft, Plumbing shaft, HVAC shaft, FF Hose shaft), sigle leaf, size 900mm x 1500mm, with SS hardware of approved make Nos 12.00 0
a) 5 Knl, Ball bearing hinges size 100 x 75 x 3mm, SSS - 3 Nos.
b) Allen key Dead lock
c) Concealed handle
7.16.9 Door (DS-2) DS-B-G-04 (Location : FF shaft), double equal leaf, size 1200mm x 1800mm, with SS hardware of approved make Nos 1.00 0
a) 5 Knl, Ball bearing hinges size 100 x 75 x 3mm, SSS - 3 Nos.
b) Allen key Dead lock, suitable for double leaf
c) Concealed handle
7.16.10 Door (Type-DS-1) DS-B-1F-04 , DS-F-L-01, DS-F-G-01, DS-F-G-03, DS-F-1F-03, DS-G-G-02. DS-J-1F-08 (Location : FF shaft, Electrical shaft, FF House shaft), single equal leaf, size 900mm x 1800mm, with SS hardware of approved make Nos 7.00 0
a) 5 Knl, Ball bearing hinges size 100 x 75 x 3mm, SSS - 3 Nos.
b) Allen key Dead lock
c) Concealed handle
7.16.11 Door (Type-DS2) DS-B-2F-01, DS-J-L-01, DS-J-L-02, DS-J-1F-01, DS-J-4F-01, DS-J-4F-02 (Location FF Shaft), size 900mm x 1800mm, with double equal leaves door shutters (450mm + 450mm) with fire rated SS hardware of approved make Nos 6.00 0
a) 5 Knl, Ball bearing hinges size 100 x 75 x 3mm, SSS - 6 Nos.
b) Allen key Dead lock, suitable for double leaf
7.16.12 Door (Type-11) D-C-L-09 (Location: Fire Escape Staircase), size 1800mm x 2100mm, with double unequal leaves door shutters (1200mm + 600mm) with, with vision window of size 300mm x 300mm with 6mm thick fire rated glass (#9), fire rated SS hardware of approved make Nos 4.00 0
a) 5 Knl, Ball bearing offset hinges size 100 x 75 x 3mm, SSS - 6 Nos.
b) Fire rated Single point surface panic latch, as per EN1125, Silver finish
c) Surface door closer, Medium duty EN 2-4 with std arm, Silver finish - 1 No. (on bigger leaf)
d) Concealed Flush Bolt L=300mm - 1 No. (on one leaf)
7.16.13 Door (Type-7) D-C-L-10, D-C-L-11 (Location : Loading bay Steps, Ramp), size 1200mm x 2100mm, with double unequal leaves door shutters (900mm + 300mm) with SS hardware of approved make Nos 2.00 0
a) 5 Knl, Ball bearing hinges size 100 x 75 x 3mm, SSS - 6 Nos.
b) Cylindrical lock with knobs and key opening
c) Surface door closer, Medium duty EN 2-4 with std arm, Silver finish - 1 No. (on bigger leaf)
d) Concealed Flush Bolt L=300mm - 1 No. (on smaller leaf)
7.16.14 Door (Type-7A) D-E-L-01 (Location : AV store), size 200mm x 2100mm, with double unequal leaves door shutters (900mm + 300mm) with SS hardware of approved make Nos 1.00 0
a) 5 Knl, Ball bearing hinges size 100 x 75 x 3mm, SSS - 6 Nos.
b) Cylindrical lock with knobs and key opening
c) Surface door closer, Medium duty EN 2-4 with std arm, Silver finish - 1 No. (on bigger leaf)
d) Concealed Flush Bolt L=300mm - 1 No. (on smaller leaf)
7.16.15 Door (Type-7A) DS-C-1F-02, DS-C-1F-03 (Location FF Shaft, HVAC shaft), overall size 900mm x 1500mm, with double unequal leaves door shutters (600mm + 300mm) with fire rated SS hardware of approved make Nos 2.00 0
a) 5 Knl, Ball bearing hinges size 100 x 75 x 3mm, SSS - 6 Nos.
b) Allen key Dead lock, suitable for double leaf
c) Concealed handle
7.16.16 Door (Type-7) DS-C-G-04 (Location: FF shaft), size 1200mm x 1800mm, with double equal leaves door shutters (600mm + 600mm) with 35mm thick sand stone fire rated SS hardware of approved make Nos 1.00 0
a) 5 Knl, Ball bearing offset hinges heavy duty (suitable to take additional load of sand stone) size 100 x 75 x 3mm, SSS - 6 Nos.
b) Allen key Dead lock, suitable for double leaf
c) Concealed handle
7.16.17 Door (Type-7B) D-E-1F-01, (Location: AHU-1F), size 1500mm x 2100mm, with double equal leaves door shutters (750mm + 750mm) with fire rated SS hardware of approved make Nos 1.00 0
a) 5 Knl, Ball bearing offset hinges heavy duty size 100 x 75 x 3mm, SSS - 6 Nos.
b) Narrow profile Mortise Dead lock, 35 BS/8mm, SSS finish with cyl, escutheion suitable for double leaf door
c) Surface door closer, Medium duty EN 2-4 with std arm, Silver finish - 1 No. (on bigger leaf)
d) Concealed Flush Bolt L=300mm - 1 No. (on smaller leaf)
e) Lever Handle with roses & Escutcheons
7.16.18 Door (Type-DS1) DS-F-G-02, DS-F-1F-02, DS-J-G-07 (Location: Plumbing Shaft), size 600mm x 1800mm, with single leaf door shutters with fire rated SS hardware of approved make Nos 3.00 0
a) 5 Knl, Ball bearing hinges size 100 x 75 x 3mm, SSS - 6 Nos.
b) Allen key Dead lock
c) Concealed handle from outside
7.16.19 Door (Type-DS1) DS-G-L-04, DS-G-G-06, DS-G-1F-03, DS-J-L-06, DS-J-L-07, DS-J-L-08, DS-J-G-02, DS-J-G-03, DS-J-G-04, DS-J-1F-02, DS-J-1F-03, DS-J-1F-04 (Location: HVAC Shaft, Electrical shaft, DG shaft), size 600mm x 1500mm, with single leaf door shutters with fire rated SS hardware of approved make Nos 12.00 0
a) 5 Knl, Ball bearing hinges size 100 x 75 x 3mm, SSS - 6 Nos.
b) Allen key Dead lock
c) Concealed handle from outside
7.16.20 Door (Type-DS-1A) DS-G-G-04 (Location PHE Shaft), sigle leaf, size 600mm x 1800mm, with 35mm thick sand stone cladding on outer face, SS hardware of approved make Nos 1.00 0
a) 5 Knl, Ball bearing offset heavy duty hinges (suitable to take additional load of sand stone) size 100 x 75 x 3mm, SSS - 3 Nos.
b) Allen key Dead lock
c) Concealed handle
7.16.21 Door (Type-DS1) DS-G-G-05 (Location : FF + HVAC Shaft), sigle leaf, size 900mm x 1800mm, with 35mm thick sand stone cladding on outer face, SS hardware of approved make Nos 1.00 0
a) 5 Knl, Ball bearing offset heavy duty hinges (suitable to take additional load of sand stone) size 100 x 75 x 3mm, SSS - 3 Nos.
b) Allen key Dead lock
c) Concealed handle
7.16.22 Door (Type-10) D-G-1F-07 (Location : Landscape service, single equal leaf, size 900mm x 1800mm, with SS hardware of approved make Nos 1.00 0
a) 5 Knl, Ball bearing hinges size 100 x 75 x 3mm, SSS - 3 Nos.
b) Cylindrical lock with knobs and key opening
c) Surface door closer, Medium duty EN 2-4 with std arm, Silver finish - 1 No. (on one leaf)
d) Concealed Flush Bolt L=300mm - 1 No. (on other leaf)
e) Lever Handle
7.16.23 Door (Type-DS1) DS-J-L-05 (Location: FF Shaft), size 900mm x 2400mm, with single leaf door shutters with fire rated SS hardware of approved make Nos 2.00 0
a) 5 Knl, Ball bearing hinges size 100 x 75 x 3mm, SSS - 3 Nos.
b) Allen key Dead lock
c) Concealed handle from outside
7.16.24 Door (Type-6) DS-J-2F-04 (Location: FF Shaft), size 900mm x 2400mm, with single leaf door shutters with 12mm thick Plywood backing on one side of the door finish with approved 4mm thick veneer finish with fire rated SS hardware of approved make Nos 2.00 0
a) 5 Knl, Ball bearing hinges size 100 x 75 x 3mm, SSS - 3 Nos.
b) Allen key Dead lock
c) Concealed handle from outside
7.16.25 Door (Type-DS1) DS-J-1F-10 (Location : FF Shaft), sigle leaf, size 900mm x 2400mm, with 12mm thick Plywood backing on one side of the door finish with approved 4mm thick veneer finish with SS hardware of approved make Nos 1.00 0
a) 5 Knl, Ball bearing hinges size 100 x 75 x 3mm, SSS - 3 Nos.
b) Allen key Dead lock
c) Concealed handle from outside
7.16.26 Door (Type-DS2) DS-J-3F-01 (Location Fire Shaft), size 900mm x 1500mm, with double equal leaves door shutters (450mm + 450mm) with fire rated SS hardware of approved make Nos 1.00 0
a) 5 Knl, Ball bearing hinges size 100 x 75 x 3mm, SSS - 6 Nos.
b) Allen key Dead lock, suitable for double leaf
7.18 Designing, providing, fixing electrically operated galvanized rolling shutters made from nominal 75mm wide interlocking laths. Sections of minimum 18 gauge. Shutters are divided for opening as per detailed. Further to include endlocks, windlocks and angles at bottom of curtain, curtain guides, hood etc. all of G.I. and roller shaft, counterbalance balance mechanism, brackets of steel all anti - corrosion treated. Mechanism to operate with electrical motors at rate of approximately 300mm/sec. Further to have arrangement for manual operating by crane / chain in case of power failure.
7.18.1 GI Shutters non-perforated fire rated RS-A-1F-01 size 2500mm x 5900mm (motor operated) (Location : RS Gaurav Gal) Nos 1.00 0
7.18.2 GI Shutters non-perforated fire rated RS-B-1F-01 size 3100mm x 5900mm (motor operated) (Location : Fire COMPRT RS) Nos 1.00 0
7.18.3 GI Shutters 80% perforated fire rated RS-C-L-01 size 1800mm x 2100mm (motor operated) (Location : Waste Management) Nos 1.00 0
7.18.4 GI Shutters Single skin non-insulated fire rated RS-C-L-02 size 1800mm x 2100mm (motor operated) (Location : Loading bay) Nos 1.00 0
7.18.5 GI Shutters Single skin non-insulated fire rated RS-G-L-01 size 3000mm x 3600mm (motor operated) (Location : Fire CMPRT RS) Nos 1.00 0
7.18.6 GI Shutters 80% perforated RS-J-B-01, RS-J-B-02 size 4000mm x 3250mm (motor operated) (Location : LT panel, DG) Nos 2.00 0
7.18.7 GI Shutters 80% perforated RS-J-B-03, RS-J-B-04 size 4000mm x 5200mm (motor operated) (Location : DG) Nos 2.00 0
7.18.8 GI Shutters Single skin non-insulated fire rated RS-J-L-01 size 4500mm x 4800mm (motor operated) (Location : Fire rated Comparatmentalization) Nos 2.00 0
7.18.9 GI Shutters 80% perforated RS-J-L-02, RS-J-L-03 size 2400mm x 2100mm (motor operated) (Location : Gas bank) Nos 2.00 0
7.18.10 GI Shutters 80% perforated RS-J-L-04, size 3550mm x 2100mm (motor operated) (Location : Gas bank) Nos 1.00 0
7.18.11 GI Shutters Non perforated RS-K-G-01, size 2725mm x 1800mm (motor operated) (Location : RS ticketing counter) Nos 1.00 0
7.18.12 GI Shutters 80% perforated RS-K-G-02,03, size 1400mm x 1800mm (motor operated) (Location : RS clock room) Nos 1.00 0
7.19 Providing, fabricating and fixing in position Thresholds below doors as per A-13 series drawings, schedules in A-13-15 & 16 and as detailed in drawing A-13-20, made out of Stainless steel 304 grade plates, angles as per drawing to the entire satisfaction of the EIC.
7.19.3 Type-3A Rmt 48.45 0
7.19.4 Type-4 with EPDM rubber seal gasket Rmt 54.00 0
7.19.5 Type-4A with EPDM rubber seal gasket Rmt 5.40 0
7.19.7 Type-5A Rmt 4.34 0
7.19.9 Type-6A Rmt 16.20 0
7.20 Supply and installation of approved Titanium Alloy Roofing sheet having 25/430mm sheet profile STANDING SEAM ROOFING SYSTEM IN 0.7mm THICK Zinc. Titanium Alloy comprising of the followings (Drawing no-A12-09 & 15/A14-01) Sqm 2,098.00 0
Top layer – Zinc titanium Alloy standing seam profiled panels 25 /430 (25 mm seam height & 430mm panel width) manufactured from zinc titanium alloy in 0.7mm miniumum thickness having Quartz Plus finish for Roofing application. The material properties shall be as follows: Ultimate tensile strength: minimum 150 N/mm2,0.2% Proof Stress: min 100 N/mm2, Modulus of elasticity: 90,000 N/mm2 Panels shall be fixed to the substructure using Stainless Steel clips fixing & sliding clips of suitable height with spacing as required for the wind loads. The roofing sheets shall be as per EN 988 standards. The zinc roof sheets shall have a protection on its underside consisting of a 60 micron thick composite acrylate-urethane protective coating.
Second Layer: Synthetic Mesh - Anti Abrasive breathable membrane to be laid underneath the Zinc
Third Layer : 1.0 mm thick GI strips to place at distance of 330 to 430 mm for fixing of clips
Fourth Layer 0.47mm TCT Hi-Tensile steel sheets profile with nominal 3 to 4mm deep ribs at pitch of nominal 50 to 55mm centre to centre distance 550 MPa Yield Strength. The decking sheet shall be fixed over the galvanized steel Hat Section using
Fifth Layer : Z GIRT: Sub girt in Z-section 1.6mm thick in galvanised steel fixed to steel purlins through
Sixth Layer : Insulation layer – Rockwool Insulation of overall thickness 100mm with 60Kg/m3 density
Insulation shall be with one side Aluminum foil to act as vapor barrier
Rate also inclusive of supply & fixing of zinc flashing having girth upto 200mm comprising of following layers, i) First Layer - Zinc Titanium Alloy flashing manufactured from zinc titanium alloy in 0.7mm minimum thickness having Quartz plus surface Finish, ii) Second Layer - Synthetic mesh - Anti abrasive breathable membrane laid underneath the zinc flashings, iii) Third Layer - Galvanized Steel continuous stiffener having 0.8mm thickness along the length of flashing for support.
7.21 Supply and installation of A1 fence UNICON sheild 3510 anti climb welded mesh modular fence system in thermoplastic powder coating (colour-antracite grey RAL 7016) with Y-arm and SS 316 concertina coil razor blade tape.the fincing is fixed over the RCC foundations at a regular interval of spacing 2.5 mter c/c. Complete as directed. Vendor to submit shop drawing. Rmt 443.00 0
7.22 Providing and fixing in position 40x40mm and 10 guage GI chainlink with 50x50x6mm GI angle & 15 mm wide 3mm thk GI flat & 50x50x3.6 mm GI bos section for verticle suppoty etc as per detailed drawing including streatching, fixing with necessary holdfast for every verticle supports, hooks, nuts , bolts, washers and applying 1 coat of primer and 2 coats of epoxy paint of approved make, shade & colour etc. complete as directed. Rmt 431.00 0
TOTAL OF STEEL WORK 0
8. ROOFING & CEILING
The rates quoted by the Contractor for items under this head shall be inclusive of the following:
a) Designing and fixing suspension system including edging angles, accessories etc. for reflected false ceiling drawings to be prepared and got approved based on concept Architectural and Services drawings.
b) Finishing with Gypsum wherever specified.
c) Providing and doing arrangement to receive light fittings, fixtures, A.C. grills, diffusers etc.
d) Ceiling to be paid as per area in plan only. Also for circular, elliptical ceilings / lighting troughs shall determine for areas.
f) Cost of ceiling also to include providing grooves at junctions of Gypsum & all other places wherever required as per instructions of PM.
g) Rate to include all cutting and everything else necessary to complete the work
h) Rate shall include all materials including wastages, labour, tools and plants etc. Also including required scaffolding if any.
i) Work at all heights and leads including required staging, scaffolding etc. No extra rate for height shall be paid
j) Cost of ceiling to include cost of lighting troughs, coffers, pattas, verticals, grooves etc complete. Cost also to include Cornices of various profile as shown in drawing, on verticals of lighting troughs also flat verticals.
k) Pressed GI metal sections in combination of GI wire/section hangers are fixed with anchor fasteners to ceiling providing basic hanging and suspension frame work. These are readily available or may be specially fabricated to suit site requirement.Grid shall be adjusted to suit other requirements to approval of the PM.
l) Finished area shall be measured for payment. No deduction will be made for openings/cut outs upto 0.5 sq.m
m) All the additional supports required for grils, light fittings etc. for strengthening shall be included in the quoted rate and no extra shall be paid. The measurement shall be for the surface area.
8.1 Providing and fixing at all height false ceiling including providing and fixing of frame work made of special sections power pressed from M.S. sheet and galvanized in accordance with zinc coating of grade 350 as per IS : 277 and consisting of angle cleats of size 25mm wide x 1.6mm thick with flanges of 22mm and 37mm at 1200mm centre to centre one flange fixed to the ceiling with dash fastener 12.5mm dia 40mm long with 6mm dia bolts to the angle hangers of 25x25x0.55mm of required length, and other end of angle hanger being fixed with nut and bolts to G.I. channels 45x15x0.9mm running at the rate of 1200mm centre to centre to which the ceiling section 0.5mm thick button wedge of 80mm with tapered flanges of 26mm each having clips of 10.5mm at 450mm centre to centre shall be fixed in a direction perpendicular to G.I. channel with connecting clips made out of 2.64mm dia x 230mm long G.I. wire at every junction including fixing the gypsum board with ceiling section and perimeter channels 0.5mm thick 27mm high having flanges of 20mm and 30mm long, the perimeter of ceiling fixed to wall/ partition with the help of rawl plugs at 450mm centre to centre with 25mm long drive-all screws @ 230mm interval including jointing and fixing to a flush finish of tapered and square edges of the board with recommended filler, jointing tapes, finisher and two coats of primer suitable for board as per manufactures specification and also including the cost of making openings for light fittings, grills, diffusers, cutouts made with frame of perimeter channels suitably fixed all complete as per drawing and specification and direction of the Engineer In Charge but excluding the cost of painting with : (Refer- CODE-A12-07 & 1/A14-04)
8.1.1 a) 12.5 mm thick tapered edge gypsum board conforming to IS: 2095- Part I. Sqm 4,469.00 0
8.1.2 Fully Perforated Gypsum Plaster Board of size 1200 x 2400x12.5 mm having approx. 13 % perforated area with perforation size and pattern as approved by the Engineer-in-charge and as per manufacturer's pecification, with all 4 side tapered and backed by acoustical tissue with NRC value not less than 0.60 (Punch gypsum board acoustic backing) (Refer-A12-07 & 3/A14-04) Sqm 963.00 0
8.1.3 1. 12.5mm thk Glass reinforced Gypsum perforated Acoustic Boards of approx. (1200 X 2500) OR (1200 X 600) sizes. Perforations of 8mm @ 18mm c-c recommended : Knauf Danoline Solopanel Q8/18 square 8x8mm perforations at 18mm c-c 2. GI framework to hold treatment composition. Framework. Saint Gobain Gypserra or similar standard 3. Isolation mount with Sylomer or similar PU based decoupler element. The bottom mount for suspending ceiling below shall have buffer piece between screws. Suspension member shall be aluminium or threaded rod of standard gauge. (Getzner Akustik 1+ Sylomer 30/ GERB or similar ) 4. Melamine foam 50mm approx. 32-40 kg/cu.m density OR FR PU foam (Bassotect G OR Astroforme or similar) 5. 15mm Elastomeric foam applied to the main ceiling slab. Density 180-240 kg/cu.m. FR rated (Kflex Kfonik OR Aramcell RD 230) 6. For Final Finish: Stable substrate, creating a seamless and acoustically monolithic finish on surface. System panel is made of randomly-spun mineral wool with factory-applied and sanded coating of recycled glass granulate, made of 82% natural and recycled materials This system is applied to a stable substrate and finished with post-consumer marble finishes. Standard and custom finishes are available to match any aesthetic or texture, and is available in any custom color. The accessories of fixing, gluing of items shall be considered within the installation process costs. Sampling or mockup of the composition prior to execution shall be provided for approval of relevant authority. Final finish shades or material moodboard shall be made available prior to finalisation. Note: HVAC duct and attenuator details, internal and external insulation types to be clarified with MEP team. (Drg no. A12-07 & 2A/A14-04) Sqm 309.00 0
8.2 Providing and fixing mineral fibre false ceiling tiles at all heights of size 595X595mm of approved texture, design and pattern. The tiles should have Humidity Resistance (RH) of 99%, Light Reflectance > 85%, Thermal Conductivity k = 0.052 - 0.057 w/m K, Fire Performance as per (BS 476 pt - 6 &7)in true horizontal level suspended on interlocking T-Grid of hot dipped all round galvanized iron section of 0.33 mm thick (galvanized @120 gsm) comprising of main T runners of 15x32 mm of length 3000 mm, cross T of size 15x32mm of length 1200 mm and secondary intermediate cross T of size 15x32 mm of length 600 mm to form grid module of size 600x600 mm suspended from ceiling using galvanized mild steel item (galvanised@80gsm) 50 mm long 8mm outer diameter M-6 dash fasteners, 6 mm diameter fully threaded hanger rod up to 1000 mm length and L-shape level adjuster of size 85x25x2 mm, spaced at 1200 mm centre to centre along main ‘T’. The system should rest on periphery walls /partitions with the help of GI perimeter wall angle of size24x24X3000 mm made of 0.40 mm thick sheet, to be fixed to the wall with help of plastic rawl plug at 450 mm centre to centre & 40 mm long dry wall S.S. screws. The exposed bottom portion of all T-sections used in false ceiling support system shall be pre-painted with polyester baked paint, for all heights. The work shall be carried out as per specifications, drawings and as per directions of the Engineer-incharge.(Refer-A12-07 & 2/A14-04)
8.2.1 With 12.5 mm thick beveled tegular mineral fibre false ceiling tile (NRC 0.7) Sqm 3,120.00 0
8.3 Providing and Fixing Channelled Woodworks perforated panels of width 192mm, thickness of 15mm and length 2400 mm, made of a Moisture resistant fibre board substrate with a laminated facing as per the approved shade (Portland Maple, Sea Beech, Siam Wood & Mystique Walnut, Interior White, Alumina Pearl) and a melamine balancing layer on the reverse side. The boards shall have a special perforation pattern where the reverse surface has a “Helmholtz” fluted perforation with consecutive 3mm wide groove followed by 13mm of visible pane. The edges of the panel shall be “tongue-and-grooved” to fix special clips for installation and seamless visual. The back of the perforated panel shall have sound absorbing non-woven Soundtex acoustical fleece hot pressed to achieve NRC of 0.6. (Average value of Absorption Co-efficient readings taken at 250 Hz, 500 Hz, 1000 Hz and 2000 Hz) as per ASTM C423 and Humidity Resistance (RH) of 70% with camber limit less than 1mm/1000mm and bow less than 1mm/300mm. (Refer-A12-07 & 9/A14-04) Sqm 318.00 0
8.4 Providing and fixing tiled false ceiling of specified materials of size 595x595 mm in true horizontal level, suspended on inter locking metal grid of hot dipped galvanized steel sections ( galvanized @ 120 grams/ sqm, both side inclusive) consisting of main "T" runner with suitably spaced joints to get required length and of size 24x38 mm made from 0.30 mm thick (minimum) sheet, spaced at 1200 mm center to center and cross "T" of size 24x25 mm made of 0.30 mm thick (minimum) sheet, 1200 mm long spaced between main "T" at 600 mm center to center to form a grid of 1200x600 mm and secondary cross "T" of length 600 mm and size 24x25 mm made of 0.30 mm thick (minimum) sheet to be interlocked at middle of the 1200x600 mm panel to form grids of 600x600 mm and wall angle of size 24x24x0.3 mm and laying false ceiling tiles of approved texture in the grid including, required cutting/making, opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc. Main "T" runners to be suspended from ceiling using GI slotted cleats of size 27 x 37 x 25 x1.6 mm fixed to ceiling with 12.5 mm dia and 50 mm long dash fasteners, 4 mm GI adjustable rods with galvanised butterfly level clips of size 85 x 30 x 0.8 mm spaced at 1200 mm center to center along main T, bottom exposed width of 24 mm of all T-sections shall be pre-painted with polyester paint, all complete for all heights as per specifications, drawings and as directed by Engineer-in-charge.
8.4.1 GI Metal Ceiling Lay in plain Tegular edge Global white color tiles of size 595x595 mm, and 0.5 mm thick with 8 mm drop; made of G I sheet having galvanizing of 100 gms/sqm (both sides inclusive) and electro statically polyester powder coated of thickness 60 microns (minimum), including factory painted after bending.(Refer-A12-07 & 11/A14-04) Sqm 345.00 0
8.5 Designing, fabricating, testing, installing and fixing in position polyester powder coated Aluminium plank (900mm wide) false ceiling with 3mm thick Aluminium sheet, with open grooves for linear as well as curvilinear portions of the building, for all heights and all levels etc. The fastening brackets of Aluminium alloy 6005 T5 / MS with Hot Dip Galvanised with serrations and serrated washers to arrest the wind load movement, fasteners, SS 316 Pins and anchor bolts of approved make in SS 316, Nylon separators to prevent bi-metallic contacts all complete required to perform as per specification and drawing. The item includes cost of all material & labour component, preparation detailed shop drawings with prior approval from Architect, the cost of all mock ups at site etc. complete including preparing shop drawings with prior approval of Architect / Engineer in charge etc. complete. (Refer -A12-07 & 4/A14-04)
8.5.1 Aluminium plank of size : 900mm x 1500mm Location : Ticketing Plaza Sqm 411.00 0
8.5.2 Aluminium plank of size : 450mm x 900mm Location : Driver's Toilet Sqm 20.00 0
8.6 Providing and fixing at all heights and location, acoustic stretched fabric false ceiling system of approved make, comprising of following components and providing NRC of _____ or better, including making cut outs for electrical conduits, networking boxes etc and openings for services and making the same good all complete as per drawings, manufacture's specification and direction of engineer in charge. Frame work : Framework shall be of cold rolled steel as per IS 513, hot dipped galvanised with 120 gsm, zinc coating as per IS 277 (both side inclusive), consisting of ceiling C-channels having web width of 50 mm, equal flanges of 32 mm and sectional thickness of 0.5 mm (+-/0.05 mm), fixed to ceiling with suitable fasteners including providing additional stud channels at openings and junctions as required as well as at locations of vertical grippers. The frame is fixed on 80mm thick plywood partition made out of 15mm thick marine grade plywood fixed on 50mm x 50mm aluminium subframe and 112mm x 50mm high 2nd quality approved teak wood wooden edge. Fabric layer: Fire retardant Fabric in approved shade, colour and texture and having minimum density 200 GSM, conforming to fire class 1 as per BS 476 part 7 and P as per BS 476 part or equivalent, is stretched, tucked and secured into the grippers in maximum possible panel sizes as approved, to obtain smooth, taut & wrinkle-free finish, with the weft and weave of the fabric in all panels oriented in one direction to achieve uniform shade. (Drg-A12-07 & 20/A14-04) Sqm 9.00 0
8.7 Providing, fabricating, and installing decorative wooden slat ceiling system as per drawings and approved details, comprising teak wood beading/slats of specified section (approx. 12 mm thick) fixed over 25×25 mm aluminium framing grid, suspended from structural slab with necessary hangers and supports, including provision of 25 mm thick acoustic board backing (Eckel/Strand, Anutone or approved equivalent) for sound absorption, complete with all required fasteners, anchors, connectors, edge trims, and finishing. The item includes preparation, melamine polishing of wooden members as specified, provision of suspended light fixtures, cutting, wastage, scaffolding, and all incidental works to complete the ceiling in line, level, and true to design, all as directed by the Engineer-in-Charge.(Refer-A12-07 & 10/A14-04) Sqm 159.00 0
8.8 Providing and fixing approved Lightweight Aluminium Access Ceiling Trapdoor as shown in the drawing. The Trapdoor shall be able to carry 12mm painted Gypsum board as per requirement to match the ceiling finish with no visible flange, and just a groove of 2-3 mm visible all around. Fixed to soffit of slab and / or ceiling frame with approved support. The lid to be connected with trap door frame with 1 or 2 Chain with each trap door and locked with 1 or 2 allen keys. The Ceiling Trapdoor shall have one or more openable Lid/Door depending upon the size of trapdoor.
8.9 Providing and fixing roofing of approved designed for installation by mechanically attaching panels to supports using concealed clips and interconnecting side edges of adjacent panels, flashing, ridges, coves, etc. manufactured out of 0.58mm. [total coated thickness (TCT)] siliconised polyester coated cold rolled high strength steel having 275MPa, yield strength sheet to have 150gms/m2 zinc aluminum alloy coating mass or equivalent approved, the weathering surface to be given a finish coat in approved shade and colour, of 20micron SMP paint over 5 micron polyster back coat over 5 micron primer and conversion coat. The rear side to have a neutral backing of epoxy primer coat of 5 micron over 5 micron polyster back coat over 5 micron primer and conversion coat, on covered walk way including insulation & calcium silicate board at bottom, painted with enamel paint system with primer etc. all complete. (Location : Walkway Refer A16-12) Sqm 474.00 0
8.10 Providing, fabricating and fixing Stainless Steel (Grade 316) flashing with 3mm thick sheet with SS (316) subframe including SS screws etc. all complete Sqm 15.00 0
TOTAL OF ROOFING & CEILING 0
9. FINISHING WORK
The rate shall include:
(i) The Plaster shall be of sufficient thickness to fill up all undulations in the surfaces of masonry and to provide a true surface for wall/ceiling plaster. Special care shall be taken to soak the walls before applying the plaster and finishing the surface of plaster to ensure uniform texture and free from air cracks. Before starting the work sufficient Number of button marks shall be done to plumb and level to achieve uniform finish
(ii) Plastering to be done either vertical face, horizontal face or angular face. Rate shall include circular /semicircular or any other shape of the faces of plastering area.
(iii) External plastering works to be inclusive of addition of integral waterproofing compound of approved make with 100 % virgin polypropylene fibrillated fibres of approved make
(iv) The contractor shall make good all the grooves, pockets etc. after the scaffolding is removed.
(v) For POP / Gypplaster items, Work to be executed after making POP level markers at every 1 metres.
(vi) The rate for all types of plaster / Punning given below should be inclusive of the following items
(a) Providing GI Chicken mesh, over lapping to a width of 150 mm at the junctions of masonry and concrete works on either side including tying in position by using suitable nails / clamps / screws and as directed etc. complete at all levels
(b) Forming of drip mould/ bands, grooves of sizes as required etc,. wherever grooves are to be provided horizontally/ vertically for in accordance with the drawings.
(c) Cost of All material and labour
(d) Hacking concrete surfaces to be plastered or rendered
(e) Preparation of surfaces by raking out joints, wetting the surface etc.,
(f) Work at all heights, levels and situations.
(g) Washing floors, cleaning glass and leaving premises clean and tidy after the plastering is done. Disposing off the debris outside the site
(h) Curing the same.
(i) Providing necessary scaffolding, ladder, platform for any height and depth and removing the same after the work is completed
(j) Neat finishing of junctions of plaster and skirting
(k) Screening and washing approved fine aggregates
(l) A 10mm groove to be made with a wooden mould at the joint of ceiling and punned wall.
9.1 Providing 10mm thick cement plaster in single coat on brick/concrete walls for interior plastering upto floor two level and finished even and smooth in (ii) Cement mortar 1:4 (1-cement :4-sand) Sqm 48,395.00 0
9.2 Providing 20 mm thick double coat mala cement plaster on brick / concrete work for plastering comprising of base coat of 12 mm thick cement plaster in cement mortar (1 Cement : 4 coarse sand) in rough finishing and 8 mm thick top coat of cement mortar 1:2 (1 Cement : 2 Coarse sand) finished with trovel including scaffolding curing etc. complete. Sqm 23,701.00 0
9.4 Extra over item 9.1 for providing and mixing water proofing materials in cement mortar in proportion recommended by the manufacturer Kg 6,120.00 0
9.6 Extra for addition of synthetic Polyester triangular fibre of length 6mm, effective diameter 10-40 microns and specific gravity of 1.34 to 1.40 in cement plaster/mortar by using 125 gms. of synthetic Polyester triangular fibre for 50 Kgs. cement used in cement mortar as per directions of Engineer-in-Charge. Kg 771.00 0
9.7 Applying two coats of putty & two coats of primer of approved brand and manufacture on new wall surface to give an even shade including thoroughly brushing the surface free from mortar dropping and other foreign matter and sand papered smooth. Sqm 18,761.00 0
9.8 Wall painting (two coats) with plastic emulsion paint of approved brand and manufacture on undecorated wall surface to give an even shade including throughly brushing the surface free from mortar droppings and other foreign matter and sand papered smooth Sqm 18,761.00 0
9.9 Providing and applying 12 mm thick (average) premixed formulated one coat gypsum lightweight plaster having additives and light weight aggregates as vermiculite/ perlite respectively conforming to IS: 2547 (Part - 1 & II) 1976, applied on hacked / uneven background such as bare brick/ block/ RCC work on walls & ceiling at all floors and locations, finished in smooth line and level etc. complete. Sqm 2,400.00 0
9.10 Finishing wall with water proofing cement paint of on wall surfaces (Two coats) to give an approved brand and manufacture and of required shape even shade after thoroughly brushing the surface to remove all dirt and remains of loose powered materials. Sqm 8,715.00 0
9.11 Finishing wall with weather proof exterior emulsion paint on wall surface (two coats) to give an required shape even shade after thoroughly brushing the surface to remove all dirt, and remains of loose powdered materials.etc complete Sqm 5,659.00 0
9.12 Supply and installation of ISOLATEK vermiculite cement based and ready - mix spray applied fireproof coating thickness shall be used to provide 120 mins of fire protection to structural steel members when tested in accordance with BS 476 part 20/21 or UL 263,ASTM E119 standards . Rate shall be inclusive of preparation of surface, application as per manufacturer's instructions, scaffolding & staging for height of 6m as required etc. complete. Sqm 16,316.00 0
9.13 Supply and installation of low VOC water based Intumescent ISOLATEK WB3 coating as a fire protective treatment with coating thickness shall be designed to provide minimum 120 mins of fire protection to structural steel members consisting portal rafter and columns when tested in accordance with BS 476 part 20/21 or UL 263,ASTM E119 standards. The fire protection system shall consist of base coat(primer)fire protection coating (water based intumescent) and finish topcoat (polyurethane). Rate shall be inclusive of preparation of surface, application as per manufacturer's instructions, scaffolding & staging staging for height of 6m as required etc. complete. Sqm 10,567.00 0
9.14 Providing and applying 2.5 mm thick road marking strips (retroreflective) of specified shade/ colour using hot thermoplastic material by fully/ semi automatic thermoplastic paint applicator machine fitted with profile shoe, glass beads dispenser, propane tank heater and profile shoe heater, driven by experienced operator on road surface including cost of material, labour, T&P, cleaning the road surface of all dirt, seals, oil, grease and foreign material etc. complete as per direction of Engineer-in-charge and accordance with applicable specifications. Sqm 500.00 0
TOTAL OF FINISHING WORK 0
10. ALUMINIUM WORK
Aluminum Windows with glass work
All work should be carried out as per specifications and drawings (refer A-13 drawings)
The rate shall include the following, in addition to the “Measurement / Rate “ as mentioned in Technical specification:
a) All materials with wastage
c) Designing, preparing shop drawing, fixing and erecting aluminium windows with heavy duty aluminium sections anodize coating as per actual site measurement
d) Aluminum alloy - IS 733
e) Extrusion - HE9WP (IS 63400 WP)
f) Fabrication and transport
g) EPDM or Neoprene Gaskets
h) Stainless steel fasteners for exposed condition and stainless steel or cadmium plated fasteners for concealed conditions.
i) Stainless steel fixtures
l) Visual Mock-ups
n) Installation
p) Warranty for 10 years on Rs. 100/- stamp paper
q) Fittings and fixtures shall be as specified in BOQ and shall be included in quoted rates
r) Run of silicon sealants around junction
s) All glass to be Low Iron (Extra clear) and be tempered (toughened)
t) All exterior glass to be DGU of adequate glass thickness with 18 mm spacer.
u) All exterior glass to have low e coating on the inner surface of exterior glass to be (Saint Gobain SKN 183 or equivalent ) Low E- coating Glass with VLT >65% & SHGF <0.4.
v) The rate shall include providing and fixing fire barrier
- Aluminium sections shall be of approved premium brand
- All fixing shall be concealed
- EPDM beading purpose made shall be provided.
- Chromotised sub frame to be fixed prior to plaster.
- EPDM gasket shall comply with 11149:1984
- Fixing shall be with SS screws.
- All beading shall be snap on type.
- Glazing beading shall be from inside only.
- Extruded sections shall comply with IS 733 ; 1956
- Hollow sections shall comply with IS 1285 : 1958
Casement Windows (Factory fabricated)
- Hinges shall be strong and with Stainless Steel pin and washers.
- Two way locking arrangement.
- Handles shall be strong / durable and finished as of aluminum.
- In fixed glazed, extruded snap-on type beading shall be provided.
- Friction stay or as approved shall be used of Stainless Steel.
- where specified lever locks shall be provided
Sliding Windows. (Factory fabricated)
- Anti-lifting device.
- Bottom rail shall be with self cleaning gutter section.
- Stainless steel ball bearings rollers.
- Concealed locking arrangement.
- Concealed tower bolts.
- All fitting and fixtures such as lever locks, handles, hinges, concealed tower bolts, etc. shall be suited to sections and be of approved make. They shall be finished in matching powder coating. Stainless steel (304 grade) Mosquito mesh of required aperture and 26 gauge with minimum 60 micron powder coated aluminium framing with prior approval before installation.
- Supply and fixing of aluminium work shall be carried out from approved agency.
- Prior to start of work supplier shall submit detailed full scale shop drawings including plan, elevation and detail of fixing with structure for approval of the PM. Samples of each item on full scale or smaller scale as directed by the PM shall be submitted for approval.
- Work shall proceed only on approval of shop drawing, samples of each extruded section, beading, gaskets, wool pile, fittings and fixtures by the PM in writing.
- Glazing shall be as noted for each unit in drawing.
- Mockup of specified samples by architects to be carried out at no extra cost.
Fixed window (Type-1)
10.2.1 W-L-G-01 of size 1095mm x 1200mm with Single pane 8mm Sqm 2.00 0
10.2.2 W-N-G-01 of size 600mm x 1200mm with Single pane 8mm Sqm 1.00 0
10.2.3 W-V-G-01 of size 450mm x 1050mm with Single pane 8mm Sqm 1.00 0
10.2.4 W-FS-G-01 of size 1350mm x 1050mm with Single pane 8mm Sqm 2.00 0
10.2.5 W-FS-G-02 of size 600mm x 1050mm with Single pane 8mm Sqm 1.00 0
10.2.6 W-C-1F-02A of size 1200mm x 1200mm with DGU glass type # 4: Insualted (8mm + 16mm +6mm) 30mm Sqm 2.00 0
Fixed window (Type-9)
10.2.7 W-A-G-09 of 600mm x 2400mm DGU glass type # 1: Inuslated (6mm + 1.5mm Laminate + 6mm + 16mm Air Gap + 8mm) 37.52mm Sqm 2.00 0
10.2.8 W-K-G-01 of size 2725mm x 1000mm DGU glass type # 4: Insualted (8mm + 16mm +6mm) 30mm Sqm 3.00 0
10.2.9 W-K-G-02 of size 1400mm x 1000mm DGU glass type # 4: Insualted (8mm + 16mm +6mm) 30mm Sqm 4.00 0
10.2.10 W-L-G-02 of size 1800mm x 950mm with Single pane 8mm Sqm 2.00 0
10.2.11 W-N-G-02, W-FS-G-02 of size 1350mm x 1000mm with Single pane 8mm Sqm 4.00 0
10.2.12 W-V-G-02 of size 1800mm x 1050mm with Single pane 8mm Sqm 2.00 0
Fixed Folding Window at 90° Window (Type-18A)
10.2.13 W-L-G-03 of size 2250mm x 1200mm with Single pane 8mm Sqm 3.00 0
Fixed Window (Type-23)
10.2.14 W-G-1F-21 of size 3900mm x 3000mm DGU glass type # 1: Inuslated (6mm + 1.5mm Laminate + 6mm + 16mm Air Gap + 8mm) 37.52mm Sqm 12.00 0
Fixed Window (Type-26)
10.2.15 W-J-4F-04 of size 15850mm x (1900mm at LHS + 2773mm at RHS) DGU glass type # 1: Inuslated (6mm + 1.5mm Laminate + 6mm + 16mm Air Gap + 8mm) 37.52mm Sqm 38.00 0
Fixed Window (Type-27A)
10.2.16 W-G-L-14 of size (1200mm at bottom + 1620mm at top) x 2400mm DGU glass type # 1: Inuslated (6mm + 1.5mm Laminate + 6mm + 16mm Air Gap + 8mm) 37.52mm Sqm 4.00 0
10.3 Designing, fabricating, testing, installing and fixing in position 5mm thick Aluminium sheet cladding, with open grooves for linear as well as curvilinear portions of the building , for all heights and all levels etc. The fastening brackets of Aluminium alloy 6005 T5 / MS with Hot Dip Galvanised with serrations and serrated washers to arrest the wind load movement, fasteners, SS 316 Pins and anchor bolts of approved make in SS 316, Nylon separators to prevent bi-metallic contacts all complete required to perform as per specification and drawing. The item includes cost of all material & labour component, preparation detailed shop drawings with prior approval from Architect, the cost of all mock ups at site, cleaning and protection of cladding till the handing over of the building for occupation. Base frame work for cladding is payable under the relevant aluminium item. Refer A14-02 Det - 12 Sqm 36.00 0
10.4 Providing and fixing 2mm thick Aluminium flashing about 100mm wide with necessary accessories as shown in drawing. (Refer-A12-08 & details A11-01 5/6/7/7A
TOTAL OF ALUMINIUM WORK 0
11 PLUMBING WORKS
11.1 SANITARY & PLUMBING FITTINGS / FIXTURES
11.1.1 Supply, Fixing, testing & commisioning of selected kohler make white coloured wall mounting european water closet (EWC), PVC seat cover, Pan connector with 'P' trap outlet with rubber buffers, flap, CP hinges, CP bolts and nuts, all of approved make etc., complete, including cutting and making good the walls and floors wherever required. (For FOH toilet) EWC (KOHLER Vive Wall-hung round-front toilet with skirted trapway, dual-flush K- 28780IN-0 or equivalent approved) Nos 84.00 0
11.1.2 Supply, Fixing, testing & commisioning of selected laufen make white coloured wall mounting european water closet (EWC), PVC seat cover, Pan connector with 'P' trap outlet with rubber buffers, flap, CP hinges, CP bolts and nuts, all of approved make etc., complete, including cutting and making good the walls and floors wherever required. (For VIP toilet) EWC (LAUFEN PRO WALL HUNG -8.2096.6.000.000+8.9896.6.000.000.1) SIZE : 355 x 545 mm (RIMLESS) Nos 3.00 0
11.1.3 Supply, Fixing, testing & commisioning of selected jaquar make white coloured wall mounting european water closet (EWC), PVC seat cover, Pan connector with 'P' trap outlet with rubber buffers, flap, CP hinges, CP bolts and nuts, all of approved make etc., complete, including cutting and making good the walls and floors wherever required. (For BOH toilet) EWC (JAQUAR - Opal Prime - OPS-WHT-15953BIUFPM - With UF Soft Close Seat Cover) Size: 370x510x360 mm Nos 20.00 0
11.1.4 Supply, Fixing, testing & commisioning of selected jaquar make white coloured orissa pan (IWC) with S/P trap, including cutting and making good the walls and floors wherever required. For FOH & BOH toilet) Indian WC (JAGUAR ECS-WHT-455, 450X535X180 mm) Nos 17.00 0
11.1.5 Supply, Fixing, testing & commisioning of selected kohler make white coloured wash hand basin with CP hinges, CP bolts and nuts, all of approved make etc., complete, including cutting and making good the walls and floors wherever required. (For FOH toilet) WASH BASIN (KOHLER 2215IN-2-0 Ladena Undercounter Basin In White) SIZE : 581 X 402 mm (UNDER COUNTER) Nos 61.00 0
11.1.6 Fixing, testing & commisioning of selected laufen make white coloured wash hand basin with CP hinges, CP bolts and nuts, all of approved make etc., complete, including cutting and making good the walls and floors wherever required. (For VIP toilet) Nos 3.00 0
11.1.7 Supply, Fixing, testing & commisioning of selected jaquar make white coloured wash hand basin with CP hinges, CP bolts and nuts, all of approved make etc., complete, including cutting and making good the walls and floors wherever required. (For BOH toilet) Nos 23.00 0
11.1.8 Supply, Fixing, testing & commisioning of selected kohler make white coloured urinal with inbuilt sensor, including CP hinges, CP bolts and nuts, all of approved make etc., complete, including cutting and making good the walls and floors wherever required. (For FOH toilet) Nos 61.00 0
11.1.9 Supply, Fixing, testing & commisioning of selected roca make white coloured urinal with inbuilt sensor, including CP hinges, CP bolts and nuts, all of approved make etc., complete, including cutting and making good the walls and floors wherever required. (For VIP toilet) Nos 2.00 0
11.1.10 Supply, Fixing, testing & commisioning of selected jaquar make white coloured urinal with CP hinges, CP bolts and nuts, all of approved make etc., complete, including cutting and making good the walls and floors wherever required. (For BOH toilet) Nos 8.00 0
11.1.11 Supply, Fixing, testing & commisioning of selected generic make SS Sink with CP hinges, CP bolts and nuts, all of approved make etc., complete, including cutting and making good the walls and floors wherever required. (For Break Room) Nos 17.00 0
11.1.12 Supply, Fixing, testing & commisioning of selected schell make flush valve with flush plate for EWC, including cutting and making good the walls and floors wherever required. (For FOH VIP, BOH & Admin toilets) Nos 124.00 0
11.1.13 Supply, Fixing, testing & commisioning of selected jaquar make sensor concealed type flush valve with flush plate for urinal, including cutting and making good the walls and floors wherever required. (For FOH & BOH toilets) Nos 69.00 0
11.1.14 Supply, Fixing, testing & commisioning of selected jaquar make sensor concealed type flush valve with flush plate for urinal, including cutting and making good the walls and floors wherever required. (For VIP toilets) Nos 2.00 0
11.1.15 Supply, Fixing, testing & commisioning of jaquar make C.P. two way bib cock with C.P. wall flange, including jointing material M-seal, glue, Teflon tap, with necessary fittings and making good the damages etc. complete. (For FOH, VIP & BOH toilets) Nos 107.00 0
11.1.16 Supply, Fixing, testing & commisioning of jaquar make C.P. health faucet, including jointing material M-seal, glue, Teflon tap, with necessary fittings and making good the damages etc. complete. (Health Faucet shall be with 4 lpm PCA insert) (For FOH, VIP & BOH toilets) Nos 107.00 0
11.1.17 Supply, Fixing, testing & commisioning of jaquar essco make C.P. bib cock with C.P. wall flange, including jointing material M-seal, glue, Teflon tap, with necessary fittings and making good the damages etc. complete. (For FOH, BOH & Admin toilets & AHU) Nos 37.00 0
11.1.18 Supply, Fixing, testing & commisioning of jaquar make C.P. sensor faucet table mounted with 450 mm long copper pipes and brass nuts, including jointing material M-seal, glue, Teflon tap, with necessary fittings and making good the damages etc. complete. (WHB Faucet shall be with 2.5 lpm PCA areator) (For FOH toilets) Nos 61.00 0
11.1.19 Supply, Fixing, testing & commisioning of jaquar make C.P. sensor faucet table mounted with 450 mm long copper pipes and brass nuts, including jointing material M-seal, glue, Teflon tap, with necessary fittings and making good the damages etc. complete. (WHB Faucet shall be with 2.5 lpm PCA areator) (For BOH toilets) Nos 23.00 0
11.1.20 Supply, Fixing, testing & commisioning of jaquar make C.P. sensor faucet table mounted with 450 mm long copper pipes and brass nuts, including jointing material M-seal, glue, Teflon tap, with necessary fittings and making good the damages etc. complete. (WHB Faucet shall be with 2.5 lpm PCA areator) (For VIP toilets) Nos 3.00 0
11.1.21 Supply, Fixing, testing & commisioning of jaquar make C.P. sink cock with swinging spout, including jointing material M-seal, glue, Teflon tap, with necessary fittings and making good the damages etc. complete. (Sink Faucet shall be with 6 lpm PCA aerator) (For janitor room sink) Nos 17.00 0
11.1.22 Supply, Fixing, testing & commisioning of jaquar make C.P. angular stop cock, including jointing material M-seal, glue, Teflon tap, with necessary fittings and making good the damages etc. complete. (For FOH, VIP & BOH toilets & kitchens, water fountain boiler provision) Nos 167.00 0
11.1.23 Supply, Fixing, testing & commisioning of jaquar make C.P. waste coupling, including jointing material M-seal, glue, Teflon tap, with necessary fittings and making good the damages etc. complete. (For FOH, VIP & BOH toilets) Nos 87.00 0
11.1.24 Supply, Fixing, testing & commisioning of jaquar make C.P. 32mm bottle trap, including jointing material M-seal, glue, Teflon tap, with necessary fittings and making good the damages etc. complete. (For FOH, VIP & BOH toilets) Nos 87.00 0
11.1.25 Supply, Fixing, testing & commisioning of geberit make P.P. 40mm P trap, including jointing material M-seal, glue, Teflon tap, with necessary fittings and making good the damages etc. complete. (For janitor room sink) Nos 17.00 0
11.1.26 Supply, Fixing, testing & commisioning of jaquar make concealed body for single lever diverter, including jointing material M-seal, glue, Teflon tap, with necessary fittings and making good the damages etc. complete. Nos 4.00 0
11.1.27 Supply, Fixing, testing & commisioning of jaquar make single lever diverter exposed parts kit, including jointing material M-seal, glue, Teflon tap, with necessary fittings and making good the damages etc. complete. Nos 4.00 0
11.1.28 Supply, Fixing, testing & commisioning of jaquar make round shape overhead shower, including jointing material M-seal, glue, Teflon tap, with necessary fittings and making good the damages etc. complete. Nos 4.00 0
11.1.29 Supply, Fixing, testing & commisioning of jaquar make shower arm, including jointing material M-seal, glue, Teflon tap, with necessary fittings and making good the damages etc. complete. Nos 4.00 0
11.1.30 Supply, Fixing, testing & commisioning of jaquar make bathtub spout, including jointing material M-seal, glue, Teflon tap, with necessary fittings and making good the damages etc. complete. Nos 4.00 0
11.1.31 Supply, Fixing, testing & commisioning of racold make electric operated hot water storage type boiler 35 lits capacity with required safety valve, 2 nos 15mm dia metal reinforced flexible connectors 300mm long. boiler shall carry min 5 kg/cm2 pressure. (For Shower) Nos 4.00 0
11.1.32 Supply, Fixing, testing & commisioning of racold make electric operated hot water storage type boiler 50 lits capacity with required safety valve, 2 nos 15mm dia metal reinforced flexible connectors 300mm long. boiler shall carry min 5 kg/cm2 pressure. (For VIP Kitchen) Nos 1.00 0
11.1.33 Supply, Fixing of nirali make C.P. cockroach Trap with perforated cover with required jointing materials for WHB, sink & other area floor traps. Nos 226.00 0
11.1.34 Supply, Fixing of chilly make CP cockroach Trap with plain cover with required jointing materials for urinals. Nos 33.00 0
11.1.35 Supply, Fixing of chilly make CP Cleanout with plain cover with required jointing materials for drain pipe of size: 75mm. Nos 249.00 0
11.1.36 Supply, Fixing of chilly make CP Cleanout with plain cover with required jointing materials for drain pipe of size: 110mm. Nos 232.00 0
11.2 INTERNAL & EXTERNAL WATER SUPPLY 0.00
11.2.1 Providing laying and jointing in true line and level U.P.V.C. Pipe (SCH-40) for cold water including fittings as approved by Engineer In Charge. Pipe shall be fixed on the wall with the help of clamp at every two metre C/C or shall be concealed as directed including necessary fittings etc. including testing of pipe and joints and fixing the same with adhesive solvent, including cost of all materials. (For tanker water supply line from external to UGR) 0.00
11.2.2 Providing laying and jointing in true line and level U.P.V.C. Pipe (SCH-80) for cold water including fittings as approved by Engineer In Charge. Pipe shall be fixed on the wall with the help of clamp at every two metre C/C or shall be concealed as directed including necessary fittings etc. including testing of pipe and joints and fixing the same with adhesive solvent, including cost of all materials. (For hydromatic / booster domestic, flushing & HVAC water supply downtale & loop upto toilet block, dewatering sump delivery line from sump to external chamber & borewell water supply line from external to UGR) 0.00
11.2.3 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes (SDR-11), having thermal stability for hot & cold water supply and all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. (For toilet internal piping from shaft to fixture) 0.00
Internal work - Exposed on wall 0.00
11.2.3.1 15 mm nominal dia Pipes Rmt 357.00 0
11.2.3.2 20 mm nominal dia Pipes Rmt 266.00 0
11.2.3.3 25 mm nominal dia Pipes Rmt 225.00 0
11.2.3.4 32 mm nominal dia Pipes Rmt 231.00 0
11.2.3.5 40 mm nominal dia Pipes Rmt 323.00 0
11.2.3.6 50 mm nominal dia Pipes Rmt 146.00 0
11.2.4 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes (SDR-11), having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings and fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. For toilet internal piping from shaft to fixture) 0.00
Concealed work, including cutting chases and making good the walls etc. 0.00
11.2.4.1 15 mm nominal dia Pipes Rmt 415.00 0
11.2.4.2 20 mm nominal dia Pipes Rmt 452.00 0
11.2.4.3 25 mm nominal dia Pipes Rmt 114.00 0
11.2.4.4 32 mm nominal dia Pipes Rmt 218.00 0
11.2.5 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes (SDR-11), having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. (For toilet internal flushing line) 0.00
11.2.5.1 65 mm nominal dia Pipes Rmt 28.00 0
11.2.5.2 80mm nominal dia Pipes Rmt 8.00 0
11.2.6 Providing & fixing of approved make Insulation to hot water lines of following sizes. Insulation shall be flexible elastomeric thermal insulation of 13mm thk for pipe dia upto 20mm & 25mm thk for pipe dia from 25mm to 50mm & 35mm thk for dia above 50mm. This will be used for toilet internal lines in walls / ceilings. All joints will also be continuously sealed with same material. All insulation should be covered with insulation tape etc. complete, as per direction of engineer in charge. 0.00
11.2.7 Providing and fixing G.I. pipes complete with G.I. fittings including trenching and refilling etc. (C-Class) (For corporation water supply line from external to UGR) 0.00
External work 0.00
11.2.7.1 80 mm nominal dia Pipes Rmt 449.00 0
11.2.8 Making connection of G.I. distribution branch with G.I. main of following sizes by providing and fixing tee, including cutting and threading the pipe etc. complete (C-Class) 0.00
11.2.8.1 50 to 80 mm nominal bore Nos 1.00 0
11.2.9 Fixing water meter and stop cock in G.I. pipe line including cutting and threading the pipe and making long screws etc. complete (cost of water meter and stop cock to be paid separately). Nos 1.00 0
11.2.10 Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) : 0.00
11.2.10.1 25 mm nominal bore Nos 15.00 0
11.2.10.2 20 mm nominal bore Nos 6.00 0
11.2.10.3 32 mm nominal bore Nos 18.00 0
11.2.10.4 40 mm nominal bore Nos 30.00 0
11.2.10.5 50 mm nominal bore Nos 25.00 0
11.2.11 Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete : 0.00
11.2.11.1 15 mm nominal bore Nos 63.00 0
11.2.12 Providing and fixing Gun metal check or non-return fullway wheel valve. 0.00
11.2.13 Providing and fixing gun metal non- return valve of approved quality (screwed end) : 0.00
11.2.13.1 50 mm nominal bore 0.00
11.2.13.1.1 Horizontal Nos 7.00 0
11.2.13.2 65 mm nominal bore 0.00
11.2.13.2.1 Horizontal Nos 2.00 0
11.2.13.3 80 mm nominal bore 0.00
11.2.13.3.1 Horizontal Nos 11.00 0
11.2.14 Supplying, fixing, testing and commissioning of butterfly valve of PN 1.6 rating with bronze/gunmetal seat duly ISI marked complete with nuts, bolts, washers, gaskets conforming to IS 13095 of following sizes as required : 0.00
11.2.15 Providing, installation, testing and commissioning of non-return valve of following sizes confirming to IS: 5312 complete with rubber gasket, GI bolts, nuts, washers etc.as required : 0.00
11.2.16 Supplying, fixing, testing and commissioning of following valves, strainers, gauges in the chilled water plumbing duly insulated to the same specifications as the connected piping and adequately supported as per specifications. 0.00
Y - STRAINER of Ductile CI Body flanged ends with stainless steel strainer for chilled / hot water circulation including insulation as specified. 0.00
11.2.17 Providing, fixing, testing & commisioning of approved make GM Air Release Valve ISI marked, including flanges / union, nuts, bolts, washer etc., complete as required. All valves shall be (PN-10) pressure rated. 0.00
11.2.18 Providing and fixing enclosed type water meter (bulk type) conforming to IS : 2373 and tested by Municipal Board complete with bolts, nuts, rubber insertions etc. (The tail pieces if required will be paid separately) : 0.00
11.2.18.1 80 mm dia nominal bore Nos 1.00 0
11.2.19 Providing and fixing PTMT Ball cock of approved quality, colour and make complete with Epoxy coated aluminium rod with L.P./ H.P.H.D. plastic ball. 0.00
11.2.19.1 25 mm nominal bore, 152 mm long, weighing not less than 440 gms Nos 3.00 0
11.2.20 Providing, fixing, testing & commisioning of approved make diaphragm type Pressure Reducing Brass Valve with filter of PN10 pressure rating, with required flanges, bolts etc. 0.00
11.2.21 Providing, fixing, testing & commisioning of approved make Digital water meter (BMS Compatible) including JT 121PP Sensor With 0.2 Mtr Wire & SS304 threaded end "T" fitting for following sizes. The cost also include all the jointing materials etc., complete as required. 0.00
11.2.21.1 50mm dia. Water pipe connection Nos 2.00 0
11.2.22 Providing, fixing, testing & commisioning of approved make Digital water meter (BMS Compatible) including JT 121PP Sensor With 0.2 Mtr Wire & SS304 stub end with MS flange "T" fitting for following sizes. The cost also include all the jointing materials etc., complete as required. 0.00
11.2.22.1 100mm dia. Water pipe connection Nos 1.00 0
11.2.22.2 150mm dia. Water pipe connection Nos 1.00 0
11.2.23 Providing and fixing approved make Medium duty airtight FRP Manhole cover & frame of following sizes for overhead water tank & dewatering sump with locking arrangements with proper nut bolts fitting, etc. complete. 0.00
11.2.24 Providing and fixing of Expansion Bellows for water supply pipes at pump delivery line for following pipe sizes, including all necessary accessories to make the system complete. 0.00
11.2.25 Providing and constructing B.B. Masonry Chamber of suitable size with cement concrete bedding 150 mm thick grade M-15, with bed projections of 100 mm on each side 150mm thickness, B.B.masonry (200mm) in cement mortor 1:5 with benching from inside with M15 grade C.C. providing 20mm Plastering with cement mortor 1:3 from inside and outside and fixing airtight double seal plain Medium duty FRP recessed covers of following sizes. including curing etc.complete as per direction of the Architect. suitable for following sizes of inspection chambers. providing and fixing 165mm width poly propylene coated steel reinforced foot rest/Rungs, horizontal 300mmc/c, in staggered manner & Vertical distance 600mm. Rates shall be inclusive of cost for escavation in soft soil or hard soil & back filling as per direction of engineer in charge. (For corporation water supply line & rain water tank valve chamber) 0.00
11.2.25.1 900 X 900mm (up to Depth of 600mm) Nos 1.00 0
11.3 INTERNAL & EXTERNAL DRAINAGE & RAIN WATER 0.00
11.3.1 Providing, laying, jointing, testing and commissioning of approved make Agriculture PVC Pipes Confirming to IS 4985:2000 laid in wall / on floor / below ceiling in shortlengths for wash hand basin / kitchen sinks to floor trap, including all required PVC fittings as per IS 7834:1987 such as 45⁰ bend / shoe bend, single Y, 87.5° bend, socket, reducer etc. with materials & labour etc. complete, jointing with approved make solvent cement solution & giving watertightness test for pipes laid in the sunken / ceiling portion with making holes in walls / floor grooving & redoing the same and proper clamp / hangers / pedistal supports wherever required necessary etc. complete, as per direction of engineer in charge. (For wash basin & urinal drain line) 0.00
11.3.1.1 P.V.C. Pipes 6 kgf / Sq.cm. 40mm dia. Rmt 298.00 0
11.3.1.2 P.V.C. Pipes 6 kgf / Sq.cm. 50mm dia. Rmt 120.00 0
11.3.2 Providing, laying and jointing in true line and level 160 diametre U.P.V.C (Type B) conforming to IS 13592-1992 with one end plain and other end socketed with rubber ring, & fittings conforming to ISI 14735-1999 of approved make for drainage system pipe line, pipe shall be jointed with each other with rubber lubricant, pipe shall be fixed on wall using of PVC clamp of the size 160 mm diametre x 210 mm length x 196 mm heigh at every 2000 mm center to center or shall be concealed in walls as directed including necessary fittings such as bends, shoes etc. including testing of pipes and joints and jointed with adhesive solvent cement including cost of all materials. Rmt 116.00 0
11.3.2.1 Providing, laying and jointing in true line and level 110 diametre U.P.V.C (Type B) conforming to IS 13592-1992 with one end plain and other end socketed with rubber ring, & fittings conforming to ISI 14735-1999 of approved make for drainage system pipe line, pipe shall be jointed with Each other with rubber lubricant, pipe shall be fixed on wall using of PVC clamp of the size 110 mm diametre x 149 mm length x 145 mm heigh at every 2000 mm center to center or shall be concealed in walls as directed including necessary fittings such as bends, shoes etc. including testing of pipes and joints and jointed with adhesive solvent cement including cost of all materials. (For toilet internal drain line) Rmt 1,290.00 0
11.3.2.2 Providing, laying and jointing in true line and level 75 diametre U.P.V.C (Type B) conforming to IS 13592-1992 with one end plain and other end socketed with rubber ring, & fittings conforming to ISI 14735-1999 of approved make for drainage system pipe line, pipe shall be jointed with Each other with rubber lubricant, pipe shall be fixed on wall using of PVC clamp of the size 110 mm diametre x 149 mm length x 145 mm heigh at every 2000 mm center to center or shall be concealed in walls as directed including necessary fittings such as bends, shoes etc. including testing of pipes and joints and jointed with adhesive solvent cement including cost of all materials. (For toilet internal drain line) Rmt 1,246.00 0
11.3.3 Providing, laying, jointing, testing and commissioning of approved make HDPE PIPES and FITTINGS for drainage systems in the dimensions d 32–315 mm in accordance with DIN EN 1519-1- 2000- 1 / DIN EN ISO 11925- 2- 2002 - 07. Discharge pipes made of tempered PE pipes with minimum reset of only 1 % -Density - 0.95 g/cm3 and fittings with smooth ends, for discharge pipes inside and outside buildings... HDPE meets the requirements of EN 12666-1 for buried discharge channels and pipes. HDPE Pipe need to supply along with necessary fittings such as, 45 deg. or 88.5 deg. bends, Tee's, Y's, access pipe and reducers. All pipe to pipe and pipe to fittings should be Butt welded / Electro Fusion Coupling as per requirement and giving water tightness test for the pipes laid in the sunken/ceiling suspended portion with making holes in brick walls/floor grooving & redoing the same and brick support whenever required necessary etc. complete. Laying as per manufacturer guidelines in accordance with DIN EN 1519-1-2000-1/DIN EN ISO 11925-2-2002-07. Including proper clamp / hangers / pedistal supports wherever required necessary etc. complete, as per direction of engineer in charge. (For all internal rain water lines) 0.00
11.3.4 Providing and fixing in position approvaed make 110X75X50mm dia. PVC Multifloor trap 50mm deep seal for embedded areas. Making proper connection with cement solvent joints, cutting chase / hole / core cut in floors / slabs and bringing the same in proper condition and shape after placing the trap in right position etc. complete, as per direction of engineer in charge. Nos 259.00 0
11.3.5 Providing and fixing in position of approved make 110X63mm dia. PVC Boss Connector above the floor trap for wash hand basin / urinals, making proper connection with cement solvent joints, cutting chase / hole / core cut in floors / slabs and bringing the same in proper condition and shape after placing the fitting in right position etc. complete, as per direction of engineer in charge. Nos 3.00 0
11.3.6 Providing & fixing of approved make UV Stabilzed PVC Cowl conforming to IS 14735:1999 for following pipe sizes with all required accessories & jointing materials etc. complete, as per direction of engineer in charge. 0.00
11.3.6.1 PVC SWR Vent Cowl 75 mm dia Nos 7.00 0
11.3.6.2 PVC SWR Vent Cowl 110 mm dia Nos 2.00 0
11.3.7 Providing & fixing of approved make PVC Cleanout Plug for following pipe sizes with all required accessories & jointing materials etc. complete, as per direction of engineer in charge. 0.00
11.3.8 Providing and fixing STUDOR MINI-VENT with global connector, airflow of 7.5 l/s with opening at -70 Pa, operating temparature -40° C to +60° C,one-way vents (AAVs), which resolve any negative transient pressure within a drainage system so it does not influence the water trap seal with required fittings to mount on the piping system with supports to place the unit in position. Exact placement to follow active drainage ventilation brand design guidelines. Nos 36.00 0
11.3.9 Providing and fixing STUDOR MAXI-VENT with global connector, airflow of 32 l/s with opening at -70 Pa, operating temparature -40° C to +60° C,one-way vents (AAVs), which resolve any negative transient pressure within a drainage system so it does not influence the water trap seal with required fittings to mount on the piping system with supports to place the unit in position. Exact placement to follow active drainage ventilation brand design guidelines. Nos 23.00 0
11.3.10 Supply, fixing and commissioing of polyethylene as per DIN EN 1825; proven Stability of 50 years; for below ground installation; overall dia of 1320 mm.; with ventilation provision; emptying via suction line DN 65 PN 10; counter flange with fire hose quick coupling 75B and 2½" blank cap and satisfy reaction to fire Class A15 . Standard odour tight top cover of 600 mm dia. clear opening; frame made of concrete material and cover made of cast iron; with raising tube, load class A15 according to EN 124 Inlet and outlet dia: DN 100 Make: ACO: Model: Lipumax PDNominal Size: NS 2 Grease Storage: 270L , Sludge Trap: 245L , Overall Capacity: 720L Art No: 3202.81.00 + 3300.14.01( With extension Pcs) Nos 1.00 0
11.3.11 Supply, fixing and commissioing of Grease separator made of polyethylene as per DIN EN 1825; proven Stability of 50 years; for below ground installation; overall dia of 1320 mm.; with ventilation provision; emptying via suction line DN 65 PN 10; counter flange with fire hose quick coupling 75B and 2½" blank cap and satisfy reaction to fire Class A . Standard odour tight top cover of 600 mm dia. clear opening; frame made of concrete material and cover made of cast iron; with raising tube, load class A15 according to EN 124 Inlet and outlet dia: DN 150 Make: ACO: Model: Lipumax PDNominal Size: NS 8.5 Grease Storage: 360L, Sludge Storage: 860L, Overall Capacity: 1900L Art No: 3208.81.00 + 3300.14.01 Nos 1.00 0
11.3.12 Supply of Grease separator made of polyethylene as per DIN EN 1825; proven Stability of 50 years; for below ground installation; overall dia of 1320 mm.; with ventilation provision; emptying via suction line DN 65 PN 10; counter flange with fire hose quick coupling 75B and 2½" blank cap and satisfy reaction to fire Class A15. Standard odour tight top cover of 600 mm dia. clear opening; frame made of concrete material and cover made of cast iron; with raising tube, load class A15 according to EN 124 Inlet and outlet dia: DN 150 Make: ACO: Model: Lipumax PDNominal Size: NS 10 Grease Storage: 415L, Sludge Storage: 1010L, Overall Capacity: 2170L Art No: 3210.81.00 + 3300.14.01( With extension Pcs) Nos 1.00 0
11.3.13 Providing and fixing PVC Bottle Gully Traps of size 150 x 100mm Dia in BBM chamber & supported with PCC M15 grade. 0.00
11.3.13.1 PVC SWR Gully Trap 160 x 110 Nos 18.00 0
11.3.14 Providing, lowering & laying including supply of materials and labour for SN4/SN8 Rigid PVC pipe of standard make, with necessary cutting to the required length including short pieces with assorted fittings, Separate coupler with unique design of click ring and rubber – sealing rings upto 250mm (Solvent weld and rubber ring upto 250mm pipe) & above pipe dia. with solution/ push fit jointing, (Solvent weld type coupler for 315mm & 400mm pipe) and giving water tightness test for the pipes laid. All the pipes which will be laid in soil / filling shall be properly supported at all joints, change in dia, direction.etc. works to be executed as per IS complete as per direction of engineer in charge. (For external sewer drain lines) 0.00
11.3.15 Providing laying (to level or slopes) and jointing reinforced concrete Light duty non-pressure pipes I.S. class NP2 of the following internal diameter with collars and butt ends prepared for collar joints including testing of joints complete. (For external storm water line) 0.00
11.3.16 Providing and constructing BBM chamber of size 300 x 300 & cement concrete M15, chamber is smooth finishing from inside & outside with CM 1:3 including FRP recessed grating medium duty cover over the gully trap. Nos 18.00 0
11.3.17 Providing and constructing B.B. Masonry Chamber of suitable size with cement concrete bedding 150 mm thick in 1:6 cement mortar bedding projecting 150mm and benching from inside with 1:2:4 C.C. and plastering with cement mortar 1:3 from inside and outside. Including providing and fixing precast Plain FRP recessed Covers along with frame including providing and fixing C.I. steps 300mmc/c Benching in M15 and finishing with cement punning inside, including curing, excavation etc. complete, as per direction of engineer in charge. 0.00
11.3.17.1 600 X 600mm (up to 450mm depth) (MD Cover) Nos 43.00 0
11.3.17.2 900 X 450mm (up to 450mm depth) (MD Cover) Nos 27.00 0
11.3.17.3 900 X 900mm (up to 1000mm depth) (MD Cover) Nos 36.00 0
11.3.18 Same as item no. 16.0, for chamber depth as below. Rate per meter of chamber. 0.00
11.3.18.1 600 X 600mm (depth above 450mm) Rmt 14.43 0
11.3.18.2 900 X 450mm (depth above 450mm) Rmt 10.31 0
11.3.18.3 900 X 900mm (depth above 1000mm) Rmt 28.52 0
11.3.19 Providing, laying & fixing 150mm dia. sewer trap / master trap (PVC) inside the manhole as per direction of the Site Incharge including making good the damages, if made while fixing the sewer trap etc. complete. Nos 1.00 0
11.3.20 Providing and fixing RCC grating, with angle frame 50 x 50 x 5 to suit the clear span of the gutter,thickness of the perforated cover shall be suitable for below mentioned load application. 0.00
11.3.20.1 Size of trench 300mm wide meadium duty Rmt 619.00 0
11.3.21 Providing and fixing in position of approved make S.S. Dome Type Roof Drain, at the entrance of RWP on terrace with all necessary fittings, making proper connection with cement solvent joints, cutting chase / hole / core cut in floors / slabs and bringing the same in proper condition and shape after placing the in right position complete as per direction of engineer in charge. 0.00
11.3.21.1 Aco HP vertical spigot outlet - Dome grate (75mm outlet) (Article number: 105901) Nos 27.00 0
11.3.21.2 Aco HP vertical spigot outlet - Dome grate (110mm outlet) (Article number: 105902) Nos 20.00 0
11.3.21.3 Aco HP vertical spigot outlet - Dome grate (160mm outlet) (Article number: 105903) Nos 33.00 0
11.3.22 Providing and fixing in position of approved make Roof Corner Outlet with all necessary fittings, making proper connection with cement solvent joints, cutting chase / hole / core cut in floors / slabs and bringing the same in proper condition and shape after placing in right position complete as per direction of engineer in charge. 0.00
11.3.22.1 Aco 2 way roof / balcony outlet (260 x 260 dia, 160mm outlet) (Article number: 155304) Nos 6.00 0
11.3.22.2 Aco 2 way roof / balcony outlet (205 x 205 dia, 110mm outlet) (Article number: 155303) Nos 2.00 0
11.3.22.3 Aco 2 way roof / balcony outlet (170 x 170 dia, 75mm outlet) (Article number: 155300) Nos 1.00 0
11.3.23 Providing and fixing in position of Prefab Polymer Concrete ACO Drain V 100 Multiline Channels as per EN 1433 having following properties a) Compressive strength -96 N/mm2 b) Flexural strength -27N/mm2 c) Water absorption - 0.07% d) Manning's roughness- 0.011. The Channels must be 'V'-profile in shape with integrated edge protection made up of Galvanised Steel with boltless drainlock®grating with anti-shunt 4 no. provision per length. The Channels must also be pre-sloped 1:200 or same invert / variable depth with 500 or 1000 mm length and with tongue and groove joints for interlocking, integrated lip labyrinth sealing for liquid-tight connection to ground line with needed accessories like end cap, end cap with outlet etc. Channels to have anchoring features on the outside wall to ensure mechanical bond to the surrounding bedding material and pavement surface.The Channel gratings are made up of Polypropelene in L500 mm length, suitable for polymer concrete drain channels as per load class A -15, B-125, C250 , D 400, E 600 confirming to EN 1433. The Channels will have the nominal width of 100 mm and invert depth varying between 100-250 mm as per design.Composite plastic PP bar grate Microgrip, anthracite black with patented anti-slip surface structure, slip resistance class R13 according to DIN 51130 type Heelguard with slot width 8mm, inlet cross section 284 cm² / m with TPU snap fit locking and certified for load class B125 as per EN 1433. Rmt 454.00 0
11.3.24 Providing and fixing in position of ACO Mod. Custom Curve Channel without edge infill, SS304- (L9210 of R5305 + L8655 of R5310), W=100, H=200/120 (stepped gradient), with DN110 Hz. outlet, with SS Lockable grate, Slotted Design with Powder coating, LC A15 (pedestrian)- (channel as per ML-V100 profile with bottom angle 140* & SS grate as per V100 PP grate) Set 1.00 0
11.3.25 Providing and fixing in position of Prefab Polymer Concrete Euroline Channels in accordance to DIN EN 1433 with following properties. a) Compressive strength -96 N/mm2 b) Flexural strength -27 N/mm2 c) Water absorption - 0.07% d) Mannings roughness- 0.011. The Channels will be 'V'-profile in shape with screw less locking grating, without slope. The Channels interlocking shall be with tongue and groove joints and are with anchoring features on the outside wall to ensure mechanical bond to the surrounding bedding material and pavement surface. The channels will be with knock-out preform for connection to 110mm pipe, provided with inbuilt bottom outlet suitable for DN 100 and with all range of accessories like end plate / end plate with outlet suitabel for DN 60. The Channel gratings will be made up of ductile iron/ Galv. Steel / Stainless Steel 304/ PP in 500 mm / 1000 mm length suitable as per load class A-15 / B-125 / C-250 confirming to EN 1433. The Channels nominal width will be 98 mm with overall width 118 mm and invert depth of the drain 55 mm as per design. Dimensions : 1000x118x97 (LxWxH ), Height (Composite plastic PP bar grate with Microgrip, anthracite black with anti-slip surface structure, type Heel guard with slot width 8mm, inlet cross section 254 cm²/m and certified for load class A-15 as per EN 1433. Art. No: 319250 / 319251 Rmt 120.00 0
11.3.28 Providing and fixing M.S. fabricated angle bracket of required size in 50x50x50mm double angle for water supply & drainage pipe in shaft. Bracket shall be placed so that there is no wrapping of pipes. Bracket shall be painted with red oxide paint & 2-coat of enamel paint with "U" clamp nut & bolts, grounting in wall / dash fastness etc. complete. Kg 2,681.00 0
11.3.29 Providing and fixing Puddle flanges of required sizes in RCC structures at locations and levels as shown on the drawing, fabricated MS hot dip galvanized finish pipes assembly with 5mm wall thickness upto 65 mm nominal bore pipes and 6 mm wall thickness for 80mm or above diameter pipes welded to 5mm thick square plate of size 3 times the diameter of the pipe. Puddle flanges upto 50mm n.b shall have screwed ends whereas pipes of larger diameters shall be provided with flanges of approved sizes on both ends. Overall length of the puddle flange pipe shall be such that it will project 150mm/200mm on either side of the wall. The average length of the puddle flange shall be maximum 900mm in length. Kg 1,000.00 0
11.4 CIVI WORK FOR PLUMBING SYSTEM 0.00
11.4.1 Providing and laying cement concrete 1:2:4 (1- Cement : 2- Coarse sand : 4- graded stone aggregates 20 mm nominal size) and curing complete excluding cost of formwork in (A) Foundation and Plinth (For pipe PCC) Cum 95.00 0
TOTAL CARRIED OVER TO SUMMARY 0.00
11.5 PHE PUMPING SYSTEM 0.00
11.5.1 Providing & Installing of Vertical Inline pumping system for Direct feeding Domestic water from UGR to Toilets on hydropneumatic VFD system: Control Panel must be PLC based IP55 protection with following features: a. Ammeter for individual pump b. Voltmeter c. Phase Reversal preventer d. Single phase preventer e. Automatic sequence change to ensure equal run time for all pumps. f. Panel diagram to be get approved from electrical consultant before finalization. g. Dry run prevention. h. Overheating indication of pump motor & motor shall trip in case of overheating. i. Panel shall have sufficient potential free contact for BMS compatibility. System shall have pressure transducer for operation of pumps. Pump discharge for each pump, Q = 175 lpm @ head of 65m. No of pumps = 2 working + 1 stand by (All pumps with VFD & All component shall be PN 10) Application: - feeding of Domestic water from UGR to Toilets & OHT filling: (Header diameter is 100 NB). Pump body shall be in CI. Impeller, shaft & all wetted parts shall be in SS 304. Keep Cut in set point as 6.0kg/cm2 & cut off set point as 7.0kg/cm2. Set 1.00 0
'11.5.2 Providing & Installing of Vertical Inline pumping system for Direct feeding Flushing water from STP to Toilets on hydropneumatic VFD system: Control Panel must be PLC based IP55 protection with following features: a. Ammeter for individual pump b. Voltmeter c. Phase Reversal preventer d. Single phase preventer e. Automatic sequence change to ensure equal run time for all pumps. f. Panel diagram to be get approved from electrical consultant before finalization. g. Dry run prevention. h. Overheating indication of pump motor & motor shall trip in case of overheating. i. Panel shall have sufficient potential free contact for BMS compatibility. System shall have pressure transducer for operation of pumps. Pump discharge for each pump, Q = 330 lpm @ head of 65m. No of pumps = 2 working + 1 stand by (All pumps with VFD & All component shall be PN 10) Application: - feeding of Flushing water from STP to Toilets: (Header diameter is 150 NB). Pump body shall be in CI. Impeller, shaft & all wetted parts shall be in SS 304. Keep Cut in set point as 6.0kg/cm2 & cut off set point as 7.0kg/cm2. Set 1.00 0
'11.5.3 Providing & Installing of Vertical inline pumping system for feeding of HVAC Cooling towers (at terrace floor) from UGR: Control Panel must be PLC based IP55 protection with following features: a. Ammeter for individual pump b. Voltmeter c. Phase Reversal preventer d. Single phase preventer e. Automatic sequence change to ensure equal run time for all pumps. f. Panel diagram to be get approved from electrical consultant before finalization. g. Dry run prevention. h. Timer system for start & stop of pumps. (Real time timer) i. Over heating indication of pump motor & motor shall trip in case of overheating. j. Panel shall have sufficient potential free contact for BMS compatibility. System shall have pressure transducer for operation of pumps. Pump discharge for each pump, Q = 110 lpm @ head of 55m. No of pumps = 1 working + 1 stand by (All component shall be PN 10) Application: - feeding of HVAC Cooling towers (at terrace floor) from UGR: (Header diameter is 50 NB) Set 1.00 0
'11.5.4 Providing & Installing of Submersible pumps for UGR & STP pump-room sump water pumping to nearest storm water chamber: Pump discharge for each pump, Q = 200 lpm, at head 15.00 m No of pumps = 1 working + 1 stand by. (Solid handelling:20mm, MOC: CI body, SS304 Impeller) PLC based Control Panel to have following features: a. Ammeter for individual pump b. Voltmeter c. Phase Reversal preventer d. Single phase preventer e. Automatic sequence change to ensure equal run time for all pumps. f. Panel diagram to be get approved from electrical consultant & BMS consultant before finalization. g. Dry run prevention. h. Overheating indication of pump motor & motor shall trip in case of overheating. i. Panel shall have sufficient potential free contact for BMS compatibility. All sump pumps shall be able to work on 2 floats (1st float-high high & high low 2nd float low high & low low) Panel should have IP 55 protected. Note- 1. Provide pump curve with duty point marked on the same. 2. Manifold, NRV & valves on supply & delivery are in vendor supply scope. Manifold shall be in SCH 80 UPVC/C-PVC pipes or GI ‘C’ class pipes. Set 2.00 0
'11.5.5 Providing & Installing of Submersible pumps for transfer of stored rain water from Rain water storage tank: Control Panel must be PLC based IP55 protection with following features: a. Ammeter for individual pump b. Voltmeter c. Phase Reversal preventer d. Single phase preventer e. Automatic sequence change to ensure equal run time for all pumps. f. Panel diagram to be get approved from electrical consultant before finalization. g. Dry run prevention. h. Timer system for start & stop of pumps. (Real time timer) i. Over heating indication of pump motor & motor shall trip in case of overheating. j. Panel shall have sufficient potential free contact for BMS compatibility. System shall have pressure transducer for operation of pumps. Pump discharge for each pump, Q = 250 lpm @ head of 15m. No of pumps = 1 working + 1 stand by (All component shall be PN 10) Application: - Transfer of stored rain water from Rain water storage tank: (Header diameter is 80 NB) Set 1.00 0
TOTAL CARRIED OVER TO SUMMARY 0.00
11.6 Supply, installation, testing and comissioning of Heat pumps. Details as per Annexure 3 of Heat pump Technical Specifications Document. Lumpsum 2.00 0
11.7 Supply, installation, testing and comissioning of SEWAGE TREATMENT PLANT using CAMUS-SBT TECHNOLOGY of 170M3 PER DAY capacity and details and parameters as per Annexure 2 of Technical Specifications Document and STP Schematic Layout Drawing Nos 1.00 0
11.8 Supply installation, testing and commissioning of dometic water treatment plant comprising of Multigrade sand filter and softner Plant accrording to input water quality/analysis. softner plant consisting of FRP tank, filter media, resins, brine tank, piping, isolation valves, instruments supports. The scope shall include interconnection piping, valves, instruments, autoback wash arrangement, Brine preparation tank & agitator platform (Make: FRP), 1 nos. Agitator require capacity and Ventury etc. complete the job ..Scope shall also includes training for operation of staff. Inlet Flow Range : 12 CMT/ Hr. Input Water Hardness : ‐( as per water test report) Output Water Hardness : < 50 PPM MULTI‐ GRADE PRESSURE SAND FILTER:Flow Rate : 12 cum/hr Filter Media : Silica, Pables, Gravels And Quartz Sand Size : 700MM Diameter NOTE- Annexure 1 of Technical Specifications Document for WTP design parameters, rate inclusive of cost of water quality test for input parameters and system details of WTP Nos 1.00 0
11.9 Construction of Percolation Well with all required connections as per detailed design 3mtr dia X 4 mtr liquid depth + invert Level) for catch basin with FRP Heavy duty manhole cover and overflow connection to the nearest drain. Etc. complete. Nos 3.00 0
TOTAL OF PLUMBING WORKS 0
12 FIRE FIGHTING WORKS
12.1.1 Supplying, installation, testing and commissioning of Electric driven Main Fire Pump suitable for automatic operation and consisting of following, complete in all respects, as required : (a) Horizontal type, multistage, centrifugal, split casing pump of cast iron body & bronze impeller with stainless steel shaft, mechanical seal gland pack conforming to IS 1520. (b) Suitable HP Squirrel cage induction motor, TEFC, synchronous speed 1500 RPM, suitable for operation on 415 volts, 3 phase 50 Hz, AC supply with IP 55 protection for enclosure, horizontal foot mounted type with Class-'F' insulation, conforming to IS-325. (c) M.S. fabricated Common base plate, coupling, coupling guard, foundation bolts etc. as required. (d) Suitable cement concrete foundation duly plastered with anti vibration pads. Note: *The head of the pump is selected in a manner so as to give a minimum 3.5kgf/cm2 pressure at the highest/farthest point.
12.1.1.1 2850 lpm at 100 m Head Set 3.00 0
12.1.2 Supplying, installation, testing and commissioning of diesel engine driven main fire pump suitable for automatic operation and consisting of following, complete in all respects, as required : (Diesel Driven Pump) Horizontal type, multistage, centrifugal pump of cast of iron body and bronze impeller with stainless steel shaft, mechanical seal gland pack conforming to IS 1520. Suitable HP, 1500 RPM water cooled with radiator, diesel engine conforming to relevant IS standard complete with auto starting mechanism, 12 /24 volts electric starting equipment, diesel tank, exhaust pipe extended upto 10 m outside pump house duly insulated with 50 mm thick glass wool with 1.0 mm thick aluminium sheet cladding, residential silencer, instruments and protection as per standard specification, stop solenoid for auto stop in the event of fault with audio indications, painted with post office red colour etc. as required. M.S fabricated, common base plate, coupling, coupling guard, foundation bolts etc. as required. Suitable cement concrete foundation duly plastered and with anti vibration pads. Note: * The head of the pump is selected in a manner so as to give a minimum 3.5kgf/cm2 pressure at the highest/farthest point. 0.00
12.1.2.1 2850 lpm at 100 m Head Set 1.00 0
12.1.3 Supplying, installation, testing and commissioning of electric driven pressurisation pump suitable for automatic operation and consisting of following, complete in all respects, as required : (Jockey Pump) Horizontal vertical inline type, multistage, centrifugal pump of cast iron body and bronze impeller with stainless steel shaft, mechanical seal conforming to IS : 1520. Suitable HP squirell cage induction motor TEFC type suitable for operation on 415 volts, 3 phase 50 Hz AC supply with IP 55 class of protection for enclosure, horizontal foot mounted type with Class-'F' insulation, conforming to IS : 325. M.S.fabricated Common base plate, coupling, coupling guard, foundation bolts etc. as required. Suitable cement concrete foundation duly plastered and with anti vibration pads. 0.00
12.1.3.1 180 lpm at 100 m Head Set 2.00 0
12.1.4 Supplying, installation, testing and commissioning of electric driven terrace pump suitable for automatic operation and consisting of following, complete in all respects, as required: (Terrace Pump) (a) Horizontal type, multistage, centrifugal, split casing pump of cast iron body & bronze impeller with stainless steel shaft, mechanical gland pack confirming to IS : 1520 b) Suitable HP squirell cage induction motor TEFC type suitable for operation on 415 volts, 3 phase, 50 Hz, AC supply with IP55 class of protection for enclosure, horiziontal foot mounted type with Class-'F' insulation, conforming to IS-325. (c) M.S.fabricated common base plate, coupling, coupling guard, foundation bolts etc.as required. (d) Suitable cement concrete foundation duly plastered and with anti vibration pads. 0.00
12.1.4.1 900 lpm at 45 m Head Set 3.00 0
12.2 CONTROL PANELS 0.00
12.2.1 Supply, installing, testing and commissioning of Fully automatic pump starter panel having following drives standby pump (1 No.), Sprinkler (1 No.), hydrant pump (1 No.), jockey pump (2 Nos.), & complete with over current protection Control panel to be made out of 16 SWG CRCA sheet powder coated. Control panel comprise of (a) Fully automatic starter for suitable HP rating with suitable range of overload relay protection with facility of Manual & Auto operation based on pressure switch logic (b) 1 no. voltmeter of range 0.500 `v’, AC 50Hz. supply & voltage selector switch mounted on it. (c) 1no. Ammeter of suitable range, AC 50Hz, supply with ammeter selector switch. (d) 3 no. indicating lamps with requisite protective fuses (a) 1 no. Main MCCB. of required capacity & specification (f) switches for auto manual operation to main pump, jockey pump. All material must be as per IS. Panel Shall be provided with required no. potential free contact for BMS compatibility. Status of all F.F. pumps will be monitored (FF pumping system shall be charged at all time & pumps will operate on pressure setting of pressure transducer.) This panel will be checked & approved by Electrical consultant for the project. First jockey pump will start at drop of 95% of the system pressure, main hydrant will start at 85% of the system pressure & standby pump will start at 65% of drop in system pressure. All electrical & control wiring from panel to pump will be in the scope of panel supplier. Rate of same shall be included in the panel cost. Main electrical supply to FF Pump panel will be in the scope of main electrical vendor. This panel will be checked & approved by Electrical consultant for the project. Vendor to consider the all requisite components / provisions for the IOT based monitoring of Fire Pump & System as per the Fire NOC compliance. (System Pressure, Pump ON/OFF, Historic Data for 12 months etc) Set 1.00 0
12.2.2 Supply, installation, testing and commissioning of DOL starter (ON/OFF switch) for the Booster pump. Set 6.00 0
12.2.3 Supply and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable. 0.00
12.2.4 Supply installing testing & commissioning of G.I. strips for earthing of below sizes. 0.00
12.2.5 Supply & installing below type cable trays with structural supporting as per approved drawing and on floor supporting shall be shall be with structural & RCC pedestals. 0.00
12.2.5.1 450mm X 75 mm Ladder type Rmt 25.00 0
12.2.5.2 100mm X 50 mm perforated type Rmt 30.00 0
12.3 PIPES & ACCESSORIES 0.00
12.3.1 Providing laying, testing & commissioning of 'C' class heavy duty GI Pipe conforming to IS 1239/3589 i/c fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. in ground including welding, excavation & providing cement concrete blocks as supports, anticorrosive treatment (pypkote) with coaltar/asphalt tape as per IS 10221, refilling the trench etc. of following sizes complete as required. 0.00
12.3.2 Providing, laying, testing & commissioning of 'C' class heavy duty GI pipe conforming to IS 3589/IS 1239 including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required : 0.00
12.3.2.8 200 mm dia (wall thickness 6.3 mm) Rmt 15.00 0
12.3.2.9 250 mm dia (wall thickness 6.3 mm) Rmt 28.00 0
12.3.3 Supplying and fixing single headed internal hydrant valve with instantaneous Gunmetal/Stainless Steel coupling of 63 mm dia with cast iron wheel ISI marked conforming to IS 5290 (Type -A) with blank Gunmetal/Stainless Steel cap and chain as required : 0.00
12.3.3.1 Single headed Stainless steel Set 64.00 0
12.3.4 Supplying and fixing Single headed external yard hydrant valve with 1 No. 63 mm dia instantaneous FM Gunmetal/Stainless Steel coupling and cast iron wheel, ISI marked, conforming to IS 5290 (type A) with blank Gunmetal/Stainless Steel cap and chain as required : 0.00
12.3.4.1 Single headed Gunmetal Set 15.00 0
12.3.5 Supplying, fixing, testing and commissioning of butterfly valve of PN 1.6 rating with bronze/gunmetal seat duly ISI marked complete with nuts, bolts, washers, gaskets conforming to IS 13095 of following sizes as required : 0.00
12.3.6 Supplying and fixing orifice plate made out of 6 mm thick stainless steel (Grade 304) with orifice of required size to be fitted between flange & landing valve of external and internal hydrants to reduce pressure at the outlet to the level of 3.5 kg/cm2 complete as required. Nos 79.00 0
12.3.7 Supplying, fixing, testing & commissioning of double flanged sluice valve of rating PN 1.6 with non rising spindle, bronze/gun metal seat, ISI marked complete with nuts, bolts, washers, gaskets and conforming to IS 780 of following sizes as required : 0.00
12.3.8 Providing, installation, testing and commissioning of non-return valve of following sizes confirming to IS: 5312 complete with rubber gasket, GI bolts, nuts, washers etc.as required : 0.00
12.3.9 Providing, installation, testing and commissioning of stainless steel Y-strainer fabricated out of 1.6 mm thick stainless steel, Grade 304, sheet with 3 mm dia holes with stainless steel flange. 0.00
12.3.10 Supplying and fixing 63 mm dia, 15 m long RRL hose pipe with 63 mm dia male and female couplings duly bound with GI wire, rivets etc. conforming to IS 636 (type-A) as required : 0.00
12.3.10.1 Stainless Steel (Grade 304) Set 158.00 0
12.3.11 Supplying and fixing first-aid Hose Reel with MS construction spray painted in post office red, conforming to IS 884 complete with the following as required. 20 mm nominal internal dia water hose thermoplastic (Textile reinforced) type -2 as per IS: 12585 20 mm nominal internal dia gun metal globe valve & nozzle. Drum and brackets for fixing the equipmets on wall. Connections from riser with 25 mm dia stop gun metal valve & M.S. Pipe and socket. 0.00
12.3.12 Supplying & fixing 63 mm dia gun metal short branch pipe with 20 mm nominal internal diameter size nozzle conforming to IS 903 suitable for instantaneous connection to interconnect hose pipe coupling as required : 0.00
12.3.12.1 Stainless Steel (Grade 304) Nos 79.00 0
12.3.13 Supply, fixing, testing and commissioning of fire cabinet of size not less than 0.75 x 0.6 x 0.25 mtr made out of M.S. sheet not less than 16 SWG thick having central opening and 4 mm thick glazed acryclic sheet doors (Two nos.) suitably marked on the outside 'with the letters "FIRE HOSE" including necessary locking arrangement and painting in red colour suitable to accommodate, and painted in red along with GI support angles for internal hydrants. Nos 64.00 0
12.3.14 Supply, fixing, testing and commissioning of fire cabinet of size not less than 0.75 x 0.6 x 0.25 mtr made out of FRP sheet not less than 16 SWG thick having central opening and 4 mm thick glazed acryclic sheet doors (Two nos.) suitably marked on the outside 'with the letters "FIRE HOSE" including necessary locking arrangement and painting in red colour suitable to accommodate, and painted in red along with GI support angles for external hydrants. Nos 15.00 0
12.3.15 Supplying and fixing of fire brigade connection of cast iron body with SS 304 male instantaneous inlet couplings complete with cap and chain as reqd. for suitable dia GI pipe connection conforming to IS 904 as required : 0.00
12.3.15.1 2 way-100 mm dia G.I. Pipe Set 2.00 0
12.3.15.2 4 way - 150 mm dia G.I. Pipe Set 2.00 0
12.3.16 Supplying and fixing air vessel made of 250 mm dia, 8 mm thick MS sheet, 1200 mm in height with air release valve on top and flanged connection to riser, drain arrangement with 25 mm dia gun metal wheel valve with required accessories, pressure gauge and paintingwith synthetic enamel paint of approved shade as required. Set 2.00 0
12.3.17 Providing, fixing, testing & commissioning of 15mm dia quartzoid bulb type sprinklers of rating 68 degree centigrade with required accessories : 0.00
12.3.17.1 Pendent Sprinkler Nos 710.00 0
12.3.17.2 Upright Sprinkler Nos 2,611.00 0
12.3.17.3 Horizontal side wall sprinkler Nos 9.00 0
12.3.17.4 Concealed sprinkler Nos 743.00 0
12.3.17.5 Concealed side wall sprinkler K80 Nos 4.00 0
12.3.17.6 Vertical side wall sprinkler K80 for façade protection Nos 218.00 0
12.3.18 Providing & fixing of pressure switch in M.S. pipe line including connection etc. as required. Nos 6.00 0
12.3.19 Providing & fixing flow switch in following sizes M.S. pipe including connection etc as required. 0.00
12.3.20 Providing, fixing, testing & commissioning of installation control valve of cast iron body, brass/bronze working parts comprising of water motor alarm, bronze seat clapper, clapper arm and hydraulically driven mechanical gong bell to sound continuous alarm when the wet riser/sprinkler system activates, pressure gauges, emergency releases, strainer, pressure switch, cock valve complete with drain valve and bypass, test control box, ball valves, MS pipe of required size, flanges, orifice plate, gasket etc of follwing sizes as required : 0.00
12.3.21 Supplying, installation, testing & commissioning of sprinkler flexible pipe (UL Listed) of stainless steel complete with 15 NPT on reducer thread with maximum working pressure of 175 PSI test pressure of 875 PSI (Burst) with branch line (Inlet) 25mm NPT male thread to sprinkler head (Outlet) 15mm NPT female thread with reducer, nipple, 2 side brackets, center bracket, stockbar of following sizes complete as required. 0.00
12.3.22 Providing, installation, testing & commissioning of adjustable rosette plate for 15mm dia in white finish UL Listed or FM approved complete as required. Nos 709.00 0
12.3.23 Supply & Installation of approved make brass Ball Valve of PN 16 of following below sizes, with all necessary accessories to make the system complete. 0.00
12.3.24 Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) : 0.00
12.3.24.1 25 mm nominal bore Nos 91.00 0
12.3.24.2 50 mm nominal bore Nos 40.00 0
12.3.25 Providing and fixing in position the industrial type pressure gauges with gun metal / brass valves complete as required Nos 38.00 0
12.3.26 Supplying and installation of approved make expansion bellows for pipes for following pipe sizes, including all necessary accessories to make the system complete. (For punp suction & delivery line) 0.00
12.3.27 Supplying and installation of approved make FM & UL approved expansion bellows for pipes crossing expansion joint for following pipe sizes, including all necessary accessories to make the system complete. (For building expantion joints) 0.00
12.3.28 Supplying and installation of Test & drain valve PN 16 including all required accessories for automatic sprinkler testing as complete with necessary accessories as per IS standard. Nos 16.00 0
12.3.29 Supply, installation, testing & commissioning of 25mm dia gun metal air release valves of PN 16 of approved make on the top of wet riser as per standard fire practice, with all necessary accessories to make the system complete. Nos 22.00 0
12.3.30 Supply, installation testing & commissioning of of approved make Flow Meter with required fittings, located at Fire pump house. Flow meter Meter shall be suitable for a pump of 4275 lpm discharge and least count shall not be more than 200 lpm Nos 1.00 0
12.3.31 Supply & Installation of 2 core 1mm2 FRLS red colour armoured cable from each flow switch up to Sprinkler annunciation panel in the basement. Rmt 90.00 0
12.3.32 Supply & Installation of FM & UL approved 32mm Standard Universal Lateral OR Longitudinal Brace Nos 80.00 0
12.3.33 Supply & Installation of FM & UL approved 80mm Standard Universal Lateral OR Longitudinal Brace Nos 137.00 0
12.3.35 Supply & Installation of FM & UL approved 150mm Standard Universal Lateral OR Longitudinal Brace Nos 715.00 0
12.3.36 Supply & Installation of FM & UL approved Universal Structural Attachment 15mm Mounting Hole, EG for bracing. Nos 932.00 0
12.3.37 Supply & Installation of HILTI Safety stud anchor [HST3 M12x115] for bracing. Nos 932.00 0
12.4 FIRE FIGHTING APPLIANCES 0.00
12.4.1 Supply and installation of portable fire extinguishers, ISI marked of following Capacity. 0.00
12.4.1.1 Co2 fire extinguisher (4.5 K.G.) , IS : 15683 : 2018 Nos 14.00 0
12.4.2 Supply and installation of portable fire extinguishers (A,B,C Type powder) with all accessories as per manufacture's specification., IS : 15683 : 2018 0.00
12.4.2.1 6 Kg Capacity Nos 174.00 0
12.4.3 Supply and installation of portable fire extinguishers with all accessories as per manufacture's specification. Capacity 45Ltrs AFFF Foam type Extinguisher trolly mounted. Nos 2.00 0
12.4.4 Supply and installation of fireman axe as per IS 926, made from forged steel with rubber insulated handle, tested to 20,000 volts Nos 1.00 0
12.4.5 Supply and installation of Fire buckets including stand with paint, etc. as complete for sand (9 lit. capacity, Three buckets with stand). Set 1.00 0
12.5 CIVIL ITEMS 0.00
12.5.1 Providing laying (to level or slopes) and jointing reinforced concrete Light duty non-pressure pipes I.S. class NP2 of the following internal diameter with collars and butt ends prepared for collar joints including testing of joints complete. 0.00
12.5.2 Providing and constructing B.B. Masonry Chamber of suitable size with cement concrete bedding 150 mm thick in 1:6 cement mortar bedding projecting 150mm and benching from inside with 1:2:4 C.C. and plastering with cement mortar 1:3 from inside and outside. Including providing and fixing precast Plain FRP recessed Covers along with frame including providing and fixing C.I. steps 300mmc/c Benching in M15 and finishing with cement punning inside, including curing, excavation etc. complete, as per direction of engineer in charge. 0.00
12.5.2.1 900 X 900mm (up to 1000mm depth) (MD Cover) Nos 3.00 0
TOTAL OF FIRE FIGHTING WORKS 0
13. ELECTRICAL WORK
13.1.00 HT CABLES & ACESSORIES
13.01.00 Supply of armoured aluminium conductor, XLPE insulated FRLS cables of following sizes with Cable labeling directly buried underground, laid in built-up trench / cable tray, pulled through embedded conduits / pipe sleeves, cleated to local support etc. including installation of G.I. clamps, cleats, spacers, hardware etc. Cable Trays, excavation & backfilling is included.
13.01.01 3 C x 240sq.mm 11 KV (E) AL XLPE FRLS cable Rmt 1,000.00 0
13.02.00 Supplying and making indoor cable end termination with heat shrinkable jointing kit complete with all accessories including lugs suitable for following size of 3 core, XLPE aluminium conductor cable of 11KV grade as required :
13.03.00 Supplying and making outdoor cable end termination with heat shrinkable jointing kit complete with all accessories including lugs suitable for following size of 3 core, XLPE aluminium conductor cable of 11KV grade as required :
13.04.00 Supplying and making straight through cable jointing with heat shrinkable jointing kit complete with all accessories including lugs suitable for following size of 3 core, XLPE aluminium conductor cable of 11KV grade as required :
13.05.00 Supply & installation of 100mm x 75mm oval caste iron cable route markers with 350mm MS Angle support of size 25 x 25 x 6mm / 20mm GI Pipe support in 150 x 150 x 150mm PCC block.
13.06.00 Supply, Installation, testing & commissioning of Compact HT-Panel 11KV 630A, 21KA Non-Extensible Compact Vacuum Circuit Breaker in SF6 insulated stainless steel enclosure type with built in control supply arrangement. Panel suitable for termination of power cables through rear bottom entry, cable gland plates and other accessories as per SEB specification. (as per the SLD and technical specifications.) Nos 1.00 0
13.07.00 Supply, Installation, testing & commissioning of Indoor type HT Breaker Panel 11KV 1 nos. 630A, 21KA Non-Extensible Compact Vacuum Circuit Breaker in SF6 Incomer + 2 nos. 630A, 21KA Non-Extensible Compact Vacuum Circuit Breaker in SF6 insulated stainless steel enclosure type with built in control supply arrangement consisting of a. EF / OC Series Relay as outgoing for Transformer feeders. Panel suitable for termination of power cables through rear bottom entry, cable gland plates and other accessories as per SEB specification for substation. (as per the SLD and technical specifications.) Nos 1.00 0
13.08.00 Supply Installation, site testing, commissioning of indoor type, Copper wound, 1600 KVA, 11KV/0.415 kV, Dyn11, Dry type Distribution Transformer with OLTC , Cable End Box on Primary/HV side & Secondary/LV side for termination as per data sheet. Transformer should be manufactured as per I.S. standards (is 2026 part-1 2012, Losses shall be as per latest ECBC norms and Tech. specifications and Data sheet attached. Note: Unloading at site is also included in scope. Note: Control cables from transformer to panel is included in this scope and cables are mentioned separately in cables item. Nos 2.00 0
13.09 Construction of cable chambers with complete supply of brics masonry, chamber covers & other accessories.
Earthing + Lightning protection system
13..10.00 Supplying, installation and testing of maintenance free earthing comprising of Electrode of 17.2 mm diameter Low Carbon Steel with 250 micron molecular copper bonded earthing rod of Length 3m along with 25kg Carbon based environment friendly back fill ground enhancing compound required to fill up the excavated earth with required quantity complete, and recording the results Specification no. EA-MOBI Nos 50.00 0
13.11.00 Supply, tagging, laying or fixing, testing of GI / CU earthing strip / wire in ground at a depth of 600mm including excavation in all type of strata except hard rock or in readymade trenches with necessary clamps, revette jointing as per specification complete as required. Brazed joints for Cu strips, Coating joints with bitumen paint etc. shall be considered. Welding of GI strip to be avoided.
13.11.01 75mm x 6mm thick GI strip. Rmt 50.00 0
13.11.02 50mm x 6mm thick GI strip. Rmt 750.00 0
13.11.03 32mm x 6mm thick GI strip. Rmt 650.00 0
13.11.04 25mm x 6 mm thick GI strip. Rmt 150.00 0
13.11.05 25mm x 3 mm thick GI strip. Rmt 250.00 0
13.11.06 25mm x 3 mm thick CU strip. Rmt 450.00 0
13.11.07 75mm x 6mm thick Cu strip. Rmt 10.00 0
13.11.08 32 mm x 6 mm thick. Cu strip. Rmt 50.00 0
13.11.09 25 mm x 6 mm thick. Cu strip. Rmt 20.00 0
13.11.10 25 mm x 3 mm thick. Cu strip. with green sleeve. Note: Strip required without sleeve if required shall be considered through this quantity only. Rmt 350.00 0
13.11.11 25mm x 3 mm Cu Strip down conductor mounted on porcelain insulator for Lightning Arrestor. Rmt 330.00 0
13.11.12 16 SWG GI wire. Rmt 50.00 0
13.11.13 14 SWG GI wire. Rmt 40.00 0
13.11.14 12 SWG GI wire. Rmt 350.00 0
13.11.15 8 SWG GI wire. Rmt 150.00 0
13.11.16 14 SWG Cu wire. Rmt 25.00 0
13.11.17 12 SWG Cu wire. Rmt 25.00 0
13.11.18 8 SWG Cu wire. Rmt 350.00 0
13.11.19 8 SWG Cu wire with green sleeves Rmt 10.00 0
13.11.20 1C x 50 Sq.mm. 2XFY cable Rmt 29.00 0
13.11.21 1C x 35 Sq.mm. 2XY cable Rmt 180.00 0
13.11.22 1C x 16 Sq.mm. 2XY cable Rmt 10.00 0
13.11.23 1C x 10 Sq.mm. 2XY cable Rmt 10.00 0
13.11.24 4.0 sq.mm. green Cu wire. Rmt 100.00 0
13.12.0 Supply and installation of earth busbar box consisting of 2 x 25 x 3 mm, 300mm long GI Strip with multiple tapping and nut bolt arrangements etc. mounted on SMC insulators. Box shall be fabricated from M.S. sheet including powder coated, clear acrylic hinged door etc. complete. Nos 15.00 0
13.13.0 Supply and installation of earth busbar box consisting of 2 x 50 x 6 mm, 300mm long GI. Strip with multiple tapping and nut bolt arrangements etc. mounted on SMC insulators. Box shall be fabricated from M.S. sheet including powder coated, clear acrylic hinged door etc. complete. Nos 10.00 0
13.13.01 AIR TERMINATION SYSTEM
13.14 Supply of 8mm dia Aluminium alloy Solid Round Conductor of material AlMgSi used in air termination system . Cross sectional area of conductor should be 50 mm². Rmt 1,520.00 0
13.15.0 Supply of Nylon Conductor Holder for Parapet wall for holding 8 mm dia Aluminium alloy round Conductor. Nos 1,435.00 0
13.16.0 Supply of Nylon roof conductor holder for flat roof with concrete block for fixing 8 mm dia Aluminium alloy Solid Round Conductor in the terrace flat surface at every 1 mtr. Nos 270.00 0
13.17.0 Supply of Stainless steel SS / AL 304 Grade Metal roof conductor holder with bottom plate to fix the 8-10 mm dia Aluminium alloy Solid Round Conductor for horizontal air terminal above metal sheet to meet the requirements as per IS/IEC 62305 and IEC 62561-4. Nos 190.00 0
13.18.0 Supply of Adhesion Glue for fixing metal roof conducter holder over the metal surface to meet the requirment of IS/IEC - 62305. Nos 3.00 0
13.19.0 Supply of Stainless steel 304 Grade Cross Connector for 8 mm dia Aluminium alloy round conductor & 10 mm Copper bonded conductor at cross/Tee junction. Nos 141.00 0
13.20.0 Supply of Expansion Joint with connector to compensate the expansion and contraction of Solid Round Al. Conductor during temperature variations. Expansion Joint should be consider at every 20 mtr length of straight horizontal air termination and connected at both the end with use of straight connector conductor. Nos 76.00 0
13.21.0 Supply of Aluminium Straight conductor connector for interconnecting 8mm Aluminium conductor to meets the requirement of IS/IEC 62305. Nos 51.00 0
13.22.0 Supply of air termination rod of 3mtr length of material AlMgSi of diametre ø 16/10 mm crimped on both the ends (Tappered Type). The rod shall be mounted with stainless steel clamp and fixing accessories Nos 11.00 0
13.23.0 Supply of air termination rod of 3 mtr length of material AlMgSi of diametre ø 16/10 mm crimped on both the ends(Tappered Type). The rod shall be mounted with stone and fixing accessories . Test Parameter for 3 mtr vertical air terminal a)ELectrical Resistivity Nos 9.00 0
13.24.0 Supply of stainless steel Earth stud of dimension 69 x 69 mm integrated inside concrete and should be tested for electrical resistivity, salt spray and humidity test & short circuit to meet the requirements of IS/IEC 62305 and IEC 62561-1&2. (for interconnecting Air termination and structral down conductors) Nos 33.00 0
13.25.0 Supply of connecting point made of stainless steel for terminating 10mm copper conductor. Nos 33.00 0
13.26.0 Supply of Aluminuim folding seam conductor holder as per sheet profile for an 8 mm dia aluminium alloy solid round conductor for fixing a horizontal air terminal above the metal sheet to meet the requirements for IS/IEC 62305 and tested as per IEC 62561-4. Nos 15.00 0
STRUCTURAL RISER
13.27.0 Supply of 10 mm copper bonded Solid Steel Round Conductor with average coating thickness minimum of 100µm for Type-B Earthing and should be tested for Tensile strength, Electrical Resistance, salt mist, Bend & Adhesion to meet the requirements of IS/ IEC 62305 and IEC 62561-1&2. Rmt 940.00 0
13.28.0 Supply of Bonding clamp for interconnecting 10 mm Round Conductor with reinforcement rebar at every 3.5Mtr inside the concrete to meet the requirements of IS/IEC 62305. Nos 320.00 0
13.29.0 Supply of stainless steel Straight Connector at every 3Mtr of integrated down conductor and should be tested for electrical resistivity, mechanical load to meet the requirement for IS/IEC - 62305 and IEC 62561-1&2. CAPE Type: SC 8-10 (Article No. 400 210) Nos 190.00 0
13.30.0 Supply of stainless steel Earth stud of dimension 69 x 69 mm integrated inside concrete and should be tested for electrical resistivity, salt spray and humidity test & short circuit to meet the requirements of IS/IEC 62305 and IEC 62561-1&2. Nos 33.00 0
STRUCTURAL FOUNDATION EARTHING
13.31.0 Supply of 10 mm copper bonded Solid Steel Round Conductor with average coating thickness minimum of 70µm for Type-B Earthing and should be tested for Tensile strength, Electrical Resistance, salt mist, Bend & Adhesion to meet the requirements of IS/ IEC 62305 and IEC 62561-1&2. Rmt 925.00 0
13.31.01 Installation of Exothermic Welding - Including welding mould and other accessories for welding confirms the requirements of IEEE 837:2014 : T-Joint, X-Joint, L-Joint , Straight joint Nos 72.00 0
13.32.0 Supply of Corrosion Bitumen tape for inside soil. Nos 8.00 0
L. T. Panels and Distribution Board
13.33 Supply,Unloading, installation, testing & commissioning of MV panel boards compartmental cubicle type freestanding with appropriate cable entries, front operating, front maintained wherever required complete with base frame etc. as required and as per IS 8623/ IEC 61439, Technical specifications & Single line diagram. (Refer Single Line Diagram of Respective Building for Switchgear and other details). Panels shall be as per IEC 61439, fabricated out of 14 / 16 SWG CRCA sheet, and surface treated with phosphating seven tank process and duly powder coated with RAL 7035. Panel vendor shall be CPRI approved manufacturer & shall comply panels as per technical specifications.
13.33.01 Main LT panel ( with Gas flooding system as per specs.) Nos 1.00 0
13.33.02 UPS INPUT PANEL(as per SLD) Nos 1.00 0
13.33.03 UPS OUTPUT PANEL(as per SLD) Nos 1.00 0
13.33.04 EMERGENCY PANEL(as per SLD) Nos 1.00 0
13.33.05 MAIN BUILDING UPS PDB(as per SLD) Nos 1.00 0
13.33.06 SOUTH BLOCK UPS PDB(as per SLD) Nos 1.00 0
13.33.07 NORTH BLOCK UPS PDB(as per SLD) Nos 1.00 0
13.33.08 PUMP ROOM PANEL(as per SLD) Nos 1.00 0
13.33.09 UTILITY PANEL(as per SLD) Nos 1.00 0
13.33.10 TERRACE ROOM PANEL(as per SLD) Nos 1.00 0
13.33.11 LIFT & ESCALATOR PANEL-01(as per SLD) Nos 1.00 0
13.33.12 LIFT & ESCALATOR PANEL -02(as per SLD) Nos 1.00 0
13.33.13 NORTH BLOCK MAIN PANEL(as per SLD) Nos 1.00 0
13.33.14 SOUTH BLOCK MAIN PANEL(as per SLD) Nos 1.00 0
13.33.15 MAIN BLOCK MAIN PANEL(as per SLD) Nos 1.00 0
13.33.16 FF C/O FLOOR PANEL(as per SLD) Nos 1.00 0
13.33.17 450 kVAr RTPFC- Hybrid Panel with 7% detuned and active filter at 415V as per SLD. Nos 2.00 0
13.33.18 LG MAIN FLOOR DB-01(as per SLD) Nos 1.00 0
13.33.19 LG MAIN UPS DB-01(as per SLD) Nos 1.00 0
13.33.20 LG MAIN FLOOR DB-02(as per SLD) Nos 1.00 0
13.33.21 LG MAIN UPS DB-02(as per SLD) Nos 1.00 0
13.33.22 LG MAIN FLOOR DB-03(as per SLD) Nos 1.00 0
13.33.23 LG MAIN UPS DB-03(as per SLD) Nos 1.00 0
13.33.24 MEZ MAIN FLOOR DB(as per SLD) Nos 1.00 0
13.33.25 MEZ UPS DB(as per SLD) Nos 1.00 0
13.33.26 GF MAIN FLOOR DB-01(as per SLD) Nos 1.00 0
13.33.27 GF MAIN UPS DB-01(as per SLD) Nos 1.00 0
13.33.28 KITCHEN MAIN PANEL(as per SLD) Nos 1.00 0
13.33.29 GF KITCHEN UPS DB(as per SLD) Nos 1.00 0
13.33.30 GF MAIN FLOOR DB-02(as per SLD) Nos 1.00 0
13.33.31 GF MAIN UPS DB-02(as per SLD) Nos 1.00 0
13.33.32 GF MAIN FLOOR DB-03(as per SLD) Nos 1.00 0
13.33.33 GF MAIN UPS DB-03(as per SLD) Nos 1.00 0
13.33.34 1F MAIN FLOOR DB-01(as per SLD) Nos 1.00 0
13.33.35 1F MAIN UPS DB-01(as per SLD) Nos 1.00 0
13.33.36 1F MAIN FLOOR DB-02(as per SLD) Nos 1.00 0
13.33.37 1F MAIN UPS DB-02(as per SLD) Nos 1.00 0
13.33.38 1F MAIN FLOOR DB-03(as per SLD) Nos 1.00 0
13.33.39 1F MAIN UPS DB-03(as per SLD) Nos 1.00 0
13.33.40 2F MAIN FLOOR DB-01(as per SLD) Nos 1.00 0
13.33.41 2F MAIN UPS DB-01(as per SLD) Nos 1.00 0
13.33.42 2F MAIN FLOOR DB-02(as per SLD) Nos 1.00 0
13.33.43 2F MAIN UPS DB-02(as per SLD) Nos 1.00 0
13.33.44 3F MAIN FLOOR DB(as per SLD) Nos 1.00 0
13.33.45 3F MAIN UPS DB(as per SLD) Nos 1.00 0
13.33.46 4F MAIN FLOOR DB(as per SLD) Nos 1.00 0
13.33.47 4F MAIN UPS DB(as per SLD) Nos 1.00 0
13.34.0 Supply, installation, testing, tagging, (Circuit numbering) and commissioning of following double door readymade recessed type MCB, DB, fabricated out of CRCA sheet and painted with powder coating process OR made out of scratch proof polycarbonate body and concealed in wall, or on surface or on steel column with necessary mounting frame complete as required along with gland covers at both ends (IP42 min) Si RCCB - Indicates RCCB with enhanced immunity to unwanted tripping under harmonics presence.
13.34.01 04 Way VTPN DB with 63A FP RCBO,100mA as incomer, and 1no.of O/G 10A SP MCB, 2no.of O/G 20A SP MCB, 3no.of O/G 32A TP MCB. as outgoing as per SLD. Nos 1.00 0
13.34.02 06 Way VTPN DB with 63A FP RCBO,100mA as incomer and 3no.of O/G 10A SP MCB, 3no.of O/G 20A SP MCB, 4no.of O/G 32A TP MCB. as outgoing as per SLD. Nos 1.00 0
13.34.03 12 Way SPN DB with 25A DP RCBO,30mA as incomer and 10no.of O/G 10A SP MCB. as outgoing as per SLD. Nos 2.00 0
13.34.04 12 Way SPN DB with 40A DP RCBO,30mA ,Si as incomer and 10no.of O/G 20A SP MCB. as outgoing as per SLD. Nos 1.00 0
13.34.05 12 Way SPN DB with 40A DP RCBO,30mA as incomer and 10no.of O/G 10A SP MCB . as outgoing as per SLD. Nos 1.00 0
13.34.06 12 Way SPN DB with 40A DP RCBO,30mA as incomer and 1no.of O/G 10A SP MCB ,9no.of O/G 20A SP MCB. as outgoing as per SLD. Nos 3.00 0
13.34.07 12 Way SPN DB with 40A DP RCBO,30mA as incomer and 8no.of O/G 10A SP MCB ,2no.of O/G 20A SP MCB. as outgoing as per SLD. Nos 1.00 0
13.34.08 12 Way SPN DB with 40A DP RCBO,30mA as incomer and 10no.of O/G 20A SP MCB. as outgoing as per SLD. Nos 3.00 0
13.34.09 12 Way SPN DB with 40A DP RCCB,30mA,Si as incomer and 1no.of O/G 10A SP MCB, 9no.of O/G 20A SP MCB. as outgoing as per SLD. Nos 1.00 0
13.34.10 12 Way TPN DB with 25A FP RCBO,30mA as incomer and 36no.of O/G 10A SP MCB. as outgoing as per SLD. Nos 1.00 0
13.34.11 12 Way TPN DB with 25A FP RCBO,30mA as incomer and 36no.of O/G 20A SP MCB. as outgoing as per SLD. Nos 1.00 0
13.34.12 12 Way TPN DB with 40A FP RCBO,100mA as incomer and 36no.of O/G 20A SP MCB. as outgoing as per SLD. Nos 1.00 0
13.34.13 12 Way TPN DB with 63A FP RCBO,30mA as incomer and 36no.of O/G 20A SP MCB. as outgoing as per SLD. Nos 1.00 0
13.34.14 12 Way VTPN DB with 63A FP RCBO,100mA as incomer, and 8no.of O/G 10A SP MCB, 7no.of O/G 20A SP MCB, 7no.of O/G 32A TP MCB. as outgoing as per SLD. Nos 1.00 0
13.34.15 4 Way SPN DB with 25A DP RCBO,30mA as incomer and 2no.of O/G 20A SP MCB. as outgoing as per SLD. Nos 3.00 0
13.34.16 4 Way TPN DB with 25A FP RCBO,30mA as incomer and 12no.of O/G 10A SP MCB. as outgoing as per SLD. Nos 2.00 0
13.34.17 4 Way TPN DB with 40A FP RCBO,30mA as incomer and 12no.of O/G 20A SP MCB. as outgoing as per SLD. Nos 1.00 0
13.34.18 4Way TPN DB with 40A FP RCBO,30mA as incomer and 5no.of O/G 10A SP MCB ,7no.of O/G 20A SP MCB. as outgoing as per SLD. Nos 1.00 0
13.34.19 6 Way TPN Per Phase Isolation DB with 40A TP MCB as incomer,and 40A DP RCBO as 30mA ,SI 3no.subincomer for Phase segregation and 8no.of O/G 10A SP MCB, 4no.of O/G 20A SP MCB Nos 1.00 0
13.34.20 6 Way TPN DB with 25A FP RCBO,30mA as incomer and 18no.of O/G 10A SP MCB. as outgoing as per SLD. Nos 1.00 0
13.34.21 6 Way TPN DB with 40A FP RCBO,30mA as incomer and 18no.of O/G 20A SP MCB. as outgoing as per SLD. Nos 1.00 0
13.34.22 6 Way TPN DB with 40A FP RCBO,30mA as incomer and 12no.of O/G 10A SP MCB, 6no.of O/G 20A SP MCB. as outgoing as per SLD. Nos 1.00 0
13.34.23 8 Way SPN DB with 25A DP RCBO,30mA as incomer and 2no.of O/G 10A SP MCB, 2no.of O/G 20A SP MCB. as outgoing as per SLD. Nos 1.00 0
13.34.24 8 Way SPN DB with 25A DP RCBO,30mA as incomer and 6no.of O/G 10A SP MCB. as outgoing as per SLD. Nos 8.00 0
13.34.25 8 Way SPN DB with 25A DP RCCB,30mA,Si as incomer and 3no.of O/G 10A SP MCB,3no.of O/G 20A SP MCB. as outgoing as per SLD. Nos 1.00 0
13.34.26 8 Way SPN DB with 40A DP RCBO,30mA as incomer and 6no.of O/G 20A SP MCB. as outgoing as per SLD. Nos 18.00 0
13.34.27 8 Way SPN DB with 40A DP RCBO,30mA as incomer and 1no.of O/G 10A SP MCB, 5no.of O/G 20A SP MCB. as outgoing as per SLD. Nos 8.00 0
13.34.28 8 Way SPN DB with 40A DP RCBO,30mA as incomer and 4no.of O/G 10A SP MCB, 2no.of O/G 20A SP MCB. as outgoing as per SLD. Nos 1.00 0
13.34.29 8 Way SPN DB with 40A DP RCBO,30mA,Si as incomer and 1no.of O/G 10A SP MCB, 3no.of O/G 20A SP MCB, 2no.of O/G 25A SP MCB. as outgoing as per SLD. Nos 1.00 0
13.34.30 8 Way SPN DB with 40A DP RCCB,30mA,Si as incomer and 2no.of O/G 10A SP MCB,4no.of O/G 20A SP MCB. as outgoing as per SLD. Nos 1.00 0
13.34.31 8 Way SPN DB with 40A DP RCCB,30mA,Si as incomer and 6no.of O/G 20A SP MCB. as outgoing as per SLD. Nos 2.00 0
13.34.32 8 Way TPN DB with 25A FP RCBO,30mA as incomer and 24no.of O/G 10A SP MCB. as outgoing as per SLD. Nos 4.00 0
13.34.33 8 Way TPN DB with 40A FP RCBO,30mA as incomer and 24no.of O/G 20A SP MCB. as outgoing as per SLD. Nos 1.00 0
13.34.34 8 Way TPN DB with 40A FP RCBO,30mA as incomer and 18no.of O/G 10A SP MCB, 6no.of O/G 20A SP MCB. as outgoing as per SLD. Nos 1.00 0
13.35.0 Supply, fixing, testing, of good quality industrial sockets with MCB's or MCB isolators of different ratings in readymade IP 42/44 Polycabonate unbreakable enclosure. Box should be suitable to terminate cables / wires easily, complete as required.
13.35.01 16A 1Ø, 3 Pin Socket and plug with 16A SP MCB in a Readymade Box. Nos 20.00 0
13.35.02 32A 3Ø, 5 Pin Socket and plug with 32A FP RCBO in a Readymade Box. Nos 20.00 0
13.35.03 32A 1Ø, 3 Pin Socket and plug with 32A DP RCBO in a Readymade Box. Nos 1.00 0
13.35.04 16A 1Ø, 3 Pin Socket and plug with 16A DP RCBO in a Readymade Box. Nos 1.00 0
13.35.05 16A 3Ø,3 Pin Socket and plug 16A SP MCB + 32A 3Ø, 5 Pin Socket and plug 32A TP MCB in a Readymade Box. Nos 1.00 0
13.35.06 63A 3Ø, 5 Pin Socket and plug with 63A TP MCB in a Readymade Box. Nos 1.00 0
13.35.07 16 A DP MCB in a Readymade enclosure with cable end box for incoming & outgoing cable. Nos 1.00 0
13.35.08 32 A FP MCB in a Readymade enclosure with cable end box for incoming & outgoing cable. Nos 1.00 0
13.35.09 40 A FP MCB in a Readymade enclosure with cable end box for incoming & outgoing cable. Nos 3.00 0
13.35.10 63 A FP MCCB in a Readymade enclosure with cable end box for incoming & outgoing cable. Nos 2.00 0
13.35.11 100 A FP MCCB in a Readymade enclosure with cable end box for incoming & outgoing cable. Nos 5.00 0
13.35.12 125 A FP MCCB in a Readymade enclosure with cable end box for incoming & outgoing cable. Nos 2.00 0
13.35.13 160 A FP MCCB in a Readymade enclosure with cable end box for incoming & outgoing cable. Nos 3.00 0
13.35.14 200 A FP MCCB in a Readymade enclosure with cable end box for incoming & outgoing cable. Nos 1.00 0
13.35.15 250 A FP MCCB in a Readymade enclosure with cable end box for incoming & outgoing cable. Nos 1.00 0
13.35.16 63 A DP MCB in a Readymade enclosure with cable end box for incoming & outgoing cable. Nos 1.00 0
13.35.17 DOL starter suitable for 5 - 7.5 Hp motors. Nos 1.00 0
13.36.0 Supply, installation, testing of set of Bulkhead fixture with 9 W LED or wattage as per lift vendor and 1 No. 5A, 3 pin socket + switch on common good quality board in lift pit. Nos 61.00 0
13.37.0 Supply, fixing, testing, of good quality industrial interlocked switched sockets with MCB's of different ratings in readymade IP 65 Polycabonate unbreakable enclosure. Box should be suitable to terminate cables / wires easily, complete as required.
13.37.01 20A 1Ø, 3Pin Socket and plug with 20A SP MCB in a Readymade Box. Nos 2.00 0
13.37.02 63 A 4 Pole RCCB 100mA + 10A DP MCB in single readymade box for lift machine room. Nos 15.00 0
13.37.03 32A 1Ø, 3 Pin Industrial Socket and plug with 32A DP RCBO in a Readymade Box, on RAW. Nos 2.00 0
13.37.04 16A 1Ø, 3 Pin Industrial Socket and plug with 16A SP MCB in a Readymade Box, on UPS. Nos 1.00 0
13.37.05 16A 1Ø, 3 Pin Industrial Socket and plug with 16A SP MCB in IP65 Readymade Box with Enclosure for EV Car Charging; on RAW Nos 10.00 0
13.37.06 16A 1Ø, 3 Pin Industrial Socket with 16A SP MCB+ 32A 1Ø, 3 Pin Industrial Socket with 32A TP MCB in IP65 Readymade Box with Enclosure for EV Car Charging; on RAW. Nos 10.00 0
13.37.07 40A 3Ø, Industrial Socket with 63A FP RCBO,30mA in a Readymade Box, on RAW. Nos 4.00 0
13.37.08 63A 3Ø, Industrial Socket with 63A FP RCBO,30mA in a Readymade Box, on RAW. Nos 1.00 0
MV CABLE JOINTING & END TERMINATION
13.38.00 Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.
13.38.01 1 X 35 sq. mm (Unarm.) Nos 8.00 0
MV CABLES & ACCESSORIES
13.39.0 Supply of following LT cables rated for 1100 volts AC as per IS 7098- part 1 of 1998 / IEC 60502 necessary G.I clamps. All the cables shall have FRLSH property also properly clamped or tied when run on cable trays. All such cables shall be provided with temporary labeling at every 20 mtrs and then finally with metal identification tags showing the size and the location from/to the specific Panel/DB at both ends.
Note: Cost Includes following Items : 1) Delivery of the cables at site. 2) Unloading at site store and shifting from store to site where it shall be installed. 3) Laying of cable in the prepared trench / cable tray / duct when laid inside the building or underground when laid outside the building. 4) Excavation in hard or soft murrem / rocky area upto required depth, supply and laying of protection bricks, supply and backfilling with fine sand, leveling the ground to match with the existing condition (As per site condition or as per client requirement).
13.40.0 Supply, testing, tagging, laying and commissioning following sizes of 1100 Volt grade, XLPE / FRLS insulated multistrand Al. / Cu. Conductor armoured / unarmoured Fire Survival Armoured Cables (As Per BS 8434-2 & BS 6387 CWZ) in readymade RCC trench, in provided PVC pipe, RCC pipe hume pipe, on cable trays / ladders etc. as. required complete with clamps for fixing tagging etc.(MLTP TO Main Em. Panel & FF C/O Panel, SYNC. PANEL TO Main EM. Panel)
13.40.01 3.5Cx300 Sq.mm. A2XFY Cable (FS) Rmt 500.00 0
13.41.0 End termination for above Fire Survival Armoured Cables including glands Brass heavy duty, lugs, consumable etc. (End terminations for flexible cables will not be considered separately). (MLTP TO Main Em. Panel & FF C/O Panel, SYNC. PANEL TO Main EM. Panel)
13.41.01 3.5Cx300 Sq.mm. A2XFY Cable (FS) Nos 30.00 0
13.42.0 Supply & installation of readymade hot dip GI. Ladder type tray, shall have 100/ 75/50mm "C" shape channel and rungs at 200 mm CC including readymade accessories e.g. vertical & horizontal bends, Tee's, rightangles, reducers, risers, coupler plates etc. Note: All cable trays shall be powder coated with black color.
13.42.01 1000 x 100 mm ladder tray 14 SWG. Rmt 50.00 0
13.42.02 750 x 75 mm ladder tray 14 SWG. Rmt 80.00 0
13.42.03 600 x 75 mm ladder tray 14 SWG. Rmt 25.00 0
13.42.04 450 x 50 mm ladder tray 14 SWG. Rmt 10.00 0
13.43.00 Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray (Galvanisation thickness not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required.
13.43.01 50 mm width X 50 mm depth X 1.6 mm thickness Rmt 10.00 0
13.43.02 100 mm width X 50 mm depth X 1.6 mm thickness Rmt 150.00 0
13.43.03 150 mm width X 50 mm depth X 1.6 mm thickness Rmt 10.00 0
13.43.04 200 mm width X 50 mm depth X 1.6 mm thickness Rmt 350.00 0
13.43.05 300 mm width X 50 mm depth X 1.6 mm thickness Rmt 350.00 0
13.43.06 450 mm width X 50 mm depth X 2.0 mm thickness Rmt 75.00 0
13.43.07 600 mm width X 50 mm depth X 2.0 mm thickness Rmt 300.00 0
13.44.00 Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray "bends" (galvanisation not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required.
13.44.01 50 mm width X 50 mm depth X 1.6 mm thickness Nos 5.00 0
13.44.02 100 mm width X 50 mm depth X 1.6 mm thickness Nos 40.00 0
13.44.03 150 mm width X 50 mm depth X 1.6 mm thickness Nos 5.00 0
13.44.04 200 mm width X 50 mm depth X 1.6 mm thickness Nos 50.00 0
13.44.05 300 mm width X 50 mm depth X 1.6 mm thickness Nos 50.00 0
13.44.06 450 mm width X 50 mm depth X 2.0 mm thickness Nos 15.00 0
13.44.07 600 mm width X 50 mm depth X 2.0 mm thickness Nos 40.00 0
13.45.01 Supply and fabrication of M.S. angle / channel supports for wall mounting DB/panels, frames, steel support over trench etc. including necessary painting with 2 coats of primer & 2 coats of enamel paint, & required hardware for fixing of supports etc. complete. Kg 5,000.00 0
13.46.00 Supply and installation of readymade GI Trunking Without Cover of following size with 50 mm depth unless otherwise specified including readymade accessories e.g. Vertical, horizontal bends, tee's, rightangles, reducers, risers, coupler plates etc. Not: Trunking shall be powder coated. It is to be used for DB cluster for cable/wire management and as per architects requirement wherever required.
13.46.01 50 mm GI Trunking Without Cover 16 SWG. Rmt 50.00 0
13.46.02 100 mm GI Trunking Without Cover 16 SWG. Rmt 300.00 0
13.47.00 Engineering, Shop drawing, Supply, installation, testing & commissioning of following size Aluminium Conductor, 3Ph+N, (including external earthing conductors) Sandwitch busducts including necessary accessories like Bends, Elbows, Flanged ends, expansion joint, Tinned Cu flexible connection links at ends of Trafo, MLTP,DG syc panel etc. busbar support(if any), hardware for interconnection, necessary supports, clamps etc. complete. as per specs & actual site requirement.
13.47.01 2500A TPN, AL Sandwitch Busduct (50kA) Rmt 75.00 0
13.47.02 630A TPN, AL Sandwitch Busduct (50kA) Rmt 10.00 0
13.47.03 2500A PH. Crossover box arrangement suitable for above Busduct. (1 Nos / set of busduct) Set 4.00 0
13.47.04 2500A Cu. Flexible end connection set suitable for above Busduct. (2 Nos / set of busduct) Set 8.00 0
13.47.05 630A PH. Crossover box arrangement suitable for above Busduct. (1 Nos / set of busduct) Set 1.00 0
13.47.06 630A Cu. Flexible end connection set suitable for above Busduct. (2 Nos / set of busduct) Set 2.00 0
POINT WIRING, FIXTURES
13.48.00 Supply, installation of point wiring for light, 5A socket points in surface 25 mm dia, 2mm thick FRLS conduits with 2 x 2.5 + 1 x 2.5 Sq.mm LSZH insulated multistrand Cu. conductor wire as sub mains & 2 x 2.5 + 1 x 2.5 Sq.mm. LSZH Insulated multistand Cu. conductor wire for point wiring with 6 Amp SP modular switch fixed on modular switch board in wall, including fancy angle holder / ceiling rose etc. complete as required (submain will not be measured separately). Note:-point wiring is inclusive of back box , modular plate, switches/socket with all required accessories
13.48.01 Light Point wiring for light points with necessary 6A modular switch, ceiling rose compete (.point wiring is inclusive of back box , modular plate, switches/socket) point 106.00 0
13.48.02 Point wiring as above with 2 x 2.5 + 1 x 2.5 Sq.mm. Cu. wire in suitable size FR PVC conduit for Emergency Light Points with controlled from 6A modular switches in Cabins, rooms. (point wiring is inclusive of back box , modular plate, switches/socket) point 32.00 0
13.48.03 As Above but Point wiring for light points with ceiling rose Controlled with MCB (Switching will be from respective lighting DB)(.point wiring is inclusive of back box , modular plate) point 1,800.00 0
13.48.04 As Above but Point wiring for Emergency light points with ceiling rose Controlled with MCB (Switching will be from respective lighting DB).(.point wiring is inclusive of back box , modular plate) point 200.00 0
13.48.05 Point wiring as above using 2 x 4 + 1 x 2.5 Sq.mm. in suitable FRPVC conduit including 1 Nos. modular 6A/16A Switch & Socket with Modular plate, box at one place for utility & printer points fresh / Ex air air fan Points) connections. On raw power (.point wiring is inclusive of back box , modular plate, switches/socket) point 300.00 0
13.48.06 Point wiring as above using 2 x 2.5 + 1 x 2.5 Sq.mm. in suitable FRPVC conduit including 1 Nos. modular 6A/16A Switch & Socket with Modular plate, box at one place for utility & printer points fresh / Ex air air fan Points) connections. On raw power (.point wiring is inclusive of back box , modular plate, switches/socket) point 100.00 0
13.48.07 2 No. 6/16A Socket on UPS Below Table + 1 No.16A Switch Above Table & 1 No. 6/16 Socket with Switch on Raw Above Table suitable to fit in selected workstation table.(co-ordinate with workstation table vendor for exact positioning) (.point wiring is inclusive of back box , modular plate, switches/socket) point 55.00 0
13.48.08 6A 3 pin socket outlets independent (Modular). (.point wiring is inclusive of back box , modular plate, switches/socket) point 30.00 0
13.48.09 6A 3 pin socket outlets on board (Modular). (.point wiring is inclusive of back box , modular plate, switches/socket) point 155.00 0
13.48.10 6/16A 5 pin socket outlets on board (Modular). (.point wiring is inclusive of back box , modular plate, switches/socket) point 1.00 0
13.49.0 Supply & Installation of mains 2 x 2.5 + 1 x 2.5 sq.mm. Cu. multistrand ZHLS Cu. wires 1100 V gr. in dia. 25mm size, 16 SWG GI ERW conduits complete. Rmt 100.00 0
13.50.0 Supply & Installation of mains 2 x 4.0 + 1 x 2.5 sq.mm. Cu. multistrand ZHLS Cu. wires 1100 V gr. in dia. 25mm size, 16 SWG GI ERW conduits complete. Rmt 100.00 0
13.51.0 Supply & Installation of GI ERW conduit with accessories of following sizes with spacer saddles for open or in slab.
13.52.00 Supply,Installation, testing & commissioning of lighting fixtures supplied by vendor with required with suitable control gear, electronic control gear for fluorescent) material including necessary accessories, wiring connection, junction boxes, chain, down drops, supports etc. Scope also includes assembling of trunking fixture or any other type of fixture. Note- Unloading & storage of fixtures are including in scope. The wattage of fixture subject to vary as per lighting vendor design. However, the item for installation will not change. The areas are mentioned in the drawing where the fixtures are to be installed in the individual items. Refer layout for the type of fixture on drawing shared. Relate the drawing with ealier floors and quote accordingly. Any descripancy in consideration please highlight during quoting only.
13.52.01 RECESS MOUNTED 2'x2'LED PANEL, 36W Nos 800.00 0
13.52.02 9W LED DOWNLIGHTER Nos 10.00 0
13.52.03 18W LED DOWNLIGHTER Nos 20.00 0
13.52.04 20W LED BATTEN INDUSTRIAL RAIL Nos 120.00 0
13.52.05 40W LED BATTEN INDUSTRIAL RAIL Nos 275.00 0
13.53.00 Supply, installation, testing & commissioning of indoor recess mounted Different Type of Emergency Exit Signs(all directions) with min. one hour backup with all suitable mounting accessories etc. including wiring connection, two side viewing lamp,supports as required etc. complete. Note :This item & actual qty.shall be procured only after confirmation from Architects/client.
13.54.00 Supply, installation, testing & commissioning of 1200 mm sweep ceiling fan & 600-1000 mm down rod with canopies. Nos 5.00 0
13.55.00 Supply, installation, testing & commissioning of 900 mm sweep ceiling fan & 600-1000 mm down rod with canopies. Nos 1.00 0
13.56.00 Supply, installation, testing & commissioning of 250mm exhaust fan with frame & bird protection louvers including all hardware etc. complete as required. Nos 20.00 0
13.59.0 Supply,Installation, testing & commissioning of 3Phase Input & 3Phase Output UPS with 15/30 minutes Battery back up and sealed maintenance free lead acid maintained in battery racks complete with interconnections, Cu battery cables, Battery breakers. The rack shall be sturdy M.S. section fabricated with powder coating The scope shall include terminals & busbar shrouding for Battery terminals & connections. (Note:- Battery store shall start 150mm above FFL.) NOTE: The UPS configuration is as per SLD.
13.59.01 1 No. x200KVA UPS arrangement as per given specifications and details. Nos 4.00 0
13.59.02 1 No. x30KVA UPS arrangement as per given specifications and details. Nos 2.00 0
13.60.00 Supply, Installation of Sealed maintenance free valve regulated lead acid (VRLA) Battery (with reverse polarity protection MCCB) as per specifications complete suitable for following UPS sizes (Bidder should furnish the battery calculations for 15/30 minutes backup along with the BOQ). Note: The scope also includes complete SITC of cables, DCDBs, DC MCBs, required for battery interconnection as well as interconnections betwwen batteries and UPS with required all accessories.
13.60.01 200 KVA UPS (30 minutes). Set 4.00 0
13.60.02 30 KVA UPS (30 minutes). Set 2.00 0
13.61.00 Installation of battery rack floor mounting as per specifications with necessary fabrication complete for following sizes.
13.61.01 200 KVA UPS (30 minutes). Set 4.00 0
13.61.02 30 KVA UPS (30 minutes). Set 2.00 0
Raceway & Junction Box
13.62.00 Supply and installation of 2 mm thickness Aluminium extruded raceway for under floor installation including necessary cutting of floor providing couplers and clamps for raceway fixing as details provided making good the surface of floor complete as per sizes provided.
13.62.01 100mm x 38 mm deep AL. raceways. Rmt 130.00 0
13.62.02 150mm x 38 mm deep AL. raceways. Rmt 10.00 0
13.63.00 Supply and installation of readymade good quality floor junction boxes of appropriate sizes for raceways with folded frames including counter sunk screw arrangements such that Stainless Steel covers are in level with the floor level. The cover will be Stainless Steel & have 4 Nos. 25 / 32 mm Ø holes with rubber grommets at appropriate location.
13.63.01 150mm X 150mm deep X 50 16SWG junction box with 14 SWG cover. Nos 25.00 0
13.63.02 250mm X 250mm deep X 50 16SWG junction box with 14 SWG cover. Nos 8.00 0
13.63.03 350mm X 350mm deep X 50 16SWG junction box with 14 SWG cover. Nos 1.00 0
13.64.00 Supply & laying of 2mm thick blank FRPVC / GI. conduits of following sizes in floor or in slab including all accessories, deep junction box bends etc.
13.64.01 32mm dia FRPVC conduit Rmt 70.00 0
13.64.02 25mm dia FRPVC conduit. (Conduits in flooring) Rmt 150.00 0
13.64.03 25mm dia GI conduit. (Conduits in flooring) Rmt 20.00 0
EXTERNAL LANDSCAPE
13.65.00 Supply, testing, tagging, laying & commissioning following sizes of 1100 Volt grade, XLPE / PVC insulated multistrand AL/Cu. Conductor armoured / unarmoured cables (As Per IS 1554 & IS 7098) in readymade RCC trench, in PVC pipe, full round RCC hume pipe, on cable trays / ladders etc. as. required complete with clamps for fixing tagging etc.
13.65.01 4Cx4Sqmm 2XWY Cu. Cable complete. Rmt 50.00 0
13.65.02 4Cx2.5Sqmm 2XWY Cu. Cable complete. Rmt 50.00 0
13.65.03 3Cx2.5Sqmm 2XWY Cu. Cable complete. Rmt 50.00 0
13.66.00 End termination for above cables including Double Compression glands Brass heavy duty, Cu lugs, consumable etc. (End terminations for flexible cables will not be considered separately).
13.66.01 4Cx4Sqmm 2XWY Cu. Cable compete. Nos 10.00 0
13.66.02 4Cx2.5Sqmm 2XWY Cu. Cable compete. Nos 10.00 0
13.66.03 3Cx2.5Sqmm 2XWY Cu. Cable compete. Nos 10.00 0
13.67.00 Providing & fixing of Readymade Polycorbonate unbreakable Junction box with 15A, 4way connectors and knowout for 4 cable entry of following size.
13.67.03 150 x 150 x 50mm junction boxes as above but wheatherproof type (IP65) Nos 6.00 0
13.68.00 Supply,Installation, testing, tagging, (Circuit numbering) and commissioning of following double door ready - made recessed type MCB, DB, fabricated out of CRCA sheet and painted with powder coating process OR made out of scratch proof polycarbonate body, and concealed in wall, or on surface with necessary frame complete as required.
13.68.01 External Lighting DB Nos 2.00 0
13.69.00 Supply, Installation, testing and commissioning of 6.0 mtr.(6 mtr above ground) octagonal/conical/rectangular poles (as per supply form clien) with inbuilt cable loop box equivalent to SP-22 but with base plate suitable for mounting on concrete foundation. Scope includes 2 Nos. 40 mm dia PVC Sleeves bent to shape in foundation for cable entry, 16A 4 way connector, 16A SP MCB,earthing of pole with 8 SWG wire, required accessories & hardware, painting with 2 coats of primer & 2 coats of paint of approved shed. Note: Pole Foundation is not in Electrical Contractor scope.
13.69.01 Poles with single bracket Nos 4.00 0
13.69.02 Poles as above but with Double bracket Nos 8.00 0
13.70.00 Installation, testing & commissioning of street / flood light fixture on above poles with necessary controlgear, lamp, hardware etc. including cable connections from junction box.
13.70.01 80W LED weatherproof (IP65/66) Street light luminaire on above 6 mtr. height pole complete. Nos 4.00 0
13.70.02 20W LED weatherproof (IP65/66) Up lighter luminaire. Nos 2.00 0
13.70.03 15/20W Wall bracket/ Up down light LED weatherproof (IP65/66)Up lighter luminaire. Nos 6.00 0
13.70.04 50W Flood light LED weatherproof (IP65/66)Up lighter luminaire. Nos 4.00 0
13.70.05 20W LED weatherproof (IP65/66) Bollard light luminaire on above 1 mtr. height pole complete. Nos 8.00 0
13.70.06 10W LED weatherproof (IP65/66)Up lighter luminaire. Nos 4.00 0
Miscellaneous Items
13.71.00 Supply, installation of material equipment required as per statutorial provision & safety.
13.71.01 1.1 kV class Handgloves pair. Set 2.00 0
13.71.02 Laminated First aid chart with frame. Nos 4.00 0
13.71.03 First aid box. Nos 2.00 0
13.71.04 3 Nos. of Fire buckets with stand having weather shed canopy above the buckets with duly filled coarse sand and "FIRE" wriiten in English & "AAG" written in local (devnagari) language. Set 3.00 0
13.71.05 4.5 Kg. Co2 fire extinguisher mounted on wall. The Co2 Cylinder should be seamless type, ISI marked with monitoring tag & certificate. Vendor to also consider required identification mark (Std color coding, the extinguisher should be visible in No lights) as per Fire / IS Norms. Set 4.00 0
13.71.06 High Voltage Electrical Insulation Synthetic Mats, ISI Marked,confirming to IS:15652-2006. Types: Class C; for 1100V, Flame Retardant, Shock Proof, 1000 mm in width, pastable, Acid/Alkali/Diesel/Oil Resistant, CPRI/ERDA tested & Approved, Black/Gray in color etc. Rmt 30.00 0
13.71.07 415V Dangerboards of appropriate size & marking. Nos 15.00 0
13.73.01 16A 3Ø,3 Pin Socket and plug 16A SP MCB + 32A 3Ø, 5 Pin Socket and plug 32A TP MCB in a Readymade Box. Nos 3.00 0
13.73.02 8 SWG GI wire. Rmt 150.00 0
13.73.04 4Cx4Sqmm 2XWY Cu. Cable complete. Rmt 50.00 0
13.73.05 40W LED BATTEN INDUSTRIAL RAIL Nos 100.00 0
13.73.06 04 Way VTPN DB with 100a FP MCCB as incomer, and 1no.of O/G 10A SP MCB, 2no.of O/G 20A SP MCB, 3no.of O/G 32A TP MCB. Nos 1.00 0
13.74.00 Supply, Transporation, Unloading at site , Installation , Testing and Commissioning of 'Silent Type' Diesel Generating set (Indoor type) with AMF Function having Power rating of1500+250 KVA, 415 Volts at 1500 RPM 0.8 Lagging power factor, consiting of the followings & as per Tender technical specifications. The scope also includes the exhaust piping with Al cladding / insulation including the support structure of exhaust pipe as per CPCB norms & also obtaining approval /Permission from CPCB/Goverment electrical Inspector, Local Muncipal authority etc. DG set also iclude the fuel piping, First charging of Dry Batteries & First fill of Labrication oil. Diesel Engine: Diesel Engine: 4 stroke radiator cooled type with necessary fan, electric start with Electronic Governer, of suitable BHP at 1500RPM suitable for750KVA output of alternator at 45 degree C ,90% RH & 550 Meter MSL and confirming to BS 5514, BS 649, IS 10000, capable of taking 10% over loading for one hour after 12 hours of continious operation. The engine will be fitted complete with all the required accessories.The scope includes testing of engine as per Tender technical specification for electrical works. Alternator : Alternator rated at 1500+250 KVA, 415 Volts 50Hz at 1500 RPM,3 phase 50 Hz, AC supply with 0.8 lagging power factor at 45 degree C,90%RH & at 550 meter MSL. The alternator shall be SPDP enclosure, brushless, continious duty, self excited and self regulated through AVR confirming to IS 4722/BS2613 suitable for tropical conditions and with class F/H Insulation. The scope also includes required control cables between D.G. set to AMF panel to complete the works including required routine test at manufactures works & site test as per specifications. Adopter Box for cable termination with extension bus bars for termination suitable for Armoured cable power cables.
13.74.01 1500 KVA D.G. Set with acoustic canopy{ CPCB 4}, battery, AVM & HSD tank etc. and exhaust piping above building as per latest CPCB norms / requiremnt Set 2.00 0
13.74.02 250 KVA D.G. Set with acoustic canopy{ CPCB 4}, battery, AVM & HSD tank etc. and exhaust piping above building as per latest CPCB norms / requiremnt Set 1.00 0
13.74.03 2x1500+1X250 kVA DG sysn. Panel as per SLD with all DG controler for propoer function of panel in Auto / manual mode in case of mains fail. Set 1.00 0
13.77.02 Supply, Installation, Testing and Commissioning of ongrid Solar Photovoltaic Power Plant conforming to MNRE specifications as amended, consisting of Mono/Poly Crystalline silicon solar cells, net metering facility, necessary protections, earthing,mounted on Aluminium/Gl structure of suitable strength with following components complete as required:-a) Solar Photovoltaic Module of capacity 330 Wp or above, manufactured in India, conforming to IS 14286/IEC 61215, IS/IEC 61730-Part-1, IS/IEC 61730-Part-2. Solar Photovoltaic Module conversion efficiency shall not be less than 16.5%. PV modules used in solar power plants/ systems must be warranted for their output peak watt capacity, which should not be less than 90% at the end of 10 years and 80% at the end of 25 years. b) Power Conditioning Unit (PCU) of 350-800 V DC Input voltage range and 400 V AC, three phase, 4 wire, 50Hz +/- 2.5 Hz, output voltage suitable to generate AC Power with efficiency not less than 97%, total harmonic distortion less than 3% and suitable for ambient temperature from 0 to 50 degree C. The PCU shall adjust the voltage and frequency level to suit the Grid Voltage Frequency. c) Data Monitoring System complete with accessories. d) Fixing of Array junction box & Main junction box with IP 65 protection and termination arrangement for incoming and outgoing cable along with glands, lugs e)The liasoning with Statutory body for the solar panel panel shall be in the scope of contractor. The integration of the solar system with the existing electrical network is in the scope of the contractor.
13.77.03 For 125 kWp Solar generation material to used 1) 500 Wp Solar PV Panels with Structure, Earthing, Wiring, and other accessories 2) Power Conditioning Unit(PCU) 125 kWp3]Contractor to consider AC & DC junction box with breakers, AC/DC cables and all other require components and accessories to finish the job Set 1.00 0
TOTAL OF ELECTRICAL WORK 0
14. ELV & ICT WORKS
ADDRESSABLE FIRE ALARM SYSTEM
14.1 S/I/T/C of micro processor based intelligent addressable main fire alarm panel, central processing unit with the following loop modules and capable of supporting not less than 240 devices (including detectors) and minimum 120 detectors per loop and loop length up to 2 km, network communication card, minimum 320 character graphics/ LCD display with touch screen or other keypad and minimum 4000 events history log in the non volatile memory (EPROM), power supply unit (230 ± 5% V, 50 hz), 48 hrs back-up with 24 volt sealed maintenance free batteries with automatic charger. The panel shall have facility to connect printer to printout log and facility to have seamless integration with analog/digital voice evacuation system (which is part of the schedule of work under SH: PA System) and shall be complete with all accessories . The panel shall be compatible for IBMS system with open protocol BACnet/ Modbus over IP complete as per specifications.
14.1.1 10 loop panel Nos 1.00 0
14.1.1a S/I/T/C of networking card Nos 1.00 0
14.1.2 S/I/T/C of Power supply unit to drive the sounder and strobe cum sounder.It shall have inbuilt short circuit protection & Battery Charger.The unit shall deliver 24V DC 10amps and shall be segregated in such fashion that cable to the sounder/strobe cum sounder shall be optimised.Vendor to consider the required cable and termination accessories in scope of suppl.It shall have battery backup features for 30 min ,input power rating must be 220V AC 50Hz/60Hz. Nos 1.00 0
14.1.3 S/I/T/C of intelligent interface unit BACnet/ Modbus protocol i.e.Supplying communication links between building management system and fire alarm control panel complete as required. Nos 1.00 0
14.1.4 S/I/T/C of central graphical fire alarm management system to centrally monitor and operate the fire alarm system complete as required. Nos 1.00 0
14.1.5 S/I/T/C of repeater panel with 320 character/Touch screen LCD display with inbuilt reset,acknowledge and silence switches complete as required. Nos 1.00 0
14.1.7 S/I/T/C of intelligent analog addressable photothermal detector complete with mounting base complete as required.(Below False Ceiling) Nos 78.00 0
14.1.9 S/I/T/C of addressable photoelectric smoke detectors with required accessories Nos 348.00 0
14.1.10 S/I/T/C of addressable photoelectric smoke detectors with required accessories(Below False Ceiling) Nos 534.00 0
14.1.11 S/I/T/C of intelligent addressable thermal detector with rate of rise cum fixed temperature thermistor complete with base as required. Nos 8.00 0
14.1.12 S/I/T/C of addressable beam detector with short circuit isolator (inbuilt or separate) complete with emitter and receiver including connections with remote test features etc. complete as required. Nos 10.00 0
14.1.13 S/I/T/C of response indicator on surface/recessed MS Box having two LED, metallic cover complete with all connections etc. as required. Nos 343.00 0
14.1.14 S/I/T/C of addressable manual call point complete as required,with all required accessories. Nos 64.00 0
14.1.15 S/I/T/C of of addressable horn cum strobe complete as required,with all required accessories Nos 94.00 0
14.1.16 S/I/T/C of addressableof fault isolator complete with base as required. Nos 91.00 0
14.1.17 S/I/T/C of addressable control modules for access trip off with required accessories including gi. junction box and glands. Nos 10.00 0
14.1.18 S/I/T/C of addressable control modules for interface with pa system with required accessories including gi. junction box and glands. Nos 16.00 0
14.1.19 S/I/T/C of addressable control modules for AHU trip with required accessories including gi. junction box and glands. Nos 105.00 0
14.1.20 S/I/T/C of addressable control modules for fire damper with required accessories including gi. junction box and glands. Nos 28.00 0
14.1.21 S/I/T/C of addressable control modules for lift interface system with required accessories including gi. junction box and glands. Nos 11.00 0
14.1.22 S/I/T/C of addressable control modules for staircase pressurization with required accessories including gi. junction box and glands. Nos 9.00 0
14.1.23 S/I/T/C of addressable control modules for lift pressurization system with required accessories including gi. junction box and glands. Nos 11.00 0
14.1.24 S/I/T/C of addressable control modules for electrical panel tripping with required accessories including gi. junction box and glands. Nos 2.00 0
14.1.26 S/I/T/C of fire fighter phone jack with control module complete as required. Nos 30.00 0
14.1.27 S/I/T/C of addressable monitor modules for sprinkler flow switches, tamper switch etc. with required accessories including gi. junction box and glands. Nos 20.00 0
14.1.28 S/I/T/C of addressable monitor modules for fire fighting pump. with required accessories including gi. junction box and glands. Nos 12.00 0
14.1.29 S/I/T/C of addressable monitor modules for Beam detector. with required accessories including gi. junction box and glands. Nos 10.00 0
14.1.30 S/I/T/C of 2c x 1.5 sq.mm fire alarm armoured cable,600/1000V rated with annealed copper conductor having XLPE insulatio,steel wire armouring & FRLS outer sheath complete as required Rmt 23,920.00 0
14.2 PUBLIC ADDRESS SYSTEM
14.2.1 S/I/T/C of 6 zone ,voice alarm controller with USB, MP3 player (including 6 zone button paging station) with seamless integration facility with main fire alarm panel for voice evacuation complete as required. Nos 3.00 0
14.2.2 S/I/T/C of 1.5/3/6W ceiling speakers complete as required. Nos 372.00 0
14.2.3 S/I/T/C of 1.5/3/6W box wall speakers complete as required. Nos 79.00 0
14.2.4 S/I/T/C of 2.5/5/10W box wall speakers complete as required. Nos 2.00 0
14.2.5 S/I/T/C of digital audio amplifier 50Watt,25V rms operating at 240 volt AC supply complete as required. Nos 12.00 0
14.2.6 S/I/T/C of digital audio amplifier 75Watt,25V rms operating at 240 volt AC supply complete as required. Nos 15.00 0
14.2.7 S/I/T/C of Voice command keypad 6 zone,with microphone assembly complete as required. Nos 3.00 0
14.2.8 S/I/T/C of Fire Retardant cable PVC insulated copper conductor cable in existing surface/recessed steel conduit of following pairs and cores and size including connection and reconnection as required.
14.2.8.1 Spaeker cable Two pair, 2-core, 1.5 sqmm Rmt 6,776.00 0
14.2.8.2 Supply and Fixing 25 mm dia MS Flexible pipe with PVC coating along with all ancillaries and accessories like couplers etc. as required. Rmt 4,742.00 0
14.3 CCTV SYSTEM
14.3.1 S/I/T/C of Network Low-Light Infra Red (IR) Dome Camera, 1/2.8" CMOS, 5 Mega Pixel (MP) @ 25 Frames Per Second (FPS); Min. Illumination required 0.002 lux @ (color), 120dB True Wide Dynamic Rrange (WDR), Min. Pixels 2592 × 1920p, dual stream, Back light Compensation (BLC), High Light Compensasation (HLC), 3D- Digitial Noise Reduction (DNR), Auto White Balance, Privacy Mask, Region of Interest (ROI); Edge Intelligence: Motion Detection, Video Tampering; H.265, H.264 and MJPEG compression; Audio Input/Output, Alarm Input/Output; Smart IR with upto 40m Infra Red (IR) distance, 256 Giga Byte (GB) Secure Digital (SD) card; Power Over Ethernet (POE) Class 0 and 12 Volt Direct Current (DC), Ingress Protection - IP 65, Impact Resistance - IK 10 with Die-Cast Aluminium Housing, Having Operating temperature range : –40°C to 60° C. Certifications: ONVIF Profile S, G T compliant, Underwriters' Laboratories (UL) 60950-22, European Conformity (CE) (50130-4 & 55022), Federal Communications Commission (FCC) Part 15 and Restriction of Hazardous Substance (RoHS). including cable termination and fixing accessories complete in all respect. Nos 205.00 0
14.3.2 S/I/T/C of Network Low-Light Infra Red (IR) Mini Dome Camera, 1/2.8" CMOS, 2 Mega Pixel (MP) @ 25 Frames Per Second (FPS); Min. Illumination required 0.002 lux @ (color), 120dB True Wide Dynamic Rrange (WDR), Min. Pixels 1920 × 1080p, dual stream, Back light Compensation (BLC), High Light Compensasation (HLC), 3D- Digitial Noise Reduction (DNR), Auto White Balance, Privacy Mask, Region of Interest (ROI); Edge Intelligence: Motion Detection, Video Tampering; H.265, H.264 and MJPEG compression; Audio Input/Output, Alarm Input/Output; Smart IR with upto 20m Infra Red (IR) distance, 256 Giga Byte (GB) Secure Digital (SD) card; Power Over Ethernet (POE) Class 0 and 12 Volt Direct Current (DC), Ingress Protection - IP 65, Impact Resistance - IK 10 with Die-Cast Aluminium Housing, Having Operating temperature range : –40°C to 60° C. Certifications: ONVIF Profile S, G T compliant, Underwriters' Laboratories (UL) 60950-22, European Conformity (CE) (50130-4 & 55022), Federal Communications Commission (FCC) Part 15 and Restriction of Hazardous Substance (RoHS). including cable termination and fixing accessories complete in all respect. Nos 14.00 0
14.3.3 S/I/T/C of Network Low-Light Infra Red (IR) OutDoor Bullet Camera, 1/2.8" CMOS, 5 Mega Pixel (MP) @ 25 Frames Per Second (FPS);2.7–13.5 mm 5X motorized focus & zoom (MFZ) lens Min. Illumination required 0.002 lux @ (color), 120dB True Wide Dynamic Rrange (WDR), Min. Pixels 2592 × 1920p, dual stream, Back light Compensation (BLC), High Light Compensasation (HLC), 3D- Digitial Noise Reduction (DNR), Auto White Balance, Privacy Mask, Region of Interest (ROI); Edge Intelligence: Motion Detection, Video Tampering; H.265, H.264 and MJPEG compression; Audio Input/Output, Alarm Input/Output; Smart IR with upto 40m Infra Red (IR) distance, 256 Giga Byte (GB) Secure Digital (SD) card; Power Over Ethernet (POE) Class 0 and 12 Volt Direct Current (DC), Ingress Protection - IP 67, Impact Resistance - IK 10 with Die-Cast Aluminium Housing, Having Operating temperature range : –40°C to 60° C. Certifications: ONVIF Profile S, G T compliant, Underwriters' Laboratories (UL) 60950-22, European Conformity (CE) (50130-4 & 55022), Federal Communications Commission (FCC) Part 15 and Restriction of Hazardous Substance (RoHS). including cable termination and fixing accessories complete in all respect. Nos 74.00 0
14.3.3 S/I/T/C of Network Low-Light Infra Red (IR) InDoor Bullet Camera, 1/2.8" CMOS, 5 Mega Pixel (MP) @ 25 Frames Per Second (FPS);2.7–13.5 mm Min. Illumination required 0.002 lux @ (color), 120dB True Wide Dynamic Rrange (WDR), Min. Pixels 2592 × 1920p, dual stream, Back light Compensation (BLC), High Light Compensasation (HLC), 3D- Digitial Noise Reduction (DNR), Auto White Balance, Privacy Mask, Region of Interest (ROI); Edge Intelligence: Motion Detection, Video Tampering; H.265, H.264 and MJPEG compression; Audio Input/Output, Alarm Input/Output; Smart IR with upto 40m Infra Red (IR) distance, 256 Giga Byte (GB) Secure Digital (SD) card; Power Over Ethernet (POE) Class 0 and 12 Volt Direct Current (DC), Ingress Protection - IP 66, Impact Resistance - IK 10 with Die-Cast Aluminium Housing, Having Operating temperature range : –40°C to 60° C. Certifications: ONVIF Profile S, G T compliant, Underwriters' Laboratories (UL) 60950-22, European Conformity (CE) (50130-4 & 55022), Federal Communications Commission (FCC) Part 15 and Restriction of Hazardous Substance (RoHS). including cable termination and fixing accessories complete in all respect. Nos 8.00 0
14.3.4 S/I/T/C of 4MP TDN IR 40X Network IR PTZ Camera with minimum specifications as: Sensor Size: 1/1.8" CMOS, Progressive Scan; Effective Pixels: 2592 x 1520; Lens: 5mm~200mm (+/- 10% on each side), 40X optical zoom, DC-IRIS lens with Auto ICR (Infrared Cut Filter); Frames: 25 FPS for all resolution, 50 fps @ 1080p; Min. Illumination: 0.005 lux @ Color & 0 lux IR On; Electronic Shutter: 1/30,000 - 1/1; Smart IR with up-to 450m IR distance; Light Compensation: BLC, HLC, WDR 140dB; Advance Video Compression: H.265 HEVC, H.264 , MJPEG, Smart Codec; Streams: Triple Video Streams configurable at different Resolutions and FPS using H.265/H.264; Noise Reduction (3DNR); PTZ: 400 presets, 4 Patrols, 4 Tours and Auto Pan Scan support; Minimum Edge Intelligence: Smart motion, Scene Change, Intrusion, Multi loitering, People counter, Face detection, Line crossing detection, Unattended object detection, Missing object detection, Audio Detection, Auto-Tracking; Defog and Image Stabilization; 5 Privacy Mask and 5 ROI support; Security: HTTPS, TLS 1.2, Stream encryption, AES-128/256, Secure boot and Secure authentication Hardware Encryption Chipset Built-in; 1TB SD card support with SD card encryption, Signed and Encrypted firmware; Alarm I/O support: 7 In/2 Out; Two-way Audio Support: Line In /Out; Power: AC24V, HPOE, Heater; Environmental Protection: IP67, IK10; Operating temp range : –40°C to 70° C. Certifications: ONVIF Profile S, G, T, M (Listed on ONVIF Website); UL 62368-1, CE (EN 50130-4 & EN 55032), FCC Part 15, RoHS, PCI Data Security Standard, Secured by Default & NDAA Sec 889 compliant. Complete with Brackets suitable for wall / pole mounting as per site conditions and including power supply. Nos 4.00 0
14.3.5 S/I/T/C of 5 mtrs poles for mounting cameras with necessary accessories Nos 28.00 0
14.3.6 S/I/T/C of ANPR Camera Software. Nos 10.00 0
14.3.7 S/I/T/C of Video Management Software Supporting Onvif Profile S & G(Listed On Onvif Website), Psia, Real Time Streaming Protocol (Rtsp) Standards, Should Support 4k Resolution Gpu Rendering On H.264 / H.265 Video Compression Codec. Proposed Vms Should Include 315 Channel Licenses. Video Management Software Shall Include - 1) Perpetual Software Licence, Must Not Be Renewed Periodically 2) Digital Signature And Password Protection On Exported Clips 3) Calender Search With Thumbnail Image Preview Of Recording And Quick Export Of Video Clips 4) Smart Motion Detection On Recorded Video For Multiple Region Of Interest; 5) Tracking Object From Selected Set Of Interlinked Surrounding Cameras With Smart Algorithm (With Min. 12 Cameras) 6) Camera Grid/Layout Sharing Within Operators 7) Create And Save Virtual Cameras In Layout By Digitally Zooming Into The Field Of View Of Camera 8) 3d Positioning To Allow The Operator To Pan, Tilt And Zoom Into A Specific Region Of Interest By Just Clicking The Live View 9) Video Recording On Demand And Adaptive Network Throttling By Auto-Switching Of Camera Streams 10) Custom Video Archival For Every Camera Maximum Upto 5 Years On Fifo Basis 11) View The Video Captured During Pre-Alarm, On-Alarm, Post-Alarm And Live Video From The Camera In A Single 2x2 Layout. 12) Data Encrypted And Secured Transmission On Tls 1.2, Secured By Default Certified 13) Email Event History And Operator Log Reporting With Export To Pdf, Crystal Reports, Ms Excel/Ms Word From Vms Client 14) Gpu Decoding At H.264 / H.265 For 4k Resolution On Cameras 15) Playback With Speeds Ranging From 1/64x To 64x. Smooth Reverse Playback Allows User To View The Reverse Playback Operation Without Any Jerk In The Playback Video Upto 2x Speed. 16) Colored Timeline Depicting Different Recording Happening In The Vms With Min. 3 Colors Software Oem Should Have Toll Free Number For Technical Or Service Support. Lumpsum 1.00 0
14.3.8 S/I/T/C of Recording Server Supporting Onvif Profile S & G, Psia, Real Time Streaming Protocol (Rtsp) Standards, Emerging Technologies In The Industry, Like 4k Resolution, H.264 / H.265 Video Compression Codec. System Proposed Shall Have Scalability Upto 64 Cameras Per Recorder With Sufficient Licenses To Record All The Cameras In This Requirement. It Shall Support Simultaneous Recording, Live Monitoring, Playback/Search Of Recorded Video For All Cameras Supporting, Support Scheduled Backfilling Of The Recordings From The Edge Storage/Sd Card Of Cameras For Robust Recording Against Temporary Network Failure. Recording To Be Considered For 31 Days At Full Resolution, 25 Fps In Raid 5. Vendor To Submit Storage Calculation. It Shall Have Intel® Core™ Xeon™ W-2235, 3.8 Ghz, Minimum 16gb Ram, Single 950w Power Supply, Os Drive: 250gb M.2 Ssd; 5 Field Upgradable Bays Supporting Upto 12 Tb Sata Hard Drives Per Bay, Raid Controller With 4gb Cache Memory Supporting, 0, 1, 5, 6, 10. Nic Card: 2 X 1gbe Supporting Network Throughput Of 570 Mbps, Windows 10, Microsoft Sql Express 2014/2016. 1920x1080 Pixels; Standard Vga/Hdmi Graphics Adapter With Mdp Ports:, Cd/Dvd Rom; Usb Keyboard And Mouse, 3 Usb. Certifications: Ul, Ce/En, Fcc, Rohs. Lumpsum 1.00 0
14.3.9 S/I/T/C of VMS Server Hardware as per following specifications: Intel(R) Xeon(R) Gold 5315Y CPU @ 3.20GHz or higher, 16 processors or higher, Microsoft Windows® Server 2022 64-bit, Microsoft SQL Express/Standard 2019, System Memory (RAM): 32GB, Optical Drive: DVD+/-RW, Hard Disk Drives: Two seperate sets of RAID arrays. RAID set 1 utilizing 10K-15K RPM SSD 480 GB for OS and application, RAID set 2 utilizes 10K-15K RPM SSD 480 GB for DatabaseSQL ; Network Interface Card (NIC): Dual or compatible pair of NICs, 1 Gbps, Human Interface: 102-key keyboard and a mouse pointing device, Video Adapter: 32-bit color or higher, video resolution 1280x768 pixels, 65K colors non-interlaced, Windows Media Player Version 12, Redundant Power supply, UPS, associated cables etc. complete as required. Nos 1.00 0
14.3.10 S/I/T/C of Client Workstation As Per Following Specifications: Intel® Core™ Intel Core I7-10700, Os - Genuine Microsoft Windows® 10 Enterprise 64-Bit, Ram - 16gb, Hard Drives - 500 Gb 7200rpm Sata3, Video Adaptor - Integrated Intel Uhd Graphics 630 Supporting 2 Monitors Over Hdmi/Vga, Network Connection - 1 Gbit/Sec Or Greater, Two(2) Pci-Express Expansion Slots 2/4 Usb, Cd/Dvd Rom, Usb Keyboard And Mouse, Ups, Associated Cables Etc Complete As Required. Nos 4.00 0
14.3.11 S/I/T/C of Color High Resolution Led Tv Comprising Of 42 Inch Display, Full Hd,Hdmi Input Provision; Complete With All Supports And Accessories. Nos 9.00 0
14.3.12 S/I/T/C of Hdd, 8 Tb, 7200 Rpm, Sata 6 Gb/S, Including Fixing Accessories And Cable Termination With Required, Complete In All Respect. (Raid 5 Configuration) Nos 41.00 0
14.4 ACCESS CONTROL SYSTEM
14.4.1 S/I/T/C of 13.56mhz smart card reader with built-in buzzer, color led and tamper output, iso 14443a/b, max read range upto 2-3 inch with weigand data format, suitable for indoor/outdoor applications, ce, fcc, ul294 and rohs compliant, operating temp 0 to 60 deg c as per specification suitable for mounting on metal surface/metal frames or wooden frames wall or as required based on site conditions. Nos 20.00 0
14.4.3 S/I/T/C of 2 reader intelligent controller with built in lan/web server, upgradeable flash memory, 8 supervised inputs and 4 form c relay outputs with 32-bit cpu, 32 mb flash memory, 16 mb sdram memory, real-time clock, dedicated tamper and power fail alarm, support anti pass back (global & local), 8 card formats and 8 facility codes, 128 access levels, 255 holidays and 127 time zones, tcp/ip and rs-485 connectivity, 100,000 card holder and 100,000 offline event buffer, removable terminal blocks wtih color-coded labels, ce, fcc listed. complete with cabinet, power supply, mounting bracket, 3-pin top with 1.5 mts power cable, 4 hrs battery backup and all necessary accessories & peripheral items for civil, electrical works as required. Nos 10.00 0
14.4.4 S/I/T/C of anti-virus software for all pc mentioned below (latest at the time of supply with license ver.) Nos 1.00 0
14.4.5 S/I/T/C of client workstation as per following specifications:intel® core™ intel core i7-8700, 3.2 ghz, os - genuine microsoft windows® 10 enterprise 64-bit, ram - 16gb, hard drives - 1 tb 7200rpm sata3, video adaptor - integrated intel uhd graphics 630 supporting 2 monitors over hdmi/vga, network connection - 1 gbit/sec or greater, two(2) pci-express expansion slots 2/4 usb, cd/dvd rom, usb keyboard and mouse, ups, associated cables etc complete as required Nos 1.00 0
14.4.6 S/I/T/C of color high resolution led tv comprising of 42 inch display, full hd,hdmi input provision; complete with all supports and accessories. Nos 1.00 0
14.4.7 S/I/T/C of enterprise version access control software supporting 5 users and time attendance software. capable of integrating any number of card readers. manage cardholders across multiple sites, ms sql based, multiple door modes: lockout, lockdown, pin only, card+pin, card or pin, card only. the software suite shall comprise various integrated software modules that allow for the full integration and retrieval of transactions from the hardware, as well as alarm monitoring, reporting, and scheduling capabilities. should also support web clients. following features, + zone-related software features, + supervisor card unlock, + card-related software features, + time-limited access, + seemless integartion with cctv system + pin codes, + suspension of cards, + multiple card access + card access groups, + time patterns (schedules), + anti-pass back (apb) control + reporting including tracking and muster report with time stamping + first card rule (activates the door time zone) + two card rule-supervisor card and regular card to allow access + time zone card toggle for door locks, + manual override of system functions + latching mode for door locks , + ldap based and application logon users + inbuild guard tour module, + dynamic floor plans and photo-id badging Nos 1.00 0
14.4.9 S/I/T/C of electromagnetic lock (fail safe type) including necessary mounting brackets. supply shall be complete with l/c/z bracket. double leaf:1200 lbs Nos 3.00 0
14.4.10 S/I/T/C of magnetic contact for doors with all necessary accessories, civil, electrical works & peripheral items, as required. Nos 6.00 0
14.4.12 S/I/T/C of emergency exit switch or break glass unit with feedback (doube pole double throw), key resettable, green colour, fireproof material , suitable for single gang box (including surface mounted back boxes/concealed gi back boxes.) Nos 3.00 0
14.4.13 Supply, Installation, Testing & Commissioning of 1+ 1 Lane configuration (1 Standard + Wide Lane) Swing gates With Stainless steel frame and acrylic flap with 520 mm passage for standard lane & 900mm for wide lane,DC brushless Motor based Highly reliable drive and with tail gate detection feature. Nos 2.00 0
14.4.14 Supply, Installation, Testing & Commissioning of 2+ 1 Lane configuration (2 Standard lane ) Swing gates With Stainless steel frame and acrylic flap with 520 mm passage for standard lane & 900mm for wide lane,DC brushless Motor based Highly reliable drive and with tail gate detection feature. Nos 1.00 0
14.4.15 S/I/T/C of 8c x 0.5 sq.mm frls armoured cable. atc conductor stranded, pvc insulated to form a core, cores laid up, overall shielded with alu-mylar tape with tinned copper drain wire of size 0.5 sq. mm, pvc innersheathed g.i. wire armoured, pvc sheathed cable (colour: gray) Rmt 1,050.00 0
14.4.16 S/I/T/C of 2c x 1.0 sq.mm frls armoured cable. atc conductor stranded, pvc insulated to form a core, cores laid up, overall shielded with alu-mylar tape with tinned copper drain wire of size 0.5 sq. mm, pvc innersheathed g.i. wire armoured, pvc sheathed cable (colour: gray) Rmt 375.00 0
14.4.17 S/I/T/C of 4c x 1.0 sq.mm sq.mm frls armoured cable. atc conductor stranded, pvc insulated to form a core, cores laid up, overall shielded with alu-mylar tape with tinned copper drain wire of size 0.5 sq. mm, pvc innersheathed g.i. wire armoured, pvc sheathed cable (colour: gray) Rmt 100.00 0
14.5 PASSIVE SECURITY SYSTEM
14.5.1 S/I/T/C of multi-zone door frame metal detector not less than 8 real detection zones with all required accessories. Nos 4.00 0
14.5.2 S/I/T/C of handheld metal detector with docking station and built-in charger.with low battery alarm,adjustable detection sensitivity for different requirements,with led for battery/charging indication.with high detection speed with big probe area.with drop-proof protection. Nos 4.00 0
14.5.3 S/I/T/C of x-ray baggage sacnner with all required monitoring station, hardwares & accessories.Tunnel size - 650 mm x 500 mm (for baggage) Nos 2.00 0
a boom barrier 2.5 M Nos 2.00 0
b boom barrier 3 M Nos 2.00 0
c boom barrier 3.5 M Nos 4.00 0
d boom barrier 4 M Nos 2.00 0
14.5.5 S/I/T/C of Frisking Booth with all required fixing and mounting accessories. Nos 2.00 0
14.6 PASSIVE-NETWORK
14.6.5 S/I/T/C of UTP 4 pair CAT 6 LAN Cable in the existing surface/ recessed Steel/ PVC conduit as required.(2 runs) Rmt 41,860.00 0
14.6.6 S/I/T/C of keystone shielded outlet, 180dg c6. Nos 745.00 0
14.6.7 S/I/T/C of cat-6 patch cord high speed 10 gigabit 26awg s/ftp patch cord grey, lszh, c6, 1m(user side). Nos 282.00 0
14.6.8 S/I/T/C of cat-6 patch cord high speed 10 gigabit 26awg s/ftp patch cord grey, lszh, c6, 3m(rack end side). Nos 608.00 0
14.6.9 S/I/T/C of backbox for faceplate- box uk style. Nos 234.00 0
14.6.10 S/I/T/C of cat6 face plate shuttered uk style, single. Nos 234.00 0
14.6.12 S/I/T/C of rj45 i/o with required accessories. Nos 1,216.00 0
14.6.13 S/I/T/C of copper panel staggered shielded c6a, 24 port unloaded 1u wire manager included. Nos 33.00 0
14.6.14 S/I/T/C of 12 core indoor armoured cable (mm om-3 / sm) optical fiber cable Rmt 2,000.00 0
14.6.15 S/I/T/C of 24 core fiber sc-style, (mm om-3 / sm), wall mount fiber liu, loaded with adapter plate, pigtail & standard mounting hardware & accessories Nos 30.00 0
14.6.16 S/I/T/C of lc-sc style (mm om-3 / sm) duplex patch cord -5 mtrs. Nos 60.00 0
14.6.17 S/I/T/C of 42u (800w x 1000d)mm floor mount closed rack with front glass door, vertical wire management systems, fan tray on top, perforated rear doors, side doors, casters, opeanable entry at the bottom for the cable & 2 nos vertical power strip with standard accessories. with heavy shelf with sliding keyboard tray, catilever shelf and all necessary hardware to mount the passive & active equipment (pkt of 20). 19" 1u horizotal wire manager (one way) Nos 8.00 0
14.6.18 S/I/T/C of 15u (600w x 600d)mm wall mount closed rack with front glass door, vertical wire management systems, fan tray on top, perforated rear doors, side doors, casters, opeanable entry at the bottom for the cable & 2 nos vertical power strip with standard accessories. with heavy shelf with sliding keyboard tray, catilever shelf and all necessary hardware to mount the passive & active equipment (pkt of 20). 19" 1u horizotal wire manager (one way) Nos 2.00 0
14.6.19 S/I/T/C of 9u (600w x 600d)mm wall mount closed rack with front glass door, vertical wire management systems, fan tray on top, perforated rear doors, side doors, casters, opeanable entry at the bottom for the cable & 2 nos vertical power strip with standard accessories. with heavy shelf with sliding keyboard tray, catilever shelf and all necessary hardware to mount the passive & active equipment (pkt of 20). 19" 1u horizotal wire manager (one way) Nos 4.00 0
14.6.20 S/I/T/C of 6u (600w x 600d)mm wall mount closed rack with front glass door, vertical wire management systems, fan tray on top, perforated rear doors, side doors, casters, opeanable entry at the bottom for the cable & 2 nos vertical power strip with standard accessories. with heavy shelf with sliding keyboard tray, catilever shelf and all necessary hardware to mount the passive & active equipment (pkt of 20). 19" 1u horizotal wire manager (one way) Nos 16.00 0
14.6.21 Providing & erecting Hot-Dip Galvanised Perforated type Cable tray with cover manufactured from 16 swg (1.6 mm thick) GI sheet of 300 mm width & 100 mm height complete with necessary coupler plates, hanging arrangement & hardware in approved manner. Rmt 450.00 0
14.6.22 Providing & erecting Hot-Dip Galvanised Perforated type Cable tray with cover manufactured from 16 swg (1.6 mm thick) GI sheet of 200 mm width & 50 mm height complete with necessary coupler plates, hanging arrangement & hardware in approved manner. Rmt 410.00 0
14.6.24 S/I/T/C of Data Cabling in medium class PVC conduit along with the accessories in surface /recess including the cutting the wall and making good the same in case of recessed conduit as required.25mm Rmt 23,400.00 0
14.7 NETWORK ACTIVE
14.7.1 S/I/T/C of L3 Fully Manageable + Stackable Switch: 12 x 1G SFP+12 x 1G SFP ports and 4 x 10G SFP+ 2x40G uplink ports, with dual hotswap PSU. including standard accessories with 5 years warranty. Nos 2.00 0
14.7.2 S/I/T/C of MM 10G SFP+ Module with Standard Nos 33.00 0
14.7.4 S/I/T/C of L2 Fully Manageable + Stackable Switch: 24 RJ-45 auto-sensing 10/100/1000 ports with 2 combo ports (10/100/1000T or 100/1000X SFP) and 2 SFP+ stacking Uplink Ports including standard connectivity accessories with 5 years warranty. Nos 6.00 0
14.7.6 S/I/T/C of L2 Fully Manageable + Stackable Switch: 24 RJ-45 POE+ auto-sensing 10/100/1000 ports with 2 combo ports (10/100/1000T or 100/1000X SFP) and 2 SFP+ stacking Uplink Ports including standard connectivity accessories with 5 years warranty. Nos 27.00 0
14.7.7 S/I/T/C of MM 1G SFP+ Module with Standard Accessories (vendor to calculate at actual SFP module requried as per the make selected) Nos 33.00 0
14.7.10 S/I/T/C of Wi-Fi 7 (IEEE 802.11be) Indoor Access Point with required mounting accessories. Nos 24.00 0
14.7.11 S/I/T/C of Wireless Controller for centralized Wi-Fi- with 5 year warranty. Nos 1.00 0
14.8 IPABX SYSTEM
14.8.1 S/I/T/C of Pure IP at core server Based voice solution with 04 Port Voicemail ,04 Port FXS ,04 Port FXO ,1 PRI Trunk lines (30 Ch) Circuit with CLIP Facility ,100 IP users License Expandable upto 200 Users,01 Nos. IP Operator Console,100 Party Conference ,Speed Dial, Music on Hold , Internal/ External ring difference ,Call Barring, Call Pickup, TEC should be with GR Number, - Redundant server in active-Active mode.(Vendor to suggest as per the make and model selected.) Nos 1.00 0
14.8.2 S/I/T/C of IP Telephone Set. Nos 86.00 0
14.9.1 S/I/T/C Construction of cable chambers with complete supply of brics masonry, chamber covers & other accessories.
14.9.3 S/I/T/C of 150mm HDPE pipes complete with accessories. Rmt 550.00 0
14.9.4 S/I/T/C of 100mm HDPE pipes complete with accessories. Rmt 315.00 0
14.9.5 S/I/T/C of 50mm HDPE pipes complete with accessories. Rmt 310.00 0
14.9.6 S/I/T/C of 25mm HDPE pipes complete with accessories. Rmt 25.00 0
14.10 INTRUSION SYSTEM
14.10.1 S/I/T/C of 4 zone Control Panel. Nos 4.00 0
14.10.2 S/I/T/C of wireless glass break detector Nos 20.00 0
14.10.3 S/I/T/C of wireless digital PIR motion detector Nos 20.00 0
14.10.4 S/I/T/C of wireless recessed Contacts. Nos 40.00 0
14.10.5 S/I/T/C of wireless indoor siren Nos 12.00 0
14.10.6 S/I/T/C of wireless out-door siren Nos 10.00 0
14.10.7 S/I/T/C of signal cables. (2 core 1 mm2),[1 pair] twisted with overall shield PVC insulated, tinned copper conductor cable,Flexible cable Rmt 600.00 0
14.11 BMS SYSTEM
CENTRAL CONTROL STATIONS
14.11.1 S/I/T/C of the Central Control Stations consisting of the following complete as per tender specification. Nos 2.00 0
14.11.2 S/I/T/C CPU consist of i-7 , suitable Motherboard & Graphic Card, 8 GB RAM [ Expandable up to 32GB ], 500 GB Hard Disk, DVD Writer 52X, Multimedia, modem as per specifications.with Keyboard and mouse Set 2.00 0
14.11.3 S/I/T/C Colour Monitor SVGA - 22 “ Nos 2.00 0
14.11.4 S/I/T/C A4 size Printer Nos 1.00 0
14.11.5 S/I/T/C Windows 10-11 operating system as spported by the BMS OEM Nos 2.00 0
14.11.6 S/I/T/C of the Graphical Software providing the facility to create / provide the following, static and animate the Graphics, Navigation between pages, display of logs, changing the time zones, popup alarms, with Unlimited number of user license configurable password protection for Building Automation System as per Specifications. The BMS platform shall natively support standard communication protocols such as BACnet™/Lonwork etc. The Software should be capable enough to transmit messages on Email Alerts. The software should be Web Based Software Required to remotely monitor the system for unlimited users.Software should support upto 5000 points This Software should have the following Key features 1. WEB BASED TOOL. NO ADDITIONAL SOFTWARE REQUIRED. 2. EMAIL / SMS OPTION AVAILABLE 3. MULTIPLE DATABASE SOURCES / SITE CAN BE INTEGRATED. 4. HTML5 based Software is recomended All should be completed as per tender specification. Set 1.00 0
14.11.7 S/I/T/C Energy Monitoring Software shall be part of proposed BMS software – The software shall display both real time and historical values. Displays in various views including Calendar, graphical and tabular, Line, Pie chart and bar chart. Based on the meter values hourly, daily, weekly and monthly consumption values shall be calculated and displayed. The software shall have facility to define alarms for certain consumption values. There shall be a comparative chart for definable periods for Energy analytics. Defined users shall be able to view the details through Desktop, Mobile or Ipad with auto adjust views based on the type of the device. Set 1.00 0
THIRD PARTY INTEGRATOR
14.11.8 S/I/T/C the necessary Hardwares/Softwares for Integrating it with following 3rd party Devices on Bacnet/Lonworks/Modbus etc., as per distribution given below complete as per tender specification. Set 1.00 0
Load Manager (Refer IO Summary for no of points and devices)
DTM located in Emergency Panel & Lift Panel (Refer IO Summary for no of points and devices)
UPS Integration (Refer IO Summary for no of points and devices)
Fire Alarm System (Refer Fire Alarm BOQ)
DG Set (Refer IO Summary for no of points and devices)
Electrical Soft points refer Electrical IO summary.
DDC CONTROLLERS
S/I/T/C of the following equipment for BMS complete as per tender specification.
14.11.14 Network controller - Providing, installing, testing and commissioning of Microprocessor based 32 Bit Network Supervisory Controller unit for connecting all controllers and 3rd party System Integration Units to it and for transferring data to PC platform. (A) The unit shall comply following codes and standards: UL, FCC and CE. (B) The unit shall support protocol like BACnet (ASHRAE/ANSI 135 standard- and ENV-1805-1/ENV-13321-1)Modbus TCP (C) Shall be able to store reports and event logs. (D) WEB ENABLED / REMOTE DIALING to the unit shall be possible. The controller shall capable of connecting the future expansion DDCs / Integrators. The Controller shall be able to support communication protocol like Lontalk /BACnet /Lonworks etc. controllers. Lumpsum 1.00 0
14.11.15 Programmable and Application specific controller - Providing, installing, testing and commissioning of field mounted DDC controllers (Preferably LAN based ) of the following configurations and as per below specifications: (A) The programmable controllers processors shall be 32-Bit, BTL Certified (B) Analog to Digital and Digital to Analog resolution shall be 12 bit for greater accuracy. (D) Controllers shall support easy GRAPHICAL programming and shall be able to store the programs in the controller itself rather than storing it in PC. (E) The programmable controller shall have Universal input points and each input shall be capable of sensing PULSE signals. The DDC Controllers shall be on BACnet The DDC controller shall be as per the I/O Summary. Equipments, The Controller Selection shall be such that Distance from Controller to Field Devices should be minimum . NOTE : There shall be seperate field mounted controller for each AHU.
14.11.15.1 DDC CONTROLLERS(Vendor to calculate exact number of DDC required as per the make and model selected.) Nos 93.00 0
14.11.15.2 Local make Enclosure for the below units shall have NEMA-1 vandal proof, lockable and secure powder coated MS cabinets and the complete assembly for DDC controllers Nos 93.00 0
SENSORS AND FIELD DEVICES
14.11.18 S/I/T/C of Out Door Air Temp 0-50 Deg C Nos 1.00 0
14.11.19 S/I/T/C of Out Door Air RH 0-100 % Nos 1.00 0
14.11.20 S/I/T/C of Pipe Tempreture 0-50 Deg C Nos 16.00 0
14.11.21 S/I/T/C of Pipe Pressure 0-10 KG/Cm2 Nos 10.00 0
14.11.22 S/I/T/C of Pipe Flow CMH Nos 2.00 0
14.11.23 S/I/T/C of 2-Way Picv/contral valve Nos 1.00 0
14.11.24 S/I/T/C of 3-Way contral valve Nos 12.00 0
14.11.25 S/I/T/C of Level Transmitter Nos 4.00 0
14.11.26 S/I/T/C of Room RH 0-100 Nos 43.00 0
14.11.27 S/I/T/C of Room temp sensor 0-50 Nos 66.00 0
14.11.28 S/I/T/C of Room Return temp 0-50 Nos 15.00 0
14.11.29 S/I/T/C of AHU TT 0-50 Nos 14.00 0
14.11.30 S/I/T/C of DPS 0-25 mm Nos 80.00 0
14.11.35 S/I/T/C of CHW valve Nos 39.00 0
14.11.37 S/I/T/C of Heater TFU Nos 3.00 0
14.11.38 S/I/T/C of Humidifiers Nos 14.00 0
14.11.39 S/I/T/C of DPT 0-60 Pa Nos 10.00 0
14.11.41 S/I/T/C of Water Level Switches: 2 level Nos 14.00 0
14.11.42 S/I/T/C of Oil Level Switch 3 level Nos 1.00 0
CABLES & CONDUITS
S/I/T/C ofof the following Cables complete as per tender specification.
14.11.43 S/I/T/C of signal cables. (2 core 1 mm2),[1 pair] twisted with overall shield PVC insulated, tinned copper conductor cable,Flexible cable Rmt 7,000.00 0
14.11.44 S/I/T/C of signal cables. (4 core 1 mm2),[1 pair] twisted with overall shield PVC insulated, tinned copper conductor cable,Flexible cable Rmt 3,500.00 0
14.11.45 S/I/T/C of communication cables. (4 core 1 mm2),(2 pair) twisted with individual & overall shield PVC insulated, tinned copper conductor cable. Flexible cable Rmt 4,000.00 0
14.11.46 S/I/T/C of LAN cables CAT-6 for BMS Controller connectivity Rmt 4,500.00 0
14.11.47 S/I/T/C of power cables from UPS point to the respective devices and controllers. (3 core 2.5 mm2), PVC insulated, tinned copper conductor cable. Flexible cable Rmt 3,400.00 0
S/I/T/C of the following Conduits complete as per tender specification.
14.11.48 S/I/T/C of GI conduits for underground work of 25mm dia complete with all accessories. [shafts] Rmt 800.00 0
14.11.49 Flexible PVC conduit of 25 mm dia for over ground work. Rmt 1,500.00 0
14.11.50 Rigid PVC conduit of 25 mm dia for over ground work. Rmt 1,500.00 0
S/I/T/C of of Perforated GI cable tray with Cover : complete with supports, all fittings and mounting accessories, etc. complete to installation requirements. All Bends / Tees for cable trays shall be factory fabricated and not site fabricated
14.11.53 S/I/T/C of 24 Port POE with switching capacity of 256 Gbps, forwarding performance 190 Mpps, having 24 x 10/100/1000BASE-T PoE-(RJ45) with minimum PoE budget of 370W and 4x 10G SFP+ uplink ports, should have support for Stacking with stacking bandwidth of minimum 128 Gbps. Should support min 2GB internal DRAM, 2GB internal Flash memory,32K MAC address, 1K IPv6 Multicast Routes, Should have static Routing from day 1 and upgradable to support OSPF and VRRP with 1 year support.Switch should be fully manageable. Nos 4.00 0
TOTAL OF ELV & ICT WORKS 0
15.1 SITC FOR PART I - CHILLERS
15.1.1 VFD Driven, Water Cooled Screw Type Chilled Water Generator with Microprocessor based Panel with BACnet Gateway, to Connect to Plant Manager / Plant Optimizer Operating at 31°C Condenser Cooling Water Inlet, and 7°C Chilled Water Outlet with 12°C Inlet, 210 CMH Chilled Water Flow Rate, 262.5 CMH CW Flow Rate, with Shell & Tube Type Condenser & Evaporator, Fouling Factor - 0.001 for Condensers and 0.0005 for Evaporator in FPS Units,with VFD, suitable for Remote Start / Stop and Auto / Manual Operation with Even No of Passes & Heat Exchange Note : Harmonic Filter Current THD < 4% for each Chiller to be included in Chiller Prices. Minimum efficiency: AHRI Full Load ≤0.5746 ikW/TR | AHRI IPLV ≤0.549 ikW/TR Also Need to furnish efficiency as per IS 16590 - ISEER Ratings Complying to all the technical specifications attached and Chiller rates to include the following: 1) Transportation, loading, unloading, rigging and local erection of chillers at Lower ground floor level of building considering site feasibility and challenges to be included in the rate. 2) Inclusive of charges for 4 point chiller testing at factory for each chiller. 3) Flow switches for each chiller
15.1.1.1 Capacity : 350 TR (2W) + (1S) Nos 3.00 0
15.1.2 Supply, Installation, testing & Commissioning of Common Automatic Tube Cleaning System with all required accessories, (W+S) pumps, control panel and required supports, Suitable for tube cleaning of following chillers: 3 nos. x 350 TR WC Screw chillers Complying to all the technical specifications attached Set 1.00 0
15.2 SITC OF PART II - OTHER HIGH SIDE EQUIPMENT
Note: Transportation, loading, unloading, rigging and local erection of high-side equipment to be included in respective rates. No separate charges will be provided for the same.
15.2.1 Supply, Installation, testing & Commissioning of VFD driven CTI Approved Induced Draft, Twin Cell Counter Flow Type FRP Cooling Tower to Cool 262.5 CMH (350 TR Cooling Capacity Each) of Water from 36°C to 31°C at 27.8°C WBT, at 60.5 M Elevation (2W + 1S) with Fan having Motor of > IE3 and equipped with VFD. Performance efficiency to be ≥ 42 GPM / HP Maximum 0.002% drift loss of re-circulated water volume. Complying to Technical Specifications Attached Note: Each Cooling Tower to be rated for 350 AC TR, however, should be rated for not less than 435 TR Heat Rejection Capacity. Nos 3.00 0
15.2.2 Supply, Installation, testing & Commissioning of 35 mm Antimicrobial / Microban Insulated, Vertical Inline Chilled Water Primary Variable Flow Pumps Motor of > IE3 Efficiency with Head Mounted VFD Complying to Technical Specifications Attached
15.2.2.1 210 CMH Vs 32 M Head (2W+1S) Nos 3.00 0
15.2.3 Supply, Installation, testing & Commissioning of Vertical Inline Condenser Water Pumps with VFD, & Controller for Sequence, Speed etc. with Built in Logic Motor of > IE3 Efficiency with Head Mounted VFD Complying to Technical Specifications Attached
15.2.3.1 262.5 CMH Vs 23 M Head (2W+1S) Nos 3.00 0
15.2.4 Supply, Installation, testing & Commissioning of Vertical Inline Warm water Pumps with Fixed speed motor of > IE3 Efficiency. Pumps to have IP65 rating, include protective canopy suitable for outdoor installation. Complying to Technical Specifications Attached
15.2.4.1 77 CMH Vs 30 M Head (1W+1S) Nos 2.00 0
15.2.5 Supply, Installation, testing & Commissioning of Non-Chemical Condenser Water Treatment Unit Suitable for 3 nos. Cooling Towers (2 W + 1 S) of above-mentioned Capacity with Bac Comber Technology including the following: 1) Inductor Coil in the outlet pipe that generates ULF waves 2) Emitter Unit which is immersed in the cooling tower basin for control of Algae. 3) Electronic Control Unit that is connected to both the inductor coil and emitter unit. This is to be placed close to CT. Set 1.00 0
15.2.6 Supply, Installation, testing & Commissioning of Dirt Separator, for Chilled Water system, 250 NB, Max. Rated for flow of 420 CMH, Complying to the attached technical specifications Nos 1.00 0
15.2.7 Supply, Installation, testing & Commissioning of 35mm Antimicrobial / Microban Insulated with cladding, Closed Diaphragm Type Expansion Vessel 1000 Lts. With Pressurization Unit and Water Make-up connections. Rated for 10 Bar Operation Pressure Complying to the attached technical specifications Nos 1.00 0
15.2.8 Supply, Installation, testing & Commissioning of Automatic Vacuum Degasser suitable for 32 M3 Volume, 10 Bar operating Pressure with feed pumps for make up to Chilled Water Side and Fresh Water Inlet, Connection between piping & degasser, Inlet / outlet connection with built-in Microprocessor based Controller Complying to the attached technical specifications Nos 1.00 0
15.2.9 Supply, Installation, Testing & Commissioning of Filtration Module, Skid Mounted for 1μ, Module suitable for 32 M3 Primary side Volume & 32 M3 Condenser side vol. with (1W+1S) Pumps Starters, Flow Indicator etc. Complying to the attached technical specifications Set 1.00 0
15.2.10 Supply, Installation & testing of Pot Strainer with SS 40 Mesh, & SS Basket 300 NB, Max. Flow of 525 CMH should have canopy / weather protection if deemed required Complying to the attached technical specifications Nos 1.00 0
15.2.11 Supply, Installation, testing & Commissioning of Electrical Power Distribution Panel, including Intelligent Digital Power Meter with transmission, Incoming ACBs / Outgoing MCBs MCCBs, Voltmeter, Ammeter, Lamps & Switches, Contactors etc. with Transformer for Supply to Controllers / Control Valves / Sensors, etc. including power/ Energy meters (kwh) suitable for Local / Remote Operation HVAC Panel to have provison of auto tripping and restart on receipt of fire signal and Feed Backs with suitable Feeders for below mentioned equipment: Complying to the attached technical specifications, having IP55 rating for panels located indoors and IP65 rating for panels located outdoors
15.2.11.1 Panel No. 2A - 3 Nos. of Chillers Refer to attached panel list for reference of list of feeders to be included Nos 1.00 0
15.2.11.2 Panel No. 2B - 3 Nos. of CHW Primary Pumps, 3 Nos. CW Pumps, 1 No.Vaccum Degasser, 1No. Filtration module, etc. Also including feeders for AHU, VRV ODU, etc. Refer to attached panel list for reference of list of feeders to be included Nos 1.00 0
15.2.11.3 Panel No. 24 - 3 No. Cooling Towers with VFDs, Condenser Water Treatment Unit, Warm Water Pumps, Spares, etc. Refer to attached panel list for reference list of feeders to be included Nos 1.00 0
Note: Ensure all feeders/provisions as per HVAC Panel list / SLD has been considered
15.2.12 Supply, Installation, testing & Commissioning of Warm Water Tank of 15M3 Volume for Storage of Condenser Water. Tank to be of IS 2062 construction with epoxy coating. Tank to include inlet and outet connections of 125 NB. Size of tank in rectangular configuration: 4.2M x 1.8M x 2M height Tank to have suitable weather protection for outdoor installation at terrace level. Tank to include the supply and erection of required supports for mounting at terrace level. Complying to the attached technical specifications Nos 1.00 0
15.3 SITC OF PART III : PIPING
15.3A PIPING AND VALVES - CONDENSER SIDE
Note: Centre line Piping measurements will be done. No special additional measurements for all fittings such as Bends, Reducers, Tees, Elbows, etc. The cost for all these items need to be accomodated in running meter rate.
15.3A.1 Supply and Installation of Condenser Water MS Piping as per as per IS 1239 complete with Fittings and Supports Complying to attached technical specifications
15.3A.1.1 300 NB Heavy Rmt 225.00 0
15.3A.1.2 200 NB Heavy Rmt 100.00 0
15.3A.1.3 150 NB Heavy Rmt 25.00 0
15.3A.1.4 100 NB Heavy Rmt 5.00 0
15.3A.1.5 80 NB Heavy Rmt 10.00 0
15.3A.2 Supply and Installation of Valves & Fittings as per Specifications suitable for specified pipe sizes:
15.3A.2.1 Condenser Water Butterfly Valves with body material of Forged Steel / Aluminum Die Cast / ASTM B85-84-383.0, Disc material A351 Gr. CF8M, EPDM 'O' ring spindle seal with PN 16 pressure rating Complying to attached technical specifications
15.3A.2.2 Condenser Water Motorised Butterfly Valves with body material of Forged Steel / Aluminum Die Cast / ASTM B85-84-383.0, Disc material A351 Gr. CF8M, spindle material AISI 410 / 316 , 'O' ring spindle seal with PN 16 pressure rating Note: 230V AC Power supply shall be provided to actuator, Rate should include any provisions required for converting this signal as accepted by actuator Complying to attached technical specifications
15.3A.2.3 Condenser Water Ball Valves with body & bonnet material of Gun Metal / Brass / SS,spindle material SS 304, 'O' ring spindle seal with PN 16 pressure rating Complying to attached technical specifications
15.3A.2.4 Condenser Water Suction Guide cum Strainer with body & cover material of CI 210, flanged connections with SS 80 Mesh, MS or GI guide with PN 16 pressure rating Complying to attached technical specifications
15.3A.2.5 Condenser Water Triple Duty valves with body & cover material of CI 210, valve stem of stainless steel with PN 16 rating Complying to attached technical specifications
15.3A.2.6 Condenser Water Solenoid valves having PN 16 rating. Complying to attached technical specifications
15.3A.2.7 Condenser Water Drain Valves with body material of Forged Steel / Aluminum Die Cast / ASTM B85-84-383.0, Disc material A351 Gr. CF8M, EPDM 'O' ring spindle seal with PN 16 pressure rating Complying to attached technical specifications
15.3A.3 Supply, Installation, testing & Commissioning of Ultasonic Type Flow transmitter suitable for mounting within condenser line of 300 NB rated for up to 10 Bar operating Pressure Complying to attached technical specifications Nos 1.00 0
15.3A.4 Supply and Installation of Three Way Diverting type Valves with Actuator having 4 - 20 mA Input Signal, with Manual Overide Selected for D.P not exceeding 3 Meters. Body material of Cast Iron/ Cast Bronze, Disc material Chrome Nickel Steel, 'O' ring spindle seal with PN 16 pressure rating. Complying to attached technical specifications
15.3A.4.1 Suited for Incoming Flow of 525 CMH and diverting 77 CMH flow to Warm Water Tank & 448 CMH to Cooling Towers against 3-5 m pressure drop Nos 1.00 0
Note: Valve suitable for Incoming Condenser line of 300NB, Warm water line of 125NB and Cooling Tower Line of 300 NB. Required reducers to be considered
15.3B PIPING, INSULATION AND VALVES - PRIMARY SIDE
1) Centre line Piping measurements will be done. No special additional measurements for all fittings such as Bends, Reducers, Tees, Elbows, etc. The cost for all these items need to be accomodated in running meter rate. 2) Insulation thickness for Valves & Fittings shall be the same as the thickness of the pipe on which it is being installed
15.3B.1 Supply and Installation of Antimicrobial / Microban Insulated Primary Side Chilled Water MS Piping as per IS 1239 complete with Fittings and Supports. As per specifications & HVAC Layout
15.3B.1.1 300 NB with 25 mm thick insulation Rmt 75.00 0
15.3B.1.2 200 NB with 25 mm thick insulation Rmt 215.00 0
15.3B.1.3 150 NB with 25 mm thick insulation Rmt 215.00 0
15.3B.1.4 125 NB with 25 mm thick insulation Rmt 165.00 0
15.3B.1.5 100 NB with 25 mm thick insulation Rmt 555.00 0
15.3B.1.6 80 NB with 25 mm thick insulation Rmt 280.00 0
15.3B.1.7 65 NB with 25 mm thick insulation Rmt 270.00 0
15.3B.1.8 50 NB with 25 mm thick insulation Rmt 110.00 0
15.3B.1.9 40 NB with 25 mm thick insulation Rmt 40.00 0
15.3B.1.10 32 NB with 25 mm thick insulation Rmt 150.00 0
15.3B.2 Supply and Installation of Antimicrobial / Microban Insulated Valves & Fittings as per Specifications suitable for below-mentioned pipe sizes:
15.3B.2.1 Chilled Water Insulated Butterfly Valves with body material of Forged Steel / Aluminum Die Cast / ASTM B85-84-383.0, Disc material A351 Gr. CF8M, EPDM 'O' ring spindle seal with PN 16 pressure rating Complying to attached technical specifications
15.3B.2.2 Chilled Water Insulated Motorised Butterfly Valves with body material of Forged Steel / Aluminum Die Cast / ASTM B85-84-383.0, Disc material A351 Gr. CF8M, spindle material AISI 410 / 316 , 'O' ring spindle seal with PN 16 pressure rating Note: 230V AC Power supply shall be provided to actuator, Rate should include any provisions required for converting this signal as accepted by actuator Complying to attached technical specifications
15.3B.2.3 Chilled Water Insulated Non Return Valves with body & cover material of IS 210 Gr. 20, disc material IS 210 Gr. 20 Plastic with PN 16 pressure rating Complying to any related technical specifications provided for this item
15.3B.2.4 Chilled Water Insulated Y' Type Strainer with body material of CI 210 Gr 20 with SS 80 Mesh, PN 16 pressure rating and Complying to attached technical specifications provided for this item
15.3B.2.5 Chilled Water Insulated Ball type Valve with body & bonnet material of Gun Metal / Brass / SS, spindle material SS 304, 'O' ring spindle seal with PN 16 pressure rating Complying to attached technical specifications
15.3B.2.6 Chilled Water Insulated type Suction Guide cum Strainer with body & cover material of CI 210, flanged connections with SS 80 Mesh, MS or GI guide with PN 16 pressure rating Complying to attached technical specifications
15.3B.2.7 Chilled Water Insulated type Triple Duty valves with body & cover material of CI 210, valve stem of stainless steel with PN 16 pressure rating Complying to attached technical specifications
15.3B.3 Supply, Installation, Testing and Commissioning of Drain Valves on Lines 25 NB Ball Type with body & bonnet material of Gun Metal / Brass / SS, spindle material SS 304, 'O' ring spindle seal with PN 16 pressure rating Complying to attached technical specifications related to ball valve. Nos 41.00 0
15.3B.4 Supply, Installation, Testing and Commissioning of Auto Purge Valves to the Highest Point in each chilled water riser (50NB) Nos 4.00 0
15.3B.5 Supply, Installation, Testing and Commissioning of Auto Purge Valves to the Highest Point in AHU chilled water manifold (25NB) Nos 41.00 0
15.3B.6 Supply and Installation of Pressure Independent Two Way Control Valves with Actuator having 4 - 20 mA Input Signal, with Manual Overide, Valve suitable for towards 100% valve authority. Valves to be selected based on below mentioned flow requirement and given pressure drop range of 2 to 3 meters. Valve might be same size or smaller than actual line size of respective AHU. Complying to attached technical specifications
15.3B.7 Supply and Installation of Two Way Control Valves with Actuator having 4 - 20 mA Input Signal, with Manual Overide Selected for D.P not exceeding 3 Meters. Valve authority to be in the range of 0.25 to 0.50. Complying to attached technical specifications
15.3B.7.1 Bypass Line - 150 NB Line Size - Rated for 105 CMH Nos 1.00 0
15.3B.8 Supply, Installation, testing & Commissioning of Ultrasonic Type Flow transmitter for Chilled water Bypass Line Suitable for mounting within 150 NB Dia Chilled Water Piping Line having up to 10 Bar Operating Pressure. Complying to attached technical specifications Nos 1.00 0
15.3B.9 Supply, Installation, testing & Commissioning of Ultrasonic Type Flow transmitter for Chilled water Main Header Line Suitable for mounting within 250 NB Dia Chilled Water Piping Line having up to 10 Bar Operating Pressure. Complying to attached technical specifications Nos 1.00 0
15.3C PIPING, INSULATION AND VALVES - WARM WATER SIDE
1) Centre line Piping measurements will be done. No special additional measurements for all fittings such as Bends, Reducers, Tees, Elbows, etc. The cost for all these items need to be accomodated in running meter rate. 2) Insulation thickness for Valves & Fittings shall be the same as the thickness of the pipe on which it is being installed
15.3C.1 Supply and Installation of Antimicrobial / Microban Insulated Warm Water MS Piping as per as per IS 1239 complete with Fittings and Supports Complying to attached technical specifications. Note : 25 mm Insulation to be provided only on the return line from AHUs
15.3C.1.1 125 NB Heavy 25 mm thick insulation Rmt 110.00 0
15.3C.1.2 125 NB Heavy Rmt 65.00 0
15.3C.1.3 100 NB Heavy 25 mm thick insulation Rmt 155.00 0
15.3C.1.4 100 NB Heavy Rmt 155.00 0
15.3C.1.5 65 NB Heavy 25 mm thick insulation Rmt 245.00 0
15.3C.1.6 65 NB Heavy Rmt 245.00 0
15.3C.1.7 50 NB Heavy 25 mm thick insulation Rmt 100.00 0
15.3C.1.8 50 NB Heavy Rmt 100.00 0
15.3C.1.9 32 NB Heavy 25 mm thick insulation Rmt 10.00 0
15.3C.1.10 32 NB Heavy Rmt 10.00 0
15.3C.2 Supply and Installation of Glass Cloth 160 GSM with Weather Protection Coating Over Warm Water Return Pipe / Valves / Fittings Insulation (Exposed Line)
15.3C.3 Supply and Installation of Antimicrobial / Microban Insulated Valves & Fittings as per Specifications suitable for below-mentioned pipe sizes:
15.3C.3.1 Warm Water Butterfly Valves with body material of Forged Steel / Aluminum Die Cast / ASTM B85-84-383.0, Disc material A351 Gr. CF8M, EPDM 'O' ring spindle seal with PN 16 pressure rating Complying to attached technical specifications
15.3C.3.1.1 125 NB (Non-insulated) Nos 2.00 0
15.3C.3.1.3 65 NB (Non-insulated) Nos 4.00 0
15.3C.3.1.5 50 (NB Non-insulated) Nos 4.00 0
15.3C.3.2 Warm Water Ball Valves with body & bonnet material of Gun Metal / Brass / SS,spindle material SS 304, 'O' ring spindle seal with PN 16 pressure rating Complying to attached technical specifications
15.3C.3.2.3 32 NB (Non-Insulated) Nos 3.00 0
15.3C.3.3 Warm Water Triple Duty valves with body & cover material of CI 210, valve stem of stainless steel with PN 16 rating Complying to attached technical specifications
15.3C.3.3.1 125 NB (Non-Insulated) Nos 2.00 0
15.3C.3.4 Warm Water Drain Valves with body & bonnet material of Gun Metal / Brass / SS,spindle material SS 304, 'O' ring spindle seal with PN 16 pressure rating Complying to attached technical specifications
15.3C.3.4.1 25 NB (Non-Insulated) - Warm Water tank - Drain Nos 1.00 0
15.3C.3.5 Warm Water Y' Type Strainer with body material of CI 210 Gr 20 with SS 80 Mesh, PN 16 pressure rating and Complying to attached technical specifications provided for this item
15.3C.3.5.1 125 NB (Non-Insulated) Nos 2.00 0
15.3C.3.6 Supply and Installation of Three Way Mixing type Valves with Actuator having 4 - 20 mA Input Signal, with Manual Overide Selected for D.P not exceeding 3 Meters. Body material of Cast Iron/ Cast Bronze, Disc material Chrome Nickel Steel, 'O' ring spindle seal with PN 16 pressure rating. Control Valve Authority to be in range of 0.25 to 0.5 Complying to attached technical specifications
15.3C.3.7 Supply, Installation, Testing and Commissioning of Auto Purge Valves to the Highest Point in Warm Water AHU manifold (25NB) Nos 11.00 0
15.3D COMMON ITEMS CONDENSER, CHILLED WATER AND WARM WATER PIPING
15.3D.1 Supply and Installation of 100 mm Dial Type SS Thermometer with Thermowell having SS304/SS316 MOC, Inner and Outer Connection of 1/2" BSP, having stem Length of Min. 150 mm or as per Pipe size and Bore Dia of 13 mm Nos 98.00 0
15.3D.2 Supply and Installation of Pressure Guage, with Barrel Nipple and 6 mm Ball Valve Isolators Nos 108.00 0
15.4 SITC OF PART IV- LOW SIDE AIR-CONDITIONING SYSTEMS WITH CHILLED WATER UNITS | VRV TYPE SYSTEMS
15.4A CHILLED WATER BASED AIR HANDLING UNITS
15.4A.1 Supply, Installation, Testing and Commissioning of Double Skin AHU for Comfort Areas Floor mounted/ Ceiling suspended and of horizontal / vertical / double-decker type and specific size constraints as per tender drawing. with Inlet EU - 4 Filter, CHW Coil of minimum 4-6 Rows as per Coil Conditions specified for Suitable for Coil Conditions Chilled Water Inlet 7°C and Outlet 12°C, UV Lamp for Coil, Plug Fan with VFD or Fan with EC Motor, Having Outlet EU - 8 Filter, Mixing Box (Where Applicable - As per Tender Drawing), RA and FA Dampers, Complying to attached technical specifications for Air Handling Units and having Cooling Capacity and Airflow rate as per below-mentioned requirements:
15.4A.1.1 AHU 1 - 19.5 TR Cooling Capacity, Rated for Air In 24.3°C DB / 17.3°C WB Air Out 11.7°C DB / 11.3°C WB Having Fan rated for 7400 CFM Vs 100 mm SP Nos 1.00 0
15.4A.1.2 AHU 3 - 17.7 TR Cooling Capacity, Rated for Air In 24.4°C DB / 17.5°C WB Air Out 11.7°C DB / 11.3°C WB Having Fan rated for 6500 CFM Vs 100 mm SP Nos 1.00 0
15.4A.1.3 AHU 4 - 27.6 TR Cooling Capacity, Rated for Air In 23°C DB / 17°C WB Air Out 11.7°C DB / 11.3°C WB, Having Fan rated for 11700 CFM Vs 110 mm SP Nos 1.00 0
15.4A.1.4 AHU 5 - 33.2 TR Cooling Capacity, Rated for Air In 23.7°C DB / 16.8°C WB Air Out 11.7°C DB / 11.1°C WB Having Fan rated for 13200 CFM Vs 120 mm SP Nos 1.00 0
15.4A.1.5 AHU 6 - 5.6 TR Cooling Capacity, Rated for Air In 23.8°C DB / 16.9°C WB Air Out 11.7°C DB / 11.2°C WB, Having Fan rated for 2300 CFM Vs 100 mm SP Nos 1.00 0
15.4A.1.6 AHU 9 - 12.5 TR Cooling Capacity, Rated for Air In 25.6°C DB / 17.4°C WB Air Out 11.7°C DB / 11.2°C WB, Having Fan rated for 4600 CFM Vs 100 mm SP Nos 1.00 0
15.4A.1.7 AHU 11 - 33.7 TR Cooling Capacity, Rated for Air In 23.1°C DB / 16.3°C WB Air Out 11.7°C DB / 11.2°C WB, Having Fan rated for 14500 CFM Vs 100 mm SP Nos 1.00 0
15.4A.1.8 AHU 12 - 19.2 TR Cooling Capacity, Rated for Air In 24.6°C DB / 17.1°C WB Air Out 11.7°C DB / 11.2°C WB, Having Fan rated for 7500 CFM Vs 100 mm SP Nos 1.00 0
15.4A.1.9 AHU 14 - 23.6 TR Cooling Capacity, Rated for Air In 24.6°C DB / 17.1°C WB Air Out 11.7°C DB / 11.2°C WB Having Fan rated for 7500 CFM Vs 100 mm SP Nos 1.00 0
15.4A.1.10 AHU 15 - 21.5 TR Cooling Capacity, Rated for Air In 32.5°C DB / 21.8°C WB Air Out 11.7°C DB / 11.4°C WB Having Fan rated for 4200 CFM Vs 100 mm SP Nos 1.00 0
15.4A.1.11 AHU 19 - 6.5 TR Cooling Capacity, Rated for Air In 24.7°C DB / 17.7°C WB Air Out 11.7°C DB / 11.3°C WB, Having Fan rated for 2300 CFM Vs 100 mm SP Nos 1.00 0
15.4A.1.12 AHU 31 - 6.4 TR Cooling Capacity, Rated for Air In 23.8°C DB / 16.9°C WB Air Out 11.7°C DB / 11.2°C WB, Having Fan rated for 2600 CFM Vs 100 mm SP Nos 1.00 0
15.4A.1.13 AHU 23 - 21.8 TR Cooling Capacity, Rated for Air In 24.4°C DB / 17.5°C WB Air Out 11.7°C DB / 11.3°C WB, Having Fan rated for 8100 CFM Vs 100 mm SP Nos 1.00 0
15.4A.1.14 AHU 26A - 13.3 TR Cooling Capacity, Rated for Air In 26.1°C DB / 17.5°C WB Air Out 11.7°C DB / 11.2°C WB, Having Fan rated for 4700 CFM Vs 100 mm SP Nos 1.00 0
15.4A.1.15 AHU 26B - 14.4 TR Cooling Capacity, Rated for Air In 26.5°C DB / 17.5°C WB Air Out 11.7°C DB / 11.2°C WB, Having Fan rated for 5100 CFM Vs 110 mm SP Nos 1.00 0
15.4A.1.16 AHU 26C - 4.3 TR Cooling Capacity, Rated for Air In 25.3°C DB / 17.2°C WB Air Out 11.7°C DB / 11.1°C WB, Having Fan rated for 1600 CFM Vs 100 mm SP Nos 1.00 0
15.4A.1.17 AHU 28 - 8.5 TR Cooling Capacity, Rated for Air In 25.8°C DB / 18.7°C WB Air Out 11.7°C DB / 11.4°C WB, Having Fan rated for 2600 CFM Vs 100 mm SP Nos 1.00 0
15.4A.1.18 AHU 25A - 4.8 TR Cooling Capacity, Rated for Air In 25.7°C DB / 18.5°C WB Air Out 11.8°C DB / 11.3°C WB, Having Fan rated for 1500 CFM Vs 100 mm SP Nos 1.00 0
15.4A.1.19 AHU 25B - 5.8 TR Cooling Capacity, Rated for Air In 24.3°C DB / 17.3°C WB Air Out 11.7°C DB / 11.3°C WB, Having Fan rated for 2200 CFM Vs 100 mm SP Nos 1.00 0
15.4A.1.20 AHU 25C - 9.9 TR Cooling Capacity, Rated for Air In 23.9°C DB / 16.9°C WB Air Out 11.7°C DB / 11.3°C WB Having Fan rated for 3500 CFM Vs 100 mm SP Nos 1.00 0
15.4A.1.21 AHU 25D - 5 TR Cooling Capacity, Rated for Air In 23.9°C DB / 17°C WB Air Out 11.7°C DB / 11.3°C WB, Having Fan rated for 2000 CFM Vs 100 mm SP Nos 1.00 0
15.4A.1.22 AHU 17 - 11.4 TR Cooling Capacity, Rated for Air In 23.9°C DB / 16.9°C WB Air Out 11.7°C DB / 11.2°C WB, Having Fan rated for 4600 CFM Vs 100 mm SP Nos 1.00 0
15.4A.1.23 AHU 29 - 13.2 TR Cooling Capacity, Rated for Air In 23.5°C DB / 16.6°C WB Air Out 11.7°C DB / 11.2°C WB, Having Fan rated for 5600 CFM Vs 100 mm SP Nos 1.00 0
15.4A.2 Supply, Installation, Testing and Commissioning of Double Skin AHU for Critical Areas of the Museum with Temperature and RH Control for Galleries, Related Areas, etc. Floor mounted/ Ceiling suspended and of horizontal / vertical / double-decker type and specific size constraints as per tender drawing. With Inlet EU - 4 Filter, CHW Coil of minimum 4-8Rows as per Coil Conditions specified for Each AHU Suitable for Coil Conditions Chilled Water Inlet 7°C and Outlet 12°C, UV Lamp for Coil, Electric heater as per below mentioned rating, Humidifier as per specified capacity (if applicable and mentioned), Plug Fan with VFD or Fan with EC Motor Outlet EU - 8 Filter, Mixing Box (As Applicable - in Drawing), RA and FA Damper Complying to attached technical specifications for Air Handling Units and having Cooling Capacity and Airflow rate as per below-mentioned requirements:
15.4A.2.1 AHU 20 - 45.1 TR, Cooling Capacity, Rated for Air In 27.3°C DB/ 19.9°C WB Air Out 11.7°C DB / 11.5°C WB, Having Fan Rated for 11600 CFM Vs 115 mm SP, Having Reheaters 6kW X 5 Nos. Nos 1.00 0
15.4A.2.2 AHU 08 - 27.6 TR, Cooling Capacity, Rated for Air In 26.4°C DB / 19.2°C WB Air Out 11.8°C DB / 11.6°C WB, Having Fan Rated for 7500 CFM Vs 115 mm SP, Having Reheaters 6kW X 3 Nos. Nos 1.00 0
15.4A.2.3 AHU 10 - 29.6 TR, Cooling Capacity, Rated for Air In 27°C DB/ 19.7°C WB Air Out 11.7°C DB / 11.4°C WB Having Fan Rated for 7600 CFM Vs 115 mm SP Having Reheaters 5kW X 4 Nos. Nos 1.00 0
15.4A.3 Supply, Installation, Testing and Commissioning of Double Skin AHU for Critical Areas of the Museum with Temperature and RH Control for Galleries, Related Areas, etc. Floor mounted/ Ceiling suspended and of horizontal / vertical / double-decker type and specific size constraints as per tender drawing. With Inlet EU - 4 Filter, CHW Coil of minimum 4-8 Rows as per Coil Conditions specified for Each AHU Suitable for Coil Conditions Chilled Water Inlet 7°C and Outlet 12°C, UV Lamp for Coil, Warm Water Re-heating coil Coils Conditions Warm Water Inlet 25°C and Outlet 20°C as per below mentioned rating, Humidifier as per specified capacity, Plug Fan with VFD or Fan with EC Motor Outlet EU - 8 Filter, (Mixing Box - If applicable as per drawing), RA and FA Damper Complying to attached technical specifications for Air Handling Units and having Cooling Capacity and Airflow rate as per below-mentioned requirements:
15.4A.3.1 AHU 2 - 38.6 TR, Cooling Capacity, Rated for Air In 27.8°C DB/ 20.4°C WB Air Out 11.7°C DB / 11.6°C WB Having Re-Heating Coil Capacity of 27856 kcal/hr. Having Fan Rated for 9100 CFM Vs 100 mm SP Having Humidifier rated for 16 Kg / Hr. Capacity Nos 1.00 0
15.4A.3.2 AHU 27 - 8.2 TR, Cooling Capacity, Rated for Air In 26.1°C DB/ 18.9°C WB Air Out 11.7°C DB / 11.4°C WB, Having Re-Heating Coil Capacity of 6748 kcal/hr, Having Fan Rated for 2400 CFM Vs 100 mm SP Having Humidifier rated for 5 Kg / Hr. Capacity Nos 1.00 0
15.4A.3.3 AHU 7 - 75.3 TR, Cooling Capacity, Rated for Air In 27.8°C DB/ 20.4°C WB Air Out 11.7°C DB / 11.5°C WB, Having Re-Heating Coil Capacity of 55712 kcal/hr., Having Fan Rated for 18200 CFM Vs 120 mm SP, Having Humidifier rated for 31 Kg / Hr. Capacity Nos 1.00 0
15.4A.3.4 AHU 13 - 14.5 TR, Cooling Capacity, Rated for Air In 27.4°C DB/ 20°C WB Air Out 11.7°C DB / 11.5°C WB, Having Re-Heating Coil Capacity of 11326 kcal/hr., Having Fan Rated for 3700 CFM Vs 100 mm SP, Nos 1.00 0
15.4A.3.5 AHU 30 - 12.9 TR, Cooling Capacity, Rated for Air In 26°C DB/ 18.8°C WB Air Out 11.7°C DB / 11.3°C WB, Having Re-Heating Coil Capacity of 11632 kcal/hr., Having Fan Rated for 3800 CFM Vs 100 mm SP Having Humidifier rated for 5 Kg / Hr. Capacity Nos 1.00 0
15.4A.3.6 AHU 18 - 69.4 TR, Cooling Capacity, Rated for Air In 27.1°C DB/ 19.7°C WB Air Out 11.7°C DB / 11.4°C WB, Having Re-Heating Coil Capacity of 55100 kcal/hr., Having Fan Rated for 18000 CFM Vs 115 mm SP Nos 1.00 0
15.4A.3.7 AHU 21A - 45.4 TR, Cooling Capacity, Rated for Air In 27.4°C DB/ 20°C WB Air Out 11.7°C DB / 11.5°C WB Having Re-Heating Coil Capacity of 35203 kcal/hr., Having Fan Rated for 11500 CFM Vs 115 mm SP Nos 1.00 0
15.4A.3.8 AHU 21B - 38.6 TR, Cooling Capacity, Rated for Air In 26.9°C DB/ 19.6°C WB Air Out 11.7°C DB / 11.4°C WB Having Re-Heating Coil Capacity of 31836 kcal/hr., Having Fan Rated for 10400 CFM Vs 115 mm SP Nos 1.00 0
15.4A.3.9 AHU 22 - 55.4 TR, Cooling Capacity, Rated for Air In 27.9°C DB/ 20°C WB Air Out 11.7°C DB / 11.4°C WB, Having Re-Heating Coil Capacity of 42243 kcal/hr., Having Fan Rated for 13800 CFM Vs 115 mm SP Having Humidifier rated for 18 Kg / Hr. Capacity Nos 1.00 0
15.4A.3.10 AHU 16 - 59.9 TR, Cooling Capacity, Rated for Air In 26.1°C DB/ 18.9°C WB Air Out 11.7°C DB / 11.4°C WB, Having Re-Heating Coil Capacity of 51427 kcal/hr., Having Fan Rated for 16800 CFM Vs 115 mm SP Nos 1.00 0
15.4A.3.11 AHU 24 - 61.5 TR, Cooling Capacity, Rated for Air In 25.8°C DB/ 18.6°C WB Air Out 11.6°C DB / 11.3°C WB, Having Re-Heating Coil Capacity of 56779 kcal/hr., Having Fan Rated for 18300 CFM Vs 115 mm SP Having Humidifier rated for 19 Kg / Hr. Capacity Nos 1.00 0
15.4A.4 Supply, Installation, Testing and Commissioning of Humidifiers Suitable for Duct Injection Integrating with Main Supply Duct of respective AHU systems as mentioned and Complying to attached Technical Specifications with following capacity:
15.4A.4.1 AHU 20 - Humidifier rated for 17 Kg / Hr. Capacity Nos 1.00 0
15.4A.4.2 AHU 10 - Humidifier rated for 13 Kg / Hr. Capacity Nos 1.00 0
15.4A.4.3 AHU 13 - Humidifier rated for 6 Kg / Hr. Capacity Nos 1.00 0
15.4A.4.4 AHU 18 - Humidifier rated for 24 Kg / Hr. Capacity Nos 1.00 0
15.4A.4.5 AHU 21A - Humidifier rated for 17 Kg / Hr. Capacity Nos 1.00 0
15.4A.4.6 AHU 21B - Humidifier rated for 13 Kg / Hr. Capacity Nos 1.00 0
15.4A.4.7 AHU 16 - Humidifier rated for 21 Kg / Hr. Capacity Nos 1.00 0
15.4A.5 Supply and Installation of 19 mm Thick Thermal Insulation For Supply & Return Air G.I Duct Complying to attached technical specifications Sqm 10,441.00 0
15.4A.6 Supply and Installation of 25 mm Thick Internal Accoustic Insulation For Initial Supply Air G.I Duct Complying to attached technical specifications Sqm 880.00 0
15.4A.7 Supply and Installation of Extruded Aluminum Powder Coated Plenum Box with 12 mm Fibre Glass Acoustical Insulation and Bottom Operated VCD having, Spigot connection of 200 mm / 250 mm Dia (as per plenum box height). Suitable for connection with Slot Diffusers:
15.4A.7.1 900 mm Length x 150 mm Width x 300 mm Height Nos 38.00 0
15.4A.7.2 900 mm Length x 106 mm Width x 250 mm Height Nos 35.00 0
15.4A.7.3 1000 mm Length x 106 mm Width x 300 mm Height Nos 6.00 0
15.4A.7.4 1000 mm Length x 106 mm Width x 250 mm Height Nos 25.00 0
15.4A.7.5 1000 mm Length x 150 mm Width x 250 mm Height Nos 53.00 0
15.4A.7.6 1000 mm Length x 150 mm Width x 300 mm Height Nos 4.00 0
15.4A.7.7 1200 mm Length x 150 mm Width x 300 mm Height Nos 102.00 0
15.4A.7.8 1200 mm Length x 150 mm Width x 250 mm Height Nos 7.00 0
15.4A.7.9 1200 mm Length x 106 mm Width x 250 mm Height Nos 26.00 0
15.4A.8 Supply and Installation of Extruded Aluminium Manually operated Volume Control Damper having Opposed Blade Type Configuration Complying to attached technical specifications Sqm 50.00 0
15.4A.9 Supply and Installation of Extruded Aluminum Powder Coated Bottom Throw Continuous Slot Diffuser for Supply Air / Return Air having 25mm width for each slot Complying to attached technical specifications
15.4A.9.1 126 mm overall size (2 slot) Rmt 263.00 0
15.4A.9.2 170 mm overall size (3 slot) Rmt 402.00 0
15.4A.10 Supply and Installation of Extruded Aluminum Powder Coated Supply 4 Way Diffuser with Volume Control Damper Complying to attached technical specifications
15.4A.10.1 525 mm x 525 mm listed size Nos 16.00 0
15.4A.10.2 450 mm x 450 mm listed size Nos 55.00 0
15.4A.10.3 375 mm x 375 mm listed size Nos 48.00 0
15.4A.10.4 300 mm x 300 mm listed size Nos 12.00 0
15.4A.10.5 225 mm x 225 mm listed size Nos 4.00 0
15.4A.11 Supply and Installation of Extruded Aluminum Powder Coated Return 4 Way Diffuser Complying to attached technical specifications
15.4A.11.1 525 mm x 525 mm listed size Nos 18.00 0
15.4A.11.2 450 mm x 450 mm listed size Nos 42.00 0
15.4A.11.3 375 mm x 375 mm listed size Nos 48.00 0
15.4A.11.4 300 mm x 300 mm listed size Nos 12.00 0
15.4A.11.5 225 mm x 225 mm listed size Nos 4.00 0
15.4A.12 Supply and Installation of Extruded Aluminum Powder Coated High Ceiling Radial type Swirl Diffuser for Supply air along with Plenum Box, VCD and having 12 to 16 blades and rated for 5M+ vertical throw and 360° flow. Complying to attached technical specifications
15.4A.12.1 Φ 400 mm Dia listed size Nos 205.00 0
15.4A.13 Supply and Installation of Extruded Aluminum Powder Coated Eye Ball type Jet Nozzles having provision for volume control Complying to attached technical specifications
15.4A.13.1 400 mm Dia listed size Nos 40.00 0
15.4A.13.2 325 mm Dia listed size Nos 15.00 0
15.4A.14 Supply and Installation of Extruded Aluminum Powder Coated Rectangular Acoustical Louvers for Return air through critical areas such as galleries, etc., having following sizes and complying to attached technical specifications
15.4A.14.1 5000 mm X 500 mm listed size Nos 1.00 0
15.4A.14.2 2000 mm X 500 mm listed size Nos 1.00 0
15.4A.14.3 1200 mm X 300 mm listed size Nos 1.00 0
15.4A.14.4 2200 mm X 400 mm listed size Nos 2.00 0
15.4A.14.5 2500 mm X 400 mm listed size Nos 1.00 0
15.4A.14.6 3200 mm X 500 mm listed size Nos 2.00 0
15.4A.14.7 3700 mm X 400 mm listed size Nos 1.00 0
15.4A.14.8 5000 mm X 700 mm listed size Nos 1.00 0
15.4A.14.9 1500 mm X 400 mm listed size Nos 1.00 0
15.4A.14.10 3800 mm X 800 mm listed size Nos 1.00 0
15.4A.14.11 4500 mm X 600 mm listed size Nos 2.00 0
15.4A.14.12 5000 mm X 600 mm listed size Nos 1.00 0
15.4A.14.13 5000 mm X 800 mm listed size Nos 3.00 0
15.4A.14.14 4300 mm X 500 mm listed size Nos 2.00 0
15.4A.15 Supply, Installation, Testing and Commisioning of Power Distribution Panel for AHUs System & Related HVAC equipment with incoming Isolator, and Outgoing MCCBs / MCBs, with Intelligent Power Meter for display of Voltages, Current And Power, with Totalizer, Potential free contacts for BMS connectivity of equipment and Voltage sensor suitable for Local / Remote Operation as per all mentioned technical specifications and incoming / outgoing feeders for following panel-wise HVAC equipment: AHU fans, (VFDs as applicable), Door Switch, UV Lamp, Motorized Valves, Dampers, Humdifiers, Electrical Heaters, etc. as applicable per system. Complying to attached technical specifications for electrical panel Refer to HVAC Panel list and SLD for reference of feeders and provisions to be considered per respective panel no. as mentioned below:
15.4A.15.1 HVAC Panel 03 Nos 1.00 0
15.4A.15.2 HVAC Panel 05 Nos 1.00 0
15.4A.15.3 HVAC Panel 06 Nos 1.00 0
15.4A.15.4 HVAC Panel 07 Nos 1.00 0
15.4A.15.5 HVAC Panel 08 Nos 1.00 0
15.4A.15.6 HVAC Panel 09 Nos 1.00 0
15.4A.15.7 HVAC Panel 10 Nos 1.00 0
15.4A.15.8 HVAC Panel 11 Nos 1.00 0
15.4A.15.9 HVAC Panel 12 Nos 1.00 0
15.4A.15.10 HVAC Panel 13 Nos 1.00 0
15.4A.15.11 HVAC Panel 14 Nos 1.00 0
15.4A.15.12 HVAC Panel 15 Nos 1.00 0
15.4A.15.13 HVAC Panel 16 Nos 1.00 0
15.4A.15.14 HVAC Panel 17 Nos 1.00 0
15.4A.15.15 HVAC Panel 18 Nos 1.00 0
15.4A.15.16 HVAC Panel 19 Nos 1.00 0
15.4A.15.17 HVAC Panel 20 Nos 1.00 0
15.4A.15.18 HVAC Panel 21 Nos 1.00 0
15.4A.15.19 HVAC Panel 22 Nos 1.00 0
15.4A.15.20 HVAC Panel 26 Nos 1.00 0
15.4A.15.21 HVAC Panel 27 Nos 1.00 0
15.4A.15.22 HVAC Panel 28 Nos 1.00 0
15.4A.16 Supply, Installation & testing of UL555 rated Motorized Fire & Smoke Damper suitable for duct mounting. Note: 230V AC Power supply shall be provided to actuator, Rate should include any provisions required for converting this signal as accepted by actuator. Dampers to be normally open and should close based on 1) fire signal input 2) Temperature beyond set limit of 74C. Complying to technical specifications attached. Damper with sleeve and having following sizes:
15.4B VRV / VRF SYSTEM BASED AC SYSTEM
15.4B.1 VRV EQUIPMENT
Note : All VRV Systems need to have BMS compatibility for Remote monitoring and control. All software, hardware and provisions required for BMS integration need to be included.
15.4B.1.1 Supply Installation, Testing & Commissioning of modular type Variable Refrigerant Volume air cooled Outdoor units suitable for cooling and heating, having all hermetically sealed inverter type Scroll Compressor(s), microprocessor based Controller, top discharge type condensing unit(s), with R410 A Refrigerant (Or Eco Friendly Green Gas if any), vibration isolators, with suitable foundation, MS Stand for Unit with necessary paint etc. complete as required. The unit shall deliver the rated capacity at AHRI Conditions and work even at 50°C ambient temperature without tripping. The unit shall be suitable to work on 400V +/- 10%, 3 Phase, 50Hz AC power supply. The unit shall be filled with first charge of the refrigerant and ready for use as required. Having COP rating of 3.8 or higher. Complying to attached technical specifications Including System commissioning of VRV system and additional charges of Gas and Compressor oil as required
15.4B.1.1.1 101 KW | 36 HP Cooling Capacity Nos 1.00 0
Note: VRV ODU system to be able to integrate with Below mentioned 4 nos. AHU system DX Coils and Expansion Kits. Any upgradations / changes to the ODU capacity required for the same to be done at no extra cost
15.4B.1.2 Supply, Installation, Testing and Commissioning of Double Skin Ceiling Suspended AHU with specific size constraints as per tender drawing. for Areas of the Museum which require 24 x 7 cooling . Inlet EU - 4 Filter, Dual coil in series: CHW + DX along with expansion kit, CHW Coil to be of minimum 4-8 Rows as per Coil Conditions specified for Each AHU, Chilled Water Inlet 7°C and Outlet 12°C, Minimum 2 nos. Plug fans with Fan providing at least 75 to 100% redundancy even if 1 fan is not working, RA damper if applicable: Complying to attached technical specifications for Air Handling Units
15.4B.1.2.1 AHU for IT Work room - 4.8 TR, Cooling Capacity DX Coil + CHW Coil Fan Rated for 1650 CFM Vs 25 mm SP Nos 1.00 0
15.4B.1.2.2 AHU for Server room - 5.5 TR, Cooling Capacity DX + CHW Coil Fan Rated for 3150 CFM Vs 25 mm SP Nos 1.00 0
15.4B.1.2.3 AHU for UPS Bank room - 9 TR, Cooling Capacity DX + CHW Coil Fan Rated for 5400 CFM Vs 15 mm SP Nos 1.00 0
15.4B.1.2.4 AHU for BMS room - 3.8 TR, Cooling Capacity DX + CHW Coil Fan Rated for 2300 CFM Vs 15 mm SP Nos 1.00 0
15.4B.1.3 Supply & Installation of (Piping Joints) Gas & Liquid Line Pair of Refnets for above mentioned VRV Indoor / Outdoor units as per VRV OEM standard specifications Set 4.00 0
15.4B.1.4 Supply & Installation of Electronic Expansion Kit Suitable for integration of VRV Outdoor Unit with Respective AHU system. Expansion Kit Having follow capacity / configuration:
15.4B.1.4.1 EEV Suitable for 4.8 TR Cooling Load Set 1.00 0
15.4B.1.4.2 EEV Suitable for 5.5 TR Cooling Load Set 1.00 0
15.4B.1.4.3 EEV Suitable for 9 TR Cooling Load Set 1.00 0
15.4B.1.4.4 EEV Suitable for 3.8 TR Cooling Load Set 1.00 0
15.4B.1.5 Supply & Installation of Corded Remote Controller per AHU System Connected to the VRV Outdoor Unit Nos 4.00 0
15.4B.1.6 Supply & Installation of Centralized Remote Controller for VRV Outdoor Unit suitable for integrating all AHU systems (IDUs) and having BMS Connectivity Nos 1.00 0
15.4B.1.7 Supply, Installation & testing of Copper Piping & Fitting for Suction Line with 19 mm thermal Insulation complying to technical specifications for copper piping and copper piping insulation. As per following Pipe sizes:
15.4B.1.8 Supply, Installation & testing of Copper Piping & Fitting for Discharge Line with 13 mm thermal Insulation complying to technical specifications for copper piping and indoor refrigerant piping insulation. As per following Pipe sizes:
15.4B.1.9 Supply & Installation of PVC Drain Piping with 6 mm Nitrile / EPDM Class "O" Insulation, Complying to attached technical specifications. As per following pipe sizes:
15.5 SITC OF PART V : TOILET VENTILATION SYSTEMS
15.5A TOILET VENTILATION
15.5A.1 Supply, Installation, testing & Commissioning of Ceiling Suspended Cabinet type Exhaust Air fans including accessories such as wire mesh, supports, canvas connection, etc. 1. Vendor needs to rework fan static calculation as per actual shop drawing, motors to be IE3 rated or better 2. Kindly consider panel list for bifurcation of single phase and three phase fans Complying to attached technical specifications Fans having the following capacity:
15.5A.1.1 1600 CFM Vs 25 mmwg SP Nos 2.00 0
15.5A.1.2 1700 CFM Vs 25 mmwg SP Nos 1.00 0
15.5A.1.3 2150 CFM Vs 20 mmwg SP Nos 1.00 0
15.5A.2 Supply, Installation, testing & Commissioning of Ceiling Suspended Inline type Exhaust Air fans including accessories such as wire mesh, supports, canvas connection, etc. 1. Vendor needs to rework fan static calculation as per actual shop drawing, motors to be IE3 rated or better 2. Kindly consider panel list for bifurcation of single phase and three phase fans Complying to attached technical specifications Fans having the following capacity:
15.5A.2.1 1100 CFM Vs 20 mmwg SP Nos 1.00 0
15.5A.2.2 900 CFM Vs 20 mmwg SP Nos 1.00 0
15.5A.2.3 600 CFM Vs 20 mmwg SP Nos 3.00 0
15.5A.2.4 200 CFM Vs 20 mmwg SP Nos 1.00 0
15.5A.2.5 600 CFM Vs 20 mmwg SP Nos 1.00 0
15.5A.2.6 400 CFM Vs 20 mmwg SP Nos 2.00 0
15.5A.2.7 1000 CFM Vs 20 mmwg SP Nos 1.00 0
15.5A.2.8 700 CFM Vs 20 mmwg SP Nos 1.00 0
15.5A.2.9 1400 CFM Vs 25 mmwg SP Nos 1.00 0
15.5A.2.10 1300 CFM Vs 20 mmwg SP Nos 1.00 0
15.5A.2.11 1300 CFM Vs 15 mmwg SP Nos 1.00 0
15.5A.3 Supply, Installation, testing & Commissioning of Wall Mounted Type Propeller Exhaust Air fan Fan Complete with any required accessories including weather protective louver compying to attached Technical Specifications for Weather Louver. Fan Dia to be suitable for Exhaust flow up to 100 CFM and for mounting within wall opening of 150mm x 150mm Nos 4.00 0
15.5A.4 Supply & Installation of Circular Exhaust Air Disc Valve in Plastic Construction suitable for Toilet Exhaust with provision for air volume control and complying to attached technical specifications. Having following Sizes:
15.5A.5 Supply & Installation of Extruded Aluminium Powder Coated Non Vision Type Door Louver for Fresh Air / Replacement Air Intake into Toilets / Washrooms Complying to attached technical specifications
15.6 SITC OF PART VI : PRESSURIZATION SYSTEM
Note: Charges for Testing & Commissioning of Staircase and Liftwell Pressurization systems along with required documents to be included within the rates of respective systems. No separate charges will be paid for the same
15.6A STAIRWELL PRESSURIZATION SYSTEM
15.6A.1 Supply, Installation, Testing and Commisioning of Tube Axial Type Fan, Direct Drive Motor with VFD including all required accessories and mounting arrangement as per drawing. Complying to attached technical specifications. Fans to be rated for the following Capacity:
15.6A.1.1 5500 CFM Vs 25 mm swg for ST-01 (Closed + Open Door) Nos 1.00 0
15.6A.1.2 16000 CFM Vs 25 mm swg for ST-01 (Open Door) Nos 1.00 0
15.6A.1.3 5000 CFM Vs 25 mm swg for ST-02 (Closed + Open Door) Nos 1.00 0
15.6A.1.4 18000 CFM Vs 25 mm swg for ST-02 (Open Door) Nos 1.00 0
15.6A.1.5 6000 CFM Vs 25 mm swg for ST-03 (Closed + Open Door) Nos 1.00 0
15.6A.1.6 18000 CFM Vs 25 mm swg for ST-03 (Open Door) Nos 1.00 0
15.6A.1.7 25500 CFM Vs 30 mm swg for ST-E1& ST-E2 (Closed + Open Door) Nos 2.00 0
15.6A.2 Supply, Installation, Testing and Commissioning of Differential Pressure Transmitters for staircase pressurization application, having 0 - 100 Pa or 0 - 10 mm Pressure Range and having output available in 4-20 mA range, Complying to attached technical specifications 2 Nos. DPTs considered per each Staircase. To be placed at the lowest and highest occupied level of each respective stair-well Nos 10.00 0
15.6B LIFT WELL PRESSURIZATION SYSTEM
15.6B.1 Supply, Installation, Testing and Commisioning of Tube Axial Type Fan, Direct Drive Motor including all required accessories and mounting arrangement as per drawing. Complying to attached technical specifications. Fans to be rated for the following Capacity:
15.6B.1.1 5000 CFM Vs 30 mm SWG ( Lift-S1 & S2 ) Nos 1.00 0
15.6B.1.2 3000 CFM Vs 25 mm SWG ( Lift-N2 & N3 ) Nos 2.00 0
15.6B.1.3 4000 CFM Vs 35 mm SWG ( Lift-E3 ) Nos 1.00 0
15.6C COMMON ITEMS FOR STAIRWELL & LIFT WELL PRESSURIZATION
15.6C.1 Supply, Installation, Testing and Commissioning of Power Distribution Panel having Emergency Incoming Power Provision, with Switches Suitable for Outdoor Installation Connectors, Transmitters, By pass Starters, Isolators, with Remote Start/Stop , VFD and Auto / Manual Facility Complying to attaching technical specificatons. Refer HVAC Panel list for list of feeders
15.6C.1.1 HVAC Panel 23 for 5500 CFM & 16000 CFM Pressurization Fans Nos 1.00 0
15.6C.1.2 HVAC Panel 25 for 5000 CFM, 18000 CFM, 6000 CFM, 3000 CFM Pressurization Fans Nos 1.00 0
15.6C.1.3 HVAC Panel 30 for 25500 CFM Pressurization Fans Nos 1.00 0
15.6C.1.4 HVAC Panel 31 for 25500, 4000 CFM Pressurization Fans Nos 1.00 0
15.6C.1.5 HVAC Panel 32 for 5000 CFM Pressurization Fans Nos 1.00 0
15.7 SITC OF PART VII : UTILITY AREA VENTILATION SYSTEMS
15.7A PANEL ROOM & PUMP ROOM VENTILATION
15.7A.1 Supply, Installation, testing & Commissioning of Ceiling suspended Axial type Exhaust Air Fan,with all required mounting (i.e. canvas, wiremesh, supports, etc.) Direct Drive with Motor suitable for 250 ° C X 2 Hrs Rating. Vendor needs to rework fan static calculation as per shop drawing. Motors to be IE3 rated or better. Also check HVAC drawing for any Dia constraints for fan selection in alloted space. Complying to Technical Specifications Attached
15.7A.1.1 26400 CFM Vs 40 mmwg SP Nos 1.00 0
15.7B DG ROOM & PUMP ROOM VENTILATION
15.7B.1 Supply, Installation, testing & Commissioning of Ceiling suspended Axial type Fresh Air Fan,with all required mounting (i.e. wiremesh, supports, etc.) Direct Drive with Motor. Vendor needs to re-work fan static calculation as per shop drawing motors to be IE3 rated or better. Fan outlet speed should not be more than 13 -15m/s. Also check HVAC drawing for any Dia constraints for fan selection in alloted space. Complying to attached technical specifications
15.7B.1.1 46000 CFM Vs 35 mmwg SP Nos 4.00 0
15.7B.2 Supply, Installation, testing & Commissioning of Ductless Induction Ceiling Suspended Ventilation, Dual Speed Jet Fan Assembly suitable for 250 °C X 2 Hrs Rating
15.7B.2.1 400 Φ, 3300CFM (Normal Mode)/ 6600 CFM ( Fire Mode) Nos 2.00 0
15.7C STP PUMP ROOM VENTILATION
15.7C.1 Supply, Installation, testing & Commissioning of Ceiling suspended Axial type Fresh Air Fan,with all required mounting (i.e.wiremesh, supports, etc.) Direct Drive with Motor. Vendor needs to rework fan static calculation as per shop drawing motors to be IE3 rated or better. Fan outlet speed should not be more than 13 -15m/s. Also check HVAC drawing for any Dia constraints for fan selection in alloted space. Complying to attached technical specifications
15.7C.1.1 4100 CFM Vs 25 mmwg SP Nos 1.00 0
15.7C.2 Supply, Installation, testing & Commissioning of Ceiling suspended Axial type Exhaust Air Fan,with all required mounting (i.e.wiremesh, supports, etc.) Direct Drive with Motor suitable for 250° C X 2 Hrs Rating. Vendor needs to rework fan static calculation as per shop drawing motors to be IE3 rated or better. Also check HVAC drawing for any Dia constraints for fan selection in alloted space. Complying to attached technical specifications
15.7C.2.1 4100 CFM Vs 30 mmwg SP Nos 1.00 0
15.7D METERING KIOSK ROOM VENTILATION
15.7D.1 Supply, Installation, testing & Commissioning of Ceiling Suspended Inline type Exhaust Air fans including accessories such as wire mesh, supports, canvas connection, etc. 1. Vendor needs to rework fan static calculation as per actual shop drawing, motors to be IE3 rated or better 2. Kindly consider panel list for bifurcation of single phase and three phase fans Complying to attached technical specifications
15.7D.1.1 800 CFM Vs 15 mmwg SP Nos 1.00 0
15.7D.2 Supply, Installation, testing & Commissioning of Ceiling Suspended Inline type Fresh Air fans including accessories such as wire mesh, supports, canvas connection, etc. 1. Vendor needs to rework fan static calculation as per actual shop drawing, motors to be IE3 rated or better 2. Kindly consider panel list for bifurcation of single phase and three phase fans Complying to attached technical specifications
15.7D.2.1 800 CFM Vs 15 mmwg SP Nos 1.00 0
15.7E PLANT ROOM & ELECTRICAL ROOM VENTILATION
15.7E.1 Supply, Installation, testing & Commissioning of Ceiling suspended Axial type Exhaust air Fan, with all required mounting (i.e. canvas, wiremesh, supports, etc.) Direct Drive with Motor having capacity of motors to be IE3 rated or better. Fan outlet speed should not be more than 13 -15m/s. Also select the fan dia as mentioned in the HVAC drawing. Complying to attached technical specifications
15.7E.1.1 11800 CFM Vs 25 mmwg SP Nos 1.00 0
15.7E.2 Supply, Installation, testing & Commissioning of Ceiling suspended Axial type Fresh air Fan, with all required mounting (i.e. canvas, wiremesh, supports, etc.) Direct Drive with Motor having capacity of motors to be IE3 rated or better. Fan outlet speed should not be more than 13 -15m/s. Also select the fan dia as mentioned in the HVAC drawing. Complying to attached technical specifications
15.7E.2.1 11200 CFM Vs 25 mmwg SP Nos 1.00 0
15.7F PAINT & SPRAY ROOM VENTILATION
15.7F.1 Supply, Installation, testing & Commissioning of Ceiling suspended Axial Fresh air Fan, with all required mounting (i.e. canvas, wiremesh, supports, etc.) with Motor outside of air stream, having capacity of motor to be IE3 rated or better. G-4 filtration required. Additional filtrations if required will be specified at later stage. Complying to attached technical specifications
15.7F.1.1 7300 CFM Vs 25 mmwg SP Nos 1.00 0
15.7F.2 Supply, Installation, testing & Commissioning of Ceiling suspended Axial type Exhaust air Fan, with all required mounting (i.e. canvas, wiremesh, supports, etc.) Direct Drive with Motor having capacity of motors to be IE3 rated or better. Fan outlet speed should not be more than 13 -15m/s. Also select the fan dia as mentioned in the HVAC drawing. Complying to attached technical specifications
15.7F.2.1 3100 CFM Vs 50mmwg SP Nos 1.00 0
15.7G KITCHEN VENTILATION
15.7G.1 Supply, Installation, Testing & Commisioning of Double Skin Direct Stage Evaporative Cooling Unit (Air Washer) with Thermal Break Profile, including Inlet Louvers, EU - 4 Pre - Filter, 300 mm Deep Cellulose Pad Evaporative Cooler, Water Pumps (1 + 1), SS Sump, Plug Fan with VFD or Fan with EC Motor, Motor of IE3 Efficiency or better, Distribution header, Bypass with Valve including Supply air Plenum, In-built Starter Panel & Control. Complying to attached technical specifications for Evaporative Cooling Units and having following capacity :
15.7G.1.1 17500 CFM Vs 75 mm SP Nos 1.00 0
15.7G.2 Supply, Installation, testing & Commissioning of Floor mounted Axial type Fresh Air Fan,with all required mounting (i.e. canvas, wiremesh, supports, etc.) Direct Drive with Motor. Vendor needs to rework fan static calculation as per shop drawing motors to be IE3 rated or better fan outlet speed should not be more than 13 -15m/s. Also select the fan dia as mentioned in the HVAC drawing. Complying to attached technical specifications Having Capacity as follows:
15.7G.2.1 6300 CFM Vs 25 mm SP Nos 1.00 0
15.7G.3 Supply, Installation & Testing of U/V Filters for water in recirculation line for ECU, with isolation and bypass Complying to attached technical specifications
15.7G.4 Supply, Installation & Testing of Clamp On Magnetic Water Conditioners in Make up line. Complying to attached technical specifications
15.7G.5 Supply and Installation of Ball Valve for ECU in Make-up Line 25 NB Dia Complying to attached technical specifications Nos 1.00 0
15.7G.6 Supply, Installation, testing & Commissioning of Floor Mounted Cabinet Exhaust Unit with Electrostatic Precipatator (ESP) for Kitchen Exhaust with all required mounting (i.e. canvas, wiremesh, supports, etc.) SISW Type fan with Belt Drive with Motor outside airstream Vendor needs to rework fan static calculation as per shop drawing motors to be IE3 rated or better With Weather Protective Rating & Canopy for Terrace Mounting Complying to attached technical specifications Unit Having Capacity as follows:
15.7G.6.1 19200 CFM Vs 100 mmwg SP Nos 1.00 0
15.7G.6.2 7150 CFM Vs 50 mmwg SP Nos 1.00 0
15.7H VENTILATION OF OTHER UTILITY AREAS
15.7H.1 Supply, Installation, testing & Commissioning of Wall Mounted Type Propeller Exhaust Air fan Complete with any required accessories including weather protective louver as per weather protective louver technical specifications attached. Fan Dia to be suitable for below mentioned Exhaust flow
15.7H.1.1 1000 CFM Vs. 10mm SP Nos 1.00 0
15.7H.2 Supply, Installation, testing & Commissioning of Ceiling Suspended type Cabinet Exhaust Air Fans, with all required mounting (i.e. canvas, wiremesh, supports, etc.) Direct Drive with Motor. Vendor needs to rework fan static calculation as per shop drawing motors to be IE3 rated or better fanoutlet speed should not be more than 13-15m/s. Also select the fan dia as mentioned in the HVAC drawing.
15.7H.2.1 1600 CFM Vs 25mm wg SP Nos 1.00 0
15.7H.2.2 1700 CFM Vs 25mm wg SP Nos 1.00 0
15.7H.2.3 4650 CFM Vs 20mm wg SP Nos 1.00 0
15.7H.3 Supply, Installation, testing & Commissioning of Ceiling Suspended type Inline Exhaust Air Fans, with all required mounting (i.e. canvas, wiremesh, supports, etc.) Direct Drive with Motor. Vendor needs to rework fan static calculation as per shop drawing motors to be IE3 rated or better fanoutlet speed should not be more than 13-15m/s. Also select the fan dia as mentioned in the HVAC drawing.
15.7H.3.1 300 CFM Vs 15mm wg SP Nos 1.00 0
15.7H.3.2 600 CFM Vs 20mm wg SP Nos 1.00 0
15.7H.4 Supply, Installation, testing & Commissioning of Ceiling Suspended type Cabinet Fresh Air Fans, with all required mounting (i.e. canvas, wiremesh, supports, etc.) Direct Drive with Motor. Vendor needs to rework fan static calculation as per shop drawing motors to be IE3 rated or better fanoutlet speed should not be more than 13 -15m/s. Also select the fan dia as mentioned in the HVAC drawing.
15.7H.4.1 2500 CFM Vs 25 mmwg SP Nos 1.00 0
15.7H.4.2 2100 CFM Vs 25 mmwg SP Nos 2.00 0
15.7H.4.3 6000 CFM Vs 20 mmwg SP Nos 1.00 0
15.7H.4.4 3800 CFM Vs 25 mmwg SP Nos 1.00 0
15.7H.4.5 3800 CFM Vs 15 mmwg SP Nos 1.00 0
15.7H.5 Supply, Installation, testing & Commissioning of Ceiling Suspended type Inline Fresh Air Fans, with all required mounting (i.e. canvas, wiremesh, supports, etc.) Direct Drive with Motor. Vendor needs to rework fan static calculation as per shop drawing motors to be IE3 rated or better fanoutlet speed should not be more than 13 -15m/s. Also select the fan dia as mentioned in the HVAC drawing.
15.7H.5.1 300 CFM Vs 15mm wg SP Nos 1.00 0
15.7H.5.2 150 CFM Vs 15mm wg SP Nos 1.00 0
15.7H.5.3 600 CFM Vs 20mm wg SP Nos 1.00 0
15.7I COMMON ITEM RELATED TO VENTILATION SYSTEMS
15.7I.1 Supply, Installation, testing & Commissioning of Power Distribution Panel for HVAC systems with incoming Isolator, and Outgoing MCBs, with Intelligent Power Meter for display of Voltages, Current And Power, with Totalizer, and Voltage Sensor HVAC Panel to have provison of auto tripping and restart on receipt of fire signal. Certain panels to have provision for both Emergency and Normal Power supply and changover based on actual requirement. Common Outgoing feeders for following HVAC equipment: Feeders including spares and provisions to be cross verified with HVAC Panel List and HVAC Electrical SLD Complying to attached technical specifications.
15.7I.1.1 HVAC Panel 01 Nos 1.00 0
15.7I.1.2 HVAC Panel 04 Nos 1.00 0
15.7I.1.3 HVAC Panel 29 Nos 1.00 0
15.8 PART VIII - COMMON ITEMS ACROSS AC & VENTILATION SYSTEMS
15.8A COMMON AIR DISTRIBUTION ITEMS
15.8A.1 Supply, Installation and testing of G. I. Rectangular Type Ducting with TDC/TDF Flanges, 3M tapes on Joints, Wired Supports with Sesmic Rating suitable for use within Earthquake Zone IV, having intermediate rigid supports, rated for 2" Duct Pressure as per SMACNA 2012 Complying to attached technical specifications for GI Ducting.
15.8A.1.1 24G Thickness Sqm 6,578.00 0
15.8A.1.2 22G Thickness Sqm 4,585.00 0
15.8A.1.3 20G Thickness Sqm 1,361.00 0
15.8A.1.4 18G Thickness Sqm 305.00 0
15.8A.2 Supply & Installation of Extruded Aluminium Powder Coated Weather Louver for Fresh Air, Complying to Technical Specifications Attached | RAL colour need to be coordinated before ordering
15.8A.2.1 1500 X 700 listed size Nos 1.00 0
15.8A.2.2 1600 X 900 listed size Nos 1.00 0
15.8A.2.3 750 X 300 listed size Nos 1.00 0
15.8A.2.4 700 X 300 listed size Nos 2.00 0
15.8A.2.5 400 X 250 listed size Nos 1.00 0
15.8A.2.6 1650 X 800 listed size Nos 2.00 0
15.8A.2.7 1000 X 500 listed size Nos 2.00 0
15.8A.2.8 700 X 500 listed size Nos 1.00 0
15.8A.2.9 300 X 200 listed size Nos 2.00 0
15.8A.2.10 1000 X 600 listed size Nos 1.00 0
15.8A.2.11 1400 X 600 listed size Nos 1.00 0
15.8A.2.12 1500 X 650 listed size Nos 1.00 0
15.8A.2.13 3600 X 1300 listed size Nos 1.00 0
15.8A.2.14 500 X 250 listed size Nos 1.00 0
15.8A.2.15 300 X 150 listed size Nos 1.00 0
15.8A.2.16 1500 X 750 listed size Nos 1.00 0
15.8A.2.17 600 X 250 listed size Nos 1.00 0
15.8A.2.18 1500 X 550 listed size Nos 2.00 0
15.8A.2.19 600 X 350 listed size Nos 1.00 0
15.8A.2.20 1250 X 550 listed size Nos 2.00 0
15.8A.2.21 1700 X 800 listed size Nos 1.00 0
15.8A.3 Supply & Installation of Extruded Aluminium Powder Coated Weather Louver for Exhaust Air, Complying to Technical Specifications Attached
15.8A.3.1 1500 X 700 listed size Nos 1.00 0
15.8A.3.2 750 X 300 listed size Nos 1.00 0
15.8A.3.3 1000 X 500 listed size Nos 1.00 0
15.8A.3.4 1000 X 600 listed size Nos 1.00 0
15.8A.3.5 1000 X 400 listed size Nos 5.00 0
15.8A.3.6 1200 X 400 listed size Nos 1.00 0
15.8A.3.7 1650 X 800 listed size Nos 1.00 0
15.8A.3.8 250 X 200 listed size Nos 1.00 0
15.8A.3.9 400 X 250 listed size Nos 2.00 0
15.8A.3.10 500 X 200 listed size Nos 2.00 0
15.8A.3.11 700 X 500 listed size Nos 1.00 0
15.8A.3.12 1200 X 750 listed size Nos 1.00 0
15.8A.3.13 400 X 200 listed size Nos 1.00 0
15.8A.3.14 500 X 250 listed size Nos 1.00 0
15.8A.3.15 1000 X 350 listed size Nos 1.00 0
15.8A.3.16 600 X 250 listed size Nos 1.00 0
15.8A.3.17 800 X 350 listed size Nos 3.00 0
15.8A.3.18 600 X 300 listed size Nos 1.00 0
15.8A.3.19 750 X 400 listed size Nos 1.00 0
15.8A.4 Supply & Installation of Extruded Aluminium Powder Coated Supply Air Grilles with VCD, Complying to Technical Specifications Attached
15.8A.4.1 700 X 350 listed size Nos 4.00 0
15.8A.4.2 400 X 400 listed size Nos 3.00 0
15.8A.4.3 500 X 500 listed size Nos 4.00 0
15.8A.4.4 600 X 600 listed size Nos 11.00 0
15.8A.4.5 1200 X 150 listed size Nos 3.00 0
15.8A.4.6 1800 X 150 listed size Nos 1.00 0
15.8A.4.7 2400 X 150 listed size Nos 13.00 0
15.8A.4.8 3000 X 150 listed size Nos 21.00 0
15.8A.5 Supply & Installation of Extruded Aluminium Powder Coated Return Air Grilles Complying to Technical Specifications Attached
15.8A.5.1 700 X 350 listed size Nos 4.00 0
15.8A.5.2 400 X 400 listed size Nos 4.00 0
15.8A.5.3 500 x 500 listed size Nos 3.00 0
15.8A.5.4 600 X 600 listed size Nos 12.00 0
15.8A.5.5 300 X 300 listed size Nos 4.00 0
15.8A.6 Supply & Installation of Extruded Aluminium Powder Coated Exhaust Air Grilles Complying to Technical Specifications Attached
15.8A.6.1 400 X 400 listed size Nos 2.00 0
15.8A.6.2 500 X 500 listed size Nos 1.00 0
15.8A.6.3 700 X 350 listed size Nos 24.00 0
15.8A.7 Supply & Installation of Extruded Aluminium Powder Coated Double Deflection Supply Air Grilles with VCD, Complying to Technical Specifications Attached
15.8A.7.1 600 X 600 listed size Nos 22.00 0
15.8A.8 Supply, Installation and testing of Inter connecting Insulated Flexible Circular Ducting Complying to attached technical specifications
15.8B COMMON CABLING & CABLE TRAYS
15.8B.1 Supply, Installation, testing and commissioning of Copper conductor cables XLPE insulated / FRLS multistrand Cu. Conductor armoured / unarmoured cables ( As per IS 1554 & IS 7098) PVC insulated, Multistrand armoured cable of 1.1KV grade with termination glands and identification tags, clamps, and saddles. GI earthing (flats / strips / wires, as may be applicable as per, electric rules : Earthing system shall comply to IS: 3043-1987.)
15.8B.1.1 4C x 1.5 Sqmm YWY Cable Rmt 875.00 0
15.8B.1.2 4C X 2.5 Sq.mm YWY Cable Rmt 350.00 0
15.8B.1.3 4C X 4 Sq.mm YWY Cable Rmt 45.00 0
15.8B.1.4 4C X 6 Sq.mm YWY Cable Rmt 335.00 0
15.8B.1.5 4C X 10 Sq.mm YWY Cable Rmt 235.00 0
15.8B.2 Supply, Installation, testing and commissioning of Aluminium conductor cables XLPE / FRLS multistrand Al. Conductor armoured / unarmoured cables ( As per IS 1554 & IS 7098) PVC insulated, Multistrand armoured cable of 1.1KV grade with termination glands and identification tags, clamps, and saddles. GI earthing (flats / strips / wires, as may be applicable as per, electric rules : Earthing system shall comply to IS: 3043-1987.) ( Vendor to Select Sizes as per Chiller OEM Requirement)
15.8B.2.1 3.5C X 2 runs x 240 Sq.mm. Cable Rmt 70.00 0
*Need to re-check Cable size requirement with Chiller OEM and change the same if required.
15.8B.3 Supply, Installation, Testing and Commissioning of Signal/Sensor Cabling (2Cx1.5 mm Copper FRLS) Complying to attached technical specifications Rmt 13,960.00 0
15.8B.4 Supply, Installation, Testing and Commissioning of Communication Cabling for HVAC BMS and VRV System (2Cx1.5 sqmm Copper FRLS), In 25mm Dia Conduits, UV Stabilized, Complying to attached technical specifications Rmt 20,940.00 0
15.8B.5 Supply & Installation of G. I. Cable Tray with Tray Cover for Chiller Plant and all HVAC System related services as deemed required. Tray to be in GI, perforated type with minimum 14G thickness, equipped with tray cover in external areas (tray cover to be in 14G GI and to have a plain finish) To Comply with Attached Technical Specifications for Cable Tray
Note: Quantity of cable trays have been roughly estimated, same need to be calculated based on finalized cable tray routings within the project
15.8B.5.2 350 mm X 50 mm Rmt 0
15.8C OTHER COMMON ITEMS
15.8C.1 Supply, Installation, Testing and Commissioning of Provision of fire stop mortar system for 250 ° C X 2 Hrs Rating, when tested in accordance with UL 1479/ASTM-E 814 standards, suitable for closing all gaps of penetration for HVAC services passing across fire rated partitions, the mortar assembly shall be light weight and having environmental testing and mold resistance certification / rating Note: Exact quantity requirement for the same is not available at this stage of the project, however, this will need to be provided at all locations where HVAC services are crossing fire rated compartments
15.8C.1.1 Mortar assembly suitable for closure of medium to large size gaps Sqm 150.00 0
15.8C.1.2 Mortar assembly suitable for closure of circular gaps upto 2" Sqm 40.00 0
15.9 PART IX- HVAC BMS
15.9A DDC/ PLC CONTROLLERS
15.9A.1 Supply, Installation, testing & Commissioning of Direct Digital Controllers (DDCs) for Air Handling Systems, Control, Monitoring & Switching On / Off of other respective low-side HVAC Equipment as applicable Complying to technical specifications attached, Refer to HVAC BMS IO Summary for reference of IO points to be covered including the spares requirements per DDC Panels to be provided for housing DDCs along with all internal fitting, equipment, terminals and cabling. DDC to have required provisions for integration with Centralized BMS via BACnet / Modbus
15.9A.2 Supply, Installation, testing & Commissioning of PID Controllers for Pressurization Systems, Control, Monitoring & Switching On / Off as applicable Complying to technical specifications attached Refer to HVAC BMS IO Summary for reference of IO points to be covered including the spares requirements per Pressurization related PID controller PID Controller to have required provisions required for remote monitoring through BMS
15.9A.2.1 PID Controller for Staircase 01, Liftwell S1 & S2 - Pressurization System Set 1.00 0
15.9A.2.2 PID Controller for Staircase 02, 03, Liftwell N2 & N3 - Pressurization System Set 1.00 0
15.9A.2.3 PID Controller for Staircase E1 Pressurization System Set 1.00 0
15.9A.2.4 PID Controller for Staircase E2, Liftwell E3 - Pressurization System Set 1.00 0
15.9A.3 Supply, Installation, testing & Commissioning of Intergated Plant Manager & Optimizer to control chillers, CHW pumps, cond Pumps, Cooling tower fan, on/ off valves and sensors mentioned below: 350 TR X 2 No. Chiller Plant (W) , 350 TR X 1 No. Chiller Plant (S) , Variable Flow Primary Pumps (2W + 1S) , Variable Flow Condenser Pumps (2W + 1S) , 350 TR x 3 nos. Cooling Towers (2W+1S) inclusive of all transmitters and control elements as per Highside P&ID plant manager scope & IO summary HVAC automation system needs to have BACnet IP / Modbus RS485 compatibility. BACnet IP will be preferred as it is an open protocol and having less lag. Complying to attached HVAC Highside PID, BMS HVAC IO Summary for Chiller Plant Set 1.00 0
15.9A.4 Supply, Installation, testing commissioning of Hand Held Operators Terminal for Monitoring all DDC / PLC Automated Control Systems. (1 portable hand-held terminal considered per building. The hand held operator terminal to have display and to be capable for integration with all the controllers in the project Nos 2.00 0
15.9A.5 Supply, Installation, Testing and Commissioning of Hardware and Software for : a) Controllers / PLC, b) Communications, c) SCADA d) Modbus Gateway Complying to applicable technical specifications attached Lumpsum 1.00 0
15.9A.6 Installation, debugging, testing, commissioning, validation and documentation of entire HVAC BMS System inclusive of all above mentioned software, hardware and below mentioned field devices, cabling, etc. Lumpsum 1.00 0
15.9B HVAC TRANSMITTERS - FIELD DEVICES
15.9B.1 Supply, Installation, Testing and Commissioning of Combined Room Mounted Type Air Temp & Relative Humidity Transmitter with temperature range of 0 - 50ºC and RH range of 0 – 100% with required test certificate / field calibration and Complying to attached technical specification Nos 47.00 0
15.9B.2 Supply, Installation, Testing and Commissioning of Outdoor Air Temperature Transmitter 0 - 50ºC with required test certificate / field calibration certificate and Complying to attached technical specifications Nos 1.00 0
15.9B.3 Supply, Installation, Testing and Commissioning of Outdoor Air RH Transmitter 0 – 100% with required test certificate / field calibration certificate and Complying to attached technical specifications Nos 1.00 0
15.9B.4 Supply, Installation, Testing and Commissioning of Water Level Transmitter 0-1000 mm with required test certificate / field calibration certificate and Complying to attached technical specifications Nos 4.00 0
15.9B.5 Supply, Installation, Testing and Commissioning of Pipe Water Temperature Transmitter 0 - 50ºC with required test certification / field calibration certificate and Complying to attached technical specifications Nos 16.00 0
15.9B.6 Supply, Installation, Testing and Commissioning of Pipe Water Pressure Transmitter 0 - 10 kg /cm2 with required test certification / field calibration certificate and Complying to attached technical specifications Nos 10.00 0
15.9B.7 Supply, Installation, Testing and Commissioning of Room Mounted Type Air Temp Transmitter 0 - 50ºC with required test certificate / field calibration and Complying to attached technical specification Nos 19.00 0
15.9B.8 Supply, Installation, Testing and Commissioning of Duct Mounted Type Air Temp Transmitter 0 - 50ºC, with minimum 450 mm Long probe with required test certificate / field calibration and Complying to attached technical specifications Nos 15.00 0
15.9B.9 Supply, Installation, Testing and Commissioning of Duct Mounted Type Air RH Transmitter 0 – 100%, with minimum 450 mm Long probe with required test certificate / field calibration certificate and Complying to attached technical specifications Nos 1.00 0
15.9B.10 Supply, Installation, Testing and Commissioning of AHU Mounted Type Air Temp Transmitter 0 - 50ºC, 450 mm Long Probe (For Coil Off Control) with required test certificate / field calibration and Complying to attached technical specifications Nos 14.00 0
15.9B.11 Supply, Installation, Testing and Commissioning of Air Differential Pressure Switch with adjustable pressure setting, operating temperature range of 0-50ºC and operating pressure up to 250 mm WC, Suitable for high and low trips, having automatic reset provisions Complying to attached technical specifications
15.9B.11.1 Differential Pressure Switch (Across EU-4 Filters) Nos 40.00 0
15.9B.11.2 Differential Pressure Switch (Across EU-8 Filters) Nos 40.00 0
15.9B.12 Supply, Installation, Testing and Commissioning of Air Differential Pressure Transmitters, operating temperature range of 0-50ºC, rated for Differential Pressure Range of 0 - 150 mm for measurement of differential pressure across AHU fan blowers. Complying to attached technical specifications Nos 41.00 0
15.9B.13 Supply, Installation, Testing and Commissioning of IAQ monitors with required test certificate / field calibration certificate and Complying to attached technical specifications *Considered for high density common areas* Nos 20.00 0
TOTAL OF HVAC WORKS 0
16.1 HORTICULTURE
16.1.1 SITE CLEANING
Site cleaning in areas as directed including removing of weed ,cutting grasses , disposing off the material with lead upto 50 m as directed by site incharge etc. complete Sqm 7,125.40 0
16.1.2 MURRUM FILLING
Providing and Filling with Murum in layers to required depths as directed, including watering, ramming and compacting dry density, including carrying out Laboratory 'Proctor Density' Test, etc. complete as directed by site incharge.( Consolidated thickness will be considered for payment.)
16.1.2a Murum available at site within 10m Cum 81.00 0
16.1.2b Murum brought from outside Cum 1.00 0
16.1.3 SURFACE DRESSING
Surface dressing of the ground including removing vegetation and inequalities not exceeding 15 cm deep and disposal of rubbish, lead up to 50m and lift up to 1.5 m.
In All kinds of soil. Sqm 7,517.00 0
16.1.4 LAWN ( Refer point 7.0 from specifications)
Providing & mixing earth & manure as/specification & spreading to a thickness of 300mm. Flooding the ground with water & making kiaries & dismantling the same. Fine dressing the ground to levels specified etc. complete as directed. Planting grass of specified specie as per specification & maintening the same till the grass developes a mat etc complete.
16.1.4a Stenotaphrum secundatum (Excluding grass cost) Sqm 135.00 0
16.1.4b Cynadon dacttylon ( Excluding grass cost) Sqm 46.00 0
16.1.5 SHRUBS, CLIMBERS & GRASSES PLANTATION ON GROUND ( Refer point 6.0 from specifications)
Providing & mixing earth & manure, pesticides as per specification Filling mixture of earth & manure in shrub bed to a specified depth, flooding with water & leveling & Planting. etc complete as directed.( Excluding plant cost )
16.1.5a 600mm depth Sqm 3,586.00 0
16.1.6 FLOWER BED, PERENNIAL PLANTATION ON GROUND ( Refer point 8.0 from specifications)
Providing & mixing earth & manure, Pesticides as per specification Filling mixture of earth & manure in Ground cover bed to a specified depth, flooding with water & leveling & Planting. etc complete as directed.( Excluding plant cost )
16.1.6a 300mm depth Sqm 736.01 0
16.1.7 LAWN, SHRUBS, & GRASSES PLANTATION ON SLAB ( Refer point 9.0 & 9.2 from specifications)
Providing, preparing and filling planting medium as per specification including watering, flooding, dressing, planting as per plan and specification etc.
16.1.7a 200mm depth Sqm 90.00 0
16.1.7b 300mm depth Sqm 600.00 0
16.1.7c 450mm depth Sqm 55.00 0
16.1.7d 600mm depth Sqm 414.00 0
16.1.7e 750mm depth Sqm 141.00 0
16.1.7f 900mm depth Sqm 440.00 0
16.1.8 POTTED PLANTS ( Refer point 9.0 & 9.1 from specifications)
Providing and filling pots with planting media as/specification excluding pot cost, placing as diected, etc complete
16.1.8a 1200mmx500mm and 425mm depth Nos 62.00 0
16.1.8b 700x700mm and 675mm depth Nos 7.00 0
16.1.9 TREES ON GROUND ( Refer point 5.0 from specifications)
Providing & mixing earth & manure, pesticides as per specification Filling mixture of earth & manure in bed to a minimum depth as per pit size flooding with water & leveling,inserting supporting stakes etc complete as directed.( Excluding plant cost )
16.1.10 TREES ON SLAB ( Refer point 9.0 and 9.2 from specifications)
Providing, preparing and filling planting medium as per specification including watering, flooding, dressing, planting as per plan and specification etc.
16.1.11 TRANSPLANTATION OF TREES ( Refer point 10.0 & 11.0 from specifications)
Transplantation of trees within site including excavation around existing tree, pruning of branches, lifting, loading and transportation of existing tree, digging pits for placing tree at new place, adding manure,and, fertilizer, hormones and bio fertilizer to it. Levelled and neatly dressedand disposal of surplus materials from old existing and new sites to designated place. Each tree should be firmly secured to the stake so as to prevent excessive movement, flooding with water, treatment of roots, ropeand gunny bags as per direction of the officer incharge. T&P and all requiredmaterials shall be arranged by the contractor and nothing extra shall bepaid on this account. Girth of tree shall be measured at a height of 1m above ground level.
16.1.11a Girth of trees upto 700MM Nos 140.00 0
16.1.11b Girth of trees beyond 700MM Nos 103.00 0
16.1.12 TREE CUTTING ( Refer point 12.0 from specifications)
Felling trees of the girth (measured at a height of 1 m above ground level),including cutting of trunks and branches, removing the roots and disposal.
16.1.12a Girth of trees upto 700MM Nos 10.00 0
16.1.12b Girth of trees beyond 700MM Nos 16.00 0
16.1.13 SOIL BROUGHT FROM OUTSIDE
Providing and supplying soil on site including loading, unloading, transportation, stacking and protection from rain and contamination, lead upto 300m till use etc. complete
16.1.13a Good red soil for planting Cum 1.00 0
16.1.13b Good poyta soil for planting Cum 1.00 0
16.1.14 MANURE BROUGHT FROM OUTSIDE ( Refer point 2.3 from specifications)
16.1.14a Providing and supplying cow dung manure on site including loading, unloading, transportation, stacking and protection from rain and contamination, lead upto 300m till use etc. complete Cum 1.00 0
16.1.15 JKD EDGING ( Refer point 2.7 from specifications)
16.1.15a Providing & laying JKD make HDPE line edging 150mm in proper line & level including cutting ,fixing etc. complete as directed by site incharge. Rmt 334.30 0
16.1.16 BRICK BAT ( Refer point 2.4 from specifications)
16.1.16a Providing & laying drainage media of 75 mm thick loose brick bat of approved quality including topping with filling crevices with coarse sand about 25 mm above brick bat, etc. complete as directed. Cum 10.00 0
16.1.17 LAYING OF COIR MAT ( Refer point 2.5 from specifications)
16.1.17a For slopes as per design & specification, providing and laying woven Coir Matt of 700 GSM of 1cm X 1 cm grid of approved size, specification and make,in specified area as per drawing, including spreading to line, overlapping, cutting as required, pinning with 8" deep GI/Tor steel clip/pins, etc all complete as directed. Sqm 2,751.00 0
16.1.18 GEOTEXTILE ( Refer point 2.6 from specifications)
16.1.18a Providing & laying 150 GSM Geotextile including cutting, 150mm overlapping ,fixing with 'U' hooks etc. complete as directed Sqm 3,628.00 0
16.1.19 PLANTS ( Refer point 2.1 from specifications)
16.1.19a Providing best quality plants as per specification & plant list including transport, loading, unloading, protection, etc. complete - as per the following list of trees, shrubs, ground covers, climbers and lawn grass
16.1.20.1 SWIETENIA MAHOGANY /SCHLEICHERA OLEOSA Nos 4.00 0
16.1.20.2 MADHUCA LONGIFOLIA Nos 1.00 0
16.1.20.3 DALBERGIA SISSOO Nos 22.00 0
16.1.20.4 ALBIZIA LEBBECK Nos 1.00 0
16.1.20.5 ERYTHRINA INDICA Nos 5.00 0
16.1.20.6 FICUS VIRENS Nos 6.00 0
16.1.20.7 MITRAGYNA PARVIFOLIA Nos 29.00 0
16.1.20.8 ALSTONIA SCHOLARIS Nos 14.00 0
16.1.20.9 COCHLOSPERMUM GOSSYPIUM Nos 5.00 0
16.1.20.10 TABEBUIA AVELLANEDAE Nos 15.00 0
16.1.20.11 TERMINALIA MANTALY Nos 3.00 0
16.1.20.12 PLUMERIA ACUTIFOLIA Nos 1.00 0
16.1.20.13 DALBERGIA LANCEOLARIA Nos 22.00 0
16.1.20.14 ALBIZIA ODORATISSIMA Nos 10.00 0
16.1.20.15 ANOGEISSUS LATIFOLIA Nos 11.00 0
16.1.20.16 PONGAMIA PINNATA Nos 15.00 0
16.1.20.17 BOMBAX CEIBA Nos 6.00 0
16.1.20.18 TERMINALIA ARJUNA/TERMINALIA BELLIRICA Nos 3.00 0
16.1.20.19 CRATAEVA NURVALA Nos 2.00 0
16.1.20.20 FIRMIANA COLORATA Nos 1.00 0
16.1.20.21 WRIGHTIA ARBOREA Nos 17.00 0
16.1.20.22 SARACA ASOCA Nos 4.00 0
16.1.20.23 BAUHINIA ACUMINATA Nos 6.00 0
16.1.20.24 EHRETIA LAEVIS Nos 6.00 0
16.1.20.25 AZADIRACHTA INDICA Nos 11.00 0
16.1.20.26 DENDROCALAMUS STRICTUS Nos 125.00 0
16.1.20.27 BUTEA MONOSPERMA Nos 135.00 0
16.1.20.28 ALANGIUM SALVIIFOLIUM Nos 125.00 0
16.1.20.29 MALLOTUS PHILIPPENSIS Nos 130.00 0
16.1.20.30 BAUHINIA RACEMOSA Nos 157.00 0
16.1.20.31 ALANGIUM SALVIIFOLIUM Nos 137.00 0
16.1.20.32 MALLOTUS PHILIPPENSIS Nos 129.00 0
16.1.20.33 LANNEA COROMANDELICA Nos 12.00 0
16.1.20.34 BOSWELLIA SERRATA Nos 22.00 0
16.1.20.35 MORINDA PUBESCENS Nos 13.00 0
16.1.20.36 ALANGIUM SALVIIFOLIUM/ CRATAEVA NURVALA Nos 22.00 0
16.1.20.37 AEGLE MARMELOS Nos 24.00 0
16.1.20.38 TECOMELLA UNDULATA Nos 13.00 0
16.1.20.39 TECOMA GRANDIS/ TERMINALIA CRENULATA Nos 18.00 0
16.1.20.40 BUTEA MONOSPERMA Nos 20.00 0
16.1.20.41 MORINDA TINCTORIA Nos 21.00 0
16.1.20.42 OROXYLUM INDICUM/ WRIGHTIA ARBOREA Nos 19.00 0
16.1.20.43 AEGLE MARMELOS Nos 21.00 0
16.1.20.44 COCHLOSPERMUM RELIGIOSUM Nos 20.00 0
16.1.20.45 SYZYGIUM CUMINI Nos 116.00 0
16.1.20.46 FICUS RACEMOSA Nos 121.00 0
16.1.20.47 ACACIA NILOTICA Nos 120.00 0
16.1.20.48 DENDROCALAMUS STRICTUS Nos 234.00 0
16.1.20.49 CRATAEVA NURVALA Nos 120.00 0
16.1.20.50 BAMBUSA ARUNDINACEA Nos 122.00 0
16.1.20.51 HOLARRHENA ANTIDYSENTERICA Nos 5.00 0
16.1.20.52 WOODFORDIA FRUTICOSA Nos 86.00 0
16.1.20.53 ALANGIUM SALVIIFOLIUM Nos 3.00 0
16.1.20.54 HELICTERES ISORA Nos 19.00 0
16.1.20.55 BAUHINIA TOMENTOSA Nos 14.00 0
16.1.20.56 VITEX NEGUNDO Nos 29.00 0
16.1.20.57 CASSIA AURICULATA Nos 41.00 0
16.1.20.58 CALOTROPIS PROCERA Nos 29.00 0
16.1.20.59 ADHATODA VASICA Nos 20.00 0
16.1.20.60 PLUMERIA ACUTIFOLIA Nos 11.00 0
16.1.20.61 FICUS SP Nos 6.00 0
16.1.20.62 RADERMACHERA Nos 4.00 0
16.1.21.1 DODONAEA VISCOSA Nos 922.00 0
16.1.21.2 LAWSONIA ALBA Nos 1,393.00 0
16.1.21.3 TABERNAEMONTANA CORONARIA DWARF Nos 397.00 0
16.1.21.4 HIBISCUS ROSA SINENSIS Nos 195.00 0
16.1.21.5 SPHAGNETICOLA TRILOBATA/STENOTAPHRUM SECUNDATUM Nos 1,023.00 0
16.1.21.6 BARLERIA CRISTATA BLUE Nos 94.00 0
16.1.21.7 CYMBOPOGON CITRATUS Nos 1,578.00 0
16.1.21.8 VETIVER ZIZANIOIDES Nos 136.00 0
16.1.21.9 POGONATHERUM PANICEUM Nos 450.00 0
16.1.21.10 CYMBOPOGON NARDUS Nos 144.00 0
16.1.21.11 BARLERIA PRIONITIS Nos 707.00 0
16.1.21.12 MIMOSA HAMATA Nos 162.00 0
16.1.21.13 POGONATHERUM PANICEUM/ PHYLLANTHUS MYRTIFOLIUS Nos 1,991.00 0
16.1.21.14 ANGELONIA ANGUSTIFOLIA/RUELLIA LORENTZIANA Nos 286.00 0
16.1.21.15 DICHANTHIUM ANNULATUM /ACORUS CALAMUS Nos 170.00 0
16.1.21.16 BLUMEA ERIANTHA Nos 297.00 0
16.1.21.17 SIDA ACUTA / TURNERA ULMIFOLIA Nos 198.00 0
16.1.21.18 KALANCHOE BIPINNATA Nos 453.00 0
16.1.21.19 JUSTICIA GENDARUSSA Nos 352.00 0
16.1.21.20 ACORUS CALAMUS/EQUISETUM HYEMALE/THYSANOLAENA LATIFOLIA Nos 440.00 0
16.1.21.21 ABUTILON INDICUM Nos 60.00 0
16.1.21.22 PLUMBAGO ZEYLANICA Nos 429.00 0
16.1.21.23 PENTAS (RED) Nos 162.00 0
16.1.21.24 ANGELONIA GRANDIFLORA Nos 93.00 0
16.1.21.25 VINCA ROSEA ALBA Nos 177.00 0
16.1.21.26 POGONATHERUM CRINITUM Nos 316.00 0
16.1.21.27 CROSSANDRA NIDIBULI FORMIS Nos 28.00 0
16.1.21.28 RULIEA LONDRINA (PURPLE) Nos 69.00 0
16.1.21.29 KALANCHOE PINNATA Nos 41.00 0
16.1.21.30 MURRAYA PANICULATA Nos 380.00 0
16.1.21.31 BAMBUSA MULTIPLEX Nos 44.00 0
16.1.21.32 PHYLLANTHUS MYRTIFOLIUS Nos 447.00 0
16.1.21.33 HYMENOCALLIS LITTORALIS Nos 24.00 0
16.1.21.34 TABERNAEMONTANA CORONARIA Nos 95.00 0
16.1.21.35 VITEX NEGUNDO Nos 239.00 0
16.1.21.36 GREWIA TENAX Nos 555.00 0
16.1.21.37 MAYTENUS EMARGINATA/ HOLARRHENA ANTIDYSENTERICA Nos 258.00 0
16.1.21.38 SACCHARUM MUNJA Nos 3,211.00 0
16.1.21.39 WOODFORDIA FRUTICOSA Nos 13.00 0
16.1.21.40 HELICTERES ISORA Nos 38.00 0
16.1.21.41 GREWIA ASIATICA Nos 27.00 0
16.1.21.42 APLUDA MUTICA Nos 109.00 0
16.1.21.43 SENNA SPECTABILIS Nos 172.00 0
16.1.21.44 GREWIA TENAX/ WOODFORDIA FRUTICOSA Nos 22.00 0
16.1.21.45 CALOTROPIS PROCERA Nos 44.00 0
16.1.21.46 CHRYSOPOGON FULVUS Nos 119.00 0
16.1.21.47 CLERODENDRUM PHLOMIDIS Nos 209.00 0
16.1.21.48 FICUS HISPIDA Nos 230.00 0
16.1.22 CLIMBERS
16.1.22.1 VENTILAGO DENTICULATA Nos 43.00 0
16.1.22.2 CLEMATIS HEDYSARIFOLIA Nos 31.00 0
16.1.22.3 LONICERA JAPONICA Nos 8.00 0
16.1.22.4 IPOMOEA/THUMBERGIA LAURIFOLIA Nos 39.00 0
16.1.22.5 ARGYREIA NERVOSA Nos 54.00 0
16.1.22.6 COMBRETUM ALBIDUM Nos 180.00 0
16.1.22.7 TINOSPORA CORDIFOLIA Nos 38.00 0
16.1.22.8 WATTAKAKA VOLUBILIS Nos 9.00 0
16.1.22.9 CRYPTOLEPIS DUBIA Nos 8.00 0
16.1.22.10 CELASTRUS PANICULATUS Nos 8.00 0
16.1.22.11 IPOMOEA MARGINATA Nos 9.00 0
16.1.22.12 DALBERGIA VOLUBILIS Nos 8.00 0
16.1.22.13 FICUS PUMILA Nos 22.00 0
16.1.22.14 VENTILAGO MADRASPATANA Nos 7.00 0
16.1.23 GRASSES
16.1.23.1 ARACHIS PINTOI Nos 4,250.00 0
16.1.23.2 ACORUS CALAMUS/ANGELONIA Nos 902.00 0
16.1.23.3 PENNISETUM PANICULATUM/ EQUISETUM Nos 869.00 0
16.1.24.1 STENOTAPHRUM SECUNDATUM Sqm 312.00 0
16.1.24.2 CYNODON DACTYLON Sqm 960.00 0
TOTAL OF HORTICULTURE WORKS 0
16.2 IRRIGATION WORK 0.00
16.2.1 Providing, laying & jointing in position HDPE pipe (PE 100) conforming to ISI S : 4984 / 2000 and suitable for the respective working pressures with all butt welded fittings and accessories e.g. couplings, tees, bends, reducers, screwed adapters, flanged tail pieces etc. jointing as per manufacturers' instruction,etc. item complete.
16.2.1.1 HDPE Pipe 90 mm-10 kg/cm2 Rmt 1,300.00 0
16.2.1.2 HDPE Pipe 75 mm-10 kg/cm2 Rmt 600.00 0
16.2.2 Providing, laying, jointing, testing and commissioning of approved make Agriculture PVC Pipes Confirming to IS 4985:2000 laid in wall / on floor / below ceiling in shortlengths for wash hand basin / kitchen sinks to floor trap, including all required PVC fittings as per IS 7834:1987 such as 45⁰ bend / shoe bend, single Y, 87.5° bend, socket, reducer etc. with materials & labour etc. complete, jointing with approved make solvent cement solution & giving watertightness test for pipes laid in the sunken / ceiling portion with making holes in walls / floor grooving & redoing the same and proper clamp / hangers / pedistal supports wherever required necessary etc. complete, as per direction of engineer in charge.
16.2.2.1 PVC pipe 75mm-6 kg/cm2 Rmt 18.00 0
16.2.2.2 PVC pipe 63mm-6 kg/cm2 Rmt 846.00 0
16.2.2.3 PVC pipe 50mm-6 kg/cm2 Rmt 624.00 0
16.2.2.4 PVC pipe 40mm-6 kg/cm2 Rmt 786.00 0
16.2.3 Providing laying and jointing in true line and level U.P.V.C. Pipe (SCH-40) for cold water including fittings as approved by Engineer In Charge. Pipe shall be fixed on the wall with the help of clamp at every two metre C/C or shall be concealed as directed including necessary fittings etc. including testing of pipe and joints and fixing the same with adhesive solvent, including cost of all materials.
16.2.4 DRIP & SPRINKLER IRRIGATION & ACCESSORIES
16.2.4.1 Providing & fixing, testing & commissioning of PC inline polytube having 16mm dia & 0.40-0.45 mtr spacing of dripper, 3.4-4.0 LPH discharge with all necessary fittings like take off, gromet, connectors, tees, elbows, end caps etc as required and specified complete (Class II ) Rmt 6,500.00 0
16.2.4.2 Providing & fixing, testing & commissioning of Subsurface PC inline polytube having 16mm dia & 0.40-0.45 mtr spacing of dripper, 3.4-4.0 LPH discharge with all necessary fittings like take off, gromet, connectors, tees, elbows, end caps etc as required and specified complete Rmt 300.00 0
16.2.4.3 Providing & fixing, testing & commissioning of plain polytube having 16mm dia with all necessary fittings like take off, gromet, connectors, tees, elbows, end caps etc as required and specified complete (Class II ) Rmt 18,000.00 0
16.2.4.4 Providing & fixing of Tie Down Stake 15 Cm, Galvanized Steel 9 Gauge Nos 12,400.00 0
16.2.4.5 Providing & fixing of PC Drippers 8lph Nos 30,000.00 0
16.2.4.6 Providing & fixing, testing & commissioning of Pro-spray pop-up sprinkler with Rotary/ MP Rotator nozzle having radius varies from the 4 to 10 mtr along with the check valve with PRS Nos 50.00 0
16.2.4.7 Providing & fixing, testing & commissioning of Pro-spray pop-up with spray nozzle having radius varies from 2- 5 mtr along with the check valve with PRS Nos 50.00 0
16.2.4.8 Providing & fixing, testing & commissioning of Swing Joint Assembly / Shrub Riser assembly 1/2" Size Nos 100.00 0
16.2.5 VALVES & VALVE BOXES
Supplying, fixing, testing and commissioning of butterfly valve of PN 1.6 rating with bronze/gunmetal seat duly ISI marked complete with nuts, bolts, washers, gaskets conforming to IS 13095 of following sizes as required :
16.2.5.1 Butterfly Valve 80 mm as Isolation valve - 3" Nos 9.00 0
16.2.5.2 Butterfly Valve 65 mm as Control valve - 2.5" Nos 14.00 0
Providing, fixing, tseting, commisioing of PVC Ball valve valves of suitable size as per specifications including the cost of all fittings & accessories complete
16.2.5.3 Ball Valve 63 MM Nos 9.00 0
16.2.5.4 Ball Valve 50 MM Nos 8.00 0
16.2.5.5 Providing, fixing, testing, commisioing of 40/50 mm PVC Flush valves of suitable size as per specifications including the cost of all fittings & accessories complete Nos 17.00 0
16.2.5.6 Providing & fixing, testing & commissioning of a 1" Aluminium Air cum vaccum valve. The Air release valve shall be capable of both releasing and admitting air from and into the line. The working pressureshall be 5 bar. Including MS service saddle and riser assembly Nos 6.00 0
16.2.5.7 Providing & fixing, testing & commissioning of 12" Rectangular Valve box with greenlid andcorrugated structure with unique shovel access slot and bolt hole knockout. etc. item complete. Nos 23.00 0
16.2.5.8 Providing & fixing, testing & commissioning of 10"Round box with greenlid andcorrugated structure with unique shovel access slot and bolt hole knockout. etc. item complete. Nos 17.00 0
16.2.5.9 Providing & fixing, testing & commissioning of 6"Round box with greenlid andcorrugated structure with unique shovel access slot and bolt hole knockout. etc. item complete. Nos 38.00 0
16.2.5.10 Providing & fixing, testing & commissioning of Brass Quick coupling valve 3/4" made up ofsolid brass with locking cover corrosion resistant and stainless steel spring. Including service saddle and riser assembly. etc. item complete. Nos 32.00 0
16.2.5.11 Providing & fixing, testing & commissioning of Brass Key threads into top of QCV to provide water access And Brass Swivel Elbow. etc. item complete. Nos 10.00 0
FILTERATION UNIT
16.2.6 Providing & fixing, testing & commissioning of Autobackwash filtration unit screen filter having capacity 25 m3/hr with necessary fittings & accessories etc complete Nos 1.00 0
16.2.7 PUMPING UNIT
16.2.7.1 Providing & fixing, testing & commissioning of Monoblock / Openwell submersible pumpset of having discharge 5 lps@ 75-80 mtr head etc. item complete. Pump Set (1 Working + 1 Standby) Nos 2.00 0
16.2.7.2 Providing & fixing, testing & commissioning of outdoor control panel suitable for pumpset having outdoor type panel box and fixed alongwith following accessories starter ,start / stop push buttons , Ammeter, Voltmeter , Indicating lamps, MCB , with cable, auto manual relay etc. item complete.( Two in ONe) with stand Nos 1.00 0
16.2.7.3 Providing & fixing, testing & commissioning of Submesible Cable required for pumping system 4 sq. mm x 3 core Rmt 100.00 0
16.2.7.4 Providing & fixing, testing & commissioning of control Valve /Butterfly Valve in mainline for bypass and flow diversion of approved quality 3" size with necessary fittings & accessories etc. complete. Nos 1.00 0
Providing, installation, testing and commissioning of non-return valve of following sizes confirming to IS: 5312 complete with rubber gasket, GI bolts, nuts, washers etc.as required
16.2.7.7 Providing & fixing, testing & commissioning of Plastic Pressure Relief Valve 2" etc. with necessary fittings & accessories etc complete. Nos 1.00 0
Providing, fixing, testing & commisioning of approved make Digital water meter (BMS Compatible) including JT 121PP Sensor With 0.2 Mtr Wire & SS304 stub end with MS flange "T" fitting for following sizes. The cost also include all the jointing materials etc., complete as required.
16.2.7.8 80mm dia. Water pipe connection Nos 1.00 0
16.2.8 AUTOMATION EQUIPMENT
16.2.8.1 Providing & fixing, testing & commissioning of Direct burial 14 AWG x 2 C Decoder cable for two way communication between decoder controller and decoders complete. etc. item complete. Rmt 1,600.00 0
16.2.8.2 Providing & fixing, testing & commissioning of HDPE conduit Pipe complete 32 mm, PE 80 Rmt 1,600.00 0
16.2.8.3 Providing & fixing, testing & commissioning of ACC2 decoder contoller, outdoor mount with 230/240 VAC internal transformer decoder control system ,turf decoders and line surge protectors with options of program BACK UP AND RESTORE , cycle +soak, Rain delay, SOLARSYNC Mini weather station, controlling upto 225 working station wiyh 8 station block programming ,built in SD card reader with centralus software with required LAN connection module, cable etc complete Nos 1.00 0
16.2.8.4 Providing & fixing, testing & commissioning of Single station decoder with surge suppression and ground wire Model : ICD 100 Nos 31.00 0
16.2.8.5 Providing & fixing, testing & commissioning of 2" Solenoid globe Valves with fabric reinforced diaphram and rugged PVC construction,compatible with and slow closing to prevent water hammer,pressure rating upto 10 bar with 24AC solenoid, with provision to attach Pressure Regulator. etc. item complete. Nos 23.00 0
16.2.8.6 Providing & fixing, testing & commissioning of 1.5" Solenoid globe Valves with fabric reinforced diaphram and rugged PVC construction,compatible with and slow closing to prevent water hammer,pressure rating upto 10 bar with 24AC solenoid, with provision to attach Pressure Regulator. etc. item complete. Nos 8.00 0
16.2.8.7 Providing & fixing, testing & commissioning of10" Round box for solenoid valves with greenlid andcorrugated structure with unique shovel access slot and bolt hole knockout. etc. item complete. Nos 31.00 0
16.2.8.8 Providing & fixing, testing & commissioning of ACCU-SYNC-ADJ ACCU-SYNC PRESSURE REGULATOR, ADJUSTABLE PRESSURE MODEL 1.4–7 BAR (20–100 PSI), etc. item complete. Nos 31.00 0
16.2.8.9 Providing & fixing, testing & commissioning of direct bury -on wire connector with strain relief , with waterproof silicon sealant.etc. item complete. Nos 200.00 0
16.2.8.10 Supply and fixing of copper grounding rod 8 ft x 5/8" , clamps, charcoal and all requisite accessories complete. etc. item complete. Nos 6.00 0
16.2.8.11 Supplying, Fixing, Testing & Commissioning of wireless Solar Sync ET Sensor with in-built Rain Sensor with latching bracket & extension cables enclosed in suitable dia of approved make pvc conduit pipe clamped to wall, connecting the Irrigation Controller, etc., complete Nos 1.00 0
16.2.8.12 Supply & Installation of Bridge FS-QS-1220 QuickServer Enhanced Gateway, Hunter Industries Protocol Driver to Modbus RTU/TCP or BACnet IP/MSTP, FieldServer to serve a maximum of 500 points. (The Gateway will be an active client in communications with the Hunter controller. The gateway will issue messages to read/write data. The Hunter Controller will be a passive server, waiting silently for messages from the gateway to which it will respond. The data read will be cached for serving via a 2nd protocol such as DNP3 to Cimplicity or Modbus / BACnet for a building management system. Any of the over 140 protocols in the gateway library may be connected to the Hunter Driver.) 1.00 0
16.2.8.13 Supplying, Fixing, Testing & Commissioning of wired 3" Flow Sensor with sensor decoder with six blade impeller ,programablefrom computer with accuracy + or - 1%,flow rate 0.5-30feet per sec with 100psi max pressure ,temp upto 60degree centigrade with transmitter with extension wire, etc.,complete Nos 1.00 0
16.2.9 RCC SLEEVES
Providing laying (to level or slopes) and jointing reinforced concrete Light duty non-pressure pipes I.S. class NP2 of the following internal diameter with collars and butt ends prepared for collar joints including testing of joints complete.
TOTAL OF IRRIGATION WORKS 0
16.3 WATERBODIES
16.3.1 Water Body - I
16.3.1.1 TOTALLY NON-CORROSIVE Bobinwound Filter made of Fibreglass with filteration bed depth of 0.5m. Fitted with collector arms and diffusers made from unplasticised PVC and PP. Filter Diameter 650 mm. MPV Connection: 1.5" Working pressure 2.5kg/cm2, (37.5 PSI), Test pressure 3.75 kg/cm2 (56.25 PSI). Flow rate of 10m³/hour at a specific velocity of 30m³/hr/m². Filter to be supplied complete with lid in polyester resin and fibre glass manual air purge cap, port for sand discharge. Nos 1.00 0
16.3.1.2 Multiport valve 6 way with 1.5" connection to Filter for 5 separate operations. Nos 1.00 0
16.3.1.3 Activated Filter Media © Primarily gives best filtration results, Reduces Backwash, Saves filtered water and has non-biofilming property with life time shelf life for the media. Size: Grade1(80%) Grade2(20%) Lumpsum 1.00 0
Make : Dryden Aqua, Switzerland
16.3.1.4 Filtration Pump: Energy Efficient Self Priming Pump Made from high-temperature engineered thermo-plastic to withstand extreme heat and prevent corrosion. High-grade stainless steel motor shaft. Flow rate 10 m3/hr @8 mtrs head with inbuilt prefilter strainer Capacity 0.75 hp, 2850 rpm, 400 volts (1W+1S) Nos 2.00 0
16.3.1.5 Cascade Fall Pump: Energy Efficient Self Priming Pump Made from high-temperature engineered thermo-plastic to withstand extreme heat and prevent corrosion. High-grade stainless steel motor shaft. Flow rate 50 m3/hr @ 10 mtrs head with inbuilt prefilter strainer Capacity 5.0 hp, 2850 rpm, 400 volts (2W+1S) Nos 3.00 0
16.3.1.6 Combined Photocatalytic and Hydroxyl Radical technology disinfection system for sanitisation of recirculating pond water; the most powerful, proven oxidiser. Hygienic, sterile pool water that sparkles to be installed after the sand filter with Dosage of 84mj/cm2 @ flow rate of 10m3/hr, Lamp: Low Pressure / High Output Double Tube : 2x55W, Lamp Life:14,000 hrs. Nos 2.00 0
Make : ELECRO/Quantum
16.3.1.7 Floating Dispenser for Chlorine Nos 1.00 0
16.3.1.8 Floor inlet in Black ABS plastic with max flowrate 0-12m3/hr with 50 mm glue connection Nos 35.00 0
16.3.1.9 Vacuum point in Black ABS plastic for suction sweeper with 2" connection Nos 2.00 0
16.3.1.10 Rigid PVC wall conduit with Flange for Vacuum point non-threaded 2" Nos 2.00 0
16.3.1.11 Round/Square Drain grill VGB Anti-Vortex Nos 2.00 0
16.3.1.12 Anodised Extruded Aluminum fixed with clip type connection 1-1/2" Nos 1.00 0
16.3.1.13 Reinforced telescopic Handle 3.6-7.2 mtrs long Nos 1.00 0
16.3.1.14 Floating suction ,made of polyethyene blue color Ø40 mm(1-1/2") 10 mtrs long Nos 1.00 0
16.3.1.15 Leaf net (deep)-clip type Nos 1.00 0
16.3.1.16 Leaf net (flat) clip type Nos 1.00 0
16.3.1.17 Curved brush clip type Nos 1.00 0
16.3.1.18 Test kit for pH and chlorine Nos 1.00 0
16.3.1.19 Algae Brush SS Bristles Nos 1.00 0
16.3.1.20 Straight Brush clip type Nos 1.00 0
16.3.1.21 Foam Jets: Cast Bronze Conical shaped Foam Fountain jets for good aerated display with 1m fountain height. Connection 1" with 157mm height and 50mm orifice. Flow rate of 100 lpm per nozzle @ 3m head. MOC:Bronze/Brass Nos 19.00 0
16.3.1.22 Foam Jet Pump: Energy Efficient Self Priming Pump Made from high-temperature engineered thermo-plastic to withstand extreme heat and prevent corrosion. High-grade stainless steel motor shaft. Flow rate 56m3/hr @ 8 mtrs head with inbuilt prefilter strainer Capacity 5.0 hp, 2850 rpm, 400 volts (2W+0S) Nos 2.00 0
16.3.1.23 Ball Valve Solvent type Ø 50 mm Nos 2.00 0
16.3.1.24 Ball Valve Solvent type Ø 63 mm Nos 6.00 0
16.3.1.25 Butterfly Valve Solvent type Ø 75 mm Nos 6.00 0
16.3.1.26 Butterfly Valve Solvent type Ø 90 mm Nos 8.00 0
16.3.1.27 Butterfly Valve Solvent type Ø 110 mm Nos 9.00 0
16.3.1.28 Non-Return Valve Spring type Ø 63 mm Nos 2.00 0
16.3.1.29 Non-Return Valve Wafer type Ø 75 mm Nos 3.00 0
16.3.1.30 Non-Return Valve Wafer type Ø 90 mm Nos 7.00 0
16.3.1.31 Non-Return Valve Wafer type Ø 110 mm Nos 3.00 0
Make : PIMTAS/Hidroten/Coroplas
uPVC Piping with complete fittings of 10 bar ISI mark Grey color pipe
16.3.1.32 Ø 75 mm (Main Drain) x 2 separate pipes Rmt 114.00 0
16.3.1.33 Ø 63 mm (Vacuum Point) to Suction Header Rmt 60.00 0
16.3.1.34 Ø 50 mm (Filter to Main Pool Return inlet) & Ø 63 mm (PHO) Rmt 72.00 0
16.3.1.35 Ø 63 mm (Pump Suction) for Filtration Rmt 12.00 0
16.3.1.36 Ø 50 mm (Pump Delivery) for Filtration Rmt 12.00 0
16.3.1.37 Ø 63 mm Balancing Tank to Pump Suction Header) Filtration Rmt 12.00 0
16.3.1.38 Ø 160 mm x 2nos (Pump Suction) for Fountain jets Rmt 12.00 0
16.3.1.39 Ø 110 mm x 2nos (Pump Delivery) for Fountain jets Rmt 114.00 0
16.3.1.40 Ø 160 mm x 2nos (Pump Suction) for Cascading Fall Rmt 12.00 0
16.3.1.41 Ø 110 mm x 2nos (Pump Delivery) for Cascading Fall Rmt 164.00 0
16.3.1.42 Ø 180mm Suction Header (Fountain) Rmt 6.00 0
16.3.1.43 Ø 180mm Suction Header (Cascade) Rmt 6.00 0
16.3.1.44 Ø 110mm Delivery Header (Fountain) Rmt 6.00 0
16.3.1.45 Ø 110mm Delivery Header (Cascade) Rmt 6.00 0
16.3.1.46 Ø 200mm Overflow Pipe Rmt 72.00 0
Make : Prince/Supreme/Finolex
16.3.1.48 Pipe support for ceiling Rmt 30.00 0
Electrical Cable & Conduits with screws and clamp
16.3.1.49 2 core 2.5 mm2 flex-PVC FRLS copper cable Rmt 90.00 0
16.3.1.50 3 core 2.5 mm2 flex-PVC FRLS copper cable Rmt 40.00 0
16.3.1.51 3 core 4 mm2 flexible PVC FRLS copper cable Rmt 30.00 0
16.3.1.52 4 core 4 mm2 flexible PVC FRLS copper cable Rmt 30.00 0
16.3.1.53 Conduits for Cable Rmt 200.00 0
Make : Cable & Conduits -KEI/Polycab
Perforated Pre-galvansided Cable tray 1.6 mm thick for Pumps
Electrical Panel
16.3.1.55 Complete Electrical Panel with CRCA sheet with 14 Gauge with VAF meter, IP42 . Phase indicator lamps , MCB for ( 02 nos.) with indicator lamp with on/off button with selector switch for manual/Auto mode, MCB for recirculation pumps ( 02+03=05 nos.),PHO system (02 nos) RCCB( 30 mA), Heater for Panel ,Exhaust fan for fresh air in the Panel with Potential contact free and Timer for Pumps Nos 1.00 0
uPVC Puddle Flange/Sleeves
16.3.1.63 Labour, Supervision, Erection & Commissioning Lumpsum 1.00 0
16.3.2 Water Body - II
16.3.2.1 TOTALLY NON-CORROSIVE Bobinwound Filter made of Fibreglass with filteration bed depth of 0.5m. Fitted with collector arms and diffusers made from unplasticised PVC and PP. Filter Diameter 700 mm. MPV Connection: 1.5" Working pressure 2.5kg/cm2, (37.5 PSI), Test pressure 3.75 kg/cm2 (56.25 PSI). Flow rate of 11.5m³/hour at a specific velocity of 30m³/hr/m². Filter to be supplied complete with lid in polyester resin and fibre glass manual air purge cap, port for sand discharge. Nos 1.00 0
16.3.2.2 Multiport valve 6 way with 1.5" connection to Filter for 5 separate operations. Nos 1.00 0
16.3.2.3 Activated Filter Media © Primarily gives best filtration results, Reduces Backwash, Saves filtered water and has non-biofilming property with life time shelf life for the media. Size: Grade1(80%) Grade2(20%) Lumpsum 1.00 0
Make : Dryden Aqua, Switzerland
16.3.2.4 Filtration Pump: Energy Efficient IE3 Motor Self Priming Pump Made from high-temperature engineered thermo-plastic to withstand extreme heat and prevent corrosion. High-grade stainless steel motor shaft. Flow rate 11.50 m3/hr @10 mtrs head with inbuilt prefilter strainer Capacity 1.0 hp (0.75kw), 2850 rpm, 400 volts (1W+1S) Nos 2.00 0
Make : Pentair or Equivalent
16.3.2.5 Cascade Fall Pump: Energy Efficient Self Priming Pump Made from high-temperature engineered thermo-plastic to withstand extreme heat and prevent corrosion. High-grade stainless steel motor shaft. Flow rate 50 m3/hr @8 mtrs head with inbuilt prefilter strainer Capacity 5.0 hp, 2850 rpm, 400 volts (1W+1S) Nos 2.00 0
Make : Pentair or Equivalent
16.3.2.6 Combined Photocatalytic and Hydroxyl Radical technology disinfection system for sanitisation of recirculating pond water; the most powerful, proven oxidiser. Hygienic, sterile pool water that sparkles to be installed after the sand filter with Dosage of 73mj/cm2 @ flow rate of 14m3/hr, Lamp: Low Pressure / High Output Double Tube : 2x55W, Lamp Life:14,000 hrs. Nos 1.00 0
Make : ELECRO/Quantum
16.3.2.7 Floating Dispenser for Chlorine Nos 1.00 0
16.3.2.8 Floor inlet in Black ABS plastic with max flowrate 0-12m3/hr with 50 mm glue connection Nos 26.00 0
16.3.2.9 Vacuum point in Black ABS plastic for suction sweeper with 2" connection Nos 2.00 0
16.3.2.10 Rigid PVC wall conduit with Flange for Vacuum point non-threaded 2" Nos 2.00 0
16.3.2.11 Round/Square Drain grill VGB Anti-Vortex Nos 5.00 0
16.3.2.12 Anodised Extruded Aluminum fixed with clip type connection 1-1/2" Nos 1.00 0
16.3.2.13 Reinforced telescopic Handle 3.6-7.2 mtrs long Nos 1.00 0
16.3.2.14 Floating suction ,made of polyethyene blue color Ø40 mm(1-1/2") 10 mtrs long Nos 1.00 0
16.3.2.15 Leaf net (deep)-clip type Nos 1.00 0
16.3.2.16 Leaf net (flat) clip type Nos 1.00 0
16.3.2.17 Curved brush clip type Nos 1.00 0
16.3.2.18 Test kit for pH and chlorine Nos 1.00 0
16.3.2.19 Algae Brush SS Bristles Nos 1.00 0
16.3.2.20 Straight Brush clip type Nos 1.00 0
16.3.2.21 Ball Valve Solvent type Ø 50 mm Nos 10.00 0
16.3.2.22 Ball Valve Solvent type Ø 63 mm Nos 8.00 0
16.3.2.25 Butterfly Valve Solvent type Ø 110 mm Nos 8.00 0
16.3.2.27 Non-Return Valve Spring type Ø 63 mm Nos 5.00 0
16.3.2.30 Non-Return Valve Wafer type Ø 110 mm Nos 4.00 0
16.3.2.31 Non-Return Valve Wafer type Ø 160 mm Nos 2.00 0
Make : PIMTAS/Hidroten/Coroplas
PVC Piping with complete fittings of 10 bar ISI mark Grey color pipe
16.3.2.32 Ø 50 mm (Main Drain) x 2 separate pipes Rmt 156.00 0
16.3.2.33 Ø 50 mm (Filter to Main Pool Return inlet) Rmt 74.00 0
16.3.2.35 Ø 63 mm (Pump Suction) for Filtration Rmt 6.00 0
16.3.2.36 Ø 50 mm (Pump Delivery) for Filtration Rmt 6.00 0
16.3.2.37 Ø 160 mm x 2nos (Pump Suction) for Cascading Fall Rmt 12.00 0
16.3.2.38 Ø 110 mm x 6nos (Pump Delivery) for Cascading Fall Rmt 66.00 0
16.3.2.39 Ø 63 mm x 1nos Balancing Tank to Pump Suction Header) for Filtration Rmt 6.00 0
16.3.2.40 Ø 160 mm x 1nos Balancing Tank to Pump Suction Header) for Cascading Fall Rmt 6.00 0
16.3.2.41 Ø 63mm Suction Header (Filtration) Rmt 3.00 0
16.3.2.42 Ø 63mm Delivery Header (Filtration) Rmt 3.00 0
16.3.2.43 Ø 160 mm Suction Header (Cascade) Rmt 6.00 0
Make : Prince/Supreme/Finolex
16.3.2.45 Pipe support for ceiling Rmt 20.00 0
Electrical Cable & Conduits with screws and clamp
16.3.2.46 2 core 2.5 mm2 flex-PVC FRLS copper cable Rmt 50.00 0
16.3.2.47 3 core 2.5 mm2 flex-PVC FRLS copper cable Rmt 40.00 0
16.3.2.48 3 core 4 mm2 flexible PVC FRLS copper cable Rmt 60.00 0
16.3.2.49 4 core 4 mm2 flexible PVC FRLS copper cable Rmt 50.00 0
16.3.2.50 Conduits for Cable Rmt 200.00 0
Make : Cable & Conduits -KEI/Polycab
Perforated Pre-galvansided Cable tray 1.6 mm thick for Pumps
Electrical Panel
16.3.2.52 Complete Electrical Panel with CRCA sheet with 14 Gauge with VAF meter, IP42 . Phase indicator lamps , MCB for ( 02 nos.) with indicator lamp with on/off button with selector switch for manual/Auto mode, MCB for recirculation pumps ( 02+03=05 nos.),PHO system (02 nos) RCCB( 30 mA), Heater for Panel ,Exhaust fan for fresh air in the Panel with Potential contact free and Timer for Pumps Nos 1.00 0
uPVC Puddle Flange/Sleeves
16.3.2.60 Labour, Supervision, Erection & Commissioning Lumpsum 1.00 0
16.3.3 Water Body - III
16.3.3.1 TOTALLY NON-CORROSIVE Bobinwound Filter made of Fibreglass with filteration bed depth of 0.5m. Fitted with collector arms and diffusers made from unplasticised PVC and PP. Filter Diameter 1200 mm. MPV Connection: 2.0" Working pressure 2.5kg/cm2, (37.5 PSI), Test pressure 3.75 kg/cm2 (56.25 PSI). Flow rate of 28m³/hour at a specific velocity of 26m³/hr/m². Filter to be supplied complete with lid in polyester resin and fibre glass manual air purge cap, port for sand discharge. Nos 1.00 0
16.3.3.2 Multiport valve 6 way with 2.5" connection to Filter for 5 separate operations. Nos 1.00 0
16.3.3.3 Activated Filter Media © Primarily gives best filtration results, Reduces Backwash, Saves filtered water and has non-biofilming property with life time shelf life for the media. Size: Grade1(80%) Grade2(20%) Lumpsum 1.00 0
Make : Dryden Aqua, Switzerland
16.3.3.4 IE3 Motor: Energy Efficient Self Priming Pump Made from high-temperature engineered thermo-plastic to withstand extreme heat and prevent corrosion. High-grade stainless steel motor shaft. Flow rate 28 m3/hr @10 mtrs head with inbuilt prefilter strainer Capacity 3.0 hp (1.8kw), 2850 rpm, 400 volts (1W+1S) Nos 2.00 0
16.3.3.5 Cascade Fall Pump: Energy Efficient Self Priming Pump Made from high-temperature engineered thermo-plastic to withstand extreme heat and prevent corrosion. High-grade stainless steel motor shaft. Flow rate 28 m3/hr @ 10 mtrs head with inbuilt prefilter strainer Capacity 3.0 hp, 2850 rpm, 400 volts (1W+0S) Nos 1.00 0
16.3.3.6 Combined Photocatalytic and Hydroxyl Radical technology disinfection system for sanitisation of recirculating pond water; the most powerful, proven oxidiser. Hygienic, sterile pool water that sparkles to be installed after the sand filter with Dosage of 60mj/cm2 @ flow rate of 14m3/hr, Lamp: Low Pressure / High Output Double Tube : 2x55W, Lamp Life:14,000 hrs. Nos 2.00 0
Make : ELECRO/Quantum
16.3.3.7 Floating Dispenser for Chlorine Nos 1.00 0
16.3.3.8 Floor inlet in Black ABS plastic with max flowrate 0-12m3/hr with 50 mm glue connection Nos 20.00 0
16.3.3.9 Vacuum point in Black ABS plastic for suction sweeper with 2" connection Nos 3.00 0
16.3.3.10 Rigid PVC wall conduit with Flange for Vacuum point non-threaded 2" Nos 3.00 0
16.3.3.11 Round/Square Drain grill 300mm x 300mm in Black Nos 4.00 0
16.3.3.12 Anodised Extruded Aluminum fixed with clip type connection 1-1/2" Nos 1.00 0
16.3.3.13 Reinforced telescopic Handle 3.6-7.2 mtrs long Nos 1.00 0
16.3.3.14 Floating suction ,made of polyethyene blue color Ø40 mm(1-1/2") 10 mtrs long Nos 1.00 0
16.3.3.15 Leaf net (deep)-clip type Nos 1.00 0
16.3.3.16 Leaf net (flat) clip type Nos 1.00 0
16.3.3.17 Curved brush clip type Nos 1.00 0
16.3.3.18 Test kit for pH and chlorine Nos 1.00 0
16.3.3.19 Algae Brush SS Bristles Nos 1.00 0
16.3.3.20 Straight Brush clip type Nos 1.00 0
16.3.3.21 Ball Valve Solvent type Ø 50 mm Nos 4.00 0
16.3.3.22 Ball Valve Solvent type Ø 63 mm Nos 12.00 0
16.3.3.23 Butterfly Valve Solvent type Ø 75 mm Nos 6.00 0
16.3.3.24 Butterfly Valve Solvent type Ø 90 mm Nos 8.00 0
16.3.3.25 Butterfly Valve Solvent type Ø 110 mm Nos 2.00 0
16.3.3.27 Non-Return Valve Spring type Ø 63 mm Nos 6.00 0
16.3.3.28 Non-Return Valve Wafer type Ø 75 mm Nos 4.00 0
16.3.3.29 Non-Return Valve Wafer type Ø 90 mm Nos 4.00 0
16.3.3.30 Non-Return Valve Wafer type Ø 110 mm Nos 2.00 0
Make : PIMTAS/Hidroten/Coroplas
PVC Piping with complete fittings of 10 bar ISI mark Grey color pipe
16.3.3.32 Ø 63 mm (Main Drain) x 4 separate pipes Rmt 276.00 0
16.3.3.33 Ø 75 mm (Filter to Main Pool Return inlet) Rmt 126.00 0
16.3.3.35 Ø 90 mm (Pump Suction) for Filtration Rmt 90.00 0
16.3.3.36 Ø 75 mm (Pump Delivery) for Filtration Rmt 6.00 0
16.3.3.37 Ø 90 mm (Pump Suction) for Cascading Fall Rmt 72.00 0
16.3.3.38 Ø 75 mm (Pump Delivery) for Cascading Fall Rmt 126.00 0
16.3.3.39 Ø 90 mm Skimmer to Pump Suction Header) for Filtration Rmt 18.00 0
16.3.3.40 Ø 110 mm Balancing Tank to Pump Suction Header) for Cascading Fall Rmt 66.00 0
16.3.3.41 Ø 90 mm Suction Header (Filtration) Rmt 6.00 0
16.3.3.42 Ø 75 mm Delivery Header (Filtration) Rmt 6.00 0
16.3.3.43 Ø 110 mm Suction Header (Cascade) Rmt 6.00 0
16.3.3.44 Ø 90 mm Delivery Header (Cascade) Rmt 6.00 0
Make : Prince/Supreme/Finolex
16.3.3.46 Pipe support for ceiling Rmt 20.00 0
Electrical Cable & Conduits
16.3.3.47 2 core 2.5 mm2 flex-PVC FRLS copper cable Rmt 50.00 0
16.3.3.48 3 core 2.5 mm2 flex-PVC FRLS copper cable Rmt 40.00 0
16.3.3.49 3 core 4 mm2 flexible PVC FRLS copper cable Rmt 60.00 0
16.3.3.50 4 core 4 mm2 flexible PVC FRLS copper cable Rmt 50.00 0
16.3.3.51 Conduits for Cable Rmt 200.00 0
Make : Cable & Conduits -Polycab/Havells
Perforated Pre-galvansided Cable tray 1.6 mm thick for Pumps
Make : Cable & Conduits -Polycab/Havells
Electrical Panel
16.3.3.53 Complete Electrical Panel with CRCA sheet with 14 Gauge with VAF meter, IP42 . Phase indicator lamps , MCB for ( 02 nos.) with indicator lamp with on/off button with selector switch for manual/Auto mode, MCB for recirculation pumps ( 02+06=08 nos.), UV system (01 nos) RCCB( 30 mA), Heater for Panel ,Exhaust fan for fresh air in the Panel with Potential contact free and Timer for Pumps Nos 1.00 0
uPVC Puddle Flange/Sleeves
16.3.3.61 Labour, Supervision, Erection & Commissioning Lumpsum 1.00 0
TOTAL OF WATERBODIES WORKS 0
17. ELEVATORS & ESCALATORS
Note - Refer to Architectural Drawing Set A08 for details
Passenger Elevator
17.1 Design, Fabrication, Supply, Installation, Testing & Commissioning of Electric Traction Type fully automatic Machine room less (MRL) Passenger Elevator having SS Enclosure (Grade 304) with AC variable voltage & variable frequency drive unit suitable for operation on 415 +/- 10 % V, 3 Phase, 50 Hz. AC supply, having speed of 1.50 metres per second, power operated SS center opening type car & landing doors, electro-magnetic brake system, operating panel with luminous buttons, overload warning indicator, battery operated alarm bell, emergency light, intercom suitable for hook up to Facility's EPABX, infrared red sensing door protection for full height (min 2100mm height) & mechanical safety by pressure sensor, reverse phase relay on controller, fire man's switch at ground floor, digital car positions indicator in car with up / down direction indications, light fixtures, ventilation fan, landing sill, main beam in shaft for
machine, pit ladder, provision of lighting in elevator shaft etc. complete with all accessories serving different floors in the lift shaft alongwith Automatic Rescue Device (ARD) including all steel civil and electrical work required for installation of elevator in the exisiting lift well, scaffolding, cutting holes, grouting and making good to damages in wall , floor, ceiling etc. for fixing accessories foundation bolts etc., hoistway wiring and other associated wirings complete in all respects including conveyance, loading, unloading, royalties, taxes, all material and cost all labours sundries, T&P required as per the direction of the Engineer-in-charge and as per following specifications:
17.1.1 Capacity - 24 Passenger Elevator, Stops - 2, Travel Distance - 6.0 m Elevator Car Ht - 2600 mm, Door - 1200 x 2400 mm (A1 - FOH - North Block) Nos 1.00 0
17.1.2 Capacity - 28 Passenger Elevator, Stops - 3, Travel Distance - 14.4 m Elevator Car Ht - 2600 mm, Door - 1200 x 2400 mm (G1 - FOH - South Block) Nos 1.00 0
17.1.3 Capacity - 24 Passenger Elevator, Stops - 3, Travel Distance - 14.4 m Elevator Car Ht - 2600 mm, Door - 1200 x 2400 mm (G2 - FOH - South Block) Nos 1.00 0
17.1.4 Capacity - 15 Passenger Elevator, Stops - 2, Travel Distance - 5.9 m Elevator Car Ht - 2600 mm, Door - 1200 x 2400 mm (G3 - FOH - South Block) Nos 1.00 0
17.1.5 Capacity - 28 Passenger Elevator, Stops - 4, Travel Distance - 20.7 m Elevator Car Ht - 2600 mm, Door - 1200 x 2400 mm (J1 & J2 - FOH - Ellipse Block) Nos 2.00 0
17.1.6 Capacity - 28 Passenger Elevator, Stops - 6, Travel Distance - 30.9 m Elevator Car Ht - 2600 mm, Door - 1200 x 2400 mm (J3 - FOH - Ellipse Block) Nos 1.00 0
17.1.7 Capacity - 22 Passenger Elevator, Stops - 5, Travel Distance - 21.6 m Elevator Car Ht - 2300 mm, Door - 1100 x 2100 mm (B1 & B2 - BOH - North Block) Nos 2.00 0
17.1.8 Capacity - 20 Passenger Elevator, Stops - 3, Travel Distance - 14.4 m Elevator Car Ht - 2300 mm, Door - 1100 x 2100 mm (G4 - BOH - South Block) Nos 1.00 0
17.1.9 Capacity - 20 Passenger Elevator, Stops - 6, Travel Distance - 36.0 m Elevator Car Ht - 2300 mm, Door - 1100 x 2100 mm (J4 - BOH - Ellipse Block) Nos 1.00 0
Goods (Auto) Elevator
17.2 Design, Fabrication, Supply, Installation, Testing & Commissioning of Electric Traction Type fully automatic Machine room less (MRL) Goods (Auto) Elevator having SS Enclosure (Grade 304) with AC variable voltage & variable frequency drive unit suitable for operation on 415 +/- 10 % V, 3 Phase, 50 Hz. AC supply, having speed of 0.50 metres per second, power operated 6 panel center opening type car & landing doors, digital car positions indicator in car with up / down direction indications, light fixtures, ventilation fan, landing sill, main beam in shaft for machine, pit ladder, provision of lighting in elevator shaft etc. complete with all accessories serving different floors in the lift shaft alongwith Automatic Rescue Device (ARD) including all steel civil and electrical work required for installation of elevator in the exisiting lift well, scaffolding, cutting holes, grouting and making good to damages in wall , floor, ceiling etc. for fixing accessories foundation bolts etc., hoistway wiring and other associated wirings complete in all respects including conveyance, loading, unloading, royalties, taxes, all material and cost all labours sundries, T&P required as per the direction of the Engineer-in-charge and as per following specifications:
17.2.1 Freight Elevator Capacity - 3000 kg, Cabin Size internal - 2800x5750x3000, Stops - 4, Travel Distance -14.4 m, Both Side Opening (C1 - North Block) Nos 1.00 0
17.2.2 Freight Elevator Capacity - 3000 kg, Cabin Size internal - 2800x5750x3000, Stops - 3, Travel Distance -14.4 m, Both Side Opening (G5 - South Block) Nos 1.00 0
17.2.3 Freight Elevator Capacity - 3000 kg, Cabin Size internal - 2800x5750x3000, Stops - 5, Travel Distance -25.8 m, Both Side Opening (J5 - Ellipse Block) Nos 2.00 0
17.3 Design, Fabrication, Supply, Installation, Testing & Commissioning of Escalators adhering to IS: 17900, including all steel civil and electrical work required for installation complete in all respects including conveyance, loading, unloading, royalties, taxes, all material and cost all labours sundries, T&P required as per the direction of the Engineer-in-charge and as per following specifications:
17.3.1 Type : Indoor Vertical Rise : 6000 mm Length : 13,372 mm Width : 800 mm Speed : 0.5 m/s Inclination : 35 deg Horizontal Step Run : 2 (top) + 2 (bottom) (ES-A1 & A2 - North Block) Nos 2.00 0
17.3.2 Type : Indoor Vertical Rise : 7200 mm Length : 17,980 mm Width : 1000 mm Speed : 0.5 m/s Inclination : 30 deg Horizontal Step Run : 3 (top) + 3 (bottom) (ES-G1 & G2 - South Block) Nos 2.00 0
17.3.3 Type : Indoor Vertical Rise : 6900 mm Length : 17,460 mm Width : 1000 mm Speed : 0.5 m/s Inclination : 30 deg Horizontal Step Run : 3 (top) + 3 (bottom) (ES-J1, J2 & J2 - Ellipse Block) Nos 3.00 0
17.3.4 Type : Indoor Vertical Rise : 5100 mm Length : 12,887 mm Width : 1000 mm Speed : 0.5 m/s Inclination : 35 deg Horizontal Step Run : 2 (top) + 2 (bottom) (ES-J4 & J5 - Ellipse Block) Nos 2.00 0
17.4 Design, Fabrication, Supply, Installation, Testing & Commissioning of Hydraulic Scissor Lifter (Dock Leveller) including all steel civil and electrical work required for installation complete in all respects including conveyance, loading, unloading, royalties, taxes, all material and cost all labours sundries, T&P required as per the direction of the Engineer-in-charge and as per following specifications:
17.4.1 Electro Hydraulic RDL Series Dock Leveler Capacity - 3 Ton. Platform Size – L 2500 mm X W 3000 mm Side Railing - 2 sides 900 mm Lift Height - 1200mm / Closed Height - 550mm LIP - Hydraulic Nos 1.00 0
TOTAL OF ELEVATORS & ESCALATORS 0
18. DEMOLITION & DISMANTLING WORK
18.1 Demolition including stacking of serviceable materilas and disposal of unserviceable materials with all lead and lift. (i) R.C.C. work Cum 50.00 0
18.2 Demolition of Brick work and stone masonry including stacking of serviceable materilas and disposal of unserviceable materials with all lead and lift.(ii) In Cement Mortar. Cum 50.00 0
18.3 Dismentaling tiled of stone floors laid in mortar including stacking of serviceable materilas and disposal of unserviceable materials with all lead and lift. Sqm 100.00 0
TOTAL OF DEMOLITION & DISMANTLING WORK 0
19. BARRICADDING WORK
19.1 Providing & Erecting 3.0 m high Barricades as per following specifications including gates for access points to the site Item includes pits of 600 mm X 600 mm X 600 mm size in Soil by (Hydraulic mechanical excavator)/manual means over areas including getting out and disposal of excavated earth off the site, Concreting in pits with M20 grade / 1:1.5:3 concrete, embedding Structural Steel vertical member with MS Plate of 250 X 250 X 5 mm thk at the base of Vertical Member of Barricades Providing Horizontal Steel Tube 50 X 50 X 4 mm Structural members for Barricades, 50 X 50 X 4 mm Thk Tube for framing of gate, 40 X 40 X 5 mm Angle bracing, ISMC 150 mm Side posts for Gates, 100 mm ISMC Vertical members for Barricades as per given drawings. Item also includes red oxide / zinc chromate primer one coat and 2 coats of Oil Painting of approved brand and manufacturer on steel works. Item also includes all necessary hardware, hinges, locking arrangement for Gates etc. Complete. Item include providing and fixing 0.8 mm thk. pre-coated galvalume corrugated/plane sheet of approved make. Only Exposed Pre-coated Sheet Area shall be measured for the Payment. Sqm 3,250.80 0
The barricading provided shall be retained in position at site continuously (including any shifting if required) and shall not be removed without prior approval of Engineerin- Charge. Only Exposed Pre-coated Sheet Area shall be measured for the Payment. The barricading provided shall remain to be the property of the contractor on completion of the work).
TOTAL OF BARRICADDING WORK 0
20. MISCELLANEOUS WORK
20.1 Providing and embedding G.I. pipe sleeve (Medium Grade), in RCC Wall/ Slab etc., including welding lugs to the pipes, erecting in position in proper line, level, temporary blocking of the sleeves with sand filling and sealing in the ends with cement mortar 1:6 (1cement:6 coarse sand) etc., complete as shown in the drawing and as per the instructions of the ENGINEER.
20.1.1 -do- but for 100mm dia Rmt 100.00 0
20.1.2 -do- but for 150mm dia Rmt 100.00 0
20.1.3 -do- but for 200mm dia Rmt 100.00 0
20.6 Providing & fixing in position 10mm thick thermocol board of approved make in between RCC floor and brick masonry joints as per instruction of engineer in charge.etc. complete. (Note: Themocol sheet to be place in position before laying the concrete.) (laps will not be counted in measurements). Sqm 100.00 0
20.8 Providing and fixing anchor fasteners of approved make including chemical drilling hole in RCC, finishing the surface etc complete as per the instructions of Engineer-in-Charge.
20.8.1 20mm dia x 100mm long Nos 100.00 0
20.8.2 20mm dia x 150mm long Nos 100.00 0
20.9 Providing and fixing expandable anchor bolts (Hilti or Fischer) in concrete or masonry including drilling, cleaning the holes, ramming the bolts in the holes in accordance with IS and manufacturer’s specifications for fixing plates or other steel members to already cast concrete surfaces etc. complete as per satisfaction of the PM.
20.10 CORE CUTTING Drilling or Core cutting horizontal, vertical or inclined holes in reinforced cement concrete and / or hard rock of following sizes for a depth / length at all levels and locations as per directions of the PM.
Providing & fixing of Rebars in position with mild steel HYSD bar reinforcement of required dia for RCC member with Friulsider India Limited KEM EP- 934 grade bars/Hilti Make including drilling upto 150mm depth as per RCC consultant, cleaning, injecting hilti or equivalent epoxy & fixing etc complete.
TOTAL OF MISCELLANEOUS WORK 0
21 KITCHEN EQUIPMENT
21.1 KITCHEN IN ELLIPTICAL BLOCK
GEK - 1 DISH WASH & POT Wash
GEK - 1.1 Solid Dish Receving Table With Glass Rack 1650 x 600 x 850 + 600 + 150 Nos 1.00 0
GEK - 1.2 Grease Chamber 508 x 410 x 250 Nos 1.00 0
GEK - 1.3 Garbage Bin - 80 L Nilkamal WB80L or equivalent Nos 1.00 0
GEK - 1.5 Pre Rinse Sink Unit with T & S Ball Valve 700 x 700 x 850 + 100 Nos 1.00 0
GEK - 1.6 Pre Rinse Shower (Deck Mounted) T & S BRASS & BRONZE WORKS EX-1DP00H or equivalent Nos 1.00 0
GEK - 1.7 Hood Type Dish Washer 505089 (NHT8P) or equivalent Nos 1.00 0
GEK - 1.8 Clean Dish Table 600 x 700 x 850 + 100 Nos 1.00 0
GEK - 1.9 Water Softener Pentair PWCE35P12 or equivalent Nos 1.00 0
GEK - 1.10 Insect Killer Technocrat Trapper or equivalent Nos 1.00 0
GEK - 1.11 Pre Rinse Shower (Wall Mounted) T & S BRASS & BRONZE WORKS B-0133-ADF12-B or equivalent Nos 1.00 0
GEK - 1.12 Clean Dish Rack (5 Shelves) 900 x 450 x 1650 Nos 1.00 0
GEK - 1.13 Clean Dish Rack (5 Shelves) 900 x 600 x 1650 Nos 1.00 0
GEK - 1 KITCHEN
GEK - 2.1 Work Table with 1 U/SH 450 x 750 x 850 + 100 Nos 1.00 0
GEK - 2.2 Deep Fat Fryer (Twin Chember ) 625 x 750 x 850 + 100 Nos 1.00 0
GEK - 2.3 Griddle Grill Plate 900 x 750 x 850 + 100 Nos 1.00 0
GEK - 2.4 Work Table with 1 U/SH 450 x 750 x 850 + 100 Nos 1.00 0
GEK - 2.5 4 Burner Range With Electrict Oven 750 x 750 x 850 + 100 Nos 1.00 0
GEK - 2.6 Sink Unit 600 x 750 x 850 + 100 Nos 1.00 0
GEK - 2.7 2 Burner Range 1200 x 750 x 850 + 100 Nos 1.00 0
GEK - 2.8 Work Table with 2 U/SH 600 x 750 x 850 + 100 Nos 1.00 0
GEK - 2.9 Storage Rack (5- Shelves) 750 x 750 x 1650 Nos 1.00 0
GEK - 2.10 GN Size 2 Door Table Top Refrigerator With Raised Bain Marie 1500 x 750 x 850 + 150 TRUFROST SH 2000/80 or equivalent Nos 1.00 0
GEK - 2.11 Wall Shelf - 1000 x 500 Nos 1.00 0
GEK - 2.12 Pizza Oven - 480 x 465 x 240 Rollergrill PZ 330 or equivalent Nos 2.00 0
GEK - 2.13 Work Table with 2 U/SH 1250 x 750 x 850 + 150 Nos 1.00 0
GEK - 2.14 Sandwich Griller Simran ELIO-RR or equivalent Nos 2.00 0
GEK - 2.15 Wall Shelf - 1250 x 300 Nos 1.00 0
GEK - 2.16 GN Size 2 Door Table Top Refrigerator 1500 x 750 x 850 + 150 TRUFROST GN 2100TN or equivalent Nos 1.00 0
GEK - 2.17 Wall Shelf -1500 x 300 Nos 1.00 0
GEK - 2.18 Ice Cream Cabinet 750 x 600 x 850 TRUFROST CF 225 PREMIA or equivalent Nos 1.00 0
GEK - 2.19 Pickup Counter With 2 U/SH & 2 OH/SH, Cabinet, R.R & KOT Printer Strip 1500 x 750 x 850 + 450 + 375 + 200 Nos 1.00 0
GEK - 2.20 Storage Rack (5- Shelves) - 900 x 450 x 1650 Nos 1.00 0
GEK - 2.21 Water Cooler - 80 L BLUE STAR SWC6080SS or equivalent Nos 1.00 0
GEK - 3 CAFE COUNTER
GEK - 3.1 GN Size 2 Door Table Top Refrigerator 1500 x 600 x 850 + 100 TRUFROST GN 2100TN or equivalent Nos 1.00 0
GEK - 3.2 Microwave oven (Capacity 21 Liters) LG MC2186bg or equivalent Nos 1.00 0
GEK - 3.3 Work Table with Sink ON L.H.S & Bottam Storage 1050 x 600 x 850 + 100 Nos 1.00 0
GEK - 3.4 Work Table with Bottam Storage 1200 x 600 x 850 + 100 Nos 1.00 0
GEK - 3.5 Coffee Grinder LA CARIMALI X010 or equivalent Nos 1.00 0
GEK - 3.6 Coffee Machine ( 10 liters/hour RO water required) LA CARIMALI pratica e2 or equivalent Nos 1.00 0
GEK - 3.7 Cold Display Counter - 1200 x 750 x 1200 Nos 1.00 0
GEK - 3.8 Ambient Display Counter - 1200 x 750 x 1200 Nos 1.00 0
GEK - 3.9 PVC Strip Curtains - 900 x 2500 Nos 1.00 0
GEK - 4.1 Cam Shelving ( WITH FOLLOWING COMPONENTS) - CAMBRO or equivalent
A Post - 610 x 1830 Nos 3.00 0
B Shelves - 1530 x 610 x 1830 Nos 5.00 0
C Shelves - 1070 x 610 x 1830 Nos 5.00 0
GEK - 4.2 PVC Strip Curtains - 1900 x 2500 Nos 1.00 0
GEK - 4.3 Air-Curtain - 900mm Length DOLPHY DACN007 or equivalent Nos 1.00 0
GEK - 5.1 Step In Refrigerator with Racks 1800 x 1200 x 2500 - TRUFROST or equivalent Nos 1.00 0
GEK - 5.3 Work Table - 1750 x 750 x 850 + 100 Nos 1.00 0
GEK - 5.4 Dough Sheeter (Table Top) 1460 x 940 x 580 - SINMAG SM520S or equivalent Nos 1.00 0
GEK - 5.5 Ingredient Bins CAMBRO IBS27 or equivalent Nos 2.00 0
GEK - 5.6 Spiral Dough Kneader (25 kg Flour Capacity ) 600 x 930 x 1190 - SINMAG SM - 50T or equivalent Nos 1.00 0
GEK - 5.7 Work Table with 2 U/SH - 1200 x 450 x 850 + 100 Nos 1.00 0
GEK - 5.8 Planetary Mixer ( 5 Ltrs) Table Top SINMAG SM-51 or equivalent Nos 1.00 0
GEK - 5.9 Work Table with 2 U/SH - 900 x 450 x 850 + 100 Nos 1.00 0
GEK - 5.10 Tray Rack Trolley - 450 x 600 x 1800 Nos 1.00 0
GK - 5.11 Convection Oven with underneath Proofer 780 x 1253 x 590 (Proofer 780 x 1000 x 1057) SINMAG SM-705EE + SM-716F or equivalent Nos 1.00 0
GEK - 5.12 Granite Top Table with 2U/SH 1200 x 750 x 850 + 100 Nos 1.00 0
GEK - 5.13 Wall Shelf - 1200 x 350 Nos 1.00 0
GEK - 5.14 GN Size 2 Door Vertical Deep Freezer - 725 x 825 x 2050 TRUFROST GN 680 BTM or equivalent Nos 1.00 0
GEK - 5.15 Storage Cupbord - 600 x 825 x 1800 Nos 1.00 0
GEK - 5.16 Storage Rack (5- Shelves) - 900 x 450 x 1650 Nos 1.00 0
GEK - 5.17 Hand Wash Sink with Soap Dispenser - 500 x 475 x 300 + 300 Nos 1.00 0
GEK - 5.18 Insect Killer Technocrat Trapper or equivalent Nos 1.00 0
GEK - 6 EXHAUST HOOD
GEK - 6.1 S.S. Exhaust Single Skin Hood with Filters 4700 x 900 x 500 Nos 1.00 0
GEK - 6.2 S.S. Exhaust Single Skin Hood with Filters 1100 x 650 x 500 Nos 1.00 0
GEK - 6.3 S.S. Exhaust Single Skin Hood with Filters 900 x 1400 x 500 Nos 1.00 0
GEK - 6.4 Exhaust Grill for Hood Type Dish Wash (GV-1.7) 300 x 200 Nos 1.00 0
GEK - 6.5 Fire Suppression System SWASTIC SYNERGY, CEASEFIR or equivalent
A Stainless Steel Wet Chemical Cylinder with Valve duly filled & Pressurized - Cap 24 L Nos 1.00 0
A.1 Stainless Steel Wet Chemical Cylinder with Valve duly filled & Pressurized - Cap 6 L Nos 2.00 0
B Manual Activation Pull Station Nos 3.00 0
C Automatic Mechanical Activation Panel Nos 3.00 0
D Multiple - Nozzle for Ranges Nos 12.00 0
E Multiple - Nozzle for Plenum and Duct Nos 10.00 0
F Fusible Links with Brackets Nos 12.00 0
G Corner Pulley Nos 24.00 0
H INSTALLATION Nos 3.00 0
GEK - 7 GRATING & CORNER GUARD
GEK - 7.1 S.S Grating - 600 x 300 Nos 5.00 0
GEK - 7.2 S/S Corner Guard - 2400 Ht. Nos 9.00 0
GEK - 8 GAS SYSTEM
A ELLIPTICAL GAS BANK
15 GAS MANIFOLDS AND PRS SYSTEM INCLUDING: MS MANIFOLD SET With SAFETY SHUT-OFF VALVE (2x6=12 Nos Cylinders), 1ST STAGE HIGH PRESSURE REGULATOR (VANAZ/GASO MAKE), CYLINDER ADAPTORS. (CLICK-ON: GASO MAKE) - 12Pcs, CYLINDER PIGTAIL FLEX (POLYFLEX / UNITED MAKE)- 12Pcs, NON RETURN VALVE (GASO MAKE)- 12Pcs. PRESSURE GAUGE with ISOLATION VALVE (United Make) - 2 Set Nos 1.00 0
16 MS HEAVY GRADE C CLASS (TATA/JINDAL) GAS PIPE (1.5" DIA) INCLUDING ALL MS SCH-40 SEAMLESS GRADE - ELBOWS, TEE'S, BARREL NIPPLES, ADAPTORS, NUTBOLTS, GASKETS. (APPROXIMATE LENGTH) Nos 200.00 0
17 1.5" DIA MAINLINE BALL VALVE (V&G /AUDCO "L&T" FIRE SAFE SERIES) Nos 2.00 0
18 1" DIA EQUIPMENT ISOLATION BALL VALVE (ITAP-ITALY ) AND HOSE PIPE FOR EACH EQUIPMENT 1.5 m LONG Nos 3.00 0
19 AUTOMATED SOLENOID GAS SHUTOFF VALVE WITH LOCKING MECHANISM AND MANUAL RESET FOR SAFETY. SIZE:1.5" MAKE: MADAS - ITALY Nos 1.00 0
20 SUPPORTING CLAMPS 'M' TYPE/HANGING RODS/ "ANGULAR TYPE" Nos 1.00 0
21 MS FLANGE (1.5" DIA) GRADE "ASA" Nos 6.00 0
22 CHARGES FOR DRAWING OF 3D-ISOMETRIC LAYOUT OF ENTIRE GASLINE SYSTEM AS PER ACTUAL SIZES AND MEASUREMENT - ROUTINGS - GAS CONNECTIONS. Nos 1.00 0
23 PAINTING OF ENTIRE GAS PIPELINE ONLY WITH YELLOW OIL PAINT Nos 1.00 0
24 HIGH PRESSURE COMPRESSED AIR TESTING AS PER MAHANAGAR GAS (MGL) REQUIREMENTS & ISSUING OF TEST CERTIFCATE Nos 1.00 0
25 CHARGES FOR LABOUR AND INSTALLATION OF MS GAS PIPING AND ALL FITTINGS FOR PNG DISTRIBUTION SYSTEM Nos 200.00 0
26 Fitting Charges for Automated Solenoid Gas Shutoff Valve for Fire Suppression System Size:1.5", in our PNG Gas Pipeline INCLUDING COST OF BARREL NIPPLES, FLANGES, GASKETS, STUD NUTBOLTS, WELDING, TESTING, FIXING AND PAINTING. Nos 1.00 0
B ELLIPTICAL KITCHEN GLD
1 GAS LEAK DETECTION SYSTEM INSTALLATION INCLUDING, (A) GAS LEAK DETECTORS : 02 NOS (RANGE : 0-100% LEL FOR LPG, TYPE: CATALYTIC, DISPLAY : 7 SEGMENT LED COMPLETE WITH JUNCTION BOX & CABLE GLAND FLAME PROOF CERTIFIED FOR IIA & IIB [PESO CERTIFICATE / APPROVED]. (B) SMART ALARM PANEL CUM POWER SUPPLY WITH ZONE SEGREGATION AND INTEGRATED GSM MODULE WITH SIM CARD COMPATIBILITY. CAN BE CONFIGURED TO SEND SMS IN CASE OF LEAK DETECTION & ELECTRIC HOOTER. (C) CONNECTION OF ABOVE MENTION MATERIAL ON SITE (LDS) (D) CHARGES FOR ISSUING OF "FORM - A" FOR GAS LEAK DETECTION SYSTEM ONLY. Nos 1.00 0
EEK - 1.1 Cold Display Counter - 900 x 600 x 1200 Nos 1.00 0
EEK - 1.2 Ambient Display Counter - 900 x 600 x 1200 Nos 1.00 0
EEK - 1.3 Work Table with 2 U/SH - 1100 x 400 x 850 Nos 1.00 0
EEK - 1.4 Work Table With Sink on L.S.H & Bottom Storage 1500 x 700 x 900 + 100 Nos 1.00 0
EEK - 1.5 Wall Shelf - 1500 x 300 Nos 1.00 0
EEK - 1.6 Induction Hub - 350 x 415 x 120 STELLA TS-3501 or equivalent Nos 1.00 0
EEK - 1.7 Sandwich Griller - 260 x 435 x 235 SIRMAN - ELIO-RR or equivalent Nos 1.00 0
EEK - 1.8 Work Table - 650 x 700 x 900 + 100 Nos 1.00 0
EEK - 1.9 Hot Holding Cabinet - 475 x 600 x 800 CORNELL HBC05S or equivalent Nos 1.00 0
EEK - 1.10 Ice Cream Cabinet 850 x 700 x 900 TRUFROST CF 225 PREMIA or equivalent Nos 1.00 0
EEK - 1.11 Wall Shelf - 600 x 500 Nos 1.00 0
EEK - 1.12 Microwave oven (Capacity 21 Liters) LG - MC2186BG or equivalent Nos 1.00 0
EEK - 1.13 Visi Cooler - 600 x 650 x 1850 ELANPRO - ECG406 or equivalent Nos 1.00 0
EEK - 1.14 Bain Marie (GN 1/2 x 2) - 400 x 650 x 300 Nos 1.00 0
21.2 GROUND FLOOR KITCHEN
GGK - 1 RECEVING AREA
GGK - 1.1 Work Table with 2 U/SH - 750 x 600 x 850 + 100 Nos 1.00 0
GGK-1.3 Weighing Scale (Floor Model) - 100 kg Capacity ACZET PRIVATE LIMITED - CTG100 or equivalent Nos 1.00 0
GGK - 1.4 Storage Rack (5- Shelves) - 1200 x 600 x 1650 Nos 1.00 0
GGK - 1.5 Platfrom Trolley - 900 x 600 x 850 Nos 1.00 0
GGK-1.6 Air-Curtain - 1500mm Length DOLPHY DACN0009 or equivalent Nos 1.00 0
GGK- 2 STORE ROOM
GGK- 2.1 Step In Refrigerator with Racks 1800 x 1200 x 2100 Nos 1.00 0
GGK- 2.2 GN Size 2 Door Vertical Deep Freezer 725 x 825 x 2050 TRUFROST GN 680 BTM Nos 1.00 0
GGK- 2.3 Sack Pallet - 1000 x 1200 x 150 NILKAMAL - SP1210 or equivalent Nos 2.00 0
GGK- 2.4 Cam Shelving ( WITH FOLLOWING COMPONENTS) - CAMBRO or equivalent
A Post - 610 x 1830 Nos 5.00 0
B Shelves - 1530 x 610 x 1830 Nos 10.00 0
C Shelves - 1070 x 610 x 1830 Nos 10.00 0
GGK - 2.5 Insect Killer Technocrat Trapper or equivalent Nos 1.00 0
GGK - 3 NON VEG SECTION
GGK - 3.1 GN Size 2 Door Vertical Refrigerator 725 x 825 x 2050 TRUFROST GN 680 TNM or equivalent Nos 1.00 0
GGK - 3.2 Work Table With Sink On L.H.S - 1000 x 600 x 850 + 100 Nos 1.00 0
GGK - 3.3 2 Burner Range - 1200 x 600 x 850 + 100 Nos 1.00 0
GGK - 3.4 Work Table with 2 U/SH - 450 x 600 x 850 + 100 Nos 1.00 0
GGK - 3.5 Storage Rack (5- Shelves) - 1200 x 450 x 1650 Nos 1.00 0
GGK - 3.6 Work Table with 2 U/SH - 1200 x 450 x 850 + 100 Nos 1.00 0
GGK - 4 WET-PREPARATION
GGK - 4.1 Tilting Commercial Wet Grinder 15 Lit. Capacity (665 x 765 x 1100) COSMOS CMG15 Nos 2.00 0
GGK - 4.2 Pulverizer - 70 KG. / 1HR. (400 x 680 x 1400mm) COSMOS IMG 70 Nos 1.00 0
GGK - 4.3 Potato Peeler - 20 KG Capacity (470 x 800 x 1140) COSMOS CP20 or equivalent Nos 1.00 0
GGK - 4.5 Coconut Scraper - Floor Type - 345 x 530 x 940 Nos 1.00 0
GGK - 5 PRE-PREPARATION AREA
GGK - 5.4 Work Table with Sink ON L.H.S & 2 U/SH 1500 x 750 x 850 + 100 Nos 1.00 0
GGK - 5.5 Wall Shelf - 1500 x 300 Nos 1.00 0
GGK - 5.6 Work Table with 2 U/SH 1500 x 750 x 850 + 100 Nos 1.00 0
GGK - 5.7 Wall Shelf - 1500 x 300 Nos 1.00 0
GGK - 5.8 GN Size 2 Door Vertical Refrigerator 725 x 825 x 2050 - TRUFROST GN 680 TNM or equivalent Nos 1.00 0
GGK - 5.9 GN Size 2 Door Vertical Deep Freezer 725 x 825 x 2050 - TRUFROST GN 680 BTM or equivalent Nos 1.00 0
GGK - 5.10 Vegetable Crate Rack Trolley - 450 x 600 x 1800 Nos 2.00 0
GGK - 6 CONTINENTAL & CHINESE
GGK - 6.1 Work Table with 2 U/SH - 550 x 950 x 850 + 100 Nos 1.00 0
GGK - 6.2 3 Burner Chinese range ( 2 VOK 1 STOCK No. burner; With blower) - 1675 x 950 x 750 + 450 Nos 1.00 0
GGK - 6.3 Work Table with 1 U/SH - 600 x 950 x 850 + 100 Nos 1.00 0
GGK - 6.4 Deep Fat Fryer (Twin Chember ) - 625 x 950 x 850 + 100 Nos 1.00 0
GGK - 6.5 4 Burner Range - 900 x 950 x 850 + 100 Nos 1.00 0
GGK - 6.6 Griddle Grill Plate - 600 x 950 x 850 + 100 Nos 1.00 0
GGK - 6.8 Work Table with 2 U/SH - 1200 x 450 x 850 + 100 Nos 1.00 0
GGK - 6.9 Work Table with 2 U/SH - 900 x 450 x 850 Nos 2.00 0
GGK - 6.10 GN Size 2 Door Table Top Refrigerator 1350 x 750 x 850 + 100 TRUFROST GN 2100TN Nos 1.00 0
GGK - 6.11 Wall Shelf - 1350 x 300 Nos 1.00 0
GGK - 6.12 Hand Wash Sink with Soap Dispenser - 500 x 475 x 300 + 300 Nos 1.00 0
GGK - 6.13 Insect Killer Technocrat Trapper or equivalent Nos 1.00 0
GGK - 7 INDIAN RANGE
GGK - 7.1 Work Table with 2 U/SH 450 x 750 x 850 + 100 Nos 1.00 0
GGK - 7.2 Snacks Fryer (Kadai) 750 x 750 x 850 Nos 1.00 0
GGK - 7.3 Granite Top Table with 2 U/SH 1000 x 750 x 850 + 100 Nos 1.00 0
GGK - 7.4 Chapatti Plate with Puffer 1500 x 750 x 850 + 100 Nos 1.00 0
GGK - 7.5 Work Table with 2 U/SH 450 x 450 x 850 Nos 1.00 0
GGK - 7.6 Sink Unit 600 x 750 x 850 + 100 Nos 1.00 0
GGK - 7.7 2 Burner Range 1200 x 750 x 850 + 100 Nos 1.00 0
GGK - 7.8 Work Table with 2 U/SH 450 x 750 x 850 + 100 Nos 1.00 0
GGK - 7.9 Work Table with 2 U/SH 600 x 450 x 850 + 100 Nos 1.00 0
GGK - 7.10 Single Burner Bulk Range 750 x 750 x 600 Nos 1.00 0
GGK - 7.11 Work Table with 2 U/SH 450 x 900 x 850 + 100 Nos 1.00 0
GGK - 7.12 2 Burner Range 1200 x 900 x 850 + 100 Nos 1.00 0
GGK - 8 TANDOOR
GGK - 8.1 Sink Unit 600 x 900 x 850 + 100 Nos 1.00 0
GGK - 8.2 Side Table with 2 U/SH 600 x 900 x 1000 + 100 Nos 1.00 0
GGK - 8.3 S.S Coal Tandoor on Wheel 900 x 900 x 1000 Nos 2.00 0
GGK - 8.4 Skewer Hanging Rod with drip box 600 x 100 Nos 2.00 0
GGK - 8.5 Side Table with 2 U/SH 500 x 900 x 1000 + 100 Nos 1.00 0
GGK - 8.6 GN Size 2 Door Table Top Refrigerator 1350 x 700 x 850 + 100 TRUFROST GN 2100TN or equivalent Nos 1.00 0
GGK - 8.7 Wall Shelf 1350 x 300 Nos 1.00 0
GGK - 8.8 Storage Rack (5- Shelves) 1200 x 700 x 1650 Nos 1.00 0
GGK - 9 PICK UP COUNTER
GGK - 9.1 Hot Bain Marie (1/2 GN x 10) 1800 x 700 x 850 + 100 Nos 1.00 0
GGK - 9.2 Work Table with 2 U/SH 900 x 700 x 850 + 100 Nos 1.00 0
GGK - 9.3 Pickup Counter With 2 U/SH & 2 OH/SH, Cabinet, R.R & KOT Printer Strip 1500 x 750 x 850 + 450 + 375 + 200 Nos 1.00 0
GGK - 9.4 Tray Rest With Bottom Storage 1500 x 350 x 800 Nos 1.00 0
GGK - 9.5 Insect Killer Technocrat Trapper or equivalent Nos 1.00 0
GGK - 10 SNACKS
GGK - 10.1 GN Size 2 Door Table Top Refrigerator With B.M 1350 x 700 x 850 - TRUFROST SH 2000/800 Nos 1.00 0
GGK - 10.2 Work Table with Sink ON R.H.S 2 U/SH & 2 OH/SH With B.M - 1350 x 700 x 850 + 450 + 375 Nos 1.00 0
GGK - 10.4 Work Table with 2 U/SH - 850 x 750 x 850 + 100 Nos 1.00 0
GGK - 10.5 Work Table with 2 U/SH - 850 x 700 x 850 + 100 Nos 1.00 0
GGK - 10.6 Idli Steamer (54 Idli Capacity) - 750 x 650 x 575 Nos 1.00 0
GGK - 10.7 GN Size 2 Door Vertical Deep Freezer 725 x 825 x 2050 - TRUFROST GN 680 BTM or equivalent Nos 1.00 0
GGK - 10.8 Storage Rack (5- Shelves) - 750 x 450 x 1650 Nos 1.00 0
GGK - 11 POT WASH
GGK - 11.1 Pre Rinse Shower (Wall Mounted) T & S BRASS & BRONZE WORKS EX-6WP12-H or equivalent Nos 1.00 0
GGK - 11.2 Pot Rack Shleves ( 4 Shelves ) - 1200 x 600 x 1650 Nos 2.00 0
GGK - 12 DISH WASH
GGK - 12.1 Solid Dish Receving Table With Glass Rack 1800 x 750 x 850 + 600 + 150 Nos 1.00 0
GGK - 12.2 2 Sink Pre Rinse Unit with T & S Ball Valve 1200 x 700 x 850 + 100 Nos 1.00 0
GGK - 12.3 Pre Rinse Shower (Deck Mounted) T & S BRASS & BRONZE WORKS - EX - 1DP00H or equivalent Nos 1.00 0
GGK - 12.4 Hood Type Dish Washer (746 x 755 x 1549) ELECTROLUX 505089 (NHT8P) or equivalent Nos 2.00 0
GGK - 12.6 Clean Dish Table - 1150 x 700 x 850 + 100 Nos 1.00 0
GGK - 12.7 Insect Killer Technocrat Trapper or equivalent Nos 1.00 0
GGK - 12.8 Storage Rack (5 Shelves) - 1200 x 600 x 1650 Nos 2.00 0
GGK - 12.9 Garbage Bin - 80 L Nilkamal WB80L or equivalent Nos 1.00 0
GGK-12.10 Water Softener - 309 X 446 X 1228 PENTAIR PWCE35P12 or equivalent Nos 2.00 0
GGK - 12.11 Grease Chamber - 508 x 410 x 250 Nos 1.00 0
GGK- 13 WATER STATION
GGK- 13.1 Water Cooler - 80 L BLUESTAR SWC6080SS or equivalent Nos 1.00 0
GGK- 13.2 Staorage Rack (5 Shelves) - 900 x 450 x 1650 Nos 1.00 0
GGK- 13.3 Hand Wash Sink with Soap Dispenser 500 x 475 x 300 + 300 Nos 1.00 0
GGK - 14 STAFF LOCKERS
GGK - 14.1 S.S. Bench - 900 x 350 x 600 Nos 2.00 0
GGK- 14.2 Staff Lockers ( 12 LOCKERS ) - 900 x 475 x 1950 Nos 5.00 0
GGK - 15 EXHAUST HOOD
GGK - 15.1 S.S. Exhaust SINGLE Skin Hood with Filters - 1350 x 750 x 500 Nos 1.00 0
GGK - 15.2 S.S. Exhaust SINGLE Skin Hood with Filters - 4550 x 1100 x 500 Nos 1.00 0
GGK - 15.3 S.S. Exhaust SINGLE Skin Hood with Filters - 900 x 900 x 500 Nos 1.00 0
GGK - 15.4 S.S. Exhaust SINGLE Skin Hood with Filters - 3450 x 900 x 500 Nos 1.00 0
GGK - 15.5 S.S. Exhaust SINGLE Skin Hood with Filters - 2600 x 1050 x 500 Nos 1.00 0
GGK - 15.6 S.S. Exhaust SINGLE Skin Hood with Filters - 2450 x 1050 x 500 Nos 1.00 0
GGK - 15.7 S.S. Exhaust SINGLE Skin Hood with Filters - 1250 x 900 x 500 Nos 1.00 0
GGK - 15.8 S.S. Exhaust SINGLE Skin Hood with Filters - 900 x 750 x 500 Nos 1.00 0
GGK - 15.9 Exhaust Grill for Hood Type Dish Wash (GV-12.4) - 300 x 200 Nos 2.00 0
GGK - 15.10 Fire Suppression System SWASTIC SYNERGY, CEASEFIR or equivalent
A Stainless Steel Wet Chemical Cylinder with Valve duly filled & Pressurized - 9 L Nos 2.00 0
A.1 Stainless Steel Wet Chemical Cylinder with Valve duly filled & Pressurized - 24 L Nos 1.00 0
A.2 Stainless Steel Wet Chemical Cylinder with Valve duly filled & Pressurized - 6 L Nos 2.00 0
A.3 Stainless Steel Wet Chemical Cylinder with Valve duly filled & Pressurized - 18 L Nos 1.00 0
A.4 Stainless Steel Wet Chemical Cylinder with Valve duly filled & Pressurized - 12 L Nos 2.00 0
B Manual Activation Pull Station Nos 8.00 0
C Automatic Mechanical Activation Panel Nos 8.00 0
D Multiple - Nozzle for Ranges Nos 33.00 0
E Multiple - Nozzle for Plenum and Duct Nos 25.00 0
F Fusible Links with Brackets Nos 34.00 0
G Corner Pulley Nos 64.00 0
H INSTALLATION Nos 8.00 0
GGK-16 GRATING & CORNER GUARD
GGK-16.1 S.S Grating - 600 x 300 Nos 14.00 0
GGK-16.2 S/S Corner Guard - 2400 Ht. Nos 28.00 0
GGK-17 GAS SYSTEM
1 GAS MANIFOLDS AND PRS SYSTEM INCLUDING: MS MANIFOLD SET With SAFETY SHUT-OFF VALVE (2x12=24 Nos Cylinders), 1ST STAGE HIGH PRESSURE REGULATOR (VANAZ/GASO MAKE), CYLINDER ADAPTORS. (CLICK-ON: GASO MAKE) - 24Pcs, CYLINDER PIGTAIL FLEX (POLYFLEX / UNITED MAKE)- 24Pcs, NON RETURN VALVE (GASO MAKE)- 24Pcs. PRESSURE GAUGE with ISOLATION VALVE (United Make) - 2 Set Nos 1.00 0
2 MS HEAVY GRADE C CLASS (TATA/JINDAL) GAS PIPE (1.5" DIA) INCLUDING ALL MS SCH-40 SEAMLESS GRADE - ELBOWS, TEE'S, BARREL NIPPLES, ADAPTORS, NUTBOLTS, GASKETS. (APPROXIMATE LENGTH) Nos 225.00 0
3 1.5" DIA MAINLINE BALL VALVE (V&G /AUDCO "L&T" FIRE SAFE SERIES) Nos 5.00 0
4 1" DIA EQUIPMENT ISOLATION BALL VALVE (ITAP-ITALY ) AND HOSE PIPE FOR EACH EQUIPMENT 1.5 m LONG Nos 10.00 0
5 AUTOMATED SOLENOID GAS SHUTOFF VALVE WITH LOCKING MECHANISM AND MANUAL RESET FOR SAFETY. SIZE:1.5" MAKE: MADAS - ITALY Nos 1.00 0
6 SECOND STAGE PRESET PRESSURE REGULATOR WITH PRESSURE GUAGE WITH ISOLATION VALVE (UNITED / VANAZ) Nos 1.00 0
7 SUPPORTING CLAMPS 'M' TYPE/HANGING RODS/ "ANGULAR TYPE" Nos 1.00 0
8 MS FLANGE (1.5" DIA) GRADE "ASA" CLASS 150, FULL THICKNESS Nos 12.00 0
9 CHARGES FOR DRAWING OF 3D-ISOMETRIC LAYOUT OF ENTIRE GASLINE SYSTEM AS PER ACTUAL SIZES AND MEASUREMENT - ROUTINGS - GAS CONNECTIONS. Nos 1.00 0
10 PAINTING OF ENTIRE GAS PIPELINE ONLY WITH YELLOW OIL PAINT Nos 1.00 0
11 HIGH PRESSURE COMPRESSED AIR TESTING AS PER MAHANAGAR GAS (MGL) REQUIREMENTS & ISSUING OF TEST CERTIFCATE Nos 1.00 0
12 CHARGES FOR LABOUR AND INSTALLATION OF MS GAS PIPING AND ALL FITTINGS FOR PNG DISTRIBUTION SYSTEM Nos 220.00 0
13 Fitting Charges for Automated Solenoid Gas Shutoff Valve for Fire Suppression System Size:1.5", in our PNG Gas Pipeline INCLUDING COST OF BARREL NIPPLES, FLANGES, GASKETS, STUD NUTBOLTS, WELDING, TESTING, FIXING AND PAINTING. Nos 5.00 0
B GROUND FLOOR KITCHEN GLD
1 GAS LEAK DETECTION SYSTEM INSTALLATION INCLUDING, (A) GAS LEAK DETECTORS : 06 NOS (RANGE : 0-100% LEL FOR LPG, TYPE: CATALYTIC, DISPLAY : 7 SEGMENT LED COMPLETE WITH JUNCTION BOX & CABLE GLAND FLAME PROOF CERTIFIED FOR IIA & IIB [PESO CERTIFICATE / APPROVED]. (B) SMART ALARM PANEL CUM POWER SUPPLY WITH ZONE SEGREGATION AND INTEGRATED GSM MODULE WITH SIM CARD COMPATIBILITY. CAN BE CONFIGURED TO SEND SMS IN CASE OF LEAK DETECTION & ELECTRIC HOOTER. (C) CONNECTION OF ABOVE MENTION MATERIAL ON SITE (LDS) (D) CHARGES FOR ISSUING OF "FORM - A" FOR GAS LEAK DETECTION SYSTEM ONLY. Nos 1.00 0
GKK - 1 GROUND FLOOR KIOSK
GKK - 1.1 Work Table - 1500 x 650 x 900 + 100 Nos 1.00 0
GKK - 1.2 Bain Marie (GN 1/2 x 2) - 400 x 650 x 300 Nos 2.00 0
GKK - 1.3 Wall Cabinet - 1500 x 300 x 600 Nos 1.00 0
GKK - 1.4 Hot Holding Cabinet - 475 x 600 x 800 CORNELL HBC05S or equivalent Nos 1.00 0
GKK - 1.5 Cold Display Counter - 1200 x 750 x 1200 Nos 1.00 0
GKK - 1.6 Ambient Display Counter - 900 x 750 x 1200 Nos 1.00 0
GKK - 1.7 Work Table with 2 U/SH - 900 x 450 x 850 + 100 Nos 1.00 0
GKK - 1.8 Work Table With Sink on L.S.H & Bottom Storage - 1500 x 750 x 850 + 100 Nos 1.00 0
GKK - 1.9 Wall Shelf - 1500 x 350 Nos 1.00 0
GKK - 1.10 Induction Hub - 350 x 415 x 120 STELLA TS-3501 or equivalent Nos 1.00 0
GKK - 1.11 Sandwich Griller - 260 x 435 x 235 SIRMAN ELIO L - R or equivalent Nos 1.00 0
GKK - 1.12 Ice Cream Freezer - 900 x 700 x 850 TRUFROST CF 225 PREMIA Nos 1.00 0
GKK - 1.13 Wall Shelf - 600 x 500 Nos 1.00 0
GKK - 1.14 Microwave oven (Capacity 21 Liters) LG MC2186BG or equivalent Nos 1.00 0
GKK - 1.15 Visi Cooler - 1050 x 700 x 2000 ELANPRO ECG 775 Nos 1.00 0
21.2 VIP PANTRY
FVP - 1 DISH WASH
FVP - 1.1 Solid Dish Receving Table With Sink - 1200 x 750 x 900 + 100 Nos 1.00 0
FVP - 1.2 Pre Rinse Shower (Deck Mounted) T & S BRASS & BRONZE WORKS EX - 1DP00H or equivalent Nos 1.00 0
FVP - 1.3 Garbage Bin - 80 L Nilkamal WB80L or equivalent Nos 1.00 0
FVP - 1.5 Work Table - 750 x 750 x 900 + 100 Nos 1.00 0
FVP-1.6 Front Loading Dish Washer - 600 x 650 x 825 ELECTROLUX 400220 (ELA3G) or equivalent Nos 1.00 0
FVP - 1.7 Clean Dish Rack (5-Shelves) - 900 x 750 x 1650 Nos 1.00 0
FVP - 1.8 Insect Killer Technocrat Trapper or equivalent Nos 1.00 0
FVP - 1.9 Storage Cupbaord - 900 x 750 x 1650 Nos 1.00 0
FVP - 1.10 GN Size 2 Door Vertical Refrigerator 725 x 825 x 2050 - TRUFROST GN 680 TNM Nos 1.00 0
FVP - 1.11 Work Table with 2 U/SH - 900 x 750 x 850 + 100 Nos 1.00 0
FVP - 1.12 Wall Shelf - 900 x 350 Nos 1.00 0
FVP - 1.13 Hand Wash Sink with Soap Dispenser - 500 x 475 x 300 + 300 Nos 1.00 0
FVP - 1.14 S.S Insulated Partition - 900 x 75 x 1350 Nos 1.00 0
FVP-1.15 Water Softener - 314 x 446 x 739 PENTAIR PWCE16P12 or equivalent Nos 1.00 0
FVP - 2 PANTYRY
FVP - 2.2 Work Table with 2 U/SH - 950 x 600 x 850 + 100 Nos 1.00 0
FVP - 2.3 Work Table with 2 U/SH - 600 x 750 x 850 + 100 Nos 2.00 0
FVP - 2.4 S.S.Tandoor on Wheels (Electric Operated) - 750 x 750 x 1000 Nos 1.00 0
FVP - 2.5 Skewer Hanging Rod with drip box - 600 x 100 Nos 1.00 0
FVP - 2.6 Deep Fat Fryer (Twin Chember ) - 625 x 750 x 850 + 100 Nos 1.00 0
FVP - 2.8 Griddle Grill Plate - 600 x 750 x 850 + 100 Nos 1.00 0
FVP - 2.9 4 Induction Range - 750 x 750 x 850 + 100 Nos 1.00 0
FVP - 2.10 Stand For Combi Oven - 700 x 750 x 850 + 100 Nos 1.00 0
FVP - 2.11 Combi Oven - 641 x 655 x 567 RATIONAL ICP XS 6 2/3 Electric or equivalent Nos 1.00 0
FVP - 2.11A Combi Oven Accessories
A Baking Tray - 354 x 325 ZANUFF 2/3 GN Aluminium Baking Tray Nos 6.00 0
B Stainless Steel Tray - 354 x 325 ZANUFF 2/3 GN STAINLESS STEEL TRAY Nos 2.00 0
C Idli Tray (15 Idli) - 354 x 325 ZANUFF 2/3 GN 9 Idli Tray Nos 6.00 0
D Mini Idli Tray (60 Idli) - 354 x 325 ZANUFF 2/3 GN 42 Mini Idli Tray Nos 6.00 0
E Skewer Frame - 354 x 325 ZANUFF 2/3 GN Nos 3.00 0
F Skewer For The Tray -348 x 560 ZANUFF ROUND Nos 15.00 0
G Dhokla Tray - 354 x 325 ZANUFF 2/3 GN Nos 3.00 0
FVP - 2.12 Work Table with 2 U/SH - 1200 x 450 x 850 Nos 2.00 0
FVP - 2.13 Refrigerator Pickup counter with 2 OH/SH, Cabinet, R.R & KOT Printer Strip - 1350 x 600 x 850 + 450 + 375 + 200 TRUFROST GN 2100TN + CUSTOM or equivalent Nos 1.00 0
FVP - 2.14 Ice cream Freezer - 600 x 600 x 850 TRUFROST CF 225 PREMIA Nos 1.00 0
FVP - 2.15 Water Cooler - 80 L BLUE STAR SWC6080SS or equivalent Nos 1.00 0
FVP - 2.16 Staorage Rack (5 Shelves) - 900 x 450 x 1650 Nos 1.00 0
FVP - 2.17 Induction Hub - 350 x 415 x 120 STELLA TS-678 or equivalent Nos 6.00 0
FVP - 2.18 Work Table with 1 U/SH - 600 x 750 x 850 + 100 Nos 2.00 0
FVP - 3 EXHAUST HOOD
FVP - 3.1 S.S. Exhaust SINGLE Skin Hood with Filters -2125 x 900 x 500 Nos 1.00 0
FVP - 3.2 S.S. Exhaust SINGLE Skin Hood with Filters - 1500 x 900 x 500 Nos 1.00 0
FVP - 3.3 S.S. Exhaust SINGLE Skin Hood with Filters - 700 x 900 x 500 Nos 1.00 0
FVP - 3.4 Exhaust Grill for Hood Type Dish Wash (GV-1.6) - 300 x 200 Nos 1.00 0
FVP - 3.5 Fire Suppression System SWASTIC SYNERGY, CEASEFIR or equivalent
A Stainless Steel Wet Chemical Cylinder with Valve duly filled & Pressurized - 12 L Nos 1.00 0
A.1 Stainless Steel Wet Chemical Cylinder with Valve duly filled & Pressurized - 9 L Nos 1.00 0
B Manual Activation Pull Station Nos 2.00 0
C Automatic Mechanical Activation Panel Nos 2.00 0
D Multiple - Nozzle for Ranges Nos 7.00 0
E Multiple - Nozzle for Plenum and Duct Nos 5.00 0
F Fusible Links with Brackets Nos 7.00 0
G Corner Pulley Nos 16.00 0
H INSTALLATION Nos 3.00 0
FVP - 4 GRATING & CORNER GUARD
FVP - 4.1 S.S Grating - 600 x 300 Nos 4.00 0
FVP - 4.2 S/S Corner Guard - 2400 Ht. Nos 4.00 0
TOTAL OF KITCHEN EQUIPMENT 0
22.1 Drilling of perfectly vertical bore hole of 150 mm diameter up to desired depth belowground level including all works pertaining to drilling such as transportation, installationand removal of drilling machine etc. complete
22.1.a in all types of collapsible strata consisting of soil, clay, murum, gravel, boulders, etc Rmt 50.00 0
22.1.b in all types of rock Rmt 150.00 0
22.2 Providing and installing MS 150 dia casing pipes in position upto the required depth below ground level including cutting threading, coupling / welding, Rmt 50.00 0
22.3 Providing and installing Jindal / Tata make 50 dia GI pipes (B class) inclusive of all fittings complete Rmt 200.00 0
22.4 SITC of 10 HP 16 stage three phase submersible pump set inclusive of all accessories complete Nos 2.00 0
22.5 Providing and erecting ISI marked PVC insulated PVC Sheathed Flat flexible Submersible copper cable approved make of following Size. (e) 3 Core x 10 Sq. mm inclusive of all accessories complete Rmt 200.00 0
22.6 Supplying & erecting approved make motor control panel Nos 2.00 0
TOTAL OF BORE WELLS 0
23. FAÇADE WORK
23.1.1 WT-01 : Aluminium Vertical Sleek Suspended Glazing System with Glass Face Sealed Duly Coated with Hyper Durable Powder Coating. (Scope includes: supply of glazing system including all requisite hardware & accessories , fabrication and installation of the system and installation of glass (Glass cost excluded). Sqm 570.00 0
The scope of work includes the design, engineering, furnishing, fabrication, supply, delivery, packaging, protection, onsite water testing conducted in accordance with AAMA 501.2-25 along with installation of a complete Aluminium Vertical Sleek Suspended Glazing System at the main entrance glazing. This system will incorporate 37.52 mm thick high-performance laminated insulated glass units (IGUs) and shall be installed as part of the lobby glazing works. The glazing system shall be designed to withstand a design wind pressure of 1.8 Kpa and must successfully pass a proof load test at 1.5 times the design wind pressure (2.7 Kpa) without any failure. The system shall employ concealed fixings, with the glass panels offset from the structural Aluminium mullions to create a floating façade aesthetic devoid of horizontal transoms. This configuration ensures a sleek, uninterrupted visual appearance, both functionally and architecturally. Vertically, the glass shall be suspended from slim Aluminium mullions, which shall be coated with Hyper Durable Powder Coating in architect-approved RAL shades, with a minimum coating thickness of 50–90 microns, conforming to AAMA 2605 standards. The system will be suspended from the top, with engineered tolerances at floor level to accommodate thermal expansion, seismic movements, and dynamic wind loads. Dead load brackets shall be provided at mullion locations to support the weight of the glass units. The glass units shall be held on their vertical sides using mechanical toggles, spaced as per structural design. Dead loads will be transferred through concealed brackets at the bottom, connected to the vertical Aluminium members. Glass-to-glass joints shall be sealed using non-staining silicone sealant from an approved equivalent, with vertical joints recessed by 3 mm to enhance visual aesthetics.
The system shall remain completely free of floor-level contact, with a U-channel provided at both top and bottom to interface with false ceilings and floor finishes. Adequate provision for minimum 20 mm vertical movement shall be integrated to accommodate RCC slab or as advised by the structural engineer. The system must comply with performance standards for air tightness, water tightness, and structural stability, with all deflections within permissible limits. Performance testing shall be carried out at a NABL-accredited laboratory to validate compliance with design parameters, including seismic movement criteria. The quoted rate shall include all design approvals, engineering, shop drawings, and coordination with the architect and consultant. It shall also include the strengthening of the Aluminium gridwork, and the provision of structural connections required to mount the client’s branding signage as advised by the client.
BOQ Item shall be read in conjunction with Construction Performance Specification Section 08 44 26.16 (2.3 & 3.3) Section 07 21 00 ( 2.2) Section 07 92 00 Section 05 05 13 (2.2) Section 05 05 19.1 Section 07 13 00 Section 07 62 00 (2.2) Section 08 85 00
23.1.2 High-Performance Vision Glass : Extra over WT -01 (Scope includes Supply and delivery of High-Performance vision glass panels to site Cost Only) GL-01: 37.52mm Thick Single Laminated Insulated Glass Unit ( IGU) Consists Of 6mm Thick Extra Clear / Low Iron Heat Strengthened (HS) Outerlite + 1.52mm Thick Clear PVB Interlayer + 6mm thick Extra Clear / Low Iron Heat Strengthened (HS) Glass, such as Saint-Gobain SKN 183 or an approved equivalent, with the Low Emissivity ( Low-E) Performance coating applied on Surface # 4 + 16mm Thk 100 % Air Filled Gap with Black Spacer + 8mm Thick Extra Clear / Low Iron Fully Tempered (Heat Soak Test to reduce risk of spontaneous breakage) Innerlite Glass Unit . Base clear /coated glass shall be low iron (high- clarity) glass with iron content less than 120 parts per million (ppm), offering superior transparency and minimal colour distortion. Coated Glass shall be manufactured in accordance to EN 1096. Luminous & solar Characteristics are determined as per CIE015:2018/EN 410 standards. Thermal Transmittance is determined as per EN 673 standards. The IGU shall be factory-assembled by an approved glass processor and designed to ensure high optical clarity, durability, and thermal performance in accordance with relevant standards. Coated Glass are manufactured in accordance to EN 1096. Luminous & solar Characteristics are determined as per EN 410 standards. Thermal Transmittance is determined as per EN 673 standards. Rate shall be inclusive of Landing cost on site, Wastage , Breakage of the Glass and inclusive of packing cost. Sqm 570.00 0
BOQ Item shall be read in conjunction with Construction Performance Specification Section 08 81 23 (1.3)
23.1.3 Double Leaf Aluminium Framed Manual Swing Doors with Heavy Duty Floor Spring Integrated in Aluminium Vertical Sleek Suspended Glazing System: Door Opeining Size: 2000mm ( Width) x 2700mm ( Height) (Scope includes Glass Supply + System + Fabrication + Installation Cost) The scope includes the supply, fabrication, assembly, and installation of a Double Leaf Aluminium Door system constructed from 6063-T6 aluminium sections, finished with Hyper Durable Powder coating of minimum 50-90 microns compliant with AAMA 2605 standards.The door features 50 mm deep outer and vent frames with mitre-jointed corners, assembled using crimped, nailed, or screw-type cleats reinforced with metal adhesive. The vent frame overlaps the outer frame by 5 mm on three sides and is flush-fitted.Hardware includes all necessary gaskets, a 32 mm diameter satin stainless steel (Grade 316) offset pull handle, and a suitable locking mechanism supporting single or multi-point locking without visible profile changes.A heavy-duty floor spring system with adjustable EN 3 to EN 6 closing force, hydraulic hold-open (80°–165°), optional delayed closing, and back-check functions (EN 1154 tested) is provided, suitable for doors up to 1400 mm wide and 300 kg.All primary fixings use SS 316 star-head screws, with an M.S. insert plate supplied for the top pivot. The door includes a 24 mm thick fully toughened and heat-soak tested clear Insulated Glass Unit (IGU).The quoted rate covers complete supply, fabrication, delivery, installation, and all associated costs including hardware, packing, wastage, and compliance with technical specifications. Nos 13.00 0
BOQ Item shall be read in conjunction with Construction Performance Specification Section 08 81 23 (1.3)
23.2 Aluminium Punch – Fixed Window System Duly Coated with Hyper Durable Powder Coating : Scope includes: supply fo window system including all requisite hardware & accessories , fabrication and installation of the window system and installation of glass (Glass cost excluded) @ Lower Ground to 2nd Floor.
23.2.1 The scope includes the provision of a fully engineered Prefabricated Punch-Fixed Window System, covering the design, engineering, furnishing, fabrication, supply, packaging, delivery, onsite water testing, protection, and installation of a complete window assembly. The system comprises an Aluminium Outer Frame Profile, Aluminium Sash Frame Profile, and Aluminium Glazing Beading Clip Profile, all finished with a Hyper Durable Powder Coating in a RAL shade approved by the Architect, ensuring enhanced durability, weather resistance, and a cohesive aesthetic. The outer frame shall be securely anchored to the RCC structure using Mild Steel Omega or Z-brackets, fixed at specified intervals along the top and sides using Stainless Steel 316 Grade nuts and bolts, ensuring precise alignment and long-term structural stability. To enhance thermal and acoustic insulation, high-density Stone Mineral Wool (60 kg/m³) shall be installed around the frame perimeter (head and jambs), reducing energy loss and contributing to overall occupant comfort. At the sill level, the bottom edge of the outer frame shall be pre-fastened to the structural opening and subframe using S.S. 316 Grade pan head screws, silicone-dipped and installed with high-quality plastic plugs to prevent moisture ingress and mitigate galvanic corrosion from dissimilar materials. For long-term performance, the entire frame assembly shall be protected with a 1.2 mm thick Galvanized Iron (G.I.) primary seal and a 1.0 mm thick waterproofing membrane, together ensuring airtightness, water resistance, and façade envelope durability. Sqm 630.00 0
BOQ Item shall be read in conjunction with Construction Performance Specifications Section 08 51 53 ( 1.1.1.2 ,1.4, 2.1, 2.2,2.3.2.4) Section 07 92 00 Section 07 13 00 Section 08 85 00
23.2.2 High-Performance Vision Glass : Extra over WT -02 (Scope includes Supply and delivery of High-Performance vision glass panels to site Cost Only) GL-01: 37.52mm Thick Single Laminated Insulated Glass Unit ( IGU) Consists Of 6mm Thick Extra Clear / Low Iron Heat Strengthened (HS) Outerlite + 1.52mm Thick Clear PVB Interlayer + 6mm thick Extra Clear / Low Iron Heat Strengthened (HS) Glass, such as Saint-Gobain SKN 183 or an approved equivalent, with the Low Emissivity ( Low-E) Performance coating applied on Surface # 4 + 16mm Thk 100 % Air Filled Gap with Black Spacer + 8mm Thick Extra Clear / Low Iron Fully Tempered (Heat Soak Test to reduce risk of spontaneous breakage) Innerlite Glass Unit . Base clear /coated glass shall be low iron (high- clarity) glass with iron content less than 120 parts per million (ppm), offering superior transparency and minimal colour distortion.Coated Glass shall be manufactured in accordance to EN 1096. Luminous & solar Characteristics are determined as per CIE015:2018/EN 410 standards. Thermal Transmittance is determined as per EN 673 standards. The IGU shall be factory-assembled by an approved glass processor and designed to ensure high optical clarity, durability, and thermal performance in accordance with relevant standards. Coated Glass are manufactured in accordance to EN 1096. Luminous & solar Characteristics are determined as per EN 410 standards. Thermal Transmittance is determined as per EN 673 standards. Rate shall be inclusive of Landing cost on site, Wastage , Breakage of the Glass and inclusive of packing cost. Sqm 630.00 0
BOQ Item shall be read in conjunction with Construction Performance Specifications Section 08 81 23 (1.3)
23.2.3 Following to be carried out at no extra cost: Performance Mockup- Fixed Punch Window Wall Glazing (Tested by NABL Accredidated Laboratory) MODULE TYPE - Performance Mockup should include W-01: 1800mm x 4200mm (Civil Opening Size ). Testing standards: ASTM E 283-04, ASTM E 331-09, AAMA 501.1-105, ASTM E 330-10, Testing Specifications:Air Infiltartion Test/Water Penetration Test by Static Air Pressure Difference/ Water Penetration Test by Dynamic Air Pressure Difference/ Structural Performance Test by Static Air Pressure Difference/Structural Proof Load Test.
BOQ Item shall be read in conjunction with Construction Performance Specifications Section 08 51 53( 3.10) Section 07 21 00 ( 2.2) Section 07 92 00 Section 05 05 13 (2.2) Section 05 05 19.1 Section 07 13 00 Section 07 62 00 (2.2) Section 08 85 00
23.3 Aluminium Punch – Fixed Window System with Photo Frame Effect from inside Duly Coated with Hyper Durable Powder Coating: Scope includes: supply fo window system including all requisite hardware & accessories , fabrication and installation of the window system and installation of glass (Glass cost excluded).@ Ground to 2nd Floor.
23.3.1 The scope includes the provision of a fully engineered Prefabricated Punch-Fixed Window System, encompassing the design, engineering, furnishing, fabrication, supply, packaging, delivery, onsite water testing, protection, and installation of a complete window assembly. The system features a prefabricated configuration with a peripheral aluminium glazing bed profile, subtly inward-sloped to create a refined photo frame effect, contributing to both aesthetic appeal and water-shedding performance. The assembly comprises an Aluminium Outer Frame Profile, Aluminium Sash Frame Profile, and Aluminium Glazing Beading Clip Profile, all finished in Hyper Durable Powder Coating in a RAL shade approved by the Architect. This finish ensures enhanced durability, superior weather resistance, and a visually cohesive appearance across all exposed surfaces. The outer frame is securely anchored to the RCC structure using Mild Steel Omega or Z-Brackets, placed at architecturally defined intervals along the head and jambs, and fixed with Stainless Steel 316 Grade nuts and bolts to maintain precise alignment and long-term structural integrity. To enhance thermal and acoustic performance, high-density Stone Mineral Wool insulation (60 kg/m³) is installed around the frame perimeter at the head and jambs, effectively reducing energy loss and contributing to occupant comfort. At the sill level, the bottom edge of the outer frame is pre-fastened to the structural opening and subframe using S.S.316 Grade pan head screws, which are silicone-dipped and paired with high-quality plastic plugs to improve moisture resistance and prevent galvanic corrosion arising from dissimilar metal contact. For additional protection, the complete frame assembly is sealed with a 1.2 mm thick Galvanized Iron (G.I.) primary seal and a 1.0 mm thick waterproofing membrane, providing a robust barrier against air and water ingress, thereby ensuring the long-term durability of the façade envelope. Sqm 70.00 0
BOQ Item shall be read in conjunction with Construction Performance Specifications Section 08 51 53 ( 1.1.1.2 ,1.4, 2.1, 2.2,2.3.2.4) Section 07 92 00 Section 07 13 00 Section 08 85 00
23.3.2 High-Performance Vision Glass : Extra over WT-03 (Scope includes Supply and delivery of High-Performance vision glass panels to site Cost Only) GL-01: 37.52mm Thick Single Laminated Insulated Glass Unit ( IGU) Consists Of 6mm Thick Extra Clear / Low Iron Heat Strengthened (HS) Outerlite + 1.52mm Thick Clear PVB Interlayer + 6mm thick Extra Clear / Low Iron Heat Strengthened (HS) Glass, such as Saint-Gobain SKN 183 or an approved equivalent, with the Low Emissivity ( Low-E) Performance coating applied on Surface # 4 + 16mm Thk 100 % Air Filled Gap with Black Spacer + 8mm Thick Extra Clear / Low Iron Fully Tempered (Heat Soak Test to reduce risk of spontaneous breakage) Innerlite Glass Unit . Base clear /coated glass shall be low iron (high- clarity) glass with iron content less than 120 parts per million (ppm), offering superior transparency and minimal colour distortion. Coated Glass shall be manufactured in accordance to EN 1096. Luminous & solar Characteristics are determined as per CIE015:2018/EN 410 standards. Thermal Transmittance is determined as per EN 673 standards. The IGU shall be factory-assembled by an approved glass processor and designed to ensure high optical clarity, durability, and thermal performance in accordance with relevant standards. Coated Glass are manufactured in accordance to EN 1096. Luminous & solar Characteristics are determined as per EN 410 standards. Thermal Transmittance is determined as per EN 673 standards. Rate shall be inclusive of Landing cost on site, Wastage , Breakage of the Glass and inclusive of packing cost. Sqm 70.00 0
BOQ Item shall be read in conjunction with Construction Performance Specifications Section 08 81 23 (1.3)
23.4 Aluminium Punch – Fixed Window @ Connecting Bridge, System Duly Coated with Hyper Durable Powder Coating : Scope includes: supply fo window system including all requisite hardware & accessories , Stone Mineral Wool Insulation,Aluminium Tray , Aluminium Sheet Flashing fabrication and installation of the window system and installation of glass (Glass cost excluded)@ Ground to 2nd Floor- Connecting Bridge.
23.4.1 The scope includes the provision of a fully engineered Prefabricated Punch-Fixed Window System, covering the design, engineering, furnishing, fabrication, supply, packaging, delivery, onsite water testing, protection, and installation of a complete window assembly. The system comprises an Aluminium Outer Frame Profile, Aluminium Sash Frame Profile, and Aluminium Glazing Beading Clip Profile, all finished with a Hyper Durable Powder Coating in a RAL shade approved by the Architect, ensuring enhanced durability, weather resistance, and a cohesive aesthetic. The outer frame shall be securely anchored to the M.S. structure using hex-head, self-tapping screws with silicone dipped coating, installed with high-quality plastic plugs at specified intervals along the top, bottom, and all sides, ensuring precise alignment and long-term structural stability.. Additionally, the scope of work includes the supply and installation of a shadow box within the spandrel panel behind the spandrel glass. The shadow box assembly shall comprise a 2.0 mm thick solid Aluminium sheet cover, combined with tested stone mineral wool insulation having a minimum density of 64 kg/m³ and a minimum thickness of 50 mm. The stone mineral wool insulation shall be firmly secured within a 2.0 mm thick Aluminium supporting tray, which will be visible from the interior, and shall be provided at all spandrel areas, particularly at beam locations, as indicated in the façade tender drawings. The insulation slabs shall be rigidly fixed to the G.I. tray using specialized fixing pins to ensure long-term stability. Both the exposed spandrel back pans located behind the spandrel glass and the supporting trays visible from the interior shall be fabricated from 2.0 mm thick Aluminium sheet, manufactured from 3xxx series Aluminium alloy with temper H14 or H16. Sqm 775.00 0
The Aluminium trays shall be SDP powder-coated with a minimum coating thickness of 60-80 microns, in compliance with AAMA 2604 standards. All shadow box assemblies shall be offset to align with the transom sightlines in accordance with the approved design intent and shall include a continuous perimeter seal to ensure proper performance and finish.The scope of work shall also include the supply, fabrication, and installation of pre-coated solid aluminium sheet flashing at the top of the aluminium punch window, finished with a 3-layer PVDF coating of minimum 35–40 microns, in full compliance with AAMA 2605 standards. The aluminium sheet flashing at the top fo the Punch window shall be securely fixed to a supporting aluminium framework, which is mounted onto a hot-dip galvanized mild steel structure ( by others) using stainless steel nuts and bolts. The aluminium sheets shall be mechanically fixed to the aluminium framing system using grooved and bent panels, reinforced with corner cleats, and secured with Grade 316 stainless steel screws. Approved clips and rivets shall also be used to ensure proper alignment and stability, while allowing defined vertical and horizontal grooves to accommodate thermal expansion.An EPDM waterproofing membrane along with 1.2mm Thk G.I. Sheet primary seal shall be installed beneath the panels to ensure both structural integrity and long-term water resistance. All panel joints shall be sealed with a high-performance, weather-grade silicone sealant, applied as a continuous bead along the entire length of each joint to form a watertight barrier, effectively preventing water ingress and enhancing the overall durability and weather resistance of the cladding system.
BOQ Item shall be read in conjunction with Construction Performance Specifications Section 08 51 53 ( 1.1.1.2 ,1.4, 2.1, 2.2,2.3.2.4) Section 07 92 00 Section 07 13 00 Section 08 85 00
23.4.2 Aluminium Fixed Window @ Eleptical building and admin office, System Duly Coated with Hyper Durable Powder Coating : Scope includes: supply fo window system including all requisite hardware & accessories , Stone Mineral Wool Insulation,Aluminium Tray , Aluminium Sheet Flashing fabrication and installation of the window system and installation of glass (Glass cost excluded)@ Ground to 2nd Floor- Connecting Bridge. The scope includes the provision of a fully engineered Prefabricated Punch-Fixed Window System, covering the design, engineering, furnishing, fabrication, supply, packaging, delivery, onsite water testing, protection, and installation of a complete window assembly. The system comprises an Aluminium Outer Frame Profile, Aluminium Sash Frame Profile, and Aluminium Glazing Beading Clip Profile, all finished with a Hyper Durable Powder Coating in a RAL shade approved by the Architect, ensuring enhanced durability, weather resistance, and a cohesive aesthetic. The outer frame shall be securely anchored to the M.S. structure using hex-head, self-tapping screws with silicone dipped coating, installed with high-quality plastic plugs at specified intervals along the top, bottom, and all sides, ensuring precise alignment and long-term structural stability.. Additionally, the scope of work includes the supply and installation of a shadow box within the spandrel panel behind the spandrel glass. The shadow box assembly shall comprise a 2.0 mm thick solid Aluminium sheet cover, combined with tested stone mineral wool insulation having a minimum density of 64 kg/m³ and a minimum thickness of 50 mm. The stone mineral wool insulation shall be firmly secured within a 2.0 mm thick Aluminium supporting tray, which will be visible from the interior, and shall be provided at all spandrel areas, particularly at beam locations, as indicated in the façade tender drawings. The insulation slabs shall be rigidly fixed to the G.I. tray using specialized fixing pins to ensure long-term stability. Both the exposed spandrel back pans located behind the spandrel glass and the supporting trays visible from the interior shall be fabricated from 2.0 mm thick Aluminium sheet, manufactured from 3xxx series Aluminium alloy with temper H14 or H16. Sqm 50.00 0
The Aluminium trays shall be SDP powder-coated with a minimum coating thickness of 60-80 microns, in compliance with AAMA 2604 standards. All shadow box assemblies shall be offset to align with the transom sightlines in accordance with the approved design intent and shall include a continuous perimeter seal to ensure proper performance and finish.The scope of work shall also include the supply, fabrication, and installation of pre-coated solid aluminium sheet flashing at the top of the aluminium punch window, finished with a 3-layer PVDF coating of minimum 35–40 microns, in full compliance with AAMA 2605 standards. The aluminium sheet flashing at the top fo the Punch window shall be securely fixed to a supporting aluminium framework, which is mounted onto a hot-dip galvanized mild steel structure ( by others) using stainless steel nuts and bolts. The aluminium sheets shall be mechanically fixed to the aluminium framing system using grooved and bent panels, reinforced with corner cleats, and secured with Grade 316 stainless steel screws. Approved clips and rivets shall also be used to ensure proper alignment and stability, while allowing defined vertical and horizontal grooves to accommodate thermal expansion.An EPDM waterproofing membrane along with 1.2mm Thk G.I. Sheet primary seal shall be installed beneath the panels to ensure both structural integrity and long-term water resistance. All panel joints shall be sealed with a high-performance, weather-grade silicone sealant, applied as a continuous bead along the entire length of each joint to form a watertight barrier, effectively preventing water ingress and enhancing the overall durability and weather resistance of the cladding system.
BOQ Item shall be read in conjunction with Construction Performance Specifications Section 08 51 53 ( 1.1.1.2 ,1.4, 2.1, 2.2,2.3.2.4) Section 07 92 00 Section 07 13 00 Section 08 85 00
23.4.3 High-Performance Vision Glass : Extra over WT-04 (Scope includes Supply and delivery of High-Performance vision glass panels to site Cost Only) @ connecting bridge GL-01: 37.52mm Thick Single Laminated Insulated Glass Unit ( IGU) Consists Of 6mm Thick Extra Clear / Low Iron Heat Strengthened (HS) Outerlite + 1.52mm Thick Clear PVB Interlayer + 6mm thick Extra Clear / Low Iron Heat Strengthened (HS) Glass, such as Saint-Gobain SKN 183 or an approved equivalent, with the Low Emissivity ( Low-E) Performance coating applied on Surface # 4 + 16mm Thk 100 % Air Filled Gap with Black Spacer + 8mm Thick Extra Clear / Low Iron Fully Tempered (Heat Soak Test to reduce risk of spontaneous breakage) Innerlite Glass Unit . Base clear /coated glass shall be low iron (high- clarity) glass with iron content less than 120 parts per million (ppm), offering superior transparency and minimal colour distortion..Coated Glass shall be manufactured in accordance to EN 1096. Luminous & solar Characteristics are determined as per CIE015:2018/EN 410 standards. Thermal Transmittance is determined as per EN 673 standards. The IGU shall be factory-assembled by an approved glass processor and designed to ensure high optical clarity, durability, and thermal performance in accordance with relevant standards. Coated Glass are manufactured in accordance to EN 1096. Luminous & solar Characteristics are determined as per EN 410 standards. Thermal Transmittance is determined as per EN 673 standards. Rate shall be inclusive of Landing cost on site, Wastage , Breakage of the Glass and inclusive of packing cost. Sqm 825.00 0
BOQ Item shall be read in conjunction with Construction Performance Specifications Section 08 81 23 (1.3)
23.4.4 High-Performance Vision Glass with Ceramic Fritting : Extra over WT-04 (Scope includes Supply and delivery of High-Performance vision glass panels to site Cost Only) @ Connecting Bridge GL-01A: 37.52mm Thick Single Laminated Insulated Glass Unit ( IGU) Consists Of 6mm Thick Extra Clear / Low Iron Heat Strengthened (HS) Outerlite Glass with 100 % opacity ceramic frit applied on Surface # 1 with Ceramic Ink Integrated iwth Electromagnetic Drive Technology + 1.52mm Thick Clear PVB Interlayer + 6mm thick Extra Clear / Low Iron Heat Strengthened (HS) Glass, such as Saint-Gobain SKN 183 or an approved equivalent, with the Low Emissivity ( Low-E) Performance coating applied on Surface # 4 + 16mm Thk 100 % Air Filled Gap with Black Spacer + 8mm Thick Extra Clear / Low Iron Fully Tempered (Heat Soak Test to reduce risk of spontaneous breakage) Innerlite Glass Unit , All base clear and coated glass shall be low-iron, high-clarity glass with an iron content not exceeding 120 parts per million (ppm), providing superior transparency and minimal color distortion. The ceramic ink shall be applied using advanced digital ceramic printing methods and permanently fused into the glass substrate during the tempering process, forming an integral, non-removable, and weather-resistant finish. Printing shall utilize Electromagnetic Drive Technology to achieve ultra-precise ink deposition and pattern control, ensuring uniform coverage, sharp resolution, optimal adhesion, long-term durability, color stability, and resistance to fading, peeling, or delamination under exterior exposure conditions.Coated Glass shall be manufactured in accordance to EN 1096. Luminous & solar Characteristics are determined as per CIE015:2018/EN 410 standards. t. Sqm 75.00 0
Thermal Transmittance is determined as per EN 673 standards. The IGU shall be factory-assembled by an approved glass processor and designed to ensure high optical clarity, durability, and thermal performance in accordance with relevant standards. Coated Glass are manufactured in accordance to EN 1096. Luminous & solar Characteristics are determined as per EN 410 standards. Thermal Transmittance is determined as per EN 673 standards. Rate shall be inclusive of Landing cost on site, Wastage , Breakage of the Glass and inclusive of packing cos
BOQ Item shall be read in conjunction with Construction Performance Specifications Section 08 81 23 (1.3)
23.5 WT-04A : Stick Curtain Wall Inclined Glazing System featuring high-performance glass panels mounted on structurally robust framework of steel mullions and transoms, externally cladded with precision-finished with S.S. 316 Grade Stainless-Steel complimented by Aluminium Pressure Plate & Cover Cap Duly Coated with Hyper Durable Powder Coating.
23.5.1 The scope of work includes the design, engineering, supply, fabrication, delivery, installation, and commissioning of a complete Stick Curtain Wall Inclined Glazing System. This system shall consist of high-performance glass panels supported on structurally robust mild steel (M.S.) mullions and transoms. The steel framing shall be externally cladded with precision-finished stainless steel cover profiles with Double-sided 3mm thick structural tape reinforces glass-to-frame adhesion, to deliver a durable, sleek, and architecturally expressive façade.. The steel framework provides structural support at the top, bottom, and lateral edges of the glazing system, forming a lightweight façade that effectively separates the external environment from the interior of the building while facilitating optimal natural daylight penetration, as illustrated in the tender drawings. Each glass panel shall be mechanically fixed to the structural framework using precision-engineered Aluminium pressure plates. These plates will apply a uniform clamping force, ensuring accurate alignment and secure retention of the glazing units. This fixing method contributes to the system’s structural integrity, weather resistance, and long-term performance. To achieve a refined architectural finish, Aluminium cover caps shall be installed over the pressure plates, effectively concealing all mechanical fasteners such as bolts and nuts. These caps shall be seamlessly integrated into the curtain wall design, enhancing its visual continuity and providing additional environmental protection. Sqm 615.00 0
The complete system shall be engineered to ensure Mechanical reliability through robust structural anchoring, superior air- and water-tightness, Durability under diverse environmental conditions, Ease of maintenance access, and architectural sophistication with a clean, uninterrupted visual expression. All system components shall be delivered to site in a fully protected condition, thoroughly field-tested, and installed in full compliance with the approved shop drawings, manufacturer’s specifications, and under the strict supervision of the Engineer-in-Charge.
BOQ Item shall be read in conjunction with Construction Performance Specifications Section 08 44 23 ( 2.1-D,E & F, 2.2) Section 07 21 00 ( 2.2) Section 07 84 53 Section 07 92 00 Section 05 05 13 (2.2) Section 05 05 19 Section 07 13 00 Section 07 62 00 (2.2) Section 08 85 00
23.5.2 High-Performance Vision Glass : Extra over WT-04A (Scope includes Supply and delivery of High-Performance vision glass panels to site Cost Only) GL-01: 37.52mm Thick Single Laminated Insulated Glass Unit ( IGU) Consists Of 6mm Thick Extra Clear / Low Iron Heat Strengthened (HS) Outerlite + 1.52mm Thick Clear PVB Interlayer + 6mm thick Extra Clear / Low Iron Heat Strengthened (HS) Glass, such as Saint-Gobain SKN 183 or an approved equivalent, with the Low Emissivity ( Low-E) Performance coating applied on Surface # 4 + 16mm Thk 100 % Air Filled Gap with Black Spacer + 8mm Thick Extra Clear / Low Iron Fully Tempered (Heat Soak Test to reduce risk of spontaneous breakage) Innerlite Glass Unit . Base clear /coated glass shall be low iron (high- clarity) glass with iron content less than 120 parts per million (ppm), offering superior transparency and minimal colour distortion. Coated Glass shall be manufactured in accordance to EN 1096. Luminous & solar Characteristics are determined as per CIE015:2018/EN 410 standards. Thermal Transmittance is determined as per EN 673 standards. The IGU shall be factory-assembled by an approved glass processor and designed to ensure high optical clarity, durability, and thermal performance in accordance with relevant standards. Coated Glass are manufactured in accordance to EN 1096. Luminous & solar Characteristics are determined as per EN 410 standards. Thermal Transmittance is determined as per EN 673 standards. Rate shall be inclusive of Landing cost on site, Wastage , Breakage of the Glass and inclusive of packing cost. Sqm 600.00 0
BOQ Item shall be read in conjunction with Construction Performance Specifications Section 08 81 23 (1.3)
23.5.3 High-Performance Spandrel Glass : Extra over WT-04A (Scope includes Supply and delivery of High-Performance vision glass panels to site Cost Only) GL-01: 37.52mm Thick Single Laminated Insulated Glass Unit ( IGU) Consists Of 6mm Thick Extra Clear / Low Iron Heat Strengthened (HS) Outerlite + 1.52mm Thick Clear PVB Interlayer + 6mm thick Extra Clear / Low Iron Heat Strengthened (HS) Glass, such as Saint-Gobain SKN 183 or an approved equivalent, with the Low Emissivity ( Low-E) Performance coating applied on Surface # 4 + 16mm Thk 100 % Air Filled Gap with Black Spacer + 8mm Thick Extra Clear / Low Iron Fully Tempered (Heat Soak Test to reduce risk of spontaneous breakage) Innerlite Glass Unit . Base clear /coated glass shall be low iron (high- clarity) glass with iron content less than 120 parts per million (ppm), offering superior transparency and minimal colour distortion. Coated Glass shall be manufactured in accordance to EN 1096. Luminous & solar Characteristics are determined as per CIE015:2018/EN 410 standards. Thermal Transmittance is determined as per EN 673 standards. The IGU shall be factory-assembled by an approved glass processor and designed to ensure high optical clarity, durability, and thermal performance in accordance with relevant standards. Coated Glass are manufactured in accordance to EN 1096. Luminous & solar Characteristics are determined as per EN 410 standards. Thermal Transmittance is determined as per EN 673 standards. Rate shall be inclusive of Landing cost on site, Wastage , Breakage of the Glass and inclusive of packing cost. Sqm 15.00 0
BOQ Item shall be read in conjunction with Construction Performance Specifications Section 08 81 23 (1.3)
23.5.4 Following to be carried out at no extra cost: Performance Mockup- Stick Curtain Wall Inclined Glazing System (Tested by NABL Accredidated Laboratory) MODULE TYPE - Performance Mockup should include 3 Nos. of modules , each measuring 1770mm (Width) X Height for Glazing (Varies). Testing standards: ASTM E 283-04, ASTM E 331-09, AAMA 501.1-105, ASTM E 330-10, AAMA 501.4-09, BS EN 14019, AS/NZS 4284.AAMA 501.4 Testing Specifications:Air Infiltartion Test/Water Penetration Test by Static Air Pressure Difference/ Water Penetration Test by Dynamic Air Pressure Difference/ Structural Performance Test by Static Air Pressure Difference/ Structural Proof Load Test/Thermal Cycling/Impact Resistance Test/ Seal Degradation Test.
BOQ Item shall be read in conjunction with Construction Performance Specifications Section 08 44 `13( 3.4) Section 07 21 00 ( 2.2) Section 07 92 00 Section 05 05 13 (2.2) Section 05 05 19.1 Section 07 13 00 Section 07 62 00 (2.2) Section 08 85 00
23.6 WT-05A : Type-01: Cleft Stone Cladding with Sweep Anchors (Heavy Stone Panel Fixing)– Open-Joint Ventilated Rainscreen Principle @ Lower Ground to Terrace Level: The scope covers the supply and installation of a complete cladding system, including all necessary hardware, accessories, and support framework. It includes the application of EPDM membrane (self-adhesive or with bonding adhesive), stone mineral wool insulation, and a fluid-applied air and vapour barrier over the insulation. The work also involves the fabrication and installation of the cladding system, along with installation of natural stone panels. Note: the cost of natural stone material is excluded; only installation is included.
23.6.1 The scope of work includes the design, engineering, fabrication, packaging, delivery, and installation of a complete dry-fix stone cladding system based on the open-joint ventilated rainscreen principle, utilizing a hook-on concealed fixing system. The system shall be engineered to withstand a design wind pressure of 1.8 Kpa in accordance with IS 875 (Part 3): 2015. The cladding system consists of continuous vertical Aluminium channel profiles, which include cut-outs to accommodate horizontal Aluminium diverters/gutters, stainless steel (S.S.) U-type support brackets, thermal isolators, and stainless steel (S.S.) L-angle profiles. As part of the installation methodology, the ventilated rainscreen system shall ensure controlled ventilation, effective moisture management, and enhanced thermal performance of the building envelope, while maintaining clean exterior aesthetics with no visible fasteners. As part of the installation methodology, Stainless Steel 304 Grade U-type brackets shall be securely anchored to the reinforced cement concrete (R.C.C.) wall using ETA approved anchor fasteners, ensuring long-term stability. This assembly shall form a durable support system for transferring structural loads from extruded Aluminium vertical channel profiles to the R.C.C. structure. The cladding assembly shall comprise continuous vertical extruded Aluminium channel profiles /Gutters incorporating precision-cut openings to accommodate horizontal Aluminium diverters/gutters, along with pre-fixed S.S.304 Grade vertical L-angle Bracket to facilitate the hook-on mechanism. The extruded Aluminium channel profiles /Gutters used for load transfer shall be mechanically fastened to the Stainless Steel 304 grade U-type brackets using SS 316 grade nuts and bolts with serrated washers, ensuring long-term corrosion resistance and mechanical stability. Each stone panel shall then be prepared with rear-drilled undercut holes and fitted with expansion sleeves or threaded inserts to ensure mechanical stability and long-term performance. ETA-approved A4-grade stainless steel sweep anchors shall be inserted into the prepared undercut holes. The anchor shall be lightly tapped with a soft-faced hammer to seat the expansion sleeve fully into the undercut zone and to align the cone for proper expansion, taking care not to over-tap. The S.S.304 Grade L-angle bracket shall then be positioned over the anchor hole on the stone panel, and the bolt shall be inserted through the bracket into the anchor thread. The anchor shall be tightened using a calibrated torque wrench to the specified torque—approximately 10 Nm for M8 anchors—so that the cone engages the sleeve, achieving full expansion and securely clamping the L-bracket against the stone surface. Once the fabrication is complete, the anchored stone panels shall subsequently be hung onto the vertical Aluminium channel profiles/Gutter profiles using the pre-fitted S.S.304 Grade L-angle bracket, ensuring secure, accurate, and precise placement. Sqm 19,480.00 0
A continuous ventilated cavity of not less than 90 mm shall be maintained behind the cladding to promote natural air circulation, moisture control, and improved thermal performance, in compliance with IS 4101 (Part 1) and relevant DIN standards for ventilated façade systems. Open joints of 15 mm shall be maintained between adjacent stone panels to accommodate thermal expansion and contraction due to temperature variations. This provision allows free movement of the stone panels and prevents cracking or damage. No silicone sealants shall be used within the joints, thereby preserving both the visual uniformity and functional performance of the open-joint system. All horizontal joints of stone panels at wall terminations shall be sealed with high-performance, UV-resistant, weather-grade silicone sealant that is non-staining and non-bleeding, ensuring long-lasting protection against weather and environmental effects. Installation shall be carried out strictly in accordance with the approved shop drawings and under continuous site engineering supervision to ensure accurate alignment, workmanship quality, and compliance with design intent. Teflon, nylon, or PVC separators shall be installed at all points of contact between dissimilar metals to prevent bi-metallic corrosion and ensure long-term durability. Separators shall be of adequate thickness, durability, and compatibility with Aluminium, and shall be installed in a manner that does not interfere with the performance or appearance of the system.
All extruded Aluminium components shall be manufactured from Aluminium alloy 6063-T6 in accordance with ASTM B221M. The complete cladding system shall be designed to withstand wind loads in accordance with IS 875 (Part 3): 2015 and other applicable international standards. Extruded Aluminium vertical channels/gutters shall be finished with a super-durable powder coating with a thickness of 60–80 microns, complying with AAMA 2604 requirements and in colours approved by the Architect. All concealed Aluminium surfaces including extruded Aluminium tubes supporting the top of Stone Panel shall be finished with a chrome-free pre-treatment primer coating. All brackets, screws, bolts, nuts, and anchor fasteners shall be of SS 316 grade and installed strictly in accordance with the approved design drawings, construction documents, and structural calculations. Each stone panel shall be cut to size and anchored using ETA-approved A4-grade stainless steel sweep anchors with CABR 1:1 seismic certification, ensuring compliance with international standards for structural integrity, corrosion resistance, and seismic performance.
All drilling, hole cleaning, and anchor installation procedures shall strictly follow the undercut anchor manufacturer’s guidelines. Calibrated portable drilling machines, compatible drill bits, and depth gauges shall be used to achieve the specified hole diameter, depth, and undercut geometry. Multiple Pull-out tests shall be conducted on installed sweep anchors using actual stone samples. The test results shall be used to determine the optimal sweep anchor spacing and the number of anchors per panel, ensuring safe load transfer and adequate safety margins. All components, including sweep anchors and mechanical expansion fasteners, shall be ETA-certified and supported by engineering design reports and structural software analysis, ensuring compliance with local codes and standards related to wind load resistance, seismic performance, and long-term safety. The stone slabs shall be fabricated precisely to the shapes and dimensions indicated in the approved drawings, ensuring weather tightness, aesthetic consistency, and compatibility with natural stone materials. All fabrication and installation activities shall strictly follow the approved shop drawings, with all tolerances carefully maintained to prevent misalignment, undue stress, or deformation of any façade element, thereby ensuring long-term structural integrity and system performance. Complete shop drawings, along with software-generated structural calculation reports, shall be submitted by the manufacturer’s design team or contractor to the Consultant for review and approval prior to commencement of installation.
Application of EPDM Membrane (either self-adhesive or with Low-VOC bonding adhesive) on External Cavity R.C.C. Wall_ Behind Stone Panel: The scope of work involves the provision and installation of a high-performance EPDM membrane, either self-adhesive or applied using a low-VOC bonding adhesive. This membrane is intended for use in weatherproof and watertight sealing applications on wall surfaces and must fully comply with EN 13984 standards. The selected membrane shall exhibit superior mechanical integrity, characterized by high flexibility and tear resistance, enabling it to accommodate thermal and structural movements within building assemblies. It must be resistant to ultraviolet radiation, capable of withstanding extreme temperature fluctuations, and impervious to chemical pollutants and moisture ingress. Installation may be executed using either self-adhesive application or bonding with adhesive, ensuring secure and durable placement. To guarantee long-term performance and reliability, the membrane shall meet the following technical criteria: a minimum tensile strength of 5 MPa and an elongation at break of at least 350%, as per EN 12311-2; a nail tear strength of no less than 70 N, tested in accordance with EN 13984; and a Shore A hardness rating of 50 or higher, verified according to ISO 7619. Additionally, the membrane must pass water tightness testing at 2 kPa, as specified in EN 1928. These performance benchmarks confirm the membrane’s suitability for creating resilient, airtight, and weatherproof seals in demanding construction environments.
Vertical Firestopping, Thermal & Acoustic Stone Mineral Wool Insulation System with Fluid Applied Air & Weather Barrier Coating over Stone Mineral Wool Insulation behind Stone Cladding @ R.C.C. Wall : The scope of work includes the supply and installation of a typical vertical firestopping, thermal, and acoustic insulation system located behind the stone cladding at dead wall areas, in accordance with the façade tender drawings. This system involves the installation of tested stone mineral wool insulation, with a minimum density of 120 kg/m³ and a minimum thickness of 50 mm, fixed directly onto the RCC wall using SS 316-grade stainless steel screws. The mineral wool slabs shall be securely held in place using specially designed fixing pins to ensure long-term stability and optimal performance. Over the insulation layer, a 100% silicone-based, vapour-permeable, fluid-applied air and weather barrier coating shall be applied to establish a continuous, protective envelope. This coating is engineered to resist air infiltration and water penetration while allowing water vapour to escape, thereby enhancing internal moisture management within the façade assembly. It must be UV-resistant and capable of withstanding prolonged exposure to sunlight, precipitation, and extreme temperatures without performance degradation. The manufacturer shall provide project-specific guidance, including the recommended dry film thickness, and must offer a warranty that ensures long-term performance and material compatibility when applied over mineral wool insulation. The complete system shall deliver high standards of fire resistance, thermal insulation, acoustic control, and weatherproofing, ensuring a durable and compliant façade solution.
BOQ Item shall be read in conjunction with Construction Performance Specifications Section 04 42 00 Section 05 05 13 ( 2.2) Section 07 62 00 Section 07 92 00 Section 07 27 26
23.6.2 Following to be carried out at no extra cost: System: WT-05A: Cleft Stone Cladding with Sweep Anchors (Heavy Stone Panel Fixing) Module Type: The PMU shall comprise a minimum of 5 stone panels (width) x 3 stone panels (height). Individual Panel Size (for PMU): 660 mm (Width) x 1750 mm (Height). Stone Thickness (for PMU): 35 mm Thick Cleft Limestone (or as per project stone specification). Testing Specifications: Ultimate Wind Load Testing/ Impact Resistance Test (Blunt Body Impact)/Thermal Cycling/Anchor Pull Out Test/Panel Ultimate Load/Break Test/Seismic & Dynamic Testing
BOQ Item shall be read in conjunction with Construction Performance Specifications Section 04 42 00-11 (3.7)
23.6.3 Following to be carried out at no extra cost: Chemical Composition of Limestone -Wet Analysis (Tested by NABL-National Accreditation Board for Testing and Calibration Laboratories) Laboratory Limestone's chemical composition shall be determined by a third-party laboratory through classical wet chemical analysis carried out by a NABL (National Accreditation Board for Testing and Calibration Laboratories) accredited facility, ensuring high accuracy and compliance with applicable quality standards. The analysis involves dissolving the sample in acid, followed by component-specific methods. Silica (SiO₂) is determined gravimetrically, while Iron Oxide (Fe₂O₃) and Alumina (Al₂O₃) are measured using titration or colorimetric methods. Calcium Oxide (CaO) and Magnesium Oxide (MgO) are analyzed via complexometric titration using EDTA. Chlorides (Cl) are quantified through argentometric titration, and Loss on Ignition (LOI) is determined by heating the sample to assess the volatile matter content. These analyses are essential to confirm that the limestone meets the required quality criteria for use in industrial, construction, or manufacturing applications. All testing shall be performed in accordance with the relevant IS/ASTM standards, as applicable.
BOQ Item shall be read in conjunction with Construction Performance Specifications Section 04 42 00-11 (3.8)
23.6.4 Stone ( Natural Stone- Cleft Limestone) : Extra over WT-05A (The scope encompasses the supply and site delivery of natural stone, with all six sides of each unit treated using a nano-based hydrophobic impregnating sealer) M-01: The scope includes the supply of 35mm thick Cleft, limestone , with surface finishes such as Honed, Sandblasted, River Wash, or Brushed, as approved by the Architect/Client crafted through the process of cleaving or splitting the stone along its inherent layers. The rate shall encompass cutting the limestone to the required dimensions as per approved drawings, including allowances for wastage, and providing 3mm thick CNC-cut chamfered edges on all exposed sides. The scope further includes the application of an approved nano-based hydrophobic impregnating sealer for water repellency, which shall not alter the natural colour of the stone. The sealer is to be applied in two coats on the front face, rear & four edges, strictly in accordance with the manufacturer’s specifications. Prior to application, the limestone surface shall be cleaned using a brush or roller, wiped with a moist cloth, and thoroughly dried to ensure adequate surface preparation. The application shall be carried out uniformly to ensure effective protection against stains, discoloration, and efflorescence while preserving the natural appearance of the stone. The quoted rate shall be inclusive of all associated components, including the landed cost of stone at site, transportation, handling, unloading, cutting, wastage, edging, polishing, and sealing treatment for surface protection, as well as shaping the stone in accordance with the tender drawings. All works shall be executed under the supervision of the Engineer-in-Charge and strictly adhere to the approved methodology and relevant product data sheets. Sqm 19,480.00 0
BOQ Item shall be read in conjunction with Construction Performance Specifications Section 04 42 00-3/4 (2.2)
23.7 WT-05B : Type-02: Cleft Stone Cladding with Undercut Anchors ( Medium Stone Panel Fixing on Beam Cladding) - (Pergola @ VIP Lounge): The scope covers the supply and installation of a complete cladding system, including all necessary hardware, accessories, and support framework. The work also involves the fabrication and installation of the cladding system, along with installation of natural stone panels. Note: the cost of natural stone material is excluded; only installation is included.
23.7.1 The scope includes the design, engineering, supply, fabrication, packaging, delivery, and installation of a complete dry-fix cleft stone cladding system, utilizing the open joint ventilated rainscreen principle and engineered to withstand a design wind pressure of 1.8 kPa. The system comprises an ETA-approved, fully designed one-stop solution for dry stone cladding applications, which includes wall anchors, a precision-engineered subframe, and undercut anchors for stone panels. The ventilated façade kit consists of a complete assembly of Aluminium subframes and fastening systems for the stone cladding, including wall brackets, thermal isolators, connectors, hanger profiles, hangers, L- or T-shaped Aluminium support profiles, and all necessary panel fixing elements. Rear-drilled undercut holes with expansion sleeves or threaded dowels. This integrated system ensures mechanical stability, durability, and long-term performance, offering a technically sound and aesthetically clean façade solution. A 15mm gap is maintained between stone panels for expansion and contraction due to temperature fluctuations, allowing free movement to prevent cracking or damage. High-performance non-staining and non-bleeding weather silicone is applied to open joints to maintain effective joint function and protect the stone appearance and performance. The system ensures mechanical stability, durability, and long-term performance with aesthetically clean façades. Installation is executed per approved shop drawings, with site engineering supervision to monitor quality and alignment. Sqm 140.00 0
BOQ Item shall be read in conjunction with Construction Performance Specifications Section 04 42 00 Section 05 05 13 ( 2.2) Section 07 62 00 Section 07 92 00 Section 07 27 26
23.7.2 Stone ( Natural Stone- Cleft Limestone) : Extra over WT-05B (The scope encompasses the supply and site delivery of natural stone, with all six sides of each unit treated using a nano-based hydrophobic impregnating sealer) M-01: The scope includes the supply of 35mm thick Cleft, limestone , with surface finishes such as Honed, Sandblasted, River Wash, or Brushed, as approved by the Architect/Client crafted through the process of cleaving or splitting the stone along its inherent layers. The rate shall encompass cutting the limestone to the required dimensions as per approved drawings, including allowances for wastage, and providing 3mm thick CNC-cut chamfered edges on all exposed sides. The scope further includes the application of an approved nano-based hydrophobic impregnating sealer for water repellency, which shall not alter the natural colour of the stone. The sealer is to be applied in two coats on the front face, rear & four edges, strictly in accordance with the manufacturer’s specifications. Prior to application, the limestone surface shall be cleaned using a brush or roller, wiped with a moist cloth, and thoroughly dried to ensure adequate surface preparation. The application shall be carried out uniformly to ensure effective protection against stains, discoloration, and efflorescence while preserving the natural appearance of the stone. The quoted rate shall be inclusive of all associated components, including the landed cost of stone at site, transportation, handling, unloading, cutting, wastage, edging, polishing, and sealing treatment for surface protection, as well as shaping the stone in accordance with the tender drawings. All works shall be executed under the supervision of the Engineer-in-Charge and strictly adhere to the approved methodology and relevant product data sheets. Sqm 140.00 0
BOQ Item shall be read in conjunction with Construction Performance Specifications Section 04 42 00-3/4 (2.2)
23.8 WT-06 : Fire Retardant FRP Cladded Canopy Cladding (2 Nos) @ Soffit, Facia & Top of Periphery of Canopy: (The scope includes the supply,fabrication & installation of the complete FRP system, comprising all necessary hardware, accessories, and support framework. (Note: Cost excludes the FRP material; installation only is covered.)
23.8.1 This scope covers the design, engineering, supply, fabrication, packaging, delivery, and installation of Fire Retardant FRP (Fibre Glass Reinforced Polymer) Cladding with approved pattern, design, and colour using aluminium toggles, an aluminium framework or runner system—comprising structural profiles and HDG brackets—shall be securely mounted onto the existing mild steel (M.S.) structure using SS 316 grade nuts, bolts, and washers. The brackets will be positioned along the flange line of the FRP cladding panels, precisely aligned with the intended installation level. The aluminium framework will be pre-configured to accommodate aluminium toggles, which shall be fixed using pan head screws. Holes will be drilled into the flanges of each FRP panel to facilitate toggle engagement. During installation, each FRP panel will be safely lifted and held in position between adjacent aluminium runners, with temporary supports provided as needed. Aluminium toggles will be inserted through the framework and passed through the flange holes of the panel. The subsequent panel will be positioned such that the projecting toggles from the previously installed panel engage with the flange holes of the new panel, ensuring interlocking continuity. The aluminium framework will then be extended and fixed along the edges of the newly placed panel, continuing this sequence across the entire span. Any surface damage incurred during transportation or lifting will be rectified using FRP finishing material, and open joints will be maintained as per design requirements. All elements will be aligned in accordance with approved shop drawings, ensuring compliance with specified tolerances. he site engineer will oversee the work and coordinate inspection with the client’s designated engineer. Additionally, a 1.2 mm thick EPDM membrane shall be placed beneath the FRP panels of the canopy, forming a seamless waterproofing layer that prevents water ingress and safeguards the integrity of the underlying structure. Sqm 2,100.00 0
BOQ Item shall be read in conjunction with Construction Performance Specifications Section 06 83 16 (3.3.1)
23.8.2 Fire Retardant Fibre Reinforced Polymer (FRP) composite panels : (Scope includes Supply and delivery of FRP Panels to site Cost Only) M-02: This scope of work includes the supply and installation of 5–6 mm thick Fibre Reinforced Polymer (FRP) composite panels, manufactured using a polymer matrix engineered with E-glass fibre reinforcement and a fire-retardant resin matrix. The panels shall incorporate advanced fire-retardant additives and UV stabilizers to ensure high structural integrity, long-term durability, and resistance to environmental degradation. Manufactured via the pultrusion process, the FRP panels shall exhibit consistent cross-sectional pigmentation—achieved by uniformly dispersing pigments within the resin prior to curing—thereby ensuring superior weatherability, colour retention, and enhanced fire and smoke suppression characteristics Sqm 2,100.00 0
BOQ Item shall be read in conjunction with Construction Performance Specifications Section 06 83 16 (2.1.2.2)
23.8.3 Following to be carried out at no extra cost: Performance Mockup- Fire Retardant FRP Cladded Canopy Cladding (Tested by NABL Accredidated Laboratory) MODULE TYPE -Performance Mockup should Size include 5 Nos. of FRP Panels (Length) X 3 Nos. of FRP Panels (Width) Testing standards: ASTM E 331-09, ASTM E 330-10, ASTM E 695/ EN 14019, AAMA 501.5 or ASTM C 1515 , ASTM C 1354,AAMA 501.4/AAMA 501.6 Testing Specifications:Wind Uplift Testing, Ultimate Wind Load Testing, Water penetration test by Static Air Pressure Difference,Thermal Cycling,Impact Resistance ,Anchor Pull – Out Test ,Panel Break Test ,Seismic & Dynamic Testing
BOQ Item shall be read in conjunction with Construction Performance Specifications Section 06 83 16 (3.7)
23.9 WT-07 : Aluminium Vertical Sleek Suspended Glazing System with Glass Face Sealed along with S.S. 316 Grade Stainless Steel cladded Mullions @ Themed Café. (Scope includes: supply of glazing system including all requisite hardware & accessories , fabrication and installation of the system and installation of glass (Glass cost excluded).
23.9.1 The scope of work includes the design, engineering, furnishing, fabrication, supply, delivery, packaging, protection, onsite water testing conducted in accordance with AAMA 501.2-25 along with installation of a complete Aluminium Vertical Sleek Suspended Glazing System at the Themed Cafe incorporating 37.52mm thick Sentry Laminated Insulated Glass Unit with Stainless steel 316 Grade cladded Mullions. The system is designed with a concealed fixing strategy that offsets the glass from the structural mullions to create a distinctive floating façade aesthetic, devoid of horizontal transoms. The installation ensures a seamless façade free from horizontal transoms Vertically, the glass is suspended from slim Aluminium mullions finished in Hyper Durable Powder Coating (RAL shade as directed by the architect). Each mullion is externally clad with precision-fabricated stainless-steel sheet covers, combining mechanical protection with elevated visual appeal. The system will be suspended from the top, with engineered tolerances at floor level to accommodate thermal expansion, seismic movements, and dynamic wind loads. Deadload brackets shall be provided at mullion locations to support the weight of the glass units. The glass units shall be held on their vertical sides using mechanical toggles, spaced as per structural design. Dead loads will be transferred through concealed brackets at the bottom, connected to the vertical Aluminium members. Glass-to-glass joints shall be sealed using non-staining silicone sealant from an approved equivalent, with vertical joints recessed by 3 mm to enhance visual aesthetics. Sqm 220.00 0
The system shall remain completely free of floor-level contact, with a U-channel provided at both top and bottom to interface with false ceilings and floor finishes. Adequate provision for minimum 20 mm vertical movement shall be integrated to accommodate RCC slab or as advised by the structural engineer. Glazing units are toggled into the mullions and sealed within precision-machined grooves, ensuring stability and weather-tight performance. Double-sided 3mm thick structural tape reinforces metal-to-frame adhesion, while the transom-free design showcases an advanced synergy of architectural minimalism and structural integrity. The system must comply with performance standards for air tightness, water tightness, and structural stability, with all deflections within permissible limits. Performance testing shall be carried out at a NABL-accredited laboratory to validate compliance with design parameters, including seismic movement criteria. The quoted rate shall include all design approvals, engineering, shop drawings, and coordination with the architect and consultant. It shall also include the strengthening of the Aluminium gridwork, and the provision of structural connections required to mount the client’s branding signage as advised by the client.
BOQ Item shall be read in conjunction with Construction Performance Specifications Section 08 44 26.16 (2.3 & 3.3) Section 07 21 00 ( 2.2) Section 07 92 00 Section 05 05 13 (2.2) Section 05 05 19.1 Section 07 13 00 Section 07 62 00 (2.2) Section 08 85 00
23.9.2 High-Performance Vision Glass : Extra over WT-07 (Scope includes Supply and delivery of High-Performance vision glass panels to site Cost Only) GL-01: 37.52mm Thick Single Laminated Insulated Glass Unit ( IGU) Consists Of 6mm Thick Extra Clear / Low Iron Heat Strengthened (HS) Outerlite + 1.52mm Thick Clear PVB Interlayer + 6mm thick Extra Clear / Low Iron Heat Strengthened (HS) Glass, such as Saint-Gobain SKN 183 or an approved equivalent, with the Low Emissivity ( Low-E) Performance coating applied on Surface # 4 + 16mm Thk 100 % Air Filled Gap with Black Spacer + 8mm Thick Extra Clear / Low Iron Fully Tempered (Heat Soak Test to reduce risk of spontaneous breakage) Innerlite Glass Unit . Base clear /coated glass shall be low iron (high- clarity) glass with iron content less than 120 parts per million (ppm), offering superior transparency and minimal colour distortion. Coated Glass shall be manufactured in accordance to EN 1096. Luminous & solar Characteristics are determined as per CIE015:2018/EN 410 standards. Thermal Transmittance is determined as per EN 673 standards. The IGU shall be factory-assembled by an approved glass processor and designed to ensure high optical clarity, durability, and thermal performance in accordance with relevant standards. Coated Glass are manufactured in accordance to EN 1096. Luminous & solar Characteristics are determined as per EN 410 standards. Thermal Transmittance is determined as per EN 673 standards. Rate shall be inclusive of Landing cost on site, Wastage , Breakage of the Glass and inclusive of packing cost. Sqm 220.00 0
BOQ Item shall be read in conjunction with Construction Performance Specifications Section 08 81 23 (1.3)
23.9.3 Following to be carried out at no extra cost: Performance Mockup- Aluminium Sleek Suspended Glazing System (Tested by NABL Accredidated Laboratory) MODULE TYPE - Performance Mockup should include 3 Nos. of modules X 8.4 Mtrs (Varies) height for Glazing. Testing standards: ASTM E 283-04, ASTM E 331-09, AAMA 501.1-105, ASTM E 330-10, AAMA 501.4-09, BS EN 14019, AS/NZS 4284.AAMA 501.4 Testing Specifications:Air Infiltartion Test/Water Penetration Test by Static Air Pressure Difference/ Water Penetration Test by Dynamic Air Pressure Difference/ Structural Performance Test by Static Air Pressure Difference/ Vertical Inter- Story Movement Test/Seismic & Wind – Induced Inter- Story Drift/ Structural Proof Load Test/Impact resistance Test/ seal Degradation Test.
BOQ Item shall be read in conjunction with Construction Performance Specifications Section 08 44 26.16( 3.8) Section 07 21 00 ( 2.2) Section 07 92 00 Section 05 05 13 (2.2) Section 05 05 19.1 Section 07 13 00 Section 07 62 00 (2.2) Section 08 85 00
23.9.4 Double Leaf Frameless Manual Swing Doors with Heavy Duty Floor Spring Integrated in Aluminium Vertical Sleek Glazing System :Door Opeining Size: 1550mm ( Width) x 2500mm ( Height) (Scope includes Glass Supply + System + Fabrication + Installation Cost) The scope includes the supply, fabrication, delivery, and installation of a double-leaf manual swing door system, comprising 12mm thick, fully toughened, heat soak-tested clear glass (non-performance) as per approved shop drawings.Each door leaf will be patch-fitted with high-quality SS 304 satin-finished hardware, including top and bottom patch fittings, and mounted on a concealed floor spring system. Floor springs shall offer EN 3–6 adjustable closing force, with hold-open (80°–165°), optional delayed closing, and integrated back-check features, tested as per EN 1154 standards.The system includes SS 304 satin-finished ‘H’-type pull handles (Ø 25mm × 600mm c/c), a bottom lock with cylinder and keeper plate, and a stainless steel floor-mounted half-moon door stopper (Ø 42mm × 25mm). Where required, overpanel and side panel patches shall be provided with matching satin finishes.All accessories and hardware shall conform to approved specifications, ensuring smooth operation, durability, and alignment. The quoted rate includes all components, fabrication, packaging, delivery, installation, and associated costs such as landing charges, breakage, and compliance with technical standards. Nos 2.00 0
BOQ Item shall be read in conjunction with Construction Performance Specifications Section 08 42 13 ( 2.3) Section 07 92 00 Section 05 05 13 (2.2) Section 08 85 00
23.10 WT-08A : High Height Glass Railing with S.S. 316 Grade Vertical Post/Balustrades & S.S.316 Grade U- Type Top Height of Glass Railing :2100mm/840mm
23.10.1 The scope of work includes the designing, engineering, fabrication, protection, packaging, delivery to site, installation, and final fixing in position of a high-height glass railing system. The system comprises Sentry Laminated Glass panels securely supported by Stainless Steel 316 Grade vertical balustrades, with a continuous Stainless Steel 316 Grade U-type top rail installed along the upper edge of the glass panels, providing both structural integrity and a sleek architectural finish. The railing is designed to resist a maximum wind pressure of 1.8 kPa in accordance with IS 875 (Part III), and to sustain a live load of 300 kg/m across all levels. The Sentry Laminated Glass is held in position by satin-finished SS 316 Grade vertical balustrades spaced at a maximum of 850 mm centre-to-centre, as indicated in the tender drawings. Articulated SS 316 Grade balustrade clamps or brackets provide secure multi-point fixing of the glass panels, ensuring both structural stability and a clean, minimalist aesthetic. Each balustrade is anchored to the RCC slab or MS structure using SS 316 Grade base plates, fixed with four SS 316 Grade anchor bolts per plate for robust attachment. Glass panels are mounted onto the SS balusters using articulated clamps, with appropriate EPDM gaskets, washers, and all necessary accessories. The system includes top-mounted SS 316 Grade rails, fastened securely with stainless steel screws, washers, and fasteners, along with Teflon or Nylon bushes to prevent bi-metallic contact. All works shall be executed strictly in line with approved drawings, project specifications, and engineer's instructions to ensure long-term performance, safety, and visual alignment with the architectural design intent. Rmt 115.00 0
BOQ Item shall be read in conjunction with Construction Performance Specifications Section 05 73 13 ( 2.1,C.2.2,2) Section 07 92 00 Section 05 05 13 (2.2) Section 05 05 19 Section 07 62 00 Section 08 85 00
23.10.2 Non-Performance Vision Glass- Railing : Extra over WT-08A (Scope includes Supply and delivery of Non-Performance vision glass panels to site Cost Only) GL-02:17.52 mm thick laminated glass panel shall comprise: [8 mm thick clear fully tempered glass (subjected to heat soak test)] + [1.52 mm thick clear SentryGlas interlayer] + [8 mm thick clear fully tempered glass (subjected to heat soak test)].The glass unit shall be fabricated by an approved processor to ensure structural integrity, safety, and visual clarity. Rate shall be inclusive of Landing cost on site, Wastage , Breakage of the Glass and inclusive of packing cost. Sqm 150.00 0
BOQ Item shall be read in conjunction with Construction Performance Specifications Section 08 81 23 (1.3)
23.10.3 Following to be carried out at no extra cost: Handrail/Balustrade Onsite Performance Tests: Extra over WT-08A (Tested by NABL Accredidated Laboratory) High Height Glass Railing with S.S. 316 Grade Vertical Post/Balustrades to be tested st site using a NABL accredited laboratory as per ASTM E 2353- 21 “Standard Test Methods for Performance of Glazing in Permanent Railing Systems, Guards, and Balustrades” Uniformly Distributed Load Applied to the Infill ( Infill load Test) as per ASTM E2353 CL 12.2.4 Horizontally Uniformly Distributed Line Load ( Uniform Load Test) as per ASTM E2353 CL 12.2.5 Point Load Applied to Part of the Infill (Concentrated Load test) as per ASTM E2353 CL 12.2.6 Shot Bag Impact test as per ASTM E 783
BOQ Item shall be read in conjunction with Construction Performance Specifications Section 05 73 13 (3.5) Section 07 92 00 Section 05 05 13 (2.2) Section 05 05 19 Section 07 62 00 Section 08 85 00
23.11 WT-08B : Stainless Steel 316 Grade Safety Railing.
23.11.1 The scope of work comprises the complete design, engineering, fabrication, supply, installation, inspection, and commissioning of the S.S. 316 grade safety railing system. The supply shall include all components of the railing system, such as S.S. 316 grade flat bars for vertical posts, S.S. base plates, anchor bolts, hardware, and all other necessary accessories. Fabrication works shall include cutting, welding, and assembly of railing sections strictly in accordance with the approved design drawings, Construction Performance Specificationss, and structural calculations. S.S. box-type covers shall be welded to S.S. 316 grade base plates, which shall be securely anchored to the RCC structure using S.S. 316 grade ETA-approved anchor fasteners, four (4) numbers per base plate, as indicated in the tender drawings. Vertical members shall consist of 8 mm thick S.S. 316 grade flat bars with satin or mirror finish, installed within the S.S. cover at intervals of 1500 mm center-to-center. A continuous 10 mm thick S.S. 316 grade flat bar shall be provided at the top to function as the handrail.The scope further includes surface finishing, quality control, and installation of the complete railing system. All materials, fabrication, and installation works shall comply with applicable standards and codes related to structural steel and corrosion resistance. Quality checks shall be carried out at every stage of the work to ensure dimensional accuracy, structural integrity, and overall performance of the railing system. Rmt 40.00 0
BOQ Item shall be read in conjunction with Construction Performance Specifications Section 05 73 13 ( 2.1,C.2.2,2.2.3) Section 07 92 00 Section 05 05 13 (2.2) Section 05 05 19 Section 07 62 00 Section 08 85 00
23.12 WT-09 : Pergola (Extruded Aluminium box Type Tubes - 50mm (width) × 100mm (depth) Duly coated with Hyper Durable Powder Coating @ Open Terrace- 2nd Floor Plan
23.12.1 The scope of works includes the design, engineer, furnish, fabricate, supply, package, deliver, protect, and install a complete pergola framing system comprising extruded Aluminium and Hot Dip Galvanized mild steel (M.S.) structural elements. The system shall consist of extruded Aluminium box tubes, 50mm (width) × 100mm (depth) × minimum 3mm (thickness) with final thickness of the Tube shall be in accordance with structural design calculations , manufactured from Aluminium Alloy Grade AA 6063-T6, uniformly spaced at 250mm center-to-center , Bi-metallic separators shall be provided wherever dissimilar materials interface. All Aluminium box tubes shall be pre-fixed onto continuous Aluminium L-angle runners to maintain precise alignment & ensure uniform load transfer. throughout the structure. The complete pergola assembly shall be securely anchored to hot-dip galvanized mild steel box tube supports, with bi-metallic separators provided at all interfaces between dissimilar materials to prevent galvanic corrosion. All fixings connecting Aluminium members to the steel structure shall be stainless steel grade SS 316 pan head self-drilling screws, selected to provide superior corrosion resistance and mechanical reliability. All Aluminium components, including the extruded box tubes and L-angle runners, shall be finished with a high performance hyper-durable powder coating with a dry film thickness of 60–80 microns, fully compliant with AAMA 2605 standards, ensuring long-term durability, UV stability, and resistance to environmental degradation Sqm 80.00 0
23.13 WT-10 : Glass Skylight ( Conventional Curtain Wall Glazing System Along with Aluminium Pressure Plate & cover Cap, both finished with Hyper Durable Powder Coating) @ Terrace. (Scope includes: supply of glazing system including all requisite hardware & accessories , fabrication and installation of the system and installation of glass (Glass cost excluded).
23.13.1 The scope includes the design, engineer, furnish, fabricate, supply, package, deliver, field test, protect, and install a complete Conventional Curtain Wall Glazing System, utilizing a mechanically anchored Aluminium pressure plate and cover cap system for the secure installation of glazing panels—including high-performance vision glass. Each high-performance glass panel shall be mechanically fixed to the structural framing using precision-engineered Aluminium pressure plates, which apply a controlled and uniform clamping force. This ensures accurate glass alignment and secure retention of the glazing units, thereby enhancing the structural integrity, weather resistance, and long-term performance of the façade. To achieve a refined architectural appearance, Aluminium cover caps shall be installed over the pressure plates to conceal all mechanical fasteners such as bolts and nuts. These caps shall be designed for seamless integration within the curtain wall system, providing visual continuity, a sleek, modern aesthetic, and additional environmental protection. The complete curtain wall system shall be designed to offer Mechanical reliability through robust structural anchoring, Superior air- and water-tightness, Long-term durability under varied environmental conditions, Ease of access for maintenance, and Architectural sophistication with a clean, uninterrupted visual expression. All system components shall be delivered to site in fully protected condition, thoroughly field-tested, and installed in strict compliance with approved shop drawings, manufacturer’s specifications, and under the supervision of the Engineer-in-Charge. Sqm 25.00 0
BOQ Item shall be read in conjunction with Construction Performance Specifications Section 08 63 00 ( 2.1-D,E & F, 2.2,3.4.6) Section 07 21 00 ( 2.2) Section 07 92 00 Section 05 05 13 (2.2) Section 05 05 19 Section 07 13 00 Section 07 62 00 (2.2) Section 08 85 00
23.13.2 Non-Performance Vision Glass- : Extra over WT-10 (Scope includes Supply and delivery of Non-Performance vision glass panels to site Cost Only) GL-03: 17.52 mm thick laminated glass panel shall comprise: [8 mm thick clear Heat strengthened Glass] with clear nano- technology based protective coating on surface #1 + [1.52 mm thick clear SentryGlas interlayer] + [8 mm thick clear Heat strengthened Glass]. The glass unit shall be fabricated by an approved processor to ensure structural integrity, safety, and visual clarity. Rate shall be inclusive of Landing cost on site, Wastage , Breakage of the Glass and inclusive of packing cost. Sqm 25.00 0
Laminated Safety Glass with Nano Protective Coating (Protective Glazing Surface Treatments) on exposed surface # 1 of Canopy Glass:The scope includes the supply and delivery of 17.52mm thick laminated safety glass, treated on surface #1 with a factory-applied, optically clear nano-technology-based protective coating, chemically bonded to the glass. This advanced coating may be applied manually using an air-operated spray gun or through an automated application system, and imparts durable hydrophobic and oleophobic properties, ensuring resistance to corrosion, etching, UV degradation, staining, cement splashes, and construction dust. It shall not interfere with visible light transmittance nor compromise the performance of low-emissivity coatings on surfaces 2 or 3.The coating shall be formulated to withstand post-construction cleaning and environmental exposure, preserving glass clarity and integrity in high-traffic and exposed canopy conditions. It must be fully compatible with silicone sealants, gaskets, clamping systems, and suction lifting devices, and must allow for re-application after its initial service life for extended protection.
BOQ Item shall be read in conjunction with Construction Performance Specifications Section 08 81 23 (1.3) Section 08 87 00
23.13.3 Following to be carried out at no extra cost: Performance Mockup- Glass Skylight (Tested by NABL Accredidated Laboratory) MODULE TYPE - Performance Mockup should include 3 Nos. of modules X 8.4 Mtrs (Varies) height for Glazing. Testing standards: ASTM E 283-04, ASTM E 331-09, AAMA 501.1-105, ASTM E 330-10, AAMA 501.4-09, BS EN 12600, AS/NZS 4284.AAMA 501.4 Testing Specifications:Air Infiltartion Test/Water Penetration Test by Static Air Pressure Difference/ Water Penetration Test by Dynamic Air Pressure Difference/ Structural Performance Test by Static Air Pressure Difference/Structural Proof Load Test/Impact resistance Test/ Seal Degradation Test.
BOQ Item shall be read in conjunction with Construction Performance Specifications Section 08 44 26.16( 3.10) Section 07 21 00 ( 2.2) Section 07 92 00 Section 05 05 13 (2.2) Section 05 05 19.1 Section 07 13 00 Section 07 62 00 (2.2) Section 08 85 00
23.14 WT-11 : Glass Canopy System : (Scope includes: supply of glazing system including all requisite hardware & accessories , fabrication and installation of the system and installation of glass. (Glass cost excluded).
23.14.1 This scope covers the design, engineering, supply, fabrication, delivery, and installation of a glass canopy system comprising Aluminium toggles, rafters, purlins, and HDG mild steel brackets. All components shall be securely mounted onto the existing M.S. structure using SS 316-grade fasteners to ensure corrosion-resistant and structurally robust connections. Aluminium rafters and purlins will be pre-configured for toggle integration, fixed using sex bolts and concealed fasteners, with bimetallic separators placed between dissimilar materials to prevent galvanic corrosion.The system is designed for clean external appearance, with insulated glass units housed in U-channels and factory-installed primary gaskets for weather sealing. EPDM gaskets serve as water barriers with full drainage provision. Inner air seals shall feature vulcanized moulded corners to ensure continuous airtight framing. In the event of water ingress, rafter and purlin profiles will function as concealed drainage channels. All installation work shall be carried out under the supervision of the site engineer and verified through inspections in coordination with the client’s representative, ensuring strict compliance with design specifications and quality standards. Sqm 70.00 0
BOQ Item shall be read in conjunction with Construction Performance Specifications Section 08 44 23 ( 2.1-D,E & F, 2.2) Section 07 21 00 ( 2.2) Section 07 84 53 Section 07 92 00 Section 05 05 13 (2.2) Section 05 05 19 Section 07 13 00 Section 07 62 00 (2.2) Section 08 85 00
23.14.2 Non-Performance Vision Glass-: Extra over WT-11 (Scope includes Supply and delivery of Non-Performance vision glass panels to site Cost Only) GL-04: 37.52 mm thick Non- Performance Single Laminated Insulated glass unit shall comprise: [8 mm thick clear heat-strengthened (HS) outer lite Glass ] with an optically clear nano-technology-based protective coating that is chemically bonded to the exposed glass surface # 1 + [16 mm thick 100% air-filled cavity with black spacer] + [6 mm thick clear heat-strengthened (HS) Glass ] + [1.52 mm thick Clear SentryGlas interlayer] + [6 mm thick clear heat-strengthened (HS) inner lite Glass].The IGU shall be factory-assembled by an approved glass processor and designed to ensure high optical clarity, durability, and thermal performance in accordance with relevant standards. Rate shall be inclusive of Landing cost on site, Wastage, Breakage of the Glass and inclusive of packing cost. Sqm 70.00 0
Laminated Safety Glass with Nano Protective Coating (Protective Glazing Surface Treatments) on exposed surface # 1 of Canopy Glass:The scope includes the supply and delivery of 21.52mm thick laminated safety glass, treated on surface #1 with a factory-applied, optically clear nano-technology-based protective coating, chemically bonded to the glass. This advanced coating may be applied manually using an air-operated spray gun or through an automated application system, and imparts durable hydrophobic and oleophobic properties, ensuring resistance to corrosion, etching, UV degradation, staining, cement splashes, and construction dust. It shall not interfere with visible light transmittance nor compromise the performance of low-emissivity coatings on surfaces 2 or 3.The coating shall be formulated to withstand post-construction cleaning and environmental exposure, preserving glass clarity and integrity in high-traffic and exposed canopy conditions. It must be fully compatible with silicone sealants, gaskets, clamping systems, and suction lifting devices, and must allow for re-application after its initial service life for extended protection.
BOQ Item shall be read in conjunction with Construction Performance Specifications Section 08 81 23 (1.3) Section 08 87 00
23.15 WT-12 : Wind Driven Rain Defense (Storm Resistant) Fixed Horizontal Double Bank ("A" Class/ 99% Rain Defense) High Performance Aluminium Louvers Finsihed with Hyper Durable Powder Coating
23.15.1 The scope of work includes the complete design, engineering, fabrication, delivery, cutting, hoisting, installation, and commissioning of Extruded Aluminium High-Performance Rain Defence / Storm-Resistant Fixed Louvers, engineered to meet stringent wind-driven rain and air performance criteria. The louvers are BSRIA-tested in accordance with EN 13030, maintaining a 99% rain defence effectiveness at a wind speed of 29.1 mph and a rainfall rate of 3 inches per hour. The louver blades shall be fabricated from 6063-T6 aluminium alloy with a minimum blade thickness of 1.52 mm, and the frames shall have a maximum thickness of 2 mm. All components shall be mechanically fastened using stainless steel or aluminium fasteners. Installation of the louvers, including sill flashing, shall be carried out as per the manufacturer’s recommended procedures to ensure optimal water tightness and system performance Sqm 20.00 0
BOQ Item shall be read in conjunction with Construction Performance Specifications Section 08 91 91 ( 2.2) Section 07 92 00 Section 05 05 13 (2.2) Section 05 05 19 Section 08 85 00
23.16 WT-13 : Pre- Coated Solid Aluminium Sheet Cladding System (Open Ventilated Rainscreen Façade with concealed Hook On Fixing System) Finished with 3- Layer PVDF coating: @ Admin office/Pre- Coated Solid Aluminium Sheet Cladding System (Closed Groove System) @Aluminium Sheet Coping at the Termination of Solid Aluminium Sheet Cladding.
23.16.1 The scope of work includes the complete design, engineering, fabrication, supply, delivery, protection, and installation of a high-performance Pre- coated Solid Aluminium sheet cladding system using 3.0 mm thick pre-coated Aluminium solid sheets. Panels are installed using a hook-on concealed fixing system, ensuring clean aesthetics with no visible fasteners. As part of the installation methodology, Stainless Steel 304 Grade U-Type brackets shall be anchored firmly to the R.C.C. slab using stainless steel brackets and approved anchor fasteners, ensuring long-term stability to form a durable support system for transferring structural loads from extruded aluminium channel profiles/Gutter profiles to the R.C.C. Structure. Extruded. Aluminium channel profiles / Gutter profile used for load transfer shall be mechanically fastened to the stainless Steel 304 grade U-Type brackets using SS 316 grade nuts and bolts with serrated washers to ensure long-term corrosion resistance and mechanical stability. The cladding assembly shall comprise continuous vertical extruded Aluminium channel profiles /Gutters incorporating precision-cut openings to accommodate horizontal Aluminium diverters/gutters, along with pre-fixed extruded Aluminium vertical L-angles to facilitate the hook-on mechanism.. Extruded Aluminium vertical angle profile shall be pre-fixed to the solid Aluminium panels using SS or Aluminium POP rivets, placed at 1000 mm intervals along both the length and width of the panels. These extruded Aluminium vertical angle profile shall be connected to extruded Aluminium continuous C-channel profiles/Gutter profiles through a hooking system, ensuring proper structural alignment and reliable support. Sqm 550.00 0
The Aluminium sheets shall be V-grooved using a BIT router with a 90-degree cutting angle to achieve accurate folding and tray formation. Once the fabrication is complete, the trays shall subsequently be hung onto the vertical Aluminium channel profiles/Gutter profiles using the pre-fitted extruded Aluminium L-angle profile, ensuring secure, accurate, and precise placement. A continuous ventilated cavity of not less than 65 mm shall be maintained behind the cladding to promote natural air circulation, moisture control, and improved thermal performance, in compliance with IS 4101 (Part 1) and relevant DIN standards for ventilated façade systems. Open joints of 15 mm shall be maintained between adjacent stone panels to accommodate thermal expansion and contraction due to temperature variations.
This provision allows free movement of the stone panels and prevents cracking or damage. No silicone sealants shall be used within the joints, thereby preserving both the visual uniformity and functional performance of the open-joint system. Rainwater impacting the façade shall drain naturally through the integrated profile channels, maintaining the performance of the rainscreen system. To prevent deformation due to self-weight, wind load, or other external forces, vertical and horizontal stiffeners shall be incorporated into the Aluminium framing system to provide intermediate support and minimize deflection. Teflon, nylon, or PVC separators shall be installed at all points of contact between dissimilar metals to prevent bi-metallic corrosion and ensure long-term durability. All extruded Aluminium components shall be manufactured from 6063-T6 alloy in accordance with ASTM B221M, and the entire cladding assembly shall be designed to withstand wind loads as per IS 875-Part 3 2015 .and comply with relevant international guidelines, including the structural requirements of AS 1288-2006. Extruded Aluminium vertical channels/gutters shall be finished with a super-durable powder coating with a thickness of 60–80 microns, complying with AAMA 2604 requirements and in colours approved by the Architect. All concealed Aluminium surfaces, including Aluminium vertical L-angle profile , shall be finished with a chrome-free pre-treatment primer coating.
All brackets, screws, bolts, nuts, and anchor fasteners shall be of SS 316 grade and installed strictly in accordance with the approved design drawings, construction documents, and structural calculations. All brackets, screws, bolts, nuts, and anchor fasteners used in the system shall be of SS 316 grade and shall be installed strictly in accordance with the approved design intent, construction drawings, and structural calculations. All tolerances shall be carefully maintained to prevent misalignment, undue stress, or deformation of the panels. All fabrication and installation activities shall strictly follow the approved shop drawings, design intent, and structural calculations, thereby guaranteeing structural integrity and performance. and designed in accordance with AS 1288-2006 standards.. All brackets, screws, bolts, nuts, and anchor fasteners used in the system shall be of SS 316 grade, installed strictly in accordance with the approved design intent, construction drawings, and structural calculations.
Pre- Coated Solid Aluminium Sheet Cladding (Closed Groove System) Finished with 3- Layer PVDF coating @ Aluminium sheet copings provided at the Termination of Solid Aluminium Sheet Cladding-Terrace Parapet Level :The scope of work includes the provision and installation of pre-coated solid Aluminium sheet cladding in an closed-groove system, finished with a three-layer PVDF coating to ensure superior durability and weather resistance. Aluminium sheet copings shall be installed at the termination of the solid Aluminium sheet cladding, specifically at the R.C.C. terrace parapet level. All Aluminium coping components shall be finished in a colour approved by the Architect or Client, with exposed surfaces receiving a high-performance three-layer PVDF coating with a total dry-film thickness of 30–35 microns, fully compliant with AAMA 2605 standards, ensuring long-term durability, UV stability, and colour retention. Each Aluminium panel shall be mechanically fixed to a precision-engineered Aluminium support framing system, which is in turn secured to hot-dip galvanized mild steel brackets using stainless steel nuts and bolts, all in accordance with the approved design intent and structural calculations. The mild steel brackets shall be anchored to the R.C.C. slab using Grade 316 stainless steel ETA-approved anchor fasteners, as per the approved design and structural specifications. Panels shall be fabricated with grooved and bent profiles, reinforced with corner cleats, and secured using Grade 316 stainless steel screws. Approved clips and rivets shall also be used to maintain precise alignment and overall stability while accommodating vertical and horizontal thermal expansion. The installation system shall feature accurately aligned vertical and horizontal joints to ensure structural integrity throughout the building’s life cycle.To enhance durability and provide long-term weather and water resistance, a dual-layer protection system shall be provided, consisting of A 1.2 mm thick galvanized iron (G.I.) primary flashing/seal, and 1.2 mm thick EPDM waterproofing membrane installed beneath the Aluminium panels. All Aluminium sheets shall be fabricated from 3xxx series Aluminium alloy, Temper H14 or H16, conforming to BS 1474 or an equivalent international standard. All panel joints shall be sealed with a high-performance, weather-grade silicone sealant, applied as a continuous bead along the full length of each joint to form a watertight barrier, effectively preventing water ingress and enhancing the durability, weather resistance, and longevity of the cladding system. The solid Aluminium panel cladding shall be provided in strict accordance with the requirements of the Contract Documents, as well as the Design Report and Tender Drawings.
Fixing Methodology of Pre- Coated Perforated Aluminium Sheet Cladding (Closed Groove System) @ Aluminium Sheet Copings at Termination of Solid Aluminium Sheet Cladding - Terrace Parapet level : The scope of work also includes the supply, fabrication, and installation of pre-coated solid aluminium sheet coping in closed groove system at the top of the pre- coated solid Aluminium sheet Cladding, specifically @ Terrace parapet level, finished with a three-layer PVDF coating (30–35 microns) compliant with AAMA 2605 for long-term durability, UV stability, and colour retention. All aluminium components shall be fabricated from 3xxx series aluminium alloy (Temper H14/H16) conforming to BS 1474, mechanically fixed to a precision-engineered aluminium support framework using Grade 316 stainless steel screws, approved clips, and rivets, with panels reinforced with corner cleats and grooved/bent profiles to accommodate thermal expansion. A dual -layer protection system comprising 1.2 mm G.I. flashing and 1.2 mm EPDM waterproofing membrane shall be provided beneath the panels, and all panel joints shall be sealed with high-performance weather-grade silicone to ensure watertightness, structural integrity, and long-term performance, in accordance with the Contract Documents, Design Report, and Tender Drawings. All panel joints shall be sealed with a high-performance, weather-grade silicone sealant, applied as a continuous bead along the full length of each joint to form a watertight barrier. This prevents water ingress and enhances the overall durability, weather resistance, and longevity of the cladding system. The solid Aluminium panel cladding shall be provided and installed in accordance with the requirements as specified in the Design calculations Report and Tender Drawings.
Application of EPDM Membrane (either self-adhesive or with Low-VOC bonding adhesive) on External Cavity R.C.C. Wall_ Behind Solid Aluminium Sheet Panel: The scope of work involves the provision and installation of a high-performance EPDM membrane, either self-adhesive or applied using a low-VOC bonding adhesive. This membrane is intended for use in weatherproof and watertight sealing applications on wall surfaces and must fully comply with EN 13984 standards. The selected membrane shall exhibit superior mechanical integrity, characterized by high flexibility and tear resistance, enabling it to accommodate thermal and structural movements within building assemblies. It must be resistant to ultraviolet radiation, capable of withstanding extreme temperature fluctuations, and impervious to chemical pollutants and moisture ingress. Installation may be executed using either self-adhesive application or bonding with adhesive, ensuring secure and durable placement. To guarantee long-term performance and reliability, the membrane shall meet the following technical criteria: a minimum tensile strength of 5 MPa and an elongation at break of at least 350%, as per EN 12311-2; a nail tear strength of no less than 70 N, tested in accordance with EN 13984; and a Shore A hardness rating of 50 or higher, verified according to ISO 7619. Additionally, the membrane must pass water tightness testing at 2 kPa, as specified in EN 1928. These performance benchmarks confirm the membrane’s suitability for creating resilient, airtight, and weatherproof seals in demanding construction environments.
Vertical Firestopping, Thermal & Acoustic Stone Mineral Wool Insulation System with Fluid Applied Air & Weather Barrier Coating over Stone Mineral Wool Insulation behind Solid Aluminium Sheet Panel Cladding @ R.C.C. Wall : The scope of work includes the supply and installation of a typical vertical firestopping, thermal, and acoustic insulation system located behind the stone cladding at dead wall areas, in accordance with the façade tender drawings. This system involves the installation of tested stone mineral wool insulation, with a minimum density of 120 kg/m³ and a minimum thickness of 50 mm, fixed directly onto the RCC wall using SS 316-grade stainless steel screws. The mineral wool slabs shall be securely held in place using specially designed fixing pins to ensure long-term stability and optimal performance. Over the insulation layer, a 100% silicone-based, vapour-permeable, fluid-applied air and weather barrier coating shall be applied to establish a continuous, protective envelope. This coating is engineered to resist air infiltration and water penetration while allowing water vapour to escape, thereby enhancing internal moisture management within the façade assembly. It must be UV-resistant and capable of withstanding prolonged exposure to sunlight, precipitation, and extreme temperatures without performance degradation. The manufacturer shall provide project-specific guidance, including the recommended dry film thickness, and must offer a warranty that ensures long-term performance and material compatibility when applied over mineral wool insulation. The complete system shall deliver high standards of fire resistance, thermal insulation, acoustic control, and weatherproofing, ensuring a durable and compliant façade solution.
BOQ Item shall be read in conjunction with Construction Performance Specifications Section 07 64 00 ( 2.2,2.4) Section 07 21 00 Section 07 92 00 Section 05 05 13 Section 05 05 19 Section 07 62 00 Section 08 85 00
23.16.2 Pre- Coated Solid Aluminium Sheet Cladding System, Finished with 3- Layer PVDF coating ( Closed Groove System) @ Main Entrance Portal The scope of work includes the supply, fabrication, and installation of a pre-coated solid Aluminium sheet cladded pergola, finished with a three-layer PVDF coating of minimum 35–40 microns, fully compliant with AAMA 2605 standards to ensure long-term durability, UV stability, and colour retention. The Aluminium sheets shall be mechanically fixed to a precision-engineered Aluminium framework, which will be mounted onto a hot-dip galvanized mild steel structure provided by others. The Aluminium framework shall be supported using hot-dip galvanized M.S. brackets, secured with Grade 316 stainless steel nuts and bolts, in strict accordance with the approved design intent and structural calculations. Each Aluminium panel shall be fabricated with grooved and bent profiles to ensure a secure attachment to the supporting framework. Corner cleats shall be provided at panel intersections to enhance structural stability. Panels shall be fastened using Grade 316 stainless steel screws, along with approved clips and rivets, to maintain precise alignment and ensure the overall stability of the cladding system. The installation shall incorporate defined vertical and horizontal grooves to accommodate thermal expansion, allowing the system to adjust to temperature variations without compromising structural integrity or aesthetic appearance. The complete system shall be installed in strict compliance with the approved design drawings, structural calculations, and relevant international standards. The installation shall ensure proper alignment, structural stability, aesthetic consistency, and long-term performance throughout the life of the cladding. Sqm 170.00 0
BOQ Item shall be read in conjunction with Construction Performance Specifications Section 07 64 00 ( 2.3) Section 07 21 00 Section 07 92 00 Section 05 05 13 Section 05 05 19 Section 07 62 00 Section 08 85 00
23.16.3 Pre- Coated Solid Aluminium Sheet : Extra over WT-13 (Scope includes Material Supply & Delivery at site Cost Only) M-01: 3mm Thk Pre- Coated Plain ( Flat ) Solid Aluminium Sheet Cladding Duly Coated with 3- Layer PVDF coating. Sqm 720.00 0
BOQ Item shall be read in conjunction with Construction Performance Specifications Section 07 64 00 ( 2.5)
23.16.4 M.S. Supporting Structure for Entrance portal Designing,Engineering,Cutting,Hoisting,Fabricating and Installing mild steel framing members in built up tubular (rectangular hollow tubes etc)for locations indicated in the tender drawings. The framing members are welded and anchored to the MS structure as indicated in the tender drawings. All concealed Mild steel sections shall comply to IS 2062 Grade A and Hot Dip Galvanised to minimum 100 microns coating.After welding the hot-dip galvanized sheet, touch-up of the welded or cut areas, if required, shall be carried out using zinc-rich paint to restore corrosion protection. The zinc-rich paint shall be applied on a clean, dry surface using either a brush or spray method. The paint must contain at least 65% to 69% metallic zinc by weight, or alternatively, more than 92% metallic zinc in the dry film, to ensure adequate corrosion resistance and maintain continuity of protection equivalent to the original galvanized coating. Rmt 10,000.00 0
23.16.5 Double Leaf Aluminium Framed Manual Swing Doors @ Admin office entry with Heavy Duty Floor Spring Integrated on wall : Door Opeining Size: 1800mm ( Width) x 3000mm ( Height) (Scope includes Glass Supply + System + Fabrication + Installation Cost) The scope includes the supply, fabrication, assembly, and installation of a Double Leaf Aluminium Door system constructed from 6063-T6 aluminium sections, finished with Hyper Durable Powder coating of minimum 50-90 microns compliant with AAMA 2605 standards.The door features 50 mm deep outer and vent frames with mitre-jointed corners, assembled using crimped, nailed, or screw-type cleats reinforced with metal adhesive. The vent frame overlaps the outer frame by 5 mm on three sides and is flush-fitted.Hardware includes all necessary gaskets, a 32 mm diameter satin stainless steel (Grade 316) offset pull handle, and a suitable locking mechanism supporting single or multi-point locking without visible profile changes.A heavy-duty floor spring system with adjustable EN 3 to EN 6 closing force, hydraulic hold-open (80°–165°), optional delayed closing, and back-check functions (EN 1154 tested) is provided, suitable for doors up to 1400 mm wide and 300 kg.All primary fixings use SS 316 star-head screws, with an M.S. insert plate supplied for the top pivot. The door includes a 24 mm thick fully toughened and heat-soak tested clear Insulated Glass Unit (IGU).The quoted rate covers complete supply, fabrication, delivery, installation, and all associated costs including hardware, packing, wastage, and compliance with technical specifications. Nos 1.00 0
BOQ Item shall be read in conjunction with Construction Performance Specifications Section 08 42 13 ( 2.3) Section 07 92 00 Section 05 05 13 (2.2) Section 08 85 00
23.16.6 High-Performance Vision Glass : Extra over door (Scope includes Supply and delivery of High-Performance vision glass panels to site Cost Only) GL-01: 37.52mm Thick Single Laminated Insulated Glass Unit ( IGU) Consists Of 6mm Thick Extra Clear / Low Iron Heat Strengthened (HS) Outerlite + 1.52mm Thick Clear PVB Interlayer + 6mm thick Extra Clear / Low Iron Heat Strengthened (HS) Glass, such as Saint-Gobain SKN 183 or an approved equivalent, with the Low Emissivity ( Low-E) Performance coating applied on Surface # 4 + 16mm Thk 100 % Air Filled Gap with Black Spacer + 8mm Thick Extra Clear / Low Iron Fully Tempered (Heat Soak Test to reduce risk of spontaneous breakage) Innerlite Glass Unit . Base clear /coated glass shall be low iron (high- clarity) glass with iron content less than 120 parts per million (ppm), offering superior transparency and minimal colour distortion. Coated Glass shall be manufactured in accordance to EN 1096. Luminous & solar Characteristics are determined as per CIE015:2018/EN 410 standards. Thermal Transmittance is determined as per EN 673 standards. The IGU shall be factory-assembled by an approved glass processor and designed to ensure high optical clarity, durability, and thermal performance in accordance with relevant standards. Coated Glass are manufactured in accordance to EN 1096. Luminous & solar Characteristics are determined as per EN 410 standards. Thermal Transmittance is determined as per EN 673 standards. Rate shall be inclusive of Landing cost on site, Wastage , Breakage of the Glass and inclusive of packing cost. Sqm 6.00 0
BOQ Item shall be read in conjunction with Construction Performance Specifications Section 08 81 23 (1.3)
TOTAL OF FAÇADE WORK 0
24 ACOUSTICS & AV WORKS
Acoustic Execution General Points: 1. Quantities are tentative; site measurement by execution team are essential prior to procurement. 2. The frame work in partition to have verticals as required and as per Manufacturers specs. 600 mm interval And horizontals at every 600 mm c/c or as per the Pattern of grooves whichever is less . Cost of partions to include insertion of necessary wooden members (with anti termite treatment) at skirting level or elsewhere as deemed fit by contractor. 3. At all services outlets such as switch sockets, data outlets,AC grills, etc. Horizontal member of adequate size and section to be provided. 4. All exposed wooden surfaces in this Item or anywhere else in the BOQ to have melamine polish as per approved sample. 5. All wooden/MDF framework under this item or anywhere else in the BOQ to be treated with anti termite treatment. 6. All the wooden framework under this Item or anywhere else in the BOQ will have well seasoned wooden members of species as defined in the individual item. 7. All Glass to Glass, Glass to wood and Glass to SS joints shall be sealed with Dow Corning Glass sealant with minimum contact surface to be not less than 6mm after cleaning and masking procedure with full tool & tackle .Silicon works to be got done by an approved specialized Agency.
8. The rate to be inclusive of additional frame work for white boards, panaboards, over head storages, counter fixing, display mounting wherever required 9. Angle beads have to be used at the external angles to get straight line and finish and protection from impacts. 10. Edge beads have to be used to protect the exposed edges of Gypboard. The edges can be at the opening for doors, windows, glazing, etc or any other exposed edges. 11. All wood and veneer to be seasoned and melamine polished to shade as / architects approval 12. All stainless steel cladding work to be provided and fixed by Architect approved specialist 13. All hardwood to be seasoned with anti-termite and. Rate are included for anittermite. 14. All openings for the cutouts for ducting/raceways/cables etc. in the partitions to be closed & made air tight. 15. Back ply / MDF board of required thickness 6mm, 8 mm, 12 mm is included in storages / DB shutters / repro /other counters/ fabric panelling/glass panelling/ system partition included in respective items.
24.A A. ACOUSTIC WORKS
Supply and installation of the following items :
24.A.1 FLOORING/STEP DETAILS: AUDITORIUM AND CONTROL ROOM 1. 10mm thick underlay Impact Isolation sheet (Getzner GREI, UPGREI OR Impactodan 10 OR MYK Laticrete) 2. Waterproofing membrane 3. Minimum 50mm Cement screed 4. 20mm Final Finish stone OR Tile 5. 12mm aluminium profile channel with LED light strip – of chosen color & intensity. Safety strip / Edge Profile Note: 1. Edge floor lighting strip concealed type for steps 2. The accessories of fixing, gluing of items shall be considered within the installation process costs. Sampling or mockup of the composition prior to execution shall be provided for approval of relevant authority. Final finish shades or material moodboard shall be made available prior to finalisation. sqm 255.48 0
24.A.2 CEILING DETAILS : SEAMLESS PERFORATED GLASS REINFORCED GYPSUM 1. 12.5mm thk Glass reinforced Gypsum perforated Acoustic Boards of approx. (1200 X 2500) OR (1200 X 600) sizes. Perforations of 8mm @ 18mm c-c recommended : Knauf Danoline Solopanel Q8/18 square 8x8mm perforations at 18mm c-c 2. GI framework to hold treatment composition. Framework. Saint Gobain Gypserra or similar standard 3. Isolation mount with Sylomer or similar PU based decoupler element. The bottom mount for suspending ceiling below shall have buffer piece between screws. Suspension member shall be aluminium or threaded rod of standard gauge. (Getzner Akustik 1+ Sylomer 30/ GERB or similar ) 4. Melamine foam 50mm approx. 32-40 kg/cu.m density OR FR PU foam (Bassotect G OR Astroforme or similar) 5. 15mm Elastomeric foam applied to the main ceiling slab. Density 180-240 kg/cu.m. FR rated (Kflex Kfonik OR Aramcell RD 230) 6. For Final Finish: Stable substrate, creating a seamless and acoustically monolithic finish on surface. System panel is made of randomly-spun mineral wool with factory-applied and sanded coating of recycled glass granulate, made of 82% natural and recycled materials This system is applied to a stable substrate and finished with post-consumer marble finishes. Standard and custom finishes are available to match any aesthetic or texture, and is available in any custom color. The accessories of fixing, gluing of items shall be considered within the installation process costs. Sampling or mockup of the composition prior to execution shall be provided for approval of relevant authority. Final finish shades or material moodboard shall be made available prior to finalisation. Note: HVAC duct and attenuator details, internal and external insulation types to be clarified with MEP team. sqm 192.31 0
24.A.3 AUDITORIUM WALLS AUDITORIUM WALLS ( SIDES & REAR) CONTROL ROOM : REARWALL AND CEILING: Description of Composition : 1. 15mm Moisture Resistant Fibre board. Channeled woodworks panels with 5mm grooves Surface finish : Portland maple ( 10077 – Lv1012- G5 – Knauf Armstrong) 2. Aluminium framework 50mm X 50mm 3. Infill Material - Varies in Auditorium : Refer sheet A0-05 In Control room : Infill A 4. Non bituminous synthetic membrane Mass loaded Vinyl Membrane. 2.5mm thk, Density >1600kg/cu.m . Weight approx. 5kg/cu.m. Applied to the surface with synthetic adhesive. INFILL A Rockwool core in slab format wrapped in black glass fabric Thickness minimum 50mm, Material density of 48kg/cu.m. INFILL B Fire rated PU Foam OR Melamine resin foam Thickness of minimum 25mm Material Density of 32-50 kg/m3 Color = Black or Dark Grey The placement of infills mentioned in Tender Drawing set sqm 342.81 0
24.A.4 STAGE WALLS 1.50mm thickness of aluminium gridwork / framing. 2.Within the framing : in order of stage towards backing wall: 2a. Infill of 50mm thickness 48 kg/ cu.m rockwool core wrapped in black glass fabric 2b. Air Gap of 50mmm 3.Above composition to be closed with: 3a. perforated MR/BWR grade ply with 3b. Final finish of 10mm PET FR grade boards sqm 92.90 0
24.A.5 STAGE CEILING - ACOUSTIC SPRAY Cellulose spray 40mm thick / FR rated 80% recycled Cellulose fibre (black) and its proprietary adhesive as per manufacturer method statement, sprayed directly to the substrate with a adequate priming if required. Having NRC of 0.9. Make : Envirospray 300, BuildX visible spray, Acospray D3 Fire Testing as per ASTM E84-11a, BS 476. Part 7 - Class 1 Fire Testing to EN 13501-1:2002 Fire Testing to AS1530.3 Fire Testing to BS 476 Pt 7 Fire Testing to AS 5637 sqm 62.71 0
24.A.6 STAGE FLOOR + STAGE FILL
24.A.6.1 Stage 1. 10mm thick underlay Impact Isolation sheet (Getzner GREI, UPGREI OR Impactodan 10 OR MYK Laticrete) 2. Expanded Polystyrene Blocks / XPS filling within stage raised volume ( Geotech foam, Modi-foam or Similar) 3. Autoclaved Aerated Concrete Blocks along perimeter of stage to the specified height. 4. Waterproof membrane 5. Minimum 50mm Cement screed 6. 20mm Final finish tiling 7. Electrical & AV provisioning. Casing made in same material as the front facia(item 9) of the stage ( i.e Russian Baltic birch or vineer with melamine polish) 8. Floor application : 10mm Carpet tiles creating non-reflective dark coloured surface ( to avoid screen image reflections). Color ideally to be dark grey or black. sqm 63.55 0
24.A.6.2 Stage Front Facia : Aluminium framework with coverered with 12mm plywood. Final finish 4mm Russian Baltic Birch OR veneer with water based melamine polish. Coating of Rhenocoll OR Similar for longevity. sqm 4.92 0
24.A.6.3 Stage Proscenium: Aluminium framework with coverered with 12mm plywood on both side of the framework. Final finish 4mm Russian Baltic Birch OR veneer with water based melamine polish. Coating of Rhenocoll OR Similar for longevity. sqm 25.55 0
24.A.7 WINGS Size: 1.5m X 3.8m (4no.s) STAGE WINGS / DOOR 1. TOWARDS GREEN ROOM : MR plain plyboard 12mm OR Birch ply with specific melamine polish applied onto surface. Easy to clean surface and can be laminated as per architects directions 2. Aluminium framework 50 X 50mm + (Infill B) Fire rated PU Foam within the framework 3.TOWARDS STAGE : Perforated MR Ply 12mm thick. Perforations of 8mm @ 60mm c-c 4.TOWARDS STAGE : PET Board 10mm applied on top of layer sqm 22.67 0
24.A.8 VISION PANEL Size: 2.1m X 0.9m CONTROL ROOM : VISION PANEL DETAILS (OPENABLE TYPE) 1. 2.layers of Gyproc Habito Board 12.5mm thick 2. Mass loaded Vinyl 3.5mm 3. Birch Plywood or Marine grade plywood with veneer melamine polished 4. Silicone Sealant at glass contact point with the ply/timber beading 5. Glazing panel at an angle of approx. 8-12 degrees as shown 6. Perforated aluminium or ply finish 7. Silica desiccant filling in packet format. Provision for future replacement to be ensured 8. Birch plywood OR marine grade plywood Note : All screws to be applied with silica gel while fastening for a complete seal through material boards. Decoupling Joint between the frame to achieve maximum transmission isolation to be ensured. FOR OPENABLE VISION PANEL : Recommended make >> Aluminium type with Laminated Glazed panel. Tostem Grants frame and installation. sqm 1.95 0
24.A.9 AUDITORIUM DOORS Size: 1.8m X 2.4m 1. 2.5 mm thk TEXSA tecsound T50 2. 9 mm thk BWP plywood 3. Final finish as per internal material - 9-20 mm thk as per fixture detail 4. Perimeter seal SCHALL PS 1010 p along hinge end and top end of door frame 5. Tectus concealed hinge TE 6453d wt. Up to 300 kg or similar 6. 25x50 mm thk framework seasoned teakwood or Salwood as per architect's instruction 7. Outer finish on BWP plywood or birch ply with melamine polish as per architect's instruction thickness as per finish 8. All handles, Hinges and hardware to be considered in the Final Cost. Access control or special hardware if any shall be consider seperate Recommended Make: Soundworks, Acoustical Surfaces India Nos 2.00 0
24.A.10 AUDITORIUM DOORS Size: 1.5m X 2.4m 1. 2.5 mm thk TEXSA tecsound T50 2. 9 mm thk BWP plywood 3. Final finish as per internal material - 9-20 mm thk as per fixture detail 4. Perimeter seal SCHALL PS 1010 p along hinge end and top end of door frame 5. Tectus concealed hinge TE 6453d wt. Up to 300 kg or similar 6. 25x50 mm thk framework seasoned teakwood or Salwood as per architect's instruction 7. Outer finish on BWP plywood or birch ply with melamine polish as per architect's instruction thickness as per finish 8. All handles, Hinges and hardware to be considered in the Final Cost. Access control or special hardware if any shall be consider seperate. Recommended Make: Soundworks, Acoustical Surfaces India Nos 1.00 0
24.A.11 CONTROL ROOM DOOR 1. 2.5 mm thk TEXSA tecsound T50 2. 9 mm thk BWP plywood 3. Final finish as per internal material - 9-20 mm thk as per fixture detail 4. Perimeter seal SCHALL PS 1010 p along hinge end and top end of door frame 5. Tectus concealed hinge TE 6453d wt. Up to 300 kg or similar 6. 25x50 mm thk framework seasoned teakwood or Salwood as per architect's instruction 7. Outer finish on BWP plywood or birch ply with melamine polish as per architect's instruction thickness as per finish 8. All handles, Hinges and hardware to be considered in the Final Cost. Access control or special hardware if any shall be consider seperate. Recommended Make: Soundworks, Acoustical Surfaces India Nos 1.00 0
24.B B. AUDIO - VIDEO WORKS
AV integration General points: 1.The installation of the audio rack with proper internal wiring, professional-grade termination, and structured cable management to ensure reliability and serviceability. 2.Complete system programming, configuration, and integration of all audio equipment shall be carried out to achieve seamless operation. 3.The installed system shall undergo thorough testing, calibration, and fine-tuning to standards to ensure optimal audio performance as per design intent. 4.On-site user training shall be provided, including system operation and basic troubleshooting, followed by formal handover. 5.Speaker output cabling shall be included in the scope unless explicitly covered by the electrical contractor. 4sqmm multicore twisted pair cable to be used for speaker output wiring. 6.Speaker mounting and associated hardware shall be considered separately if not within the scope of the appointed site contractor. All needed safety to be considered. 7.All cable lengths shall be finalized based on actual site conditions and as-built measurements. 8.Any deviations from the specified design or BOQ shall be clearly highlighted and brought to the consultant/client’s notice for approval prior to execution. Deviation to be highlighted. 9.Equipment or services of higher specification or performance than those mentioned in the BOQ are acceptable, subject to prior technical approval. 10.Safe storage of all equipment during the installation phase shall be ensured, with prior arrangement and responsibility clearly defined. 11.Before turning on the electronics, a proper check of incoming electrical reading is responsibility of AV system integrator. Any damage to the equipment will be solely responsibility of the system integrator.
24.B.1 VIDEO COMPONENT
24.B.1.1 SITC of DLED wall with 2.5mm pixel pitch for indoor applications. Size: 5.12mtr X 2.88mtr with 700nits Brightness Approved Makes: Absen/Christie/Barco Nos 1.00 0
24.B.1.2 Mounting Structure for DLED wall Nos 1.00 0
24.B.1.3 SITC of 55 inch 4K/UHD Professional Display / Resolution 3840 x 2160 p / HDCP: HDCP 2.2 / Brightness 300 nits / Contrast Ratio 4000:1 / Input Interface ( VIDEO: HDMI 2.0 (2); AUDIO: Stereo Mini Jack, USB: USB 2.0 (1) / Output Interface Audio: Stereo Mini Jack / External Automation Control Interface (RS232C, RJ45) Approved Makes: Samsung/LG/Sony Nos 3.00 0
24.B.1.4 SITC of Custom Wall Mounting Stand to hold 55 inch Display Approved Makes: Play AV/Lumi/Btech Nos 1.00 0
24.B.2 VIDEO INTERFACE
24.B.2.1 Supply, installation, testing and commissioning of Digital Podium with High density board and stainless steel, Equipped with 21.5” Touch Screen Monitor with Full HD resolution, HDMI, DisplayPort and VGA inputs,10-Point capacitive touch, Motorized monitor tilt adjustment function, with Top Sliding Cover to protect the display and to place laptop for presentation,Inbuilt Laptop Interface Modules Power x1 / USB x 2 / AUDIO x1 / SOUND IN x1 / HDMI x1 / RJ45 x1, Built in Gooseneck microphone with ON/OFF switch, Rack space to keep AV equipments, Castor Soft wheels for moving podium. Approved Makes: UNI / EIS / AHA/Peoplelink Nos 1.00 0
24.B.2.2 Supply, installation, testing and commissioning of 2x2 4K60 USB–C/HDMI Wall–plate Switcher Transmitter with one USB−C and one HDMI/USB inputs and independently routable HDMI and extended−range HDBaseT 3.0 outputs, that extends 4K60Hz (4:4:4) HDMI, USB 2.0, Ethernet, RS−232, IR and power signals over twisted pair cable to a remote compatible receiver. The local and remote connected USB peripherals, such as a room camera and microphone, are switchable for use of the switcher active USB host, for convenient hybrid meeting operation with both room and online participants.HDCP 2.3 compliant, supporting deep color, x.v.Color™, CEC, HDMI uncompressed audio channels, Dolby TrueHD, DTS–HD, 2K, 4K, and 3D as specified in HDMI 2.0, n active USB 3.2 host is connected to the switcher transmitter on either the transmitter or receiver sides. USB 2.0 signals are extended between the switcher transmitter and receiver sides, enabling connection and switching of the active USB host to both local USB 3.1 and remote USB 2.0 devices, such as camera and audio devices, or HID (Human Interface Devices) mouse or keyboard devices. Approved Makes: Lightware / Kramer /Extron Nos 1.00 0
24.B.2.3 Supply, installation, testing and commissioning of HDBaseT 3.0 receiver for 4K60Hz (4:4:4) HDMI, USB, Ethernet, RS−232, and IR signals over twisted pair, flexibly set as transmitter−side or receiver−side device. receiver−side receives the HDBaseT 3.0 signal and converts it back into the original input signals. It extends video signals to up 100m (330ft) over CAT copper cables at up to 4K@60Hz (4:4:4) video resolution.HDCP 2.3, EDID and CEC signals are passed through from the source to the display. Supports HDR10, deep color, x.v.Color™, lip sync, HDMI uncompressed audio channels, Dolby TrueHD, DTS–HD, 2K, 4K, and 3D as specified in HDMI 2.0.An active USB host is connected to the extender at either the transmitter or receiver sides. USB 2.0 signals are extended between the extender transmitter and receiver sides, enabling connection of the active USB host to both local and remote USB devices, such as camera and audio devices, or HID (Human Interface Devices) mouse or keyboard devices. Approved Makes: Lightware / Kramer /Extron Nos 1.00 0
24.B.2.4 Supply Install Testing & Commissioning of 4x4 4K60 4:4:4 HDMI+Audio Scaler Based Matrix/Switcher, video scaling processor provides a seamless and fast switching between inputs, with smooth and safe transition between presented content on displays, for convenient presentation experience of end–users.. Each HDMI output supports down or up scaling to account for any sink / source capability difference. The integrated audio matrix, with four analog audio input and four analog audio output ports support routing of any digital or analog audio source to sink including ARC (Audio Return Channel) sources.HDCP 2.3 compliant, supporting deep color, ARC, up to 7.1 uncompressed audio channels, and 3D, as specified in HDMI 2.0b.Each HDMI output can display content from two inputs in several layouts including picture–in–picture and side–by–side Approved Makes: Lightware / Kramer /Extron Nos 1.00 0
24.B.2.5 Supply Install Testing & Commissioning of HDBT receiver for HDMI, Ethernet, power, control and USB. Receiver should support 4K/UHD @60Hz with 4:2:0. Device should support RS232/IR/IP passthrough for display control. USB interface over HDBT for 100 meters. Certification : CE, RoHS, FCC Approved Makes: Lightware / Kramer /Extron Nos 2.00 0
24.B.2.6 Supply Install Testing & Commissioning of a high−performance, extended−reach HDBaseT transmitter for 4K HDR HDMI, RS−232 and IR signals over twisted pair. TP−583Txr converts all input signals into the transmitted HDBaseT signal. It enables extending video signal up to 100m (330ft) at 4K@60Hz (4:4:4) video resolution, up to 180m (590ft) at 4K@30Hz (4:4:4), and up to 200m (650ft) at HD video resolution over Kramer copper cables. It is compatible with standard HDBaseT−compliant extenders at 4K@30Hz and HD video resolutions. HDR HDCP 2.2 compliant. Supports deep color, x.v.Color™, lip sync, HDMI uncompressed audio channels, Dolby TrueHD, DTS–HD, 2K, 4K, and 3D as specified in HDMI 2.0. EDID and CEC signals are passed through from the source to the display Approved Makes: Lightware / Kramer /Extron Nos 5.00 0
24.B.2.7 Supply Install Testing & Commissioning of a high−performance, extended−reach HDBaseT receiver for 4K HDR HDMI, RS−232 and IR signals over twisted pair. TP−583Rxr converts the HDBaseT signal and outputs it to its HDMI and control ports. It enables extending video signal up to 100m (330ft) at 4K@60Hz (4:4:4) video resolution, up to 180m (590ft) at 4K@30Hz (4:4:4), and up to 200m (650ft) at HD video resolution over Kramer copper cables. It is compatible with standard HDBaseT−compliant extenders at 4K@30Hz and HD video resolutions. Approved Makes: Lightware / Atlona /Extron Nos 1.00 0
24.B.2.8 Supply Install Testing & Commissioning of Compact & Secure 4K Wireless Presentation Device,Supports Windows™ and Mac™ laptops, Chromebooks™, iOS™ and Android™ mobile operating systems. Four participants can present simultaneously. Supports up to 4K resolution. A simple and intuitive user interface enables iOS, Android, Chromebook, PC, and Mac device users to instantly connect to a main display without a dongle. 2.4GHz/5GHz Wi–Fi and MIMO antennas establish and maintain a fast and reliable connection. Approved Makes: Lightware / Kramer /Extron Nos 1.00 0
24.B.3 AUDIO COMPONENT
24.B.3.1 Supply, installation, testing and commissioning of Left Centre Right Speakers with their brackets having Frequency Response 50Hz to 20kHz Power Rating 800W AES, 3200W Peak Sensitivity 100dB @ 1W/1m Maximum SPL 129dB continuous, 135dB peak @ 1m Nominal Impedance 4 Ω Recommended Amplifier 500W to 1000W @ 4Ω Low Frequency Driver 2 x 12″ (300 mm) weather resistant long excursion woofer High Frequency Driver 1.75″ (44 mm) voice coil compression driver Crossover 1.2kHz Passive Finish Black impact resistant structured coating Connector Push type binding post, cable upto 4 mm diameter Enclosure 18 mm MDF direct radiator vented enclosure Horn 90˚ horizontal x 40˚ vertical Approved Makes: NEXO / L ACOUSTICS / PULZ Nos 3.00 0
24.B.3.2 Supply Install Testing & Commissioning of Surround Speakers with Atmos -includes brackets Frequency Response 65Hz to 18kHz Power Rating 250W AES, 750W peak Sensitivity 94dB @ 1W/1m Maximum SPL 117dB continuous, 123dB peak @ 1m Nominal Impedance 8Ω Transducers 8″ (200 mm) dual cone full range driver Dispersion 90° conical Finish Black impact resistant structured coating Connector Push type binding post, cable upto 4 mm diameter Enclosure 15 mm MDF direct radiator vented enclosure Grill Acoustically transparent black woven fabric Approved Makes: NEXO / L ACOUSTICS / PULZ Nos 16.00 0
24.B.3.3 Supply, installation, testing and commissioning of stage monitor speaker to be placed on the stage that should have frequency Response - 65Hz to 20kHz, Power Rating - 500W AES, 2000W peak, Sensitivity - 98dB @ 1W/1m, Maximum SPL - 125dB continuous, 131dB peak @1m, Nominal Impedance - 8Ω, Low Frequency Driver - 15″ (380 mm) Low-Mid driver with coaxial entry, High Frequency Driver - 1.75″ (44 mm) voice coil compression driver mounted coaxially, recommended Filter capable of 45Hz 18dB/octave Butterworth high pass filter; 20kHz 12dB/octave Butterworth low pass filter, Crossover - 1.3kHz Passive network, dispersion angle of 90° conical. To be supplied along with the needed mounting brackets. Necessary toeing and angling should be possible. Approved Makes: NEXO / L ACOUSTICS / PULZ Nos 3.00 0
24.B.3.4 Supply, installation, testing and commissioning of speaker with wall mount for green room and operators room monitoring that should have Frequency Response 65Hz to 20kHz Power Rating 150W AES, 600W peak Sensitivity 96.7dB @ 1W/1m Maximum SPL 118dB continuous, 124dB peak @ 1m Nominal Impedance 8Ω Low Frequency Driver 10″ (250 mm) Low-Mid driver with coaxial entry High Frequency Driver 1″ (25 mm) voice coil compression driver mounted coaxially Crossover 2.5kHz Passive, low loss air core inductors and MKP capacitors Dispersion 90° conical Approved Makes: NEXO / L ACOUSTICS / PULZ Nos 3.00 0
24.B.3.5 Supply Install Testing & Commissioning of HIGH POWER SUBWOOFER SPEAKERS: THE SPEAKER SHOULD PROVIDE A MINIMUM POWER OF 2000 WATTS CONTINUOUS POWER AND ALL SUBS TOGETHER SHOULD BE CAPABLE OF DELIVERING A SPL OF 115dB CONTINUOUS PINK NOISE AT A DISTANCE OF 80FT WITH A FREQUENCY RESPONSE OF 35HZ TO 200KHZ AND HAVE SENSITIVITY OF 101 dB 1w1m; THE DRIVER SHOULD BE MINIMUM DUAL 18 INCHES DIAMETER. THE SPEAKERS SHOULD BE COURSSE TEXTURE AND BE MADE OF EUROPEAN BIRCH PLYWOOD. ALL METAL PARTS SHOULD BE POWER COATED OR STAINELESS STEEL. Approved Makes: NEXO / L ACOUSTICS / PULZ Nos 2.00 0
24.B.3.6 Supply Install Testing & Commissioning of 7.2 Channels AVR 100 Watts per Channel 6 HDMI Inputs plus eARC 8K & Dolby Atmos HEOS Built-in Approved Makes: Marantz/Pioneer/Denon Nos 1.00 0
24.B.3.7 Supply Install Testing & Commissioning of Amplifier No.Of Channels 4 or more Output Power(per channel) >4 x 480 Watts @ 8&Omega or better 4 x 820 Watts @ 4&Omega or better 2 x 1380 Watts @ 8Ω in bridge mode or better Frequency Response 20Hz - 20kHz, +0/0.5dB or better Total Hormonic Distortion + Noise <0.1% or better Signal to Noise Ratio 110dB or better Damping factor >300 or better Crosstalk <-60dB or better Slew Rate >10V/us or better Approved Makes: NEXO / L ACOUSTICS / PULZ Nos 4.00 0
24.B.3.8 Supply, installation, testing and commissioning of 2 channel power amplifier to be used for powering Subwoofer with Output Power (per channel) 2 x 400 Watts @ 16Ω 2 x 800 Watts @ 8Ω 2 x 1300 Watts @ 4Ω 1 x 2500 Watts @ 8Ω bridge mode 1 x 3500 Watts @ 4Ω bridge mode Frequency Response 20Hz – 20kHz, +0/-0.5dB Total Harmonic Distortion + Noise <0.1% Signal to Noise Ratio 110dB Damping factor >300 Crosstalk <-60dB Slew Rate >10V/us Input Sensitivity 0.7V, 1.4V Input Impedance 20kΩ, balanced Voltage Gain 38dB at 0.7V Sensitivity Approved Makes: NEXO / L ACOUSTICS / PULZ Nos 1.00 0
24.B.3.9 Supply, installation, testing and commissioning of 3 channel power amplifier to be used for powering Green room and operators monitor speaker with output power 3 x 200 Watts @ 8Ω 3 x 300 Watts @ 4Ω Frequency Response 30Hz –20kHz, +0.2dB Total Harmonic Distortion + Noise <0.01% Intermodulation Distortion <0.02% Signal to Noise Ratio -95dB Damping factor >100 @ 8Ω Crosstalk -90dB Slew Rate 50V/us Input Sensitivity 1.3V RMS (+5dBu) Input Impedance 20kΩ, balanced Voltage Gain 29dB Approved Makes: NEXO / L ACOUSTICS / PULZ Nos 1.00 0
24.B.3.10 Suppy, Installation, Testing and Commissioning of 48 Channel Digital mixer with 33 motor faders (32 channels + 1 master), 48 input mixing channels (40 mono + 2 stereo + 2 return), 20 Aux (8 mono + 6 stereo) + Stereo + Sub buses 8 DCA groups with Roll-out, 32 analog XLR/TRS combo mic/line inputs + 2 analog RCA pin stereo line inputs, 16 analog XLR outputs, 34 x 34 digital record/playback channels via USB 2.0 + 2 x 2 via a USB storage device, 8 Effects and 10 GEQ 1 expansion slot for NY64-D audio interface card. Approved Makes: Yamaha/Pioneer/Soundcraft Nos 1.00 0
24.B.3.11 Suppy, Installation, Testing and Commissioning of Dante Expansion Card for Digital mixing Consoles Approved Makes: Yamaha/Pioneer/Soundcraft Nos 1.00 0
24.B.3.12 Suppy, Installation, Testing and Commissioning of Dante-equipped I/O rack with 16 microphone/ line inputs and 8 line outputs. Approved Makes: Yamaha/Pioneer/Soundcraft Nos 1.00 0
24.B.3.13 Supply Install Testing & Commissioning of 40x1G PoE+ 960W and 8 x SFP+ managed Switch for Dante & AVB. Approved Makes: Netgear/Cisco/HP Nos 1.00 0
24.B.3.14 Suppy, Installation, Testing and Commissioning of SFP + DAC Cable 3m Passive SFP + Direct Attach Cable Approved Makes: Netgear/Cisco/HP Nos 8.00 0
24.B.3.15 Supply , installation , testing and comissioning of Shotgun Mics Increased directivity due to interference tube system (capsule) Very low noise, high SNR High sensitivity Universal application due to M-S format, mono compatible Climate-resistant capsules Rugged brass casing, with matt black finish Pick-up patterns M: super-cardioid/lobar Frequency response 60 – 20,000 Hz, Maximum sound pressure level (passive) 130 dB (63 Pa), Output voltage 1.5 V Approved Makes: Sennhieser/Clearone/Shure Nos 8.00 0
24.B.3.16 Supply , installation , testing and comissioning of Boundry Mic The microphone shall be a cardioid pre-polarized condenser on-table boundary layer microphone designed for use in conference applications. The high-quality microphone capsule shall be optimized for speech intelligibility. The frequency response shall be 40 Hz - 20,000 Hz and sensitivity shall be 10 mV/Pa. Nominal impedance at 1 kHz shall be 200 Ω. Equivalent noise level shall be 26 dB(A) or 39 dB weighted as per CCIR 468-3. Dynamic range shall be 111 dB (A). Maximum SPL shall be 140 dB Approved Makes: Sennhieser/Clearone/Shure Nos 8.00 0
24.B.3.17 Supply , installation , testing and comissioning of Headworn Mic Approved Makes: Sennhieser/Clearone/Shure Nos 1.00 0
24.B.3.18 Supply , installation , testing and comissioning of Wired Instrument Microphone frequency response: 40-20,000 Hz output impedance: 50 ohms sensitivity: 3mBV/Pa max. SPL: 139 dB/SPL 3-15/16" length x 3/4" diameter Approved Makes: Sennhieser/Clearone/Shure Nos 4.00 0
24.B.3.19 Supply , installation , testing and comissioning of Podium Gooseneck microphone shall be a pre-polarized condenser de signed for permanent installation or portable applications. It shall have a microphone capsule with a cardioid polar pattern with uniform 120° angle of acceptance (-3 dB). It shall have a frequency response of 50 Hz to 20,000 Hz and be capable of handling sound input levels up to 130 dB SPL. Nominal equivalent noise level shall be 26 dBA (37 dB weighted as per CCIR 468-3) Approved Makes: Sennhieser/Clearone/Shure Nos 2.00 0
24.B.3.20 Supply , installation , testing and comissioning of Collar Mic Max. sound pressure level: 130 dB Polar pattern: Omnidirectional Transducer principle: Pre-polarized condenser microphone System frequency range: 470-526 MHz Operating range: 328 ft. Line-of-sight Frequency response: 20 Hz - 20 kHz Microphone type: Condenser Microphone polar pattern: Omnidirectional Max SPL: 130 dB SPL Metal housing: Durable UHF range: Ultra High Frequency Audio THD: ≤ -60 dB for 1 kHz @ -3 dBfs input level Approved Makes: Sennhieser/Clearone/Shure Nos 4.00 0
24.B.3.21 Supply , installation , testing and comissioning of Handheld Mic Max. sound pressure level: 130 dB Polar pattern: Omnidirectional Transducer principle: Pre-polarized condenser microphone System frequency range: 470-526 MHz Operating range: 328 ft. Line-of-sight Frequency response: 20 Hz - 20 kHz Microphone type: Condenser Microphone polar pattern: Omnidirectional Max SPL: 130 dB SPL Metal housing: Durable UHF range: Ultra High Frequency Audio THD: ≤ -60 dB for 1 kHz @ -3 dBfs input level Approved Makes: Sennhieser/Clearone/Shure Nos 4.00 0
24.B.3.22 Supply , installation , testing and comissioning of Singer WiredTransducer principle: dynamic Frequency response: 40 - 16,000 Hz or better, Pick-up pattern: super-cardioid, Sensitivity (free field, no load): 1.8 mV/Pa, Nominal impedance (at 1 kHz): 350 Ω or better Approved Makes: Shure/Sennheiser/Televic Nos 3.00 0
24.B.3.23 Supply , installation , testing and comissioning of two-channel digital half-rack (9,5") receiver for use with Evolution Wireless Digital handheld, bodypack and tablestand transmitters. Extended 88 MHz switching bandwidth, intermodulation-free operation for up to 293 channels with secure AES-256 encryption and redundant power supply via Power over Ethernet (PoE). Approved Makes: Sennhieser/Clearone/Shure Nos 3.00 0
24.B.3.24 Supply, installation, testing and commissioning of Full rack 19” 1RU processor mainframe with sixteen user-configured card slots . Selectable 48 & 96kHz sampling rates. Integrated license-activated AEC. Dual core processing 40-bit floating DSP Front panel OLED display with jog wheel. Rear panel includes an Ethernet module with RJ45 connector and internal power supply connection .16ch Mic/Line input with selectable mic, line, mic gain, and phantom power per input. 32-bit analog to digital converters.2ch Line output. 32-bit digital to analog converters. 2ch input + 2ch output USB audio.Software license activated AEC. 8ch of AEC @ 250ms delay / 16ch @ 100ms Approved Makes: Symetrix / XIlica / Bose Nos 1.00 0
24.B.3.25 Supply, installation, testing and commissioning of zone controller with bitmap LCD and four buttons for displaying and controlling the system settings; Fixed 6-position terminal conNeutrik XLR 2x2 to Dante in-wall module, suitable for single-gang EU/UK installation or dual-gang US electrical boxes. Single CatX for power and data. Approved Makes: Symetrix / XIlica / Bose Nos 3.00 0
24.B.3.26 Supply, installation, testing and commissioning of Antenna with Frequency range 470 – 1075 MHz Apex angle (-3 dB) approx. 100° Front-to-back ratio > 14 dB Gain typ. 5 dBi Impedance 50 Ω Connection BNC female. Approved Makes: Sennheiser/ClearOne/Televic Nos 1.00 0
24.B.3.27 Suppy, Installation, Testing and Commissioning of 100' UHF Coaxial Antenna Cable. Approved Makes: Beldon/Sennheiser/Neutrik Rmt 200.00 0
24.B.3.28 Supply, Installation, Testing & Commissioning of microphone set consisting of steel drum case; 1 nos dynamic cardioid microphone with an integral stand mount, fitted with a hum compensating coil for low frequency instruments with frequency response of 20 Hz – 16,000 Hz and the sensitivity (free field, no load) of 0.25 mV/Pa at 1 kHz and 0.9 mV/Pa at 50 Hz, nominal impedance of 350 Ω, with a min. terminating impedance of 1 kΩ; 4 nos dynamic cardioid instrument microphone for drums and percussion as well as brass and woodwind instruments featuring an integral stand mount and hum compensating coil with frequency response of 40 Hz – 18,000 Hz and the sensitivity (free field, no load) of 1.8 mV/ Pa at 1 kHz. nominal impedance of 350 Ω, with a min. terminating impedance of 1 kΩ; 2 nos super-cardioid pre-polarized condenser instrument microphone with frequency response of 40 Hz- 20,000 Hz and sensitivity of 3 mV/P at 1 kHz, Maximum SPL of 139 dB at 1 kHz. Nominal impedance of 50 Ohm, with a min. terminating impedance of 1 kOhm Approved Makes: Shure/Sennheiser/Televic Nos 2.00 0
24.B.4 LIGHTING, AUTOMATION AND CONTROL SYSTEM
24.B.4.1 Supply , installation , testing and comissioning of AV controller which is purpose built Linux server appliance provisioned specifically for controlling and managing TCP/IP endpoints on a Network. The controller shall have following features: - Processor - Intel X5-Z8350 64 bit, GPU - Intel HD Graphics, Memory - 4GB DDR3L, Storage - 64GB eMMC 5.1, Video Output - HDMI 1.4 , Mini Display Port, Peripheral Interface - RJ-45 Gigabit Ethernet, Micro SD Card Reader USB2. port x3, USB 3.1 port x1, Kensington lock ready. The controller shall be capable of controlling minimum 3 IP enabled devices on the Network. Includes License to control additional 3 or more IP devices on the Network. Approved Makes: kramer/ Crestron / Extron Nos 1.00 0
24.B.4.2 Supply, installation, testing & Commissioning of 10-11 inch Multi‑Touch display with IPS technology with Liquid Retina display, Resolution:2388x1668-pixel resolution at 264 pixels per inch (ppi), 600 nits brightness. Should be provided with docking station. Approved Makes: Apple / Crestron / Extron Nos 1.00 0
24.B.4.3 Supply, installation, testing & Commissioning of Lighting Control System (Lighting Drivers in Electrical scope) Approved Makes: Dynalight / Crestron / Lutron Nos 2.00 0
24.B.4.4 Supply, installation, testing & Commissioning of Wireless Access point Approved Makes: Netgear /Cisco/ HP Nos 1.00 0
24.B.5 CABLES AND CONNECTORS
24.B.5.1 Supply, installation, testing & Commissioning of 2 core 14 AWG/2.5 Sq mm, Twisted, unshielded Speaker cable with stranded annealed bare copper conductors, Semi-rigid PVC insulation, NEC CL3R, CEC CMG, RoHS compliant Approved Makes: Liberty AV / Beldon / Sommer Rmt 1,200.00 0
24.B.5.2 Supply, installation, testing & Commissioning of 2 core 12 AWG/4 Sq mm, Twisted, unshielded Speaker cable with stranded annealed bare copper conductors, Semi-rigid PVC insulation, NEC CL3R, CEC CMG, RoHS compliant Approved Makes: Liberty AV / Beldon / Sommer Rmt 1,200.00 0
24.B.5.3 Supply, installation, testing & Commissioning of 4 pair shielded/foiled TIA/EIA-568-C Category 6A cable with 23AWG or better Solid annealed bare copper conductors, High-density polyethylene insulation, Flame rated PVC jacket, Overall aluminum/poly foil shield with drain, NEC CMR, CEC CMR FT4, RoHS compliant. Approved Makes: Liberty AV / Beldon / Sommer Rmt 800.00 0
24.B.5.4 Supply, installation, testing & Commissioning of 2 core Twisted, shielded balanced Audio and control cable with 22AWG or better 7 strand annealed bare copper conductors, Semi-Rigid PVC insulation, Riser rated PVC jacket. UL 444, UL 13 CMR rated Approved Makes: Liberty AV / Beldon / Sommer Rmt 800.00 0
24.B.5.5 Supply, installation, testing & Commissioning of 6' High Speed HDMI with Ethernet cable for 3D, 4K, Deep Color applications and installations, 18.0Gbps Bandwidth to support 4K60 4:4:4, shall Support ARC, and all HDCP levels, HDR Certified by HDMI ATC, RoHS, REACH, and TAA Compliant, Approved Makes: Liberty AV / Kramer / Extron Nos 16.00 0
24.B.5.6 Supply, installation, testing & Commissioning of USB 3.1 C to C 6 foot cable that shall support data speed upto 5 Gbps. The cable shall be capable of providing 5A(100W) power output for charging. The cable shall be backward compatible with earlier USB genrations. The cable shall support all USB-C and thunderbolt devices. Approved Makes: Liberty AV / Kramer / Extron Nos 2.00 0
24.B.5.7 Supply, installation, testing & Commissioning of 6' USB "A" Plug (Male) to "B" Plug (Male) cable. The cable shall be 3.0 compatable but shall also suport USB 1.1 and 2.0 Approved Makes: Liberty AV / Kramer / Extron Nos 8.00 0
24.B.5.8 Supply, installation, testing & Commissioning of Various types of Cables & Connectrs Packages Lumpsum 1.00 0
24.B.5.9 Supply, installation, testing & Commissioning of Audio Visual 42 U Rack with required accessories including tray, power, cooling fan etc Approved Makes: WQ / Valrack / Dlink Nos 1.00 0
24.C STAGE LIGHTING WORKS
Light integration General points: 1.The scope includes installation of the lighting control rack/panels with proper internal wiring, professional-grade termination, and structured cable management for safe and efficient operation. 2.Complete system programming, addressing, configuration, and integration of all lighting fixtures and control systems (DMX/similar protocols) shall be carried out. 3.The system shall be thoroughly tested, commissioned, and fine-tuned to achieve the desired lighting scenes, effects, and performance as per design intent. 4.On-site user training shall be provided, covering system operation, scene control, and basic troubleshooting, followed by formal handover. 5.Power cabling for lighting fixtures shall be included unless explicitly covered under the electrical contractor’s scope. 6.Mounting, rigging, and alignment of lighting fixtures (including brackets, clamps, and safety wires) to be within the light system integrators scope only. 7.All cable lengths and routing shall be finalized based on actual site conditions and as-built measurements. 8.Proper segregation of power and control cables (DMX/network) shall be maintained to avoid interference and ensure system reliability. 9.Any deviations from the specified design or BOQ shall be clearly highlighted and brought to the consultant/client’s notice for approval prior to execution. 10.Equipment or services of higher specification or performance than those mentioned in the BOQ are acceptable, subject to approval. 11.Adequate provisions for power distribution, load balancing, and protection (including dimmers, relays, and surge protection where applicable) shall be ensured. 12.Safe storage of all lighting equipment during the installation phase shall be ensured, with prior arrangement and responsibility clearly defined. 13.Before turning on the electronics, a proper check of incoming electrical reading is responsibility of lighting system integrator. Any damage to the equipment will be solely responsibility of the lighting system integrator.
24.C.1 Supply, Installation, Testing & Commissioning of SITC of 150W Led Fresnel Spot Light. (Single - color) Specifications: High TLCI & CRI > 95, Beam spread: 10°- 60°, Color Temp: 3200K, Dimming: Manual as well as DMX. Approved Makes: Kinoflo / Shenoy / Lite Panels/ ETC Nos 8.00 0
24.C.2 Supply Install Testing & Commissioning of SITC of 300W Led Profile Spot Light - (Single - color) Specifications: Color Temp: 3200K, Dimming: Manual as well as DMX. Approved Makes: Kinoflo / Shenoy / Lite Panels/ ETC Nos 2.00 0
24.C.3 Supply Install Testing & Commissioning of SITC of LED Blinder - 400W - (Single - color) Specifications: Color Temp: 3200K Approved Makes: Kinoflo / Shenoy / Lite Panels/ ETC Nos 11.00 0
24.C.4 Supply Install Testing & Commissioning of SITC of S150T Led Fresnel Spot Light. (Single - color) S150T is a Premium Quality, Well designed & Engineered, Versatile Led Fresnel Spot Light. Specifications: High TLCI & CRI > 95, Beam spread: 10°- 60°, Color Temp: 3200K, Dimming: Manual as well as DMX. Approved Makes: Kinoflo / Shenoy / Lite Panels/ ETC Nos 5.00 0
24.C.5 Suppy, Installation, Testing and Commissioning of SITC of 3W x 54 RGBW LED PAR Voltage: AC220V, Lamp: 3W x 54, Channel: 8CH, Function: DMX 512 control. Approved Makes: Kinoflo / Shenoy / Lite Panels/ ETC Nos 12.00 0
24.C.6 Suppy, Installation, Testing and Commissioning of SITC of LED PAR- (Single - color) Voltage: AC220V, Color Temp: 3200K, Function: DMX 512 control. Approved Makes: Kinoflo / Shenoy / Lite Panels/ ETC Nos 6.00 0
24.C.7 Supply Install Testing & Commissioning of Aluminium C Type clamp 40mm bolt and wing nut for pipe locking. Approved Makes: Kinoflo / Shenoy / Lite Panels/ ETC Nos 44.00 0
24.C.8 Suppy, Installation, Testing and Commissioning of Light Fixture dual safety Chain made up of GI wire rope. Approved Makes: Kinoflo / Shenoy / Lite Panels/ ETC Nos 44.00 0
24.C.9 Supply, Installation, Testing and comissioning of Suspender. MS Fabricated Suspenders to be designed as per site condition with clamps and requisite fastners. Approved Makes: Kinoflo / Shenoy / Lite Panels/ ETC Nos 17.00 0
24.C.10 Supply, Installation, Testing and Comissioning of Fixed Lighting bar (8mtr), Using MS Pipe & Black Powder coated. MS Fabricated Suspenders to be designed as per site condition with clamps and requisite fastners. Approved Makes: Kinoflo / Shenoy / Lite Panels/ ETC Nos 2.00 0
24.C.11 Supply, Installation, Testing and Comissioning of Fixed Lighting bar (7mtr) . using MS Pipe & Black Powder coated. MS Fabricated Suspenders to be designed as per site condition with clamps and requisite fastners. Approved Makes: Kinoflo / Shenoy / Lite Panels/ ETC Nos 1.00 0
24.C.12 Supply, Installation, Testing and Comissioning of FOH Fixed Lighting bar (9mtr) . using MS Pipe & Black Powder coated. MS Fabricated Suspenders to be designed as per site condition with clamps and requisite fastners. Approved Makes: Kinoflo / Shenoy / Lite Panels/ ETC Nos 1.00 0
24.C.13 Supply, Installation, Testing and Comissioning of Power distribution centre panel with necessary metering, outgoing feeders and Incomer and emergency trip arrangement (PDCP) And MCB Panel to control individual light points. Approved Makes: Seimens/ L&T / Shenoy Nos 1.00 0
24.C.14 Supply, Installation, Testing and Comissioning of 4 Way Junction Box fitted with mount Connectors Provided with Cable gland & necessary Clamping. Approved Makes: LL / Nuetrick/ Lyt Master / Shenoy Nos 21.00 0
24.C.15 Supply, Installation, Testing and Comissioning of 2 Way Junction Box fitted with mount Connectors Provided with Cable gland & necessary Clamping. Approved Makes: LL / Nuetrick/ Lyt Master / Shenoy Nos 1.00 0
24.C.16 Supply, Installation, Testing and Comissioning of DMX Signal Junction Box fitted with 3 pin panel mount female connectors, necessary gland and mounting brackets. Approved Makes: LL / Nuetrick/ Lyt Master / Shenoy Nos 1.00 0
24.C.17 Supply, Installation, Testing and Comissioning of DMX Signal Junction Box fitted with 3 pin panel mount female connectors, necessary gland and mounting brackets. Approved Makes: LL / Nuetrick/ Lyt Master / Shenoy Nos 8.00 0
24.C.18 Supply, installation, testing and commissioning of DmX Loop Signal Junction Box fitted with 3 pin panel mount female connectors, necessary gland and mounting brackets. Approved Makes: LL / Nuetrick/ Lyt Master / Shenoy Nos 1.00 0
24.C.19 Supply, Installation, Testing and Comissioning of Bare copper earthing wire for internal earthing network Approved Makes: Polycab / RR Cable/ Jupiter Nos 1.00 0
24.C.20 Supply, Installation, Testing and Comissioning of Black Powder coated cable trays size of 40 x 150 x 40mm. Approved Makes: Custom Rmt 20.00 0
24.C.21 Supply, Installation, Testing and Comissioning of Black Powder coated cable trays size of 40 x 75 x 40mm. Approved Makes: Custom Nos 45.00 0
24.C.22 Supply, Installation, Testing and Comissioning of DmX Male Connectors 3 Pin having rubber sheeth protection for Cross connecting DmX wiring connections. Approved Makes: LL / Nuetrick/ Lyt Master / Shenoy Nos 10.00 0
24.C.23 Supply, Installation, Testing and Comissioning of DmX Female Connector 3 Pin soldered with required capacity of resistor for signal deframing. Approved Makes: LL / Nuetrick/ Lyt Master / Shenoy Nos 8.00 0
24.C.24 Supply, Installation, Testing and Comissioning of 8 Ch. DmX splitter with, 8 Isolated outputs, Mounting brackets for grid mount. Approved Makes: Shenoy / Lite Puter / Avolite Nos 1.00 0
24.C.25 Suppy, Installation, Testing and Commissioning of 3 Core x 1.5 SQ. mm Copper Flexible Cable. Approved Makes: Polycab / RR Cable/ Jupiter Rmt 400.00 0
24.C.26 Supply, Installation, Testing and Comissioning of DMX Signal Cable for DMX Network. Approved Makes: Kinoflo / Shenoy / Lite Panels/ ETC Rmt 200.00 0
24.C.27 Installation Testing commissioning and Training Lumpsum 1.00 0
24.C.28 Supply, Installation, Testing and Comissioning of SITC of DMX Lighting Console. Product Code: DMX Console - 2. DmX Touch Screen based controller having 7” Multi touch screen Approved Makes: Shenoy / Lite Puter / Avolite Nos 1.00 0
TOTAL OF ACOUSTIC & AV WORK 0
25 SIGNAGE & WAYFINDING WORKS
NOTES: 1. All items include complete supply, fabication, transportation and installation at site. 2. Concrete foundation, electricity & water to be provided at the installation site by DoAM. 3. All items include fabrication of prototypes for testing and approval from the signage design consultant and DoAM. 4. Prototypes and samples to be made available at Delhi NCR for approval from the signage design consultant. 5. All shop drawings to be structurally certified by vendor and approved by the signage design consultant before production. 6. All print ready artworks to be approved by the signage design consultant before production. 7. All material and colour / shade samples to be approved by signage design consultant before production. 8. All coatings, finishings, third party products (3M etc.) to be of certified exterior grade with suitable warranty provided to DoAM. 9. Typeface License : CMA to include Purchase of standalone desktop and server licenses for 'November' Typeface Family in Latin, Devanagari, and Gujarati scripts (upto 3 weights in each), for use by GVM, including 5 third-party licenses, perpetual term, for print, static image, and digital publishing as per TPTQ foundry specifications.
25.A FRONT OF HOUSE
25.A.1 DI01 - Vehicular Directional Totem Large Production & Installation of Totem (Large) Sign as per design intent drawings, artworks & specifications. The stuctural internal framework shall be constructed using powder coated 60x60x3 mm GS SHS. The 12mm thk GS base plate shall be anchored to an RCC foundation (M25 grade) with J-bolts, as per structural details. The sign panel shall be fabricated using sintered stone or engineered stone (upto 15mm thick) with finish to match the wall stone and approved sample. The stone shall be fixed on the framework using exterior grade VHB tape (3M 5952 or equivalent) and M4 counter-sunk screws as per design drawings. Sign panel to have a 3mm thk aluminium sheet feature cladding as per master artwork and design intent drawings . The sign panel shall feature sign content CNC-cut 3mm thk aluminium solid cut letters finished with a PU/PVDF and pasted directly on the sign panel using exterior grade VHB tape (3M 5952 or equivalent) as per the approved master artwork, content schedule and design intent drawings. Dimensions: Totem: 4200 x 1200 x 150 Foundation: 1200 x 1700 x 650 Nos 1.00 0
25.A.2 DI02 - Pedestrian Directional Totem Small Production & Installation of Totem (Small) Sign as per design intent drawings, artworks & specifications. The stuctural internal framework shall be constructed using powder coated 50x50x3 mm GS SHS. The 12mm thk GS base plate shall be anchored to an RCC foundation (M25 grade) with J-bolts, as per structural details. The sign panel shall be fabricated using sintered stone or engineered stone (upto 10mm thick) with finish to match the wall stone and approved sample. The stone shall be fixed on the framework using exterior grade VHB tape (3M 5952 or equivalent) and M4 counter-sunk screws as per design drawings. Sign panel to have a 3mm thk aluminium sheet feature cladding as per master artwork and design intent drawings . The sign panel shall feature sign content CNC-cut 3mm thk aluminium solid cut letters finished with a PU/PVDF and pasted directly on the sign panel using exterior grade VHB tape as per the approved master artwork, content schedule and design intent drawings. Dimensions: Totem: 2600 x 650 x 150 mm Foundation: 900 x 1150 x 650 Nos 4.00 0
25.A.3 DI03 - Internal Directional A Letter Mount A (Cluster 02) Production & Installation of Letter Mount A (Cluster 02) comprising three components- Letter mount A, Metal strip & Braille Panel as per design intent drawings, artworks & specifications. The 'Letter Mount A' letters and 'Metal Strip' shall be fabricated using 5 mm thk Aluminum (6061) CNC cut and finished with PU/PVDF coating in the approved shade. Threaded aluminium studs shall be welded directly on the cut letters as per design intent drawings. The 'Metal strip' shall also incorporate a 12V LED strip adhered to its reverse side to create a halo illumination effect. Both the letters and the metal strip shall be mounted directly onto the wall substrate using silicone-based adhesive. The 'Braille panel' shall incorporate 3mm thk aluminum panel with brailled raster beads press-fit into laser drilled holes. The braille panel shall be affixed to the wall surface using VHB tape (3M 5952 or equivalent). Assembly of all the components, sign content to be as per design intent drawings, master artworks and content schedule. Dimensions: Text Height: 45mm Braille Text Height: 7mm Nos 10.00 0
25.A.4 DI04 - Internal Directional B Letter Mount A (Cluster 02) Production & Installation of Letter Mount A (Cluster 02) comprising three components- Letter mount A, Metal strip & Braille Panel as per design intent drawings, artworks & specifications. The 'Letter Mount A' letters and 'Metal Strip' shall be fabricated using CNC cut 5 mm thk Aluminum (6061) finished with PU/PVDF coating in the approved shade. Threaded aluminium studs shall be welded directly on the cut letters as per design intent drawings. The 'Metal strip' shall also incorporate a 12V LED strip adhered to its reverse side to create a halo illumination effect. Both the letters and the metal strip shall be mounted directly onto the wall substrate using silicone-based adhesive. The 'Braille panel' shall incorporate 3mm thk aluminum panel with brailled raster beads press-fit into laser drilled holes. The braille panel shall be affixed to the wall surface using VHB tape (3M 5952 or equivalent) All sign content shall be as per master artwork and content schedule. Dimensions: Text Height: 30, 40mm Braille Text Height: 7mm Nos 8.00 0
25.A.5 DI05 - Utility Directional Edge Mount Production & Installation of Edge Mount Sign as per design intent drawings, artworks & specification. The structural internal framework shall be constructed using 6mm thk powder coated MS flats with M10 studs welded directly onto the framework as per design intent drawings. The sign panel shall be fabricated using 15mm thk sandstone on both sides to match the wall and approved sample. The sandstone sheet shall be fixed on the framework using exterior grade VHB tape (3M 5952 or equivalent) and M4 counter-sunk screws as per design drawings. The sign panel shall feature sign content CNC-cut 3mm thk aluminium solid cut letters as per the approved master artwork and content schedule. The aluminium letters to be finished with a PU/PVDF and pasted directly on the sign panel using exterior grade VHB tape. Complete sign unit shall be mounted directly to the wall substrate using silicone-based adhesive. Dimensions: Panel: 200 x 720 x 36 mm Nos 33.00 0
25.A.6 ID11 - Spot Identification Totem Small Production & Installation of Totem (Small) Sign as per design intent drawings, artworks & specifications. The stuctural internal framework shall be constructed using powder coated 50x50x3 mm GS SHS. The 12mm thk GS base plate shall be anchored to an RCC foundation (M25 grade) with J-bolts, as per structural details. The sign panel shall be fabricated using sintered stone or engineered stone (upto 10mm thick) with finish to match the wall stone and approved sample. The stone shall be fixed on the framework using exterior grade VHB tape (3M 5952 or equivalent) and M4 counter-sunk screws as per design drawings. Sign panel to have a 3mm thk aluminium sheet feature cladding as per master artwork and design intent drawings . The sign panel shall feature sign content CNC-cut 3mm thk aluminium solid cut letters finished with a PU/PVDF and pasted directly on the sign panel using exterior grade VHB tape as per the approved master artwork, content schedule and design intent drawings. Dimensions: Totem: 2400 x 650 x 100 mm Foundation: 900 x 1150 x 650 Nos 2.00 0
25.A.7 ID13 - Amenity Identification Letter Mount (Cluster 03) Production & Installation of Letter Mount A (Cluster 03) comprising three components- Letter Mount A, LED Display (Small) & Braille Panel as per design intent drawings, artworks & specifications. The 'Letter Mount A' letters shall be CNC-cut from 5 mm thk Aluminum (6061) finished with PU/PVDF coating in the approved shade. Threaded aluminium studs to be welded directly on the cut letters as per design intent drawings. The letters shall be mounted directly to the wall substrate using silicone-based adhesive The 'LED Display (Small)' shall incorporate a custom commercial-grade bar-type LED display (P4), with overall dimensions of 75 mm × 700 mm × 30 mm. The unit shall include an integrated metal strip housing a 12V LED for halo illumination. The complete assembly shall be mounted onto the wall substrate using a VESA-compliant mounting bracket, as per design intent drawings. The 'Braille Panel' shall consist of a 3 mm thick aluminum plate with Braille raster beads press-fit into precision laser-drilled holes. This plate shall be affixed to a 2 mm thick galvanized steel (GS) backing plate using VHB tape. The GS backing shall include welded studs and shall be mounted onto the sandstone cladding using a compatible silicone-based structural adhesive. Assembly of all the components, sign content to be as per design intent drawings, master artworks and content schedule. Dimensions: Text Height: 60mm Braille Text Height: 7mm Nos 7.00 0
25.A.8 ID14 - Room Identification Glass Graphics Production & Installation of Glass Graphics as per design intent drawings, artworks & specifications. The sign content to be digitally printed on 3M clear view vinyl (series 3650 or equivalent) as per master artwork and content schedule. Dimensions: Text Height: 50mm Braille Text Height: 7mm Nos 3.00 0
25.A.9 ID15 - Lift/Stairs/Ramp Identification Letter Mount A (Cluster 01) Production & Installation of Letter Mount A (Cluster 01) comprising two components- Letter Mount A & Braille Panel as per design intent drawings, artworks & specifications. The 'Letter Mount A' letters shall be CNC-cut from 5 mm thk Aluminum (6061) finished with PU/PVDF coating in the approved shade. Threaded aluminium studs to be welded directly on the cut letters as per design intent drawings. The letters shall be mounted directly to the wall substrate using silicone-based adhesive The 'Braille Panel' shall consist of a 3 mm thick aluminum plate with Braille raster beads press-fit into precision laser-drilled holes. This plate shall be affixed to a 2 mm thick galvanized steel (GS) backing plate using VHB tape. The GS backing shall include welded studs and shall be mounted onto the sandstone cladding using a compatible silicone-based structural adhesive.Assembly of all the components, sign content to be as per design intent drawings, master artworks and content schedule. Dimensions: Text Height: 50mm Braille Text Height: 7mm Nos 31.00 0
25.A.10 ID16 - Floor Identification Letter Mount A (Cluster 01) Production & Installation of Letter Mount A (Cluster 01) comprising two components- Letter Mount A & Braille Panel as per design intent drawings, artworks & specifications. The 'Letter Mount A' letters shall be CNC-cut from 5 mm thk Aluminum (6061) finished with PU/PVDF coating in the approved shade. Threaded aluminium studs to be welded directly on the cut letters as per design intent drawings. The letters shall be mounted directly to the wall substrate using silicone-based adhesive The 'Braille Panel' shall consist of a 3 mm thick aluminum plate with Braille raster beads press-fit into precision laser-drilled holes. This plate shall be affixed to a 2 mm thick galvanized steel (GS) backing plate using VHB tape. The GS backing shall include welded studs and shall be mounted onto the sandstone cladding using a compatible silicone-based structural adhesive. Assembly of all the components, sign content to be as per design intent drawings, master artworks and content schedule. Dimensions: Text Height: 50, 120mm Braille Text Height: 7mm Nos 24.00 0
25.A.11 ID17 - Gallery Identification Letter Mount A (Cluster 04) Production & Installation of Letter Mount A (Cluster 04) comprising three components- Letter Mount A, LED Display (Large), Metal Strip & Braille Panel as per design intent drawings, artworks & specifications. The 'Letter Mount A' letters shall be CNC-cut from 5 mm thk Aluminum (6061) finished with PU/PVDF coating in the approved shade. Threaded aluminium studs to be welded directly on the cut letters as per design intent drawings. The letters shall be mounted directly to the wall substrate using silicone-based adhesive. The 'LED Display (Large)' shall incorporate a 43" commercial-grade display screen (Samsung, LG or equivalent) mounted on the load bearing wall substrate using VESA 200 x 200 compliant push-pull mounting brackets. The 'Metal strip' shall be fabricated from 1.5 mm thick aluminum bent to shape, housing a 12V LED strip for halo illumination effect. The 'Metal strip' shall be fixed onto the sandstone cladding using studs and silicone based adhesive. The 'Braille Panel' shall consist of a 3 mm thick aluminum plate with Braille raster beads press-fit into precision laser-drilled holes. This plate shall be affixed to a 2 mm thick galvanized steel (GS) backing plate using VHB tape. The GS backing shall include welded studs and shall be mounted onto the sandstone cladding using a compatible silicone-based structural adhesive. Assembly of all the components, sign content to be as per design intent drawings, master artworks and content schedule. Dimensions: Text Height: 75mm Braille Text Height: 7mm Nos 7.00 0
25.A.12 ID18 - Entry/Exit Identification Glass Graphic Production & Installation of Glass Graphics as per design intent drawings, artworks & specifications. The sign content to be digitally printed on 3M clear view vinyl (series 3650 or equivalent) as per master artwork and content schedule. Dimensions: Text Height: 65mm Braille Text Height: 7mm Nos 2.00 0
25.A.13 ID19 - Utility Identification Door Mount Production & Installation of Door Mount as per design intent drawings, artworks & specification. The sign shall be fabricated using 3mm thk Aluminum solid cut letters finished with PU/PVDF coating in the approved shade. Sign content as per master artwork & content schedule. The sign shall be mounted directly to the door using exterior grade VHB tape (3M 5952 or equivalent). Dimensions: Icon Height: 200mm Nos 30.00 0
25.A.14 ID20 - Gate Identification Letter Mount A Production & Installation of Letter Mount A sign as per design intent drawings, artworks & specifications. The 'Letter Mount A' letters shall be CNC-cut from 5 mm thk Aluminum (6061) finished with PU/PVDF coating in the approved shade. Threaded aluminium studs to be welded directly on the cut letters as per design intent drawings. The letters shall be mounted directly to the wall substrate using silicone-based adhesive Sign content to be as per design intent drawings, master artworks and content schedule. Dimensions: Text Height: 100, 250mm Braille Text Height: 7mm Nos 3.00 0
25.A.15 ID21 - Property Identification Letter Mount B Production & Installation of Letter Mount B sign as per design intent drawings, artworks & specifications. The 'Letter Mount B' channel cut letter letters shall be CNC-cut from 5 mm thk Aluminum (6061) with an overall depth of 100mm finished with PU/PVDF coating in the approved shade. Each letter shall be internally illuminated using 5000K LED modules, and fitted with a 3 mm thick acrylic diffuser overlaid with 3M Dual-Color Film (3635-222) in the approved shade. Threaded aluminum studs shall be welded directly to the rear of each cut letter as per design drawings. The letters shall be mounted directly onto the wall substrate using a silicone-based adhesive. Sign content to be as per design intent drawings, master artworks and content schedule. Dimensions: Text Height: 300mm Braille Text Height: 7mm Nos 2.00 0
25.A.16 I41 - Orientation Map Double Post Angled Production & Installation of Double Post Angled as per design intent drawings, artworks & specifications. The stuctural internal framework shall be constructed using powder coated 70x70x3.6 mm GS SHS. The post shall be mounted on a 150mm thk base plate. The sign panel shall be fabricated using 25mm thk sandstone mounted over the SHS frame. The sandstone shall be fixed on the framework using exterior grade VHB tape (3M 5952 or equivalent) and M4 counter-sunk screws as per design drawings. The sign panel shall feature sign content CNC-cut 3mm thk aluminium solid cut letters finished with a PU/PVDF and pasted directly on the sign panel using exterior grade VHB tape (3M 5952 or equivalent) as per the approved master artwork, content schedule and design intent drawings. Dimensions: Panel Size: 1800 x 900 mm Nos 1.00 0
25.A.17 I42 - Gallery Level Orientation Letter Mount A (Cluster 01) Production & Installation of Letter Mount A (Cluster 01) comprising two components- Letter Mount A & Braille Panel as per design intent drawings, artworks & specifications. The 'Letter Mount A' letters shall be CNC-cut from 5 mm thk Aluminum (6061) finished with PU/PVDF coating in the approved shade. Threaded aluminium studs to be welded directly on the cut letters as per design intent drawings. The letters shall be mounted directly to the wall substrate using silicone-based adhesive The 'Braille Panel' shall consist of a 3 mm thick aluminum plate with Braille raster beads press-fit into precision laser-drilled holes. This plate shall be affixed to a 2 mm thick galvanized steel (GS) backing plate using VHB tape. The GS backing shall include welded studs and shall be mounted onto the sandstone cladding using a compatible silicone-based structural adhesive. Assembly of all the components, sign content to be as per design intent drawings, master artworks and content schedule. Dimensions: Text Height: 20, 60mm Braille Text Height: 7mm Nos 10.00 0
25.A.18 I43 - Rules and Regulations Glass Graphic Production & Installation of Glass Graphics as per design intent drawings, artworks & specifications. The sign content to be digitally printed on 3M clear view vinyl (series 3650 or equivalent) as per master artwork and content schedule. Dimensions: Text Height: 20, 60mm Braille Text Height: 7mm Nos 1.00 0
25.A.19 I44 - Interpretative Map Double Post Angled Production & Installation of Double Post Angled as per design intent drawings, artworks & specifications. The stuctural internal framework shall be constructed using powder coated 70x70x3.6 mm GS SHS. The post shall be mounted on a 150mm thk base plate. The sign panel shall be fabricated using 25mm thk sandstone mounted over the SHS frame. The sandstone shall be fixed on the framework using exterior grade VHB tape (3M 5952 or equivalent) and M4 counter-sunk screws as per design drawings. The sign panel shall feature sign content CNC-cut 3mm thk aluminium solid cut letters finished with a PU/PVDF and pasted directly on the sign panel using exterior grade VHB tape (3M 5952 or equivalent) as per the approved master artwork, content schedule and design intent drawings. Dimensions: Panel Size: 1800 x 900 mm Nos 1.00 0
25.B BACK OF HOUSE
25.B.1 BOH90 - Area Identification Wall Mount Providing and fixing Wall Mount signage panel, fabricated from 3 mm thick aluminium (6061) sheet, CNC cut and folded as per approved design, with PU coating paint finish in approved shade. The panel shall feature sign content in CNC cut vinyl (3M 7725 series or equivalent) as well as Braille content in raised SS braille dots with a height of 0.6mm and dia of 1.6 mm conforming to relevant ISO standards and ADA guidelines. Dimenions: Panel Size: 350mm x 150mm Nos 26.00 0
25.B.2 BOH91 - Room Identification Wall Mount Providing and fixing Wall Mount signage panel, fabricated from 3 mm thick aluminium (6061) sheet, CNC cut and folded as per approved design, with PU coating paint finish in approved shade. The panel shall feature sign content in CNC cut vinyl (3M 7725 series or equivalent) as well as Braille content in raised SS braille dots with a height of 0.6mm and dia of 1.6 mm conforming to relevant ISO standards and ADA guidelines. Dimensions: Panel Size: 450mm x 300mm; 200mm x 105mm Nos 82.00 0
25.B.3 BOH92 - Utility Identification Wall Mount Providing and fixing Wall Mount signage panel, fabricated from 3 mm thick aluminium (6061) sheet, CNC cut and folded as per approved design, with PU coating paint finish in approved shade. The panel shall feature sign content in CNC cut vinyl (3M 7725 series or equivalent) as well as Braille content in raised SS braille dots with a height of 0.6mm and dia of 1.6 mm conforming to relevant ISO standards and ADA guidelines. Dimensions: Panel Size: 270mm x 150mm Nos 40.00 0
25.B.4 BOH94 - Lift/Stairs/Ramp Identification Wall Mount Providing and fixing Wall Mount signage panel, fabricated from 3 mm thick aluminium (6061) sheet, CNC cut and folded as per approved design, with PU coating paint finish in approved shade. The panel shall feature sign content in CNC cut vinyl (3M 7725 series or equivalent) as well as Braille content in raised SS braille dots with a height of 0.6mm and dia of 1.6 mm conforming to relevant ISO standards and ADA guidelines. Dimensions: Panel Size: 250mm x 250mm Nos 17.00 0
25.B.5 BOH95 - Floor Identification Wall Mount Providing and fixing Wall Mount signage panel, fabricated from 3 mm thick aluminium (6061) sheet, CNC cut and folded as per approved design, with PU coating paint finish in approved shade. The panel shall feature sign content in CNC cut vinyl (3M 7725 series or equivalent) as well as Braille content in raised SS braille dots with a height of 0.6mm and dia of 1.6 mm conforming to relevant ISO standards and ADA guidelines. Dimensions: Panel Size: 350mm x 150mm Nos 17.00 0
25.B.6 BOH96 - Entry/Exit Identification Wall Mount Providing and fixing Wall Mount signage panel, fabricated from 3 mm thick aluminium (6061) sheet, CNC cut and folded as per approved design, with PU coating paint finish in approved shade. The panel shall feature sign content in CNC cut vinyl (3M 7725 series or equivalent) as well as Braille content in raised SS braille dots with a height of 0.6mm and dia of 1.6 mm conforming to relevant ISO standards and ADA guidelines. Dimensions: Panel Size: 250mm x 250mm Nos 2.00 0
25.B.7 BOH97 - Gallery Identification Wall Mount Providing and fixing Wall Mount signage panel, fabricated from 3 mm thick aluminium (6061) sheet, CNC cut and folded as per approved design, with PU coating paint finish in approved shade. The panel shall feature sign content in CNC cut vinyl (3M 7725 series or equivalent) as well as Braille content in raised SS braille dots with a height of 0.6mm and dia of 1.6 mm conforming to relevant ISO standards and ADA guidelines. Dimensions: Panel Size: 450mm x 200mm Nos 5.00 0
25.B.8 BOH98 - Rules And Regulations Wall Mount Production & Installation of Glass Graphics as per design intent drawings, artworks & specifications. The sign content to be digitally printed on 3M clear view vinyl (series 3650 or equivalent) as per master artwork and content schedule. Dimensions: Text Height: 20, 60mm Braille Text Height: 7mm Nos 1.00 0
25.B.9 BOH100 - Utility Directional Edge Mount Production & Installation of Edge Mount Sign as per design intent drawings, artworks & specification. The structural internal framework shall be constructed using 32x32mm powder coated MS SHS with M10 studs welded directly onto the framework as per design intent drawings. The sign panel shall be fabricated using 3mm thk aluminium CNC-cut and folded to shape and finished to match the wall stone and approved sample. The GFRP sheet shall be fixed on the framework using exterior grade VHB tape (3M 5952 or equivalent) and M4 counter-sunk screws as per design drawings. Sign content shall be printed on exterior-grade 3M non-reflective vinyl film, aligned with the sign type layout and content schedule, and applied as per the vinyl manufacturer’s specifications. Complete sign unit shall be mounted directly to the wall substrate using silicone-based adhesive. Dimensions: Panel Size: 150 x 550 x 40 mm Nos 22.00 0
25.C REGULATORY
25.C.1 R61 - Access Regulatory Wall Mount Providing and fixing Wall Mount signage panel, fabricated from 3 mm thick aluminium (6061) sheet, CNC cut and folded as per approved design, with PU coating paint finish in approved shade. The panel shall feature sign content in CNC cut vinyl (3M 7725 series or equivalent) as well as Braille content in raised SS braille dots with a height of 0.6mm and dia of 1.6 mm conforming to relevant ISO standards and ADA guidelines. Dimensions: Panel Size: 250mm x 180mm Nos 9.00 0
25.C.2 R62 - Warning Regulatory Wall Mount Providing and fixing Wall Mount signage panel, fabricated from 3 mm thick aluminium (6061) sheet, CNC cut and folded as per approved design, with PU coating paint finish in approved shade. The panel shall feature sign content in CNC cut vinyl (3M 7725 series or equivalent) as well as Braille content in raised SS braille dots with a height of 0.6mm and dia of 1.6 mm conforming to relevant ISO standards and ADA guidelines. Dimensions: Panel Size: 250mm x 180mm Nos 15.00 0
25.D FIRE AND LIFE SAFETY
25.D.1 FLS71 - Accessible Exit Identification Wall Mount/Back-Lit Non maintained, Rectangular- Recessed mounted egress light, IP20 rated, minimum 3 hours backup, 11W CFL/6W LED, safety-mains operated, Ni-Mh/Ni-Cd Rechargeable battery, ABS housing body finished in powder coating, customised to color as per specification. Artwork on one side. Signage to be mounted using appropriate fasteners. Dimensions: Panel Size: 575mm X 200mm Nos 52.00 0
25.D.2 FLS72 - Exit Identification Wall Mount/Back-Lit Non maintained, Rectangular- Recessed mounted egress light, IP20 rated, minimum 3 hours backup, 11W CFL/6W LED, safety-mains operated, Ni-Mh/Ni-Cd Rechargeable battery, ABS housing body finished in powder coating, customised to color as per specification. Artwork on one side. Signage to be mounted using appropriate fasteners. Dimensions: Panel Size: 450mm X 200mm Nos 31.00 0
25.D.3 FLS7301 - Overhead Exit Directional A Wall Mount Sign panel to be fabricated using 1.5 mm thk MS sheet. Sign panel to be finished with photoluminiscent PU coating in specified color as per design intent. Thin MS mounting plate with anti-rust coating fixed onto wall using counter-sunk screws with plastic plug. Sign panel to be pasted on MS mounting plate using 3M VHB tape. Sign content and graphics to be printed on 3M clear view film as per sign type layout (master artworks) and pasted on sign panel as per vinyl manufacturers specifications. Dimensions: Panel Size: 625mm X 200mm Nos 26.00 0
25.D.4 FLS74 - Staircase Exit Directional Wall Mount Sign panel to be fabricated using 1.5 mm thk MS sheet. Sign panel to be finished with photoluminiscent PU coating in specified color as per design intent. Thin MS mounting plate with anti-rust coating fixed onto wall using counter-sunk screws with plastic plug. Sign panel to be pasted on MS mounting plate using 3M VHB tape. Sign content and graphics to be printed on 3M clear view film as per sign type layout (master artworks) and pasted on sign panel as per vinyl manufacturers specifications. Dimensions: Panel Size: 300mm X 150mm Nos 92.00 0
25.D.5 FLS75 - Equipment Identification Wall Mount Sign panel to be fabricated using 1.5 mm thk MS sheet. Sign panel to be finished with photoluminiscent PU coating in specified color as per design intent. Thin MS mounting plate with anti-rust coating fixed onto wall using counter-sunk screws with plastic plug. Sign panel to be pasted on MS mounting plate using 3M VHB tape. Sign content and graphics to be printed on 3M clear view film as per sign type layout (master artworks) and pasted on sign panel as per vinyl manufacturers specifications. Braille content cut in 2mm thk PMMA to be pasted over sign panel as per design intent. Dimensions: Panel Size: 250mm X 350mm Nos 81.00 0
25.D.6 FLS76 - Equipment Identification -Graphic Wall Mount Sign panel to be fabricated using 1.5 mm thk MS sheet. Sign panel to be finished with photoluminiscent PU coating in specified color as per design intent. Thin MS mounting plate with anti-rust coating fixed onto wall using counter-sunk screws with plastic plug. Sign panel to be pasted on MS mounting plate using 3M VHB tape. Sign content and graphics to be printed on 3M clear view film as per sign type layout (master artworks) and pasted on sign panel as per vinyl manufacturers specifications. Dimensions: Panel Size: 350mm X 250mm Nos 40.00 0
25.D.7 FLS77 - Fire Lift Identification Wall Mount Sign panel to be fabricated using 1.5 mm thk MS sheet. Sign panel to be finished with photoluminiscent PU coating in specified color as per design intent. Thin MS mounting plate with anti-rust coating fixed onto wall using counter-sunk screws with plastic plug. Sign panel to be pasted on MS mounting plate using 3M VHB tape. Sign content and graphics to be printed on 3M clear view film as per sign type layout (master artworks) and pasted on sign panel as per vinyl manufacturers specifications. Dimensions: Panel Size: 250mm X 300mm Nos 11.00 0
25.D.8 FLS78 - Staircase Floor Identification Wall Mount Sign panel to be fabricated using 1.5 mm thk MS sheet. Sign panel to be finished with photoluminiscent PU coating in specified color as per design intent. Thin MS mounting plate with anti-rust coating fixed onto wall using counter-sunk screws with plastic plug. Sign panel to be pasted on MS mounting plate using 3M VHB tape. Sign content and graphics to be printed on 3M clear view film as per sign type layout (master artworks) and pasted on sign panel as per vinyl manufacturers specifications. Dimensions: Panel Size: 250mm X 350mm Nos 31.00 0
25.D.9 FLS79 - Fire Regulatory Wall Mount Sign panel to be fabricated using 1.5 mm thk MS sheet. Sign panel to be finished with photoluminiscent PU coating in specified color as per design intent. Thin MS mounting plate with anti-rust coating fixed onto wall using counter-sunk screws with plastic plug. Sign panel to be pasted on MS mounting plate using 3M VHB tape. Sign content and graphics to be printed on 3M clear view film as per sign type layout (master artworks) and pasted on sign panel as per vinyl manufacturers specifications. Dimensions: Panel Size: 400mm X 150mm Nos 31.00 0
25.D.10 FLS80 - Fire Regulatory with Braille Wall Mount Sign panel to be fabricated using 1.5 mm thk MS sheet. Sign panel to be finished with photoluminiscent PU coating in specified color as per design intent. Thin MS mounting plate with anti-rust coating fixed onto wall using counter-sunk screws with plastic plug. Sign panel to be pasted on MS mounting plate using 3M VHB tape. Sign content and graphics to be printed on 3M clear view film as per sign type layout (master artworks) and pasted on sign panel as per vinyl manufacturers specifications. Braille content cut in 2mm thk PMMA to be pasted over sign panel as per design intent. Dimensions: Panel Size: 400mm X 200mm Nos 31.00 0
25.D.11 FLS81 - Fire Information Wall Mount Sign panel to be fabricated using 1.5 mm thk MS sheet. Sign panel to be finished with photoluminiscent PU coating in specified color as per design intent. Thin MS mounting plate with anti-rust coating fixed onto wall using counter-sunk screws with plastic plug. Sign panel to be pasted on MS mounting plate using 3M VHB tape. Sign content and graphics to be printed on 3M clear view film as per sign type layout (master artworks) and pasted on sign panel as per vinyl manufacturers specifications. Dimensions: Panel Size: 450mm X 150mm Nos 70.00 0
25.D.12 FLS82 - Fire Warning Wall Mount Sign panel to be fabricated using 1.5 mm thk MS sheet. Sign panel to be finished with photoluminiscent PU coating in specified color as per design intent. Thin MS mounting plate with anti-rust coating fixed onto wall using counter-sunk screws with plastic plug. Sign panel to be pasted on MS mounting plate using 3M VHB tape. Sign content and graphics to be printed on 3M clear view film as per sign type layout (master artworks) and pasted on sign panel as per vinyl manufacturers specifications. Braille content cut in 2mm thk PMMA to be pasted over sign panel as per design intent. Dimensions: Panel Size: 450mm X 150mm Nos 10.00 0
25.D.13 FLS83 - Fire Warning (Fire Lane) Post Mount Providing and fixing slimline/ economic aluminum display frame of approved finish and color, anchored to the mounting surface as per manufactures specifications . 1mm thk Rigid sign panel to be adequately fire rated and pasted on the display frame. Graphics to be UV printed on rigid sheet as per sign type layout. Aluminum frame and rigid sign panel to be of approved make (Prolite or equivalent). Dimensions: Panel Size: 400mm X 150mm Nos 5.00 0
25.D.14 FLS84 - Assembly Area Identification Post Mount Sign panel to be fabricated using 1.5 mm thk MS sheet. Sign panel to be finished with photoluminiscent PU coating in specified color as per design intent. Thin MS mounting plate with anti-rust coating fixed onto wall using counter-sunk screws with plastic plug. Sign panel to be pasted on MS mounting plate using 3M VHB tape. Sign content and graphics to be printed on 3M clear view film as per sign type layout (master artworks) and pasted on sign panel as per vinyl manufacturers specifications. Dimensions: Panel Size: 500mm X 600mm Nos 6.00 0
25.D.15 FLS85 - Push Bar Identification Door Mount Providing and pasting of 0.2mm thk self adhesive flexible photoluminescent based glow-in-the dark, adequately fire rated sheet with UV printed graphics as per sign type layout & braille content cut in 2mm thk PMMA to be pasted over sign panel. Photoluminescent sheet to be of approved rating with glow time of 6-8 hours. Dimensions: Panel Size: 400mm X 160mm Nos 31.00 0
25.D.16 FLS86 - Fire Action Wall Mount Sign panel to be fabricated using 1.5 mm thk MS sheet. Sign panel to be finished with photoluminiscent PU coating in specified color as per design intent. Thin MS mounting plate with anti-rust coating fixed onto wall using counter-sunk screws with plastic plug. Sign panel to be pasted on MS mounting plate using 3M VHB tape. Sign content and graphics to be printed on 3M clear view film as per sign type layout (master artworks) and pasted on sign panel as per vinyl manufacturers specifications. Braille content cut in 2mm thk PMMA to be pasted over sign panel as per design intent. Dimensions: Panel Size: 1600mm X 1100mm Nos 31.00 0
TOTAL OF SIGNAGE & WAYFINDING WORKS 0
26 SPECIAL LIGHTING
1. To be complied with all the conditions mentioned in the Luminaire tender Preface
2. All items supplied shall be of original manufacturer make. Certificates of authenticity, performance data sheets, and relevant compliance documents shall be furnished upon request
3. Samples of each item shall be submitted for review and approved by the designer prior to bulk supply.
4. Materials must be delivered in original, sealed, and labelled manufacturer packaging. All goods must be handled and stored at site in accordance with manufacturer’s recommendations to avoid damage.
26.1 Luminaires
26.1.1 BS01 : SITC of DALI dimmable, surface mounted linear LED strip with dotless opal diffuser, constructed from aluminium body/profile with factory-finished white appearance, complete in all respects. The fixture shall be suitable for installation as indicated on drawings, with length to suit installation, maximum width of 15mm, and maximum height of 8mm. The fixture shall use LED light source, 3000K, CRI 90, with diffused beam distribution, delivering minimum 1000lm/m, and maximum wattage of 10W/m. The driver shall be remote type and suitable for DALI control. IP rating of the luminaire shall be IP44. Warranty on the fixture shall be five years from the date of commissioning. The rate shall be inclusive of driver, mounting clips, end caps, connectors, aluminium extrusion, diffuser, all accessories, connections, hardware, packaging, transportation, and delivery to site in good condition. Samples of the luminaire, accessories, and manufacturer’s datasheets shall be submitted to the designer in charge for approval prior to bulk supply Rmt 670.50 0
26.1.2 BS02 : SITC of DALI dimmable, surface mounted linear LED strip with dotless opal diffuser, constructed from aluminium body/profile with factory-finished white appearance, complete in all respects. The fixture shall be suitable for installation as indicated on drawings, with length of 1000mm, maximum width of 50mm, and maximum height of 50mm. The fixture shall use LED light source, 3000K, CRI 90, with diffused beam distribution, delivering minimum 2000lm/m, and maximum wattage of 20W/m. The driver shall be integral type and suitable for DALI control. IP rating of the luminaire shall be IP44. Warranty on the fixture shall be five years from the date of commissioning. The rate shall be inclusive of driver, mounting clips, end caps, connectors, aluminium extrusion, diffuser, all accessories, connections, hardware, packaging, transportation, and delivery to site in good condition. Samples of the luminaire, accessories, and manufacturer’s datasheets shall be submitted to the designer in charge for approval prior to bulk supply. Rmt 1,442.60 0
26.1.3 BS03 : SITC of DALI dimmable, surface mounted linear LED strip with dotless opal diffuser, constructed from aluminium body/profile with factory-finished black appearance, complete in all respects. The fixture shall be suitable for installation as indicated on drawings, with length of 1000mm, maximum width of 20mm, and maximum height of 80mm. The fixture shall use LED light source, 3000K, CRI 90, with diffused beam distribution, delivering minimum 500lm/m, and maximum wattage of 5W/m. The driver shall be integral type and suitable for DALI control. IP rating of the luminaire shall be IP44. Warranty on the fixture shall be five years from the date of commissioning. The rate shall be inclusive of driver, mounting clips, end caps, connectors, aluminium extrusion, diffuser, all accessories, connections, hardware, packaging, transportation, and delivery to site in good condition. Samples of the luminaire, accessories, and manufacturer’s datasheets shall be submitted to the designer in charge for approval prior to bulk supply. Rmt 19.20 0
26.1.4 BS04 : SITC of DALI dimmable, ceiling suspended suspended linear ultra wide cellular downlight, constructed from aluminium body/profile with factory-finished white appearance, complete in all respects. The fixture shall be suitable for installation as indicated on drawings, with maximum length of 3000mm, maximum width of 50mm, and maximum height of 50mm. The fixture shall use LED light source, 3000K, CRI 90, with wide beam distribution, delivering minimum 2000lm/m, and maximum wattage of 20W/m. The driver shall be integral type and suitable for DALI control. IP rating of the luminaire shall be IP20. Warranty on the fixture shall be five years from the date of commissioning. The rate shall be inclusive of driver, mounting clips, end caps, connectors, aluminium extrusion, diffuser, all accessories, connections, hardware, packaging, transportation, and delivery to site in good condition. Samples of the luminaire, accessories, and manufacturer’s datasheets shall be submitted to the designer in charge for approval prior to bulk supply. Rmt 28.00 0
26.1.5 BS51 : SITC of remote type, surface mounted linear underwater flexible LED strip with dotless opal diffuser, constructed from aluminium body/profile with factory-finished black, complete in all respects. The fixture shall be suitable for installation as indicated on drawings, with length to suit installation, maximum width of 20mm, and maximum height of 10mm. The fixture shall use LED light source, 3000K, CRI 90, with diffused beam distribution, delivering minimum 1200 lm/m, and maximum wattage of 12W/m. The driver shall be remote type. IP rating of the luminaire shall be IP68. Warranty on the fixture shall be five years from the date of commissioning. The rate shall be inclusive of driver, mounting clips, end caps, connectors, aluminium extrusion, diffuser, all accessories, connections, hardware, packaging, transportation, and delivery to site in good condition. Samples of the luminaire, accessories, and manufacturer’s datasheets shall be submitted to the designer in charge for approval prior to bulk supply. Rmt 177.90 0
26.1.6 BS52 : SITC of remote type, surface mounted linear flexible LED strip with dotless opal diffuser, constructed from aluminium body/profile with factory-finished black, complete in all respects. The fixture shall be suitable for installation as indicated on drawings, with length to suit installation, maximum width of 20mm, and maximum height of 10mm. The fixture shall use LED light source, 3000K, CRI 90, with diffused beam distribution, delivering minimum 1200 lm/m, and maximum wattage of 12W/m. The driver shall be remote type. IP rating of the luminaire shall be IP65. Warranty on the fixture shall be five years from the date of commissioning. The rate shall be inclusive of driver, mounting clips, end caps, connectors, aluminium extrusion, diffuser, all accessories, connections, hardware, packaging, transportation, and delivery to site in good condition. Samples of the luminaire, accessories, and manufacturer’s datasheets shall be submitted to the designer in charge for approval prior to bulk supply. Rmt 190.70 0
26.1.7 DR01 : SITC of DALI dimmable, ceiling recessed round adjustable pinhole downlight, constructed from aluminium body/profile with factory-finished white appearance, complete in all respects. The fixture shall be suitable for installation as indicated on drawings, with maximum diameter of 80mm and maximum recessed depth of 100mm. The fixture shall use LED light source, 3000K, CRI 90, with medium beam distribution, delivering minimum 1000lm, and maximum wattage of 10W. The driver shall be integral type and suitable for DALI control. IP rating of the luminaire shall be IP44. Warranty on the fixture shall be five years from the date of commissioning. The rate shall be inclusive of driver, mounting clips, end caps, connectors, aluminium extrusion, diffuser, all accessories, connections, hardware, packaging, transportation, and delivery to site in good condition. Samples of the luminaire, accessories, and manufacturer’s datasheets shall be submitted to the designer in charge for approval prior to bulk supply. Nos 209.00 0
26.1.8 DR02 : SITC of DALI dimmable, ceiling recessed rectangular micro downlight, constructed from aluminium body/profile with factory-finished white appearance, complete in all respects. The fixture shall be suitable for installation as indicated on drawings, with maximum length of 150mm, maximum width of 40mm, and maximum height of 50mm. The fixture shall use LED light source, 3000K, CRI 90, with medium beam distribution, delivering minimum 1200lm, and maximum wattage of 12W. The driver shall be integral type and suitable for DALI control. IP rating of the luminaire shall be IP20. Warranty on the fixture shall be five years from the date of commissioning. The rate shall be inclusive of driver, mounting clips, end caps, connectors, aluminium extrusion, diffuser, all accessories, connections, hardware, packaging, transportation, and delivery to site in good condition. Samples of the luminaire, accessories, and manufacturer’s datasheets shall be submitted to the designer in charge for approval prior to bulk supply. Nos 290.00 0
26.1.9 DR04 : SITC of DALI dimmable, ceiling recessed rectangular light panel, constructed from aluminium body/profile with factory-finished white appearance, complete in all respects. The fixture shall be suitable for installation as indicated on drawings, with maximum length of 1200mm, maximum width of 300mm, and maximum height of 50mm. The fixture shall use LED light source, 3000K, CRI 90, with diffused beam distribution, delivering minimum 2400lm, and maximum wattage of 24W. The driver shall be integral type and suitable for DALI control. IP rating of the luminaire shall be IP20. Warranty on the fixture shall be five years from the date of commissioning. The rate shall be inclusive of driver, mounting clips, end caps, connectors, aluminium extrusion, diffuser, all accessories, connections, hardware, packaging, transportation, and delivery to site in good condition. Samples of the luminaire, accessories, and manufacturer’s datasheets shall be submitted to the designer in charge for approval prior to bulk supply. Nos 76.00 0
26.1.10 DR05 : SITC of DALI dimmable, ceiling recessed round adjustable pinhole downlight, constructed from aluminium body/profile with factory-finished white appearance, complete in all respects. The fixture shall be suitable for installation as indicated on drawings, with maximum diameter of 70mm and maximum recessed depth of 115mm. The fixture shall use LED light source, 3000K, CRI 90, with medium beam distribution, delivering minimum 1200lm, and maximum wattage of 12W. The driver shall be integral type and suitable for DALI control. IP rating of the luminaire shall be IP20. Warranty on the fixture shall be five years from the date of commissioning. The rate shall be inclusive of driver, mounting clips, end caps, connectors, aluminium extrusion, diffuser, all accessories, connections, hardware, packaging, transportation, and delivery to site in good condition. Samples of the luminaire, accessories, and manufacturer’s datasheets shall be submitted to the designer in charge for approval prior to bulk supply. Nos 78.00 0
26.1.11 DR06 : SITC of DALI dimmable, ceiling recessed round adjustable pinhole downlight, constructed from aluminium body/profile with factory-finished white appearance, complete in all respects. The fixture shall be suitable for installation as indicated on drawings, with maximum diameter of 60mm and maximum recessed depth of 100mm. The fixture shall use LED light source, 3000K, CRI 90, with medium beam distribution, delivering minimum 600lm, and maximum wattage of 6W. The driver shall be integral type and suitable for DALI control. IP rating of the luminaire shall be IP44. Warranty on the fixture shall be five years from the date of commissioning. The rate shall be inclusive of driver, mounting clips, end caps, connectors, aluminium extrusion, diffuser, all accessories, connections, hardware, packaging, transportation, and delivery to site in good condition. Samples of the luminaire, accessories, and manufacturer’s datasheets shall be submitted to the designer in charge for approval prior to bulk supply. Nos 166.00 0
26.1.12 DR07 : SITC of DALI dimmable, ceiling recessed rectangular light panel, constructed from aluminium body/profile with factory-finished white appearance, complete in all respects. The fixture shall be suitable for installation as indicated on drawings, with maximum length of 900mm, maximum width of 300mm, and maximum height of 50mm. The fixture shall use LED light source, 3000K, CRI 90, with diffused beam distribution, delivering minimum 2400lm, and maximum wattage of 24W. The driver shall be integral type and suitable for DALI control. IP rating of the luminaire shall be IP20. Warranty on the fixture shall be five years from the date of commissioning. The rate shall be inclusive of driver, mounting clips, end caps, connectors, aluminium extrusion, diffuser, all accessories, connections, hardware, packaging, transportation, and delivery to site in good condition. Samples of the luminaire, accessories, and manufacturer’s datasheets shall be submitted to the designer in charge for approval prior to bulk supply. Nos 6.00 0
26.1.13 DR08 : SITC of DALI dimmable, ceiling recessed round wall washer, constructed from aluminium body/profile with factory-finished white appearance, complete in all respects. The fixture shall be suitable for installation as indicated on drawings, with maximum diameter of 100mm and maximum recessed depth of 100mm. The fixture shall use LED light source, 3000K, CRI 90, with asymmetrical (ASYM) beam distribution, delivering minimum 1000lm, and maximum wattage of 10W. The driver shall be integral type and suitable for DALI control. IP rating of the luminaire shall be IP20. Warranty on the fixture shall be five years from the date of commissioning. The rate shall be inclusive of driver, mounting clips, end caps, connectors, aluminium extrusion, diffuser, all accessories, connections, hardware, packaging, transportation, and delivery to site in good condition. Samples of the luminaire, accessories, and manufacturer’s datasheets shall be submitted to the designer in charge for approval prior to bulk supply. Nos 45.00 0
26.1.14 DR09 : SITC of DALI dimmable, ceiling recessed linear downlight, constructed from aluminium body/profile with factory-finished white appearance, complete in all respects. The fixture shall be suitable for installation as indicated on drawings, with maximum length of 1000mm, maximum width of 50mm, and maximum height of 50mm. The fixture shall use LED light source, 3000K, CRI 90, with diffused beam distribution, delivering minimum 1000lm, and maximum wattage of 10W. The driver shall be integral type and suitable for DALI control. IP rating of the luminaire shall be IP20. Warranty on the fixture shall be five years from the date of commissioning. The rate shall be inclusive of driver, mounting clips, end caps, connectors, aluminium extrusion, diffuser, all accessories, connections, hardware, packaging, transportation, and delivery to site in good condition. Samples of the luminaire, accessories, and manufacturer’s datasheets shall be submitted to the designer in charge for approval prior to bulk supply. Nos 397.00 0
26.1.15 DR51 : SITC of integral type, ceiling recessed rectangular light panel, constructed from aluminium body/profile with factory-finished white, complete in all respects. The fixture shall be suitable for installation as indicated on drawings, with maximum length of 900mm, maximum width of 300mm, and maximum height of 50mm. The fixture shall use LED light source, 3000K, CRI 90, with diffused beam distribution, delivering minimum 2000lm, and maximum wattage of 20W. The driver shall be integral type. IP rating of the luminaire shall be IP65. Warranty on the fixture shall be five years from the date of commissioning. The rate shall be inclusive of driver, mounting clips, end caps, connectors, aluminium extrusion, diffuser, all accessories, connections, hardware, packaging, transportation, and delivery to site in good condition. Samples of the luminaire, accessories, and manufacturer’s datasheets shall be submitted to the designer in charge for approval prior to bulk supply. Nos 31.00 0
26.1.16 DR52 : SITC of integral type, ceiling recessed round adjustable downlight, constructed from aluminium body/profile with factory-finished black appearance, complete in all respects. The fixture shall be suitable for installation as indicated on drawings, with maximum diameter of 80mm and maximum height of 150mm. The fixture shall use LED light source, 3000K, CRI 90, with medium beam distribution, delivering minimum 1000lm, and maximum wattage of 10W. The driver shall be integral type. IP rating of the luminaire shall be IP65. Warranty on the fixture shall be five years from the date of commissioning. The rate shall be inclusive of driver, mounting clips, end caps, connectors, aluminium extrusion, diffuser, all accessories, connections, hardware, packaging, transportation, and delivery to site in good condition. Samples of the luminaire, accessories, and manufacturer’s datasheets shall be submitted to the designer in charge for approval prior to bulk supply. Nos 21.00 0
26.1.17 DS01 : SITC of DALI dimmable, ceiling mounted rectangular downlight, constructed from aluminium body/profile with factory-finished white appearance, complete in all respects. The fixture shall be suitable for installation as indicated on drawings, with maximum length of 1000mm, maximum width of 50mm, and maximum height of 50mm. The fixture shall use LED light source, 3000K, CRI 90, with medium beam distribution, delivering minimum 1200lm, and maximum wattage of 12W. The driver shall be integral type and suitable for DALI control. IP rating of the luminaire shall be IP20. Warranty on the fixture shall be five years from the date of commissioning. The rate shall be inclusive of driver, mounting clips, end caps, connectors, aluminium extrusion, diffuser, all accessories, connections, hardware, packaging, transportation, and delivery to site in good condition. Samples of the luminaire, accessories, and manufacturer’s datasheets shall be submitted to the designer in charge for approval prior to bulk supply. Nos 458.00 0
26.1.18 DS02 : SITC of DALI dimmable, ceiling mounted rectangular downlight, constructed from aluminium body/profile with factory-finished white appearance, complete in all respects. The fixture shall be suitable for installation as indicated on drawings, with maximum length of 500mm, maximum width of 50mm, and maximum height of 50mm. The fixture shall use LED light source, 3000K, CRI 90, with medium beam distribution, delivering minimum 600lm, and maximum wattage of 6W. The driver shall be integral type and suitable for DALI control. IP rating of the luminaire shall be IP20. Warranty on the fixture shall be five years from the date of commissioning. The rate shall be inclusive of driver, mounting clips, end caps, connectors, aluminium extrusion, diffuser, all accessories, connections, hardware, packaging, transportation, and delivery to site in good condition. Samples of the luminaire, accessories, and manufacturer’s datasheets shall be submitted to the designer in charge for approval prior to bulk supply. Nos 29.00 0
26.1.19 DS03 : SITC of DALI dimmable, ceiling suspended square shaped diffused light, constructed from aluminium body/profile with factory-finished white appearance, complete in all respects. The fixture shall be suitable for installation as indicated on drawings, with maximum length of 900mm, maximum width of 90mm, and maximum height of 50mm. The fixture shall use LED light source, 3000K, CRI 90, with medium beam distribution, delivering minimum 800lm, and maximum wattage of 8W. The driver shall be integral type and suitable for DALI control. IP rating of the luminaire shall be IP20. Warranty on the fixture shall be five years from the date of commissioning. The rate shall be inclusive of driver, mounting clips, end caps, connectors, aluminium extrusion, diffuser, all accessories, connections, hardware, packaging, transportation, and delivery to site in good condition. Samples of the luminaire, accessories, and manufacturer’s datasheets shall be submitted to the designer in charge for approval prior to bulk supply. Nos 8.00 0
26.1.20 DS51 : SITC of integral type, surface mounted round downlight, constructed from aluminium body/profile with factory-finished black, complete in all respects. The fixture shall be suitable for installation as indicated on drawings, with maximum diameter of 190mm and maximum height/depth of 155mm. The fixture shall use LED light source, 3000K, CRI 90, with medium beam distribution, delivering minimum 2400lm, and maximum wattage of 24W. The driver shall be integral type. IP rating of the luminaire shall be IP65. Warranty on the fixture shall be five years from the date of commissioning. The rate shall be inclusive of driver, mounting clips, end caps, connectors, aluminium extrusion, diffuser, all accessories, connections, hardware, packaging, transportation, and delivery to site in good condition. Samples of the luminaire, accessories, and manufacturer’s datasheets shall be submitted to the designer in charge for approval prior to bulk supply. Nos 17.00 0
26.1.21 DS52 : SITC of integral type, surface mounted rectangular downlight, constructed from aluminium body/profile with factory-finished black, complete in all respects. The fixture shall be suitable for installation as indicated on drawings, with maximum length of 150mm, maximum width of 50mm, and maximum height of 100mm. The fixture shall use LED light source, 3000K, CRI 90, with medium beam distribution, delivering minimum 1200lm, and maximum wattage of 12W. The driver shall be integral type. IP rating of the luminaire shall be IP65. Warranty on the fixture shall be five years from the date of commissioning. The rate shall be inclusive of driver, mounting clips, end caps, connectors, aluminium extrusion, diffuser, all accessories, connections, hardware, packaging, transportation, and delivery to site in good condition. Samples of the luminaire, accessories, and manufacturer’s datasheets shall be submitted to the designer in charge for approval prior to bulk supply. Nos 15.00 0
26.1.22 DS53 : SITC of integral type, surface mounted linear downlight, constructed from aluminium body/profile with factory-finished black, complete in all respects. The fixture shall be suitable for installation as indicated on drawings, with maximum length of 500mm, maximum width of 50mm, and maximum height of 100mm. The fixture shall use LED light source, 3000K, CRI 90, with medium beam distribution, delivering minimum 2000lm, and maximum wattage of 20W. The driver shall be integral type. IP rating of the luminaire shall be IP65. Warranty on the fixture shall be five years from the date of commissioning. The rate shall be inclusive of driver, mounting clips, end caps, connectors, aluminium extrusion, diffuser, all accessories, connections, hardware, packaging, transportation, and delivery to site in good condition. Samples of the luminaire, accessories, and manufacturer’s datasheets shall be submitted to the designer in charge for approval prior to bulk supply. Nos 12.00 0
26.1.23 FF51 : SITC of integral type, ground mounted post top luminaire, constructed from aluminium body/profile with factory-finished black, complete in all respects. The fixture shall be suitable for installation as indicated on drawings, with pole height of 4000mm, maximum width of 450mm, and maximum length of 250mm. The fixture shall use LED light source, 4000K, CRI 90, with wide beam distribution, delivering minimum 2600lm, and maximum wattage of 26W. The driver shall be integral type. IP rating of the luminaire shall be IP65. Warranty on the fixture shall be five years from the date of commissioning. The rate shall be inclusive of driver, mounting clips, end caps, connectors, aluminium extrusion, diffuser, all accessories, connections, hardware, packaging, transportation, and delivery to site in good condition. Samples of the luminaire, accessories, and manufacturer’s datasheets shall be submitted to the designer in charge for approval prior to bulk supply. Nos 89.00 0
26.1.24 FF52 : SITC of integral type, ground mounted bollard, constructed from aluminium body/profile with factory-finished black, complete in all respects. The fixture shall be suitable for installation as indicated on drawings, with maximum height of 1000mm and maximum footprint of 200mm x 200mm. The fixture shall use LED light source, 3000K, CRI 90, with wide beam distribution, delivering minimum 1200lm, and maximum wattage of 12W. The driver shall be integral type. IP rating of the luminaire shall be IP65. Warranty on the fixture shall be five years from the date of commissioning. The rate shall be inclusive of driver, mounting clips, end caps, connectors, aluminium extrusion, diffuser, all accessories, connections, hardware, packaging, transportation, and delivery to site in good condition. Samples of the luminaire, accessories, and manufacturer’s datasheets shall be submitted to the designer in charge for approval prior to bulk supply. Nos 81.00 0
26.1.25 FF53 : SITC of integral type, ground mounted stone lantern, constructed from aluminium body/profile with factory-finished black, complete in all respects. The fixture shall be suitable for installation as indicated on drawings, with maximum height of 1000mm and maximum length/width of 500mm. The fixture shall use LED light source, 3000K, CRI 90, with wide beam distribution, delivering minimum 800lm, and maximum wattage of 8W. The driver shall be integral type. IP rating of the luminaire shall be IP65. Warranty on the fixture shall be five years from the date of commissioning. The rate shall be inclusive of driver, mounting clips, end caps, connectors, aluminium extrusion, diffuser, all accessories, connections, hardware, packaging, transportation, and delivery to site in good condition. Samples of the luminaire, accessories, and manufacturer’s datasheets shall be submitted to the designer in charge for approval prior to bulk supply. Nos 8.00 0
26.1.26 FF54 : SITC of integral type, ground mounted stone niche light, constructed from aluminium body/profile with factory-finished black, complete in all respects. The fixture shall be suitable for installation as indicated on drawings, with maximum height of 1000mm and maximum length/width of 500mm. The fixture shall use LED light source, 3000K, CRI 90, with wide beam distribution, delivering minimum 800lm, and maximum wattage of 8W. The driver shall be integral type. IP rating of the luminaire shall be IP65. Warranty on the fixture shall be five years from the date of commissioning. The rate shall be inclusive of driver, mounting clips, end caps, connectors, aluminium extrusion, diffuser, all accessories, connections, hardware, packaging, transportation, and delivery to site in good condition. Samples of the luminaire, accessories, and manufacturer’s datasheets shall be submitted to the designer in charge for approval prior to bulk supply. Nos 12.00 0
26.1.27 FF55 : SITC of integral type, ground mounted post with spotlights, constructed from aluminium body/profile with factory-finished black, complete in all respects. The fixture shall be suitable for installation as indicated on drawings, with pole height of 4000mm, maximum diameter of 80mm, and maximum spotlight height of 100mm. The fixture shall use LED light source, 3000K, CRI 90, with wide beam distribution, delivering minimum 1200lm, and maximum wattage of 12W. The driver shall be integral type. IP rating of the luminaire shall be IP65. Warranty on the fixture shall be five years from the date of commissioning. The rate shall be inclusive of driver, mounting clips, end caps, connectors, aluminium extrusion, diffuser, all accessories, connections, hardware, packaging, transportation, and delivery to site in good condition. Samples of the luminaire, accessories, and manufacturer’s datasheets shall be submitted to the designer in charge for approval prior to bulk supply. Nos 2.00 0
26.1.28 HR01 : SITC of DALI dimmable, handrail recessed handrail integrated recessed luminaire, constructed from aluminium body/profile with factory-finished black appearance, complete in all respects. The fixture shall be suitable for installation as indicated on drawings, with maximum diameter of 30mm and maximum recessed height of 40mm. The fixture shall use LED light source, 3000K, CRI 90, with asymmetrical (ASYM) beam distribution, delivering minimum 120lm, and maximum wattage of 2W. The driver shall be integral type and suitable for DALI control. IP rating of the luminaire shall be IP44. Warranty on the fixture shall be five years from the date of commissioning. The rate shall be inclusive of driver, mounting clips, end caps, connectors, aluminium extrusion, diffuser, all accessories, connections, hardware, packaging, transportation, and delivery to site in good condition. Samples of the luminaire, accessories, and manufacturer’s datasheets shall be submitted to the designer in charge for approval prior to bulk supply. Nos 56.00 0
26.1.29 HR02 : SITC of DALI dimmable, handrail recessed handrail integrated recessed luminaire, constructed from aluminium body/profile with factory-finished black, complete in all respects. The fixture shall be suitable for installation as indicated on drawings, with maximum diameter of 30mm and maximum recessed height of 40mm. The fixture shall use LED light source, 3000K, CRI 90, with asymmetrical (ASYM) beam distribution, delivering minimum 120lm, and maximum wattage of 2W. The driver shall be integral type and suitable for DALI control. IP rating of the luminaire shall be IP67. Warranty on the fixture shall be five years from the date of commissioning. The rate shall be inclusive of driver, mounting clips, end caps, connectors, aluminium extrusion, diffuser, all accessories, connections, hardware, packaging, transportation, and delivery to site in good condition. Samples of the luminaire, accessories, and manufacturer’s datasheets shall be submitted to the designer in charge for approval prior to bulk supply. Nos 30.00 0
26.1.30 SS51 : SITC of remote type, mounting strap tree branch mounted round adjustable spotlight, constructed from aluminium body/profile with factory-finished black, complete in all respects. The fixture shall be suitable for installation as indicated on drawings, with maximum diameter of 100mm and maximum height of 150mm. The fixture shall use LED light source, 3000K, CRI 90, with medium beam distribution, delivering minimum 300lm, and maximum wattage of 6W. The driver shall be remote type. IP rating of the luminaire shall be IP65. Warranty on the fixture shall be five years from the date of commissioning. The rate shall be inclusive of driver, mounting clips, end caps, connectors, aluminium extrusion, diffuser, all accessories, connections, hardware, packaging, transportation, and delivery to site in good condition. Samples of the luminaire, accessories, and manufacturer’s datasheets shall be submitted to the designer in charge for approval prior to bulk supply. Nos 8.00 0
26.1.31 SS52 : SITC of remote type, ground mounted round adjustable spotlight, constructed from aluminium body/profile with factory-finished black, complete in all respects. The fixture shall be suitable for installation as indicated on drawings, with maximum diameter of 100mm and maximum height of 150mm. The fixture shall use LED light source, 3000K, CRI 90, with medium beam distribution, delivering minimum 800lm, and maximum wattage of 8W. The driver shall be remote type. IP rating of the luminaire shall be IP65. Warranty on the fixture shall be five years from the date of commissioning. The rate shall be inclusive of driver, mounting clips, end caps, connectors, aluminium extrusion, diffuser, all accessories, connections, hardware, packaging, transportation, and delivery to site in good condition. Samples of the luminaire, accessories, and manufacturer’s datasheets shall be submitted to the designer in charge for approval prior to bulk supply. Nos 20.00 0
26.1.32 SS53 : SITC of integral type, ground mounted floodlight, constructed from aluminium body/profile with factory-finished black, complete in all respects. The fixture shall be suitable for installation as indicated on drawings, with maximum diameter of 150mm and maximum height of 250mm. The fixture shall use LED light source, 3000K, CRI 90, with wide beam distribution, delivering minimum 3000lm, and maximum wattage of 13W. The driver shall be integral type. IP rating of the luminaire shall be IP65. Warranty on the fixture shall be five years from the date of commissioning. The rate shall be inclusive of driver, mounting clips, end caps, connectors, aluminium extrusion, diffuser, all accessories, connections, hardware, packaging, transportation, and delivery to site in good condition. Samples of the luminaire, accessories, and manufacturer’s datasheets shall be submitted to the designer in charge for approval prior to bulk supply. Nos 3.00 0
26.1.33 UR01 : SITC of remote type, floor recessed inground linear uplight with an opal diffuser, constructed from aluminium body/profile with factory-finished black appearance, complete in all respects. The fixture shall be suitable for installation as indicated on drawings, with length to suit installation, maximum width of 50mm, and maximum height of 50mm. The fixture shall use LED light source, 3000K, CRI 90, with wide beam distribution, delivering minimum 1000lm/m, and maximum wattage of 10W/m. The driver shall be remote type. IP rating of the luminaire shall be IP44. Warranty on the fixture shall be five years from the date of commissioning. The rate shall be inclusive of driver, mounting clips, end caps, connectors, aluminium extrusion, diffuser, all accessories, connections, hardware, packaging, transportation, and delivery to site in good condition. Samples of the luminaire, accessories, and manufacturer’s datasheets shall be submitted to the designer in charge for approval prior to bulk supply. Nos 122.90 0
26.1.34 UR51 : SITC of integral type, ground recessed inground linear wall washer, constructed from aluminium body/profile with factory-finished black, complete in all respects. The fixture shall be suitable for installation as indicated on drawings, with maximum length of 1000mm, maximum width of 60mm, and maximum recessed depth of 120mm. The fixture shall use LED light source, 3000K, CRI 90, with asymmetrical (ASYM) beam distribution, delivering minimum 2000lm, and maximum wattage of 20W. The driver shall be integral type. IP rating of the luminaire shall be IP65. Warranty on the fixture shall be five years from the date of commissioning. The rate shall be inclusive of driver, mounting clips, end caps, connectors, aluminium extrusion, diffuser, all accessories, connections, hardware, packaging, transportation, and delivery to site in good condition. Samples of the luminaire, accessories, and manufacturer’s datasheets shall be submitted to the designer in charge for approval prior to bulk supply. Nos 54.00 0
26.1.35 UR52 : SITC of integral type, ground recessed inground linear wall washer, constructed from aluminium body/profile with factory-finished black, complete in all respects. The fixture shall be suitable for installation as indicated on drawings, with maximum length of 500mm, maximum width of 60mm, and maximum recessed depth of 120mm. The fixture shall use LED light source, 3000K, CRI 90, with asymmetrical (ASYM) beam distribution, delivering minimum 1000lm, and maximum wattage of 10W. The driver shall be integral type. IP rating of the luminaire shall be IP65. Warranty on the fixture shall be five years from the date of commissioning. The rate shall be inclusive of driver, mounting clips, end caps, connectors, aluminium extrusion, diffuser, all accessories, connections, hardware, packaging, transportation, and delivery to site in good condition. Samples of the luminaire, accessories, and manufacturer’s datasheets shall be submitted to the designer in charge for approval prior to bulk supply. Nos 14.00 0
26.1.36 UR53 : SITC of integral type, ground recessed inground round uplight, constructed from aluminium body/profile with factory-finished black, complete in all respects. The fixture shall be suitable for installation as indicated on drawings, with maximum diameter of 80mm and maximum recessed depth of 120mm. The fixture shall use LED light source, 3000K, CRI 90, with medium beam distribution, delivering minimum 1000lm, and maximum wattage of 10W. The driver shall be integral type. IP rating of the luminaire shall be IP65. Warranty on the fixture shall be five years from the date of commissioning. The rate shall be inclusive of driver, mounting clips, end caps, connectors, aluminium extrusion, diffuser, all accessories, connections, hardware, packaging, transportation, and delivery to site in good condition. Samples of the luminaire, accessories, and manufacturer’s datasheets shall be submitted to the designer in charge for approval prior to bulk supply. Nos 59.00 0
26.1.37 UR54 : SITC of integral type, ground recessed inground square uplight, constructed from aluminium body/profile with factory-finished black, complete in all respects. The fixture shall be suitable for installation as indicated on drawings, with maximum dimensions of 200mm x 200mm and maximum recessed depth of 180mm. The fixture shall use LED light source, 3000K, CRI 90, with medium beam distribution, delivering minimum 1200lm, and maximum wattage of 12W. The driver shall be integral type. IP rating of the luminaire shall be IP65. Warranty on the fixture shall be five years from the date of commissioning. The rate shall be inclusive of driver, mounting clips, end caps, connectors, aluminium extrusion, diffuser, all accessories, connections, hardware, packaging, transportation, and delivery to site in good condition. Samples of the luminaire, accessories, and manufacturer’s datasheets shall be submitted to the designer in charge for approval prior to bulk supply. Nos 30.00 0
26.1.38 UR55 : SITC of integral type, ground recessed inground round uplight, constructed from aluminium body/profile with factory-finished black, complete in all respects. The fixture shall be suitable for installation as indicated on drawings, with maximum diameter of 100mm and maximum recessed depth of 120mm. The fixture shall use LED light source, 3000K, CRI 90, with medium beam distribution, delivering minimum 1200lm, and maximum wattage of 12W. The driver shall be integral type. IP rating of the luminaire shall be IP65. Warranty on the fixture shall be five years from the date of commissioning. The rate shall be inclusive of driver, mounting clips, end caps, connectors, aluminium extrusion, diffuser, all accessories, connections, hardware, packaging, transportation, and delivery to site in good condition. Samples of the luminaire, accessories, and manufacturer’s datasheets shall be submitted to the designer in charge for approval prior to bulk supply. Nos 11.00 0
26.1.39 UR56 : SITC of integral type, ground recessed inground water spout uplight, constructed from aluminium body/profile with factory-finished black, complete in all respects. The fixture shall be suitable for installation as indicated on drawings, with maximum diameter of 100mm and maximum recessed depth of 120mm. The fixture shall use LED light source, 3000K, CRI 90, with medium beam distribution, delivering minimum 1200lm, and maximum wattage of 12W. The driver shall be integral type. IP rating of the luminaire shall be IP68. Warranty on the fixture shall be five years from the date of commissioning. The rate shall be inclusive of driver, mounting clips, end caps, connectors, aluminium extrusion, diffuser, all accessories, connections, hardware, packaging, transportation, and delivery to site in good condition. Samples of the luminaire, accessories, and manufacturer’s datasheets shall be submitted to the designer in charge for approval prior to bulk supply. Nos 1.00 0
26.1.40 WR01 : SITC of DALI dimmable, wall recessed round step light, constructed from aluminium body/profile with factory-finished white appearance, complete in all respects. The fixture shall be suitable for installation as indicated on drawings, with maximum diameter of 150mm and maximum recessed depth of 100mm. The fixture shall use LED light source, 3000K, CRI 90, with asymmetrical (ASYM) beam distribution, delivering minimum 700lm, and maximum wattage of 7W. The driver shall be integral type and suitable for DALI control. IP rating of the luminaire shall be IP65. Warranty on the fixture shall be five years from the date of commissioning. The rate shall be inclusive of driver, mounting clips, end caps, connectors, aluminium extrusion, diffuser, all accessories, connections, hardware, packaging, transportation, and delivery to site in good condition. Samples of the luminaire, accessories, and manufacturer’s datasheets shall be submitted to the designer in charge for approval prior to bulk supply. Nos 6.00 0
26.1.41 WS01 : SITC of DALI dimmable, wall mounted rectangular luminaire with upward light only, constructed from aluminium body/profile with factory-finished white appearance, complete in all respects. The fixture shall be suitable for installation as indicated on drawings, with maximum length of 60mm, maximum width of 50mm, and maximum height of 50mm. The fixture shall use LED light source, 3000K, CRI 90, with wide beam distribution, delivering minimum 5000lm, and maximum wattage of 50W. The driver shall be integral type and suitable for DALI control. IP rating of the luminaire shall be IP44. Warranty on the fixture shall be five years from the date of commissioning. The rate shall be inclusive of driver, mounting clips, end caps, connectors, aluminium extrusion, diffuser, all accessories, connections, hardware, packaging, transportation, and delivery to site in good condition. Samples of the luminaire, accessories, and manufacturer’s datasheets shall be submitted to the designer in charge for approval prior to bulk supply. Nos 6.00 0
26.1.42 WS51 : SITC of integral type, wall mounted rectangular down light, constructed from aluminium body/profile with factory-finished grey, complete in all respects. The fixture shall be suitable for installation as indicated on drawings, with maximum length of 120mm, maximum depth of 160mm, and maximum height of 200mm. The fixture shall use LED light source, 3000K, CRI 90, with medium beam distribution, delivering minimum 2000lm, and maximum wattage of 20W. The driver shall be integral type. IP rating of the luminaire shall be IP65. Warranty on the fixture shall be five years from the date of commissioning. The rate shall be inclusive of driver, mounting clips, end caps, connectors, aluminium extrusion, diffuser, all accessories, connections, hardware, packaging, transportation, and delivery to site in good condition. Samples of the luminaire, accessories, and manufacturer’s datasheets shall be submitted to the designer in charge for approval prior to bulk supply. Nos 59.00 0
26.2 Luminaire Control System
Refer to "LDP_2545_Control Tender Package" for details
26.2.1 Supply, installation, programming, testing, and commissioning of a complete Lighting Control System (LCS) suitable for use in the public interior and exterior areas of a museum/ gallery or similar lighting environment, fully integrated with the lighting infrastructure and coordinated with other services comprising of: 1. hardware including, but not limited to: Lighting control modules, Keypads, dimmers, and control switches, Interface modules for DALI as mentioned in the drawings and documents 2. appropriate astronomical time clock, complete in all respects. The system shall be suitable for installation as indicated on drawings and programmed to ensure automated switching based on geographical coordinates. 3. appropriate day light sensors, complete in all respects The rate shall be inclusive of all accessories, connections, hardware, supports, packaging, transportation, installation and commissioning. Samples and manufacturer’s datasheets shall be submitted to the designer in charge for approval prior to bulk supply. Nos 1.00 0
26.2.2 Supply, installation, programming, testing, and commissioning of appropriate Key pad button panel, complete in all respects. The panel shall be suitable for installation as indicated on drawings, providing manual override and scene control functionality. The rate shall be inclusive of all accessories, connections, hardware, packaging, transportation, and delivery to site in good condition. Samples and manufacturer’s datasheets shall be submitted to the designer in charge for approval prior to bulk supply. Nos 26.00 0
26.2.3 Supply, installation, programming, testing, and commissioning of appropriate occupancy sensors, complete in all respects. Sensors shall be suitable for installation as indicated on drawings for automated energy-saving control. The rate shall be inclusive of all accessories, connections, hardware, packaging, transportation, and delivery to site in good condition. Samples and manufacturer’s datasheets shall be submitted to the designer in charge for approval prior to bulk supply. Nos 51.00 0
TOTAL OF SPECIAL LIGHTING 0
27. FURNITURE, FIXTURE & EQUIPMENT (FF&E)
Supply, packaging, crate logistics, transit insurance, safe local transportation, loading, unloading, internal horizontal and vertical shifting, assembly, leveling, and final placement of Furniture, Fixtures, and Equipment (FF&E) at designated Front of House (FOH) and Back of House (BOH) locations within the Museum premises, in pristine, showroom-quality condition.
The rate shall be comprehensive of all necessary high-tensile hardware, heavy-duty joinery fasteners, anchors, levelers, edge bandings, buffers, and specialized assembly tools. All fabrication and procurement must strictly align with the approved product reference selections, custom carpentry drawings, design intent, finishes, and material mock-ups verified by the Consultant/Client.
All items to have minimum 3 years comprehensive warranty against manufacturing defects, warping, or joint failures.
Metal elements to have Powder-coated CRCA steel or Stainless Steel (Grade 304) to prevent rusting.
Bins and tables in public zones must have high-impact resistance, anti-scratch coatings, and non-staining surfaces.
Public Space Durability (Heavy Duty): All hardware (hinges, drawer runners, locks) must be heavy-duty, commercial-grade (e.g., Hafele, Hettich, or equivalent) tested for high-frequency public use.
Defect Liability: Any item scratched, dented, or damaged during transit or installation will be rejected outright and must be replaced by the vendor at no extra cost.
Along with this document also read 'GVM - FF&E - Reference presentation' with visual reference images of the preferred selection.
All basic rates mentioned below are excluding GST
27.1.1 CF-01: Auditorium Folding chair, with reclining (Basic cost: Rs. 24,500) The SĀR AUDI seat and backrest are manufactured from CNC-machined moulded plywood shells with high-density moulded polyurethane (PU) foam to provide structural rigidity, long-term comfort and shape retention. The upholstery is in commercial-grade fabric, genuine leather or faux leather, as specified, fixed using concealed mechanical fastening. The supporting structure is fabricated from mild steel sections. All steel components are finished powder coating. The seat is mounted on a counterbalanced tip-up mechanism to provide silent automatic return. Armrests are manufactured in solid hardwood or upholstered PU, as specified. The product is mechanically assembled to facilitate maintenance, replacement of individual components and end-of-life material separation Nos 153.00 0
27.1.2 "CF-02: Leaning Bar at Auditorium & Bountiful Bridge (2.1 M wide) (Basic cost: Rs. 48,000) Supply and installation of LEANING BAR, designed by SĀR STUDIO. The leaning surface is manufactured from a CNC-machined solid plywood core with CNC-profiled high-density polyurethane (PU) foam. Side profiles are reinforced with Masonite (hardboard) to maintain profile stability and provide a uniform substrate for upholstery. The upholstery is in commercial-grade fabric, genuine leather or faux leather, as specified. The supporting frame is fabricated from mild steel tubular sections, fully welded and mechanically fixed to the floor. Steel components are finished powder coating, complete with concealed anchor fixings. The product is manufactured using a mechanical assembly system to facilitate maintenance, component replacement, repair and end-of-life material separation" Nos 6.00 0
27.1.3 "CF-03: Multi purpose - Trainer/ Tutor chair (Basic cost: Rs. 60,000)" Nos 6.00 0
27.1.4 "CF-04: Folding chair - Multi purpose - Audience/ Student chair (Basic cost: Rs. 15,000) Supply and installation of FOLDING CHAIR, designed by SĀR STUDIO, designed to fold into a compact profile for efficient storage, transport and handling. Shell: Load-bearing frame in matt epoxy powder-coated steelrod. Seat: Load-bearing seating structure made of steel, wovenwith high-tenacity polyester cord, solution-dyed,guaranteeing high resistance to atmospheric agents,light, and abrasions, with stretch resistance. Non-marking nylon glides are provided to protect finished floor surfaces " Nos 150.00 0
27.1.5 "CF-05: 3 seater Sofa - VIP Lounge & Baby feeding room (Basic cost: Rs. 96,000) Supply and installation of CONNECT Sofa, Medium, a multi-functional sofa designed by SĀR STUDIO. Modular three-seater sofa comprising independent seat modules with integrated upholstered armrests and backrests, made using 4 core materials: The solid construction is using an internal frame of 16 mm calibrated plywood reinforced with Nozag spring suspension system to provide structural rigidity, durability, and seating comfort. The exposed base/plinth is manufactured from solid Ash wood, finished in natural clear coat or approved pigmented stain, as specified. The seating and backrest are made in the form of a 'removable duvet' consisting of a combination of high-density and soft polyurethane (PU) foam, wrapped with polyester wadding to provide uniform comfort and maintain shape retention during prolonged use. The upholstery is made in genuine/faux leather or commercial-grade fabric, as specified, with removable tailored covers secured using concealed Velcro fastening for ease of maintenance and replacement. The product shall be manufactured using a mechanical assembly system to facilitate component replacement, repair, and end-of-life material separation, minimizing the use of permanent adhesives; designed for upcycling and recycling. DIMENSIONS : LENGTH : 230 cm / 90.5 in SEAT LENGTH : 180 cm / 70.8in WIDTH : 85 cm / 33.47 in SEAT WIDTH : 60 cm / 23.6 in HEIGHT : 73.5 cm / 28.9 in SEAT HEIGHT : 42.5 cm / 16.7 in " Nos 3.00 0
27.1.6 "CF-06: Chair at Restaurant, Café & South passage (Basic cost: Rs. 22,500) Supply and installation of Hoof Cantel Chair designed by SĀR STUDIO, comprising a solid wood frame with integrated seat and backrest assembly suitable for commercial, institutional, hospitality, and public-use environments. The chair is manufactured using a combination of solid wood, 16 mm calibrated plywood, and natural wood veneer. Exposed timber components are finished with a high-performance PU lacquer, providing resistance against stains, scratches, and normal wear associated with commercial use. The seat and backrest are designed as independent replaceable components, secured using proprietary mechanical SS hardware to facilitate maintenance and replacement without disturbing the primary structure. The chair is stackable up to four (4) units, enabling efficient storage and handling. The product is tested in accordance with ANSI/BIFMA X5.4:2020 for Strength, Durability, and Safety of Lounge and Public Seating. The item is supplied complete with all standard hardware and components, ready for installation and use DIMENSIONS: LENGTH - 62.5 cm / 24.60 in WIDTH - 58.5 cm / 23.03 in HEIGHT - 78 cm / 30.70 in SEATING HEIGHT - 45 cm / 17.71 in" Nos 99.00 0
27.1.7 "CF-07: Restaurant - 2 Seater bench (without backrest) (Basic cost: Rs. 62,000) Supply and installation of Hoof Bench – 2 Seater (Without Backrest), comprising a solid wood frame with upholstered or veneered seat assembly, suitable for restaurants, cafés, hospitality, institutional, and public-use environments. The bench is manufactured using a combination of solid wood, 16 mm calibrated plywood, and natural wood veneer. Exposed timber components are finished with a high-performance acrylic lacquer, providing resistance against stains, scratches, and normal wear associated with commercial use. The seat is available in upholstered fabric, genuine/faux leather, or natural wood veneer, and is designed as an independent replaceable component, secured using proprietary mechanical hardware to facilitate maintenance and replacement without disturbing the primary structure DIMENSIONS: LENGTH - 170 cm / 66.92 in WIDTH - 42 cm / 16.53 in HEIGHT - 46 cm / 18.11 in SEATING HEIGHT - 46 cm / 18.11 in " Nos 11.00 0
27.1.8 "CF-08: Restaurant long bench (with backrest) (Basic cost: Rs. 2,40,000) Supply and installation of Hoof Bench – Long Bench (With Backrest), custom designed by SĀR STUDIO, comprising a solid wood frame with upholstered or veneered seat assembly, suitable for restaurants, cafés, hospitality, institutional, and public-use environments. The bench is manufactured using a combination of solid Ash wood, 16 mm calibrated plywood, and natural wood veneer. Exposed timber components are finished with a high-performance acrylic lacquer, providing resistance against stains, scratches, and normal wear associated with commercial use. The seat is available in upholstered fabric, genuine/faux leather, or natural wood veneer, and is designed as an independent replaceable component, secured using proprietary mechanical hardware to facilitate maintenance and replacement without disturbing the primary structure DIMENSIONS: LENGTH - 480 cm / 188.97 in (as per drawing) WIDTH - 52 cm / 20.47 in BACK HEIGHT - 78 cm / 30.70 in SEATING HEIGHT - 46 cm / 18.11 in" Nos 2.00 0
27.1.9 "CF-09: Restaurant booth 2- seater with backrest (Basic cost: Rs. 39,800) Supply and installation of Hoof Booth – 2 Seater (With Backrest), Modular two-seater booth sofa comprising independent seat and backrests. The solid construction is using an internal frame of 16 mm calibrated plywood reinforced with Nozag spring suspension system to provide structural rigidity, durability, and seating comfort. Exposed timber components are finished with a high-performance acrylic lacquer, providing resistance against stains, scratches, and normal wear associated with commercial use. The seating and backrest are consisting of a combination of high-density and soft polyurethane (PU) foam, wrapped with polyester wadding. The upholstery is made in genuine leather or commercial-grade fabric, as specified, with removable tailored covers secured using concealed Velcro fastening for ease of maintenance and replacement. DIMENSIONS: LENGTH - 170 cm / 66.92 in WIDTH - 42 cm / 16.53 in HEIGHT - 78 cm / 30.70 in SEATING HEIGHT - 46 cm / 18.11 in " Nos 48.00 0
27.1.10 "CF-10: Restaurant outdoor dining chair (Basic cost: Rs. 22,500) Supply and installation of Cast - Outdoor armchair with aluminium casted frame and sling seat construction, custom designed by SĀR STUDIO The frame is fabricated in cast aluminium, designed for disassembly, compact packing, and replacement of individual components. All fasteners are in stainless steel or corrosion-resistant grade, suitable for sustained outdoor exposure. The frame finish is a powder-coat or anodized outdoor-grade finish, providing resistance against UV degradation, moisture, and corrosion. The seat and backrest are upholstered in a tensioned sling panel using 100% solution-dyed acrylic fabric, suitable for outdoor use, providing fade resistance, UV stability. The sling is secured around the frame tubes and is removable for cleaning or replacement." Nos 76.00 0
27.1.11 "CF-11: 3 Seater outdoor bench (Basic cost: Rs. 25,500) Supply and installation of sculptural bench in an I-beam profile form, custom designed by SĀR STUDIO cast in aluminium as a monolithic structural section. The bench is fabricated in aluminium, with an I-beam profile providing structural rigidity and a continuous seating surface. The base is anchored via an integrated foot plate, for floor mounted installation. The finish is natural silver, suitable for outdoor use." Nos 5.00 0
27.1.12 "CF-12: Baby care 3 seater sofa (Basic cost: Rs. 1,25,000) Supply and installation of Inner Paffe Sofa by SĀR STUDIO, comprising of a solid teak wood frame designed for disassembly, with mechanically jointed connections allowing for easy repair, part replacement, and maintenance without affecting the rest of the structure. The seating and backrest cushions consist of foam padding wrapped and contained within removable tailored covers, secured for ease of maintenance and replacement. The upholstery is made in fabric or faux leather, as specified, which is water and stain resistant, suitable for sustained use." Nos 2.00 0
27.1.13 "CF-13: South passage lobby single sofa (Basic cost: Rs. 38,900) Supply and installation of CONNECT Sofa, Small, a multi-functional sofa designed by SĀR STUDIO. Modular three-seater sofa comprising independent seat modules with integrated upholstered armrests and backrests, made using 4 core materials: The solid construction is using an internal frame of 16 mm calibrated plywood reinforced with Nozag spring suspension system to provide structural rigidity, durability, and seating comfort. The exposed base/plinth is manufactured from solid Ash wood, finished in natural clear coat or approved pigmented stain, as specified. The seating and backrest are made in the form of a 'removable duvet' consisting of a combination of high-density and soft polyurethane (PU) foam, wrapped with polyester wadding to provide uniform comfort and maintain shape retention during prolonged use. The upholstery is made in genuine/faux leather or commercial-grade fabric, as specified, with removable tailored covers secured using concealed Velcro fastening for ease of maintenance and replacement. The product shall be manufactured using a mechanical assembly system to facilitate component replacement, repair, and end-of-life material separation, minimizing the use of permanent adhesives; designed for upcycling and recycling." Nos 4.00 0
27.1.14 CF-14: Tunnel Bench with cushion 4.5 M wide (Basic cost: Rs. 1,80,000) Nos 3.00 0
27.1.15 "CF-15: Premium, Revolving conference chair - Vip Lounge (Basic cost: Rs. 67,500) Supply of Swivel Chair, custom designed by SAR Studio, The seat shell is constructed in moulded plywood, providing a contoured ergonomic base for the seating and backrest. The base is a swivel mechanism in metal, with height adjustment, mounted on a four-pronged star leg in a satin brushed finish. The seating and backrest are upholstered in medium-density foam, wrapped over the moulded shell and finished in leather, fabric, or faux leather, as specified." Nos 12.00 0
27.1.16 "CF-16: 2 seater sofa - VIP lounge, Lobby (Basic cost: Rs. 68,000) Supply and installation of CONNECT Sofa, Medium, a multi-functional sofa designed by SĀR STUDIO. Modular three-seater sofa comprising independent seat modules with integrated upholstered armrests and backrests, made using 4 core materials: The solid construction is using an internal frame of 16 mm calibrated plywood reinforced with Nozag spring suspension system to provide structural rigidity, durability, and seating comfort. The exposed base/plinth is manufactured from solid Ash wood, finished in natural clear coat or approved pigmented stain, as specified. The seating and backrest are made in the form of a 'removable duvet' consisting of a combination of high-density and soft polyurethane (PU) foam, wrapped with polyester wadding to provide uniform comfort and maintain shape retention during prolonged use. The upholstery is made in genuine/faux leather or commercial-grade fabric, as specified, with removable tailored covers secured using concealed Velcro fastening for ease of maintenance and replacement. The product shall be manufactured using a mechanical assembly system to facilitate component replacement, repair, and end-of-life material separation, minimizing the use of permanent adhesives; designed for upcycling and recycling." Nos 8.00 0
27.1.17 "CF-17: Lobby lounge chair (Basic cost: Rs. 38,900) Supply and installation of CONNECT Sofa, Small, a multi-functional sofa designed by SĀR STUDIO. Modular three-seater sofa comprising independent seat modules with integrated upholstered armrests and backrests, made using 4 core materials: The solid construction is using an internal frame of 16 mm calibrated plywood reinforced with Nozag spring suspension system to provide structural rigidity, durability, and seating comfort. The exposed base/plinth is manufactured from solid Ash wood, finished in natural clear coat or approved pigmented stain, as specified. The seating and backrest are made in the form of a 'removable duvet' consisting of a combination of high-density and soft polyurethane (PU) foam, wrapped with polyester wadding to provide uniform comfort and maintain shape retention during prolonged use. The upholstery is made in genuine/faux leather or commercial-grade fabric, as specified, with removable tailored covers secured using concealed Velcro fastening for ease of maintenance and replacement. The product shall be manufactured using a mechanical assembly system to facilitate component replacement, repair, and end-of-life material separation, minimizing the use of permanent adhesives; designed for upcycling and recycling." Nos 5.00 0
27.1.18 "CF-18: High chair - Ellipse cafe (Basic cost: Rs. 22,500) Supply and installation of Cantel high Chair designed by SĀR STUDIO, comprising a solid wood frame with integrated seat and backrest assembly suitable for commercial, institutional, hospitality, and public-use environments. The chair is manufactured using a combination of solid Ash wood, 16 mm calibrated plywood, and natural wood veneer. Exposed timber components are finished with a high-performance acrylic lacquer, providing resistance against stains, scratches, and normal wear associated with commercial use. The seat and backrest are designed as independent replaceable components, secured using proprietary mechanical SS hardware to facilitate maintenance and replacement without disturbing the primary structure. The product is tested in accordance with ANSI/BIFMA X5.4:2020 for Strength, Durability, and Safety of Lounge and Public Seating. The item is supplied complete with all standard hardware and components, ready for installation and use " Nos 7.00 0
27.1.19 "CF-19: Ellipse cafeteria 2 seater bench with cushion & backrest (Basic cost: Rs. 62,000) Supply and installation of Hoof Booth – 2 Seater (With Backrest), Modular two-seater booth sofa comprising independent seat and backrests. The solid construction is using an internal frame of 16 mm calibrated plywood reinforced with Nozag spring suspension system to provide structural rigidity, durability, and seating comfort. Exposed timber components are finished with a high-performance acrylic lacquer, providing resistance against stains, scratches, and normal wear associated with commercial use. The seating and backrest are consisting of a combination of high-density and soft polyurethane (PU) foam, wrapped with polyester wadding. The upholstery is made in genuine leather or commercial-grade fabric, as specified, with removable tailored covers secured using concealed Velcro fastening for ease of maintenance and replacement. DIMENSIONS: LENGTH - 170 cm / 66.92 in WIDTH - 42 cm / 16.53 in HEIGHT - 78 cm / 30.70 in SEATING HEIGHT - 46 cm / 18.11 in " Nos 23.00 0
27.1.20 "CF-20: Ellipse Outdoor Cafe - 4 Chair & Table set (Basic cost: Rs. 1,70,800) Supply and installation of Cast - Outdoor armchair with aluminium casted frame and sling seat construction. The frame is fabricated in cast aluminium, designed for disassembly, compact packing, and replacement of individual components. All fasteners are in stainless steel or corrosion-resistant grade, suitable for sustained outdoor exposure. The frame finish is a powder-coat or anodized outdoor-grade finish, providing resistance against UV degradation, moisture, and corrosion. The seat and backrest are upholstered in a tensioned sling panel using 100% solution-dyed acrylic fabric, suitable for outdoor use, providing fade resistance, UV stability. The sling is secured around the frame tubes and is removable for cleaning or replacement." Nos 21.00 0
27.2.1 "TF-01: Multipurpose - Tutor table (Basic cost: Rs. 28,000) Supply and installation of Flip-Top Table, custom designed by SĀR STUDIO The tabletop is constructed in 25mm thick pre-laminated board, available in plain colour or wood texture finish, with edge banding matching the colour of the countertop laminate. The top is designed to collapse to form a modesty panel below the work surface. The structure is fabricated in mild steel, finished to match the tutor chair, mounted on castors for mobility, with locking mechanism for stability when in use." Nos 2.00 0
27.2.2 "TF-02: Center table - Baby feeding room (Basic cost: Rs. 25,000) Supply and installation of Cradle center table, custom designed by SĀR STUDIO, comprising of a cast aluminium sculptural top The top is cast in aluminium in a sculptural draped form, lightweight in construction, mounted on cast aluminium legs. The table finish is satin brushed, in natural silver colour" Nos 1.00 0
27.2.3 "TF-03: Dining 4 seater table - Restaurant, South passage kiosk (Basic cost: Rs. 38,900) Supply and installation of island Café Table, custom designed by SĀR STUDIO. The table top is moulded in polyethylene. The column and base are fabricated in metal, finished in powder coat to the desired colour, designed for disassembly for ease of repair, part replacement, and maintenance. The base is a circular flat-plate design, providing stability, with the column mechanically fixed to the underside of the top. LENGTH - WIDTH - HEIGHT - " Nos 22.00 0
27.2.4 "TF-04: Dining 4 seater table - Restaurant, Café (Basic cost: Rs. 99,900) Supply and installation of CAP, 4 seater Dining Table, designed by SĀR STUDIO. The tabletop is constructed in coconut palm wood, dried prior to fabrication to ensure dimensional stability and resistance to warping. The surface is finished in a hardwax oil, providing resistance to stains, water, and everyday wear, with low-maintenance upkeep through occasional reapplication as required. The legs are fabricated in wood, with a concealed metal under structure, for stability and load distribution. The table is designed for indoor use, with all components assembled to allow ease of repair and part replacement as required." Nos 35.00 0
27.2.5 "TF-05: Dining 6 seater table - Restaurant (Basic cost: Rs. 1,25,000) Supply and installation of CAP, 4 seater Dining Table, designed by SĀR STUDIO. The tabletop is constructed in coconut palm wood, dried prior to fabrication to ensure dimensional stability and resistance to warping. The surface is finished in a hardwax oil, providing resistance to stains, water, and everyday wear, with low-maintenance upkeep through occasional reapplication as required. The legs are fabricated in wood, with a concealed metal under structure, for stability and load distribution. The table is designed for indoor use, with all components assembled to allow ease of repair and part replacement as required." Nos 6.00 0
27.2.6 "TF-06: Outdoor 4 seater dining table (Basic cost: Rs. 40,800) Supply and installation of Outdoor Table, custom designed by SĀR STUDIO. The base is cast in aluminium, with a central support column, fixed to the underside of the tabletop with mechanical fasteners. Finished UV-stable powder coat, suitable for sustained outdoor exposure. The tabletop is available in two options: (a) metal, powder coated or (b) thermo-treated ash wood slats, spaced for water drainage and finished for outdoor durability and dimensional stability. All components are designed for disassembly, allowing replacement of the top or base independently." Nos 19.00 0
27.2.7 "TF-07: Center table - VIP room & South passage lobby, kiosk (Basic cost: Rs. 20,400) Supply and installation of Coffee Table, custom designed by SĀR STUDIO. constructed in blockboard, with thick sections for table top and base. finished in veneer, available in ash, walnut, or smoked oak, as specified. Finish is PU matt lacquer, applied across all veneered surfaces for protection against everyday wear. All components are mechanically jointed for stability, with the base and top assembled to allow disassembly for repair or replacement." Nos 6.00 0
27.2.8 "TF-08: Multi functional - Conference/ Dining table 12 seater (Basic cost: Rs. 4,20,000) Supply and installation of 12-Seater Conference Table, custom designed by SĀR STUDIO. Structure is fabricated in MS sheet, minimum 3mm thickness, folded to form the table top, side returns, and base, with an internal MS reinforcement frame to support the span. Cable management is provided through flush-mounted, 4 recessed cable boxes along the table length, connected via an internal cable channel within the table structure. Finish is powder coated, in colour as specified, applied across all exposed MS surfaces. All structural joints are factory-welded and ground smooth." Nos 1.00 0
27.2.9 "TF-09: Long 7 seater high bar counter table - Elliptical building café (Basic cost: Rs. 2,00,000)" Nos 1.00 0
27.3.1 "SF-01: Restaurant cart storage in carpentry (Basic cost: Rs. 24,000) Supply and installation of cart storage, custom designed by SĀR STUDIO. The structure is constructed in 16mm calibrated plywood, with all internal and external surfaces finished in laminate, as per selection, matching the diner booth colour palette. All exposed edges are sealed with matching edge banding." Nos 4.00 0
27.3.2 "SF-02: Custom display shelves, storage (8.4 M long) - Souvenir shop (Basic cost: Rs. 4,00,000) Supply and installation of Display Cabinet, custom designed by SĀR Studio The carcass is constructed in solid wood, in natural finish or black pigmented stain, as specified. All exposed surfaces are finished in PU matt lacquer, providing resistance against scratches and everyday wear. The shutters are framed in solid wood, fitted with extra-clear toughened glass panels of minimum 6mm thickness, hung on custom-designed pivot hinges. The interior shelving is in toughened glass, height-adjustable, supported on metal shelf pins inserted into a pre-drilled hole series at regular intervals on the internal carcass walls. Hardware is in stainless steel or as specified, with finish consistent across pivot hinges and shelf pins." Nos 3.00 0
27.3.3 "SF-03: Custom shelves with both side display, storage (3.6 M)- Souvenir shop (Basic cost: Rs. 3,00,000) Supply and installation of Display Vitrine, custom designed by SĀR Studio The base is constructed in solid wood, finished in PU matt lacquer, available in natural finish or black pigmented stain, as specified. The superstructure is fabricated in mild steel, with thin-section framing to the shutters, finished in matt powder coat to match the base finish, as specified. The shutters are fitted with extra-clear toughened glass panels of minimum 6mm thickness, hung on custom-designed pivot hinges. The interior shelving is in toughened glass, height-adjustable, supported on metal shelf pins inserted into a pre-drilled hole series at regular intervals on the internal metal uprights. All hardware is in stainless steel or powder-coated metal, with finish consistent across pivot hinges and shelf pins." Nos 2.00 0
27.3.4 "SF-04: Custom display shelves, storage (1.2 M) - Souvenir shop (Basic cost: Rs. 75,000) Supply and installation of Display Cabinet, custom designed by SĀR Studio The carcass is constructed in solid wood, in natural finish or black pigmented stain, as specified. All exposed surfaces are finished in PU matt lacquer, providing resistance against scratches and everyday wear. The shutters are framed in solid wood, fitted with extra-clear toughened glass panels of minimum 6mm thickness, hung on custom-designed pivot hinges. The interior shelving is in toughened glass, height-adjustable, supported on metal shelf pins inserted into a pre-drilled hole series at regular intervals on the internal carcass walls. Hardware is in stainless steel or as specified, with finish consistent across pivot hinges and shelf pins." Nos 2.00 0
FOH: GARBAGE BIN
27.4.1 "GF-01: Public spaces - 3 in 1 multi waste garbage bin (Basic cost: Rs. 64,500) Supply and installation of WASTE SEGREGATION BIN, custom designed by SĀR STUDIO. The body is manufactured from laser-cut and CNC-folded Grade 304 stainless steel sheets, welded to form a rigid monocoque construction. The stainless steel is finished in a No. 4 satin brushed finish or architectural-grade powder coating, as specified. The top panel is provided with interchangeable laser-cut waste apertures and removable waste identification inserts for multiple waste streams. The unit is designed with a concealed front-access service door housing removable HDPE waste liners for ease of waste collection, cleaning and maintenance. All hardware is in Grade 304 stainless steel with concealed mechanical fixings. " Nos 22.00 0
27.4.2 "GF-02: Single bin - Restaurant seating (Basic cost: Rs. 28,000) Supply and installation of WASTE BIN, custom designed by SĀR STUDIO. The body is manufactured from laser-cut and CNC-folded Grade 304 stainless steel sheets, welded to form a rigid monocoque construction. The stainless steel is finished in a No. 4 satin brushed finish or architectural-grade powder coating, as specified. The top panel is provided with laser-cut waste aperture. The unit is designed with a concealed front-access service door housing removable HDPE waste liners for ease of waste collection, cleaning and maintenance. All hardware is in Grade 304 stainless steel with concealed mechanical fixings." Nos 2.00 0
27.4.3 "GF-03: Elliptical building - 3 in 1 multi waste garbage bin (Basic cost: Rs. 64,500) Supply and installation of WASTE SEGREGATION BIN, custom designed by SĀR STUDIO. The body is manufactured from laser-cut and CNC-folded Grade 304 stainless steel sheets, welded to form a rigid monocoque construction. The stainless steel is finished in a No. 4 satin brushed finish or architectural-grade powder coating, as specified. The top panel is provided with interchangeable laser-cut waste apertures and removable waste identification inserts for multiple waste streams. The unit is designed with a concealed front-access service door housing removable HDPE waste liners for ease of waste collection, cleaning and maintenance. All hardware is in Grade 304 stainless steel with concealed mechanical fixings." Nos 6.00 0
FOH: PATIENT BED
27.5.1 "PF-01: First Aid - cushioned bed,adjustable backrest (Basic cost: Rs. 25,000) Supply and installation of Patient bed, custom designed by SĀR Studio The carcass is constructed in 16mm pre-laminated board, with contrasting colour edge banding applied to all exposed edges. The internal frame is fabricated in mild steel, powder coated, providing structural support for the reclining backrest mechanism. The seating and backrest consist of a loose cushion mattress in medium-density foam wrapped with polyester wadding, with removable tailored covers in faux leather or fabric, as specified, secured for ease of removal, washing, and maintenance." Nos 1.00 0
27.6.1 "CB-01: Revolving chair with backrest - At Green rm,restaurant,reception, souvenir shop (Basic cost: Rs. 23,800) Supply and installation of REVOLVER CHAIR, custom designed by SĀR STUDIO. The chair is manufactured with its structural frame in molded plywood, supporting upholstered seat and back cushions in high-density polyurethane (PU) foam for comfort and durability. The upholstery is in commercial-grade fabric, genuine leather or faux leather, as specified. The base is manufactured from steel with a powder coating finish, complete with a 360° swivel return mechanism, as specified." Nos 17.00 0
27.6.2 "CB-02: Staff computer - revolving chair (Basic cost: Rs. 13,000) Supply and installation of Revolver Chair, bought out from specified brand. The chair is manufactured with its structural frame in moulded plywood, supporting independently upholstered seat and backrest cushions in high-density polyurethane (PU) foam for comfort and durability. The upholstery is in commercial-grade fabric, genuine leather, or faux leather, as specified. The base is in polished chrome-finished steel, mounted on castors, complete with a 360° swivel mechanism and pneumatic height adjustment. The armrests are in tubular polished chrome-finished steel, as specified." Nos 20.00 0
27.6.3 "CB-03: Executive doctor chair with revolving base, comfortable - First Aid room (Basic cost: Rs. 15,000) Supply and installation of Executive doctor chair, bought out as per specified brand. The chair is manufactured with its structural frame in moulded plywood, supporting an upholstered seat and mid-back backrest with lumbar support, padded in high-density polyurethane (PU) foam. The upholstery is in commercial-grade fabric, genuine leather, or faux leather, as specified. The base is in chrome-finished steel, mounted on castors, complete with a 360° swivel mechanism and pneumatic height adjustment. The armrests are non-adjustable, in chrome-finished steel with upholstered pads, as specified." Nos 2.00 0
27.6.4 "CB-04: First Aid patient chair with armrest (Basic cost: Rs. 14,500) Supply and installation of the Kiki chair, designed by SĀR STUDIO. The chair is handcrafted with its structural frame in reclaimed teak, ash, or beechwood, as specified, finished to the desired colour or stain. The seat and backrest are in form-pressed moulded plywood shells, upholstered in medium-density foam, finished in commercial-grade fabric, genuine leather, or faux leather, as specified." Nos 3.00 0
27.6.5 "CB-05: Cushioned service staff chair (Basic cost: Rs. 9,000) Supply and installation of dining chair, custom designed by SĀR STUDIO. The chair is fabricated entirely in aluminium, with legs in extruded aluminium sections and seat and backrest panels in pressed aluminium, finished in a satin brushed matt finish throughout. Floor glides in rubber or plastic are fitted at the base of each leg to protect the floor surface and prevent movement. OR Supply and installation of stack chair, designed by SĀR STUDIO. The chair is handcrafted from solid reclaimed teak/ ash wood, as specified, hand sanded and finished in PU matt/ PU high gloss, as specified. The seat and backrest are curved to provide ergonomic support. Structural connections are reinforced with industrially produced metal components, as specified." Nos 48.00 0
27.6.6 "CB-06: Locker room bench (3 seater) (Basic cost: Rs. 12,000) Supply and installation of bench, custom designed by SĀR STUDIO. The bench is fabricated entirely in aluminium, with legs in extruded aluminium sections and seat in pressed aluminium clad upon internal aluminium sections framework for laod distribution, finished in a satin brushed matt finish throughout. Floor glides in rubber or plastic are fitted at the base of each leg to protect the floor surface and prevent movement. OR Supply and installation of NEST bench, designed by SĀR Studio The bench is handcrafted from solid reclaimed teak or veneered ash, as specified, hand sanded and finished in PU matt or PU high gloss, as specified. Structural connections are reinforced with industrially produced metal components, with cross-bracing in metal rod." Nos 4.00 0
27.6.7 "CB-07: Staff working stool - industrial anti slip bush. (Basic cost: Rs. 13,600) Supply and installation of staff working stool, custom designed by SĀR STUDIO. The stool is fabricated entirely in aluminium, with legs in extruded aluminium sections and seat in pressed aluminium, finished in a satin brushed matt finish throughout. Floor glides in rubber or plastic are fitted at the base of each leg to protect the floor surface and prevent movement. OR Supply and installation of PROP stool, designed by SĀR Studio The stool is handcrafted from solid reclaimed teak or veneered ash, as specified, hand sanded and finished in PU matt or PU high gloss, as specified. Structural connections are reinforced with industrially produced metal components." Nos 13.00 0
27.6.8 "CB-08: Outdoor chair - Break garden (Basic cost: Rs. 19,800) Supply and installation of the Bloom chair, designed by SĀR Studio The frame is formed by bending industrial rebars, welded together to create a structural and sculptural form, finished in paint to the desired colour. The seat and backrest are in solid ash wood, CNC cut and hand sanded, finished in natural oil or lacquer as specified." Nos 8.00 0
27.6.9 CB-09: Outdoor bench - 3 seater (Basic cost: Rs. 25,500) Nos 2.00 0
27.6.10 "CB-10: Executive comfortable, revolving chair - Senior executive (Basic cost: Rs. 61,200) Supply and installation of High-Back Executive Chair, bought out. The chair is manufactured with its structural frame in moulded plywood, supporting an upholstered high-back floating backrest and seat in high-density polyurethane (PU) foam, shaped to body-hugging contours for ergonomic support. The upholstery is in commercial-grade fabric, faux leather, as specified. The base is in polished aluminium, mounted on hubless castors, complete with a 360° swivel mechanism and pneumatic height adjustment via easy-access adjustment buttons. The armrests are pivot-based, in polished aluminium with upholstered pads, as specified." Nos 2.00 0
27.6.11 "CB-11: Task chair, stackable, comfortable - Admin visitors chair (Basic cost: Rs. 34,000) The chair is handcrafted from solid reclaimed teak or ash, as specified, hand sanded and finished in PU matt or PU high gloss, as specified. The seat and backrest are curved to provide ergonomic support. Structural connections are reinforced with industrially produced metal components, as specified. A loose seat cushion in high-density polyurethane (PU) foam is provided, with a removable tailored cover in commercial-grade fabric, genuine leather, or faux leather, as specified, secured for ease of removal and maintenance." Nos 17.00 0
27.6.12 "CB-12: Executive comfortable, revolving chair - Curatorial executive (Basic cost: Rs. 53,500) Supply and installation of High-Back Executive Chair, bought out. The chair is manufactured with its structural frame in moulded plywood, supporting an upholstered high-back floating backrest and seat in high-density polyurethane (PU) foam, shaped to body-hugging contours for ergonomic support. The upholstery is in commercial-grade fabric, faux leather, as specified. The base is in polished aluminium, mounted on hubless castors, complete with a 360° swivel mechanism and pneumatic height adjustment via easy-access adjustment buttons. The armrests are pivot-based, in polished aluminium with upholstered pads, as specified." Nos 5.00 0
27.6.13 "CB-13: Premium, ergonomic, revolving chair - Admin Director (Basic cost: Rs. 85,000) Supply and installation of High-Back Executive Chair, bought out. The chair is manufactured with a single plywood back frame, upholstered in premium expanded polyurethane (EPU) with a seamlessly integrated headrest, providing cushioned contours and a luxurious finish. The upholstery cover is in commercial-grade fabric, genuine leather, or faux leather, as specified. The base is crown polished aluminium, mounted on 65mm castors without hoods, complete with a 360° swivel mechanism, pneumatic height adjustment, and knee tilt mechanism for postural adjustment. The armrests are fixed, with upholstered pads, as specified." Nos 1.00 0
27.6.14 "CB-14: Revolving, SS castor, with fixed arm rest - Conference chair (Basic cost: Rs. 42,400) Supply and installation of Medium-Back Executive Chair, bought out. The chair is manufactured with its structural frame in moulded plywood, supporting an upholstered medium-back seat and backrest in high-density polyurethane (PU) foam. The backrest is finished in leatherette and the seat in rexine. The armrests are non-adjustable, finished in wood veneer. The base is in chrome-finished steel, mounted on 60mm castors, complete with a 360° swivel mechanism, pneumatic height adjustment, and knee tilt mechanism for postural adjustment" Nos 24.00 0
27.6.15 "CB-15: 3 seater sofa - Admin Reception (Basic cost: Rs. 89,900) Supply and installation of CONNECT Sofa, Small, a multi-functional sofa designed by SĀR STUDIO. Modular three-seater sofa comprising independent seat modules with integrated upholstered armrests and backrests, made using 4 core materials: The solid construction is using an internal frame of 16 mm calibrated plywood reinforced with Nozag spring suspension system to provide structural rigidity, durability, and seating comfort. The exposed base/plinth is manufactured from solid Ash wood, finished in natural clear coat or approved pigmented stain, as specified. The seating and backrest are made in the form of a 'removable duvet' consisting of a combination of high-density and soft polyurethane (PU) foam, wrapped with polyester wadding to provide uniform comfort and maintain shape retention during prolonged use. The upholstery is made in genuine/faux leather or commercial-grade fabric, as specified, with removable tailored covers secured using concealed Velcro fastening for ease of maintenance and replacement. The product shall be manufactured using a mechanical assembly system to facilitate component replacement, repair, and end-of-life material separation, minimizing the use of permanent adhesives; designed for upcycling and recycling." Nos 1.00 0
27.6.16 "CB-16: Revolving, with arm rest chair - Admin meeting room (Basic cost: Rs. 42,400) Supply and installation of Medium-Back Executive Chair, bought out. The chair is manufactured with its structural frame in moulded plywood, supporting an upholstered medium-back seat and backrest in high-density polyurethane (PU) foam. The backrest is finished in leatherette and the seat in rexine. The armrests are non-adjustable, finished in wood veneer. The base is in chrome-finished steel, mounted on 60mm castors, complete with a 360° swivel mechanism, pneumatic height adjustment, and knee tilt mechanism for postural adjustment." Nos 6.00 0
27.6.17 "CB-17: Ergonomic, revolving chair - Admin workstations (Basic cost: Rs. 16,000) Supply and installation of ergonomic revolving chair, bought out. The chair is manufactured with a steel seat shell, upholstered in highly resilient cold-cure polyurethane foam, covered in 100% polyester fabric with a minimum 90% recycled content. The armrests are in powder-coated aluminium, fixed and non-adjustable. The base is a five-pronged star base in powder-coated aluminium, mounted on polypropylene castors with synthetic rubber treads, complete with a 360° swivel mechanism and lock mechanism in powder-coated steel." Nos 33.00 0
27.6.18 "CB-18: Comfortable, reclining chair - Admin docent lounge (Basic cost: RS. 53,500) The chair is manufactured with a moulded plywood seat shell, upholstered in high-resilience polyurethane foam, wrapped with polyester wadding, covered in commercial-grade woven textile. The base is a five-pronged star base in polished or brushed aluminium, mounted on hubless castors, complete with a 360° swivel mechanism, pneumatic height adjustment, and synchro-tilt mechanism with adjustable tension." Nos 8.00 0
27.6.19 "CB-19: Outdoor - High bar stool + Admin terrace (Basic cost: Rs. 10,000) Supply and installation of Bloom stool, designed by SĀR STUDIO. The frame is formed by bending industrial rebars, welded together to create a structural and sculptural form, finished in paint to the desired colour. The seat is in solid ash wood, CNC cut and hand sanded, finished in natural oil or lacquer as specified." Nos 16.00 0
27.6.20 "CB-20: 4 seater industrial bench - Ellipse basement lobby (Basic cost: Rs. 20,000)" Nos 2.00 0
27.7.1 "TB-01: Dresser table - Green room (1.2 m wide) (Basic cost: Rs. 23,400) Supply and installation of Wall-Mounted Side Credenza, custom designed by SĀR Studio The carcass is constructed in 16mm pre-laminated board, with matching edge banding applied to all exposed edges, wall-mounted with concealed metal brackets. The drawer is fitted with Hettich soft-close drawer channels. All hardware is in stainless steel or as specified. Supply and installation of Ceiling-Mounted Mirror, custom designed by SĀR Studio The mirror is 5mm, framed in mild steel finished in powder coat matt, with a pre-laminated backing panel, suspended from the ceiling on MS rods finished in matching powder coat matt. Blocking plywood in the ceiling to receive the suspension rods to be provided by the client's civil/interior team." Nos 9.00 0
27.7.2 TB-02: Audio controller Table (Basic cost: Rs. 27,000) Supply and installtion of Audio Controller Table, designed and manufactured as per technical drawing by Sar Studio. The structure of this retro table is fabricated in MS pipe sections, mechanically jointed, left natural or finished in powder coat to the desired colour. The carcass is constructed in one-sided pre-laminated board with matching edge banding on all exposed edges, housed within the MS pipe frame. The tabletop is in toughened glass, as specified, mechanically fixed to the MS frame. Cable management is provided through internal routing within the frame, with 4 flush-mounted recessed cable/power-data boxes integrated into the tabletop, connected via an internal cable channel within the structure. All drawer channels, hinges, and hardware are from Hettich, as specified. All audio and equipment systems are custom fitted as per selected models by the client, with equipment cutouts and cable routing coordinated to the selected equipment prior to fabrication. Nos 1.00 0
27.7.3 TB-03: Working desk with full storage (Basic cost: Rs. 75,000) Supply and installation of working Desk with storage, custom designed by SĀR STUDIO. The carcass is constructed in 16mm pre-laminated particle board, with matching edge banding applied to all four sides of all exposed edges. The storage unit is fitted with hinged shutters and adjustable internal shelving, supported on metal shelf pins. Cable management is provided through a flush-mounted recessed cable/power-data box integrated into the tabletop. All hinges and hardware are from Hettich, as specified. Nos 3.00 0
27.7.4 TB-04: Security desk without storage (Basic cost: Rs. 20,400) Supply and installation of work desk, custom designed by SĀR STUDIO. The table is fabricated entirely in mild steel, with a welded tubular leg frame and attached to the tabletop, finished in powder coat with a grainy texture, available in white, grey, or black, as specified. Table top is made with one-sided prelam board with edge banding on all four sides. Rubber or plastic bushes are fitted at the base of each leg to protect the floor surface and prevent movement. Nos 5.00 0
27.7.5 TB-05: Staff work desk without storage (Basic cost: Rs. 20,400) Supply and installation of work desk, custom designed by SĀR STUDIO. The table is fabricated entirely in mild steel, with a welded tubular leg frame and attached to the tabletop, finished in powder coat with a grainy texture, available in white, grey, or black, as specified. Table top is made with one-sided prelam board with edge banding on all four sides. Rubber or plastic bushes are fitted at the base of each leg to protect the floor surface and prevent movement. Nos 7.00 0
27.7.6 TB-06: Height adjustable computer table - Server/ BMS room (Basic cost: Rs. 45,000) Supply and installation of ergonomic Height adjustable computer table, bought out. The tabletop is minimum 20mm thick pre-laminated high-density particle board, finished with decorative laminate on the top surface and balancing laminate on the underside. All exposed edges are finished with 2mm thick PVC edge banding. Cable access grommets are provided at locations as indicated. The supporting frame is fabricated in mild steel, comprising telescopic lifting columns, cross members, and foot assemblies of adequate section thickness to ensure rigidity and stability. The height adjustment is operated by a synchronized crank-operated mechanical lifting system with telescopic steel columns, providing a smooth and stable height adjustment range of 680–1180 mm (±20 mm). Nos 6.00 0
27.7.7 TB-07: Work table without storage (Basic cost: Rs. 25,000) Supply and installation of work desk, custom designed by SĀR STUDIO. The table is fabricated entirely in mild steel, with a welded tubular leg frame and welded tabletop, finished in powder coat with a grainy texture, available in white, grey, or black, as specified. Rubber or nylon bushes are fitted at the base of each leg to protect the floor surface and prevent movement. Nos 13.00 0
27.7.8 TB-08: Working desk with storage (Basic cost: Rs. 42,500) Supply and installation of Executive Desk, custom designed by SĀR STUDIO. The carcass is constructed in 16mm pre-laminated particle board, with matching edge banding applied to all four sides of all exposed edges. The storage unit is fitted with hinged shutters and adjustable internal shelving, supported on metal shelf pins. Cable management is provided through a flush-mounted recessed cable/power-data box integrated into the tabletop. All hinges and hardware are from Hettich, as specified. Nos 5.00 0
27.7.9 TB-09: Side table without storage (Basic cost: Rs. 15,300) Supply and installation of work desk, custom designed by SĀR STUDIO. The table is fabricated entirely in mild steel, with a welded tubular leg frame and welded tabletop, finished in powder coat with a grainy texture, available in white, grey, or black, as specified. Rubber or nylon bushes are fitted at the base of each leg to protect the floor surface and prevent movement. Nos 5.00 0
27.7.10 TB-10: Writing table with storage (Basic cost: Rs. 28,000) Supply and installation of work desk, custom designed by SĀR STUDIO. The table is fabricated entirely in mild steel, with a welded tubular leg frame and welded tabletop, finished in powder coat with a grainy texture, available in white, grey, or black, as specified. Rubber or plastic bushes are fitted at the base of each leg to protect the floor surface and prevent movement. The pedestal storage unit is fabricated in mild steel, powder coated to match the desk finish, comprising one drawer fitted with soft-close drawer channels and one hinged shutter compartment, mounted on castors for mobility. The unit is suitable for attachment to the desk underframe or freestanding use, as specified. Nos 6.00 0
27.7.11 TB-11: MS industrial working table with storage & bush (Basic cost: Rs. 31,000) Supply and installation of Industrial Working Table with Storage, custom designed by SĀR STUDIO The frame is fabricated in mild steel or aluminium sections, as specified, designed for disassembly with exposed industrial bolts as a structural and detailing feature. The tabletop is constructed in 25mm particle board with contrasting colour edge banding applied to all four sides, mechanically fixed to the frame. The storage unit is fabricated in MS sheet, housing mechanically operated drawers, fixed to the underframe and finished to match the table. All components are fabricated for robust and durable use. Levelling gliders are fitted at the base of each leg to protect the floor surface and prevent movement. Nos 1.00 0
27.7.12 TB-12: MS industrial working table with storage (Basic cost: Rs. 1,05,000) Supply and installation of Industrial Working Table with Storage, custom designed by SĀR STUDIO The frame is fabricated in mild steel or aluminium sections, as specified, designed for disassembly with exposed industrial bolts as a structural and detailing feature. The tabletop is constructed in 25mm particle board with contrasting colour edge banding applied to all four sides, mechanically fixed to the frame. The storage unit is fabricated in MS sheet, housing mechanically operated drawers, fixed to the underframe and finished to match the table. All components are fabricated for robust and durable use. Levelling gliders are fitted at the base of each leg to protect the floor surface and prevent movement. Nos 3.00 0
27.7.13 TB-13: Working desk with drawer (Basic cost: 28,000) Supply and installation of Work Desk with Storage, custom designed by SĀR STUDIO The table is fabricated entirely in mild steel, with a welded tubular leg frame and welded tabletop, finished in powder coat with a grainy texture, available in white, grey, or black, as specified. Rubber or plastic bushes are fitted at the base of each leg to protect the floor surface and prevent movement. The storage unit is fabricated in mild steel, powder coated to match the desk finish, comprising three drawers fitted with Hettich soft-close drawer channels, with recessed pull handles, fixed to the underframe of the desk. Nos 2.00 0
27.7.14 TB-14: Outdoor Table - Admin break garden (Basic cost: Rs. 35,000) Supply and installation of Bloom Outdoor Table,designed by SĀR StUDIO The base is formed by bending 16mm torque steel, welded together to create a structural and sculptural frame, finished in powder coat to the desired colour. The central stem is in solid wood, available in natural or stained finish, sealed in acrylic matt lacquer, mechanically fixed to the rebar base and underside of the tabletop. The tabletop is in spun MS sheet metal, finished in powder coat to the desired colour, mechanically fixed to the stem. Designed for disassembly. Nos 2.00 0
27.7.15 TB-15: Executive table with storage - Admin senior & executive (Basic cost: Rs. 59,000) Supply and installation of working Desk with storage, custom designed by SĀR STUDIO. The carcass is constructed in 16mm pre-laminated particle board, with matching edge banding applied to all four sides of all exposed edges. The storage units on both ends of the desk are fitted with hinged shutters and adjustable internal shelving, supported on metal shelf pins. Cable management is provided through a flush-mounted recessed cable/power-data box integrated into the tabletop. All hinges and hardware are from Hettich, as specified. Nos 8.00 0
27.7.16 TB-16: Conference table 24 ppl with wire managers inbuilt (Basic cost: Rs. 4,20,000) Supply and installation of Conference Table, custom designed by SĀR Studio The 30mm tabletop is constructed with plywood composite and solid wood, finished with veneer or laminate as specified, with all exposed edges finished to match. The underside incorporates an internal cable management channel with flush-mounted recessed cable/power-data boxes integrated into the tabletop surface, connected via internal cable routing to the base. The legs are fabricated in cold-press moulded plywood, formed as per technical drawings, with internal metal support members as required for structural rigidity, finished in PU matt lacquer in natural or pigmented colour, as specified. Nos 1.00 0
27.7.17 TB-17: Admin workstation table/ clusters (Basic cost: Rs. 54,000) Supply and installation of Admin Workstation cluster table with Storage, custom designed by SĀR Studio The carcass is constructed in 16mm pre-laminated particle board, with matching edge banding applied to all four sides of all exposed edges. The storage unit is fitted with soft close hinged shutters and adjustable internal shelving, supported on metal shelf pins inserted into a pre-drilled hole series on the internal carcass walls. Cable management is provided through a flush-mounted recessed cable/power-data box integrated into the tabletop, with internal cable routing channelled to the base. The privacy screen panels above the tabletop are constructed with a plywood framework, upholstered in commercial-grade fabric on both faces, as specified, fixed to the tabletop on metal brackets. The workstation is designed for cluster configuration, with individual units joinable to form linear or grouped arrangements as per layout drawings. All hinges and hardware are from Hettich, as specified. Nos 40.00 0
27.7.18 TB-18: Admin center table (Basic cost: Rs. 37,000) Supply and installation of SLIDE center table, group of three, designed by SĀR STUDIO. The center table is handcrafted from blockboard and veneered ash, as specified, sanded and finished in PU matt in natural or pigmented colours, as specified, in natural, pigmented stain, or pigmented colour. Structural connections are reinforced with industrially produced metal components, as specified. Nos 1.00 0
27.7.19 TB-19: Outdoor - Standing bar table (Basic cost: Rs., 35,000) Supply and installation of Bloom Outdoor Table,designed by SĀR StUDIO The base is formed by bending 16mm torque steel, welded together to create a structural and sculptural frame, finished in powder coat to the desired colour. The central stem is in solid ash wood, available in natural or stained finish, sealed in acrylic matt lacquer, mechanically fixed to the rebar base and underside of the tabletop. The tabletop is in spun MS sheet metal, finished in powder coat to the desired colour, mechanically fixed to the stem. Designed for disassembly Nos 4.00 0
27.7.20 TB-20: Custom fabricated - L shaped bar counter with granite cladding - Admin Terrace (Basic cost: Rs. 75,000) The counter is constructed entirely in granite, fabricated and assembled as per technical drawings, with interlocking granite slabs forming the top surface and body of the counter. All slab-to-slab joints are bonded using a two-part epoxy or polyester adhesive formulated specifically for stone-to-stone bonding. All exposed edges and surfaces are finished as per specification. Joints between slabs are pointed with colour-matched epoxy grout and sealed with a stone-compatible sealant. Nos 1.00 0
27.8.1 SB-01: 3 door - full height cup board (2.1 M wide) at Green Room (Basic cost: Rs. 24,000) Supply and installation of Wardrobe, custom designed by SĀR STUDIO. The carcass is constructed in 16mm pre-laminated particleboard, with matching edge banding applied to all exposed edges, comprising side panels, bottom panel, back panel, internal shelving, and central partition. The back panel is constructed in a honeycomb-core composite board, pre-laminated on the face. The doors are in pre-laminated particleboard, hung on concealed soft-close hinges from Hettich, as specified. Internal fittings comprise a hanging rail in chrome-finished steel and fixed and adjustable shelving, supported on metal shelf pins inserted into a pre-drilled hole series on the internal carcass walls. The legs are fabricated in pre-laminated particleboard or MDF, mechanically fixed to the base of the carcass. All hinges, shelf pins, and hardware are from Hettich, as specified. Nos 3.00 0
27.8.2 SB-02: 1 x 1 M industrial - Control room rack (Basic cost: Rs. 42,000) Supply and installation of Storage Trolley, custom designed by SĀR Studio The frame is fabricated in mild steel tubular sections, welded and ground smooth at all joints, mounted on four castors with locking mechanism, finished in powder coat in silver grey or as specified. The shelves are in perforated mild steel sheet, mechanically fixed to the frame at each level, finished to match the frame. Nos 1.00 0
27.8.3 SB-03: 2 door full height storage with glass shutter for First AID (Basic cost: Rs. 32,000) Supply and installation of Full-Height Storage Cabinet, custom designed by SĀR STUDIO. The carcass is constructed in 16mm pre-laminated particleboard, with matching edge banding applied to all exposed edges, comprising side panels, top panel, bottom panel, back panel, internal shelving, and a fixed mid-height open shelf. The upper shutters are framed in MDF, fitted with toughened glass panels with CNC-routed MDF louvre overlay fixed to the glass face, hung on concealed soft-close hinges from Hettich, finished in paint to match the carcass. The lower shutters are in pre-laminated particleboard, hung on concealed soft-close hinges from Hettich, as specified. Internal shelving is adjustable, supported on metal shelf pins inserted into a pre-drilled hole series on the internal carcass walls. All hinges, shelf pins, and hardware are from Hettich, as specified. Nos 1.00 0
27.8.4 SB-04: First Aid low height cabinet storage (1.2 M wide) (Basic cost: Rs. 32,000) The carcass is constructed in 16mm pre-laminated particleboard, with matching edge banding applied to all exposed edges, comprising side panels, top panel, bottom panel, and back panel. The unit comprises multiple drawers fitted with soft-close drawer channels, with recessed pull handles finished to match the carcass. The unit is mounted on castors for mobility, with locking mechanism as specified. All drawer channels, hardware, and fittings are from Hettich, as specified. Nos 1.00 0
27.8.5 SB-05: Wall mounting chair storage - Multi purpose storage (Basic cost: Rs. 75,000) Supply and installation of Chair Storage Trolley, custom designed by SĀR STUDIO. The frame is fabricated in mild steel sheet and plate sections, welded and ground smooth at all joints, with horizontal shelf panels in mild steel sheet and vertical pin rod dividers at regular intervals on each shelf level for individual chair slot separation, fabricated as per technical drawings. The unit is mounted on four castors with locking mechanism for mobility, finished in powder coat to the desired colour. Nos 2.00 0
27.8.6 SB-06: Counter height storage runner - Restaurant & Souvenir (Basic cost: Rs. 24,000) The carcass is constructed in 16mm pre-laminated particleboard, with matching edge banding applied to all exposed edges, comprising side panels, top panel, bottom panel, and back panel. The unit comprises multiple drawers fitted with soft-close drawer channels, with recessed pull handles finished to match the carcass. The unit is mounted on castors for mobility, with locking mechanism as specified. All drawer channels, hardware, and fittings are from Hettich, as specified. Nos 3.00 0
27.8.7 SB-07: Custom 4.8 M long x .45 M wide custom fabricated - Wheelchair storage (Basic cost: Rs. 1,00,000) Supply and installation of Wheelchair Storage Trolley, custom designed by SĀR STUDIO. The frame is fabricated in mild steel sheet and plate sections, welded and ground smooth at all joints, with horizontal shelf panels in mild steel sheet and vertical pin rod dividers at regular intervals on each shelf level for individual wheelchair slot separation, fabricated as per technical drawings, and finished in powder coat to the desired colour. Nos 1.00 0
27.8.8 SB-08: 2 door - metal storage full height - Security locker rm, First Aid, Filing & storage rm (Basic cost: Rs. 20,000) The carcass is fabricated in aluminium sheet and plate sections, welded and ground smooth at all joints. The unit comprises two full-height hinged shutters, hung on heavy-duty aluminium-compatible hinges, with fixed internal shelving in aluminium sheet. Finished in natural silver or anodised / powder coated to the desired colour throughout. Nos 8.00 0
27.8.9 SB-09: Modular metal lockers with individual keys - For Ticketting, Locker rooms (Basic cost: Rs. 20,000) Supply and installation of Modular Metal Lockers, custom designed by SĀR Studio The frame is fabricated in mild steel sheet and plate sections, welded and ground smooth at all joints, designed for modular assembly allowing configuration as per layout drawings. Each locker unit is fitted with an individual hinged door in mild steel sheet, with a key lock and recessed handle. The frame structure incorporates contrasting colour edge detailing as specified. The unit is supported on mild steel legs, finished in powder coat to the desired colour throughout. Nos 34.00 0
27.8.10 SB-10: Network storage rack, as per ELV/ICT specs - for Server, BMS, AV, IT, BMS Rm (Basic cost: Rs. 30,000) Supply and installation of Network Storage Rack, custom designed by SĀR Studio The rack enclosure is fabricated in mild steel sheet, powder coated, with a perforated front door for airflow, hung on a full-length piano hinge and fitted with a three-point locking mechanism. The enclosure incorporates a contrasting colour edge detail as specified, consistent with the Industrial Series finish. The enclosure is sized and configured as per ELV/ICT consultant drawings, comprising adjustable 19-inch EIA-310 compliant mounting rails, internal cable management channels, vented top panel with cable entry, and levelling feet. Capacity, U-height, and depth to be confirmed by the ELV/ICT consultant prior to fabrication. Nos 23.00 0
27.8.11 SB-11: Cabin height storage - Staff break room (Basic cost: Rs. 24,000) Supply and installation of Cabin Height Metal Storage, custom designed by SĀR Studio The carcass is fabricated in aluminium sheet and plate sections, welded and ground smooth at all joints. The unit comprises four hinged shutters, hung on heavy-duty aluminium-compatible hinges, with fixed internal shelving in aluminium sheet. The unit is supported on a welded aluminium plinth base, finished in powder coat to the desired colour throughout. Nos 1.00 0
27.8.12 SB-12: Heavy Duty storage - Collection Room (Basic cost: Rs. 17,000) Supply and installation of Heavy Duty Storage Rack, custom designed by SĀR Studio. The frame is constructed in mild steel slotted angle sections, bolted together using zinc-plated nuts and bolts, with no welding, allowing for disassembly, reconfiguration, and adjustment of shelf heights at regular slotted intervals. Shelf panels are in mild steel sheet, mechanically fixed to the angle frame. The structure incorporates contrasting colour connecting hardware and edge detailing as specified. Finished in powder coat to the desired colour throughout. Nos 48.00 0
27.8.13 SB-13: Side runners with storage 750 MM high - Admin cabin (1.65 M wide average) (Basic cost: Rs. 22,000) Supply and installation of Modular Side Runner with Storage, custom designed by SĀR Studio The carcass is constructed in 16mm pre-laminated particleboard, with matching edge banding applied to all exposed edges. The unit comprises multiple hinged shutters with adjustable internal shelving, supported on metal shelf pins inserted into a pre-drilled hole series on the internal carcass walls. The unit is supported on a matching pre-laminated plinth base. All hinges and hardware are from Hettich, as specified. Nos 8.00 0
27.8.14 SB-14: Rear runners with storage 750 MM high - Admin cabin (2.70 M wide average) (Basic cost: Rs. 35,000) Supply and installation of Modular Side Runner with Storage, custom designed by SĀR Studio The carcass is constructed in 16mm pre-laminated particleboard, with matching edge banding applied to all exposed edges. The unit comprises multiple hinged shutters with adjustable internal shelving, supported on metal shelf pins inserted into a pre-drilled hole series on the internal carcass walls. The unit is supported on a matching pre-laminated plinth base. All hinges and hardware are from Hettich, as specified. Nos 10.00 0
27.8.15 SB-15: Side runner with integrated pantry counter & heating induction base - 900 MM high with storage - Admin conference table (3.7 M wide) (Basic cost: Rs. 2,20,000) Supply and installation of Side Runner with Integrated Pantry Counter, custom designed by SĀR Studio The carcass is constructed in 18mm marine plywood, finished with pre-laminated surface on all exposed faces, with matching edge banding applied to all exposed edges. The unit comprises multiple hinged shutters with fixed internal shelving. The unit is supported on a matching pre-laminated plinth base. All hinges and hardware are from Hettich, as specified. The countertop is in granite, as per selection, with cutouts provided for undermount sink, faucet, and induction cooking base, all supplied by the client. Nos 1.00 0
27.8.16 SB-16: Side runner storage 450 mm deep, 900 mm high (5.1 M long) Admin conference side storage (Basic cost: Rs. 1,80,000) Supply and installation of Side Runner Storage, custom designed by SĀR Studio The carcass is constructed in 16mm pre-laminated particleboard, with matching edge banding applied to all exposed edges. The unit comprises multiple hinged shutters with fixed internal shelving. The unit is supported on a matching pre-laminated plinth base. All hinges and hardware are from Hettich, as specified. Nos 1.00 0
27.8.17 SB-17: Custom fabricated - Display Shelf in 6 MM thick SS 304 grade - 1.5 M wide, 0.45 M deep, 1.2 M high (Basic cost: Rs. 85,000) A premium wall-mounted modular display and storage system comprising vertical powder-coated MS steel uprights with adjustable shelf brackets, open display shelves, inclined magazine display shelves, and integrated drawer storage. Shelves and cabinets shall be manufactured from 18 mm thick BWP grade plywood finished with high-pressure laminate/wood veneer and matching edge banding. Drawer units incorporate full-extension soft-close telescopic channels with concealed hardware. Steel components shall have a minimum 60–80 micron powder-coated finish. Unit shall include concealed wall fixing brackets, corrosion-resistant hardware, and a load-bearing capacity suitable for books and display materials. Overall dimensions and shelf configuration shall be as per approved drawings and site requirements Nos 1.00 0
27.8.18 SB-18: Compactor storage 4 bay - Admin File room (Basic cost: Rs. 8,05,000) Supply and installation of Compactor Storage, bought out The unit comprises 4 bays of fixed high-density shelving in mild steel sheet, powder coated, with internal shelving for file and document storage, floor-mounted or fixed to the wall or ceiling structure for stability as per site conditions. Capacity, bay width, and shelf configuration to be confirmed as per site dimensions and storage consultant specifications prior to procurement. Nos 1.00 0
27.8.19 SB-19: Compactor storage 6 bay - Admin File room (Basic cost: Rs. 12,00,000) Supply and installation of Compactor Storage, bought out The unit comprises 4 bays of fixed high-density shelving in mild steel sheet, powder coated, with internal shelving for file and document storage, floor-mounted or fixed to the wall or ceiling structure for stability as per site conditions. Capacity, bay width, and shelf configuration to be confirmed as per site dimensions and storage consultant specifications prior to procurement. Nos 1.00 0
27.8.20 SB-20: Side runner with storage 450 mm deep, 900 mm high (1.0 M) (Basic cost: Rs. 21,000) Supply and installation of Side Runner Storage, custom designed by SĀR Studio The carcass is constructed in 16mm pre-laminated particleboard, with matching edge banding applied to all exposed edges. The unit comprises multiple hinged shutters with fixed internal shelving. The unit is supported on a matching pre-laminated plinth base. All hinges and hardware are from Hettich, as specified. Nos 13.00 0
BOH: GARBAGE BIN
27.9.1 GB-01: 3 in 1 multi waste garbage bin - Staff lobby, BOH Passages (Basic cost: Rs. 54,000) Supply and installation of WASTE SEGREGATION BIN, custom designed by SĀR STUDIO. The body is manufactured from laser-cut and CNC-folded Grade 304 stainless steel sheets, welded to form a rigid monocoque construction. The stainless steel is finished in a No. 4 satin brushed finish or architectural-grade powder coating, as specified. The top panel is provided with interchangeable laser-cut waste apertures and removable waste identification inserts for multiple waste streams. The unit is designed with a concealed front-access service door housing removable HDPE waste liners for ease of waste collection, cleaning and maintenance. All hardware is in Grade 304 stainless steel with concealed mechanical fixings. Nos 5.00 0
27.9.2 GB-02: Waste management Bins (Basic cost: Rs. 18,000) Supply and installation of WASTE BIN, custom designed by SĀR STUDIO. The body is manufactured from laser-cut and CNC-folded Grade 304 stainless steel sheets, welded to form a rigid monocoque construction. The stainless steel is finished in a No. 4 satin brushed finish or architectural-grade powder coating, as specified. The top panel is provided with laser-cut waste aperture. The unit is designed with a concealed front-access service door housing removable HDPE waste liners for ease of waste collection, cleaning and maintenance. All hardware is in Grade 304 stainless steel with concealed mechanical fixings. Nos 12.00 0
BOH: PATIENT BED
27.10.1 PB-01: Industrial first aid bed, standard height (Basic cost: Rs. 35,000) Supply and installation of Patient bed, produced as per custom design by SĀR Studio The carcass is constructed in 16mm pre-laminated board, with contrasting colour edge banding applied to all exposed edges. The internal frame is fabricated in mild steel, powder coated, providing structural support for the reclining backrest mechanism. The seating and backrest consist of a loose cushion mattress in medium-density foam wrapped with polyester wadding, with removable tailored covers in faux leather or fabric, as specified, secured for ease of removal, washing, and maintenance. Nos 1.00 0
MOBILE CHARGING STATION
27.11 MC-01: Floor standing,With surge protection, In custom finish, Industrial built for Public spaces (Basic cost: Rs. 40,000) Industrial-grade floor-standing mobile charging station designed for continuous use in public spaces such as libraries, airports, educational institutions, transport terminals, and government buildings. Fabricated from minimum 1.6–2.0 mm CRCA/MS sheet with welded construction and durable powder-coated finish in approved custom colour. Unit shall incorporate multiple USB charging ports with integrated surge protection, over-current, over-voltage and short-circuit protection. Ventilated enclosure for heat dissipation, heavy-duty base for stability, concealed cable management, tamper-resistant hardware, and provision for floor anchoring. Includes utility shelves for device placement and storage. All electrical components shall comply with applicable IS/IEC safety standards. Overall dimensions, charging capacity, and finish shall be as per approved drawings and project requirements. Nos 7.00 0
PIN-UP/ NOTICE BOARD
27.12 NB-01: Cork pin up board with approved fabric minimum 15 MM thick - VIP & Admin office reception (3 M wide x 1.2 M height) (Basic cost: Rs. 15,000) Wall-mounted modular notice board manufactured from 9–12 mm thick high-density acoustic polyester fibre panels with concealed fixing system. Suitable for pinning notices while providing sound absorption. Finished in durable fabric/polyester surface, with moisture-resistant, fire-retardant, and low-maintenance properties. Complete with concealed wall mounting hardware and available in approved custom colours and sizes. Overall dimensions shall be as per approved drawings and project requirements Nos 2.00 0
27.13 MR-01: Modular design in nature, with premium materials & finishes - VIP Room Display Rack (Basic cost: Rs. 2,50,000) A premium wall-mounted modular display and storage system comprising vertical powder-coated MS steel uprights with adjustable shelf brackets, open display shelves, inclined magazine display shelves, and integrated drawer storage. Shelves and cabinets shall be manufactured from 18 mm thick BWP grade plywood finished with high-pressure laminate/wood veneer and matching edge banding. Drawer units incorporate full-extension soft-close telescopic channels with concealed hardware. Steel components shall have a minimum 60–80 micron powder-coated finish. Unit shall include concealed wall fixing brackets, corrosion-resistant hardware, and a load-bearing capacity suitable for books and display materials. Overall dimensions and shelf configuration shall be as per approved drawings and site requirements Nos 1.00 0
TOTAL OF FURNITURE, FIXTURE & EQUIPMENT (FF&E) 0
27. INTERIM MAINTENANCE PERIOD
27.1 Providing maintenance for the interim maintenance period as per RFP document per month 12.00 0
TOTAL OF INTERIM MAINTENANCE PERIOD 0
SuPr ENGINEERING CONSULTANTS 307, SIDDHARTH UPSCALE, VASNA ROAD VADODARA-390007 RATE ANALYSIS
VADODARA PROJECT : GVM
DATE :- 30.05.26 ARCHITECT : OPOLIS
SR.NO. NDSR Item No. BOQ ITEM NO. PARTICULARS CPWD / QUOTE REF. UNIT QTY RATE AMOUNT
1) Rate in Estimate are considered with following priority of rates as per availability:
a) Government of Gujarat: Road and Building Department: Schedule of Rate for Building Works Ahmedabad City (Without GST)
b) Central Public Works Department (CPWD) Delhi Schedule of Rates (DSR) Volume-1 & 2 for Civil Works Year 2023
Rates of CPWD DSR are inclusive of GST 18%. To arrive at Rate without GST, multiplying factor of 84.90%
c) Market quotes for Rates
d) Rate Analysis for items and derived rates from above.
RA-2 Providing and laying in position Ready Mixed M-40 grade concrete for reinforced cement conctere work , using cement content as per approved Design Mix manufactured in fully automatic batching plant and transported to site of work in transit mixer for a lead up to 10 kms having continuous agitated mixer, manufactured as per mix design of specified grade for reinforced cement concrete work including pumping of R.M.C. from transit mixer to site of laying, excluding the cost of centering shuttering finishing and reinforcement including cost of admixtures in recommended proportions as per IS: 9103 to accelerate/ retard setting of concrete, improve workability without impairing strength and durability as per direction of the Engineer - in - charge. Without Fly Ash (Min cement level as per latest IS 456 shall be maintained) (Cement level 575 kg )
5.33.2.5 Rate Analysis for 1 Cum 1.00 Sqm
Stone aggregate (Single size) : 20mm nominal size M176 Cum 0.57 424.41 241.91
Stone aggregate (Single size) : 10mm nominal size M177 Cum 0.28 297.99 83.44
Carriage of stone aggregate below 40mm nominal size 2202 Cum 0.85 0.00 0.00
Coarse sand (Zone III) M158 Cum 0.43 282.00 119.85
Ordinary/Pozzolona/slag cement M143 tonne 0.57 5,234.00 3,009.55
Carriage of cement 2209 tonne 0.57 0.00 0.00 410 2.05 410 0.41
Plasticizer/super plasticizer (0.50% of cement) 7318 Kg 2.88 30.00 86.25 575 1178.75 575 235.75
Production cost of concrete by batch mix plant/ready mixed plant 0004 Cum 1.00 450.00 450.00 2.875 0.575
Pumping charges of concrete including hire charges of pump, carriage charges for all leads, piping work & accessories etc. 0009 Cum 1.00 250.00 250.00
Total A 4,241.00
Mason 1st class L018 day 0.17 791.00 134.47
Vibrator (Neddle type 40mm) 0012 day 0.07 400.00 28.00
Sundries 9999 LS 13.00 2.27 29.51
Total B 1,313.08
C Add for water charges 5,554.08 1.00% 55.54
D Total A + B + C = D 5,609.62
F Sub Total F D+E 5,609.62
G Add Contractor's OH & Profit @ 15% On F 5,609.62 15.00% 841.44
H Sub Total H E+F 6,451.06
K Total Cost per 1 Sqm H+J 6,515.58
Rate per Sqm 6,520.00
RA-3 #REF! Providing and laying plum concrete course in plain cement concrete M-15 and evenly distributed plums of basalt or trap of size 160 mm and above up to any reasonable size to a maximum limit of 30% by volume of concrete including mechanically vibrating and compacting, centering etc. complete. ( No plums shall be allowed to be projected/protruded with in 150mm from top level of plum concrete). Cost towards formwork shall be included in the quoted rate.
Rate Analysis for 1 Cum 1.00 Cum
AS PER MORKI SR NO.2.5 Cum 1.00 6,500.00 6,500.00
Rate per Cum 6,500.00
RA-4 ROOF SLAB TYPE-1 Providing & fixing of earthquake-resistant Series for Roof Top Covers 150 mm for Expansion Joints having Aluminum Plate at upper predrilled mounting brackets and flexible rubber support. The system should be able to perform as per the Joint size, having desired movement. This Solid all metal roof top cover should be maintenance free, hard wearing and long-lasting model for roof area. This design minimizes noise emission in windy conditions. This model has three-dimensional movement absorption. Also has vertical movement with total 100 percent movement. For Precise Transitions the system should be installed by the way of positive connection between each single length by the way of connecting pins that should ensure a flat level and precise transition.
Rate as per Quotes
Rate as per Migua Rmt 1.00 9,600.00 9,600.00
Average Rate per Rmt 9,600.00
RA-5 ROOF SLAB TYPE-2 Providing & Fixing earthquake-resistant Series Model -RTC Corner Profile for Roof Top Covers for 150MM Expansion Joints, the having Aluminum Plate at upper predrilled mounting brackets and flexible rubber support. The system should be able to perform for 150mm of Joint size, having desired movement This is Solid all metal roof top cover should be maintenance free, hard wearing and long lasting model for roof area. This design minimizes noise emission in windy conditions. This model has three dimensional movement absorption. For Precise Transitions the system should be installed by the way of positive connection between each single length by the way of the connecting pins that should ensure a level and precise transition. Approved Make Expansion Joint.
Rate as per Quotes
Rate as per Migua Rmt 1.00 9,600.00 9,600.00
Average Rate per Rmt 9,600.00
RA-6 ROOF SLAB TYPE-3 Supplying and Installation Flameline Expansion Joint system with FSL-173 Corner Profile, especially design for roof area to accommodate structural movement and ensure complete watertight. Covers for Metal Series, Floor to Corner Model, for 150mm Expansion Joints Aluminum Covers Profiles for Top Finish, having a Hard Wearing, Maintenance Free, long Lasting design having Smooth Surface. The Surface of the Exp. Joint Covers should have Sirated Surface, which should ensure to have a good Skid Resistance so that it avoids any kind of Slippages when used. The design of the Exp. Joint Cover System should be such that it should avoid any accumulation of dirt. The Exp. Joint Cover should have an Articulated Telescope Design so as to accommodate the movements in 3 direction. It should also accommodate a Vertical Movement of 10 mm. The surface of the system should be in the Mill finish. The Total Visible width of the profile should not be 173 mm & the installation Height can be of 35 mm. The system can be used for standard Rolling Loads of 1-2 Cars or Cart Wheel Loads if required. The system should have ASTM1399 E IV certification. Provision of Flameline 100% in the Joint System to have watertight joint is mandatory on the motherslab. The Sealing Strip system is specifically developed compound with ensure to absorb the Three Dimensional movement having a Total Width of 420mm. The material consists of the elastic material Butyl-Elastomer and Very high long-term heat resistance (up to +90° C)/ Very high flexibilty at low temperatures (up to –40° C)/Water pressure up to 0.5 bar/Overall resilience against chemicals:/Very good against alkali, diluted acids and saline solutions/Excellent against vapour/Very good resilience against polar solvents like alcohol/and ketone. The Sealing Strip should have the properties for sealing on the Bitumen sheets, Epoxy/PU Adhesive on Concrete & Metal. The both the side Ends should have the Protruding Fabric which should enable for the Perfect bonding/connecting with Bitumen / Epoxy/PU.Requirement all as per the manufactures design and as approved by the Engineer-in-Charge.
Rate as per Quotes
Rate as per Migua Rmt 1.00 34,500.00 34,500.00
Average Rate per Rmt 34,500.00
RA-7 WALL TYPE-1 (INTERNAL WALL) Supply and installation Symmetric metal wall and ceiling cover is designed for interior and Exterior applications where low-maintenance or tamper resistant applications are desired. The free-floating aluminium centre plate spans the joint and slides between retainer assemblies to allow for required movement. The cover can be anodised or powder coated in any RAL colour. Extrusion shall be of ASTM 6063 T66 standard. Can be used in a variety of wall construction including flush finish in drywall applications also. No exposed fasteners for tamper proof application. For exterior use of water barrier EPDM membrane must be installed below WP profile.
Rate as per Quotes
Rate as per Migua Rmt 1.00 5,000.00 5,000.00
Average Rate per Rmt 5,000.00
RA-8 WALL TYPE-2 (EXTERNAL WALL) Supply and installation Symmetric metal wall and ceiling cover is designed for interior and Exterior applications where low-maintenance or tamper resistant applications are desired. The free-floating aluminium centre plate spans the joint and slides between retainer assemblies to allow for required movement. The cover can be anodised or powder coated in any RAL colour. Extrusion shall be of ASTM 6063 T66 standard. Can be used in a variety of wall construction including flush finish in drywall applications also. No exposed fasteners for tamper proof application. For exterior use of water barrier EPDM membrane must be installed below WP profile.
Rate as per Quotes
Rate as per Migua Rmt 1.00 5,000.00 5,000.00
Average Rate per Rmt 5,000.00
RA-9 FLOOR TYPE-1 Providing & Fixing of the full Metal SEISMIC PAN JOINT (SPJ) System, for Expansion Joints All Aluminium Covers Profiles, having a Hard Wearing, Maintenance Free, long-Lasting design with no Shrink seal and no gasket with straight 90-degree Pan design to take 90 Degree of cut stone. The 90 degrees pan flange and side wall must be single extrusion to maintain smooth and synchronised movement of pan without any hurdle. The profile should be flushed with floor finish once installed. The Exposed Surface of the Exp. Joint Covers should have Micro Serrated Surface, which should ensure to have a good Skid Resistance so that it avoids any kind of Slippages when used. These side flanges should slide smoothly on side frame and must have single piece extrusion with pan side frame to ensure smooth movement. The Exp. Joint Cover should have a Seismic and Articulated Telescope Design so as to accommodate the movements in 3 directions. The turn bar must have 2-part assembly to provide vertical movement. It should also accommodate a Vertical Displacement and Thermal Movement of +/-20mm. The surface of the system should be in Mill finish. The Total Visible width on each Micro Serrated side will be 65mm in the form of flange to accommodate thermal movement & the installation Height will be 60 mm. The mounting brackets will be predrilled. The depth of Pan infill will be 30mm.The system can be used for standard Rolling Loads of 1-2 Cars or Cart Wheel Loads, must be FEM Stress tested by Design load (Cleaning Machine), Wheel load: 2,5 KN – Wheel contact patch: 10x1,0cm, qd=2500 x 1,5/(100x10) = 3,75 MPa. The system must have been tested for movement as per ASTM E 1399-class IV certification. The extrusion should be as ASTM 6063 T66 standards. For Precise Transitions the factory supplied slid-in connection pins should be used during the installation of the cover system. The Exp. Joint Covers/Profile shall be supplied in 3 mt. Cut Length.
Rate as per Quotes
Rate as per Migua Rmt 1.00 26,000.00 26,000.00
Average Rate per Rmt 26,000.00
RA-10 FLOOR TYPE-2 Providing & Fixing Floor to Corner for 150mm mm Expansion Joints, the having Solid All Metal Expansion Joint Cover. Maintenance- Free, Hard wearing and Long-Lasting, Non-Shrink Seal. The cover must be design in such a way that there should be aluminum flange in the sides and no requirement of any gasket or sealant should be there. The profiles are provided with 90° Vertical Side Walls. There Is no diagonal Cuttings of Stoneware necessary. The Exp. Joint System have three-dimensional movement absorption, easy to install with optimized design allows for easy and safe installation of the centering bar. Connection pins to ensure even installation with respect to both, height and width. The system must have tested for movement as per ASTM E 1399/ ASTM 1399 M, class IV certification. The extrusion should be as ASTM 6063 T66 standards. The Exp. Joint Covers/Profile shall be supplied in 3 mt. Cut Length. Provision of Moisture Barrier Membrane in the Joint System to have watertight joint is mandatory requirement all as per the manufactures design and as approved by the Engineer-in-Charge.
Rate as per Quotes
Rate as per Migua Rmt 1.00 26,000.00 26,000.00
Average Rate per Rmt 26,000.00
RA-11 FLOOR TYPE-3 Providing & fixing of the Covers for Interior Metal Series, Floor to Floor Model, for 150 mm Expansion Joints Aluminum Covers Profiles, having a Hard Wearing, Maintenance Free, and long lasting design. The surface of the Exp. Joint Covers should have Serrated Surface for Skid Resistance and should be ADA Compliant. The design of the Exp. Joint Cover System should be such that it should avoid any accumulation of dirt. The Exp. Joint Cover should have an Articulated Telescope Design so as to accommodate the movements in 3 directions both Horizontal & vertical movement. The system should be in 6063 alloy in Mill finish. The system can be used for standard pedestrian load. The side profile should have a MULTI HOLE mounting bracket allowing for secure fixing and Flexible anchoring and excellent bonding with given slab surface/masonry/epoxy bedding. For Precise Transitions the factory supplied slid-in connection pins should be used during the installation of the cover system.
Rate as per Quotes
Rate as per Migua Rmt 1.00 34,500.00 34,500.00
Average Rate per Rmt 34,500.00
RA-12 FLOOR TYPE-4 Providing & Fixing Covers for Interior Metal Series, Model - FSL 113, Floor to Wall Corner Model, for 100 mm Expansion Joints Aluminum Covers Profiles, having a Hard Wearing, Maintenance Free, long Lasting design. The Surface of the Exp. Joint Covers should have Serrated Surface for Skid Resistance and should be ADA Compliant. The design of the Exp. Joint Cover System should be such that it should avoid any accumulation of dirt. The Exp. Joint Cover should have an Articulated Telescope Design so as to accommodate the movements in 3 directions. The total Horizontal Movement should be 45 mm (-/+ 22.5 mm). It should also accommodate a Vertical Movement of 10 mm. The system should be in 6063 alloy in Mill finish and the total exposed surface of the profile should not be more than 113 mm (+/- 5 mm) & the installation Height can be of 20/35/50 mm. The system can be used for standard Rolling loads of private Cars or Cart wheel loads. The side profile should have a MULTI HOLE mounting bracket allowing for secure fixing and Flexible anchoring and excellent bonding with given slab surface/masonry/epoxy bedding. For Precise Transitions the factory supplied slid-in connection pins should be used during the installation of the cover system
Rate as per Quotes
Rate as per Migua Rmt 1.00 34,500.00 34,500.00
Average Rate per Rmt 34,500.00
RA-13 WALL TYPE-3 (INTERNAL) Providing & Fixing Wall and Ceiling Expansion joint Covers, for 30mm to 350 mm Expansion Joints having Flexible High Quality Electromagnetic Inserts to accommodate movements. The Inserts should be Hard Wearing & temperature resistance (- 30 C to + 120 C Degree). Expansion Joint covers/ Profile insert should have a double protection from water due to its double sliding special Foldable Insert that can be installed in continuation length up to 50 RMT. The insert must be wieldable if required to connect two pieces of inserts. The height will be 20mm to accommodate surface material like plaster, gypsum, false ceiling etc. The Side Profile should have a MULTI HOLE mounting bracket allowing for secure fixing and Flexible anchoring and excellent bonding with given slab surface/masonry/epoxy bedding.
Rate as per Quotes
Rate as per Migua Rmt 1.00 6,600.00 6,600.00
Average Rate per Rmt 6,600.00
RA-15 Providing and filling with styrofoam (minimum compressive strength 9.1 T/Sqm and density of 30 Kg/cum) lightweight filling to enable casting of Double slab build-up (refer drawing A14-01, detail-19)
Rate Analysis for 1 Cum 1.00 Cum
Extruded polystyrene rigid insulation board 50 mm thick 8561 Sqm 21.00 517.89 10,875.69
Total A 10,875.69
Total B 3,150.00
C Add for water charges 14,025.69 1.00% 140.26
D Total A + B + C = D 14,165.95
F Sub Total F D+E 14,165.95
G Add Contractor's OH & Profit @ 15% On F 14,165.95 15.00% 2,124.89
H Sub Total H E+F 16,290.84
K Total Cost per 1 Cum H+J 16,453.75
Rate per Cum 16,454.00
RA-16 Toilet Waterproofing
Location : Toilets
Rate as per Quotes
Rate as per Pidilite Sqm 1.00 550.00 550.00
Rate as per Technonicol Sqm 1.00 715.00 715.00
Rate as per MYK Arment Sqm 1.00 655.00 655.00
Min Rate per Sqm + 1.1615 for CPOH 638.83
RA-17 #REF! Providing and filling light weight AAC bats (of size 40-60 mm) with cement mortar mixed in the ratio 1:3:6 (1 cement : 3 coarse sand : 6 block bats) including mixing of approved water proofing compound in recommended proportion. The laid brick bat mix shall be well rammed and compacted as required. Further surfaces shall be screeded with cement concrete mix 1:1.5:3 (1 cement : 1.5 coarse sand : 3 stone grit of size 6 mm and below by volume) admixed with approved integral water proofing compound in recommended proportion, laid to an average thickness of 25mm and finished smooth or ready to receive finish material as specified. Care shall be taken prior to filling all pipes passing through sunk portion such that the pipes are pressure tested by maintaining pressure for 24 hours and junctions of pipes passing through walls, slabs are well grouted and sealed.
Rate Analysis for 1 Cum 1.00 Cum
AAC bats (Considered 70% of AAC Block rate) 8655 Cum 0.85 2,040.50 1,734.43
Coarse Sand 0982 Cum 0.425 1,450.00 616.25
Portland Cement (0.2833 Cum) 0367 tonne 0.40 5,156.00 2,062.40
Waterproofing compound (1 Kg per bag) 1213 Kg 8.00 45.00 360.00
Total A 4,773.08
Mason (brick layer) 1st class 0123 Day 0.06 897.00 53.82
Mason (brick layer) 2nd class 0124 Day 0.06 816.00 48.96
Vibrator (needle type 40mm) 0012 Day 0.07 400.00 28.00
Total B 2,196.06
C Add for water charges On A+B 6,969.14 1.00% 69.69
D Total A + B + C = D D 7,038.83
E Add GST Excluded On D 0.00 0.00
F Sub Total F D+E 7,038.83
G Add Contractor's OH & Profit @ 15% On F 7,038.83 15.00% 1,055.82
H Sub Total H E+F 8,094.65
K Total Cost per 1 Cum H+J 8,175.60
Rate per Cum 8,176.00
RA-18 #REF! #REF!
Rate Analysis for 1 Cum 1.00 Cum
Brick Bats 0362 Cum 0.85 525.00 446.25
Coarse Sand 0982 Cum 0.425 1,450.00 616.25
Portland Cement (0.2833 Cum) 0367 tonne 0.40 5,156.00 2,062.40
Waterproofing compound (1 Kg per bag) 1213 Kg 8.00 45.00 360.00
Total A 3,484.90
Mason (brick layer) 1st class 0123 Day 0.06 897.00 53.82
Mason (brick layer) 2nd class 0124 Day 0.06 816.00 48.96
Vibrator (needle type 40mm) 0012 Day 0.07 400.00 28.00
Total B 2,196.06
C Add for water charges On A+B 5,680.96 1.00% 56.81
D Total A + B + C = D D 5,737.77
E Add GST Excluded On D 0.00 0.00
F Sub Total F D+E 5,737.77
G Add Contractor's OH & Profit @ 15% On F 5,737.77 15.00% 860.67
H Sub Total H E+F 6,598.44
K Total Cost per 1 Cum H+J 6,664.42
Rate per Cum 6,665.00
RA-19 #REF! Water Tank waterproofing
Rate as per Quotes
Rate as per Pidilite Sqm 1.00 1,450.00 1,450.00
Rate as per Technonicol Sqm 1.00 1,150.00 1,150.00
Rate as per MYK Arment Sqm 1.00 2,562.00 2,562.00
Min Rate per Sqm + 1.1615 for CPOH 1,335.73
RA-20 #REF! Internal surface of lift pit
Rate as per Quotes
Rate as per Pidilite Sqm 1.00 420.00 420.00
Rate as per Technonicol Sqm 1.00 480.00 480.00
Rate as per MYK Arment Sqm 1.00 575.00 575.00
Min Rate per Sqm + 1.1615 for CPOH 487.83
RA-21 #REF! Waterproofing on raft slab
Rate as per Quotes
Rate as per Morki item no,4.5 Sqm 1.00 950.00 950.00
Average Rate per Sqm 950.00
RA-22 #REF! Waterproofing outside RCC walls - Vertical
Rate as per Quotes
Rate as per Morki-4.6 Sqm 1.00 2,000.00 2,000.00
Average Rate per Sqm 2,000.00
RA-23 #REF! Terrace Waterproofing with Insulation
Rate as per Quotes
Rate as per Pidilite Sqm 1.00 5,000.00 5,000.00
Rate as per Technonicol Sqm 1.00 3,300.00 3,300.00
Rate as per MYK Arment Sqm 1.00 6,340.00 6,340.00
Average Rate per Sqm + CPOH 3,832.95
RA-23 NDSR Waterproofing with 2K cementitious coating for Waterbodies, consisting of followings:
Rate as per Quotes
Rate as per Pidilite Sqm 1.00 1,615.00 1,615.00
Rate as per Technonicol Sqm 1.00
Rate as per MYK Arment Sqm 1.00 1,565.00
Average Rate per Sqm + CPOH 1,817.75
RA-24 #REF! Providing and fixing 20 mm thick gang saw cut, mirror polished, Premoulded and prepolished, machine cut for kitchen platforms, vanity counters, coping, tread, landscaping, window sills, facias, parapet top and similar locations of required size, approved shade, colour and texture laid over using approved adhesive over cement concrete screed (paid separately), joints grouted with approved matching colour grout epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels, as per sample approved by Engineer in-charge. Necessary MS/ SS frame structure for fixing the stone counter shall be paid in relevant tender item.
8.2.2 Flamed Granite of any colour and shade
11.42 Deduct for not using 20 mm thick cement mortar 1:4 (1 cement : 4 coarse sand) bedding in laying of floor tiles and jointing with grey cement slurry @ 3.3 kg/ sqm. 11.42 Sqm -1.00 850.10 -850.10
11.43 Fixing glazed/ Ceramic/ Vitrified floor tiles with cement based high polymer modified quick- set tile adhesive (Water based) conforming to IS: 15477, in average 3mm thickness. 11.43 Sqm 1.00 753.25 753.25
Additional for 25mm thickness Sqm 1.00 1,000.00 1,000.00
Total including GST 18% 6,039.45
Total excluding GST 5,118.18
RA-25 5.5.1 NDSR 50 mm thick Sand stone of rough finish and colour and shade as per selection, (Basic rate of stone -Rs-400/- per Sqft without GST) Refer A12-08 Det - 1,2,3,4,6
Rate Analysis for 1 Sqm 1.00 Sqm
50mm thick Granite stone (with 25% wastage) Basic Rate Sqm 1.25 4,305.60 5,382.00
Cement based high polymer modified quick- set tile adhesive (Water based) conforming to IS: 15477, in average 3mm thickness. 11.43 Sqm 1.00 638.35 638.35
Total A 6,020.35
Add polish protection etc. Sqm 1.00 538.20 538.20
Total B 2,691.00
C Add for water charges On A+B 8,711.35 1.00% 87.11
D Total A + B + C = D D 8,798.46
E Add GST Excluded On D 0.00 0.00
F Sub Total F D+E 8,798.46
G Add Contractor's OH & Profit @ 15% On F 8,798.46 15.00% 1,319.77
H Sub Total H E+F 10,118.23
K Total Cost per 1 Sqm H+J 10,219.41
Rate per Sqm 10,220.00
RA-26 5.6.1 NDSR Honed finish Steel grey Granite stone slab of 300mm x 300mm (Basic rate of stone -Rs-213/- per Sqft without GST) Refer A12-04 Det -1/A14-01
Rate Analysis for 1 Sqm 1.00 Sqm
25mm thick Honed finished granite stone (with 25% wastage) Basic Rate Sqm 1.25 2,292.73 2,865.92
Cement based high polymer modified quick- set tile adhesive (Water based) conforming to IS: 15477, in average 3mm thickness. 11.43 Sqm 1.00 638.35 638.35
Total A 3,504.26
Add protection. Sqm 1.00 107.64 107.64
Total B 2,260.44
C Add for water charges On A+B 5,764.70 1.00% 57.65
D Total A + B + C = D D 5,822.35
E Add GST Excluded On D 0.00 0.00
F Sub Total F D+E 5,822.35
G Add Contractor's OH & Profit @ 15% On F 5,822.35 15.00% 873.35
H Sub Total H E+F 6,695.70
K Total Cost per 1 Sqm H+J 6,762.66
Rate per Sqm 6,765.00
RA-27 5.6.2 NDSR Polished Grey Granite stone slab of 600mm x 600mm (Basic rate of stone -Rs-232/- per Sqft without GST) Refer A12-04 Det -1/A14-01
Rate Analysis for 1 Sqm 1.00 Sqm
25mm thick Polished finished granite stone (with 25% wastage) Basic Rate Sqm 1.25 2,497.25 3,121.56
Cement based high polymer modified quick- set tile adhesive (Water based) conforming to IS: 15477, in average 3mm thickness. 11.43 Sqm 1.00 638.35 638.35
Total A 3,759.91
Add protection. Sqm 1.00 107.64 107.64
Total B 2,260.44
C Add for water charges On A+B 6,020.35 1.00% 60.20
D Total A + B + C = D D 6,080.55
E Add GST Excluded On D 0.00 0.00
F Sub Total F D+E 6,080.55
G Add Contractor's OH & Profit @ 15% On F 6,080.55 15.00% 912.08
H Sub Total H E+F 6,992.63
K Total Cost per 1 Sqm H+J 7,062.56
Rate per Sqm 7,065.00
RA-28 5.6.3 NDSR Honed finish Mandana-1 stone slab of 900mm x 900mm (Basic rate of stone -Rs-448/- per Sqft without GST) Refer A12-04 Det -1/A14-01
Rate Analysis for 1 Sqm 1.00 Sqm
25mm thick Honed finished granite stone (with 25% wastage) Basic Rate Sqm 1.25 4,822.27 6,027.84
Cement based high polymer modified quick- set tile adhesive (Water based) conforming to IS: 15477, in average 3mm thickness. 11.43 Sqm 1.00 638.35 638.35
Total A 6,666.19
Add protection. Sqm 1.00 107.64 107.64
Total B 2,260.44
C Add for water charges On A+B 8,926.63 1.00% 89.27
D Total A + B + C = D D 9,015.89
E Add GST Excluded On D 0.00 0.00
F Sub Total F D+E 9,015.89
G Add Contractor's OH & Profit @ 15% On F 9,015.89 15.00% 1,352.38
H Sub Total H E+F 10,368.28
K Total Cost per 1 Sqm H+J 10,471.96
Rate per Sqm 10,475.00
RA-29 5.6.4 NDSR Honed finish Sand stone slab of 300mm x 300mm (Basic rate of stone -Rs-377/- per Sqft without GST) Refer A12-04 Det -1/A14-01
Rate Analysis for 1 Sqm 1.00 Sqm
25mm thick Honed finished sand stone (with 25% wastage) Basic Rate Sqm 1.25 4,058.03 5,072.54
Cement based high polymer modified quick- set tile adhesive (Water based) conforming to IS: 15477, in average 3mm thickness. 11.43 Sqm 1.00 638.35 638.35
Total A 5,710.88
Add protection. Sqm 1.00 107.64 107.64
Total B 3,336.84
C Add for water charges On A+B 9,047.72 1.00% 90.48
D Total A + B + C = D D 9,138.20
E Add GST Excluded On D 0.00 0.00
F Sub Total F D+E 9,138.20
G Add Contractor's OH & Profit @ 15% On F 9,138.20 15.00% 1,370.73
H Sub Total H E+F 10,508.93
K Total Cost per 1 Sqm H+J 10,614.02
Rate per Sqm 10,615.00
RA-30 NDSR Providing and fixing 25mm thick approved up to 300mm wide Kota stone treads in 3 peices to full length of step and machine cut, machine polished. Treads to be rounded at front and all exposed edges machine polished. Further treads to have edge polished chamfering with 3 nos. (6mm x 3mm deep) grooves on top at front or as detailed in drawing for antiskid effect as shown in the drawing. Treads fix to be using approved adhesive over cement concrete screed (paid separately), joints grouted with approved matching coulour grout,, curing, cleaning, polishing etc. all complete at all heights and leads to the approval of the Engineer in charge. (Basic rate of stone -Rs-113/- per Sqft) Refer A12-04 Det -4/A14-01
Rate Analysis for 1 Sqm 1.00 Sqm
25mm thick honed finish granite stone (with 25% wastage) Basic Rate Sqm 1.25 1,216.33 1,520.42
Cement based high polymer modified quick- set tile adhesive (Water based) conforming to IS: 15477, in average 3mm thickness. 11.43 Sqm 1.00 638.35 638.35
Total A 2,158.76
B LABOUR for treads Sqm 1.00 3,229.20 3,229.20
Add grooves, protection etc. Sqm 1.00 1,076.40 1,076.40
Total B 4,305.60
C Add for water charges On A+B 6,464.36 1.00% 64.64
D Total A + B + C = D D 6,529.01
E Add GST Excluded On D 0.00 0.00
F Sub Total F D+E 6,529.01
G Add Contractor's OH & Profit @ 15% On F 6,529.01 15.00% 979.35
H Sub Total H E+F 7,508.36
K Total Cost per 1 Sqm H+J 7,583.44
Rate per Sqm 7,585.00
RA-31 0 NDSR Providing and fixing 25mm thick and about 150mm high approved Mandana stone risers, skirting machine cut and machine polished in 3 piece or as directed, to full length of step, stone fixed by approved adhesive on back, to correct line, level and plumb. Joints are well cleaned grouted with matching colour approved readymade grout, curing, polishing, cleaned and where specified or shown in drawing exposed edge of stone rounded / chamfered and polished, skirting to be match with wall cladding/ flooring pattern all complete to the satisfaction of the Engineer in charge. (Basic rate of stone -Rs-448/- per Sqft without GST) Refer A12-04 Det -1/A14-01
Rate Analysis for 1 Sqm 1.00 Sqm
25mm thick honed finish granite stone (with 25% wastage) Basic Rate Sqm 1.25 1,216.33 1,520.42
Cement based high polymer modified quick- set tile adhesive (Water based) conforming to IS: 15477, in average 3mm thickness. 11.43 Sqm 1.00 638.35 638.35
Total A 2,158.76
Add protection etc. Sqm 1.00 161.46 161.46
Total B 2,314.26
C Add for water charges On A+B 4,473.02 1.00% 44.73
D Total A + B + C = D D 4,517.75
E Add GST Excluded On D 0.00 0.00
F Sub Total F D+E 4,517.75
G Add Contractor's OH & Profit @ 15% On F 4,517.75 15.00% 677.66
H Sub Total H E+F 5,195.42
K Total Cost per 1 Sqm H+J 5,247.37
Rate per Sqm 5,250.00
RA-32 5.11 NDSR Providing and fixing 25mm thick approved up to 300mm wide Mandana stone treads in 3 peices to full length of step and machine cut, machine polished. Treads to be rounded at front and all exposed edges machine polished. Further treads to have edge polished chamfering with 3 nos. (6mm x 3mm deep) grooves on top at front or as detailed in drawing for antiskid effect as shown in the drawing. Treads fix to be using approved adhesive over cement concrete screed (paid separately), joints grouted with approved matching coulour grout,, curing, cleaning, polishing etc. all complete at all heights and leads to the approval of the Engineer in charge. (Basic rate of stone -Rs-448/- per Sqft without GST) Refer A12-04 Det -1/A14-01
Rate Analysis for 1 Sqm 1.00 Sqm
25mm thick honed finish granite stone (with 25% wastage) Basic Rate Sqm 1.25 4,822.27 6,027.84
Cement based high polymer modified quick- set tile adhesive (Water based) conforming to IS: 15477, in average 3mm thickness. 11.43 Sqm 1.00 638.35 638.35
Total A 6,666.19
B LABOUR for treads Sqm 1.00 3,229.20 3,229.20
Add grooves, protection etc. Sqm 1.00 1,076.40 1,076.40
Total B 4,305.60
C Add for water charges On A+B 10,971.79 1.00% 109.72
D Total A + B + C = D D 11,081.51
E Add GST Excluded On D 0.00 0.00
F Sub Total F D+E 11,081.51
G Add Contractor's OH & Profit @ 15% On F 11,081.51 15.00% 1,662.23
H Sub Total H E+F 12,743.73
K Total Cost per 1 Sqm H+J 12,871.17
Rate per Sqm 12,875.00
RA-33 5.12 NDSR Providing and fixing 25mm thick and about 150mm high approved Mandana stone risers, skirting machine cut and machine polished in 3 piece or as directed, to full length of step, stone fixed by approved adhesive on back, to correct line, level and plumb. Joints are well cleaned grouted with matching colour approved readymade grout, curing, polishing, cleaned and where specified or shown in drawing exposed edge of stone rounded / chamfered and polished, skirting to be match with wall cladding/ flooring pattern all complete to the satisfaction of the Engineer in charge. (Basic rate of stone -Rs-448/- per Sqft without GST) Refer A12-04 Det -1/A14-01
Rate Analysis for 1 Sqm 1.00 Sqm
25mm thick honed finish granite stone (with 25% wastage) Basic Rate Sqm 1.25 4,822.27 6,027.84
Cement based high polymer modified quick- set tile adhesive (Water based) conforming to IS: 15477, in average 3mm thickness. 11.43 Sqm 1.00 638.35 638.35
Total A 6,666.19
Add protection etc. Sqm 1.00 161.46 161.46
Total B 2,314.26
C Add for water charges On A+B 8,980.45 1.00% 89.80
D Total A + B + C = D D 9,070.25
E Add GST Excluded On D 0.00 0.00
F Sub Total F D+E 9,070.25
G Add Contractor's OH & Profit @ 15% On F 9,070.25 15.00% 1,360.54
H Sub Total H E+F 10,430.79
K Total Cost per 1 Sqm H+J 10,535.10
Rate per Sqm 10,540.00
RA-34 5.14 NDSR Providing, fabricating and laying recessed electro-forged SS304 walk-off grating mat brushed finish made out of stainless steel 304 angle frame and hardware (Balco or equivalent), ADA compliant, slip resistant, custom size as shown in plans fixed on cement concrete bed (concrete bed measured & paid sepretley) with recess to lay mat of overall 100mm thick floor. All the work to be protected till handing over the project & to the approval of EIC. Refer-A12-04 & 8/A14-01
Rate Analysis for 1 Sqm 1.00 Sqm
Recessed SS304 walk-off grating mat brushed finish Basic Rate Sqm 1.00 4,851.00 4,851.00
Misc. LS 500.00
Total A 5,351.00
For protection etc. Sqm 1.00 500.00 500.00
C Add for water charges On A+B 5,851.00 1.00% 58.51
D Total A + B + C = D D 5,909.51
E Add GST Excluded On D 0.00 0.00
F Sub Total F D+E 5,909.51
G Add Contractor's OH & Profit @ 15% On F 5,909.51 15.00% 886.43
H Sub Total H E+F 6,795.94
K Total Cost per 1 Sqm H+J 6,863.90
Rate per Sqm 6,865.00
RA-35 5.14.1 NDSR -Do as above item no-5.14 but for G.I walk off bar grating mat Refer- DET 8A / A14-01, A12-04
Rate Analysis for 1 Sqm 1.00 Sqm
Recessed G.I walk off bar grating mat Basic Rate Sqm 1.00 3,234.00 3,234.00
Misc. LS 500.00
Total A 3,734.00
For protection etc. Sqm 1.00 500.00 500.00
C Add for water charges On A+B 4,234.00 1.00% 42.34
D Total A + B + C = D D 4,276.34
E Add GST Excluded On D 0.00 0.00
F Sub Total F D+E 4,276.34
G Add Contractor's OH & Profit @ 15% On F 4,276.34 15.00% 641.45
H Sub Total H E+F 4,917.79
K Total Cost per 1 Sqm H+J 4,966.97
Rate per Sqm 4,970.00
RA-36 5.19 NDSR Providing and laying 9mm thick approved make tufted multi-level loop pile scroll Carpet tile flooring (500mm x 500mm) as per detailed and instruction of approved manufacturer etc. Carpet flooring shall be fixed over exisiting marble mosaic flooring with as adhesive as recommended by the approved of carpet manufacturer. Required edging angles, junction, entrances etc. shall be fixed and finished with as per recommendation of the carpet manufacturer to approval of the Engineer in charge / Architect. Sub-base floor to be leveled, cleaned all complete at all heights and leads to the entire satisfaction of the Engineer in charge. (Basic rate of tile-Rs-220/- per Sqft without GST) Refer A12-04 & Det -10/A14-01
Rate Analysis for 1 Sqm 1.00 Sqm
9mm thick approved make tufted multi-level loop pile scroll Carpet tile flooring (500mm x 500mm) (with 10% wastage, 10% attic stock) Basic Rate Sqm 1.00 2,983.78 2,983.78
Misc. LS 500.00
Total A 3,483.78
For fixing, protection etc. Sqm 1.00 2,152.80 2,152.80
Total B 2,152.80
C Add for water charges On A+B 5,636.58 1.00% 56.37
D Total A + B + C = D D 5,692.95
E Add GST Excluded On D 0.00 0.00
F Sub Total F D+E 5,692.95
G Add Contractor's OH & Profit @ 15% On F 5,692.95 15.00% 853.94
H Sub Total H E+F 6,546.89
K Total Cost per 1 Sqm H+J 6,612.36
Rate per Sqm 6,615.00
RA-37 5.16 NDSR Providing and laying C.C. pavement of mix M-30 with ready mixed concrete from batching plant. The ready mixed concrete shall be laid and finished with screed board vibrator, vaccum dewatering process and finally finished by floating, brooming with wire brush etc. complete as per specifications and directions of Engineer-in-charge. Refer A12-04 & 2/A14-01
Rate Analysis for 1 Cum 1.00 Cum
A Rate of Item 16.75 for M-25 grade concrete (Excluding GST) 16.75 Sqm 1.00 8,325.25 8,325.25
B Cement consumption for M-25 - 330 kg/cum
Cement consumption for M-30 - 350 kg/cum
Difference = 350-330 = 20 Kg or 0.020 tonne + 3% wastage 0367 tonne 0.021 5,156.00 106.21
Plasticizer / super plasticizer 7318 Kg 0.150 30.00 4.50
C Add for water charges On B 110.71 1.00% 1.11
D Total B + C = D D 111.82
E Add GST Excluded On D 0.00 0.00
F Sub Total F D+E 111.82
G Add Contractor's OH & Profit @ 15% On F 111.82 15.00% 16.77
H Sub Total H E+F 128.59
J Add B & CW Cess @ 1% On H 128.59 1.00% 1.29
K Total Cost per 1 Cum (A+H+J) A+H+J 8,455.13
Rate per Cum 8,456.00
RA-38 5.18 NDSR Providing and fixing of 100mm high 25mm thick 1st quality Teak Wood skirting with SS screws, adhesive etc. all complete Refer -A12-06 & 3/A14-03
Rate Analysis for 10 Sqm 10.00 Sqm
Wood for skirting with 5% wastage Basic Rate Cum 0.0263 247,202.67 6,489.07
Screws, glue etc. for fixing LS 150.00
Total A 6,639.07
For fixing, protection etc. Rmt 10.00 350.00 3,500.00
Total B 3,500.00
C Add for water charges On A+B 10,139.07 1.00% 101.39
D Total A + B + C = D D 10,240.46
E Add GST Excluded On D 0.00 0.00
F Sub Total F D+E 10,240.46
G Add Contractor's OH & Profit @ 15% On F 10,240.46 15.00% 1,536.07
H Sub Total H E+F 11,776.53
K Total Cost per 10 Rmt H+J 11,894.30
Rate per Rmt 1,194.00
RA-39 NDSR Providing and installing 20mm thick approved 1st quality Teak wood plank flooring of approved make with tongue and groove joint system as shown in drawings and instruction of approved manufacturer / PM of approved shade; fixed over 12mm thick approved marine ply surface fixed over existing IPS. Ply shall be chemically treated, seasoned and anti-termite treated including cleaning, treating base concrete screed, treating ply with a thin coat of polyurethane prior to being screwed down to concrete floors prior to fixing and making groove/joint around edges as specified in drawing and by the manufacturer etc. all as detailed in technical specification, drawings and that of approved flooring manufacturer etc. to entire satisfaction of the PM. (Refer drawings No.A12-04 & 05/A14-01)
Rate Analysis for 10 Sqm 1.00 Sqm
Teak wood plank flooring with 10% wastage Basic Rate Cum 0.0028 264,860.00 728.37
Marine grade plywood (12mm BWP grade) Basic Rate Cum 1.1500 1,200.00 1,380.00
PU polish MKT Sqm 1.0000 2,800.00 2,800.00
Anti-termite & chemical tratment LS 150.00
Polyurethane coating (base coat + finish) LS 350.00
Screws, glue etc. for fixing LS 250.00
Total A 5,658.37
For fixing, protection etc. Sqm 1.00 2,263.35 2,263.35
Total B 2,263.35
C Add for water charges On A+B 7,921.71 1.00% 79.22
D Total A + B + C = D D 8,000.93
E Add GST Excluded On D 0.00 0.00
F Sub Total F D+E 8,000.93
G Add Contractor's OH & Profit @ 15% On F 8,000.93 15.00% 1,200.14
H Sub Total H E+F 9,201.07
K Total Cost per 10 Sqm H+J 9,293.08
Rate per Sqm 9,300.00
RA-40 Derived from 13.116 NDSR PU POLISH
Rate Analysis for 10 Sqm 10.00 Sqm
PU polish MKT Lit 1.5600 900.00 1,404.00
PU wood sealer MKT Lit 2.8000 700.00 1,960.00
PU solvent/sealer MKT Lit 2.8500 150.00 427.50
Sanding cloth 150mm wide 5768 Rmt 6.0000 65.00 390.00
Sand paper of assorted gratings 5769 Nos 16.0000 25.00 400.00
PU wood filler putty MKT Kg 1.5000 150.00 225.00
Dhoti (worm out soft cotton cloth) 5771 Nos 2.0000 25.00 50.00
Total A 4,856.50
Polisher 1st class 0167 day 1.66 897.00 1,489.02
Polisher 2nd class 0168 day 3.25 816.00 2,652.00
Beldar/Coolies 0114 day 2.00 736.00 1,472.00
Hire charges of compressor machine spare gun etc, with electric charges 0006 day 1.25 9,750.00 12,187.50
Sundries including scaffolding & T&P etc. 9999 LS 300.00 2.27 681.00
Grinding buffers 5779 day 2.00 255.00 510.00
Total B 18,991.52
C Add for water charges On A+B 23,848.02 1.00% 238.48
D Total A + B + C = D D 24,086.50
E Add GST Excluded On D 0.00 0.00
F Sub Total F D+E 24,086.50
G Add Contractor's OH & Profit @ 15% On F 24,086.50 15.00% 3,612.98
H Sub Total H E+F 27,699.48
K Total Cost per 10 Sqm H+J 27,976.47
Rate per Sqm 2,800.00
RA-41 5.20 NDSR Providing and fixing Wooden deck (25 mm wooden planking, tongued and grooved 2nd quality teak wood planking / flooring including PU polish on GI frame and supports as shown in the drawing. Rate shall include preparing and submitting shop drawings with all fixing details prior to fabrication and execution etc. all complete as shown in the drawing and directed by Engineer in chrage. ('GI frame and support as shown in the drawing to be paid for seperatly) Drg Refer -A12-04 & 12/A14-01
Rate Analysis for 10 Sqm 1.00 Sqm
Wood for flooring with 10% wastage Basic Rate Cum 0.0028 222,482.40 611.83
PU polish MKT Sqm 1.0000 2,800.00 2,800.00
Screws, glue etc. for fixing LS 150.00
Total A 3,561.83
For fixing, protection etc. Rmt 1.00 1,424.73 1,424.73
Total B 1,424.73
C Add for water charges On A+B 4,986.56 1.00% 49.87
D Total A + B + C = D D 5,036.42
E Add GST Excluded On D 0.00 0.00
F Sub Total F D+E 5,036.42
G Add Contractor's OH & Profit @ 15% On F 5,036.42 15.00% 755.46
H Sub Total H E+F 5,791.89
K Total Cost per 1 Sqm H+J 5,849.81
Rate per Sqm 5,850.00
RA-42 DERIVED FROM 11.47 NDSR Providing and laying 10mm thick Vitrified tiles in different sizes (thickness to be specified by the manufacturer), with water absorption less than 0.08% and conforming to IS: 15622, of approved brand & manufacturer, in all colours and shade, in skirting, riser of steps, laid with cement based high polymer modified quick set tile adhesive (water based) conforming to IS: 154 77, including grouting of joints. Drg Refer -Det-07/A14-01
Rate Analysis for 1 Sqm 1.00 Sqm
Vitrified tile Basic Rate Sqm 1.0250 700.00 717.50
carriage of tiles LS 6.24 2.27 150.00
High polymer modified tile adhesive Kg 10.00 10.00 100.00
Mason 1st class day 0.25 897.00 224.25
Coolie day 0.50 736.00 368.00
Sundries including of quick set polymer etc. LS 26.91 2.27 61.09
C Add for water charges On A+B 1,620.84 1.00% 16.21
D Total A + B + C = D D 1,637.04
E Add GST Excluded On D 0.00 0.00
F Sub Total F D+E 1,637.04
G Add Contractor's OH & Profit @ 15% On F 1,637.04 15.00% 245.56
H Sub Total H E+F 1,882.60
K Total Cost per 1 Sqm H+J 1,901.43
Rate per Sqm 1,905.00
RA-43 5.24 NDSR Supply and installation of Rubber Tile Flooring, skirting having thickness of 5mm. This product is installed on floor base with adhesive.
Rubber tile of 5mm is made up of 85% black rubber granules and 15% synthetic EPDM granules. Rich colors, Environmental friendly, non-toxic, Recycled, non-pollution, Moderate and adjusted hardness, Excellent resilience, wear well, soft, anti-slip, anti-fatigue, Density (kg/m3):1000/1200, Hardness (Shore a):68, Stretch (MPA):2.2, Abrasion resistance:0.0075g (ASTM-D4060-01), Rebound resistance:55%, Friction coefficient: trends μs:0.995 trends μk:0.930, Shape deformation:42%, Thickness: 5mm ±0.3mm. etc. all complete as per detail drawing or as per instruction of Engineer in charge. Refer CODE-A12-04 & 3/A14-01
Rate Analysis for 1 Sqm 1.00 Sqm
5mm thick rubber tiles (with 10% wastage & 10% attic stock) Basic Rate Sqm 1.20 2,034.40 2,441.28
Misc. LS 500.00
Total A 2,941.28
Add for protection etc. Sqm 1.00 215.28 215.28
Total B 1,291.68
C Add for water charges On A+B 4,232.96 1.00% 42.33
D Total A + B + C = D D 4,275.28
E Add GST Excluded On D 0.00 0.00
F Sub Total F D+E 4,275.28
G Add Contractor's OH & Profit @ 15% On F 4,275.28 15.00% 641.29
H Sub Total H E+F 4,916.58
K Total Cost per 1 Sqm H+J 4,965.74
Rate per Sqm 4,970.00
RA-44 5.26 NDSR Providing and fixing dry cladding with 35mm thick gang saw cut stone with machine cut edges of uniform colour and size as per drawing, fixed to structural steel frame work and/ or with the help of cramps, pins etc. and sealing the joints with approved weather sealant as per Architectural drawing and direction of Engineer-in-charge. Item to include Providing and fixing adjustable stainless steel (grade 316) cramps of approved quality, required shape and size, adjustable with stainless steel nuts, bolts and washer (total weight not less than 260 gms), for dry stone cladding fixed on frame work at suitable location, including making necessary recesses in stone slab, drilling required holes etc complete as per direction of the Engineer-in-charge.
5.26.1 Sand stone - 35mm thick gang saw cut stone with 5mm wide joint filled approved PU grout (Basic rate of stone -Rs-377/- per Sqft without GST) - 125mm away from the internal wall Refer A12-05 & 6/A14-02
Rate Analysis for 1 Sqm 1.00 Sqm
35mm thick sand stone (with 25% wastage) Basic Rate Sqm 1.25 4,058.03 5,072.54
SS pins, cramps MKT Nos 3.00 1,200.00 3,600.00
Total A 8,672.54
Add protection etc. Sqm 1.00 538.20 538.20
Total B 4,305.60
C Add for water charges On A+B 12,978.14 1.00% 129.78
D Total A + B + C = D D 13,107.92
E Add GST Excluded On D 0.00 0.00
F Sub Total F D+E 13,107.92
G Add Contractor's OH & Profit @ 15% On F 13,107.92 15.00% 1,966.19
H Sub Total H E+F 15,074.10
K Total Cost per 1 Sqm H+J 15,224.84
Rate per Sqm 15,225.00
RA-45 5.30.2 35mm thick satin finish Mandana stone cladding filled approved PU grout (Basic rate of stone -Rs-392/- per Sqft without GST) - 125mm away from the internal wall Refer A12-05 & 6/A14-02
Rate Analysis for 1 Sqm 1.00 Sqm
35mm thick mandhana stone (with 25% wastage) Basic Rate Sqm 1.25 4,219.49 5,274.36
SS pins, cramps MKT Nos 3.00 1,200.00 3,600.00
Total A 8,874.36
Add protection etc. Sqm 1.00 538.20 538.20
Total B 4,305.60
C Add for water charges On A+B 13,179.96 1.00% 131.80
D Total A + B + C = D D 13,311.76
E Add GST Excluded On D 0.00 0.00
F Sub Total F D+E 13,311.76
G Add Contractor's OH & Profit @ 15% On F 13,311.76 15.00% 1,996.76
H Sub Total H E+F 15,308.52
K Total Cost per 1 Sqm H+J 15,461.61
Rate per Sqm 15,465.00
RA-46 5.30.3 35mm thick mirror finish Granite stone cladding filled approved PU grout (Basic rate of stone (Basic rate of stone -Rs-419/- per Sqft without GST) - 125mm away from the internal wall Refer A12-05 & 6/A14-02
Rate Analysis for 1 Sqm 1.00 Sqm
35mm thick granite stone (with 25% wastage) Basic Rate Sqm 1.25 4,510.12 5,637.65
SS pins, cramps MKT Nos 3.00 1,200.00 3,600.00
Total A 9,237.65
Add protection etc. Sqm 1.00 538.20 538.20
Total B 4,305.60
C Add for water charges On A+B 13,543.25 1.00% 135.43
D Total A + B + C = D D 13,678.68
E Add GST Excluded On D 0.00 0.00
F Sub Total F D+E 13,678.68
G Add Contractor's OH & Profit @ 15% On F 13,678.68 15.00% 2,051.80
H Sub Total H E+F 15,730.48
K Total Cost per 1 Sqm H+J 15,887.78
Rate per Sqm 15,888.00
RA-47 NDSR -Do- as above 5.26 but 35mm thick last stone at lintel filled approved PU grout (Basic rate of stone (Location : Interior) (Basic rate of stone -Rs-338/- per Sqft without GST) Drawing no- A11-04- Detail-3 & 4
Rate Analysis for 1 Sqm 1.00 Sqm
50mm thick sand stone Last stone lintle (with 25% wastage) Basic Rate Sqm 1.25 3,638.23 4,547.79
Cement based high polymer modified quick- set tile adhesive (Water based) conforming to IS: 15477, in average 3mm thickness. 11.43 Sqm 1.00 638.35 638.35
Aluminium framing MKT Kg 20.00 550.00 11,000.00
Total A 16,186.14
Add polish protection etc. Sqm 1.00 538.20 538.20
Total B 3,767.40
C Add for water charges On A+B 19,953.54 1.00% 199.54
D Total A + B + C = D D 20,153.07
E Add GST Excluded On D 0.00 0.00
F Sub Total F D+E 20,153.07
G Add Contractor's OH & Profit @ 15% On F 20,153.07 15.00% 3,022.96
H Sub Total H E+F 23,176.03
K Total Cost per 1 Sqm H+J 23,407.79
Rate per Sqm 23,410.00
RA-48 5.30.2 -Do- as above 5.26.1.1 but 250mm away from the external wall Refer A11-01 Det - 02
Rate Analysis for 1 Sqm 1.00 Sqm
35mm thick shot blast finish sand stone (with 25% wastage) Basic Rate Sqm 1.25 3,638.23 4,547.79
Aluminium framing MKT Kg 20.00 550.00 11,000.00
Total A 15,547.79
Add protection etc. Sqm 1.00 538.20 538.20
Total B 6,996.60
C Add for water charges On A+B 22,544.39 1.00% 225.44
D Total A + B + C = D D 22,769.83
E Add GST Excluded On D 0.00 0.00
F Sub Total F D+E 22,769.83
G Add Contractor's OH & Profit @ 15% On F 22,769.83 15.00% 3,415.48
H Sub Total H E+F 26,185.31
K Total Cost per 1 Sqm H+J 26,447.16
Rate per Sqm 26,450.00
RA-49 5.29 NDSR Providing and fixing machine cut, composite patterned wall wet cladding out of 25mm thick flamed finish Granite stone machine cut, machine polished to walls and columns. Stone fixed with required stainless steel pins / dowels / cramps including drilling holes, making notches etc. for securedly fixing with pins / cramps to wall. Stone fixed in position with approved readymix ploymer based adhesive in line and level and in pattern as shown in the drawing. Joints cleaned, grouted with approved ready made ploymer modified PU grout or cured and cleaned, further to include required double legged independent scaffolding etc. complete to the satisfaction of the EIC. (Basic Rate of stone: Rs. 315/- per Sqft without GST) Refer DWG. A14-02 DET 5
Rate Analysis for 1 Sqm 1.00 Sqm
25mm thick polished Granite Stone (with 25% wastage) Basic Rate Sqm 1.25 3,390.66 4,238.33
Cement based high polymer modified quick- set tile adhesive (Water based) conforming to IS: 15477, in average 3mm thickness. 11.43 Sqm 1.00 638.35 638.35
Total A 4,876.67
Add polish protection etc. Sqm 1.00 538.20 538.20
Total B 2,152.80
C Add for water charges On A+B 7,029.47 1.00% 70.29
D Total A + B + C = D D 7,099.77
E Add GST Excluded On D 0.00 0.00
F Sub Total F D+E 7,099.77
G Add Contractor's OH & Profit @ 15% On F 7,099.77 15.00% 1,064.97
H Sub Total H E+F 8,164.73
K Total Cost per 1 Sqm H+J 8,246.38
Rate per Sqm 8,250.00
RA-50 5.31 Providing and laying self leveling mortar using very low emission, polymer modified cementitious floor levelling compound which provides a smooth finish on subfloors before the application of resilient flooring.
Rate Analysis for 10 Sqm 10.00 Sqm
A Material (Quotes received)
Fosroc (Nitoprime 33 + 3mm Cemptop 250 T) Sqm 450.00
Average Rate Kg 450.00
Self Leveling mortar Quote Sqm 11.00 450.00 4,950.00
Total A 4,950.00
Total B 8,073.00
C Add for water charges On A+B 13,023.00 1.00% 130.23
D Total A + B + C = D D 13,153.23
E Add GST Excluded On D 0.00 0.00
F Sub Total F D+E 13,153.23
G Add Contractor's OH & Profit @ 15% On F 13,153.23 15.00% 1,972.98
H Sub Total H E+F 15,126.21
K Total Cost per 1 Sqm H+J 15,277.48
Rate per Sqm 1,528.00
RA-51 Providing and cladding with 1.2 mm thick Grade 304 grade Stainless Steel sheet, scratch resistant, in panel sizes as per approved design, confirming to relevant standards with all mechanical fixtures as per approved drawings and design, moulding of edges, buffing of surface, flushing of joints, silicon sealants, etc. all complete as per direction of Engineer In charge. MS Frame work & ply base shall be paid separately Refer A14-03 /Det-14
Rate Analysis for 1 Sqm 1.00 Sqm
SS Sheet 1.2 mm thick (Grade 304) Kg 9.50 260.00 2,470.00
SS screws, Z-clips, fasteners LS 1.00 250.00 250.00
Silicon sealant Kg 0.10 400.00 40.00
Grinding/buffing consumables LS 1.00 100.00 100.00
Total A 2,860.00
Total B 1,200.00
C Add for water charges On A+B 4,060.00 1.00% 40.60
D Total A + B + C = D D 4,100.60
E Add GST Excluded On D 0.00 0.00
F Sub Total F D+E 4,100.60
G Add Contractor's OH & Profit @ 15% On F 4,100.60 15.00% 615.09
H Sub Total H E+F 4,715.69
K Total Cost per 1 Sqm H+J 4,762.85
Rate per Sqm 4,765.00
RA-52 Providing, fabricating and fixing circular column cladding using 1.2 mm thick Stainless Steel sheet of Grade 304, scratch-resistant finish, formed in curved panels (259mm) to required radius and panel sizes as per approved shop drawings. The work shall include bending, rolling, edge moulding, buffing/polishing to achieve uniform finish, and making flush joints with minimal visible gaps. The cladding shall be fixed over a prepared framework consisting of 50 x 25 mm GI sub-structure anchored to existing MS column (600Ø) using suitable fasteners, along with 6 mm thick flexi-ply (in multiple layers as required) to achieve the desired curvature. Stainless steel sheets shall be fixed using approved Z-clips, mechanical fasteners, and necessary supports ensuring proper alignment, rigidity, and true curvature.The item shall include provision of backing support, fixing accessories, stainless steel screws, spacers, silicon sealant at joints, finishing of edges, necessary cut-outs, and coordination with other services. All work shall be executed as per approved drawings, specifications, and instructions of the Engineer-in-Charge to achieve complete and seamless finish.
Rate Analysis for 1 Sqm 1.00 Sqm
GI RHS steel Kg 9.00 95.00 855.00
Primer + anti-rust coating LS 1.00 80.00 80.00
Fasteners, anchors, cleats, etc. LS 1.00 120.00 120.00
Flexiply 6mm thick (18mm thick-3 layers including waistage) Sqm 3.30 450.00 1,485.00
Adhesive + Screws LS 1.00 180.00 180.00
Z-clips & SS fasteners LS 1.00 250.00 250.00
Total A 5,440.00
Total B 2,000.00
C Add for water charges On A+B 7,440.00 1.00% 74.40
D Total A + B + C = D D 7,514.40
E Add GST Excluded On D 0.00 0.00
F Sub Total F D+E 7,514.40
G Add Contractor's OH & Profit @ 15% On F 7,514.40 15.00% 1,127.16
H Sub Total H E+F 8,641.56
K Total Cost per 1 Sqm H+J 8,727.98
Rate per Sqm 8,730.00
RA-53 Providing and fixing 100 mm high Stainless steel sheet skirting made out of 1.2mm thick Stainless steel sheet SS304 moulded to profile inc sections fixed over 12mm thick marine ply using epoxy adhesives, fixing with screws, teakwood beading etc.),polishing etc , cutting, bending, curing etc all complete. (Drawing no- A12-06 & 4/A14-03
Rate Analysis for 1 Sqm 1.00 Sqm
SS Sheet 1.2 mm thick (Grade 304) Kg 0.95 260.00 247.00
Marine Ply 12 mm Sqm 0.10 1,200.00 120.00
Epoxy adhesive Kg 0.05 400.00 20.00
Screws, fasteners LS 1.00 40.00 40.00
Teakwood beading Rmt 1.00 80.00 80.00
Polishing consumables LS 1.00 30.00 30.00
B LABOUR Sqm 1.00 440.00 440.00
C Add for water charges On A+B 977.00 1.00% 9.77
D Total A + B + C = D D 986.77
E Add GST Excluded On D 0.00 0.00
F Sub Total F D+E 986.77
G Add Contractor's OH & Profit @ 15% On F 986.77 15.00% 148.02
H Sub Total H E+F 1,134.79
K Total Cost per 1 Sqm H+J 1,146.13
Rate per Sqm 1,150.00
RA-54 Providing and laying loose gravel finish over terrace/roof surface, comprising supply of clean, hard, durable, and well-graded natural gravel of approved quality and size (20–40 mm or as specified), free from dust, dirt, and organic impurities.The work shall include thorough preparation of the surface, ensuring that the underlying waterproofing treatment/screed is complete, properly cured, and protected. Gravel shall be spread uniformly over the surface to a required thickness of 40–50 mm (or as directed), carefully leveled and dressed to achieve an even and consistent layer.The gravel layer shall be laid in a manner that ensures proper drainage, avoids displacement, and does not damage the underlying waterproofing system. The item shall include necessary edge retaining arrangements (if required), handling, loading/unloading, transportation, stacking, and all labour, tools, and tackles required for proper execution. All work shall be carried out strictly in accordance with approved drawings, technical specifications, and as directed by the Engineer-in-Charge, ensuring complete coverage and satisfactory performance.
Rate Analysis for 1 Sqm 1.00 Sqm
Gravel (20–40 mm size) consider 50mm with waistage (50%) 7754 Cum 0.08 815.00 61.13
Loading, unloading & stacking LS Cum 0.06 300.00 16.50
B LABOUR Sqm 1.00 135.00 135.00
C Add for water charges On A+B 212.63 1.00% 2.13
D Total A + B + C = D D 214.75
E Add GST Excluded On D 0.00 0.00
F Sub Total F D+E 214.75
G Add Contractor's OH & Profit @ 15% On F 214.75 15.00% 32.21
H Sub Total H E+F 246.96
J Add B & CW Cess @ 1% On H 246.96 1.00% 2.47
K Total Cost per 1 Sqm H+J 249.43
Rate per Sqm 250.00
RA-55 About 100mm overall thickness partition with 12mm thick marine grade Plywood conforming to IS 710 on both sides, further cladded with 12.5mm thick tapered edged plain Gypsum plaster board on both sides side as shown in the drawing. (Refer Drg No. Det-2/A13-08)
CPWD DSR 2023 9.105.2 75mm overall thickness partition with 12.5 mm thick double skin tapered edged plain Gypsum plaster board conforming to IS: 2095: (part I): 2011 (Board with BIS certification marks) 9.105.2 Sqm 1.00 1,543.61 1,543.61
(Rate per Sqm without percentages as per DAR)
Add 1 no. of 12mm thick marine grade ply confirming to IS:710 on both sides (with 10% wastages) 8724 Sqm 2.20 785.00 1,727.00
TOTAL OF MATERIAL A 3,270.61
B LABOUR Sqm 2.00 450.00 900.00
C Add for water charges On A+B 4,170.61 1.00% 41.71
D Total A + B + C = D D 4,212.32
E Add GST Excluded On D 0.00 0.00
F Sub Total F D+E 4,212.32
G Add Contractor's OH & Profit @ 15% On F 4,212.32 15.00% 631.85
H Sub Total H E+F 4,844.16
K Total Cost per 1 Sqm H+J 4,892.60
Rate per Sqm 4,895.00
RA-56 About 100mm overall thickness partition with 12mm thick marine grade Plywood conforming to IS 710 on both sides, further cladded with 12.5mm thick tapered edged plain Gypsum plaster board on both sides side & 50mm insulation as shown in the drawing. (Refer Drg No.A13-08-Detail-3)
CPWD DSR 2023 9.105.2 75mm overall thickness partition with 12.5 mm thick double skin tapered edged plain Gypsum plaster board conforming to IS: 2095: (part I): 2011 (Board with BIS certification marks) 9.105.2 Sqm 1.00 1,543.61 1,543.61
(Rate per Sqm without percentages as per DAR)
Add 1 no. of 12mm thick marine grade ply confirming to IS:710 on both sides (with 10% wastages) 8724 Sqm 2.20 785.00 1,727.00
Thermal Insulation 12.34 Sqm 1.00 596.89 596.89
TOTAL OF MATERIAL A 3,867.50
B LABOUR Sqm 2.00 450.00 900.00
C Add for water charges On A+B 4,767.50 1.00% 47.67
D Total A + B + C = D D 4,815.17
E Add GST Excluded On D 0.00 0.00
F Sub Total F D+E 4,815.17
G Add Contractor's OH & Profit @ 15% On F 4,815.17 15.00% 722.28
H Sub Total H E+F 5,537.45
K Total Cost per 1 Sqm H+J 5,592.82
Rate per Sqm 5,595.00
RA-57 About 400mm overall thickness partition with 19mm thick marine grade Plywood conforming to IS 710 on both sides, (fixed to MS structural column & beamframing-paid separetly) further cladded with 15mm thick oak wooden cladding on planks as approved both side as shown in the drawing. Reuired sub framing to be included in the cost. (Refer Drg No.A13-08-Detail-4)
Base framework Sqm 1.00 2,250.00 2,250.00
19mm thick marine grade plywood conforming to IS:710 on both sides (with 15% wastage) Sqm 2.30 1,450.00 3,335.00
18mm thick wooden cladding / paneling on both sides including polishing / laminate finish complete Sqm 2.30 2,250.00 5,175.00
Necessary hardwood / GI framework, backing supports, screws, adhesive, edge molding, accessories etc. Sqm 1.00 1,150.00 1,150.00
TOTAL OF MATERIAL A 11,910.00
Total B 2,977.50
C Add for water charges On A+B 14,887.50 1.00% 148.88
D Total A + B + C = D D 15,036.38
E Add GST Excluded On D 0.00 0.00
F Sub Total F D+E 15,036.38
G Add Contractor's OH & Profit @ 15% On F 15,036.38 15.00% 2,255.46
H Sub Total H E+F 17,291.83
K Total Cost per 1 Sqm H+J 17,464.75
Rate per Sqm 17,465.00
RA-57 Providing and fixing dry partition for elliptical ramp of about 300 mm overall thickness, consisting of 12 mm thick gypsum board and 18 mm thick marine grade plywood conforming to IS 710 fixed over MS sub-framing attached to structural columns and beams (structural steel work to be paid separately), including providing and fixing all necessary secondary framing members, cleats, screws, fasteners and accessories complete. The partition shall be suitable to receive stone cladding finish as per architectural drawings, including cutting, fitting, making openings, finishing and making good complete, all as per approved drawings, specifications and direction of Engineer-in-Charge. (Refer Drg. No. A13-08-Detail-5).
Base framework Sqm 1.00 2,250.00 2,250.00
19mm thick marine grade plywood conforming to IS:710 on both sides (with 15% wastage) Sqm 2.30 1,450.00 3,335.00
18mm thick wooden cladding / paneling on both sides including polishing / laminate finish complete Sqm 2.30 2,250.00 5,175.00
MS secondary sub-framing members, cleats, brackets, screws, anchors etc. Kg 8.00 110.00 880.00
Necessary hardwood / GI framework, backing supports, screws, adhesive, edge molding, accessories etc. Sqm 1.00 1,150.00 1,150.00
TOTAL OF MATERIAL A 12,790.00
Total B 3,197.50
C Add for water charges On A+B 15,987.50 1.00% 159.88
D Total A + B + C = D D 16,147.38
E Add GST Excluded On D 0.00 0.00
F Sub Total F D+E 16,147.38
G Add Contractor's OH & Profit @ 15% On F 16,147.38 15.00% 2,422.11
H Sub Total H E+F 18,569.48
K Total Cost per 1 Sqm H+J 18,755.18
Rate per Sqm 18,760.00
RA-58 Overall 125mm wide Panelling with 12mm thick marine grade Plywood and 12.5mm thick approved Fire rated Gypsum board as shown in drawings with provision for light fixtures. Refer A12-05 REF : 17/A14-02
75mm overall thickness partition with 12.5mm thick fire rated gypsum board conforming to IS: 2095 including framework complete 9.105.2 Sqm 1.00 2,131.10 2,131.10
Add 12mm thick marine grade plywood conforming to IS:710 (with 15% wastage) 8724 Sqm 1.15 785.00 902.75
Add for provision/cut-outs for light fixtures, backing support, grooves etc. MKT Sqm 2.30 350.00 805.00
Add for additional framework, screws, jointing tape, edge support and accessories MKT Sqm 1.00 275.00 275.00
TOTAL OF MATERIAL A 4,113.85
Total B 1,028.46
C Add for water charges On A+B 5,142.31 1.00% 51.42
D Total A + B + C = D D 5,193.74
E Add GST Excluded On D 0.00 0.00
F Sub Total F D+E 5,193.74
G Add Contractor's OH & Profit @ 15% On F 5,193.74 15.00% 779.06
H Sub Total H E+F 5,972.80
K Total Cost per 1 Sqm H+J 6,032.52
Rate per Sqm 6,035.00
RA-59 Overall 125mm wide Panelling with 12mm thick marine grade Plywood and 15mm thick approved teak wood panel as shown in drawings with provision for light fixtures. Refer A12-05 REF : 7/A14-02
Base framework with backing support and fixing arrangement MKT Sqm 1.00 1,250.00 1,250.00
Add 12mm thick marine grade plywood conforming to IS:710 (with 15% wastage) 8724 Sqm 1.15 785.00 902.75
Add 15mm thick approved teak wood panel including groove formation and fixing (with 15% wastage) MKT Sqm 1.15 3,250.00 3,737.50
Add for provision/cut-outs for light fixtures and necessary supports MKT Sqm 1.00 350.00 350.00
Add for screws, adhesives, edge trims, hardware and accessories MKT Sqm 1.00 275.00 275.00
TOTAL OF MATERIAL A 6,515.25
Total B 1,628.81
C Add for water charges On A+B 8,144.06 1.00% 81.44
D Total A + B + C = D D 8,225.50
E Add GST Excluded On D 0.00 0.00
F Sub Total F D+E 8,225.50
G Add Contractor's OH & Profit @ 15% On F 8,225.50 15.00% 1,233.83
H Sub Total H E+F 9,459.33
K Total Cost per 1 Sqm H+J 9,553.92
Rate per Sqm 9,555.00
RA-60 Providing and fixing panelling with 8mm thick approved flexiply on existing column of 600mm dia. And finish with 6mm thick approved veneer as shown in drawing. REF: 15/A14-03
8mm thick approved flexiply for curved surface fixing (with 15% wastage) MKT Sqm 1.15 1,450.00 1,667.50
6mm thick approved veneer including adhesive and fixing (with 5% wastage) MKT Sqm 1.05 1,850.00 1,942.50
framework, backing support, edge moulding and accessories MKT Sqm 1.00 450.00 450.00
TOTAL OF MATERIAL A 4,060.00
Total B 1,015.00
C Add for water charges On A+B 5,075.00 1.00% 50.75
D Total A + B + C = D D 5,125.75
E Add GST Excluded On D 0.00 0.00
F Sub Total F D+E 5,125.75
G Add Contractor's OH & Profit @ 15% On F 5,125.75 15.00% 768.86
H Sub Total H E+F 5,894.61
K Total Cost per 1 Sqm H+J 5,953.56
Rate per Sqm 5,960.00
RA-61 Providing and fixing Roller blinds (UP-01) (75% black out, made out of 70% PVC, 30% Polyester) of approved make as per the manufacturer's specifications with drive unit, end plug, support brackets, roller tube, bottom rail, ball chains etc. Drive unit to be of moulded plastic with straight rectangular support pin and inserted into the tube end. It shall be driven by a ball chain pulley. End plug shall be moulded to plastic locking pin. The plug shall be inserted into the tube end. Support brackets shall be of zinc plated steel and provided with moulded plastic covers and used in right or left hand positions differentiated by acceptance of the rectangular drive unit support or the round idler plug pin. Roller tube shall be made out of roll formed steel of thick. Suitably protected against corrosion, and keyway integral with the tube to accommodate the spline. Bottom rail shall be a stiffening element inserted into a bottom rod pocket. Tube to be of the material as approved out of timber, PVC, steel or VB bottom rail. Ball chain shall be 2mm diameter cord with acetyl balls moulded co-axially to it on 6mm pitch to form ball chain. Refer A12-14
i) FOH area-99 nos
Details of cost for 5500mm x 2400mm 5500 mm x 2700 mm size
Fabric for blackout curtain MKT Sqm 25.99 650.00 16,891.88
Sheer curtain MKT Sqm 25.99 450.00 11,694.38
SS Rod, brackets MKT Rmt 5.50 350.00 1,925.00
Motor, fitting, fixtures etc. MKT LS 1.00 5,500.00 5,500.00
TOTAL (MATERIAL + LABOUR) 58,286.25
C Add for water charges On A+B 58,286.25 1.00% 582.86
D Total A + B + C = D D 58,869.11
E Add GST Excluded On D 0.00 0.00
F Sub Total F D+E 58,869.11
G Add Contractor's OH & Profit @ 15% On F 58,869.11 15.00% 8,830.37
H Sub Total H E+F 67,699.48
K Total Cost per 4.455 Sqm H+J 68,376.47
Rate per Sqm 4,605.00
RA-62 Providing and fixing thermal insulation with Resin Bonded rock wool conforming to IS: 8183, having density 120 kg/m3,50 mm thick,wrapped in 200 G Virgin Polythene Bags fixed to wall with screw, rawel plug & washers and held and in position by criss cossing GI wire etc. complete as per directions of Engineer in- Charge. (for sound attenuation of mechanical spaces)
i) FOH area-99 nos
Details of cost for 10 Sqm
Area for 10 Sqm (Finished surface)= 10 Sqm + Add 10% for overlappings & wastage= 1 Sqm. Total = 11.00 Sqm
A MATERIAL 120 14040
Resin bonded rockwool 120 kg/m3 Prorata from 7273 Sqm 11.00 295.00 3,245.00 292.5
Sundries including GI wire 20 SWG and virgin polythene bags 200 grams and carriage 9999 L.S 52.00 2.27 118.04
Carpenter 1st class 0111 day 0.50 897.00 448.50
Sundries (Screws & washers) 9999 L.S 20.00 2.27 45.40
TOTAL (MATERIAL + LABOUR) 4,224.94
C Add for water charges On A+B 4,224.94 1.00% 42.25
D Total A + B + C = D D 4,267.19
E Add GST Excluded On D 0.00 0.00
F Sub Total F D+E 4,267.19
G Add Contractor's OH & Profit @ 15% On F 4,267.19 15.00% 640.08
H Sub Total H E+F 4,907.27
K Total Cost per 4.455 Sqm H+J 4,956.34
Rate per Sqm 451.00
RA-63 Providing and fixing partition / panelling upto ceiling height consisting of G.I. framework and approved quality plywood backing with finish paneling, including providing and fixing framework made out of G.I. framing system as required, securely anchored to floor, wall and ceiling with suitable dash fasteners, anchor fasteners, screws and plugs complete. The work shall include providing and fixing 19 mm thick plywood substrate fixed over the G.I. framework with suitable screws, and further providing and fixing 12 mm thick teak wood finished panel with clear polish/ clear finish as approved, fixed over plywood backing with approved adhesive/ screws complete. The item shall include necessary cutting, grooves, edge finishing, making openings for services, providing backing supports, alignment, levelling and all accessories required for complete installation. All joints shall be properly finished flush to surface, including necessary sanding, filling, polishing/ clear coating and finishing as per approved drawings and direction of Engineer-in-Charge, complete in all respects. (Refer-A14-05)
Details of cost for 1 Sqm
G.I. framework MKT Kg 20.00 95.00 1,900.00
19 mm thick plywood backing (with 15 % waistage) MKT Sqm 1.15 1,350.00 1,552.50
12 mm thick teak wood finished panel (with 15 % waistage) MKT Sqm 1.15 3,200.00 3,680.00
6 mm teak veneer reveal strips MKT Rmt 4.00 850.00 3,400.00
Adhesive, screws & fixing accessories MKT LS 1.00 500.00 500.00
Edge finishing, trims & fillers MKT LS 1.00 1,200.00 1,200.00
Sanding, polishing & clear coating MKT LS 1.00 450.00 450.00
B LABOUR 5,073.00
TOTAL (MATERIAL + LABOUR) 17,755.50
C Add for water charges On A+B 30,438.00 1.00% 304.38
D Total A + B + C = D D 18,059.88
E Add GST Excluded On D 0.00 0.00
F Sub Total F D+E 18,059.88
G Add Contractor's OH & Profit @ 15% On F 18,059.88 15.00% 2,708.98
H Sub Total H E+F 20,768.86
K Total Cost per 1 Sqm H+J 20,976.55
Rate per Sqm 20,979.00
RA-64 Providing and fixing wooden louvers approximately 250 mm wide x 60mm thick as per approved drawing and design, comprising 12 mm thick teak finish wooden panels fixed on both sides over stainless steel square tube framework made out of 35 x 35 x 3.2 mm SS sections, complete with internal supports, Further to fix solid teak wood edging with clear polish finish, necessary anchors, fasteners, welding, cutting, grinding, anti-termite treatment and fixing arrangement. The work shall include fabrication of SS framework, provision for alignment, edge finishing, joint treatment, all hardware and accessories, complete in all respects as directed by the Architect/Engineer-in-charge. Measurements shall be taken in running metres of finished surface area. (Refer-A14-05)
Details of cost for 1 louver of size 2400mm x 250mm
SS 304 square tube 35×35×3.2 mm MKT Kg 21.52 550.00 11,837.55
12 mm teak finish wooden panel MKT Cum 0.0109 200,000.00 2,188.80
Solid teak wood edging MKT Cum 0.03 200,000.00 5,088.00
SS anchors, screws & fasteners MKT LS 1.00 750.00 750.00
Adhesive, consumables & accessories MKT LS 1.00 500.00 500.00
Welding, grinding & fabrication consumables MKT LS 1.00 500.00 500.00
Sanding, polishing & clear coating MKT Sqm 1.52 350.00 531.30
B LABOUR 12,837.39
TOTAL (MATERIAL + LABOUR) 34,233.04
C Add for water charges On A+B 55,628.69 1.00% 556.29
D Total A + B + C = D D 56,184.97
E Add GST Excluded On D 0.00 0.00
F Sub Total F D+E 56,184.97
G Add Contractor's OH & Profit @ 15% On F 56,184.97 15.00% 8,427.75
H Sub Total H E+F 64,612.72
K Total Cost per No. of louver of size 2400mm x250mm H+J 65,258.85
Rate per Rmt 27,200.00
RA-65 Providing and fixing of following fully glazed door shutters out of 50mm thick x 100mm wide top, bottom rail and vertical style of 1st quality teakwood, kiln seasoned, antitermite treated, shaped, grooved rebated with required mating styles, joined with tongue and grooved mitered joints arrangement including use of approved water repellent exterior quality adhesive, SS Screws, pins, etc. Also to include two coats of wood primer, two under coats and one finished coat of synthetic enamel paint matt/gloss finish. Also to include 8mm thick toughened glass as detailed, required ironmongery shall be of best quality heavy duty Stainless steel as detailed for each shutters here under.
Door (Type-6) D-B-2F-01, 02, 03, 04, 06, 10, 14, 15, 18, 19, 20, 21, 22, 23, 24 (Location: SNR Admin, Meeting room, Director, Pantry, Documents lounge, File room, Accounts, BLD Management, Curatorial) Single leaf glass doors with overall size of 800mm x 2100mm height, with wooden frame and glass type #5 Insulated (6mm + 12mm + 5mm) 23mm glass with hinges, lever type handles, floor spring and door stopper, eye stop sticker as detailed in drawings.
Details of cost for 1 door of size : 800mm x 2100mm
Wooden rail MKT Cum 0.03 200,000.00 5,800.00
Door frame MKT Cum 0.03 200,000.00 6,500.00
SS Hinges MKT Nos 3.00 264.00 792.00
SS mortise lock MKT Nos 1.00 2,160.00 2,160.00
SS pull/push handles MKT Set 1.00 2,158.00 2,158.00
PU polish MKT Sqm 2.31 2,800.00 6,468.00
SS anchors, screws & fasteners MKT LS 1.00 550.00 550.00 5.3
B LABOUR 8,600.20
TOTAL (MATERIAL + LABOUR) 37,267.51
C Add for water charges On A+B 65,934.83 1.00% 659.35
D Total A + B + C = D D 37,926.86
E Add GST Excluded On D 0.00 0.00
F Sub Total F D+E 37,926.86
G Add Contractor's OH & Profit @ 15% On F 37,926.86 15.00% 5,689.03
H Sub Total H E+F 43,615.89
K Total Cost per No. of Door of size 800mm x2100mm H+J 44,052.05
Rate per Sqm 44,057.00
RA-66 Door (Type-6) D-B-2F-07, D-B-2F-16 (Location : Reception, Conference) Single leaf glass doors with overall size of 1200mm x 2100mm height, with wooden frame and glass type #5 Insulated (6mm + 12mm + 5mm) 23mm with hinges, lever type handles, floor spring and door stopper, eye stop sticker as detailed in drawings.
Details of cost for 1 door of size : 1200mm x 2100mm
Wooden rail MKT Cum 0.03 200,000.00 6,600.00
Door frame MKT Cum 0.04 200,000.00 7,020.00
SS Hinges MKT Nos 3.00 264.00 792.00
SS mortise lock MKT Nos 1.00 2,160.00 2,160.00
SS pull/push handles MKT Set 1.00 2,158.00 2,158.00
PU polish MKT Sqm 2.56 2,800.00 7,173.60
SS anchors, screws & fasteners MKT LS 1.00 550.00 550.00 5.3
B LABOUR 10,055.74
TOTAL (MATERIAL + LABOUR) 43,574.87
C Add for water charges On A+B 77,094.00 1.00% 770.94
D Total A + B + C = D D 44,345.81
E Add GST Excluded On D 0.00 0.00
F Sub Total F D+E 44,345.81
G Add Contractor's OH & Profit @ 15% On F 44,345.81 15.00% 6,651.87
H Sub Total H E+F 50,997.68
K Total Cost per No. of Door of size 1200mm x2100mm H+J 51,507.66
Rate per Sqm 51,512.00
RA-67 Door (Type-6) D-C-G-10 (Location : Restaurant counter) Single leaf glass doors with overall size of 750mm x 2100mm height, with wooden frame and glass type #7 Single pane 8mm thick glass with hinges, lever type handles, floor spring and door stopper as detailed in drawings.
Details of cost for 1 door of size : 1200mm x 2100mm
Wooden rail MKT Cum 0.03 200,000.00 5,700.00
Door frame MKT Cum 0.03 200,000.00 6,435.00
SS Hinges MKT Nos 3.00 264.00 792.00
SS mortise lock MKT Nos 1.00 2,160.00 2,160.00
SS pull/push handles MKT Set 1.00 2,158.00 2,158.00
PU polish MKT Sqm 2.28 2,800.00 6,379.80
8mm thick glass SSR/705 Sqm 1.05 466.10 487.07
SS anchors, screws & fasteners MKT LS 1.00 550.00 550.00 5.3
B LABOUR 7,398.56
TOTAL (MATERIAL + LABOUR) 32,060.44
C Add for water charges On A+B 56,722.31 1.00% 567.22
D Total A + B + C = D D 32,627.66
E Add GST Excluded On D 0.00 0.00
F Sub Total F D+E 32,627.66
G Add Contractor's OH & Profit @ 15% On F 32,627.66 15.00% 4,894.15
H Sub Total H E+F 37,521.81
K Total Cost per No. of Door of size 1200mm x2100mm H+J 37,897.03
Rate per Sqm 37,898.00
Providing and fixing Wooden door with approved 1st quality teak wood door frame of size 45mm x 150mm size, fixed with holdfasts / dash fasteners / SS screws, frame to be finished with PU polish in approved shade to the exposed faces, the frame face in contact with masonry shall be applied with black japan paint. The shutter shall be factory made 45mm thick flush shutter of approved make confirming to IS 2202 (Part - I); Shutter shall be manufactured with exterior quality synthetic adhesive forming marine ply surfaces, internally lipped. Further shutter shall be finished with 4mm thick veneer finish including PU polish on both side of approved make, shade and design, hot pressed at factory, edges of shutter shall be provided with 6mm thick teakwood beadings using exterior quality synthetic adhesive, headless GI nails, screws, beading finished with PU polish, etc. Also including creating pattern / design of paneled shutter as shown in the drawing. Further providing and fixing ironmongeries as per schedule and drawings all complete to entire satisfaction of the PM. (Refer Door Schedule: A13-15,16)
RA-68 Door D-B-G-01 (First Aid) overall size 900mm x 2400mm. with approved 4mm thick veneer finished.
QUOTES RECEIVED
Tufwud No. 1 43,232.00
Navair No. 1 44,001.86
Signum No. 1 45,441.00
Average Rate No. 1 44,224.95
Material inclding fixing No. 1.00 44,224.95 44,224.95
Total A 44,224.95
B LABOUR For Fixing Included above
Protection etc. LS 2,000.00
Total B 2,000.00
C Add for water charges On A+B 46,224.95 1.00% 462.25
D Total A + B + C = D D 46,687.20
E Add GST Excluded On D 0.00 0.00
F Sub Total F D+E 46,687.20
G Add Contractor's OH & Profit @ 15% On F 46,687.20 15.00% 7,003.08
H Sub Total H E+F 53,690.28
K Total Cost per No. H+J 54,227.18
Rate per No. 54,228.00
Providing and fixing Wooden door with approved 1st quality teak wood door frame of size 75mm x 250mm size, fixed with holdfasts / dash fasteners / SS screws, frame to be finished with PU polish in approved shade to the exposed faces, the frame face in contact with masonry shall be applied with black japan paint. The shutter shall be factory made 76mm thick insulated flush shutter of approved make confirming to IS 2202 (Part - I); Shutter shall be manufactured with exterior quality synthetic adhesive forming marine ply surfaces, internally lipped. Further shutter shall be finished with 4mm thick veneer finish including PU polish on both side of approved make, shade and design, hot pressed at factory, edges of shutter shall be provided with 6mm thick teakwood beadings using exterior quality synthetic adhesive, headless GI nails, screws, beading finished with PU polish, etc. Further providing and fixing ironmongeries as per schedule and drawings all complete to entire satisfaction of the PM. (Refer Door Schedule: A13-15,16)
RA-69 Gallery Door (Type-4) D-A-G-03 (Orientation Gallery) & D-A-G-13 (Auditrium Exit), overall size 1800mm x 2400mm
QUOTES RECEIVED
Tufwud No. 1 105,379.00
Navair No. 1 130,163.41
Signum No. 1 84,568.00
Average Rate No. 1 106,703.47
Material inclding fixing No. 1.00 106,703.47 106,703.47
Total A 106,703.47
B LABOUR For Fixing Included above
Protection etc. LS 25,000.00
Total B 25,000.00
C Add for water charges On A+B 131,703.47 1.00% 1317.03
D Total A + B + C = D D 133,020.50
E Add GST Excluded On D 0.00 0.00
F Sub Total F D+E 133,020.50
G Add Contractor's OH & Profit @ 15% On F 133,020.50 15.00% 19,953.08
H Sub Total H E+F 152,973.58
K Total Cost per No. H+J 154,503.32
Rate per No. 154,505.00
RA-70 Gallery Door (Type-3) D-F-G-02 (Temp. Gal), D-G-L-05, D-G-L-06 (Location : Utsah Gal-Entry, Exit) overall size 3000mm x 3600mm, out of which 1800mm wide x 2400mm high openable double leaf door, with approved 4mm thick veneer finished.
QUOTES RECEIVED
Tufwud No. 1 550,397.00
Navair No. 1 130,163.41
Average Rate No. 1 340,280.21
Material inclding fixing No. 1.00 340,280.21 340,280.21
Total A 340,280.21
B LABOUR For Fixing Included above
Protection etc. LS 25,000.00
Total B 25,000.00
C Add for water charges On A+B 365,280.21 1.00% 3652.80
D Total A + B + C = D D 368,933.01
E Add GST Excluded On D 0.00 0.00
F Sub Total F D+E 368,933.01
G Add Contractor's OH & Profit @ 15% On F 368,933.01 15.00% 55,339.95
H Sub Total H E+F 424,272.96
K Total Cost per No. H+J 428,515.69
Rate per No. 428,520.00
Providing and fixing Wooden partly fixed, partly openable, partly galzed door with approved 1st quality teak wood door frame of size 75mm x 250mm size, fixed with holdfasts / dash fasteners / SS screws, frame to be finished with PU polish in approved shade to the exposed faces, the frame face in contact with masonry shall be applied with black japan paint. The shutter along with top fixed portion above shutter shall be factory made 76mm thick insulated flush shutter (with marine grade plywood 19mm thick on both sides and rock wool insulation inside) of approved make; Shutter shall be manufactured with exterior quality synthetic adhesive forming marine ply surfaces, internally lipped. Further shutter shall be finished with 4mm thick veneer finish including PU polish on both side of approved make, shade and design, hot pressed at factory, edges of shutter shall be provided with 6mm thick teakwood beadings using exterior quality synthetic adhesive, headless GI nails, screws, beading finished with PU polish, etc. The side fixed glazed panels shall be as per the drawing. Further providing and fixing ironmongeries as per schedule and drawings all complete to entire satisfaction of the PM. (Refer Door Schedule: A13-15,16)
RA-71 Door (Type-3) D-A-1F-02 (Gaurav Gallery) overall size 3000mm x 3600mm. Double leaf openable wooden shutters of size 1800mm x 2400mm and top fixed portion with approved 4mm thick veneer finished in PU polish, both side portions with fixed glass (#3: Insulated (10mm + 16mm air gap + 8mm) 34mm thick DGU
QUOTES RECEIVED
Tufwud No. 1 576,767.00
Navair No. 1 130,163.41
Average Rate No. 1 353,465.21
Material inclding fixing No. 1.00 353,465.21 353,465.21
Total A 353,465.21
B LABOUR For Fixing Included above
Protection etc. LS 25,000.00
Total B 25,000.00
C Add for water charges On A+B 378,465.21 1.00% 3784.65
D Total A + B + C = D D 382,249.86
E Add GST Excluded On D 0.00 0.00
F Sub Total F D+E 382,249.86
G Add Contractor's OH & Profit @ 15% On F 382,249.86 15.00% 57,337.48
H Sub Total H E+F 439,587.34
K Total Cost per No. H+J 443,983.21
Rate per No. 443,985.00
RA-72 Door (Type-3A) D-B-G-02 (Multipurpose) overall size 2100mm x 2400mm. Double leaf openable shutters of size 1050mm x 2400mm, side portion fixed with glass (#3: Insulated (10mm + 16mm air gap + 8mm) 34mm thick DGU, and top portion fixed 75mm thick with approved 4mm thick veneer finished.
QUOTES RECEIVED
Navair No. 1 130,163.41
Average Rate No. 1 199,660.67
Material inclding fixing No. 1.00 199,660.67 199,660.67
Total A 199,660.67
B LABOUR For Fixing Included above
Protection etc. LS 25,000.00
Total B 25,000.00
C Add for water charges On A+B 224,660.67 1.00% 2246.61
D Total A + B + C = D D 226,907.28
E Add GST Excluded On D 0.00 0.00
F Sub Total F D+E 226,907.28
G Add Contractor's OH & Profit @ 15% On F 226,907.28 15.00% 34,036.09
H Sub Total H E+F 260,943.37
K Total Cost per No. H+J 263,552.80
Rate per No. 263,553.00
RA-73 a) L-Shape Toilet cubicle with standard dimensions of 2000 ± 25mm (Height) x 1000mm (Width) x 1550mm (Depth) consisting of 600 ± 10 mm width of door. The rate includes cost of 12mm Solid compact laminate board along with all necessary fixtures mentioned above.
Detail of 1 No. 1 No.
MATERIAL (Quote Received)
Merino - Titan Box Quote No. 1.00 41,800.00
Average Rate 41,800.00
B LABOUR Included above
C Add for water charges On A+B 41,800.00 1.00% 418.00
D Total A + B + C = D D 42,218.00
E Add GST Excluded On D 0.00 0.00
F Sub Total F D+E 42,218.00
G Add Contractor's OH & Profit @ 15% On F 42,218.00 15.00% 6,332.70
H Sub Total H E+F 48,550.70
K Total Cost per 10 Sqm H+J 49,036.21
Rate per Sqm 49,037.00
RA-74 6.13.2 b) I - shape (front partition) Toilet cubicle with standard dimensions of 2000 ± 25mm (Height) x 1765mm (Width) consisting of 600 ± 10 mm width of door. The rate includes cost of 12mm Solid compact laminate board along with all necessary fixtures mentioned above
Detail of 1 No. 1 No.
MATERIAL (Quote Received)
Merino - Titan Box Quote No. 1.00 38,000.00
Average Rate 38,000.00
B LABOUR Included above
C Add for water charges On A+B 38,000.00 1.00% 380.00
D Total A + B + C = D D 38,380.00
E Add GST Excluded On D 0.00 0.00
F Sub Total F D+E 38,380.00
G Add Contractor's OH & Profit @ 15% On F 38,380.00 15.00% 5,757.00
H Sub Total H E+F 44,137.00
K Total Cost per 10 Sqm H+J 44,578.37
Rate per Sqm 44,579.00
RA-75 Do as above but for steel work in Structural column of covered walkway - specialised CNC fabrication. Refer A16-06
Details of cost for 1 Kg 1 Kg
A Item code 20054, PWD Ahmedabad SOR 2023-24 20054 Kg 1.00 126.68 126.68
Add for CNC cutting & fabrication with high precision MKT Kg 1.00 50.00 50.00
Add transportation loading unloading etc. MKT Kg 1.00 3.00 3.00
Total per Kg 179.68
RA-75a 7.7 Providing, fabricating and fixing G.I. railing system of approved design and profile, comprising vertical posts made of 38 mm dia G.I. pipes (1.2 mm thick), horizontal members of 19 mm dia G.I. pipes, and intermediate supports using G.I. flats (12 x 50 mm) at spacing of 1500 mm c/c, including necessary G.I. pipe plugs (16 mm dia) and all associated components as per approved drawings.
The work shall include cutting, bending, welding, grinding, and finishing of all members to achieve smooth and uniform joints, including factory welding and grinding smooth at connections. The railing shall be fixed to floor/structural base using suitable base plates, anchor fasteners, bolts, and necessary fixtures as approved by the Engineer-in-Charge, ensuring proper alignment, level, and rigidity.
The item shall include providing all materials, labour, tools and tackles, scaffolding, transportation, loading/unloading, and all incidental charges required to complete the work in accordance with approved shop drawings and specifications. The contractor shall prepare and submit detailed shop drawings for approval prior to execution. All complete as per drawings, specifications, and direction of Engineer-in-Charge. Note: For payment, only the weight of G.I. steel members shall be measured; fixing accessories such as nuts, bolts, fasteners, etc., shall not be measured separately. (refer-Detail-7-A12-12 & 07/A7-22)
Detail of 1 Rmt. 1 Rmt
G.I. pipe 38 mm dia 1.2 mm thick 10.26.3 Kg 1.09 203.05 221.02
G.I. flat, 12x50 base plate, pipe plugs and accessories MKT Kg 4.71 150.00 706.50 0.012 0.05
M.S./G.I. work including cutting, welding and erection complete MKT Kg 1.00 250.00 250.00
Primer+enemel paint MKT Kg 1.00 6.50 6.50
Total A 2,017.36
C Add for water charges On A+B 2,420.84 1.00% 24.21
D Total A + B + C = D D 2,445.05
E Add GST Excluded On D 0.00 0.00
F Sub Total F D+E 2,445.05
G Add Contractor's OH & Profit @ 15% On F 2,445.05 15.00% 366.76
H Sub Total H E+F 2,811.80
K Total Cost per 1 Rmt H+J 2,839.92
Rate per Rmt 2,840.00
RA-76 Providing, fabricating and fixing S.S 304 Grade about 300mm high from finished floor level made out of 38mm dia SS pipe as handrail fixed to 10 x 50mm vertical MS flat and SS plate at bottom as shown in the drawing. Rate shall including including fabricating, fixtures, erecting, necessary welding, grinding, finishing, buffing to stainless steel pipe, providing and applying approved compatible primer and enamel paint to MS flat etc. including preparing shop drawings with prior approval of Architect / Engineer in charge etc. (Location : Glazing gaurd Railing) (refer-A12-12 & 03/A7-22)
Detail of 1 Kg. 1 Rmt.
38 mm dia S.S. 304 grade pipe MKT Kg 1.09 203.05 221.02
S.S. plate, fasteners, welding rod and accessories MKT Kg 1.20 150.00 180.00
Primer and enamel paint to M.S. flat MKT L.S 1.00 120.00 120.00
Grinding, buffing and polishing charges MKT L.S 1.00 80.00 80.00
Total A 1,189.77
C Add for water charges On A+B 1,399.77 1.00% 14.00
D Total A + B + C = D D 1,413.77
E Add GST Excluded On D 0.00 0.00
F Sub Total F D+E 1,413.77
G Add Contractor's OH & Profit @ 15% On F 1,413.77 15.00% 212.07
H Sub Total H E+F 1,625.83
K Total Cost per 1 Rmt H+J 1,642.09
Rate per Rmt 1,645.00
RA-77 Providing, fabricating and fixing double handle wooden railing about 800 mm high from finished floor level, comprising 38mm dia. wooden top rail fixed over MS support system as shown in drawing, including 20 × 10 mm MS flat cut to shape (2 Nos), 45 × 10 mm MS flat (2 Nos) for vertical supports, and 25 × 25 × 100 mm MS solid spacers in between at required intervals. The work includes supplying and fixing all components complete with necessary welding, cutting, drilling, grinding and finishing of MS members, providing and applying approved primer and enamel paint to all MS surfaces, and polishing/finishing of wooden railing with approved coating. Item to include all fixtures, fasteners, erection, and preparing shop drawings with prior approval of Architect/Engineer-in-charge, complete as per drawing and site requirements.(refer-A12-12 & 06/A7-22)
Detail of 1 Rmt. 1 Rmt
38 mm dia wooden railing MKT Cum 0.00227 200,000.00 453.42
20×10 mm M.S. flat cut to shape MKT Kg 3.14 150.00 471.00
25×25×100 mm M.S. solid spacers MKT Kg 0.39 250.00 98.13
Welding rods, fasteners & accessories MKT L.S 1.00 350.00 350.00
PU polish MKT Sqm 1.0000 2,800.00 2,800.00
Total A 4,702.42
C Add for water charges On A+B 5,052.42 1.00% 50.52
D Total A + B + C = D D 5,102.94
E Add GST Excluded On D 0.00 0.00
F Sub Total F D+E 5,102.94
G Add Contractor's OH & Profit @ 15% On F 5,102.94 15.00% 765.44
H Sub Total H E+F 5,868.38
K Total Cost per 1 Rmt H+J 5,927.06
Rate per Rmt 5,928.00
RA-78 Providing, fabricating and fixing wall-mounted S.S. 304 grade railing at about 900 mm height from finished floor level, made out of 38 mm dia stainless steel pipe fixed to wall with suitable SS brackets as per drawing. The item shall include all necessary fixtures, anchor fasteners, welding, cutting, grinding, polishing and buffing to achieve stainless steel finish, complete in all respects. Rate shall include preparing shop drawings and obtaining prior approval of Architect /Engineer-in-charge, complete as per drawings and site requirements.(refer-A12-12 & 01/A7-22)
Detail of 1 Rmt. 1 Rmt.
38 mm dia S.S. 304 grade pipe MKT Kg 1.09 203.05 221.02
S.S. wall brackets and base plate MKT Kg 0.90 250.00 225.00
Anchor fasteners, welding rod & accessories MKT LS 1.00 95.00 95.00
Grinding, polishing and buffing charges MKT LS 1.00 110.00 110.00
C Add for water charges On A+B 901.02 1.00% 9.01
D Total A + B + C = D D 910.03
E Add GST Excluded On D 0.00 0.00
F Sub Total F D+E 910.03
G Add Contractor's OH & Profit @ 15% On F 910.03 15.00% 136.50
H Sub Total H E+F 1,046.53
K Total Cost per 1 Rmt H+J 1,057.00
Rate per Rmt 1,060.00
RA-79 Providing, fabricating and fixing wall-mounted wooden railing at about 900 mm height from finished floor level, made out of 38 mm dia wooden member with approved polish finish, fixed to wall using suitable SS brackets as shown in drawing. The work shall include all fixtures, fasteners, necessary cutting, fitting, finishing, polishing, and providing and applying approved primer and enamel paint to MS components. Item includes erection, preparation of shop drawings and approval from Architect/Engineer-in-charge, complete as per drawings and site requirements.(refer-A12-12 & 02/A7-22)
Detail of 1 Rmt. 1 Rmt.
38 mm dia wooden railing MKT Cum 0.00113 200,000.00 226.71
S.S. brackets with base plate MKT Kg 0.90 150.00 135.00
Fasteners, screws and accessories MKT LS 1.00 65.00 65.00
PU polish MKT Sqm 1.0000 2,800.00 2,800.00
Cutting, fitting and polishing charges MKT LS 1.00 60.00 60.00
Total A 3,286.71
C Add for water charges On A+B 3,586.71 1.00% 35.87
D Total A + B + C = D D 3,622.58
E Add GST Excluded On D 0.00 0.00
F Sub Total F D+E 3,622.58
G Add Contractor's OH & Profit @ 15% On F 3,622.58 15.00% 543.39
H Sub Total H E+F 4,165.96
K Total Cost per 1 Rmt H+J 4,207.62
Rate per Rmt 4,212.00
RA-80 Providing, fabricating and fixing wall-mounted wooden handrail system at a height of 1100 mm from finished floor level, comprising 38 mm diameter hardwood railing with approved polish finish, supported on stainless steel brackets anchored to wall, Further 1500mm c/c clamps to fixed glass as per approved drawings. The scope shall include 10 mm thick tempered laminated glass panel fixed in suitable glazing shoe/box with necessary sealant, MS backing plates, trims, and stainless steel fasteners as required. Wooden handrail shall be properly fixed over glass using approved connectors. All MS components shall be treated with approved primer and finished with enamel paint. The work includes all materials, labour, cutting, fitting, edge finishing, polishing, sealant application, hardware, and accessories required for complete installation. Item also includes preparation of shop drawings, obtaining approvals from Architect/Engineer-in-charge, and execution strictly as per drawings, specifications, and site conditions.(refer-A12-12 & 09/A7-22)
Detail of 1 Rmt. 1 Rmt
10 mm thick tempered laminated glass MKT Sqm 1.10 5,500.00 6,050.00
38 mm dia hardwood railing with polish finish MKT Cum 0.00113 200,000.00 226.71
Stainless steel glass clamps MKT Nos 0.67 850.00 569.50
Aluminium/SS glazing shoe with fittings MKT Rmt 1.00 1,250.00 1,250.00
M.S. backing plates, trims and support members MKT Kg 4.50 85.00 382.50
PU polish MKT Sqm 1.0000 2,800.00 2,800.00
Sealant, screws, fasteners & accessories MKT LS 1.00 185.00 185.00
Total A 11,463.71
Total B 1,250.00
C Add for water charges On A+B 12,713.71 1.00% 127.14
D Total A + B + C = D D 12,840.85
E Add GST Excluded On D 0.00 0.00
F Sub Total F D+E 12,840.85
G Add Contractor's OH & Profit @ 15% On F 12,840.85 15.00% 1,926.13
H Sub Total H E+F 14,766.97
K Total Cost per 1 Rmt H+J 14,914.64
Rate per Rmt 14,917.00
RA-81 Providing and fixing wooden grab rail comprising 70 mm dia hardwood member with approved veneer finish, fixed at 900 mm height from finished floor level, supported on MS/GI sub-structure anchored to wall, including 15 mm thick plywood backing with veneer finish, SS/MS brackets, fasteners, and all necessary hardware. The item includes cutting, fitting, finishing, polishing, and application of primer and enamel paint to MS components, complete as per drawings and specifications.(refer-A12-12 & 10/A7-22)
Detail of 1 Rmt. 1 Rmt
70 mm dia hardwood grab rail with veneer/polish finish MKT Cum 0.00385 200,000.00 769.30
15 mm thick plywood MKT Sqm 0.0122 200,000.00 2,430.00 0.81 0.015
M.S./G.I. sub-structure MKT Kg 5.50 150.00 825.00
S.S./M.S. brackets, screws & fasteners MKT LS 1.00 165.00 165.00
PU polish MKT Sqm 1.0000 2,800.00 2,800.00
Adhesive, edge finishing and accessories MKT LS 1.00 110.00 110.00
Total A 7,099.30
Total B 1,250.00
C Add for water charges On A+B 8,349.30 1.00% 83.49
D Total A + B + C = D D 8,432.79
E Add GST Excluded On D 0.00 0.00
F Sub Total F D+E 8,432.79
G Add Contractor's OH & Profit @ 15% On F 8,432.79 15.00% 1,264.92
H Sub Total H E+F 9,697.71
K Total Cost per 1 Rmt H+J 9,794.69
Rate per Rmt 9,797.00
RA-82 Providing, fabricating and fixing fixed glass railing system comprising 10 mm thick tempered laminated safety glass panels, securely fixed in continuous aluminium shoe box with necessary gaskets, sealant, and anchoring arrangement as per approved drawings. The glass panels shall be finished with stainless steel capping at top, properly aligned and fixed. The base shoe shall be supported on MS flat (150 x 9 mm) with approved primer and enamel paint, anchored to RCC base, and integrated with surrounding stone dry cladding as shown.The work shall include all materials, labour, cutting, edge finishing, polishing, drilling, grouting, application of sealant, SS fasteners, and accessories required for complete installation. All exposed metal components shall be finished to approved specifications. The item includes preparation of shop drawings, obtaining approvals from Architect/Engineer-in-charge, and execution strictly as per drawings, specifications, and site conditions, complete in all respects.(refer-A12-12 & 08/A7-22)
Detail of 1 Rmt. 1 Rmt
10 mm thick tempered laminated safety glass MKT Sqm 1.10 5,500.00 6,050.00
Aluminium shoe box/channel with accessories MKT Rmt 1.00 1,350.00 1,350.00
Stainless steel top capping MKT Rmt 1.00 650.00 650.00
M.S. flat 150 × 9 mm with fabrication MKT Kg 10.60 90.00 954.00
Primer and enamel paint to M.S. surface MKT LS 1.00 75.00 75.00
Sealant, gaskets, grouting & S.S. fasteners MKT LS 1.00 325.00 325.00
Edge polishing, drilling & finishing charges MKT LS 1.00 185.00 185.00
Total A 9,589.00
Total B 1,450.00
C Add for water charges On A+B 11,039.00 1.00% 110.39
D Total A + B + C = D D 11,149.39
E Add GST Excluded On D 0.00 0.00
F Sub Total F D+E 11,149.39
G Add Contractor's OH & Profit @ 15% On F 11,149.39 15.00% 1,672.41
H Sub Total H E+F 12,821.80
K Total Cost per 1 Rmt H+J 12,950.02
Rate per Rmt 12,955.00
RA-83 Providing and fixing 2mm thick Aluminium flashing about 100mm wide with necessary accessories as shown in drawing. (Refer-A12-08 & details A11-01 5/6/7/7A
Detail of 1 Rmt. 1 Rmt
2 mm thick aluminium sheet MKT Kg 0.54 450.00 243.00
Aluminium cleats, screws & fasteners MKT LS 1.00 30.00 30.00
Sealant and accessories MKT LS 1.00 20.00 20.00
Cutting and bending charges MKT LS 1.00 35.00 35.00
C Add for water charges On A+B 423.00 1.00% 4.23
D Total A + B + C = D D 427.23
E Add GST Excluded On D 0.00 0.00
F Sub Total F D+E 427.23
G Add Contractor's OH & Profit @ 15% On F 427.23 15.00% 64.08
H Sub Total H E+F 491.31
J Add B & CW Cess @ 1% On H 491.31 1.00% 4.91
K Total Cost per 1 Rmt H+J 496.23
Rate per Rmt 500.00
RA-84 Providing and fixing 2mm thick SS coping about 225mm wide at top of parapet top with necessary accessories as shown in drawing. (Refer-A12-08 & Detail A11-01)
Detail of 1 Rmt. 1 Rmt
2 mm thick S.S. 304 grade sheet MKT Kg 3.53 350.00 1,235.50
S.S. cleats, screws & fasteners MKT LS 1.00 75.00 75.00
Sealant and accessories MKT LS 1.00 45.00 45.00
Cutting, bending and folding charges MKT LS 1.00 95.00 95.00
Grinding and polishing charges MKT LS 1.00 65.00 65.00
Total A 1,515.50
C Add for water charges On A+B 1,715.50 1.00% 17.16
D Total A + B + C = D D 1,732.66
E Add GST Excluded On D 0.00 0.00
F Sub Total F D+E 1,732.66
G Add Contractor's OH & Profit @ 15% On F 1,732.66 15.00% 259.90
H Sub Total H E+F 1,992.55
K Total Cost per 1 Rmt H+J 2,012.48
Rate per Rmt 2,015.00
RA-85 7.12.1 Door DS-A-L-01, DS-B-1F-05, DS-F-G-04, DS-G-G-03, DS-J-L-09, DS-J-G-05, DS-J-1F-05, DS-J-1F-07, D-M-G-01, D-M-G-02 (Location PHE Shaft, Toilet-Male & Female), sigle leaf, size 600mm x 1500mm, with SS hardware of approved make
Rate as per Quotes
Rate as per Shakti-Horman Nos 1.00
Rate as per JC fire door Nos 1.00 8,730.00 8,730.00
Rate as per Navair Nos 1.00 11,857.60 11,857.60
Min +CPOH 10,139.90
RA-86 3.2 Door (Type-8) D-A-G-06, D-A-G-07 (Location Audi Green Room Toilets), D-J-L-20, D-J-L-21 (Location : Staff Toilet-M & F), sigle leaf, size 750mm x 2100mm, with SS hardware of approved make
Rate as per Quotes
Rate as per Shakti-Horman Nos 1.00
Rate as per JC fire door Nos 1.00 23,333.00 23,333.00
Rate as per Navair Nos 1.00 15,965.80 15,965.80
Min +CPOH 18,544.28
RA-87 3.3 Door (Type-7A) D-B-L-01 (Location : Security Monitor), size 1200mm x 2100mm, with double unequal leaves door shutters (900mm + 300mm) with SS hardware of approved make
Rate as per Quotes
Rate as per Shakti-Horman Nos 1.00
Rate as per JC fire door Nos 1.00 23,856.00 23,856.00
Rate as per Navair Nos 1.00 23,572.00 23,572.00
Min +CPOH 27,378.88
RA-88 3.4 Door (Type-7B)D-A-G-12, (Location Service Passage), size 1500mm x 2100mm, with double leaf door shutters with SS hardware of approved make
Rate as per Quotes
Rate as per Shakti-Horman Nos 1.00
Rate as per JC fire door Nos 1.00 30,756.00 30,756.00
Rate as per Navair Nos 1.00 27,677.20 27,677.20
Min +CPOH 32,147.07
RA-89 3.5 Door (Type-DS1) DS-A-G-02 (Location PHE Shaft), sigle leaf, size 600mm x 1800mm, with 35mm thick sand stone cladding on outer face, SS hardware of approved make
Rate as per Quotes
Rate as per Shakti-Horman Nos 1.00
Rate as per JC fire door Nos 1.00 9,504.00 9,504.00
Rate as per Navair Nos 1.00 12,362.80 12,362.80
Average Rate per Nos 10,935.00
35mm thick Honed finished sand stone (with 25% wastage) Basic Rate Sqm 1.08 4,058.03 4,382.67
12 mm thick marine plywood conforming to IS: 710 8724 Sqm 1.08 785.00 847.80
M.S. frame and shutter structure fabrication MKT Kg 32.00 85.00 2,720.00
Adhesive, screws, fasteners & accessories MKT LS 1.00 425.00 425.00
Total-A 19,310.47
LABOUR (For Fixing Stone) MKT Sqm 1.00 2,500.00 2,500.00
Total 21,815.00
RA-90 3.6 Door (Type-DS1) DS-A-G-03, DS-J-L-03, DS-J-L-04,DS-A-1F-03, DS-J-2F-03, DS-J-4F-03, D-B-1F-02 (Location PHE Shaft), sigle leaf, size 600mm x 1800mm, with SS hardware of approved make
Rate as per Quotes
Rate as per Shakti-Horman Nos 1.00
Rate as per JC fire door Nos 1.00 9,504.00 9,504.00
Rate as per Navair Nos 1.00 12,362.80 12,362.80
Min +CPOH 11,038.90
RA-91 3.7 Door D-A-1F-04, D-C-1F-01, D-F-G-03, D-G-L-01, D-G-G-02, D-G-1F-01, D-J-L-14, D-J-G-04, D-J-1F-07, D-J-2F-03 (Location: Service Passage, Bontiful Gallery-BOH, Temp Gal-Serv, Utsah Gal-BOH, Siddhi Gal-BOH), size 2700mm x 3000mm, with double unequal leaves door shutters (1200mm + 1500mm) with pait finished 12mm thick gypsum board + 12mm thick Plywood backing on one side of the door, including SS hardware of approved make
Rate as per Quotes
Rate as per Shakti-Horman Nos 1.00
Rate as per JC fire door Nos 1.00 66,250.00 66,250.00
Rate as per Navair Nos 1.00 53,797.60 53,797.60
Min +CPOH 62,485.91
12 mm thick marine plywood conforming to IS: 710 8724 Sqm 8.10 785.00 6,358.50
12.5 mm thick gypsum board with jointing & finishing MKT Sqm 8.10 850.00 6,885.00
Screws, fasteners, adhesive & accessories MKT LS 1.00 1,250.00 1,250.00
Total-A 76,979.41
LABOUR MKT Sqm 1.00 1,500.00 1,500.00
Total 78,480.00
RA-92 3.8 Door DS-A-2F-02 (Location PHE Shaft), sigle leaf, size 600mm x 2100mm, with 35mm thick stone cladding on outer face, SS hardware of approved make
Rate as per Quotes
Rate as per Shakti-Horman Nos 1.00
Rate as per JC fire door Nos 1.00 10,278.00 10,278.00
Rate as per Navair Nos 1.00 13,736.80 13,736.80
Min + CPOH 11,937.90
RA-93 3.9 Door (Type-7) D-B-L-04 (Location : Staff Break room), & D-B-L-07 (Location : Industrial First Aid) & D-B-M-02 (Location : Security), D-C-G-01 (Location : baby care), D-F-1F-07 (Location : Janitor room), D-J-L-17, D-J-G-08 (Location : Baby care), D-J-3F-02 (Location : Service passage), D-J-4F-13 (Location : Kitchen terrace), D-J-4F-14 (Location : Bakery+storage), D-K-G-02 (Location : Store), D-K-G-05 (Location : Service door), D-V-G-01 (Location : Security cabin) size 900mm x 2100mm, with signle leaf door shutters with SS hardware of approved make
Rate as per Quotes
Rate as per Shakti-Horman Nos 1.00
Rate as per JC fire door Nos 1.00 19,187.00 19,187.00
Rate as per Navair Nos 1.00 18,451.60 18,451.60
Min + CPOH 21,431.53
RA-94 3.10 Door (Type-7) D-B-L-06 (Location: Security locker, access door), size 900mm x 2100mm, with single leaf door shutters with SS hardware of approved make
Rate as per Quotes
Rate as per Shakti-Horman Nos 1.00
Rate as per JC fire door Nos 1.00 26,287.00 26,287.00
Rate as per Navair Nos 1.00 18,451.60 18,451.60
Min + CPOH 21,431.53
RA-95 3.11 Door (Type-8) D-B-L-08, D-B-L-09, D-B-M-08, D-B-M-09, D-B-2F-12, D-B-2F-13, (Location: Staff Toilet M & F, Staff Lokcer room, Toilet male & Female, Kitchen admin), size 900mm x 2100mm, with single leaf door shutters with SS hardware of approved make
Rate as per Quotes
Rate as per Shakti-Horman Nos 1.00
Rate as per JC fire door Nos 1.00 18,587.00 18,587.00
Rate as per Navair Nos 1.00 18,451.60 18,451.60
Min + CPOH 21,431.53
RA-96 3.12 Door (Type-7A) D-B-L-10 (Location : Storage, AV Store), size 1200mm x 2100mm, with double unequal leaves door shutters (900mm + 300mm) with fire rated SS hardware of approved make
Rate as per Quotes
Rate as per Shakti-Horman Nos 1.00
Rate as per JC fire door Nos 1.00 31,156.00 31,156.00
Rate as per Navair Nos 1.00 23,634.40 23,634.40
Min + CPOH 27,451.36
RA-97 3.13 Door (Type-7) D-B-L-11 (Location : Janitor room), size 750mm x 2100mm,with single leaf door shutters with SS hardware of approved make
Rate as per Quotes
Rate as per Shakti-Horman Nos 1.00
Rate as per JC fire door Nos 1.00 28,396.00 28,396.00
Rate as per Navair Nos 1.00 21,776.80 21,776.80
Min + CPOH 25,293.75
RA-98 3.14 Door (Type-7B) D-B-L-13 (Location : Waste Management), size 1500mm x 2100mm, with double equal leaves door shutters (750mm + 750mm) with fire rated SS hardware of approved make
Rate as per Quotes
Rate as per Shakti-Horman Nos 1.00
Rate as per JC fire door Nos 1.00 97,960.00 97,960.00
Rate as per Navair Nos 1.00 21,776.80 21,776.80
Min + CPOH 25,293.75
RA-99 3.15 Door (Type-DS1) DS-B-1F-01, DS-B-1F-03, DS-F-1D-04 (Location PHE Shaft), sigle leaf, size 900mm x 1500mm, with SS hardware of approved make
Rate as per Quotes
Rate as per Shakti-Horman Nos 1.00
Rate as per JC fire door Nos 1.00 10,665.00 10,665.00
Rate as per Navair Nos 1.00 13,723.60 13,723.60
Min + CPOH 12,387.40
RA-100 3.16 Door DS-B-L-01 (Location : PHE Shaft), sigle leaf, size 600mm x 1500mm, with SS hardware of approved make
Rate as per Quotes
Rate as per Shakti-Horman Nos 1.00
Rate as per JC fire door Nos 1.00 8,730.00 8,730.00
Rate as per Navair Nos 1.00 11,305.60 11,305.60
Min + CPOH 10,139.90
RA-101 3.17 Door (Type-7A) D-B-M-01 (Location: Housekeeping), size 1200mm x 2100mm, with double unequal leaves door shutters (900mm + 300mm) with including SS hardware of approved make
Rate as per Quotes
Rate as per Shakti-Horman Nos 1.00
Rate as per JC fire door Nos 1.00 31,156.00 31,156.00
Rate as per Navair Nos 1.00 23,634.40 23,634.40
Min + CPOH 27,451.36
RA-102 3.18 Door (Type-7B) D-B-M-05 (Location: Staff Ent/Fire Exit, access door), size 1800mm x 2100mm, with double equal leaf door shutters (900mm + 900mm) with SS hardware of approved make
Rate as per Quotes
Rate as per Shakti-Horman Nos 1.00
Rate as per JC fire door Nos 1.00 47,674.00 47,674.00
Rate as per Navair Nos 1.00 30,284.80 30,284.80
Min + CPOH 35,175.80
RA-103 3.19 Door (Type-7) D-B-M-06, D-C-G-04 (Location: Janitor room, Kitchen changing room), sigle leaf, size 750mm x 2100mm, with SS hardware of approved make
Rate as per Quotes
Rate as per Shakti-Horman Nos 1.00
Rate as per JC fire door Nos 1.00 24,933.00 24,933.00
Rate as per Navair Nos 1.00 17,007.40 17,007.40
Min + CPOH 19,754.10
RA-104 3.20 Door (Type-DS1) DS-B-L-02, DS-B-M-02, DS-B-G-02 (Location : FF shaft, Plumbing Shaft), sigle leaf, size 900mm x 1500mm, with SS hardware of approved make
Rate as per Quotes
Rate as per Shakti-Horman Nos 1.00
Rate as per JC fire door Nos 1.00 10,665.00 10,665.00
Rate as per Navair Nos 1.00 13,723.60 13,723.60
Min + CPOH 12,387.40
RA-105 3.21 Door (Type-DS1) DS-B-M-03, DS-B-G-05 (Location :Plumbing Shaft), sigle leaf, size 600mm x 1500mm, with SS hardware of approved make
Rate as per Quotes
Rate as per Shakti-Horman Nos 1.00
Rate as per JC fire door Nos 1.00 8,730.00 8,730.00
Rate as per Navair Nos 1.00 11,305.60 11,305.60
Min + CPOH 10,139.90
RA-106 3.22 Door (Type-7) D-B-G-03, D-B-G-04, D-B-G-11, D-B-G-12, D-B-1F-05, D-B-1F- 06, D-F-G-05, D-F-G-06, D-F-1F-08, D-F-1F-09, D-G-L-07, D-G-L-09, D-G-G-08, D-G-G-09, D-J-L-15, D-J-L-16, D-J-G-07, D-J-G-10, D-J-1F-03, D-J-1F-05, D-J-1F-09, D-J-1F-11, D-J-2F-04, D-J-2F-05, D-J-4F-02, D-J-4F-05, D-M-G-01, D-M-G-03 (Location Toilet Female & Male), sigle leaf, size 900mm x 2400mm, with SS hardware of approved make
Rate as per Quotes
Rate as per Shakti-Horman Nos 1.00
Rate as per JC fire door Nos 1.00 32,980.00 32,980.00
Rate as per Navair Nos 1.00 19,196.80 19,196.80
Min + CPOH 22,297.08
RA-107 3.23 Door (Type-7B) D-B-G-06 (Location: Furniture store), size 1500mm x 2400mm, with double equal leaves door shutters (750mm + 750mm) with pait finished 12mm thick gypsum board + 12mm thick Plywood backing on one side of the door, including SS hardware of approved make
Rate as per Quotes
Rate as per Shakti-Horman Nos 1.00
Rate as per JC fire door Nos 1.00 55,560.00 55,560.00
Rate as per Navair Nos 1.00 30,664.00 30,664.00
12 mm thick marine plywood conforming to IS: 710 8724 Sqm 3.60 785.00 2,826.00
12.5 mm thick gypsum board with jointing & finishing MKT Sqm 3.60 850.00 3,060.00
Screws, fasteners, adhesive & accessories MKT LS 1.00 1,250.00 1,250.00
Total-A 37,800.00
LABOUR MKT Sqm 1.00 1,500.00 1,500.00
Total 39,304.00
RA-108 3.24 Door (Type-7A) D-B-G-07 (Location: Service passage), size 2700mm x 3000mm, with double unequal leaves door shutters (1200mm + 1500mm) with pait finished 12mm thick gypsum board + 12mm thick Plywood backing on one side of the door, including SS hardware of approved make
Rate as per Quotes
Rate as per Shakti-Horman Nos 1.00
Rate as per JC fire door Nos 1.00 80,310.00 80,310.00
Rate as per Navair Nos 1.00 53,243.20 53,243.20
min rate 53,243.20
12 mm thick marine plywood conforming to IS: 710 8724 Sqm 8.10 785.00 6,358.50
12.5 mm thick gypsum board with jointing & finishing MKT Sqm 8.10 850.00 6,885.00
Screws, fasteners, adhesive & accessories MKT LS 1.00 1,250.00 1,250.00
Total-A 67,736.70
LABOUR MKT Sqm 1.00 1,500.00 1,500.00
Total 69,238.00
RA-109 3.25 Door (Type-7A) D-J-L-02 (Location: Service passage), size 2700mm x 3000mm, with double unequal leaves door shutters (1200mm + 1500mm) with SS hardware of approved make
Rate as per Quotes
Rate as per Shakti-Horman Nos 1.00
Rate as per JC fire door Nos 1.00 66,250.00 66,250.00
Rate as per Navair Nos 1.00 53,243.20 53,243.20
Min + CPOH 61,841.98
RA-110 3.26 Door (Type-7) D-B-G-10 Location : Janitor room), sigle leaf, size 750mm x 2100mm, with SS hardware of approved make
Rate as per Quotes
Rate as per Shakti-Horman Nos 1.00
Rate as per JC fire door Nos 1.00 23,333.00 23,333.00
Rate as per Navair Nos 1.00 17,065.00 17,065.00
Min + CPOH 19,821.00
RA-111 3.27 Door DS-B-G-01 (Location PHE Shaft), sigle leaf, size 600mm x 1800mm, with SS hardware of approved make
Rate as per Quotes
Rate as per Shakti-Horman Nos 1.00
Rate as per JC fire door Nos 1.00 10,390.00 10,390.00
Rate as per Navair Nos 1.00 12,362.80 12,362.80
Min + CPOH 12,067.99
RA-112 3.28 Door (Type-7A) D-B-G-07 (Location: Service passage), size 2700mm x 3000mm, with double unequal leaves door shutters (1200mm + 1500mm) with pait finished 12mm thick gypsum board + 12mm thick Plywood backing on one side of the door, including SS hardware of approved make
Rate as per Quotes
Rate as per Shakti-Horman Nos 1.00
Rate as per JC fire door Nos 1.00 80,310.00 80,310.00
Rate as per Navair Nos 1.00 53,243.20 53,243.20
min rate 53,243.20
12 mm thick marine plywood conforming to IS: 710 8724 Sqm 8.10 785.00 6,358.50
12.5 mm thick gypsum board with jointing & finishing MKT Sqm 8.10 850.00 6,885.00
Screws, fasteners, adhesive & accessories MKT LS 1.00 1,250.00 1,250.00
Total-A 67,736.70
LABOUR MKT Sqm 1.00 1,500.00 1,500.00
Total 69,240.00
RA-113 3.28 Door (Type-DS2) DS-B-2F-02 (Location PHE Shaft), sigle leaf, size 1200mm x 1800mm, with double equal leaves door shutter (600mm x 600mm), with SS hardware of approved make
Rate as per Quotes
Rate as per Shakti-Horman Nos 1.00
Rate as per JC fire door Nos 1.00 16,330.00 16,330.00
Rate as per Navair Nos 1.00 19,030.00 19,030.00
Min + CPOH 18,967.29
RA-114 3.28 Door (Type-7A) D-C-L-01 (Location : Wet waste), sigle leaf, size 1500mm x 2100mm, with double unequal leaves door shutter (900mm + 600mm) with SS hardware of approved make
Rate as per Quotes
Rate as per Shakti-Horman Nos 1.00
Rate as per JC fire door Nos 1.00 66,985.00 66,985.00
Rate as per Navair Nos 1.00 27,917.20 27,917.20
Min + CPOH 32,425.83
RA-115 3.28 Door (Type-7B) D-C-G-02, D-E-1F-02, D-F-1F-04 (Location : Kitchen-BOH, AHU Entry, Pantry-BOH), size 1500mm x 2100mm, with double equal leaves door shutters (750mm + 750mm) with fire rated SS hardware of approved make
Rate as per Quotes
Rate as per Shakti-Horman Nos 1.00
Rate as per JC fire door Nos 1.00 66,985.00 66,985.00
Rate as per Navair Nos 1.00 26,402.80 26,402.80
Min + CPOH 30,666.85
RA-116 3.28 Door (Type-12) D-C-G-07, D-C-G-08 (Location : Kitchen), size 1500mm x 2100mm, with double equal leaves door shutters (750mm + 750mm) with fire rated SS hardware of approved make
Rate as per Quotes
Rate as per Shakti-Horman Nos 1.00
Rate as per JC fire door Nos 1.00 50,240.00 50,240.00
Rate as per Navair Nos 1.00 37,102.00 37,102.00
Min + CPOH 43,093.97
RA-117 3.28 Door (Type-12) D-C-G-09 (Location : Kitchen-FOH), size 1800mm x 2100mm, with double equal leaves door shutters (900mm + 900mm) with fire rated SS hardware of approved make
Rate as per Quotes
Rate as per Shakti-Horman Nos 1.00
Rate as per JC fire door Nos 1.00 53,768.00 53,768.00
Rate as per Navair Nos 1.00 40,427.20 40,427.20
Min + CPOH 46,956.19
RA-118 3.28 Door (DS-3)DS-C-G-02, DS-G-L-02 (Location : PHE Shaft), sigle leaf, size 900mm x 1500mm, with double unequal leaves shutter (600mm + 300mm) with SS hardware of approved make
Rate as per Quotes
Rate as per Shakti-Horman Nos 1.00
Rate as per JC fire door Nos 1.00 14,725.00 14,725.00
Rate as per Navair Nos 1.00 15,144.40 15,144.40
Min + CPOH 17,103.09
RA-119 3.28 Door (Type-7B) D-B-G-06 (Location: Furniture store), size 1500mm x 2400mm, with double equal leaves door shutters (750mm + 750mm) with SS hardware of approved make
Rate as per Quotes
Rate as per Shakti-Horman Nos 1.00
Rate as per JC fire door Nos 1.00 55,560.00 55,560.00
Rate as per Navair Nos 1.00 30,664.00 30,664.00
Min + CPOH 35,616.24
RA-120 3.28 Door (Type-7A) D-F-G-04 (Location: Temp Gal-Serv), size 2700mm x 3000mm, with double unequal leaves door shutters (1200mm + 1500mm) with 35mm thick sand stone fire rated SS hardware of approved make
Rate as per Quotes
Rate as per Shakti-Horman Nos 1.00
Rate as per JC fire door Nos 1.00 80,010.00 80,010.00
Rate as per Navair Nos 1.00 53,243.20 53,243.20
Min + CPOH 61,841.98
RA-121 3.28 Door (Type-7B) D-F-G-10 (Location : Service passage), size 3000mm x 3000mm, with Double leaf equal door shutters (1500mm + 1500mm) with fire rated SS hardware of approved make
Rate as per Quotes
Rate as per Shakti-Horman Nos 1.00
Rate as per JC fire door Nos 1.00 68,760.00 68,760.00
Rate as per Navair Nos 1.00 53,243.20 53,243.20
Min + CPOH 61,841.98
RA-122 3.28 Door (Type-7B) D-F-1F-02, D-F-1F-03 (Location : Storage, VIP lounge-Pantry), size 1500mm x 2400mm, with double equal leaf door shutter (750mm + 750mm) with 12mm thick Plywood backing on one side of the door finish with approved 4mm thick veneer finish with SS hardware of approved make
Rate as per Quotes
Rate as per Shakti-Horman Nos 1.00
Rate as per JC fire door Nos 1.00 55,260.00 55,260.00
Rate as per Navair Nos 1.00 30,664.00 30,664.00
min rate 30,664.00
12 mm thick marine plywood conforming to IS: 710 8724 Sqm 3.60 785.00 2,826.00
4 mm thick approved veneer finish with adhesive MKT Sqm 3.60 2,250.00 8,100.00
Total-A 41,590.00
LABOUR MKT Sqm 1.00 1,500.00 1,500.00
Total 43,093.00
RA-123 3.28 Door (Type-7B) D-F-1F-05 (Location : Service passage), sigle leaf, size 1200mm x 2400mm, with double equal leaves door shutter (600mm + 600mm) with SS hardware of approved make
Rate as per Quotes
Rate as per Shakti-Horman Nos 1.00
Rate as per JC fire door Nos 1.00 65,500.00 65,500.00
Rate as per Navair Nos 1.00 25,099.60 25,099.60
Min + CPOH 29,153.19
RA-124 3.28 Door (Type-3) D-F-1F-12 (Location VIP Lounge-Entry), overall size 3000mm x 2400mm, with double equal leaf door shutter (900mm + 900mm) with 12mm thick Plywood backing on one side of the door finish with approved 4mm thick veneer finish with SS hardware of approved make
Rate as per Quotes
Rate as per Shakti-Horman Nos 1.00
Rate as per JC fire door Nos 1.00 75,360.00 75,360.00
Rate as per Navair Nos 1.00 46,454.80 46,454.80
min rate 46,454.80
12 mm thick marine plywood conforming to IS: 710 8724 Sqm 7.20 785.00 5,652.00
4 mm thick approved veneer finish with adhesive MKT Sqm 7.20 2,250.00 16,200.00
Total-A 68,306.80
LABOUR MKT Sqm 1.00 1,500.00 1,500.00
Total 69,809.00
RA-125 3.28 Door (DS-1) DS-F-1F-01 (Location : Electrical Shaft), sigle leaf, size 900mm x 1800mm, with SS hardware of approved make
Rate as per Quotes
Rate as per Shakti-Horman Nos 1.00
Rate as per JC fire door Nos 1.00 13,360.00 13,360.00
Rate as per Navair Nos 1.00 15,234.40 15,234.40
Min + CPOH 15,517.64
RA-126 3.28 Door (Type-3) D-G-G-03, D-G-G-06, D-G-1F-02, D-G-1F-06, D-J-L-08 (Location : Utsah Gal-FOH, Bontiful Gujarat bridge ), overall size 3000mm x 3600mm, out of which 1800mm wide x 2400mm high openable double leaf door with 12mm thick Plywood backing on one side of the door finish with approved 4mm thick veneer finish with SS hardware of approved make
Rate as per Quotes
Rate as per Shakti-Horman Nos 1.00
Rate as per JC fire door Nos 1.00 96,360.00 96,360.00
Rate as per Navair Nos 1.00 53,737.60 53,737.60
min rate 53,737.60
12 mm thick marine plywood conforming to IS: 710 8724 Sqm 10.80 785.00 8,478.00
4 mm thick approved veneer finish with adhesive MKT Sqm 10.80 2,250.00 24,300.00
Total-A 86,515.60
LABOUR MKT Sqm 1.00 1,500.00 1,500.00
Total 88,018.00
RA-127 3.28 Door (Type-7) D-G-G-04, D-J-L-10, D-J-G-12, D-J-1F-13, D-J-2F-08, D-K-G-01, D-K-G-04, D-K-G-05, D-L-G-01, D-L-G-02 (Location : Kiosk, AV Shaft, Ticketing counter, Clock room, Service door, Security cabin), sigle leaf, size 900mm x 2400mm, with 12mm thick Plywood backing on one side of the door finish with approved 4mm thick veneer finish with SS hardware of approved make
Rate as per Quotes
Rate as per Shakti-Horman Nos 1.00
Rate as per JC fire door Nos 1.00 32,980.00 32,980.00
Rate as per Navair Nos 1.00 20,180.80 20,180.80
min rate 20,180.80
12 mm thick marine plywood conforming to IS: 710 8724 Sqm 2.16 785.00 1,695.60
4 mm thick approved veneer finish with adhesive MKT Sqm 2.16 2,250.00 4,860.00
Total-A 26,736.40
LABOUR MKT Sqm 1.00 1,500.00 1,500.00
Total 28,240.00
RA-128 3.28 Door (Type-7A) D-J-G-02 (Location : Service passage), sigle leaf, size 1200mm x 2400mm, with double unequal leaves door shutter (900mm + 300mm) with SS hardware of approved make
Rate as per Quotes
Rate as per Shakti-Horman Nos 1.00
Rate as per JC fire door Nos 1.00 36,300.00 36,300.00
Rate as per Navair Nos 1.00 26,306.80 26,306.80
Min + CPOH 30,555.35
RA-129 3.28 Door (Type-7B) D-J-1F-04, D-J-1F-06, D-J-2F-06 (Location : Service passage, Baby care), sigle leaf, size 900mm x 2400mm, with double equal leaves door shutter (450mm + 450mm) with SS hardware of approved make
Rate as per Quotes
Rate as per Shakti-Horman Nos 1.00
Rate as per JC fire door Nos 1.00 32,340.00 32,340.00
Rate as per Navair Nos 1.00 20,180.80 20,180.80
Min + CPOH 23,440.00
RA-130 3.28 Door (Type-7) D-J-G-09, D-J-4F-04 (Location : Janitor room), size 750mm x 2400mm, with Single leaf door shutters with fire rated SS hardware of approved make
Rate as per Quotes
Rate as per Shakti-Horman Nos 1.00
Rate as per JC fire door Nos 1.00 22,900.00 22,900.00
Rate as per Navair Nos 1.00 18,291.40 18,291.40
Min + CPOH 21,245.46
RA-131 3.28 Door (Type-9C) D-J-3F-06 (Location : Landing store room), sigle leaf, size 750mm x 2100mm, with 35mm thick sand stone cladding on outer face, SS hardware of approved make
Rate as per Quotes
Rate as per Shakti-Horman Nos 1.00
Rate as per JC fire door Nos 1.00 21,663.00 21,663.00
Rate as per Navair Nos 1.00 17,007.40 17,007.40
min rate 17,007.40
35mm thick Honed finished sand stone (with 25% wastage) Basic Rate Sqm 1.58 4,058.03 6,391.39
12 mm plywood backing/support MKT Sqm 1.58 785.00 1,236.38
M.S. frame and shutter structure fabrication MKT Kg 32.00 85.00 2,720.00
Adhesive, screws, fasteners & accessories MKT LS 1.00 425.00 425.00
Total-A 27,780.17
LABOUR (For Fixing Stone) MKT Sqm 1.00 2,500.00 2,500.00
Total 30,284.00
RA-132 3.28 Door (Type-7B) D-J-4F-10 (Location : Café kitchen), size 1475mm x 2400mm, with double equal leaves door shutters (737.5mm + 737.5mm) with fire rated SS hardware of approved make
Rate as per Quotes
Rate as per Shakti-Horman Nos 1.00
Rate as per JC fire door Nos 1.00 56,430.00 56,430.00
Rate as per Navair Nos 1.00 30,665.32 30,665.32
Min + CPOH 35,617.77
RA-133 3.28 Door (Type-11) D-J-4F-12 (Location : Kitchen ramp), Double leaf, size 1500mm x 2100mm, with double unequal leaves door shutter (900mm + 600mm) with SS hardware of approved make
Rate as per Quotes
Rate as per Shakti-Horman Nos 1.00
Rate as per JC fire door Nos 1.00 54,285.00 54,285.00
Rate as per Navair Nos 1.00 30,889.48 30,889.48
Min + CPOH 35,878.13
RA-134 3.28 Door (Type-7) D-N-G-01, D-FS-G-01 (Location : Security cabin) size 900mm x 2250mm, with signle leaf door shutters with fire rated SS hardware of approved make
Rate as per Quotes
Rate as per Shakti-Horman Nos 1.00
Rate as per JC fire door Nos 1.00 24,138.00 24,138.00
Rate as per Navair Nos 1.00 19,425.40 19,425.40
Min + CPOH 22,562.60
RA-135 3.28 Door D-A-L-01 (Location Server Room) & D-B-L-12 (Location : UPS bank) & D-B-M-11 (Location : BMS room) & D-B-M-12 (Location : Electrical room) & D-D-L-01 (Location : IT work room), size 1200mm x 2100mm, with double unequal leaves door shutters (900mm + 300mm) with fire rated SS hardware of approved make
Rate as per Quotes
Rate as per Shakti-Horman Nos 1.00
Rate as per JC fire door Nos 1.00 29,702.00 29,702.00
Rate as per Navair Nos 1.00 34,025.28 34,025.28
Min + CPOH 34,498.87
RA-136 3.28 Door (Type-9) D-A-G-04, D-G-G-01 (Location: AHU - Auditorium, AHU-GF Gallery), size 1800mm x 2400mm, with double unequal leaves door shutters (1200mm + 600mm) with 35mm thick sand stone fire rated SS hardware of approved make
Rate as per Quotes
Rate as per Shakti-Horman Nos 1.00
Rate as per JC fire door Nos 1.00 44,532.00 44,532.00
Rate as per Navair Nos 1.00 48,877.68 48,877.68
Min + CPOH 51,723.92
RA-137 3.28 Door D-A-G-09 (Location: Auditorium-BOH) & D-G-L-02 (Location : Fire exit lobby), size 1500mm x 2400mm, with double equal leaf door shutters (750mm + 750mm), with vision window of size 300mm x 300mm with 6mm thick fire rated glass (#9), with fire rated SS hardware of approved make
Rate as per Quotes
Rate as per Shakti-Horman Nos 1.00
Rate as per JC fire door Nos 1.00 49,520.00 49,520.00
Rate as per Navair Nos 1.00 52,944.00 52,944.00
Min + CPOH 57,517.48
RA-138 3.28 Door (Type-7B) D-B-M-13, D-G-L-03, D-G-L-14 (Location : AHU Mezz, LGF, AHU Tunnel), size 1500mm x 2400mm, with double equal leaf door shutters (750mm + 750mm), with fire rated SS hardware of approved make
Rate as per Quotes
Rate as per Shakti-Horman Nos 1.00
Rate as per JC fire door Nos 1.00 36,020.00 36,020.00
Rate as per Navair Nos 1.00 46,118.40 46,118.40
Min + CPOH 41,837.23
RA-139 3.28 Door (Type-11) D-A-G-14, D-G-L-11, D-G-G-10, D-G-1F-05, D-J-L-06, D-J-G-03, D-J-G-11, D-J-1F-01, D-J-1F-12, D-J-2F-02, D-J-2F-07, D-J-3F-05, D-J-4F-03, D-J-4F-09 (Location: Fire Escape Staircase) & Door D-A-1F-03, D-B-1F-03, D-C-1F-03 (Location: Fire Escape Staircase) & D-B-G-09 (Location : Lobby-Fire door) & D-G-L-04 (Location : Utsah Gal-Fire exit), D-G-L-10 (Location : Fire sepration door) & D-J-L-07, D-J-1F-02 (Location : Siddhi Gal-Fire exit) & D-J-2F-01, D-J-3F-09 (Location : Ramp fire exit), size 1500mm x 2400mm, with double unequal leaves door shutters (900mm + 600mm) with, with vision window of size 300mm x 300mm with 6mm thick fire rated glass (#9), fire rated SS hardware of approved make
Rate as per Quotes
Rate as per Shakti-Horman Nos 1.00
Rate as per JC fire door Nos 1.00 65,720.00 65,720.00
Rate as per Navair Nos 1.00 52,944.00 52,944.00
Min + CPOH 61,494.46
RA-140 3.28 Door (Type-9) D-A-1F-01 (Location: AHU - GAURAV GALLERY), size 1800mm x 1800mm, with double unequal leaves door shutters (1200mm + 600mm) with 35mm thick sand stone fire rated SS hardware of approved make
Rate as per Quotes
Rate as per Shakti-Horman Nos 1.00
Rate as per JC fire door Nos 1.00 33,914.00 33,914.00
Rate as per Navair Nos 1.00 40,055.76 40,055.76
Min + CPOH 39,391.11
RA-141 3.28 Door (Type-11) D-A-2F-01, D-B-L-03, D-B-M-03, D-B-M-04, D-B-G-08, D-C-G-05, D-F-L-01, D-F-L-02, D-J-B-02, D-J-L01, D-J-3F-01, D-J-3F-03 (Location: Fire Escape Staircase, Fire Exit), size 1500mm x 2100mm, with double unequal leaves door shutters (900mm + 600mm) with, with vision window of size 300mm x 300mm with with 6mm thick fire rated glass (#9), fire rated SS hardware of approved make
Rate as per Quotes
Rate as per Shakti-Horman Nos 1.00
Rate as per JC fire door Nos 1.00 63,088.00 63,088.00
Rate as per Navair Nos 1.00 49,516.20 49,516.20
Min + CPOH 57,513.07
RA-142 3.28 Door (Type-7A) D-B-L-02, D-C-L-03, D-C-L-04, D-C-L-05 , D-C-L-06, D-C-L-07, D-C-L-08, D-D-L-02, 03, 04, 05, 06, 07, 08 (Location: Chiller room, Moving tool storage, Crate storage, Shipping receiving, Transit store, Crating/Uncrating, Plinth & Panel), size 2700mm x 3000mm, with double unequal leaves door shutters (1200mm + 1500mm) with fire rated SS hardware of approved make
Rate as per Quotes
Rate as per Shakti-Horman Nos 1.00
Rate as per JC fire door Nos 1.00 66,945.00 66,945.00
Rate as per Navair Nos 1.00 59,309.04 59,309.04
Min + CPOH 68,887.45
RA-143 3.28 Door (Type-7A) D-B-L-05 (Location: Quartine room, access door), size 2700mm x 3000mm, with double unequal leaves door shutters (1200mm + 1500mm) with fire rated SS hardware of approved make
Rate as per Quotes
Rate as per Shakti-Horman Nos 1.00
Rate as per JC fire door Nos 1.00 82,845.00 82,845.00
Rate as per Navair Nos 1.00 79,715.04 79,715.04
Min + CPOH 92,589.02
RA-144 3.28 Door (Type-7B) D-B-1F-01, D-C-1F-02, D-F-1F-01, D-G-L-15, D-J-L-03, D-J-L-19, D-J-G-05, D-J-M-01, D-J-3F-04, D-J-3F-07, D-J-3F-10 (Location: AHU-Gaurav Gallery, AHU Restaurant, Pump room, AHU-Ent lobby, AHU, AHU curved ramp, AHU above floor), size 1500mm x 2100mm, with double equal leaves door shutters (750mm + 750mm) with fire rated SS hardware of approved make
Rate as per Quotes
Rate as per Shakti-Horman Nos 1.00
Rate as per JC fire door Nos 1.00 33,388.00 33,388.00
Rate as per Navair Nos 1.00 42,690.60 42,690.60
Min + CPOH 38,780.16
RA-145 3.28 Door (Type-11B) D-B-1F-07, D-J-L-22 (Location: Fire Escape Staircase), size 1200mm x 2400mm, with single leaves door shutters with, with vision window of size 300mm x 300mm with with 6mm thick fire rated glass (#9), fire rated SS hardware of approved make
Rate as per Quotes
Rate as per Shakti-Horman Nos 1.00
Rate as per JC fire door Nos 1.00 42,848.00 42,848.00
Rate as per Navair Nos 1.00 47,757.12 47,757.12
Min + CPOH 49,767.95
RA-146 3.28 Door (Type-11B) D-B-2F-08 (Location: Fire Escape Staircase), size 1200mm x 2100mm, with single leaf door shutters , with vision window of size 300mm x 300mm with with 6mm thick fire rated glass (#9), fire rated SS hardware of approved make
Rate as per Quotes
Rate as per Shakti-Horman Nos 1.00
Rate as per JC fire door Nos 1.00 40,742.00 40,742.00
Rate as per Navair Nos 1.00 35,854.08 35,854.08
Min + CPOH 41,644.51
RA-147 3.28 Door (Type-7A) D-C-L-02 (Location : Metering Kiosk), sigle leaf, size 2100mm x 1500mm, with double unequal leaves door shutter (900mm + 600mm) with SS hardware of approved make
Rate as per Quotes
Rate as per Shakti-Horman Nos 1.00
Rate as per JC fire door Nos 1.00 48,088.00 48,088.00
Rate as per Navair Nos 1.00 40,267.80 40,267.80
Min + CPOH 46,771.05
RA-148 3.28 Door (Type-11A) D-F-G-11, D-F-1F-06, D-G-L-12 (Location: Fire Escape Staircase, Tunnel Fire Exit), size 1800mm x 2400mm, with double equal leaves door shutters (900mm + 900mm) with, with vision window of size 300mm x 300mm with 6mm thick fire rated glass (#9), fire rated SS hardware of approved make
Rate as per Quotes
Rate as per Shakti-Horman Nos 1.00
Rate as per JC fire door Nos 1.00 69,932.00 69,932.00
Rate as per Navair Nos 1.00 58,130.88 58,130.88
Min + CPOH 67,519.02
RA-149 3.28 Door (Type-11) D-F-2F-01 (Location: Fire Shaft) , overall size 1500mm x 2100mm, with double unequal leaves door shutters (900mm + 600mm) with, with vision window of size 300mm x 300mm with 6mm thick fire rated glass (#9), fire rated SS hardware of approved make
Rate as per Quotes
Rate as per Shakti-Horman Nos 1.00
Rate as per JC fire door Nos 1.00 63,088.00 63,088.00
Rate as per Navair Nos 1.00 39,205.80 39,205.80
Min + CPOH 45,537.54
RA-150 3.28 Door (Type-7B) D-G-1F-03 (Location: AHU), size 1800mm x 2400mm, with double equal leaves door shutters (900mm + 900mm) with fire rated SS hardware of approved make
Rate as per Quotes
Rate as per Shakti-Horman Nos 1.00
Rate as per JC fire door Nos 1.00 53,732.00 53,732.00
Rate as per Navair Nos 1.00 51,305.28 51,305.28
Min + CPOH 59,591.08
RA-151 3.28 Door (Type-7B) D-J-B-01, D-J-B-07 (Location: Pump room), size 2100mm x 2400mm, with double equal leaves door shutters (1050mm + 1050mm) with fire rated SS hardware of approved make
Rate as per Quotes
Rate as per Shakti-Horman Nos 1.00
Rate as per JC fire door Nos 1.00 57,944.00 57,944.00
Rate as per Navair Nos 1.00 52,748.16 52,748.16
Min + CPOH 61,266.99
RA-152 3.28 Door (Type-7A) D-J-B-03 (Location: Staircase), size 1200mm x 2100mm, with double eunqual leaves door shutters (900mm + 300mm) with fire rated SS hardware of approved make
Rate as per Quotes
Rate as per Shakti-Horman Nos 1.00
Rate as per JC fire door Nos 1.00 32,643.00 32,643.00
Rate as per Navair Nos 1.00 44,941.68 44,941.68
Min + CPOH 37,914.84
RA-153 3.28 Door (Type-7A) D-J-B-04, D-J-B-05, D-J-B-06 (Location: LT panel area, DG area), size 1500mm x 2100mm, with double unequal leaves door shutters (900mm + 600mm) with fire rated SS hardware of approved make
Rate as per Quotes
Rate as per Shakti-Horman Nos 1.00
Rate as per JC fire door Nos 1.00 46,888.00 46,888.00
Rate as per Navair Nos 1.00 38,675.40 38,675.40
Min + CPOH 44,921.48
RA-154 3.28 Door (Type-7) D-J-L-09 (Location: Lift lobby), size 1250mm x 3600mm, with single door shutters with 12mm thick Plywood backing on one side of the door finish with approved 4mm thick veneer finish with fire rated SS hardware of approved make
Rate as per Quotes
Rate as per Shakti-Horman Nos 1.00
Rate as per JC fire door Nos 1.00 46,825.00 46,825.00
Rate as per Navair Nos 1.00 44,941.92 44,941.92
Min + CPOH 52,200.04
RA-155 3.28 Door (Type-7) D-J-L-11 (Location: Lift lobby), size 1200mm x 3600mm, with single equal leaves door shutters , with fire rated SS hardware of approved make
Rate as per Quotes
Rate as per Shakti-Horman Nos 1.00
Rate as per JC fire door Nos 1.00 45,772.00 45,772.00
Rate as per Navair Nos 1.00 44,941.92 44,941.92
Min + CPOH 52,200.04
RA-156 3.28 Door (Type-7A) D-J-3F-08 (Location: Lift lobby), size 1500mm x 2400mm, with double eunqual leaves door shutters (900mm + 600mm) with fire rated SS hardware of approved make
Rate as per Quotes
Rate as per Shakti-Horman Nos 1.00
Rate as per JC fire door Nos 1.00 49,520.00 49,520.00
Rate as per Navair Nos 1.00 40,982.40 40,982.40
Min + CPOH 47,601.06
RA-157 3.28 Door (Type-7) D-J-3F-11 (Location: Service passage), size 900mm x 2100mm, with single leaves door shutters with fire rated SS hardware of approved make
Rate as per Quotes
Rate as per Shakti-Horman Nos 1.00
Rate as per JC fire door Nos 1.00 24,057.00 24,057.00
Rate as per Navair Nos 1.00 26,027.16 26,027.16
Min + CPOH 27,942.21
RA-158 3.28 Door (Type-DS3) DS-A-L-02, DS-G-G-01, DS-G-1F-01 (Location Fire Shaft), size 900mm x 1500mm, with double unequal leaves door shutters (600mm + 300mm) with fire rated SS hardware of approved make
Rate as per Quotes
Rate as per Shakti-Horman Nos 1.00
Rate as per JC fire door Nos 1.00 14,495.00 14,495.00
Rate as per Navair Nos 1.00 20,391.00 20,391.00
Min + CPOH 16,835.94
RA-159 3.28 Door (Type-11) D-A-M-01, D-J-L-12, D-J-L-13 (Location Mezzanine Fire Exit, Fire Exit), size 1500mm x 2100mm, with double unequal leaves door shutters (900mm + 600mm) with vision window of size 300mm x 300mm with 6mm thick fire rated glass (#9), fire rated SS hardware of approved make
Rate as per Quotes
Rate as per Shakti-Horman Nos 1.00
Rate as per JC fire door Nos 1.00 46,415.00 46,415.00
Rate as per Navair Nos 1.00 49,516.20 49,516.20
Min + CPOH 53,911.02
RA-160 3.28 Door (Type-11) D-A-G-08 (Location Auditorium Fire Exit), size 1500mm x 2100mm, with double unequal leaves door shutters (900mm + 600mm) with vision window of size 300mm x 300mm with 6mm thick fire rated glass (#9), fire rated SS hardware of approved make
Rate as per Quotes
Rate as per Shakti-Horman Nos 1.00
Rate as per JC fire door Nos 1.00 46,415.00 46,415.00
Rate as per Navair Nos 1.00 49,516.20 49,516.20
Min + CPOH 53,911.02
RA-161 3.28 Door (Type-DS3) DS-A-G-01, DS-F-G-05, DS-F-1F-05, DS-J-G-06 , DS-J-1F-06, DS-J-2F-01, DS-J-2F-02 (Location FF Shaft), size 900mm x 1800mm, with double unequal leaves door shutters (600mm + 300mm) with fire rated SS hardware of approved make
Rate as per Quotes
Rate as per Shakti-Horman Nos 1.00
Rate as per JC fire door Nos 1.00 16,034.00 16,034.00
Rate as per Navair Nos 1.00 22,594.08 22,594.08
Min + CPOH 18,623.49
RA-162 3.28 Door (Type-DS3) DS-A-1F-01 (Location: Fire Shaft), size 1200mm x 1800mm, with double unequal leaves door shutters (600mm + 600mm) with fire rated SS hardware of approved make
Rate as per Quotes
Rate as per Shakti-Horman Nos 1.00
Rate as per JC fire door Nos 1.00 16,034.00 16,034.00
Rate as per Navair Nos 1.00 22,594.08 22,594.08
Min + CPOH 18,623.49
RA-163 3.28 Door (Type-DS) DS-A-1F-02 (Location: Fire Shaft), size 1200mm x 1800mm, with double leaf door shutters with fire rated SS hardware of approved make
Rate as per Quotes
Rate as per Shakti-Horman Nos 1.00
Rate as per JC fire door Nos 1.00 16,762.00 16,762.00
Rate as per Navair Nos 1.00 26,556.24 26,556.24
Min + CPOH 19,469.06
RA-164 3.28 Door (DS-1) DS-A-2F-01 (Location Fire Shaft), size 900mm x 2100mm, with single leaf door shutter with fire rated SS hardware of approved make
Rate as per Quotes
Rate as per Shakti-Horman Nos 1.00
Rate as per JC fire door Nos 1.00 15,473.00 15,473.00
Rate as per Navair Nos 1.00 26,205.96 26,205.96
Min + CPOH 17,971.89
RA-165 3.28 Door (Type-DS1) DS-B-M-01, DS-B-G-03, DS-B-1F-02, DS-C-L-01, DS-C-1F-01, DS-F-L-02, DS-F-L-03, DS-G-L-01, DS-G-L-03, DS-G-1F-02, DS-J-G-08, DS-J-3F-02 (Location : FF shaft, Plumbing shaft, HVAC shaft, FF Hose shaft), sigle leaf, size 900mm x 1500mm, with SS hardware of approved make
Rate as per Quotes
Rate as per Shakti-Horman Nos 1.00
Rate as per JC fire door Nos 1.00 12,145.00 12,145.00
Rate as per Navair Nos 1.00 21,799.80 21,799.80
Min + CPOH 14,106.42
RA-166 3.28 Door (DS-2) DS-B-G-04 (Location : FF shaft), double equal leaf, size 1200mm x 1800mm, with SS hardware of approved make
Rate as per Quotes
Rate as per Shakti-Horman Nos 1.00
Rate as per JC fire door Nos 1.00 16,762.00 16,762.00
Rate as per Navair Nos 1.00 28,958.64 28,958.64
Min + CPOH 19,469.06
RA-167 3.28 Door (Type-DS-1) DS-B-1F-04 , DS-F-L-01, DS-F-G-01, DS-F-G-03, DS-F-1F-03, DS-G-G-02. DS-J-1F-08 (Location : FF shaft, Electrical shaft, FF House shaft), single equal leaf, size 900mm x 1800mm, with SS hardware of approved make
Rate as per Quotes
Rate as per Shakti-Horman Nos 1.00
Rate as per JC fire door Nos 1.00 13,684.00 13,684.00
Rate as per Navair Nos 1.00 24,002.88 24,002.88
Min + CPOH 15,893.97
RA-168 3.28 Door (Type-DS2) DS-B-2F-01, DS-J-L-01, DS-J-L-02, DS-J-1F-01, DS-J-4F-01, DS-J-4F-02 (Location FF Shaft), size 900mm x 1800mm, with double equal leaves door shutters (450mm + 450mm) with fire rated SS hardware of approved make
Rate as per Quotes
Rate as per Shakti-Horman Nos 1.00
Rate as per JC fire door Nos 1.00 16,034.00 16,034.00
Rate as per Navair Nos 1.00 26,489.28
Min + CPOH 18,623.49
RA-169 3.28 Door (Type-11) D-C-L-09 (Location: Fire Escape Staircase), size 1800mm x 2100mm, with double unequal leaves door shutters (1200mm + 600mm) with, with vision window of size 300mm x 300mm with 6mm thick fire rated glass (#9), fire rated SS hardware of approved make
Rate as per Quotes
Rate as per Shakti-Horman Nos 1.00
Rate as per JC fire door Nos 1.00 66,206.00 66,206.00
Rate as per Navair Nos 1.00 54,090.72 54,090.72
Min + CPOH 62,826.37
RA-170 3.28 Door (Type-7) D-C-L-10, D-C-L-11 (Location : Loading bay Steps, Ramp), size 1200mm x 2100mm, with double unequal leaves door shutters (900mm + 300mm) with SS hardware of approved make
Rate as per Quotes
Rate as per Shakti-Horman Nos 1.00
Rate as per JC fire door Nos 1.00 31,524.00 31,524.00
Rate as per Navair Nos 1.00 35,474.88 35,474.88
Min + CPOH 36,615.13
RA-171 3.28 Door (Type-7A) D-E-L-01 (Location : AV store), size 200mm x 2100mm, with double unequal leaves door shutters (900mm + 300mm) with SS hardware of approved make
Rate as per Quotes
Rate as per Shakti-Horman Nos 1.00
Rate as per JC fire door Nos 1.00 31,524.00 31,524.00
Rate as per Navair Nos 1.00 35,474.88 35,474.88
Min + CPOH 36,615.13
RA-172 3.28 Door (Type-7A) DS-C-1F-02, DS-C-1F-03 (Location FF Shaft, HVAC shaft), overall size 900mm x 1500mm, with double unequal leaves door shutters (600mm + 300mm) with fire rated SS hardware of approved make
Rate as per Quotes
Rate as per Shakti-Horman Nos 1.00
Rate as per JC fire door Nos 1.00 14,495.00 14,495.00
Rate as per Navair Nos 1.00 20,391.00 20,391.00
Min + CPOH 16,835.94
RA-173 3.28 Door (Type-7) DS-C-G-04 (Location: FF shaft), size 1200mm x 1800mm, with double equal leaves door shutters (600mm + 600mm) with 35mm thick sand stone fire rated SS hardware of approved make
Rate as per Quotes
Rate as per Shakti-Horman Nos 1.00
Rate as per JC fire door Nos 1.00 19,112.00 19,112.00
Rate as per Navair Nos 1.00 26,556.24 26,556.24
Min + CPOH 22,198.59
RA-174 3.28 Door (Type-7B) D-E-1F-01, (Location: AHU-1F), size 1500mm x 2100mm, with double equal leaves door shutters (750mm + 750mm) with fire rated SS hardware of approved make
Rate as per Quotes
Rate as per Shakti-Horman Nos 1.00
Rate as per JC fire door Nos 1.00 37,215.00 37,215.00
Rate as per Navair Nos 1.00 40,049.40 40,049.40
Min + CPOH 43,225.22
RA-175 3.28 Door (Type-DS1) DS-F-G-02, DS-F-1F-02, DS-J-G-07 (Location: Plumbing Shaft), size 600mm x 1800mm, with single leaf door shutters with fire rated SS hardware of approved make
Rate as per Quotes
Rate as per Shakti-Horman Nos 1.00
Rate as per JC fire door Nos 1.00 10,606.00 10,606.00
Rate as per Navair Nos 1.00 16,846.32 16,846.32
Min + CPOH 12,318.87
RA-176 3.28 Door (Type-DS1) DS-G-L-04, DS-G-G-06, DS-G-1F-03, DS-J-L-06, DS-J-L-07, DS-J-L-08, DS-J-G-02, DS-J-G-03, DS-J-G-04, DS-J-1F-02, DS-J-1F-03, DS-J-1F-04 (Location: HVAC Shaft, Electrical shaft, DG shaft), size 600mm x 1500mm, with single leaf door shutters with fire rated SS hardware of approved make
Rate as per Quotes
Rate as per Shakti-Horman Nos 1.00
Rate as per JC fire door Nos 1.00 9,580.00 9,580.00
Rate as per Navair Nos 1.00 14,936.40 14,936.40
Min + CPOH 11,127.17
RA-177 3.28 Door (Type-DS-1A) DS-G-G-04 (Location PHE Shaft), sigle leaf, size 600mm x 1800mm, with 35mm thick sand stone cladding on outer face, SS hardware of approved make
Rate as per Quotes
Rate as per Shakti-Horman Nos 1.00
Rate as per JC fire door Nos 1.00 10,606.00 10,606.00
Rate as per Navair Nos 1.00 16,527.12 16,527.12
Min + CPOH 12,318.87
RA-178 3.28 Door (Type-DS1) DS-G-G-05 (Location : FF + HVAC Shaft), sigle leaf, size 900mm x 1800mm, with 35mm thick sand stone cladding on outer face, SS hardware of approved make
Rate as per Quotes
Rate as per Shakti-Horman Nos 1.00
Rate as per JC fire door Nos 1.00 10,606.00 10,606.00
Rate as per Navair Nos 1.00 20,489.28 20,489.28
Min + CPOH 12,318.87
RA-179 3.28 Door (Type-10) D-G-1F-07 (Location : Landscape service, single equal leaf, size 900mm x 1800mm, with SS hardware of approved make
Rate as per Quotes
Rate as per Shakti-Horman Nos 1.00
Rate as per JC fire door Nos 1.00 22,234.00 22,234.00
Rate as per Navair Nos 1.00 23,824.08 23,824.08
Min + CPOH 25,824.79
RA-180 3.28 Door (Type-DS1) DS-J-L-05 (Location: FF Shaft), size 900mm x 2400mm, with single leaf door shutters with fire rated SS hardware of approved make
Rate as per Quotes
Rate as per Shakti-Horman Nos 1.00
Rate as per JC fire door Nos 1.00 16,762.00 16,762.00
Rate as per Navair Nos 1.00 25,274.64 25,274.64
Min + CPOH 19,469.06
RA-181 3.28 Door (Type-6) DS-J-2F-04 (Location: FF Shaft), size 900mm x 2400mm, with single leaf door shutters with 12mm thick Plywood backing on one side of the door finish with approved 4mm thick veneer finish with fire rated SS hardware of approved make
Rate as per Quotes
Rate as per Shakti-Horman Nos 1.00
Rate as per JC fire door Nos 1.00 16,762.00 16,762.00
Rate as per Navair Nos 1.00 25,274.64 25,274.64
min rate 16,762.00
12 mm thick marine plywood conforming to IS: 710 8724 Sqm 2.16 785.00 1,695.60
4 mm thick approved veneer finish with adhesive MKT Sqm 2.16 2,250.00 4,860.00
Total-A 23,317.60
LABOUR MKT Sqm 1.00 1,500.00 1,500.00
Total 24,818.00
RA-182 3.28 Door (Type-DS1) DS-J-1F-10 (Location : FF Shaft), sigle leaf, size 900mm x 2400mm, with 12mm thick Plywood backing on one side of the door finish with approved 4mm thick veneer finish with SS hardware of approved make
Rate as per Quotes
Rate as per Shakti-Horman Nos 1.00
Rate as per JC fire door Nos 1.00 16,762.00 16,762.00
Rate as per Navair Nos 1.00 25,274.64 25,274.64
Min + CPOH 19,469.06
RA-183 3.28 Door (Type-DS2) DS-J-3F-01 (Location Fire Shaft), size 900mm x 1500mm, with double equal leaves door shutters (450mm + 450mm) with fire rated SS hardware of approved make
Rate as per Quotes
Rate as per Shakti-Horman Sqm 1.00
Rate as per JC fire door Sqm 1.00 14,495.00 14,495.00
Rate as per Navair Sqm 1.00 19,894.20 19,894.20
Min + CPOH 16,835.94
RA-184 3.28 Designing, providing, fixing electrically operated galvanized rolling shutters made from nominal 75mm wide interlocking laths. Sections of minimum 18 gauge. Shutters are divided for opening as per detailed. Further to include endlocks, windlocks and angles at bottom of curtain, curtain guides, hood etc. all of G.I. and roller shaft, counterbalance balance mechanism, brackets of steel all anti - corrosion treated. Mechanism to operate with electrical motors at rate of approximately 300mm/sec. Further to have arrangement for manual operating by crane / chain in case of power failure.
GI Shutters non-perforated fire rated RS-A-1F-01 size 2500mm x 5900mm (motor operated) (Location : RS Gaurav Gal)
Rate as per Quotes
Rate as per Shakti-Horman Nos 1.00 162,471.00 162,471.00
Rate as per Gandhi Automation Nos 1.00 122,000.00 122,000.00
Rate as per Avians Nos 1.00 133,300.00 133,300.00
Min + CPOH 141,703.00
RA-185 3.28 GI Shutters non-perforated fire rated RS-B-1F-01 size 3100mm x 5900mm (motor operated) (Location : Fire COMPRT RS)
Rate as per Quotes
Rate as per Shakti-Horman Nos 1.00 353,736.00 353,736.00
Rate as per Gandhi Automation Nos 1.00 137,000.00 137,000.00
Rate as per Avians Nos 1.00 154,300.00 154,300.00
Min + CPOH 159,125.50
RA-186 3.28 GI Shutters 80% perforated fire rated RS-C-L-01 size 1800mm x 2100mm (motor operated) (Location : Waste Management)
Rate as per Quotes
Rate as per Shakti-Horman Nos 1.00 76,638.00 76,638.00
Rate as per Gandhi Automation Nos 1.00 67,000.00 67,000.00
Rate as per Avians Nos 1.00 71,000.00 71,000.00
Min + CPOH 77,820.50
RA-187 3.28 GI Shutters Single skin non-insulated fire rated RS-C-L-02 size 1800mm x 2100mm (motor operated) (Location : Loading bay)
Rate as per Quotes
Rate as per Shakti-Horman Nos 1.00 76,638.00 76,638.00
Rate as per Gandhi Automation Nos 1.00 67,000.00 67,000.00
Rate as per Avians Nos 1.00 71,000.00 71,000.00
Min + CPOH 77,820.50
RA-188 3.28 GI Shutters Single skin non-insulated fire rated RS-G-L-01 size 3000mm x 3600mm (motor operated) (Location : Fire CMPRT RS)
Rate as per Quotes
Rate as per Shakti-Horman Nos 1.00 191,174.00 191,174.00
Rate as per Gandhi Automation Nos 1.00 98,000.00 98,000.00
Rate as per Avians Nos 1.00 111,400.00 111,400.00
Min + CPOH 113,827.00
RA-189 3.28 GI Shutters 80% perforated RS-J-B-01, RS-J-B-02 size 4000mm x 3250mm (motor operated) (Location : LT panel, DG)
Rate as per Quotes
Rate as per Shakti-Horman Nos 1.00 127,358.00 127,358.00
Rate as per Gandhi Automation Nos 1.00 112,000.00 112,000.00
Rate as per Avians Nos 1.00 123,600.00 123,600.00
Min + CPOH 130,088.00
RA-190 3.28 GI Shutters 80% perforated RS-J-B-03, RS-J-B-04 size 4000mm x 5200mm (motor operated) (Location : DG)
Rate as per Quotes
Rate as per Shakti-Horman Nos 1.00 174,825.00 174,825.00
Rate as per Gandhi Automation Nos 1.00 145,000.00 145,000.00
Rate as per Avians Nos 1.00 175,300.00 175,300.00
Min + CPOH 168,417.50
RA-191 3.28 GI Shutters Single skin non-insulated fire rated RS-J-L-01 size 4500mm x 4800mm (motor operated) (Location : Fire rated Comparatmentalization)
Rate as per Quotes
Rate as per Shakti-Horman Nos 1.00 399,253.00 399,253.00
Rate as per Gandhi Automation Nos 1.00 148,000.00 148,000.00
Rate as per Avians Nos 1.00 181,100.00 181,100.00
Min + CPOH 171,902.00
RA-192 3.28 GI Shutters 80% perforated RS-J-L-02, RS-J-L-03 size 2400mm x 2100mm (motor operated) (Location : Gas bank)
Rate as per Quotes
Rate as per Shakti-Horman Nos 1.00 160,287.00 160,287.00
Rate as per Gandhi Automation Nos 1.00 73,000.00 73,000.00
Rate as per Avians Nos 1.00 77,700.00 77,700.00
Min + CPOH 84,789.50
RA-193 3.28 GI Shutters 80% perforated RS-J-L-04, size 3550mm x 2100mm (motor operated) (Location : Gas bank)
Rate as per Quotes
Rate as per Shakti-Horman Nos 1.00 209,055.00 209,055.00
Rate as per Gandhi Automation Nos 1.00 90,000.00 90,000.00
Rate as per Avians Nos 1.00 95,100.00 95,100.00
Min + CPOH 104,535.00
RA-194 3.28 GI Shutters Non perforated RS-K-G-01, size 2725mm x 1800mm (motor operated) (Location : RS ticketing counter)
Rate as per Quotes
Rate as per Shakti-Horman Nos 1.00 85,092.00 85,092.00
Rate as per Gandhi Automation Nos 1.00 77,000.00 77,000.00
Rate as per Avians Nos 1.00 209,800.00 209,800.00
Min + CPOH 89,435.50
RA-195 3.28 GI Shutters 80% perforated RS-K-G-02,03, size 1400mm x 1800mm (motor operated) (Location : RS clock room)
Rate as per Quotes
Rate as per Shakti-Horman Nos 1.00
Rate as per Gandhi Automation Nos 1.00 66,000.00 66,000.00
Rate as per Avians Nos 1.00 119,200.00 119,200.00
Min + CPOH 76,659.00
RA-196 Providing, fabricating and fixing in position Thresholds below doors as per A-13 series drawings, schedules in A-13-15 & 16 and as detailed in drawing A-13-20, made out of Stainless steel 304 grade plates, angles as per drawing to the entire satisfaction of the EIC.
Detail of 1 Rmt. 1 Rmt
Stainless Steel 304 grade plates/flats/angles MKT Kg 4.50 350.00 1,575.00
SS screws, anchor fasteners & accessories MKT LS 1.00 95.00 95.00
Sealant, packing & bedding compound MKT LS 1.00 45.00 45.00
Cutting, bending & welding charges MKT LS 1.00 145.00 145.00
Total A 1,860.00
C Add for water charges On A+B 2,210.00 1.00% 22.10
D Total A + B + C = D D 2,232.10
E Add GST Excluded On D 0.00 0.00
F Sub Total F D+E 2,232.10
G Add Contractor's OH & Profit @ 15% On F 2,232.10 15.00% 334.82
H Sub Total H E+F 2,566.92
K Total Cost per 1 Rmt H+J 2,592.58
Rate per Rmt 2,595.00
Detail of 1 Rmt. 1 Rmt
Stainless Steel 304 grade plates/flats/angles MKT Kg 2.50 350.00 875.00
SS screws, anchor fasteners & accessories MKT LS 1.00 95.00 95.00
Sealant, packing & bedding compound MKT LS 1.00 45.00 45.00
Cutting, bending & welding charges MKT LS 1.00 145.00 145.00
Total A 1,160.00
C Add for water charges On A+B 1,510.00 1.00% 15.10
D Total A + B + C = D D 1,525.10
E Add GST Excluded On D 0.00 0.00
F Sub Total F D+E 1,525.10
G Add Contractor's OH & Profit @ 15% On F 1,525.10 15.00% 228.77
H Sub Total H E+F 1,753.87
K Total Cost per 1 Rmt H+J 1,771.40
Rate per Rmt 1,775.00
RA-198 Type-4 with EPDM rubber seal gasket
Detail of 1 Rmt. 1 Rmt
Stainless Steel 304 grade plates/flats/angles MKT Kg 5.50 350.00 1,925.00
EPDM rubber seal gasket MKT Rmt 1.00 185.00 185.00
SS screws, anchor fasteners & accessories MKT LS 1.00 110.00 110.00
Sealant, packing & bedding compound MKT LS 1.00 55.00 55.00
Cutting, bending & welding charges MKT LS 1.00 165.00 165.00
Total A 2,440.00
C Add for water charges On A+B 2,890.00 1.00% 28.90
D Total A + B + C = D D 2,918.90
E Add GST Excluded On D 0.00 0.00
F Sub Total F D+E 2,918.90
G Add Contractor's OH & Profit @ 15% On F 2,918.90 15.00% 437.84
H Sub Total H E+F 3,356.74
K Total Cost per 1 Rmt H+J 3,390.30
Rate per Rmt 3,395.00
Detail of 1 Rmt. 1 Rmt
Stainless Steel 304 grade plates/flats/angles MKT Kg 1.10 350.00 385.00
SS screws, anchor fasteners & accessories MKT LS 1.00 95.00 95.00
Sealant, packing & bedding compound MKT LS 1.00 45.00 45.00
Cutting, bending & welding charges MKT LS 1.00 145.00 145.00
C Add for water charges On A+B 1,020.00 1.00% 10.20
D Total A + B + C = D D 1,030.20
E Add GST Excluded On D 0.00 0.00
F Sub Total F D+E 1,030.20
G Add Contractor's OH & Profit @ 15% On F 1,030.20 15.00% 154.53
H Sub Total H E+F 1,184.73
K Total Cost per 1 Rmt H+J 1,196.58
Rate per Rmt 1,200.00
Detail of 1 Rmt. 1 Rmt
Stainless Steel 304 grade box/channel/plate sections MKT Kg 6.50 350.00 2,275.00
SS screws, anchor fasteners & accessories MKT LS 1.00 145.00 145.00
Sealant, packing & bedding compound MKT LS 1.00 65.00 65.00
Cutting, bending & welding charges MKT LS 1.00 210.00 210.00
Total A 2,695.00
C Add for water charges On A+B 3,080.00 1.00% 30.80
D Total A + B + C = D D 3,110.80
E Add GST Excluded On D 0.00 0.00
F Sub Total F D+E 3,110.80
G Add Contractor's OH & Profit @ 15% On F 3,110.80 15.00% 466.62
H Sub Total H E+F 3,577.42
K Total Cost per 1 Rmt H+J 3,613.19
Rate per Rmt 3,615.00
Detail of 1 Rmt. 1 Rmt
Stainless Steel 304 grade box/channel/plate sections MKT Kg 4.10 350.00 1,435.00
SS screws, anchor fasteners & accessories MKT LS 1.00 145.00 145.00
Sealant, packing & bedding compound MKT LS 1.00 65.00 65.00
Cutting, bending & welding charges MKT LS 1.00 210.00 210.00
Total A 1,855.00
C Add for water charges On A+B 2,240.00 1.00% 22.40
D Total A + B + C = D D 2,262.40
E Add GST Excluded On D 0.00 0.00
F Sub Total F D+E 2,262.40
G Add Contractor's OH & Profit @ 15% On F 2,262.40 15.00% 339.36
H Sub Total H E+F 2,601.76
K Total Cost per 1 Rmt H+J 2,627.78
Rate per Rmt 2,630.00
RA-202 Providing and fixing mineral fibre false ceiling tiles at all heights of size 595X595mm of approved texture, design and pattern. The tiles should have Humidity Resistance (RH) of 99%, Light Reflectance > 85%, Thermal Conductivity k = 0.052 - 0.057 w/m K, Fire Performance as per (BS 476 pt - 6 &7)in true horizontal level suspended on interlocking T-Grid of hot dipped all round galvanized iron section of 0.33 mm thick (galvanized @120 gsm) comprising of main T runners of 15x32 mm of length 3000 mm, cross T of size 15x32mm of length 1200 mm and secondary intermediate cross T of size 15x32 mm of length 600 mm to form grid module of size 600x600 mm suspended from ceiling using galvanized mild steel item (galvanised@80gsm) 50 mm long 8mm outer diameter M-6 dash fasteners, 6 mm diameter fully threaded hanger rod up to 1000 mm length and L-shape level adjuster of size 85x25x2 mm, spaced at 1200 mm centre to centre along main ‘T’. The system should rest on periphery walls /partitions with the help of GI perimeter wall angle of size24x24X3000 mm made of 0.40 mm thick sheet, to be fixed to the wall with help of plastic rawl plug at 450 mm centre to centre & 40 mm long dry wall S.S. screws. The exposed bottom portion of all T-sections used in false ceiling support system shall be pre-painted with polyester baked paint, for all heights. The work shall be carried out as per specifications, drawings and as per directions of the Engineer-incharge.(Refer-A12-07 & 2/A14-04)
With 12.5 mm thick beveled tegular mineral fibre false ceiling tile (NRC 0.7)
Details of cost for 100 sqm 100 Sqm
Mineral fiber veveled tegular edged ceiling ties 595 x 595mm, 12.5mm thick Area = 100 sqm +5 sqm (Add for waistage @5%) 8552 / Prorata Sqm 105.00 720.00 75,600.00 16 920
G.I main runner 15x32mm of 3000mm length, 0.33mm thick including 10% waistage 8555 Each 29.50 142.00 4,189.00 12.5 718.75
G.I main runner 15x32mm of 1200mm length, 0.33mm thick including 10% waistage 8556 Each 147.00 57.00 8,379.00
G.I main runner 15x32mm of 600mm length, 0.33mm thick including 10% waistage 8557 Each 147.00 29.00 4,263.00
Galvanised steel perimeter wall angle size 24 x 24 x 0.40mm (3.00 meter long) including 10 % waistage 8591 Each 13.50 114.00 1,539.00
Galvanised iron hanger rod 6mm dia fully threaded upto 1000mm length 8558 Each 72.00 17.00 1,224.00
Galvanised MS L-shape level adjuster of size 85x25x2mm 8619 Each 72.00 18.00 1,296.00
Galvanised MS 8mm outer diameter M-6 dash fastener 50mm long 8515 Each 72.00 50.00 3,600.00
40mm long S.S screws with plastic rawl plugs 8211 100 Nos 1.00 270.00 270.00
Sundries i.e scaffolding etc 9999 LS 187.95 2.27 426.65
Carriage of material etc. 9977 LS 89.35 2.27 202.82
Total A 100,989.47
Carpenter 1st class 0111 day 28.00 897.00 25,116.00
Total B 42,044.00
C Add for water charges On A+B 143,033.47 1.00% 1430.33
D Total A + B + C = D D 144,463.81
E Add GST Excluded On D 0.00 0.00
F Sub Total F D+E 144,463.81
G Add Contractor's OH & Profit @ 15% On F 144,463.81 15.00% 21,669.57
H Sub Total H E+F 166,133.38
K Total Cost per 1 Sqm H+J 167,794.71
Rate per Sqm 1,680.00
RA-203 3.28 Providing and Fixing Channelled Woodworks perforated panels of width 192mm, thickness of 15mm and length 2400 mm, made of a Moisture resistant fibre board substrate with a laminated facing as per the approved shade (Portland Maple, Sea Beech, Siam Wood & Mystique Walnut, Interior White, Alumina Pearl) and a melamine balancing layer on the reverse side. The boards shall have a special perforation pattern where the reverse surface has a “Helmholtz” fluted perforation with consecutive 3mm wide groove followed by 13mm of visible pane. The edges of the panel shall be “tongue-and-grooved” to fix special clips for installation and seamless visual. The back of the perforated panel shall have sound absorbing non-woven Soundtex acoustical fleece hot pressed to achieve NRC of 0.6. (Average value of Absorption Co-efficient readings taken at 250 Hz, 500 Hz, 1000 Hz and 2000 Hz) as per ASTM C423 and Humidity Resistance (RH) of 70% with camber limit less than 1mm/1000mm and bow less than 1mm/300mm. (Refer-A12-07 & 9/A14-04)
Rate as per Quotes
Rate as per KNAUF Sqm 1.00 5,250.00 5,250.00
Average Rate per Sqm + CPOH 6,097.88
RA-204 3.28 Providing and fixing at all heights and location, acoustic stretched fabric false ceiling system of approved make, comprising of following components and providing NRC of _____ or better, including making cut outs for electrical conduits, networking boxes etc and openings for services and making the same good all complete as per drawings, manufacture's specification and direction of engineer in charge. Frame work : Framework shall be of cold rolled steel as per IS 513, hot dipped galvanised with 120 gsm, zinc coating as per IS 277 (both side inclusive), consisting of ceiling C-channels having web width of 50 mm, equal flanges of 32 mm and sectional thickness of 0.5 mm (+-/0.05 mm), fixed to ceiling with suitable fasteners including providing additional stud channels at openings and junctions as required as well as at locations of vertical grippers. The frame is fixed on 80mm thick plywood partition made out of 15mm thick marine grade plywood fixed on 50mm x 50mm aluminium subframe and 112mm x 50mm high 2nd quality approved teak wood wooden edge. Fabric layer: Fire retardant Fabric in approved shade, colour and texture and having minimum density 200 GSM, conforming to fire class 1 as per BS 476 part 7 and P as per BS 476 part or equivalent, is stretched, tucked and secured into the grippers in maximum possible panel sizes as approved, to obtain smooth, taut & wrinkle-free finish, with the weft and weave of the fabric in all panels oriented in one direction to achieve uniform shade. (Drg-A12-07 & 20/A14-04)
Rate as per Quotes
Rate as per BERRISOL & ILLUSION DECORS Nos 1.00 16,750.00 16,750.00
Average Rate per Sqm + CPOH 19,455.13
RA-208 Designing, fabricating, testing, installing and fixing in position polyester powder coated Aluminium plank (900mm wide) false ceiling with 3mm thick Aluminium sheet, with open grooves for linear as well as curvilinear portions of the building, for all heights and all levels etc. The fastening brackets of Aluminium alloy 6005 T5 / MS with Hot Dip Galvanised with serrations and serrated washers to arrest the wind load movement, fasteners, SS 316 Pins and anchor bolts of approved make in SS 316, Nylon separators to prevent bi-metallic contacts all complete required to perform as per specification and drawing. The item includes cost of all material & labour component, preparation detailed shop drawings with prior approval from Architect, the cost of all mock ups at site etc. complete including preparing shop drawings with prior approval of Architect / Engineer in charge etc. complete. (Refer -A12-07 & 4/A14-04)
Aluminium plank of size : 900mm x 1500mm Location : Ticketing Plaza
Details of cost for 1 sqm 1 Sqm
3 mm thick polyester powder coated aluminium sheet MKT Kg 8.54 750.00 6,402.38
15 mm thick plywood backing MKT Sqm 1.05 950.00 997.50
G.I./Aluminium framework MKT Kg 6.50 95.00 617.50
Z clips, cleats, brackets & nylon separators MKT LS 1.00 285.00 285.00
SS 316 fasteners, anchor bolts & pins MKT LS 1.00 365.00 365.00
Cutting, bending, grooving & fabrication charges MKT LS 1.00 530.00 530.00
Shop drawings, mock-up & testing charges MKT LS 1.00 285.00 285.00
Sealant, touch-up and accessories MKT LS 1.00 150.00 150.00
Total A 9,632.38
Total B 2,400.00
C Add for water charges On A+B 12,032.38 1.00% 120.32
D Total A + B + C = D D 12,152.70
E Add GST Excluded On D 0.00 0.00
F Sub Total F D+E 12,152.70
G Add Contractor's OH & Profit @ 15% On F 12,152.70 15.00% 1,822.90
H Sub Total H E+F 13,975.60
K Total Cost per 1 Sqm H+J 14,115.36
Rate per Sqm 14,120.00
RA-205 Providing and fixing roofing of approved designed for installation by mechanically attaching panels to supports using concealed clips and interconnecting side edges of adjacent panels, flashing, ridges, coves, etc. manufactured out of 0.58mm. [total coated thickness (TCT)] siliconised polyester coated cold rolled high strength steel having 275MPa, yield strength sheet to have 150gms/m2 zinc aluminum alloy coating mass or equivalent approved, the weathering surface to be given a finish coat in approved shade and colour, of 20micron SMP paint over 5 micron polyster back coat over 5 micron primer and conversion coat. The rear side to have a neutral backing of epoxy primer coat of 5 micron over 5 micron polyster back coat over 5 micron primer and conversion coat, on covered walk way including insulation & calcium silicate board at bottom, painted with enamel paint system with primer etc. all complete. (Location : Walkway Refer A16-12)
Details of cost for 1 sqm 1 Sqm
0.58 mm standing seam roofing sheet MKT Sqm 1.15 1,950.00 2,242.50
Concealed clips & accessories LS 1.00 180.00 180.00
Flashings, ridges & trims LS 1.00 250.00 250.00
Glass wool insulation 50 mm Sqm 1.05 550.00 577.50
12 mm Calcium Silicate Board Sqm 1.05 650.00 682.50
GI/MS support channels Sqm 3.50 95.00 332.50
Primer & enamel paint system Sqm 1.05 120.00 126.00
Screws, sealants & consumables LS 1.00 125.00 125.00
Total A 4,516.00
Total B 1,250.00
C Add for water charges On A+B 5,766.00 1.00% 57.66
D Total A + B + C = D D 5,823.66
E Add GST Excluded On D 0.00 0.00
F Sub Total F D+E 5,823.66
G Add Contractor's OH & Profit @ 15% On F 5,823.66 15.00% 873.55
H Sub Total H E+F 6,697.21
K Total Cost per 1 Sqm H+J 6,764.18
Rate per Sqm 6,765.00
RA-206 3.28 Supply and installation of ISOLATEK vermiculite cement based and ready - mix spray applied fireproof coating thickness shall be used to provide 120 mins of fire protection to structural steel members when tested in accordance with BS 476 part 20/21 or UL 263,ASTM E119 standards . Rate shall be inclusive of preparation of surface, application as per manufacturer's instructions, scaffolding & staging for height of 6m as required etc. complete.
Rate as per Quotes
Rate as per Morki item no 9.15 Sqm 1.00 1,300.00 1,300.00
Average Rate per Sqm + CPOH 1,509.95
RA-207 3.28 Supply and installation of low VOC water based Intumescent ISOLATEK WB3 coating as a fire protective treatment with coating thickness shall be designed to provide minimum 120 mins of fire protection to structural steel members consisting portal rafter and columns when tested in accordance with BS 476 part 20/21 or UL 263,ASTM E119 standards. The fire protection system shall consist of base coat(primer)fire protection coating (water based intumescent) and finish topcoat (polyurethane). Rate shall be inclusive of preparation of surface, application as per manufacturer's instructions, scaffolding & staging staging for height of 6m as required etc. complete.
Rate as per Quotes
Rate as per Morki item no 9.16 Sqm 1.00 3,500.00 3,500.00
Average Rate per Sqm + CPOH 4,065.25
Rate as per Quotes
Rate as per Thermaline Sqm 1.00 5,650.00 5,650.00
Rate as per Stronghold Sqm 1.00
Rate as per Alunova Sqm 1.00 7,500.00 7,500.00
Min + CPOH 6,562.48
Rate as per Quotes
Rate as per Thermaline Sqm 1.00 5,651.00 5,651.00
Rate as per Stronghold Sqm 1.00
Rate as per Alunova Sqm 1.00 7,500.00 7,500.00
Min + CPOH 6,563.64
Rate as per Quotes
Rate as per Thermaline Sqm 1.00 5,652.00 5,652.00
Rate as per Stronghold Sqm 1.00
Rate as per Alunova Sqm 1.00 7,500.00 7,500.00
Min + CPOH 6,564.80
Rate as per Quotes
Rate as per Thermaline Sqm 1.00 5,653.00 5,653.00
Rate as per Stronghold Sqm 1.00
Rate as per Alunova Sqm 1.00 7,500.00 7,500.00
Min + CPOH 6,565.96
Rate as per Quotes
Rate as per Thermaline Sqm 1.00 5,654.00 5,654.00
Rate as per Stronghold Sqm 1.00
Rate as per Alunova Sqm 1.00 7,500.00 7,500.00
Min + CPOH 6,567.12
Rate as per Quotes
Rate as per Thermaline Sqm 1.00 5,655.00 5,655.00
Rate as per Stronghold Sqm 1.00
Rate as per Alunova Sqm 1.00 7,500.00 7,500.00
Min + CPOH 6,568.28
Rate as per Quotes
Rate as per Thermaline Sqm 1.00 5,656.00 5,656.00
Rate as per Stronghold Sqm 1.00
Rate as per Alunova Sqm 1.00 7,500.00 7,500.00
Min + CPOH 6,569.44
Rate as per Quotes
Rate as per Thermaline Sqm 1.00 5,657.00 5,657.00
Rate as per Stronghold Sqm 1.00
Rate as per Alunova Sqm 1.00 7,500.00 7,500.00
Min + CPOH 6,570.61
Rate as per Quotes
Rate as per Thermaline Sqm 1.00 5,658.00 5,658.00
Rate as per Stronghold Sqm 1.00
Rate as per Alunova Sqm 1.00 7,500.00 7,500.00
Min + CPOH 6,571.77
Rate as per Quotes
Rate as per Thermaline Sqm 1.00 5,659.00 5,659.00
Rate as per Stronghold Sqm 1.00
Rate as per Alunova Sqm 1.00 7,500.00 7,500.00
Min + CPOH 6,572.93
Rate as per Quotes
Rate as per Thermaline Sqm 1.00 5,660.00 5,660.00
Rate as per Stronghold Sqm 1.00
Rate as per Alunova Sqm 1.00 7,500.00 7,500.00
Min + CPOH 6,574.09
Rate as per Quotes
Rate as per Thermaline Sqm 1.00 5,661.00 5,661.00
Rate as per Stronghold Sqm 1.00
Rate as per Alunova Sqm 1.00 7,500.00 7,500.00
Min + CPOH 6,575.25
Rate as per Quotes
Rate as per Thermaline Sqm 1.00 5,662.00 5,662.00
Rate as per Stronghold Sqm 1.00
Rate as per Alunova Sqm 1.00 7,500.00 7,500.00
Min + CPOH 6,576.41
Rate as per Quotes
Rate as per Thermaline Sqm 1.00 5,663.00 5,663.00
Rate as per Stronghold Sqm 1.00
Rate as per Alunova Sqm 1.00 7,500.00 7,500.00
Min + CPOH 6,577.57
Rate as per Quotes
Rate as per Thermaline Sqm 1.00 5,664.00 5,664.00
Rate as per Stronghold Sqm 1.00
Rate as per Alunova Sqm 1.00 7,500.00 7,500.00
Min + CPOH 6,578.74
Rate as per Quotes
Rate as per Thermaline Sqm 1.00 5,665.00 5,665.00
Rate as per Stronghold Sqm 1.00
Rate as per Alunova Sqm 1.00 7,500.00 7,500.00
Min + CPOH 6,579.90
Rate as per Quotes
Rate as per Thermaline Sqm 1.00 5,665.00 5,665.00
Rate as per Stronghold Sqm 1.00
Rate as per Alunova Sqm 1.00 7,500.00 7,500.00
Min + CPOH 6,579.90
RA-225 3.28 W-L-G-01 of size 1095mm x 1200mm with Single pane 8mm
Rate as per Quotes
Rate as per Thermaline Sqm 1.00 6,572.00 6,572.00
Rate as per Stronghold Sqm 1.00
Rate as per Alunova Sqm 1.00 6,500.00 6,500.00
Min + CPOH 7,549.75
RA-226 3.28 W-N-G-01 of size 600mm x 1200mm with Single pane 8mm
Rate as per Quotes
Rate as per Thermaline Sqm 1.00 6,572.00 6,572.00
Rate as per Stronghold Sqm 1.00
Rate as per Alunova Sqm 1.00 6,500.00 6,500.00
Min + CPOH 7,549.75
RA-227 3.28 W-V-G-01 of size 450mm x 1050mm with Single pane 8mm
Rate as per Quotes
Rate as per Thermaline Sqm 1.00 6,572.00 6,572.00
Rate as per Stronghold Sqm 1.00
Rate as per Alunova Sqm 1.00 6,500.00 6,500.00
Min + CPOH 7,549.75
RA-228 3.28 W-FS-G-01 of size 1350mm x 1050mm with Single pane 8mm
Rate as per Quotes
Rate as per Thermaline Sqm 1.00 6,572.00 6,572.00
Rate as per Stronghold Sqm 1.00
Rate as per Alunova Sqm 1.00 6,500.00 6,500.00
Min + CPOH 7,549.75
RA-229 3.28 W-FS-G-02 of size 600mm x 1050mm with Single pane 8mm
Rate as per Quotes
Rate as per Thermaline Sqm 1.00 6,572.00 6,572.00
Rate as per Stronghold Sqm 1.00
Rate as per Alunova Sqm 1.00 6,500.00 6,500.00
Min + CPOH 7,549.75
RA-230 3.28 W-C-1F-02A of size 1200mm x 1200mm with DGU glass type # 4: Insualted (8mm + 16mm +6mm) 30mm
Rate as per Quotes
Rate as per Thermaline Sqm 1.00 9,024.00 9,024.00
Rate as per Stronghold Sqm 1.00
Rate as per Alunova Sqm 1.00 8,950.00 8,950.00
Min + CPOH 10,395.42
RA-231 3.28 W-A-G-09 of 600mm x 2400mm DGU glass type # 1: Inuslated (6mm + 1.5mm Laminate + 6mm + 16mm Air Gap + 8mm) 37.52mm
Rate as per Quotes
Rate as per Thermaline Sqm 1.00 17,222.00 17,222.00
Rate as per Stronghold Sqm 1.00
Rate as per Alunova Sqm 1.00 13,500.00 13,500.00
Min + CPOH 15,680.25
RA-232 3.28 W-K-G-01 of size 2725mm x 1000mm DGU glass type # 4: Insualted (8mm + 16mm +6mm) 30mm
Rate as per Quotes
Rate as per Thermaline Sqm 1.00 9,024.00 9,024.00
Rate as per Stronghold Sqm 1.00
Rate as per Alunova Sqm 1.00 8,100.00 8,100.00
Min + CPOH 9,408.15
RA-233 3.28 W-K-G-02 of size 1400mm x 1000mm DGU glass type # 4: Insualted (8mm + 16mm +6mm) 30mm
Rate as per Quotes
Rate as per Thermaline Sqm 1.00 9,024.00 9,024.00
Rate as per Stronghold Sqm 1.00
Rate as per Alunova Sqm 1.00 8,100.00 8,100.00
Min + CPOH 9,408.15
RA-234 3.28 W-L-G-02 of size 1800mm x 950mm with Single pane 8mm
Rate as per Quotes
Rate as per Thermaline Sqm 1.00 6,572.00 6,572.00
Rate as per Stronghold Sqm 1.00
Rate as per Alunova Sqm 1.00 7,000.00 7,000.00
Min + CPOH 7,633.38
RA-235 3.28 W-N-G-02, W-FS-G-02 of size 1350mm x 1000mm with Single pane 8mm
Rate as per Quotes
Rate as per Thermaline Sqm 1.00 6,572.00 6,572.00
Rate as per Stronghold Sqm 1.00
Rate as per Alunova Sqm 1.00 7,000.00 7,000.00
Min + CPOH 7,633.38
RA-236 3.28 W-V-G-02 of size 1800mm x 1050mm with Single pane 8mm
Rate as per Quotes
Rate as per Thermaline Sqm 1.00 6,572.00 6,572.00
Rate as per Stronghold Sqm 1.00
Rate as per Alunova Sqm 1.00 7,000.00 7,000.00
Min + CPOH 7,633.38
RA-237 3.28 W-L-G-03 of size 2250mm x 1200mm with Single pane 8mm
Rate as per Quotes
Rate as per Thermaline Sqm 1.00 6,572.00 6,572.00
Rate as per Stronghold Sqm 1.00
Rate as per Alunova Sqm 1.00 9,900.00 9,900.00
Min + CPOH 7,633.38
RA-238 3.28 W-G-1F-21 of size 3900mm x 3000mm DGU glass type # 1: Inuslated (6mm + 1.5mm Laminate + 6mm + 16mm Air Gap + 8mm) 37.52mm
Rate as per Quotes
Rate as per Thermaline Sqm 1.00 17,222.00 17,222.00
Rate as per Stronghold Sqm 1.00
Rate as per Alunova Sqm 1.00 19,000.00 19,000.00
Min + CPOH 20,003.35
RA-239 3.28 W-J-4F-04 of size 15850mm x (1900mm at LHS + 2773mm at RHS) DGU glass type # 1: Inuslated (6mm + 1.5mm Laminate + 6mm + 16mm Air Gap + 8mm) 37.52mm
Rate as per Quotes
Rate as per Thermaline Sqm 1.00 17,222.00 17,222.00
Rate as per Stronghold Sqm 1.00
Rate as per Alunova Sqm 1.00 14,000.00 14,000.00
Min + CPOH 16,261.00
RA-240 3.28 W-G-L-14 of size (1200mm at bottom + 1620mm at top) x 2400mm DGU glass type # 1: Inuslated (6mm + 1.5mm Laminate + 6mm + 16mm Air Gap + 8mm) 37.52mm
Rate as per Quotes
Rate as per Thermaline Sqm 1.00 17,222.00 17,222.00
Rate as per Stronghold Sqm 1.00
Rate as per Alunova Sqm 1.00 19,000.00 19,000.00
Min + CPOH 20,003.35
RA-241 Designing, fabricating, testing, installing and fixing in position 5mm thick Aluminium sheet cladding, with open grooves for linear as well as curvilinear portions of the building , for all heights and all levels etc. The fastening brackets of Aluminium alloy 6005 T5 / MS with Hot Dip Galvanised with serrations and serrated washers to arrest the wind load movement, fasteners, SS 316 Pins and anchor bolts of approved make in SS 316, Nylon separators to prevent bi-metallic contacts all complete required to perform as per specification and drawing. The item includes cost of all material & labour component, preparation detailed shop drawings with prior approval from Architect, the cost of all mock ups at site, cleaning and protection of cladding till the handing over of the building for occupation. Base frame work for cladding is payable under the relevant aluminium item. Refer A14-02 Det - 12
Details of cost for 1 sqm 1 Sqm
5 mm thick aluminium sheet MKT Kg 15.00 550.00 8,250.00
Aluminium/MS brackets & cleats MKT Kg 2.50 130.00 325.00
SS 316 fasteners, pins & anchor bolts MKT LS 1.00 485.00 485.00
Nylon separators, serrated washers & accessories MKT LS 1.00 150.00 150.00
Grooving, bending & fabrication charges MKT LS 1.00 685.00 685.00
Shop drawings, mock-up & testing charges MKT LS 1.00 325.00 325.00
Cleaning, protection film & handling charges MKT LS 1.00 165.00 165.00
Total A 10,385.00
Total B 2,500.00
C Add for water charges On A+B 12,885.00 1.00% 128.85
D Total A + B + C = D D 13,013.85
E Add GST Excluded On D 0.00 0.00
F Sub Total F D+E 13,013.85
G Add Contractor's OH & Profit @ 15% On F 13,013.85 15.00% 1,952.08
H Sub Total H E+F 14,965.93
K Total Cost per 1 Sqm H+J 15,115.59
Rate per Sqm 15,120.00
Details of cost for 3 meter 3 Rmt
Rate as per Sub analysis No.16.81X 16.81X Rmt 3.00 53.70 161.10
Rate as per Sub analysis No.16.81Y 16.81Y Rmt 3.00 1,673.35 5,020.05
Rate as per item No.13.50.3 of SH: Finishing 13.50.3 Sqm 11.00 67.40 741.40
Rate as per item No.13.61.1 of SH: Finishing 13.61.1 Sqm 11.00 155.90 1,714.90
Total A 7,637.45
B LABOUR Including
C Add for water charges On A+B 7,637.45 1.00% 76.37
D Total A + B + C = D D 7,713.82
E Add GST Excluded On D 0.00 0.00
F Sub Total F D+E 7,713.82
G Add Contractor's OH & Profit @ 15% On F 7,713.82 15.00% 1,157.07
H Sub Total H E+F 8,870.90
K Total Cost per 1 Rmt H+J 8,959.61
Rate per Rmt 2,990.00
SuPr ENGINEERING & CONSULATANTS 307,SIDDHARTH UPSCALE VASANA ROAD VADODARA-390007 SUMMARY
VADODARA PROJECT : GUJARAT VANDANA MUSEUM, GUJARAT
DATE : 05-09-25 ARCHITECT : OPOLIS
PREPARED BY : d CLIENT : DIRECTORATE OF ARCHEOLOGY AND MUSEUMS, G.O.G
REV : CHECKED BY :
SR. NO. PARTICULAR UNIT Qty. Floor NO. Total QTY. WITH CONTIGENCY
1.1.11 EXCAVATION FOR PILE 600MM DIA RMT 10672.00 1.00 10672.00 11206.00
1.3 ANTITERMITE TREATMENT
RAFT SLAB LEVELFLOOR Sqm 3481.77 1.00 3481.77
Total Sqm 3481.77 3830.00
Footing level Cum 191.88 1.00 191.88
PCC BELOW RETAINING WALL(1:3:6) Cum 33.23 1.00 33.23
BELOW RAFT SLAB PCC Cum 487.40 1.00 487.40
Total Cum 712.51 749.00
250 MM THICK GRADE SLAB
Lower Ground Level Cum 530.28 1.00 530.28
Total Cum 530.28 557.00
FOOTING LEVEL Cum 870.44 1.00 870.44
Total Cum 870.44 914.00
2 STRUCTURAL WORK
2.1 CONCRETE WORK
@ Pile Concrete (M40)
Total Cum 3015.91 3167.00
@ Footing Pile Cap
Total Cum 1602.75 1683.00
@ CHIPING BREAKING PILE HEAD Cum 56.55 1.00 56.55
Total Cum 56.55 60.00
@ Raft Slab Below Retaining Wall (M40) Cum 478.15 1.00 478.15
Total Cum 478.15 503.00
UP TO GRADE SLAB Cum 107.83 1.00 107.83
RAFT SLAB LEVEL(LOWER GROUND FLOOR) Cum 222.13 1.00 222.13
MEZZANINE FLOOR Cum 173.17 1.00 173.17
GROUND FLOOR Cum 384.17 1.00 384.17
FIRST FLOOR Cum 285.69 1.00 285.69
SECOND FLOOR Cum 189.58 1.00 189.58
THIRD FLOOR Cum 17.37 1.00 17.37
Total Cum 1379.93 1449.00
@ RETAINING WALL
GRADE OF CONCRETE M40
UP TO GRADE SLAB Cum 105.44 1.00 105.44
RAFT SLAB LEVEL Cum 229.38 1.00 229.38
MEZZANINE LEVEL Cum 202.16 1.00 202.16
GROUND FLOOR LEVEL Cum 262.93 1.00 262.93
Total Cum 799.92 840.00
@ SHEAR WALL (M40)
UP TP GRADE SLAB Cum 45.68 1.00 45.68
RAFT SLAB LEVEL Cum 104.35 1.00 104.35
MEZZANINE FLOOR LVL Cum 104.75 1.00 104.75
GROUND FLOOR LVL Cum 201.95 1.00 201.95
FIRST FLOOR LVL Cum 236.50 1.00 236.50
SECOND FLOOR LVL Cum 153.67 1.00 153.67
THIRD FLOOR LVL Cum 28.64 1.00 28.64
Total Cum 875.53 920.00
@ FLOOR BEAM (M40)
RAFT SLAB LEVEL Cum 186.52 1.00 186.52
Total Cum 186.52 196.00
MEZZANINE LVL FLOOR Cum 66.96 1.00 66.96
GROUND FLOOR Cum 149.79 1.00 149.79
FIRST FLOOR Cum 128.99 1.00 128.99
SECOND FLOOR Cum 168.68 1.00 168.68
THIRD FLOOR Cum 15.34 1.00 15.34
Total Cum 529.75 557.00
@ 250 MM THICK RCC SLAB (M40)
MEZZANINE FLOOR Cum 235.72 1.00 235.72
Gorund Floor Level Cum 224.27 1.00 224.27
Total Cum 459.99 483.00
@ 150 MM THICK RCC SLAB
MEZZANINE FLOOR Cum 62.80 1.00 62.80
Ground FLOOR Cum 103.95 1.00 103.95
FIRST FLOOR Cum 70.81 1.00 70.81
SECOND FLOOR Cum 56.99 1.00 56.99
Total Cum 294.55 310.00
@ 200 MM THICK RCC SLAB
MEZZANINE FLOOR Cum 26.18 1.00 26.18
Ground FLOOR Cum 70.62 1.00 70.62
FIRST FLOOR Cum 15.75 1.00 15.75
SECOND FLOOR Cum 44.08 1.00 44.08
Total Cum 156.63 165.00
Gorund Floor Level Cum 244.10 1.00 244.10
FIRST FLOOR LEVEL Cum 386.99 1.00 386.99
SECOND FLOOR LEVEL Cum 394.96 1.00 394.96
THIRD FLOOR LEVEL Cum 109.94 1.00 109.94
Total Cum 1135.98 1193.00
Gorund Floor Level Sqm 1220.48 1.00 1220.48
FIRST FLOOR LEVEL Sqm 1934.94 1.00 1934.94
SECOND FLOOR LEVEL Cum 1974.78 1.00 1974.78
Total Cum 5130.20 5387.00
BASEMENT TO FOURTH FLOOR Cum 157.02 1.00 157.02
Total Cum 157.02 165.00
Total OF M40 GRADE Cum 8,586.99 9,017.00
GROUND FLOOR LEVEL kg 248,985.34 1.00 248,985.34
FIRST FLOOR LEVEL kg 506,245.56 1.00 506,245.56
SECOND FLOOR LEVEL kg 445,086.01 1.00 445,086.01
THIRD FLOOR LEVEL kg 211,754.37 1.00 211,754.37
@ STEEL BEAM PAINT
GROUND FLOOR LEVEL Sqm 1,793.66 1.00 1,793.66
FIRST FLOOR LEVEL Sqm 2,901.40 1.00 2,901.40
SECOND FLOOR LEVEL Sqm 2,787.30 1.00 2,787.30
THIRD FLOOR LEVEL Sqm 1,124.51 1.00 1,124.51
@ Footing Pile Cap
Total Sqm 2005.28 2206.00
@ Raft Slab Below Retaining Wall (M40)
Total Sqm 507.96 559.00
UP TO GRADE SLAB Sqm 608.34 1.00 608.34
RAFT SLAB LEVEL(LOWER GROUND FLOOR) Sqm 1252.36 1.00 1252.36
MEZZANINE FLOOR Sqm 947.54 1.00 947.54
GROUND FLOOR Sqm 2052.12 1.00 2052.12
FIRST FLOOR Sqm 1705.24 1.00 1705.24
SECOND FLOOR Sqm 1107.56 1.00 1107.56
THIRD FLOOR Sqm 114.76 1.00 114.76
Total Sqm 7787.92 8567.00
@ RETAINING WALL
UP TO GRADE SLAB Sqm 702.95 1.00 702.95
RAFT SLAB LEVEL Sqm 1529.21 1.00 1529.21
MEZZANINE LEVEL Sqm 1347.74 1.00 1347.74
GROUND FLOOR LEVEL Sqm 1752.88 1.00 1752.88
Total Sqm 5332.79 5867.00
UP TO GRADE SLAB Sqm 242.39 1.00 242.39
RAFT SLAB LEVEL Sqm 544.68 1.00 544.68
MEZZANINE FLOOR LVL Sqm 659.33 1.00 659.33
GROUND FLOOR LVL Sqm 1070.89 1.00 1070.89
FIRST FLOOR LVL Sqm 1242.83 1.00 1242.83
SECOND FLOOR LVL Sqm 831.35 1.00 831.35
THIRD FLOOR LVL Sqm 162.70 1.00 162.70
Total Sqm 4754.17 5230.00
RAFT SLAB LEVEL Sqm 1064.36 1.00 1064.36
Total Sqm 1064.36 1171.00
MEZZANINE LVL FLOOR Sqm 539.73 1.00 539.73
GROUND FLOOR Sqm 1023.52 1.00 1023.52
FIRST FLOOR Sqm 760.48 1.00 760.48
SECOND FLOOR Sqm 889.73 1.00 889.73
THIRD FLOOR Sqm 87.07 1.00 87.07
Total Sqm 3300.52 3631.00
@ 250 MM THICK RCC SLAB (M40)
MEZZANINE FLOOR Sqm 942.86 1.00 942.86
Gorund Floor Level Sqm 897.09 1.00 897.09
Total Sqm 1839.95 2024.00
@ 150 MM THICK RCC SLAB
MEZZANINE FLOOR Sqm 418.66 1.00 418.66
Ground FLOOR Sqm 692.99 1.00 692.99
FIRST FLOOR Sqm 472.09 1.00 472.09
SECOND FLOOR Sqm 379.92 1.00 379.92
Total Sqm 1963.66 2161.00
@ 200 MM THICK RCC SLAB
MEZZANINE FLOOR Sqm 130.89 1.00 130.89
Ground FLOOR Sqm 353.12 1.00 353.12
FIRST FLOOR Sqm 78.77 1.00 78.77
SECOND FLOOR Sqm 220.38 1.00 220.38
Total Sqm 783.16 862.00
Gorund Floor Level Sqm 1220.48 1.00 1220.48
FIRST FLOOR LEVEL Sqm 1934.94 1.00 1934.94
SECOND FLOOR LEVEL Sqm 1974.78 1.00 1974.78
Total Sqm 5130.20 5644.00
BASEMENT TO FOURTH FLOOR Sqm 1,035.34 1.00 1,035.34
Total Sqm 1,035.34 1139.00
3 REINFORCEMENT KG/CUM
RETAINING WALL 100.00 799.92 79991.808
SALB BEAM & MAIN BEAM 300.00 529.75 158925.1329
EXPANSION JOINT-EXTERIOR CODE-A12-13 & A11-03
2 ROOF TYPE - 1 (1-A11-03)
Basement Floor Rmt 0.00 1.00 0.00
Lower Ground Floor Rmt 0.00 1.00 0.00
Mezzanine Floor Rmt 0.00 1.00 0.00
Ground Floor Rmt 0.00 1.00 0.00
First Floor Rmt 0.00 1.00 0.00
Second Floor Rmt 0.00 1.00 0.00
Third Floor Rmt 0.00 1.00 0.00
Fourth Floor Rmt 10.72 1.00 10.72
Total Rmt 10.72 12.00
2 ROOF TYPE - 2 (2-A11-03)
Basement Floor Rmt 0.00 1.00 0.00
Lower Ground Floor Rmt 0.00 1.00 0.00
Mezzanine Floor Rmt 0.00 1.00 0.00
Ground Floor Rmt 0.00 1.00 0.00
First Floor Rmt 0.00 1.00 0.00
Second Floor Rmt 15.80 1.00 15.80
Third Floor Rmt 0.00 1.00 0.00
Fourth Floor Rmt 19.65 1.00 19.65
Total Rmt 35.45 39.00
3 ROOF TYPE - 3 (A11-03)
Basement Floor Rmt 0.00 1.00 0.00
Lower Ground Floor Rmt 13.46 1.00 13.46
Mezzanine Floor Rmt 0.00 1.00 0.00
Ground Floor Rmt 59.11 1.00 59.11
First Floor Rmt 0.00 1.00 0.00
Second Floor Rmt 6.20 1.00 6.20
Third Floor Rmt 0.00 1.00 0.00
Fourth Floor Rmt 4.25 1.00 4.25
Total Rmt 83.01 92.00
4 WALL TYPE - 1 (4-A11-03)
Basement Floor Rmt 0.00 1.00 0.00
Lower Ground Floor Rmt 0.00 1.00 0.00
Mezzanine Floor Rmt 0.00 1.00 0.00
Ground Floor Rmt 24.00 1.00 24.00
First Floor Rmt 28.80 1.00 28.80
Second Floor Rmt 0.00 1.00 0.00
Third Floor Rmt 0.00 1.00 0.00
Fourth Floor Rmt 0.00 1.00 0.00
Total Rmt 52.80 59.00
Basement Floor Rmt 0.00 1.00 0.00
Lower Ground Floor Rmt 14.40 1.00 14.40
Mezzanine Floor Rmt 19.20 1.00 19.20
Ground Floor Rmt 24.00 1.00 24.00
First Floor Rmt 21.60 1.00 21.60
Second Floor Rmt 10.20 1.00 10.20
Third Floor Rmt 0.00 1.00 0.00
Fourth Floor Rmt 0.00 1.00 0.00
Total Rmt 89.40 99.00
9.2 EXPANSION JOINT-INTERIOR CODE-A12-13 & A11-03
1 WALL TYPE-3 (5-A14-11)
Basement Floor Rmt 0.00 1.00 0.00
Lower Ground Floor Rmt 64.80 1.00 64.80
Mezzanine Floor Rmt 9.60 1.00 9.60
Ground Floor Rmt 18.00 1.00 18.00
First Floor Rmt 21.60 1.00 21.60
Second Floor Rmt 0.00 1.00 0.00
Third Floor Rmt 0.00 1.00 0.00
Fourth Floor Rmt 0.00 1.00 0.00
Total Rmt 114.00 126.00
2 FLOORING TYPE-1 (1-A14-11)
Basement Floor Rmt 0.00 1.00 0.00
Lower Ground Floor Rmt 0.00 1.00 0.00
Mezzanine Floor Rmt 0.00 1.00 0.00
Ground Floor Rmt 19.60 1.00 19.60
First Floor Rmt 8.70 1.00 8.70
Second Floor Rmt 0.00 1.00 0.00
Third Floor Rmt 0.00 1.00 0.00
Fourth Floor Rmt 0.00 1.00 0.00
Total Rmt 28.30 32.00
3 FLOORING TYPE-2 (2-A14-11)
Basement Floor Rmt 0.00 1.00 0.00
Lower Ground Floor Rmt 0.00 1.00 0.00
Mezzanine Floor Rmt 0.00 1.00 0.00
Ground Floor Rmt 18.69 1.00 18.69
First Floor Rmt 24.43 1.00 24.43
Second Floor Rmt 0.00 1.00 0.00
Third Floor Rmt 0.00 1.00 0.00
Fourth Floor Rmt 0.00 1.00 0.00
Total Rmt 43.12 48.00
4 FLOORING TYPE-3 (3-A14-11)
Basement Floor Rmt 0.00 1.00 0.00
Lower Ground Floor Rmt 0.00 1.00 0.00
Mezzanine Floor Rmt 3.42 1.00 3.42
Ground Floor Rmt 6.84 1.00 6.84
First Floor Rmt 6.84 1.00 6.84
Second Floor Rmt 1.50 1.00 1.50
Third Floor Rmt 0.00 1.00 0.00
Fourth Floor Rmt 0.00 1.00 0.00
Total Rmt 18.60 21.00
5 FLOORING TYPE-4 (4-A14-11)
Basement Floor Rmt 0.00 1.00 0.00
Lower Ground Floor Rmt 0.00 1.00 0.00
Mezzanine Floor Rmt 0.00 1.00 0.00
Ground Floor Rmt 9.51 1.00 9.51
First Floor Rmt 7.22 1.00 7.22
Second Floor Rmt 5.51 1.00 5.51
Third Floor Rmt 0.00 1.00 0.00
Fourth Floor Rmt 0.00 1.00 0.00
Total Rmt 22.24 25.00
SuPr ENGINEERING & CONSULATANT 307,SIDDHARTH UPSCALE VASANA ROAD VADODARA-390007 MEASUREMENT
VADODARA ARCHITECT:-
DATE : 24.09.2024 CLIENT:-
PREPARED BY : CHECKED BY :
SR.NO. PARTICULARS NO. L B D / H QTY.
Drg No :- Depht- 1.50 mt
Mass excavation for lower Ground floor level
Drg No :- Depht- 1.50 mt
Mass excavation for lower Ground floor level
Drg No :- Depht- 1.50 mt
Mass excavation for lower Ground floor level
Drg No :- Depht- 1.50 mt
Mass excavation for lower Ground floor level
1.1.11 EXCAVATION FOR PILE 600MM DIA
Drg No :- Depht- 16.00 mt
1.2 BACK FILLING
Drg Title :- NA
Total excavation for block B 1.0 7332.12 Qty 7332.12
Ded of pile cap -1.0 411.03 -411.03
Ded of columns -1.0 25.72 -25.72
Ded of r.wall -1.0 15.95 -15.95
Ded of retaining wall raft slab -1.0 128.28 -128.28
Ded of grade slab -1.0 214.10 -214.10
Ded of shear wall -1.0 10.73 -10.73
Total excavation for block C 1.0 2701.23 Qty 2701.23
Ded of pile cap -1.0 445.80 -445.80
Ded of columns -1.0 13.60 -13.60
Ded of r.wall -1.0 16.41 -16.41
Ded of retaining wall raft slab -1.0 108.45 -108.45
Ded of grade slab -1.0 184.98 -184.98
Ded of shear wall -1.0 8.20 -8.20
Total excavation for block D 1.0 4607.89 Qty 4607.89
Ded of pile cap -1.0 320.90 -320.90
Ded of columns -1.0 16.07 -16.07
Ded of r.wall -1.0 6.91 -6.91
Ded of retaining wall raft slab -1.0 41.73 -41.73
Ded of grade slab -1.0 166.26 -166.26
Ded of shear wall -1.0 1.17 -1.17
Deduction for pile cap from slab -1.0 1133.57 P-area 0.25 -283.39
1.2 SOIL FILLING
Drg Title :- NA
Ded of area (lvl 1.0 650.00 3.31 2151.50
Ded of pile cap -1.0 425.03 -425.03
Ded of columns -1.0 52.45 -52.45
Ded of r.wall -1.0 66.16 -66.16
Ded of retaining wall raft slab -1.0 199.68 -199.68
Ded of grade slab -1.0 248.33 -248.33
Ded of shear wall -1.0 25.58 -25.58
1.3 ANTITERMITE TREATMENT
RAFT SLAB LEVELFLOOR
Drg Title : RAFT SLAB LEVELFLOOR
BLOCK A 1.0 1055.95 P-area 1055.95
BLOCK B 1.0 914.82 P-area 914.82
BLOCK C 1.0 791.13 P-area 791.13
BLOCK D 1.0 719.87 P-area 719.87
@ FOOTING LEVEL
Drg Title :- NA
Drg No :- BGA/GVM/STR-101
@ PCC BELOW GRADE SLAB
@ FOOTING LEVEL
Drg No :- BGA/GVM/STR-02
CIRCULAR COLUMN (3.14*D) -3.0 3.14 0.85 0.15 -1.20
@ PCC BELOW RETAINING WALL(1:3:6)
@ FOOTING LEVEL
Drg No :- BGA/GVM/STR-101
1.5 250 MM THICK GRADE SLAB
Lower Ground Level
Drg Title :- NA
Drg No :- BGA/GVM/STR-101
BLOCK A 1.0 96.17 P-area 0.25 24.04
COLUMN DED -20.0 0.16 P-area 0.25 -0.79
COLUMN DED -11.0 0.16 P-area 0.25 -0.43
deduction for pile cap -1.0 1133.57 P-area 0.25 -283.39
@ FOOTING LEVEL
Drg Title :- NA
2.1 CONCRETE WORK
@ Footing Pile Cap
@ Pile Concrete (M40)
CHIPING BREAKING PILE HEAD
@ Raft Slab Below Retaining Wall (M40)
A12A,A12B Remaining Area 2.0 9.90 0.75 0.60 8.91 25.56
D1 REMAINING AREA 1.0 3.90 1.50 0.60 3.51 6.48
RCC COLUMN (M40)
UP TO RAFT SLAB LVL
Drg No :- HT 0.60
Drg No :- NA SLB THK 0.00
Drg Date:- 0.60
RAFT SLAB LEVEL(LOWER GROUND FLOOR)
Drg No :- HT 3.60
Drg No :- NA SLB THK -0.25
Drg Date:- 3.35
MEZZANINE FLOOR
Drg No :- HT 4.80
Drg No :- NA SLB THK -0.25
Drg Date:- 4.55
Drg No :- HT 6.00
Drg No :- NA SLB THK -0.25
Drg Date:- 5.75
Drg No :- HT 7.20
Drg No :- NA SLB THK -0.20
Drg Date:- 7.00
Drg No :- NA HT 4.95
Drg Date:- SLB THK -0.20
THIRD FLOOR HT 4.00
Drg No :- SLB THK -0.20
Drg No :- NA 3.80
@ RETAINING WALL
GRADE OF CONCRETE M40
RAFT SLAB LEVEL
@ RETAINING WALL
GRADE OF CONCRETE M40
RAFT SLAB LEVEL
@ RETAINING WALL
GRADE OF CONCRETE M40
MEZZANINE LEVEL
@ RETAINING WALL
GRADE OF CONCRETE M40
GROUND FLOOR LEVEL
GRADE OF CONCRETE M40
RAFT SLAB LEVEL
GRADE OF CONCRETE M40
RAFT SLAB LEVEL
GRADE OF CONCRETE M40
MEZZANINE FLOOR LVL HT 4.80
Drg Title :- SLAB -0.25
Drg No :- NA 5.05
GROUND FLOOR LVL HT 6.00
Drg Title :- SLAB -0.15
Drg No :- NA 6.15
FIRST FLOOR LVL HT 7.20
Drg Title :- SLAB -0.20
Drg No :- NA 7.40
SECOND FLOOR LVL
THIRD FLOOR LVL
@ RCC FLOOR BEAM
GRADE OF CONCRETE M40
RAFT SLAB LEVEL
MEZZANINE LVL FLOOR
Beam Depth 0.60 Beam Depth 0.80
Slab Thk. -0.20 Slab Thk. -0.20
Beam Depth 0.50 Beam Depth 0.60
Slab Thk. -0.15 Slab Thk. -0.23
Beam Depth 0.60 Beam Depth 0.60
Slab Thk. -0.25 Slab Thk. -0.15
Beam Depth 0.60 Beam Depth 0.90
Slab Thk. -0.25 Slab Thk.
Beam Depth 0.60 Beam Depth 1.00
Slab Thk. -0.20 Slab Thk.
Beam Depth 0.60 Beam Depth 0.75
Slab Thk. -0.23 Slab Thk.
Beam Depth 0.60 Beam Depth 0.80
Slab Thk. -0.15 Slab Thk.
Beam Depth 0.75 Beam Depth 0.50
Slab Thk. -0.25 Slab Thk. -0.15
Beam Depth 0.60 Beam Depth 0.75
Slab Thk. -0.15 Slab Thk. -0.15
Beam Depth 1.00
Slab Thk. -0.15
Beam Depth 0.60 Beam Depth 0.75
Slab Thk. -0.15 Slab Thk. -0.15
Beam Depth 1.00
Slab Thk. -0.15
@ 250 MM THICK RCC SLAB (M40)
MEZZANINE FLOOR
Drg Title :- 20240916_MORKI_DD
Gorund Floor Level
Drg Title :- 20240916_MORKI_DD
150 MM THICK RCC SLAB
MEZZANINE FLOOR
STAIRCASE DED -1.0 45.05 P-AREA 0.15 -6.76 -45.05
150 MM THICK RCC SLAB
STAIRCASE DED -1.0 40.54 P-AREA 0.15 -6.08 -40.54
200 MM THK SLAB DED -1.0 31.19 P-AREA 0.15 -4.68 -31.19
DECK SLAB DED -1.0 161.99 P-AREA 0.15 -24.30 -161.99
STAIRCASE DED -1.0 43.26 P-AREA 0.15 -6.49 -43.26
DECK SLAB DED -1.0 392.48 P-AREA 0.15 -58.87 -392.48
200 MM THK SLAB DED -1.0 33.29 P-AREA 0.15 -4.99 -33.29
200 MM THK SLAB DED -1.0 13.10 P-AREA 0.15 -1.97 -13.10
200 MM THK SLAB DED -1.0 63.94 P-AREA 0.15 -9.59 -63.94
200 MM THK SLAB DED -1.0 13.05 P-AREA 0.15 -1.96 -13.05
150 MM THICK RCC SLAB
STAIRCASE DED -1.0 46.28 P-AREA 0.15 -6.94 -46.28
150 MM THICK RCC SLAB
200 MM THICK RCC SLAB
MEZZANINE FLOOR
200 MM THICK RCC SLAB
200 MM THK SLAB DED 1.0 33.29 P-AREA 0.20 6.66 33.29
200 MM THK SLAB DED 1.0 13.10 P-AREA 0.20 2.62 13.10
200 MM THK SLAB DED 1.0 63.94 P-AREA 0.20 12.79 63.94
200 MM THK SLAB DED 1.0 13.05 P-AREA 0.20 2.61 13.05
150MM THICK RCC SLAB DED -1.0 16.24 P-AREA 0.20 -3.25 -16.24
Gorund Floor Level
Drg Title :- 20240916_MORKI_DD
FIRST FLOOR LEVEL
STAIRCASE -1.0 57.42 P-AREA 0.20 -11.48 -57.42
SECOND FLOOR LEVEL
STAIRCASE -1.0 34.30 P-AREA 0.20 -6.86 -34.30
THIRD FLOOR LEVEL
Drg Title : Staircase Detail
Between grid BDY2 TO BY1
Staircase from Lower Ground Level to Mezzanine floor
Landing 2.00 8.69 (area) 0.15 2.61
Staircase from Mezzanine floor to Ground floor
Landing 2.00 8.69 (area) 0.15 2.61
Staircase from Ground floor to First Floor
Landing 4.00 8.69 (area) 0.15 5.21
Staircase from First floor to Second Floor
Landing 5.00 8.69 (area) 0.15 6.52
SAME AS ABOVE 2.00 52.34 104.68
Staircase Shuttering
Drg Title : Staircase Detail
Drg Date. 25-09-2024
Between grid BDY2 TO BY1
Staircase from Lower Ground Level to Mezzanine floor
Landing 2.00 8.69 (area) 17.38
Staircase from Mezzanine floor to Ground floor
Landing 2.00 8.69 (area) 17.38
Staircase from Ground floor to First Floor
Landing 4.00 8.69 (area) 34.76
Staircase from First floor to Second Floor
Landing 5.00 8.69 (area) 43.45
SAME AS ABOVE 2.00 345.11 690.23
GROUND FLOOR LEVEL
FIRST FLOOR LEVEL
HORIZONATAL MEMBER
VERTICAL MEMBER
SECOND FLOOR LEVEL
HORIZONATAL MEMBER
VERTICAL MEMBER
VERTICAL MEMBER
THIRD FLOOR LEVEL
HORIZONATAL MEMBER
VERTICAL MEMBER
9.2 EXPANSION JOINT-EXTERIOR CODE-A12-13 & A11-03
2 ROOF TYPE - 1 (1-A11-03)
Drg Title : 2025-09-18_GVM_A12-08,09-EXT ROOF ,COPING LVL DIAGRAM
Drg No : A12-13
Drg Date : 19-09-2025
2 ROOF TYPE - 2 (2-A11-03)
Drg Title : 2025-09-18_GVM_A12-08,09-EXT ROOF ,COPING LVL DIAGRAM
Drg No : A12-13
Drg Date : 19-09-2025
Drg Title : 2025-09-18_GVM_A12-08,09-EXT ROOF ,COPING LVL DIAGRAM
Drg No : A12-13
Drg Date : 19-09-2025
3 ROOF TYPE - 3 (A11-03)
LOWER GROUD FLOOR
Drg Title : 2025-09-18_GVM_A12-08,09-EXT ROOF ,COPING LVL DIAGRAM
Drg No : A12-13
Drg Date : 19-09-2025
Drg Title : 2025-09-18_GVM_A12-08,09-EXT ROOF ,COPING LVL DIAGRAM
Drg No : A12-13
Drg Date : 19-09-2025
Drg Title : 2025-09-18_GVM_A12-08,09-EXT ROOF ,COPING LVL DIAGRAM
Drg No : A12-13
Drg Date : 19-09-2025
Drg Title : 2025-09-18_GVM_A12-08,09-EXT ROOF ,COPING LVL DIAGRAM
Drg No : A12-13
Drg Date : 19-09-2025
4 WALL TYPE - 1 (4-A11-03)
Drg Title : 2025-09-18_GVM_A12-08,09-EXT ROOF ,COPING LVL DIAGRAM
Drg No : A12-13
Drg Date : 19-09-2025
Drg Title : 2025-09-18_GVM_A12-08,09-EXT ROOF ,COPING LVL DIAGRAM
Drg No : A12-13
Drg Date : 19-09-2025
LOWER GROUD FLOOR
Drg Title : 2025-09-18_GVM_A12-08,09-EXT ROOF ,COPING LVL DIAGRAM
Drg No : A12-13
Drg Date : 19-09-2025
MEZZANINE FLOOR
Drg Title : 2025-09-18_GVM_A12-08,09-EXT ROOF ,COPING LVL DIAGRAM
Drg No : A12-13
Drg Date : 19-09-2025
Drg Title : 2025-09-18_GVM_A12-08,09-EXT ROOF ,COPING LVL DIAGRAM
Drg No : A12-13
Drg Date : 19-09-2025
Drg Title : 2025-09-18_GVM_A12-08,09-EXT ROOF ,COPING LVL DIAGRAM
Drg No : A12-13
Drg Date : 19-09-2025
Drg Title : 2025-09-18_GVM_A12-08,09-EXT ROOF ,COPING LVL DIAGRAM
Drg No : A12-13
Drg Date : 19-09-2025
9.2 EXPANSION JOINT-INTERIOR CODE-A12-13 & A11-03
1 WALL TYPE-3 (5-A14-11)
LOWER GROUD FLOOR
Drg Title : 2025-09-18_GVM_A12-08,09-EXT ROOF ,COPING LVL DIAGRAM
Drg No : A12-13
Drg Date : 19-09-2025
MEZZANINE FLOOR
Drg Title : 2025-09-18_GVM_A12-08,09-EXT ROOF ,COPING LVL DIAGRAM
Drg No : A12-13
Drg Date : 19-09-2025
Drg Title : 2025-09-18_GVM_A12-08,09-EXT ROOF ,COPING LVL DIAGRAM
Drg No : A12-13
Drg Date : 19-09-2025
Drg Title : 2025-09-18_GVM_A12-08,09-EXT ROOF ,COPING LVL DIAGRAM
Drg No : A12-13
Drg Date : 19-09-2025
2 FLOORING TYPE-1 (1-A14-11)
Drg Title : 2025-09-18_GVM_A12-08,09-EXT ROOF ,COPING LVL DIAGRAM
Drg No : A12-13
Drg Date : 19-09-2025
Drg Title : 2025-09-18_GVM_A12-08,09-EXT ROOF ,COPING LVL DIAGRAM
Drg No : A12-13
Drg Date : 19-09-2025
3 FLOORING TYPE-2 (2-A14-11)
Drg Title : 2025-09-18_GVM_A12-08,09-EXT ROOF ,COPING LVL DIAGRAM
Drg No : A12-13
Drg Date : 19-09-2025
Drg Title : 2025-09-18_GVM_A12-08,09-EXT ROOF ,COPING LVL DIAGRAM
Drg No : A12-13
Drg Date : 19-09-2025
4 FLOORING TYPE-3 (3-A14-11)
MEZZANINE FLOOR
Drg Title : 2025-09-18_GVM_A12-08,09-EXT ROOF ,COPING LVL DIAGRAM
Drg No : A12-13
Drg Date : 19-09-2025
Drg Title : 2025-09-18_GVM_A12-08,09-EXT ROOF ,COPING LVL DIAGRAM
Drg No : A12-13
Drg Date : 19-09-2025
Drg Title : 2025-09-18_GVM_A12-08,09-EXT ROOF ,COPING LVL DIAGRAM
Drg No : A12-13
Drg Date : 19-09-2025
Drg Title : 2025-09-18_GVM_A12-08,09-EXT ROOF ,COPING LVL DIAGRAM
Drg No : A12-13
Drg Date : 19-09-2025
5 FLOORING TYPE-3 (4-A14-11)
Drg Title : 2025-09-18_GVM_A12-08,09-EXT ROOF ,COPING LVL DIAGRAM
Drg No : A12-13
Drg Date : 19-09-2025
Drg Title : 2025-09-18_GVM_A12-08,09-EXT ROOF ,COPING LVL DIAGRAM
Drg No : A12-13
Drg Date : 19-09-2025
Drg Title : 2025-09-18_GVM_A12-08,09-EXT ROOF ,COPING LVL DIAGRAM
Drg No : A12-13
Drg Date : 19-09-2025
SuPr ENGINEERING & CONSULATANTS 307,SIDDHARTH UPSCALE VASANA ROAD VADODARA-390007 SUMMARY
VADODARA PROJECT : GUJARAT VANDANA MUSEUM, GUJARAT
DATE : 05-09-25 ARCHITECT : OPOLIS
PREPARED BY : d CLIENT : DIRECTORATE OF ARCHEOLOGY AND MUSEUMS, G.O.G
REV : CHECKED BY :
SR. NO. PARTICULAR UNIT Qty. Floor NO. Total QTY. WITH CONTIGENCY
1.1.11 EXCAVATION FOR PILE 600MM DIA RMT 8480.00 1.00 8480.00 8904.00
1.3 ANTITERMITE TREATMENT
RAFT SLAB LEVELFLOOR Sqm 2274.20 1.00 2274.20
GROUND FLOOR LEVEL Sqm 1033.69 1.00 1033.69
Total Sqm 3307.89 3639.00
Footing level Cum 150.10 1.00 150.10
PCC BELOW RETAINING WALL Cum 33.51 1.00 33.51
BELOW RAFT SLAB PCC Cum 441.99 1.00 441.99
Total Cum 625.61 657.00
450MM THICK GRADE SLAB
Lower Ground Level Cum 552.62 1.00 552.62
Total Cum 552.62 581.00
1.8 150MM THICK RAFT SLAB
Ground Level Cum 1.89 1.00 1.89
Total Cum 1.89 2.00
FOOTING LEVEL Cum 781.39 1.00 781.39
Total Cum 781.39 821.00
2 STRUCTURAL WORK
2.1 CONCRETE WORK
@ Pile Concrete (M40)
Total Cum 2396.45 2517.00
@ Footing Pile Cap
Total Cum 1223.67 1285.00
@ CHIPING BREAKING PILE HEAD Cum 44.93 1.00 44.93
Total Cum 44.93 48.00
@ Raft Slab BELOW Retaining Wall (M40) Cum 502.06 1.00 502.06
Total Cum 502.06 528.00
UP TO GRADE SLAB Cum 41.27 1.00 41.27
RAFT SLAB LEVEL(LOWER GROUND FLOOR) Cum 131.67 1.00 131.67
MEZZANINE FLOOR Cum 59.72 1.00 59.72
GROUND FLOOR Cum 206.47 1.00 206.47
FIRST FLOOR Cum 265.80 1.00 265.80
SECOND FLOOR Cum 246.73 1.00 246.73
Connecting Bridge Level Plan Cum 496.62 1.00 496.62
Total Cum 1448.27 1521.00
@ RETAINING WALL
GRADE OF CONCRETE M40
UP TO GRADE SLAB Cum 81.12 1.00 81.12
RAFT SLAB LEVEL Cum 258.81 1.00 258.81
MEZZANINE LEVEL Cum 182.03 1.00 182.03
GROUND FLOOR LEVEL Cum 2.96 1.00 2.96
Total Cum 524.93 552.00
@ SHEAR WALL (M40)
UP TP GRADE SLAB Cum 15.80 1.00 15.80
RAFT SLAB LEVEL Cum 50.40 1.00 50.40
MEZZANINE FLOOR LVL Cum 9.77 1.00 9.77
GROUND FLOOR LVL Cum 92.52 1.00 92.52
FIRST FLOOR LVL Cum 111.33 1.00 111.33
SECOND FLOOR LVL Cum 98.81 1.00 98.81
Total Cum 378.63 398.00
@ FLOOR BEAM (M40)
RAFT SLAB LEVEL Cum 50.52 1.00 50.52
Total Cum 50.52 54.00
MEZZANINE LVL FLOOR Cum 15.81 1.00 15.81
GROUND FLOOR Cum 137.00 1.00 137.00
FIRST FLOOR Cum 148.67 1.00 148.67
SECOND FLOOR Cum 137.38 1.00 137.38
Total Cum 438.86 461.00
@ 250 MM THICK RCC SLAB (M40)
MEZZANINE FLOOR Cum 177.57 1.00 177.57
Gorund Floor Level Cum 152.00 1.00 152.00
Total Cum 329.57 347.00
@ 150 MM THICK RCC SLAB
MEZZANINE FLOOR Cum 10.77 1.00 10.77
Ground FLOOR Cum 44.83 1.00 44.83
FIRST FLOOR Cum 69.68 1.00 69.68
SECOND FLOOR Cum 49.68 1.00 49.68
Total Cum 174.96 184.00
@ 200 MM THICK RCC SLAB
Ground FLOOR Cum 49.48 1.00 49.48
SECOND FLOOR Cum 13.75 1.00 13.75
Total Cum 63.23 67.00
Gorund Floor Level Cum 137.85 1.00 137.85
FIRST FLOOR LEVEL Cum 267.92 1.00 267.92
SECOND FLOOR LEVEL Cum 282.64 1.00 282.64
Connecting Bridge Level Plan Cum 35.54 1.00 35.54
Total Cum 723.96 761.00
Gorund Floor Level Sqm 689.27 1.00 689.27
FIRST FLOOR LEVEL Sqm 1380.87 1.00 1380.87
SECOND FLOOR LEVEL Sqm 1413.22 1.00 1413.22
Connecting Bridge Level Plan Sqm 177.69 1.00 177.69
Total Sqm 3661.05 3845.00
BASEMENT TO FOURTH FLOOR Cum 86.28 1.00 86.28
Total Cum 86.28 91.00
Total OF M40 GRADE Cum 6544.37 6872.00
@ STEEL BEAM (STRUCTURAL STEEL) 7.1B
PILE FOUNDATION FOR CONNECTING BRIDGE LEVEL kg 34,854.31 1.00 34,854.31
GROUND FLOOR LEVEL kg 1.00 0.00
FIRST FLOOR LEVEL kg 1.00 0.00
SECOND FLOOR LEVEL kg 1.00 0.00
Total MT 34.85 37.00
@ STEEL BEAM PAINT
PILE FOUNDATION FOR CONNECTING BRIDGE LEVEL Sqm 1,151.73 1.00 1,151.73
GROUND FLOOR LEVEL Sqm 0.00 1.00 0.00
FIRST FLOOR LEVEL Sqm 0.00 1.00 0.00
SECOND FLOOR LEVEL Sqm 0.00 1.00 0.00
PILE FOUNDATION FOR CONNECTING BRIDGE LEVEL kg 22,125.11 1.00 22,125.11
GROUND FLOOR LEVEL kg 215,862.64 1.00 215,862.64
FIRST FLOOR LEVEL kg 246,184.53 1.00 246,184.53
SECOND FLOOR LEVEL kg 271,758.03 1.00 271,758.03
Total MT 755.93 794.00
@ STEEL BEAM PAINT
PILE FOUNDATION FOR CONNECTING BRIDGE LEVEL Sqm 421.30 1.00 421.30
GROUND FLOOR LEVEL Sqm 2,445.07 1.00 2,445.07
FIRST FLOOR LEVEL Sqm 1,868.22 1.00 1,868.22
SECOND FLOOR LEVEL Sqm 1,796.95 1.00 1,796.95
PILE FOUNDATION FOR CONNECTING BRIDGE LEVEL kg 24465.43 1.00 24,465.43
BASE PLATE & TRUSS & TIE BEAM LEVEL PLAN kg 30629.01 1.00 30,629.01
TRUSS LINE DIAGRAM kg 1,776.73 1.00 1,776.73
Total MT 56.87 60.00
@ STEEL COLUMN PAINT
PILE FOUNDATION FOR CONNECTING BRIDGE LEVEL kg 216.83 1.00 216.83
BASE PLATE & TRUSS & TIE BEAM LEVEL PLAN kg 135.06 1.00 135.06
TRUSS LINE DIAGRAM kg 46.64 1.00 46.64
Total kg 398.52 419.00
TRUSS & TIE BEAM LAYOUT Cum 1406.64 1.00 1406.64
TRUSS LINE DIAGRAM Cum 89.67 1.00 89.67
PILE FOUNDATION FOR CONNECTING BRIDGE LEVEL Cum 193.18 1.00 193.18
Total Cum 1689.49 1774.00
@ GLASS CLADDING
TRUSS LINE DIAGRAM Sqm 237.04 1.00 237.04
Total Sqm 237.04 249.00
@ 25 MM THICK BASE PLATE
25 MM THICK BASE PLATE Sqm 11.54 1.00 11.54
Total Sqm 11.54 13.00
@ 42MM DIA BOLT
TRUSS & TIE BEAM LAYOUT NOS 160.00 1.00 160.00
Total NOS 160.00 168.00
TRUSS & TIE BEAM LAYOUT NOS 30.00 1.00 30.00
Total NOS 30.00 32.00
@ Footing Pile Cap
Total Sqm 1626.42 1790.00
@ Raft Slab BELOW Retaining Wall (M40)
Total Sqm 485.98 535.00
UP TO GRADE SLAB Sqm 229.80 1.00 229.80
RAFT SLAB LEVEL(LOWER GROUND FLOOR) Sqm 733.18 1.00 733.18
MEZZANINE FLOOR Sqm 357.18 1.00 357.18
GROUND FLOOR Sqm 1181.97 1.00 1181.97
FIRST FLOOR Sqm 1443.10 1.00 1443.10
SECOND FLOOR Sqm 1226.37 1.00 1226.37
Connecting Bridge Level Plan Sqm 126.18 1.00 126.18
Total Sqm 5297.77 5828.00
@ RETAINING WALL
UP TO GRADE SLAB Sqm 540.79 1.00 540.79
RAFT SLAB LEVEL Sqm 1725.39 1.00 1725.39
MEZZANINE LEVEL Sqm 1213.57 1.00 1213.57
GROUND FLOOR LEVEL Sqm 19.77 1.00 19.77
Total Sqm 3499.52 3850.00
UP TO GRADE SLAB Sqm 100.65 1.00 100.65
RAFT SLAB LEVEL Sqm 321.13 1.00 321.13
MEZZANINE FLOOR LVL Sqm 65.15 1.00 65.15
GROUND FLOOR LVL Sqm 589.54 1.00 589.54
FIRST FLOOR LVL Sqm 709.36 1.00 709.36
SECOND FLOOR LVL Sqm 625.96 1.00 625.96
Total Sqm 2411.79 2653.00
RAFT SLAB LEVEL Sqm 335.78 1.00 335.78
Total Sqm 335.78 370.00
MEZZANINE LVL FLOOR Sqm 143.74 1.00 143.74
GROUND FLOOR Sqm 877.53 1.00 877.53
FIRST FLOOR Sqm 881.70 1.00 881.70
SECOND FLOOR Sqm 788.29 1.00 788.29
Total Sqm 2691.26 2961.00
@ 250 MM THICK RCC SLAB (M40)
MEZZANINE FLOOR Sqm 710.26 1.00 710.26
Gorund Floor Level Sqm 608.01 1.00 608.01
Total Sqm 1318.27 1451.00
@ 150 MM THICK RCC SLAB
MEZZANINE FLOOR Sqm 71.83 1.00 71.83
Ground FLOOR Sqm 298.86 1.00 298.86
FIRST FLOOR Sqm 464.55 1.00 464.55
SECOND FLOOR Sqm 331.17 1.00 331.17
Total Sqm 1166.41 1284.00
@ 200 MM THICK RCC SLAB
Ground FLOOR Sqm 247.41 1.00 247.41
SECOND FLOOR Sqm 68.74 1.00 68.74
Total Sqm 316.15 348.00
Gorund Floor Level Sqm 137.85 1.00 137.85
FIRST FLOOR LEVEL Sqm 267.92 1.00 267.92
SECOND FLOOR LEVEL Sqm 282.64 1.00 282.64
Total Sqm 688.42 758.00
BASEMENT TO FOURTH FLOOR Sqm 568.95 1.00 568.95
Total Sqm 568.95 626.00
3 REINFORCEMENT KG/CUM
RETAINING WALL 100.00 524.93 52492.7295
SALB BEAM & MAIN BEAM 300.00 438.86 131657.4504
EXPANSION JOINT-EXTERIOR CODE-A12-13 & A11-03
1 ROOF TYPE - 1 (1-A11-03)
Basement Floor Rmt 0.00 1.00 0.00
Lower Ground Floor Rmt 0.00 1.00 0.00
Mezzanine Floor Rmt 0.00 1.00 0.00
Ground Floor Rmt 0.00 1.00 0.00
First Floor Rmt 0.00 1.00 0.00
Second Floor Rmt 0.00 1.00 0.00
Third Floor Rmt 0.00 1.00 0.00
Fourth Floor Rmt 5.78 1.00 5.78
Total Rmt 5.78 7.00
2 ROOF TYPE - 2 (2-A11-03)
Basement Floor Rmt 0.00 1.00 0.00
Lower Ground Floor Rmt 0.00 1.00 0.00
Mezzanine Floor Rmt 0.00 1.00 0.00
Ground Floor Rmt 0.00 1.00 0.00
First Floor Rmt 3.70 1.00 3.70
Second Floor Rmt 0.00 1.00 0.00
Third Floor Rmt 0.00 1.00 0.00
Fourth Floor Rmt 12.12 1.00 12.12
Total Rmt 15.82 18.00
3 ROOF TYPE - 3 (A11-03)
Basement Floor Rmt 0.00 1.00 0.00
Lower Ground Floor Rmt 0.00 1.00 0.00
Mezzanine Floor Rmt 0.00 1.00 0.00
Ground Floor Rmt 34.10 1.00 34.10
First Floor Rmt 0.00 1.00 0.00
Second Floor Rmt 0.00 1.00 0.00
Third Floor Rmt 0.00 1.00 0.00
Fourth Floor Rmt 0.72 1.00 0.72
Total Rmt 34.82 39.00
4 WALL TYPE - 1 (4-A11-03)
Basement Floor Rmt 0.00 1.00 0.00
Lower Ground Floor Rmt 0.00 1.00 0.00
Mezzanine Floor Rmt 0.00 1.00 0.00
Ground Floor Rmt 21.60 1.00 21.60
First Floor Rmt 7.20 1.00 7.20
Second Floor Rmt 0.00 1.00 0.00
Third Floor Rmt 0.00 1.00 0.00
Fourth Floor Rmt 0.00 1.00 0.00
Total Rmt 28.80 32.00
Basement Floor Rmt 0.00 1.00 0.00
Lower Ground Floor Rmt 7.20 1.00 7.20
Mezzanine Floor Rmt 0.00 1.00 0.00
Ground Floor Rmt 7.20 1.00 7.20
First Floor Rmt 7.20 1.00 7.20
Second Floor Rmt 0.00 1.00 0.00
Third Floor Rmt 0.00 1.00 0.00
Fourth Floor Rmt 0.00 1.00 0.00
Total Rmt 21.60 24.00
9.2 EXPANSION JOINT-INTERIOR CODE-A12-13 & A11-03
1 WALL TYPE-3 (5-A14-11)
Basement Floor Rmt 0.00 1.00 0.00
Lower Ground Floor Rmt 86.40 1.00 86.40
Mezzanine Floor Rmt 0.00 1.00 0.00
Ground Floor Rmt 28.80 1.00 28.80
First Floor Rmt 43.20 1.00 43.20
Second Floor Rmt 0.00 1.00 0.00
Third Floor Rmt 0.00 1.00 0.00
Fourth Floor Rmt 0.00 1.00 0.00
Total Rmt 158.40 175.00
2 FLOORING TYPE-1 (1-A14-11)
Basement Floor Rmt 0.00 1.00 0.00
Lower Ground Floor Rmt 0.00 1.00 0.00
Mezzanine Floor Rmt 0.00 1.00 0.00
Ground Floor Rmt 5.35 1.00 5.35
First Floor Rmt 3.55 1.00 3.55
Second Floor Rmt 0.00 1.00 0.00
Third Floor Rmt 0.00 1.00 0.00
Fourth Floor Rmt 0.00 1.00 0.00
Total Rmt 8.90 10.00
3 FLOORING TYPE-2 (2-A14-11)
Basement Floor Rmt 0.00 1.00 0.00
Lower Ground Floor Rmt 0.00 1.00 0.00
Mezzanine Floor Rmt 0.00 1.00 0.00
Ground Floor Rmt 11.75 1.00 11.75
First Floor Rmt 0.00 1.00 0.00
Second Floor Rmt 0.00 1.00 0.00
Third Floor Rmt 0.00 1.00 0.00
Fourth Floor Rmt 0.00 1.00 0.00
Total Rmt 11.75 13.00
4 FLOORING TYPE-3 (3-A14-11)
Basement Floor Rmt 0.00 1.00 0.00
Lower Ground Floor Rmt 0.00 1.00 0.00
Mezzanine Floor Rmt 0.00 1.00 0.00
Ground Floor Rmt 3.31 1.00 3.31
First Floor Rmt 9.34 1.00 9.34
Second Floor Rmt 0.00 1.00 0.00
Third Floor Rmt 0.00 1.00 0.00
Fourth Floor Rmt 0.00 1.00 0.00
Total Rmt 12.65 14.00
5 FLOORING TYPE-4 (4-A14-11)
Basement Floor Rmt 0.00 1.00 0.00
Lower Ground Floor Rmt 0.00 1.00 0.00
Mezzanine Floor Rmt 0.00 1.00 0.00
Ground Floor Rmt 7.49 1.00 7.49
First Floor Rmt 2.97 1.00 2.97
Second Floor Rmt 0.00 1.00 0.00
Third Floor Rmt 0.00 1.00 0.00
Fourth Floor Rmt 0.00 1.00 0.00
Total Rmt 10.45 12.00
SuPr ENGINEERING & CONSULATANT 307,SIDDHARTH UPSCALE VASANA ROAD VADODARA-390007 MEASUREMENT
VADODARA ARCHITECT:-
DATE : 24.09.2024 CLIENT:-
PREPARED BY : CHECKED BY :
SR.NO. PARTICULARS NO. L B D / H QTY.
Drg No :- Depht- 1.50 mt
Mass excavation for lower Ground floor level
BLOCK E 1.0 0.00 P-area 1.50 0.00
BLOCK F 1.0 865.16 P-area 1.50 1297.74 Block F N.G.L = 61.13 FLOOR EXCAVATION = 0 PILE EXCAVATION = 2.03 TOTAL EXCAVATION = 2.03
BLOCK G 1.0 1806.25 P-area 1.50 2709.38 Block G N.G.L = 58.85 FLOOR EXCAVATION = -4.25 PILE EXCAVATION = -2.7 TOTAL EXCAVATION = -6.95
BLOCK G BRIDGE (K37) 1.0 57.96 P-area 1.50 86.94 Block G BRIDGE N.G.L = 53.50 FLOOR EXCAVATION = -0.07 PILE EXCAVATION = -2.7 TOTAL EXCAVATION = -2.77
BLOCK G BRIDGE (K38 & K39) & FLOOR 1.0 29.33 5.60 1.50 246.36 Block G BRIDGE N.G.L = 58.25 FLOOR EXCAVATION = -4.82 PILE EXCAVATION = -2.7 TOTAL EXCAVATION = -7.52
Drg No :- Depht- 1.50 mt
Mass excavation for lower Ground floor level
BLOCK E 1.0 0.00 P-area 1.00 0.00
BLOCK G BRIDGE (K37) 1.0 57.96 P-area 1.20 69.55
BLOCK G BRIDGE (K38 & K39) & FLOOR 1.0 29.33 5.60 1.50 246.36
Drg No :- Depht- 1.50 mt
Mass excavation for lower Ground floor level
BLOCK G BRIDGE (K38 & K39) & FLOOR 1.0 29.33 5.60 0.65 106.76
Drg No :- Depht- 1.50 mt
Mass excavation for lower Ground floor level
Drg No :- Depht- 1.50 mt
Mass excavation for lower Ground floor level
1.1.11 EXCAVATION FOR PILE 600MM DIA
Drg No :- Depht- 16.00 mt
Connecting Bridge Pile Foundation
1.2 BACK FILLING
Drg Title :- NA
Total excavation for block F 1.0 1756.27 Qty 1756.27
Ded of pile cap -1.0 247.59 -247.59
Ded of columns -1.0 13.78 -13.78
Ded of r.wall -1.0 37.85 -37.85
Ded of retaining wall raft slab -1.0 199.60 -199.60
Ded of grade slab -1.0 187.74 -187.74
Ded of shear wall -1.0 2.03 -2.03
Total excavation for block G 1.0 12553.44 Qty 12553.44
Ded of pile cap -1.0 766.14 -766.14
Ded of columns -1.0 27.49 -27.49
Ded of r.wall -1.0 43.27 -43.27
Ded of retaining wall raft slab -1.0 302.46 -302.46
Ded of grade slab -1.0 345.00 -345.00
Ded of shear wall -1.0 13.76 -13.76
Total excavation for block G BRIDGE 1.0 1021.38 Qty 1021.38
Ded of pile cap -1.0 97.61 -97.61
Ded of columns -1.0 0.00 0.00
Ded of r.wall -1.0 0.00 0.00
Ded of retaining wall raft slab -1.0 0.00 0.00
Ded of grade slab -1.0 0.00 0.00
Ded of gsb -1.0 0.00 0.00
deduction for pile cap from slab -1.0 750.70 P-area 0.25 -187.68
1.2 SOIL FILLING
Drg Title :- NA
Drg Date:- NA 58.9
Ded of pile cap -1.0 112.32 -112.32
Ded of columns -1.0 0.00 0.00
Ded of grade slab -1.0 207.56 -207.56
1.3 ANTITERMITE TREATMENT
RAFT SLAB LEVELFLOOR
Drg Title : RAFT SLAB LEVELFLOOR
BLOCK F 1.0 819.46 P-area 819.46
BLOCK G 1.0 1454.74 P-area 1454.74
GROUND FLOOR LEVEL
Drg Title : GROUND FLOOR LEVEL
BLOCK E 1.0 1033.69 P-area 1033.69
@ FOOTING LEVEL
Drg Title :- NA
Drg No :- BGA/GVM/STR-101
Connecting Bridge Pile Foundation 94.03
@ PCC BELOW GRADE SLAB
@ FOOTING LEVEL
Drg No :- BGA/GVM/STR-101
@ PCC BELOW RETAINING WALL
@ FOOTING LEVEL
Drg No :- BGA/GVM/STR-101
Lower Ground Level
Drg Title :- NA
Drg No :- BGA/GVM/STR-101
BLOCK F 1.0 44.82 P-area 0.25 11.21
BLOCK F 1.0 31.52 P-area 0.25 7.88
BLOCK G 1.0 31.71 P-area 0.25 7.93
deduction for pile cap -1.0 750.70 P-area 0.25 -187.68
Drg Title :- NA
Drg No :- BGA/GVM/STR-101
BLOCK F 1.0 12.63 P-area 0.15 1.89
@ FOOTING LEVEL
Drg Title :- NA
2.1 CONCRETE WORK
@ Footing Pile Cap
Connecting Bridge Pile Foundation
@ Pile Concrete (M40)
Connecting Bridge Pile Foundation
CHIPING BREAKING PILE HEAD
@ Raft Slab BELOW Retaining Wall (M40)
UP TO RAFT SLAB LVL
Drg No :- HT 0.60
Drg No :- NA SLB THK 0.00
Drg Date:- 0.60
@ RCC COLUMN (M40)
RAFT SLAB LEVEL(LOWER GROUND FLOOR)
Drg No :- HT 3.60
Drg No :- NA SLB THK -0.25
Drg Date:- 3.35
MEZZANINE FLOOR
Drg No :- HT 4.80
Drg No :- NA SLB THK -0.25
Drg Date:- 4.55
Drg No :- HT 6.00
Drg No :- NA SLB THK -0.25
Drg Date:- 5.75
Drg No :- HT 7.20
Drg No :- NA SLB THK -0.20
Drg Date:- 7.00
Drg No :- NA HT 4.95
Drg Date:- SLB THK -0.20
Connecting Bridge Level Plan
Drg No :- NA HT
Drg Date:- SLB THK
@ RETAINING WALL
GRADE OF CONCRETE M40
RAFT SLAB LEVEL
@ RETAINING WALL
GRADE OF CONCRETE M40
RAFT SLAB LEVEL
@ RETAINING WALL
GRADE OF CONCRETE M40
MEZZANINE LEVEL
@ RETAINING WALL
GRADE OF CONCRETE M40
GROUND FLOOR LEVEL
GRADE OF CONCRETE M40
RAFT SLAB LEVEL
GRADE OF CONCRETE M40
RAFT SLAB LEVEL
GRADE OF CONCRETE M40
MEZZANINE FLOOR LVL HT 4.80
Drg Title :- SLAB -0.25
Drg No :- NA 5.05
GROUND FLOOR LVL HT 6.00
Drg Title :- SLAB -0.15
Drg No :- NA 6.15
FIRST FLOOR LVL HT 7.20
Drg Title :- SLAB -0.20
Drg No :- NA 7.40
SECOND FLOOR LVL
@ RCC FLOOR BEAM
GRADE OF CONCRETE M40
RAFT SLAB LEVEL
MEZZANINE LVL FLOOR
Beam Depth 0.60 Beam Depth 0.80
Slab Thk. -0.20 Slab Thk. -0.20
Beam Depth 0.50 Beam Depth 0.60
Slab Thk. -0.15 Slab Thk. -0.23
Beam Depth 0.60 Beam Depth 0.60
Slab Thk. -0.25 Slab Thk. -0.15
Beam Depth 0.60 Beam Depth 0.90
Slab Thk. -0.25 Slab Thk.
Beam Depth 0.60 Beam Depth 1.00
Slab Thk. -0.20 Slab Thk.
Beam Depth 0.60 Beam Depth 0.75
Slab Thk. -0.23 Slab Thk.
Beam Depth 0.60 Beam Depth 0.80
Slab Thk. -0.15 Slab Thk.
Beam Depth 0.75 Beam Depth 0.50
Slab Thk. -0.25 Slab Thk. -0.15
Beam Depth 0.60 Beam Depth 0.75
Slab Thk. -0.15 Slab Thk. -0.15
Beam Depth 1.00
Slab Thk. -0.15
Beam Depth 0.60 Beam Depth 0.75
Slab Thk. -0.15 Slab Thk. -0.15
Beam Depth 1.00
Slab Thk. -0.15
@ 250 MM THICK RCC SLAB (M40)
MEZZANINE FLOOR
Drg Title :- 20240916_MORKI_DD
150 MM THK SLAB DED -1.0 16.83 P-AREA 0.25 -4.21 -16.83
STAIRCASE -1.0 37.37 P-AREA 0.25 -9.34 -37.37
Gorund Floor Level
Drg Title :- 20240916_MORKI_DD
150 MM THICK SLAB -1.0 30.59 P-AREA 0.25 -7.65 -30.59
150 MM THICK SLAB -1.0 16.51 P-AREA 0.25 -4.13 -16.51
STAIRCASE -1.0 39.89 P-AREA 0.25 -9.97 -39.89
150 MM THICK RCC SLAB
MEZZANINE FLOOR
150 MM THK SLAB DED 1.0 16.83 P-AREA 0.15 2.52 16.83
150 MM THICK RCC SLAB
150 MM THICK SLAB 1.0 30.59 P-AREA 0.15 4.59 30.59
150 MM THICK SLAB 1.0 16.51 P-AREA 0.15 2.48 16.51
150 MM THICK SLAB 1.0 52.50 P-AREA 0.15 7.88 52.50
150 MM THICK SLAB 1.0 69.56 P-AREA 0.15 10.43 69.56
150 MM THICK SLAB 1.0 50.51 P-AREA 0.15 7.58 50.51
150 MM THICK SLAB 1.0 31.99 P-AREA 0.15 4.80 31.99
150 MM THICK SLAB 1.0 12.10 P-AREA 0.15 1.82 12.10
150 MM THICK RCC SLAB
150 MM THICK SLAB 1.0 50.22 P-AREA 0.15 7.53 50.22
150 MM THICK SLAB 1.0 115.38 P-AREA 0.15 17.31 115.38
150 MM THICK SLAB 1.0 30.50 P-AREA 0.15 4.58 30.50
150 MM THICK SLAB 1.0 65.88 P-AREA 0.15 9.88 65.88
150 MM THICK SLAB 1.0 39.57 P-AREA 0.15 5.94 39.57
150 MM THICK RCC SLAB
150 MM THK SLAB 1.0 9.85 P-AREA 0.15 1.48 9.85
200 MM THICK RCC SLAB
Gorund Floor Level
Drg Title :- 20240916_MORKI_DD
FIRST FLOOR LEVEL
STAIRCASE -1.0 29.44 P-AREA 0.20 -5.89 -29.44
DECK SLAB 1.0 82.55 P-AREA 0.10 8.26 82.55
SECOND FLOOR LEVEL
STAIRCASE -1.0 29.44 P-AREA 0.20 -5.89 -29.44
Connecting Bridge Level Plan
Drg Title : Staircase Detail
Between grid BDY2 TO BY1
Staircase from Lower Ground Level to Mezzanine floor
Landing 2.00 8.69 (area) 0.15 2.61
Staircase from Mezzanine floor to Ground floor
Landing 2.00 8.69 (area) 0.15 2.61
Staircase from Ground floor to First Floor
Landing 4.00 8.69 (area) 0.15 5.21
Staircase from First floor to Second Floor
Landing 5.00 8.69 (area) 0.15 6.52
SAME AS OTHER 1 1.00 33.94 33.94
Staircase Shuttering
Drg Title : Staircase Detail
Drg Date. 25-09-2024
Between grid BDY2 TO BY1
Staircase from Lower Ground Level to Mezzanine floor
Landing 2.00 8.69 (area) 17.38
Staircase from Mezzanine floor to Ground floor
Landing 2.00 8.69 (area) 17.38
Staircase from Ground floor to First Floor
Landing 4.00 8.69 (area) 34.76
Staircase from First floor to Second Floor
Landing 5.00 8.69 (area) 43.45
SAME AS OTHER 1 1.00 223.84 223.84
PILE FOUNDATION FOR CONNECTING BRIDGE LEVEL
Drg No :- BGA/-/STR-00
PILE FOUNDATION FOR CONNECTING BRIDGE LEVEL
Drg No :- BGA/-/STR-00
ELEVATION ALONG GRID A & B
TIE BEAM LAYOUT
ROOF TIE BEAM LAYOUT
GROUND FLOOR LEVEL
SAME AS 3 (TRUSS 1) - PAINT 3 79.08 237.240 237.240
PURLIN 0.00 0.000
FIRST FLOOR LEVEL
HORIZONATAL MEMBER
BEAM AND BRACING LAYOUT 0.000
RAFTER AND PURLIN LAYOUT
ELEVATION ALONG GRID A & B 0.000
SECOND FLOOR LEVEL
PILE FOUNDATION FOR CONNECTING BRIDGE LEVEL
BASE PLATE & TRUSS & TIE BEAM LEVEL PLAN
TRUSS & TIE BEAM LAYOUT
TRUSS LINE DIAGRAM
TRUSS & TIE BEAM LAYOUT
ROOF SHEET 1.0 1406.64 P-AREA 1406.64
TRUSS LINE DIAGRAM
ROOF SHEET 1.0 89.67 P-AREA 89.67
PILE FOUNDATION FOR CONNECTING BRIDGE LEVEL
Drg No :- BGA/-/STR-00
ROOF SHEETING LAYOUT 1.00 193.18 P-AREA 193.18
TRUSS LINE DIAGRAM
25 MM THICK BASE PLATE
TRUSS & TIE BEAM LAYOUT
TRUSS & TIE BEAM LAYOUT
TRUSS & TIE BEAM LAYOUT
9.2 EXPANSION JOINT-EXTERIOR CODE-A12-13 & A11-03
2 ROOF TYPE - 1 (1-A11-03)
Drg Title : 2025-09-18_GVM_A12-08,09-EXT ROOF ,COPING LVL DIAGRAM
Drg No : A12-13
Drg Date : 19-09-2025
2 ROOF TYPE - 2 (2-A11-03)
Drg Title : 2025-09-18_GVM_A12-08,09-EXT ROOF ,COPING LVL DIAGRAM
Drg No : A12-13
Drg Date : 19-09-2025
Drg Title : 2025-09-18_GVM_A12-08,09-EXT ROOF ,COPING LVL DIAGRAM
Drg No : A12-13
Drg Date : 19-09-2025
3 ROOF TYPE - 3 (A11-03)
Drg Title : 2025-09-18_GVM_A12-08,09-EXT ROOF ,COPING LVL DIAGRAM
Drg No : A12-13
Drg Date : 19-09-2025
Drg Title : 2025-09-18_GVM_A12-08,09-EXT ROOF ,COPING LVL DIAGRAM
Drg No : A12-13
Drg Date : 19-09-2025
4 WALL TYPE - 1 (4-A11-03)
Drg Title : 2025-09-18_GVM_A12-08,09-EXT ROOF ,COPING LVL DIAGRAM
Drg No : A12-13
Drg Date : 19-09-2025
Drg Title : 2025-09-18_GVM_A12-08,09-EXT ROOF ,COPING LVL DIAGRAM
Drg No : A12-13
Drg Date : 19-09-2025
LOWER GROUD FLOOR
Drg Title : 2025-09-18_GVM_A12-08,09-EXT ROOF ,COPING LVL DIAGRAM
Drg No : A12-13
Drg Date : 19-09-2025
Drg Title : 2025-09-18_GVM_A12-08,09-EXT ROOF ,COPING LVL DIAGRAM
Drg No : A12-13
Drg Date : 19-09-2025
Drg Title : 2025-09-18_GVM_A12-08,09-EXT ROOF ,COPING LVL DIAGRAM
Drg No : A12-13
Drg Date : 19-09-2025
9.2 EXPANSION JOINT-INTERIOR CODE-A12-13 & A11-03
LOWER GROUD FLOOR
Drg Title : 2025-09-18_GVM_A12-08,09-EXT ROOF ,COPING LVL DIAGRAM
Drg No : A12-13
Drg Date : 19-09-2025
Drg Title : 2025-09-18_GVM_A12-08,09-EXT ROOF ,COPING LVL DIAGRAM
Drg No : A12-13
Drg Date : 19-09-2025
Drg Title : 2025-09-18_GVM_A12-08,09-EXT ROOF ,COPING LVL DIAGRAM
Drg No : A12-13
Drg Date : 19-09-2025
2 FLOORING TYPE-1 (1-A14-11)
Drg Title : 2025-09-18_GVM_A12-08,09-EXT ROOF ,COPING LVL DIAGRAM
Drg No : A12-13
Drg Date : 19-09-2025
Drg Title : 2025-09-18_GVM_A12-08,09-EXT ROOF ,COPING LVL DIAGRAM
Drg No : A12-13
Drg Date : 19-09-2025
3 FLOORING TYPE-2 (2-A14-11)
Drg Title : 2025-09-18_GVM_A12-08,09-EXT ROOF ,COPING LVL DIAGRAM
Drg No : A12-13
Drg Date : 19-09-2025
4 FLOORING TYPE-3 (3-A14-11)
Drg Title : 2025-09-18_GVM_A12-08,09-EXT ROOF ,COPING LVL DIAGRAM
Drg No : A12-13
Drg Date : 19-09-2025
Drg Title : 2025-09-18_GVM_A12-08,09-EXT ROOF ,COPING LVL DIAGRAM
Drg No : A12-13
Drg Date : 19-09-2025
5 FLOORING TYPE-4 (4-A14-11)
Drg Title : 2025-09-18_GVM_A12-08,09-EXT ROOF ,COPING LVL DIAGRAM
Drg No : A12-13
Drg Date : 19-09-2025
Drg Title : 2025-09-18_GVM_A12-08,09-EXT ROOF ,COPING LVL DIAGRAM
Drg No : A12-13
Drg Date : 19-09-2025
SuPr ENGINEERING & CONSULATANTS 307,SIDDHARTH UPSCALE VASANA ROAD VADODARA-390007 SUMMARY
VADODARA PROJECT : GUJARAT VANDANA MUSEUM, GUJARAT
DATE : 05-09-25 ARCHITECT : OPOLIS
PREPARED BY : d CLIENT : DIRECTORATE OF ARCHEOLOGY AND MUSEUMS, G.O.G
REV : CHECKED BY :
SR. NO. PARTICULAR UNIT Qty. Floor NO. Total QTY. WITH CONTIGENCY
1.1.11 EXCAVATION FOR PILE 600MM DIA RMT 12384.00 1.00 12384.00 13004.00
1.3 ANTITERMITE TREATMENT
RAFT SLAB LEVELFLOOR Sqm 2633.75 1.00 2633.75
Total Sqm 2633.75 2898.00
Footing level Cum 211.28 1.00 211.28
BELOW RAFT SLAB PCC Cum 300.31 1.00 300.31
Total Cum 511.59 538.00
450 MM THICK RAFT SLAB
Lower Ground Level Cum 367.55 1.00 367.55
Total Cum 367.55 386.00
FOOTING LEVEL Cum 658.44 1.00 658.44
Total Cum 658.44 692.00
2 STRUCTURAL WORK
2.1 CONCRETE WORK
@ Pile Concrete (M40)
Total Cum 3499.72 3675.00
@ Footing Pile Cap
Total Cum 1856.94 1950.00
@ CHIPING BREAKING PILE HEAD Cum 65.62 1.00 65.62
Total Cum 65.62 69.00
UP TO GRADE SLAB Cum 59.54 1.00 59.54
BASMENT FLOOR Cum 277.83 1.00 277.83
RAFT SLAB LEVEL(LOWER GROUND FLOOR) Cum 379.89 1.00 379.89
GROUND FLOOR Cum 379.89 1.00 379.89
FIRST FLOOR Cum 379.89 1.00 379.89
SECOND FLOOR Cum 277.83 1.00 277.83
THIRD FLOOR Cum 277.83 1.00 277.83
FOURTH FLOOR Cum 283.50 1.00 283.50
Total Cum 2316.20 2433.00
WATER TANK WALL
@ 300MM THICK NON STRUCTURALWALL
FOUNDATION LEVEL Cum 113.87 1.00 113.87
RAFT SLAB LEVEL Cum 161.58 1.00 161.58
Total Cum 161.58 170.00
@ 300MM THICK NON STRUCTURALWALL
RAFT SLAB LEVEL Cum 315.62 1.00 315.62
LOWER GROUND FLOOR LEVEL Cum 74.12 1.00 74.12
Total Cum 389.74 410.00
@ SHEAR WALL (M40)
UP TP GRADE SLAB Cum 205.18 1.00 205.18
BASEMENT LEVEL Cum 928.08 1.00 928.08
LOWER GROUND FLOOR LEVEL Cum 1243.63 1.00 1243.63
GROUND FLOOR LVL Cum 214.10 1.00 214.10
FIRST FLOOR LVL Cum 241.82 1.00 241.82
SECOND FLOOR LVL Cum 171.61 1.00 171.61
THIRD FLOOR LVL Cum 172.24 1.00 172.24
FOURTH FLOOR LVL Cum 135.29 1.00 135.29
TOP FLOOR LVL Cum 123.66 1.00 123.66
Total Cum 3435.59 3608.00
@ FLOOR BEAM (M40)
RAFT SLAB LEVEL Cum 27.73 1.00 27.73
Total Cum 27.73 30.00
LOWER GROUND FLOOR Cum 89.27 1.00 89.27
GROUND FLOOR Cum 23.75 1.00 23.75
FIRST FLOOR Cum 23.75 1.00 23.75
SECOND FLOOR Cum 23.75 1.00 23.75
THIRD FLOOR Cum 23.75 1.00 23.75
FOURTH FLOOR Cum 17.90 1.00 17.90
TOP FLOOR Cum 16.78 1.00 16.78
Total Cum 218.96 230.00
@ 250 MM THICK RCC SLAB (M40)
LOWER GROUND FLOOR LEVEL Cum 451.90 1.00 451.90
Total Cum 451.90 475.00
Gorund Floor Level Cum 241.08 1.00 241.08
FIRST FLOOR LEVEL Cum 255.34 1.00 255.34
SECOND FLOOR LEVEL Cum 214.85 1.00 214.85
THIRD FLOOR LEVEL Cum 136.79 1.00 136.79
FOURTH FLOOR LEVEL Cum 265.65 1.00 265.65
TOP FLOOR LEVEL Cum 69.52 1.00 69.52
Total Cum 1183.22 1243.00
Gorund Floor Level Sqm 1205.38 1.00 1205.38
FIRST FLOOR LEVEL Sqm 1276.69 1.00 1276.69
SECOND FLOOR LEVEL Sqm 1074.24 1.00 1074.24
THIRD FLOOR LEVEL Sqm 683.93 1.00 683.93
FOURTH FLOOR LEVEL Sqm 1328.26 1.00 1328.26
TOP FLOOR LEVEL Sqm 347.60 1.00 347.60
Total Sqm 5916.10 6212.00
RAFT SLAB LVL TO LGL Cum 12.69 1.00 12.69
BASEMENT TO FOURTH FLOOR Cum 144.45 1.00 144.45
Total Cum 157.13 165.00
Total OF M40 GRADE Cum 10,566.55 11,095.00
@ STEEL BEAM (STRUCTURAL STEEL)
GROUND FLOOR LEVEL kg 1.00 0.00
FIRST FLOOR LEVEL kg 1.00 0.00
SECOND FLOOR LEVEL kg 1.00 0.00
THIRD FLOOR LEVEL kg 1.00 0.00
FOURTH FLOOR LEVEL kg 1.00 0.00
TOP FLOOR LEVEL kg 1.00 0.00
Total kg 0.00 0.00
Total MT 0.00 0.00
@ STEEL BEAM PAINT
GROUND FLOOR LEVEL Sqm 0.00 1.00 0.00
FIRST FLOOR LEVEL Sqm 0.00 1.00 0.00
SECOND FLOOR LEVEL Sqm 0.00 1.00 0.00
THIRD FLOOR LEVEL Sqm 0.00 1.00 0.00
FOURTH FLOOR LEVEL Sqm 0.00 1.00 0.00
TOP FLOOR LEVEL Sqm 0.00 1.00 0.00
Total Sqm 0.00 0.00
GROUND FLOOR LEVEL kg 255,540.58 1.00 255,540.58
FIRST FLOOR LEVEL kg 257,654.80 1.00 257,654.80
SECOND FLOOR LEVEL kg 244,629.00 1.00 244,629.00
THIRD FLOOR LEVEL kg 124,025.21 1.00 124,025.21
FOURTH FLOOR LEVEL kg 285,867.66 1.00 285,867.66
TOP FLOOR LEVEL kg 51,753.42 1.00 51,753.42
@ STEEL BEAM PAINT
GROUND FLOOR LEVEL Sqm 1,863.52 1.00 1,863.52
FIRST FLOOR LEVEL Sqm 1,880.24 1.00 1,880.24
SECOND FLOOR LEVEL Sqm 1,804.68 1.00 1,804.68
THIRD FLOOR LEVEL Sqm 1,002.99 1.00 1,002.99
FOURTH FLOOR LEVEL Sqm 3,057.51 1.00 3,057.51
TOP FLOOR LEVEL Sqm 454.64 1.00 454.64
@ Footing Pile Cap
Total Sqm 1265.65 1393.00
UP TO GRADE SLAB Sqm 152.15 1.00 152.15
BASMENT FLOOR Sqm 710.01 1.00 710.01
RAFT SLAB LEVEL(LOWER GROUND FLOOR) Sqm 970.83 1.00 970.83
GROUND FLOOR Sqm 970.83 1.00 970.83
FIRST FLOOR Sqm 970.83 1.00 970.83
SECOND FLOOR Sqm 710.01 1.00 710.01
THIRD FLOOR Sqm 710.01 1.00 710.01
FOURTH FLOOR Sqm 724.50 1.00 724.50
Total Sqm 5919.17 6512.00
@ WATER TANK WALL
300MM THICK NON STRUCTURALWALL
RAFT SLAB LEVEL Sqm 1077.21 1.00 1077.21
Total Sqm 1077.21 1185.00
@ 300MM THICK NON STRUCTURALWALL
RAFT SLAB LEVEL Sqm 2104.14 1.00 2104.14
LOWER GROUND FLOOR LEVEL Sqm 494.11 1.00 494.11
Total Sqm 2598.25 2859.00
UP TO GRADE SLAB Sqm 850.19 1.00 850.19
BASEMENT LEVEL Sqm 3903.58 1.00 3903.58
LOWER GROUND FLOOR LEVEL Sqm 5137.50 1.00 5137.50
GROUND FLOOR LVL Sqm 1280.54 1.00 1280.54
FIRST FLOOR LVL Sqm 1465.35 1.00 1465.35
SECOND FLOOR LVL Sqm 1040.23 1.00 1040.23
THIRD FLOOR LVL Sqm 1044.42 1.00 1044.42
FOURTH FLOOR LVL Sqm 795.72 1.00 795.72
TOP FLOOR LVL Sqm 727.73 1.00 727.73
RAFT SLAB LEVEL Sqm 187.00 1.00 187.00
Total Sqm 187.00 206.00
LOWER GROUND FLOOR Sqm 765.25 1.00 765.25
GROUND FLOOR Sqm 200.46 1.00 200.46
FIRST FLOOR Sqm 200.46 1.00 200.46
SECOND FLOOR Sqm 200.46 1.00 200.46
THIRD FLOOR Sqm 200.46 1.00 200.46
FOURTH FLOOR Sqm 150.79 1.00 150.79
TOP FLOOR Sqm 140.87 1.00 140.87
Total Sqm 1858.76 2045.00
@ 250 MM THICK RCC SLAB (M40)
LOWER GROUND FLOOR LEVEL Sqm 1807.60 1.00 1807.60
Total Sqm 1807.60 1989.00
Gorund Floor Level Sqm 1205.38 1.00 1205.38
FIRST FLOOR LEVEL Sqm 1276.69 1.00 1276.69
SECOND FLOOR LEVEL Sqm 1074.24 1.00 1074.24
THIRD FLOOR LEVEL Sqm 683.93 1.00 683.93
FOURTH FLOOR LEVEL Sqm 1328.26 1.00 1328.26
TOP FLOOR LEVEL Sqm 347.60 1.00 347.60
Total Sqm 5916.10 6508.00
BASEMENT TO FOURTH FLOOR Sqm 83.78 1.00 83.78
BASEMENT TO FOURTH FLOOR Sqm 681.61 1.00 681.61
Total Sqm 765.39 842.00
3 REINFORCEMENT KG/CUM
RETAINING WALL 100.00 0
SALB BEAM & MAIN BEAM 300.00 218.96 65689.4505
RCC SLAB 80.00 0
15 PRECAST PANELS Cum 703.03 1.00 703.03
Total Cum 703.03 739.00
SuPr ENGINEERING & CONSULATANT 307,SIDDHARTH UPSCALE VASANA ROAD VADODARA-390007 MEASUREMENT
VADODARA ARCHITECT:-
DATE : 24.09.2024 CLIENT:-
PREPARED BY : CHECKED BY :
SR.NO. PARTICULARS NO. L B D / H QTY.
J BLOCK N.G.L 50.00
J BLOCK LEVEL 48.00 GRADE SLAB = 0.25
Mass excavation 2.00 GSB = 0.25
Pile cap bottom level 45.65 PCC = 0.15
Excavation for pile cap 2.35 0.1
Drg No :- Depht- 1.50 mt
Mass excavation for lower Ground floor level
Drg No :- Depht- 1.50 mt
Mass excavation for lower Ground floor level
BLOCK J 1.0 3388.36 P-area 1.50 5082.54 till 2m from o.o level
Drg No :- Depht- 1.50 mt
Drg No :- Depht- 1.50 mt
1.1.11 EXCAVATION FOR PILE 600MM DIA
Drg No :- Depht- 16.00 mt
J1A, J1B, J2A, J2B, J3A, J3B, J4A, J4B, J5A, J5B,J6A, J6B, J7A, J7B, J8A, J8B, J9A, J9B,J10A, J10B, J11A, J11B, J12A, J12B, J13A, J13B,J14A, J14B, J15A, J15B, J16A, J16B, J17A, J17B,J18A, J18B, J19A, J19B, J20A, J20B, J21A, J21B 378.0 16.00 6048.00
DOMESTIC TANK 02 21.0 16.00 336.00
PERIPHERY 108.0 16.00 1728.00
1.2 BACK FILLING
Drg Title :- NA
Total EXCAVATION 1.0 15925.29 Qty 15925.29
Ded of grade slab -1.0 367.55 -367.55
Ded of pcc below grade slab -1.0 511.59 -511.59
Ded of columns -1.0 59.54 -59.54
Ded od pile cap -1.0 1856.94 -1856.94
Ded of shear wall -1.0 205.18 -205.18
Ded of ns wall -1.0 113.87 -113.87
1.3 ANTITERMITE TREATMENT
RAFT SLAB LEVELFLOOR
Drg Title : RAFT SLAB LEVEL FLOOR
BLOCK J 1.0 2633.75 P-area 2633.75
@ FOOTING LEVEL
Drg Title :- NA
Drg No :- BGA/GVM/STR-101
J1A, J1B, J2A, J2B, J3A, J3B, J4A, J4B, J5A, J5B,J6A, J6B, J7A, J7B, J8A, J8B, J9A, J9B,J10A, J10B, J11A, J11B, J12A, J12B, J13A, J13B,J14A, J14B, J15A, J15B, J16A, J16B, J17A, J17B,J18A, J18B, J19A, J19B, J20A, J20B, J21A, J21B 21.0 4.20 8.70 0.15 115.10
@ PCC BELOW GRADE SLAB
@ FOOTING LEVEL
Drg No :- BGA/GVM/STR-101
Lower Ground Level
Drg Title :- NA
Drg No :- BGA/GVM/STR-101
deduction for pile cap -1.0 1375.51 0.45 -618.98
@ RUBBLE SOLING
@ FOOTING LEVEL
Drg Title :- NA
2.1 CONCRETE WORK
@ Footing Pile Cap
J1A, J1B, J2A, J2B, J3A, J3B, J4A, J4B, J5A, J5B,J6A, J6B, J7A, J7B, J8A, J8B, J9A, J9B,J10A, J10B, J11A, J11B, J12A, J12B, J13A, J13B,J14A, J14B, J15A, J15B, J16A, J16B, J17A, J17B,J18A, J18B, J19A, J19B, J20A, J20B, J21A, J21B 21.0 3.90 8.40 1.35 928.75 697.41
HVAC TANK 1 43.2 P-AREA 1.35 58.33 42.42
@ Pile Concrete (M40)
J1A, J1B, J2A, J2B, J3A, J3B, J4A, J4B, J5A, J5B,J6A, J6B, J7A, J7B, J8A, J8B, J9A, J9B,J10A, J10B, J11A, J11B, J12A, J12B, J13A, J13B,J14A, J14B, J15A, J15B, J16A, J16B, J17A, J17B,J18A, J18B, J19A, J19B, J20A, J20B, J21A, J21B 378.0 0.79 0.36 16.00 1709.16
CHIPING BREAKING PILE HEAD
@ Column up to raft Slab Level
UP TO RAFT SLAB LVL
Drg No :- HT 0.60
Drg No :- NA SLB THK 0.00
Drg Date:- 0.60
@ RCC COLUMN (M40)
RAFT SLAB LEVEL(LOWER GROUND FLOOR)
Drg No :- HT 3.60
Drg No :- NA SLB THK -0.25
Drg Date:- 3.35
Drg No :- HT 6.00
Drg No :- NA SLB THK -0.25
Drg Date:- 5.75
Drg No :- HT 7.20
Drg No :- NA SLB THK -0.20
Drg Date:- 7.00
Drg No :- NA HT 4.95
Drg Date:- SLB THK -0.20
THIRD FLOOR HT 4.00
Drg No :- SLB THK -0.20
Drg No :- NA 3.80
FOURTH FLOOR HT 5.20
Drg No :- SLB THK -0.20
Drg No :- NA 5.00
WATER TANK WALL
@ 300MM THICK NON STRUCTURALWALL
FRESH AIR PASSAGE 1.0 1.50 0.30 1.05 0.47 3.15
ENTRANCE LOBBY 1.0 4.44 0.30 1.05 1.40 9.32
WATER TANK WALL
@ 300MM THICK NON STRUCTURALWALL
RAFT SLAB LEVEL
@ 300MM THICK NON STRUCTURALWALL
RAFT SLAB LEVEL
FRESH AIR PASSAGE 1.0 1.50 0.30 4.90 2.21 14.70
@ 300MM THICK NON STRUCTURALWALL
LOWER GROUND FLOOR LEVEL
GRADE OF CONCRETE M40
RAFT SLAB LEVEL
GRADE OF CONCRETE M40
GRADE OF CONCRETE M40
LOWER GROUND FLOOR LEVEL
GROUND FLOOR LVL HT 6.00
Drg Title :- SLAB -0.15
Drg No :- NA 6.15
FIRST FLOOR LVL HT 7.20
Drg Title :- SLAB -0.20
Drg No :- NA 7.40
SECOND FLOOR LVL
THIRD FLOOR LVL
FOURTH FLOOR LVL
@ RCC FLOOR BEAM
GRADE OF CONCRETE M40
RAFT SLAB LEVEL
LOWER GROUND FLOOR
Beam Depth 0.60 Beam Depth 0.90
Slab Thk. -0.25 Slab Thk.
Beam Depth 0.60 Beam Depth 1.00
Slab Thk. -0.20 Slab Thk.
Beam Depth 0.60 Beam Depth 0.75
Slab Thk. -0.23 Slab Thk.
Beam Depth 0.60 Beam Depth 0.80
Slab Thk. -0.15 Slab Thk.
Beam Depth 0.75 Beam Depth 0.50
Slab Thk. -0.25 Slab Thk. -0.15
Beam Depth 0.60 Beam Depth 0.75
Slab Thk. -0.15 Slab Thk. -0.15
Beam Depth 1.00
Slab Thk. -0.15
Beam Depth 0.60 Beam Depth 0.75
Slab Thk. -0.15 Slab Thk. -0.15
Beam Depth 1.00
Slab Thk. -0.15
Beam Depth 0.60 Beam Depth 1.00
Slab Thk. -0.15 Slab Thk. -0.15
Beam Depth 0.75 Beam Depth 0.90
Slab Thk. -0.15 Slab Thk. -0.15
@ 250 MM THICK RCC SLAB (M40)
LOWER GROUND FLOOR LEVEL
STAIRCASE -2.0 39.80 P-AREA 0.25 -19.90 -79.60
Gorund Floor Level
Drg Title :- 20240916_MORKI_DD
STAIRCASE -2.0 39.80 P-AREA 0.20 -15.92 -79.60
CUTOUT & STAIRCASE DED -1.0 77.90 P-AREA 0.20 -15.58 -77.90
FIRST FLOOR LEVEL
STAIRCASE -2.0 39.80 P-AREA 0.20 -15.92 -79.60
CUTOUT DED -1.0 35.83 P-AREA 0.20 -7.17 -35.83
CUTOUT DED -1.0 12.40 P-AREA 0.20 -2.48 -12.40
SECOND FLOOR LEVEL
STAIRCASE -2.0 39.80 P-AREA 0.20 -15.92 -79.60
CUTOUT DED -1.0 14.66 P-AREA 0.20 -2.93 -14.66
CUTOUT DED -1.0 19.84 P-AREA 0.20 -3.97 -19.84
CUTOUT DED -1.0 14.80 P-AREA 0.20 -2.96 -14.80
THIRD FLOOR LEVEL
STAIRCASE -2.0 39.80 P-AREA 0.20 -15.92 -79.60
CUTOUT DED -1.0 7.81 P-AREA 0.20 -1.56 -7.81
CUTOUT DED -1.0 18.75 P-AREA 0.20 -3.75 -18.75
FOURTH FLOOR LEVEL
STAIRCASE -2.0 39.80 P-AREA 0.20 -15.92 -79.60
CUTOUT DED -1.0 35.55 P-AREA 0.20 -7.11 -35.55
CUTOUT DED -1.0 19.89 P-AREA 0.20 -3.98 -19.89
TOP FLOOR LEVEL
STAIRCASE -2.0 39.80 P-AREA 0.20 -15.92 -79.60
Drg Title : Staircase Detail
Between grid BDY2 TO BY1
Staircase from Raft Slab Level to lower Ground floor
Landing 2.00 8.69 (area) 0.15 2.61
Staircase from Raft Slab Level to lower Ground floor
Landing 1.00 7.38 (area) 0.15 1.11
Drg Title : Staircase Detail
Drg Date. 25-09-2024
GRID J R1 TO J R3
Staircase from Lower Ground Level to Ground Level
Landing 2.00 8.12 (area) 0.15 2.43
SAME AS OTHER SIDE 14.32 14.32
Staircase from Ground Level to First Floor
Landing 4.00 8.12 (area) 0.15 4.87
SAME AS OTHER SIDE 15.23 15.23
Staircase from Lower First Floor to second floor
Landing 4.00 8.12 (area) 0.15 4.87
SAME AS OTHER SIDE 16.25 16.25
Staircase from second floor to third floor
Landing 4.00 8.12 (area) 0.15 4.87
SAME AS OTHER SIDE 13.21 13.21
Staircase from Third floor to Fourth floor
same as above 26.42 26.42
Staircase Shuttering
Drg Title : Staircase Detail
Drg Date. 25-09-2024
Staircase from Raft Slab Level to lower Ground floor
Landing 2.00 8.69 (area) 17.38
Staircase from Raft Slab Level to lower Ground floor
Landing 1.00 7.38 (area) 7.38
Drg Title : Staircase Detail
Drg Date. 25-09-2024
GRID J R1 TO J R3
Staircase from Lower Ground Level to Ground Level
Landing 2.00 8.12 (area) 16.23
Same as other side 62.09 62.09
Staircase from Ground Level to First Floor
Landing 4.00 8.12 (area) 32.47
SAME AS OTHER SIDE 72.56 72.56
Staircase from Lower First Floor to second floor
Landing 4.00 8.12 (area) 32.47
SAME AS OTHER SIDE 76.40 76.40
Staircase from second floor to third floor
Landing 4.00 8.12 (area) 32.47
SAME AS OTHER SIDE 64.88 64.88
Staircase from Third floor to Fourth floor
same as above 129.75 129.75
GROUND FLOOR LEVEL
FIRST FLOOR LEVEL
HORIZONATAL MEMBER
SECOND FLOOR LEVEL
THIRD FLOOR LEVEL
FOURTH FLOOR LEVEL
TOP FLOOR LEVEL
14 PRECAST PANELS
avg top and bottom length
LOWER GROUND FLOOR
Drg Title : 2025-09-18_GVM_A4.ELIPTICAL AREA
Drg Date : 01-04-2026
Lower ground floor 1.0 160.46 0.15 7.01 168.67
Ded of Fresh air passage opn -1.0 2.75 0.15 2.49 -1.03
Ded of entrance lobby -1.0 5.10 0.15 2.95 -2.26
Ded of door from north block (D-J-L-02) -1.0 1.50 0.15 2.40 -0.54
Ded of Fresh air passage opn -1.0 2.75 0.15 6.90 -2.85
Ded of door from north block (D-J-G-01) -1.0 1.50 0.15 2.40 -0.54 3rd
Ded of Fresh air passage opn -1.0 2.75 0.15 6.90 -2.85
Ded of exit bridge -1.0 2.83 0.15 4.24 -1.80
Terrace floor 4.0 11.10 0.15 2.57 17.09
SuPr ENGINEERING & CONSULATANTS 307,SIDDHARTH UPSCALE VASANA ROAD VADODARA-390007 SUMMARY
VADODARA PROJECT : GUJARAT VANDANA MUSEUM, GUJARAT
DATE : 05-09-25 ARCHITECT : OPOLIS
PREPARED BY : d CLIENT : DIRECTORATE OF ARCHEOLOGY AND MUSEUMS, G.O.G
REV : CHECKED BY :
SR. NO. PARTICULAR UNIT Qty. Floor NO. Total QTY. WITH CONTIGENCY
1.1.2 EXCAVATION FOR PILE 600MM DIA RMT 1856.00 1.00 1856.00 1949.00
1.2 BACK FILLING Cum 133.37 1.00 133.37 141.00
1.3 ANTITERMITE TREATMENT
RAFT SLAB LEVELFLOOR Sqm 436.23 1.00 436.23
Total Sqm 436.23 480.00
Footing level Cum 53.52 1.00 53.52
Total Cum 53.52 57.00
Lower Ground Level Cum 65.43 1.00 65.43
Total Cum 65.43 69.00
FOOTING LEVEL Cum 109.06 1.00 109.06
Total Cum 109.06 115.00
2 STRUCTURAL WORK
2.1 CONCRETE WORK
@ Pile Concrete (M40)
Total Cum 524.51 551.00
@ Footing Pile Cap M40
Total Cum 109.03 115.00
@ CHIPING BREAKING PILE HEAD Cum 9.83 1.00 9.83
Total Cum 9.83 11.00
@ 600MM DIA PILE -SOCKETING LENGTH Rmt 0.00 1.00 0.00
Total Rmt 0.00 0.00
@ 600MM DIA PILE - EMPTY BORING Rmt 0.00 1.00 0.00
Total Rmt 0.00 0.00
@ Column up to Plinth (M40)
PLINTH BEAM LEVEL PLAN & FIRST SLAB LEVEL PLAN Cum 5.35 1.00 5.35
Total Cum 5.35 6.00
PLINTH BEAM LEVEL PLAN & FIRST SLAB LEVEL PLAN Cum 19.74 1.00 19.74
Total Cum 19.74 21.00
@ RCC PLINTH BEAM
PINTH BEAM LEVEL PLAN Cum 59.08 1.00 59.08
Total Cum 59.08 63.00
@ RCC SLAB BEAM
FIRST SLAB LEVEL Cum 32.99 1.00 32.99
Total Cum 32.99 35.00
@ 125 MM THICK RCC SLAB (M40)
PLINTH BEAM LEVEL PLAN & FIRST SLAB LEVEL PLAN Cum 15.11 1.00 15.11
Total Cum 15.11 16.00
@ 150 MM THICK RCC SLAB (M40)
PLINTH BEAM LEVEL PLAN & FIRST SLAB LEVEL PLAN Cum 43.50 1.00 43.50
Total Cum 43.50 46.00
Total OF M40 GRADE Cum 874.75 919.00
PLINTH BEAM LEVEL PLAN & FIRST SLAB LEVEL PLAN Sqm 14.44 1.00 14.44
Total Sqm 14.44 16.00
PLINTH BEAM LEVEL PLAN kg 392.58 1.00 392.58
Total kg 392.58 413.00
Total MT 0.39 1.00
@ STEEL BEAM PAINT
PLINTH BEAM LEVEL PLAN Sqm 12.54 1.00 12.54
Total Sqm 12.54 14.00
PLINTH BEAM LEVEL PLAN kg 351.90 1.00 351.90
Total kg 351.90 370.00
Total MT 0.35 1.00
@ STEEL COLUMN PAINT
PLINTH BEAM LEVEL PLAN kg 27.00 1.00 27.00
Total kg 27.00 29.00
@ 10 MM THICK BASE PLATE
10 MM THICK BASE PLATE Sqm 196.00 1.00 196.00
Total Sqm 196.00 206.00
@ 16MM DIA CHEMICAL FASTNERS
PLINTH BEAM LEVEL PLAN & FIRST SLAB LEVEL PLAN NOS 40.00 1.00 40.00
Total NOS 40.00 42.00
@ 8MM THICK STIFFNER PLATE (FOUR SIDE)
PLINTH BEAM LEVEL PLAN & FIRST SLAB LEVEL PLAN KG 150.72 1.00 150.72
Total KG 150.72 159.00
@ Footing Pile Cap M40
Total Sqm 383.76 403.00
@ RCC COLUMN UP TO PLINTH (M40) Sqm 53.40 1.00 53.40
Total Sqm 53.40 57.00
PLINTH BEAM LEVEL PLAN & FIRST SLAB LEVEL PLAN Sqm 203.41 1.00 203.41
Total Sqm 203.41 214.00
@ RCC PLINTH BEAM
PINTH BEAM LEVEL PLAN Sqm 388.69 1.00 388.69
Total Sqm 388.69 409.00
@ SALB BEAM & MAIN BEAM
FIRST SLAB LEVEL Sqm 258.96 1.00 258.96
Total Sqm 258.96 272.00
@ 125 MM THICK RCC SLAB (M40)
PLINTH BEAM LEVEL PLAN & FIRST SLAB LEVEL PLAN Sqm 120.88 1.00 120.88
Total Sqm 120.88 127.00
@ 150 MM THICK RCC SLAB (M40)
PLINTH BEAM LEVEL PLAN & FIRST SLAB LEVEL PLAN Sqm 290.00 1.00 290.00
Total Sqm 290.00 305.00
PLINTH BEAM LEVEL PLAN & FIRST SLAB LEVEL PLAN Sqm 0.00 1.00 0.00
Total Sqm 0.00 0.00
3 REINFORCEMENT KG/CUM
SALB BEAM & MAIN BEAM 300.00 32.99 9897.6975
DECK SLAB 40.00 16.00 640
Total MT 136.09 143.00
SuPr ENGINEERING & CONSULATANT 307,SIDDHARTH UPSCALE VASANA ROAD VADODARA-390007 MEASUREMENT
VADODARA ARCHITECT:-
DATE : 24.09.2024 CLIENT:-
PREPARED BY : CHECKED BY :
SR.NO. PARTICULARS NO. L B D / H QTY.
Drg No :- Depht- 1.50 mt
Mass excavation for lower Ground floor level
SECURITY CABIN 1 4.0 1.50 1.90 1.50 17.10
SECURITY CABIN 2 4.0 1.50 1.90 1.50 17.10
SECURITY CABIN 3 4.0 1.50 1.90 1.50 17.10
SECURITY CABIN 4 4.0 1.50 1.90 1.50 17.10
SECURITY CABIN 5 4.0 1.50 1.90 1.50 17.10
TICKETING BLOCK 32.0 1.50 1.90 1.50 136.80
COVERED WALKWAY 1.0 3.20 16.45 1.50 78.96
1.1.2 EXCAVATION FOR PILE 600MM DIA
Drg No :- Depht- 16.00 mt
SECURITY CABIN 1
SECURITY CABIN 2
SECURITY CABIN 3
SECURITY CABIN 4
SECURITY CABIN 5
TICKETING BLOCK
COVERED WALKWAY
1.1.3 EXCAVATION FOR PILE CAP
SECURITY CABIN 1
SECURITY CABIN 2
SECURITY CABIN 3
SECURITY CABIN 4
SECURITY CABIN 5
TICKETING BLOCK
COVERED WALKWAY
1.2 BACK FILLING
Drg Title :- NA
Total excavtion 1.0 301.26 Qty 301.26
ded of pcc below footing -1.0 53.52 -53.52
ded of footing -1.0 109.03 -109.03
ded of column at footing level -1.0 5.35 -5.35
1.3 ANTITERMITE TREATMENT
RAFT SLAB LEVELFLOOR
Drg Title : RAFT SLAB LEVELFLOOR
SECURITY CABIN 1 1.0 4.78 5.10 24.35
SECURITY CABIN 2 1.0 3.80 3.80 14.44
SECURITY CABIN 3 1.0 5.25 6.05 31.76
SECURITY CABIN 4 1.0 6.05 4.70 28.44
SECURITY CABIN 5 1.0 2.45 5.60 13.72
TICKETING BLOCK 1.0 8.05 33.65 270.88
COVERED WALKWAY 1.0 3.20 16.45 52.64
@ FOOTING LEVEL
Drg Title :- NA
SECURITY CABIN 1
SECURITY CABIN 2
SECURITY CABIN 3
SECURITY CABIN 4
SECURITY CABIN 5
TICKETING BLOCK
COVERED WALKWAY
MASS PCC ON FLOOR
SECURITY CABIN 1 1.0 4.78 5.10 0.10 2.44
SECURITY CABIN 2 1.0 3.80 3.80 0.10 1.44
SECURITY CABIN 3 1.0 5.25 6.05 0.10 3.18
SECURITY CABIN 4 1.0 6.05 4.70 0.10 2.84
SECURITY CABIN 5 1.0 2.45 5.60 0.10 1.37
TICKETING BLOCK 1.0 8.05 33.65 0.10 27.09
COVERED WALKWAY 1.0 3.20 16.45 0.10 5.26
Lower Ground Level
Drg Title :- NA
Drg No :- BGA/GVM/STR-101
SECURITY CABIN 1 1.0 4.78 5.10 0.15 3.65
SECURITY CABIN 2 1.0 3.80 3.80 0.15 2.17
SECURITY CABIN 3 1.0 5.25 6.05 0.15 4.76
SECURITY CABIN 4 1.0 6.05 4.70 0.15 4.27
SECURITY CABIN 5 1.0 2.45 5.60 0.15 2.06
TICKETING BLOCK 1.0 8.05 33.65 0.15 40.63
COVERED WALKWAY 1.0 3.20 16.45 0.15 7.90
@ FOOTING LEVEL
Drg Title :- NA
SECURITY CABIN 1 1.0 4.78 5.10 0.25 6.09
SECURITY CABIN 2 1.0 3.80 3.80 0.25 3.61
SECURITY CABIN 3 1.0 5.25 6.05 0.25 7.94
SECURITY CABIN 4 1.0 6.05 4.70 0.25 7.11
SECURITY CABIN 5 1.0 2.45 5.60 0.25 3.43
TICKETING BLOCK 1.0 8.05 33.65 0.25 67.72
COVERED WALKWAY 1.0 3.20 16.45 0.25 13.16
2.1 CONCRETE WORK
@ Footing Pile Cap M40
SECURITY CABIN 1
SECURITY CABIN 2
SECURITY CABIN 3
SECURITY CABIN 4
SECURITY CABIN 5
TICKETING BLOCK
COVERED WALKWAY
@ Pile Concrete (M40)
SECURITY CABIN 1 5.0 0.79 0.36 16.00 22.61
SECURITY CABIN 2 4.0 0.79 0.36 16.00 18.09
SECURITY CABIN 3 4.0 0.79 0.36 16.00 18.09
SECURITY CABIN 4 4.0 0.79 0.36 16.00 18.09
SECURITY CABIN 5 4.0 0.79 0.36 16.00 18.09
TICKETING BLOCK 23.0 0.79 0.36 16.00 104.00
COVERED WALKWAY
CHIPING BREAKING PILE HEAD
600MM DIA PILE -SOCKETING LENGTH
TOTAL PILE 116.0 0.00 0.00
600MM DIA PILE - EMPTY BORING
TOTAL PILE 116.0 0.00 0.00
@ RCC COLUMN UP TO PLINTH (M40)
PLINTH BEAM LEVEL PLAN & FIRST SLAB LEVEL PLAN
SECURITY CABIN 1
SECURITY CABIN 2
SECURITY CABIN 3
SECURITY CABIN 4
SECURITY CABIN 5
PLINTH BEAM LEVEL PLAN & FIRST SLAB LEVEL PLAN
Drg No :- HT 3.00
Drg No :- NA SLB THK -0.125
Drg Date:- 2.88
SECURITY CABIN 1
SECURITY CABIN 2
SECURITY CABIN 3
SECURITY CABIN 4
SECURITY CABIN 5
TICKETING BLOCK
@ RCC PLINTH BEAM
GRADE OF CONCRETE M40
PINTH BEAM LEVEL PLAN
SECURITY CABIN 1
SECURITY CABIN 2
SECURITY CABIN 3
SECURITY CABIN 4
SECURITY CABIN 5
TICKETING BLOCK
FIRST SLAB LEVEL
SECURITY CABIN 1
SECURITY CABIN 3
SECURITY CABIN 4
SECURITY CABIN 5
TICKETING BLOCK
@ 125 MM THICK RCC SLAB (M40)
PLINTH BEAM LEVEL PLAN & FIRST SLAB LEVEL PLAN
@ 150 MM THICK RCC SLAB (M40)
PLINTH BEAM LEVEL PLAN & FIRST SLAB LEVEL PLAN
TICKETING COUNTER 1.0 8.60 34.20 0.15 44.12 294.12
PLINTH BEAM LEVEL PLAN & FIRST SLAB LEVEL PLAN
SECURITY CABIN 2
DECK SLAB 1.0 14.44 P-AREA 14.44
PLINTH BEAM LEVEL PLAN
Drg No :- BGA/GVM/STR-03
SECURITY CABIN 2
STEEL (MS)COLUMN
PLINTH BEAM LEVEL PLAN
SECURITY CABIN 2 0.90
TICKETING BLOCK 0.90
10 MM THICK BASE PLATE
PLINTH BEAM LEVEL PLAN & FIRST SLAB LEVEL PLAN
16MM DIA CHEMICAL FASTNERS
PLINTH BEAM LEVEL PLAN & FIRST SLAB LEVEL PLAN
8MM THICK STIFFNER PLATE (FOUR SIDE)
PLINTH BEAM LEVEL PLAN & FIRST SLAB LEVEL PLAN
SuPr ENGINEERING & CONSULATANTS 307,SIDDHARTH UPSCALE VASANA ROAD VADODARA-390007 SUMMARY
VADODARA PROJECT : GUJARAT VANDANA MUSEUM, GUJARAT
DATE : 05-09-25 ARCHITECT : OPOLIS
PREPARED BY : d CLIENT : DIRECTORATE OF ARCHEOLOGY AND MUSEUMS, G.O.G
REV : CHECKED BY :
SR. NO. PARTICULAR UNIT Qty. Floor NO. Total QTY. WITH CONTIGENCY
PCC BELOW FLOOR BEAM Cum 128.33 1.00 128.33
Total Cum 128.33 135.00
2 STRUCTURAL WORK
2.1 CONCRETE WORK
Total Cum 263.22 277.00
COMPOUND WALL ELV
Total Cum 142.60 150.00
@ RCC Column (M40)
COMPOUND WALL ELV Cum 21.94 1.00 21.94
Total Cum 21.94 24.00
200 MM BLOCK WORK
@ COMPOUND WALL ELV
Total Sqm 414.45 436.00
@ SANDFACE PLASTER WITH TEXTURE PAINT
COMPOUND WALL ELV Sqm 4556.69 1.00 4556.69
Total Sqm 4556.69 4785.00
@ 50MM THICK GRANITE AS PER SELECTION
COMPOUND WALL ELV SQM 218.19 1.00 218.19
Total SQM 218.19 230.00
GI MESH 1200 MM HT FENCEING
Total Rmt 420.97 443.00
GI MESH 2000 MM HT FENCEING
Total Rmt 410.13 431.00
SS FLAT FENCING
Total Rmt 259.83 273.00
Total Sqm 701.93 738.00
COMPOUND WALL ELV Sqm 987.23 1.00 987.23
Total Sqm 1426.00 1498.00
COMPOUND WALL ELV Sqm 438.70 1.00 438.70
Total Sqm 438.70 461.00
3 REINFORCEMENT KG/CUM
Total MT 88.84 94.00
@ WATERBODY WATERPROOFING Sqm 432.37 1.00 432.37
Total Sqm 432.37 476.00
@ EXPANSION JOINT Rmt 608.00 1.00 608.00
Total Rmt 608.00 0.00
SuPr ENGINEERING & CONSULATANT 307,SIDDHARTH UPSCALE VASANA ROAD VADODARA-390007 MEASUREMENT
VADODARA ARCHITECT:-
DATE : 24.09.2024 CLIENT:-
PREPARED BY : CHECKED BY :
SR.NO. PARTICULARS NO. L B D / H QTY.
Drg No :- Depht- 0.65 mt
FOR COMPOUND WALL
Footing Excavation 235 2.40 3.20 0.50 903.22
Landscape 1.0 10537.00 P-area 1.50 15805.50
1.2 BACK FILLING
Drg Title :- NA
Total excavtion 1.0 1565.34 Qty 1565.34
ded of pcc below footing -1.0 98.72 -98.72
ded of BEAM at footing level -1.0 128.33 -128.33
Ded of footing -1.0 9.35 -9.35
PCC BELOW FLOOR BEAM
BELOW FOOTING 274 1.40 2.20 0.10 84.45
STRUCTURAL WORK
GRADE OF CONCRETE M40
COMPOUND WALL ELV
GRADE OF CONCRETE M40
COMPOUND WALL ELV
GRADE OF CONCRETE M40
COMPOUND WALL ELV
COMPOUND WALL ELV
@ 200 MM BLOCK WORK
COMPOUND WALL ELV
@ SANDFACE PLASTER WITH TEXTURE PAINT
COMPOUND WALL ELV
50MM THICK GRANITE AS PER SELECTION
COMPOUND WALL ELV
GI MESH 1200 MM HT FENCEING
COMPOUND WALL ELV
GI MESH 2000 MM HT FENCEING
COMPOUND WALL ELV
COMPOUND WALL ELV
@ WATERBODY WATERPROOFING
@ EXPANSION JOINT
SuPr ENGINEERING CONSULTANTS 307, SIDDHARTH UPSCALE, VASNA ROAD VADODARA-390007 TEL- 0265-3149701 SUMMARY
VADODARA PROJECT : GUJARAT VANDANA MUSEUM, GUJARAT
DATE : 05-09-25 ARCHITECT : OPOLIS
PREPARED BY : MANDIPSINH CLIENT : DIRECTORATE OF ARCHEOLOGY AND MUSEUMS, G.O.G
SR. NO. PARTICULAR UNIT QTY. NO. OF FLOORS TOTAL QTY. QTY. WITH CONTIGENCY
R0 DWGS-RECD-07.07.25
2 MASONRY WORK (FLY ASH WALL)
2.1 100MM THICK FLY BLOCK MASONRY CODE-A13-01 & 1/A13-08
Basement Floor Cum 0.00 1.00 0.00
Lower Ground Floor Cum 0.00 1.00 0.00
Mezzanine Floor Cum 0.00 1.00 0.00
Ground Floor Cum 0.00 1.00 0.00
First Floor Cum 0.00 1.00 0.00
Mezzanine Floor Cum 0.00 1.00 0.00
Second Floor Cum 0.00 1.00 0.00
Third Floor Cum 0.00 1.00 0.00
Fourth Floor Cum 0.00 1.00 0.00
Total Cum 0.00 0.00
2.2 125MM THICK FLY BLOCK MASONRY CODE-A13-01 & 1/A13-08
Basement Floor Cum 0.00 1.00 0.00
Lower Ground Floor Cum 0.00 1.00 0.00
Mezzanine Floor Cum 0.00 1.00 0.00
Ground Floor Cum 0.00 1.00 0.00
First Floor Cum 0.00 1.00 0.00
Mezzanine Floor Cum 0.00 1.00 0.00
Second Floor Cum 0.00 1.00 0.00
Third Floor Cum 0.00 1.00 0.00
Fourth Floor Cum 0.00 1.00 0.00
Total Cum 0.00 0.00
2.3 150MM THICK FLY BLOCK MASONRY CODE-A13-01 & 1/A13-08
Basement Floor Cum 0.00 1.00 0.00
Lower Ground Floor Cum 0.16 1.00 0.16
Mezzanine Floor Cum 0.00 1.00 0.00
Ground Floor Cum 6.86 1.00 6.86
First Floor Cum 0.00 1.00 0.00
Mezzanine Floor Cum 0.00 1.00 0.00
Second Floor Cum 0.00 1.00 0.00
Third Floor Cum 0.00 1.00 0.00
Fourth Floor Cum 0.00 1.00 0.00
Total Cum 7.02 8.00
2.4 200MM THICK FLY BLOCK MASONRY CODE-A13-01 & 1/A13-08
Basement Floor Cum 0.00 1.00 0.00
Lower Ground Floor Cum 0.00 1.00 0.00
Mezzanine Floor Cum 0.00 1.00 0.00
Ground Floor Cum 20.01 1.00 20.01
First Floor Cum 0.00 1.00 0.00
Mezzanine Floor Cum 0.00 1.00 0.00
Second Floor Cum 2.73 1.00 2.73
Third Floor Cum 0.00 1.00 0.00
Fourth Floor Cum 0.00 1.00 0.00
Total Cum 22.74 24.00
2.5 250MM THICK FLY BLOCK MASONRY CODE-A13-01 & 1/A13-08
Basement Floor Cum 0.00 1.00 0.00
Lower Ground Floor Cum 2.10 1.00 2.10
Mezzanine Floor Cum 0.00 1.00 0.00
Ground Floor Cum 285.64 1.00 285.64
First Floor Cum 138.06 1.00 138.06
Mezzanine Floor Cum 0.00 1.00 0.00
Second Floor Cum 0.00 1.00 0.00
Third Floor Cum 0.00 1.00 0.00
Fourth Floor Cum 0.00 1.00 0.00
Total Cum 425.81 448.00
2.6 300MM THICK FLY BLOCK MASONRY CODE-A13-01 & 1/A13-08
Basement Floor Cum 0.00 1.00 0.00
Lower Ground Floor Cum 17.54 1.00 17.54
Mezzanine Floor Cum 0.00 1.00 0.00
Ground Floor Cum 0.00 1.00 0.00
First Floor Cum 0.00 1.00 0.00
Mezzanine Floor Cum 0.00 1.00 0.00
Second Floor Cum 0.00 1.00 0.00
Third Floor Cum 0.00 1.00 0.00
Fourth Floor Cum 0.00 1.00 0.00
Total Cum 17.54 19.00
2.7 350MM THICK FLY BLOCK MASONRY CODE-A13-01 & 1/A13-08
Basement Floor Cum 0.00 1.00 0.00
Lower Ground Floor Cum 0.00 1.00 0.00
Mezzanine Floor Cum 0.00 1.00 0.00
Ground Floor Cum 0.00 1.00 0.00
First Floor Cum 17.02 1.00 17.02
Mezzanine Floor Cum 0.00 1.00 0.00
Second Floor Cum 0.00 1.00 0.00
Third Floor Cum 0.00 1.00 0.00
Fourth Floor Cum 0.00 1.00 0.00
Total Cum 17.02 18.00
2.8 375MM THICK FLY BLOCK MASONRY CODE-A13-01 & 1/A13-08
Basement Floor Cum 0.00 1.00 0.00
Lower Ground Floor Cum 0.00 1.00 0.00
Mezzanine Floor Cum 0.00 1.00 0.00
Ground Floor Cum 0.00 1.00 0.00
First Floor Cum 0.00 1.00 0.00
Mezzanine Floor Cum 0.00 1.00 0.00
Second Floor Cum 0.00 1.00 0.00
Third Floor Cum 0.00 1.00 0.00
Fourth Floor Cum 0.00 1.00 0.00
Total Cum 0.00 0.00
2.9 400MM THICK FLY BLOCK MASONRY CODE-A13-01 & 1/A13-08
Basement Floor Cum 0.00 1.00 0.00
Lower Ground Floor Cum 0.00 1.00 0.00
Mezzanine Floor Cum 0.00 1.00 0.00
Ground Floor Cum 0.00 1.00 0.00
First Floor Cum 0.00 1.00 0.00
Mezzanine Floor Cum 0.00 1.00 0.00
Second Floor Cum 0.00 1.00 0.00
Third Floor Cum 0.00 1.00 0.00
Fourth Floor Cum 0.00 1.00 0.00
Total Cum 0.00 0.00
2.10 500MM THICK FLY BLOCK MASONRY CODE-A13-01 & 1/A13-08
Basement Floor Cum 0.00 1.00 0.00
Lower Ground Floor Cum 0.00 1.00 0.00
Mezzanine Floor Cum 0.00 1.00 0.00
Ground Floor Cum 0.00 1.00 0.00
First Floor Cum 0.00 1.00 0.00
Mezzanine Floor Cum 0.00 1.00 0.00
Second Floor Cum 0.00 1.00 0.00
Third Floor Cum 0.00 1.00 0.00
Fourth Floor Cum 0.00 1.00 0.00
Total Cum 0.00 0.00
Total of FLYASH Block Cum 490.14 515.00
3 DRY PARTITION
3.1 100 MM THICK DRY PARTITION WITHOUT INSULATION CODE-A13-01 & 2/A13-08
Basement Floor Sqm 0.00 1.00 0.00
Lower Ground Floor Sqm 0.00 1.00 0.00
Mezzanine Floor Sqm 0.00 1.00 0.00
Ground Floor Sqm 0.00 1.00 0.00
First Floor Sqm 0.00 1.00 0.00
Mezzanine Floor Sqm 0.00 1.00 0.00
Second Floor Sqm 171.99 1.00 171.99
Third Floor Sqm 0.00 1.00 0.00
Fourth Floor Sqm 0.00 1.00 0.00
Total Sqm 171.99 181.00
3.2 100 MM THICK DRY PARTITION WITH INSULATION CODE-A13-01 & 3/A13-08
Basement Floor Sqm 0.00 1.00 0.00
Lower Ground Floor Sqm 0.00 1.00 0.00
Mezzanine Floor Sqm 0.00 1.00 0.00
Ground Floor Sqm 0.00 1.00 0.00
First Floor Sqm 0.00 1.00 0.00
Mezzanine Floor Sqm 0.00 1.00 0.00
Second Floor Sqm 0.00 1.00 0.00
Third Floor Sqm 0.00 1.00 0.00
Fourth Floor Sqm 0.00 1.00 0.00
Total Sqm 0.00 0.00
3.3 200 MM THICK DRY PARTITION CODE-A13-01 & 4/A13-08
Basement Floor Sqm 0.00 1.00 0.00
Lower Ground Floor Sqm 0.00 1.00 0.00
Mezzanine Floor Sqm 0.00 1.00 0.00
Ground Floor Sqm 0.00 1.00 0.00
First Floor Sqm 0.00 1.00 0.00
Mezzanine Floor Sqm 0.00 1.00 0.00
Second Floor Sqm 0.00 1.00 0.00
Third Floor Sqm 0.00 1.00 0.00
Fourth Floor Sqm 0.00 1.00 0.00
Total Sqm 0.00 0.00
3.4 300 MM THICK DRY PARTITION (FOR ELIPSE RAMP) CODE-A13-01 & 5/A13-08
Basement Floor Sqm 0.00 1.00 0.00
Lower Ground Floor Sqm 0.00 1.00 0.00
Mezzanine Floor Sqm 0.00 1.00 0.00
Ground Floor Sqm 0.00 1.00 0.00
First Floor Sqm 0.00 1.00 0.00
Mezzanine Floor Sqm 0.00 1.00 0.00
Second Floor Sqm 0.00 1.00 0.00
Third Floor Sqm 0.00 1.00 0.00
Fourth Floor Sqm 0.00 1.00 0.00
Total Sqm 0.00 0.00
4.1 150 MM THICK AAC BLOCK MASONRY CODE-01A13-08
Basement Floor Sqm 0.00 1.00 0.00
Lower Ground Floor Sqm 0.57 1.00 0.57
Mezzanine Floor Sqm 0.00 1.00 0.00
Ground Floor Sqm 0.00 1.00 0.00
First Floor Sqm 0.00 1.00 0.00
Mezzanine Floor Sqm 0.00 1.00 0.00
Second Floor Sqm 0.00 1.00 0.00
Third Floor Sqm 0.00 1.00 0.00
Fourth Floor Sqm 0.00 1.00 0.00
Total Sqm 0.57 1.00
4.2 200 MM THICK AAC BLOCK MASONRY CODE-01A13-08
Basement Floor Sqm 0.00 1.00 0.00
Lower Ground Floor Sqm 0.73 1.00 0.73
Mezzanine Floor Sqm 0.00 1.00 0.00
Ground Floor Sqm 0.00 1.00 0.00
First Floor Sqm 0.00 1.00 0.00
Mezzanine Floor Sqm 0.00 1.00 0.00
Second Floor Sqm 4.33 1.00 4.33
Third Floor Sqm 0.00 1.00 0.00
Fourth Floor Sqm 0.00 1.00 0.00
Total Sqm 5.05 6.00
4.3 250 MM THICK AAC BLOCK MASONRY CODE-01A13-08
Basement Floor Sqm 0.00 1.00 0.00
Lower Ground Floor Sqm 556.51 1.00 556.51
Mezzanine Floor Sqm 173.76 1.00 173.76
Ground Floor Sqm 125.54 1.00 125.54
First Floor Sqm 129.88 1.00 129.88
Mezzanine Floor Sqm 0.00 1.00 0.00
Second Floor Sqm 53.02 1.00 53.02
Third Floor Sqm 0.00 1.00 0.00
Fourth Floor Sqm 0.00 1.00 0.00
Total Sqm 1038.70 1091.00
Total of Fly ash Block Sqm 1044.33 1097.00
3 INTERNAL PLATSER WORK
Basement Floor Sqm 0.00 1.00 0.00
Lower Ground Floor Sqm 7419.60 1.00 7419.60
Mezzanine Floor Sqm 1163.23 1.00 1163.23
Ground Floor Sqm 4392.47 1.00 4392.47
First Floor Sqm 2793.34 1.00 2793.34
Second Floor Sqm 877.47 1.00 877.47
Third Floor Sqm 0.00 1.00 0.00
Fourth Floor Sqm 0.00 1.00 0.00
4 INTERNAL PUTTY WORK
Basement Floor Sqm 0.00 1.00 0.00
Lower Ground Floor Sqm 1115.82 1.00 1115.82
Mezzanine Floor Sqm 355.78 1.00 355.78
Ground Floor Sqm 1767.02 1.00 1767.02
First Floor Sqm 2482.64 1.00 2482.64
Second Floor Sqm 280.04 1.00 280.04
Third Floor Sqm 0.00 1.00 0.00
Fourth Floor Sqm 0.00 1.00 0.00
Total Sqm 6001.31 6302.00
4 CEILING PUTTY WORK
Basement Floor Sqm 0.00 1.00 0.00
Lower Ground Floor Sqm 331.33 1.00 331.33
Mezzanine Floor Sqm 145.91 1.00 145.91
Ground Floor Sqm 276.62 1.00 276.62
First Floor Sqm 281.97 1.00 281.97
Second Floor Sqm 0.00 1.00 0.00
Third Floor Sqm 0.00 1.00 0.00
Fourth Floor Sqm 0.00 1.00 0.00
Total Sqm 1035.83 1088.00
4 TOILET PLASTER
Basement Floor Sqm 0.00 1.00 0.00
Lower Ground Floor Sqm 154.83 1.00 154.83
Mezzanine Floor Sqm 206.10 1.00 206.10
Ground Floor Sqm 965.20 1.00 965.20
First Floor Sqm 448.62 1.00 448.62
Second Floor Sqm 234.95 1.00 234.95
Third Floor Sqm 0.00 1.00 0.00
Fourth Floor Sqm 0.00 1.00 0.00
Total Sqm 2009.70 2111.00
4 EXTERNAL PLASTER
Basement Floor Sqm 0.00 1.00 0.00
Lower Ground Floor Sqm 550.71 1.00 550.71
Mezzanine Floor Sqm 215.00 1.00 215.00
Ground Floor Sqm 1635.53 1.00 1635.53
First Floor Sqm 1516.64 1.00 1516.64
Second Floor Sqm 1708.88 1.00 1708.88
Third Floor Sqm 0.00 1.00 0.00
Fourth Floor Sqm 0.00 1.00 0.00
Total Sqm 5626.75 5909.00
WATERPROOFING COMPOUND
Total Internal Plaster 18694.07
Total External Plaster 5626.75
Considering 2% by weight of Cement bags 2526.48 1.00 2526.48
PLOYESTER FIBRE
Total Internal Plaster 18694.07
Total External Plaster 5626.75
Total Bags of cement 2526.48
125 gms. of synthetic Polyester triangular fibre for 50 Kgs. Cement 315.81 1.00 315.81
Total Kg 315.81 332.00
13 WATERPROOFING WORK
13.1 LOCATION : TOILET
Basement Floor Sqm 0.00 1.00 0.00
Lower Ground Floor Sqm 82.52 1.00 82.52
Mezzanine Floor Sqm 82.52 1.00 82.52
Ground Floor Sqm 321.79 1.00 321.79
First Floor Sqm 152.41 1.00 152.41
Second Floor Sqm 63.99 1.00 63.99
Third Floor Sqm 0.00 1.00 0.00
Fourth Floor Sqm 22.12 1.00 22.12
Total Sqm 725.36 798.00
13.2 LOCATION : BASEMENT ON FLOOR
Basement Floor Sqm 1.00 0.00
Lower Ground Floor Sqm 1.00 0.00
Mezzanine Floor Sqm 1.00 0.00
Ground Floor Sqm 1.00 0.00
First Floor Sqm 1.00 0.00
Second Floor Sqm 1.00 0.00
Third Floor Sqm 1.00 0.00
Fourth Floor Sqm 1.00 0.00
Total Sqm 0.00 0.00
13.3 LOCATION : BASEMENT ON WALL
Basement Floor Sqm 1.00 0.00
Lower Ground Floor Sqm 1.00 0.00
Mezzanine Floor Sqm 1.00 0.00
Ground Floor Sqm 1.00 0.00
First Floor Sqm 1.00 0.00
Second Floor Sqm 1.00 0.00
Third Floor Sqm 1.00 0.00
Fourth Floor Sqm 1.00 0.00
Total Sqm 0.00 0.00
13.4 LOCATION : TERRACE
Basement Floor Sqm 0.00 1.00 0.00
Lower Ground Floor Sqm 0.00 1.00 0.00
Mezzanine Floor Sqm 0.00 1.00 0.00
Ground Floor Sqm 0.00 1.00 0.00
First Floor Sqm 0.00 1.00 0.00
Second Floor Sqm 3130.43 1.00 3130.43
Third Floor Sqm 0.00 1.00 0.00
Fourth Floor Sqm 0.00 1.00 0.00
Total Sqm 3130.43 3444.00
13.5 LOCATION : LIFT PIT (INSIDE)
Basement Floor Sqm 0.00 1.00 0.00
Lower Ground Floor Sqm 59.39 1.00 59.39
Mezzanine Floor Sqm 0.00 1.00 0.00
Ground Floor Sqm 0.00 1.00 0.00
First Floor Sqm 0.00 1.00 0.00
Second Floor Sqm 0.00 1.00 0.00
Third Floor Sqm 0.00 1.00 0.00
Fourth Floor Sqm 0.00 1.00 0.00
Total Sqm 59.39 66.00
13.5 LOCATION : LIFT PIT (OUTSIDE WALL)
Basement Floor Sqm 0.00 1.00 0.00
Lower Ground Floor Sqm 45.73 1.00 45.73
Mezzanine Floor Sqm 0.00 1.00 0.00
Ground Floor Sqm 0.00 1.00 0.00
First Floor Sqm 0.00 1.00 0.00
Second Floor Sqm 0.00 1.00 0.00
Third Floor Sqm 0.00 1.00 0.00
Fourth Floor Sqm 0.00 1.00 0.00
Total Sqm 45.73 51.00
13.5 LOCATION : TANK
Basement Floor Sqm 0.00 1.00 0.00
Lower Ground Floor Sqm 0.00 1.00 0.00
Mezzanine Floor Sqm 0.00 1.00 0.00
Ground Floor Sqm 0.00 1.00 0.00
First Floor Sqm 0.00 1.00 0.00
Second Floor Sqm 116.80 1.00 116.80
Third Floor Sqm 0.00 1.00 0.00
Fourth Floor Sqm 0.00 1.00 0.00
OHT Floor Sqm 0.00 1.00 0.00
Total Sqm 116.80 129.00
Basement Floor Cum 0.00 1.00 0.00
Lower Ground Floor Cum 66.83 1.00 66.83
Mezzanine Floor Cum 152.89 1.00 152.89
Ground Floor Cum 328.86 1.00 328.86
First Floor Cum 99.10 1.00 99.10
Second Floor Cum 42.66 1.00 42.66
Third Floor Cum 0.00 1.00 0.00
Fourth Floor Cum 0.00 1.00 0.00
Total Cum 690.33 760.00
5 FLOORING WORK
5.1 MANDANA-1 (25MM THICK GRANITE) FLOORING CODE-A12-04 & 1/A14-01
Basement Floor Sqm 0.00 1.00 0.00
Lower Ground Floor Sqm 0.00 1.00 0.00
Mezzanine Floor Sqm 0.00 1.00 0.00
Ground Floor Sqm 1207.42 1.00 1207.42
First Floor Sqm 197.70 1.00 197.70
Second Floor Sqm 38.91 1.00 38.91
Third Floor Sqm 0.00 1.00 0.00
Fourth Floor Sqm 0.00 1.00 0.00
Total Sqm 1444.03 1517.00
5.2 T.W WOOD PLANKS 20MM (SOLID WOOD FLOOR) CODE-A12-04 & 5/A14-01
Basement Floor Sqm 0.00 1.00 0.00
Lower Ground Floor Sqm 0.00 1.00 0.00
Mezzanine Floor Sqm 0.00 1.00 0.00
Ground Floor Sqm 159.89 1.00 159.89
First Floor Sqm 0.00 1.00 0.00
Second Floor Sqm 0.00 1.00 0.00
Third Floor Sqm 0.00 1.00 0.00
Fourth Floor Sqm 0.00 1.00 0.00
Total Sqm 159.89 168.00
5.3 VDF CONCERETE FLOORING CODE-A12-04 & 2/A14-02
Basement Floor Sqm 0.00 1.00 0.00
Lower Ground Floor Sqm 0.00 1.00 0.00
Mezzanine Floor Sqm 0.00 1.00 0.00
Ground Floor Sqm 197.61 1.00 197.61
First Floor Sqm 1718.29 1.00 1718.29
Second Floor Sqm 0.00 1.00 0.00
Third Floor Sqm 0.00 1.00 0.00
Fourth Floor Sqm 0.00 1.00 0.00
5.4 25MM THICK SANDSTONE CODE-A12-04 & 1/A14-01
Basement Floor Sqm 0.00 1.00 0.00
Lower Ground Floor Sqm 0.00 1.00 0.00
Mezzanine Floor Sqm 0.00 1.00 0.00
Ground Floor Sqm 0.00 1.00 0.00
First Floor Sqm 0.00 1.00 0.00
Second Floor Sqm 0.00 1.00 0.00
Third Floor Sqm 0.00 1.00 0.00
Fourth Floor Sqm 0.00 1.00 0.00
Total Sqm 0.00 0.00
5.5 25MM THICK STEEL GREY GRANITE FLOORING CODE-A12-04 & 1/A14-01
Basement Floor Sqm 0.00 1.00 0.00
Lower Ground Floor Sqm 0.00 1.00 0.00
Mezzanine Floor Sqm 0.00 1.00 0.00
Ground Floor Sqm 135.32 1.00 135.32
First Floor Sqm 75.22 1.00 75.22
Second Floor Sqm 29.12 1.00 29.12
Third Floor Sqm 0.00 1.00 0.00
Fourth Floor Sqm 0.00 1.00 0.00
Total Sqm 239.65 252.00
5.6 WOODEN DECK CODE-A12-04 & 12/A14-01
Basement Floor Sqm 0.00 1.00 0.00
Lower Ground Floor Sqm 0.00 1.00 0.00
Mezzanine Floor Sqm 0.00 1.00 0.00
Ground Floor Sqm 0.00 1.00 0.00
First Floor Sqm 0.00 1.00 0.00
Second Floor Sqm 23.43 1.00 23.43
Third Floor Sqm 0.00 1.00 0.00
Fourth Floor Sqm 0.00 1.00 0.00
Total Sqm 23.43 25.00
5.7 MANDANA-2 (25MM THICK GRANITE) FLOORING CODE-A12-04 & 1/A14-01
Basement Floor Sqm 0.00 1.00 0.00
Lower Ground Floor Sqm 0.00 1.00 0.00
Mezzanine Floor Sqm 0.00 1.00 0.00
Ground Floor Sqm 272.99 1.00 272.99
First Floor Sqm 0.00 1.00 0.00
Second Floor Sqm 0.00 1.00 0.00
Third Floor Sqm 0.00 1.00 0.00
Fourth Floor Sqm 0.00 1.00 0.00
Total Sqm 272.99 287.00
5.8 RUBBER TILE FLOORING CODE-A12-04 & 3/A14-01
Basement Floor Sqm 0.00 1.00 0.00
Lower Ground Floor Sqm 0.00 1.00 0.00
Mezzanine Floor Sqm 0.00 1.00 0.00
Ground Floor Sqm 9.78 1.00 9.78
First Floor Sqm 0.00 1.00 0.00
Second Floor Sqm 0.00 1.00 0.00
Third Floor Sqm 0.00 1.00 0.00
Fourth Floor Sqm 0.00 1.00 0.00
Total Sqm 9.78 11.00
5.9 S.S WALK OF MATT CODE-A12-04 & 8/A14-01
Basement Floor Sqm 0.00 1.00 0.00
Lower Ground Floor Sqm 1.62 1.00 1.62
Mezzanine Floor Sqm 0.00 1.00 0.00
Ground Floor Sqm 31.05 1.00 31.05
First Floor Sqm 0.00 1.00 0.00
Second Floor Sqm 0.00 1.00 0.00
Third Floor Sqm 0.00 1.00 0.00
Fourth Floor Sqm 0.00 1.00 0.00
Total Sqm 32.67 35.00
6 WALL FINISH WORK
6.1 SANDSTONE CLADDING DRG CODE- A12-05 REF : 6/A14-02
Basement Floor Sqm 0.00 1.00 0.00
Lower Ground Floor Sqm 0.00 1.00 0.00
Mezzanine Floor Sqm 0.00 1.00 0.00
Ground Floor Sqm 595.01 1.00 595.01
First Floor Sqm 171.07 1.00 171.07
Second Floor Sqm 0.00 1.00 0.00
Third Floor Sqm 0.00 1.00 0.00
Fourth Floor Sqm 0.00 1.00 0.00
Total Sqm 766.09 805.00
6.4 MANDANA STONE-3 CLADDING DRG CODE- A12-05 REF : 6/A14-02
Basement Floor Sqm 0.00 1.00 0.00
Lower Ground Floor Sqm 0.00 1.00 0.00
Mezzanine Floor Sqm 0.00 1.00 0.00
Ground Floor Sqm 482.63 1.00 482.63
First Floor Sqm 303.94 1.00 303.94
Second Floor Sqm 0.00 1.00 0.00
Third Floor Sqm 0.00 1.00 0.00
Fourth Floor Sqm 0.00 1.00 0.00
Total Sqm 786.56 826.00
6.5 GRANITE CLADDING DRG CODE- A12-05 REF : 6/A14-02
Basement Floor Sqm 0.00 1.00 0.00
Lower Ground Floor Sqm 56.85 1.00 56.85
Mezzanine Floor Sqm 41.67 1.00 41.67
Ground Floor Sqm 61.51 1.00 61.51
First Floor Sqm 61.51 1.00 61.51
Second Floor Sqm 24.81 1.00 24.81
Third Floor Sqm 0.00 1.00 0.00
Fourth Floor Sqm 0.00 1.00 0.00
Total Sqm 246.36 259.00
Basement Floor Nos. 0.00 1.00 0.00
Lower Ground Floor Nos. 134.76 1.00 134.76
Mezzanine Floor Nos. 98.77 1.00 98.77
Ground Floor Nos. 4456.36 1.00 4456.36
First Floor Nos. 2045.86 1.00 2045.86
Second Floor Nos. 58.81 1.00 58.81
Third Floor Nos. 0.00 1.00 0.00
Fourth Floor Nos. 0.00 1.00 0.00
Total Nos. 6794.56 7475.00
6.2 FIRE RATED GYPSUM BOARD + PAINT DRG CODE- A12-05 REF : 17/A14-02
Basement Floor Sqm 0.00 1.00 0.00
Lower Ground Floor Sqm 0.00 1.00 0.00
Mezzanine Floor Sqm 0.00 1.00 0.00
Ground Floor Sqm 467.39 1.00 467.39
First Floor Sqm 1634.72 1.00 1634.72
Second Floor Sqm 0.00 1.00 0.00
Third Floor Sqm 0.00 1.00 0.00
Fourth Floor Sqm 0.00 1.00 0.00
Total Sqm 2102.10 2208.00
6.3 WOODEN PANELING DRG CODE- A12-05 REF : 7/A14-02
Basement Floor Sqm 0.00 1.00 0.00
Lower Ground Floor Sqm 0.00 1.00 0.00
Mezzanine Floor Sqm 0.00 1.00 0.00
Ground Floor Sqm 459.48 1.00 459.48
First Floor Sqm 78.18 1.00 78.18
Second Floor Sqm 0.00 1.00 0.00
Third Floor Sqm 0.00 1.00 0.00
Fourth Floor Sqm 0.00 1.00 0.00
Total Sqm 537.66 565.00
6.6 S.S CLADDING DRG CODE- A12-05 REF : 13/A14-02
Basement Floor Sqm 0.00 1.00 0.00
Lower Ground Floor Sqm 0.00 1.00 0.00
Mezzanine Floor Sqm 0.00 1.00 0.00
Ground Floor Sqm 0.00 1.00 0.00
First Floor Sqm 0.00 1.00 0.00
Second Floor Sqm 0.00 1.00 0.00
Third Floor Sqm 0.00 1.00 0.00
Fourth Floor Sqm 0.00 1.00 0.00
Total Sqm 0.00 0.00
6.7 VITRIFIED TILES CLADDING DRG CODE- A12-05 REF : 8/A14-02
Basement Floor Sqm 0.00 1.00 0.00
Lower Ground Floor Sqm 0.00 1.00 0.00
Mezzanine Floor Sqm 0.00 1.00 0.00
Ground Floor Sqm 1145.84 1.00 1145.84
First Floor Sqm 233.45 1.00 233.45
Second Floor Sqm 133.41 1.00 133.41
Third Floor Sqm 0.00 1.00 0.00
Fourth Floor Sqm 0.00 1.00 0.00
Total Sqm 1512.69 1589.00
6.8 MIRROR POLISHED GRANITE CLADDING DRG CODE- A12-05 REF : 6/A14-02
Basement Floor Sqm 0.00 1.00 0.00
Lower Ground Floor Sqm 0.00 1.00 0.00
Mezzanine Floor Sqm 0.00 1.00 0.00
Ground Floor Sqm 0.00 1.00 0.00
First Floor Sqm 0.00 1.00 0.00
Second Floor Sqm 0.00 1.00 0.00
Third Floor Sqm 0.00 1.00 0.00
Fourth Floor Sqm 0.00 1.00 0.00
Total Sqm 0.00 0.00
6.9 VENEER CLADDING DRG CODE- A12-05 REF : 16/A14-02
Basement Floor Sqm 0.00 1.00 0.00
Lower Ground Floor Sqm 0.00 1.00 0.00
Mezzanine Floor Sqm 0.00 1.00 0.00
Ground Floor Sqm 45.51 1.00 45.51
First Floor Sqm 0.00 1.00 0.00
Second Floor Sqm 0.00 1.00 0.00
Third Floor Sqm 0.00 1.00 0.00
Fourth Floor Sqm 0.00 1.00 0.00
Total Sqm 45.51 48.00
8 FALSE CEILING WORK
8.1 PUNCHED GYPSUM + ACOUSTIC LINING CODE-A12-07 & 3/A14-04
Basement Floor Sqm 0.00 1.00 0.00
Lower Ground Floor Sqm 380.39 1.00 380.39
Mezzanine Floor Sqm 0.00 1.00 0.00
Ground Floor Sqm 0.00 1.00 0.00
First Floor Sqm 0.00 1.00 0.00
Second Floor Sqm 0.00 1.00 0.00
Third Floor Sqm 0.00 1.00 0.00
Fourth Floor Sqm 0.00 1.00 0.00
Total Sqm 380.39 400.00
8.2 ALUMINUM PANELS CODE-A12-07 & 4/A14-04
Basement Floor Sqm 0.00 1.00 0.00
Lower Ground Floor Sqm 0.00 1.00 0.00
Mezzanine Floor Sqm 0.00 1.00 0.00
Ground Floor Sqm 0.00 1.00 0.00
First Floor Sqm 0.00 1.00 0.00
Second Floor Sqm 0.00 1.00 0.00
Third Floor Sqm 0.00 1.00 0.00
Fourth Floor Sqm 0.00 1.00 0.00
Total Sqm 0.00 0.00
8.3 GYPSUM + ACOUSTIC LINING CODE-A12-07 & 1/A14-04
Basement Floor Sqm 0.00 1.00 0.00
Lower Ground Floor Sqm 0.00 1.00 0.00
Mezzanine Floor Sqm 0.00 1.00 0.00
Ground Floor Sqm 748.42 1.00 748.42
First Floor Sqm 215.96 1.00 215.96
Second Floor Sqm 0.00 1.00 0.00
Third Floor Sqm 0.00 1.00 0.00
Fourth Floor Sqm 0.00 1.00 0.00
Total Sqm 964.38 1013.00
8.4 (AUDI) GYPSUM + ACOUSTIC CODE-A12-07 & 2A/A14-04
Basement Floor Sqm 0.00 1.00 0.00
Lower Ground Floor Sqm 0.00 1.00 0.00
Mezzanine Floor Sqm 0.00 1.00 0.00
Ground Floor Sqm 294.07 1.00 294.07
First Floor Sqm 0.00 1.00 0.00
Second Floor Sqm 0.00 1.00 0.00
Third Floor Sqm 0.00 1.00 0.00
Fourth Floor Sqm 0.00 1.00 0.00
Total Sqm 294.07 309.00
8.5 WOODEN CEILING CODE-A12-07 & 9/A14-04
Basement Floor Sqm 0.00 1.00 0.00
Lower Ground Floor Sqm 0.00 1.00 0.00
Mezzanine Floor Sqm 0.00 1.00 0.00
Ground Floor Sqm 175.59 1.00 175.59
First Floor Sqm 36.00 1.00 36.00
Second Floor Sqm 0.00 1.00 0.00
Third Floor Sqm 0.00 1.00 0.00
Fourth Floor Sqm 0.00 1.00 0.00
Total Sqm 211.59 223.00
8.6 WOODEN SLATS CODE-A12-07 & 10/A14-04
Basement Floor Sqm 0.00 1.00 0.00
Lower Ground Floor Sqm 0.00 1.00 0.00
Mezzanine Floor Sqm 0.00 1.00 0.00
Ground Floor Sqm 94.34 1.00 94.34
First Floor Sqm 0.00 1.00 0.00
Second Floor Sqm 0.00 1.00 0.00
Third Floor Sqm 0.00 1.00 0.00
Fourth Floor Sqm 0.00 1.00 0.00
Total Sqm 94.34 100.00
8.7 FRP CANOPY CODE-A12-07 & 7/A14-04
Basement Floor Sqm 0.00 1.00 0.00
Lower Ground Floor Sqm 0.00 1.00 0.00
Mezzanine Floor Sqm 0.00 1.00 0.00
Ground Floor Sqm 0.00 1.00 0.00
First Floor Sqm 0.00 1.00 0.00
Second Floor Sqm 0.00 1.00 0.00
Third Floor Sqm 0.00 1.00 0.00
Fourth Floor Sqm 0.00 1.00 0.00
Total Sqm 0.00 0.00
8.8 ALUMINIUM GRILL CODE-A12-07 & 22/A14-04
Basement Floor Sqm 0.00 1.00 0.00
Lower Ground Floor Sqm 0.00 1.00 0.00
Mezzanine Floor Sqm 0.00 1.00 0.00
Ground Floor Sqm 0.00 1.00 0.00
First Floor Sqm 0.00 1.00 0.00
Second Floor Sqm 0.00 1.00 0.00
Third Floor Sqm 0.00 1.00 0.00
Fourth Floor Sqm 0.00 1.00 0.00
Total Sqm 0.00 0.00
5 FLOORING WORK
5.1 25MM THICK POLISHED KOTA STONE FLOORING CODE-A12-04 & 4/A14-01
Basement Floor Sqm 0.00 1.00 0.00
Lower Ground Floor Sqm 1950.44 1.00 1950.44
Mezzanine Floor Sqm 329.72 1.00 329.72
Ground Floor Sqm 638.63 1.00 638.63
First Floor Sqm 327.44 1.00 327.44
Second Floor Sqm 34.65 1.00 34.65
Third Floor Sqm 0.00 1.00 0.00
Fourth Floor Sqm 0.00 1.00 0.00
Total Sqm 3280.88 3445.00
5.11 SEALED CONCRETE FLOORING CODE-A12-04 & 13/A14-01
Basement Floor Cum 0.00 1.00 0.00
Lower Ground Floor Cum 159.56 1.00 159.56
Mezzanine Floor Cum 0.00 1.00 0.00
Ground Floor Cum 8.56 1.00 8.56
First Floor Cum 0.00 1.00 0.00
Second Floor Cum 0.00 1.00 0.00
Third Floor Cum 0.00 1.00 0.00
Fourth Floor Cum 0.00 1.00 0.00
Total Cum 0.10 16.81 18.00
5.12 G.I WALK OF MATT CODE-A12-04 & 8/A14-01
Basement Floor Sqm 0.00 1.00 0.00
Lower Ground Floor Sqm 16.20 1.00 16.20
Mezzanine Floor Sqm 0.00 1.00 0.00
Ground Floor Sqm 5.40 1.00 5.40
First Floor Sqm 0.00 1.00 0.00
Second Floor Sqm 9.25 1.00 9.25
Third Floor Sqm 0.00 1.00 0.00
Fourth Floor Sqm 0.00 1.00 0.00
Total Sqm 30.85 33.00
5.13 GRATING CODE-A12-04 & 6/A14-01
Basement Floor Sqm 0.00 1.00 0.00
Lower Ground Floor Sqm 0.00 1.00 0.00
Mezzanine Floor Sqm 3.60 1.00 3.60
Ground Floor Sqm 3.60 1.00 3.60
First Floor Sqm 3.92 1.00 3.92
Second Floor Sqm 3.92 1.00 3.92
Third Floor Sqm 0.00 1.00 0.00
Fourth Floor Sqm 0.00 1.00 0.00
Total Sqm 15.04 16.00
5.14 8MM THICK WHITE GLAZED TILES CODE-A12-04 & 11/A14-01
Basement Floor Sqm 0.00 1.00 0.00
Lower Ground Floor Sqm 0.00 1.00 0.00
Mezzanine Floor Sqm 0.00 1.00 0.00
Ground Floor Sqm 0.00 1.00 0.00
First Floor Sqm 0.00 1.00 0.00
Second Floor Sqm 30.30 1.00 30.30
Third Floor Sqm 0.00 1.00 0.00
Fourth Floor Sqm 0.00 1.00 0.00
Total Sqm 30.30 32.00
5.15 10 MM THICK VITRIFIED TILES FLOORING CODE-A12-04 & 11/A14-01
Basement Floor Sqm 0.00 1.00 0.00
Lower Ground Floor Sqm 54.67 1.00 54.67
Mezzanine Floor Sqm 73.12 1.00 73.12
Ground Floor Sqm 17.97 1.00 17.97
First Floor Sqm 0.00 1.00 0.00
Second Floor Sqm 0.00 1.00 0.00
Third Floor Sqm 0.00 1.00 0.00
Fourth Floor Sqm 0.00 1.00 0.00
Total Sqm 145.75 154.00
5.16 RAISED ANTI-STATIC FLOORING CODE-A12-04 & 9/A14-01
Basement Floor Sqm 0.00 1.00 0.00
Lower Ground Floor Sqm 180.84 1.00 180.84
Mezzanine Floor Sqm 0.00 1.00 0.00
Ground Floor Sqm 0.00 1.00 0.00
First Floor Sqm 0.00 1.00 0.00
Second Floor Sqm 0.00 1.00 0.00
Third Floor Sqm 0.00 1.00 0.00
Fourth Floor Sqm 0.00 1.00 0.00
Total Sqm 180.84 190.00
5.17 CARPET TILE FLOORING CODE-A12-04 & 10/A14-01
Basement Floor Sqm 0.00 1.00 0.00
Lower Ground Floor Sqm 0.00 1.00 0.00
Mezzanine Floor Sqm 0.00 1.00 0.00
Ground Floor Sqm 266.40 1.00 266.40
First Floor Sqm 0.00 1.00 0.00
Second Floor Sqm 382.46 1.00 382.46
Third Floor Sqm 0.00 1.00 0.00
Fourth Floor Sqm 0.00 1.00 0.00
Total Sqm 648.86 682.00
5.18 25 MM THICK GRAY GRANITE FLOORING CODE-A12-04 & 1/A14-01
Basement Floor Sqm 0.00 1.00 0.00
Lower Ground Floor Sqm 61.65 1.00 61.65
Mezzanine Floor Sqm 0.00 1.00 0.00
Ground Floor Sqm 0.00 1.00 0.00
First Floor Sqm 0.00 1.00 0.00
Second Floor Sqm 0.00 1.00 0.00
Third Floor Sqm 0.00 1.00 0.00
Fourth Floor Sqm 0.00 1.00 0.00
Total Sqm 61.65 65.00
5.19 GRANITE+STONE DECK FLOORING CODE-A12-04 & 14/A14-01
Basement Floor Sqm 0.00 1.00 0.00
Lower Ground Floor Sqm 0.00 1.00 0.00
Mezzanine Floor Sqm 0.00 1.00 0.00
Ground Floor Sqm 0.00 1.00 0.00
First Floor Sqm 0.00 1.00 0.00
Second Floor Sqm 25.31 1.00 25.31 show mesurement sheet
Third Floor Sqm 0.00 1.00 0.00
Fourth Floor Sqm 0.00 1.00 0.00
Total Sqm 25.31 27.00
5.20 25MM THICK KOTA STONE FLOORING CODE-A12-04 & 4/A14-01 (LOCATION : Staircase)
Basement Floor Sqm 0.00 1.00 0.00
Lower Ground Floor Sqm 70.44 1.00 70.44
Mezzanine Floor Sqm 91.43 1.00 91.43
Ground Floor Sqm 129.46 1.00 129.46
First Floor Sqm 90.26 1.00 90.26
Second Floor Sqm 21.09 1.00 21.09
Third Floor Sqm 0.00 1.00 0.00
Fourth Floor Sqm 0.00 1.00 0.00
Total Sqm 402.68 423.00
5.21 25MM THICK KOTA STONE-TREADS CODE-A12-04 & 4/A14-01 (LOCATION : Staircase)
Basement Floor Rmt 0.00 1.00 0.00
Lower Ground Floor Rmt 156.00 1.00 156.00
Mezzanine Floor Rmt 58.00 1.00 58.00
Ground Floor Rmt 216.00 1.00 216.00
First Floor Rmt 180.00 1.00 180.00
Second Floor Rmt 0.00 1.00 0.00
Third Floor Rmt 0.00 1.00 0.00
Fourth Floor Rmt 0.00 1.00 0.00
Total Rmt 610.00 641.00
5.22 25MM THICK KOTA STONE-RISERS CODE-A12-04 & 4/A14-01 (LOCATION : Staircase)
Basement Floor Rmt 0.00 1.00 0.00
Lower Ground Floor Rmt 172.00 1.00 172.00
Mezzanine Floor Rmt 64.00 1.00 64.00
Ground Floor Rmt 240.00 1.00 240.00
First Floor Rmt 200.00 1.00 200.00
Second Floor Rmt 0.00 1.00 0.00
Third Floor Rmt 0.00 1.00 0.00
Fourth Floor Rmt 0.00 1.00 0.00
Total Rmt 676.00 710.00
5.23 25MM THICK KOTA STONE-SKIRTING CODE-A12-04 & 4/A14-01 (LOCATION : Staircase)
Basement Floor Rmt 0.00 1.00 0.00
Lower Ground Floor Rmt 67.78 1.00 67.78
Mezzanine Floor Rmt 81.79 1.00 81.79
Ground Floor Rmt 121.02 1.00 121.02
First Floor Rmt 84.14 1.00 84.14
Second Floor Rmt 18.18 1.00 18.18
Third Floor Rmt 0.00 1.00 0.00
Fourth Floor Rmt 0.00 1.00 0.00
Total Rmt 372.91 392.00
Total Sqm 0.10 37.29 40.00
5.24 25MM THICK KOTA STONE-INCLINED SKIRTING CODE-A12-04 & 4/A14-01 (LOCATION : Staircase)
Basement Floor Rmt 0.00 1.00 0.00
Lower Ground Floor Rmt 26.74 1.00 26.74
Mezzanine Floor Rmt 9.94 1.00 9.94
Ground Floor Rmt 37.06 1.00 37.06
First Floor Rmt 30.92 1.00 30.92
Second Floor Rmt 0.00 1.00 0.00
Third Floor Rmt 0.00 1.00 0.00
Fourth Floor Rmt 0.00 1.00 0.00
Total Rmt 104.66 110.00
Total Sqm 0.10 10.47 11.00
6 INTERNAL WALL FINISH WORK
6.10 VITRIFIED TILES-2 CLADDING DRG CODE- A12-05 REF : 8/A14-02
Basement Floor Sqm 0.00 1.00 0.00
Lower Ground Floor Sqm 122.17 1.00 122.17
Mezzanine Floor Sqm 215.63 1.00 215.63
Ground Floor Sqm 264.27 1.00 264.27
First Floor Sqm 0.00 1.00 0.00
Second Floor Sqm 0.00 1.00 0.00
Third Floor Sqm 0.00 1.00 0.00 8996.00
Fourth Floor Sqm 0.00 1.00 0.00
Total Sqm 602.07 633.00
6.11 GYPSUM PLASTER + PAINT DRG CODE- A12-05 REF : 10/A14-02
Basement Floor Sqm 0.00 1.00 0.00
Lower Ground Floor Sqm 3581.77 1.00 3581.77
Mezzanine Floor Sqm 1088.15 1.00 1088.15
Ground Floor Sqm 1332.14 1.00 1332.14
First Floor Sqm 924.55 1.00 924.55
Second Floor Sqm 515.74 1.00 515.74
Third Floor Sqm 0.00 1.00 0.00
Fourth Floor Sqm 0.00 1.00 0.00
Total Sqm 7442.36 7815.00
6.12 GYPSUM PARTITION WALL SYSTEM DRG CODE- A12-05 REF : 9/A14-02 (100 MM THICK DRY WALL PARTITION)
Basement Floor Sqm 0.00 1.00 0.00
Lower Ground Floor Sqm 0.00 1.00 0.00
Mezzanine Floor Sqm 0.00 1.00 0.00
Ground Floor Sqm 0.00 1.00 0.00
First Floor Sqm 0.00 1.00 0.00
Second Floor Sqm 179.88 1.00 179.88
Third Floor Sqm 0.00 1.00 0.00
Fourth Floor Sqm 0.00 1.00 0.00
Total Sqm 179.88 189.00
6.13 SOUND ATTENAUTION DRG CODE- A12-05 REF : 11/A14-02
Basement Floor Sqm 0.00 1.00 0.00
Lower Ground Floor Sqm 602.27 1.00 602.27
Mezzanine Floor Sqm 221.42 1.00 221.42
Ground Floor Sqm 210.88 1.00 210.88
First Floor Sqm 533.06 1.00 533.06
Second Floor Sqm 74.70 1.00 74.70
Third Floor Sqm 0.00 1.00 0.00
Fourth Floor Sqm 0.00 1.00 0.00
Total Sqm 1642.33 1725.00
6.14 WHITE GLAZED VITRIFIED TILES CLADDING DRG CODE- A12-05 REF : 8/A14-02
Basement Floor Sqm 0.00 1.00 0.00
Lower Ground Floor Sqm 0.00 1.00 0.00
Mezzanine Floor Sqm 28.50 1.00 28.50
Ground Floor Sqm 0.00 1.00 0.00
First Floor Sqm 0.00 1.00 0.00
Second Floor Sqm 86.50 1.00 86.50
Third Floor Sqm 0.00 1.00 0.00
Fourth Floor Sqm 0.00 1.00 0.00
Total Sqm 114.99 121.00
6.15 PLASTER + PAINT DRG CODE- A12-05 REF : 14/A14-02
Basement Floor Sqm 0.00 1.00 0.00
Lower Ground Floor Sqm 412.99 1.00 412.99
Mezzanine Floor Sqm 0.00 1.00 0.00
Ground Floor Sqm 0.00 1.00 0.00
First Floor Sqm 0.00 1.00 0.00
Second Floor Sqm 0.00 1.00 0.00
Third Floor Sqm 0.00 1.00 0.00
Fourth Floor Sqm 0.00 1.00 0.00
Total Sqm 412.99 434.00
6.16 PLASTER FINISH DRG CODE- A12-05 REF : 15/A14-02
Basement Floor Sqm 0.00 1.00 0.00
Lower Ground Floor Sqm 377.90 1.00 377.90
Mezzanine Floor Sqm 291.40 1.00 291.40
Ground Floor Sqm 619.07 1.00 619.07
First Floor Sqm 747.53 1.00 747.53
Second Floor Sqm 205.00 1.00 205.00
Third Floor Sqm 0.00 1.00 0.00
Fourth Floor Sqm 0.00 1.00 0.00
Total Sqm 2240.91 2353.00
6.17 ALUMINIUM CLADDING DRG CODE- A12-05 REF : 12/A14-02
Basement Floor Sqm 0.00 1.00 0.00
Lower Ground Floor Sqm 0.00 1.00 0.00
Mezzanine Floor Sqm 0.00 1.00 0.00
Ground Floor Sqm 0.00 1.00 0.00
First Floor Sqm 0.00 1.00 0.00
Second Floor Sqm 0.00 1.00 0.00
Third Floor Sqm 0.00 1.00 0.00
Fourth Floor Sqm 0.00 1.00 0.00
Total Sqm 0.00 0.00
7 SKIRTING WORK
7.1 WOODEN SKIRTING CODE-A12-06 & 3/A14-03
Basement Floor Rmt 0.00 1.00 0.00
Lower Ground Floor Rmt 0.00 1.00 0.00
Mezzanine Floor Rmt 0.00 1.00 0.00
Ground Floor Rmt 142.31 1.00 142.31
First Floor Rmt 143.85 1.00 143.85
Second Floor Rmt 72.74 1.00 72.74
Third Floor Rmt 0.00 1.00 0.00
Fourth Floor Rmt 0.00 1.00 0.00
Total Rmt 358.90 377.00
7.2 KOTA STONE SKIRTING (LOADING BAY) CODE-A12-06 & 2/A14-03
Basement Floor Sqm 3.27 1.00 3.27
Lower Ground Floor Sqm 0.00 1.00 0.00
Mezzanine Floor Sqm 0.00 1.00 0.00
Ground Floor Sqm 0.00 1.00 0.00
First Floor Sqm 0.00 1.00 0.00
Second Floor Sqm 0.00 1.00 0.00
Third Floor Sqm 0.00 1.00 0.00
Fourth Floor Sqm 0.00 1.00 0.00
Total Sqm 3.27 4.00
7.3 KOTA STONE SKIRTING CODE-A12-06 & 1/A14-03
Basement Floor Sqm 0.00 1.00 0.00
Lower Ground Floor Sqm 111.20 1.00 111.20
Mezzanine Floor Sqm 22.03 1.00 22.03
Ground Floor Sqm 43.42 1.00 43.42
First Floor Sqm 18.23 1.00 18.23
Second Floor Sqm 4.24 1.00 4.24
Third Floor Sqm 0.00 1.00 0.00
Fourth Floor Sqm 0.00 1.00 0.00
Total Sqm 199.11 210.00
7.4 S.S BASE (COLUMN) CODE-A12-06 & 4/A14-03
Basement Floor Sqm 0.00 1.00 0.00
Lower Ground Floor Sqm 0.00 1.00 0.00
Mezzanine Floor Sqm 0.00 1.00 0.00
Ground Floor Sqm 10.84 1.00 10.84
First Floor Sqm 0.00 1.00 0.00
Second Floor Sqm 0.00 1.00 0.00
Third Floor Sqm 0.00 1.00 0.00
Fourth Floor Sqm 0.00 1.00 0.00
Total Sqm 10.84 12.00
8 FALSE CEILING WORK (BOH)
8.9 MINERAL FIBRE GRID CEILING 600X600 CODE-A12-07 & 2/A14-04
Basement Floor Sqm 0.00 1.00 0.00
Lower Ground Floor Sqm 1302.86 1.00 1302.86
Mezzanine Floor Sqm 170.91 1.00 170.91
Ground Floor Sqm 331.35 1.00 331.35
First Floor Sqm 216.26 1.00 216.26
Second Floor Sqm 182.19 1.00 182.19
Third Floor Sqm 0.00 1.00 0.00
Fourth Floor Sqm 0.00 1.00 0.00
Total Sqm 2203.57 2314.00
8.10 GYPSUM + PAINT CODE-A12-07 & 5/A14-04
Basement Floor Sqm 0.00 1.00 0.00
Lower Ground Floor Sqm 0.00 1.00 0.00
Mezzanine Floor Sqm 0.00 1.00 0.00
Ground Floor Sqm 151.55 1.00 151.55
First Floor Sqm 70.78 1.00 70.78
Second Floor Sqm 294.01 1.00 294.01
Third Floor Sqm 0.00 1.00 0.00
Fourth Floor Sqm 0.00 1.00 0.00
Total Sqm 516.34 543.00
8.11 PLASTER FINISH CODE-A12-07
Basement Floor Sqm 0.00 1.00 0.00
Lower Ground Floor Sqm 0.00 1.00 0.00
Mezzanine Floor Sqm 0.00 1.00 0.00
Ground Floor Sqm 0.00 1.00 0.00
First Floor Sqm 8.38 1.00 8.38
Second Floor Sqm 29.87 1.00 29.87
Third Floor Sqm 0.00 1.00 0.00
Fourth Floor Sqm 0.00 1.00 0.00
Total Sqm 38.25 41.00
8.12 METAL CEILING CODE-A12-07 & 11/A14-04
Basement Floor Sqm 0.00 1.00 0.00
Lower Ground Floor Sqm 0.00 1.00 0.00
Mezzanine Floor Sqm 0.00 1.00 0.00
Ground Floor Sqm 200.97 1.00 200.97
First Floor Sqm 0.00 1.00 0.00
Second Floor Sqm 6.56 1.00 6.56
Third Floor Sqm 0.00 1.00 0.00
Fourth Floor Sqm 0.00 1.00 0.00
Total Sqm 207.53 218.00
8.13 PLASTER + PAINT CODE-A12-07 & 5/A14-04
Basement Floor Sqm 37.88 1.00 37.88
Lower Ground Floor Sqm 155.47 1.00 155.47
Mezzanine Floor Sqm 0.00 1.00 0.00
Ground Floor Sqm 0.00 1.00 0.00
First Floor Sqm 0.00 1.00 0.00
Second Floor Sqm 0.00 1.00 0.00
Third Floor Sqm 0.00 1.00 0.00
Fourth Floor Sqm 0.00 1.00 0.00
Total Sqm 193.35 204.00
8.14 SOUND ATTENUATION CODE-A12-07 & 8/A14-04
Basement Floor Sqm 0.00 1.00 0.00
Lower Ground Floor Sqm 302.96 1.00 302.96
Mezzanine Floor Sqm 156.67 1.00 156.67
Ground Floor Sqm 83.75 1.00 83.75
First Floor Sqm 103.66 1.00 103.66
Second Floor Sqm 19.18 1.00 19.18
Third Floor Sqm 0.00 1.00 0.00
Fourth Floor Sqm 0.00 1.00 0.00
Total Sqm 666.22 700.00
8.15 M.R GRADE GYPSUM GRID 600X600 CODE-A12-07 & 7/A14-04
Basement Floor Sqm 0.00 1.00 0.00
Lower Ground Floor Sqm 53.34 1.00 53.34
Mezzanine Floor Sqm 72.22 1.00 72.22
Ground Floor Sqm 31.50 1.00 31.50
First Floor Sqm 0.00 1.00 0.00
Second Floor Sqm 0.00 1.00 0.00
Third Floor Sqm 0.00 1.00 0.00
Fourth Floor Sqm 0.00 1.00 0.00
Total Sqm 157.06 165.00
8.16 BARRIOL CEILING CODE-A12-07 & 20/A14-04
Basement Floor Sqm 1.00 0.00
Lower Ground Floor Sqm 1.00 0.00
Mezzanine Floor Sqm 1.00 0.00
Ground Floor Sqm 1.00 0.00
First Floor Sqm 1.00 0.00
Second Floor Sqm 1.00 0.00
Third Floor Sqm 1.00 0.00
Fourth Floor Sqm 1.00 0.00
Total Sqm 0.00 0.00
14.1 300 MM HIGH GUARD RAIL CODE-A12-12 & 03/A7-22
Basement Floor Rmt 0.00 1.00 0.00
Lower Ground Floor Rmt 0.00 1.00 0.00
Mezzanine Floor Rmt 0.00 1.00 0.00
Ground Floor Rmt 16.20 1.00 16.20
First Floor Rmt 0.00 1.00 0.00
Second Floor Rmt 0.00 1.00 0.00
Third Floor Rmt 0.00 1.00 0.00
Fourth Floor Rmt 0.00 1.00 0.00
Total Rmt 16.20 18.00
14.2 800 MM HIGH DOUBLE HANDLE WOODEN RAIL CODE-A12-12 & 06/A7-22
Basement Floor Rmt 0.00 1.00 0.00
Lower Ground Floor Rmt 0.00 1.00 0.00
Mezzanine Floor Rmt 0.00 1.00 0.00
Ground Floor Rmt 0.00 1.00 0.00
First Floor Rmt 0.00 1.00 0.00
Second Floor Rmt 0.00 1.00 0.00
Third Floor Rmt 0.00 1.00 0.00
Fourth Floor Rmt 0.00 1.00 0.00
Total Rmt 0.00 0.00
14.3 900MM HIGH WALL MOUNTED S.S RAIL CODE-A12-12 & 01/A7-22
Basement Floor Rmt 0.00 1.00 0.00
Lower Ground Floor Rmt 155.34 1.00 155.34
Mezzanine Floor Rmt 101.66 1.00 101.66
Ground Floor Rmt 207.85 1.00 207.85
First Floor Rmt 145.98 1.00 145.98
Second Floor Rmt 18.18 1.00 18.18
Third Floor Rmt 0.00 1.00 0.00
Fourth Floor Rmt 0.00 1.00 0.00
Total Rmt 629.01 661.00
14.4 900 MM HIGH WALL MOUNTED WOODEN RAIL CODE-A12-12 & 02/A7-22
Basement Floor Rmt 0.00 1.00 0.00
Lower Ground Floor Rmt 0.00 1.00 0.00
Mezanine Floor Rmt 0.00 1.00 0.00
Ground Floor Rmt 0.00 1.00 0.00
First Floor Rmt 0.00 1.00 0.00
Second Floor Rmt 0.00 1.00 0.00
Third Floor Rmt 0.00 1.00 0.00
Fourth Floor Rmt 0.00 1.00 0.00
Total Rmt 0.00 0.00
14.5 1100 MM HIGH GLASS WITH WOODEN RAIL CODE-A12-12 & 09/A7-22
Basement Floor Rmt 0.00 1.00 0.00
Lower Ground Floor Rmt 0.00 1.00 0.00
Mezzanine Floor Rmt 0.00 1.00 0.00
Ground Floor Rmt 0.00 1.00 0.00
First Floor Rmt 11.31 1.00 11.31
Second Floor Rmt 0.00 1.00 0.00
Third Floor Rmt 0.00 1.00 0.00
Fourth Floor Rmt 0.00 1.00 0.00
Total Rmt 11.31 12.00
14.6 1100 MM HIGH GLASS WITH WOODEN TOP RAIL CODE-A12-12 & 09/A7-22
Basement Floor Rmt 0.00 1.00 0.00
Lower Ground Floor Rmt 0.00 1.00 0.00
Mezzanine Floor Rmt 0.00 1.00 0.00
Ground Floor Rmt 0.00 1.00 0.00
First Floor Rmt 0.00 1.00 0.00
Second Floor Rmt 0.00 1.00 0.00
Third Floor Rmt 0.00 1.00 0.00
Fourth Floor Rmt 0.00 1.00 0.00
Total Rmt 0.00 0.00
14.7 900 MM HIGH G.I RAILING CODE-A12-12 & 07/A7-22
Basement Floor Rmt 0.00 1.00 0.00
Lower Ground Floor Rmt 3.00 1.00 3.00
Mezzanine Floor Rmt 0.00 1.00 0.00
Ground Floor Rmt 3.00 1.00 3.00
First Floor Rmt 0.00 1.00 0.00
Second Floor Rmt 0.00 1.00 0.00
Third Floor Rmt 0.00 1.00 0.00
Fourth Floor Rmt 0.00 1.00 0.00
Total Rmt 6.00 7.00
14.8 900 MM HIGH WOODEN RAIL CODE-A12-12 & 10/A7-22
Basement Floor Rmt 0.00 1.00 0.00
Lower Ground Floor Rmt 0.00 1.00 0.00
Mezzanine Floor Rmt 0.00 1.00 0.00
Ground Floor Rmt 0.00 1.00 0.00
First Floor Rmt 0.00 1.00 0.00
Second Floor Rmt 0.00 1.00 0.00
Third Floor Rmt 0.00 1.00 0.00
Fourth Floor Rmt 0.00 1.00 0.00
Total Rmt 0.00 0.00
14.9 600 MM GLASS WITH SS CAP CODE-A12-12 & 08/A7-22
Basement Floor Rmt 0.00 1.00 0.00
Lower Ground Floor Rmt 0.00 1.00 0.00
Mezzanine Floor Rmt 0.00 1.00 0.00
Ground Floor Rmt 0.00 1.00 0.00
First Floor Rmt 0.00 1.00 0.00
Second Floor Rmt 0.00 1.00 0.00
Third Floor Rmt 0.00 1.00 0.00
Fourth Floor Rmt 0.00 1.00 0.00
Total Rmt 0.00 0.00
14.10 GRANITE COUNTER
Basement Floor Sqm 0.00 1.00 0.00
Lower Ground floor Sqm 5.15 1.00 5.15
Mezzanine Floor Sqm 4.88 1.00 4.88
Ground Floor Sqm 4.92 1.00 4.92
First Floor Sqm 2.15 1.00 2.15
Second floor Sqm 0.00 1.00 0.00
Third floor Sqm 0.00 1.00 0.00
Fourth Floor Sqm 0.00 1.00 0.00
Total Sqm 17.09 18.00
14.12 FACIA - GRANITE
Basement Floor Rmt 0.00 1.00 0.00
Lower Ground Floor Rmt 7.20 1.00 7.20
Mezzanine Floor Rmt 7.50 1.00 7.50
Ground Floor Rmt 7.80 1.00 7.80
First Floor Rmt 3.30 1.00 3.30
Second Floor Rmt 0.00 1.00 0.00
Third Floor Rmt 0.00 1.00 0.00
Fourth Floor Rmt 0.00 1.00 0.00
Total Rmt 25.80 28.00
14.13 SINK NUMBER
Basement Floor Nos 0.00 1.00 0.00
Lower Ground Floor Nos 7.00 1.00 7.00
Mezzanine Floor Nos 6.00 1.00 6.00
Ground Floor Nos 7.00 1.00 7.00
First Floor Nos 3.00 1.00 3.00
Second Floor Nos 0.00 1.00 0.00
Third Floor Nos 0.00 1.00 0.00
Fourth Floor Nos 0.00 1.00 0.00
Total Nos 23.00 23.00
1 CUBICLES-L shape
Basement Floor Nos 0.00 1.00 0.00
Lower Ground Floor Nos 4.00 1.00 4.00
Mezzanine Floor Nos 4.00 1.00 4.00
Ground Floor Nos 18.00 1.00 18.00
First Floor Nos 10.00 1.00 10.00
Second Floor Nos 2.00 1.00 2.00
Third Floor Nos 0.00 1.00 0.00
Fourth Floor Nos 0.00 1.00 0.00
Total Nos 38.00 38.00
1 CUBICLES-I shape
Basement Floor Nos 0.00 1.00 0.00
Lower Ground Floor Nos 5.00 1.00 5.00
Mezzanine Floor Nos 5.00 1.00 5.00
Ground Floor Nos 5.00 1.00 5.00
First Floor Nos 2.00 1.00 2.00
Second Floor Nos 2.00 1.00 2.00
Third Floor Nos 0.00 1.00 0.00
Fourth Floor Nos 0.00 1.00 0.00
Total Nos 19.00 19.00
2 URINAL PARTITION
Basement Floor Sqm 0.00 1.00 0.00
Lower Ground Floor Sqm 0.60 1.00 0.60
Mezzanine Floor Sqm 0.60 1.00 0.60
Ground Floor Sqm 2.40 1.00 2.40
First Floor Sqm 1.20 1.00 1.20
Second Floor Sqm 0.90 1.00 0.90
Third Floor Sqm 0.00 1.00 0.00
Fourth Floor Sqm 0.00 1.00 0.00
Total Sqm 5.70 6.00
9 PARAPET FINISH
9.1 2 SIDE PLASTER CODE-A12-08 & 4/A11-01
Basement Floor Sqm 0.00 1.00 0.00
Lower Ground Floor Sqm 0.00 1.00 0.00
Mezzanine Floor Sqm 0.00 1.00 0.00
Ground Floor Sqm 0.00 1.00 0.00
First Floor Sqm 0.00 1.00 0.00
Second Floor Sqm 0.00 1.00 0.00
Third Floor Sqm 0.00 1.00 0.00
Fourth Floor Sqm 178.75 1.00 178.75
Total Sqm 178.75 188.00
9.2 1SIDE STONE CLADDING CODE-A12-08 & 1/A11-01
Basement Floor Sqm 0.00 1.00 0.00
Lower Ground Floor Sqm 0.00 1.00 0.00
Mezzanine Floor Sqm 0.00 1.00 0.00
Ground Floor Sqm 0.00 1.00 0.00
First Floor Sqm 19.67 1.00 19.67
Second Floor Sqm 0.00 1.00 0.00
Third Floor Sqm 0.00 1.00 0.00
Fourth Floor Sqm 0.00 1.00 0.00
Roof Floor Sqm 213.06 1.00 213.06
Total Sqm 232.73 245.00
9.3 EXTENDED CLADDING CODE-A12-08 & 2/A11-01
Basement Floor Sqm 0.00 1.00 0.00
Lower Ground Floor Sqm 0.00 1.00 0.00
Mezzanine Floor Sqm 0.00 1.00 0.00
Ground Floor Sqm 0.00 1.00 0.00
First Floor Sqm 0.00 1.00 0.00
Second Floor Sqm 0.00 1.00 0.00
Third Floor Sqm 0.00 1.00 0.00
Fourth Floor Sqm 0.00 1.00 0.00
Roof Floor Sqm 10.54 1.00 10.54
Total Sqm 10.54 12.00
9.4 2 SIDE STONE CLADDING CODE-A12-08 & 3/A11-01
Basement Floor Sqm 0.00 1.00 0.00
Lower Ground Floor Sqm 0.00 1.00 0.00
Mezzanine Floor Sqm 0.00 1.00 0.00
Ground Floor Sqm 0.00 1.00 0.00
First Floor Sqm 0.00 1.00 0.00
Second Floor Sqm 0.00 1.00 0.00
Third Floor Sqm 0.00 1.00 0.00
Fourth Floor Sqm 0.00 1.00 0.00
Roof Floor Sqm 24.56 1.00 24.56
Total Sqm 24.56 26.00
9.5 S.S CLADDING CODE-A12-08 & 5/A11-01
Basement Floor Sqm 0.00 1.00 0.00
Lower Ground Floor Sqm 0.00 1.00 0.00
Mezzanine Floor Sqm 0.00 1.00 0.00
Ground Floor Sqm 0.00 1.00 0.00
First Floor Sqm 0.00 1.00 0.00
Second Floor Sqm 0.00 1.00 0.00
Third Floor Sqm 0.00 1.00 0.00
Fourth Floor Sqm 0.00 1.00 0.00
Roof Floor Sqm 17.15 1.00 17.15
Total Sqm 17.15 19.00
9.6 WET CLADDING CODE-A12-08 & 6/A11-01
Basement Floor Sqm 1.00 0.00
Lower Ground Floor Sqm 1.00 0.00
Mezzanine Floor Sqm 1.00 0.00
Ground Floor Sqm 1.00 0.00
First Floor Sqm 1.00 0.00
Second Floor Sqm 1.00 0.00
Third Floor Sqm 1.00 0.00
Fourth Floor Sqm 1.00 0.00
Total Sqm 0.00 0.00
10 FLASHING TYPE
10.1 FLASHING TYPE 1 CODE-A12-08 & 5/A11-01
Basement Floor Sqm 0.00 1.00 0.00
Lower Ground Floor Sqm 0.00 1.00 0.00
Mezzanine Floor Sqm 0.00 1.00 0.00
Ground Floor Sqm 0.00 1.00 0.00
First Floor Sqm 15.30 1.00 15.30
Second Floor Sqm 0.00 1.00 0.00
Third Floor Sqm 0.00 1.00 0.00
Fourth Floor Sqm 0.00 1.00 0.00
Roof Floor Sqm 104.32 1.00 104.32
Total Sqm 119.61 126.00
10.2 FLASHING TYPE 2 CODE-A12-08 & 6/A11-01
Basement Floor Sqm 0.00 1.00 0.00
Lower Ground Floor Sqm 0.00 1.00 0.00
Mezzanine Floor Sqm 0.00 1.00 0.00
Ground Floor Sqm 0.00 1.00 0.00
First Floor Sqm 0.00 1.00 0.00
Second Floor Sqm 0.00 1.00 0.00
Third Floor Sqm 0.00 1.00 0.00
Fourth Floor Sqm 0.00 1.00 0.00
Roof Floor Sqm 6.40 1.00 6.40
Total Sqm 6.40 7.00
10.3 FLASHING TYPE 3 CODE-A12-08 & 7/A11-01
Basement Floor Sqm 0.00 1.00 0.00
Lower Ground Floor Sqm 0.00 1.00 0.00
Mezzanine Floor Sqm 0.00 1.00 0.00
Ground Floor Sqm 0.00 1.00 0.00
First Floor Sqm 0.00 1.00 0.00
Second Floor Sqm 0.00 1.00 0.00
Third Floor Sqm 0.00 1.00 0.00
Fourth Floor Sqm 0.00 1.00 0.00
Roof Floor Sqm 354.90 1.00 354.90
Total Sqm 354.90 373.00
10.4 FLASHING TYPE 4 CODE-A12-08 & 7A/A11-01
Basement Floor Sqm 0.00 1.00 0.00
Lower Ground Floor Sqm 0.00 1.00 0.00
Mezzanine Floor Sqm 0.00 1.00 0.00
Ground Floor Sqm 0.00 1.00 0.00
First Floor Sqm 0.00 1.00 0.00
Second Floor Sqm 0.00 1.00 0.00
Third Floor Sqm 0.00 1.00 0.00
Fourth Floor Sqm 0.00 1.00 0.00
Roof Floor Sqm 40.20 1.00 40.20
Total Sqm 40.20 43.00
11 ROOF LEVEL FINISH
11.1 LOOSE GRAVEL STONE CODE-A12-09 & 15/A14-01
Basement Floor Sqm 0.00 1.00 0.00
Lower Ground Floor Sqm 0.00 1.00 0.00
Mezzanine Floor Sqm 0.00 1.00 0.00
Ground Floor Sqm 0.00 1.00 0.00
First Floor Sqm 0.00 1.00 0.00
Second Floor Sqm 0.00 1.00 0.00
Third Floor Sqm 0.00 1.00 0.00
Fourth Floor Sqm 0.00 1.00 0.00
Roof Floor Sqm 2445.72 1.00 2445.72
Total Sqm 2445.72 2569.00
11.2 GREEN ROOF CODE-A12-09 & 15/A14-01
Basement Floor Sqm 0.00 1.00 0.00
Lower Ground Floor Sqm 0.00 1.00 0.00
Mezzanine Floor Sqm 0.00 1.00 0.00
Ground Floor Sqm 0.00 1.00 0.00
First Floor Sqm 0.00 1.00 0.00
Second Floor Sqm 0.00 1.00 0.00
Third Floor Sqm 0.00 1.00 0.00
Fourth Floor Sqm 0.00 1.00 0.00
Roof Floor Sqm 552.03 1.00 552.03
Total Sqm 552.03 580.00
11.3 WOODEN DECKING CODE-A12-09 & 15/A14-01
Basement Floor Sqm 0.00 1.00 0.00
Lower Ground Floor Sqm 0.00 1.00 0.00
Mezzanine Floor Sqm 0.00 1.00 0.00
Ground Floor Sqm 0.00 1.00 0.00
First Floor Sqm 0.00 1.00 0.00
Second Floor Sqm 0.00 1.00 0.00
Third Floor Sqm 0.00 1.00 0.00
Fourth Floor Sqm 0.00 1.00 0.00
Total Sqm 0.00 0.00
11.4 ZINC ROOFING CODE-A12-09 & 15/A14-01
Basement Floor Sqm 0.00 1.00 0.00
Lower Ground Floor Sqm 0.00 1.00 0.00
Mezzanine Floor Sqm 0.00 1.00 0.00
Ground Floor Sqm 0.00 1.00 0.00
First Floor Sqm 0.00 1.00 0.00
Second Floor Sqm 0.00 1.00 0.00
Third Floor Sqm 0.00 1.00 0.00
Fourth Floor Sqm 0.00 1.00 0.00
Roof Floor Sqm 1534.83 1.00 1534.83
Total Sqm 1534.83 1612.00
11.5 KOTA STONE CODE-A12-09 & 4/A14-01
Basement Floor Sqm 0.00 1.00 0.00
Lower Ground Floor Sqm 0.00 1.00 0.00
Mezzanine Floor Sqm 0.00 1.00 0.00
Ground Floor Sqm 0.00 1.00 0.00
First Floor Sqm 0.00 1.00 0.00
Second Floor Sqm 0.00 1.00 0.00
Third Floor Sqm 0.00 1.00 0.00
Fourth Floor Sqm 0.00 1.00 0.00
Total Sqm 0.00 0.00
Basement Floor Sqm 0.00 1.00 0.00
Lower Ground Floor Sqm 0.00 1.00 0.00
Mezzanine Floor Sqm 0.00 1.00 0.00
Ground Floor Sqm 0.00 1.00 0.00
First Floor Sqm 0.00 1.00 0.00
Second Floor Sqm 0.00 1.00 0.00
Third Floor Sqm 0.00 1.00 0.00
Fourth Floor Sqm 0.00 1.00 0.00
Total Sqm 0.00 0.00
12 DRAINAGE WALL FINISH
12.1 STONE WALL-LAWN DRAIN CODE-A12-11 & 1/A11-02
Basement Floor Rmt 0.00 1.00 0.00
Lower Ground Floor Rmt 12.81 1.00 12.81
Mezzanine Floor Rmt 0.00 1.00 0.00
Ground Floor Rmt 0.00 1.00 0.00
First Floor Rmt 0.00 1.00 0.00
Second Floor Rmt 0.00 1.00 0.00
Third Floor Rmt 0.00 1.00 0.00
Fourth Floor Rmt 0.00 1.00 0.00
Total Rmt 12.81 14.00
12.2 STONE WALL-STONE FLOOR DRAIN CODE-A12-11 & 2/A11-02
Basement Floor Rmt 0.00 1.00 0.00
Lower Ground Floor Rmt 44.19 1.00 44.19
Mezzanine Floor Rmt 0.00 1.00 0.00
Ground Floor Rmt 174.10 1.00 174.10
First Floor Rmt 0.00 1.00 0.00
Second Floor Rmt 0.00 1.00 0.00
Third Floor Rmt 0.00 1.00 0.00
Fourth Floor Rmt 0.00 1.00 0.00
Total Rmt 218.30 230.00
12.3 ALUM. GLAZING - STONE FLOOR DRAIN CODE-A12-11 & 3/A11-02
Basement Floor Rmt 0.00 1.00 0.00
Lower Ground Floor Rmt 14.40 1.00 14.40
Mezzanine Floor Rmt 0.00 1.00 0.00
Ground Floor Rmt 16.20 1.00 16.20
First Floor Rmt 0.00 1.00 0.00
Second Floor Rmt 0.00 1.00 0.00
Third Floor Rmt 0.00 1.00 0.00
Fourth Floor Rmt 0.00 1.00 0.00
Total Rmt 30.60 33.00
12.4 STONE WALL - STONE FLOOR (WITHOUT PEBBLE) DRAIN CODE-A12-11 & 4/A11-02
Basement Floor Rmt 0.00 1.00 0.00
Lower Ground Floor Rmt 581.94 1.00 581.94
Mezzanine Floor Rmt 0.00 1.00 0.00
Ground Floor Rmt 0.00 1.00 0.00
First Floor Rmt 0.00 1.00 0.00
Second Floor Rmt 0.00 1.00 0.00
Third Floor Rmt 0.00 1.00 0.00
Fourth Floor Rmt 0.00 1.00 0.00
Total Rmt 581.94 612.00
12.5 STONE FLOOR - STONE FLOOR DRAIN CODE-A12-11 & 5/A11-02
Basement Floor Rmt 0.00 1.00 0.00
Lower Ground Floor Rmt 4.80 1.00 4.80
Mezzanine Floor Rmt 0.00 1.00 0.00
Ground Floor Rmt 56.42 1.00 56.42
First Floor Rmt 0.00 1.00 0.00
Second Floor Rmt 0.00 1.00 0.00
Third Floor Rmt 0.00 1.00 0.00
Fourth Floor Rmt 0.00 1.00 0.00
Total Rmt 61.22 65.00
12.6 STONE FLOOR - ROAD DRAIN (HEAVY DUTY) CODE-A12-11 & 6/A11-02
Basement Floor Rmt 0.00 1.00 0.00
Lower Ground Floor Rmt 6.60 1.00 6.60
Mezzanine Floor Rmt 0.00 1.00 0.00
Ground Floor Rmt 0.00 1.00 0.00
First Floor Rmt 0.00 1.00 0.00
Second Floor Rmt 0.00 1.00 0.00
Third Floor Rmt 0.00 1.00 0.00
Fourth Floor Rmt 0.00 1.00 0.00
Total Rmt 6.60 7.00
12.7 STONE WALL - ROAD DRAIN CODE-A12-11 & 7/A11-02
Basement Floor Sqm 0.00 1.00 0.00
Lower Ground Floor Sqm 0.00 1.00 0.00
Mezzanine Floor Sqm 0.00 1.00 0.00
Ground Floor Sqm 0.00 1.00 0.00
First Floor Sqm 0.00 1.00 0.00
Second Floor Sqm 0.00 1.00 0.00
Third Floor Sqm 0.00 1.00 0.00
Fourth Floor Sqm 0.00 1.00 0.00
Total Sqm 0.00 0.00
13 WATERPROOFING BELOW GROUND LEVEL
13.1 1.2 mm HDPE MEMBRANE PRESSURE SENSITIVE ADHESIVE (Below Footing)
Basement level 1.0 2006.93 1.00 2006.93
13.2 1.2MM CROSS LAMINATED SBS MODIFIED MEMBRANE + 8MM THK HDPE PROTECTION BOARD
Basement level 1.0 854.57 1.00 854.57
13.3 1.2 mm HDPE MEMBRANE PRESSURE SENSITIVE ADHESIVE (below grade slab)
Basement level 1.0 2761.90 1.00 2761.90
13.3 1.2MM CROSS LAMINATED SBS MODIFIED MEMBRANE + 8MM THK HDPE PROTECTION BOARD
Basement level 1.0 355.35 1.00 355.35
14 COPING FINISH
14.1 COPING 1 CODE-A12-08 & 4/A11-01
Basement Floor Sqm 0.00 1.00 0.00
Lower Ground Floor Sqm 0.00 1.00 0.00
Mezzanine Floor Sqm 0.00 1.00 0.00
Ground Floor Sqm 0.00 1.00 0.00
First Floor Sqm 0.00 1.00 0.00
Second Floor Sqm 0.00 1.00 0.00
Third Floor Sqm 0.00 1.00 0.00
Fourth Floor Sqm 63.37 1.00 63.37
Total Sqm 63.37 67.00
14.2 COPING 2 CODE-A12-08 & 1/A11-01
Basement Floor Sqm 0.00 1.00 0.00
Lower Ground Floor Sqm 0.00 1.00 0.00
Mezzanine Floor Sqm 0.00 1.00 0.00
Ground Floor Sqm 0.00 1.00 0.00
First Floor Sqm 19.67 1.00 19.67
Second Floor Sqm 0.00 1.00 0.00
Third Floor Sqm 0.00 1.00 0.00
Fourth Floor Sqm 0.00 1.00 0.00
Roof Floor Sqm 213.06 1.00 213.06
Total Sqm 232.73 245.00
14.3 COPING 3 CODE-A12-08 & 2/A11-01
Basement Floor Sqm 0.00 1.00 0.00
Lower Ground Floor Sqm 0.00 1.00 0.00
Mezzanine Floor Sqm 0.00 1.00 0.00
Ground Floor Sqm 0.00 1.00 0.00
First Floor Sqm 0.00 1.00 0.00
Second Floor Sqm 0.00 1.00 0.00
Third Floor Sqm 0.00 1.00 0.00
Fourth Floor Sqm 0.00 1.00 0.00
Roof Floor Sqm 7.53 1.00 7.53
Total Sqm 7.53 8.00
14.4 COPING 4 CODE-A12-08 & 3/A11-01
Basement Floor Sqm 0.00 1.00 0.00
Lower Ground Floor Sqm 0.00 1.00 0.00
Mezzanine Floor Sqm 0.00 1.00 0.00
Ground Floor Sqm 0.00 1.00 0.00
First Floor Sqm 0.00 1.00 0.00
Second Floor Sqm 0.00 1.00 0.00
Third Floor Sqm 0.00 1.00 0.00
Fourth Floor Sqm 0.00 1.00 0.00
Roof Floor Sqm 13.06 1.00 13.06
Total Sqm 13.06 14.00
14.6 COPING 5 CODE-A12-08 & 6/A11-01
Basement Floor Sqm 1.00 0.00
Lower Ground Floor Sqm 1.00 0.00
Mezzanine Floor Sqm 1.00 0.00
Ground Floor Sqm 1.00 0.00
First Floor Sqm 1.00 0.00
Second Floor Sqm 1.00 0.00
Third Floor Sqm 1.00 0.00
Fourth Floor Sqm 1.00 0.00
Total Sqm 0.00 0.00
ROLLER BLIND CODE-12-04
Basement Floor Sqm 0.00 1.00 0.00
Lower Ground Floor Sqm 131.61 1.00 131.61
Mezzanine Floor Sqm 0.00 1.00 0.00
Ground Floor Sqm 182.77 1.00 182.77
First Floor Sqm 290.55 1.00 290.55
Second Floor Sqm 43.20 1.00 43.20
Third Floor Sqm 0.00 1.00 0.00
Fourth Floor Sqm 0.00 1.00 0.00
Total Sqm 648.13 681.00
GRANITE COUNTER Cum 18.00 0.075 1.35
25MM THICK STEEL GREY GRANITE FLOORING Cum 252.00 0.075 18.90
25 MM THICK GRAY GRANITE FLOORING Cum 65.00 0.075 4.88
MANDANA-1 (25MM THICK GRANITE) FLOORING Cum 1517.00 0.075 113.78
MANDANA-2 (25MM THICK GRANITE) FLOORING Cum 287.00 0.075 21.53
25MM THICK SANDSTONE Cum 0.00 0.075 0.00
25MM THICK POLISHED KOTA STONE FLOORING Cum 3445.00 0.075 258.38
25MM THICK KOTA STONE FLOORING Cum 423.00 0.075 31.73
KOTA STONE Cum 0.00 0.075 0.00
10 MM THICK VITRIFIED TILES FLOORING Cum 154.00 0.075 11.55
S.S WALK OF MATT Cum 35.00 0.081 2.84
G.I WALK OF MATT Cum 33.00 0.081 2.67
VDF CONCERETE FLOORING Cum 182.00 0.075 13.65
WOODEN DECK Cum 25.00 0.125 3.13
RUBBER TILE FLOORING Cum 11.00 0.075 0.83
Total Cum 483.83 509.00
SELF LEVELLING MORTAR
GI WALK OFF GRATING Sqm 30.85 1.000 30.85
SS WALK OFF GRATING Sqm 32.67 1.000 32.67
CARPET TILE FLOORING Sqm 648.86 1.000 648.86
WOODEN DECK FLOORIGN Sqm 23.43 1.000 23.43
RUBBER TILE FLOORING Sqm 9.78 1.000 9.78
Total Sqm 745.59 783.00
EXPANSION JOINT-EXTERIOR CODE-A12-13 & A11-03
2 ROOF TYPE - 1 (1-A11-03)
Basement Floor Rmt 0.00 1.00 0.00
Lower Ground Floor Rmt 0.00 1.00 0.00
Mezzanine Floor Rmt 0.00 1.00 0.00
Ground Floor Rmt 0.00 1.00 0.00
First Floor Rmt 0.00 1.00 0.00
Second Floor Rmt 0.00 1.00 0.00
Third Floor Rmt 0.00 1.00 0.00
Fourth Floor Rmt 10.72 1.00 10.72
Total Rmt 10.72 12.00
2 ROOF TYPE - 2 (2-A11-03)
Basement Floor Rmt 0.00 1.00 0.00
Lower Ground Floor Rmt 0.00 1.00 0.00
Mezzanine Floor Rmt 0.00 1.00 0.00
Ground Floor Rmt 0.00 1.00 0.00
First Floor Rmt 0.00 1.00 0.00
Second Floor Rmt 15.80 1.00 15.80
Third Floor Rmt 0.00 1.00 0.00
Fourth Floor Rmt 19.65 1.00 19.65
Total Rmt 35.45 38.00
3 ROOF TYPE - 3 (A11-03)
Basement Floor Rmt 0.00 1.00 0.00
Lower Ground Floor Rmt 13.46 1.00 13.46
Mezzanine Floor Rmt 0.00 1.00 0.00
Ground Floor Rmt 59.11 1.00 59.11
First Floor Rmt 0.00 1.00 0.00
Second Floor Rmt 6.20 1.00 6.20
Third Floor Rmt 0.00 1.00 0.00
Fourth Floor Rmt 4.25 1.00 4.25
Total Rmt 83.01 88.00
4 WALL TYPE - 1 (4-A11-03)
Basement Floor Rmt 0.00 1.00 0.00
Lower Ground Floor Rmt 0.00 1.00 0.00
Mezzanine Floor Rmt 0.00 1.00 0.00
Ground Floor Rmt 24.00 1.00 24.00
First Floor Rmt 28.80 1.00 28.80
Second Floor Rmt 0.00 1.00 0.00
Third Floor Rmt 0.00 1.00 0.00
Fourth Floor Rmt 0.00 1.00 0.00
Total Rmt 52.80 56.00
Basement Floor Rmt 0.00 1.00 0.00
Lower Ground Floor Rmt 14.40 1.00 14.40
Mezzanine Floor Rmt 19.20 1.00 19.20
Ground Floor Rmt 24.00 1.00 24.00
First Floor Rmt 21.60 1.00 21.60
Second Floor Rmt 10.20 1.00 10.20
Third Floor Rmt 0.00 1.00 0.00
Fourth Floor Rmt 0.00 1.00 0.00
Total Rmt 89.40 94.00
9.2 EXPANSION JOINT-INTERIOR CODE-A12-13 & A11-03
1 WALL TYPE-3 (5-A14-11)
Basement Floor Rmt 0.00 1.00 0.00
Lower Ground Floor Rmt 64.80 1.00 64.80
Mezzanine Floor Rmt 9.60 1.00 9.60
Ground Floor Rmt 18.00 1.00 18.00
First Floor Rmt 21.60 1.00 21.60
Second Floor Rmt 0.00 1.00 0.00
Third Floor Rmt 0.00 1.00 0.00
Fourth Floor Rmt 0.00 1.00 0.00
Total Rmt 114.00 120.00
2 FLOORING TYPE-1 (1-A14-11)
Basement Floor Rmt 0.00 1.00 0.00
Lower Ground Floor Rmt 0.00 1.00 0.00
Mezzanine Floor Rmt 0.00 1.00 0.00
Ground Floor Rmt 19.60 1.00 19.60
First Floor Rmt 8.70 1.00 8.70
Second Floor Rmt 0.00 1.00 0.00
Third Floor Rmt 0.00 1.00 0.00
Fourth Floor Rmt 0.00 1.00 0.00
Total Rmt 28.30 30.00
3 FLOORING TYPE-2 (2-A14-11)
Basement Floor Rmt 0.00 1.00 0.00
Lower Ground Floor Rmt 0.00 1.00 0.00
Mezzanine Floor Rmt 0.00 1.00 0.00
Ground Floor Rmt 18.69 1.00 18.69
First Floor Rmt 24.43 1.00 24.43
Second Floor Rmt 0.00 1.00 0.00
Third Floor Rmt 0.00 1.00 0.00
Fourth Floor Rmt 0.00 1.00 0.00
Total Rmt 43.12 46.00
4 FLOORING TYPE-3 (3-A14-11)
Basement Floor Rmt 0.00 1.00 0.00
Lower Ground Floor Rmt 0.00 1.00 0.00
Mezzanine Floor Rmt 3.42 1.00 3.42
Ground Floor Rmt 6.84 1.00 6.84
First Floor Rmt 6.84 1.00 6.84
Second Floor Rmt 1.50 1.00 1.50
Third Floor Rmt 0.00 1.00 0.00
Fourth Floor Rmt 0.00 1.00 0.00
Total Rmt 18.60 20.00
5 FLOORING TYPE-4 (4-A14-11)
Basement Floor Rmt 0.00 1.00 0.00
Lower Ground Floor Rmt 0.00 1.00 0.00
Mezzanine Floor Rmt 0.00 1.00 0.00
Ground Floor Rmt 9.51 1.00 9.51
First Floor Rmt 7.22 1.00 7.22
Second Floor Rmt 5.51 1.00 5.51
Third Floor Rmt 0.00 1.00 0.00
Fourth Floor Rmt 0.00 1.00 0.00
Total Rmt 22.24 24.00
SuPr ENGINEERING CONSULTANTS 307, SIDDHARTH UPSCALE, VASNA ROAD VADODARA-390007 TEL- 0265-3149701 MEASUREMENT
PROJECT : GUJARAT VANDANA MUSEUM, GUJARAT
VADODARA ARCHITECT : OPOLIS
DATE : 05-09-25 CLIENT : DIRECTORATE OF ARCHEOLOGY AND MUSEUMS, G.O.G
PREPARED BY : MANDIPSINH CHECKED BY :
SR.NO. PARTICULARS NO. L B D QTY.
2.3 150MM THICK FLY ASH BLOCK MASONRY CODE-A13-01 & 1/A13-08
LOWER GROUND FLOOR PLAN
Drg Title : GVM_A4_DETAILED PLAN
Drg Date : 11-09-2025
GROUND FLOOR PLAN
Drg Title : GVM_A4_DETAILED PLAN
Drg Date : 11-09-2025
2.4 200MM THICK AAC BLOCK MASONRY CODE-A13-01 & 1/A13-08
GROUND FLOOR PLAN
Drg Title : GVM_A4_DETAILED PLAN
Drg Date : 11-09-2025
Drg Title : GVM_A4_DETAILED PLAN
Drg Date : 11-09-2025
2.5 250MM THICK FLY ASH BLOCK MASONRY CODE-A13-01 & 1/A13-08
LOWER GROUND FLOOR PLAN
Drg Title : GVM_A4_DETAILED PLAN
Drg Date : 11-09-2025
GROUND FLOOR PLAN
Drg Title : GVM_A4_DETAILED PLAN
Drg Date : 11-09-2025
audi green room toilet 1.0 2.57 0.25 5.40 3.47
conyrol room 1.0 4.35 0.25 5.40 5.87
oriantation gallery 1.0 1.55 0.25 5.40 2.09
service passage 1.0 4.95 0.25 5.40 6.68
Drg Title : GVM_A4_DETAILED PLAN
Drg Date : 11-09-2025
2.6 300MM THICK FLY ASH BLOCK MASONRY CODE-A13-01 & 1/A13-08
LOWER GROUND FLOOR PLAN
Drg Title : GVM_A4_DETAILED PLAN
Drg Date : 11-09-2025
2.7 350MM THICK AAC BLOCK MASONRY CODE-A13-01 & 1/A13-08
Drg Title : GVM_A4_DETAILED PLAN
Drg Date : 11-09-2025
3 DRY PARTITION
3.1 100 MM THICK DRY PARTITION WITHOUT INSULATION CODE-A13-01 & 2/A13-08
Drg Title : GVM_A4_DETAILED PLAN
Drg Date : 11-09-2025
4.1 150 MM THICK AAC BLOCK MASONRY CODE-01A13-08
LOWER GROUND FLOOR PLAN
Drg Title : GVM_A4_DETAILED PLAN
Drg Date : 11-09-2025
4.2 200 MM THICK AAC BLOCK MASONRY CODE-01A13-08
LOWER GROUND FLOOR PLAN
Drg Title : GVM_A4_DETAILED PLAN
Drg Date : 11-09-2025
janitor room 1.0 1.53 0.20 3.40 1.04
Drg Title : GVM_A4_DETAILED PLAN
Drg Date : 11-09-2025
4.3 250 MM THICK AAC BLOCK MASONRY CODE-01A13-08
LOWER GROUND FLOOR PLAN
Drg Title : GVM_A4_DETAILED PLAN
Drg Date : 11-09-2025
chiller room 1.0 3.70 0.25 3.40 3.15
staff break room 2.0 1.20 0.25 3.40 2.04
industrical first aid 1.0 2.78 0.25 3.40 2.36
staff toilet-M & F 1.0 5.65 0.25 3.00 4.24
server room & security monitoir 1.0 3.48 0.25 3.40 2.96
qurantine room 1.0 6.40 0.25 3.40 5.44
tool storage & exhb prep dirty room 1.0 7.22 0.25 7.25 13.09
tool storage & exhb prep clean room 1.0 7.22 0.25 7.25 13.09
collection storage 1.0 6.45 0.25 7.25 11.69
security lockers 1.0 4.92 0.25 8.20 10.09
moving tool storage 1.0 6.75 0.25 7.10 11.98
crate storage 1.0 5.12 0.25 7.10 9.09
shipping/receiving 1.0 7.10 0.25 7.10 12.60
transit store 1.0 6.49 0.25 7.10 11.51
metering kiosk 2.0 3.45 0.25 7.90 13.63
waste management 2.0 3.45 0.25 7.10 12.25
MEZZANINE FLOOR PLAN
Drg Title : GVM_A4_DETAILED PLAN
Drg Date : 11-09-2025
housekeeping 1.0 6.35 0.25 4.60 7.30
fire esc staircase 1.0 2.00 0.25 4.60 2.30
staff locker room-M & F 1.0 4.46 0.25 4.20 4.68
electrical room 1.0 7.20 0.25 4.60 8.28
GROUND FLOOR PLAN
Drg Title : GVM_A4_DETAILED PLAN
Drg Date : 11-09-2025
oriantation gallery 1.0 6.10 0.25 5.40 8.24
Drg Title : GVM_A4_DETAILED PLAN
Drg Date : 11-09-2025
AHU gaurav gallery 1.0 2.45 0.25 7.15 4.38
Drg Title : GVM_A4_DETAILED PLAN
Drg Date : 11-09-2025
3 INTERNAL PLATSER WORK Floor ht = 3.60
LOWER GROUND FLOOR 3.40
Drg Title : FINISHES DIAGRAM-INT WALLS
Drg No : A12-05
Drg Date : 25-09-2025
Plaster Gas Bank 2.0 6.10 3.42 41.66
Plaster Gas Bank 2.0 4.30 3.42 29.37
add jambs & soffits 1.0 6.60 0.15 0.99
add jambs & soffits 1.0 7.75 0.15 1.16
Plaster EXHIBITS & COLLECTION 1.0 41.74 3.40 141.92
on columns 1.0 3.00 3.40 10.20
add jambs & soffits 1.0 8.70 0.15 1.31
Plaster LOADING/UNLOADING BAY (A9-10 sec 13) 1.0 49.28 8.80 433.62
add jambs & soffits 1.0 12.75 0.15 1.91
Plaster TRANSIT STORE (A9-10 sec 12) 1.0 39.40 8.20 323.08
add jambs & soffits 1.0 8.70 0.15 1.31
Plaster METERING KIOSK (A9-10 sec 12) 1.0 27.66 7.90 218.48
add jambs & soffits 1.0 5.70 0.15 0.86
Plaster WASTE MANAGEMENT ( A9-12 sec 16) 1.0 21.89 8.20 179.53
add jambs & soffits 1.0 6.00 0.15 0.90
add jambs & soffits 1.0 5.70 0.15 0.86
add jambs & soffits 1.0 5.70 0.15 0.86
Plaster STORAGE 2.0 3.28 3.40 22.27
Plaster INDUSTRIAL FIRST AID 1.0 11.15 p-line 3.40 37.91
Plaster STAFF BREAK RM (A9-09 sec 11) 2.0 7.45 3.40 50.66
Plaster UPS Bank 2.0 3.83 3.40 26.01
Plaster Chillar rm 1.0 3.70 8.20 30.34
Plaster Chillar rm 1.0 18.95 8.20 155.39
add jambs & soffits 1.0 8.70 0.15 1.31
Plaster Chillar rm 1.0 16.29 8.20 133.54
plaster SERVER RM (A9-02 sec 4) 1.0 2.68 6.30 16.85
plaster SECURITY MONITOR (A9-06 sec 8) 1.0 25.27 3.25 82.13
plaster QUARANTINE+CONSERVE+EXAMINE LAB (A9-06 sec 8 ) 1.0 35.53 3.25 115.47
add jambs & soffits 1.0 8.70 0.15 1.31
plaster Av store (A9-06 sec 8 same as IT rm ) 1.0 29.85 7.10 211.94
on columns 1.0 3.00 7.10 21.30
plaster IT work rm (A9-06 sec 8) 1.0 30.28 7.10 214.99
on columns 2.0 3.00 7.10 42.60
plaster PLINTH & PANEL (A9-06 sec 8 same as IT) 1.0 40.66 7.10 288.69
on columns 2.0 3.00 7.10 42.60
add jambs & soffits 1.0 8.70 0.15 1.31
plaster Collection storage 1.0 45.64 7.10 324.01
add jambs & soffits 1.0 8.70 0.15 1.31
add jambs & soffits 1.0 8.70 0.15 1.31
SERVICE SHIPPING RECEIVING (A9-10 SEC 13) 1.0 12.87 P-line 8.20 105.53
SHIPPING/RECEIVING SECURITY (A9-10 SEC 13) 1.0 17.13 P-line 8.20 140.43
CRATE STORAGE (A9-10 SEC 13) 1.0 16.00 P-line 8.20 131.20
MOVING TOOLS STORAGE (A9-10 SEC 13) 1.0 17.19 P-line 8.20 140.96
SECURITY READY LOCKERS (A9-07 SEC 09) 1.0 19.14 P-line 8.20 156.95
4.2m wide Service Passage 1.0 131.35 P-line 8.20 1077.07
3.6m wide Service Pasage 1.0 192.62 8.20 1579.48
Ded Of extra length 1.0 8.80 8.20 72.16
Plaster Wall on middle block 1.0 96.80 8.20 793.74
Lift Wall Ded -1.0 1.10 2.10 -2.31
MEZZANINE FLOOR
Drg Title : FINISHES DIAGRAM-INT WALLS
Drg No : A12-05 Floor ht = 4.70
Drg Date : 25-09-2025 Slab = 0.20
plaster AHU (A9-06 sec 08) 1.0 48.61 P-LINE 4.50 218.75
add jambs & soffits 1.0 5.70 0.15 0.86
plaster ELECTRICAL RM (A9-09 sec 11) 2.0 5.67 4.50 51.03
plaster BMS RM (A9-09 sec 11) 2.0 5.55 4.50 49.95
plaster Male staff locker rm 1.0 20.58 P-LINE 4.50 92.61
plaster Female staff locker rm 1.0 15.45 P-LINE 4.50 69.50
plaster HOUSEKEEPING CENTRE (A9-06 sec 8) 1.0 30.15 P-LINE 4.50 135.68
plaster MEZZANINE PASSAGE (A9-07 sec 9) 1.0 114.03 P-LINE 4.50 513.12
add jambs & soffits 1.0 5.70 0.15 0.86
add jambs & soffits 1.0 5.70 0.15 0.86
add jambs & soffits 1.0 5.70 0.15 0.86
add jambs & soffits 1.0 8.70 0.15 1.31
add jambs & soffits 1.0 5.40 0.15 0.81
add jambs & soffits 1.0 5.40 0.15 0.81
add jambs & soffits 1.0 5.40 0.15 0.81
add jambs & soffits 1.0 5.40 0.15 0.81
add jambs & soffits 1.0 5.40 0.15 0.81
add jambs & soffits 1.0 5.40 0.15 0.81
add jambs & soffits 1.0 5.40 0.15 0.81
GROUND FLOOR Floor ht = 6.00
Drg Title : FINISHES DIAGRAM-INT WALLS Slab = 0.20
Drg No : A12-05 5.80
Drg Date : 25-09-2025
plaster RESTAURANT OUTDOOR (A9-11 sec 14) 1.0 43.90 P-LINE 5.80 254.62
add jambs & soffits 1.0 16.80 0.15 2.52
add jambs & soffits 1.0 13.20 0.15 1.98
add jambs & soffits 1.0 17.59 0.15 2.64
plaster RESTAURANT INDOOR (A9-11 sec 14) 1.0 75.12 P-LINE 5.80 435.69
add jambs & soffits 1.0 6.60 0.15 0.99
add jambs & soffits 1.0 9.60 0.15 1.44
add jambs & soffits 1.0 10.20 0.15 1.53
add jambs & soffits 1.0 10.20 0.15 1.53
add jambs & soffits 1.0 10.20 0.15 1.53
add jambs & soffits 1.0 10.20 0.15 1.53
add jambs & soffits 1.0 10.20 0.15 1.53
add jambs & soffits 1.0 10.20 0.15 1.53
add jambs & soffits 1.0 10.20 0.15 1.53
add jambs & soffits 1.0 10.10 0.15 1.52
pls Kitchen (A9-11 sec 15) 1.0 34.03 P-LINE 5.80 197.35
add jambs & soffits 1.0 6.60 0.15 0.99
add jambs & soffits 1.0 5.70 0.15 0.86
add jambs & soffits 1.0 5.70 0.15 0.86
pls Kitchen 2.0 6.00 5.80 69.60
On door wall 4.0 2.00 5.80 46.40
add jambs & soffits 1.0 5.70 0.15 0.86
add jambs & soffits 1.0 5.70 0.15 0.86
on wall 1.0 36.94 P-LINE 5.80 214.25
plaster AHU 2.0 4.53 5.80 52.55
add jambs & soffits 1.0 5.70 0.15 0.86
plaster MULTIPURPOSE HALL (A9-11 sec 11) 1.0 56.75 P-LINE 5.80 329.15
add jambs & soffits 1.0 8.70 0.15 1.31
add jambs & soffits 1.0 10.20 0.15 1.53
add jambs & soffits 1.0 6.30 0.15 0.95
plaster FOLDING FURNITURE STORE (A9-11 sec 11) 1.0 19.40 5.70 110.58
add jambs & soffits 1.0 6.30 0.15 0.95
plaster FIRST AID 1.0 14.39 5.80 83.47
add jambs & soffits 1.0 6.30 0.15 0.95
plaster 3.4 wide passage (A9-07 sec 09) 1.0 81.39 P-LINE 5.80 472.03
add jambs & soffits 1.0 5.70 0.15 0.86
less Lift opn -1.0 2.30 2.30 -5.29
add jambs & soffits 1.0 6.90 0.15 1.03
Less lift opn -1.0 2.10 1.10 -2.31
add jambs & soffits 1.0 6.30 0.15 0.95
add jambs & soffits 1.0 5.70 0.15 0.86
add jambs & soffits 1.0 8.70 0.15 1.31
plaster Audi exit (A9-01 sec 2) 1.0 14.05 P-LINE 5.80 81.49
add jambs & soffits 1.0 6.60 0.15 0.99
add jambs & soffits 1.0 6.60 0.15 0.99
plaster Control rm (A9-01 sec 02) 2.0 7.10 5.80 82.36
add jambs & soffits 1.0 5.40 0.15 0.81
add jambs & soffits 1.0 6.60 0.15 0.99
plaster room beside ahu (A9-03 Sec 05) 2.0 2.25 3.79 17.03
add jambs & soffits 1.0 6.60 0.15 0.99
add jambs & soffits 1.0 6.60 0.15 0.99
Plaster Bhasa gallery (A9-03 Sec 05) 1.0 20.10 5.80 116.58
add jambs & soffits 1.0 6.60 0.15 0.99
add jambs & soffits 1.0 9.90 0.15 1.49
plaster Green Rm (A9-05 sec 7) 1.0 10.72 5.80 62.15
add jambs & soffits 1.0 5.70 0.15 0.86
add jambs & soffits 1.0 6.30 0.15 0.95
plaster Green Rm 1.0 12.00 6.20 74.40
plaster Green Rm 1.0 27.81 6.70 186.30
less wall opn -1.0 8.32 1.65 -13.74
plaster Auditorium (A9-04 sec 06)
Leaning bar wall 1.0 5.00 5.80 29.00
Seating wall 1.0 7.50 6.45 48.38
Stand wall 1.0 2.25 7.40 16.65
front screen wall 1.0 8.32 5.15 42.87
Lobby near auditorium (A9-01) 1.0 75.79 5.80 439.58
Less lift opn -0.5 1.20 2.40 -1.44
add jambs & soffits 1.0 9.00 0.15 1.35
7.2mm wide public corridor 1.0 135.50 5.80 785.92
Ded Of entrance lobby wall length -1.0 8.98 5.80 -52.06
1ST FLOOR Floor ht = 7.20
Drg Title : FINISHES DIAGRAM-INT WALLS Slab = 0.20
Drg No : A12-05 7.00
Drg Date : 25-09-2025
Plaster BOUNTIFUL GUJARAT (A9-11 sec 15) 1.0 66.52 P-LINE 7.00 465.64
add jambs & soffits 1.0 6.30 0.15 0.95
add jambs & soffits 1.0 8.70 0.15 1.31
add jambs & soffits 1.0 14.90 0.15 2.24
Plaster AHU (A9-10 sec 13) 1.0 25.68 P-LINE 7.00 179.73
add jambs & soffits 1.0 5.70 0.15 0.86
plaster GAURAV GALLERY (A9-09 sec 11) 1.0 63.68 P-LINE 7.00 445.73
add jambs & soffits 1.0 14.30 0.15 2.15
add jambs & soffits 1.0 8.70 0.15 1.31
add jambs & soffits 1.0 6.30 0.15 0.95
add jambs & soffits 1.0 14.90 0.15 2.24
plaster AHU (A9-06) 1.0 27.00 P-LINE 7.00 189.00
add jambs & soffits 1.0 5.70 0.15 0.86
plaster 3.4M WIDE PASSAGE (A9-12 sec 16) 1.0 70.44 7.00 493.08
LESS LIFT OPN -2.0 1.10 2.10 -4.62
LESS LIFT OPN -1.0 2.30 2.30 -5.29
plaster GAURAV GALLERY (A9-04 sec 06) 1.0 72.73 7.00 509.11
add jambs & soffits 1.0 14.30 0.15 2.15
add jambs & soffits 1.0 6.30 0.15 0.95
add jambs & soffits 1.0 8.70 0.15 1.31
plaster AHU (A9-01 sec 01) 1.0 25.86 P-LINE 7.00 181.02
add jambs & soffits 1.0 5.40 0.15 0.81
plaster Lobby (A9-03) 1.0 3.05 6.00 18.30
plaster Lobby (A9-01) 1.0 3.48 6.90 23.98
plaster Lobby (A9-01) 1.0 9.73 6.90 67.10
Less lift opn -0.5 1.20 2.10 -1.26
2ND FLOOR Floor ht = 4.85
Drg Title : FINISHES DIAGRAM-INT WALLS Slab = 0.20
Drg No : A12-05 4.65
Drg Date : 25-09-2025
add jambs & soffits 1.0 5.70 0.50 2.85
add jambs & soffits 1.0 6.00 0.15 0.90
LESS LIFT OPN -1.0 1.10 2.10 -2.31
PL CONFERENCE 1.0 6.52 4.65 30.32
add jambs & soffits 4.0 6.00 0.15 3.60
PL BUILDING MANAGEMENT 1.0 3.85 3.30 12.71
add jambs & soffits 2.0 6.00 0.15 1.80
PL Rm beside B.M 1.0 5.50 4.65 1.80
add jambs & soffits 2.0 6.00 0.15 1.80
PL CURATORIAL 4.0 3.40 3.30 44.88
add jambs & soffits 3.0 6.00 0.15 2.70
PL CURATORIAL 1.0 3.40 3.30 11.22
PL ADMIN & MEETING RM 1.0 7.23 4.65 33.60
add jambs & soffits 3.0 13.42 0.15 6.04
PL Director 1.0 10.98 4.65 51.07
PL RECEPTION 1.0 4.61 4.65 21.44
3 INTERNAL PUTTY WORK Floor ht = 3.60
LOWER GROUND FLOOR 3.40
Drg Title : FINISHES DIAGRAM-INT WALLS
Drg No : A12-05
Drg Date : 25-09-2025
Putty UPS Bank 1.0 12.20 3.40 41.48
add jambs & soffits 1.0 6.00 0.15 0.90
Putty CHILLER RM (A9-08 1) 1.0 14.18 8.20 116.24
Putty chillar rm on column 1.0 3.00 8.20 24.60
SERVICE SHIPPING RECEIVING (A9-10 SEC 13) 1.0 12.87 P-line 8.20 105.53
SHIPPING/RECEIVING SECURITY (A9-10 SEC 13) 1.0 9.48 P-line 8.20 77.69
CRATE STORAGE (A9-10 SEC 13) 1.0 8.38 P-line 8.20 68.68
MOVING TOOLS STORAGE (A9-10 SEC 13) 1.0 9.50 P-line 8.20 77.90
SECURITY READY LOCKERS (A9-07 SEC 09) 1.0 8.07 P-line 8.20 66.22
MEZZANINE FLOOR
Drg Title : FINISHES DIAGRAM-INT WALLS
Drg No : A12-05
Drg Date : 25-09-2025
putty ST-B1 1.0 43.67 P-LINE 4.80 209.62
add jambs & soffits 1.0 5.70 0.15 0.86
add jambs & soffits 1.0 5.70 0.15 0.86
putty ST-A1 1.0 31.89 P-LINE 4.80 153.05
add jambs & soffits 1.0 5.70 0.15 0.86
GROUND FLOOR Floor ht = 6.00
Drg Title : FINISHES DIAGRAM-INT WALLS Slab = 0.20
Drg No : A12-05 5.80
Drg Date : 25-09-2025
putty Kitchen (A9-11 sec 15) 1.0 39.18 5.80 227.24
add jambs & soffits 1.0 5.70 0.15 0.86
putty ST-C1 1.0 26.20 P-LINE 6.00 157.20
add jambs & soffits 1.0 5.40 0.15 0.81
add jambs & soffits 1.0 5.70 0.15 0.86
putty ST-B1 1.0 43.67 P-LINE 6.00 262.02
add jambs & soffits 1.0 5.70 0.15 0.86
add jambs & soffits 1.0 5.70 0.15 0.86
putty ST-A1 1.0 26.01 P-LINE 6.00 156.06
add jambs & soffits 1.0 6.30 0.15 0.95
putty 3.4 wide passage (A9-07 Sec 09) 1.0 64.54 P-LINE 5.80 374.33
add jambs & soffits 1.0 5.40 0.15 0.81
add jambs & soffits 1.0 5.40 0.15 0.81
add jambs & soffits 1.0 5.40 0.15 0.81
add jambs & soffits 1.0 5.40 0.15 0.81
add jambs & soffits 1.0 5.40 0.15 0.81
add jambs & soffits 1.0 5.40 0.15 0.81
Putty Bhasa gallery (A9-003 sec 05) 1.0 53.10 5.80 307.98
Putty Green Rm (A9-05 sec 7) 1.0 8.16 5.80 47.36
add jambs & soffits 1.0 5.70 0.15 0.86
1ST FLOOR Floor ht = 7.20
Drg Title : FINISHES DIAGRAM-INT WALLS Slab = 0.20
Drg No : A12-05 7.00
Drg Date : 25-09-2025
Putty BOUNTIFUL GUJARAT (A9-11 sec 15) 1.0 71.65 P-LINE 7.00 501.55
PUTTY GAURAV GALLERY (A9-06 sec 11) 1.0 42.93 P-LINE 5.90 253.26
PUTTY 3.4M WIDE PASSAGE (A9-12 sec 16) 1.0 63.09 7.00 441.63
add jambs & soffits 1.0 5.40 0.15 0.81
add jambs & soffits 1.0 5.40 0.15 0.81
add jambs & soffits 1.0 5.40 0.15 0.81
add jambs & soffits 1.0 5.40 0.15 0.81
add jambs & soffits 1.0 5.40 0.15 0.81
pu GAURAV GALLERY (A9-04 sec 06) 1.0 60.63 7.00 424.41
add jambs & soffits 1.0 8.80 0.50 4.40
putty ST-C1 1.0 26.20 P-LINE 7.00 183.40
add jambs & soffits 1.0 5.40 0.15 0.81
add jambs & soffits 1.0 5.70 0.15 0.86
putty ST-B1 1.0 43.67 P-LINE 7.00 305.69
add jambs & soffits 1.0 5.70 0.15 0.86
add jambs & soffits 1.0 5.70 0.15 0.86
putty ST-A1 1.0 26.01 P-LINE 7.00 182.07
add jambs & soffits 1.0 6.30 0.15 0.95
2ND FLOOR Floor ht = 4.85
Drg Title : FINISHES DIAGRAM-INT WALLS Slab = 0.20
Drg No : A12-05 4.65
Drg Date : 25-09-2025
PU STAIRCASE 1.0 23.52 4.65 109.37
add jambs & soffits 3.0 32.82 0.15 14.77
PU Recption 1.0 9.12 4.65 42.38
PU workstation 1.0 2.92 4.65 13.58
CEILING PUTTY WORK
LOWER GROUND FLOOR (TOP)
Drg No : A12-05
Drg Date : 25-09-2025
EXHIBITS & COLLECTION 1.0 23.65 P-AREA 23.65
LOADING/UNLOADING BAY 1.0 48.26 P-AREA 48.26
METERING KIOSK 1.0 35.88 P-AREA 35.88
TRANSIT STORE 1.0 24.81 P-AREA 24.81
WASTE MANAGEMENT 1.0 17.72 P-AREA 17.72
WASTE MANAGEMENT 1.0 3.08 2.30 7.08
PASSAGE NR LIFT B1 & B2 1.0 40.65 P-AREA 40.65
UPS BANK 1.0 32.84 P-AREA 32.84
CHILLAR RM 1.0 69.91 P-AREA 69.91
MEZZANINE FLOOR (TOP)
Drg No : A12-05
Drg Date : 25-09-2025
MEZZANINE PASSAGE 1.0 101.09 P-AREA 101.09
HOUSEKEEPING CENTRE 1.0 37.05 P-AREA 37.05
ST-A1 EXIT LOBBY 1.0 7.77 P-AREA 7.77
GROUND FLOOR (TOP)
Drg No : A12-05
Drg Date : 25-09-2025
KITCHEN 1.0 111.69 P-AREA 111.69
3.4 M WIDE SERVICE PASSSAGE 1.0 37.69 P-AREA 37.69
3.4 M WIDE SERVICE PASSSAGE 1.0 127.24 P-AREA 127.24
1ST FLOOR (TOP)
Drg No : A12-05
Drg Date : 25-09-2025
BOUNTIFUL GUJARAT 1.0 65.73 P-AREA 65.73
AHU 1.0 30.76 P-AREA 30.76
3.4 M WIDE SERVICE PASSSAGE 1.0 58.24 P-AREA 58.24
3.4 M WIDE SERVICE PASSSAGE 1.0 127.24 P-AREA 127.24
Lower Ground Floor
Drg Title : FINISHES DIAGRAM-INT WALLS
Drg No : A12-05
Drg Date : 25-09-2025
Male Staff Toilet 1.0 23.44 3.40 79.70
Female Staff Toilet 1.0 23.21 3.40 78.91
Mezzanine Floor
Drg Title : FINISHES DIAGRAM-INT WALLS
Drg No : A12-05
Drg Date : 25-09-2025
STAFF TOILET - MALE 1.0 23.46 4.50 105.57
STAFF TOILET - FEMALE 1.0 23.18 4.50 104.31
Drg Title : FINISHES DIAGRAM-INT WALLS
Drg No : A12-05
Drg Date : 25-09-2025
Female Toilet 1.0 30.32 5.80 175.83
Baby Feeding 2.0 3.55 5.80 41.12
Ded Of 3.0 m Height wall -1.0 3.25 2.80 -9.10
Male Toilet 1.0 48.03 5.80 278.57
Janitor Room 2.0 2.02 5.80 23.43
Ded Of 3.0 m Height wall -1.0 15.25 2.80 -42.70
Male Toilet 1.0 33.98 5.70 193.68
Janitor room 2.0 2.10 5.70 23.94
Female Toilet 1.0 27.46 5.70 156.49
Kitchen staff chng rm 2.0 3.27 5.80 37.93
Drg Title : FINISHES DIAGRAM-INT WALLS
Drg No : A12-05
Drg Date : 25-09-2025
Female Toilet 1.0 27.22 6.95 189.14
Male Toilet 1.0 31.59 6.95 219.55
Janitor Room 2.0 2.45 3.00 14.70
Drg Title : FINISHES DIAGRAM-INT WALLS
Drg No : A12-05
Drg Date : 25-09-2025
Female Toilet 1.0 12.80 P-line 4.75 60.80
Male Toilet 1.0 22.25 P-line 4.75 105.69
Pantry 1.0 10.25 P-line 4.75 48.69
Director toilet 2.0 2.20 4.65 20.46
EXTERNAL PLASTER
Lower Ground Floor
Drg Title : FINISHES DIAGRAM-INT WALLS
Drg No : A12-05
Drg Date : 25-09-2025
North block (Grid BH Y1 To GJ Y5 /A X1) 1.0 51.40 8.40 431.76
Ded of loading /Unloading bay -1.0 6.78 7.30 -49.49
Service Entry (A9-22 sec 32) 1.0 26.27 8.35 219.38
Mezzanine Floor
Drg Title : FINISHES DIAGRAM-INT WALLS
Drg No : A12-05
Drg Date : 25-09-2025
North block 1.0 52.18 4.80 250.46
Drg Title : FINISHES DIAGRAM-INT WALLS
Drg No : A12-05
Drg Date : 25-09-2025
Drg Title : FINISHES DIAGRAM-INT WALLS
Drg No : A12-05
Drg Date : 25-09-2025
Drg Title : FINISHES DIAGRAM-INT WALLS
Drg No : A12-05
Drg Date : 25-09-2025
Parapet wall as per roof dwg 1.0 207.61 2.10 435.99
Gaurav Gallery double ht lobby 1.0 13.08 7.41 96.93
13 WATERPROOFING WORK
13.1 LOCATION : TOILET
LOWER GROUND FLOOR
(Location : MALE & FEMALE TOILET)
Drg Title : 2025-09-18_GVM_A0-12_SUNK DIAGRAM
Drg Date : 19-09-2025
Female Toilet 1.0 18.89 P-area 18.89
Male Toilet 1.0 17.70 P-area 17.70
Female Toilet 1.0 23.12 P-line 1.00 23.12
Male Toilet 1.0 24.43 P-line 1.00 24.43
MEZZANINE FLOOR
(Location : MALE & FEMALE TOILET)
Drg Title : 2025-09-18_GVM_A0-12_SUNK DIAGRAM
Drg Date : 19-09-2025
Female Toilet 1.0 18.89 P-area 18.89
Male Toilet 1.0 17.70 P-area 17.70
Female Toilet 1.0 23.12 P-line 1.00 23.12
Male Toilet 1.0 24.43 P-line 1.00 24.43
(Location :MALE & FEMALE TOILET)
Drg Title : 2025-09-18_GVM_A0-12_SUNK DIAGRAM
Drg Date : 19-09-2025
Kitchen Toilet 1.0 3.27 3.03 9.91
Male Toilet 1.0 41.28 P-area 41.28
Female Toilet 1.0 31.77 P-area 31.77
Male Toilet 1.0 32.49 P-area 32.49
Female Toilet 1.0 25.53 P-area 25.53
Audi Toilet 1.0 3.39 P-area 3.39
Audi Toilet 1.0 4.48 P-area 4.48
Kitchen Toilet 1.0 12.60 1.00 12.60
Male Toilet 1.0 48.03 P-line 1.00 48.03
Female Toilet 1.0 30.32 P-line 1.00 30.32
Male Toilet 1.0 33.98 P-line 1.00 33.98
Female Toilet 1.0 27.45 P-line 1.00 27.45
Audi Toilet 1.0 8.04 P-line 1.00 8.04
Audi Toilet 1.0 8.76 P-line 1.00 8.76
(Location : MALE & FEMALE TOILET)
Drg Title : 2025-09-18_GVM_A0-12_SUNK DIAGRAM
Drg Date : 19-09-2025
Male Toilet 1.0 39.03 P-area 39.03
Female Toilet 1.0 31.75 P-area 31.75
Male Toilet 1.0 41.99 P-line 1.00 41.99
Janitor Store 1.0 8.00 1.00 8.00
Female Toilet 1.0 30.23 P-line 1.00 30.23
(Location : MALE & FEMALE TOILET)
Drg Title : 2025-09-18_GVM_A0-12_SUNK DIAGRAM
Drg Date : 19-09-2025
Director Toilet 1.0 2.20 1.36 2.99
F-Toilet 1.0 8.23 P-area 8.23
M-Toilet 1.0 17.57 P-area 17.57
Female Toilet 1.0 12.80 P-line 1.00 12.80
Male Toilet 1.0 17.57 P-line 1.00 17.57
D.Toilet 1.0 7.12 P-line 1.00 7.12
13.5 LOCATION : LIFT PIT WATERPROOFING (INSIDE)
LOWER GROUND FLOOR
(Location : NORTH LIFT)
Drg Title : 2025-09-18_GVM_A0-12_SUNK DIAGRAM
Drg Date : 19-09-2025
13.5 LOCATION : LIFT PIT WATERPROOFING (OUTSIDE ON WALL)
LOWER GROUND FLOOR
(Location : ELIPTICAL LIFT)
Drg Title : 2025-09-18_GVM_A0-12_SUNK DIAGRAM
Drg Date : 19-09-2025
TANK WATERPROOFING
2nd Floor Level Plan (above 2nd floor)
(Location : TANKS)
Drg Title : GVM_A4_DETAILED PLAN
Drg Date : 11-09-2025
Domestic tank 1.0 4.15 2.44 10.13
Fire Fighting tank 1.0 18.02 2.40 43.25
Domestic tank 1.0 18.02 2.40 43.25
TEARRCE WATERPROOFING
Drg Title : 2025-09-18_GVM_A12-08,09-EXT ROOF ,COPING LVL DIAGRAM
Drg Date : 19-09-2025
North block roof 1.0 794.50 794.50
Drg Title : 2025-09-18_GVM_A12-08,09-EXT ROOF ,COPING LVL DIAGRAM
Drg Date : 19-09-2025
Bountiful gujarat roof 1.0 86.10 86.10
Drg Title : 2025-09-18_GVM_A12-08,09-EXT ROOF ,COPING LVL DIAGRAM
Drg Date : 19-09-2025
Green Roof 1.0 552.03 552.03
LOWER GROUND FLOOR
Drg Title : 2025-09-18_GVM_A0-12_SUNK DIAGRAM
Drg Date : 19-09-2025
Male Toilet 1.0 17.70 P-area 1.20 21.24
Female toilet 1.0 18.89 P-area 1.20 22.67
Ind.First Aid 1.0 8.03 P-area 1.20 9.64
Emergency shower area 1.0 1.20 1.20 0.90 1.30
MEZZANINE FLOOR
Drg Title : 2025-09-18_GVM_A0-12_SUNK DIAGRAM
Drg Date : 19-09-2025
Male Toilet 1.0 17.70 P-area 0.60 10.62
Female toilet 1.0 18.89 P-area 0.60 11.33
Housekeeping centre 1.0 37.10 2.77 0.60 61.66
Drg Title : 2025-09-18_GVM_A0-12_SUNK DIAGRAM
Drg Date : 19-09-2025
Kitchen 1.0 212.34 P-area 0.80 169.87
kitchen Changing room 1.0 3.27 3.03 0.60 5.94
Male Toilet 1.0 41.28 P-area 0.60 24.77
Female toilet 1.0 31.77 P-area 0.60 19.06
Baby feeding 1.0 3.55 2.68 0.60 5.69
Male Toilet 1.0 32.49 P-area 0.60 19.49
Female toilet 1.0 25.38 P-area 0.60 15.23
First aid 1.0 11.00 P-area 0.60 6.60
Audi Toilet 1.0 3.39 P-area 1.80 6.10
Audi Toilet 1.0 4.48 P-area 1.80 8.06
Drg Title : 2025-09-18_GVM_A0-12_SUNK DIAGRAM
Drg Date : 19-09-2025
Male Toilet 1.0 39.03 P-area 0.60 23.42
Female toilet 1.0 31.75 P-area 0.60 19.05
Drg Title : 2025-09-18_GVM_A0-12_SUNK DIAGRAM
Drg Date : 19-09-2025
Female toilet 1.0 8.23 P-area 0.60 4.94
Male toilet 1.0 17.57 P-area 0.60 10.54
Terrace 1.0 26.12 P-area 0.60 15.67
5 FLOORING WORK
5.1 MANDANA-1 (25MM THICK GRANITE) FLOORING CODE-A12-04 & 1/A14-01
Ground Level Plan
(Location : 7.2m Wide Public Corridor,lobby,entrance lobby,First Aid)
Drg Title : GVM_A4_DETAILED PLAN
Drg Date : 11-09-2025
7.2m Wide Corridor 9 (till Grid X3) 1.0 1000.41 P-area 1000.41
Ded Of Columns -3.0 0.56 P-area -1.68
Lobby 1.0 155.63 P-area 155.63
First Aid 1.0 11.00 P-area 11.00
Lobby Near Audi 1.0 27.67 P-area 27.67
(Location : 7.2m Wide Public Corridor,lobby,entrance lobby,First Aid)
Drg Title : GVM_A4_DETAILED PLAN
Drg Date : 11-09-2025
Lobby 1.0 194.45 P-area 194.45
Add door sill 1.0 3.25 1.00 3.25
(Location : lobby)
Drg Title : GVM_A4_DETAILED PLAN
Drg Date : 11-09-2025
Lobby 1.0 38.91 P-area 38.91
5.2 T.W WOOD PLANKS 25MM (SOLID WOOD FLOOR) CODE-A12-04 & 6/A14-01
Ground Level Plan
(Location : Multipurpose Hall)
Drg Title : GVM_A4_DETAILED PLAN
Drg Date : 11-09-2025
Multipurpose Hall 1.0 159.21 P-area 159.21
5.3 VDF CONCERETE FLOORING CODE-A12-04 & 2/A14-02
GROUND LEVEL PLAN
(Location : Bhasa Gallery)
Drg Title : GVM_A4_DETAILED PLAN
Drg Date : 11-09-2025
Bhasa gallery 1.0 196.93 P-area 196.93
(Location : BOUNTIFUL GUJARAT,GAURAV GALLERY,)
Drg Title : GVM_A4_DETAILED PLAN
Drg Date : 11-09-2025
Bountiful Gujarat 1.0 641.85 P-area 641.85
Gaurav gallery 1.0 456.55 P-area 456.55
Gaurav gallery 1.0 617.32 P-area 617.32
5.5 25MM THICK STEEL GREY GRANITE FLOORING CODE-A12-04 & 1/A14-01
Ground Floor Level Plan
(Location : Female Toilet, Male Toilet)
Drg Title : GVM_A4_DETAILED PLAN
Drg Date : 11-09-2025
Male Toilet 1.0 41.28 P-area 41.28
Female Toilet 1.0 31.77 P-area 31.77
Male Toilet 1.0 32.49 P-area 32.49
Female Toilet 1.0 25.53 P-area 25.53
1st Floor Level Plan
(Location : Female Toilet, Male Toilet,J.C)
Drg Title : GVM_A4_DETAILED PLAN
Drg Date : 11-09-2025
Male Toilet 1.0 39.03 P-area 39.03
Female Toilet 1.0 31.75 P-area 31.75
2nd Floor Level Plan
(Location : Female Toilet, Male Toilet,director toilet)
Drg Title : GVM_A4_DETAILED PLAN
Drg Date : 11-09-2025
Male Toilet 1.0 17.57 P-area 17.57
Female Toilet 1.0 8.23 P-area 8.23
Director Toilet 1.0 2.00 1.36 2.72
5.6 WOODEN DECK CODE-A12-04 & 12/A14-01
2nd Floor Level Plan
Drg Title : GVM_A4_DETAILED PLAN
Drg Date : 11-09-2025
OTS Break down 1.0 23.43 P-area 23.43
5.7 MANDANA-2 (25MM THICK GRANITE) FLOORING CODE-A12-04 & 1/A14-01
Ground Floor Level Plan
(Location : Restaurant indoor)
Drg Title : GVM_A4_DETAILED PLAN
Drg Date : 11-09-2025
Restaurant Indoor 1.0 269.93 P-area 269.93
5.8 RUBBER TILE FLOORING CODE-A12-04 & 3/A14-01
Ground Floor Level Plan
(Location : baby Feeding)
Drg Title : GVM_A4_DETAILED PLAN
Drg Date : 11-09-2025
Baby Feeding 1.0 3.55 2.68 9.51
5.9 S.S WALK OF MATT CODE-A12-04 & 8/A14-01
Lower Floor Level Plan
(Location : baby Feeding)
Drg Title : GVM_A4_DETAILED PLAN
Drg Date : 11-09-2025
Baby Feeding 1.0 1.62 p-area 1.62
Ground Floor Level Plan
(Location : baby Feeding)
Drg Title : GVM_A4_DETAILED PLAN
Drg Date : 11-09-2025
Baby Feeding 1.0 28.89 p-area 28.89
6.1 SANDSTONE CLADDING DRG CODE- A12-05 REF : 4/A14-02
Drg Title : FINISHES DIAGRAM-INT WALLS
Drg No : A12-05
Drg Date : 25-09-2025
Auditorium Lobby 1.0 14.05 3.00 42.15
RESTAURANT INDOOR (A6-06 1) 1.0 13.00 4.20 54.60
RESTAURANT INDOOR (A6-06 3) 1.0 7.20 4.20 30.24
7.2m wide corridor 1.0 51.22 4.20 215.12
Ded Of glazing -1.0 24.19 1.46 -35.20
Entrance lobby (A06-07 2) 1.0 13.60 6.00 81.57
Drg Title : FINISHES DIAGRAM-INT WALLS
Drg No : A12-05
Drg Date : 25-09-2025
Entrance lobby (A06-07 2) 1.0 15.70 1.60 25.12
6.2 FIRE RATED GYPSUM BOARD + PAINT (NAILABLE PLYWOOD SUBSTRATE) DRG CODE- A12-05 REF : 17/A14-02
Drg Title : FINISHES DIAGRAM-INT WALLS
Drg No : A12-05
Drg Date : 25-09-2025
MULTIPURPOSE HALL 1.0 56.75 3.90 221.33
BHASHA GALLERY 1.0 73.20 3.90 285.48
Drg Title : FINISHES DIAGRAM-INT WALLS
Drg No : A12-05
Drg Date : 25-09-2025
BOUNTIFUL GUJARAT 1.0 133.95 p-line 4.80 642.96
on column 2.0 2.67 p-line 4.80 25.63
GAURAV GALLERY 1.0 95.15 4.80 456.72
on columns 2.0 2.67 p-line 4.80 25.63
GAURAV GALLERY 1.0 122.01 4.80 585.65
6.3 WOODEN PANELING DRG CODE- A12-05 REF : 7/A14-02
Drg Title : FINISHES DIAGRAM-INT WALLS
Drg No : A12-05
Drg Date : 25-09-2025
AUDITORIUM (A9-03 SEC 05) 1.0 22.95 4.00 91.80
RESTAURANT INDOOR 1.0 26.78 4.20 112.46
Drg Title : FINISHES DIAGRAM-INT WALLS
Drg No : A12-05
Drg Date : 25-09-2025
Lobby near gaurav gallery 1.0 7.80 4.20 32.76
6.4 MANDANA STONE-3 CLADDING DRG CODE- A12-05 REF : 6/A14-02
Drg Title : FINISHES DIAGRAM-INT WALLS
Drg No : A12-05
Drg Date : 25-09-2025
RESTAURANT INDOOR (A6-06 8) 1.0 16.45 4.20 69.07
RESTAURANT INDOOR (A6-06 7) 1.0 2.03 4.20 8.53
RESTAURANT INDOOR (A6-06 6) 1.0 1.96 1.80 3.52
RESTAURANT INDOOR (A6-06 5) 1.0 3.77 4.20 15.83
RESTAURANT INDOOR (A6-06 4) 1.0 3.30 4.20 13.86
7.2m public corridor (A6-04) 1.0 73.38 4.20 308.19
Ded of Fixed glass -1.0 0.60 2.40 -1.44
Drg Title : FINISHES DIAGRAM-INT WALLS
Drg No : A12-05
Drg Date : 25-09-2025
Toilet entry 1.0 5.04 4.80 24.19
Lobby near gaurav gallery
6.5 GRANITE CLADDING DRG CODE- A12-05 REF : 6/A14-02
Lower Ground Floor
Drg Title : FINISHES DIAGRAM-INT WALLS
Drg No : A12-05
Drg Date : 25-09-2025
Ded Of Lift opn -2.0 1.10 2.10 -4.62
Ded of Shaft opn DS-B-L-01 -1.0 0.90 1.50 -1.35
Mezzanine Floor
Drg Title : FINISHES DIAGRAM-INT WALLS
Drg No : A12-05
Drg Date : 25-09-2025
Ded Of Lift opn -2.0 1.10 2.10 -4.62
Ded of Shaft opn DS-B-L-01 -1.0 0.90 1.50 -1.35
Drg Title : FINISHES DIAGRAM-INT WALLS
Drg No : A12-05
Drg Date : 25-09-2025
Ded Of Lift opn -2.0 1.10 2.10 -4.62
Ded of Shaft opn DS-B-G-02 -1.0 0.90 1.50 -1.35
Drg Title : FINISHES DIAGRAM-INT WALLS
Drg No : A12-05
Drg Date : 25-09-2025
Ded Of Lift opn -2.0 1.10 2.10 -4.62
Ded of Shaft opn DS-B-G-02 -1.0 0.90 1.50 -1.35
Drg Title : FINISHES DIAGRAM-INT WALLS
Drg No : A12-05
Drg Date : 25-09-2025
Ded Of Lift opn -2.0 1.10 2.10 -4.62
6.7 VITRIFIED TILES CLADDING DRG CODE- A12-05 REF : 8/A14-02
Drg Title : FINISHES DIAGRAM-INT WALLS
Drg No : A12-05
Drg Date : 25-09-2025
Female Toilet 1.0 30.32 3.00 90.95
Baby Feeding 2.0 3.55 3.00 21.27
Male Toilet 1.0 48.03 3.00 144.09
Janitor Room 2.0 2.02 3.00 12.12
Male Toilet 1.0 33.98 3.00 101.94
Janitor room 2.0 2.10 3.00 12.60
Female Toilet 1.0 27.46 3.00 82.37
Drg Title : FINISHES DIAGRAM-INT WALLS
Drg No : A12-05
Drg Date : 25-09-2025
Female Toilet 1.0 30.32 3.00 90.95
Male Toilet 1.0 41.99 3.00 125.97
Janitor Room 2.0 2.45 3.00 14.70
Drg Title : FINISHES DIAGRAM-INT WALLS
Drg No : A12-05
Drg Date : 25-09-2025
Female Toilet 1.0 12.80 2.70 34.56
Male Toilet 1.0 22.25 2.70 60.08
Director toilet 2.0 2.20 3.00 13.20
6.9 VENEER CLADDING DRG CODE- A12-05 REF : 16/A14-02
Drg Title : FINISHES DIAGRAM-INT WALLS
Drg No : A12-05
Drg Date : 25-09-2025
Column cladding 3.0 3.61 4.20 45.51
8 FALSE CEILING WORK
8.1 PUNCHED GYPSUM + ACOUSTIC LINING CODE-A12-07 & 3/A14-04
LOWER GROUND LEVEL PLAN
(Location : Exhibits & Collection,Service Shipping rec,Metering Kisok,Waste Management,UPS Bank,Sec lockers,Collection storage)
Drg Title : GVM_A12_07_Int Ceiling Diagram
Drg Date : 18-09-2025
Exhibits & Collection 1.0 102.14 P-area 102.14
Ded Of Column -1.0 0.75 0.75 -0.56
Service Shipping receiving 1.0 38.55 P-area 38.55
Metering Kisok 1.0 33.73 P-area 33.73
Waste Management 1.0 21.66 P-area 21.66
UPS Bank 1.0 32.91 P-area 32.91
Security Ready lockers 1.0 37.62 P-area 37.62
Collection storage 1.0 107.05 P-area 107.05
8.3 GYPSUM + ACOUSTIC LINING CODE-A12-07 & 1/A14-04
GROUND FLOOR LEVEL PLAN
(Location : Outdoor Restaurant,Lobby,7.2m Public Corridor,multipurpose hall)
Drg Title : GVM_A12_07_Int Ceiling Diagram
Drg Date : 18-09-2025
Outdoor Restaurant 1.0 96.62 P-area 96.62
7.2m Wide Passage 1.0 327.05 P-area 327.05
Ded OF columns -3.0 0.56 P-area -1.68
Lobby 1.0 155.63 P-area 155.63
Lobby 1.0 11.59 P-area 11.59
Multipurpose Hall 1.0 159.21 P-area 159.21
1st FLOOR LEVEL PLAN
(Location : Lobby)
Drg Title : GVM_A12_07_Int Ceiling Diagram
Drg Date : 18-09-2025
Lobby 1.0 215.96 P-area 215.96
8.4 (AUDI) GYPSUM + ACOUSTIC CODE-A12-07 & 2A/A14-04
GROUND FLOOR LEVEL PLAN
(Location : Auditorium)
Drg Title : GVM_A12_07_Int Ceiling Diagram
Drg Date : 18-09-2025
Auditorium 1.0 266.40 P-area 266.40
8.5 WOODEN CEILING CODE-A12-07 & 9/A14-04
GROUND FLOOR LEVEL PLAN
(Location : Indoor restaurant,Multipurpose Hall)
Drg Title : GVM_A12_07_Int Ceiling Diagram
Drg Date : 18-09-2025
Indoor restaurant 1.0 269.93 P-area 269.93
Ded Of Wooden Slats Area -1.0 94.34 P-area -94.34
1st FLOOR LEVEL PLAN
(Location : Lobby)
Drg Title : GVM_A12_07_Int Ceiling Diagram
Drg Date : 18-09-2025
Lobby 1.0 36.00 P-area 36.00
8.6 WOODEN SLATS CODE-A12-07 & 10/A14-04
GROUND FLOOR LEVEL PLAN
(Location : Indoor restaurant)
Drg Title : GVM_A12_07_Int Ceiling Diagram
Drg Date : 18-09-2025
Indooe Restaurant 1.0 94.34 P-area 94.34
5 FLOORING WORK
5.9 25MM THICK KOTA STONE FLOORING CODE-A12-04 & 4/A14-01
Lower Ground Level Plan
(Location : Gas bank,Exhivits Collection,Transit Store,Metering kisok,Waste Management,Chillar room,Staff break down,ups bank,moving stool storage,shipping,service shipping receiving,q room,av store,collecction storage)
Drg Title : GVM_A4_DETAILED PLAN
Drg Date : 11-09-2025
Exhibits Collection 1.0 102.14 P-area 102.14
Ded Of Column -1.0 0.75 0.75 -0.56
Transit Store 1.0 89.88 P-area 89.88
Loading Ramp 1.0 10.00 1.20 12.00
Metering kisok 1.0 33.73 P-area 33.73
Waste management 1.0 21.66 P-area 21.66
Waste management 1.0 3.05 2.33 7.11
UPS Bank 1.0 32.91 P-area 32.91
Staff Break Room 1.0 7.45 6.52 48.57
Chillar Room 1.0 294.68 P-area 294.68
Ded Of Column -1.0 0.75 0.75 -0.56
Ded Of Column -1.0 1.00 0.75 -0.75
Ded Of Column -1.0 0.75 0.50 -0.38
Service Shipping Receiving 1.0 38.55 P-area 38.55
Shipping 1.0 37.03 P-area 37.03
Crate Storage 1.0 31.49 P-area 31.49
Moving Stool Storage 1.0 36.61 P-area 36.61
Sec Ready Lockers 1.0 37.62 P-area 37.62
Plinth & Panel 1.0 102.74 P-area 102.74
Ded Of Column -2.0 0.75 0.75 -1.13
Collection Storage 1.0 107.05 P-area 107.05
North - South Passage 1.0 1370.08 P-area 1370.08
Ded Of Block -1.0 473.34 P-area -473.34
Ded PF Column -9.0 0.75 0.75 -5.06
Mezzanine Level Plan
(Location : Mezzanine Passage,Elec Room,BMS Rm,AHU,Housekeeping Store)
Drg Title : GVM_A4_DETAILED PLAN
Drg Date : 11-09-2025
Mezzanine Passage 1.0 133.81 P-area 133.81
Ded OF Column -1.0 0.47 P-area -0.47
Housekeeping Centre 1.0 37.10 P-area 37.10
Ground Floor Level Plan
(Location : Kitchen,AHU,3.4 m Wide Passage,Folding Furniture Store,Shaft,Controm Rm,AHU)
Drg Title : GVM_A4_DETAILED PLAN
Drg Date : 11-09-2025
Kitchen 1.0 212.34 P-area 212.34
Ded Of Wall -1.0 4.87 P-area -4.87
Ded Of Wall -1.0 3.55 P-area -3.55
Ded OF Columns -1.0 0.75 0.75 -0.56
3.4 m Wide Passage 1.0 223.65 P-area 223.65
Folding Furniture Store 1.0 21.27 P-area 21.27
Shaft 1.0 2.87 P-area 2.87
Control Rm 1.0 7.10 4.35 30.89
AHU 1.0 31.59 P-area 31.59
Shaft At Staircase 1.0 0.90 0.82 0.73
Shaft At Staircase 1.0 0.90 0.80 0.72
Green Rm 1.0 107.70 P-area 107.70
1ST Floor Level Plan
(Location : AHU,3.4M SERVICE PASSAGE,SHAFT)
Drg Title : GVM_A4_DETAILED PLAN
Drg Date : 11-09-2025
AHU 1.0 30.80 P-area 30.80
3.4m Service Passage 1.0 216.26 P-area 216.26
AHU 1.0 37.67 P-area 37.67
Shaft 1.0 4.29 P-area 4.29
ST-A1 Shaft 1.0 0.95 P-area 0.95
AHU 1.0 35.91 P-area 35.91
2nd Floor Level Plan
(Location : AHU,Pantry,file Rm,shaft)
Drg Title : GVM_A4_DETAILED PLAN
Drg Date : 11-09-2025
AHU 1.0 19.18 P-area 19.18
Pantry 1.0 6.56 P-area 6.56
File Rm 1.0 7.90 P-area 7.90
5.10 SEALED CONCRETE FLOORING CODE-A12-04 & 13A/A14-01
Lower Ground Floor
(Location : ELEV-E-05,ELEV-E-04,SHAFT)
Drg Title : GVM_A4_DETAILED PLAN
Drg Date : 11-09-2025
Loading Bay 1.0 105.81 P-area 105.81
Shaft 1.0 6.23 P-area 6.23
Duct at Chillar Rm 1.0 1.54 0.83 1.28
Ground Floor Level plan
(Location : ELEV-A1)
Drg Title : GVM_A4_DETAILED PLAN
Drg Date : 11-09-2025
5.11 G.I WALK OF MATT CODE-A12-04 & 8/A14-01
Lower Floor Level Plan
(Location : ST-C1,service entry)
Drg Title : GVM_A4_DETAILED PLAN
Drg Date : 11-09-2025
Ground Floor Level Plan
Drg Title : GVM_A4_DETAILED PLAN
Drg Date : 11-09-2025
Green Room 1.0 5.40 P-area 5.40
2nd Floor Level Plan
(Location : Lobby,ots break garden)
Drg Title : GVM_A4_DETAILED PLAN
Drg Date : 11-09-2025
Lobby 1.0 5.40 P-area 5.40
OTS Break Garden 1.0 3.85 P-area 3.85
5.12 GRATING CODE-A12-04 & 7/A14-01
Mezzanine Level Plan
(Location : SHAFTS)
Drg Title : GVM_A4_DETAILED PLAN
Drg Date : 11-09-2025
Shaft 1.0 3.60 P-area 3.60
Ground Floor Level Plan
(Location : SHAFTS)
Drg Title : GVM_A4_DETAILED PLAN
Drg Date : 11-09-2025
Shaft 1.0 3.60 P-area 3.60
1st Floor Level Plan
(Location : SHAFTS)
Drg Title : GVM_A4_DETAILED PLAN
Drg Date : 11-09-2025
Shaft 1.0 3.92 P-area 3.92
2nd Floor Level Plan
(Location : SHAFTS)
Drg Title : GVM_A4_DETAILED PLAN
Drg Date : 11-09-2025
Shaft 1.0 3.92 P-area 3.92
5.13 8MM THICK WHITE GLAZED TILES CODE-A12-04 & 11/A14-01
2nd Floor Level Plan
(Location : SHAFTS)
Drg Title : GVM_A4_DETAILED PLAN
Drg Date : 11-09-2025
Domestic tank 1.0 4.15 2.44 10.13
5.14 10 MM THICK VITRIFIED TILES FLOORING CODE-A12-04 & 8/A14-01
Lower Ground Level Plan
(Location : Male Toilet,Female Toilet,Storage)
Drg Title : GVM_A4_DETAILED PLAN
Drg Date : 11-09-2025
Male Toilet 1.0 17.70 P-area 17.70
Female Toilet 1.0 18.89 P-area 18.89
First Aid 1.0 8.03 P-area 8.03
Mezzanine Level Plan
(Location : Male Toilet,Female Toilet,Male Staff room,Female Staff Room)
Drg Title : GVM_A4_DETAILED PLAN
Drg Date : 11-09-2025
Staff Toilet-Female 1.0 18.88 P-area 18.88
Staff Toilet-Male 1.0 17.71 P-area 17.71
Male Staff Room 1.0 21.05 P-area 21.05
Female Staff Room 1.0 14.58 P-area 14.58
Ground Level Plan
(Location : Kitchen Staff Changing room)
Drg Title : GVM_A4_DETAILED PLAN
Drg Date : 11-09-2025
Kitchen Staff Changing Room 1.0 3.27 3.03 9.91
Audi toilet 1.0 3.39 P-area 3.39
5.15 RAISED ANTI-STATIC FLOORING CODE-A12-04 & 9/A14-01
Lower Ground Level Plan
(Location : Sec.Monitor,Server Room,IT Work Room)
Drg Title : GVM_A4_DETAILED PLAN
Drg Date : 11-09-2025
Sec.Monitor 1.0 35.73 P-area 35.73
Server Rm 1.0 42.91 P-area 42.91
Ded Of Column -1.0 1.00 0.75 -0.75
Ded Of Column -1.0 0.75 0.50 -0.38
IT Work Room 1.0 53.59 P-area 53.59
Ded Of Column -2.0 0.75 0.75 -1.13
AV Store 1.0 50.30 P-area 50.30
Ded Of Column -1.0 0.75 0.75 -0.56
5.16 NYLON MATT FLOORING CODE-A12-04 & 10/A14-01
Ground Floor Level plan
(Location : Stage Audi)
Drg Title : GVM_A4_DETAILED PLAN
Drg Date : 11-09-2025
Stage Auditorium 1.0 266.40 P-area 266.40
(Location : reception,confrence,file room,meerting Rm,Working Rm,Bm,workstation,Director,acc Section)
Drg Title : GVM_A4_DETAILED PLAN
Drg Date : 11-09-2025
Reception 1.0 182.19 P-area 182.19
File Rm -1.0 13.33 P-area -13.33
Docent Lounge 1.0 18.90 P-area 18.90
Confrence 1.0 64.51 P-area 64.51
Curatorial 1.0 11.49 P-area 11.49
Senior Admin 1.0 11.70 P-area 11.70
Meeting Rm 1.0 14.02 P-area 14.02
Director 1.0 18.01 P-area 18.01
5.18 25 MM THICK GRAY GRANITE FLOORING CODE-A12-04 & 1/A14-01
Lower Ground Level Plan
(Location : Quarntine rm)
Drg Title : GVM_A4_DETAILED PLAN
Drg Date : 11-09-2025
Quarantine Room 1.0 61.45 P-area 61.45
Ded Of Column -1.0 0.48 P-area -0.48
5.20 25MM THICK KOTA STONE FLOORING CODE-A12-04 & 4/A14-01 (LOCATION : Staircase)
Lower Ground Level Plan As per A7_staricase & ramp details
(Location : Stairacse)
Drg Title : GVM_A4_DETAILED PLAN
Drg Date : 11-09-2025
Floor Landing-01 (-9900mm) 1.0 3.60 P-area 3.60
Floor Landing-02 (-9000mm) 1.0 4.50 P-area 4.50
Mid-landing-4 (-7200mm) 1.0 14.10 P-area 14.10
Mid-landing-5 (-5400mm) 1.0 9.33 P-area 9.33
Mid-landing-6 (-3600mm) 1.0 11.61 P-area 11.61
Mid-landing-7 (-1800mm) 1.0 9.33 P-area 9.33
Floor Landing-01 (-8400mm) 1.0 9.07 P-area 9.07
Mid-landing-2 (-6600mm) 1.0 8.90 P-area 8.90
Mezzanine Level Plan As per A7_staricase & ramp details
(Location : Stairacse)
Drg Title : GVM_A4_DETAILED PLAN
Drg Date : 11-09-2025
Floor Landing-01 (-4800mm) 1.0 39.92 P-area 39.92
Mid Landing-02 (-3600mm) 1.0 8.88 P-area 8.88
Mid Landing-03 (-1800mm) 1.0 10.10 P-area 10.10
Floor Landing-03 (-4800mm) 1.0 13.53 P-area 13.53
Mid-landing-4 (-3000mm) 1.0 8.90 P-area 8.90
Mid-landing-4 (-1500mm) 1.0 10.10 P-area 10.10
Ground Level Plan As per A7_staricase & ramp details
(Location : Stairacse)
Drg Title : GVM_A4_DETAILED PLAN
Drg Date : 11-09-2025
Floor Landing-01 (0mm) 1.0 12.24 P-area 12.24
Mid-landing-9 (+1500mm) 1.0 11.82 P-area 11.82
Mid-landing-10 (+3000mm) 1.0 12.24 P-area 12.24
Mid-landing-11 (+4500mm) 1.0 11.82 P-area 11.82
Floor Landing-06 (0mm) 1.0 11.12 P-area 11.12
Mid Landing-07 (+1500 mm) 1.0 11.30 P-area 11.30
Mid Landing-08 (+3000mm) 1.0 8.90 P-area 8.90
Floor Landing-09 (+4500mm) 1.0 10.10 P-area 10.10
Floor Landing-04 (00mm) 1.0 10.82 P-area 10.82
Mid Landing-05 (+1500 mm) 1.0 10.10 P-area 10.10
Mid Landing-06 (+3000 mm) 1.0 10.10 P-area 10.10
Mid Landing-07 (+4500 mm) 1.0 8.90 P-area 8.90
1st Level Plan As per A7_staricase & ramp details
(Location : Stairacse)
Drg Title : GVM_A4_DETAILED PLAN
Drg Date : 11-09-2025
Floor Landing-01 (8000mm) 1.0 12.24 P-area 12.24
Floor Landing-10 (+6000mm) 1.0 11.40 P-area 11.40
Mid Landing-11 (+7800 mm) 1.0 10.10 P-area 10.10
Mid Landing-12 (+9600mm) 1.0 8.90 P-area 8.90
Floor Landing-13 (+11400mm) 1.0 8.90 P-area 8.90
Floor Landing-14 (+13350mm) 1.0
Floor Landing-08 (+6000mm) 1.0 12.02 P-area 12.02
Mid Landing-09 (+7800 mm) 1.0 8.90 P-area 8.90
Mid Landing-10 (+9600 mm) 1.0 8.90 P-area 8.90
Mid Landing-11 (+11400 mm) 1.0 8.90 P-area 8.90
2nd Level Plan As per A7_staricase & ramp details
(Location : Stairacse)
Drg Title : GVM_A4_DETAILED PLAN
Drg Date : 11-09-2025
Floor Landing-14 (+13350mm) 1.0 11.43 P-area 11.43
Floor Landing-12 (+13350mm) 1.0 9.66 P-area 9.66
5.21 25MM THICK KOTA STONE-TREADS CODE-A12-04 & 4/A14-01 (LOCATION : Staircase)
Lower Ground Level Plan
(Location : Stairacse)
Drg Title : GVM_A4_DETAILED PLAN
Drg Date : 11-09-2025
Mezzanine Level Plan As per A7_staricase & ramp details
(Location : Stairacse)
Drg Title : GVM_A4_DETAILED PLAN
Drg Date : 11-09-2025
Ground Level Plan As per A7_staricase & ramp details
(Location : Stairacse)
Drg Title : GVM_A4_DETAILED PLAN
Drg Date : 11-09-2025
1st Level Plan As per A7_staricase & ramp details
(Location : Stairacse)
Drg Title : GVM_A4_DETAILED PLAN
Drg Date : 11-09-2025
5.22 25MM THICK KOTA STONE-RISERS CODE-A12-04 & 4/A14-01 (LOCATION : Staircase)
Lower Ground Level Plan
(Location : Stairacse)
Drg Title : GVM_A4_DETAILED PLAN
Drg Date : 11-09-2025
Mezzanine Level Plan As per A7_staricase & ramp details
(Location : Stairacse)
Drg Title : GVM_A4_DETAILED PLAN
Drg Date : 11-09-2025
Ground Level Plan As per A7_staricase & ramp details
(Location : Stairacse)
Drg Title : GVM_A4_DETAILED PLAN
Drg Date : 11-09-2025
1st Level Plan As per A7_staricase & ramp details
(Location : Stairacse)
Drg Title : GVM_A4_DETAILED PLAN
Drg Date : 11-09-2025
6 INTERNAL WALL FINISH WORK (BOH)
6.10 VITRIFIED TILES-2 CLADDING DRG CODE- A12-05 REF : 8/A14-02
Lower Ground Floor
Drg Title : FINISHES DIAGRAM-INT WALLS
Drg No : A12-05
Drg Date : 25-09-2025
Male Staff Toilet 1.0 23.44 2.70 63.27
Female Staff Toilet 1.0 23.21 2.70 62.68
Mezzanine Floor
Drg Title : FINISHES DIAGRAM-INT WALLS
Drg No : A12-05
Drg Date : 25-09-2025
STAFF TOILET - MALE 1.0 23.46 2.70 63.34
STAFF TOILET - FEMALE 1.0 23.18 2.70 62.59
FEMALE STAFF LOCKER RM 1.0 15.45 2.70 41.70
MALE STAFF LOCKER RM 1.0 20.58 2.70 55.57
Drg Title : FINISHES DIAGRAM-INT WALLS
Drg No : A12-05 Floor HT = 3.00
Drg Date : 25-09-2025
Grenn Room Toilet (A9-01) 1.0 80.38 P-line 3.00 241.14
Grenn Room Toilet 1.0 8.76 P-line 3.00 26.28
6.11 GYPSUM PLASTER + PAINT DRG CODE- A12-05 REF : 10/A14-02
Lower Ground Floor
Drg Title : FINISHES DIAGRAM-INT WALLS
Drg No : A12-05
Drg Date : 25-09-2025
Service Shipping Receiving (a9-10) 1.0 25.74 P-line 3.60 92.66
Shipping/ Receiving security 1.0 26.73 3.60 96.21
Create Storage 1.0 24.48 3.60 88.11
Moving Tool Storage 1.0 26.84 3.60 96.62
Security Ready Lockers 1.0 27.22 3.60 97.97
EXHIBITS & COLLECTION 1.0 41.79 3.60 150.44
Transit Store 1.0 39.40 3.60 141.84
Metering kisok 1.0 27.64 2.70 74.63
Waste Management 1.0 22.21 2.70 59.96
Waste Management 2.0 3.05 2.70 16.47
Industrial First Ad 1.0 11.49 2.70 31.02
Security Monitor 1.0 25.27 2.70 68.23
QUARANTINE+CONSERVE+EXAMINE LAB 1.0 35.53 2.70 95.93
PLINTH & PANEL 1.0 40.66 3.60 146.38
Collection storage 1.0 45.64 3.60 164.29
STAFF BREAK RM 2.0 4.75 2.70 25.65
D-J-L-02 Servic entry -1.0 2.70 3.00 -8.10
Middle passage block 1.0 96.80 3.60 348.47
Mezzanine Floor
Drg Title : FINISHES DIAGRAM-INT WALLS
Drg No : A12-05
Drg Date : 25-09-2025
Electric Room 2.0 5.67 2.70 30.62
HOUSEKEEPING CENTRE 1.0 30.15 2.70 81.41
MEZZANINE PASSAGE 1.0 114.03 2.70 307.87
less security cladding -1.0 12.46 2.70 -33.63
less lift cadding -1.0 9.93 2.70 -26.80
Mezzanine Outer Wall 1.0 75.28 4.80 361.36
Drg Title : FINISHES DIAGRAM-INT WALLS
Drg No : A12-05
Drg Date : 25-09-2025
Kithcen staff changing room 2.0 3.27 4.00 26.16
less lift cladding -1.0 20.22 3.00 -60.65
Control rm 2.0 7.10 3.00 42.60
Folding furniture store 1.0 19.40 3.00 58.20
Drg Title : FINISHES DIAGRAM-INT WALLS
Drg No : A12-05
Drg Date : 25-09-2025
less lift cladding -1.0 20.22 3.60 -72.77
Drg Title : FINISHES DIAGRAM-INT WALLS
Drg No : A12-05
Drg Date : 25-09-2025
Ded Of lift Cladding -1.0 8.18 3.00 -24.53
Workstation 1.0 105.26 3.00 315.77
6.12 GYPSUM PARTITION WALL SYSTEM DRG CODE- A12-05 REF : 9/A14-02 (100 MM THICK DRY WALL PARTITION)
Drg Title : FINISHES DIAGRAM-INT WALLS
Drg No : A12-05
Drg Date : 25-09-2025
Conference 1.0 9.84 3.00 29.51
Building management 5.0 3.45 3.00 51.75
Senior admin 2.0 3.29 3.00 19.74
6.13 SOUND ATTENAUTION DRG CODE- A12-05 REF : 11/A14-02
Lower Ground Floor
Drg Title : FINISHES DIAGRAM-INT WALLS
Drg No : A12-05
Drg Date : 25-09-2025
Chiller room (Sec-A9-02 Sec-04 & Sec-A9-06 Sec-08) 1.0 4.65 4.40 20.46
Mezzanine Floor
Drg Title : FINISHES DIAGRAM-INT WALLS
Drg No : A12-05
Drg Date : 25-09-2025
on column 1.0 3.46 Pline 4.50 15.55
Drg Title : FINISHES DIAGRAM-INT WALLS
Drg No : A12-05
Drg Date : 25-09-2025
Drg Title : FINISHES DIAGRAM-INT WALLS
Drg No : A12-05
Drg Date : 25-09-2025
Drg Title : FINISHES DIAGRAM-INT WALLS
Drg No : A12-05
Drg Date : 25-09-2025
6.14 WHITE GLAZED VITRIFIED TILES CLADDING DRG CODE- A12-05 REF : 8/A14-02
Mezzanine Floor
Drg Title : FINISHES DIAGRAM-INT WALLS
Drg No : A12-05
Drg Date : 25-09-2025
Security office 1.0 12.46 2.70 33.63
Drg Title : FINISHES DIAGRAM-INT WALLS
Drg No : A12-05
Drg Date : 25-09-2025
Fire Fighting tank 1.0 18.02 2.40 43.25
Domestic tank 1.0 18.02 2.40 43.25
6.15 PLASTER + PAINT DRG CODE- A12-05 REF : 14/A14-02
Lower Ground Floor
Drg Title : FINISHES DIAGRAM-INT WALLS
Drg No : A12-05
Drg Date : 25-09-2025
LOADING/UNLOADING BAY (A9-10 sec 13) 1.0 48.08 AVG 9.05 435.14
6.16 PLASTER FINISH DRG CODE- A12-05 REF : 15/A14-02
Lower Ground Floor
Drg Title : FINISHES DIAGRAM-INT WALLS
Drg No : A12-05
Drg Date : 25-09-2025
Fire fighting shaft 2.0 1.53 3.60 11.02
Mezzanine Floor
Drg Title : FINISHES DIAGRAM-INT WALLS
Drg No : A12-05
Drg Date : 25-09-2025
Drg Title : FINISHES DIAGRAM-INT WALLS Floor HT = 6.00
Drg No : A12-05
Drg Date : 25-09-2025
Kitchen shaft 2.0 4.37 6.00 52.46
Less lift opn -1.0 1.20 2.50 -3.00
Drg Title : FINISHES DIAGRAM-INT WALLS Floor HT = 7.20
Drg No : A12-05
Drg Date : 25-09-2025
ST-C1 FF SHAFT 1.0 5.50 p-line 7.20 39.60
Kitchen shaft 2.0 4.37 7.20 62.96
SHAFT 1.0 10.37 p-line 7.20 74.63
SHAFT 1.0 10.79 p-line 7.20 77.69
Less lift opn -1.0 1.20 2.50 -3.00
Drg Title : FINISHES DIAGRAM-INT WALLS Floor HT = 4.80
Drg No : A12-05
Drg Date : 25-09-2025
SHAFT 1.0 10.37 p-line 4.80 49.75
6 SKIRTING WORK
6.1 WOODEN SKIRTING CODE-A12-06 & 3/A14-03
GROUND LEVEL PLAN
(Location : Multipurpose Hall,audi,Bhasa gallery)
Drg Title : GVM_A12_07_Int Ceiling Diagram
Drg Date : 18-09-2025
Multipurpose Hall 1.0 56.75 P-Line 56.75
Bhasha Gallery 1.0 73.20 0.00
Auditorium 1.0 70.76 70.76
Auditorium 1.0 22.95 22.95
Passage Outside Audi 1.0 14.05 14.05
(Location : Bountiful Gujarat,Gaurav gallery)
Drg Title : GVM_A12_07_Int Ceiling Diagram
Drg Date : 18-09-2025
Bountiful Gujarat 1.0 140.83 140.83
On Column 2.0 3.61 7.22
Gaurav Gallery 1.0 105.10 0.00
On Column 2.0 3.61 0.00
Gaurav Gallery 1.0 131.81 0.00
2nd Floor LEVEL PLAN
(Location : Workstations)
Drg Title : GVM_A12_07_Int Ceiling Diagram
Drg Date : 18-09-2025
Workstations 1.0 72.74 72.74
6.2 KOTA STONE SKIRTING (LOADING BAY) CODE-A12-06 & 2/A14-03
LOWER GROUND LEVEL PLAN
(Location : Loading bay)
Drg Title : GVM_A12_07_Int Ceiling Diagram
Drg Date : 18-09-2025
Loading bay 1.0 17.05 P-Line 0.10 1.71
6.3 KOTA STONE SKIRTING CODE-A12-06 & 1/A14-03
LOWER GROUND LEVEL PLAN
(Location : Gas bank,Exhibits,Transit Store,metering kisok,wm,Storage,ind first aid,staff Break Rm,Chillar Rm,Server Rm,Security Monitor,Examination Lab,Plinth & Panel,IT Work Rm,AV Store,Service,Shipping,crate storage,Moving Tools Storage,Se Ready Lockers,Collection Storage)
Drg Title : GVM_A12_07_Int Ceiling Diagram
Drg Date : 18-09-2025
Gas bank 1.0 7.30 P-Line 0.10 0.73
Gas bank 1.0 10.75 P-Line 0.10 1.08
Exhibits 1.0 41.79 P-Line 0.10 4.18
Transit Store 1.0 39.40 P-Line 0.10 3.94
Metering kisok 1.0 27.64 P-Line 0.10 2.76
Waste Management 1.0 21.89 P-Line 0.10 2.19
Waste Management 2.0 3.07 0.10 0.61
Ind.First Aid 1.0 11.49 0.10 1.15
Staff Break Rm 2.0 7.45 0.10 1.49
Security Monitor 1.0 25.27 0.10 2.53
Examination Lab 1.0 35.53 0.10 3.55
Plinth & Panel 1.0 40.66 0.10 4.07
Service Shipping 1.0 25.74 0.10 2.57
Crate Storage 1.0 24.48 0.10 2.45
Moving Tools Storage 1.0 26.84 0.10 2.68
Security Ready lockers 1.0 27.22 0.10 2.72
Collection Storage 1.0 45.64 0.10 4.56
Passage North To South 1.0 383.40 0.10 38.34
Ded Of Loading entry -1.0 7.25 0.10 -0.73
Ded OF Lift opn -1.0 2.30 0.10 -0.23
Ded Of Lift Opn -2.0 1.10 0.10 -0.22
Ded OF Lift opn -1.0 1.10 0.10 -0.11
Ded oF lift Opn -1.0 2.80 0.10 -0.28
MEZZANINE LEVEL PLAN
(Location : AHU,Electric Rm,BMS Rm,Mezzanine Passage,Housekeeping Store)
Drg Title : GVM_A12_07_Int Ceiling Diagram
Drg Date : 18-09-2025
Electric Rm 2.0 5.67 0.10 1.13
Housekeeping Store 1.0 30.15 0.10 3.02
Mezzanine Passage 1.0 114.03 0.10 11.40
GROUND LEVEL PLAN
(Location : KITCHEN,3.4M Wide Passage,Kitchen Staff Changign room,AHU,Folding Fu store,First aid,Control Rm)
Drg Title : GVM_A12_07_Int Ceiling Diagram
Drg Date : 18-09-2025
Kitchen Staff Changing Room 2.0 3.27 0.10 0.65
3.4m wide Passage 1.0 146.21 0.10 14.62
Ded Of Lift Opn -1.0 4.98 0.10 -0.50
Ded Of Lift Opn -1.0 8.49 0.10 -0.85
Green Room 1.0 97.81 0.10 9.78
Folding Furniture store 1.0 19.40 0.10 1.94
Control Rm 2.0 7.10 0.10 1.42
(Location :3.4M Wide Passage,AHU, )
Drg Title : GVM_A12_07_Int Ceiling Diagram
Drg Date : 18-09-2025
3.4m Wide Passage 1.0 138.01 0.10 13.80
Ded Of lIft Opn -1.0 8.49 0.10 -0.85
Ded Of lIft Opn -1.0 11.70 0.10 -1.17
(Location : AHU,Lobby,pantry )
Drg Title : GVM_A12_07_Int Ceiling Diagram
Drg Date : 18-09-2025
Ded Of Lift Opn -1.0 8.18 0.10 -0.82
6.4 S.S BASE (COLUMN) CODE-A12-06 & 4/A14-03
(Location : 7.2m public Corridor)
Drg Title : 2025-09-18_GVM_A12-06-FINISH DIAGRAM INTERIOR BASE
Drg Date : 18-09-2025
7.2m public Corridor 3.0 3.61 10.84
5.23 25MM THICK KOTA STONE-SKIRTING CODE-A12-04 & 4/A14-01 (LOCATION : Staircase)
Lower Ground Level Plan As per A7_staricase & ramp details
(Location : Stairacse)
Drg Title : GVM_A4_DETAILED PLAN
Drg Date : 11-09-2025
Floor Landing-01 (-9900mm) 1.0 5.60 P-line 5.60
Floor Landing-02 (-9000mm) 1.0 4.26 4.26
Mid-landing-4 (-7200mm) 1.0 11.25 P-line 11.25
Mid-landing-5 (-5400mm) 1.0 8.95 P-line 8.95
Mid-landing-6 (-3600mm) 1.0 9.72 P-line 9.72
Mid-landing-7 (-1800mm) 1.0 8.95 P-line 8.95
Floor Landing-01 (-8400mm) 1.0 13.30 P-line 13.30
Mid-landing-2 (-6600mm) 1.0 8.75 P-line 8.75
Mezzanine Level Plan As per A7_staricase & ramp details
(Location : Stairacse)
Drg Title : GVM_A4_DETAILED PLAN
Drg Date : 11-09-2025
Floor Landing-01 (-4800mm) 1.0 31.89 P-line 31.89
Mid Landing-02 (-3600mm) 1.0 8.72 P-line 8.72
Mid Landing-03 (-1800mm) 1.0 9.95 P-line 9.95
Floor Landing-03 (-4800mm) 1.0 15.55 P-line 15.55
Mid-landing-4 (-3000mm) 1.0 8.73 P-line 8.73
Mid-landing-5 (-1500mm) 1.0 9.95 P-line 9.95
Ground Level Plan As per A7_staricase & ramp details
(Location : Stairacse)
Drg Title : GVM_A4_DETAILED PLAN
Drg Date : 11-09-2025
Floor Landing-01 (0mm) 1.0 11.46 P-line 11.46
Mid-landing-9 (+1500mm) 1.0 11.52 P-line 11.52
Mid-landing-10 (+3000mm) 1.0 11.46 P-line 11.46
Mid-landing-11 (+4500mm) 1.0 11.52 P-line 11.52
Floor Landing-06 (0mm) 1.0 11.66 P-line 11.66
Mid Landing-07 (+1500 mm) 1.0 11.15 P-line 11.15
Mid Landing-08 (+3000mm) 1.0 8.75 P-line 8.75
Floor Landing-09 (+4500mm) 1.0 9.95 P-line 9.95
Floor Landing-04 (00mm) 1.0 11.26 P-line 11.26
Mid Landing-05 (+1500 mm) 1.0 9.95 P-line 9.95
Mid Landing-06 (+3000 mm) 1.0 9.95 P-line 9.95
Mid Landing-07 (+4500 mm) 1.0 8.75 P-line 8.75
1st Level Plan As per A7_staricase & ramp details
(Location : Stairacse)
Drg Title : GVM_A4_DETAILED PLAN
Drg Date : 11-09-2025
Floor Landing-01 (8000mm) 1.0 11.46 P-line 11.46
Floor Landing-10 (+6000mm) 1.0 11.95 P-line 11.95
Mid Landing-11 (+7800 mm) 1.0 9.95 P-line 9.95
Mid Landing-12 (+9600mm) 1.0 8.75 P-line 8.75
Floor Landing-13 (+11400mm) 1.0 8.75 P-line 8.75
Floor Landing-08 (+6000mm) 1.0 12.46 P-line 12.46
Mid Landing-09 (+7800 mm) 1.0 8.75 P-line 8.75
Mid Landing-10 (+9600 mm) 1.0 8.75 P-line 8.75
Mid Landing-11 (+11400 mm) 1.0 8.75 P-line 8.75
2nd Level Plan As per A7_staricase & ramp details
(Location : Stairacse)
Drg Title : GVM_A4_DETAILED PLAN
Drg Date : 11-09-2025
Floor Landing-14 (+13350mm) 1.0 11.43 P-l 11.43
Floor Landing-12 (+13350mm) 1.0 9.75 P-l 9.75
5.24 25MM THICK KOTA STONE-INCLINED SKIRTING CODE-A12-04 & 4/A14-01 (LOCATION : Staircase)
Lower Ground Level Plan
(Location : Stairacse)
Drg Title : GVM_A4_DETAILED PLAN
Drg Date : 11-09-2025
Mezzanine Level Plan As per A7_staricase & ramp details
(Location : Stairacse)
Drg Title : GVM_A4_DETAILED PLAN
Drg Date : 11-09-2025
Ground Level Plan As per A7_staricase & ramp details
(Location : Stairacse)
Drg Title : GVM_A4_DETAILED PLAN
Drg Date : 11-09-2025
1st Level Plan As per A7_staricase & ramp details
(Location : Stairacse)
Drg Title : GVM_A4_DETAILED PLAN
Drg Date : 11-09-2025
8 FALSE CEILING WORK
8.9 MINERAL FIBRE GRID CEILING 600X600 CODE-A12-07 & 2/A14-04
LOWER GROUND LEVEL PLAN
(Location : Service Entry,Transit Store,4.2m Wide Passage,Staff Break Room,shipping,crate storage,moving tools storage,examine lab,Plinth & panel)
Drg Title : GVM_A12_07_Int Ceiling Diagram
Drg Date : 18-09-2025
4.2m Wide Passage 1.0 1370.08 P-area 1370.08
Ded Of Block Area -1.0 473.34 P-area -473.34
Transit Store 1.0 89.88 P-area 89.88
Staff Break Room 1.0 7.45 6.52 48.57
Shipping 1.0 37.03 P-area 37.03
Crate storage 1.0 31.49 P-area 31.49
Moving tools storage 1.0 36.61 P-area 36.61
Examine lab 1.0 61.45 P-area 61.45
Ded Of Column -1.0 0.44 P-area -0.44
Plinth & Panel 1.0 102.74 P-area 102.74
Ded Of Column -2.0 0.78 0.78 -1.22
MEZZANINE LEVEL PLAN
(Location : MEZZANINE Pssage,Housekeeping Store)
Drg Title : GVM_A12_07_Int Ceiling Diagram
Drg Date : 18-09-2025
Mezzanine Pasage 1.0 133.81 P-area 133.81
Housekeeping Store 1.0 37.10 P-area 37.10
GROUND FLOOR LEVEL PLAN
(Location : 3.4m service Passage,Green Room)
Drg Title : GVM_A12_07_Int Ceiling Diagram
Drg Date : 18-09-2025
3.4m Wide Passage 1.0 223.65 P-area 223.65
Green Room 1.0 107.70 P-area 107.70
1st FLOOR LEVEL PLAN
(Location : 3.4m Service Passage)
Drg Title : GVM_A12_07_Int Ceiling Diagram
Drg Date : 18-09-2025
3.4m Wide Passage 1.0 216.26 P-area 216.26
2ND FLOOR LEVEL PLAN
(Location : Workstation)
Drg Title : GVM_A12_07_Int Ceiling Diagram
Drg Date : 18-09-2025
Workstation 1.0 182.19 P-area 182.19
8.10 GYPSUM + PAINT CODE-A12-07 & 5/A14-04
GROUND FLOOR LEVEL PLAN
(Location : Male Toilet,Female Toilet, Baby care)
Drg Title : GVM_A12_07_Int Ceiling Diagram
Drg Date : 18-09-2025
Male Toilet 1.0 41.28 P-area 41.28
Female Toilet 1.0 31.77 P-area 31.77
Male Toilet 1.0 32.49 P-area 32.49
Female Toilet 1.0 25.53 P-area 25.53
First Ad 1.0 11.00 P-area 11.00
1ST FLOOR LEVEL PLAN
(Location : Male Toilet,Female Toilet, Baby care)
Drg Title : GVM_A12_07_Int Ceiling Diagram
Drg Date : 18-09-2025
Male Toilet 1.0 39.03 P-area 39.03
Female Toilet 1.0 31.75 P-area 31.75
2ND FLOOR LEVEL PLAN
(Location : Male Toilet,Female Toilet,Lobby,File Rm,Docent Lounge,Conference,Building Management,Curatorial,Senior Admin,Meeting Rm,Director Rm,Director Toilet)
Drg Title : GVM_A12_07_Int Ceiling Diagram
Drg Date : 18-09-2025
Male Toilet 1.0 17.57 P-area 17.57
Female Toilet 1.0 8.23 P-area 8.23
Lobby 1.0 38.91 P-area 38.91
File Rm 1.0 13.33 P-area 13.33
Docent Lounge 1.0 18.90 P-area 18.90
Conference 1.0 64.51 P-area 64.51
Building management 1.0 17.16 P-area 17.16
Curatorial 1.0 11.49 P-area 11.49
Senior Admin 1.0 11.70 P-area 11.70
Meeting Rm 1.0 14.02 P-area 14.02
Director 1.0 18.01 P-area 18.01
Director Toilet 1.0 2.20 1.36 2.99
8.11 PLASTER FINISH CODE-A12-07
1ST FLOOR LEVEL PLAN
(Location :ELEV-A1)
Drg Title : GVM_A12_07_Int Ceiling Diagram
Drg Date : 18-09-2025
2ND FLOOR LEVEL PLAN
(Location : ELEV-01,ELEV-02,SHAFT)
Drg Title : GVM_A12_07_Int Ceiling Diagram
Drg Date : 18-09-2025
Shaft 1.0 6.14 P-area 6.14
Shaft 1.0 6.70 P-area 6.70
8.15 M.R GRADE GYPSUM GRID 600X600 CODE-A12-07 & 7/A14-04
LOWER GROUND LEVEL PLAN
(Location : female toilet,male toilet,first aid,storage)
Drg Title : GVM_A12_07_Int Ceiling Diagram
Drg Date : 18-09-2025
Female Toilet 1.0 18.89 P-area 18.89
Male Toilet 1.0 17.70 0.98 17.35
Firsr Aid 1.0 8.03 P-area 8.03
MEZZANINE LEVEL PLAN
(Location : Male & Female Toilet,Male & Female Locker Room)
Drg Title : GVM_A12_07_Int Ceiling Diagram
Drg Date : 18-09-2025
Male Staff Toilet 1.0 17.71 P-area 17.71
Female Staff Toilet 1.0 18.88 P-area 18.88
Male Staff Locker Room 1.0 21.05 P-area 21.05
Female Staff Locker Room 1.0 14.58 P-area 14.58
GROUND FLOOR LEVEL PLAN
(Location : AHU,STAFF CHANGING ROOM,audi toilet)
Drg Title : GVM_A12_07_Int Ceiling Diagram
Drg Date : 18-09-2025
Kitchen Staff Changing Room 1.0 3.27 3.03 9.91
Audi Toilet 1.0 3.39 P-area 3.39
Audi Toilet 1.0 4.48 P-area 4.48
8.12 METAL CEILING CODE-A12-07 & 11/A14-04
GROUND FLOOR LEVEL PLAN
(Location : Kithcen)
Drg Title : GVM_A12_07_Int Ceiling Diagram
Drg Date : 18-09-2025
Kitchen 1.0 212.34 P-area 212.34
Ded Of Wall Area -1.0 4.80 P-area -4.80
2ND FLOOR LEVEL PLAN
(Location : Pantry)
Drg Title : GVM_A12_07_Int Ceiling Diagram
Drg Date : 18-09-2025
Pantry 1.0 6.56 P-area 6.56
8.13 PLASTER + PAINT CODE-A12-07 & 5/A14-04
BASEMENT LEVEL PLAN
(Location : STAIRCASE)
Drg Title : GVM_A12_07_Int Ceiling Diagram
Drg Date : 18-09-2025
Staircase-1-A7-18
Mid-Landing-2 1.0 2.00 2.00 4.00
Midlanding-3 1.0 9.19 P-Area 9.19
Midlanding-4 1.0 2.00 2.00 4.00
LOWER GROUND LEVEL PLAN
(Location : Loading & unloading Bay)
Drg Title : GVM_A12_07_Int Ceiling Diagram
Drg Date : 18-09-2025
Loading & unloading Bay 1.0 121.87 P-area 121.87
Staircase-1-A7-18
Mid-Landing-2 1.0 2.00 2.00 4.00
Midlanding-3 1.0 9.19 P-Area 9.19
Midlanding-4 1.0 2.00 2.00 4.00
8.14 SOUND ATTENUATION CODE-A12-07 & 7/A14-04
LOWER GROUND LEVEL PLAN
(Location : Chillar Rm,Server Rm,Security Monitor,AV Store,it Work Rm)
Drg Title : GVM_A12_07_Int Ceiling Diagram
Drg Date : 18-09-2025
Chillar Rm 1.0 121.56 P-area 121.56
Server Rm 1.0 42.91 P-area 42.91
Ded Of Column -1.0 0.75 0.50 -0.38
Ded Of Column -1.0 1.00 0.75 -0.75
Security Monitor 1.0 35.73 P-area 35.73
IT Work Rm 1.0 53.59 P-area 53.59
AV Store 1.0 50.30 P-area 50.30
MEZZANINE LEVEL PLAN
(Location : Electric Rm,BVS Rm,AHU)
Drg Title : GVM_A12_07_Int Ceiling Diagram
Drg Date : 16-09-2025
Electric Rm 1.0 5.67 3.75 21.26
Ded Of Column -1.0 0.47 P-area -0.47
GROUND FLOOR LEVEL PLAN
(Location : Foldiing Furniture store)
Drg Title : GVM_A12_07_Int Ceiling Diagram
Drg Date : 18-09-2025
Folding Furniture Store 1.0 21.27 P-area 21.27
Control Rm 1.0 7.10 4.35 30.89
AHU 1.0 31.59 P-area 31.59
1ST FLOOR LEVEL PLAN
(Location : AHU)
Drg Title : GVM_A12_07_Int Ceiling Diagram
Drg Date : 18-09-2025
AHU 1.0 30.80 P-area 30.80
AHU 1.0 37.67 P-area 37.67
AHU 1.0 35.19 P-area 35.19
2ND FLOOR LEVEL PLAN
(Location : AHU)
Drg Title : GVM_A12_07_Int Ceiling Diagram
Drg Date : 18-09-2025
AHU 1.0 19.18 P-area 19.18
15.13 GRANITE COUNTER
Lower ground floor
(Location : ELIPTICAL )
Drg Date : 19-09-2025
FACIA - GRANITE
(Location : ELIPTICAL )
Drg Date : 19-09-2025
(Location : ELIPTICAL )
Drg Date : 19-09-2025
Toilet , 7.0 7.00
GRANITE COUNTER
(Location : ELIPTICAL )
Drg Date : 19-09-2025
FACIA - GRANITE
(Location : ELIPTICAL )
Drg Date : 19-09-2025
(Location : ELIPTICAL )
Drg Date : 19-09-2025
Toilet , 6.0 6.00
GRANITE COUNTER
(Location : ELIPTICAL )
Drg Date : 19-09-2025
FACIA - GRANITE
(Location : ELIPTICAL )
Drg Date : 19-09-2025
(Location : ELIPTICAL )
Drg Date : 19-09-2025
Toilet , 7.0 7.00
GRANITE COUNTER
(Location : ELIPTICAL )
Drg Date : 19-09-2025
FACIA - GRANITE
(Location : ELIPTICAL )
Drg Date : 19-09-2025
Toilet 1.0 1.80 1.80
(Location : ELIPTICAL )
Drg Date : 19-09-2025
Toilet , 3.0 3.00
LOWER GROUND FLOOR
(Location : ELIPTICAL )
Drg Title : GVM_A4_DETAILES PLAN_10-09-25
Drg Date : 19-09-2025
L-Shape 2.0 2.00
L-Shape 2.0 2.00
MEZZANINE FLOOR
(Location : ELIPTICAL )
Drg Title : GVM_A4_DETAILES PLAN_10-09-25
Drg Date : 19-09-2025
L-Shape 2.0 2.00
L-Shape 2.0 2.00
(Location : ELIPTICAL )
Drg Title : GVM_A4_DETAILES PLAN_10-09-25
Drg Date : 19-09-2025
L-Shape 6.0 6.00
L-Shape 4.0 4.00
L-Shape 5.0 5.00
L-Shape 3.0 3.00
(Location : ELIPTICAL )
Drg Title : GVM_A4_DETAILES PLAN_10-09-25
Drg Date : 19-09-2025
L-Shape 6.0 6.00
L-Shape 4.0 4.00
(Location : ELIPTICAL )
Drg Title : GVM_A4_DETAILES PLAN_10-09-25
Drg Date : 19-09-2025
L-Shape 1.0 1.00
L-Shape 1.0 1.00
LOWER GROUND FLOOR
(Location : ELIPTICAL )
Drg Title : GVM_A4_DETAILES PLAN_10-09-25
Drg Date : 19-09-2025
I-Shape 3.0 3.00
I-Shape 2.0 2.00
MEZZANINE FLOOR
(Location : ELIPTICAL )
Drg Title : GVM_A4_DETAILES PLAN_10-09-25
Drg Date : 19-09-2025
I-Shape 3.0 3.00
I-Shape 2.0 2.00
(Location : ELIPTICAL )
Drg Title : GVM_A4_DETAILES PLAN_10-09-25
Drg Date : 19-09-2025
I-Shape 1.0 1.00
I-Shape 1.0 1.00
I-Shape 2.0 2.00
I-Shape 1.0 1.00
(Location : ELIPTICAL )
Drg Title : GVM_A4_DETAILES PLAN_10-09-25
Drg Date : 19-09-2025
I-Shape 1.0 1.00
I-Shape 1.0 1.00
(Location : ELIPTICAL )
Drg Title : GVM_A4_DETAILES PLAN_10-09-25
Drg Date : 19-09-2025
I-Shape 1.0 1.00
I-Shape 1.0 1.00
URINAL PARTITION
LOWER GROUND FLOOR
(Location : ELIPTICAL )
Drg Title : GVM_A4_DETAILES PLAN_10-09-25
Drg Date : 19-09-2025
MEZZANINE FLOOR
(Location : ELIPTICAL )
Drg Title : GVM_A4_DETAILES PLAN_10-09-25
Drg Date : 19-09-2025
(Location : ELIPTICAL )
Drg Title : GVM_A4_DETAILES PLAN_10-09-25
Drg Date : 19-09-2025
(Location : ELIPTICAL )
Drg Title : GVM_A4_DETAILES PLAN_10-09-25
Drg Date : 19-09-2025
(Location : ELIPTICAL )
Drg Title : GVM_A4_DETAILES PLAN_10-09-25
Drg Date : 19-09-2025
9 PARAPET FINISH
9.1 2 SIDE PLASTER
Drg Title : 2025-09-18_GVM_A12-08,09-EXT ROOF ,COPING LVL DIAGRAM
Drg Date : 19-09-2025
North building 2.0 16.39 1.10 36.07
9.4 2 SIDE STONE CLADDING
Drg Title : 2025-09-18_GVM_A12-08,09-EXT ROOF ,COPING LVL DIAGRAM
Drg Date : 19-09-2025
North building 2.0 10.89 1.13 24.56
9.2 EXTENDED CLADDING
Drg Title : 2025-09-18_GVM_A12-08,09-EXT ROOF ,COPING LVL DIAGRAM
Drg Date : 19-09-2025
North building 1.0 6.10 1.13 6.88
9.2 1 SIDE STONE CLADDING
Drg Title : 2025-09-18_GVM_A12-08,09-EXT ROOF ,COPING LVL DIAGRAM
Drg Date : 19-09-2025
North building 1.0 27.03 0.49 13.24
North building 1.0 13.12 0.49 6.43
Drg Title : 2025-09-18_GVM_A12-08,09-EXT ROOF ,COPING LVL DIAGRAM
Drg Date : 19-09-2025
North building 1.0 207.61 0.49 101.73
North building 1.0 91.78 0.49 44.97
North building 1.0 59.65 0.49 29.23
North building 1.0 9.02 0.49 4.42
North building 1.0 66.76 0.49 32.71
9.5 S.S CLADDING
Drg Title : 2025-09-18_GVM_A12-08,09-EXT ROOF ,COPING LVL DIAGRAM
Drg Date : 19-09-2025
North building 1.0 49.00 0.35 17.15
10 FLASHING TYPE
10.1 FLASHING TYPE 1 CODE-A11-01 & 5/A11-01
Flashing Width =.350
Drg Title : 2025-09-18_GVM_A12-08,09-EXT ROOF ,COPING LVL DIAGRAM
Drg Date : 19-09-2025
North building 1.0 24.73 0.49 12.12
North building 1.0 6.49 0.49 3.18
Drg Title : 2025-09-18_GVM_A12-08,09-EXT ROOF ,COPING LVL DIAGRAM
Drg Date : 19-09-2025
North Buidling 1.0 17.65 17.65
North Buidling 1.0 33.02 33.02
North Buidling 1.0 33.55 33.55
North Buidling 2.0 2.55 5.10
North Buidling 1.0 15.00 15.00
10.2 FLASHING TYPE 2 CODE-A11-01 & 6/A11-01
Drg Title : 2025-09-18_GVM_A12-08,09-EXT ROOF ,COPING LVL DIAGRAM
Drg Date : 19-09-2025
North Building 2.0 3.20 6.40
10.3 FLASHING TYPE 3 CODE-A11-01 & 7/A11-01
Drg Title : 2025-09-18_GVM_A12-08,09-EXT ROOF ,COPING LVL DIAGRAM
Drg Date : 19-09-2025
North Building 1.0 111.01 111.01
North Building 1.0 12.81 12.81
North Building 1.0 30.20 30.20
North Building 1.0 39.84 39.84
North Building 1.0 39.54 39.54
North Building 1.0 121.50 121.50
10.4 FLASHING TYPE 4 CODE-A11-01 & 7A/A11-01
Drg Title : 2025-09-18_GVM_A12-08,09-EXT ROOF ,COPING LVL DIAGRAM
Drg Date : 19-09-2025
North Building 2.0 20.10 40.20
11 ROOF LEVEL FINISH
11.1 LOOSE GRAVEL STONE CODE-A12-09 & 15/A14-01
Drg Title : 2025-09-18_GVM_A12-08,09-EXT ROOF ,COPING LVL DIAGRAM
Drg Date : 19-09-2025
North block roof 1.0 794.50 794.50
11.4 ZINC ROOFING CODE-A12-09 & 15/A14-01
Drg Title : 2025-09-18_GVM_A12-08,09-EXT ROOF ,COPING LVL DIAGRAM
Drg Date : 19-09-2025
Entrance lobby roof roof 1.0 1402.15 1402.15
Bountiful gujarat roof 1.0 86.10 86.10
11.2 GREEN ROOF CODE-A12-09 & 15/A14-01
Drg Title : 2025-09-18_GVM_A12-08,09-EXT ROOF ,COPING LVL DIAGRAM
Drg Date : 19-09-2025
Green Roof 1.0 552.03 552.03
12 DRAINAGE WALL FINISH (A12-11)
12.2 STONE WALL-STONE FLOOR DRAIN CODE-A12-11 & 2/A11-02
LOWER GROUND FLOOR
Drg Title : 2025-09-18_GVM_A12-11-DRAINAGE DIAGRAM
Drg Date : 19-09-2025
At service entry 1.0 0.85 0.85
at stair 1.0 4.10 4.10
Drg Title : 2025-09-18_GVM_A12-11-DRAINAGE DIAGRAM
Drg Date : 19-09-2025
outside passage 1.0 9.86 9.86
rest.outdoor 1.0 5.10 5.10
Entrance lobby 1.0 31.05 31.05
12.3 ALUM. GLAZING - STONE FLOOR DRAIN CODE-A12-11 & 3/A11-02
LOWER GROUND FLOOR
Drg Title : 2025-09-18_GVM_A12-11-DRAINAGE DIAGRAM
Drg Date : 19-09-2025
At service entry 9.0 1.20 10.80
Drg Title : 2025-09-18_GVM_A12-11-DRAINAGE DIAGRAM
Drg Date : 19-09-2025
at passage 9.0 1.80 16.20
12.5 STONE FLOOR - STONE FLOOR DRAIN CODE-A12-11 & 5/A11-02
LOWER GROUND FLOOR
Drg Title : 2025-09-18_GVM_A12-11-DRAINAGE DIAGRAM
Drg Date : 19-09-2025
At service entry 2.0 1.50 3.00
Drg Title : 2025-09-18_GVM_A12-11-DRAINAGE DIAGRAM
Drg Date : 19-09-2025
At service entry 1.0 1.50 1.50
at entrance 1.0 40.10 40.10
12.6 STONE FLOOR - ROAD DRAIN (HEAVY DUTY) CODE-A12-11 & 6/A11-02
LOWER GROUND FLOOR
Drg Title : 2025-09-18_GVM_A12-11-DRAINAGE DIAGRAM
Drg Date : 19-09-2025
At loading bay 1.0 6.60 6.60
13 WATERPROOFING BELOW GROUND LEVEL
13.1 1.2 mm HDPE MEMBRANE PRESSURE SENSITIVE ADHESIVE (Below Footing)
Drg Title : A12-14A,B,C- WATERPROOFING DIAGRAM
Drg Date : 01-04-2026
13.2 1.2MM CROSS LAMINATED SBS MODIFIED MEMBRANE + 8MM THK HDPE PROTECTION BOARD
Drg Title : A12-14A,B,C- WATERPROOFING DIAGRAM
Drg Date : 01-04-2026
13.3 1.2 mm HDPE MEMBRANE PRESSURE SENSITIVE ADHESIVE (below grade slab)
Drg Title : A12-14A,B,C- WATERPROOFING DIAGRAM
Drg Date : 01-04-2026
BLOCK A 1.0 1055.95 P-area 1055.95
BLOCK B 1.0 914.82 P-area 914.82
BLOCK C 1.0 791.13 P-area 791.13
13.3 1.2 mm HDPE MEMBRANE PRESSURE SENSITIVE ADHESIVE (below grade slab)
Drg Title : A12-14A,B,C- WATERPROOFING DIAGRAM
Drg Date : 01-04-2026
RETAINING WALL 1.0 3.60 0.30 0.60 4.32
BLOCK B 0.60 0.00
14.1 300 MM HIGH GUARD RAIL CODE-A12-12 & 03/A7-22
Ground Level Plan As per A7_staricase & ramp details
(Location : Stairacse)
Drg Title : GVM_A4_DETAILED PLAN
Drg Date : 11-09-2025
7.2m wide Corridor 9.0 1.80 16.20
14.3 900MM HIGH WALL MOUNTED S.S RAIL CODE-A12-12 & 01/A7-22
LOWER GROUND FLOOR
Drg Title : 2025-09-18_GVM_A0-12_SUNK DIAGRAM
Drg Date : 19-09-2025
Floor Landing-01 (-9900mm) 1.0 5.60 P-line 5.60
Floor Landing-02 (-9000mm) 1.0 4.26 4.26
Mid-landing-4 (-7200mm) 1.0 11.25 P-line 11.25
Mid-landing-5 (-5400mm) 1.0 8.95 P-line 8.95
Mid-landing-6 (-3600mm) 1.0 9.72 P-line 9.72
Mid-landing-7 (-1800mm) 1.0 8.95 P-line 8.95
Floor Landing-01 (-8400mm) 1.0 13.30 P-line 13.30
Mid-landing-2 (-6600mm) 1.0 8.75 P-line 8.75
Loading Bay Ramp 1.0 11.22 11.22
Service entry 1.0 23.287 23.29
Mezzanine Level Plan As per A7_staricase & ramp details
(Location : Stairacse)
Drg Title : GVM_A4_DETAILED PLAN
Drg Date : 11-09-2025
Floor Landing-01 (-4800mm) 1.0 31.89 P-line 31.89
Mid Landing-02 (-3600mm) 1.0 8.72 P-line 8.72
Mid Landing-03 (-1800mm) 1.0 9.95 P-line 9.95
Floor Landing-03 (-4800mm) 1.0 15.55 P-line 15.55
Mid-landing-4 (-3000mm) 1.0 8.73 P-line 8.73
Mid-landing-5 (-1500mm) 1.0 9.95 P-line 9.95
Ground Level Plan As per A7_staricase & ramp details
(Location : Stairacse)
Drg Title : GVM_A4_DETAILED PLAN
Drg Date : 11-09-2025
Floor Landing-01 (0mm) 1.0 11.46 P-line 11.46
Mid-landing-9 (+1500mm) 1.0 11.52 P-line 11.52
Mid-landing-10 (+3000mm) 1.0 11.46 P-line 11.46
Mid-landing-11 (+4500mm) 1.0 11.52 P-line 11.52
Floor Landing-06 (0mm) 1.0 11.66 P-line 11.66
Mid Landing-07 (+1500 mm) 1.0 11.15 P-line 11.15
Mid Landing-08 (+3000mm) 1.0 8.75 P-line 8.75
Floor Landing-09 (+4500mm) 1.0 9.95 P-line 9.95
Floor Landing-04 (00mm) 1.0 11.26 P-line 11.26
Mid Landing-05 (+1500 mm) 1.0 9.95 P-line 9.95
Mid Landing-06 (+3000 mm) 1.0 9.95 P-line 9.95
Mid Landing-07 (+4500 mm) 1.0 8.75 P-line 8.75
1st Level Plan As per A7_staricase & ramp details
(Location : Stairacse)
Drg Title : GVM_A4_DETAILED PLAN
Drg Date : 11-09-2025
Floor Landing-01 (8000mm) 1.0 11.46 P-line 11.46
Floor Landing-10 (+6000mm) 1.0 11.95 P-line 11.95
Mid Landing-11 (+7800 mm) 1.0 9.95 P-line 9.95
Mid Landing-12 (+9600mm) 1.0 8.75 P-line 8.75
Floor Landing-13 (+11400mm) 1.0 8.75 P-line 8.75
Floor Landing-08 (+6000mm) 1.0 12.46 P-line 12.46
Mid Landing-09 (+7800 mm) 1.0 8.75 P-line 8.75
Mid Landing-10 (+9600 mm) 1.0 8.75 P-line 8.75
Mid Landing-11 (+11400 mm) 1.0 8.75 P-line 8.75
2nd Level Plan As per A7_staricase & ramp details
(Location : Stairacse)
Drg Title : GVM_A4_DETAILED PLAN
Drg Date : 11-09-2025
Floor Landing-14 (+13350mm) 1.0 11.43 11.43
Floor Landing-12 (+13350mm) 1.0 9.75 9.75
14.5 1100 MM HIGH GLASS WITH WOODEN RAIL CODE-A12-12 & 09/A7-22
1st floor As per A7_staricase & ramp details
Drg Title : GVM_A4_DETAILED PLAN
Drg Date : 11-09-2025
14.7 900 MM HIGH G.I RAILING CODE-A12-12 & 07/A7-22
LOWER GROUND FLOOR
Drg Title : 2025-09-18_GVM_A0-12_SUNK DIAGRAM
Drg Date : 19-09-2025
Loading bay 1.0 3.00 3.00
Drg Title : 2025-09-18_GVM_A0-12_SUNK DIAGRAM
Drg Date : 19-09-2025
Control rm 1.0 3.00 3.00
14 COPING FINISH
9.1 COPING 1 CODE-A11-01 & 4/A11-01
Drg Title : 2025-09-18_GVM_A12-08,09-EXT ROOF ,COPING LVL DIAGRAM
Drg Date : 19-09-2025
North building 2.0 16.39 0.39 12.79
9.4 COPING 4 CODE-A11-01 & 3/A11-01
Drg Title : 2025-09-18_GVM_A12-08,09-EXT ROOF ,COPING LVL DIAGRAM
Drg Date : 19-09-2025
North building 2.0 10.89 0.60 13.06
9.3 COPING 3 CODE-A11-01 & 2/A11-01
Drg Title : 2025-09-18_GVM_A12-08,09-EXT ROOF ,COPING LVL DIAGRAM
Drg Date : 19-09-2025
North building 1.0 6.10 0.62 3.76
9.2 COPING 2 CODE-A11-01 & 1/A11-01
Drg Title : 2025-09-18_GVM_A12-08,09-EXT ROOF ,COPING LVL DIAGRAM
Drg Date : 19-09-2025
North building 1.0 27.03 0.49 13.24
North building 1.0 13.12 0.49 6.43
Drg Title : 2025-09-18_GVM_A12-08,09-EXT ROOF ,COPING LVL DIAGRAM
Drg Date : 19-09-2025
North building 1.0 207.61 0.49 101.73
North building 1.0 91.78 0.49 44.97
North building 1.0 59.65 0.49 29.23
North building 1.0 9.02 0.49 4.42
North building 1.0 66.76 0.49 32.71
DRG : 2025-09-18_GVM_A12-14-ROLLER BLINDS DIAGRAM
Drg Date : 19-09-2025
Lower Ground floor
DRG : 2025-09-18_GVM_A12-14-ROLLER BLINDS DIAGRAM
Drg Date : 19-09-2025
DRG : 2025-09-18_GVM_A12-14-ROLLER BLINDS DIAGRAM
Drg Date : 19-09-2025
DRG : 2025-09-18_GVM_A12-14-ROLLER BLINDS DIAGRAM
Drg Date : 19-09-2025
9.2 EXPANSION JOINT-EXTERIOR CODE-A12-13 & A11-03
2 ROOF TYPE - 1 (1-A11-03)
Drg Title : 2025-09-18_GVM_A12-08,09-EXT ROOF ,COPING LVL DIAGRAM
Drg No : A12-13
Drg Date : 19-09-2025
2 ROOF TYPE - 2 (2-A11-03)
Drg Title : 2025-09-18_GVM_A12-08,09-EXT ROOF ,COPING LVL DIAGRAM
Drg No : A12-13
Drg Date : 19-09-2025
Drg Title : 2025-09-18_GVM_A12-08,09-EXT ROOF ,COPING LVL DIAGRAM
Drg No : A12-13
Drg Date : 19-09-2025
3 ROOF TYPE - 3 (A11-03)
LOWER GROUD FLOOR
Drg Title : 2025-09-18_GVM_A12-08,09-EXT ROOF ,COPING LVL DIAGRAM
Drg No : A12-13
Drg Date : 19-09-2025
Drg Title : 2025-09-18_GVM_A12-08,09-EXT ROOF ,COPING LVL DIAGRAM
Drg No : A12-13
Drg Date : 19-09-2025
Drg Title : 2025-09-18_GVM_A12-08,09-EXT ROOF ,COPING LVL DIAGRAM
Drg No : A12-13
Drg Date : 19-09-2025
Drg Title : 2025-09-18_GVM_A12-08,09-EXT ROOF ,COPING LVL DIAGRAM
Drg No : A12-13
Drg Date : 19-09-2025
4 WALL TYPE - 1 (4-A11-03)
Drg Title : 2025-09-18_GVM_A12-08,09-EXT ROOF ,COPING LVL DIAGRAM
Drg No : A12-13
Drg Date : 19-09-2025
Drg Title : 2025-09-18_GVM_A12-08,09-EXT ROOF ,COPING LVL DIAGRAM
Drg No : A12-13
Drg Date : 19-09-2025
LOWER GROUD FLOOR
Drg Title : 2025-09-18_GVM_A12-08,09-EXT ROOF ,COPING LVL DIAGRAM
Drg No : A12-13
Drg Date : 19-09-2025
MEZZANINE FLOOR
Drg Title : 2025-09-18_GVM_A12-08,09-EXT ROOF ,COPING LVL DIAGRAM
Drg No : A12-13
Drg Date : 19-09-2025
Drg Title : 2025-09-18_GVM_A12-08,09-EXT ROOF ,COPING LVL DIAGRAM
Drg No : A12-13
Drg Date : 19-09-2025
Drg Title : 2025-09-18_GVM_A12-08,09-EXT ROOF ,COPING LVL DIAGRAM
Drg No : A12-13
Drg Date : 19-09-2025
Drg Title : 2025-09-18_GVM_A12-08,09-EXT ROOF ,COPING LVL DIAGRAM
Drg No : A12-13
Drg Date : 19-09-2025
9.2 EXPANSION JOINT-INTERIOR CODE-A12-13 & A11-03
1 WALL TYPE-3 (5-A14-11)
LOWER GROUD FLOOR
Drg Title : 2025-09-18_GVM_A12-08,09-EXT ROOF ,COPING LVL DIAGRAM
Drg No : A12-13
Drg Date : 19-09-2025
MEZZANINE FLOOR
Drg Title : 2025-09-18_GVM_A12-08,09-EXT ROOF ,COPING LVL DIAGRAM
Drg No : A12-13
Drg Date : 19-09-2025
Drg Title : 2025-09-18_GVM_A12-08,09-EXT ROOF ,COPING LVL DIAGRAM
Drg No : A12-13
Drg Date : 19-09-2025
Drg Title : 2025-09-18_GVM_A12-08,09-EXT ROOF ,COPING LVL DIAGRAM
Drg No : A12-13
Drg Date : 19-09-2025
2 FLOORING TYPE-1 (1-A14-11)
Drg Title : 2025-09-18_GVM_A12-08,09-EXT ROOF ,COPING LVL DIAGRAM
Drg No : A12-13
Drg Date : 19-09-2025
Drg Title : 2025-09-18_GVM_A12-08,09-EXT ROOF ,COPING LVL DIAGRAM
Drg No : A12-13
Drg Date : 19-09-2025
3 FLOORING TYPE-2 (2-A14-11)
Drg Title : 2025-09-18_GVM_A12-08,09-EXT ROOF ,COPING LVL DIAGRAM
Drg No : A12-13
Drg Date : 19-09-2025
Drg Title : 2025-09-18_GVM_A12-08,09-EXT ROOF ,COPING LVL DIAGRAM
Drg No : A12-13
Drg Date : 19-09-2025
4 FLOORING TYPE-3 (3-A14-11)
MEZZANINE FLOOR
Drg Title : 2025-09-18_GVM_A12-08,09-EXT ROOF ,COPING LVL DIAGRAM
Drg No : A12-13
Drg Date : 19-09-2025
Drg Title : 2025-09-18_GVM_A12-08,09-EXT ROOF ,COPING LVL DIAGRAM
Drg No : A12-13
Drg Date : 19-09-2025
Drg Title : 2025-09-18_GVM_A12-08,09-EXT ROOF ,COPING LVL DIAGRAM
Drg No : A12-13
Drg Date : 19-09-2025
Drg Title : 2025-09-18_GVM_A12-08,09-EXT ROOF ,COPING LVL DIAGRAM
Drg No : A12-13
Drg Date : 19-09-2025
5 FLOORING TYPE-3 (4-A14-11)
Drg Title : 2025-09-18_GVM_A12-08,09-EXT ROOF ,COPING LVL DIAGRAM
Drg No : A12-13
Drg Date : 19-09-2025
Drg Title : 2025-09-18_GVM_A12-08,09-EXT ROOF ,COPING LVL DIAGRAM
Drg No : A12-13
Drg Date : 19-09-2025
Drg Title : 2025-09-18_GVM_A12-08,09-EXT ROOF ,COPING LVL DIAGRAM
Drg No : A12-13
Drg Date : 19-09-2025
SuPr ENGINEERING CONSULTANTS 307, SIDDHARTH UPSCALE, VASNA ROAD VADODARA-390007 TEL- 0265-3149701 SUMMARY
VADODARA PROJECT : GUJARAT VANDANA MUSEUM, GUJARAT
DATE : 05-09-25 ARCHITECT : OPOLIS
PREPARED BY : MANDIPSINH CLIENT : DIRECTORATE OF ARCHEOLOGY AND MUSEUMS, G.O.G
SR. NO. PARTICULAR UNIT QTY. NO. OF FLOORS TOTAL QTY. QTY. WITH CONTIGENCY
R0 DWGS-RECD-07.07.25
2 MASONRY WORK (FLY ASH WALL)
2.1 100MM THICK FLY BLOCK MASONRY CODE-A13-01 & 1/A13-08
Basement Floor Cum 0.00 1.00 0.00
Lower Ground Floor Cum 1.38 1.00 1.38
Mezzanine Floor Cum 0.00 1.00 0.00
Ground Floor Cum 1.25 1.00 1.25
First Floor Cum 1.30 1.00 1.30
Mezzanine Floor Cum 0.00 1.00 0.00
Second Floor Cum 0.00 1.00 0.00
Third Floor Cum 0.00 1.00 0.00
Fourth Floor Cum 0.00 1.00 0.00
Total Cum 3.93 5.00
2.2 125MM THICK FLY BLOCK MASONRY CODE-A13-01 & 1/A13-08
Basement Floor Cum 0.00 1.00 0.00
Lower Ground Floor Cum 0.00 1.00 0.00
Mezzanine Floor Cum 0.00 1.00 0.00
Ground Floor Cum 0.00 1.00 0.00
First Floor Cum 0.00 1.00 0.00
Mezzanine Floor Cum 0.00 1.00 0.00
Second Floor Cum 0.00 1.00 0.00
Third Floor Cum 0.00 1.00 0.00
Fourth Floor Cum 0.00 1.00 0.00
Total Cum 0.00 0.00
2.3 150MM THICK FLY BLOCK MASONRY CODE-A13-01 & 1/A13-08
Basement Floor Cum 0.00 1.00 0.00
Lower Ground Floor Cum 1.42 1.00 1.42
Mezzanine Floor Cum 0.00 1.00 0.00
Ground Floor Cum 2.22 1.00 2.22
First Floor Cum 0.00 1.00 0.00
Mezzanine Floor Cum 0.00 1.00 0.00
Second Floor Cum 0.00 1.00 0.00
Third Floor Cum 0.00 1.00 0.00
Fourth Floor Cum 0.00 1.00 0.00
Total Cum 3.64 4.00
2.4 200MM THICK FLY BLOCK MASONRY CODE-A13-01 & 1/A13-08
Basement Floor Cum 0.00 1.00 0.00
Lower Ground Floor Cum 0.00 1.00 0.00
Mezzanine Floor Cum 0.00 1.00 0.00
Ground Floor Cum 0.00 1.00 0.00
First Floor Cum 0.00 1.00 0.00
Mezzanine Floor Cum 0.00 1.00 0.00
Second Floor Cum 0.00 1.00 0.00
Third Floor Cum 0.00 1.00 0.00
Fourth Floor Cum 0.00 1.00 0.00
Total Cum 0.00 0.00
2.5 250MM THICK FLY BLOCK MASONRY CODE-A13-01 & 1/A13-08
Basement Floor Cum 0.00 1.00 0.00
Lower Ground Floor Cum 182.86 1.00 182.86
Mezzanine Floor Cum 0.00 1.00 0.00
Ground Floor Cum 264.53 1.00 264.53
First Floor Cum 290.61 1.00 290.61
Mezzanine Floor Cum 0.00 1.00 0.00
Second Floor Cum 0.00 1.00 0.00
Third Floor Cum 0.00 1.00 0.00
Fourth Floor Cum 0.00 1.00 0.00
Total Cum 738.00 775.00
2.6 300MM THICK FLY BLOCK MASONRY CODE-A13-01 & 1/A13-08
Basement Floor Cum 0.00 1.00 0.00
Lower Ground Floor Cum 29.91 1.00 29.91
Mezzanine Floor Cum 0.00 1.00 0.00
Ground Floor Cum 30.12 1.00 30.12
First Floor Cum 33.82 1.00 33.82
Mezzanine Floor Cum 0.00 1.00 0.00
Second Floor Cum 0.00 1.00 0.00
Third Floor Cum 0.00 1.00 0.00
Fourth Floor Cum 0.00 1.00 0.00
Total Cum 93.85 99.00
2.7 350MM THICK FLY BLOCK MASONRY CODE-A13-01 & 1/A13-08
Basement Floor Cum 0.00 1.00 0.00
Lower Ground Floor Cum 0.00 1.00 0.00
Mezzanine Floor Cum 0.00 1.00 0.00
Ground Floor Cum 3.51 1.00 3.51
First Floor Cum 0.00 1.00 0.00
Mezzanine Floor Cum 0.00 1.00 0.00
Second Floor Cum 0.00 1.00 0.00
Third Floor Cum 0.00 1.00 0.00
Fourth Floor Cum 0.00 1.00 0.00
Total Cum 3.51 4.00
2.8 375MM THICK FLY BLOCK MASONRY CODE-A13-01 & 1/A13-08
Basement Floor Cum 0.00 1.00 0.00
Lower Ground Floor Cum 0.00 1.00 0.00
Mezzanine Floor Cum 0.00 1.00 0.00
Ground Floor Cum 0.00 1.00 0.00
First Floor Cum 0.00 1.00 0.00
Mezzanine Floor Cum 0.00 1.00 0.00
Second Floor Cum 0.00 1.00 0.00
Third Floor Cum 0.00 1.00 0.00
Fourth Floor Cum 0.00 1.00 0.00
Total Cum 0.00 0.00
2.9 400MM THICK FLY BLOCK MASONRY CODE-A13-01 & 1/A13-08
Basement Floor Cum 0.00 1.00 0.00
Lower Ground Floor Cum 0.00 1.00 0.00
Mezzanine Floor Cum 0.00 1.00 0.00
Ground Floor Cum 0.00 1.00 0.00
First Floor Cum 0.00 1.00 0.00
Mezzanine Floor Cum 0.00 1.00 0.00
Second Floor Cum 0.00 1.00 0.00
Third Floor Cum 0.00 1.00 0.00
Fourth Floor Cum 1.00 0.00
Total Cum 0.00 0.00
2.10 500MM THICK FLY BLOCK MASONRY CODE-A13-01 & 1/A13-08
Basement Floor Cum 0.00 1.00 0.00
Lower Ground Floor Cum 0.00 1.00 0.00
Mezzanine Floor Cum 0.00 1.00 0.00
Ground Floor Cum 0.00 1.00 0.00
First Floor Cum 0.00 1.00 0.00
Mezzanine Floor Cum 0.00 1.00 0.00
Second Floor Cum 0.00 1.00 0.00
Third Floor Cum 0.00 1.00 0.00
Fourth Floor Cum 1.00 0.00
Total Cum 0.00 0.00
Total of AAC Block Cum 839.00 881.00
3 DRY PARTITION
3.1 100 MM THICK DRY PARTITION WITHOUT INSULATION CODE-A13-01 & 2/A13-08
Basement Floor Sqm 0.00 1.00 0.00
Lower Ground Floor Sqm 0.00 1.00 0.00
Mezzanine Floor Sqm 0.00 1.00 0.00
Ground Floor Sqm 0.00 1.00 0.00
First Floor Sqm 0.00 1.00 0.00
Mezzanine Floor Sqm 0.00 1.00 0.00
Second Floor Sqm 0.00 1.00 0.00
Third Floor Sqm 0.00 1.00 0.00
Fourth Floor Sqm 0.00 1.00 0.00
Total Sqm 0.00 0.00
3.2 100 MM THICK DRY PARTITION WITH INSULATION CODE-A13-01 & 3/A13-08
Basement Floor Sqm 0.00 1.00 0.00
Lower Ground Floor Sqm 0.00 1.00 0.00
Mezzanine Floor Sqm 0.00 1.00 0.00
Ground Floor Sqm 0.00 1.00 0.00
First Floor Sqm 0.00 1.00 0.00
Mezzanine Floor Sqm 0.00 1.00 0.00
Second Floor Sqm 0.00 1.00 0.00
Third Floor Sqm 0.00 1.00 0.00
Fourth Floor Sqm 0.00 1.00 0.00
Total Sqm 0.00 0.00
3.3 200 MM THICK DRY PARTITION CODE-A13-01 & 4/A13-08
Basement Floor Sqm 0.00 1.00 0.00
Lower Ground Floor Sqm 0.00 1.00 0.00
Mezzanine Floor Sqm 0.00 1.00 0.00
Ground Floor Sqm 0.00 1.00 0.00
First Floor Sqm 0.00 1.00 0.00
Mezzanine Floor Sqm 0.00 1.00 0.00
Second Floor Sqm 0.00 1.00 0.00
Third Floor Sqm 0.00 1.00 0.00
Fourth Floor Sqm 0.00 1.00 0.00
Total Sqm 0.00 0.00
3.4 300 MM THICK DRY PARTITION (FOR ELIPSE RAMP) CODE-A13-01 & 5/A13-08
Basement Floor Sqm 0.00 1.00 0.00
Lower Ground Floor Sqm 0.00 1.00 0.00
Mezzanine Floor Sqm 0.00 1.00 0.00
Ground Floor Sqm 0.00 1.00 0.00
First Floor Sqm 0.00 1.00 0.00
Mezzanine Floor Sqm 0.00 1.00 0.00
Second Floor Sqm 0.00 1.00 0.00
Third Floor Sqm 0.00 1.00 0.00
Fourth Floor Sqm 0.00 1.00 0.00
Total Sqm 0.00 0.00
4.1 150 MM THICK AAC BLOCK MASONRY CODE-01A13-08
Basement Floor Sqm 0.00 1.00 0.00
Lower Ground Floor Sqm 0.00 1.00 0.00
Mezzanine Floor Sqm 0.00 1.00 0.00
Ground Floor Sqm 0.00 1.00 0.00
First Floor Sqm 0.00 1.00 0.00
Mezzanine Floor Sqm 0.00 1.00 0.00
Second Floor Sqm 0.00 1.00 0.00
Third Floor Sqm 0.00 1.00 0.00
Fourth Floor Sqm 0.00 1.00 0.00
Total Sqm 0.00 0.00
4.2 200 MM THICK AAC BLOCK MASONRY CODE-01A13-08
Basement Floor Cum 0.00 1.00 0.00
Lower Ground Floor Cum 4.71 1.00 4.71
Mezzanine Floor Cum 0.00 1.00 0.00
Ground Floor Cum 0.00 1.00 0.00
First Floor Cum 4.45 1.00 4.45
Mezzanine Floor Cum 0.00 1.00 0.00
Second Floor Cum 0.00 1.00 0.00
Third Floor Cum 0.00 1.00 0.00
Fourth Floor Cum 0.00 1.00 0.00
Total Cum 9.16 10.00
4.3 250 MM THICK AAC BLOCK MASONRY CODE-01A13-08
Basement Floor Cum 0.00 1.00 0.00
Lower Ground Floor Cum 15.38 1.00 15.38
Mezzanine Floor Cum 0.00 1.00 0.00
Ground Floor Cum 20.89 1.00 20.89
First Floor Cum 81.04 1.00 81.04
Mezzanine Floor Cum 0.00 1.00 0.00
Second Floor Cum 0.00 1.00 0.00
Third Floor Cum 0.00 1.00 0.00
Fourth Floor Cum 0.00 1.00 0.00
Total Cum 117.31 124.00
Total of Fly ash Block Cum 126.47 133.00
3 INTERNAL PLATSER WORK
Basement Floor Sqm 0.00 1.00 0.00
Lower Ground Floor Sqm 2145.53 1.00 2145.53
Mezzanine Floor Sqm 0.00 1.00 0.00
Ground Floor Sqm 3233.59 1.00 3233.59
First Floor Sqm 4054.44 1.00 4054.44
Second Floor Sqm 0.00 1.00 0.00
Third Floor Sqm 0.00 1.00 0.00
Fourth Floor Sqm 0.00 1.00 0.00
Total Sqm 9433.55 9906.00
4 INTERNAL PUTTY WORK
Basement Floor Sqm 0.00 1.00 0.00
Lower Ground Floor Sqm 2468.34 1.00 2468.34
Mezzanine Floor Sqm 0.00 1.00 0.00
Ground Floor Sqm 1557.17 1.00 1557.17
First Floor Sqm 296.32 1.00 296.32
Second Floor Sqm 0.00 1.00 0.00
Third Floor Sqm 0.00 1.00 0.00
Fourth Floor Sqm 0.00 1.00 0.00
Total Sqm 4321.82 4538.00
4 CEILING PUTTY WORK
Basement Floor Sqm 0.00 1.00 0.00
Lower Ground Floor Sqm 155.11 1.00 155.11
Mezzanine Floor Sqm 0.00 1.00 0.00
Ground Floor Sqm 754.94 1.00 754.94
First Floor Sqm 0.00 1.00 0.00
Second Floor Sqm 0.00 1.00 0.00
Third Floor Sqm 0.00 1.00 0.00
Fourth Floor Sqm 0.00 1.00 0.00
Total Sqm 910.05 956.00
4 TOILET PLASTER WORK
Basement Floor Sqm 0.00 1.00 0.00
Lower Ground Floor Sqm 397.73 1.00 397.73
Mezzanine Floor Sqm 0.00 1.00 0.00
Ground Floor Sqm 553.16 1.00 553.16
First Floor Sqm 368.88 1.00 368.88
Second Floor Sqm 0.00 1.00 0.00
Third Floor Sqm 0.00 1.00 0.00
Fourth Floor Sqm 0.00 1.00 0.00
Total Sqm 1319.77 1386.00
4 EXTERNAL PLASTER WORK
Basement Floor Sqm 0.00 1.00 0.00
Lower Ground Floor Sqm 633.27 1.00 633.27
Mezzanine Floor Sqm 0.00 1.00 0.00
Ground Floor Sqm 2489.24 1.00 2489.24
First Floor Sqm 2172.21 1.00 2172.21
Second Floor Sqm 1572.42 1.00 1572.42
Third Floor Sqm 0.00 1.00 0.00
Fourth Floor Sqm 0.00 1.00 0.00
Total Sqm 6867.15 7211.00
WATERPROOFING COMPOUND
Total Internal Plaster 12712.98
Total External Plaster 6867.15
Considering 2% by weight of Cement bags 2174.24 1.00 2174.24
PLOYESTER FIBRE
Total Internal Plaster 12712.98
Total External Plaster 6867.15
Total Bags of cement 2174.24
125 gms. of synthetic Polyester triangular fibre for 50 Kgs. Cement 271.78 1.00 271.78
Total Kg 271.78 286.00
13 WATERPROOFING WORK
13.1 LOCATION : TOILET
Basement Floor Sqm 0.00 1.00 0.00
Lower Ground Floor Sqm 110.15 1.00 110.15
Mezzanine Floor Sqm 0.00 1.00 0.00
Ground Floor Sqm 151.76 1.00 151.76
First Floor Sqm 60.61 1.00 60.61
Second Floor Sqm 0.00 1.00 0.00
Third Floor Sqm 0.00 1.00 0.00
Fourth Floor Sqm 0.00 1.00 0.00
Total Sqm 322.52 355.00
13.2 LOCATION : BASEMENT ON FLOOR
Basement Floor Sqm 1.00 0.00
Lower Ground Floor Sqm 1.00 0.00
Mezzanine Floor Sqm 1.00 0.00
Ground Floor Sqm 1.00 0.00
First Floor Sqm 1.00 0.00
Second Floor Sqm 1.00 0.00
Third Floor Sqm 1.00 0.00
Fourth Floor Sqm 1.00 0.00
Total Sqm 0.00 0.00
13.3 LOCATION : BASEMENT ON WALL
Basement Floor Sqm 1.00 0.00
Lower Ground Floor Sqm 1.00 0.00
Mezzanine Floor Sqm 1.00 0.00
Ground Floor Sqm 1.00 0.00
First Floor Sqm 1.00 0.00
Second Floor Sqm 1.00 0.00
Third Floor Sqm 1.00 0.00
Fourth Floor Sqm 1.00 0.00
Total Sqm 0.00 0.00
13.4 LOCATION : TERRACE
Basement Floor Sqm 0.00 1.00 0.00
Lower Ground Floor Sqm 0.00 1.00 0.00
Mezzanine Floor Sqm 0.00 1.00 0.00
Ground Floor Sqm 0.00 1.00 0.00
First Floor Sqm 229.83 1.00 229.83
Second Floor Sqm 0.00 1.00 0.00
Third Floor Sqm 0.00 1.00 0.00
Fourth Floor Sqm 0.00 1.00 0.00
Roof floor Sqm 3581.36 1.00 3581.36
Total Sqm 3811.19 4193.00
13.5 LOCATION : LIFT PIT (INSIDE)
Basement Floor Sqm 0.00 1.00 0.00
Lower Ground Floor Sqm 185.87 1.00 185.87
Mezzanine Floor Sqm 0.00 1.00 0.00
Ground Floor Sqm 0.00 1.00 0.00
First Floor Sqm 0.00 1.00 0.00
Second Floor Sqm 0.00 1.00 0.00
Third Floor Sqm 0.00 1.00 0.00
Fourth Floor Sqm 0.00 1.00 0.00
Total Sqm 185.87 205.00
13.5 LOCATION : LIFT PIT (OUTSIDE WALL)
Basement Floor Sqm 0.00 1.00 0.00
Lower Ground Floor Sqm 149.35 1.00 149.35
Mezzanine Floor Sqm 0.00 1.00 0.00
Ground Floor Sqm 0.00 1.00 0.00
First Floor Sqm 0.00 1.00 0.00
Second Floor Sqm 0.00 1.00 0.00
Third Floor Sqm 0.00 1.00 0.00
Fourth Floor Sqm 0.00 1.00 0.00
Total Sqm 149.35 165.00
13.5 LOCATION : TANK
Basement Floor Sqm 0.00 1.00 0.00
Lower Ground Floor Sqm 0.00 1.00 0.00
Mezzanine Floor Sqm 0.00 1.00 0.00
Ground Floor Sqm 0.00 1.00 0.00
First Floor Sqm 0.00 1.00 0.00
Second Floor Sqm 0.00 1.00 0.00
Third Floor Sqm 0.00 1.00 0.00
Fourth Floor Sqm 0.00 1.00 0.00
OHT Floor Sqm 0.00 1.00 0.00
Total Sqm 0.00 0.00
Basement Floor Cum 0.00 1.00 0.00
Lower Ground Floor Cum 95.81 1.00 95.81
Mezzanine Floor Cum 0.00 1.00 0.00
Ground Floor Cum 37.77 1.00 37.77
First Floor Cum 190.29 1.00 190.29
Second Floor Cum 0.00 1.00 0.00
Third Floor Cum 0.00 1.00 0.00
Fourth Floor Cum 0.00 1.00 0.00
Total Cum 323.88 357.00
5 FLOORING WORK
5.1 MANDANA-1 (25MM THICK GRANITE) FLOORING CODE-A12-04 & 1/A14-01
Basement Floor Sqm 0.00 1.00 0.00
Lower Ground Floor Sqm 558.22 1.00 558.22
Mezzanine Floor Sqm 0.00 1.00 0.00
Ground Floor Sqm 628.13 1.00 628.13
First Floor Sqm 472.69 1.00 472.69
Second Floor Sqm 0.00 1.00 0.00
Third Floor Sqm 0.00 1.00 0.00
Fourth Floor Sqm 0.00 1.00 0.00
Total Sqm 1659.04 1742.00
5.2 T.W WOOD PLANKS 25MM (SOLID WOOD FLOOR) CODE-A12-04 & 5/A14-01
Basement Floor Sqm 0.00 1.00 0.00
Lower Ground Floor Sqm 0.00 1.00 0.00
Mezzanine Floor Sqm 0.00 1.00 0.00
Ground Floor Sqm 393.34 1.00 393.34
First Floor Sqm 194.14 1.00 194.14
Second Floor Sqm 0.00 1.00 0.00
Third Floor Sqm 0.00 1.00 0.00
Fourth Floor Sqm 0.00 1.00 0.00
Total Sqm 587.48 617.00
5.3 VDF CONCERETE FLOORING CODE-A12-04 & 2/A14-02
Basement Floor Cum 0.00 1.00 0.00
Lower Ground Floor Cum 570.95 1.00 570.95
Mezzanine Floor Cum 0.00 1.00 0.00
Ground Floor Cum 468.66 1.00 468.66
First Floor Cum 597.36 1.00 597.36
Second Floor Cum 0.00 1.00 0.00
Third Floor Cum 0.00 1.00 0.00
Fourth Floor Cum 0.00 1.00 0.00
5.4 25MM THICK SANDSTONE CODE-A12-04 & 1/A14-01
Basement Floor Sqm 0.00 1.00 0.00
Lower Ground Floor Sqm 0.00 1.00 0.00
Mezzanine Floor Sqm 0.00 1.00 0.00
Ground Floor Sqm 30.00 1.00 30.00
First Floor Sqm 33.00 1.00 33.00
Second Floor Sqm 0.00 1.00 0.00
Third Floor Sqm 0.00 1.00 0.00
Fourth Floor Sqm 0.00 1.00 0.00
Total Sqm 63.00 67.00
5.5 25MM THICK STEEL GREY GRANITE FLOORING CODE-A12-04 & 1/A14-01
Basement Floor Sqm 0.00 1.00 0.00
Lower Ground Floor Sqm 69.46 1.00 69.46
Mezzanine Floor Sqm 0.00 1.00 0.00
Ground Floor Sqm 66.24 1.00 66.24
First Floor Sqm 21.96 1.00 21.96
Second Floor Sqm 0.00 1.00 0.00
Third Floor Sqm 0.00 1.00 0.00
Fourth Floor Sqm 0.00 1.00 0.00
Total Sqm 157.65 166.00
5.6 WOODEN DECK CODE-A12-04 & 12/A14-01
Basement Floor Sqm 0.00 1.00 0.00
Lower Ground Floor Sqm 0.00 1.00 0.00
Mezzanine Floor Sqm 0.00 1.00 0.00
Ground Floor Sqm 0.00 1.00 0.00
First Floor Sqm 96.55 1.00 96.55
Second Floor Sqm 0.00 1.00 0.00
Third Floor Sqm 0.00 1.00 0.00
Fourth Floor Sqm 0.00 1.00 0.00
Total Sqm 96.55 102.00
5.7 MANDANA-2 (25MM THICK GRANITE) FLOORING CODE-A12-04 & 1/A14-01
Basement Floor Sqm 0.00 1.00 0.00
Lower Ground Floor Sqm 0.00 1.00 0.00
Mezzanine Floor Sqm 0.00 1.00 0.00
Ground Floor Sqm 115.26 1.00 115.26
First Floor Sqm 0.00 1.00 0.00
Second Floor Sqm 0.00 1.00 0.00
Third Floor Sqm 0.00 1.00 0.00
Fourth Floor Sqm 0.00 1.00 0.00
Total Sqm 115.26 122.00
5.8 RUBBER TILE FLOORING CODE-A12-04 & 3/A14-01
Basement Floor Sqm 0.00 1.00 0.00
Lower Ground Floor Sqm 0.00 1.00 0.00
Mezzanine Floor Sqm 0.00 1.00 0.00
Ground Floor Sqm 0.00 1.00 0.00
First Floor Sqm 0.00 1.00 0.00
Second Floor Sqm 0.00 1.00 0.00
Third Floor Sqm 0.00 1.00 0.00
Fourth Floor Sqm 0.00 1.00 0.00
Total Sqm 0.00 0.00
5.9 S.S WALK OF MATT CODE-A12-04 & 8/A14-01
Basement Floor Sqm 0.00 1.00 0.00
Lower Ground Floor Sqm 10.91 1.00 10.91
Mezzanine Floor Sqm 0.00 1.00 0.00
Ground Floor Sqm 4.32 1.00 4.32
First Floor Sqm 7.50 1.00 7.50
Second Floor Sqm 0.00 1.00 0.00
Third Floor Sqm 0.00 1.00 0.00
Fourth Floor Sqm 0.00 1.00 0.00
Total Sqm 22.73 24.00
6 WALL FINISH WORK
6.1 SANDSTONE CLADDING DRG CODE- A12-05 REF : 6/A14-02
Basement Floor Sqm 0.00 1.00 0.00
Lower Ground Floor Sqm 507.36 1.00 507.36
Mezzanine Floor Sqm 0.00 1.00 0.00
Ground Floor Sqm 1565.84 1.00 1565.84
First Floor Sqm 726.84 1.00 726.84
Second Floor Sqm 0.00 1.00 0.00
Third Floor Sqm 0.00 1.00 0.00
Fourth Floor Sqm 0.00 1.00 0.00
Total Sqm 2800.03 2941.00
6.4 MANDANA STONE-3 CLADDING DRG CODE- A12-05 REF : 6/A14-02
Basement Floor Sqm 0.00 1.00 0.00
Lower Ground Floor Sqm 295.12 1.00 295.12
Mezzanine Floor Sqm 0.00 1.00 0.00
Ground Floor Sqm 421.16 1.00 421.16
First Floor Sqm 119.45 1.00 119.45
Second Floor Sqm 0.00 1.00 0.00
Third Floor Sqm 0.00 1.00 0.00
Fourth Floor Sqm 0.00 1.00 0.00
Total Sqm 835.74 878.00
6.5 GRANITE CLADDING DRG CODE- A12-05 REF : 6/A14-02
Basement Floor Sqm 0.00 1.00 0.00
Lower Ground Floor Sqm 45.32 1.00 45.32
Mezzanine Floor Sqm 0.00 1.00 0.00
Ground Floor Sqm 66.82 1.00 66.82
First Floor Sqm 56.50 1.00 56.50
Second Floor Sqm 0.00 1.00 0.00
Third Floor Sqm 0.00 1.00 0.00
Fourth Floor Sqm 0.00 1.00 0.00
Total Sqm 168.64 178.00
Basement Floor Nos. 0.00 1.00 0.00
Lower Ground Floor Nos. 3317.34 1.00 3317.34
Mezzanine Floor Nos. 0.00 1.00 0.00
Ground Floor Nos. 8106.41 1.00 8106.41
First Floor Nos. 3519.09 1.00 3519.09
Second Floor Nos. 0.00 1.00 0.00
Third Floor Nos. 0.00 1.00 0.00
Fourth Floor Nos. 0.00 1.00 0.00
6.2 FIRE RATED GYPSUM BOARD + PAINT DRG CODE- A12-05 REF : 17/A14-02
Basement Floor Sqm 0.00 1.00 0.00
Lower Ground Floor Sqm 571.13 1.00 571.13
Mezzanine Floor Sqm 0.00 1.00 0.00
Ground Floor Sqm 909.50 1.00 909.50
First Floor Sqm 547.74 1.00 547.74
Second Floor Sqm 0.00 1.00 0.00
Third Floor Sqm 0.00 1.00 0.00
Fourth Floor Sqm 0.00 1.00 0.00
Total Sqm 2028.37 2130.00
6.3 WOODEN PANELING DRG CODE- A12-05 REF : 7/A14-02
Basement Floor Sqm 0.00 1.00 0.00
Lower Ground Floor Sqm 0.00 1.00 0.00
Mezzanine Floor Sqm 0.00 1.00 0.00
Ground Floor Sqm 285.71 1.00 285.71
First Floor Sqm 370.64 1.00 370.64
Second Floor Sqm 0.00 1.00 0.00
Third Floor Sqm 0.00 1.00 0.00
Fourth Floor Sqm 0.00 1.00 0.00
Total Sqm 656.35 690.00
6.6 S.S CLADDING DRG CODE- A12-05 REF : 13/A14-02
Basement Floor Sqm 0.00 1.00 0.00
Lower Ground Floor Sqm 0.00 1.00 0.00
Mezzanine Floor Sqm 0.00 1.00 0.00
Ground Floor Sqm 46.08 1.00 46.08
First Floor Sqm 0.00 1.00 0.00
Second Floor Sqm 0.00 1.00 0.00
Third Floor Sqm 0.00 1.00 0.00
Fourth Floor Sqm 0.00 1.00 0.00
Total Sqm 46.08 49.00
> On Circular Column
Basement Floor Sqm 0.00 1.00 0.00
Lower Ground Floor Sqm 0.00 1.00 0.00
Mezzanine Floor Sqm 0.00 1.00 0.00
Ground Floor Sqm 174.29 1.00 174.29
First Floor Sqm 0.00 1.00 0.00
Second Floor Sqm 0.00 1.00 0.00
Third Floor Sqm 0.00 1.00 0.00
Fourth Floor Sqm 0.00 1.00 0.00
Total Sqm 174.29 184.00
6.7 VITRIFIED TILES CLADDING DRG CODE- A12-05 REF : 8/A14-02
Basement Floor Sqm 0.00 1.00 0.00
Lower Ground Floor Sqm 201.68 1.00 201.68
Mezzanine Floor Sqm 0.00 1.00 0.00
Ground Floor Sqm 329.95 1.00 329.95
First Floor Sqm 202.68 1.00 202.68
Second Floor Sqm 0.00 1.00 0.00
Third Floor Sqm 0.00 1.00 0.00
Fourth Floor Sqm 0.00 1.00 0.00
Total Sqm 734.31 772.00
6.8 MIRROR POLISHED GRANITE CLADDING DRG CODE- A12-05 REF : 6/A14-02
Basement Floor Sqm 0.00 1.00 0.00
Lower Ground Floor Sqm 0.00 1.00 0.00
Mezzanine Floor Sqm 0.00 1.00 0.00
Ground Floor Sqm 0.00 1.00 0.00
First Floor Sqm 0.00 1.00 0.00
Second Floor Sqm 0.00 1.00 0.00
Third Floor Sqm 0.00 1.00 0.00
Fourth Floor Sqm 0.00 1.00 0.00
Total Sqm 0.00 0.00
6.9 VENEER CLADDING DRG CODE- A12-05 REF : 16/A14-02
Basement Floor Sqm 0.00 1.00 0.00
Lower Ground Floor Sqm 0.00 1.00 0.00
Mezzanine Floor Sqm 0.00 1.00 0.00
Ground Floor Sqm 0.00 1.00 0.00
First Floor Sqm 0.00 1.00 0.00
Second Floor Sqm 0.00 1.00 0.00
Third Floor Sqm 0.00 1.00 0.00
Fourth Floor Sqm 0.00 1.00 0.00
Total Sqm 0.00 0.00
8 FALSE CEILING WORK
8.1 PUNCHED GYPSUM + ACOUSTIC CODE-A12-07 & 3/A14-04
Basement Floor Sqm 0.00 1.00 0.00
Lower Ground Floor Sqm 95.28 1.00 95.28
Mezzanine Floor Sqm 0.00 1.00 0.00
Ground Floor Sqm 440.64 1.00 440.64
First Floor Sqm 0.00 1.00 0.00
Second Floor Sqm 0.00 1.00 0.00
Third Floor Sqm 0.00 1.00 0.00
Fourth Floor Sqm 0.00 1.00 0.00
Total Sqm 535.92 563.00
8.2 ALUMINUM PANELS CODE-A12-07 & 4/A14-04
Basement Floor Sqm 0.00 1.00 0.00
Lower Ground Floor Sqm 0.00 1.00 0.00
Mezzanine Floor Sqm 0.00 1.00 0.00
Ground Floor Sqm 0.00 1.00 0.00
First Floor Sqm 0.00 1.00 0.00
Second Floor Sqm 0.00 1.00 0.00
Third Floor Sqm 0.00 1.00 0.00
Fourth Floor Sqm 0.00 1.00 0.00
Total Sqm 0.00 0.00
8.3 GYPSUM + ACOUSTIC LINING CODE-A12-07 & 1/A14-04
Basement Floor Sqm 0.00 1.00 0.00
Lower Ground Floor Sqm 548.74 1.00 548.74
Mezzanine Floor Sqm 0.00 1.00 0.00
Ground Floor Sqm 879.56 1.00 879.56
First Floor Sqm 829.71 1.00 829.71
Second Floor Sqm 0.00 1.00 0.00
Third Floor Sqm 0.00 1.00 0.00
Fourth Floor Sqm 0.00 1.00 0.00
Total Sqm 2258.01 2371.00
8.4 (AUDI) GYPSUM + ACOUSTIC CODE-A12-07 & 2A/A14-04
Basement Floor Sqm 0.00 1.00 0.00
Lower Ground Floor Sqm 0.00 1.00 0.00
Mezzanine Floor Sqm 0.00 1.00 0.00
Ground Floor Sqm 0.00 1.00 0.00
First Floor Sqm 0.00 1.00 0.00
Second Floor Sqm 0.00 1.00 0.00
Third Floor Sqm 0.00 1.00 0.00
Fourth Floor Sqm 0.00 1.00 0.00
Total Sqm 0.00 0.00
8.5 WOODEN CEILING CODE-A12-07 & 9/A14-04
Basement Floor Sqm 0.00 1.00 0.00
Lower Ground Floor Sqm 0.00 1.00 0.00
Mezzanine Floor Sqm 0.00 1.00 0.00
Ground Floor Sqm 0.00 1.00 0.00
First Floor Sqm 0.00 1.00 0.00
Second Floor Sqm 0.00 1.00 0.00
Third Floor Sqm 0.00 1.00 0.00
Fourth Floor Sqm 0.00 1.00 0.00
Total Sqm 0.00 0.00
8.6 WOODEN SLATS CODE-A12-07 & 10/A14-04
Basement Floor Sqm 0.00 1.00 0.00
Lower Ground Floor Sqm 0.00 1.00 0.00
Mezzanine Floor Sqm 0.00 1.00 0.00
Ground Floor Sqm 0.00 1.00 0.00
First Floor Sqm 55.27 1.00 55.27
Second Floor Sqm 0.00 1.00 0.00
Third Floor Sqm 0.00 1.00 0.00
Fourth Floor Sqm 0.00 1.00 0.00
Total Sqm 55.27 59.00
8.7 FRP CANOPY CODE-A12-07 & 7/A14-04
Basement Floor Sqm 0.00 1.00 0.00
Lower Ground Floor Sqm 0.00 1.00 0.00
Mezzanine Floor Sqm 0.00 1.00 0.00
Ground Floor Sqm 0.00 1.00 0.00
First Floor Sqm 0.00 1.00 0.00
Second Floor Sqm 0.00 1.00 0.00
Third Floor Sqm 0.00 1.00 0.00
Fourth Floor Sqm 0.00 1.00 0.00
Total Sqm 0.00 0.00
8.8 ALUMINIUM GRILL CODE-A12-07 & 22/A14-04
Basement Floor Sqm 0.00 1.00 0.00
Lower Ground Floor Sqm 0.00 1.00 0.00
Mezzanine Floor Sqm 0.00 1.00 0.00
Ground Floor Sqm 0.00 1.00 0.00
First Floor Sqm 0.00 1.00 0.00
Second Floor Sqm 0.00 1.00 0.00
Third Floor Sqm 0.00 1.00 0.00
Fourth Floor Sqm 0.00 1.00 0.00
Total Sqm 0.00 0.00
5.10 25MM THICK KOTA STONE FLOORING CODE-A12-04 & 4/A14-01
Basement Floor Sqm 0.00 1.00 0.00
Lower Ground Floor Sqm 168.62 1.00 168.62
Mezzanine Floor Sqm 0.00 1.00 0.00
Ground Floor Sqm 129.19 1.00 129.19
First Floor Sqm 332.12 1.00 332.12
Second Floor Sqm 0.00 1.00 0.00
Third Floor Sqm 0.00 1.00 0.00
Fourth Floor Sqm 0.00 1.00 0.00
Total Sqm 629.93 662.00
5.11 SEALED CONCRETE FLOORING CODE-A12-04 & 13/A14-01
Basement Floor Cum 0.00 1.00 0.00
Lower Ground Floor Cum 78.62 1.00 78.62
Mezzanine Floor Cum 0.00 1.00 0.00
Ground Floor Cum 0.00 1.00 0.00
First Floor Cum 0.00 1.00 0.00
Second Floor Cum 0.00 1.00 0.00
Third Floor Cum 0.00 1.00 0.00
Fourth Floor Cum 0.00 1.00 0.00
Total Cum 0.10 7.86 9.00
5.12 G.I WALK OF MATT CODE-A12-04 & 8/A14-01
Basement Floor Sqm 0.00 1.00 0.00
Lower Ground Floor Sqm 0.00 1.00 0.00
Mezzanine Floor Sqm 0.00 1.00 0.00
Ground Floor Sqm 0.00 1.00 0.00
First Floor Sqm 0.00 1.00 0.00
Second Floor Sqm 0.00 1.00 0.00
Third Floor Sqm 0.00 1.00 0.00
Fourth Floor Sqm 0.00 1.00 0.00
Total Sqm 0.00 0.00
5.13 GRATING CODE-A12-04 & 6/A14-01
Basement Floor Sqm 0.00 1.00 0.00
Lower Ground Floor Sqm 0.00 1.00 0.00
Mezzanine Floor Sqm 0.00 1.00 0.00
Ground Floor Sqm 0.00 1.00 0.00
First Floor Sqm 0.00 1.00 0.00
Second Floor Sqm 0.00 1.00 0.00
Third Floor Sqm 0.00 1.00 0.00
Fourth Floor Sqm 0.00 1.00 0.00
Total Sqm 0.00 0.00
5.14 8MM THICK WHITE GLAZED TILES CODE-A12-04 & 11/A14-01
Basement Floor Sqm 0.00 1.00 0.00
Lower Ground Floor Sqm 0.00 1.00 0.00
Mezzanine Floor Sqm 0.00 1.00 0.00
Ground Floor Sqm 0.00 1.00 0.00
First Floor Sqm 0.00 1.00 0.00
Second Floor Sqm 0.00 1.00 0.00
Third Floor Sqm 0.00 1.00 0.00
Fourth Floor Sqm 0.00 1.00 0.00
Total Sqm 0.00 0.00
5.15 10 MM THICK VITRIFIED TILES FLOORING CODE-A12-04 & 7/A14-01
Basement Floor Sqm 0.00 1.00 0.00
Lower Ground Floor Sqm 0.00 1.00 0.00
Mezzanine Floor Sqm 0.00 1.00 0.00
Ground Floor Sqm 0.00 1.00 0.00
First Floor Sqm 0.00 1.00 0.00
Second Floor Sqm 0.00 1.00 0.00
Third Floor Sqm 0.00 1.00 0.00
Fourth Floor Sqm 0.00 1.00 0.00
Total Sqm 0.00 0.00
5.16 RAISED ANTI-STATIC FLOORING CODE-A12-04 & 9/A14-01
Basement Floor Sqm 0.00 1.00 0.00
Lower Ground Floor Sqm 0.00 1.00 0.00
Mezzanine Floor Sqm 0.00 1.00 0.00
Ground Floor Sqm 0.00 1.00 0.00
First Floor Sqm 0.00 1.00 0.00
Second Floor Sqm 0.00 1.00 0.00
Third Floor Sqm 0.00 1.00 0.00
Fourth Floor Sqm 0.00 1.00 0.00
Total Sqm 0.00 0.00
5.17 CARPET TILE FLOORING CODE-A12-04 & 10/A14-01
Basement Floor Sqm 0.00 1.00 0.00
Lower Ground Floor Sqm 0.00 1.00 0.00
Mezzanine Floor Sqm 0.00 1.00 0.00
Ground Floor Sqm 0.00 1.00 0.00
First Floor Sqm 0.00 1.00 0.00
Second Floor Sqm 0.00 1.00 0.00
Third Floor Sqm 0.00 1.00 0.00
Fourth Floor Sqm 0.00 1.00 0.00
Total Sqm 0.00 0.00
5.18 25 MM THICK GRAY GRANITE FLOORING CODE-A12-04 & 1/A14-01
Basement Floor Sqm 0.00 1.00 0.00
Lower Ground Floor Sqm 160.72 1.00 160.72
Mezzanine Floor Sqm 0.00 1.00 0.00
Ground Floor Sqm 0.00 1.00 0.00
First Floor Sqm 0.00 1.00 0.00
Second Floor Sqm 0.00 1.00 0.00
Third Floor Sqm 0.00 1.00 0.00
Fourth Floor Sqm 0.00 1.00 0.00
Total Sqm 160.72 169.00
5.19 GRANITE+STONE DECK FLOORING CODE-A12-04 & 14/A14-01
Basement Floor Sqm 0.00 1.00 0.00
Lower Ground Floor Sqm 0.00 1.00 0.00
Mezzanine Floor Sqm 0.00 1.00 0.00
Ground Floor Sqm 0.00 1.00 0.00
First Floor Sqm 0.00 1.00 0.00
Second Floor Sqm 0.00 1.00 0.00 show mesurement sheet
Third Floor Sqm 0.00 1.00 0.00
Fourth Floor Sqm 0.00 1.00 0.00
Total Sqm 0.00 0.00
5.20 25MM THICK KOTA STONE FLOORING CODE-A12-04 & 4/A14-01 (LOCATION : Staircase)
Basement Floor Sqm 0.00 1.00 0.00
Lower Ground Floor Sqm 139.10 1.00 139.10
Mezzanine Floor Sqm 0.00 1.00 0.00
Ground Floor Sqm 80.11 1.00 80.11
First Floor Sqm 46.40 1.00 46.40
Second Floor Sqm 10.27 1.00 10.27
Third Floor Sqm 0.00 1.00 0.00
Fourth Floor Sqm 0.00 1.00 0.00
Total Sqm 275.88 290.00
5.20 MANDANA-1 (25MM THICK GRANITE) STAIRCASE FLOORING CODE-A12-04 & 1/A14-01
Basement Floor Sqm 0.00 1.00 0.00
Lower Ground Floor Sqm 19.52 1.00 19.52
Mezzanine Floor Sqm 0.00 1.00 0.00
Ground Floor Sqm 11.25 1.00 11.25
First Floor Sqm 0.00 1.00 0.00
Second Floor Sqm 0.00 1.00 0.00
Third Floor Sqm 0.00 1.00 0.00
Fourth Floor Sqm 0.00 1.00 0.00
Total Sqm 30.77 33.00
5.21 25MM THICK KOTA STONE-TREADS CODE-A12-04 & 4/A14-01 (LOCATION : Staircase)
Basement Floor Rmt 0.00 1.00 0.00
Lower Ground Floor Rmt 170.00 1.00 170.00
Mezzanine Floor Rmt 0.00 1.00 0.00
Ground Floor Rmt 170.00 1.00 170.00
First Floor Rmt 76.00 1.00 76.00
Second Floor Rmt 0.00 1.00 0.00
Third Floor Rmt 0.00 1.00 0.00
Fourth Floor Rmt 0.00 1.00 0.00
Total Rmt 416.00 437.00
5.22 MANDANA-1 (25MM THICK GRANITE) TREADS CODE-A12-04 & 1/A14-01
Basement Floor Rmt 0.00 1.00 0.00
Lower Ground Floor Rmt 119.70 1.00 119.70
Mezzanine Floor Rmt 0.00 1.00 0.00
Ground Floor Rmt 49.50 1.00 49.50
First Floor Rmt 0.00 1.00 0.00
Second Floor Rmt 0.00 1.00 0.00
Third Floor Rmt 0.00 1.00 0.00
Fourth Floor Rmt 0.00 1.00 0.00
Total Rmt 169.20 178.00
Total Sqm 0.30 50.76 54.00
5.23 25MM THICK KOTA STONE-RISERS CODE-A12-04 & 4/A14-01 (LOCATION : Staircase)
Basement Floor Rmt 0.00 1.00 0.00
Lower Ground Floor Rmt 192.00 1.00 192.00
Mezzanine Floor Rmt 0.00 1.00 0.00
Ground Floor Rmt 192.00 1.00 192.00
First Floor Rmt 84.00 1.00 84.00
Second Floor Rmt 0.00 1.00 0.00
Third Floor Rmt 0.00 1.00 0.00
Fourth Floor Rmt 0.00 1.00 0.00
Total Rmt 468.00 492.00
Total Sqm 0.15 70.20 74.00
5.22 450 MM WIDE MANDANA-1 (25MM THICK GRANITE) TREADS CODE-A12-04 & 1/A14-01
Basement Floor Sqm 0.00 1.00 0.00
Lower Ground Floor Sqm 0.00 1.00 0.00
Mezzanine Floor Sqm 0.00 1.00 0.00
Ground Floor Sqm 30.38 1.00 30.38
First Floor Sqm 0.00 1.00 0.00
Second Floor Sqm 0.00 1.00 0.00
Third Floor Sqm 0.00 1.00 0.00
Fourth Floor Sqm 0.00 1.00 0.00
Total Sqm 30.38 32.00
5.22 450 MM WIDE MANDANA-1 (25MM THICK GRANITE) RISERS CODE-A12-04 & 1/A14-01
Basement Floor Sqm 0.00 1.00 0.00
Lower Ground Floor Sqm 0.00 1.00 0.00
Mezzanine Floor Sqm 0.00 1.00 0.00
Ground Floor Sqm 6.75 1.00 6.75
First Floor Sqm 0.00 1.00 0.00
Second Floor Sqm 0.00 1.00 0.00
Third Floor Sqm 0.00 1.00 0.00
Fourth Floor Sqm 0.00 1.00 0.00
Total Sqm 6.75 8.00
5.24 MANDANA-1 (25MM THICK GRANITE) RISERS CODE-A12-04 & 1/A14-01
Basement Floor Rmt 0.00 1.00 0.00
Lower Ground Floor Rmt 129.60 1.00 129.60
Mezzanine Floor Rmt 0.00 1.00 0.00
Ground Floor Rmt 54.00 1.00 54.00
First Floor Rmt 0.00 1.00 0.00
Second Floor Rmt 0.00 1.00 0.00
Third Floor Rmt 0.00 1.00 0.00
Fourth Floor Rmt 0.00 1.00 0.00
Total Rmt 183.60 193.00
Total Sqm 0.15 27.54 29.00
5.23 25MM THICK KOTA STONE-SKIRTING CODE-A12-04 & 4/A14-01 (LOCATION : Staircase)
Basement Floor Rmt 0.00 1.00 0.00
Lower Ground Floor Rmt 125.34 1.00 125.34
Mezzanine Floor Rmt 0.00 1.00 0.00
Ground Floor Rmt 77.15 1.00 77.15
First Floor Rmt 43.82 1.00 43.82
Second Floor Rmt 8.60 1.00 8.60
Third Floor Rmt 0.00 1.00 0.00
Fourth Floor Rmt 0.00 1.00 0.00
Total Rmt 254.91 268.00
Total Sqm 0.10 25.49 27.00
5.24 25MM THICK KOTA STONE-INCLINED SKIRTING CODE-A12-04 & 4/A14-01 (LOCATION : Staircase)
Basement Floor Rmt 0.00 1.00 0.00
Lower Ground Floor Rmt 29.29 1.00 29.29
Mezzanine Floor Rmt 0.00 1.00 0.00
Ground Floor Rmt 29.29 1.00 29.29
First Floor Rmt 13.03 1.00 13.03
Second Floor Rmt 0.00 1.00 0.00
Third Floor Rmt 0.00 1.00 0.00
Fourth Floor Rmt 0.00 1.00 0.00
Total Rmt 71.61 76.00
Total Sqm 0.10 7.16 8.00
5.23 MANDANA-1 (25MM THICK GRANITE) STAIRCASE SKIRTING CODE-A12-04 & 1/A14-01
Basement Floor Rmt 0.00 1.00 0.00
Lower Ground Floor Rmt 8.08 1.00 8.08
Mezzanine Floor Rmt 0.00 1.00 0.00
Ground Floor Rmt 0.00 1.00 0.00
First Floor Rmt 0.00 1.00 0.00
Second Floor Rmt 0.00 1.00 0.00
Third Floor Rmt 0.00 1.00 0.00
Fourth Floor Rmt 0.00 1.00 0.00
Total Rmt 0.00 0.00
Total Sqm 0.10 0.00 0.00
5.24 MANDANA-1 (25MM THICK GRANITE) STAIRCASE INCLINED SKIRTING CODE-A12-04 & 1/A14-01
Basement Floor Rmt 0.00 1.00 0.00
Lower Ground Floor Rmt 0.00 1.00 0.00
Mezzanine Floor Rmt 13.29 1.00 13.29
Ground Floor Rmt 0.00 1.00 0.00
First Floor Rmt 0.00 1.00 0.00
Second Floor Rmt 0.00 1.00 0.00
Third Floor Rmt 0.00 1.00 0.00
Fourth Floor Rmt 0.00 1.00 0.00
Total Rmt 0.00 0.00
Total Sqm 0.10 0.00 0.00
6.10 VITRIFIED TILES-2 CLADDING DRG CODE- A12-05 REF : 8/A14-02
Basement Floor Sqm 0.00 1.00 0.00
Lower Ground Floor Sqm 0.00 1.00 0.00
Mezzanine Floor Sqm 0.00 1.00 0.00
Ground Floor Sqm 0.00 1.00 0.00
First Floor Sqm 0.00 1.00 0.00
Second Floor Sqm 0.00 1.00 0.00
Third Floor Sqm 0.00 1.00 0.00
Fourth Floor Sqm 0.00 1.00 0.00
Total Sqm 0.00 0.00
6.11 GYPSUM PLASTER + PAINT DRG CODE- A12-05 REF : 10/A14-02
Basement Floor Sqm 0.00 1.00 0.00
Lower Ground Floor Sqm 1253.11 1.00 1253.11
Mezzanine Floor Sqm 0.00 1.00 0.00
Ground Floor Sqm 628.56 1.00 628.56
First Floor Sqm 663.34 1.00 663.34
Second Floor Sqm 0.00 1.00 0.00
Third Floor Sqm 0.00 1.00 0.00
Fourth Floor Sqm 0.00 1.00 0.00
Total Sqm 2545.01 2673.00
6.12 GYPSUM PARTITION WALL SYSTEM DRG CODE- A12-05 REF : 9/A14-02
Basement Floor Sqm 0.00 1.00 0.00
Lower Ground Floor Sqm 0.00 1.00 0.00
Mezzanine Floor Sqm 0.00 1.00 0.00
Ground Floor Sqm 0.00 1.00 0.00
First Floor Sqm 0.00 1.00 0.00
Second Floor Sqm 0.00 1.00 0.00
Third Floor Sqm 0.00 1.00 0.00
Fourth Floor Sqm 0.00 1.00 0.00
Total Sqm 0.00 0.00
6.13 SOUND ATTENAUTION DRG CODE- A12-05 REF : 11/A14-02
Basement Floor Sqm 0.00 1.00 0.00
Lower Ground Floor Sqm 174.78 1.00 174.78
Mezzanine Floor Sqm 0.00 1.00 0.00
Ground Floor Sqm 55.08 1.00 55.08
First Floor Sqm 305.14 1.00 305.14
Second Floor Sqm 0.00 1.00 0.00
Third Floor Sqm 0.00 1.00 0.00
Fourth Floor Sqm 0.00 1.00 0.00
Total Sqm 534.99 562.00
6.14 WHITE GLAZED VITRIFIED TILES CLADDING DRG CODE- A12-05 REF : 8/A14-02
Basement Floor Sqm 0.00 1.00 0.00
Lower Ground Floor Sqm 0.00 1.00 0.00
Mezzanine Floor Sqm 0.00 1.00 0.00
Ground Floor Sqm 0.00 1.00 0.00
First Floor Sqm 0.00 1.00 0.00
Second Floor Sqm 0.00 1.00 0.00
Third Floor Sqm 0.00 1.00 0.00
Fourth Floor Sqm 0.00 1.00 0.00
Total Sqm 0.00 0.00
6.15 PLASTER + PAINT DRG CODE- A12-05 REF : 14/A14-02
Basement Floor Sqm 0.00 1.00 0.00
Lower Ground Floor Sqm 0.00 1.00 0.00
Mezzanine Floor Sqm 0.00 1.00 0.00
Ground Floor Sqm 0.00 1.00 0.00
First Floor Sqm 0.00 1.00 0.00
Second Floor Sqm 0.00 1.00 0.00
Third Floor Sqm 0.00 1.00 0.00
Fourth Floor Sqm 0.00 1.00 0.00
Total Sqm 0.00 0.00
6.16 PLASTER FINISH DRG CODE- A12-05 REF : 15/A14-02
Basement Floor Sqm 0.00 1.00 0.00
Lower Ground Floor Sqm 817.55 1.00 817.55
Mezzanine Floor Sqm 0.00 1.00 0.00
Ground Floor Sqm 525.20 1.00 525.20
First Floor Sqm 616.91 1.00 616.91
Second Floor Sqm 0.00 1.00 0.00
Third Floor Sqm 0.00 1.00 0.00
Fourth Floor Sqm 0.00 1.00 0.00
Total Sqm 1959.66 2058.00
6.17 ALUMINIUM CLADDING DRG CODE- A12-05 REF : 12/A14-02
Basement Floor Sqm 0.00 1.00 0.00
Lower Ground Floor Sqm 0.00 1.00 0.00
Mezzanine Floor Sqm 0.00 1.00 0.00
Ground Floor Sqm 33.60 1.00 33.60
First Floor Sqm 0.00 1.00 0.00
Second Floor Sqm 0.00 1.00 0.00
Third Floor Sqm 0.00 1.00 0.00
Fourth Floor Sqm 0.00 1.00 0.00
Total Sqm 33.60 36.00
7 SKIRTING WORK
7.1 WOODEN SKIRTING CODE-A12-06 & 3/A14-03
Basement Floor Rmt 0.00 1.00 0.00
Lower Ground Floor Rmt 40.20 1.00 40.20
Mezzanine Floor Rmt 0.00 1.00 0.00
Ground Floor Rmt 0.00 1.00 0.00
First Floor Rmt 0.00 1.00 0.00
Second Floor Rmt 0.00 1.00 0.00
Third Floor Rmt 0.00 1.00 0.00
Fourth Floor Rmt 0.00 1.00 0.00
Total Rmt 40.20 43.00
7.2 KOTA STONE SKIRTING (LOADING BAY) CODE-A12-06 & 2/A14-03
Basement Floor Rmt 0.00 1.00 0.00
Lower Ground Floor Rmt 32.65 1.00 32.65
Mezzanine Floor Rmt 0.00 1.00 0.00
Ground Floor Rmt 0.00 1.00 0.00
First Floor Rmt 0.00 1.00 0.00
Second Floor Rmt 0.00 1.00 0.00
Third Floor Rmt 0.00 1.00 0.00
Fourth Floor Rmt 0.00 1.00 0.00
Total Rmt 32.65 35.00
7.3 KOTA STONE SKIRTING CODE-A12-06 & 1/A14-03
Basement Floor Rmt 0.00 1.00 0.00
Lower Ground Floor Rmt 189.15 1.00 189.15
Mezzanine Floor Rmt 0.00 1.00 0.00
Ground Floor Rmt 54.06 1.00 54.06
First Floor Rmt 164.66 1.00 164.66
Second Floor Rmt 0.00 1.00 0.00
Third Floor Rmt 0.00 1.00 0.00
Fourth Floor Rmt 0.00 1.00 0.00
Total Rmt 407.88 429.00
7.4 S.S BASE (COLUMN) CODE-A12-06 & 4/A14-03
Basement Floor Rmt 0.00 1.00 0.00
Lower Ground Floor Rmt 0.00 1.00 0.00
Mezzanine Floor Rmt 0.00 1.00 0.00
Ground Floor Rmt 0.00 1.00 0.00
First Floor Rmt 0.00 1.00 0.00
Second Floor Rmt 0.00 1.00 0.00
Third Floor Rmt 0.00 1.00 0.00
Fourth Floor Rmt 0.00 1.00 0.00
Total Rmt 0.00 0.00
8 FALSE CEILING WORK
8.9 MINERAL FIBRE GRID CEILING 600X600 CODE-A12-07 & 2/A14-04
Basement Floor Sqm 0.00 1.00 0.00
Lower Ground Floor Sqm 115.12 1.00 115.12
Mezzanine Floor Sqm 0.00 1.00 0.00
Ground Floor Sqm 96.99 1.00 96.99
First Floor Sqm 116.48 1.00 116.48
Second Floor Sqm 0.00 1.00 0.00
Third Floor Sqm 0.00 1.00 0.00
Fourth Floor Sqm 0.00 1.00 0.00
Total Sqm 328.59 346.00
8.10 GYPSUM + PAINT CODE-A12-07 & 5/A14-04
Basement Floor Sqm 0.00 1.00 0.00
Lower Ground Floor Sqm 54.78 1.00 54.78
Mezzanine Floor Sqm 0.00 1.00 0.00
Ground Floor Sqm 64.89 1.00 64.89
First Floor Sqm 21.10 1.00 21.10
Second Floor Sqm 0.00 1.00 0.00
Third Floor Sqm 0.00 1.00 0.00
Fourth Floor Sqm 0.00 1.00 0.00
Total Sqm 140.76 148.00
8.11 PLASTER FINISH CODE-A12-07
Basement Floor Sqm 0.00 1.00 0.00
Lower Ground Floor Sqm 0.00 1.00 0.00
Mezzanine Floor Sqm 0.00 1.00 0.00
Ground Floor Sqm 0.00 1.00 0.00
First Floor Sqm 0.00 1.00 0.00
Second Floor Sqm 0.00 1.00 0.00
Third Floor Sqm 0.00 1.00 0.00
Fourth Floor Sqm 0.00 1.00 0.00
Total Sqm 0.00 0.00
8.12 METAL CEILING CODE-A12-07 & 11/A14-04
Basement Floor Sqm 0.00 1.00 0.00
Lower Ground Floor Sqm 0.00 1.00 0.00
Mezzanine Floor Sqm 0.00 1.00 0.00
Ground Floor Sqm 0.00 1.00 0.00
First Floor Sqm 32.19 1.00 32.19
Second Floor Sqm 0.00 1.00 0.00
Third Floor Sqm 0.00 1.00 0.00
Fourth Floor Sqm 0.00 1.00 0.00
Total Sqm 32.19 34.00
8.13 PLASTER + PAINT CODE-A12-07 & 5/A14-04
Basement Floor Sqm 0.00 1.00 0.00
Lower Ground Floor Sqm 36.25 1.00 36.25
Mezzanine Floor Sqm 0.00 1.00 0.00
Ground Floor Sqm 0.00 1.00 0.00
First Floor Sqm 14.51 1.00 14.51
Second Floor Sqm 0.00 1.00 0.00
Third Floor Sqm 0.00 1.00 0.00
Fourth Floor Sqm 0.00 1.00 0.00
Total Sqm 50.76 54.00
8.14 SOUND ATTENUATION CODE-A12-07 & 8/A14-04
Basement Floor Sqm 0.00 1.00 0.00
Lower Ground Floor Sqm 78.83 1.00 78.83
Mezzanine Floor Sqm 0.00 1.00 0.00
Ground Floor Sqm 25.71 1.00 25.71
First Floor Sqm 147.04 1.00 147.04
Second Floor Sqm 0.00 1.00 0.00
Third Floor Sqm 0.00 1.00 0.00
Fourth Floor Sqm 0.00 1.00 0.00
Total Sqm 251.58 265.00
8.15 M.R GRADE GYPSUM GRID 600X600 CODE-A12-07 & 7/A14-04
Basement Floor Sqm 0.00 1.00 0.00
Lower Ground Floor Sqm 0.00 1.00 0.00
Mezzanine Floor Sqm 0.00 1.00 0.00
Ground Floor Sqm 0.00 1.00 0.00
First Floor Sqm 0.00 1.00 0.00
Second Floor Sqm 0.00 1.00 0.00
Third Floor Sqm 0.00 1.00 0.00
Fourth Floor Sqm 0.00 1.00 0.00
Total Sqm 0.00 0.00
8.16 BARRIOL CEILING CODE-A12-07 & 20/A14-04
Basement Floor Sqm 0.00 1.00 0.00
Lower Ground Floor Sqm 0.00 1.00 0.00
Mezzanine Floor Sqm 0.00 1.00 0.00
Ground Floor Sqm 0.00 1.00 0.00
First Floor Sqm 8.56 1.00 8.56
Second Floor Sqm 0.00 1.00 0.00
Third Floor Sqm 0.00 1.00 0.00
Fourth Floor Sqm 0.00 1.00 0.00
Total Sqm 8.56 9.00
14.8 GRANITE COUNTER
Basement Floor Sqm 0.00 1.00 0.00
Lower Ground Floor Sqm 4.14 1.00 4.14
Mezzanine Floor Sqm 0.00 1.00 0.00
Ground Floor Sqm 7.67 1.00 7.67
First Floor Sqm 3.51 1.00 3.51
Second Floor Sqm 3.05 1.00 3.05
Third Floor Sqm 0.00 1.00 0.00
Fourth Floor Sqm 0.00 1.00 0.00
Total Sqm 18.36 20.00
14.9 FACIA - GRANITE
Basement Floor Sqm 0.00 1.00 0.00
Lower Ground Floor Sqm 5.40 1.00 5.40
Mezzanine Floor Sqm 0.00 1.00 0.00
Ground Floor Sqm 12.00 1.00 12.00
First Floor Sqm 5.40 1.00 5.40
Second Floor Sqm 4.68 1.00 4.68
Third Floor Sqm 0.00 1.00 0.00
Fourth Floor Sqm 0.00 1.00 0.00
Total Sqm 27.49 29.00
14.1 SINK NUMBER
Basement Floor Nos 0.00 1.00 0.00
Lower Ground Floor Nos 6.00 1.00 6.00
Mezzanine Floor Nos 0.00 1.00 0.00
Ground Floor Nos 12.00 1.00 12.00
First Floor Nos 6.00 1.00 6.00
Second Floor Nos 4.00 1.00 4.00
Third Floor Nos 0.00 1.00 0.00
Fourth Floor Nos 0.00 1.00 0.00
Total Nos 28.00 28.00
1 CUBICLES-L shape
Basement Floor Nos 0.00 1.00 0.00
Lower Ground Floor Nos 7.00 1.00 7.00
Mezzanine Floor Nos 0.00 1.00 0.00
Ground Floor Nos 5.00 1.00 5.00
First Floor Nos 1.00 1.00 1.00
Second Floor Nos 0.00 1.00 0.00
Third Floor Nos 0.00 1.00 0.00
Fourth Floor Nos 0.00 1.00 0.00
Total Nos 13.00 13.00
1 CUBICLES-I shape
Basement Floor Nos 0.00 1.00 0.00
Lower Ground Floor Nos 2.00 1.00 2.00
Mezzanine Floor Nos 0.00 1.00 0.00
Ground Floor Nos 5.00 1.00 5.00
First Floor Nos 2.00 1.00 2.00
Second Floor Nos 0.00 1.00 0.00
Third Floor Nos 0.00 1.00 0.00
Fourth Floor Nos 0.00 1.00 0.00
Total Nos 9.00 9.00
2 URINAL PARTITION
Basement Floor Sqm 0.00 1.00 0.00
Lower Ground Floor Sqm 1.20 1.00 1.20
Mezzanine Floor Sqm 0.00 1.00 0.00
Ground Floor Sqm 0.90 1.00 0.90
First Floor Sqm 0.30 1.00 0.30
Second Floor Sqm 0.00 1.00 0.00
Third Floor Sqm 0.00 1.00 0.00
Fourth Floor Sqm 0.00 1.00 0.00
Total Sqm 2.40 3.00
9 PARAPET FINISH
9.1 2 SIDE PLASTER CODE-A12-08 & 4/A11-01
Basement Floor Sqm 0.00 1.00 0.00
Lower Ground Floor Sqm 0.00 1.00 0.00
Mezzanine Floor Sqm 0.00 1.00 0.00
Ground Floor Sqm 0.00 1.00 0.00
First Floor Sqm 0.00 1.00 0.00
Second Floor Sqm 0.00 1.00 0.00
Third Floor Sqm 0.00 1.00 0.00
Fourth Floor Sqm 0.00 1.00 0.00
Roof Floor Sqm 85.61 1.00 85.61
Total Sqm 85.61 90.00
9.2 1SIDE STONE CLADDING CODE-A12-08 & 1/A11-01
Basement Floor Sqm 0.00 1.00 0.00
Lower Ground Floor Sqm 42.16 1.00 42.16
Mezzanine Floor Sqm 0.00 1.00 0.00
Ground Floor Sqm 0.00 1.00 0.00
First Floor Sqm 19.67 1.00 19.67
Second Floor Sqm 0.00 1.00 0.00
Third Floor Sqm 0.00 1.00 0.00
Fourth Floor Sqm 0.00 1.00 0.00
Roof Floor Sqm 181.60 1.00 181.60
Total Sqm 243.43 256.00
9.3 EXTENDED CLADDING CODE-A12-08 & 2/A11-01
Basement Floor Sqm 0.00 1.00 0.00
Lower Ground Floor Sqm 0.00 1.00 0.00
Mezzanine Floor Sqm 0.00 1.00 0.00
Ground Floor Sqm 0.00 1.00 0.00
First Floor Sqm 0.00 1.00 0.00
Second Floor Sqm 0.00 1.00 0.00
Third Floor Sqm 0.00 1.00 0.00
Fourth Floor Sqm 0.00 1.00 0.00
Roof Floor Sqm 85.45 1.00 85.45
Total Sqm 85.45 90.00
9.4 2 SIDE STONE CLADDING CODE-A12-08 & 3/A11-01
Basement Floor Sqm 0.00 1.00 0.00
Lower Ground Floor Sqm 0.00 1.00 0.00
Mezzanine Floor Sqm 0.00 1.00 0.00
Ground Floor Sqm 0.00 1.00 0.00
First Floor Sqm 0.00 1.00 0.00
Second Floor Sqm 0.00 1.00 0.00
Third Floor Sqm 0.00 1.00 0.00
Fourth Floor Sqm 0.00 1.00 0.00
Roof Floor Sqm 111.12 1.00 111.12
Total Sqm 111.12 117.00
9.5 S.S CLADDING CODE-A12-08 & 5/A11-01
Basement Floor Sqm 0.00 1.00 0.00
Lower Ground Floor Sqm 0.00 1.00 0.00
Mezzanine Floor Sqm 0.00 1.00 0.00
Ground Floor Sqm 0.00 1.00 0.00
First Floor Sqm 0.00 1.00 0.00
Second Floor Sqm 0.00 1.00 0.00
Third Floor Sqm 0.00 1.00 0.00
Fourth Floor Sqm 0.00 1.00 0.00
Roof Floor Sqm 33.85 1.00 33.85
Total Sqm 33.85 36.00
9.6 WET CLADDING CODE-A12-08 & 6/A11-01
Basement Floor Sqm 0.00 1.00 0.00
Lower Ground Floor Sqm 0.00 1.00 0.00
Mezzanine Floor Sqm 0.00 1.00 0.00
Ground Floor Sqm 0.00 1.00 0.00
First Floor Sqm 0.00 1.00 0.00
Second Floor Sqm 0.00 1.00 0.00
Third Floor Sqm 0.00 1.00 0.00
Fourth Floor Sqm 0.00 1.00 0.00
Total Sqm 0.00 0.00
10 FLASHING TYPE
10.1 FLASHING TYPE 1 CODE-A12-08 & 5/A11-01
Basement Floor Rmt 0.00 1.00 0.00
Lower Ground Floor Rmt 0.00 1.00 0.00
Mezzanine Floor Rmt 0.00 1.00 0.00
Ground Floor Rmt 0.00 1.00 0.00
First Floor Rmt 31.22 1.00 31.22
Second Floor Rmt 0.00 1.00 0.00
Third Floor Rmt 0.00 1.00 0.00
Fourth Floor Rmt 0.00 1.00 0.00
Roof Floor Rmt 47.83 1.00 47.83
Total Rmt 79.04 83.00
10.2 FLASHING TYPE 2 CODE-A12-08 & 6/A11-01
Basement Floor Rmt 0.00 1.00 0.00
Lower Ground Floor Rmt 0.00 1.00 0.00
Mezzanine Floor Rmt 0.00 1.00 0.00
Ground Floor Rmt 0.00 1.00 0.00
First Floor Rmt 0.00 1.00 0.00
Second Floor Rmt 0.00 1.00 0.00
Third Floor Rmt 0.00 1.00 0.00
Fourth Floor Rmt 0.00 1.00 0.00
Roof Floor Rmt 59.27 1.00 59.27
Total Rmt 59.27 63.00
10.3 FLASHING TYPE 3 CODE-A12-08 & 7/A11-01
Basement Floor Rmt 0.00 1.00 0.00
Lower Ground Floor Rmt 0.00 1.00 0.00
Mezzanine Floor Rmt 0.00 1.00 0.00
Ground Floor Rmt 0.00 1.00 0.00
First Floor Rmt 0.00 1.00 0.00
Second Floor Rmt 0.00 1.00 0.00
Third Floor Rmt 0.00 1.00 0.00
Fourth Floor Rmt 0.00 1.00 0.00
Roof Floor Rmt 372.34 1.00 372.34
Total Rmt 372.34 391.00
10.4 FLASHING TYPE 4 CODE-A12-08 & 7A/A11-01
Basement Floor Rmt 0.00 1.00 0.00
Lower Ground Floor Rmt 0.00 1.00 0.00
Mezzanine Floor Rmt 0.00 1.00 0.00
Ground Floor Rmt 0.00 1.00 0.00
First Floor Rmt 84.65 1.00 84.65
Second Floor Rmt 0.00 1.00 0.00
Third Floor Rmt 0.00 1.00 0.00
Fourth Floor Rmt 0.00 1.00 0.00
Total Rmt 84.65 89.00
11 ROOF LEVEL FINISH
11.1 LOOSE GRAVEL STONE CODE-A12-09 & 15/A14-01
Basement Floor Sqm 0.00 1.00 0.00
Lower Ground Floor Sqm 0.00 1.00 0.00
Mezzanine Floor Sqm 0.00 1.00 0.00
Ground Floor Sqm 0.00 1.00 0.00
First Floor Sqm 0.00 1.00 0.00
Second Floor Sqm 0.00 1.00 0.00
Third Floor Sqm 0.00 1.00 0.00
Fourth Floor Sqm 0.00 1.00 0.00
Roof Floor Sqm 1729.55 1.00 1729.55
Total Sqm 1729.55 1817.00
11.2 GREEN ROOF CODE-A12-09 & 15/A14-01
Basement Floor Sqm 0.00 1.00 0.00
Lower Ground Floor Sqm 0.00 1.00 0.00
Mezzanine Floor Sqm 0.00 1.00 0.00
Ground Floor Sqm 0.00 1.00 0.00
First Floor Sqm 128.18 1.00 128.18
Second Floor Sqm 0.00 1.00 0.00
Third Floor Sqm 0.00 1.00 0.00
Fourth Floor Sqm 0.00 1.00 0.00
Total Sqm 128.18 135.00
11.3 WOODEN DECKING CODE-A12-09 & 15/A14-01
Basement Floor Sqm 0.00 1.00 0.00
Lower Ground Floor Sqm 0.00 1.00 0.00
Mezzanine Floor Sqm 0.00 1.00 0.00
Ground Floor Sqm 0.00 1.00 0.00
First Floor Sqm 99.10 1.00 99.10
Second Floor Sqm 0.00 1.00 0.00
Third Floor Sqm 0.00 1.00 0.00
Fourth Floor Sqm 0.00 1.00 0.00
Total Sqm 99.10 105.00
11.4 ZINC ROOFING CODE-A12-09 & 15/A14-01
Basement Floor Sqm 0.00 1.00 0.00
Lower Ground Floor Sqm 0.00 1.00 0.00
Mezzanine Floor Sqm 0.00 1.00 0.00
Ground Floor Sqm 0.00 1.00 0.00
First Floor Sqm 0.00 1.00 0.00
Second Floor Sqm 0.00 1.00 0.00
Third Floor Sqm 0.00 1.00 0.00
Fourth Floor Sqm 0.00 1.00 0.00
roof Floor Sqm 224.83 1.00 224.83
Total Sqm 224.83 237.00
11.5 KOTA STONE CODE-A12-09 & 4/A14-01
Basement Floor Sqm 0.00 1.00 0.00
Lower Ground Floor Sqm 0.00 1.00 0.00
Mezzanine Floor Sqm 0.00 1.00 0.00
Ground Floor Sqm 0.00 1.00 0.00
First Floor Sqm 2.55 1.00 2.55
Second Floor Sqm 0.00 1.00 0.00
Third Floor Sqm 0.00 1.00 0.00
Fourth Floor Sqm 0.00 1.00 0.00
Total Sqm 2.55 3.00
Basement Floor Sqm 1.00 0.00
Lower Ground Floor Sqm 1.00 0.00
Mezzanine Floor Sqm 1.00 0.00
Ground Floor Sqm 1.00 0.00
First Floor Sqm 1.00 0.00
Second Floor Sqm 1.00 0.00
Third Floor Sqm 1.00 0.00
Fourth Floor Sqm 1.00 0.00
Total Sqm 0.00 0.00
12 DRAINAGE WALL FINISH
12.1 STONE WALL-LAWN DRAIN CODE-A12-11 & 1/A11-02
Basement Floor Rmt 0.00 1.00 0.00
Lower Ground Floor Rmt 0.00 1.00 0.00
Mezzanine Floor Rmt 0.00 1.00 0.00
Ground Floor Rmt 41.04 1.00 41.04
First Floor Rmt 27.03 1.00 27.03
Second Floor Rmt 0.00 1.00 0.00
Third Floor Rmt 0.00 1.00 0.00
Fourth Floor Rmt 0.00 1.00 0.00
Total Rmt 68.06 72.00
12.2 STONE WALL-STONE FLOOR DRAIN CODE-A12-11 & 2/A11-02
Basement Floor Rmt 0.00 1.00 0.00
Lower Ground Floor Rmt 70.43 1.00 70.43
Mezzanine Floor Rmt 0.00 1.00 0.00
Ground Floor Rmt 59.66 1.00 59.66
First Floor Rmt 0.00 1.00 0.00
Second Floor Rmt 0.00 1.00 0.00
Third Floor Rmt 0.00 1.00 0.00
Fourth Floor Rmt 0.00 1.00 0.00
Total Rmt 130.09 137.00
12.3 ALUM. GLAZING - STONE FLOOR DRAIN CODE-A12-11 & 3/A11-02
Basement Floor Rmt 0.00 1.00 0.00
Lower Ground Floor Rmt 40.02 1.00 40.02
Mezzanine Floor Rmt 0.00 1.00 0.00
Ground Floor Rmt 3.60 1.00 3.60
First Floor Rmt 0.00 1.00 0.00
Second Floor Rmt 0.00 1.00 0.00
Third Floor Rmt 0.00 1.00 0.00
Fourth Floor Rmt 0.00 1.00 0.00
Total Rmt 43.62 46.00
12.4 STONE WALL - STONE FLOOR (WITHOUT PEBBLE) DRAIN CODE-A12-11 & 4/A11-02
Basement Floor Rmt 0.00 1.00 0.00
Lower Ground Floor Rmt 196.21 1.00 196.21
Mezzanine Floor Rmt 0.00 1.00 0.00
Ground Floor Rmt 0.00 1.00 0.00
First Floor Rmt 0.00 1.00 0.00
Second Floor Rmt 0.00 1.00 0.00
Third Floor Rmt 0.00 1.00 0.00
Fourth Floor Rmt 0.00 1.00 0.00
Total Rmt 196.21 207.00
12.5 STONE FLOOR - STONE FLOOR DRAIN CODE-A12-11 & 5/A11-02
Basement Floor Rmt 0.00 1.00 0.00
Lower Ground Floor Rmt 1.80 1.00 1.80
Mezzanine Floor Rmt 0.00 1.00 0.00
Ground Floor Rmt 0.00 1.00 0.00
First Floor Rmt 0.00 1.00 0.00
Second Floor Rmt 0.00 1.00 0.00
Third Floor Rmt 0.00 1.00 0.00
Fourth Floor Rmt 0.00 1.00 0.00
Total Rmt 1.80 2.00
12.6 STONE FLOOR - ROAD DRAIN (HEAVY DUTY) CODE-A12-11 & 6/A11-02
Basement Floor Rmt 0.00 1.00 0.00
Lower Ground Floor Rmt 0.00 1.00 0.00
Mezzanine Floor Rmt 0.00 1.00 0.00
Ground Floor Rmt 0.00 1.00 0.00
First Floor Rmt 0.00 1.00 0.00
Second Floor Rmt 0.00 1.00 0.00
Third Floor Rmt 0.00 1.00 0.00
Fourth Floor Rmt 0.00 1.00 0.00
Total Rmt 0.00 0.00
12.7 STONE WALL - ROAD DRAIN CODE-A12-11 & 7/A11-02
Basement Floor Rmt 0.00 1.00 0.00
Lower Ground Floor Rmt 0.00 1.00 0.00
Mezzanine Floor Rmt 0.00 1.00 0.00
Ground Floor Rmt 76.96 1.00 76.96
First Floor Rmt 0.00 1.00 0.00
Second Floor Rmt 0.00 1.00 0.00
Third Floor Rmt 0.00 1.00 0.00
Fourth Floor Rmt 0.00 1.00 0.00
Total Rmt 76.96 81.00
15.1 GUARD RAIL CODE-A12-12 & 03/A7-22
Basement Floor Rmt 0.00 1.00 0.00
Lower Ground Floor Rmt 38.98 1.00 38.98
Mezzanine Floor Rmt 0.00 1.00 0.00
Ground Floor Rmt 55.54 1.00 55.54
First Floor Rmt 127.69 1.00 127.69
Second Floor Rmt 0.00 1.00 0.00
Third Floor Rmt 0.00 1.00 0.00
Fourth Floor Rmt 0.00 1.00 0.00
Total Rmt 222.21 234.00
15.2 DOUBLE HANDLE WOODEN RAIL CODE-A12-12 & 06/A7-22
Basement Floor Rmt 1.00 0.00
Lower Ground Floor Rmt 1.00 0.00
Mezzanine Floor Rmt 1.00 0.00
Ground Floor Rmt 1.00 0.00
First Floor Rmt 1.00 0.00
Second Floor Rmt 1.00 0.00
Third Floor Rmt 1.00 0.00
Fourth Floor Rmt 1.00 0.00
Total Rmt 0.00 0.00
15.3 WALL MOUNTED S.S RAIL CODE-A12-12 & 01/A7-22
Basement Floor Rmt 0.00 1.00 0.00
Lower Ground Floor Rmt 29.29 1.00 29.29
Mezzanine Floor Rmt 0.00 1.00 0.00
Ground Floor Rmt 29.29 1.00 29.29
First Floor Rmt 13.03 1.00 13.03
Second Floor Rmt 0.00 1.00 0.00
Third Floor Rmt 0.00 1.00 0.00
Fourth Floor Rmt 0.00 1.00 0.00
Total Rmt 71.61 76.00
15.4 WALL MOUNTED WOODEN RAIL CODE-A12-12 & 02/A7-22
Basement Floor Rmt 1.00 0.00
Lower Ground Floor Rmt 1.00 0.00
Mezzanine Floor Rmt 1.00 0.00
Ground Floor Rmt 1.00 0.00
First Floor Rmt 1.00 0.00
Second Floor Rmt 1.00 0.00
Third Floor Rmt 1.00 0.00
Fourth Floor Rmt 1.00 0.00
Total Rmt 0.00 0.00
15.5 GLASS WITH WOODEN RAIL CODE-A12-12 & 09/A7-22
Basement Floor Rmt 0.00 1.00 0.00
Lower Ground Floor Rmt 0.00 1.00 0.00
Mezzanine Floor Rmt 0.00 1.00 0.00
Ground Floor Rmt 40.94 1.00 40.94
First Floor Rmt 13.50 1.00 13.50
Second Floor Rmt 0.00 1.00 0.00
Third Floor Rmt 0.00 1.00 0.00
Fourth Floor Rmt 0.00 1.00 0.00
Total Rmt 54.44 58.00
15.6 GLASS WITH WOODEN TOP RAIL CODE-A12-12 & 09/A7-22
Basement Floor Rmt 0.00 1.00 0.00
Lower Ground Floor Rmt 0.00 1.00 0.00
Mezzanine Floor Rmt 0.00 1.00 0.00
Ground Floor Rmt 67.25 1.00 67.25
First Floor Rmt 20.70 1.00 20.70
Second Floor Rmt 0.00 1.00 0.00
Third Floor Rmt 0.00 1.00 0.00
Fourth Floor Rmt 0.00 1.00 0.00
Total Rmt 87.95 93.00
15.7 G.I RAILING CODE-A12-12 & 07/A7-22
Basement Floor Rmt 1.00 0.00
Lower Ground Floor Rmt 1.00 0.00
Mezzanine Floor Rmt 1.00 0.00
Ground Floor Rmt 1.00 0.00
First Floor Rmt 1.00 0.00
Second Floor Rmt 1.00 0.00
Third Floor Rmt 1.00 0.00
Fourth Floor Rmt 1.00 0.00
Total Rmt 0.00 0.00
15.8 WOODEN RAIL CODE-A12-12 & 10/A7-22
Basement Floor Rmt 1.00 0.00
Lower Ground Floor Rmt 1.00 0.00
Mezzanine Floor Rmt 1.00 0.00
Ground Floor Rmt 1.00 0.00
First Floor Rmt 1.00 0.00
Second Floor Rmt 1.00 0.00
Third Floor Rmt 1.00 0.00
Fourth Floor Rmt 1.00 0.00
Total Rmt 0.00 0.00
15.9 GLASS WITH SS CAP CODE-A12-12 & 08/A7-22
Basement Floor Rmt 1.00 0.00
Lower Ground Floor Rmt 1.00 0.00
Mezzanine Floor Rmt 1.00 0.00
Ground Floor Rmt 1.00 0.00
First Floor Rmt 1.00 0.00
Second Floor Rmt 1.00 0.00
Third Floor Rmt 1.00 0.00
Fourth Floor Rmt 1.00 0.00
Total Rmt 0.00 0.00
14 COPING FINISH
14.1 COPING 1 CODE-A12-08 & 4/A11-01
Basement Floor Sqm 0.00 1.00 0.00
Lower Ground Floor Sqm 0.00 1.00 0.00
Mezzanine Floor Sqm 0.00 1.00 0.00
Ground Floor Sqm 0.00 1.00 0.00
First Floor Sqm 0.00 1.00 0.00
Second Floor Sqm 0.00 1.00 0.00
Third Floor Sqm 0.00 1.00 0.00
Fourth Floor Sqm 30.35 1.00 30.35
Total Sqm 30.35 32.00
14.2 COPING 2 CODE-A12-08 & 1/A11-01
Basement Floor Sqm 0.00 1.00 0.00
Lower Ground Floor Sqm 42.16 1.00 42.16
Mezzanine Floor Sqm 0.00 1.00 0.00
Ground Floor Sqm 0.00 1.00 0.00
First Floor Sqm 19.67 1.00 19.67
Second Floor Sqm 0.00 1.00 0.00
Third Floor Sqm 0.00 1.00 0.00
Fourth Floor Sqm 0.00 1.00 0.00
Roof Floor Sqm 181.60 1.00 181.60
Total Sqm 243.43 256.00
14.3 COPING 3 CODE-A12-08 & 2/A11-01
Basement Floor Sqm 0.00 1.00 0.00
Lower Ground Floor Sqm 0.00 1.00 0.00
Mezzanine Floor Sqm 0.00 1.00 0.00
Ground Floor Sqm 0.00 1.00 0.00
First Floor Sqm 0.00 1.00 0.00
Second Floor Sqm 0.00 1.00 0.00
Third Floor Sqm 0.00 1.00 0.00
Fourth Floor Sqm 0.00 1.00 0.00
Roof Floor Sqm 59.34 1.00 59.34
Total Sqm 59.34 63.00
14.4 COPING 4 CODE-A12-08 & 3/A11-01
Basement Floor Sqm 0.00 1.00 0.00
Lower Ground Floor Sqm 0.00 1.00 0.00
Mezzanine Floor Sqm 0.00 1.00 0.00
Ground Floor Sqm 0.00 1.00 0.00
First Floor Sqm 0.00 1.00 0.00
Second Floor Sqm 0.00 1.00 0.00
Third Floor Sqm 0.00 1.00 0.00
Fourth Floor Sqm 0.00 1.00 0.00
Roof Floor Sqm 59.10 1.00 59.10
Total Sqm 59.10 63.00
14.5 COPING 5 CODE-A12-08 & 6/A11-01
Basement Floor Sqm 1.00 0.00
Lower Ground Floor Sqm 1.00 0.00
Mezzanine Floor Sqm 1.00 0.00
Ground Floor Sqm 1.00 0.00
First Floor Sqm 1.00 0.00
Second Floor Sqm 1.00 0.00
Third Floor Sqm 1.00 0.00
Fourth Floor Sqm 1.00 0.00
Total Sqm 0.00 0.00
GRANITE COUNTER Cum 20.00 0.075 1.50
25MM THICK STEEL GREY GRANITE FLOORING Cum 166.00 0.075 12.45
25 MM THICK GRAY GRANITE FLOORING Cum 169.00 0.075 12.68
MANDANA-1 (25MM THICK GRANITE) FLOORING Cum 1742.00 0.075 130.65
MANDANA-1 (25MM THICK GRANITE) STAIRCASE FLOORING Cum 33.00 0.075 2.48
MANDANA-2 (25MM THICK GRANITE) FLOORING Cum 122.00 0.075 9.15
25MM THICK SANDSTONE Cum 67.00 0.075 5.03
25MM THICK KOTA STONE FLOORING Cum 662.00 0.075 49.65
25MM THICK KOTA STONE FLOORING (stair) Cum 290.00 0.075 21.75
10 MM THICK VITRIFIED TILES FLOORING Cum 0.00 0.075 0.00
S.S WALK OF MATT Cum 24.00 0.081 1.94
G.I WALK OF MATT Cum 0.00 0.081 0.00
VDF CONCERETE FLOORING Cum 155.00 0.000 155.00
WOODEN DECK Cum 102.00 0.125 12.75
RUBBER TILE FLOORING Cum 0.00 0.075 0.00
Total Cum 415.02 436.00
SELF LEVELLING MORTAR
GI WALK OFF GRATING Sqm 0.00 1.000 0.00
SS WALK OFF GRATING Sqm 22.73 1.000 22.73
CARPET TILE FLOORING Sqm 0.00 1.000 0.00
WOODEN DECK FLOORIGN Sqm 96.55 1.000 96.55
RUBBER TILE FLOORING Sqm 0.00 1.000 0.00
Total Sqm 119.28 126.00
EXPANSION JOINT-EXTERIOR CODE-A12-13 & A11-03
1 ROOF TYPE - 1 (1-A11-03)
Basement Floor Rmt 0.00 1.00 0.00
Lower Ground Floor Rmt 0.00 1.00 0.00
Mezzanine Floor Rmt 0.00 1.00 0.00
Ground Floor Rmt 0.00 1.00 0.00
First Floor Rmt 0.00 1.00 0.00
Second Floor Rmt 0.00 1.00 0.00
Third Floor Rmt 0.00 1.00 0.00
Fourth Floor Rmt 5.78 1.00 5.78
Total Rmt 5.78 7.00
2 ROOF TYPE - 2 (2-A11-03)
Basement Floor Rmt 0.00 1.00 0.00
Lower Ground Floor Rmt 0.00 1.00 0.00
Mezzanine Floor Rmt 0.00 1.00 0.00
Ground Floor Rmt 0.00 1.00 0.00
First Floor Rmt 3.70 1.00 3.70
Second Floor Rmt 0.00 1.00 0.00
Third Floor Rmt 0.00 1.00 0.00
Fourth Floor Rmt 12.12 1.00 12.12
Total Rmt 15.82 17.00
3 ROOF TYPE - 3 (A11-03)
Basement Floor Rmt 0.00 1.00 0.00
Lower Ground Floor Rmt 0.00 1.00 0.00
Mezzanine Floor Rmt 0.00 1.00 0.00
Ground Floor Rmt 34.10 1.00 34.10
First Floor Rmt 0.00 1.00 0.00
Second Floor Rmt 0.00 1.00 0.00
Third Floor Rmt 0.00 1.00 0.00
Fourth Floor Rmt 0.72 1.00 0.72
Total Rmt 34.82 37.00
4 WALL TYPE - 1 (4-A11-03)
Basement Floor Rmt 0.00 1.00 0.00
Lower Ground Floor Rmt 0.00 1.00 0.00
Mezzanine Floor Rmt 0.00 1.00 0.00
Ground Floor Rmt 21.60 1.00 21.60
First Floor Rmt 7.20 1.00 7.20
Second Floor Rmt 0.00 1.00 0.00
Third Floor Rmt 0.00 1.00 0.00
Fourth Floor Rmt 0.00 1.00 0.00
Total Rmt 28.80 31.00
Basement Floor Rmt 0.00 1.00 0.00
Lower Ground Floor Rmt 7.20 1.00 7.20
Mezzanine Floor Rmt 0.00 1.00 0.00
Ground Floor Rmt 7.20 1.00 7.20
First Floor Rmt 7.20 1.00 7.20
Second Floor Rmt 0.00 1.00 0.00
Third Floor Rmt 0.00 1.00 0.00
Fourth Floor Rmt 0.00 1.00 0.00
Total Rmt 21.60 23.00
9.2 EXPANSION JOINT-INTERIOR CODE-A12-13 & A11-03
1 WALL TYPE-3 (5-A14-11)
Basement Floor Rmt 0.00 1.00 0.00
Lower Ground Floor Rmt 86.40 1.00 86.40
Mezzanine Floor Rmt 0.00 1.00 0.00
Ground Floor Rmt 28.80 1.00 28.80
First Floor Rmt 43.20 1.00 43.20
Second Floor Rmt 0.00 1.00 0.00
Third Floor Rmt 0.00 1.00 0.00
Fourth Floor Rmt 0.00 1.00 0.00
Total Rmt 158.40 167.00
2 FLOORING TYPE-1 (1-A14-11)
Basement Floor Rmt 0.00 1.00 0.00
Lower Ground Floor Rmt 0.00 1.00 0.00
Mezzanine Floor Rmt 0.00 1.00 0.00
Ground Floor Rmt 5.35 1.00 5.35
First Floor Rmt 3.55 1.00 3.55
Second Floor Rmt 0.00 1.00 0.00
Third Floor Rmt 0.00 1.00 0.00
Fourth Floor Rmt 0.00 1.00 0.00
Total Rmt 8.90 10.00
3 FLOORING TYPE-2 (2-A14-11)
Basement Floor Rmt 0.00 1.00 0.00
Lower Ground Floor Rmt 0.00 1.00 0.00
Mezzanine Floor Rmt 0.00 1.00 0.00
Ground Floor Rmt 11.75 1.00 11.75
First Floor Rmt 0.00 1.00 0.00
Second Floor Rmt 0.00 1.00 0.00
Third Floor Rmt 0.00 1.00 0.00
Fourth Floor Rmt 0.00 1.00 0.00
Total Rmt 11.75 13.00
4 FLOORING TYPE-3 (3-A14-11)
Basement Floor Rmt 0.00 1.00 0.00
Lower Ground Floor Rmt 0.00 1.00 0.00
Mezzanine Floor Rmt 0.00 1.00 0.00
Ground Floor Rmt 3.31 1.00 3.31
First Floor Rmt 9.34 1.00 9.34
Second Floor Rmt 0.00 1.00 0.00
Third Floor Rmt 0.00 1.00 0.00
Fourth Floor Rmt 0.00 1.00 0.00
Total Rmt 12.65 14.00
5 FLOORING TYPE-4 (4-A14-11)
Basement Floor Rmt 0.00 1.00 0.00
Lower Ground Floor Rmt 0.00 1.00 0.00
Mezzanine Floor Rmt 0.00 1.00 0.00
Ground Floor Rmt 7.49 1.00 7.49
First Floor Rmt 2.97 1.00 2.97
Second Floor Rmt 0.00 1.00 0.00
Third Floor Rmt 0.00 1.00 0.00
Fourth Floor Rmt 0.00 1.00 0.00
Total Rmt 10.45 11.00
13 WATERPROOFING BELOW GROUND LEVEL
13.1 1.2 mm HDPE MEMBRANE PRESSURE SENSITIVE ADHESIVE (Below Footing)
Basement level 1.0 2730.01 1.00 2730.01
13.2 1.2MM CROSS LAMINATED SBS MODIFIED MEMBRANE + 8MM THK HDPE PROTECTION BOARD
Basement level 1.0 1029.71 1.00 1029.71
13.3 1.2 mm HDPE MEMBRANE PRESSURE SENSITIVE ADHESIVE (below grade slab)
Basement level 1.0 4818.89 1.00 4818.89
13.3 1.2MM CROSS LAMINATED SBS MODIFIED MEMBRANE + 8MM THK HDPE PROTECTION BOARD ON WALL
Basement level 1.0 398.87 1.00 398.87
SuPr ENGINEERING CONSULTANTS 307, SIDDHARTH UPSCALE, VASNA ROAD VADODARA-390007 TEL- 0265-3149701 MEASUREMENT
PROJECT : GUJARAT VANDANA MUSEUM, GUJARAT
VADODARA ARCHITECT : OPOLIS
DATE : 05-09-25 CLIENT : DIRECTORATE OF ARCHEOLOGY AND MUSEUMS, G.O.G
PREPARED BY : MANDIPSINH CHECKED BY :
SR.NO. PARTICULARS NO. L B D QTY.
2.1 100MM THICK AAC BLOCK MASONRY CODE-A13-01 & 1/A13-08
LOWER GROUND FLOOR PLAN
Drg Title : GVM_A4_DETAILED PLAN
Drg Date : 11-09-2025
GROUND FLOOR PLAN
Drg Title : GVM_A4_DETAILED PLAN
Drg Date : 11-09-2025
Drg Title : GVM_A4_DETAILED PLAN
Drg Date : 11-09-2025
2.3 150MM THICK FLY ASH BLOCK MASONRY CODE-A13-01 & 1/A13-08
LOWER GROUND FLOOR PLAN
Drg Title : GVM_A4_DETAILED PLAN
Drg Date : 11-09-2025
GROUND FLOOR PLAN
Drg Title : GVM_A4_DETAILED PLAN
Drg Date : 11-09-2025
2.5 250MM THICK FLY ASH BLOCK MASONRY CODE-A13-01 & 1/A13-08
LOWER GROUND FLOOR PLAN
Drg Title : GVM_A4_DETAILED PLAN
Drg Date : 11-09-2025
Utsah gallery 1.0 1.48 0.25 6.45 2.38
fire exit lobby 1.0 2.59 0.25 6.45 4.18
GROUND FLOOR PLAN
Drg Title : GVM_A4_DETAILED PLAN
Drg Date : 11-09-2025
utsah gallary lobby 2.0 7.75 0.25 5.90 22.86
exit passage 1.0 5.30 0.25 5.90 7.82
utsah galery FOH & BOH 1.0 6.32 0.25 5.90 9.33
plumbing shaft 1.0 1.59 0.25 5.90 2.35
Drg Title : GVM_A4_DETAILED PLAN
Drg Date : 11-09-2025
lobby + souvenir 1.0 5.30 0.25 6.10 8.08
electrical shaft 1.0 2.17 0.25 6.10 3.32
utkarsh gallery BOH & FOH 1.0 6.32 0.25 6.10 9.64
2.6 300MM THICK FLY ASH BLOCK MASONRY CODE-A13-01 & 1/A13-08
LOWER GROUND FLOOR PLAN
Drg Title : GVM_A4_DETAILED PLAN
Drg Date : 11-09-2025
GROUND FLOOR PLAN
Drg Title : GVM_A4_DETAILED PLAN
Drg Date : 11-09-2025
Drg Title : GVM_A4_DETAILED PLAN
Drg Date : 11-09-2025
2.7 350MM THICK AAC BLOCK MASONRY CODE-A13-01 & 1/A13-08
GROUND FLOOR PLAN
Drg Title : GVM_A4_DETAILED PLAN
Drg Date : 11-09-2025
4.2 200 MM THICK AAC BLOCK MASONRY CODE-01A13-08
LOWER GROUND FLOOR PLAN
Drg Title : GVM_A4_DETAILED PLAN
Drg Date : 11-09-2025
Drg Title : GVM_A4_DETAILED PLAN
Drg Date : 11-09-2025
4.3 250 MM THICK AAC BLOCK MASONRY CODE-01A13-08
LOWER GROUND FLOOR PLAN
Drg Title : GVM_A4_DETAILED PLAN
Drg Date : 11-09-2025
GROUND FLOOR PLAN
Drg Title : GVM_A4_DETAILED PLAN
Drg Date : 11-09-2025
Drg Title : GVM_A4_DETAILED PLAN
Drg Date : 11-09-2025
> INTERNAL PLASTER
LOWER GROUND FLOOR Floor ht = 7.30
Drg Title : FINISHES DIAGRAM-INT WALLS Slab= 0.20
Drg No : A12-05 7.10
Drg Date : 25-09-2025
Plaster EXHIBITION EQUIPTMENT (A9-06 sec 08 n) 2.0 16.10 7.10 228.62
add jambs & soffits 1.0 8.70 0.15 1.31
add jambs & soffits 1.0 8.70 0.15 1.31
plaster EXHIBITION PREP CLEAN RM (A9-04 sec 18 n) 2.0 6.30 7.10 89.39
add jambs & soffits 1.0 8.70 0.15 1.31
plaster PAINT & SPRAY (A9-07 sec 09) 1.0 28.75 P-L 7.10 204.13
add jambs & soffits 1.0 8.70 0.15 1.31
add jambs & soffits 1.0 6.30 0.15 0.95
plaster Pump rm (A9-20 sec 29) 1.0 14.24 avg 9.85 140.16
add jambs & soffits 1.0 5.70 0.15 0.86
plaster Utsahh gallery (A9-20 sec 29) 1.0 113.54 8.87 1006.84
add jambs & soffits 1.0 10.20 0.15 1.53
add jambs & soffits 1.0 10.20 0.15 1.53
add jambs & soffits 1.0 6.30 0.15 0.95
add jambs & soffits 1.0 8.70 0.15 1.31
on columns 3.0 2.36 8.87 62.68
Plaster Passage outside toilet (A9-19 sec 27) 1.0 18.13 4.00 72.51
GROUND FLOOR Floor ht = 6.65
Drg Title : FINISHES DIAGRAM-INT WALLS Slab= 0.20
Drg No : A12-05 6.45
Drg Date : 25-09-2025
plaster TEMPORARY GALLERY (A9-15 sec 21) 1.0 11.24 5.70 64.09
add jambs & soffits 1.0 10.20 0.15 1.53
add jambs & soffits 1.0 8.70 0.15 1.31
plaster TEMPORARY EXHIBIT (A9-15 sec 21) 1.0 12.94 4.50 58.24
plaster TEMPORARY EXHIBIT 1.0 15.91 6.60 104.97
add jambs & soffits 1.0 10.80 0.15 1.62
Plaster Pre function Court (A9-16) 1.0 4.30 7.20 30.96
add jambs & soffits 1.0 12.30 0.15 1.85
add jambs & soffits 1.0 12.30 0.15 1.85
add jambs & soffits 1.0 6.60 0.15 0.99
Plaster Service passage (A9-18 sec 26) 1.0 58.80 7.00 411.59
add jambs & soffits 1.0 8.70 0.15 1.31
add jambs & soffits 1.0 8.70 0.15 1.31
less lift opn -0.5 1.20 2.10 -1.26
add jambs & soffits 1.0 9.00 0.15 1.35
Plaster Souvenir shop (A9-14 sec 19) 1.0 46.54 4.75 221.07
Plaster Utsah gallery (A9-19 sec 28) 1.0 97.71 P-line 7.00 684.00
add jambs & soffits 1.0 10.20 0.15 1.53
add jambs & soffits 1.0 10.20 0.15 1.53
add jambs & soffits 1.0 8.70 0.15 1.31
Plaster Toilet passage (A9-19 sec 27) 1.0 14.61 6.25 91.28
add jambs & soffits 1.0 14.30 0.15 2.15
Plaster Toilet passage (A9-19 sec 27) 1.0 12.09 3.40 41.11
Plaster Pre function lobby (A9-15) 1.0 67.53 P-line 6.90 465.94
add jambs & soffits 1.0 6.60 0.15 0.99
less lift opn -0.5 1.20 2.40 -1.44
add jambs & soffits 1.0 11.95 0.15 1.79
add jambs & soffits 1.0 5.70 0.15 0.86
add jambs & soffits 1.0 10.20 0.15 1.53
add jambs & soffits 1.0 10.20 0.15 1.53
add jambs & soffits 1.0 10.20 0.15 1.53
add jambs & soffits 1.0 10.20 0.15 1.53
add jambs & soffits 1.0 9.90 0.15 1.49
add jambs & soffits 1.0 12.30 0.15 1.85
South Passage (A9-19 sec 28) 1.0 152.78 7.00 1069.46
LESS LIFT OPN -1.0 1.20 2.10 -2.52
Add Jambs & soffits 15.0 14.33 0.15 32.23
1ST FLOOR Floor ht = 7.10
Drg Title : FINISHES DIAGRAM-INT WALLS Slab= 0.20
Drg No : A12-05 6.90
Drg Date : 25-09-2025
add jambs & soffits 1.0 5.70 0.15 0.86
add jambs & soffits 1.0 6.30 0.15 0.95
add jambs & soffits 1.0 10.80 0.15 1.62
add jambs & soffits 1.0 12.00 0.15 1.80
add jambs & soffits 1.0 12.00 0.15 1.80
add jambs & soffits 1.0 10.80 0.15 1.62
add jambs & soffits 1.0 10.20 0.15 1.53
add jambs & soffits 1.0 6.30 0.15 0.95
Service passage (A9-16 sec 23) 1.0 61.97 6.00 371.82
add jambs & soffits 1.0 5.70 0.15 0.86
add jambs & soffits 1.0 8.70 0.15 1.31
add jambs & soffits 1.0 5.70 0.15 0.86
add jambs & soffits 1.0 6.60 0.15 0.99
plaster VIP LOBBY 1.0 73.58 6.00 441.48
LESS LIFT OPN -0.5 1.20 2.10 -1.26
PL DOUBLE HT PRE-F LOBBY (A9-15) 2.0 3.23 10.55 68.05
S.passage to ahu lobby (A9-14 sec 20) 1.0 22.98 4.76 109.25
add jambs & soffits 1.0 5.70 0.15 0.86
add jambs & soffits 1.0 5.70 0.15 0.86
PL BOUNTIFUL GUJARAT (A9-19 sec 27) 1.0 111.69 7.00 781.82
add jambs & soffits 1.0 10.20 0.15 1.53
add jambs & soffits 1.0 6.30 0.15 0.95
add jambs & soffits 1.0 10.20 0.15 1.53
add jambs & soffits 1.0 8.70 0.15 1.31
PL SOUTH PASSAGE 1.0 139.58 6.00 837.50
add jambs & soffits 1.0 8.32 0.15 1.25
add jambs & soffits 1.0 8.32 0.15 1.25
add jambs & soffits 1.0 8.32 0.15 1.25
add jambs & soffits 1.0 8.32 0.15 1.25
add jambs & soffits 1.0 8.32 0.15 1.25
add jambs & soffits 1.0 8.32 0.15 1.25
add jambs & soffits 1.0 8.32 0.15 1.25
add jambs & soffits 1.0 8.32 0.15 1.25
add jambs & soffits 1.0 8.32 0.15 1.25
add jambs & soffits 1.0 8.32 0.15 1.25
add jambs & soffits 1.0 8.32 0.15 1.25
add jambs & soffits 1.0 8.32 0.15 1.25
add jambs & soffits 1.0 8.32 0.15 1.25
add jambs & soffits 1.0 8.32 0.15 1.25
add jambs & soffits 1.0 10.20 0.15 1.53
add jambs & soffits 1.0 11.95 0.15 1.79
PL Double ht exit passage (A9-20) 1.0 45.98 6.00 275.88
add jambs & soffits 1.0 11.10 0.15 1.67
PL BOUNTIFUL GUJARAT (A9-07) 1.0 49.26 5.70 280.79
add jambs & soffits 1.0 32.17 0.15 4.83
add jambs & soffits 1.0 32.17 0.15 4.83
add jambs & soffits 1.0 9.00 0.15 1.35
PL BOUNTIFUL GUJARAT (A9-07) 1.0 22.50 5.70 128.25
add jambs & soffits 1.0 10.20 0.15 1.53
add jambs & soffits 1.0 11.10 0.15 1.67
>> INTERNAL PUTTY
LOWER GROUND FLOOR Floor ht = 7.30
Drg Title : FINISHES DIAGRAM-INT WALLS Slab= 0.20
Drg No : A12-05 7.10
Drg Date : 25-09-2025
EXHIBITION EQUIPTMENT (A9-06 sec 08)
putty On columns 2.0 3.00 7.10 42.60
add jambs & soffits 1.0 6.30 0.15 0.95
putty Boh passage (A9-16 sec 23) 1.0 28.93 3.40 98.36
add jambs & soffits 1.0 5.70 0.15 0.86
add jambs & soffits 1.0 6.30 0.15 0.95
add jambs & soffits 1.0 5.70 0.15 0.86
add jambs & soffits 1.0 6.30 0.15 0.95
South passage 1.0 150.50 7.10 1068.57
add jambs & soffits 1.0 6.30 0.15 0.95
add jambs & soffits 1.0 6.30 0.15 0.95
add jambs & soffits 1.0 9.14 0.15 1.37
add jambs & soffits 1.0 9.79 0.15 1.47
add jambs & soffits 1.0 10.43 0.15 1.56
add jambs & soffits 1.0 11.08 0.15 1.66
add jambs & soffits 1.0 11.75 0.15 1.76
add jambs & soffits 1.0 12.37 0.15 1.86
add jambs & soffits 1.0 13.02 0.15 1.95
add jambs & soffits 1.0 13.67 0.15 2.05
add jambs & soffits 1.0 11.16 0.15 1.67
add jambs & soffits 1.0 5.93 0.15 0.89
add jambs & soffits 1.0 5.93 0.15 0.89
add jambs & soffits 1.0 14.33 0.15 2.15
add jambs & soffits 1.0 14.10 0.15 2.12
add jambs & soffits 1.0 6.30 0.15 0.95
add jambs & soffits 1.0 10.20 0.15 1.53
add jambs & soffits 1.0 10.20 0.15 1.53
Putty intro to siddhi gallery (A9-20 sec 30) 1.0 47.08 6.29 296.14
Putty intro to siddhi gallery (A9-20 sec 30) 1.0 42.90 6.29 269.86
add jambs & soffits 1.0 51.99 0.15 7.80
Passage near ST-G3 (A9-20 sec 30) 1.0 30.48 5.60 170.70
add jambs & soffits 1.0 6.60 0.15 0.99
Putty Service Passage 1.0 68.25 5.60 382.20
Ded Of Lift Opn -1.0 1.10 2.20 -2.42
GROUND FLOOR Floor ht = 6.65
Drg Title : FINISHES DIAGRAM-INT WALLS Slab= 0.20
Drg No : A12-05 6.45
Drg Date : 25-09-2025
Putty TEMPORARY GALLERY (A9-15 sec 21) 1.0 44.28 6.45 285.57
add jambs & soffits 1.0 6.30 0.15 0.95
Putty Pre function Court (A9-16) 1.0 6.68 7.20 48.06
Putty Pre function Court (A9-15) 1.0 3.60 0.70 2.52
Putty Pre function Court (A9-16) 1.0 8.35 7.20 60.13
add jambs & soffits 1.0 10.20 0.15 1.53
Putty ST-F1 1.0 25.38 P-line 7.00 177.66
Putty ST-G3 1.0 22.74 P-line 7.00 159.19
putty EXIT PASSAGE
Double ht Passage (up to GF top) 1.0 16.48 P-L 4.10 67.56
putty Exit passage Ramp (up tp GF top) 1.0 11.85 avg 4.35 51.55
Add Jambs & soffits 2.0 16.20 0.15 4.86
putty Exit passage ramp 1.0 33.88 5.11 173.13
Exit passage ramp 1.0 26.57 5.11 135.79
Lobby at ahu exit 1.0 4.06 5.70 23.14
putty Entrance lobby to pre function lobby (A9-15 sec 22) (A06-11 1) (HT up to FF) 1.0 2.25 6.00 13.50
Pre function lobby (temporary wall plaster) 1.0 4.28 4.20 17.95
Pre function lobby 1.0 5.40 7.20 38.88
Pre function lobby 1.0 4.68 5.10 23.84
1ST FLOOR Floor ht = 7.10
Drg Title : FINISHES DIAGRAM-INT WALLS Slab= 0.20
Drg No : A12-05 6.90
Drg Date : 25-09-2025
CEILING PLASTER
LOWER GROUND FLOOR
Drg Title : FINISHES DIAGRAM-INT WALLS
Drg No : A12-05
Drg Date : 25-09-2025
As per str dwg area (E X5 & AF Y2) 1.0 155.11 P-area 155.11
As per section A9-20
Drg Title : FINISHES DIAGRAM-INT WALLS
Drg No : A12-05
Drg Date : 25-09-2025
As per str dwg area (E X5 & AF Y2) 1.0 84.63 P-area 84.63
Exit passage 1.0 155.11 155.11
Lower Ground Floor
Drg Title : FINISHES DIAGRAM-INT WALLS
Drg No : A12-05
Drg Date : 25-09-2025
Janitor room 1.0 5.21 7.00 36.48
Drg Title : FINISHES DIAGRAM-INT WALLS
Drg No : A12-05
Drg Date : 25-09-2025
F-toilet 1.0 24.50 P-line 7.00 171.47
M-toilet 1.0 25.89 P-line 7.00 181.20
M-Toilet 1.0 16.40 P-line 6.35 104.14
Drg Title : FINISHES DIAGRAM-INT WALLS
Drg No : A12-05
Drg Date : 25-09-2025
M-Toilet 1.0 19.35 P-line 6.00 116.10
EXTERNAL PLASTER
Lower Ground Floor
Drg Title : FINISHES DIAGRAM-INT WALLS
Drg No : A12-05
Drg Date : 25-09-2025
Introduction to siddhi gallery (sec 22 /A9-22) 1.0 41.87 7.60 318.23
Grid G Q3 TO G Q8 ( HT FROM ELEVTION ) 1.0 66.30 AVG HT 5.19 343.97
Grid GQ8 TO GRID EF Y1 ( HT FROM ELEVTION ) 1.0 26.92 3.20 86.14
Ded of fire door -1.0 2.00 1.50 -3.00
Grid EF Y1 TO GRID AF Y1 ( HT FROM ELEVTION ) 1.0 27.38 AVG HT 2.23 61.03
Drg Title : FINISHES DIAGRAM-INT WALLS
Drg No : A12-05
Drg Date : 25-09-2025
Introduction to siddhi gallery (sec 22 /A9-22) 1.0 62.50 1.32 82.75
Grid G Q4 TO G Q8 ( HT FROM ELEVTION ) 1.0 86.78 7.20 624.80
Grid GQ8 TO GRID EF Y1 ( HT FROM ELEVTION ) 1.0 58.63 7.20 422.12
Pre function lobby 1.0 13.78 7.20 99.18
Grid F X4 TO GRID E X5 ( HT FROM ELEVTION ) 1.0 23.15 7.20 166.68
Grid AF Y1 TO GRID A Y2 ( HT FROM ELEVTION ) 1.0 17.87 7.20 128.69
Connecting bridge G plaster (A06-21) (ht=elevation dwg) 1.0 5.65 avg 10.51 59.32
Exit passage bridge (A9-19/sec 28) 1.0 56.73 7.80 442.51
Drg Title : FINISHES DIAGRAM-INT WALLS
Drg No : A12-05
Drg Date : 25-09-2025
Grid GQ8 TO GRID EF Y1 ( HT FROM ELEVTION ) 1.0 31.53 7.20 227.01
PRE FUNCTION COURT (A9-15) 1.0 18.00 7.20 129.60
side of columns 9.0 0.63 7.70 43.31
Ahu outer wall (Grid F X3 To A Y2) 1.0 32.97 8.10 267.08
Drg Title : FINISHES DIAGRAM-INT WALLS
Drg No : A12-05
Drg Date : 25-09-2025
Staircase 2.0 8.28 3.00 49.65
Parapet wall 1.0 240.19 2.30 552.44
13 WATERPROOFING WORK
13.1 LOCATION : TOILET
LOWER GROUND FLOOR
(Location : MALE & FEMALE TOILET)
Drg Title : 2025-09-18_GVM_A0-12_SUNK DIAGRAM
Drg Date : 19-09-2025
Female Toilet 1.0 25.05 P-area 25.05
Male Toilet 1.0 28.23 P-area 28.23
Female Toilet 1.0 24.90 P-line 1.00 24.90
Male Toilet 1.0 27.55 P-line 1.00 27.55
(Location :MALE & FEMALE TOILET)
Drg Title : 2025-09-18_GVM_A0-12_SUNK DIAGRAM
Drg Date : 19-09-2025
Male Toilet 1.0 22.19 P-area 22.19
Female Toilet 1.0 20.13 P-area 20.13
Male Toilet 1.0 13.89 P-area 13.89
Female Toilet 1.0 5.45 P-area 5.45
Male Toilet 1.0 25.89 P-line 1.00 25.89
Female Toilet 1.0 24.50 P-line 1.00 24.50
Male Toilet 1.0 19.35 P-line 1.00 19.35
Female Toilet 1.0 11.30 P-line 1.00 11.30
(Location : MALE & FEMALE TOILET)
Drg Title : 2025-09-18_GVM_A0-12_SUNK DIAGRAM
Drg Date : 19-09-2025
VIP Male Toilet 1.0 13.65 P-area 13.65
Female Toilet 1.0 11.53 P-area 11.53
Male Toilet 1.0 18.85 P-line 1.00 18.85
Janitor Store 1.0 5.60 1.00 5.60
Female Toilet 1.0 11.53 P-line 1.00 11.53
13.5 LOCATION : LIFT PIT WATERPROOFING (INSIDE)
LOWER GROUND FLOOR
(Location : SOUTH LIFT)
Drg Title : 2025-09-18_GVM_A0-12_SUNK DIAGRAM
Drg Date : 19-09-2025
13.5 LOCATION : LIFT PIT WATERPROOFING (OUTSIDE ON WALL)
LOWER GROUND FLOOR
(Location : ELIPTICAL LIFT)
Drg Title : 2025-09-18_GVM_A0-12_SUNK DIAGRAM
Drg Date : 19-09-2025
TEARRCE WATERPROOFING
2nd Floor Level Plan (above 2nd floor)
(Location : TERRACE)
Drg Title : GVM_A4_DETAILED PLAN
Drg Date : 11-09-2025
On Floor 1.0 2076.64 P-area 2076.64
11 TERRACE WATERPRROFING
Drg Title : 2025-09-18_GVM_A12-08,09-EXT ROOF ,COPING LVL DIAGRAM
Drg Date : 19-09-2025
South block roof 1.0 454.94 454.94
On windows 1.0 8.30 8.30
Drg Title : 2025-09-18_GVM_A12-08,09-EXT ROOF ,COPING LVL DIAGRAM
Drg Date : 19-09-2025
Green roof 1.0 90.97 90.97
Drg Title : 2025-09-18_GVM_A12-08,09-EXT ROOF ,COPING LVL DIAGRAM
Drg Date : 19-09-2025
VIP terrace 1.0 99.10 99.10
Drg Title : 2025-09-18_GVM_A12-08,09-EXT ROOF ,COPING LVL DIAGRAM
Drg Date : 19-09-2025
Exit bridge roof 1.0 196.21 196.21
Above Main entrance 1.0 1626.98 1626.98
Drg Title : 2025-09-18_GVM_A12-08,09-EXT ROOF ,COPING LVL DIAGRAM
Drg Date : 19-09-2025
LOWER GROUND FLOOR
Drg Title : 2025-09-18_GVM_A0-12_SUNK DIAGRAM
Drg Date : 19-09-2025
Male Toilet 1.0 28.23 P-area 0.80 22.58
Female toilet 1.0 25.05 P-area 0.80 20.04
Ind.First Aid 1.0 13.99 P-area 0.80 11.19
Drg Title : 2025-09-18_GVM_A0-12_SUNK DIAGRAM
Drg Date : 19-09-2025
Male Toilet 1.0 22.19 P-area 0.30 6.66
Female toilet 1.0 20.13 P-area 0.30 6.04
Male Toilet 1.0 13.89 P-area 0.80 11.11
Female toilet 1.0 5.54 P-area 0.80 4.43
(Location : ELIPTICAL )
Drg Title : 2025-09-18_GVM_A0-12_SUNK DIAGRAM
Drg Date : 19-09-2025
Male Toilet 1.0 13.65 P-area 0.20 2.73
Female toilet 1.0 31.75 P-area 0.20 6.35
VIP terrace 1.0 101.00 P-area 0.80 80.80
Planter 1.0 39.33 P-area 0.80 31.46
5.1 MANDANA-1 (25MM THICK GRANITE) FLOORING CODE-A12-04 & 1/A14-01
LOWER GROUND LEVEL PLAN
(Location : Intro To Siddhi Gallery,south passage)
Drg Title : GVM_A4_DETAILED PLAN
Drg Date : 11-09-2025
South Passage 1.0 626.00 P-area 626.00
South Passage 1.0 20.46 P-area 20.46
Ded of escalators & staircase area -1.0 95.74 P-area -95.74
GROUND FLOOR LEVEL PLAN
(Location : south passage,toilet passage,pre function lobby,exit passage)
Drg Title : GVM_A4_DETAILED PLAN
Drg Date : 11-09-2025
South Passage 1.0 284.16 P-area 284.16
Deduction of wall -1.0 64.69 P-area -64.69
Toilet passage 1.0 22.79 P-area 22.79
Pre Function lobby 1.0 173.99 P-area 173.99
Exit passage 1.0 163.47 P-area 163.47
1ST FLOOR LEVEL PLAN
(Location : south passage,toilet passage,pre function lobby,exit passage)
Drg Title : GVM_A4_DETAILED PLAN
Drg Date : 11-09-2025
Bountiful gujarat passage 1.0 75.70 P-area 75.70
Bountiful gujarat 1.0 21.99 P-area 21.99
VIP lobby 1.0 114.60 P-area 114.60
South passage 1.0 110.36 P-area 110.36
Exit bridge passage 1.0 14.75 P-area 14.75
Exit bridge 1.0 40.39 3.35 135.29
5.2 T.W WOOD PLANKS 25MM (SOLID WOOD FLOOR) CODE-A12-04 & 6/A14-01
Ground Level Plan
(Location : Temporary gallery,temporary exhibits)
Drg Title : GVM_A4_DETAILED PLAN
Drg Date : 11-09-2025
Temporary Gallery 1.0 380.58 P-area 380.58
Temporary Exhibit 1.0 12.08 P-area 12.08
1ST Floor Level Plan
(Location : vip lounge)
Drg Title : GVM_A4_DETAILED PLAN
Drg Date : 11-09-2025
VIP lounge 1.0 194.14 P-area 194.14
5.3 VDF CONCERETE FLOORING CODE-A12-04 & 2/A14-02
LOWER LEVEL GROUND LEVEL PLAN
(Location : UTSAH GALLERY)
Drg Title : GVM_A4_DETAILED PLAN
Drg Date : 11-09-2025
Utsah Gallery 1.0 571.59 P-area 571.59
Ded Of Column -3.0 0.44 P-area -1.32
GROUND LEVEL PLAN
(Location : UTSAH GALLERY)
Drg Title : GVM_A4_DETAILED PLAN
Drg Date : 11-09-2025
Utsah Gallery 1.0 469.54 P-area 469.54
Ded Of Column -2.0 0.44 P-area -0.88
1ST FLOOR LEVEL PLAN
(Location : UTSAH GALLERY)
Drg Title : GVM_A4_DETAILED PLAN
Drg Date : 11-09-2025
Utsah Gallery 1.0 600.00 P-area 600.00
Ded Of Column -6.0 0.44 P-area -2.64
5.4 25MM THICK SANDSTONE CODE-A12-04 & 1/A14-01
Ground Level Plan
(Location :2250mm Wide Passage Corner Window Lobby )
Drg Title : GVM_A4_DETAILED PLAN
Drg Date : 11-09-2025
2250mm Wide Passage Corner Window Standing Lobby 10.0 3.00 P-area 30.00
1st floor Level Plan
(Location :2250mm Wide Passage Corner Window Lobby )
Drg Title : GVM_A4_DETAILED PLAN
Drg Date : 11-09-2025
2250mm Wide Passage Corner Window Standing Lobby 11.0 3.00 P-area 33.00
5.5 25MM THICK STEEL GREY GRANITE FLOORING CODE-A12-04 & 1/A14-01
Lower Ground Level Plan
(Location : Female Toilet, Male Toilet,wash area)
Drg Title : GVM_A4_DETAILED PLAN
Drg Date : 11-09-2025
Male Toilet 1.0 28.23 P-area 28.23
Female Toilet 1.0 25.05 P-area 25.05
Wash Area 1.0 1.50 P-area 1.50
Passage 1.0 14.00 P-area 14.00
Ground Level Plan
(Location : Female Toilet, Male Toilet)
Drg Title : GVM_A4_DETAILED PLAN
Drg Date : 11-09-2025
Male Toilet 1.0 22.19 P-area 22.19
Janitor 1.0 1.38 P-area 1.38
Female Toilet 1.0 20.13 P-area 20.13
Male Toilet 1.0 13.89 P-area 13.89
Female Toilet 1.0 5.54 P-area 5.54
1st Floor Level Plan
(Location : vip toilet male,vip toilet female)
Drg Title : GVM_A4_DETAILED PLAN
Drg Date : 11-09-2025
VIP Toilet-M 1.0 13.65 P-area 13.65
VIP Toilet-F 1.0 5.50 P-area 5.50
5.6 WOODEN DECK CODE-A12-04 & 12/A14-01
1ST FLOOR LEVEL PLAN
(Location : VIP Terrace)
Drg Title : GVM_A4_DETAILED PLAN
Drg Date : 11-09-2025
VIP Terrace 1.0 93.85 P-area 93.85
5.7 MANDANA-2 (25MM THICK GRANITE) FLOORING CODE-A12-04 & 1/A14-01
Ground Level Plan
(Location : souvenir shop)
Drg Title : GVM_A4_DETAILED PLAN
Drg Date : 11-09-2025
Souvenir Shop 1.0 115.26 P-area 115.26
6 WALL FINISH WORK
6.1 SANDSTONE CLADDING DRG CODE- A12-05 REF : 6/A14-02
Lower Ground Floor
Drg Title : FINISHES DIAGRAM-INT WALLS
Drg No : A12-05
Drg Date : 25-09-2025
South passage 1.0 92.81 4.20 389.81
Fire Door frame 2.0 0.85 4.20 7.14
Into to siddhi gallery (A9-20 sec 30) 1.0 48.30 avg 4.30 207.69
Drg Title : FINISHES DIAGRAM-INT WALLS
Drg No : A12-05
Drg Date : 25-09-2025
Entrance lobby (A06-08 2) 1.0 6.88 6.00 41.25
Exit passage entry 1.0 3.97 4.20 16.68
Exit passage (A6-S wing ) 1.0 2.93 4.20 12.29
Exit passage (A6-S wing) 1.0 35.90 3.74 134.33
Exit passage (A6-S wing) (sec 29 A9-20) 1.0 13.30 4.38 58.24
TEMPORARY EXHIBIT 1.0 24.80 3.60 89.28
Entrance lobby to pre function lobby (A9-15 sec 22) (A06-11 1) 1.0 2.25 6.00 13.50
3600 mm wide pre function passage (A6-12 6) 1.0 22.52 4.20 94.56
Ded Of lift opn -1.0 1.20 2.10 -2.52
3600 mm wide pre function passage (A6-12 7) 1.0 44.48 4.20 186.80
Ded of lift opn -1.0 1.20 2.40 -2.88
South pasage 1.0 97.53 7.20 702.22
Ded Of vitrified tile cladding area -1.0 3.83 4.20 -16.07
Drg Title : FINISHES DIAGRAM-INT WALLS
Drg No : A12-05
Drg Date : 25-09-2025
VIP Lobby 1.0 92.54 p-line 4.20 388.67
Ded of double height wall -1.0 7.80 4.20 -32.76
Ded of double height wall -1.0 5.40 4.20 -22.68
Double height wall 1.0 7.80 8.10 63.18
Double height wall 1.0 5.40 8.10 43.74
Entrance looby 1.0 11.40 1.80 20.52
Entrance lobby to pre function lobby (A9-15 sec 22) (A06-11 1) 1.0 15.70 0.60 9.42
South passage 1.0 17.04 3.60 61.35
South passage (A9-21 SEC 30 ) 1.0 78.57 3.60 282.85
BOUNTIFUL GUJARAT (SEC 29 A9-20) 1.0 14.25 4.80 68.40
Double height fire escape (SEC 29 A9-20) 1.0 23.60 4.20 99.11
6.2 FIRE RATED GYPSUM BOARD + PAINT DRG CODE- A12-05 REF : 17/A14-02
Lower Ground Floor
Drg Title : FINISHES DIAGRAM-INT WALLS
Drg No : A12-05
Drg Date : 25-09-2025
Introduction to siddhi gallery 1.0 40.68 3.60 146.43
Drg Title : FINISHES DIAGRAM-INT WALLS
Drg No : A12-05
Drg Date : 25-09-2025
TEMPORARY GALLERY 1.0 91.83 4.80 440.76
UTSAH GALLERY 1.0 97.71 4.80 469.03
Drg Title : FINISHES DIAGRAM-INT WALLS
Drg No : A12-05
Drg Date : 25-09-2025
UTSAH GALLERY 1.0 100.32 4.80 481.54
6.3 WOODEN PANELING DRG CODE- A12-05 REF : 7/A14-02
Drg Title : FINISHES DIAGRAM-INT WALLS
Drg No : A12-05
Drg Date : 25-09-2025
A7-10 Cladding (side) (L.G.F to G.F) 2.0 113.87 p-area 227.74
Entrance lobby 2.0 1.50 4.80 14.40
Temporary gallery entrance frame claddding 2.0 1.02 3.00 6.15
Utsahh Gallery frame cladding 2.0 1.00 3.60 7.20
Drg Title : FINISHES DIAGRAM-INT WALLS
Drg No : A12-05
Drg Date : 25-09-2025
VIP Lounge 1.0 60.50 p-line 4.20 254.10
A7-10 Cladding (side) (G.F To F.F) 2.0 83.45 p-area 166.90
6.4 MANDANA STONE-3 CLADDING DRG CODE- A12-05 REF : 6/A14-02
Lower Ground Floor
Drg Title : FINISHES DIAGRAM-INT WALLS
Drg No : A12-05
Drg Date : 25-09-2025
South Passage 1.0 37.33 4.20 156.78
Drg Title : FINISHES DIAGRAM-INT WALLS
Drg No : A12-05
Drg Date : 25-09-2025
South Passage 1.0 18.24 3.00 54.71
Pre function lobby 1.0 4.15 4.20 17.43
Pre function lobby 1.0 5.40 7.20 38.88
Pre function lobby 1.0 4.80 5.10 24.48
Exit Passage (A06-16 3) 1.0 26.53 avg 3.51 93.00
Exit Passage (A06-16 3) (sec 29 a9-20) 1.0 11.23 avg 4.38 49.15
Drg Title : FINISHES DIAGRAM-INT WALLS
Drg No : A12-05
Drg Date : 25-09-2025
South passage 1.0 44.99 3.60 161.96
Bountiful gujarat 1.0 7.35 4.80 35.28
Double height exit passage (sec 29 A9-20) -1.0 20.61 4.20 -86.55
Exit bridge ( sec 31 A9-21) 2.0 43.16
6.5 GRANITE CLADDING DRG CODE- A12-05 REF : 6/A14-02
Lower Ground Floor
Drg Title : FINISHES DIAGRAM-INT WALLS
Drg No : A12-05
Drg Date : 25-09-2025
Ded Of Lift opn -1.0 2.80 2.40 -6.72
Ded Of lift opn -1.0 1.10 2.40 -2.64
Drg Title : FINISHES DIAGRAM-INT WALLS
Drg No : A12-05
Drg Date : 25-09-2025
Ded Of lift opn -1.0 2.80 2.40 -6.72
Drg Title : FINISHES DIAGRAM-INT WALLS
Drg No : A12-05
Drg Date : 25-09-2025
Ded Of lift opn -1.0 2.80 2.40 -6.72
6.6 S.S CLADDING DRG CODE- A12-05 REF : 13/A14-02
Drg Title : FINISHES DIAGRAM-INT WALLS
Drg No : A12-05
Drg Date : 25-09-2025
Entrance lobby 1.0 21.00 2.40 50.40
6.6 S.S CLADDING DRG CODE- A12-05 REF : 13/A14-02
Drg Title : FINISHES DIAGRAM-INT WALLS
Drg No : A12-05
Drg Date : 25-09-2025
on columns at entrance lobby 6.0 2.51 6.06 91.36
6.7 VITRIFIED TILES CLADDING DRG CODE- A12-05 REF : 8/A14-02
Lower Ground Floor
Drg Title : FINISHES DIAGRAM-INT WALLS
Drg No : A12-05
Drg Date : 25-09-2025
Janitor room 1.0 5.21 3.60 18.76
Drg Title : FINISHES DIAGRAM-INT WALLS
Drg No : A12-05
Drg Date : 25-09-2025
F-toilet 1.0 24.50 P-line 3.60 88.19
m-toilet 1.0 25.89 P-line 3.60 93.19
M-Toilet 1.0 19.35 P-line 3.60 69.66
Drg Title : FINISHES DIAGRAM-INT WALLS
Drg No : A12-05
Drg Date : 25-09-2025
M-Toilet 1.0 19.35 P-line 3.60 69.66
8 FALSE CEILING WORK
8.1 PUNCHED GYPSUM + ACOUSTIC LINING CODE-A12-07 & 3/A14-04
LOWER GROUND LEVEL PLAN
(Location : Paint & Spray,Exhibition Prep Clean Rm)
Drg Title : GVM_A12_07_Int Ceiling Diagram
Drg Date : 18-09-2025
Paint 7 Spray 1.0 50.36 P-area 50.36
Exhibition Prep Clean Rm 1.0 7.22 6.30 45.49
Ded OF Column -1.0 0.75 0.75 -0.56
GROUND FLOOR LEVEL PLAN
(Location : Main Entrance)
Drg Title : GVM_A12_07_Int Ceiling Diagram
Drg Date : 18-09-2025
Main Entrance 1.0 440.64 P-area 440.64
8.3 GYPSUM + ACOUSTIC LINING CODE-A12-07 & 1/A14-04
LOWER GROUND LEVEL PLAN
(Location : intro to Siddhi Gallery,South passage)
Drg Title : GVM_A12_07_Int Ceiling Diagram
Drg Date : 18-09-2025
South pssage 1.0 629.83 P-area 629.83
Ded Of Area -1.0 87.45 P-area -87.45
GROUND FLOOR LEVEL PLAN
(Location : 2250 m Wide Passage,Pre function Lobby,pre function lobby,entrance lobby )
Drg Title : GVM_A12_07_Int Ceiling Diagram
Drg Date : 18-09-2025
2.250 m wide Passage 1.0 342.21 P-area 342.21
Pre Function Lobby 1.0 29.27 P-area 29.27
Exit Passage 1.0 146.79 P-area 146.79
Entrance Lobby 1.0 157.37 P-area 157.37
Aluminium Grill Area 1.0 20.89 P-area 20.89
Aluminium Grill Area 1.0 15.93 P-area 15.93
Souvenir Shop 1.0 112.71 P-area 112.71
1ST FLOOR LEVEL PLAN
(Location :VIP LOUNGE,Vip Lobby,South Passage,souvenir shop,pre function lobby)
Drg Title : GVM_A12_07_Int Ceiling Diagram
Drg Date : 18-09-2025
VIP Lounge 1.0 120.00 P-area 120.00
Bridge Bw South & North Block 1.0 86.38 P-area 86.38
Bridge Bw South & Eliptical 1.0 144.77 P-area 144.77
Vip Lobby 1.0 412.96 P-area 412.96
Pre-f Lobby 1.0 46.86 P-area 46.86
Souvenir Shop 1.0 18.74 P-area 18.74
8.6 WOODEN SLATS CODE-A12-07 & 10/A14-04
1ST FLOOR LEVEL PLAN
(Location : VIP Lounge)
Drg Title : GVM_A12_07_Int Ceiling Diagram
Drg Date : 18-09-2025
VIP Lounge 1.0 55.27 P-area 55.27
8.7 FRP CANOPY CODE-A12-07 & 7/A14-04
GROUND FLOOR LEVEL PLAN
(Location : Entrance )
Drg Title : GVM_A12_07_Int Ceiling Diagram
Drg Date : 18-09-2025
Entrance Lobby 1.0 476.38 P-area 476.38
5.9 25MM THICK KOTA STONE FLOORING CODE-A12-04 & 4/A14-01
Lower Ground Level Plan
(Location : DG AREA,PUMP ROOM,LT PANEL AREA,Pump Room,FRESH AIR PASSAGE)
Drg Title : GVM_A4_DETAILED PLAN
Drg Date : 11-09-2025
Paint & spray 1.0 50.36 P-area 50.36
AHU 1.0 43.63 P-area 43.63
BOH Passage 1.0 36.28 P-area 36.28
AHU 1.0 24.36 P-area 24.36
Pump Room 1.0 10.84 P-area 10.84
Ground Level Plan
(Location : AHU,SERVICE PASSAGE,Elv-Ict,FF Shaft)
Drg Title : GVM_A4_DETAILED PLAN
Drg Date : 11-09-2025
AHU 1.0 25.71 P-area 25.71
Service Passage 1.0 96.99 P-area 96.99
ELV-ICT 1.0 2.51 P-area 2.51
ST-F1 Lobby 1.0 2.21 P-area 2.21
FF Shaft 1.0 0.85 P-area 0.85
(Location : lobby,AHU,Pantry,Service Passage,ELV-ICT,SHAFT,STORE)
Drg Title : GVM_A4_DETAILED PLAN
Drg Date : 11-09-2025
AHU Lobby 1.0 99.41 P-area 99.41
Lobby 1.0 10.55 P-area 10.55
Lobby 1.0 4.46 P-area 4.46
Service Passage 1.0 98.42 P-area 98.42
AHU 1.0 17.22 P-area 17.22
ELV-ICT 1.0 3.62 P-area 3.62
Shaft passage 1.0 1.93 1.08 2.08
AHU 1.0 47.63 P-area 47.63
Store 1.0 14.51 P-area 14.51
5.10 SEALED CONCRETE FLOORING CODE-A12-04 & 13A/A14-01
Lower Gorund Floor
(Location : ELEV-E-05,SHAFT,ElEV-G5,Elev-G1,Elev-02,Elev-G4)
Drg Title : GVM_A4_DETAILED PLAN
Drg Date : 11-09-2025
Plumbing Shaft 1.0 1.45 0.93 1.35
Duct 1.0 6.27 P-area 6.27
Duct 1.0 3.39 P-area 3.39
5.12 S.S WALK OF MATT CODE-A12-04 & 8/A14-01
Lower Ground Level Plan
(Location :Pre Function court )
Drg Title : GVM_A4_DETAILED PLAN
Drg Date : 11-09-2025
At Ramp 1.0 4.95 P-area 4.95
Siddhi Gallery Passage entry 1.0 3.83 P-area 3.83
Boh passage Entry 1.0 2.13 P-area 2.13
Ground Level Plan
Drg Title : GVM_A4_DETAILED PLAN
Drg Date : 11-09-2025
Pre function court 1.0 4.32 P-area 4.32
1ST Floor Level Plan
(Location : Vip Terrace )
Drg Title : GVM_A4_DETAILED PLAN
Drg Date : 11-09-2025
Vip Terrace 2.0 3.75 P-area 7.50
5.15 RAISED ANTI-STATIC FLOORING CODE-A12-04 & 9B/A14-01
Drg Title : GVM_A4_DETAILED PLAN
Drg Date : 11-09-2025
5.18 GRAY GRANITE FLOORING CODE-A12-04 & 1/A14-01
Lower Ground Floor
Drg Title : GVM_A4_DETAILED PLAN
Drg Date : 11-09-2025
EXHIBITION PREP CLEAN RM 1.0 7.22 6.30 45.49
Ded Of Column -1.0 0.75 0.75 -0.56
EXHIBITION PREP DIRTY RM 1.0 16.10 7.22 116.24
Ded Of Column -2.0 0.75 0.75 -1.13
5.20 25MM THICK KOTA STONE FLOORING CODE-A12-04 & 4/A14-01 (LOCATION : Staircase)
Lower Ground Level Plan As per A7_staricase & ramp details
(Location : Stairacse)
Drg Title : GVM_A4_DETAILED PLAN
Drg Date : 11-09-2025
Floor Landing-01 (-8400mm) frm detailed plan 1.0 33.59 P-area 33.59
Mid-landing-4 (-6600mm) 1.0 8.90 P-area 8.90
Mid-landing-3 (-4800mm) 1.0 21.01 P-area 21.01
Mid-landing-4 (-3000mm) 1.0 8.90 P-area 8.90
Floor Landing-01 (-8400mm) frm detailed plan 1.0 20.24 P-area 20.24
Floor Landing-01 (-8400mm) frm detailed plan 1.0 10.13 P-area 10.13
Mid-landing-2 (-7500mm) 1.0 6.87 P-area 6.87
Mid-landing-3 (-6450mm) 1.0 5.75 P-area 5.75
Mid-landing-4 (-5400mm) 1.0 5.43 P-area 5.43
Mid-landing-5 (-4350mm) 1.0 6.33 P-area 6.33
Mid-landing-6 (-3300mm) 1.0 6.37 P-area 6.37
Mid-landing-7 (-2250mm) 1.0 5.58 P-area 5.58
Ground Level Plan As per A7_staricase & ramp details
(Location : Stairacse)
Drg Title : GVM_A4_DETAILED PLAN
Drg Date : 11-09-2025
Floor Landing-05 (-1200mm) 1.0 10.80 P-area 10.80
Mid-landing-6 (+600mm) 1.0 8.90 P-area 8.90
Mid-landing-7 (+2400mm) 1.0 8.88 P-area 8.88
Mid-landing-8 (+4200mm) 1.0 9.49 P-area 9.49
Floor Landing-08 (-1200mm) frm detailed plan 1.0 7.38 P-area 7.38
Mid-landing-9 (-600mm) 1.0 6.97 P-area 6.97
Mid-landing-10 (+300mm) 1.0 4.82 P-area 4.82
Mid-landing-11 (+1500mm) 1.0 6.76 P-area 6.76
Mid-landing-12 (+2100mm) 1.0 7.57 P-area 7.57
Mid-landing-13 (+3300mm) 1.0 3.57 P-area 3.57
Mid-landing-14 (+4650mm) 1.0 4.97 P-area 4.97
1st Level Plan As per A7_staricase & ramp details
(Location : Stairacse)
Drg Title : GVM_A4_DETAILED PLAN
Drg Date : 11-09-2025
Floor Landing-09 (+6000mm) frm detailed plan 1.0 10.82 P-area 10.82
Mid-landing-10 (+7500mm) 1.0 10.68 P-area 10.68
Mid-landing-11 (+9000mm) 1.0 9.50 P-area 9.50
Mid-landing-12 (+10650mm) 1.0 9.49 P-area 9.49
Floor Landing-08 (-1200mm) frm detailed plan 1.0 5.91 P-area 5.91
2nd Level Plan As per A7_staricase & ramp details
(Location : Stairacse)
Drg Title : GVM_A4_DETAILED PLAN
Drg Date : 11-09-2025
Floor Landing-09 (+6000mm) frm detailed plan 1.0 10.27 P-area 10.27
5.21 MANDANA-1 (25MM THICK GRANITE) STAIRCASE FLOORING CODE-A12-04 & 1/A14-01
Lower Ground Level Plan As per A7_staricase & ramp details
(Location : Stairacse)
Drg Title : GVM_A4_DETAILED PLAN
Drg Date : 11-09-2025
Floor Landing-01 (-8400mm) frm detailed plan 1.0 2.05 1.03 2.12
Ground Level Plan As per A7_staricase & ramp details
(Location : Stairacse)
Drg Title : GVM_A4_DETAILED PLAN
Drg Date : 11-09-2025
5.22 25MM THICK KOTA STONE-TREADS CODE-A12-04 & 4/A14-01 (LOCATION : Staircase)
Lower Ground Level Plan
(Location : Stairacse)
Drg Title : GVM_A4_DETAILED PLAN
Drg Date : 11-09-2025
Ground Level Plan As per A7_staricase & ramp details
(Location : Stairacse)
Drg Title : GVM_A4_DETAILED PLAN
Drg Date : 11-09-2025
1st Level Plan As per A7_staricase & ramp details
(Location : Stairacse)
Drg Title : GVM_A4_DETAILED PLAN
Drg Date : 11-09-2025
5.22 MANDANA-1 (25MM THICK GRANITE) TREADS CODE-A12-04 & 1/A14-01
Lower Ground Level Plan
(Location : Stairacse)
Drg Title : GVM_A4_DETAILED PLAN
Drg Date : 11-09-2025
Ground Level Plan
(Location : Stairacse)
Drg Title : GVM_A4_DETAILED PLAN
Drg Date : 11-09-2025
5.22 450mm WIDE MANDANA-1 (25MM THICK GRANITE) TREADS CODE-A12-04 & 1/A14-01
Ground Level Plan
(Location : Stairacse)
Drg Title : GVM_A4_DETAILED PLAN
Drg Date : 11-09-2025
5.22 450mm WIDE MANDANA-1 (25MM THICK GRANITE) RISERS CODE-A12-04 & 1/A14-01
Ground Level Plan
(Location : Stairacse)
Drg Title : GVM_A4_DETAILED PLAN
Drg Date : 11-09-2025
5.23 25MM THICK KOTA STONE-RISERS CODE-A12-04 & 4/A14-01 (LOCATION : Staircase)
Lower Ground Level Plan
(Location : Stairacse)
Drg Title : GVM_A4_DETAILED PLAN
Drg Date : 11-09-2025
Ground Level Plan As per A7_staricase & ramp details
(Location : Stairacse)
Drg Title : GVM_A4_DETAILED PLAN
Drg Date : 11-09-2025
1st Level Plan As per A7_staricase & ramp details
(Location : Stairacse)
Drg Title : GVM_A4_DETAILED PLAN
Drg Date : 11-09-2025
5.24 MANDANA-1 (25MM THICK GRANITE) RISERS CODE-A12-04 & 1/A14-01
Lower Ground Level Plan
(Location : Stairacse)
Drg Title : GVM_A4_DETAILED PLAN
Drg Date : 11-09-2025
Ground Level Plan
(Location : Stairacse)
Drg Title : GVM_A4_DETAILED PLAN
Drg Date : 11-09-2025
6 WALL FINISH WORK
6.11 GYPSUM PLASTER + PAINT DRG CODE- A12-05 REF : 10/A14-02
Lower Ground Floor
Drg Title : FINISHES DIAGRAM-INT WALLS
Drg No : A12-05
Drg Date : 25-09-2025
EXHIBITION PREP CLEAN RM 2.0 6.30 3.60 45.36
EXHIBITION EQUIPTMENT 2.0 16.10 3.60 115.92
BOH Passage 1.0 28.93 2.70 78.11
Drg Title : FINISHES DIAGRAM-INT WALLS
Drg No : A12-05
Drg Date : 25-09-2025
SERVICE PASSAGE 1.0 38.60 3.60 138.96
ELV-ICT 1.0 7.03 P-line 6.00 42.16
PLUMBING SHAFT (SEC25 A9-17 ) 2.0 1.52 6.00 18.24
FF+HVAC SHAFT 2.0 2.48 6.00 29.71
Drg Title : FINISHES DIAGRAM-INT WALLS
Drg No : A12-05
Drg Date : 25-09-2025
Souvenir shop (A9-14 SEC 39) 1.0 34.09 2.25 76.70
SERVICE PASSAGE 1.0 41.82 3.60 150.53
6.12 SOUND ATTENAUTION DRG CODE- A12-05 REF : 11/A14-02
Lower Ground Floor
Drg Title : FINISHES DIAGRAM-INT WALLS
Drg No : A12-05
Drg Date : 25-09-2025
Drg Title : FINISHES DIAGRAM-INT WALLS
Drg No : A12-05
Drg Date : 25-09-2025
Drg Title : FINISHES DIAGRAM-INT WALLS
Drg No : A12-05
Drg Date : 25-09-2025
6.16 PLASTER FINISH DRG CODE- A12-05 REF : 15/A14-02
Lower Ground Floor
Drg Title : FINISHES DIAGRAM-INT WALLS
Drg No : A12-05
Drg Date : 25-09-2025
PLUMBING SHAFT (A9-17) 2.0 1.45 7.30 21.17
Drg Title : FINISHES DIAGRAM-INT WALLS
Drg No : A12-05
Drg Date : 25-09-2025
Plumbing Shaft 2.0 0.60 6.00 7.20
PLUMBING SHAFT (A9-17) 2.0 1.45 6.00 17.40
Drg Title : FINISHES DIAGRAM-INT WALLS
Drg No : A12-05
Drg Date : 25-09-2025
Plumbing Shaft 2.0 0.60 7.00 8.40
PLUMBING SHAFT (A9-17) 2.0 1.45 7.00 20.30
6.17 ALUMINIUM CLADDING DRG CODE- A12-05 REF : 12/A14-02
Drg Title : FINISHES DIAGRAM-INT WALLS
Drg No : A12-05
Drg Date : 25-09-2025
Entrance door frame cladding 4.0 2.80 3.00 33.60
6 SKIRTING WORK
6.1 WOODEN SKIRTING CODE-A12-06 & 3/A14-03
LOWER GROUND LEVEL PLAN
(Location : Utsah Gallery,Intro to Siddhi gallery)
Drg Title : GVM_A12_07_Int Ceiling Diagram
Drg Date : 18-09-2025
Utsah Gallery 1.0 113.54 P-Line 0.00
On Column 3.0 3.46 0.00
Intro to Siddhi gallery (Passage) 1.0 40.20 40.20
GROUND LEVEL PLAN
(Location : Tem gallery,Utsah Gallery)
Drg Title : GVM_A12_07_Int Ceiling Diagram
Drg Date : 18-09-2025
Temporary gallery 1.0 91.83 P-Line 0.00
Lobby 2.0 1.47 P-Line 0.00
Utsah Gallery 1.0 97.71 P-Line 0.00
On Column 2.0 3.45 0.00
GROUND LEVEL PLAN
(Location : Utsah Gallery)
Drg Title : GVM_A12_07_Int Ceiling Diagram
Drg Date : 18-09-2025
Utsah Gallery 1.0 11.69 P-Line 11.69
On Columns 6.0 3.05 18.30
6.2 KOTA STONE SKIRTING (LOADING BAY) CODE-A12-06 & 2/A14-03
LOWER GROUND LEVEL PLAN
(Location : Loading bay)
Drg Title : GVM_A12_07_Int Ceiling Diagram
Drg Date : 18-09-2025
Loading bay 1.0 17.05 P-Line 17.05
6.3 KOTA STONE SKIRTING CODE-A12-06 & 1/A14-03
LOWER GROUND LEVEL PLAN
(Location : exhibition prep clean rm,Paint 7 spray ,Pump room,AHU,BOH Passage)
Drg Title : GVM_A12_07_Int Ceiling Diagram
Drg Date : 18-09-2025
Exhibition Prep Clean Rm 2.0 6.30 12.60
On Column 1.0 3.00 3.00
Tool storage 2.0 16.10 32.20
On Column 2.0 3.00 6.00
Panit & spray 1.0 28.75 28.75
Pump Room 1.0 14.24 14.24
BOH Passage 1.0 28.93 28.93
GROUND LEVEL PLAN
(Location : Service passage,AHU)
Drg Title : GVM_A12_07_Int Ceiling Diagram
Drg Date : 18-09-2025
Service Passage 1.0 21.56 21.56
1ST FLOOR LEVEL PLAN
(Location : AHU,SERVICE PASSAGE,PANTRY,STORE)
Drg Title : GVM_A12_07_Int Ceiling Diagram
Drg Date : 18-09-2025
AHU 1.0 49.62 P-line 49.62
Electric panel 1.0 12.59 12.59
Electric panel 1.0 8.90 8.90
Ded Of opn -1.0 2.03 -2.03
Service Passage 1.0 44.86 44.86
6.4 S.S BASE (COLUMN) CODE-A12-06 & 4/A14-03
LOWER GROUND LEVEL PLAN
(Location : Exhibits & Collection,Service Shipping rec,Metering Kisok,Waste Management,UPS Bank,Sec lockers,Collection storage)
Drg Title : GVM_A12_07_Int Ceiling Diagram
Drg Date : 18-09-2025
5.23 25MM THICK KOTA STONE-SKIRTING CODE-A12-04 & 4/A14-01 (LOCATION : Staircase)
Lower Ground Level Plan As per A7_staricase & ramp details
(Location : Stairacse)
Drg Title : GVM_A4_DETAILED PLAN
Drg Date : 11-09-2025
Floor Landing-01 (-8400mm) frm detailed plan 1.0 25.86 P-line 25.86
Mid-landing-4 (-6600mm) 1.0 8.75 P-line 8.75
Mid-landing-3 (-4800mm) 1.0 21.79 P-line 21.79
Mid-landing-4 (-3000mm) 1.0 8.75 P-line 8.75
Floor Landing-01 (-8400mm) frm detailed plan 1.0 19.87 P-line 19.87
Floor Landing-01 (-8400mm) frm detailed plan 1.0 14.13 P-line 14.13
Mid-landing-2 (-7500mm) 1.0 6.49 P-line 6.49
Mid-landing-3 (-6450mm) 1.0 5.77 P-line 5.77
Mid-landing-4 (-5400mm) 1.0 5.66 P-line 5.66
Mid-landing-5 (-4350mm) 1.0 5.89 P-line 5.89
Mid-landing-6 (-3300mm) 1.0 6.43 P-line 6.43
Mid-landing-7 (-2250mm) 1.0 5.86 P-line 5.86
Ground Level Plan As per A7_staricase & ramp details
(Location : Stairacse)
Drg Title : GVM_A4_DETAILED PLAN
Drg Date : 11-09-2025
Floor Landing-05 (-1200mm) 1.0 10.66 P-line 10.66
Mid-landing-6 (+600mm) 1.0 8.75 P-line 8.75
Mid-landing-7 (+2400mm) 1.0 8.74 P-line 8.74
Mid-landing-8 (+4200mm) 1.0 9.34 P-line 9.34
Floor Landing-08 (-1200mm) frm detailed plan 1.0 7.14 P-line 7.14
Mid-landing-9 (-600mm) 1.0 7.01 P-line 7.01
Mid-landing-10 (+300mm) 1.0 5.16 P-line 5.16
Mid-landing-11 (+1500mm) 1.0 6.36 P-line 6.36
Mid-landing-12 (+2100mm) 1.0 7.77 P-line 7.77
Mid-landing-13 (+3300mm) 1.0 4.38 P-line 4.38
Mid-landing-14 (+4650mm) 1.0 4.86 P-line 4.86
1st Level Plan As per A7_staricase & ramp details
(Location : Stairacse)
Drg Title : GVM_A4_DETAILED PLAN
Drg Date : 11-09-2025
Floor Landing-09 (+6000mm) frm detailed plan 1.0 10.68 P-line 10.68
Mid-landing-10 (+7500mm) 1.0 10.69 P-line 10.69
Mid-landing-11 (+9000mm) 1.0 9.50 P-line 9.50
Mid-landing-12 (+10650mm) 1.0 9.34 P-line 9.34
Floor Landing-08 (-1200mm) frm detailed plan 1.0 6.63 P-area 6.63
2nd Level Plan As per A7_staricase & ramp details
(Location : Stairacse)
Drg Title : GVM_A4_DETAILED PLAN
Drg Date : 11-09-2025
Floor Landing-09 (+6000mm) frm detailed plan 1.0 10.10 P-area 10.10
5.23 MANDANA-1 (25MM THICK GRANITE) STAIRCASE SKIRITING CODE-A12-04 & 1/A14-01
Lower Ground Level Plan
(Location : Stairacse)
Drg Title : GVM_A4_DETAILED PLAN
Drg Date : 11-09-2025
Floor Landing-01 (-8400mm) frm detailed plan 2.0 1.04 2.08
Mid-landing-14 (-6600mm) 2.0 1.50 3.00
Mid-landing-28 (-4800mm) 2.0 1.50 3.00
5.24 25MM THICK KOTA STONE-INCLINED SKIRTING CODE-A12-04 & 4/A14-01 (LOCATION : Staircase)
Lower Ground Level Plan
(Location : Stairacse)
Drg Title : GVM_A4_DETAILED PLAN
Drg Date : 11-09-2025
Ground Level Plan As per A7_staricase & ramp details
(Location : Stairacse)
Drg Title : GVM_A4_DETAILED PLAN
Drg Date : 11-09-2025
1st Level Plan As per A7_staricase & ramp details
(Location : Stairacse)
Drg Title : GVM_A4_DETAILED PLAN
Drg Date : 11-09-2025
5.23 MANDANA-1 (25MM THICK GRANITE) STAIRCASE INCLINED SKIRITING CODE-A12-04 & 1/A14-01
8 FALSE CEILING WORK
8.9 MINERAL FIBRE GRID CEILING 600X600 CODE-A12-07 & 2/A14-04
LOWER GROUND FLOOR LEVEL PLAN
(Location : tool storage )
Drg Title : GVM_A12_07_Int Ceiling Diagram
Drg Date : 18-09-2025
Tool Storage 1.0 16.10 7.22 116.24
Ded Of Columns -2.0 0.75 0.75 -1.13
GROUND FLOOR LEVEL PLAN
(Location : Service Passage )
Drg Title : GVM_A12_07_Int Ceiling Diagram
Drg Date : 18-09-2025
Service passage 1.0 96.99 P-area 96.99
1ST FLOOR LEVEL PLAN
(Location : Service Passage )
Drg Title : GVM_A12_07_Int Ceiling Diagram
Drg Date : 18-09-2025
Service passage 1.0 98.42 P-area 98.42
8.12 METAL CEILING CODE-A12-07 & 11/A14-04
1st FLOOR LEVEL PLAN
(Location : Pantry )
Drg Title : GVM_A12_07_Int Ceiling Diagram
Drg Date : 18-09-2025
Pantry 1.0 32.19 P-area 32.19
8.13 PLASTER + PAINT CODE-A12-07 & 5/A14-04
LOWER GROUND LEVEL PLAN
(Location : BOH Passage )
Drg Title : GVM_A12_07_Int Ceiling Diagram
Drg Date : 18-09-2025
BOH Passage 1.0 36.25 P-area 36.25
1st FLOOR LEVEL PLAN
(Location : Store
Drg Title : GVM_A12_07_Int Ceiling Diagram
Drg Date : 18-09-2025
Store 1.0 14.51 P-area 14.51
8.14 SOUND ATTENUATION CODE-A12-07 & 7/A14-04
LOWER GROUND LEVEL PLAN
(Location : AHU)
Drg Title : GVM_A12_07_Int Ceiling Diagram
Drg Date : 18-09-2025
AHU 1.0 43.63 P-area 43.63
AHU 1.0 24.36 P-area 24.36
AHU 1.0 10.84 P-area 10.84
GROUND FLOOR LEVEL PLAN
(Location : AHU )
Drg Title : GVM_A12_07_Int Ceiling Diagram
Drg Date : 18-09-2025
AHU 1.0 25.71 P-area 25.71
1st FLOOR LEVEL PLAN
(Location : AHU )
Drg Title : GVM_A12_07_Int Ceiling Diagram
Drg Date : 18-09-2025
AHU 1.0 99.41 P-area 99.41
AHU 1.0 47.63 P-area 47.63
8.1 GYPSUM + PAINT CODE-A12-07 & 5/A14-04
LOWER GROUND LEVEL PLAN
(Location : M-toilet,F-Toilet)
Drg Title : GVM_A12_07_Int Ceiling Diagram
Drg Date : 18-09-2025
M-Toilet 1.0 28.23 P-area 28.23
J.Room 1.0 1.50 P-area 1.50
F-Toilet 1.0 25.05 P-area 25.05
GROUND FLOOR LEVEL PLAN
(Location : Female Toilet,Male Toilet)
Drg Title : GVM_A12_07_Int Ceiling Diagram
Drg Date : 18-09-2025
Female Toilet 1.0 20.13 P-area 20.13
Male Toilet 1.0 22.19 P-area 22.19
Janitor 1.0 1.38 P-area 1.38
Male Toilet 1.0 13.89 P-area 13.89
Female Toilet 1.0 5.54 P-area 5.54
1ST FLOOR LEVEL PLAN
(Location : Vip Toilet-M,Vip Toilet-Female)
Drg Title : GVM_A12_07_Int Ceiling Diagram
Drg Date : 18-09-2025
VIP Toilet-Female 1.0 5.69 P-area 5.69
VIP Toilet-Male 1.0 13.65 13.65
8.16 BARRIOL CEILING CODE-A12-07 & 20/A14-04
GROUND FLOOR LEVEL PLAN
(Location : Souvenir Shop)
Drg Title : GVM_A12_07_Int Ceiling Diagram
Drg Date : 18-09-2025
1ST FLOOR LEVEL PLAN
(Location : VIP Lounge)
Drg Title : GVM_A12_07_Int Ceiling Diagram
Drg Date : 18-09-2025
VIP Lounge 1.0 8.56 P-area 8.56
15.13 GRANITE COUNTER
Lower ground floor
(Location : ELIPTICAL )
Drg Title : 2025-09-18_GVM_A12-12-RAILING DIAGRAM
Drg Date : 19-09-2025
FACIA - GRANITE
(Location : ELIPTICAL )
Drg Title : 2025-09-18_GVM_A12-12-RAILING DIAGRAM
Drg Date : 19-09-2025
(Location : ELIPTICAL )
Drg Title : 2025-09-18_GVM_A12-12-RAILING DIAGRAM
Drg Date : 19-09-2025
Toilet , 6.0 6.00
GRANITE COUNTER
(Location : ELIPTICAL )
Drg Title : 2025-09-18_GVM_A12-12-RAILING DIAGRAM
Drg Date : 19-09-2025
FACIA - GRANITE
(Location : ELIPTICAL )
Drg Title : 2025-09-18_GVM_A12-12-RAILING DIAGRAM
Drg Date : 19-09-2025
(Location : ELIPTICAL )
Drg Title : 2025-09-18_GVM_A12-12-RAILING DIAGRAM
Drg Date : 19-09-2025
Toilet , 12.0 12.00
GRANITE COUNTER
(Location : ELIPTICAL )
Drg Title : 2025-09-18_GVM_A12-12-RAILING DIAGRAM
Drg Date : 19-09-2025
FACIA - GRANITE
(Location : ELIPTICAL )
Drg Title : 2025-09-18_GVM_A12-12-RAILING DIAGRAM
Drg Date : 19-09-2025
Toilet 2.0 2.70 5.40
(Location : ELIPTICAL )
Drg Title : 2025-09-18_GVM_A12-12-RAILING DIAGRAM
Drg Date : 19-09-2025
Toilet , 6.0 6.00
GRANITE COUNTER
(Location : ELIPTICAL )
Drg Title : 2025-09-18_GVM_A12-12-RAILING DIAGRAM
Drg Date : 19-09-2025
FACIA - GRANITE
(Location : ELIPTICAL )
Drg Title : 2025-09-18_GVM_A12-12-RAILING DIAGRAM
Drg Date : 19-09-2025
Toilet 1.0 1.20 1.20
(Location : ELIPTICAL )
Drg Title : 2025-09-18_GVM_A12-12-RAILING DIAGRAM
Drg Date : 19-09-2025
Toilet , 4.0 4.00
LOWER GROUND FLOOR
(Location : ELIPTICAL )
Drg Title : GVM_A4_DETAILES PLAN_10-09-25
Drg Date : 19-09-2025
L-Shape 4.0 4.00
L-Shape 3.0 3.00
(Location : ELIPTICAL )
Drg Title : GVM_A4_DETAILES PLAN_10-09-25
Drg Date : 19-09-2025
L-Shape 2.0 2.00
L-Shape 2.0 2.00
L-Shape 0.0 0.00
L-Shape 1.0 1.00
(Location : ELIPTICAL )
Drg Title : GVM_A4_DETAILES PLAN_10-09-25
Drg Date : 19-09-2025
L-Shape 0.0 0.00
L-Shape 1.0 1.00
LOWER GROUND FLOOR
Drg Title : GVM_A4_DETAILES PLAN_10-09-25
Drg Date : 19-09-2025
I-Shape 1.0 1.00
I-Shape 1.0 1.00
(Location : ELIPTICAL )
Drg Title : GVM_A4_DETAILES PLAN_10-09-25
Drg Date : 19-09-2025
I-Shape 2.0 2.00
I-Shape 1.0 1.00
I-Shape 1.0 1.00
I-Shape 1.0 1.00
(Location : ELIPTICAL )
Drg Title : GVM_A4_DETAILES PLAN_10-09-25
Drg Date : 19-09-2025
I-Shape 1.0 1.00
I-Shape 1.0 1.00
URINAL PARTITION
LOWER GROUND FLOOR
(Location : ELIPTICAL )
Drg Title : GVM_A4_DETAILES PLAN_10-09-25
Drg Date : 19-09-2025
(Location : ELIPTICAL )
Drg Title : GVM_A4_DETAILES PLAN_10-09-25
Drg Date : 19-09-2025
(Location : ELIPTICAL )
Drg Title : GVM_A4_DETAILES PLAN_10-09-25
Drg Date : 19-09-2025
9 PARAPET FINISH
9.1 2 SIDE PLASTER
Drg Title : 2025-09-18_GVM_A12-08,09-EXT ROOF ,COPING LVL DIAGRAM
Drg Date : 19-09-2025
South building 2.0 14.75 1.10 32.44
9.2 1 SIDE STONE CLADDING
LOWER GROUND FLOOR
Drg Title : 2025-09-18_GVM_A12-08,09-EXT ROOF ,COPING LVL DIAGRAM
Drg Date : 19-09-2025
South building 1.0 86.04 0.49 42.16
Drg Title : 2025-09-18_GVM_A12-08,09-EXT ROOF ,COPING LVL DIAGRAM
Drg Date : 19-09-2025
South building 1.0 27.03 0.49 13.24
South building 1.0 13.12 0.49 6.43
Drg Title : 2025-09-18_GVM_A12-08,09-EXT ROOF ,COPING LVL DIAGRAM
Drg Date : 19-09-2025
South building 1.0 240.19 0.49 117.69
South building 1.0 22.07 0.49 10.82
South building 1.0 20.64 0.49 10.11
South building 1.0 17.64 0.49 8.65
South building 1.0 7.73 0.49 3.79
South building 1.0 62.34 0.49 30.55
9.4 2 SIDE STONE CLADDING
Drg Title : 2025-09-18_GVM_A12-08,09-EXT ROOF ,COPING LVL DIAGRAM
Drg Date : 19-09-2025
South building 2.0 20.40 1.13 46.02
9.3 EXTENDED CLADDING
Drg Title : 2025-09-18_GVM_A12-08,09-EXT ROOF ,COPING LVL DIAGRAM
Drg Date : 19-09-2025
South building 1.0 4.80 1.13 5.41
South building 1.0 44.65 1.13 50.37
9.5 S.S CLADDING
Drg Title : 2025-09-18_GVM_A12-08,09-EXT ROOF ,COPING LVL DIAGRAM
Drg Date : 19-09-2025
South building 1.0 86.53 0.35 30.28
South building 1.0 10.20 0.35 3.57
10 FLASHING TYPE
10.1 FLASHING TYPE 1 CODE-A11-01 & 5/A11-01
Flashing Width =.350
Drg Title : 2025-09-18_GVM_A12-08,09-EXT ROOF ,COPING LVL DIAGRAM
Drg Date : 19-09-2025
South building 1.0 24.73 24.73
South building 1.0 6.49 6.49
Drg Title : 2025-09-18_GVM_A12-08,09-EXT ROOF ,COPING LVL DIAGRAM
Drg Date : 19-09-2025
South building 1.0 22.63 22.63
South building 1.0 8.60 8.60
South building 2.0 8.30 16.60
10.2 FLASHING TYPE 2 CODE-A11-01 & 6/A11-01
Drg Title : 2025-09-18_GVM_A12-08,09-EXT ROOF ,COPING LVL DIAGRAM
Drg Date : 19-09-2025
South building 1.0 5.74 5.74
South building 1.0 44.60 44.60
South building 1.0 8.93 8.93
10.1 FLASHING TYPE 3 CODE-A11-01 & 7/A11-01
Drg Title : 2025-09-18_GVM_A12-08,09-EXT ROOF ,COPING LVL DIAGRAM
Drg Date : 19-09-2025
South building 1.0 80.40 80.40
South building 1.0 45.55 45.55
South building 1.0 23.44 23.44
South building 1.0 107.04 107.04
South building 1.0 112.11 112.11
South building 1.0 3.80 3.80
10.1 FLASHING TYPE 4 CODE-A11-01 & 7A/A11-01
Drg Title : 2025-09-18_GVM_A12-08,09-EXT ROOF ,COPING LVL DIAGRAM
Drg Date : 19-09-2025
South building 1.0 84.65 84.65
11 ROOF LEVEL FINISH
11.1 LOOSE GRAVEL STONE CODE-A12-09 & 15/A14-01
Drg Title : 2025-09-18_GVM_A12-08,09-EXT ROOF ,COPING LVL DIAGRAM
Drg Date : 19-09-2025
South block roof 1.0 454.94 454.94
On windows 1.0 8.30 8.30
11.2 GREEN ROOF CODE-A12-09 & 15/A14-01
Drg Title : 2025-09-18_GVM_A12-08,09-EXT ROOF ,COPING LVL DIAGRAM
Drg Date : 19-09-2025
Green roof 1.0 90.97 90.97
11.3 WOODEN DECKING CODE-A12-09 & 15/A14-01
Drg Title : 2025-09-18_GVM_A12-08,09-EXT ROOF ,COPING LVL DIAGRAM
Drg Date : 19-09-2025
VIP terrace 1.0 99.10 99.10
11.4 ZINC ROOFING CODE-A12-09 & 15/A14-01
Drg Title : 2025-09-18_GVM_A12-08,09-EXT ROOF ,COPING LVL DIAGRAM
Drg Date : 19-09-2025
Exit bridge roof 1.0 196.21 196.21
11.5 KOTA STONE CODE-A12-09 & 4/A14-01
Drg Title : 2025-09-18_GVM_A12-08,09-EXT ROOF ,COPING LVL DIAGRAM
Drg Date : 19-09-2025
12 DRAINAGE WALL FINISH (A12-11)
12.1 STONE WALL-LAWN DRAIN CODE-A12-11 & 1/A11-02
Drg Title : 2025-09-18_GVM_A12-11-DRAINAGE DIAGRAM
Drg Date : 19-09-2025
EXIT PASSAGE 1.0 23.07 23.07
Drg Title : 2025-09-18_GVM_A12-11-DRAINAGE DIAGRAM
Drg Date : 19-09-2025
EXIT PASSAGE 1.0 27.03 27.03
12.2 STONE WALL-STONE FLOOR DRAIN CODE-A12-11 & 2/A11-02
LOWER GROUND FLOOR
Drg Title : 2025-09-18_GVM_A12-11-DRAINAGE DIAGRAM
Drg Date : 19-09-2025
Outuer wall of south passage 1.0 5.43 5.43
Drg Title : 2025-09-18_GVM_A12-11-DRAINAGE DIAGRAM
Drg Date : 19-09-2025
Temporary gallery 1.0 18.50 18.50
exit passage 1.0 27.01 27.01
12.3 ALUM. GLAZING - STONE FLOOR DRAIN CODE-A12-11 & 3/A11-02
LOWER GROUND FLOOR
Drg Title : 2025-09-18_GVM_A12-11-DRAINAGE DIAGRAM
Drg Date : 19-09-2025
intro to siddhi gallery 1.0 40.02 40.02
Drg Title : 2025-09-18_GVM_A12-11-DRAINAGE DIAGRAM
Drg Date : 19-09-2025
Exit passage 2.0 1.80 3.60
12.5 STONE FLOOR - STONE FLOOR DRAIN CODE-A12-11 & 5/A11-02
LOWER GROUND FLOOR
Drg Title : 2025-09-18_GVM_A12-11-DRAINAGE DIAGRAM
Drg Date : 19-09-2025
At service entry 1.0 1.80 1.80
12.7 STONE WALL - ROAD DRAIN CODE-A12-11 & 7/A11-02
Drg Title : 2025-09-18_GVM_A12-11-DRAINAGE DIAGRAM
Drg Date : 19-09-2025
Temporary gallery 1.0 76.96 76.96
15.3 WALL MOUNTED S.S RAIL CODE-A12-12 & 01/A7-22
Drg Title : 2025-09-18_GVM_A12-12-RAILING DIAGRAM
Drg Date : 19-09-2025
On Mid-landing 1.0 6.25 6.25
On Mid-landing 1.0 7.46 7.46
Lower Ground Floor
(Location : ELIPTICAL )
Drg Title : 2025-09-18_GVM_A12-12-RAILING DIAGRAM
Drg Date : 19-09-2025
Mid landing-01 & 3 2.0 2.29 4.57
Mid landing-02 1.0 1.99 1.99
Floor Landing-01 (-9900 mm) 1.0 14.46 P-line 14.46
Floor Landing-02 (-8100 mm) 1.0 4.14 P-line 4.14
Mid-landing-3 (-6450 mm) 1.0 8.75 P-line 8.75
Mid-landing-4 (-4650 mm ) 1.0 8.75 P-line 8.75
(Location : ELIPTICAL )
Drg Title : 2025-09-18_GVM_A12-12-RAILING DIAGRAM
Drg Date : 19-09-2025
Floor Landing-05 (-3000mm) 1.0 10.98 P-line 10.98
Mid-landing-6 (-1350mm) 1.0 8.75 P-line 8.75
Mid-landing-7 (+450mm) 1.0 8.75 P-line 8.75
Mid-landing-8 (+2100mm) 1.0 8.75 P-line 8.75
Floor Landing-(-3000mm) 1.0 10.35 P-line 10.35
Mid-landing-6 (-1200mm) 1.0 8.75 P-line 8.75
Mid-landing-7 (+450mm) 1.0 9.35 P-line 9.35
Mid-landing-8 (+2250mm) 1.0 8.75 P-line 8.75
1st Level Plan As per A7_staricase & ramp details
(Location : Stairacse)
Drg Title : GVM_A4_DETAILED PLAN
Drg Date : 11-09-2025
Floor Landing-09 (3900mm) 1.0 10.98 P-line 10.98
Mid-landing-10 (+5550mm) 1.0 8.75 P-line 8.75
Mid-landing-11 (+7350mm) 1.0 8.75 P-line 8.75
Mid-landing-12 (+9000mm) 1.0 8.75 P-line 8.75
Floor Landing-(+3900mm) 1.0 10.26 P-line 10.26
Mid-landing-10 (+5700mm) 1.0 8.75 P-line 8.75
Mid-landing-11 (+7350mm) 1.0 8.75 P-line 8.75
Mid-landing-12 (+9150mm) 1.0 8.75 P-line 8.75
2nd Level Plan As per A7_staricase & ramp details
(Location : Stairacse)
Drg Title : GVM_A4_DETAILED PLAN
Drg Date : 11-09-2025
Floor Landing-013 (10800mm) 1.0 10.98 P-line 10.98
Mid-landing-14 (+12450mm) 1.0 8.75 P-line 8.75
Mid-landing-15 (+14250mm) 1.0 8.75 P-line 8.75
Floor Landing-(+10800mm) 1.0 13.95 P-line 13.95
Mid-landing-14 (+12450mm) 1.0 9.34 P-line 9.34
Mid-landing-15 (+14250mm) 1.0 8.75 P-line 8.75
3rd Level Plan As per A7_staricase & ramp details
(Location : Stairacse)
Drg Title : GVM_A4_DETAILED PLAN
Drg Date : 11-09-2025
Floor Landing-016 (15900mm) 1.0 10.98 P-line 10.98
Mid-landing-17 (+17550mm) 1.0 8.75 P-line 8.75
Mid-landing-18 (+19350mm) 1.0 8.75 P-line 8.75
Floor Landing-(+15900mm) 1.0 9.75 P-line 9.75
Mid-landing-17 (+17550mm) 1.0 10.84 P-line 10.84
Mid-landing-18 (+19350mm) 1.0 8.75 P-line 8.75
Floor Landing-(+20400mm) 1.0 18.88 P-line 18.88
15.4 WALL MOUNTED WOODEN RAIL CODE-A12-12 & 02/A7-22
(Location : ELIPTICAL )
Drg Title : 2025-09-18_GVM_A12-12-RAILING DIAGRAM
Drg Date : 19-09-2025
Fire exit 1.0 4.52 4.52
15.5 GLASS WITH WOODEN RAIL CODE-A12-12 & 09/A7-22
(Location : ELIPTICAL )
Drg Title : 2025-09-18_GVM_A12-12-RAILING DIAGRAM
Drg Date : 19-09-2025
Railing 2.0 9.99 19.99
Railing 1.0 6.45 6.45
Railing 1.0 1.20 1.20
(Location : ELIPTICAL )
Drg Title : 2025-09-18_GVM_A12-12-RAILING DIAGRAM
Drg Date : 19-09-2025
Railing 1.0 5.43 5.43
Railing 1.0 6.45 6.45
Railing 1.0 3.40 3.40
(Location : ELIPTICAL )
Drg Title : 2025-09-18_GVM_A12-12-RAILING DIAGRAM
Drg Date : 19-09-2025
Railing 1.0 7.50 7.50
Railing 1.0 7.43 7.43
15.7 G.I RAILING CODE-A12-12 & 07/A7-22
(Location : ELIPTICAL )
Drg Title : 2025-09-18_GVM_A12-12-RAILING DIAGRAM
Drg Date : 19-09-2025
(Location : ELIPTICAL )
Drg Title : 2025-09-18_GVM_A12-12-RAILING DIAGRAM
Drg Date : 19-09-2025
Service Passage 1.0 6.00 6.00
(Location : ELIPTICAL )
Drg Title : 2025-09-18_GVM_A12-12-RAILING DIAGRAM
Drg Date : 19-09-2025
Service Passage 1.0 8.24 8.24
14 COPING FINISH
9.1 COPING 1 CODE-A11-01 & 4/A11-01
Drg Title : 2025-09-18_GVM_A12-08,09-EXT ROOF ,COPING LVL DIAGRAM
Drg Date : 19-09-2025
South building 2.0 14.75 0.39 11.50
9.2 COPING 2 CODE-A11-01 & 1/A11-01
LOWER GROUND FLOOR
Drg Title : 2025-09-18_GVM_A12-08,09-EXT ROOF ,COPING LVL DIAGRAM
Drg Date : 19-09-2025
South building 1.0 86.04 0.49 42.16
Drg Title : 2025-09-18_GVM_A12-08,09-EXT ROOF ,COPING LVL DIAGRAM
Drg Date : 19-09-2025
South building 1.0 27.03 0.49 13.24
South building 1.0 13.12 0.49 6.43
Drg Title : 2025-09-18_GVM_A12-08,09-EXT ROOF ,COPING LVL DIAGRAM
Drg Date : 19-09-2025
South building 1.0 240.19 0.49 117.69
South building 1.0 22.07 0.49 10.82
South building 1.0 20.64 0.49 10.11
South building 1.0 17.64 0.49 8.65
South building 1.0 7.73 0.49 3.79
South building 1.0 62.34 0.49 30.55
9.4 COPING 4 CODE-A11-01 & 3/A11-01
Drg Title : 2025-09-18_GVM_A12-08,09-EXT ROOF ,COPING LVL DIAGRAM
Drg Date : 19-09-2025
South building 2.0 20.40 0.60 24.48
9.3 COPING 3 CODE-A11-01 & 2/A11-01
Drg Title : 2025-09-18_GVM_A12-08,09-EXT ROOF ,COPING LVL DIAGRAM
Drg Date : 19-09-2025
South building 1.0 4.80 0.60 2.88
South building 1.0 44.65 0.60 26.79
15.1 GUARD RAIL CODE-A12-12 & 03/A7-22
Lower Ground Level Plan
(Location : Stairacse)
Drg Title : GVM_A4_DETAILED PLAN
Drg Date : 11-09-2025
Ground Level Plan
(Location : Stairacse)
Drg Title : GVM_A4_DETAILED PLAN
Drg Date : 11-09-2025
south passage 3.0 1.35 4.05
Entrance stair 11.0 1.85 20.35
First Level Plan
(Location : Stairacse)
Drg Title : GVM_A4_DETAILED PLAN
Drg Date : 11-09-2025
south passage 2.0 1.50 3.00
south passage 4.0 1.73 6.92
south passage 3.0 1.35 4.05
Entrance stair 11.0 1.85 20.35
15.3 WALL MOUNTED S.S RAIL CODE-A12-12 & 01/A7-22
Lower Ground Level Plan
(Location : Stairacse)
Drg Title : GVM_A4_DETAILED PLAN
Drg Date : 11-09-2025
Ground Level Plan As per A7_staricase & ramp details
(Location : Stairacse)
Drg Title : GVM_A4_DETAILED PLAN
Drg Date : 11-09-2025
1st Level Plan As per A7_staricase & ramp details
(Location : Stairacse)
Drg Title : GVM_A4_DETAILED PLAN
Drg Date : 11-09-2025
15.5 GLASS WITH WOODEN RAIL CODE-A12-12 & 09/A7-22
Ground Level Plan As per A7_staricase & ramp details
(Location : Stairacse)
Drg Title : GVM_A4_DETAILED PLAN
Drg Date : 11-09-2025
SOUTH PASSAGE 1.0 1.80 1.80
First Level Plan As per A7_staricase & ramp details
(Location : Stairacse)
Drg Title : GVM_A4_DETAILED PLAN
Drg Date : 11-09-2025
15.6 GLASS WITH WOODEN TOP RAIL CODE-A12-12 & 09/A7-22
Ground Level Plan As per A7_staricase & ramp details
(Location : Stairacse)
Drg Title : GVM_A4_DETAILED PLAN
Drg Date : 11-09-2025
SOUTH PASSAGE 1.0 18.45 18.45
First Level Plan As per A7_staricase & ramp details
(Location : Stairacse)
Drg Title : GVM_A4_DETAILED PLAN
Drg Date : 11-09-2025
SOUTH PASSAGE 1.0 20.70 20.70
9.2 EXPANSION JOINT-EXTERIOR CODE-A12-13 & A11-03
2 ROOF TYPE - 1 (1-A11-03)
Drg Title : 2025-09-18_GVM_A12-08,09-EXT ROOF ,COPING LVL DIAGRAM
Drg No : A12-13
Drg Date : 19-09-2025
2 ROOF TYPE - 2 (2-A11-03)
Drg Title : 2025-09-18_GVM_A12-08,09-EXT ROOF ,COPING LVL DIAGRAM
Drg No : A12-13
Drg Date : 19-09-2025
Drg Title : 2025-09-18_GVM_A12-08,09-EXT ROOF ,COPING LVL DIAGRAM
Drg No : A12-13
Drg Date : 19-09-2025
3 ROOF TYPE - 3 (A11-03)
Drg Title : 2025-09-18_GVM_A12-08,09-EXT ROOF ,COPING LVL DIAGRAM
Drg No : A12-13
Drg Date : 19-09-2025
Drg Title : 2025-09-18_GVM_A12-08,09-EXT ROOF ,COPING LVL DIAGRAM
Drg No : A12-13
Drg Date : 19-09-2025
4 WALL TYPE - 1 (4-A11-03)
Drg Title : 2025-09-18_GVM_A12-08,09-EXT ROOF ,COPING LVL DIAGRAM
Drg No : A12-13
Drg Date : 19-09-2025
Drg Title : 2025-09-18_GVM_A12-08,09-EXT ROOF ,COPING LVL DIAGRAM
Drg No : A12-13
Drg Date : 19-09-2025
LOWER GROUD FLOOR
Drg Title : 2025-09-18_GVM_A12-08,09-EXT ROOF ,COPING LVL DIAGRAM
Drg No : A12-13
Drg Date : 19-09-2025
Drg Title : 2025-09-18_GVM_A12-08,09-EXT ROOF ,COPING LVL DIAGRAM
Drg No : A12-13
Drg Date : 19-09-2025
Drg Title : 2025-09-18_GVM_A12-08,09-EXT ROOF ,COPING LVL DIAGRAM
Drg No : A12-13
Drg Date : 19-09-2025
9.2 EXPANSION JOINT-INTERIOR CODE-A12-13 & A11-03
LOWER GROUD FLOOR
Drg Title : 2025-09-18_GVM_A12-08,09-EXT ROOF ,COPING LVL DIAGRAM
Drg No : A12-13
Drg Date : 19-09-2025
Drg Title : 2025-09-18_GVM_A12-08,09-EXT ROOF ,COPING LVL DIAGRAM
Drg No : A12-13
Drg Date : 19-09-2025
Drg Title : 2025-09-18_GVM_A12-08,09-EXT ROOF ,COPING LVL DIAGRAM
Drg No : A12-13
Drg Date : 19-09-2025
2 FLOORING TYPE-1 (1-A14-11)
Drg Title : 2025-09-18_GVM_A12-08,09-EXT ROOF ,COPING LVL DIAGRAM
Drg No : A12-13
Drg Date : 19-09-2025
Drg Title : 2025-09-18_GVM_A12-08,09-EXT ROOF ,COPING LVL DIAGRAM
Drg No : A12-13
Drg Date : 19-09-2025
3 FLOORING TYPE-2 (2-A14-11)
Drg Title : 2025-09-18_GVM_A12-08,09-EXT ROOF ,COPING LVL DIAGRAM
Drg No : A12-13
Drg Date : 19-09-2025
4 FLOORING TYPE-3 (3-A14-11)
Drg Title : 2025-09-18_GVM_A12-08,09-EXT ROOF ,COPING LVL DIAGRAM
Drg No : A12-13
Drg Date : 19-09-2025
Drg Title : 2025-09-18_GVM_A12-08,09-EXT ROOF ,COPING LVL DIAGRAM
Drg No : A12-13
Drg Date : 19-09-2025
5 FLOORING TYPE-4 (4-A14-11)
Drg Title : 2025-09-18_GVM_A12-08,09-EXT ROOF ,COPING LVL DIAGRAM
Drg No : A12-13
Drg Date : 19-09-2025
Drg Title : 2025-09-18_GVM_A12-08,09-EXT ROOF ,COPING LVL DIAGRAM
Drg No : A12-13
Drg Date : 19-09-2025
13 WATERPROOFING BELOW GROUND LEVEL
13.1 1.2 mm HDPE MEMBRANE PRESSURE SENSITIVE ADHESIVE (Below Footing)
Drg Title : A12-14A,B,C- WATERPROOFING DIAGRAM
Drg Date : 01-04-2026
Connecting Bridge Pile Foundation
13.2 1.2MM CROSS LAMINATED SBS MODIFIED MEMBRANE + 8MM THK HDPE PROTECTION BOARD
Drg Title : A12-14A,B,C- WATERPROOFING DIAGRAM
Drg Date : 01-04-2026
Connecting Bridge Pile Foundation
13.3 1.2 mm HDPE MEMBRANE PRESSURE SENSITIVE ADHESIVE (below grade slab)
Drg Title : A12-14A,B,C- WATERPROOFING DIAGRAM
Drg Date : 01-04-2026
BLOCK C 1.0 791.13 P-area 791.13
BLOCK D 1.0 719.87 P-area 719.87
BLOCK F 1.0 819.46 P-area 819.46
BLOCK G 1.0 1454.74 P-area 1454.74
BLOCK E 1.0 1033.69 P-area 1033.69
13.3 1.2 mm HDPE MEMBRANE PRESSURE SENSITIVE ADHESIVE (below grade slab) ON WALL
Drg Title : A12-14A,B,C- WATERPROOFING DIAGRAM
Drg Date : 01-04-2026
SuPr ENGINEERING CONSULTANTS 307, SIDDHARTH UPSCALE, VASNA ROAD VADODARA-390007 TEL- 0265-3149701 SUMMARY
VADODARA PROJECT : GUJARAT VANDANA MUSEUM, GUJARAT
DATE : 05-09-25 ARCHITECT : OPOLIS
PREPARED BY : MD CLIENT : DIRECTORATE OF ARCHEOLOGY AND MUSEUMS, G.O.G
SR. NO. PARTICULAR UNIT QTY. NO. OF FLOORS TOTAL QTY. QTY. WITH CONTIGENCY
R0 DWGS-RECD-07.07.25
2 MASONRY WORK (FLY ASH WALL)
2.1 100MM THICK FLY ASH MASONRY CODE-A13-01 & 1/A13-08
Basement Floor Cum 0.00 1.00 0.00
Lower Ground Floor Cum 0.00 1.00 0.00
Mezzanine Floor Cum 0.00 1.00 0.00
Ground Floor Cum 0.00 1.00 0.00
First Floor Cum 0.00 1.00 0.00
Mezzanine Floor Cum 0.00 1.00 0.00
Second Floor Cum 0.00 1.00 0.00
Third Floor Cum 0.00 1.00 0.00
Fourth Floor Cum 0.00 1.00 0.00
Total Cum 0.00 0.00
2.2 125MM THICK FLY ASH BLOCK MASONRY CODE-A13-01 & 1/A13-08
Basement Floor Cum 0.00 1.00 0.00
Lower Ground Floor Cum 0.00 1.00 0.00
Mezzanine Floor Cum 0.00 1.00 0.00
Ground Floor Cum 0.00 1.00 0.00
First Floor Cum 0.00 1.00 0.00
Mezzanine Floor Cum 0.00 1.00 0.00
Second Floor Cum 0.00 1.00 0.00
Third Floor Cum 0.00 1.00 0.00
Fourth Floor Cum 0.00 1.00 0.00
Total Cum 0.00 0.00
2.3 150MM THICK FLY ASH BLOCK MASONRY CODE-A13-01 & 1/A13-08
Basement Floor Cum 0.00 1.00 0.00
Lower Ground Floor Cum 0.00 1.00 0.00
Mezzanine Floor Cum 0.00 1.00 0.00
Ground Floor Cum 0.00 1.00 0.00
First Floor Cum 0.00 1.00 0.00
Mezzanine Floor Cum 0.00 1.00 0.00
Second Floor Cum 0.00 1.00 0.00
Third Floor Cum 0.38 1.00 0.38
Fourth Floor Cum 9.73 1.00 9.73
Total Cum 10.11 11.00
2.4 200MM THICK FLY ASH BLOCK MASONRY CODE-A13-01 & 1/A13-08
Basement Floor Cum 0.00 1.00 0.00
Lower Ground Floor Cum 0.00 1.00 0.00
Mezzanine Floor Cum 0.00 1.00 0.00
Ground Floor Cum 0.00 1.00 0.00
First Floor Cum 0.00 1.00 0.00
Mezzanine Floor Cum 0.00 1.00 0.00
Second Floor Cum 0.00 1.00 0.00
Third Floor Cum 6.38 1.00 6.38
Fourth Floor Cum 0.00 1.00 0.00
Total Cum 6.38 7.00
2.5 250MM THICK FLY ASH BLOCK MASONRY CODE-A13-01 & 1/A13-08
Basement Floor Cum 0.00 1.00 0.00
Lower Ground Floor Cum 48.49 1.00 48.49
Mezzanine Floor Cum 0.00 1.00 0.00
Ground Floor Cum 35.49 1.00 35.49
First Floor Cum 67.73 1.00 67.73
Mezzanine Floor Cum 0.00 1.00 0.00
Second Floor Cum 18.02 1.00 18.02
Third Floor Cum 32.63 1.00 32.63
Fourth Floor Cum 61.70 1.00 61.70
Total Cum 264.06 278.00
2.6 300MM THICK FLY ASH BLOCK MASONRY CODE-A13-01 & 1/A13-08
Basement Floor Cum 0.00 1.00 0.00
Lower Ground Floor Cum 30.03 1.00 30.03
Mezzanine Floor Cum 0.00 1.00 0.00
Ground Floor Cum 6.11 1.00 6.11
First Floor Cum 14.78 1.00 14.78
Mezzanine Floor Cum 0.00 1.00 0.00
Second Floor Cum 10.46 1.00 10.46
Third Floor Cum 47.12 1.00 47.12
Fourth Floor Cum 6.57 1.00 6.57
Total Cum 115.07 121.00
2.7 350MM THICK FLY ASH BLOCK MASONRY CODE-A13-01 & 1/A13-08
Basement Floor Cum 0.00 1.00 0.00
Lower Ground Floor Cum 7.98 1.00 7.98
Mezzanine Floor Cum 0.00 1.00 0.00
Ground Floor Cum 0.00 1.00 0.00
First Floor Cum 0.00 1.00 0.00
Mezzanine Floor Cum 0.00 1.00 0.00
Second Floor Cum 3.86 1.00 3.86
Third Floor Cum 0.00 1.00 0.00
Fourth Floor Cum 0.41 1.00 0.41
Total Cum 12.25 13.00
2.8 375MM THICK FLY ASH BLOCK MASONRY CODE-A13-01 & 1/A13-08
Basement Floor Cum 0.00 1.00 0.00
Lower Ground Floor Cum 0.00 1.00 0.00
Mezzanine Floor Cum 0.00 1.00 0.00
Ground Floor Cum 0.00 1.00 0.00
First Floor Cum 0.00 1.00 0.00
Mezzanine Floor Cum 0.00 1.00 0.00
Second Floor Cum 0.00 1.00 0.00
Third Floor Cum 0.00 1.00 0.00
Fourth Floor Cum 0.00 1.00 0.00
Total Cum 0.00 0.00
2.9 400MM THICK FLY ASH BLOCK MASONRY CODE-A13-01 & 1/A13-08
Basement Floor Cum 0.00 1.00 0.00
Lower Ground Floor Cum 0.00 1.00 0.00
Mezzanine Floor Cum 0.00 1.00 0.00
Ground Floor Cum 7.13 1.00 7.13
First Floor Cum 0.00 1.00 0.00
Mezzanine Floor Cum 0.00 1.00 0.00
Second Floor Cum 0.00 1.00 0.00
Third Floor Cum 0.00 1.00 0.00
Fourth Floor Cum 0.00 1.00 0.00
Total Cum 7.13 8.00
2.10 500MM THICK FLY BLOCK MASONRY CODE-A13-01 & 1/A13-08
Basement Floor Cum 0.00 1.00 0.00
Lower Ground Floor Cum 0.00 1.00 0.00
Mezzanine Floor Cum 0.00 1.00 0.00
Ground Floor Cum 0.00 1.00 0.00
First Floor Cum 0.00 1.00 0.00
Mezzanine Floor Cum 0.00 1.00 0.00
Second Floor Cum 0.00 1.00 0.00
Third Floor Cum 0.00 1.00 0.00
Fourth Floor Cum 0.00 1.00 0.00
Total Cum 0.00 0.00
Total of FLY ASH Block Cum 415.01 436.00
3 DRY PARTITION
3.1 100 MM THICK DRY PARTITION WITHOUT INSULATION CODE-A13-01 & 2/A13-08
Basement Floor Sqm 0.00 1.00 0.00
Lower Ground Floor Sqm 0.00 1.00 0.00
Mezzanine Floor Sqm 0.00 1.00 0.00
Ground Floor Sqm 0.00 1.00 0.00
First Floor Sqm 0.00 1.00 0.00
Mezzanine Floor Sqm 0.00 1.00 0.00
Second Floor Sqm 0.00 1.00 0.00
Third Floor Sqm 0.00 1.00 0.00
Fourth Floor Sqm 0.00 1.00 0.00
Total Sqm 0.00 0.00
3.2 100 MM THICK DRY PARTITION WITH INSULATION CODE-A13-01 & 3/A13-08
Basement Floor Sqm 0.00 1.00 0.00
Lower Ground Floor Sqm 0.00 1.00 0.00
Mezzanine Floor Sqm 0.00 1.00 0.00
Ground Floor Sqm 0.00 1.00 0.00
First Floor Sqm 0.00 1.00 0.00
Mezzanine Floor Sqm 0.00 1.00 0.00
Second Floor Sqm 0.00 1.00 0.00
Third Floor Sqm 0.00 1.00 0.00
Fourth Floor Sqm 0.00 1.00 0.00
Total Sqm 0.00 0.00
3.3 200 MM THICK DRY PARTITION CODE-A13-01 & 4/A13-08
Basement Floor Sqm 0.00 1.00 0.00
Lower Ground Floor Sqm 0.00 1.00 0.00
Mezzanine Floor Sqm 0.00 1.00 0.00
Ground Floor Sqm 0.00 1.00 0.00
First Floor Sqm 0.00 1.00 0.00
Mezzanine Floor Sqm 0.00 1.00 0.00
Second Floor Sqm 0.00 1.00 0.00
Third Floor Sqm 0.00 1.00 0.00
Fourth Floor Sqm 0.00 1.00 0.00
Total Sqm 0.00 0.00
3.4 300 MM THICK DRY PARTITION (FOR ELIPSE RAMP) CODE-A13-01 & 5/A13-08
Basement Floor Sqm 0.00 1.00 0.00
Lower Ground Floor Sqm 0.00 1.00 0.00
Mezzanine Floor Sqm 0.00 1.00 0.00
Ground Floor Sqm 0.00 1.00 0.00
First Floor Sqm 0.00 1.00 0.00
Mezzanine Floor Sqm 0.00 1.00 0.00
Second Floor Sqm 0.00 1.00 0.00
Third Floor Sqm 0.00 1.00 0.00
Fourth Floor Sqm 0.00 1.00 0.00
Total Sqm 0.00 0.00
4 AAC BLOCK WALL
4.1 150 MM THICK AAC BLOCK MASONRY CODE-01A13-08
Basement Floor Sqm 0.00 1.00 0.00
Lower Ground Floor Sqm 0.00 1.00 0.00
Mezzanine Floor Sqm 0.00 1.00 0.00
Ground Floor Sqm 0.00 1.00 0.00
First Floor Sqm 0.00 1.00 0.00
Mezzanine Floor Sqm 0.00 1.00 0.00
Second Floor Sqm 0.00 1.00 0.00
Third Floor Sqm 0.00 1.00 0.00
Fourth Floor Sqm 0.00 1.00 0.00
Total Sqm 0.00 0.00
4.2 200 MM THICK AAC BLOCK MASONRY CODE-01A13-08
Basement Floor Cum 0.00 1.00 0.00
Lower Ground Floor Cum 1.21 1.00 1.21
Mezzanine Floor Cum 0.00 1.00 0.00
Ground Floor Cum 1.22 1.00 1.22
First Floor Cum 1.22 1.00 1.22
Mezzanine Floor Cum 0.00 1.00 0.00
Second Floor Cum 0.88 1.00 0.88
Third Floor Cum 0.00 1.00 0.00
Fourth Floor Cum 0.00 1.00 0.00
Total Cum 4.53 5.00
4.3 250 MM THICK AAC BLOCK MASONRY CODE-01A13-08
Basement Floor Cum 0.00 1.00 0.00
Lower Ground Floor Cum 13.72 1.00 13.72
Mezzanine Floor Cum 0.00 1.00 0.00
Ground Floor Cum 52.49 1.00 52.49
First Floor Cum 74.42 1.00 74.42
Mezzanine Floor Cum 11.85 1.00 11.85
Second Floor Cum 10.72 1.00 10.72
Third Floor Cum 16.81 1.00 16.81
Fourth Floor Cum 7.82 1.00 7.82
Total Cum 187.82 198.00
4.4 300 MM THICK AAC BLOCK MASONRY CODE-01A13-08
Basement Floor Cum 0.00 1.00 0.00
Lower Ground Floor Cum 30.92 1.00 30.92
Mezzanine Floor Cum 0.00 1.00 0.00
Ground Floor Cum 0.00 1.00 0.00
First Floor Cum 0.00 1.00 0.00
Mezzanine Floor Cum 0.00 1.00 0.00
Second Floor Cum 0.00 1.00 0.00
Third Floor Cum 3.03 1.00 3.03
Fourth Floor Cum 0.00 1.00 0.00
Total Cum 33.95 36.00
4.5 350 MM THICK AAC BLOCK MASONRY CODE-01A13-08
Basement Floor Cum 2.74 1.00 2.74
Lower Ground Floor Cum 72.52 1.00 72.52
Mezzanine Floor Cum 0.00 1.00 0.00
Ground Floor Cum 16.91 1.00 16.91
First Floor Cum 2.96 1.00 2.96
Mezzanine Floor Cum 0.00 1.00 0.00
Second Floor Cum 1.91 1.00 1.91
Third Floor Cum 0.00 1.00 0.00
Fourth Floor Cum 0.00 1.00 0.00
Total Cum 97.04 102.00
Total of Fly ash Block Cum 323.34 340.00
3 INTERNAL PLATSER WORK
Basement Floor Sqm 252.93 1.00 252.93
Lower Ground Floor Sqm 1864.91 1.00 1864.91
Mezzanine Floor Sqm 0.00 1.00 0.00
Ground Floor Sqm 777.74 1.00 777.74
First Floor Sqm 1126.25 1.00 1126.25
Second Floor Sqm 608.39 1.00 608.39
Third Floor Sqm 738.23 1.00 738.23
Fourth Floor Sqm 676.30 1.00 676.30
Total Sqm 6044.75 6347.00
3 TOILET PLASTER
Basement Floor Sqm 0.00 1.00 0.00
Lower Ground Floor Sqm 626.77 1.00 626.77
Mezzanine Floor Sqm 0.00 1.00 0.00
Ground Floor Sqm 460.48 1.00 460.48
First Floor Sqm 782.34 1.00 782.34
Second Floor Sqm 127.16 1.00 127.16
Third Floor Sqm 0.00 1.00 0.00
Fourth Floor Sqm 377.92 1.00 377.92
Total Sqm 2374.67 2494.00
4 INTERNAL PUTTY WORK
Basement Floor Sqm 2506.86 1.00 2506.86
Lower Ground Floor Sqm 2173.41 1.00 2173.41
Mezzanine Floor Sqm 0.00 1.00 0.00
Ground Floor Sqm 2681.52 1.00 2681.52
First Floor Sqm 2159.81 1.00 2159.81
Second Floor Sqm 1321.19 1.00 1321.19
Third Floor Sqm 1671.47 1.00 1671.47
Fourth Floor Sqm 219.53 1.00 219.53
15 EXTERNAL PLASTER Cum 4686.86 1.00 4686.86
Total Cum 4686.86 4922.00
WATERPROOFING COMPOUND
Total Internal Plaster 12467.78
Total External Plaster 0.00
Considering 2% by weight of Cement bags 1122.10 1.00 1122.10
PLOYESTER FIBRE
Total Internal Plaster 12467.78
Total External Plaster 0.00
Total Bags of cement 1122.10
125 gms. of synthetic Polyester triangular fibre for 50 Kgs. Cement 140.26 1.00 140.26
Total Kg 140.26 148.00
13 WATERPROOFING WORK
13.1 LOCATION : TOILET
Basement Floor Sqm 0.00 1.00 0.00
Lower Ground Floor Sqm 219.41 1.00 219.41
Mezzanine Floor Sqm 0.00 1.00 0.00
Ground Floor Sqm 167.57 1.00 167.57
First Floor Sqm 104.71 1.00 104.71
Second Floor Sqm 37.54 1.00 37.54
Third Floor Sqm 0.00 1.00 0.00
Fourth Floor Sqm 130.22 1.00 130.22
Total Sqm 659.44 726.00
13.2 LOCATION : BASEMENT ON FLOOR
Basement Floor Sqm 1.00 0.00
Lower Ground Floor Sqm 1.00 0.00
Mezzanine Floor Sqm 1.00 0.00
Ground Floor Sqm 1.00 0.00
First Floor Sqm 1.00 0.00
Second Floor Sqm 1.00 0.00
Third Floor Sqm 1.00 0.00
Fourth Floor Sqm 1.00 0.00
Total Sqm 0.00 0.00
13.3 LOCATION : BASEMENT ON WALL
Basement Floor Sqm 1.00 0.00
Lower Ground Floor Sqm 1.00 0.00
Mezzanine Floor Sqm 1.00 0.00
Ground Floor Sqm 1.00 0.00
First Floor Sqm 1.00 0.00
Second Floor Sqm 1.00 0.00
Third Floor Sqm 1.00 0.00
Fourth Floor Sqm 1.00 0.00
Total Sqm 0.00 0.00
13.4 LOCATION : TERRACE
Basement Floor Sqm 0.00 1.00 0.00
Lower Ground Floor Sqm 0.00 1.00 0.00
Mezzanine Floor Sqm 0.00 1.00 0.00
Ground Floor Sqm 0.00 1.00 0.00
First Floor Sqm 0.00 1.00 0.00
Second Floor Sqm 0.00 1.00 0.00
Third Floor Sqm 0.00 1.00 0.00
Fourth Floor Sqm 847.58 1.00 847.58
Total Sqm 847.58 933.00
13.5 LOCATION : LIFT PIT (INSIDE)
Basement Floor Sqm 96.90 1.00 96.90
Lower Ground Floor Sqm 87.10 1.00 87.10
Mezzanine Floor Sqm 0.00 1.00 0.00
Ground Floor Sqm 0.00 1.00 0.00
First Floor Sqm 0.00 1.00 0.00
Second Floor Sqm 0.00 1.00 0.00
Third Floor Sqm 0.00 1.00 0.00
Fourth Floor Sqm 0.00 1.00 0.00
Total Sqm 184.00 203.00
13.5 LOCATION : LIFT PIT (OUTSIDE WALL)
Basement Floor Sqm 91.12 1.00 91.12
Lower Ground Floor Sqm 46.65 1.00 46.65
Mezzanine Floor Sqm 0.00 1.00 0.00
Ground Floor Sqm 0.00 1.00 0.00
First Floor Sqm 0.00 1.00 0.00
Second Floor Sqm 0.00 1.00 0.00
Third Floor Sqm 0.00 1.00 0.00
Fourth Floor Sqm 0.00 1.00 0.00
Total Sqm 137.77 152.00
13.5 LOCATION : TANK
Basement Floor Sqm 2271.96 1.00 2271.96
Lower Ground Floor Sqm 40.30 1.00 40.30
Mezzanine Floor Sqm 0.00 1.00 0.00
Ground Floor Sqm 0.00 1.00 0.00
First Floor Sqm 0.00 1.00 0.00
Second Floor Sqm 92.14 1.00 92.14
Third Floor Sqm 0.00 1.00 0.00
Fourth Floor Sqm 0.00 1.00 0.00
OHT Floor Sqm 61.77 1.00 61.77
Total Sqm 2466.16 2713.00
Basement Floor Cum 132.89 1.00 132.89
Lower Ground Floor Cum 33.95 1.00 33.95
Mezzanine Floor Cum 0.00 1.00 0.00
Ground Floor Cum 27.79 1.00 27.79
First Floor Cum 24.43 1.00 24.43
Second Floor Cum 2.53 1.00 2.53
Third Floor Cum 38.74 1.00 38.74
Fourth Floor Cum 49.90 1.00 49.90
Total Cum 310.24 342.00
5 FLOORING WORK
5.1 MANDANA-1 (25MM THICK GRANITE) FLOORING CODE-A12-04 & 1/A14-01
Basement Floor Sqm 0.00 1.00 0.00
Lower Ground Floor Sqm 146.03 1.00 146.03
Mezzanine Floor Sqm 0.00 1.00 0.00
Ground Floor Sqm 75.23 1.00 75.23
First Floor Sqm 629.28 1.00 629.28
Second Floor Sqm 54.53 1.00 54.53
Third Floor Sqm 699.10 1.00 699.10
Fourth Floor Sqm 272.28 1.00 272.28
Total Sqm 1876.45 1971.00
5.2 T.W WOOD PLANKS 20MM (SOLID WOOD FLOOR) CODE-A12-04 & 5/A14-01
Basement Floor Sqm 0.00 1.00 0.00
Lower Ground Floor Sqm 0.00 1.00 0.00
Mezzanine Floor Sqm 0.00 1.00 0.00
Ground Floor Sqm 0.00 1.00 0.00
First Floor Sqm 0.00 1.00 0.00
Second Floor Sqm 0.00 1.00 0.00
Third Floor Sqm 0.00 1.00 0.00
Fourth Floor Sqm 0.00 1.00 0.00
Total Sqm 0.00 0.00
5.3 VDF CONCERETE FLOORING CODE-A12-04 & 2/A14-02
Basement Floor Cum 0.00 1.00 0.00
Lower Ground Floor Cum 1121.09 1.00 1121.09
Mezzanine Floor Cum 0.00 1.00 0.00
Ground Floor Cum 762.18 1.00 762.18
First Floor Cum 628.32 1.00 628.32
Second Floor Cum 563.72 1.00 563.72
Third Floor Cum 0.00 1.00 0.00
Fourth Floor Cum 0.00 1.00 0.00
5.4 25MM THICK SANDSTONE CODE-A12-04 & 1/A14-01
Basement Floor Sqm 0.00 1.00 0.00
Lower Ground Floor Sqm 0.00 1.00 0.00
Mezzanine Floor Sqm 0.00 1.00 0.00
Ground Floor Sqm 0.00 1.00 0.00
First Floor Sqm 0.00 1.00 0.00
Second Floor Sqm 0.00 1.00 0.00
Third Floor Sqm 0.00 1.00 0.00
Fourth Floor Sqm 0.00 1.00 0.00
Total Sqm 0.00 0.00
5.5 25MM THICK STEEL GREY GRANITE FLOORING CODE-A12-04 & 1/A14-01
Basement Floor Sqm 0.00 1.00 0.00
Lower Ground Floor Sqm 76.44 1.00 76.44
Mezzanine Floor Sqm 0.00 1.00 0.00
Ground Floor Sqm 58.10 1.00 58.10
First Floor Sqm 85.05 1.00 85.05
Second Floor Sqm 12.90 1.00 12.90
Third Floor Sqm 0.00 1.00 0.00
Fourth Floor Sqm 63.52 1.00 63.52
Total Sqm 296.01 311.00
5.6 (Wooden Deck) CODE-A12-04 & 12/A14-01
Basement Floor Sqm 0.00 1.00 0.00
Lower Ground Floor Sqm 0.00 1.00 0.00
Mezzanine Floor Sqm 0.00 1.00 0.00
Ground Floor Sqm 0.00 1.00 0.00
First Floor Sqm 0.00 1.00 0.00
Second Floor Sqm 0.00 1.00 0.00
Third Floor Sqm 0.00 1.00 0.00
Fourth Floor Sqm 0.00 1.00 0.00
Total Sqm 0.00 0.00
5.7 MANDANA-2 (25MM THICK GRANITE) FLOORING CODE-A12-04 & 1/A14-01
Basement Floor Sqm 0.00 1.00 0.00
Lower Ground Floor Sqm 0.00 1.00 0.00
Mezzanine Floor Sqm 0.00 1.00 0.00
Ground Floor Sqm 0.00 1.00 0.00
First Floor Sqm 0.00 1.00 0.00
Second Floor Sqm 0.00 1.00 0.00
Third Floor Sqm 0.00 1.00 0.00
Fourth Floor Sqm 124.47 1.00 124.47
Total Sqm 124.47 131.00
5.8 RUBBER TILE FLOORING CODE-A12-04 & 3/A14-01
Basement Floor Sqm 0.00 1.00 0.00
Lower Ground Floor Sqm 5.15 1.00 5.15
Mezzanine Floor Sqm 0.00 1.00 0.00
Ground Floor Sqm 5.15 1.00 5.15
First Floor Sqm 3.24 1.00 3.24
Second Floor Sqm 0.00 1.00 0.00
Third Floor Sqm 0.00 1.00 0.00
Fourth Floor Sqm 0.00 1.00 0.00
Total Sqm 13.53 15.00
5.9 SS WALK OF MATT CODE-A12-04 & 8/A14-01
Basement Floor Sqm 0.00 1.00 0.00
Lower Ground Floor Sqm 4.14 1.00 4.14
Mezzanine Floor Sqm 0.00 1.00 0.00
Ground Floor Sqm 5.02 1.00 5.02
First Floor Sqm 0.00 1.00 0.00
Second Floor Sqm 0.00 1.00 0.00
Third Floor Sqm 3.30 1.00 3.30
Fourth Floor Sqm 4.63 1.00 4.63
Total Sqm 17.09 18.00
6 INTERNAL WALL FINISH WORK
6.1 SANDSTONE CLADDING DRG CODE- A12-05 REF : 6/A14-02
Basement Floor Sqm 0.00 1.00 0.00
Lower Ground Floor Sqm 153.59 1.00 153.59
Mezzanine Floor Sqm 0.00 1.00 0.00
Ground Floor Sqm 220.84 1.00 220.84
First Floor Sqm 178.48 1.00 178.48
Second Floor Sqm 145.43 1.00 145.43
Third Floor Sqm 108.98 1.00 108.98
Fourth Floor Sqm 246.63 1.00 246.63
Total Sqm 1053.95 1107.00
6.4 MANDANA STONE-3 CLADDING DRG CODE- A12-05 REF : 6/A14-02
Basement Floor Sqm 0.00 1.00 0.00
Lower Ground Floor Sqm 122.60 1.00 122.60
Mezzanine Floor Sqm 0.00 1.00 0.00
Ground Floor Sqm 102.18 1.00 102.18
First Floor Sqm 102.18 1.00 102.18
Second Floor Sqm 102.18 1.00 102.18
Third Floor Sqm 93.75 1.00 93.75
Fourth Floor Sqm 0.00 1.00 0.00
Total Sqm 522.90 550.00
6.5 GRANITE CLADDING DRG CODE- A12-05 REF : 6/A14-02
Basement Floor Sqm 33.57 1.00 33.57
Lower Ground Floor Sqm 57.92 1.00 57.92
Mezzanine Floor Sqm 0.00 1.00 0.00
Ground Floor Sqm 21.59 1.00 21.59
First Floor Sqm 21.90 1.00 21.90
Second Floor Sqm 28.66 1.00 28.66
Third Floor Sqm 0.00 1.00 0.00
Fourth Floor Sqm 19.29 1.00 19.29
Total Sqm 182.93 193.00
Basement Floor Nos. 79.57 1.00 79.57
Lower Ground Floor Nos. 1242.05 1.00 1242.05
Mezzanine Floor Nos. 0.00 1.00 0.00
Ground Floor Nos. 1343.27 1.00 1343.27
First Floor Nos. 1174.56 1.00 1174.56
Second Floor Nos. 1058.38 1.00 1058.38
Third Floor Nos. 810.90 1.00 810.90
Fourth Floor Nos. 1032.24 1.00 1032.24
Total Nos. 6740.97 7416.00
6.2 FIRE RATED GYPSUM BOARD + PAINT DRG CODE- A12-05 REF : 17/A14-02
Basement Floor Sqm 0.00 1.00 0.00
Lower Ground Floor Sqm 1269.08 1.00 1269.08
Mezzanine Floor Sqm 0.00 1.00 0.00
Ground Floor Sqm 873.10 1.00 873.10
First Floor Sqm 799.59 1.00 799.59
Second Floor Sqm 799.59 1.00 799.59
Third Floor Sqm 0.00 1.00 0.00
Fourth Floor Sqm 0.00 1.00 0.00
Total Sqm 3741.36 3929.00
6.3 WOODEN PANELING DRG CODE- A12-05 REF : 7/A14-02
Basement Floor Sqm 0.00 1.00 0.00
Lower Ground Floor Sqm 89.68 1.00 89.68
Mezzanine Floor Sqm 0.00 1.00 0.00
Ground Floor Sqm 105.64 1.00 105.64
First Floor Sqm 44.77 1.00 44.77
Second Floor Sqm 35.17 1.00 35.17
Third Floor Sqm 0.00 1.00 0.00
Fourth Floor Sqm 0.00 1.00 0.00
Total Sqm 275.25 290.00
6.6 S.S CLADDING DRG CODE- A12-05 REF : 13/A14-02
Basement Floor Sqm 0.00 1.00 0.00
Lower Ground Floor Sqm 18.42 1.00 18.42
Mezzanine Floor Sqm 0.00 1.00 0.00
Ground Floor Sqm 0.00 1.00 0.00
First Floor Sqm 0.00 1.00 0.00
Second Floor Sqm 0.00 1.00 0.00
Third Floor Sqm 0.00 1.00 0.00
Fourth Floor Sqm 0.00 1.00 0.00
Total Sqm 18.42 20.00
6.7 VITRIFIED TILES CLADDING DRG CODE- A12-05 REF : 8/A14-02
Basement Floor Sqm 0.00 1.00 0.00
Lower Ground Floor Sqm 227.60 1.00 227.60
Mezzanine Floor Sqm 0.00 1.00 0.00
Ground Floor Sqm 200.78 1.00 200.78
First Floor Sqm 379.78 1.00 379.78
Second Floor Sqm 75.34 1.00 75.34
Third Floor Sqm 0.00 1.00 0.00
Fourth Floor Sqm 211.85 1.00 211.85
Total Sqm 1095.35 1151.00
6.8 MIRROR POLISHED GRANITE CLADDING DRG CODE- A12-05 REF : 6/A14-02
Basement Floor Sqm 0.00 1.00 0.00
Lower Ground Floor Sqm 0.00 1.00 0.00
Mezzanine Floor Sqm 0.00 1.00 0.00
Ground Floor Sqm 0.00 1.00 0.00
First Floor Sqm 0.00 1.00 0.00
Second Floor Sqm 0.00 1.00 0.00
Third Floor Sqm 0.00 1.00 0.00
Fourth Floor Sqm 0.00 1.00 0.00
Total Sqm 0.00 0.00
6.9 VENEER CLADDING DRG CODE- A12-05 REF : 16/A14-02
Basement Floor Sqm 0.00 1.00 0.00
Lower Ground Floor Sqm 0.00 1.00 0.00
Mezzanine Floor Sqm 0.00 1.00 0.00
Ground Floor Sqm 0.00 1.00 0.00
First Floor Sqm 0.00 1.00 0.00
Second Floor Sqm 0.00 1.00 0.00
Third Floor Sqm 0.00 1.00 0.00
Fourth Floor Sqm 0.00 1.00 0.00
Total Sqm 0.00 0.00
8 FALSE CEILING WORK
8.1 PUNCHED GYPSUM + ACOUSTIC LINING CODE-A12-07 & 3/A14-04
Basement Floor Sqm 0.00 1.00 0.00
Lower Ground Floor Sqm 0.00 1.00 0.00
Mezzanine Floor Sqm 0.00 1.00 0.00
Ground Floor Sqm 0.00 1.00 0.00
First Floor Sqm 0.00 1.00 0.00
Second Floor Sqm 0.00 1.00 0.00
Third Floor Sqm 0.00 1.00 0.00
Fourth Floor Sqm 0.00 1.00 0.00
Total Sqm 0.00 0.00
8.2 ALUMINUM PANELS CODE-A12-07 & 4/A14-04
Basement Floor Sqm 0.00 1.00 0.00
Lower Ground Floor Sqm 0.00 1.00 0.00
Mezzanine Floor Sqm 0.00 1.00 0.00
Ground Floor Sqm 0.00 1.00 0.00
First Floor Sqm 0.00 1.00 0.00
Second Floor Sqm 0.00 1.00 0.00
Third Floor Sqm 0.00 1.00 0.00
Fourth Floor Sqm 0.00 1.00 0.00
Total Sqm 0.00 0.00
8.3 GYPSUM + ACOUSTIC LINING CODE-A12-07 & 1/A14-04
Basement Floor Sqm 0.00 1.00 0.00
Lower Ground Floor Sqm 45.75 1.00 45.75
Mezzanine Floor Sqm 0.00 1.00 0.00
Ground Floor Sqm 61.24 1.00 61.24
First Floor Sqm 387.58 1.00 387.58
Second Floor Sqm 36.49 1.00 36.49
Third Floor Sqm 474.19 1.00 474.19
Fourth Floor Sqm 27.41 1.00 27.41
Total Sqm 1032.66 1085.00
8.4 (AUDI) GYPSUM + ACOUSTIC CODE-A12-07 & 2A/A14-04
Basement Floor Sqm 0.00 1.00 0.00
Lower Ground Floor Sqm 0.00 1.00 0.00
Mezzanine Floor Sqm 0.00 1.00 0.00
Ground Floor Sqm 0.00 1.00 0.00
First Floor Sqm 0.00 1.00 0.00
Second Floor Sqm 0.00 1.00 0.00
Third Floor Sqm 0.00 1.00 0.00
Fourth Floor Sqm 0.00 1.00 0.00
Total Sqm 0.00 0.00
8.5 WOODEN CEILING CODE-A12-07 & 9/A14-04
Basement Floor Sqm 0.00 1.00 0.00
Lower Ground Floor Sqm 14.97 1.00 14.97
Mezzanine Floor Sqm 0.00 1.00 0.00
Ground Floor Sqm 44.84 1.00 44.84
First Floor Sqm 14.97 1.00 14.97
Second Floor Sqm 14.97 1.00 14.97
Third Floor Sqm 0.00 1.00 0.00
Fourth Floor Sqm 0.00 1.00 0.00
Total Sqm 89.75 95.00
8.6 WOODEN SLATS CODE-A12-07 & 10/A14-04
Basement Floor Sqm 0.00 1.00 0.00
Lower Ground Floor Sqm 0.00 1.00 0.00
Mezzanine Floor Sqm 0.00 1.00 0.00
Ground Floor Sqm 0.00 1.00 0.00
First Floor Sqm 0.00 1.00 0.00
Second Floor Sqm 0.00 1.00 0.00
Third Floor Sqm 0.00 1.00 0.00
Fourth Floor Sqm 0.00 1.00 0.00
Total Sqm 0.00 0.00
8.7 FRP CANOPY CODE-A12-07 & 7/A14-04
Basement Floor Sqm 0.00 1.00 0.00
Lower Ground Floor Sqm 0.00 1.00 0.00
Mezzanine Floor Sqm 0.00 1.00 0.00
Ground Floor Sqm 0.00 1.00 0.00
First Floor Sqm 0.00 1.00 0.00
Second Floor Sqm 0.00 1.00 0.00
Third Floor Sqm 0.00 1.00 0.00
Fourth Floor Sqm 0.00 1.00 0.00
Total Sqm 0.00 0.00
8.8 ALUMINIUM GRILL CODE-A12-07 & 22/A14-04
Basement Floor Sqm 0.00 1.00 0.00
Lower Ground Floor Sqm 0.00 1.00 0.00
Mezzanine Floor Sqm 0.00 1.00 0.00
Ground Floor Sqm 0.00 1.00 0.00
First Floor Sqm 0.00 1.00 0.00
Second Floor Sqm 0.00 1.00 0.00
Third Floor Sqm 0.00 1.00 0.00
Fourth Floor Sqm 0.00 1.00 0.00
Total Sqm 0.00 0.00
5 FLOORING WORK
5.10 25MM THICK KOTA STONE FLOORING CODE-A12-04 & 4/A14-01
Basement Floor Sqm 1081.90 1.00 1081.90
Lower Ground Floor Sqm 317.41 1.00 317.41
Mezzanine Floor Sqm 0.00 1.00 0.00
Ground Floor Sqm 119.69 1.00 119.69
First Floor Sqm 146.82 1.00 146.82
Second Floor Sqm 50.43 1.00 50.43
Third Floor Sqm 199.70 1.00 199.70
Fourth Floor Sqm 142.77 1.00 142.77
Total Sqm 2058.72 2162.00
5.10 SEALED CONCRETE FLOORING CODE-A12-04 & 13/A14-01
Basement Floor Cum 88.46 1.00 88.46
Lower Ground Floor Cum 21.90 1.00 21.90
Mezzanine Floor Cum 0.00 1.00 0.00
Ground Floor Cum 0.00 1.00 0.00
First Floor Cum 0.00 1.00 0.00
Second Floor Cum 0.00 1.00 0.00
Third Floor Cum 0.00 1.00 0.00
Fourth Floor Cum 0.00 1.00 0.00
Total Cum 0.10 11.04 12.00
5.11 GI WALK OF MATT CODE-A12-04 & 8/A14-01
Basement Floor Sqm 0.00 1.00 0.00
Lower Ground Floor Sqm 4.14 1.00 4.14
Mezzanine Floor Sqm 0.00 1.00 0.00
Ground Floor Sqm 0.00 1.00 0.00
First Floor Sqm 0.00 1.00 0.00
Second Floor Sqm 0.00 1.00 0.00
Third Floor Sqm 0.00 1.00 0.00
Fourth Floor Sqm 0.00 1.00 0.00
Total Sqm 4.14 5.00
5.12 GRATING CODE-A12-04 & 6/A14-01
Basement Floor Sqm 0.00 1.00 0.00
Lower Ground Floor Sqm 53.95 1.00 53.95
Mezzanine Floor Sqm 0.00 1.00 0.00
Ground Floor Sqm 5.01 1.00 5.01
First Floor Sqm 0.00 1.00 0.00
Second Floor Sqm 0.00 1.00 0.00
Third Floor Sqm 4.81 1.00 4.81
Fourth Floor Sqm 0.00 1.00 0.00
Total Sqm 63.78 67.00
5.13 8MM THICK WHITE GLAZED TILES CODE-A12-04 & 11/A14-01
Basement Floor Sqm 605.22 1.00 605.22
Lower Ground Floor Sqm 0.00 1.00 0.00
Mezzanine Floor Sqm 0.00 1.00 0.00
Ground Floor Sqm 0.00 1.00 0.00
First Floor Sqm 23.45 1.00 23.45
Second Floor Sqm 0.00 1.00 0.00
Third Floor Sqm 0.00 1.00 0.00
Fourth Floor Sqm 0.00 1.00 0.00
OHT Floor Sqm 26.55 1.00 26.55
Total Sqm 655.22 688.00
5.14 10 MM THICK VITRIFIED TILES FLOORING CODE-A12-04 & 7/A14-01
Basement Floor Sqm 10.55 1.00 10.55
Lower Ground Floor Sqm 0.00 1.00 0.00
Mezzanine Floor Sqm 0.00 1.00 0.00
Ground Floor Sqm 0.00 1.00 0.00
First Floor Sqm 1.73 1.00 1.73
Second Floor Sqm 0.00 1.00 0.00
Third Floor Sqm 0.00 1.00 0.00
Fourth Floor Sqm 6.44 1.00 6.44
Total Sqm 18.72 20.00
5.15 RAISED ANTI-STATIC FLOORING CODE-A12-04 & 9/A14-01
Basement Floor Sqm 0.00 1.00 0.00
Lower Ground Floor Sqm 0.00 1.00 0.00
Mezzanine Floor Sqm 0.00 1.00 0.00
Ground Floor Sqm 0.00 1.00 0.00
First Floor Sqm 0.00 1.00 0.00
Second Floor Sqm 0.00 1.00 0.00
Third Floor Sqm 0.00 1.00 0.00
Fourth Floor Sqm 0.00 1.00 0.00
Total Sqm 0.00 0.00
5.16 CARPET TILE FLOORING CODE-A12-04 & 10/A14-01
Basement Floor Sqm 0.00 1.00 0.00
Lower Ground Floor Sqm 0.00 1.00 0.00
Mezzanine Floor Sqm 0.00 1.00 0.00
Ground Floor Sqm 0.00 1.00 0.00
First Floor Sqm 0.00 1.00 0.00
Second Floor Sqm 0.00 1.00 0.00
Third Floor Sqm 0.00 1.00 0.00
Fourth Floor Sqm 0.00 1.00 0.00
Total Sqm 0.00 0.00
5.17 MARBLE MOZAIC TILES (BELOW 6.15 FLOOR) Sqm 0.00 0.00
5.18 25 MM THICK GRAY GRANITE FLOORING CODE-A12-04 & 1/A14-01
Basement Floor Sqm 0.00 1.00 0.00
Lower Ground Floor Sqm 0.00 1.00 0.00
Mezzanine Floor Sqm 0.00 1.00 0.00
Ground Floor Sqm 0.00 1.00 0.00
First Floor Sqm 0.00 1.00 0.00
Second Floor Sqm 0.00 1.00 0.00
Third Floor Sqm 0.00 1.00 0.00
Fourth Floor Sqm 0.00 1.00 0.00
Total Sqm 0.00 0.00
5.19 GRANITE+STONE DECK FLOORING CODE-A12-04 & 14/A14-01
Basement Floor Sqm 0.00 1.00 0.00
Lower Ground Floor Sqm 0.00 1.00 0.00
Mezzanine Floor Sqm 0.00 1.00 0.00
Ground Floor Sqm 0.00 1.00 0.00
First Floor Sqm 0.00 1.00 0.00
Second Floor Sqm 0.00 1.00 0.00
Third Floor Sqm 0.00 1.00 0.00
Fourth Floor Sqm 0.00 1.00 0.00
Total Sqm 0.00 0.00
5.20 25MM THICK KOTA STONE FLOORING CODE-A12-04 & 4/A14-01 (LOCATION : Staircase)
Basement Floor Sqm 94.24 1.00 94.24
Lower Ground Floor Sqm 188.80 1.00 188.80
Mezzanine Floor (+70.65) Sqm 28.09 1.00 28.09
Ground Floor Sqm 75.30 1.00 75.30
First Floor Sqm 74.70 1.00 74.70
Second Floor Sqm 61.30 1.00 61.30
Third Floor Sqm 77.45 1.00 77.45
Fourth Floor Sqm 6.60 1.00 6.60
Total Sqm 606.48 637.00
5.20 MANDANA-01 STAIRCASE FLOORING CODE-A12-04 & 1/A14-01 (LOCATION : Staircase)
Basement Floor Sqm 0.00 1.00 0.00
Lower Ground Floor Sqm 0.00 1.00 0.00
Mezzanine Floor Sqm 0.00 1.00 0.00
Ground Floor Sqm 0.00 1.00 0.00
First Floor Sqm 0.00 1.00 0.00
Second Floor Sqm 0.00 1.00 0.00
Third Floor Sqm 3.83 1.00 3.83
Fourth Floor Sqm 0.00 1.00 0.00
Total Sqm 3.83 5.00
5.21 25MM THICK KOTA STONE-TREADS CODE-A12-04 & 4/A14-01 (LOCATION : Staircase)
Basement Floor Rmt 157.50 1.00 157.50
Lower Ground Floor Rmt 242.00 1.00 242.00
Mezzanine Floor Rmt 0.00 1.00 0.00
Ground Floor Rmt 168.00 1.00 168.00
First Floor Rmt 168.00 1.00 168.00
Second Floor Rmt 124.00 1.00 124.00
Third Floor Rmt 116.00 1.00 116.00
Fourth Floor Rmt 0.00 1.00 0.00
Total Rmt 975.50 1025.00
5.22 25MM THICK KOTA STONE-RISERS CODE-A12-04 & 4/A14-01 (LOCATION : Staircase)
Basement Floor Rmt 175.73 1.00 175.73
Lower Ground Floor Rmt 334.00 1.00 334.00
Mezzanine Floor Rmt 0.00 1.00 0.00
Ground Floor Rmt 184.00 1.00 184.00
First Floor Rmt 176.00 1.00 176.00
Second Floor Rmt 136.00 1.00 136.00
Third Floor Rmt 128.00 1.00 128.00
Fourth Floor Rmt 0.00 1.00 0.00
Total Rmt 1133.72 1191.00
5.21 MANDANA-01 STAIRCASE-TREADS CODE-A12-04 & 1/A14-01 (LOCATION : Staircase)
Basement Floor Rmt 0.00 1.00 0.00
Lower Ground Floor Rmt 0.00 1.00 0.00
Mezzanine Floor Rmt 0.00 1.00 0.00
Ground Floor Rmt 0.00 1.00 0.00
First Floor Rmt 0.00 1.00 0.00
Second Floor Rmt 0.00 1.00 0.00
Third Floor Rmt 16.50 1.00 16.50
Fourth Floor Rmt 0.00 1.00 0.00
Total Rmt 16.50 18.00
Total Sqm 0.30 4.95 6.00
5.21 MANDANA-01 STAIRCASE-RISERS CODE-A12-04 & 1/A14-01 (LOCATION : Staircase)
Basement Floor Rmt 0.00 1.00 0.00
Lower Ground Floor Rmt 0.00 1.00 0.00
Mezzanine Floor Rmt 0.00 1.00 0.00
Ground Floor Rmt 0.00 1.00 0.00
First Floor Rmt 0.00 1.00 0.00
Second Floor Rmt 0.00 1.00 0.00
Third Floor Rmt 18.00 1.00 18.00
Fourth Floor Rmt 0.00 1.00 0.00
Total Rmt 18.00 19.00
Total Sqm 0.15 2.70 3.00
5.23 25MM THICK KOTA STONE-SKIRTING CODE-A12-04 & 4/A14-01 (LOCATION : Staircase)
Basement Floor Rmt 72.95 1.00 72.95
Lower Ground Floor Rmt 161.19 1.00 161.19
Mezzanine Floor Rmt 0.00 1.00 0.00
Ground Floor Rmt 71.43 1.00 71.43
First Floor Rmt 73.74 1.00 73.74
Second Floor Rmt 57.52 1.00 57.52
Third Floor Rmt 69.69 1.00 69.69
Fourth Floor Rmt 7.20 1.00 7.20
Total Rmt 513.72 540.00
Total Sqm 0.10 51.37 54.00
5.24 25MM THICK KOTA STONE-INCLINED SKIRTING CODE-A12-04 & 4/A14-01 (LOCATION : Staircase)
Basement Floor Rmt 120.63 1.00 120.63
Lower Ground Floor Rmt 42.50 1.00 42.50
Mezzanine Floor Rmt 0.00 1.00 0.00
Ground Floor Rmt 28.73 1.00 28.73
First Floor Rmt 28.73 1.00 28.73
Second Floor Rmt 21.21 1.00 21.21
Third Floor Rmt 19.87 1.00 19.87
Fourth Floor Rmt 0.00 1.00 0.00
Total Rmt 261.68 275.00
Total Sqm 0.10 26.17 28.00
5.23 MANDANA-01 STAIRCASE SKIRTING CODE-A12-04 & 1/A14-01 (LOCATION : Staircase)
Basement Floor Rmt 0.00 1.00 0.00
Lower Ground Floor Rmt 0.00 1.00 0.00
Mezzanine Floor Rmt 0.00 1.00 0.00
Ground Floor Rmt 0.00 1.00 0.00
First Floor Rmt 0.00 1.00 0.00
Second Floor Rmt 0.00 1.00 0.00
Third Floor Rmt 19.87 1.00 19.87
Fourth Floor Rmt 0.00 1.00 0.00
Total Rmt 0.00 0.00
Total Sqm 0.10 0.00 0.00
5.24 MANDANA-01 STAIRCASE INCLINED SKIRTING CODE-A12-04 & 1/A14-01 (LOCATION : Staircase)
Basement Floor Rmt 0.00 1.00 0.00
Lower Ground Floor Rmt 0.00 1.00 0.00
Mezzanine Floor Rmt 0.00 1.00 0.00
Ground Floor Rmt 0.00 1.00 0.00
First Floor Rmt 0.00 1.00 0.00
Second Floor Rmt 0.00 1.00 0.00
Third Floor Rmt 3.76 1.00 3.76
Fourth Floor Rmt 0.00 1.00 0.00
Total Rmt 0.00 0.00
Total Sqm 0.10 0.00 0.00
INTERNAL FINISH WORK (BOH)
6.10 VITRIFIED TILES-2 CLADDING DRG CODE- A12-05 REF : 8/A14-02
Basement Floor Sqm 0.00 1.00 0.00
Lower Ground Floor Sqm 45.09 1.00 45.09
Mezzanine Floor Sqm 0.00 1.00 0.00
Ground Floor Sqm 0.00 1.00 0.00
First Floor Sqm 0.00 1.00 0.00
Second Floor Sqm 0.00 1.00 0.00
Third Floor Sqm 0.00 1.00 0.00
Fourth Floor Sqm 150.29 1.00 150.29
Total Sqm 195.38 206.00
6.11 GYPSUM / PLASTER + PAINT DRG CODE- A12-05 REF : 10/A14-02
Basement Floor Sqm 1363.61 1.00 1363.61
Lower Ground Floor Sqm 919.78 1.00 919.78
Mezzanine Floor Sqm 0.00 1.00 0.00
Ground Floor Sqm 837.50 1.00 837.50
First Floor Sqm 472.38 1.00 472.38
Second Floor Sqm 528.36 1.00 528.36
Third Floor Sqm 339.58 1.00 339.58
Fourth Floor Sqm 770.21 1.00 770.21
Total Sqm 5231.42 5493.00
6.12 GYPSUM PARTITION WALL SYSTEM DRG CODE- A12-05 REF : 9/A14-02
Basement Floor Sqm 0.00 1.00 0.00
Lower Ground Floor Sqm 0.00 1.00 0.00
Mezzanine Floor Sqm 0.00 1.00 0.00
Ground Floor Sqm 0.00 1.00 0.00
First Floor Sqm 0.00 1.00 0.00
Second Floor Sqm 0.00 1.00 0.00
Third Floor Sqm 0.00 1.00 0.00
Fourth Floor Sqm 0.00 1.00 0.00
Total Sqm 0.00 0.00
6.13 SOUND ATTENAUTION DRG CODE- A12-05 REF : 11/A14-02
Basement Floor Sqm 1189.87 1.00 1189.87
Lower Ground Floor Sqm 303.62 1.00 303.62
Mezzanine Floor Sqm 0.00 1.00 0.00
Ground Floor Sqm 120.47 1.00 120.47
First Floor Sqm 277.47 1.00 277.47
Second Floor Sqm 0.00 1.00 0.00
Third Floor Sqm 268.57 1.00 268.57
Fourth Floor Sqm 0.00 1.00 0.00
Total Sqm 2160.00 2269.00
6.14 WHITE GLAZED VITRIFIED TILES CLADDING DRG CODE- A12-05 REF : 8/A14-02
Basement Floor Sqm 1666.74 1.00 1666.74
Lower Ground Floor Sqm 0.00 1.00 0.00
Mezzanine Floor Sqm 0.00 1.00 0.00
Ground Floor Sqm 0.00 1.00 0.00
First Floor Sqm 0.00 1.00 0.00
Second Floor (+70.85 mez lvl) Sqm 68.69 1.00 68.69
Third Floor Sqm 0.00 1.00 0.00
Fourth Floor Sqm 0.00 1.00 0.00
OHT floor Sqm 35.22 1.00 35.22
Total Sqm 1770.65 1860.00
6.15 PLASTER + PAINT DRG CODE- A12-05 REF : 14/A14-02
Basement Floor Sqm 0.00 1.00 0.00
Lower Ground Floor Sqm 0.00 1.00 0.00
Mezzanine Floor Sqm 0.00 1.00 0.00
Ground Floor Sqm 0.00 1.00 0.00
First Floor Sqm 0.00 1.00 0.00
Second Floor Sqm 0.00 1.00 0.00
Third Floor Sqm 0.00 1.00 0.00
Fourth Floor Sqm 0.00 1.00 0.00
Total Sqm 0.00 0.00
6.16 PLASTER FINISH DRG CODE- A12-05 REF : 15/A14-02
Basement Floor Sqm 305.73 1.00 305.73
Lower Ground Floor Sqm 841.94 1.00 841.94
Mezzanine Floor Sqm 0.00 1.00 0.00
Ground Floor Sqm 913.66 1.00 913.66
First Floor Sqm 791.28 1.00 791.28
Second Floor Sqm 588.39 1.00 588.39
Third Floor Sqm 447.02 1.00 447.02
Fourth Floor Sqm 160.35 1.00 160.35
Total Sqm 4048.35 4251.00
6.17 ALUMINIUM CLADDING DRG CODE- A12-05 REF : 12/A14-02
Basement Floor Sqm 0.00 1.00 0.00
Lower Ground Floor Sqm 0.00 1.00 0.00
Mezzanine Floor Sqm 0.00 1.00 0.00
Ground Floor Sqm 0.00 1.00 0.00
First Floor Sqm 0.00 1.00 0.00
Second Floor Sqm 0.00 1.00 0.00
Third Floor Sqm 0.00 1.00 0.00
Fourth Floor Sqm 0.00 1.00 0.00
Total Sqm 0.00 0.00
7 SKIRTING WORK
7.1 WOODEN SKIRTING CODE-A12-06 & 3/A14-03
Basement Floor Rmt 0.00 1.00 0.00
Lower Ground Floor Rmt 0.00 1.00 0.00
Mezzanine Floor Rmt 0.00 1.00 0.00
Ground Floor Rmt 0.00 1.00 0.00
First Floor Rmt 0.00 1.00 0.00
Second Floor Rmt 0.00 1.00 0.00
Third Floor Rmt 0.00 1.00 0.00
Fourth Floor Rmt 0.00 1.00 0.00
Total Rmt 0.00 0.00
7.2 KOTA STONE SKIRTING (LOADING BAY) CODE-A12-06 & 2/A14-03
Basement Floor Rmt 0.00 1.00 0.00
Lower Ground Floor Rmt 0.00 1.00 0.00
Mezzanine Floor Rmt 0.00 1.00 0.00
Ground Floor Rmt 0.00 1.00 0.00
First Floor Rmt 0.00 1.00 0.00
Second Floor Rmt 0.00 1.00 0.00
Third Floor Rmt 0.00 1.00 0.00
Fourth Floor Rmt 0.00 1.00 0.00
Total Rmt 0.00 0.00
Total Sqm 0.10 0.00 0.00
7.3 KOTA STONE SKIRTING CODE-A12-06 & 1/A14-03
Basement Floor Rmt 447.66 1.00 447.66
Lower Ground Floor Rmt 134.15 1.00 134.15
Mezzanine Floor Rmt 0.00 1.00 0.00
Ground Floor Rmt 42.32 1.00 42.32
First Floor Rmt 60.00 1.00 60.00
Second Floor Rmt 16.95 1.00 16.95
Third Floor Rmt 95.46 1.00 95.46
Fourth Floor Rmt 27.03 1.00 27.03
Total Rmt 823.57 865.00
Total Sqm 0.10 82.36 87.00
7.4 S.S BASE (COLUMN) CODE-A12-06 & 4/A14-03
Basement Floor Rmt 0.00 1.00 0.00
Lower Ground Floor Rmt 0.00 1.00 0.00
Mezzanine Floor Rmt 0.00 1.00 0.00
Ground Floor Rmt 10.84 1.00 10.84
First Floor Rmt 0.00 1.00 0.00
Second Floor Rmt 0.00 1.00 0.00
Third Floor Rmt 0.00 1.00 0.00
Fourth Floor Rmt 0.00 1.00 0.00
Total Rmt 10.84 12.00
Total Sqm 0.10 1.08 2.00
8 FALSE CEILING WORK
8.9 MINERAL FIBRE GRID CEILING 600X600 CODE-A12-07 & 2/A14-04
Basement Floor Sqm 0.00 1.00 0.00
Lower Ground Floor Sqm 104.08 1.00 104.08
Mezzanine Floor Sqm 0.00 1.00 0.00
Ground Floor Sqm 37.81 1.00 37.81
First Floor Sqm 38.08 1.00 38.08
Second Floor Sqm 43.42 1.00 43.42
Third Floor Sqm 12.03 1.00 12.03
Fourth Floor Sqm 0.00 1.00 0.00
Total Sqm 235.42 248.00
8.10 GYPSUM + PAINT CODE-A12-07 & 5/A14-04
Basement Floor Sqm 0.00 1.00 0.00
Lower Ground Floor Sqm 76.17 1.00 76.17
Mezzanine Floor Sqm 0.00 1.00 0.00
Ground Floor Sqm 80.16 1.00 80.16
First Floor Sqm 88.63 1.00 88.63
Second Floor Sqm 12.70 1.00 12.70
Third Floor Sqm 0.00 1.00 0.00
Fourth Floor Sqm 62.98 1.00 62.98
Total Sqm 320.64 337.00
8.11 PLASTER FINISH CODE-A12-07
Basement Floor Sqm 0.00 1.00 0.00
Lower Ground Floor Sqm 0.00 1.00 0.00
Mezzanine Floor Sqm 0.00 1.00 0.00
Ground Floor Sqm 0.00 1.00 0.00
First Floor Sqm 0.00 1.00 0.00
Second Floor Sqm 0.00 1.00 0.00
Third Floor Sqm 7.73 1.00 7.73
Fourth Floor Sqm 0.00 1.00 0.00
Total Sqm 7.73 9.00
8.12 METAL CEILING CODE-A12-07 & 11/A14-04
Basement Floor Sqm 0.00 1.00 0.00
Lower Ground Floor Sqm 0.00 1.00 0.00
Mezzanine Floor Sqm 0.00 1.00 0.00
Ground Floor Sqm 0.00 1.00 0.00
First Floor Sqm 0.00 1.00 0.00
Second Floor Sqm 0.00 1.00 0.00
Third Floor Sqm 0.00 1.00 0.00
Fourth Floor Sqm 88.04 1.00 88.04
Total Sqm 88.04 93.00
8.13 PLASTER + PAINT CODE-A12-07 & 5/A14-04
Basement Floor Sqm 583.16 1.00 583.16
Lower Ground Floor Sqm 0.00 1.00 0.00
Mezzanine Floor Sqm 0.00 1.00 0.00
Ground Floor Sqm 0.00 1.00 0.00
First Floor Sqm 0.00 1.00 0.00
Second Floor Sqm 0.00 1.00 0.00
Third Floor Sqm 27.12 1.00 27.12
Fourth Floor Sqm 1.94 1.00 1.94
Total Sqm 612.22 643.00
8.14 SOUND ATTENUATION CODE-A12-07 & 8/A14-04
Basement Floor Sqm 875.52 1.00 875.52
Lower Ground Floor Sqm 62.53 1.00 62.53
Mezzanine Floor Sqm 0.00 1.00 0.00
Ground Floor Sqm 55.32 1.00 55.32
First Floor Sqm 99.90 1.00 99.90
Second Floor Sqm 0.00 1.00 0.00
Third Floor Sqm 129.09 1.00 129.09
Fourth Floor Sqm 0.00 1.00 0.00
Total Sqm 1222.36 1284.00
8.15 M.R GRADE GYPSUM GRID 600X600 CODE-A12-07 & 7/A14-04
Basement Floor Sqm 0.00 1.00 0.00
Lower Ground Floor Sqm 7.85 1.00 7.85
Mezzanine Floor Sqm 0.00 1.00 0.00
Ground Floor Sqm 0.00 1.00 0.00
First Floor Sqm 0.00 1.00 0.00
Second Floor Sqm 0.00 1.00 0.00
Third Floor Sqm 0.00 1.00 0.00
Fourth Floor Sqm 3.90 1.00 3.90
Total Sqm 11.75 13.00
8.16 BARRIOL CEILING CODE-A12-07 & 20/A14-04
Basement Floor Sqm 0.00 1.00 0.00
Lower Ground Floor Sqm 0.00 1.00 0.00
Mezzanine Floor Sqm 0.00 1.00 0.00
Ground Floor Sqm 0.00 1.00 0.00
First Floor Sqm 0.00 1.00 0.00
Second Floor Sqm 0.00 1.00 0.00
Third Floor Sqm 0.00 1.00 0.00
Fourth Floor Sqm 0.00 1.00 0.00
Total Sqm 0.00 0.00
8.17 FOAM FINISH CODE-A12-07 & 6/A14-04
Basement Floor Sqm 0.00 1.00 0.00
Lower Ground Floor Sqm 0.00 1.00 0.00
Mezzanine Floor Sqm 0.00 1.00 0.00
Ground Floor Sqm 0.00 1.00 0.00
First Floor Sqm 0.00 1.00 0.00
Second Floor Sqm 0.00 1.00 0.00
Third Floor Sqm 0.00 1.00 0.00
Fourth Floor Sqm 0.00 1.00 0.00
Total Sqm 0.00 0.00
15.12 GRANITE COUNTER
Basement Floor Sqm 0.00 1.00 0.00
Lower Ground Floor Sqm 4.96 1.00 4.96
Mezzanine Floor Sqm 0.00 1.00 0.00
Ground Floor Sqm 3.06 1.00 3.06
First Floor Sqm 6.05 1.00 6.05
Second Floor Sqm 0.00 1.00 0.00
Third Floor Sqm 0.00 1.00 0.00
Fourth Floor Sqm 2.73 1.00 2.73
Total Sqm 16.80 18.00
15.12 FACIA - GRANITE
Basement Floor Rmt 0.00 1.00 0.00
Lower Ground Floor Rmt 7.81 1.00 7.81
Mezzanine Floor Rmt 0.00 1.00 0.00
Ground Floor Rmt 4.80 1.00 4.80
First Floor Rmt 9.30 1.00 9.30
Second Floor Rmt 0.00 1.00 0.00
Third Floor Rmt 0.00 1.00 0.00
Fourth Floor Rmt 4.20 1.00 4.20
Total Rmt 26.11 28.00
15.12 SINK NUMBER
Basement Floor Nos 0.00 1.00 0.00
Lower Ground Floor Nos 8.00 1.00 8.00
Mezzanine Floor Nos 0.00 1.00 0.00
Ground Floor Nos 5.00 1.00 5.00
First Floor Nos 8.00 1.00 8.00
Second Floor Nos 0.00 1.00 0.00
Third Floor Nos 0.00 1.00 0.00
Fourth Floor Nos 5.00 1.00 5.00
Total Nos 26.00 26.00
13 WATERPROOFING BELOW GROUND LEVEL
13.1 1.2 mm HDPE MEMBRANE PRESSURE SENSITIVE ADHESIVE (Below Footing)
Basement level 1.0 2162.29 1.00 2162.29
13.2 1.2MM CROSS LAMINATED SBS MODIFIED MEMBRANE + 8MM THK HDPE PROTECTION BOARD
Basement level 1.0 1122.10 1.00 1122.10
13.3 1.2 mm HDPE MEMBRANE PRESSURE SENSITIVE ADHESIVE (below grade slab)
Basement level 1.0 2633.75 1.00 2633.75
13.4 1.2MM CROSS LAMINATED SBS MODIFIED MEMBRANE + 8MM THK HDPE PROTECTION BOARD
Basement level 1.0 440.35 1.00 440.35
11.5 KOTA STONE CODE-A12-09 & 4/A14-01
Basement Floor Sqm 0.00 1.00 0.00
Lower Ground Floor Sqm 0.00 1.00 0.00
Mezzanine Floor Sqm 0.00 1.00 0.00
Ground Floor Sqm 0.00 1.00 0.00
First Floor Sqm 0.00 1.00 0.00
Second Floor Sqm 0.00 1.00 0.00
Third Floor Sqm 0.00 1.00 0.00
Fourth Floor Sqm 0.00 1.00 0.00
Total Sqm 0.00 0.00
15.1 GUARD RAIL CODE-A12-12 & 03/A7-22
Basement Floor Rmt 1.00 0.00
Lower Ground Floor Rmt 1.00 0.00
Mezzanine Floor Rmt 1.00 0.00
Ground Floor Rmt 1.00 0.00
First Floor Rmt 1.00 0.00
Second Floor Rmt 1.00 0.00
Third Floor Rmt 1.00 0.00
Fourth Floor Rmt 1.00 0.00
Total Rmt 0.00 0.00
15.2 DOUBLE HANDLE WOODEN RAIL CODE-A12-12 & 06/A7-22
Basement Floor Rmt 1.00 0.00
Lower Ground Floor Rmt 1.00 0.00
Mezzanine Floor Rmt 1.00 0.00
Ground Floor Rmt 1.00 0.00
First Floor Rmt 1.00 0.00
Second Floor Rmt 1.00 0.00
Third Floor Rmt 1.00 0.00
Fourth Floor Rmt 7.66 1.00 7.66
Total Rmt 7.66 9.00
15.3 WALL MOUNTED S.S RAIL CODE-A12-12 & 01/A7-22
Basement Floor Rmt 34.25 1.00 34.25
Lower Ground Floor Rmt 95.53 1.00 95.53
Mezzanine Floor Rmt 0.00 1.00 0.00
Ground Floor Rmt 100.16 1.00 100.16
First Floor Rmt 102.47 1.00 102.47
Second Floor Rmt 78.73 1.00 78.73
Third Floor Rmt 89.56 1.00 89.56
Fourth Floor Rmt 0.00 1.00 0.00
Total Rmt 500.71 526.00
15.4 WALL MOUNTED WOODEN RAIL CODE-A12-12 & 02/A7-22
Basement Floor Rmt 1.00 0.00
Lower Ground Floor Rmt 1.00 0.00
Mezzanine Floor Rmt 1.00 0.00
Ground Floor Rmt 4.52 1.00 4.52
First Floor Rmt 1.00 0.00
Second Floor Rmt 1.00 0.00
Third Floor Rmt 58.49 1.00 58.49
Fourth Floor Rmt 110.88 1.00 110.88
Total Rmt 173.89 183.00
15.5 GLASS WITH WOODEN RAIL CODE-A12-12 & 09/A7-22
Basement Floor Rmt 1.00 0.00
Lower Ground Floor Rmt 1.00 0.00
Mezzanine Floor Rmt 1.00 0.00
Ground Floor Rmt 27.64 1.00 27.64
First Floor Rmt 32.67 1.00 32.67
Second Floor Rmt 22.73 1.00 22.73
Third Floor Rmt 1.00 0.00
Fourth Floor Rmt 1.00 0.00
Total Rmt 83.03 88.00
15.6 GLASS WITH WOODEN TOP RAIL CODE-A12-12 & 09/A7-22
Basement Floor Rmt 1.00 0.00
Lower Ground Floor Rmt 1.00 0.00
Mezzanine Floor Rmt 1.00 0.00
Ground Floor Rmt 1.00 0.00
First Floor Rmt 1.00 0.00
Second Floor Rmt 1.00 0.00
Third Floor Rmt 1.00 0.00
Fourth Floor Rmt 1.00 0.00
Total Rmt 0.00 0.00
15.7 G.I RAILING CODE-A12-12 & 07/A7-22
Basement Floor Rmt 20.41 1.00 20.41
Lower Ground Floor Rmt 1.00 0.00
Mezzanine Floor Rmt 1.00 0.00
Ground Floor Rmt 6.00 1.00 6.00
First Floor Rmt 8.24 1.00 8.24
Second Floor Rmt 1.00 0.00
Third Floor Rmt 6.69 1.00 6.69
Fourth Floor Rmt 6.69 1.00 6.69
Total Rmt 48.02 51.00
15.8 WOODEN RAIL CODE-A12-12 & 10/A7-22
Basement Floor Rmt 1.00 0.00
Lower Ground Floor Rmt 1.00 0.00
Mezzanine Floor Rmt 1.00 0.00
Ground Floor Rmt 1.00 0.00
First Floor Rmt 216.30 1.00 216.30
Second Floor Rmt 216.30 1.00 216.30
Third Floor Rmt 1.00 0.00
Fourth Floor Rmt 1.00 0.00
Total Rmt 432.60 455.00
15.9 GLASS WITH SS CAP CODE-A12-12 & 08/A7-22
Basement Floor Rmt 1.00 0.00
Lower Ground Floor Rmt 1.00 0.00
Mezzanine Floor Rmt 1.00 0.00
Ground Floor Rmt 1.00 0.00
First Floor Rmt 1.00 0.00
Second Floor Rmt 1.00 0.00
Third Floor Rmt 1.00 0.00
Fourth Floor Rmt 35.66 1.00 35.66
Total Rmt 35.66 38.00
Basement Floor Nos 0.00 1.00 0.00
Lower Ground Floor Nos 8.00 1.00 8.00
Mezzanine Floor Nos 0.00 1.00 0.00
Ground Floor Nos 6.00 1.00 6.00
First Floor Nos 4.00 1.00 4.00
Second Floor Nos 1.00 1.00 1.00
Third Floor Nos 0.00 1.00 0.00
Fourth Floor Nos 4.00 1.00 4.00
Total Nos 23.00 23.00
Basement Floor Nos 0.00 1.00 0.00
Lower Ground Floor Nos 2.00 1.00 2.00
Mezzanine Floor Nos 0.00 1.00 0.00
Ground Floor Nos 2.00 1.00 2.00
First Floor Nos 2.00 1.00 2.00
Second Floor Nos 1.00 1.00 1.00
Third Floor Nos 0.00 1.00 0.00
Fourth Floor Nos 2.00 1.00 2.00
Total Nos 9.00 9.00
2 URINAL PARTITION
Basement Floor Sqm 0.00 1.00 0.00
Lower Ground Floor Sqm 1.50 1.00 1.50
Mezzanine Floor Sqm 0.00 1.00 0.00
Ground Floor Sqm 1.20 1.00 1.20
First Floor Sqm 0.90 1.00 0.90
Second Floor Sqm 0.00 1.00 0.00
Third Floor Sqm 0.00 1.00 0.00
Fourth Floor Sqm 0.00 1.00 0.00
Total Sqm 3.60 4.00
9 PARAPET FINISH
9.1 2 SIDE PLASTER CODE-A12-08 & 4/A11-01
Basement Floor Sqm 0.00 1.00 0.00
Lower Ground Floor Sqm 0.00 1.00 0.00
Mezzanine Floor Sqm 0.00 1.00 0.00
Ground Floor Sqm 0.00 1.00 0.00
First Floor Sqm 0.00 1.00 0.00
Second Floor Sqm 0.00 1.00 0.00
Third Floor Sqm 0.00 1.00 0.00
Fourth Floor Sqm 0.00 1.00 0.00
Roof Floor Sqm 168.17 1.00 168.17
Total Sqm 168.17 177.00
9.2 1SIDE STONE CLADDING CODE-A12-08 & 1/A11-01
Basement Floor Sqm 0.00 1.00 0.00
Lower Ground Floor Sqm 74.38 1.00 74.38
Mezzanine Floor Sqm 0.00 1.00 0.00
Ground Floor Sqm 0.00 1.00 0.00
First Floor Sqm 0.00 1.00 0.00
Second Floor Sqm 0.00 1.00 0.00
Third Floor Sqm 0.00 1.00 0.00
Fourth Floor Sqm 0.00 1.00 0.00
Roof Floor Sqm 97.49 1.00 97.49
Total Sqm 171.87 181.00
9.3 EXTENDED CLADDING CODE-A12-08 & 2/A11-01
Basement Floor Sqm 0.00 1.00 0.00
Lower Ground Floor Sqm 0.00 1.00 0.00
Mezzanine Floor Sqm 0.00 1.00 0.00
Ground Floor Sqm 0.00 1.00 0.00
First Floor Sqm 0.00 1.00 0.00
Second Floor Sqm 0.00 1.00 0.00
Third Floor Sqm 0.00 1.00 0.00
Fourth Floor Sqm 0.00 1.00 0.00
Total Sqm 0.00 0.00
9.4 2 SIDE STONE CLADDING CODE-A12-08 & 3/A11-01
Basement Floor Sqm 0.00 1.00 0.00
Lower Ground Floor Sqm 0.00 1.00 0.00
Mezzanine Floor Sqm 0.00 1.00 0.00
Ground Floor Sqm 0.00 1.00 0.00
First Floor Sqm 0.00 1.00 0.00
Second Floor Sqm 0.00 1.00 0.00
Third Floor Sqm 0.00 1.00 0.00
Fourth Floor Sqm 460.27 1.00 460.27
Total Sqm 460.27 484.00
9.5 S.S CLADDING CODE-A12-08 & 5/A11-01
Basement Floor Sqm 0.00 1.00 0.00
Lower Ground Floor Sqm 0.00 1.00 0.00
Mezzanine Floor Sqm 0.00 1.00 0.00
Ground Floor Sqm 0.00 1.00 0.00
First Floor Sqm 0.00 1.00 0.00
Second Floor Sqm 0.00 1.00 0.00
Third Floor Sqm 0.00 1.00 0.00
Fourth Floor Sqm 0.00 1.00 0.00
Total Sqm 0.00 0.00
9.6 WET CLADDING CODE-A12-08 & 6/A11-01
Basement Floor Sqm 0.00 1.00 0.00
Lower Ground Floor Sqm 0.00 1.00 0.00
Mezzanine Floor Sqm 0.00 1.00 0.00
Ground Floor Sqm 0.00 1.00 0.00
First Floor Sqm 0.00 1.00 0.00
Second Floor Sqm 0.00 1.00 0.00
Third Floor Sqm 0.00 1.00 0.00
Fourth Floor Sqm 0.00 1.00 0.00
Total Sqm 0.00 0.00
10 FLASHING TYPE
10.1 FLASHING TYPE 1 CODE-A12-08 & 5/A11-01
Basement Floor Sqm 0.00 1.00 0.00
Lower Ground Floor Sqm 0.00 1.00 0.00
Mezzanine Floor Sqm 0.00 1.00 0.00
Ground Floor Sqm 0.00 1.00 0.00
First Floor Sqm 19.72 1.00 19.72
Second Floor Sqm 0.00 1.00 0.00
Third Floor Sqm 0.00 1.00 0.00
Fourth Floor Sqm 0.00 1.00 0.00
Total Sqm 19.72 21.00
10.2 FLASHING TYPE 2 CODE-A12-08 & 6/A11-01
Basement Floor Sqm 0.00 1.00 0.00
Lower Ground Floor Sqm 0.00 1.00 0.00
Mezzanine Floor Sqm 0.00 1.00 0.00
Ground Floor Sqm 0.00 1.00 0.00
First Floor Sqm 0.00 1.00 0.00
Second Floor Sqm 0.00 1.00 0.00
Third Floor Sqm 0.00 1.00 0.00
Fourth Floor Sqm 0.00 1.00 0.00
Total Sqm 0.00 0.00
10.3 FLASHING TYPE 3 CODE-A12-08 & 7/A11-01
Basement Floor Sqm 0.00 1.00 0.00
Lower Ground Floor Sqm 0.00 1.00 0.00
Mezzanine Floor Sqm 0.00 1.00 0.00
Ground Floor Sqm 0.00 1.00 0.00
First Floor Sqm 0.00 1.00 0.00
Second Floor Sqm 0.00 1.00 0.00
Third Floor Sqm 0.00 1.00 0.00
Fourth Floor Sqm 0.00 1.00 0.00
Roof Floor Sqm 124.64 1.00 124.64
Total Sqm 124.64 131.00
10.4 FLASHING TYPE 4 CODE-A12-08 & 7A/A11-01
Basement Floor Sqm 0.00 1.00 0.00
Lower Ground Floor Sqm 0.00 1.00 0.00
Mezzanine Floor Sqm 0.00 1.00 0.00
Ground Floor Sqm 0.00 1.00 0.00
First Floor Sqm 0.00 1.00 0.00
Second Floor Sqm 0.00 1.00 0.00
Third Floor Sqm 0.00 1.00 0.00
Fourth Floor Sqm 0.00 1.00 0.00
Total Sqm 0.00 0.00
11 ROOF LEVEL FINISH
11.1 LOOSE GRAVEL STONE CODE-A12-09 & 15/A14-01
Basement Floor Sqm 0.00 1.00 0.00
Lower Ground Floor Sqm 0.00 1.00 0.00
Mezzanine Floor Sqm 0.00 1.00 0.00
Ground Floor Sqm 0.00 1.00 0.00
First Floor Sqm 0.00 1.00 0.00
Second Floor Sqm 0.00 1.00 0.00
Third Floor Sqm 0.00 1.00 0.00
Fourth Floor Sqm 0.00 1.00 0.00
Terrace Floor Sqm 386.54 1.00 386.54
Roof Floor Sqm 21.08 1.00 21.08
Total Sqm 407.62 429.00
11.2 GREEN ROOF CODE-A12-09 & 15/A14-01
Basement Floor Sqm 0.00 1.00 0.00
Lower Ground Floor Sqm 0.00 1.00 0.00
Mezzanine Floor Sqm 0.00 1.00 0.00
Ground Floor Sqm 0.00 1.00 0.00
First Floor Sqm 0.00 1.00 0.00
Second Floor Sqm 0.00 1.00 0.00
Third Floor Sqm 0.00 1.00 0.00
Fourth Floor Sqm 96.24 1.00 96.24
Total Sqm 96.24 102.00
11.3 WOODEN DECKING CODE-A12-09 & 15/A14-01
Basement Floor Sqm 0.00 1.00 0.00
Lower Ground Floor Sqm 0.00 1.00 0.00
Mezzanine Floor Sqm 0.00 1.00 0.00
Ground Floor Sqm 0.00 1.00 0.00
First Floor Sqm 0.00 1.00 0.00
Second Floor Sqm 0.00 1.00 0.00
Third Floor Sqm 0.00 1.00 0.00
Fourth Floor Sqm 0.00 1.00 0.00
Total Sqm 0.00 0.00
11.4 ZINC ROOFING CODE-A12-09 & 15/A14-01
Basement Floor Sqm 0.00 1.00 0.00
Lower Ground Floor Sqm 0.00 1.00 0.00
Mezzanine Floor Sqm 0.00 1.00 0.00
Ground Floor Sqm 0.00 1.00 0.00
First Floor Sqm 0.00 1.00 0.00
Second Floor Sqm 0.00 1.00 0.00
Third Floor Sqm 0.00 1.00 0.00
Fourth Floor Sqm 0.00 1.00 0.00
Roof Floor Sqm 236.64 1.00 236.64
Total Sqm 236.64 249.00
11.5 KOTA STONE CODE-A12-09 & 4/A14-01
Basement Floor Sqm 0.00 1.00 0.00
Lower Ground Floor Sqm 847.79 1.00 847.79
Mezzanine Floor Sqm 0.00 1.00 0.00
Ground Floor Sqm 0.00 1.00 0.00
First Floor Sqm 0.00 1.00 0.00
Second Floor Sqm 0.00 1.00 0.00
Third Floor Sqm 0.00 1.00 0.00
Fourth Floor Sqm 0.00 1.00 0.00
Total Sqm 847.79 891.00
Basement Floor Sqm 0.00 1.00 0.00
Lower Ground Floor Sqm 0.00 1.00 0.00
Mezzanine Floor Sqm 0.00 1.00 0.00
Ground Floor Sqm 0.00 1.00 0.00
First Floor Sqm 0.00 1.00 0.00
Second Floor Sqm 0.00 1.00 0.00
Third Floor Sqm 0.00 1.00 0.00
Fourth Floor Sqm 0.00 1.00 0.00
Roof Floor Sqm 236.64 1.00 236.64
Total Sqm 236.64 249.00
12 DRAINAGE WALL FINISH
12.1 STONE WALL-LAWN DRAIN CODE-A12-11 & 1/A11-02
Basement Floor Rmt 0.00 1.00 0.00
Lower Ground Floor Rmt 0.00 1.00 0.00
Mezzanine Floor Rmt 0.00 1.00 0.00
Ground Floor Rmt 8.09 1.00 8.09
First Floor Rmt 0.00 1.00 0.00
Second Floor Rmt 0.00 1.00 0.00
Third Floor Rmt 0.00 1.00 0.00
Fourth Floor Rmt 0.00 1.00 0.00
Total Rmt 8.09 9.00
12.2 STONE WALL-STONE FLOOR DRAIN CODE-A12-11 & 2/A11-02
Basement Floor Rmt 0.00 1.00 0.00
Lower Ground Floor Rmt 149.89 1.00 149.89
Mezzanine Floor Rmt 0.00 1.00 0.00
Ground Floor Rmt 12.79 1.00 12.79
First Floor Rmt 0.00 1.00 0.00
Second Floor Rmt 0.00 1.00 0.00
Third Floor Rmt 0.00 1.00 0.00
Fourth Floor Rmt 0.00 1.00 0.00
Total Rmt 162.68 171.00
12.3 ALUM. GLAZING - STONE FLOOR DRAIN CODE-A12-11 & 3/A11-02
Basement Floor Rmt 0.00 1.00 0.00
Lower Ground Floor Rmt 0.00 1.00 0.00
Mezzanine Floor Rmt 0.00 1.00 0.00
Ground Floor Rmt 0.00 1.00 0.00
First Floor Rmt 0.00 1.00 0.00
Second Floor Rmt 0.00 1.00 0.00
Third Floor Rmt 0.00 1.00 0.00
Fourth Floor Rmt 0.00 1.00 0.00
Total Rmt 0.00 0.00
12.4 STONE WALL - STONE FLOOR (WITHOUT PEBBLE) DRAIN CODE-A12-11 & 4/A11-02 check ramp quantity
Basement Floor Rmt 0.00 1.00 0.00
Lower Ground Floor Rmt 0.00 1.00 0.00
Mezzanine Floor Rmt 0.00 1.00 0.00
Ground Floor Rmt 0.00 1.00 0.00
First Floor Rmt 0.00 1.00 0.00
Second Floor Rmt 0.00 1.00 0.00
Third Floor Rmt 0.00 1.00 0.00
Fourth Floor Rmt 59.87 1.00 59.87
Total Rmt 59.87 63.00
12.5 STONE FLOOR - STONE FLOOR DRAIN CODE-A12-11 & 5/A11-02
Basement Floor Rmt 20.12 1.00 20.12
Lower Ground Floor Rmt 1.65 1.00 1.65
Mezzanine Floor Rmt 0.00 1.00 0.00
Ground Floor Rmt 1.65 1.00 1.65
First Floor Rmt 0.00 1.00 0.00
Second Floor Rmt 0.00 1.00 0.00
Third Floor Rmt 0.00 1.00 0.00
Fourth Floor Rmt 132.36 1.00 132.36
Total Rmt 155.78 164.00
12.6 STONE FLOOR - ROAD DRAIN (HEAVY DUTY) CODE-A12-11 & 6/A11-02
Basement Floor Rmt 0.00 1.00 0.00
Lower Ground Floor Rmt 0.00 1.00 0.00
Mezzanine Floor Rmt 0.00 1.00 0.00
Ground Floor Rmt 0.00 1.00 0.00
First Floor Rmt 0.00 1.00 0.00
Second Floor Rmt 0.00 1.00 0.00
Third Floor Rmt 0.00 1.00 0.00
Fourth Floor Rmt 0.00 1.00 0.00
Total Rmt 0.00 0.00
12.7 STONE WALL - ROAD DRAIN CODE-A12-11 & 7/A11-02
Basement Floor Rmt 14.28 1.00 14.28
Lower Ground Floor Rmt 0.00 1.00 0.00
Mezzanine Floor Rmt 0.00 1.00 0.00
Ground Floor Rmt 0.00 1.00 0.00
First Floor Rmt 0.00 1.00 0.00
Second Floor Rmt 0.00 1.00 0.00
Third Floor Rmt 0.00 1.00 0.00
Fourth Floor Rmt 0.00 1.00 0.00
Total Rmt 14.28 15.00
14 COPING FINISH
14.1 COPING 1 CODE-A12-08 & 4/A11-01
Basement Floor Sqm 0.00 1.00 0.00
Lower Ground Floor Sqm 0.00 1.00 0.00
Mezzanine Floor Sqm 0.00 1.00 0.00
Ground Floor Sqm 0.00 1.00 0.00
First Floor Sqm 0.00 1.00 0.00
Second Floor Sqm 0.00 1.00 0.00
Third Floor Sqm 0.00 1.00 0.00
Fourth Floor Sqm 59.62 1.00 59.62
Total Sqm 59.62 63.00
14.2 COPING 2 CODE-A12-08 & 1/A11-01
Basement Floor Sqm 0.00 1.00 0.00
Lower Ground Floor Sqm 74.38 1.00 74.38
Mezzanine Floor Sqm 0.00 1.00 0.00
Ground Floor Sqm 0.00 1.00 0.00
First Floor Sqm 0.00 1.00 0.00
Second Floor Sqm 0.00 1.00 0.00
Third Floor Sqm 0.00 1.00 0.00
Fourth Floor Sqm 0.00 1.00 0.00
Roof Floor Sqm 43.43 1.00 43.43
Total Sqm 117.81 124.00
14.3 COPING 3 CODE-A12-08 & 2/A11-01
Basement Floor Sqm 0.00 1.00 0.00
Lower Ground Floor Sqm 0.00 1.00 0.00
Mezzanine Floor Sqm 0.00 1.00 0.00
Ground Floor Sqm 0.00 1.00 0.00
First Floor Sqm 0.00 1.00 0.00
Second Floor Sqm 0.00 1.00 0.00
Third Floor Sqm 0.00 1.00 0.00
Fourth Floor Sqm 0.00 1.00 0.00
Roof Floor Sqm 0.00 1.00 0.00
Total Sqm 0.00 0.00
14.4 COPING 4 CODE-A12-08 & 3/A11-01
Basement Floor Sqm 0.00 1.00 0.00
Lower Ground Floor Sqm 0.00 1.00 0.00
Mezzanine Floor Sqm 0.00 1.00 0.00
Ground Floor Sqm 0.00 1.00 0.00
First Floor Sqm 0.00 1.00 0.00
Second Floor Sqm 0.00 1.00 0.00
Third Floor Sqm 0.00 1.00 0.00
Fourth Floor Sqm 158.85 1.00 158.85
Roof Floor Sqm 0.00 1.00 0.00
Total Sqm 158.85 167.00
14.6 COPING 5 CODE-A12-08 & 6/A11-01
Basement Floor Sqm 1.00 0.00
Lower Ground Floor Sqm 1.00 0.00
Mezzanine Floor Sqm 1.00 0.00
Ground Floor Sqm 1.00 0.00
First Floor Sqm 1.00 0.00
Second Floor Sqm 1.00 0.00
Third Floor Sqm 1.00 0.00
Fourth Floor Sqm 1.00 0.00
Total Sqm 0.00 0.00
GRANITE COUNTER Cum 18.00 0.075 1.35
25MM THICK STEEL GREY GRANITE FLOORING Cum 311.00 0.075 23.33
25 MM THICK GRAY GRANITE FLOORING Cum 0.00 0.075 0.00
MANDANA-1 (25MM THICK GRANITE) FLOORING Cum 1971.00 0.075 147.82
MANDANA-01 STAIRCASE FLOORING Cum 5.00 0.075 0.38
MANDANA-2 (25MM THICK GRANITE) FLOORING Cum 131.00 0.075 9.82
25MM THICK SANDSTONE Cum 0.00 0.075 0.00
25MM THICK KOTA STONE FLOORING Cum 2162.00 0.075 162.15
25MM THICK KOTA STONE FLOORING Cum 637.00 0.075 47.78
KOTA STONE Cum 0.00 0.075 0.00
10 MM THICK VITRIFIED TILES FLOORING Cum 20.00 0.075 1.50
SS WALK OF MATT Cum 18.00 0.081 1.46
GI WALK OF MATT Cum 5.00 0.081 5.00
VDF CONCERETE FLOORING Cum 291.00 0.000 291.00
(Wooden Deck) Cum 0.00 0.125 0.00
RUBBER TILE FLOORING Cum 15.00 0.075 1.13
Total Cum 692.71 728.00
15 PRECAST PANELS Cum 703.03 1.00 703.03
Total Cum 703.03 739.00
SELF LEVELLING MORTAR
GI WALK OFF GRATING Sqm 4.14 1.000 4.14
SS WALK OFF GRATING Sqm 17.09 1.000 17.09
CARPET TILE FLOORING Sqm 0.00 1.000 0.00
WOODEN DECK FLOORIGN Sqm 0.00 1.000 0.00
RUBBER TILE FLOORING Sqm 13.53 1.000 13.53
Total Sqm 34.77 37.00
@ LOUVER BACKING WITH 19MM PLY + 12MM THK TEAK WOOD PANEL Sqm 80.12 1.00 80.12
Total Sqm 80.12 85.00
@ TEAK WOOD LOUVERS Rmt 312.66 1.00 312.66
Total Rmt 312.66 329.00
SuPr ENGINEERING CONSULTANTS 307, SIDDHARTH UPSCALE, VASNA ROAD VADODARA-390007 TEL- 0265-3149701 MEASUREMENT
PROJECT : GUJARAT VANDANA MUSEUM, GUJARAT
VADODARA ARCHITECT : OPOLIS
DATE : 05-09-25 CLIENT : DIRECTORATE OF ARCHEOLOGY AND MUSEUMS, G.O.G
PREPARED BY : MD CHECKED BY :
SR.NO. PARTICULARS NO. L B D QTY.
2 MASONRY WORK (AAC WALL)
2.3 150MM THICK FLY ASH BLOCK MASONRY CODE-A13-01 & 1/A13-08
Drg Title : GVM_A4_DETAILED PLAN
Drg Date : 11-09-2025
Drg Title : GVM_A4_DETAILED PLAN
Drg Date : 11-09-2025
2.4 200MM THICK FLY ASH BLOCK MASONRY CODE-A13-01 & 1/A13-08
Drg Title : GVM_A4_DETAILED PLAN
Drg Date : 11-09-2025
near exit lobby 1.0 2.50 0.20 3.40 1.70
2.5 250MM THICK FLY ASH BLOCK MASONRY CODE-A13-01 & 1/A13-08
LOWER GROUND FLOOR PLAN
Drg Title : GVM_A4_DETAILED PLAN
Drg Date : 11-09-2025
AHU entrance 1.0 1.85 0.25 4.35 2.01
service atrium 1.0 1.50 0.25 4.35 1.63
GROUND FLOOR PLAN
Drg Title : GVM_A4_DETAILED PLAN
Drg Date : 11-09-2025
Drg Title : GVM_A4_DETAILED PLAN
Drg Date : 11-09-2025
entrance lobby below 1.0 4.81 0.25 4.35 5.23
Drg Title : GVM_A4_DETAILED PLAN
Drg Date : 11-09-2025
Drg Title : GVM_A4_DETAILED PLAN
Drg Date : 11-09-2025
service passage 1.0 3.29 0.25 3.40 2.80
service passage 1.0 2.68 0.25 3.40 2.27
Drg Title : GVM_A4_DETAILED PLAN
Drg Date : 11-09-2025
service terrace 1.0 1.74 0.25 3.43 1.49
2.6 300MM THICK FLY ASH BLOCK MASONRY CODE-A13-01 & 1/A13-08
LOWER GROUND FLOOR PLAN
Drg Title : GVM_A4_DETAILED PLAN
Drg Date : 11-09-2025
siddhi gallery 1.0 3.78 0.30 4.35 4.93
entrance lobby 1.0 1.80 0.30 4.35 2.35
GROUND FLOOR PLAN
Drg Title : GVM_A4_DETAILED PLAN
Drg Date : 11-09-2025
double ht. entrance lobby 1.0 3.25 0.30 4.35 4.24
Drg Title : GVM_A4_DETAILED PLAN
Drg Date : 11-09-2025
service lobby 1.0 3.76 0.30 4.35 4.91
Drg Title : GVM_A4_DETAILED PLAN
Drg Date : 11-09-2025
Drg Title : GVM_A4_DETAILED PLAN
Drg Date : 11-09-2025
Drg Title : GVM_A4_DETAILED PLAN
Drg Date : 11-09-2025
backery + store 1.0 2.85 0.30 3.43 2.93
2.7 350MM THICK FLY ASH BLOCK MASONRY CODE-A13-01 & 1/A13-08
GROUND FLOOR PLAN
Drg Title : GVM_A4_DETAILED PLAN
Drg Date : 11-09-2025
entrance lobby 1.0 7.72 0.35 4.35 11.76
Drg Title : GVM_A4_DETAILED PLAN
Drg Date : 11-09-2025
Drg Title : GVM_A4_DETAILED PLAN
Drg Date : 11-09-2025
2.9 400MM THICK FLY ASH BLOCK MASONRY CODE-A13-01 & 1/A13-08
GROUND FLOOR PLAN
Drg Title : GVM_A4_DETAILED PLAN
Drg Date : 11-09-2025
4.2 200 MM THICK AAC BLOCK MASONRY CODE-01A13-08
LOWER GROUND FLOOR PLAN
Drg Title : GVM_A4_DETAILED PLAN
Drg Date : 11-09-2025
GROUND FLOOR PLAN
Drg Title : GVM_A4_DETAILED PLAN
Drg Date : 11-09-2025
Drg Title : GVM_A4_DETAILED PLAN
Drg Date : 11-09-2025
Drg Title : GVM_A4_DETAILED PLAN
Drg Date : 11-09-2025
4.3 250 MM THICK AAC BLOCK MASONRY CODE-01A13-08
LOWER GROUND FLOOR PLAN
Drg Title : GVM_A4_DETAILED PLAN
Drg Date : 11-09-2025
GROUND FLOOR PLAN
Drg Title : GVM_A4_DETAILED PLAN
Drg Date : 11-09-2025
Drg Title : GVM_A4_DETAILED PLAN
Drg Date : 11-09-2025
service lobby 1.0 6.10 0.25 4.35 6.63
MEZZANINE FLOOR PLAN
Drg Title : GVM_A4_DETAILED PLAN
Drg Date : 11-09-2025
Drg Title : GVM_A4_DETAILED PLAN
Drg Date : 11-09-2025
Drg Title : GVM_A4_DETAILED PLAN
Drg Date : 11-09-2025
Drg Title : GVM_A4_DETAILED PLAN
Drg Date : 11-09-2025
4.4 300 MM THICK AAC BLOCK MASONRY CODE-01A13-08
LOWER GROUND FLOOR PLAN
Drg Title : GVM_A4_DETAILED PLAN
Drg Date : 11-09-2025
DG area & LT Panel area 1.0 0.83 0.30 4.10 1.01
ded of ventilation -1.0 1.45 0.30 0.35 -0.15
Drg Title : GVM_A4_DETAILED PLAN
Drg Date : 11-09-2025
service passage 1.0 0.48 0.30 3.40 0.48
4.5 350 MM THICK AAC BLOCK MASONRY CODE-01A13-08
BASEMENT FLOOR PLAN
Drg Title : GVM_A4_DETAILED PLAN
Drg Date : 11-09-2025
LOWER GROUND FLOOR PLAN
Drg Title : GVM_A4_DETAILED PLAN
Drg Date : 11-09-2025
GROUND FLOOR PLAN
Drg Title : GVM_A4_DETAILED PLAN
Drg Date : 11-09-2025
Drg Title : GVM_A4_DETAILED PLAN
Drg Date : 11-09-2025
Drg Title : GVM_A4_DETAILED PLAN
Drg Date : 11-09-2025
8.1 INTERNAL PLASTER Floor ht = 6.95
Drg Title : FINISHES DIAGRAM-INT WALLS
Drg No : A12-05 Floor ht = 5.10
Drg Date : 25-09-2025 Salb = 0.30
Plaster LT panel area 1.0 29.68 4.80 142.45
add jambs & soffits 1.0 5.70 0.15 0.86
add jambs & soffits 1.0 5.70 0.15 0.86
add jambs & soffits 1.0 10.35 0.15 1.55
Plaster 2.1 wide passage 1.0 8.50 4.80 40.80
add jambs & soffits 1.0 5.70 0.15 0.86
less shaft opn -0.5 0.66 1.80 -0.59
less shaft opn -1.0 2.00 1.80 -3.60
add jambs & soffits 1.0 5.60 0.15 0.84
less shaft opn -1.0 2.00 1.80 -3.60
add jambs & soffits 1.0 5.60 0.15 0.84
less shaft opn -1.0 1.58 1.80 -2.84
add jambs & soffits 1.0 5.18 0.15 0.78
less lift opn -0.5 1.10 2.10 -1.16
add jambs & soffits 1.0 5.70 0.15 0.86
LOWER GROUND FLOOR
Drg Title : FINISHES DIAGRAM-INT WALLS
Drg No : A12-05 Floor ht = 6.90
Drg Date : 25-09-2025 Slab = 0.20
Rev - R0 Total HT = 6.70
Plaster Atrium (A9-23) 1.0 40.48 6.70 271.20
add jambs & soffits 1.0 14.10 0.15 2.12
add jambs & soffits 1.0 11.70 0.15 1.76
Plaster Gal.Lift Lobby 1.0 15.60 6.70 104.52
Ded Of lift lobby -1.0 1.20 2.40 -2.88
Ded Of lift lobby -0.5 1.20 2.40 -1.44
Ded Of lift lobby -0.5 1.20 2.40 -1.44
Plaster Siddhi Gallery 1.0 55.30 6.70 370.51
Plaster AHU 1.0 22.84 6.70 153.05
add jambs & soffits 1.0 5.70 0.15 0.86
Plaster Wall Outside AHU 1.0 2.22 6.70 14.87
Plaster Wall Near Toilet 1.0 22.94 6.70 153.68
Plaster 1.2mm wide passage 1.0 23.05 6.70 154.40
add jambs & soffits 1.0 15.01 0.15 2.25
Plaster 1.2mm wide passage 1.0 28.47 6.70 190.75
Ded Of lift opn -0.5 1.20 2.10 -1.26
add jambs & soffits 1.0 6.30 0.15 0.95
add jambs & soffits 1.0 6.30 0.15 0.95
add jambs & soffits 1.0 7.60 0.15 1.14
add jambs & soffits 1.0 5.70 0.15 0.86
Plaster Lobby Near entrance lobby 2.0 2.83 6.70 37.85
add jambs & soffits 1.0 15.20 0.15 2.28
add jambs & soffits 1.0 7.60 0.15 1.14
Plaster AHU 1.0 25.92 6.70 173.66
add jambs & soffits 1.0 5.70 0.15 0.86
PL BOH SERVICE ATRIUM (nr Toilet A9-25) 1.0 25.56 6.70 171.24
Ded Of Lift opn -0.5 1.20 2.10 -1.26
Ded entrance of toilet -0.5 1.20 2.10 -1.26
PL BOH SERVICE ATRIUM (nr ahu A9-25) 1.0 14.93 6.70 100.00
Drg Title : FINISHES DIAGRAM-INT WALLS
Drg No : A12-05 Floor ht = 6.90
Drg Date : 25-09-2025 Salb = 0.20
plaster AHU 1.0 29.94 p-line 4.45 133.23
add jambs & soffits 1.0 5.70 0.15 0.86
plaster BOH lobby 1.0 27.85 p-line 6.70 186.60
add jambs & soffits 1.0 8.10 0.15 1.22
add jambs & soffits 1.0 8.70 0.15 1.31
plaster 1.2m wide Toilet lobby -0.5 11.75 p-line 6.70 -39.36
add jambs & soffits 1.0 7.25 0.15 1.09
plaster Toilet lobby 1.0 13.63 p-line 6.70 91.29
add jambs & soffits 1.0 7.61 0.15 1.14
plaster Green rm 2.0 4.80 6.70 64.32
Plaster AHU For atrium (A9-23) 1.0 23.64 6.70 158.40
plaster Siddhi gallery- toilet outer wall (A9-24) 1.0 14.44 6.70 96.77
plaster Entrance Lobby wall 2.0 8.32 6.70 111.45
add jambs & soffits 1.0 8.40 0.15 1.26
Drg Title : FINISHES DIAGRAM-INT WALLS
Drg No : A12-05 Floor ht = 6.90
Drg Date : 25-09-2025 Salb = 0.20
PL 1.2m Wide passage 1.0 19.02 6.70 127.40
add jambs & soffits 1.0 15.01 0.15 2.25
add jambs & soffits 1.0 5.70 0.15 0.86
add jambs & soffits 1.0 8.70 0.15 1.31
add jambs & soffits 1.0 14.50 0.15 2.17
add jambs & soffits 1.0 16.20 0.15 2.43
PL Duct Nr AHU 1.0 20.34 6.70 136.25
PL Outer wall nr m toilet 1.0 26.21 7.30 191.32
PL Lobby nr stair-J2 1.0 29.47 6.70 197.48
Ded Of lift opn -1.0 1.20 2.10 -2.52
add jambs & soffits 1.0 6.30 0.15 0.95
add jambs & soffits 1.0 6.30 0.15 0.95
add jambs & soffits 1.0 6.65 0.15 1.00
PL Exit lobby 1.0 22.69 6.70 152.02
Drg Title : FINISHES DIAGRAM-INT WALLS
Drg No : A12-05 Floor ht = 5.10
Drg Date : 25-09-2025 Salb = 0.20
PL BOH LOBBY 1.0 29.67 P-L 4.90 145.36
add jambs & soffits 1.0 8.70 0.15 1.31
LESS LIFT OPN-J5 -1.0 2.80 2.70 -7.56
add jambs & soffits 1.0 8.20 0.15 1.23
LESS LIFT OPN-J4 -0.5 1.20 2.10 -1.26
add jambs & soffits 1.0 6.30 0.15 0.95
add jambs & soffits 1.0 6.30 0.15 0.95
PL VOID AREA 1.0 6.32 4.90 30.96
PL VOID AREA 1.0 5.90 4.90 28.92
PL Siddhi gallery 1.0 5.90 4.90 28.92
PL Ramp side walls 1.0 2.62 4.90 12.82
PL void area 1.0 12.13 P-L 4.90 59.43
BOH lobby outer wall 1.0 7.32 4.90 35.86
Siddhi gallery 2.0 7.40 4.90 72.52
Drg Title : FINISHES DIAGRAM-INT WALLS
Drg No : A12-05 Floor ht = 5.10
Drg Date : 25-09-2025 Salb = 0.20
pl Service passage 1.0 23.77 4.00 95.08
add jambs & soffits 1.0 6.60 0.15 0.99
pl Stair to Service passage lobby 1.0 11.80 4.00 47.20
add jambs & soffits 1.0 9.95 0.15 1.49
add jambs & soffits 1.0 5.82 0.15 0.87
pl Lobby nr AHU exit (A9-24) 1.0 2.30 4.90 11.27
add jambs & soffits 1.0 7.80 0.15 1.17
add jambs & soffits 1.0 6.30 0.15 0.95
add jambs & soffits 1.0 6.30 0.15 0.95
Less Lift opn -1.0 1.20 2.40 -2.88
PL ST-J2 OUTER WALL 1.0 25.23 3.71 93.58
ELEV-J5 OUTER WALL 1.0 5.38 3.71 19.94
Drg Title : FINISHES DIAGRAM-INT WALLS
Drg No : A12-05 Floor ht = 5.10
Drg Date : 25-09-2025 Salb = 0.20
add jambs & soffits 1.0 6.60 0.15 0.99
add jambs & soffits 1.0 5.70 0.15 0.86
add jambs & soffits 1.0 6.28 0.15 0.94
add jambs & soffits 1.0 5.70 0.15 0.86
Lobby Outside kitchen 1.0 9.09 4.69 42.61
PL Lobby (café to kitchen) 2.0 2.63 4.69 24.62
PL Future themed café 1.0 10.83 6.75 73.07
add jambs & soffits 1.0 6.55 0.15 0.98
hvac side wall 1.0 8.90 6.75 60.08
PL Future themed café (A9-24) 1.0 10.53 5.78 60.78
Ded Of lift opn -0.5 1.2 2.40 -1.44
add jambs & soffits 1.0 6.60 0.15 0.99
Lift Lobby 1.0 5.58 5.85 32.61
PL Exirt Lobby 1.0 20.06 5.85 117.33
add jambs & soffits 1.0 6.30 0.15 0.95
add jambs & soffits 1.0 6.30 0.15 0.95
3 TOILET PLASTER
LOWER GROUND FLOOR
Drg Title : FINISHES DIAGRAM-INT WALLS
Drg No : A12-05 Floor ht = 6.90
Drg Date : 25-09-2025 Slab = 0.20
Rev - R0 Total HT = 6.70
Male Toilet 1.0 28.10 P-line 6.70 188.27
Female toilet 1.0 36.17 P-line 6.70 242.32
Male toilet 1.0 8.82 6.70 59.12
Female toilet 1.0 7.26 6.70 48.62
Ground Floor Floor ht = 6.90
Drg Title : FINISHES DIAGRAM-INT WALLS Slab = 0.20
Location : Toilet Total HT = 6.70
Drg No : A12-05
Drg Date : 25-09-2025
Male Toilet 1.0 25.10 P-line 6.70 168.14
Female Toilet 1.0 30.89 P-line 6.70 206.99
1ST FLOOR Floor ht = 6.90
Drg Title : FINISHES DIAGRAM-INT WALLS Slab = 0.20
Location : Toilet Total HT = 6.70
Drg No : A12-05
Drg Date : 25-09-2025
Male Toilet 1.0 24.74 P-line 6.70 165.72
Female Toilet 1.0 27.53 P-line 6.70 184.43
Male Toilet 1.0 22.58 P-line 6.70 151.28
Female Toilet 1.0 23.56 P-line 6.70 157.86
janitor rm 2.0 1.20 6.70 16.08
2ND FLOOR Floor ht = 5.10
Drg Title : FINISHES DIAGRAM-INT WALLS Slab = 0.20
Location : Toilet Total HT = 4.90
Drg No : A12-05
Drg Date : 25-09-2025
F-toilet 1.0 15.92 p-line 4.90 78.01
M-toilet 1.0 6.65 p-line 4.90 32.60
Janitor rm 2.0 1.25 4.90 12.25
4th floor Floor ht = 5.10
Drg Title : FINISHES DIAGRAM-INT WALLS Slab = 0.30
Location : Toilet Total HT = 4.80
Drg No : A12-05
Drg Date : 25-09-2025
F-toilet 1.0 29.26 P-line 4.80 140.43
M-toilet 1.0 28.71 P-line 4.80 137.82
Janitor rm 2.0 1.58 4.80 15.12
8.1 INTERNAL PUTTY WORK Floor ht = 6.95
Drg Title : FINISHES DIAGRAM-INT WALLS
Drg No : A12-05 Floor ht = 5.10
Drg Date : 25-09-2025 Salb = 0.30
less pump rm opn -1.0 4.95 3.80 -18.81
add jambs & soffits 1.0 12.55 0.15 1.88
add jambs & soffits 1.0 13.46 0.15 2.02
add jambs & soffits 1.0 9.70 0.15 1.46
add jambs & soffits 1.0 14.40 0.15 2.16
add jambs & soffits 1.0 14.40 0.15 2.16
Less stair opn -1.0 1.46 5.20 -7.59
add jambs & soffits 1.0 11.86 0.15 1.78
add jambs & soffits 1.0 13.46 0.15 2.02
add jambs & soffits 1.0 14.40 0.15 2.16
Less stair opn -1.0 1.46 4.80 -7.01
add jambs & soffits 1.0 11.06 0.15 1.66
PUTTY Pump rm 1.0 90.63 5.70 516.61
add jambs & soffits 1.0 14.61 0.15 2.19
add jambs & soffits 1.0 12.55 0.15 1.88
add jambs & soffits 1.0 6.30 0.15 0.95
PUTTY Fresh air passage (A9-24) 1.0 58.41 4.80 280.37
less duct opn -1.0 4.53 3.68 -16.66
add jambs & soffits 1.0 11.88 0.15 1.78
less Stair opn -1.0 1.50 4.10 -6.15
add jambs & soffits 1.0 9.70 0.15 1.46
PUTTY LT panel area 1.0 48.73 4.80 233.92
add jambs & soffits 1.0 10.50 0.60 6.30
Less duct opn -1.0 7.73 3.68 -28.41
add jambs & soffits 1.0 6.30 0.15 0.95
PUTTY 2.1 wide passage 1.0 77.68 4.80 372.88
add jambs & soffits 1.0 5.70 0.15 0.86
add jambs & soffits 1.0 6.30 0.15 0.95
add jambs & soffits 1.0 6.30 0.15 0.95
add jambs & soffits 1.0 5.70 0.15 0.86
less lift opn J5 -1.0 2.70 2.80 -7.56
add jambs & soffits 1.0 8.30 0.15 1.25
PUTTY Staircase nr HVAC tank (A9-26) 1.0 24.69 6.75 166.62
add jambs & soffits 1.0 5.70 0.15 0.86
Less stair opn -1.0 1.46 5.20 -7.59
Less stair opn -1.0 1.46 4.80 -7.01
add jambs & soffits 1.0 5.40 0.15 0.81
PUTTY ST-J3 ( BASEMENT TO LGF) 2.0 10.80 4.90 105.84
add jambs & soffits 1.0 5.70 0.15 0.86
LOWER GROUND FLOOR
Drg Title : FINISHES DIAGRAM-INT WALLS
Drg No : A12-05 Floor ht = 6.90
Drg Date : 25-09-2025 Slab = 0.20
Rev - R0 Total HT = 6.70
Putty Atrium 1.0 52.72 6.70 353.24
add jambs & soffits 1.0 9.32 0.15 1.40
Putty Siddhi Gallery 1.0 107.48 6.70 720.10
add jambs & soffits 1.0 5.70 0.15 0.86
Ded of 1.2mm wide opn -1.0 1.61 6.70 -10.79
add jambs & soffits 1.0 15.01 0.15 2.25
add jambs & soffits 1.0 8.70 0.15 1.31
add jambs & soffits 1.0 6.30 0.15 0.95
add jambs & soffits 1.0 10.20 0.15 1.53
add jambs & soffits 1.0 5.70 0.15 0.86
add jambs & soffits 1.0 6.30 0.15 0.95
Putty Rcc Wall Near AHU 1.0 17.53 6.70 117.46
Putty BOH SERVICE ATRIUM 1.0 37.15 6.70 248.92
add jambs & soffits 1.0 8.70 0.15 1.31
Putty Wall At Elev-J5 1.0 19.84 6.70 132.93
Putty Entrance lobby (A6-29 1) 1.0 8.32 6.90 57.44
Entrance lobby (A6-29 2) 1.0 8.80 6.90 60.73
Entrance lobby (A6-29 3) 1.0 9.42 6.90 65.00
Entrance lobby (A6-30 1) 1.0 8.33 6.90 57.48
Drg Title : FINISHES DIAGRAM-INT WALLS
Drg No : A12-05 Floor ht = 4.65
Drg Date : 25-09-2025 Salb = 0.20
putty Outside wall near AHU (A9-25) 1.0 22.38 p-line 4.67 104.51
Outside wall of toilet 1.0 17.11 4.67 79.88
putty AHU For atrium (A9-23) 1.0 33.88 7.00 237.17
putty Lobby near fire exit 1.0 38.34 6.70 256.88
add jambs & soffits 1.0 6.30 0.15 0.95
add jambs & soffits 1.0 6.30 0.15 0.95
add jambs & soffits 1.0 6.30 0.15 0.95
add jambs & soffits 1.0 6.30 0.15 0.95
add jambs & soffits 1.0 6.30 0.15 0.95
putty Siddhi gallery (outer eliptical wall) 1.0 50.59 7.96 402.76
Siddhi gallery (outer eliptical wall) 1.0 38.99 7.96 310.41
putty Siddhi gallery- (A9-25) 1.0 55.90 6.70 374.53
Putty Entrance lobby (A6-29) 1 1.0 8.32 6.90 57.44
Putty Elev - J1 & J2 Wall 1.0 18.15 6.70 121.61
add jambs & soffits 1.0 8.70 0.15 1.31
Putty Gallery lift lobby 1.0 12.15 6.70 81.41
Less lift opns -2.0 1.20 2.40 -5.76
Gallery lift lobby 2.0 16.90 6.70 226.46
add jambs & soffits 2.0 11.90 0.15 3.57
Drg Title : FINISHES DIAGRAM-INT WALLS
Drg No : A12-05 Floor ht = 6.90
Drg Date : 25-09-2025 Salb = 0.20
1.2m Wide passage 1.0 19.02 6.70 127.40
add jambs & soffits 1.0 15.01 0.15 2.25
BOH Lobby 1.0 27.96 27.96
add jambs & soffits 1.0 5.70 0.15 0.86
add jambs & soffits 1.0 8.70 0.15 1.31
add jambs & soffits 1.0 14.50 0.15 2.17
add jambs & soffits 1.0 16.20 0.15 2.43
PU Outer Wall nr AHU 1.0 14.03 7.30 102.40
PU AHU Outer rcc wall 1.0 22.68 7.30 165.56
PU Outer wall exit lobby 1.0 5.81 7.30 42.41
PU Siddhi gallery outer wall 1.0 48.91 7.30 357.01
Putty Gallery lift lobby 1.0 12.15 6.70 81.41
Less lift opns -2.0 1.20 2.40 -5.76
Gallery lift lobby 2.0 16.90 6.70 226.46
add jambs & soffits 2.0 11.90 0.15 3.57
Putty siddhi gallery internal wall 1.0 67.35 6.70 451.25
add jambs & soffits 1.0 6.30 0.15 0.95
add jambs & soffits 1.0 6.30 0.15 0.95
Drg Title : FINISHES DIAGRAM-INT WALLS
Drg No : A12-05 Floor ht = 5.10
Drg Date : 25-09-2025 Salb = 0.20
PU VOID AREA 1.0 5.17 4.90 25.35
PU VOID AREA 1.0 8.78 4.90 43.00
PU Eliptical 1.0 139.80 4.26 595.77
add jambs & soffits 1.0 6.30 0.15 0.95
PU Lift wall 2.0 9.15 4.90 89.67
DED OF LIFT OPN -1.0 1.20 2.10 -2.52
PU Siddhi gallery (St-J2 outer wall) 1.0 7.33 4.90 35.90
add jambs & soffits 1.0 6.30 0.15 0.95
ST-J2 outer wall 1.0 8.95 4.90 43.86
Drg Title : FINISHES DIAGRAM-INT WALLS
Drg No : A12-05 Floor ht = 0.00
Drg Date : 25-09-2025 Slab = 0.00
add jambs & soffits 1.0 6.30 0.15 0.95
Wall bw stair & ramp 1.0 13.33 4.00 53.32
add jambs & soffits 2.0 5.70 0.15 1.71
Outer Wall AHU 1.0 8.87 3.32 29.45
Pu Cut-out wall nr ST-J2 (A9-26) 1.0 25.66 4.67 119.83
add jambs & soffits 1.0 6.30 0.15 0.95
add jambs & soffits 1.0 6.30 0.15 0.95
PU Outer wall 1.0 10.46 7.30 76.36
Future themed café 1.0 10.80 8.36 90.23
RCC ST-J1 OUTER WALL 1.0 7.95 3.71 29.49
Drg Title : FINISHES DIAGRAM-INT WALLS
Drg No : A12-05 Floor ht = 5.10
Drg Date : 25-09-2025 Salb = 0.20
PU Service Terrace wall (A9-23) 1.0 32.38 4.77 154.60
PU RCC wall nr toilet (A9-26) 1.0 13.90 4.67 64.93
14 PRECAST PANELS
avg top and bottom length
LOWER GROUND FLOOR
Drg Title : 2025-09-18_GVM_A4.ELIPTICAL AREA
Drg Date : 01-04-2026
Lower ground floor 1.0 160.46 7.01 1124.49
Ded of Fresh air passage opn -1.0 2.75 2.49 -6.84
Ded of entrance lobby -1.0 5.10 2.95 -15.05
Ded of door from north block (D-J-L-02) -1.0 1.50 2.40 -3.60
Ground Floor 1.0 152.87 7.01 1071.34
Ded of Fresh air passage opn -1.0 2.75 6.90 -18.98
Ded of door from north block (D-J-G-01) -1.0 1.50 2.40 -3.60 3rd 133.899
Ded of Fresh air passage opn -1.0 2.75 6.90 -18.98
Ded of exit bridge -1.0 2.83 4.24 -12.02
Second Floor 1.0 137.69 5.18 713.25
4th floor 1.0 95.87 5.84 559.86 RAMP
Terrace floor 4.0 11.10 2.57 113.93
Parapet wall 1.0 95.87 0.30 28.76
13 WATERPROOFING WORK
13.1 LOCATION : TOILET
LOWER GROUND FLOOR
(Location : ELIPTICAL MALE & FEMALE TOILET)
Drg Title : 2025-09-18_GVM_A0-12_SUNK DIAGRAM
Drg Date : 19-09-2025
Female Toilet 1.0 41.24 P-area 41.24
J.store 1.0 2.63 P-area 2.63
baby care 1.0 5.17 P-area 5.17
Male Toilet 1.0 27.60 P-area 27.60
Passage 1.0 5.94 P-area 5.94
Passage 1.0 11.54 P-area 11.54
Female Toilet 1.0 3.22 P-area 3.22
Male Toilet 1.0 4.88 P-area 4.88
Passage 1.0 2.82 P-area 2.82
Female Toilet 1.0 35.19 P-line 1.00 35.19
J.store 1.0 6.90 P-area 1.00 6.90
baby care 1.0 9.46 P-area 1.00 9.46
Male Toilet 1.0 28.58 P-line 1.00 28.58
Passage 1.0 12.24 P-line 1.00 12.24
Passage 1.0 14.09 P-line 1.00 14.09
Female Toilet 1.0 7.26 P-line 1.00 7.26
Male Toilet 1.0 9.36 P-line 1.00 9.36
Passage 1.0 7.06 P-line 1.00 7.06
(Location : ELIPTICAL MALE & FEMALE TOILET)
Drg Title : 2025-09-18_GVM_A0-12_SUNK DIAGRAM
Drg Date : 19-09-2025
Female Toilet 1.0 32.42 P-area 32.42
J.store 1.0 1.75 P-area 1.75
Baby Care 1.0 5.16 P-area 5.16
Male Toilet 1.0 24.01 P-area 24.01
Passage 1.0 5.83 P-area 5.83
Passage 1.0 11.54 P-area 11.54
Female Toilet 1.0 31.24 P-line 1.00 31.24
Janitor Store 1.0 5.30 P-line 1.00 5.30
Baby Care 1.0 9.45 P-line 1.00 9.45
Male Toilet 1.0 25.52 P-line 1.00 25.52
Passage 1.0 11.97 P-line 1.00 11.97
Passage 1.0 14.11 P-line 1.00 14.11
(Location : ELIPTICAL MALE & FEMALE TOILET)
Drg Title : 2025-09-18_GVM_A0-12_SUNK DIAGRAM
Drg Date : 19-09-2025
Female Toilet 1.0 22.56 P-area 22.56
Male Toilet 1.0 23.19 P-area 23.19
Female Toilet 1.0 27.52 P-line 1.00 27.52
Janitor Store 1.0 5.30 P-line 1.00 5.30
Male Toilet 1.0 24.73 P-line 1.00 24.73
(Location : ELIPTICAL MALE & FEMALE TOILET)
Drg Title : 2025-09-18_GVM_A0-12_SUNK DIAGRAM
Drg Date : 19-09-2025
Female Toilet 1.0 8.47 P-area 8.47
Handicap Toilet 1.0 2.85 P-area 2.85
Female Toilet 1.0 15.92 P-line 1.00 15.92
Janitor Store 1.0 4.70 P-line 1.00 4.70
Handicap Toilet 1.0 6.65 P-line 1.00 6.65
(Location : ELIPTICAL MALE & FEMALE TOILET)
Drg Title : 2025-09-18_GVM_A0-12_SUNK DIAGRAM
Drg Date : 19-09-2025
Kitchen Toilet 1.0 3.90 P-area 3.90
F-Toilet 1.0 27.11 P-area 27.11
M-Toilet 1.0 35.87 P-area 35.87
Female Toilet 1.0 29.26 P-line 1.00 29.26
Male Toilet 1.0 28.70 P-line 1.00 28.70
Toilet 1.0 7.82 P-line 1.00 7.82
13.5 LOCATION : LIFT PIT WATERPROOFING (INSIDE)
(Location : ELIPTICAL LIFT)
Drg Title : 2025-09-18_GVM_A0-12_SUNK DIAGRAM
Drg Date : 19-09-2025
LOWER GROUND FLOOR
(Location : ELIPTICAL LIFT)
Drg Title : 2025-09-18_GVM_A0-12_SUNK DIAGRAM
Drg Date : 19-09-2025
13.5 LOCATION : LIFT PIT WATERPROOFING (OUTSIDE ON WALL)
(Location : ELIPTICAL LIFT)
Drg Title : 2025-09-18_GVM_A0-12_SUNK DIAGRAM
Drg Date : 19-09-2025
LOWER GROUND FLOOR
(Location : ELIPTICAL LIFT)
Drg Title : 2025-09-18_GVM_A0-12_SUNK DIAGRAM
Drg Date : 19-09-2025
TANK WATERPROOFING
(Location : ELIPTICAL TANKS)
Drg Title : 2025-09-18_GVM_A0-12_SUNK DIAGRAM
Drg Date : 19-09-2025
Domestic Tank 1.0 42.87 P-area 42.87
Fire Water Tank 1.0 154.35 P-area 154.35
Raw Water tank 1.0 13.90 P-area 13.90
Rain water tank 1.0 92.83 P-area 92.83
Domestic Water Tank-01 1.0 21.45 4.80 102.96
Domestic Water Tank-02 1.0 21.40 4.80 102.72
Raw Water tank 1.0 14.99 4.80 71.95
Fire Water tank-01 1.0 34.48 4.80 165.50
Fire Water tank-02 1.0 52.09 4.80 250.05
Rain Water tank 1.0 50.30 4.80 241.44
CSE,FSC 2.0 2.80 4.80 26.88 assume
MEZZANINE FLOOR +70.65
(Location : Mez lvl plan +70.65)
Drg Title : GVM_A4_DETAILED PLAN
Drg Date : 11-09-2025
FF Tank 1.0 15.65 P-area 15.65
Domestic Tank 1.0 7.80 P-area 7.80
FF Tank 1.0 15.88 P-line 2.40 38.10
Domestic Tank 1.0 12.74 P-line 2.40 30.58
(Location : Mez lvl plan +70.65)
Drg Title : GVM_A4_DETAILED PLAN
Drg Date : 11-09-2025
Domestic Tank 1.0 4.10 2.16 8.86
FF Tank 1.0 16.83 P-line 1.20 20.20
Domestic Tank 1.0 12.52 P-line 1.20 15.02
TEARRCE WATERPROOFING
2nd Floor Level Plan (above 2nd floor)
(Location : TERRACE)
Drg Title : GVM_A4_DETAILED PLAN
Drg Date : 11-09-2025
On Floor 1.0 94.18 P-area 0.00 AS PER COMMENT RECD-03.06.26
(Location : ELIPTICAL TANKS)
Drg Title : 2025-09-18_GVM_A0-12_SUNK DIAGRAM
Drg Date : 19-09-2025
Pump room 1.0 227.23 P-area 0.30 68.17
DG area 1.0 215.73 P-area 0.30 64.72
LOWER GROUND FLOOR
(Location : ELIPTICAL )
Drg Title : 2025-09-18_GVM_A0-12_SUNK DIAGRAM
Drg Date : 19-09-2025
Male Toilet 1.0 27.39 P-area 0.20 5.48
Female toilet 1.0 48.78 P-area 0.20 9.76
(Location : ELIPTICAL )
Drg Title : 2025-09-18_GVM_A0-12_SUNK DIAGRAM
Drg Date : 19-09-2025
Male Toilet 1.0 23.81 P-area 0.20 4.76
Female toilet 1.0 32.17 P-area 0.20 6.43
(Location : ELIPTICAL )
Drg Title : 2025-09-18_GVM_A0-12_SUNK DIAGRAM
Drg Date : 19-09-2025
Male Toilet 1.0 23.19 P-area 0.20 4.64
Female toilet 1.0 22.56 P-area 0.20 4.51
Male Toilet 1.0 16.95 P-area 0.20 3.39
Female toilet 1.0 16.50 P-area 0.20 3.30
(Location : ELIPTICAL )
Drg Title : 2025-09-18_GVM_A0-12_SUNK DIAGRAM
Drg Date : 19-09-2025
Female toilet 1.0 8.47 P-area 0.20 1.69
Handicaped Toilet 1.0 2.80 P-area 0.20 0.56
(Location : ELIPTICAL )
Drg Title : 2025-09-18_GVM_A0-12_SUNK DIAGRAM
Drg Date : 19-09-2025
(Location : ELIPTICAL )
Drg Title : 2025-09-18_GVM_A0-12_SUNK DIAGRAM
Drg Date : 19-09-2025
Kitchen 1.0 60.88 P-area 0.60 36.53
Kitchen Toilet 1.0 3.90 P-area 0.20 0.78
F-Toilet 1.0 27.11 P-area 0.20 5.42
M-Toilet 1.0 35.87 P-area 0.20 7.17
5 FLOORING WORK
5.1 MANDANA-1 (25MM THICK GRANITE) FLOORING CODE-A12-04 & 1/A14-01
LOWER GROUND FLOOR PLAN
(Location : 1.2m Wide Passage)
Drg Title : GVM_A4_DETAILED PLAN
Drg Date : 11-09-2025
1.2m Wide Passage 1.0 5.78 P-area 5.78
Lobby 1.0 30.56 P-area 30.56
Entrance Lobby 1.0 75.78 75.78
Elev-01 Lobby 1.0 13.19 13.19
GROUND FLOOR LEVEL PLAN
(Location : 1.2m Wide Passage,fire exit lobby,elev-01 lobby)
Drg Title : GVM_A4_DETAILED PLAN
Drg Date : 11-09-2025
1.2m Wide Passage 1.0 5.78 P-area 5.78
Lobby 1.0 32.47 P-area 32.47
Elev-01 Lobby 1.0 17.50 17.50
1ST FLOOR LEVEL PLAN
(Location : 1.2m Wide Passage,fire exit lobby,elev-01 lobby)
Drg Title : GVM_A4_DETAILED PLAN
Drg Date : 11-09-2025
1.2m Wide Passage 1.0 13.06 P-area 13.06
Exit Lobby 1.0 64.10 P-area 64.10
Elev-01 Lobby 1.0 17.50 17.50
2nd FLOOR LEVEL PLAN
(Location : 1.2m Wide Passage,fire exit lobby,elev-01 lobby)
Drg Title : GVM_A4_DETAILED PLAN
Drg Date : 11-09-2025
1.2m Wide Passage 1.0 9.16 P-area 9.16
Exit Lobby 1.0 27.87 P-area 27.87
Elev-01 Lobby 1.0 17.50 17.50
3rd FLOOR LEVEL PLAN
(Location : 1.2m Wide Passage,fire exit lobby,elev-01 lobby)
Drg Title : GVM_A4_DETAILED PLAN
Drg Date : 11-09-2025
Exit lobby 1.0 56.43 P-area 56.43
Exit Lobby 1.0 31.69 P-area 31.69
passage 1.0 6.17 P-area 6.17
Lobby near exit ramp 1.0 6.61 3.00 19.84
lobby near es-j4 1.0 24.22 P-area 24.22
Elipse exit ramp 1.0 26.14 P-area 26.14
4th FLOOR LEVEL PLAN
(Location : 1.2m Wide Passage,fire exit lobby,elev-01 lobby)
Drg Title : GVM_A4_DETAILED PLAN
Drg Date : 11-09-2025
Lobby 1.0 46.58 P-area 46.58
Exit Lobby 1.0 8.51 P-area 8.51
Exit Lobby 1.0 26.58 P-area 26.58
Ramp 1.0 75.51 P-area 75.51
Ramp 1.0 63.51 P-area 63.51
Exit ramp 1.0 48.53 P-area 48.53
5.3 VDF CONCERETE FLOORING CODE-A12-04 & 2/A14-02
LOWER LEVEL GROUND LEVEL PLAN
(Location : SIDDHI GALLERY)
Drg Title : GVM_A4_DETAILED PLAN
Drg Date : 11-09-2025
Siddhi Gallery 1.0 634.67 P-area 634.67
Siddhi Gallery 1.0 484.62 P-area 484.62
GROUND LEVEL PLAN
(Location : SIDDHI GALLERY)
Drg Title : GVM_A4_DETAILED PLAN
Drg Date : 11-09-2025
Siddhi Gallery 1.0 760.15 P-area 760.15
FIRST LEVEL PLAN
(Location : SIDDHI GALLERY)
Drg Title : GVM_A4_DETAILED PLAN
Drg Date : 11-09-2025
Siddhi Gallery 1.0 627.42 P-area 627.42
(Location : SIDDHI GALLERY)
Drg Title : GVM_A4_DETAILED PLAN
Drg Date : 11-09-2025
Siddhi Gallery 1.0 563.04 P-area 563.04
5.5 25MM THICK STEEL GREY GRANITE FLOORING CODE-A12-04 & 1/A14-01
Lower level Ground Floor
(Location : m Toilet, F toilet)
Drg Title : GVM_A4_DETAILED PLAN
Drg Date : 11-09-2025
Male Toilet 1.0 27.39 P-area 27.39
Female Toilet 1.0 48.78 P-area 48.78
Ground Floor Level Plan
(Location : m Toilet, F toilet)
Drg Title : GVM_A4_DETAILED PLAN
Drg Date : 11-09-2025
Male Toilet 1.0 23.81 P-area 23.81
Female Toilet 1.0 32.17 P-area 32.17
Janitor Store 1.0 1.40 1.25 1.75
First Floor Level Plan
(Location : m Toilet, F toilet)
Drg Title : GVM_A4_DETAILED PLAN
Drg Date : 11-09-2025
Male Toilet 1.0 23.19 P-area 23.19
Female Toilet 1.0 22.56 P-area 22.56
Janitor Store 1.0 2.53 1.95 4.92
Female Toilet 1.0 16.50 P-area 16.50
Male Toilet 1.0 16.95 P-area 16.95
2nd Floor Level Plan
(Location : m Toilet, F toilet)
Drg Title : GVM_A4_DETAILED PLAN
Drg Date : 11-09-2025
Toilet-F 1.0 8.47 P-area 8.47
H.Toilet 1.0 2.85 P-area 2.85
4th Floor Level Plan
(Location : m Toilet, F toilet)
Drg Title : GVM_A4_DETAILED PLAN
Drg Date : 11-09-2025
Toilet-M 1.0 35.87 P-area 35.87
Toilet-F 1.0 27.11 P-area 27.11
5.7 MANDANA-2 (25MM THICK GRANITE) FLOORING CODE-A12-04 & 1/A14-01
4th Floor Level Plan
(Location : Future Themed cafe)
Drg Title : GVM_A4_DETAILED PLAN
Drg Date : 11-09-2025
Future themed café 1.0 124.47 P-area 124.47
5.8 RUBBER TILE FLOORING CODE-A12-04 & 3/A14-01
Lower Level Basement Floor
(Location : Babycare)
Drg Title : GVM_A4_DETAILED PLAN
Drg Date : 11-09-2025
(Location : Babycare)
Drg Title : GVM_A4_DETAILED PLAN
Drg Date : 11-09-2025
(Location : Babycare)
Drg Title : GVM_A4_DETAILED PLAN
Drg Date : 11-09-2025
Babycare 1.0 3.01 P-area 3.01
5.9 SS WALK OF MATT CODE-A12-04 & 8/A14-01
LOWER GROUND LEVEL
Drg Title : GVM_A4_DETAILED PLAN
Drg Date : 11-09-2025
ST-E-02 entry 1.0 4.14 P-area 4.14
GROUND FLOOR LEVEL
(Location : LOBBY EXIT )
Drg Title : GVM_A4_DETAILED PLAN
Drg Date : 11-09-2025
Exit ramp 1.0 5.02 P-area 5.02
3rd Floor LEVEL
Drg Title : GVM_A4_DETAILED PLAN
Drg Date : 11-09-2025
Exit ramp 1.0 3.30 P-area 3.30
4th Floor LEVEL
Drg Title : GVM_A4_DETAILED PLAN
Drg Date : 11-09-2025
service 1.0 1.39 P-area 1.39
6 WALL FINISH WORK
6.1 SANDSTONE CLADDING DRG CODE- A12-05 REF : 6/A14-02
Lower ground floor
Drg Title : FINISHES DIAGRAM-INT WALLS
Drg No : A12-05
Drg Date : 25-09-2025
1.2m wide passage near toilet 1.0 23.05 P-line 3.00 69.14
entrance lobby (A6-29) 1.0 8.07 2.10 16.96
Drg Title : FINISHES DIAGRAM-INT WALLS
Drg No : A12-05
Drg Date : 25-09-2025
1.2m wide passage near toilet (A6-30) 1.0 23.05 P-line 3.00 69.14
entrance lobby (A6-29 1) 1.0 8.08 6.90 55.75
Drg Title : FINISHES DIAGRAM-INT WALLS
Drg No : A12-05
Drg Date : 25-09-2025
1.2m wide passage near toilet (A6-33) 1.0 23.05 P-line 3.00 69.14
Ded of lift opn -1.0 1.20 2.40 -2.88
Exit lobby 1.0 7.36 3.00 22.08
Entrance lobby 1.0 10.53 3.00 31.58
Drg Title : FINISHES DIAGRAM-INT WALLS
Drg No : A12-05
Drg Date : 25-09-2025
1.2m wide passage near toilet (A6-33) 1.0 14.72 P-line 3.00 44.15
Exit lobby 1.0 7.36 3.00 22.08
Entrance lobby as per A6-33 1.0 12.44 3.00 37.31
Drg Title : FINISHES DIAGRAM-INT WALLS
Drg No : A12-05
Drg Date : 25-09-2025
Ded Of Lift opn -1.0 1.10 2.10 -2.31
Drg Title : FINISHES DIAGRAM-INT WALLS
Drg No : A12-05
Drg Date : 25-09-2025
Service station wall (A6-37) 1.0 1.95 5.85 11.41
Service station wall (A6-37 4 ) 1.0 1.97 5.85 11.50
Service station wall (A6-37 4 ) 1.0 5.58 5.85 32.61
Service station wall (A6-37 4 ) 1.0 2.40 6.15 14.76
Service station wall (A6-37 4 ) 1.0 1.20 6.45 7.74
Service station wall (A6-37 4 ) 1.0 1.38 6.45 8.87
Ded of lift opn -1.0 1.20 2.40 -2.88
Lift Lobby to view deck 1.0 3.84 5.80 22.27
6.2 FIRE RATED GYPSUM BOARD + PAINT DRG CODE- A12-05 REF : 17/A14-02
Lower Gorund Floor
Drg Title : FINISHES DIAGRAM-INT WALLS
Drg No : A12-05
Drg Date : 25-09-2025
Siddhi Gallery (A6-31 6 ) 1.0 153.14 P-line 4.80 735.06
Ded of lift Lobby Opn -2.0 1.50 3.60 -10.80
Ded of lift lobby -1.0 5.95 3.23 -4.80
Ded of lift lobby -1.0 2.66 3.23 -4.80
Drg Title : FINISHES DIAGRAM-INT WALLS
Drg No : A12-05
Drg Date : 25-09-2025
Siddhi gallery 1.0 178.10 P-line 4.80 854.89
Atrium wall 2.0 13.94 4.80 133.80
lobby wall 1.0 6.87 4.80 32.98
ded of lobby opn -2.0 1.50 4.80 -14.40
ded of stair opn -2.0 1.36 4.80 -13.06
Drg Title : FINISHES DIAGRAM-INT WALLS
Drg No : A12-05
Drg Date : 25-09-2025
Siddhi gallery 1.0 162.79 P-line 4.80 781.38
Atrium wall 2.0 13.94 4.80 133.80
lobby wall 1.0 6.87 4.80 32.98
ded of lobby opn -2.0 1.50 4.80 -14.40
ded of stair opn -2.0 1.36 4.80 -13.06
Drg Title : FINISHES DIAGRAM-INT WALLS
Drg No : A12-05
Drg Date : 25-09-2025
Siddhi gallery 1.0 162.79 P-line 4.80 781.38
Atrium wall 2.0 13.94 4.80 133.80
lobby wall 1.0 6.87 4.80 32.98
ded of lobby opn -2.0 1.50 4.80 -14.40
ded of stair opn -2.0 1.36 4.80 -13.06
6.3 WOODEN PANELING DRG CODE- A12-05 REF : 7/A14-02
Lower Ground Floor
Drg Title : FINISHES DIAGRAM-INT WALLS
Location : Lift Lobby
Drg No : A12-05
Drg Date : 25-09-2025
Ded Of lift Claddding -1.0 5.70 3.00 -17.1
Entrance lobby D-J-L-08 1.0 1.33 2.40 3.192
Lobby entry D-J-L-07 1.0 2.00 2.40 4.8
Entrance lobby 1.0 1.25 2.40 3.00
Entrance lobby 1.0 8.43 6.90 58.19
Drg Title : FINISHES DIAGRAM-INT WALLS
Location : Lift Lobby
Drg No : A12-05
Drg Date : 25-09-2025
Ded Of lift Claddding -1.0 5.70 3.00 -17.1
Entrance lobby W-J-G-02 1.0 1.33 2.40 3.192
Entrance lobby 1.0 1.25 2.40 3.00
Entrance lobby 1.0 8.42 6.90 58.13
Ded Of Fixed Glass -1.0 2.96 3.90 -11.53
Drg Title : FINISHES DIAGRAM-INT WALLS
Location : Lift Lobby
Drg No : A12-05
Drg Date : 25-09-2025
Ded Of lift Claddding -1.0 5.70 3.00 -17.1
Lobby entry 2.0 1.00 4.80 9.60
Drg Title : FINISHES DIAGRAM-INT WALLS
Location : Lift Lobby
Drg No : A12-05
Drg Date : 25-09-2025
Ded Of lift Claddding -1.0 5.70 3.00 -17.1
6.4 MANDANA STONE-3 CLADDING DRG CODE- A12-05 REF : 6/A14-02
Lower Ground Floor
Drg Title : FINISHES DIAGRAM-INT WALLS
Location : Lift lobby
Drg No : A12-05
Drg Date : 25-09-2025
Lift lobby wall cladding (A6-31 2) 1.0 5.70 3.00 17.10
Ded Of lift opn -2.0 1.20 2.40 -5.76
Lift Jambs & soffits 2.0 6.00 0.44 5.28
Entrance looby cladding (A6-30 elev 1 ) 1.0 7.70 avg 6.90 53.11
Entrance looby cladding (A6-29 elev 2 ) 1.0 8.91 avg 6.90 61.51
Drg Title : FINISHES DIAGRAM-INT WALLS
Location : Lift lobby
Drg No : A12-05
Drg Date : 25-09-2025
Lift lobby wall cladding (A6-31 elev 2) 1.0 5.70 3.00 17.10
Ded Of lift opn -2.0 1.20 2.40 -5.76
Lift Jambs & soffits 2.0 6.00 0.44 5.28
Entrance looby cladding (A6-31 elev 1 ) 1.0 6.65 avg 6.00 39.88
Ded Of fixed glass -1.0 1.20 3.60 -4.32
Above Area 1.0 4.67 0.90 4.21
Entrance looby cladding (A6-31 elev 2 ) 1.0 7.63 avg 6.00 45.80
Drg Title : FINISHES DIAGRAM-INT WALLS
Location : Lift lobby
Drg No : A12-05
Drg Date : 25-09-2025
Lift lobby wall cladding (A6-31 elev 2) 1.0 5.70 3.00 17.10
Ded Of lift opn -2.0 1.20 2.40 -5.76
Lift Jambs & soffits 2.0 6.00 0.44 5.28
Entrance looby cladding (A6-31 elev 1 ) 1.0 6.65 avg 6.00 39.88
Ded Of fixed glass -1.0 1.20 3.60 -4.32
Above Area 1.0 4.67 0.90 4.21
Entrance looby cladding (A6-31 elev 2 ) 1.0 7.63 avg 6.00 45.80
Drg Title : FINISHES DIAGRAM-INT WALLS
Location : Lift lobby
Drg No : A12-05
Drg Date : 25-09-2025
Lift lobby wall cladding (A6-31 elev 2) 1.0 5.70 3.00 17.10
Ded Of lift opn -2.0 1.20 2.40 -5.76
Lift Jambs & soffits 2.0 6.00 0.44 5.28
Entrance looby cladding (A6-31 elev 1 ) 1.0 6.65 avg 6.00 39.88
Ded Of fixed glass -1.0 1.20 3.60 -4.32
Above Area 1.0 4.67 0.90 4.21
Entrance looby cladding (A6-31 elev 2 ) 1.0 7.63 avg 6.00 45.80
Drg Title : FINISHES DIAGRAM-INT WALLS
Location : Lift lobby
Drg No : A12-05
Drg Date : 25-09-2025
Ded Of Fixed glass -2.0 2.20 1.80 -7.92
Exit Ramp Opn -1.0 1.68 2.40 -4.03
6.5 GRANITE CLADDING DRG CODE- A12-05 REF : 6/A14-02
Drg Title : FINISHES DIAGRAM-INT WALLS
Location : Lift lobby
Drg No : A12-05
Drg Date : 25-09-2025
Lift lobby walls
Lower Ground Floor
Drg Title : FINISHES DIAGRAM-INT WALLS
Location : Lift lobby
Drg No : A12-05
Drg Date : 25-09-2025
Lift lobby walls
Drg Title : FINISHES DIAGRAM-INT WALLS
Location : Lift lobby
Drg No : A12-05
Drg Date : 25-09-2025
Lift Lobby Walls
Drg Title : FINISHES DIAGRAM-INT WALLS
Location : Lift lobby
Drg No : A12-05
Drg Date : 25-09-2025
Lift Lobby Walls
Drg Title : FINISHES DIAGRAM-INT WALLS
Location : Lift lobby
Drg No : A12-05
Drg Date : 25-09-2025
Lift Lobby Walls
Drg Title : FINISHES DIAGRAM-INT WALLS
Location : Lift lobby
Drg No : A12-05
Drg Date : 25-09-2025
Lift Lobby Walls
6.6 S.S CLADDING DRG CODE- A12-05 REF : 13/A14-02
Lower Ground Floor
Drg Title : FINISHES DIAGRAM-INT WALLS
Drg No : A12-05
Drg Date : 25-09-2025
Entrance lobby 1.0 2.67 6.90 18.42
6.7 VITRIFIED TILES CLADDING DRG CODE- A12-05 REF : 8/A14-02
Lower Ground Floor
Drg Title : FINISHES DIAGRAM-INT WALLS
Drg No : A12-05
Drg Date : 25-09-2025
Male Toilet 1.0 28.10 P-line 3.00 84.30
Female toilet 1.0 36.17 P-line 3.00 108.50
Drg Title : FINISHES DIAGRAM-INT WALLS
Location : Toilet
Drg No : A12-05
Drg Date : 25-09-2025
Male Toilet 1.0 25.10 P-line 3.00 75.29
Female Toilet 1.0 30.89 P-line 3.00 92.68
Drg Title : FINISHES DIAGRAM-INT WALLS
Location : Toilet
Drg No : A12-05
Drg Date : 25-09-2025
Male Toilet 1.0 24.74 P-line 3.00 74.21
Female Toilet 1.0 27.53 P-line 3.58 98.55
Male Toilet 1.0 22.58 P-line 3.00 67.74
Female Toilet 1.0 23.56 P-line 3.58 84.35
janitor rm 2.0 1.20 3.00 7.20
Drg Title : FINISHES DIAGRAM-INT WALLS
Location : Toilet
Drg No : A12-05
Drg Date : 25-09-2025
F-toilet 1.0 15.92 p-line 3.00 47.76
M-toilet 1.0 6.65 p-line 3.00 19.96
Janitor rm 2.0 1.25 3.00 7.50
Drg Title : FINISHES DIAGRAM-INT WALLS
Location : Toilet
Drg No : A12-05
Drg Date : 25-09-2025
F-toilet 1.0 29.26 P-line 3.00 87.77
M-toilet 1.0 28.71 P-line 3.00 86.14
Janitor rm 2.0 1.58 3.00 9.45
8 FALSE CEILING WORK
8.3 GYPSUM + ACOUSTIC LINING CODE-A12-07 & 1/A14-04
LOWER GROUND FLOOR LEVEL PLAN
(Location : 1.2m wide toilet passage,lift lobby)
Drg Title : GVM_A12_07_Int Ceiling Diagram
Drg Date : 18-09-2025
1.2m wide Toilet Passage 1.0 16.99 P-area 16.99
Lift lobby 1.0 28.76 P-area 28.76
GROUND FLOOR LEVEL PLAN
(Location : Toilet Passage,Lift Lobby)
Drg Title : GVM_A12_07_Int Ceiling Diagram
Drg Date : 18-09-2025
1.2m wide Toilet Passage 1.0 5.70 P-area 5.70
Lift lobby 1.0 42.66 P-area 42.66
Janitor Store 1.0 1.40 1.25 1.75
1ST FLOOR LEVEL PLAN
(Location : 1.2m Passage,Exit lobby)
Drg Title : GVM_A12_07_Int Ceiling Diagram
Drg Date : 18-09-2025
1.2m Wide Passage 1.0 12.45 P-area 12.45
Exit Lobby 1.0 157.38 P-area 157.38
Ramp 2nd Floor To 1st Floor 1.0 217.75 P-area 217.75
2nd FLOOR LEVEL PLAN
(Location : Toilet Passage,Exit lobby)
Drg Title : GVM_A12_07_Int Ceiling Diagram
Drg Date : 18-09-2025
Toilet Passage 1.0 9.15 P-area 9.15
Exit Lobby 1.0 27.34 P-area 27.34
3RD FLOOR LEVEL PLAN
(Location : Toilet Passage,Exit Ramp,Exit lobby)
Drg Title : GVM_A12_07_Int Ceiling Diagram
Drg Date : 18-09-2025
Lobby 1.0 24.22 P-area 24.22
Exit Ramp 1.0 67.57 P-area 67.57
Exit Lobby 1.0 56.43 P-area 56.43
Passage 1.0 4.89 P-area 4.89
Exit Lobby 1.0 31.69 P-area 31.69
Ramp 3rd To 2nd Floor 1.0 274.60 P-area 274.60
ST-J7 1.0 8.62 P-area 8.62
4TH FLOOR LEVEL PLAN
(Location : café Passage,lobby)
Drg Title : GVM_A12_07_Int Ceiling Diagram
Drg Date : 18-09-2025
Café Passage 1.0 2.60 P-area 2.60
Lobby 1.0 7.60 P-area 7.60
Lobby 1.0 17.21 P-area 17.21
8.5 WOODEN CEILING CODE-A12-07 & 9/A14-04
LOWER GROUND LEVEL PLAN
(Location : Lift Lobby)
Drg Title : GVM_A12_07_Int Ceiling Diagram
Drg Date : 18-09-2025
Lift lobby 1.0 14.97 P-area 14.97
GROUND FLOOR LEVEL PLAN
(Location : Lift Lobby,Entrance Lobby)
Drg Title : GVM_A12_07_Int Ceiling Diagram
Drg Date : 18-09-2025
Lift lobby 1.0 14.97 P-area 14.97
Entrance lobby 1.0 29.87 P-area 29.87
1ST FLOOR LEVEL PLAN
(Location : Lift Lobby)
Drg Title : GVM_A12_07_Int Ceiling Diagram
Drg Date : 18-09-2025
Lift lobby 1.0 14.97 P-area 14.97
2nd FLOOR LEVEL PLAN
(Location : Lift Lobby)
Drg Title : GVM_A12_07_Int Ceiling Diagram
Drg Date : 18-09-2025
Lift lobby 1.0 14.97 P-area 14.97
5.9 25MM THICK KOTA STONE FLOORING CODE-A12-04 & 4/A14-01
(Location : DG AREA,PUMP ROOM,LT PANEL AREA,Pump Room,FRESH AIR PASSAGE)
Drg Title : GVM_A4_DETAILED PLAN
Drg Date : 11-09-2025
DG Area 2 1.0 215.73 P-area 215.73
DG Area 2 near staircase 1.0 32.43 P-area 32.43
DG Area 1 1.0 81.37 P-area 81.37
LT Panel Area 1.0 197.96 P-area 197.96
2.1m Passage Area 1.0 200.88 P-area 200.88
Pump Room 1.0 227.23 P-area 227.23
Fresh Air Passage 1.0 66.82 P-area 66.82
Pump Room 1.0 55.37 P-area 55.37
Lower Ground Level Plan
(Location : F.F,AV SYSTEM)
Drg Title : GVM_A4_DETAILED PLAN
Drg Date : 11-09-2025
Av Systems 1.0 2.55 P-area 2.55
FF 1.0 2.55 P-area 2.55
AHU 1.0 41.72 P-area 41.72
Service Atrium 1.0 260.72 P-area 260.72
Ded OF Stair Area -1.0 22.31 P-area -22.31
AHU Entrance Lobby 1.0 29.14 P-area 29.14
Shaft DoorDS-J L-03 1.0 0.60 0.25 0.15
Ground Level Plan
(Location : AHU,BOH Lobby,Green Room,Av System,FF)
Drg Title : GVM_A4_DETAILED PLAN
Drg Date : 11-09-2025
AHU 1.0 55.32 P-area 55.32
BOH Gallery 1.0 37.81 P-area 37.81
Green Room 1.0 4.03 4.80 19.32
Av Systems 1.0 2.55 P-area 2.55
FF 1.0 2.55 P-area 2.55
Shaft DoorDS-J G-07 1.0 0.60 0.25 0.15
1st Floor Level Plan
(Location : AHU,Service lobby,Av System,FF)
Drg Title : GVM_A4_DETAILED PLAN
Drg Date : 11-09-2025
AHU 1.0 99.90 P-area 99.90
Service lobby 1.0 38.08 P-area 38.08
Av Systems 1.0 2.55 P-area 2.55
FF 1.0 2.55 P-area 2.55
Shaft Door DS-J G-07 1.0 0.60 0.25 0.15
FF House 1.0 1.11 P-area 1.11
2nd Floor Level Plan
(Location : AHU,BOH Lobby,Av System,FF)
Drg Title : GVM_A4_DETAILED PLAN
Drg Date : 11-09-2025
BOH Lobby 1.0 43.42 P-area 43.42
Av Systems 1.0 2.55 P-area 2.55
FF 1.0 2.55 P-area 2.55
FF 1.0 0.79 P-area 0.79
FF 1.0 0.76 P-area 0.76
3rd Floor Level Plan
(Location : AHU,Service Passage)
Drg Title : GVM_A4_DETAILED PLAN
Drg Date : 11-09-2025
AHU 1.0 74.67 P-area 74.67
FF 1.0 0.64 P-area 0.64
Passage 1.0 8.42 P-area 8.42
Passage 1.0 9.53 P-area 9.53
AHU 1.0 30.70 P-area 30.70
AHU 1.0 23.75 P-area 23.75
Passage 1.0 12.03 P-area 12.03
Service Passage 1.0 36.16 P-area 36.16
4th Floor Level Plan
(Location : Kitchen,Service Terrace,Bakery,FF)
Drg Title : GVM_A4_DETAILED PLAN
Drg Date : 11-09-2025
Kitchen 1.0 60.88 P-area 60.88
Kitchen 1.0 4.53 P-area 4.53
Bakery 1.0 27.16 P-area 27.16
Service terrace 1.0 46.65 P-area 46.65
FF 2.0 0.79 P-area 1.58
5.10 SEALED CONCRETE FLOORING CODE-A12-04 & 13A/A14-01
(Location : ELEV-E-05,ELEV-E-04,SHAFT)
Drg Title : GVM_A4_DETAILED PLAN
Drg Date : 11-09-2025
Shaft At Pump Room 1.0 12.46 P-area 12.46
Shaft At Fresh Ar Trench 1.0 30.54 P-area 30.54
Shaft At LT Panel Area 1.0 12.36 P-area 12.36
Lower Ground Level Plan
(Location : F.F,AV SYSTEM)
Drg Title : GVM_A4_DETAILED PLAN
Drg Date : 11-09-2025
5.11 GI WALK OF MATT CODE-A12-04 & 8/A14-01
LOWER GROUND LEVEL
Drg Title : GVM_A4_DETAILED PLAN
Drg Date : 11-09-2025
ST-E-02 entry 1.0 4.14 P-area 4.14
GROUND FLOOR LEVEL
(Location : LOBBY EXIT )
Drg Title : GVM_A4_DETAILED PLAN
Drg Date : 11-09-2025
3rd Floor LEVEL
Drg Title : GVM_A4_DETAILED PLAN
Drg Date : 11-09-2025
Exit ramp 1.0 3.30 P-area 3.30
4th Floor LEVEL
Drg Title : GVM_A4_DETAILED PLAN
Drg Date : 11-09-2025
service 1.0 1.39 P-area 1.39
5.12 GRATING CODE-A12-04 & 6/A14-01
LOWER GROUND LEVEL
(Location : SHAFTS)
Drg Title : GVM_A4_DETAILED PLAN
Drg Date : 11-09-2025
Shaft 1.0 28.87 P-area 28.87
Shaft 1.0 13.19 P-area 13.19
Shaft 1.0 11.89 P-area 11.89
GROUND LEVEL PLAN
(Location : SHAFTS)
Drg Title : GVM_A4_DETAILED PLAN
Drg Date : 11-09-2025
Service passage 1.0 4.67 P-area 4.67
(Location : SHAFTS)
Drg Title : GVM_A4_DETAILED PLAN
Drg Date : 11-09-2025
Service passage 1.0 4.81 P-area 4.81
5.13 8MM THICK WHITE GLAZED TILES CODE-A12-04 & 11/A14-01
(Location : hvac tank,domestic tanlk 1&2,rain water tank,fire water tank 1&2,Rain Water tank,Bm-2,EQT,WW,TS,CTO,BM-1,ct-1,ct-2,tw-1,tw-2)
Drg Title : GVM_A4_DETAILED PLAN
Drg Date : 11-09-2025
Domestic Tank 1.0 42.87 P-area 42.87
Fire Water Tank 1.0 154.35 P-area 154.35
Raw Water tank 1.0 13.90 P-area 13.90
Rain water tank 1.0 92.83 P-area 92.83
MEZZANINE FLOOR +70.65
(Location : Mez lvl plan +70.65)
Drg Title : GVM_A4_DETAILED PLAN
Drg Date : 11-09-2025
Tank 1.0 15.65 P-area 15.65
Tank 1.0 7.80 P-area 7.80
OHT FLOOR +70.65
(Location : Mez lvl plan +70.65)
Drg Title : GVM_A4_DETAILED PLAN
Drg Date : 11-09-2025
5.14 10 MM THICK VITRIFIED TILES FLOORING CODE-A12-04 & 7/A14-01
(Location : Male Toilet,Female Toilet, 1.2m Wide passage)
Drg Title : GVM_A4_DETAILED PLAN
Drg Date : 11-09-2025
Male Toilet 1.0 4.66 P-area 4.66
Female Toilet 1.0 3.19 P-area 3.19
1.2 m Wide Passage 1.0 2.70 P-area 2.70
(Location : Janitor Rm)
Drg Title : GVM_A4_DETAILED PLAN
Drg Date : 11-09-2025
Janitor Rm 1.0 1.25 1.20 1.50
(Location : Janitor Rm,Toilet)
Drg Title : GVM_A4_DETAILED PLAN
Drg Date : 11-09-2025
Janitor Rm 1.0 1.94 P-area 1.94
Toilet 1.0 3.90 P-area 3.90
5 FLOORING WORK
5.20 25MM THICK KOTA STONE FLOORING CODE-A12-04 & 4/A14-01 (LOCATION : Staircase)
Basement Floor As per A7_staricase & ramp details
(Location : Stairacse)
Drg Title : GVM_A4_DETAILED PLAN
Drg Date : 11-09-2025
Floor Landing 1.0 21.61 P-area 21.61
Mid-landing 2.0 4.70 P-area 9.40
Floor Landing 1.0 46.43 P-area 46.43
Mid-landing-2 1.0 8.96 P-area 8.96
Lower Ground Level Plan As per A7_staricase & ramp details
(Location : Stairacse)
Drg Title : GVM_A4_DETAILED PLAN
Drg Date : 11-09-2025
Floor Landing-01 (-9900mm) 1.0 33.36 P-area 33.36
Mid-landing-2 (-8100mm) 1.0 8.73 P-area 8.73
Mid-landing-3 (-6450mm) 1.0 8.90 P-area 8.90
Mid-landing-4 (-4800mm) 1.0 8.73 P-area 8.73
Floor Landing-01 1.0 14.82 P-area 14.82
Floor Landing-02 1.0 31.53 P-area 31.53
Mid-landing-3 1.0 8.90 P-area 8.90
Mid-landing-4 1.0 8.90 P-area 8.90
Floor Landing-4 1.0 4.30 2.00 8.60
Mid-landing-6 1.0 9.21 P-area 9.21
Floor Landing-8 1.0 9.80 P-area 9.80
Mid-landing-9 1.0 2.00 1.96 3.92
Floor Landing-10 1.0 9.23 P-area 9.23
Floor Landing 1.0 5.18 P-area 5.18
Ground Level Plan As per A7_staricase & ramp details
(Location : Stairacse)
Drg Title : GVM_A4_DETAILED PLAN
Drg Date : 11-09-2025
Floor Landing-05 (-3000mm) 1.0 11.04 P-area 11.04
Mid-landing-6 (-1350mm) 1.0 8.90 P-area 8.90
Mid-landing-7 (+450mm) 1.0 8.90 P-area 8.90
Mid-landing-8 (+2100mm) 1.0 8.90 P-area 8.90
Floor Landing-(-3.000mm) 1.0 10.26 P-area 10.26
Mid-landing-6 (-1200mm) 1.0 8.90 P-area 8.90
Mid-landing-7 (+450mm) 1.0 9.50 P-area 9.50
Mid-landing-8 (+2250mm) 1.0 8.90 P-area 8.90
1st Level Plan As per A7_staricase & ramp details
(Location : Stairacse)
Drg Title : GVM_A4_DETAILED PLAN
Drg Date : 11-09-2025
Floor Landing-09 (3900mm) 1.0 11.04 P-area 11.04
Mid-landing-10 (+5550mm) 1.0 8.90 P-area 8.90
Mid-landing-11 (+7350mm) 1.0 8.90 P-area 8.90
Mid-landing-12 (+9000mm) 1.0 8.90 P-area 8.90
Floor Landing-(+3900mm) 1.0 10.26 P-area 10.26
Mid-landing-10 (+5700mm) 1.0 8.90 P-area 8.90
Mid-landing-11 (+7350mm) 1.0 8.90 P-area 8.90
Mid-landing-12 (+9150mm) 1.0 8.90 P-area 8.90
Mez lvl Plan (+70.65)
(Location : Stairacse)
Drg Title : GVM_A4_DETAILED PLAN
Drg Date : 11-09-2025
AHU 1.0 28.09 P-area 28.09
2nd Level Plan As per A7_staricase & ramp details
(Location : Stairacse)
Drg Title : GVM_A4_DETAILED PLAN
Drg Date : 11-09-2025
Floor Landing-013 (10800mm) 1.0 11.04 P-area 11.04
Mid-landing-14 (+12450mm) 1.0 8.90 P-area 8.90
Mid-landing-15 (+14250mm) 1.0 8.90 P-area 8.90
Floor Landing-(+10800mm) 1.0 14.08 P-area 14.08
Mid-landing-14 (+12450mm) 1.0 9.48 P-area 9.48
Mid-landing-15 (+14250mm) 1.0 8.90 P-area 8.90
3rd Level Plan As per A7_staricase & ramp details
(Location : Stairacse)
Drg Title : GVM_A4_DETAILED PLAN
Drg Date : 11-09-2025
Floor Landing-016 (15900mm) 1.0 11.04 P-area 11.04
Mid-landing-17 (+17550mm) 1.0 8.90 P-area 8.90
Mid-landing-18 (+19350mm) 1.0 8.90 P-area 8.90
Floor Landing-(+15900mm) 1.0 9.90 P-area 9.90
Mid-landing-17 (+17550mm) 1.0 10.99 P-area 10.99
Mid-landing-18 (+19350mm) 1.0 8.90 P-area 8.90
Floor Landing-(+20400mm) 1.0 18.82 P-area 18.82
4th Level Plan As per A7_staricase & ramp details
(Location : Stairacse)
Drg Title : GVM_A4_DETAILED PLAN
Drg Date : 11-09-2025
Floor Landing-019 (15900mm) 1.0 6.60 P-area 6.60
5.21 25MM THICK KOTA STONE-TREADS CODE-A12-04 & 4/A14-01 (LOCATION : Staircase)
As per A7_staricase & ramp details
(Location : Stairacse)
Drg Title : GVM_A4_DETAILED PLAN
Drg Date : 11-09-2025
DG-Area 2 staircse 12.0 1.98 23.70
Fresh air passsage 12.0 1.45 17.40
LOWER GROUND FLOOR As per A7_staricase & ramp details
(Location : Stairacse)
Drg Title : GVM_A4_DETAILED PLAN
Drg Date : 11-09-2025
GROUND FLOOR As per A7_staricase & ramp details
(Location : Stairacse)
Drg Title : GVM_A4_DETAILED PLAN
Drg Date : 11-09-2025
1st Level Plan As per A7_staricase & ramp details
(Location : Stairacse)
Drg Title : GVM_A4_DETAILED PLAN
Drg Date : 11-09-2025
2nd Level Plan As per A7_staricase & ramp details
(Location : Stairacse)
Drg Title : GVM_A4_DETAILED PLAN
Drg Date : 11-09-2025
3rd Level Plan As per A7_staricase & ramp details
(Location : Stairacse)
Drg Title : GVM_A4_DETAILED PLAN
Drg Date : 11-09-2025
5.22 25MM THICK KOTA STONE-RISERS CODE-A12-04 & 4/A14-01 (LOCATION : Staircase)
As per A7_staricase & ramp details
(Location : Stairacse)
Drg Title : GVM_A4_DETAILED PLAN
Drg Date : 11-09-2025
DG-Area 2 staircse 13.0 1.98 25.68
Fresh air passsage 13.0 1.45 18.85
LOWER GROUND FLOOR As per A7_staricase & ramp details
(Location : Stairacse)
Drg Title : GVM_A4_DETAILED PLAN
Drg Date : 11-09-2025
GROUND FLOOR As per A7_staricase & ramp details
(Location : Stairacse)
Drg Title : GVM_A4_DETAILED PLAN
Drg Date : 11-09-2025
1st Level Plan As per A7_staricase & ramp details
(Location : Stairacse)
Drg Title : GVM_A4_DETAILED PLAN
Drg Date : 11-09-2025
2nd Level Plan As per A7_staricase & ramp details
(Location : Stairacse)
Drg Title : GVM_A4_DETAILED PLAN
Drg Date : 11-09-2025
3rd Level Plan As per A7_staricase & ramp details
(Location : Stairacse)
Drg Title : GVM_A4_DETAILED PLAN
Drg Date : 11-09-2025
5.20 MANDANA-01 STAIRCASE FLOORING CODE-A12-04 & 1/A14-01 (LOCATION : Staircase)
3RD Floor As per A7_staricase & ramp details
(Location : Stairacse)
Drg Title : GVM_A4_DETAILED PLAN
Drg Date : 11-09-2025
Exit lobby-ST-J7
Floor Landing 1.0 2.55 1.50 3.83
5.21 MANDANA-01 STAIRCASE-TREADS CODE-A12-04 & 1/A14-01 (LOCATION : Staircase)
3RD Floor As per A7_staricase & ramp details
(Location : Stairacse)
Drg Title : GVM_A4_DETAILED PLAN
Drg Date : 11-09-2025
Exit lobby-ST-J7
5.21 MANDANA-01 STAIRCASE-RISERS CODE-A12-04 & 1/A14-01 (LOCATION : Staircase)
3RD Floor As per A7_staricase & ramp details
(Location : Stairacse)
Drg Title : GVM_A4_DETAILED PLAN
Drg Date : 11-09-2025
Exit lobby-ST-J7
INTERNAL WALL FINISH
6.10 VITRIFIED TILES-2 CLADDING DRG CODE- A12-05 REF : 8/A14-02
Lower Ground Floor
Drg Title : FINISHES DIAGRAM-INT WALLS
Drg No : A12-05
Drg Date : 25-09-2025
Male toilet 1.0 8.82 3.00 26.47
Female toilet 1.0 7.26 3.00 21.77
Drg Title : FINISHES DIAGRAM-INT WALLS
Drg No : A12-05
Drg Date : 25-09-2025
Kitchen toilet 1.0 28.81 3.00 86.44
6.11 GYPSUM / PLASTER + PAINT DRG CODE- A12-05 REF : 10/A14-02
Drg Title : FINISHES DIAGRAM-INT WALLS
Location : Fresh air passage
Drg No : A12-05
Drg Date : 25-09-2025
Fresh air passage (A9-24) 1.0 51.26 4.20 215.30
At Steps 2.0 3.60 avg 3.83 27.54
HVAC shaft Ded of opn -1.0 0.60 1.50 -0.90
DG Shaft Ded of opn -1.0 0.60 1.50 -0.90
Elec Shaft Ded of opn -1.0 0.60 1.50 -0.90
PHE Shaft Ded of opn -1.0 0.60 1.50 -0.90
Staircase nr HVAC tank (A9-26) 1.0 24.69 6.75 166.62
LOWER GROUND FLOOR
Drg Title : FINISHES DIAGRAM-INT WALLS
Location : Fresh air passage
Drg No : A12-05
Drg Date : 25-09-25
Service atrium (A9-24) 1.0 101.91 3.60 366.88
Drg Title : FINISHES DIAGRAM-INT WALLS
Location : Fresh air passage
Drg No : A12-05
Drg Date : 25-09-25
Service Atrium 1.0 57.10 6.90 394.01
Drg Title : FINISHES DIAGRAM-INT WALLS
Location : Fresh air passage
Drg No : A12-05
Drg Date : 25-09-25
Drg Title : FINISHES DIAGRAM-INT WALLS
Location : Fresh air passage
Drg No : A12-05
Drg Date : 25-09-25
Drg Title : FINISHES DIAGRAM-INT WALLS
Location : Fresh air passage
Drg No : A12-05
Drg Date : 25-09-25
Service Passage 1.0 31.80 3.00 95.40
Drg Title : FINISHES DIAGRAM-INT WALLS
Location : Fresh air passage
Drg No : A12-05
Drg Date : 25-09-25
Duct beside terrace 1.0 11.17 5.80 64.80
6.13 SOUND ATTENAUTION DRG CODE- A12-05 REF : 11/A14-02
Drg Title : FINISHES DIAGRAM-INT WALLS
Drg No : A12-05
Drg Date : JUN 20, 2025
Ded Of fresh air passage -1.0 1.45 6.05 -8.77
Ded of stair opn -1.0 1.46 6.05 -8.83
Ded of stair opn -1.0 1.46 4.10 -5.99
Main LT Panel-01 1.0 79.61 Pline 4.10 326.42
rolling shutter -1.0 7.06 4.10 -28.95
Ded Of 2.1m wide passage opn -1.0 1.45 4.10 -5.95
Lower Ground Floor
Drg Title : LOWER GROUND FLOOR
Drg No : A12-05
Drg Date : JUN 20, 2025
Drg Title : GROUND FLOOR
Drg No : A12-05
Drg Date : JUN 20, 2025
AHU room (Sec-A9-06) 1.0 27.57 Pline 4.40 121.29
Drg Title : 1st FLOOR
Drg No : A12-05
Drg Date : JUN 20, 2025
Drg Title : 3rd FLOOR
Drg No : A12-05
Drg Date : JUN 20, 2025
6.14 WHITE GLAZED VITRIFIED TILES CLADDING DRG CODE- A12-05 REF : 8/A14-02
Drg Title : FINISHES DIAGRAM-INT WALLS
Location : HVAC Tank,domestic tank 1 & 2,Raw water tank,fire water tank 1 & 2,eqt,csc,fsc,ww,cto,ts,ct-01,ct-02,tw-01,tw-02
Drg No : A12-05
Drg Date : 25-09-2025
Domestic Water Tank-01 1.0 21.45 4.80 102.96
Domestic Water Tank-02 1.0 21.40 4.80 102.72
Raw Water tank 1.0 14.99 4.80 71.95
Fire Water tank-01 1.0 34.48 4.80 165.50
Fire Water tank-02 1.0 52.09 4.80 250.05
Rain Water tank 1.0 50.30 4.80 241.44
MEZZANINE FLOOR +70.65
(Location : Mez lvl plan +70.65)
Drg Title : GVM_A4_DETAILED PLAN
Drg Date : 11-09-2025
FF Tank 1.0 15.88 P-line 2.40 38.10
Domestic Tank 1.0 12.74 P-line 2.40 30.58
(Location : Mez lvl plan +70.65)
Drg Title : GVM_A4_DETAILED PLAN
Drg Date : 11-09-2025
FF Tank 1.0 16.83 P-line 1.20 20.20
Domestic Tank 1.0 12.52 P-line 1.20 15.02
6.16 PLASTER FINISH DRG CODE- A12-05 REF : 15/A14-02
Drg Title : FINISHES DIAGRAM-INT WALLS
Location : Elev-E-05,Elev-E-04,shafts
Drg No : A12-05
Drg Date : 25-09-2025
Elec Shaft 2.0 0.98 5.10 9.95
Lower Ground Floor
Drg Title : FINISHES DIAGRAM-INT WALLS
Location : Elev-E-05,Elev-E-04,shafts
Drg No : A12-05
Drg Date : 25-09-2025
Av System (A9-25) 1.0 7.56 p-line 8.90 67.27
Ded of lift opn -2.0 1.20 2.10 -5.04
Ded of lift opn -2.0 1.10 2.10 -4.62
Ded of lift opn -1.0 2.80 2.70 -7.56
Elec Shaft 2.0 0.98 6.90 13.46
Drg Title : FINISHES DIAGRAM-INT WALLS
Location : Elev-E-05,Elev-E-04,shafts
Drg No : A12-05
Drg Date : 25-09-2025
Ded of lift opn -2.0 1.20 2.10 -5.04
Ded of lift opn -2.0 1.10 2.10 -4.62
Ded of lift opn -1.0 2.80 2.70 -7.56
Elec Shaft 2.0 0.98 6.90 13.46
Drg Title : FINISHES DIAGRAM-INT WALLS
Location : Elev-E-05,Elev-E-04,shafts
Drg No : A12-05
Drg Date : 25-09-2025
Ded of lift opn -2.0 1.20 2.10 -5.04
Ded of lift opn -2.0 1.10 2.10 -4.62
Ded of lift opn -1.0 2.80 2.70 -7.56
Elec shaft 2.0 0.98 6.90 13.46
Drg Title : FINISHES DIAGRAM-INT WALLS
Location : Elev-E-05,Elev-E-04,shafts
Drg No : A12-05
Drg Date : 25-09-2025
Ded of lift opn -2.0 1.20 2.10 -5.04
Ded of lift opn -2.0 1.10 2.10 -4.62
Ded of lift opn -1.0 2.80 2.70 -7.56
Drg Title : FINISHES DIAGRAM-INT WALLS
Location : Elev-E-05,Elev-E-04,shafts
Drg No : A12-05
Drg Date : 25-09-2025
Ded of lift opn -1.0 1.10 2.10 -2.31
Elec Shaft 2.0 0.98 5.10 9.95
Drg Title : FINISHES DIAGRAM-INT WALLS
Location : Elev-E-05,Elev-E-04,shafts
Drg No : A12-05
Drg Date : 25-09-2025
Ded of lift opn -1.0 1.10 2.10 -2.31
6 SKIRTING WORK
6.1 WOODEN SKIRTING CODE-A12-06 & 3/A14-03
Lower ground Floor
(Location : Sidhi Gallery)
Drg Title : 2025-09-18_GVM_A12-06-FINISH DIAGRAM INTERIOR BASE
Drg Date : 18-09-2025
Siddhi Gallery 1.0 92.12 P-Line 92.12
Ded Of opn -1.0 2.86 -2.86
Ded Of Lobby Opn -1.0 5.95 P-Line -5.95
Ded Of rolling Shutter -1.0 4.75 -4.75
Ded Of Fire Door -1.0 1.20 -1.20
Siddhi Gallery 1.0 154.30 P-Line 154.30
Ded Of rolling Shutter -1.0 4.75 -4.75
(Location : Sidhi Gallery)
Drg Title : 2025-09-18_GVM_A12-06-FINISH DIAGRAM INTERIOR BASE
Drg Date : 18-09-2025
Siddhi Gallery 1.0 178.10 P-Line 178.10
Ded OF Opn -2.0 12.57 P-Line -25.15
Ded Of opn -1.0 1.36 -1.36
Ded Of opn -1.0 1.20 -1.20
Ded Of lobby Opn -2.0 1.50 -3.00
On Column 7.0 2.55 17.84
Lobby Area 2.0 1.74 3.47
(Location : Sidhi Gallery)
Drg Title : 2025-09-18_GVM_A12-06-FINISH DIAGRAM INTERIOR BASE
Drg Date : 18-09-2025
Sidhi Gallery 1.0 178.10 P-Line 178.10
Ded Of Opn -1.0 1.36 -1.36
Ded Of Lobby Entry -2.0 1.50 -3.00
On Column 5.0 2.55 12.75
(Location : Sidhi Gallery)
Drg Title : 2025-09-18_GVM_A12-06-FINISH DIAGRAM INTERIOR BASE
Drg Date : 18-09-2025
Sidhi Gallery 1.0 127.82 P-Line 127.82
Ded Of lobby Entry -2.0 1.50 -3.00
Ded Of Entry -1.0 1.80 -1.80
Ded Of entry -1.0 1.36 -1.36
on Column 5.0 2.55 12.75
6.2 KOTA STONE SKIRTING (LOADING BAY) CODE-A12-06 & 2/A14-03
(Location : Male Toilet,Female Toilet, 1.2m Wide passage)
Drg Title : 2025-09-18_GVM_A12-06-FINISH DIAGRAM INTERIOR BASE
Drg Date : 18-09-2025
6.3 KOTA STONE SKIRTING CODE-A12-06 & 1/A14-03
(Location : Fresh air Passage,DG Area,Pump Room,LT Panel area,2.1m wide Passage)
Drg Title : 2025-09-18_GVM_A12-06-FINISH DIAGRAM INTERIOR BASE
Drg Date : 18-09-2025
Fresh air Passage 1.0 51.26 P-Line 51.26
Ded Of Opn -1.0 4.53 P-Line -4.53
Ded Of Opn -1.0 1.50 P-Line -1.50
DG Area 1.0 82.53 P-Line 82.53
Ded Of Opn -2.0 1.50 P-Line -3.00
Ded Of Opn -2.0 4.00 P-Line -8.00
DG Area 1.0 43.49 P-Line 43.49
Ded Of Opn -1.0 4.00 P-Line -4.00
Ded Of Opn -1.0 1.46 P-Line -1.46
LT Panel Area 1.0 83.68 P-Line 83.68
Ded Of Opn -1.0 4.00 P-Line -4.00
Ded Of Opn -1.0 1.50 P-Line -1.50
Pump Room 1.0 90.63 P-Line 90.63
Ded Of opn -1.0 7.26 P-Line -7.26
2.1 m Wide Passage 1.0 129.11 P-Line 129.11
Ded Of HVAC -1.0 0.70 -0.70
Ded Of Dg Shaft -1.0 2.05 -2.05
Ded Of Elec Shaft -1.0 2.05 -2.05
Ded Of PHE Shaft -1.0 1.63 -1.63
Ded OF Elev Duct -1.0 2.85 -2.85
Ded Of Elev-e-04 -1.0 1.15 -1.15
Pump Room 1.0 33.64 P-Line 33.64
Lower ground Floor
(Location : AHU,Service Atrium)
Drg Title : 2025-09-18_GVM_A12-06-FINISH DIAGRAM INTERIOR BASE
Drg Date : 18-09-2025
AHU 1.0 28.90 P-Line 28.90
Service atrium 1.0 97.53 P-Line 97.53
Ded Of Opn -1.0 1.20 -1.20
Ded Of Opn -1.0 2.70 -2.70
Ded OF Shaft -4.0 0.60 -2.40
(Location : BOH Lobby,AHU)
Drg Title : 2025-09-18_GVM_A12-06-FINISH DIAGRAM INTERIOR BASE
Drg Date : 18-09-2025
Boh Lobby 1.0 27.85 P-Line 27.85
Ded Of Lift Opn -1.0 1.13 -1.13
Ded Of Lift Opn -1.0 2.85 -2.85
Service passage -1.0 5.20 -5.20
(Location : BOH Lobby,AHU)
Drg Title : 2025-09-18_GVM_A12-06-FINISH DIAGRAM INTERIOR BASE
Drg Date : 18-09-2025
Boh Lobby 1.0 27.96 P-Line 27.96
Ded Of Lift Opn -1.0 1.13 -1.13
Ded Of Lift Opn -1.0 2.85 -2.85
Service passage -1.0 5.20 -5.20
(Location : BOH Lobby)
Drg Title : 2025-09-18_GVM_A12-06-FINISH DIAGRAM INTERIOR BASE
Drg Date : 18-09-2025
BOH Lobby 1.0 29.67 29.67
Ded Of lift Wall -1.0 6.40 -6.40
Ded Of lift Wall -1.0 3.62 -3.62
(Location : AHU,Service passage)
Drg Title : 2025-09-18_GVM_A12-06-FINISH DIAGRAM INTERIOR BASE
Drg Date : 18-09-2025
AHU 1.0 40.87 P-line 40.87
Service passage 1.0 16.01 16.01
(Location : Service terrace)
Drg Title : 2025-09-18_GVM_A12-06-FINISH DIAGRAM INTERIOR BASE
Drg Date : 18-09-2025
Service terrace 1.0 38.51 P-line 38.51
Ded Of Duct Wall -1.0 6.98 -6.98
6.4 S.S BASE (COLUMN) CODE-A12-06 & 4/A14-03
(Location : 7.2m public Corridor)
Drg Title : 2025-09-18_GVM_A12-06-FINISH DIAGRAM INTERIOR BASE
Drg Date : 18-09-2025
7.2m public Corridor 3.0 3.61 10.84
5.23 25MM THICK KOTA STONE-SKIRTING CODE-A12-04 & 4/A14-01 (LOCATION : Staircase)
Basement Floor As per A7_staricase & ramp details
(Location : Stairacse)
Drg Title : GVM_A4_DETAILED PLAN
Drg Date : 11-09-2025
Floor Landing 1.0 19.70 P-line 19.70
Mid-landing 2.0 6.48 P-line 12.96
Floor Landing 1.0 30.20 P-line 30.20
Mid-landing-1 & 3 2.0 2.00 4.00
Mid-landing-2 1.0 8.79 P-line 8.79
Lower Ground Level Plan As per A7_staricase & ramp details
(Location : Stairacse)
Drg Title : GVM_A4_DETAILED PLAN
Drg Date : 11-09-2025
Floor Landing-01 (-9900mm) 1.0 25.32 P-line 25.32
Mid-landing-2 (-8250mm) 1.0 8.39 P-line 8.39
Mid-landing-3 (-6450mm) 1.0 8.75 P-line 8.75
Mid-landing-4 (-4800mm) 1.0 8.75 P-line 8.75
Floor Landing-01 (-9900 mm) 1.0 14.46 P-line 14.46
Floor Landing-02 (-8100 mm) 1.0 20.92 P-line 20.92
Mid-landing-3 (-6450 mm) 1.0 8.75 P-line 8.75
Mid-landing-4 (-4650 mm ) 1.0 8.75 P-line 8.75
Floor Landing-4 1.0 4.30 2.00 8.60
Mid-landing-5 & 7 2.0 2.00 4.00
Mid-landing-6 1.0 9.10 P-line 9.10
Floor Landing-8 1.0 9.50 P-line 9.50
Mid-landing-9 1.0 2.00 2.00
Floor Landing-10 1.0 9.10 P-line 9.10
Mid-landing-11 frm detailed plan 2.0 5.58 11.15
Floor Landing 1.0 6.67 P-line 6.67
Ground Level Plan As per A7_staricase & ramp details
(Location : Stairacse)
Drg Title : GVM_A4_DETAILED PLAN
Drg Date : 11-09-2025
Floor Landing-05 (-3000mm) 1.0 10.98 P-line 10.98
Mid-landing-6 (-1350mm) 1.0 8.75 P-line 8.75
Mid-landing-7 (+450mm) 1.0 8.75 P-line 8.75
Mid-landing-8 (+2100mm) 1.0 8.75 P-line 8.75
Floor Landing-(-3000mm) 1.0 10.35 P-line 10.35
Mid-landing-6 (-1200mm) 1.0 8.75 P-line 8.75
Mid-landing-7 (+450mm) 1.0 9.35 P-line 9.35
Mid-landing-8 (+2250mm) 1.0 8.75 P-line 8.75
1st Level Plan As per A7_staricase & ramp details
(Location : Stairacse)
Drg Title : GVM_A4_DETAILED PLAN
Drg Date : 11-09-2025
Floor Landing-09 (3900mm) 1.0 10.98 P-line 10.98
Mid-landing-10 (+5550mm) 1.0 8.75 P-line 8.75
Mid-landing-11 (+7350mm) 1.0 8.75 P-line 8.75
Mid-landing-12 (+9000mm) 1.0 8.75 P-line 8.75
Floor Landing-(+3900mm) 1.0 10.26 P-line 10.26
Mid-landing-10 (+5700mm) 1.0 8.75 P-line 8.75
Mid-landing-11 (+7350mm) 1.0 8.75 P-line 8.75
Mid-landing-12 (+9150mm) 1.0 8.75 P-line 8.75
2nd Level Plan As per A7_staricase & ramp details
(Location : Stairacse)
Drg Title : GVM_A4_DETAILED PLAN
Drg Date : 11-09-2025
Floor Landing-013 (10800mm) 1.0 10.98 P-line 10.98
Mid-landing-14 (+12450mm) 1.0 8.75 P-line 8.75
Mid-landing-15 (+14250mm) 1.0 8.75 P-line 8.75
Floor Landing-(+10800mm) 1.0 13.95 P-line 13.95
Mid-landing-14 (+12450mm) 1.0 9.34 P-line 9.34
Mid-landing-15 (+14250mm) 1.0 8.75 P-line 8.75
3rd Level Plan As per A7_staricase & ramp details
(Location : Stairacse)
Drg Title : GVM_A4_DETAILED PLAN
Drg Date : 11-09-2025
Floor Landing-016 (15900mm) 1.0 10.98 P-line 10.98
Mid-landing-17 (+17550mm) 1.0 8.75 P-line 8.75
Mid-landing-18 (+19350mm) 1.0 8.75 P-line 8.75
Floor Landing-(+15900mm) 1.0 9.75 P-line 9.75
Mid-landing-17 (+17550mm) 1.0 10.84 P-line 10.84
Mid-landing-18 (+19350mm) 1.0 8.75 P-line 8.75
Floor Landing-(+20400mm) 1.0 18.88 P-line 18.88
4th Level Plan As per A7_staricase & ramp details
(Location : Stairacse)
Drg Title : GVM_A4_DETAILED PLAN
Drg Date : 11-09-2025
Floor Landing-019 (15900mm) 1.0 7.20 P-line 7.20
5.24 25MM THICK KOTA STONE-INCLINED SKIRTING CODE-A12-04 & 4/A14-01 (LOCATION : Staircase)
(Location : Stairacse)
Drg Title : GVM_A4_DETAILED PLAN
Drg Date : 11-09-2025
DG-Area 2 staircse 12.0 4.09 49.13
Fresh air passsage 12.0 4.09 49.13
LOWER GROUND FLOOR As per A7_staricase & ramp details
(Location : Stairacse)
Drg Title : GVM_A4_DETAILED PLAN
Drg Date : 11-09-2025
GROUND FLOOR As per A7_staricase & ramp details
(Location : Stairacse)
Drg Title : GVM_A4_DETAILED PLAN
Drg Date : 11-09-2025
1st Level Plan As per A7_staricase & ramp details
(Location : Stairacse)
Drg Title : GVM_A4_DETAILED PLAN
Drg Date : 11-09-2025
2nd Level Plan As per A7_staricase & ramp details
(Location : Stairacse)
Drg Title : GVM_A4_DETAILED PLAN
Drg Date : 11-09-2025
3rd Level Plan As per A7_staricase & ramp details
(Location : Stairacse)
Drg Title : GVM_A4_DETAILED PLAN
Drg Date : 11-09-2025
5.23 MANDANA-01 STAIRCASE SKIRTING CODE-A12-04 & 1/A14-01 (LOCATION : Staircase)
3rd Floor As per A7_staricase & ramp details
(Location : Stairacse)
Drg Title : GVM_A4_DETAILED PLAN
Drg Date : 11-09-2025
Mid landing 1.0 1.50 1.50
Less door -1.0 1.50 -1.50
5.24 MANDANA-01 STAIRCASE INCLINED SKIRTING CODE-A12-04 & 1/A14-01 (LOCATION : Staircase)
(Location : Stairacse)
Drg Title : GVM_A4_DETAILED PLAN
Drg Date : 11-09-2025
8 FALSE CEILING WORK
8.9 MINERAL FIBRE GRID CEILING 600X600 CODE-A12-07 & 2/A14-04
LOWER GROUND LEVEL PLAN
(Location : Service Atrium)
Drg Title : GVM_A12_07_Int Ceiling Diagram
Drg Date : 18-09-2025
Service Atrium 1.0 81.27 P-area 81.27
Service Atrium 1.0 22.81 P-area 22.81
GROUND FLOOR LEVEL PLAN
(Location : BOH LOBBY)
Drg Title : GVM_A12_07_Int Ceiling Diagram
Drg Date : 18-09-2025
Boh Lobby 1.0 37.81 P-area 37.81
1ST FLOOR LEVEL PLAN
(Location : BOH LOBBY)
Drg Title : GVM_A12_07_Int Ceiling Diagram
Drg Date : 18-09-2025
Boh Lobby 1.0 38.08 P-area 38.08
2ND FLOOR LEVEL PLAN
(Location : BOH LOBBY)
Drg Title : GVM_A12_07_Int Ceiling Diagram
Drg Date : 18-09-2025
Boh Lobby 1.0 43.42 P-area 43.42
3RD FLOOR LEVEL PLAN
(Location : BOH LOBBY)
Drg Title : GVM_A12_07_Int Ceiling Diagram
Drg Date : 18-09-2025
ST-E-01 Entry 1.0 12.03 P-area 12.03
8.10 GYPSUM + PAINT CODE-A12-07 & 5/A14-04
LOWER GROUND FLOOR LEVEL PLAN
(Location : M Toilet,F Toilet)
Drg Title : GVM_A12_07_Int Ceiling Diagram
Drg No : A12-07
Drg Date : 18-09-2025
M-Toilet 1.0 27.39 P-area 27.39
F-Toilet 1.0 48.78 P-area 48.78
GROUND FLOOR LEVEL PLAN
(Location : M Toilet,F Toilet,Baby Care,Green Room)
Drg Title : GVM_A12_07_Int Ceiling Diagram
Drg Date : 18-09-2025
M-Toilet 1.0 23.81 P-area 23.81
F-Toilet 1.0 32.17 P-area 32.17
Green Room 1.0 4.80 4.03 19.32
1ST FLOOR LEVEL PLAN
(Location : M Toilet,F Toilet,Baby Care)
Drg Title : GVM_A12_07_Int Ceiling Diagram
Drg Date : 18-09-2025
M-Toilet 1.0 23.19 P-area 23.19
F-Toilet 1.0 22.56 P-area 22.56
M-Toilet 1.0 16.95 P-area 16.95
F-Toilet 1.0 16.50 P-area 16.50
Janitor 1.0 3.01 P-area 3.01
2ND FLOOR LEVEL PLAN
(Location : M Toilet,F Toilet,Baby Care)
Drg Title : GVM_A12_07_Int Ceiling Diagram
Drg Date : 18-09-2025
F-Toilet 1.0 8.47 P-area 8.47
Toilet 1.0 2.85 P-area 2.85
4TH FLOOR LEVEL PLAN
(Location : M Toilet,F Toilet)
Drg Title : GVM_A12_07_Int Ceiling Diagram
Drg Date : 18-09-2025
F-Toilet 1.0 27.11 P-area 27.11
M-Toilet 1.0 35.87 P-area 35.87
8.11 PLASTER FINISH CODE-A12-07
3rd FLOOR LEVEL PLAN
(Location : Service passage)
Drg Title : GVM_A12_07_Int Ceiling Diagram
Drg Date : 18-09-2025
service passage 1.0 7.73 P-area 7.73
8.12 METAL CEILING CODE-A12-07 & 11/A14-04
4TH FLOOR LEVEL PLAN
(Location : kitchen , bakery)
Drg Title : GVM_A12_07_Int Ceiling Diagram
Drg Date : 18-09-2025
Kitchen 1.0 60.88 P-area 60.88
Bakery 1.0 27.16 P-area 27.16
8.13 PLASTER + PAINT CODE-A12-07 & 5/A14-04
BASEMENT FLOOR LEVEL PLAN
(Location :2.1 m Passage,EQT,CSE,FSE,WW,ISZ,TS,CTO,SSZ,CT-1,CT-2,TW-1,TW-2)
Drg Title : GVM_A12_07_Int Ceiling Diagram
Drg Date : 18-09-2025
2.1m Wide Passage 1.0 200.08 P-area 200.08
Domestic tank-01 & 02 1.0 42.87 P-area 42.87
Raw Water Tank 1.0 13.90 P-area 13.90
Fire Water Tank 1.0 154.35 P-area 154.35
3RD FLOOR LEVEL PLAN
(Location : ELEV-J5)
Drg Title : GVM_A12_07_Int Ceiling Diagram
Drg Date : 18-09-2025
4TH FLOOR LEVEL PLAN
(Location :Janitor)
Drg Title : GVM_A12_07_Int Ceiling Diagram
Drg Date : 18-09-2025
Janitor 1.0 1.94 P-area 1.94
8.14 SOUND ATTENUATION CODE-A12-07 & 8/A14-04
BASEMENT FLOOR LEVEL PLAN
(Location : Pump Room,Fresh Air passage,DG Area,LT Panel Area)
Drg Title : GVM_A12_07_Int Ceiling Diagram
Drg Date : 18-09-2025
DG Area-2 1.0 232.85 P-area 232.85
Fresh Air 1.0 72.20 P-area 72.20
Pump Rm 1.0 227.23 P-area 227.23
DG Area 1.0 89.91 P-area 89.91
LT Panel Area 1.0 197.96 P-area 197.96
PUMP Rm 1.0 55.37 P-area 55.37
LOWER GROUND LEVEL PLAN
(Location : AHU Rm)
Drg Title : GVM_A12_07_Int Ceiling Diagram
Drg Date : 18-09-2025
AHU Rm 1.0 20.81 P-area 20.81
AHU Rm 1.0 41.72 P-area 41.72
GROUND FLOOR LEVEL PLAN
(Location : AHU Rm)
Drg Title : GVM_A12_07_Int Ceiling Diagram
Drg Date : 18-09-2025
AHU Rm 1.0 55.32 P-area 55.32
1ST FLOOR LEVEL PLAN
(Location : AHU)
Drg Title : GVM_A12_07_Int Ceiling Diagram
Drg Date : 18-09-2025
AHU 1.0 99.90 P-area 99.90
3RD FLOOR LEVEL PLAN
(Location : AHU)
Drg Title : GVM_A12_07_Int Ceiling Diagram
Drg Date : 18-09-2025
AHU 1.0 74.64 P-area 74.64
AHU 1.0 30.70 P-area 30.70
AHU 1.0 23.75 P-area 23.75
8.15 M.R GRADE GYPSUM GRID 600X600 CODE-A12-07 & 7/A14-04
LOWER GROUND LEVEL PLAN
(Location : M-toilet,F-toilet)
Drg Title : GVM_A12_07_Int Ceiling Diagram
Drg Date : 18-09-2025
Male Toilet 1.0 4.66 P-area 4.66
Female Toilet 1.0 3.19 P-area 3.19
4TH FLOOR LEVEL PLAN
(Location : Toilet)
Drg Title : GVM_A12_07_Int Ceiling Diagram
Drg Date : 18-09-2025
Toilet 1.0 3.90 P-area 3.90
9 PARAPET FINISH
9.2 1SIDE STONE CLADDING CODE-A11-01 & 1/A11-01
LOWER GROUND FLOOR LVL PLAN
(Location :ELIPTICAL )
Drg Title : 2025-09-18_GVM_A12-08,09-EXT ROOF ,COPING LVL DIAGRAM
Drg No : A12-08,09
Drg Date : 19-09-2025
Sandstone coping 1.0 49.47 P-area 49.47
13 WATERPROOFING WORK
13.1 LOCATION : TOILET
LOWER GROUND FLOOR
(Location : ELIPTICAL MALE & FEMALE TOILET)
Drg Title : 2025-09-18_GVM_A0-12_SUNK DIAGRAM
Drg Date : 19-09-2025
Female Toilet 1.0 41.24 P-area 41.24
J.store 1.0 2.63 P-area 2.63
baby care 1.0 5.17 P-area 5.17
Male Toilet 1.0 27.60 P-area 27.60
Passage 1.0 5.94 P-area 5.94
Passage 1.0 11.54 P-area 11.54
Female Toilet 1.0 3.22 P-area 3.22
Male Toilet 1.0 4.88 P-area 4.88
Passage 1.0 2.82 P-area 2.82
Female Toilet 1.0 35.19 P-line 1.00 35.19
J.store 1.0 6.90 P-area 1.00 6.90
baby care 1.0 9.46 P-area 1.00 9.46
Male Toilet 1.0 28.58 P-line 1.00 28.58
Passage 1.0 12.24 P-line 1.00 12.24
Passage 1.0 14.09 P-line 1.00 14.09
Female Toilet 1.0 7.26 P-line 1.00 7.26
Male Toilet 1.0 9.36 P-line 1.00 9.36
Passage 1.0 7.06 P-line 1.00 7.06
(Location : ELIPTICAL MALE & FEMALE TOILET)
Drg Title : 2025-09-18_GVM_A0-12_SUNK DIAGRAM
Drg Date : 19-09-2025
Female Toilet 1.0 32.42 P-area 32.42
J.store 1.0 1.75 P-area 1.75
Baby Care 1.0 5.16 P-area 5.16
Male Toilet 1.0 24.01 P-area 24.01
Passage 1.0 5.83 P-area 5.83
Passage 1.0 11.54 P-area 11.54
Female Toilet 1.0 31.24 P-line 1.00 31.24
Janitor Store 1.0 5.30 P-line 1.00 5.30
Baby Care 1.0 9.45 P-line 1.00 9.45
Male Toilet 1.0 25.52 P-line 1.00 25.52
Passage 1.0 11.97 P-line 1.00 11.97
Passage 1.0 14.11 P-line 1.00 14.11
15.3 WALL MOUNTED S.S RAIL CODE-A12-12 & 01/A7-22
Floor landing 1.0 7.46 Pline 7.46
Mid landing 1.0 6.25 Pline 6.25
Flight-1 & 2 (both side) 4.0 3.42 13.70
LOWER GROUND FLOOR
Floor landing 1.0 7.46 Pline 7.46
Mid landing 1.0 6.25 Pline 6.25
Flight-1 & 2 (both side) 4.0 3.42 13.70
Floor landing 1.0 5.14 5.14
Flight-1 (both sides) 2.0 3.76 7.52
Mid landing 1.0 0.32 0.32
Flight-2 & 3 (both sides) 4.0 3.76 15.04
Mid landing 1.0 0.32 0.32
Floor landing 1.0 3.19 3.19
Flight-1 & 2 (both sides) 4.0 3.76 15.04
Mid landing 1.0 1.99 1.99
MEZZANINE FLOOR
Floor landing 1.0 7.39 7.39
Flight-1 (both sides) 2.0 2.42 4.84
15.13 GRANITE COUNTER
Lower ground floor
(Location : ELIPTICAL )
Drg Title : 2025-09-18_GVM_A12-12-RAILING DIAGRAM
Drg Date : 19-09-2025
FACIA - GRANITE
(Location : ELIPTICAL )
Drg Title : 2025-09-18_GVM_A12-12-RAILING DIAGRAM
Drg Date : 19-09-2025
(Location : ELIPTICAL )
Drg Title : 2025-09-18_GVM_A12-12-RAILING DIAGRAM
Drg Date : 19-09-2025
Toilet , 8.0 8.00
GRANITE COUNTER
(Location : ELIPTICAL )
Drg Title : 2025-09-18_GVM_A12-12-RAILING DIAGRAM
Drg Date : 19-09-2025
FACIA - GRANITE
(Location : ELIPTICAL )
Drg Title : 2025-09-18_GVM_A12-12-RAILING DIAGRAM
Drg Date : 19-09-2025
(Location : ELIPTICAL )
Drg Title : 2025-09-18_GVM_A12-12-RAILING DIAGRAM
Drg Date : 19-09-2025
Toilet , 5.0 5.00
GRANITE COUNTER
(Location : ELIPTICAL )
Drg Title : 2025-09-18_GVM_A12-12-RAILING DIAGRAM
Drg Date : 19-09-2025
FACIA - GRANITE
(Location : ELIPTICAL )
Drg Title : 2025-09-18_GVM_A12-12-RAILING DIAGRAM
Drg Date : 19-09-2025
(Location : ELIPTICAL )
Drg Title : 2025-09-18_GVM_A12-12-RAILING DIAGRAM
Drg Date : 19-09-2025
Toilet , 8.0 8.00
GRANITE COUNTER
(Location : ELIPTICAL )
Drg Title : 2025-09-18_GVM_A12-12-RAILING DIAGRAM
Drg Date : 19-09-2025
FACIA - GRANITE
(Location : ELIPTICAL )
Drg Title : 2025-09-18_GVM_A12-12-RAILING DIAGRAM
Drg Date : 19-09-2025
(Location : ELIPTICAL )
Drg Title : 2025-09-18_GVM_A12-12-RAILING DIAGRAM
Drg Date : 19-09-2025
Toilet , 5.0 5.00
LOWER GROUND FLOOR
(Location : ELIPTICAL )
Drg Title : GVM_A4_DETAILES PLAN_10-09-25
Drg Date : 19-09-2025
L-Shape 3.0 3.00
L-Shape 5.0 5.00
(Location : ELIPTICAL )
Drg Title : GVM_A4_DETAILES PLAN_10-09-25
Drg Date : 19-09-2025
L-Shape 2.0 2.00
L-Shape 4.0 4.00
(Location : ELIPTICAL )
Drg Title : GVM_A4_DETAILES PLAN_10-09-25
Drg Date : 19-09-2025
L-Shape 2.0 2.00
L-Shape 2.0 2.00
(Location : ELIPTICAL )
Drg Title : GVM_A4_DETAILES PLAN_10-09-25
Drg Date : 19-09-2025
L-Shape 1.0 1.00
(Location : ELIPTICAL )
Drg Title : GVM_A4_DETAILES PLAN_10-09-25
Drg Date : 19-09-2025
L-Shape 2.0 2.00
L-Shape 2.0 2.00
LOWER GROUND FLOOR
(Location : ELIPTICAL )
Drg Title : GVM_A4_DETAILES PLAN_10-09-25
Drg Date : 19-09-2025
I-Shape 1.0 1.00
I-Shape 1.0 1.00
(Location : ELIPTICAL )
Drg Title : GVM_A4_DETAILES PLAN_10-09-25
Drg Date : 19-09-2025
I-Shape 1.0 1.00
I-Shape 1.0 1.00
(Location : ELIPTICAL )
Drg Title : GVM_A4_DETAILES PLAN_10-09-25
Drg Date : 19-09-2025
I-Shape 1.0 1.00
I-Shape 1.0 1.00
(Location : ELIPTICAL )
Drg Title : GVM_A4_DETAILES PLAN_10-09-25
Drg Date : 19-09-2025
I-Shape 1.0 1.00
(Location : ELIPTICAL )
Drg Title : GVM_A4_DETAILES PLAN_10-09-25
Drg Date : 19-09-2025
I-Shape 1.0 1.00
I-Shape 1.0 1.00
URINAL PARTITION
LOWER GROUND FLOOR
(Location : ELIPTICAL )
Drg Title : GVM_A4_DETAILES PLAN_10-09-25
Drg Date : 19-09-2025
(Location : ELIPTICAL )
Drg Title : GVM_A4_DETAILES PLAN_10-09-25
Drg Date : 19-09-2025
(Location : ELIPTICAL )
Drg Title : GVM_A4_DETAILES PLAN_10-09-25
Drg Date : 19-09-2025
9 PARAPET FINISH
9 PARAPET FINISH
9.1 2 SIDE PLASTER
Drg Title : 2025-09-18_GVM_A12-08,09-EXT ROOF ,COPING LVL DIAGRAM
Drg Date : 19-09-2025
9.2 1 SIDE STONE CLADDING
LOWER GROUND FLOOR
(Location : ELIPTICAL )
Drg Title : 2025-09-18_GVM_A12-08,09-EXT ROOF ,COPING LVL DIAGRAM
Drg Date : 19-09-2025
Elliptical building 1.0 151.80 0.49 74.38
Drg Title : 2025-09-18_GVM_A12-08,09-EXT ROOF ,COPING LVL DIAGRAM
Drg Date : 19-09-2025
9.4 2 SIDE STONE CLADDING
(Location : ELIPTICAL )
Drg Title : 2025-09-18_GVM_A12-08,09-EXT ROOF ,COPING LVL DIAGRAM
Drg Date : 19-09-2025
Elliptical building 2.0 121.56 1.13 274.73
Elliptical building 2.0 18.96 1.13 42.84
Elliptical building 2.0 22.74 1.13 51.40
Elliptical building 2.0 35.34 1.13 79.87
Elliptical building 4.0 1.25 1.13 5.65
Elliptical building 2.0 2.56 1.13 5.78
10 FLASHING TYPE
10.1 FLASHING TYPE 1 CODE-A11-01 & 5/A11-01
Flashing Width =.350
Drg Title : 2025-09-18_GVM_A12-08,09-EXT ROOF ,COPING LVL DIAGRAM
Drg Date : 19-09-2025
North building 1.0 40.25 0.49 19.72
10.3 FLASHING TYPE 3 CODE-A11-01 & 7/A11-01
Drg Title : 2025-09-18_GVM_A12-08,09-EXT ROOF ,COPING LVL DIAGRAM
Drg Date : 19-09-2025
E Building 1.0 38.24 38.24
North Building 1.0 13.04 13.04
North Building 2.0 7.18 14.35
North Building 1.0 10.54 10.54
North Building 1.0 11.44 11.44
North Building 1.0 5.80 5.80
North Building 1.0 5.23 5.23
North Building 1.0 16.23 16.23
North Building 1.0 9.76 9.76
11 ROOF LEVEL FINISH
11.1 LOOSE GRAVEL STONE CODE-A12-09 & 15/A14-01
Drg Title : 2025-09-18_GVM_A12-08,09-EXT ROOF ,COPING LVL DIAGRAM
Drg Date : 19-09-2025
Loose gravel stone 1.0 361.00 361.00
Drg Title : 2025-09-18_GVM_A12-08,09-EXT ROOF ,COPING LVL DIAGRAM
Drg Date : 19-09-2025
Loose gravel stone 1.0 13.74 13.74
11.2 GREEN ROOF CODE-A12-09 & 15/A14-01
Drg Title : 2025-09-18_GVM_A12-08,09-EXT ROOF ,COPING LVL DIAGRAM
Drg Date : 19-09-2025
Green roof 1.0 41.44 41.44
11.4 ZINC ROOFING CODE-A12-09 & 15/A14-01
Drg Title : 2025-09-18_GVM_A12-08,09-EXT ROOF ,COPING LVL DIAGRAM
Drg Date : 19-09-2025
Eliptical roof 1.0 236.64 236.64
11.5 KOTA STONE CODE-A12-09 & 4/A14-01
LOWER GROUND FLOOR
Drg Title : 2025-09-18_GVM_A12-08,09-EXT ROOF ,COPING LVL DIAGRAM
Drg Date : 19-09-2025
ELIPTICAL OUTSIDE FLOORING 1.0 847.79 847.79
Drg Title : 2025-09-18_GVM_A12-08,09-EXT ROOF ,COPING LVL DIAGRAM
Drg Date : 19-09-2025
Eliptical roof 1.0 236.64 236.64
12 DRAINAGE WALL FINISH (A12-11)
12.1 STONE WALL-LAWN DRAIN CODE-A12-11 & 1/A11-02
Drg Title : 2025-09-18_GVM_A12-11-DRAINAGE DIAGRAM
Drg Date : 19-09-2025
At outside eliptical area 1.0 8.09 8.09
12.2 STONE WALL-STONE FLOOR DRAIN CODE-A12-11 & 2/A11-02
LOWER GROUND FLOOR
Drg Title : 2025-09-18_GVM_A12-11-DRAINAGE DIAGRAM
Drg Date : 19-09-2025
At outside eliptical area 1.0 144.85 144.85
Drg Title : 2025-09-18_GVM_A12-11-DRAINAGE DIAGRAM
Drg Date : 19-09-2025
At outside eliptical area 1.0 11.56 11.56
12.4 STONE WALL - STONE FLOOR (WITHOUT PEBBLE) DRAIN CODE-A12-11 & 4/A11-02
Drg Title : 2025-09-18_GVM_A12-11-DRAINAGE DIAGRAM
Drg Date : 19-09-2025
Eliptical service ramp 2.0 2.62 5.24
12.5 STONE FLOOR - STONE FLOOR DRAIN CODE-A12-11 & 5/A11-02
Drg Title : 2025-09-18_GVM_A12-11-DRAINAGE DIAGRAM
Drg Date : 19-09-2025
4M wide opening area 3.0 5.03 15.08
Drg Title : 2025-09-18_GVM_A12-11-DRAINAGE DIAGRAM
Drg Date : 19-09-2025
At outside eliptical area 1.0 1.65 1.65
Drg Title : 2025-09-18_GVM_A12-11-DRAINAGE DIAGRAM
Drg Date : 19-09-2025
12.7 STONE WALL - ROAD DRAIN CODE-A12-11 & 7/A11-02
Drg Title : 2025-09-18_GVM_A12-11-DRAINAGE DIAGRAM
Drg Date : 19-09-2025
4M wide opening area 2.0 3.99 7.98
13 WATERPROOFING BELOW GROUND LEVEL
13.1 1.2 mm HDPE MEMBRANE PRESSURE SENSITIVE ADHESIVE (Below Footing)
Drg Title : A12-14A,B,C- WATERPROOFING DIAGRAM
Drg Date : 01-04-2026
J1A, J1B, J2A, J2B, J3A, J3B, J4A, J4B, J5A, J5B,J6A, J6B, J7A, J7B, J8A, J8B, J9A, J9B,J10A, J10B, J11A, J11B, J12A, J12B, J13A, J13B,J14A, J14B, J15A, J15B, J16A, J16B, J17A, J17B,J18A, J18B, J19A, J19B, J20A, J20B, J21A, J21B 21.0 3.90 8.40 1.35 1385.37
HVAC TANK 1.0 43.21 P-AREA 1.35 43.21
13.2 1.2MM CROSS LAMINATED SBS MODIFIED MEMBRANE + 8MM THK HDPE PROTECTION BOARD
Drg Title : A12-14A,B,C- WATERPROOFING DIAGRAM
Drg Date : 01-04-2026
J1A, J1B, J2A, J2B, J3A, J3B, J4A, J4B, J5A, J5B,J6A, J6B, J7A, J7B, J8A, J8B, J9A, J9B,J10A, J10B, J11A, J11B, J12A, J12B, J13A, J13B,J14A, J14B, J15A, J15B, J16A, J16B, J17A, J17B,J18A, J18B, J19A, J19B, J20A, J20B, J21A, J21B 21.0 3.90 8.40 1.35 687.96
DOMESTIC TANK 02 1.0 3.90 9.90 1.35 3.90
HVAC TANK 1.0 43.21 P-AREA 1.35 43.21
13.3 1.2 mm HDPE MEMBRANE PRESSURE SENSITIVE ADHESIVE (below grade slab)
Drg Title : A12-14A,B,C- WATERPROOFING DIAGRAM
Drg Date : 01-04-2026
BLOCK J 1.0 2633.75 P-area 2633.75
13.3 1.2 mm HDPE MEMBRANE PRESSURE SENSITIVE ADHESIVE (below grade slab)
Drg Title : A12-14A,B,C- WATERPROOFING DIAGRAM
Drg Date : 01-04-2026
14 ELIPTICAL AREA
LOWER GROUND FLOOR
Drg Title : 2025-09-18_GVM_A4.ELIPTICAL AREA
Drg Date : 01-04-2026
Lower ground floor 1.0 2120.64 P-area 2120.64
14 ELIPTICAL volume
LOWER GROUND FLOOR
Drg Title : 2025-09-18_GVM_A4.ELIPTICAL AREA
Drg Date : 01-04-2026
Lower ground floor 1.0 164.25 0.15 7.00 172.46
14 COPING FINISH
14.1 COPING 1 CODE-A11-01 & 4/A11-01
Drg Title : 2025-09-18_GVM_A12-08,09-EXT ROOF ,COPING LVL DIAGRAM
Drg Date : 19-09-2025
14.2 COPING 2 CODE-A11-01 & 1/A11-01
LOWER GROUND FLOOR
(Location : ELIPTICAL )
Drg Title : 2025-09-18_GVM_A12-08,09-EXT ROOF ,COPING LVL DIAGRAM
Drg Date : 19-09-2025
Elliptical building 1.0 151.80 0.49 74.38
Drg Title : 2025-09-18_GVM_A12-08,09-EXT ROOF ,COPING LVL DIAGRAM
Drg Date : 19-09-2025
14.4 COPING 4 CODE-A11-01 & 3/A11-01
(Location : ELIPTICAL )
Drg Title : 2025-09-18_GVM_A12-08,09-EXT ROOF ,COPING LVL DIAGRAM
Drg Date : 19-09-2025
Elliptical building 2.0 121.56 0.39 94.82
Elliptical building 2.0 18.96 0.39 14.79
Elliptical building 2.0 22.74 0.39 17.74
Elliptical building 2.0 35.34 0.39 27.57
Elliptical building 4.0 1.25 0.39 1.95
Elliptical building 2.0 2.56 0.39 1.99
15.2 DOUBLE HANDLE WOODEN RAIL CODE-A12-12 & 06/A7-22
(Location : ELIPTICAL )
Drg Title : 2025-09-18_GVM_A12-12-RAILING DIAGRAM
Drg Date : 19-09-2025
Deck area 3.0 0.65 1.95
15.3 WALL MOUNTED S.S RAIL CODE-A12-12 & 01/A7-22
(Location : ELIPTICAL )
Drg Title : 2025-09-18_GVM_A12-12-RAILING DIAGRAM
Drg Date : 19-09-2025
On Mid-landing 1.0 6.25 6.25
On Mid-landing 1.0 7.46 7.46
Lower Ground Floor
(Location : ELIPTICAL )
Drg Title : 2025-09-18_GVM_A12-12-RAILING DIAGRAM
Drg Date : 19-09-2025
Mid landing-01 & 3 2.0 2.29 4.57
Mid landing-02 1.0 1.99 1.99
Floor Landing-01 (-9900 mm) 1.0 14.46 P-line 14.46
Floor Landing-02 (-8100 mm) 1.0 4.14 P-line 4.14
Mid-landing-3 (-6450 mm) 1.0 8.75 P-line 8.75
Mid-landing-4 (-4650 mm ) 1.0 8.75 P-line 8.75
(Location : ELIPTICAL )
Drg Title : 2025-09-18_GVM_A12-12-RAILING DIAGRAM
Drg Date : 19-09-2025
Floor Landing-05 (-3000mm) 1.0 10.98 P-line 10.98
Mid-landing-6 (-1350mm) 1.0 8.75 P-line 8.75
Mid-landing-7 (+450mm) 1.0 8.75 P-line 8.75
Mid-landing-8 (+2100mm) 1.0 8.75 P-line 8.75
Floor Landing-(-3000mm) 1.0 10.35 P-line 10.35
Mid-landing-6 (-1200mm) 1.0 8.75 P-line 8.75
Mid-landing-7 (+450mm) 1.0 9.35 P-line 9.35
Mid-landing-8 (+2250mm) 1.0 8.75 P-line 8.75
1st Level Plan As per A7_staricase & ramp details
(Location : Stairacse)
Drg Title : GVM_A4_DETAILED PLAN
Drg Date : 11-09-2025
Floor Landing-09 (3900mm) 1.0 10.98 P-line 10.98
Mid-landing-10 (+5550mm) 1.0 8.75 P-line 8.75
Mid-landing-11 (+7350mm) 1.0 8.75 P-line 8.75
Mid-landing-12 (+9000mm) 1.0 8.75 P-line 8.75
Floor Landing-(+3900mm) 1.0 10.26 P-line 10.26
Mid-landing-10 (+5700mm) 1.0 8.75 P-line 8.75
Mid-landing-11 (+7350mm) 1.0 8.75 P-line 8.75
Mid-landing-12 (+9150mm) 1.0 8.75 P-line 8.75
2nd Level Plan As per A7_staricase & ramp details
(Location : Stairacse)
Drg Title : GVM_A4_DETAILED PLAN
Drg Date : 11-09-2025
Floor Landing-013 (10800mm) 1.0 10.98 P-line 10.98
Mid-landing-14 (+12450mm) 1.0 8.75 P-line 8.75
Mid-landing-15 (+14250mm) 1.0 8.75 P-line 8.75
Floor Landing-(+10800mm) 1.0 13.95 P-line 13.95
Mid-landing-14 (+12450mm) 1.0 9.34 P-line 9.34
Mid-landing-15 (+14250mm) 1.0 8.75 P-line 8.75
3rd Level Plan As per A7_staricase & ramp details
(Location : Stairacse)
Drg Title : GVM_A4_DETAILED PLAN
Drg Date : 11-09-2025
Floor Landing-016 (15900mm) 1.0 10.98 P-line 10.98
Mid-landing-17 (+17550mm) 1.0 8.75 P-line 8.75
Mid-landing-18 (+19350mm) 1.0 8.75 P-line 8.75
Floor Landing-(+15900mm) 1.0 9.75 P-line 9.75
Mid-landing-17 (+17550mm) 1.0 10.84 P-line 10.84
Mid-landing-18 (+19350mm) 1.0 8.75 P-line 8.75
Floor Landing-(+20400mm) 1.0 18.88 P-line 18.88
15.4 WALL MOUNTED WOODEN RAIL CODE-A12-12 & 02/A7-22
(Location : ELIPTICAL )
Drg Title : 2025-09-18_GVM_A12-12-RAILING DIAGRAM
Drg Date : 19-09-2025
Fire exit 1.0 4.52 4.52
(Location : ELIPTICAL )
Drg Title : 2025-09-18_GVM_A12-12-RAILING DIAGRAM
Drg Date : 19-09-2025
exit ramp 2.0 26.61 53.21
Mid-landing 1.0 1.52 1.52
(Location : ELIPTICAL )
Drg Title : 2025-09-18_GVM_A12-12-RAILING DIAGRAM
Drg Date : 19-09-2025
15.5 GLASS WITH WOODEN RAIL CODE-A12-12 & 09/A7-22
(Location : ELIPTICAL )
Drg Title : 2025-09-18_GVM_A12-12-RAILING DIAGRAM
Drg Date : 19-09-2025
Railing 2.0 9.99 19.99
Railing 1.0 6.45 6.45
Railing 1.0 1.20 1.20
(Location : ELIPTICAL )
Drg Title : 2025-09-18_GVM_A12-12-RAILING DIAGRAM
Drg Date : 19-09-2025
Railing 1.0 5.43 5.43
Railing 1.0 6.45 6.45
Railing 1.0 3.40 3.40
(Location : ELIPTICAL )
Drg Title : 2025-09-18_GVM_A12-12-RAILING DIAGRAM
Drg Date : 19-09-2025
Railing 1.0 7.50 7.50
Railing 1.0 7.43 7.43
15.7 G.I RAILING CODE-A12-12 & 07/A7-22
(Location : ELIPTICAL )
Drg Title : 2025-09-18_GVM_A12-12-RAILING DIAGRAM
Drg Date : 19-09-2025
(Location : ELIPTICAL )
Drg Title : 2025-09-18_GVM_A12-12-RAILING DIAGRAM
Drg Date : 19-09-2025
Service Passage 1.0 6.00 6.00
(Location : ELIPTICAL )
Drg Title : 2025-09-18_GVM_A12-12-RAILING DIAGRAM
Drg Date : 19-09-2025
Service Passage 1.0 8.24 8.24
(Location : ELIPTICAL )
Drg Title : 2025-09-18_GVM_A12-12-RAILING DIAGRAM
Drg Date : 19-09-2025
Service Passage 1.0 6.69 6.69
(Location : ELIPTICAL )
Drg Title : 2025-09-18_GVM_A12-12-RAILING DIAGRAM
Drg Date : 19-09-2025
Service Passage 1.0 6.69 6.69
15.8 WOODEN RAIL CODE-A12-12 & 10/A7-22
(Location : ELIPTICAL )
Drg Title : 2025-09-18_GVM_A12-12-RAILING DIAGRAM
Drg Date : 19-09-2025
2nd floor to 1st floor 1.0 205.62 205.62
(Location : ELIPTICAL )
Drg Title : 2025-09-18_GVM_A12-12-RAILING DIAGRAM
Drg Date : 19-09-2025
3rd floor to 2nd floor 1.0 205.62 205.62
15.9 GLASS WITH SS CAP CODE-A12-12 & 08/A7-22
(Location : ELIPTICAL )
Drg Title : 2025-09-18_GVM_A12-12-RAILING DIAGRAM
Drg Date : 19-09-2025
Glass with saftey rail 1.0 35.66 35.66
15.11 GLASS WITH SS CAPING CODE-A12-12 & 12/A7-22
(Location : ELIPTICAL )
Drg Title : 2025-09-18_GVM_A12-12-RAILING DIAGRAM
Drg Date : 19-09-2025
Serive ramp 1.0 38.56 38.56
15.12 GLASS WITH WOODEN RAIL CODE-A12-12 & 13/A7-22
(Location : ELIPTICAL )
Drg Title : 2025-09-18_GVM_A12-12-RAILING DIAGRAM
Drg Date : 19-09-2025
Serive ramp 1.0 26.87 26.87
14 PRECAST PANELS
avg top and bottom length
LOWER GROUND FLOOR
Drg Title : 2025-09-18_GVM_A4.ELIPTICAL AREA
Drg Date : 01-04-2026
Lower ground floor 1.0 160.46 0.15 7.01 168.67
Ded of Fresh air passage opn -1.0 2.75 0.15 2.49 -1.03
Ded of entrance lobby -1.0 5.10 0.15 2.95 -2.26
Ded of door from north block (D-J-L-02) -1.0 1.50 0.15 2.40 -0.54
Ded of Fresh air passage opn -1.0 2.75 0.15 6.90 -2.85
Ded of door from north block (D-J-G-01) -1.0 1.50 0.15 2.40 -0.54 3rd 133.899
Ded of Fresh air passage opn -1.0 2.75 0.15 6.90 -2.85
Ded of exit bridge -1.0 2.83 0.15 4.24 -1.80
Terrace floor 4.0 11.10 0.15 2.57 17.09
@ LOUVER BACKING WITH 19MM PLY + 12MM THK TEAK WOOD PANEL
(Location : ELIPTICAL )
Drg Title : 2025-09-18_GVM_A12-12-RAILING DIAGRAM
Drg Date : 19-09-2025
@ TEAK WOOD LOUVERS
(Location : ELIPTICAL )
Drg Title : 2025-09-18_GVM_A12-12-RAILING DIAGRAM
Drg Date : 19-09-2025
Serive ramp 20.0 12.70 254.00
SuPr ENGINEERING CONSULTANTS 307, SIDDHARTH UPSCALE, VASNA ROAD VADODARA-390007 TEL- 0265-3149701 SUMMARY
VADODARA PROJECT : GUJARAT VANDANA MUSEUM, GUJARAT
DATE : 05-09-25 ARCHITECT : OPOLIS
PREPARED BY : MANDIPSINH CLIENT : DIRECTORATE OF ARCHEOLOGY AND MUSEUMS, G.O.G
SR. NO. PARTICULAR UNIT QTY. NO. OF FLOORS TOTAL QTY. QTY. WITH CONTIGENCY
R0 DWGS-RECD-07.07.25
2 MASONRY WORK (AAC WALL)
2.4 200MM THICK AAC BLOCK MASONRY CODE-A13-01 & 1/A13-08
Ground Floor Sqm 387.09 1.00 387.09
Total Sqm 387.09 407.00
2.6 300MM THICK AAC BLOCK MASONRY CODE-A13-01 & 1/A13-08
Ground Floor Cum 17.27 1.00 17.27
Total Cum 17.27 19.00
4.1 150 MM THICK AAC BLOCK MASONRY CODE-01A13-08
Ground Floor Sqm 9.35 1.00 9.35
Total Sqm 9.35 10.00
3 INTERNAL PLATSER WORK
Ground Floor Sqm 380.36 1.00 380.36
Total Sqm 380.36 400.00
4 INTERNAL PUTTY WORK
Ground Floor Sqm 12.16 1.00 12.16
Total Sqm 12.16 13.00
Ground Floor Sqm 164.35 1.00 164.35
Total Sqm 164.35 173.00
Ground Floor Sqm 65.85 1.00 65.85
Total Sqm 65.85 70.00
CEILING PLASTER
Ground Floor Sqm 172.84 1.00 172.84
Total Sqm 172.84 182.00
EXTERNAL PLASTER
Ground Floor Sqm 832.23 1.00 832.23
Total Sqm 832.23 874.00
13 WATERPROOFING WORK
13.1 LOCATION : TOILET
Ground Floor Sqm 97.26 1.00 97.26
Total Sqm 97.26 107.00
13.4 LOCATION : TERRACE
Ground Floor Sqm 172.84 1.00 172.84
Total Sqm 172.84 191.00
Ground Floor Cum 11.65 1.00 11.65
Total Cum 11.65 13.00
5 FLOORING WORK
5.1 MANDANA-1 (25MM THICK GRANITE) FLOORING CODE-A12-04 & 1/A14-01
Basement Floor Sqm 0.00 1.00 0.00
Lower Ground Floor Sqm 0.00 1.00 0.00
Mezzanine Floor Sqm 0.00 1.00 0.00
Ground Floor Sqm 0.00 1.00 0.00
First Floor Sqm 0.00 1.00 0.00
Second Floor Sqm 0.00 1.00 0.00
Third Floor Sqm 0.00 1.00 0.00
Fourth Floor Sqm 0.00 1.00 0.00
Total Sqm 0.00 0.00
5.2 T.W WOOD PLANKS 25MM (SOLID WOOD FLOOR) CODE-A12-04 & 5/A14-01
Basement Floor Sqm 0.00 1.00 0.00
Lower Ground Floor Sqm 0.00 1.00 0.00
Mezzanine Floor Sqm 0.00 1.00 0.00
Ground Floor Sqm 0.00 1.00 0.00
First Floor Sqm 0.00 1.00 0.00
Second Floor Sqm 0.00 1.00 0.00
Third Floor Sqm 0.00 1.00 0.00
Fourth Floor Sqm 0.00 1.00 0.00
Total Sqm 0.00 0.00
5.3 VDF CONCERETE FLOORING CODE-A12-04 & 2/A14-02
Basement Floor Sqm 0.00 1.00 0.00
Lower Ground Floor Sqm 0.00 1.00 0.00
Mezzanine Floor Sqm 0.00 1.00 0.00
Ground Floor Sqm 0.00 1.00 0.00
First Floor Sqm 0.00 1.00 0.00
Second Floor Sqm 0.00 1.00 0.00
Third Floor Sqm 0.00 1.00 0.00
Fourth Floor Sqm 0.00 1.00 0.00
Total Sqm 0.00 0.00
5.4 25MM THICK SANDSTONE CODE-A12-04 & 1/A14-01
Basement Floor Sqm 0.00 1.00 0.00
Lower Ground Floor Sqm 0.00 1.00 0.00
Mezzanine Floor Sqm 0.00 1.00 0.00
Ground Floor Sqm 0.00 1.00 0.00
First Floor Sqm 0.00 1.00 0.00
Second Floor Sqm 0.00 1.00 0.00
Third Floor Sqm 0.00 1.00 0.00
Fourth Floor Sqm 0.00 1.00 0.00
Total Sqm 0.00 0.00
5.5 25MM THICK STEEL GREY GRANITE FLOORING CODE-A12-04 & 1/A14-01
Ground Floor Sqm 32.23 1.00 32.23
Total Sqm 32.23 34.00
5.6 WOODEN DECK CODE-A12-04 & 12/A14-01
Basement Floor Sqm 0.00 1.00 0.00
Lower Ground Floor Sqm 0.00 1.00 0.00
Mezzanine Floor Sqm 0.00 1.00 0.00
Ground Floor Sqm 0.00 1.00 0.00
First Floor Sqm 0.00 1.00 0.00
Second Floor Sqm 0.00 1.00 0.00
Third Floor Sqm 0.00 1.00 0.00
Fourth Floor Sqm 0.00 1.00 0.00
Total Sqm 0.00 0.00
5.7 MANDANA-2 (25MM THICK GRANITE) FLOORING CODE-A12-04 & 1/A14-01
Basement Floor Sqm 0.00 1.00 0.00
Lower Ground Floor Sqm 0.00 1.00 0.00
Mezzanine Floor Sqm 0.00 1.00 0.00
Ground Floor Sqm 0.00 1.00 0.00
First Floor Sqm 0.00 1.00 0.00
Second Floor Sqm 0.00 1.00 0.00
Third Floor Sqm 0.00 1.00 0.00
Fourth Floor Sqm 0.00 1.00 0.00
Total Sqm 0.00 0.00
5.8 RUBBER TILE FLOORING CODE-A12-04 & 3/A14-01
Basement Floor Sqm 0.00 1.00 0.00
Lower Ground Floor Sqm 0.00 1.00 0.00
Mezzanine Floor Sqm 0.00 1.00 0.00
Ground Floor Sqm 0.00 1.00 0.00
First Floor Sqm 0.00 1.00 0.00
Second Floor Sqm 0.00 1.00 0.00
Third Floor Sqm 0.00 1.00 0.00
Fourth Floor Sqm 0.00 1.00 0.00
Total Sqm 0.00 0.00
6 WALL FINISH WORK
6.1 SANDSTONE CLADDING DRG CODE- A12-05 REF : 6/A14-02
Basement Floor Sqm 0.00 1.00 0.00
Lower Ground Floor Sqm 0.00 1.00 0.00
Mezzanine Floor Sqm 0.00 1.00 0.00
Ground Floor Sqm 0.00 1.00 0.00
First Floor Sqm 0.00 1.00 0.00
Second Floor Sqm 0.00 1.00 0.00
Third Floor Sqm 0.00 1.00 0.00
Fourth Floor Sqm 0.00 1.00 0.00
Total Sqm 0.00 0.00
6.2 FIRE RATED GYPSUM BOARD + PAINT DRG CODE- A12-05 REF : 17/A14-02
Basement Floor Sqm 0.00 1.00 0.00
Lower Ground Floor Sqm 0.00 1.00 0.00
Mezzanine Floor Sqm 0.00 1.00 0.00
Ground Floor Sqm 0.00 1.00 0.00
First Floor Sqm 0.00 1.00 0.00
Second Floor Sqm 0.00 1.00 0.00
Third Floor Sqm 0.00 1.00 0.00
Fourth Floor Sqm 0.00 1.00 0.00
Total Sqm 0.00 0.00
6.3 WOODEN PANELING DRG CODE- A12-05 REF : 7/A14-02
Basement Floor Sqm 0.00 1.00 0.00
Lower Ground Floor Sqm 0.00 1.00 0.00
Mezzanine Floor Sqm 0.00 1.00 0.00
Ground Floor Sqm 0.00 1.00 0.00
First Floor Sqm 0.00 1.00 0.00
Second Floor Sqm 0.00 1.00 0.00
Third Floor Sqm 0.00 1.00 0.00
Fourth Floor Sqm 0.00 1.00 0.00
Total Sqm 0.00 0.00
6.4 MANDANA STONE-3 CLADDING DRG CODE- A12-05 REF : 6/A14-02
Ground Floor Sqm 56.31 1.00 56.31
Total Sqm 56.31 60.00
6.5 GRANITE CLADDING DRG CODE- A12-05 REF : 6/A14-02
Basement Floor Sqm 0.00 1.00 0.00
Lower Ground Floor Sqm 0.00 1.00 0.00
Mezzanine Floor Sqm 0.00 1.00 0.00
Ground Floor Sqm 0.00 1.00 0.00
First Floor Sqm 0.00 1.00 0.00
Second Floor Sqm 0.00 1.00 0.00
Third Floor Sqm 0.00 1.00 0.00
Fourth Floor Sqm 0.00 1.00 0.00
Total Sqm 0.00 0.00
6.6 S.S CLADDING DRG CODE- A12-05 REF : 13/A14-02
Basement Floor Sqm 0.00 1.00 0.00
Lower Ground Floor Sqm 0.00 1.00 0.00
Mezzanine Floor Sqm 0.00 1.00 0.00
Ground Floor Sqm 0.00 1.00 0.00
First Floor Sqm 0.00 1.00 0.00
Second Floor Sqm 0.00 1.00 0.00
Third Floor Sqm 0.00 1.00 0.00
Fourth Floor Sqm 0.00 1.00 0.00
Total Sqm 0.00 0.00
6.7 VITRIFIED TILES CLADDING DRG CODE- A12-05 REF : 8/A14-02
Ground Floor Sqm 126.36 1.00 126.36
Total Sqm 126.36 133.00
6.8 MIRROR POLISHED GRANITE CLADDING DRG CODE- A12-05 REF : 6/A14-02
Basement Floor Sqm 0.00 1.00 0.00
Lower Ground Floor Sqm 0.00 1.00 0.00
Mezzanine Floor Sqm 0.00 1.00 0.00
Ground Floor Sqm 0.00 1.00 0.00
First Floor Sqm 0.00 1.00 0.00
Second Floor Sqm 0.00 1.00 0.00
Third Floor Sqm 0.00 1.00 0.00
Fourth Floor Sqm 0.00 1.00 0.00
Total Sqm 0.00 0.00
6.9 VENEER CLADDING DRG CODE- A12-05 REF : 16/A14-02
Basement Floor Sqm 0.00 1.00 0.00
Lower Ground Floor Sqm 0.00 1.00 0.00
Mezzanine Floor Sqm 0.00 1.00 0.00
Ground Floor Sqm 0.00 1.00 0.00
First Floor Sqm 0.00 1.00 0.00
Second Floor Sqm 0.00 1.00 0.00
Third Floor Sqm 0.00 1.00 0.00
Fourth Floor Sqm 0.00 1.00 0.00
Total Sqm 0.00 0.00
8 FALSE CEILING WORK
8.1 PUNCHED GYPSUM + ACOUSTIC CODE-A12-07 & 3/A14-04
Basement Floor Sqm 0.00 1.00 0.00
Lower Ground Floor Sqm 0.00 1.00 0.00
Mezzanine Floor Sqm 0.00 1.00 0.00
Ground Floor Sqm 0.00 1.00 0.00
First Floor Sqm 0.00 1.00 0.00
Second Floor Sqm 0.00 1.00 0.00
Third Floor Sqm 0.00 1.00 0.00
Fourth Floor Sqm 0.00 1.00 0.00
Total Sqm 0.00 0.00
8.2 ALUMINUM PANELS CODE-A12-07 & 4/A14-04
Ground Floor Sqm 390.74 1.00 390.74
Total Sqm 390.74 411.00
Ground Floor Sqm 18.59 1.00 18.59
Total Sqm 18.59 20.00
8.3 GYPSUM + ACOUSTIC LINING CODE-A12-07 & 1/A14-04
Basement Floor Sqm 0.00 1.00 0.00
Lower Ground Floor Sqm 0.00 1.00 0.00
Mezzanine Floor Sqm 0.00 1.00 0.00
Ground Floor Sqm 0.00 1.00 0.00
First Floor Sqm 0.00 1.00 0.00
Second Floor Sqm 0.00 1.00 0.00
Third Floor Sqm 0.00 1.00 0.00
Fourth Floor Sqm 0.00 1.00 0.00
Total Sqm 0.00 0.00
8.4 (AUDI) GYPSUM + ACOUSTIC CODE-A12-07 & 2A/A14-04
Basement Floor Sqm 0.00 1.00 0.00
Lower Ground Floor Sqm 0.00 1.00 0.00
Mezzanine Floor Sqm 0.00 1.00 0.00
Ground Floor Sqm 0.00 1.00 0.00
First Floor Sqm 0.00 1.00 0.00
Second Floor Sqm 0.00 1.00 0.00
Third Floor Sqm 0.00 1.00 0.00
Fourth Floor Sqm 0.00 1.00 0.00
Total Sqm 0.00 0.00
8.5 WOODEN CEILING CODE-A12-07 & 9/A14-04
Basement Floor Sqm 0.00 1.00 0.00
Lower Ground Floor Sqm 0.00 1.00 0.00
Mezzanine Floor Sqm 0.00 1.00 0.00
Ground Floor Sqm 0.00 1.00 0.00
First Floor Sqm 0.00 1.00 0.00
Second Floor Sqm 0.00 1.00 0.00
Third Floor Sqm 0.00 1.00 0.00
Fourth Floor Sqm 0.00 1.00 0.00
Total Sqm 0.00 0.00
8.6 WOODEN SLATS CODE-A12-07 & 10/A14-04
Basement Floor Sqm 0.00 1.00 0.00
Lower Ground Floor Sqm 0.00 1.00 0.00
Mezzanine Floor Sqm 0.00 1.00 0.00
Ground Floor Sqm 0.00 1.00 0.00
First Floor Sqm 0.00 1.00 0.00
Second Floor Sqm 0.00 1.00 0.00
Third Floor Sqm 0.00 1.00 0.00
Fourth Floor Sqm 0.00 1.00 0.00
Total Sqm 0.00 0.00
8.7 FRP CANOPY CODE-A12-07 & 7/A14-04
Basement Floor Sqm 0.00 1.00 0.00
Lower Ground Floor Sqm 0.00 1.00 0.00
Mezzanine Floor Sqm 0.00 1.00 0.00
Ground Floor Sqm 0.00 1.00 0.00
First Floor Sqm 0.00 1.00 0.00
Second Floor Sqm 0.00 1.00 0.00
Third Floor Sqm 0.00 1.00 0.00
Fourth Floor Sqm 0.00 1.00 0.00
Total Sqm 0.00 0.00
8.8 ALUMINIUM GRILL CODE-A12-07 & 22/A14-04
Basement Floor Sqm 0.00 1.00 0.00
Lower Ground Floor Sqm 0.00 1.00 0.00
Mezzanine Floor Sqm 0.00 1.00 0.00
Ground Floor Sqm 0.00 1.00 0.00
First Floor Sqm 0.00 1.00 0.00
Second Floor Sqm 0.00 1.00 0.00
Third Floor Sqm 0.00 1.00 0.00
Fourth Floor Sqm 0.00 1.00 0.00
Total Sqm 0.00 0.00
5.9 25MM THICK KOTA STONE FLOORING CODE-A12-04 & 4/A14-01
Ground Floor Sqm 97.82 1.00 97.82
Total Sqm 97.82 103.00
5.10 SEALED CONCRETE FLOORING CODE-A12-04 & 13A/A14-01
Basement Floor Sqm 0.00 1.00 0.00
Lower Ground Floor Sqm 0.00 1.00 0.00
Mezzanine Floor Sqm 0.00 1.00 0.00
Ground Floor Sqm 0.00 1.00 0.00
First Floor Sqm 0.00 1.00 0.00
Second Floor Sqm 0.00 1.00 0.00
Third Floor Sqm 0.00 1.00 0.00
Fourth Floor Sqm 0.00 1.00 0.00
Total Sqm 0.00 0.00
5.11 WALK OF MAT CODE-A12-04 & 8/A14-01
Basement Floor Sqm 0.00 1.00 0.00
Lower Ground Floor Sqm 0.00 1.00 0.00
Mezzanine Floor Sqm 0.00 1.00 0.00
Ground Floor Sqm 0.00 1.00 0.00
First Floor Sqm 0.00 1.00 0.00
Second Floor Sqm 0.00 1.00 0.00
Third Floor Sqm 0.00 1.00 0.00
Fourth Floor Sqm 0.00 1.00 0.00
Total Sqm 0.00 0.00
5.12 GRATING CODE-A12-04 & 6/A14-01
Basement Floor Sqm 0.00 1.00 0.00
Lower Ground Floor Sqm 0.00 1.00 0.00
Mezzanine Floor Sqm 0.00 1.00 0.00
Ground Floor Sqm 0.00 1.00 0.00
First Floor Sqm 0.00 1.00 0.00
Second Floor Sqm 0.00 1.00 0.00
Third Floor Sqm 0.00 1.00 0.00
Fourth Floor Sqm 0.00 1.00 0.00
Total Sqm 0.00 0.00
5.13 8MM THICK WHITE GLAZED TILES CODE-A12-04 & 11/A14-01
Basement Floor Sqm 0.00 1.00 0.00
Lower Ground Floor Sqm 0.00 1.00 0.00
Mezzanine Floor Sqm 0.00 1.00 0.00
Ground Floor Sqm 0.00 1.00 0.00
First Floor Sqm 0.00 1.00 0.00
Second Floor Sqm 0.00 1.00 0.00
Third Floor Sqm 0.00 1.00 0.00
Fourth Floor Sqm 0.00 1.00 0.00
Total Sqm 0.00 0.00
5.14 10 MM THICK VITRIFIED TILES FLOORING CODE-A12-04 & 7/A14-01
Ground Floor Sqm 32.23 1.00 32.23
Total Sqm 32.23 34.00
5.15 RAISED ANTI-STATIC FLOORING CODE-A12-04 & 9/A14-01
Basement Floor Sqm 0.00 1.00 0.00
Lower Ground Floor Sqm 0.00 1.00 0.00
Mezzanine Floor Sqm 0.00 1.00 0.00
Ground Floor Sqm 0.00 1.00 0.00
First Floor Sqm 0.00 1.00 0.00
Second Floor Sqm 0.00 1.00 0.00
Third Floor Sqm 0.00 1.00 0.00
Fourth Floor Sqm 0.00 1.00 0.00
Total Sqm 0.00 0.00
5.16 NYLON MATT FLOORING CODE-A12-04 & 10/A14-01
Basement Floor Sqm 0.00 1.00 0.00
Lower Ground Floor Sqm 0.00 1.00 0.00
Mezzanine Floor Sqm 0.00 1.00 0.00
Ground Floor Sqm 0.00 1.00 0.00
First Floor Sqm 0.00 1.00 0.00
Second Floor Sqm 0.00 1.00 0.00
Third Floor Sqm 0.00 1.00 0.00
Fourth Floor Sqm 0.00 1.00 0.00
Total Sqm 0.00 0.00
5.18 25 MM THICK GRAY GRANITE FLOORING CODE-A12-04 & 1/A14-01
Basement Floor Sqm 0.00 1.00 0.00
Lower Ground Floor Sqm 0.00 1.00 0.00
Mezzanine Floor Sqm 0.00 1.00 0.00
Ground Floor Sqm 0.00 1.00 0.00
First Floor Sqm 0.00 1.00 0.00
Second Floor Sqm 0.00 1.00 0.00
Third Floor Sqm 0.00 1.00 0.00
Fourth Floor Sqm 0.00 1.00 0.00
Total Sqm 0.00 0.00
5.20 25MM THICK KOTA STONE FLOORING CODE-A12-04 & 4/A14-01 (LOCATION : Staircase)
Basement Floor Sqm 0.00 1.00 0.00
Lower Ground Floor Sqm 0.00 1.00 0.00
Mezzanine Floor Sqm 0.00 1.00 0.00
Ground Floor Sqm 0.00 1.00 0.00
First Floor Sqm 0.00 1.00 0.00
Second Floor Sqm 0.00 1.00 0.00
Third Floor Sqm 0.00 1.00 0.00
Fourth Floor Sqm 0.00 1.00 0.00
Total Sqm 0.00 0.00
5.20 MANDANA-1 (25MM THICK GRANITE) STAIRCASE FLOORING CODE-A12-04 & 1/A14-01
Basement Floor Sqm 0.00 1.00 0.00
Lower Ground Floor Sqm 0.00 1.00 0.00
Mezzanine Floor Sqm 0.00 1.00 0.00
Ground Floor Sqm 0.00 1.00 0.00
First Floor Sqm 0.00 1.00 0.00
Second Floor Sqm 0.00 1.00 0.00
Third Floor Sqm 0.00 1.00 0.00
Fourth Floor Sqm 0.00 1.00 0.00
Total Sqm 0.00 0.00
5.21 25MM THICK KOTA STONE-TREADS CODE-A12-04 & 4/A14-01 (LOCATION : Staircase)
Basement Floor Rmt 0.00 1.00 0.00
Lower Ground Floor Rmt 0.00 1.00 0.00
Mezzanine Floor Rmt 0.00 1.00 0.00
Ground Floor Rmt 0.00 1.00 0.00
First Floor Rmt 0.00 1.00 0.00
Second Floor Rmt 0.00 1.00 0.00
Third Floor Rmt 0.00 1.00 0.00
Fourth Floor Rmt 0.00 1.00 0.00
Total Rmt 0.00 0.00
Total Sqm 0.30 0.00 0.00
5.22 MANDANA-1 (25MM THICK GRANITE) TREADS CODE-A12-04 & 1/A14-01
Basement Floor Rmt 0.00 1.00 0.00
Lower Ground Floor Rmt 0.00 1.00 0.00
Mezzanine Floor Rmt 0.00 1.00 0.00
Ground Floor Rmt 0.00 1.00 0.00
First Floor Rmt 0.00 1.00 0.00
Second Floor Rmt 0.00 1.00 0.00
Third Floor Rmt 0.00 1.00 0.00
Fourth Floor Rmt 0.00 1.00 0.00
Total Rmt 0.00 0.00
Total Sqm 0.30 0.00 0.00
5.23 25MM THICK KOTA STONE-RISERS CODE-A12-04 & 4/A14-01 (LOCATION : Staircase)
Basement Floor Rmt 0.00 1.00 0.00
Lower Ground Floor Rmt 0.00 1.00 0.00
Mezzanine Floor Rmt 0.00 1.00 0.00
Ground Floor Rmt 0.00 1.00 0.00
First Floor Rmt 0.00 1.00 0.00
Second Floor Rmt 0.00 1.00 0.00
Third Floor Rmt 0.00 1.00 0.00
Fourth Floor Rmt 0.00 1.00 0.00
Total Rmt 0.00 0.00
Total Sqm 0.15 0.00 0.00
5.24 MANDANA-1 (25MM THICK GRANITE) RISERS CODE-A12-04 & 1/A14-01
Basement Floor Rmt 0.00 1.00 0.00
Lower Ground Floor Rmt 0.00 1.00 0.00
Mezzanine Floor Rmt 0.00 1.00 0.00
Ground Floor Rmt 0.00 1.00 0.00
First Floor Rmt 0.00 1.00 0.00
Second Floor Rmt 0.00 1.00 0.00
Third Floor Rmt 0.00 1.00 0.00
Fourth Floor Rmt 0.00 1.00 0.00
Total Rmt 0.00 0.00
Total Sqm 0.15 0.00 0.00
5.23 25MM THICK KOTA STONE-SKIRTING CODE-A12-04 & 4/A14-01 (LOCATION : Staircase)
Basement Floor Rmt 0.00 1.00 0.00
Lower Ground Floor Rmt 0.00 1.00 0.00
Mezzanine Floor Rmt 0.00 1.00 0.00
Ground Floor Rmt 0.00 1.00 0.00
First Floor Rmt 0.00 1.00 0.00
Second Floor Rmt 0.00 1.00 0.00
Third Floor Rmt 0.00 1.00 0.00
Fourth Floor Rmt 0.00 1.00 0.00
Total Rmt 0.00 0.00
Total Sqm 0.10 0.00 0.00
5.24 25MM THICK KOTA STONE-INCLINED SKIRTING CODE-A12-04 & 4/A14-01 (LOCATION : Staircase)
Basement Floor Rmt 0.00 1.00 0.00
Lower Ground Floor Rmt 0.00 1.00 0.00
Mezzanine Floor Rmt 0.00 1.00 0.00
Ground Floor Rmt 0.00 1.00 0.00
First Floor Rmt 0.00 1.00 0.00
Second Floor Rmt 0.00 1.00 0.00
Third Floor Rmt 0.00 1.00 0.00
Fourth Floor Rmt 0.00 1.00 0.00
Total Rmt 0.00 0.00
Total Sqm 0.10 0.00 0.00
5.23 MANDANA-1 (25MM THICK GRANITE) STAIRCASE SKIRTING CODE-A12-04 & 1/A14-01
Basement Floor Rmt 0.00 1.00 0.00
Lower Ground Floor Rmt 0.00 1.00 0.00
Mezzanine Floor Rmt 0.00 1.00 0.00
Ground Floor Rmt 0.00 1.00 0.00
First Floor Rmt 0.00 1.00 0.00
Second Floor Rmt 0.00 1.00 0.00
Third Floor Rmt 0.00 1.00 0.00
Fourth Floor Rmt 0.00 1.00 0.00
Total Rmt 0.00 0.00
Total Sqm 0.10 0.00 0.00
5.24 MANDANA-1 (25MM THICK GRANITE) STAIRCASE INCLINED SKIRTING CODE-A12-04 & 1/A14-01
Basement Floor Rmt 0.00 1.00 0.00
Lower Ground Floor Rmt 0.00 1.00 0.00
Mezzanine Floor Rmt 0.00 1.00 0.00
Ground Floor Rmt 0.00 1.00 0.00
First Floor Rmt 0.00 1.00 0.00
Second Floor Rmt 0.00 1.00 0.00
Third Floor Rmt 0.00 1.00 0.00
Fourth Floor Rmt 0.00 1.00 0.00
Total Rmt 0.00 0.00
Total Sqm 0.10 0.00 0.00
6.10 VITRIFIED TILES-2 CLADDING DRG CODE- A12-05 REF : 8/A14-02
Ground Floor Sqm 27.91 1.00 27.91
Total Sqm 27.91 30.00
6.11 GYPSUM PLASTER + PAINT DRG CODE- A12-05 REF : 10/A14-02
Ground Floor Sqm 307.66 1.00 307.66
Total Sqm 307.66 324.00
6.12 GYPSUM PARTITION WALL SYSTEM DRG CODE- A12-05 REF : 9/A14-02
Basement Floor Sqm 0.00 1.00 0.00
Lower Ground Floor Sqm 0.00 1.00 0.00
Mezzanine Floor Sqm 0.00 1.00 0.00
Ground Floor Sqm 0.00 1.00 0.00
First Floor Sqm 0.00 1.00 0.00
Second Floor Sqm 0.00 1.00 0.00
Third Floor Sqm 0.00 1.00 0.00
Fourth Floor Sqm 0.00 1.00 0.00
Total Sqm 0.00 0.00
6.13 SOUND ATTENAUTION DRG CODE- A12-05 REF : 11/A14-02
Basement Floor Sqm 0.00 1.00 0.00
Lower Ground Floor Sqm 0.00 1.00 0.00
Mezzanine Floor Sqm 0.00 1.00 0.00
Ground Floor Sqm 0.00 1.00 0.00
First Floor Sqm 0.00 1.00 0.00
Second Floor Sqm 0.00 1.00 0.00
Third Floor Sqm 0.00 1.00 0.00
Fourth Floor Sqm 0.00 1.00 0.00
Total Sqm 0.00 0.00
6.14 WHITE GLAZED VITRIFIED TILES CLADDING DRG CODE- A12-05 REF : 8/A14-02
Basement Floor Sqm 0.00 1.00 0.00
Lower Ground Floor Sqm 0.00 1.00 0.00
Mezzanine Floor Sqm 0.00 1.00 0.00
Ground Floor Sqm 0.00 1.00 0.00
First Floor Sqm 0.00 1.00 0.00
Second Floor Sqm 0.00 1.00 0.00
Third Floor Sqm 0.00 1.00 0.00
Fourth Floor Sqm 0.00 1.00 0.00
Total Sqm 0.00 0.00
6.15 PLASTER + PAINT DRG CODE- A12-05 REF : 14/A14-02
Basement Floor Sqm 0.00 1.00 0.00
Lower Ground Floor Sqm 0.00 1.00 0.00
Mezzanine Floor Sqm 0.00 1.00 0.00
Ground Floor Sqm 0.00 1.00 0.00
First Floor Sqm 0.00 1.00 0.00
Second Floor Sqm 0.00 1.00 0.00
Third Floor Sqm 0.00 1.00 0.00
Fourth Floor Sqm 0.00 1.00 0.00
Total Sqm 0.00 0.00
6.16 PLASTER FINISH DRG CODE- A12-05 REF : 15/A14-02
Ground Floor Sqm 50.46 1.00 50.46
Total Sqm 50.46 53.00
6.17 ALUMINIUM CLADDING DRG CODE- A12-05 REF : 12/A14-02
Basement Floor Sqm 0.00 1.00 0.00
Lower Ground Floor Sqm 0.00 1.00 0.00
Mezzanine Floor Sqm 0.00 1.00 0.00
Ground Floor Sqm 0.00 1.00 0.00
First Floor Sqm 0.00 1.00 0.00
Second Floor Sqm 0.00 1.00 0.00
Third Floor Sqm 0.00 1.00 0.00
Fourth Floor Sqm 0.00 1.00 0.00
Total Sqm 0.00 0.00
7 SKIRTING WORK
7.1 WOODEN SKIRTING CODE-A12-06 & 3/A14-03
Basement Floor Rmt 0.00 1.00 0.00
Lower Ground Floor Rmt 0.00 1.00 0.00
Mezzanine Floor Rmt 0.00 1.00 0.00
Ground Floor Rmt 0.00 1.00 0.00
First Floor Rmt 0.00 1.00 0.00
Second Floor Rmt 0.00 1.00 0.00
Third Floor Rmt 0.00 1.00 0.00
Fourth Floor Rmt 0.00 1.00 0.00
Total Rmt 0.00 0.00
7.2 KOTA STONE SKIRTING (LOADING BAY) CODE-A12-06 & 2/A14-03
Basement Floor Sqm 0.00 1.00 0.00
Lower Ground Floor Sqm 0.00 1.00 0.00
Mezzanine Floor Sqm 0.00 1.00 0.00
Ground Floor Sqm 0.00 1.00 0.00
First Floor Sqm 0.00 1.00 0.00
Second Floor Sqm 0.00 1.00 0.00
Third Floor Sqm 0.00 1.00 0.00
Fourth Floor Sqm 0.00 1.00 0.00
Total Sqm 0.00 0.00
7.3 KOTA STONE SKIRTING CODE-A12-06 & 1/A14-03
Ground Floor rmt 90.06 1.00 90.06
Total rmt 90.06 95.00
7.4 S.S BASE (COLUMN) CODE-A12-06 & 4/A14-03
Basement Floor Sqm 0.00 1.00 0.00
Lower Ground Floor Sqm 0.00 1.00 0.00
Mezzanine Floor Sqm 0.00 1.00 0.00
Ground Floor Sqm 0.00 1.00 0.00
First Floor Sqm 0.00 1.00 0.00
Second Floor Sqm 0.00 1.00 0.00
Third Floor Sqm 0.00 1.00 0.00
Fourth Floor Sqm 0.00 1.00 0.00
Total Sqm 0.00 0.00
8 FALSE CEILING WORK
8.9 MINERAL FIBRE GRID CEILING 600X600 CODE-A12-07 & 2/A14-04
Ground Floor Sqm 32.24 1.00 32.24
Total Sqm 32.24 34.00
8.10 GYPSUM + PAINT CODE-A12-07 & 5/A14-04
Ground Floor Sqm 48.06 1.00 48.06
Total Sqm 48.06 51.00
8.11 PLASTER FINISH CODE-A12-07
Basement Floor Sqm 0.00 1.00 0.00
Lower Ground Floor Sqm 0.00 1.00 0.00
Mezzanine Floor Sqm 0.00 1.00 0.00
Ground Floor Sqm 0.00 1.00 0.00
First Floor Sqm 0.00 1.00 0.00
Second Floor Sqm 0.00 1.00 0.00
Third Floor Sqm 0.00 1.00 0.00
Fourth Floor Sqm 0.00 1.00 0.00
Total Sqm 0.00 0.00
8.12 METAL CEILING CODE-A12-07 & 11/A14-04
Basement Floor Sqm 0.00 1.00 0.00
Lower Ground Floor Sqm 0.00 1.00 0.00
Mezzanine Floor Sqm 0.00 1.00 0.00
Ground Floor Sqm 0.00 1.00 0.00
First Floor Sqm 0.00 1.00 0.00
Second Floor Sqm 0.00 1.00 0.00
Third Floor Sqm 0.00 1.00 0.00
Fourth Floor Sqm 0.00 1.00 0.00
Total Sqm 0.00 0.00
8.13 PLASTER + PAINT CODE-A12-07 & 5/A14-04
Ground Floor Sqm 39.93 1.00 39.93
Total Sqm 39.93 42.00
8.14 SOUND ATTENUATION CODE-A12-07 & 8/A14-04
Basement Floor Sqm 0.00 1.00 0.00
Lower Ground Floor Sqm 0.00 1.00 0.00
Mezzanine Floor Sqm 0.00 1.00 0.00
Ground Floor Sqm 0.00 1.00 0.00
First Floor Sqm 0.00 1.00 0.00
Second Floor Sqm 0.00 1.00 0.00
Third Floor Sqm 0.00 1.00 0.00
Fourth Floor Sqm 0.00 1.00 0.00
Total Sqm 0.00 0.00
8.15 M.R GRADE GYPSUM GRID 600X600 CODE-A12-07 & 7/A14-04
Basement Floor Sqm 1.00 0.00
Lower Ground Floor Sqm 1.00 0.00
Mezzanine Floor Sqm 1.00 0.00
Ground Floor Sqm 1.00 0.00
First Floor Sqm 1.00 0.00
Second Floor Sqm 1.00 0.00
Third Floor Sqm 1.00 0.00
Fourth Floor Sqm 1.00 0.00
Total Sqm 0.00 0.00
8.16 BARRIOL CEILING CODE-A12-07 & 20/A14-04
Basement Floor Sqm 0.00 1.00 0.00
Lower Ground Floor Sqm 0.00 1.00 0.00
Mezzanine Floor Sqm 0.00 1.00 0.00
Ground Floor Sqm 0.00 1.00 0.00
First Floor Sqm 0.00 1.00 0.00
Second Floor Sqm 0.00 1.00 0.00
Third Floor Sqm 0.00 1.00 0.00
Fourth Floor Sqm 0.00 1.00 0.00
Total Sqm 0.00 0.00
9 PARAPET FINISH
9.1 2 SIDE PLASTER CODE-A11-01 & 4/A11-01
Basement Floor Sqm 1.00 0.00
Lower Ground Floor Sqm 1.00 0.00
Mezzanine Floor Sqm 1.00 0.00
Ground Floor Sqm 1.00 0.00
First Floor Sqm 1.00 0.00
Second Floor Sqm 1.00 0.00
Third Floor Sqm 1.00 0.00
Fourth Floor Sqm 1.00 0.00
Total Sqm 0.00 0.00
9.2 1SIDE STONE CLADDING CODE-A11-01 & 1/A11-01
Ground Floor Sqm 38.99 1.00 38.99
Total Sqm 38.99 41.00
9.3 EXTENDED CLADDING CODE-A11-01 & 2/A11-01
Basement Floor Sqm 1.00 0.00
Lower Ground Floor Sqm 1.00 0.00
Mezzanine Floor Sqm 1.00 0.00
Ground Floor Sqm 1.00 0.00
First Floor Sqm 1.00 0.00
Second Floor Sqm 1.00 0.00
Third Floor Sqm 1.00 0.00
Fourth Floor Sqm 1.00 0.00
Total Sqm 0.00 0.00
9.4 2 SIDE STONE CLADDING CODE-A11-01 & 3/A11-01
Basement Floor Sqm 1.00 0.00
Lower Ground Floor Sqm 1.00 0.00
Mezzanine Floor Sqm 1.00 0.00
Ground Floor Sqm 1.00 0.00
First Floor Sqm 1.00 0.00
Second Floor Sqm 1.00 0.00
Third Floor Sqm 1.00 0.00
Fourth Floor Sqm 1.00 0.00
Total Sqm 0.00 0.00
9.5 S.S CLADDING CODE-A11-01 & 5/A11-01
Ground Floor Sqm 35.20 1.00 35.20
Total Sqm 35.20 37.00
9.6 WET CLADDING CODE-A11-01 & 6/A11-01
Ground Floor Sqm 12.16 1.00 12.16
Total Sqm 12.16 13.00
10 FLASHING TYPE
10.1 FLASHING TYPE 1 CODE-A11-01 & 5/A11-01
Basement Floor Sqm 0.00 1.00 0.00
Lower Ground Floor Sqm 0.00 1.00 0.00
Mezzanine Floor Sqm 0.00 1.00 0.00
Ground Floor Sqm 0.00 1.00 0.00
First Floor Sqm 0.00 1.00 0.00
Second Floor Sqm 0.00 1.00 0.00
Third Floor Sqm 0.00 1.00 0.00
Fourth Floor Sqm 0.00 1.00 0.00
Total Sqm 0.00 0.00
10.2 FLASHING TYPE 2 CODE-A11-01 & 6/A11-01
Ground Floor Rmt 100.28 1.00 100.28
Total Rmt 100.28 106.00
10.3 FLASHING TYPE 3 CODE-A11-01 & 7/A11-01
Ground Floor Rmt 140.42 1.00 140.42
Total Rmt 140.42 148.00
10.4 FLASHING TYPE 4 CODE-A11-01 & 7/A11-01
Basement Floor Sqm 1.00 0.00
Lower Ground Floor Sqm 1.00 0.00
Mezzanine Floor Sqm 1.00 0.00
Ground Floor Sqm 1.00 0.00
First Floor Sqm 1.00 0.00
Second Floor Sqm 1.00 0.00
Third Floor Sqm 1.00 0.00
Fourth Floor Sqm 1.00 0.00
Total Sqm 0.00 0.00
11 ROOF LEVEL FINISH
11.1 LOOSE GRAVEL STONE CODE-A12-09 & 15/A14-01
Basement Floor Sqm 1.00 0.00
Lower Ground Floor Sqm 1.00 0.00
Mezzanine Floor Sqm 1.00 0.00
Ground Floor Sqm 442.77 1.00 442.77
First Floor Sqm 1.00 0.00
Second Floor Sqm 1.00 0.00
Third Floor Sqm 1.00 0.00
Fourth Floor Sqm 1.00 0.00
Total Sqm 442.77 465.00
11.2 GREEN ROOF CODE-A12-09 & 15/A14-01
Basement Floor Sqm 1.00 0.00
Lower Ground Floor Sqm 1.00 0.00
Mezzanine Floor Sqm 1.00 0.00
Ground Floor Sqm 1.00 0.00
First Floor Sqm 1.00 0.00
Second Floor Sqm 1.00 0.00
Third Floor Sqm 1.00 0.00
Fourth Floor Sqm 1.00 0.00
Total Sqm 0.00 0.00
11.3 WOODEN DECKING CODE-A12-09 & 15/A14-01
Basement Floor Sqm 1.00 0.00
Lower Ground Floor Sqm 1.00 0.00
Mezzanine Floor Sqm 1.00 0.00
Ground Floor Sqm 1.00 0.00
First Floor Sqm 1.00 0.00
Second Floor Sqm 1.00 0.00
Third Floor Sqm 1.00 0.00
Fourth Floor Sqm 1.00 0.00
Total Sqm 0.00 0.00
11.4 ZINC ROOFING CODE-A12-09 & 15/A14-01
Basement Floor Sqm 1.00 0.00
Lower Ground Floor Sqm 1.00 0.00
Mezzanine Floor Sqm 1.00 0.00
Ground Floor Sqm 1.00 0.00
First Floor Sqm 1.00 0.00
Second Floor Sqm 1.00 0.00
Third Floor Sqm 1.00 0.00
Fourth Floor Sqm 1.00 0.00
Total Sqm 0.00 0.00
11.5 KOTA STONE CODE-A12-09 & 4/A14-01
Basement Floor Sqm 1.00 0.00
Lower Ground Floor Sqm 1.00 0.00
Mezzanine Floor Sqm 1.00 0.00
Ground Floor Sqm 1.00 0.00
First Floor Sqm 1.00 0.00
Second Floor Sqm 1.00 0.00
Third Floor Sqm 1.00 0.00
Fourth Floor Sqm 1.00 0.00
Total Sqm 0.00 0.00
Basement Floor Sqm 1.00 0.00
Lower Ground Floor Sqm 1.00 0.00
Mezzanine Floor Sqm 1.00 0.00
Ground Floor Sqm 1.00 0.00
First Floor Sqm 1.00 0.00
Second Floor Sqm 1.00 0.00
Third Floor Sqm 1.00 0.00
Fourth Floor Sqm 1.00 0.00
Total Sqm 0.00 0.00
Ground Floor Nos 2.00 1.00 2.00
Total Nos 2.00 2.00
Ground Floor Nos 2.00 1.00 2.00
Total Nos 2.00 2.00
2 URINAL PARTITION
Ground Floor Sqm 0.30 1.00 0.30
Total Sqm 0.30 1.00
13 WATERPROOFING BELOW GROUND LEVEL
13.1 1.2 mm HDPE MEMBRANE PRESSURE SENSITIVE ADHESIVE (Below Footing)
Basement level 1.0 1043.05 1.00 1043.05
13.2 1.2MM CROSS LAMINATED SBS MODIFIED MEMBRANE + 8MM THK HDPE PROTECTION BOARD
Basement level 1.0 1006.50 1.00 1006.50
13.3 1.2 mm HDPE MEMBRANE PRESSURE SENSITIVE ADHESIVE (below grade slab)
Basement level 1.0 171.55 1.00 171.55
15.12 GRANITE COUNTER
Ground floor Sqm 2.84 1.00 2.84
Total Sqm 2.84 3.00
15.12 FACIA - GRANITE
Ground Floor Rmt 5.33 1.00 5.33
Total Rmt 5.33 6.00
15.12 SINK NUMBER
Ground Floor Nos 5.00 1.00 5.00
Total Nos 5.00 5.00
14 COPING FINISH
14.1 COPING 1 CODE-A12-08 & 4/A11-01
Ground Floor Sqm 0.00 1.00 0.00
Total Sqm 0.00 0.00
14.2 COPING 2 CODE-A12-08 & 1/A11-01
Ground Floor Sqm 38.99 1.00 38.99
Total Sqm 38.99 41.00
14.3 COPING 3 CODE-A12-08 & 2/A11-01
Ground Floor Sqm 0.00 1.00 0.00
Total Sqm 0.00 0.00
14.4 COPING 4 CODE-A12-08 & 3/A11-01
Ground Floor Sqm 0.00 1.00 0.00
Total Sqm 0.00 0.00
14.6 COPING 5 CODE-A12-08 & 6/A11-01
Ground Floor Sqm 32.43 1.00 32.43
Total Sqm 32.43 35.00
GRANITE COUNTER Cum 2.84 0.075 0.21
25MM THICK STEEL GREY GRANITE FLOORING Cum 32.23 0.075 2.42
Total Cum 2.63 3.00
@ COVERED WALKWAY ROOF
Ground Floor Sqm 450.83 1.00 450.83
Total Sqm 450.83 474.00
SuPr ENGINEERING CONSULTANTS 307, SIDDHARTH UPSCALE, VASNA ROAD VADODARA-390007 TEL- 0265-3149701 MEASUREMENT
PROJECT : GUJARAT VANDANA MUSEUM, GUJARAT
VADODARA ARCHITECT : OPOLIS
DATE : 05-09-25 CLIENT : DIRECTORATE OF ARCHEOLOGY AND MUSEUMS, G.O.G
PREPARED BY : MANDIPSINH CHECKED BY :
SR.NO. PARTICULARS NO. L B D QTY.
2.6 300MM THICK AAC BLOCK MASONRY CODE-A13-01 & 1/A13-08
Ground Level Plan
(Location : Ticketing Pavllion)
Drg Title : GVM_A4_DETAILES PLAN_10-09-25
Drg Date : 11-09-2025
TICKETING PAVLLION
Tick counter toilet 1.0 2.03 0.30 3.50 2.13
16 MAIN ENTRY SECURITY
2.4 200MM THICK AAC BLOCK MASONRY CODE-A13-01 & 1/A13-08
Ground Level Plan
(Location : Ticketing Pavllion)
Drg Title : GVM_A4_DETAILES PLAN_10-09-25
Drg Date : 11-09-2025
13 TICKETING PAVLLION
Tick window wall 1.0 2.73 3.50 9.54
Parapet Wall 2.0 4.97 0.20 1.99
14 TOILET PAVILLIAN
Female Toilet 1.0 3.40 3.25 11.05
Male Toilet 1.0 5.90 3.25 19.17
Parapet Wall 2.0 3.40 0.20 1.36
15 STAFF /SERVICE SECURITY
Parapet wall 2.0 6.05 0.20 2.42
16 MAIN ENTRY SECURITY
Parapet wall 2.0 2.78 0.20 1.11
17 EXIT SECURITY
Parapet wall 2.0 5.40 0.20 2.16
17 FIRE TENDER SECURITY
Parapet wall 2.0 5.85 0.20 2.34
4.1 150 MM THICK AAC BLOCK MASONRY CODE-01A13-08
Female Toilet 1.0 1.83 3.25 5.93
INTERNAL PLASTER
Ground Level Plan
Drg Title : GVM_A4_DETAILES PLAN_10-09-25
Drg Date : 11-09-2025
13 TICKETING PAVLLION
TICK COUNTER WALL 1.0 16.32 4.00 65.28
Add Of jambs & soffits 1.0 5.15 0.20 1.03
15 STAFF /SERVICE SECURITY
16 MAIN ENTRY SECURITY
17 EXIT SECURITY
17 FIRE TENDER SECURITY
CEILING PLASTER
Ground Level Plan
Drg Title : GVM_A4_DETAILES PLAN_10-09-25
Drg Date : 11-09-2025
TICKETING PAVLLION
Cloak rm 1.0 31.66 p-area 31.66
Ticketing Counter 1.0 11.53 p-area 11.53
TOILET PAVILLIAN
Female Toilet 1.0 13.92 p-area 13.92
Male Toilet 1.0 16.88 p-area 16.88
STAFF /SERVICE SECURITY 1.0 3.81 2.46 9.37
MAIN ENTRY SECURITY 1.0 2.05 1.60 3.27
FIRE TENDER SECURITY
Ground Level Plan
Drg Title : GVM_A4_DETAILES PLAN_10-09-25
Drg Date : 11-09-2025
TICKETING PAVLLION
TOILET PAVILLIAN
Female Toilet 1.0 19.43 P-L 2.95 57.32
Male Toilet 1.0 22.14 2.95 65.30
Ground Level Plan
Drg Title : GVM_A4_DETAILES PLAN_10-09-25
Drg Date : 11-09-2025
TICKETING PAVLLION 2.0 4.38 4.00 35.04
TOILET PAVILLIAN
EXTERNAL PLASTER
Ground Level Plan
Drg Title : GVM_A4_DETAILES PLAN_10-09-25
Drg Date : 11-09-2025
13 TICKETING PAVLLION
CLOAK RM 1.0 34.35 P-line 4.30 147.69
Pump room 1.0 16.60 P-line 4.30 71.38
TIK COUNTER 1.0 20.70 4.30 89.01
15 STAFF /SERVICE SECURITY
16 MAIN ENTRY SECURITY
17 EXIT SECURITY
17 FIRE TENDER SECURITY
TOILET PAVILLIAN
Female Toilet 1.0 19.32 P-L 3.53 68.10
Male Toilet 1.0 27.30 3.53 96.24
CHEMICAL WATERPROOFING
Ground Level Plan
Drg Title : GVM_A4_DETAILES PLAN_10-09-25
Drg Date : 11-09-2025
TICKETING PAVLLION
TOILET PAVILLIAN
Female Toilet 1.0 13.92 p-area 13.92
Male Toilet 1.0 16.88 p-area 16.88
TICKETING PAVLLION
TOILET PAVILLIAN
Female Toilet 1.0 19.43 P-L 1.20 23.32
Male Toilet 1.0 22.14 1.20 26.56
Ground Level Plan
Drg Title : GVM_A4_DETAILES PLAN_10-09-25
Drg Date : 11-09-2025
TICKETING PAVLLION
TOILET PAVILLIAN
Female Toilet 1.0 13.92 p-area 0.30 4.18
Male Toilet 1.0 16.88 p-area 0.30 5.06
TERRACE WATERPROOFING
Ground Level Plan
Drg Title : GVM_A4_DETAILES PLAN_10-09-25
Drg Date : 11-09-2025
TICKETING PAVLLION
Cloak rm 1.0 31.66 p-area 31.66
Ticketing Counter 1.0 11.53 p-area 11.53
TOILET PAVILLIAN
Female Toilet 1.0 13.92 p-area 13.92
Male Toilet 1.0 16.88 p-area 16.88
STAFF /SERVICE SECURITY 1.0 3.81 2.46 9.37
MAIN ENTRY SECURITY 1.0 2.05 1.60 3.27
FIRE TENDER SECURITY
5 FLOORING WORK
5.9 25MM THICK KOTA STONE FLOORING CODE-A12-04 & 4/A14-01
Ground Level Plan
(Location : Ticketing Pavllion)
Drg Title : GVM_A4_DETAILES PLAN_10-09-25
Drg Date : 11-09-2025
Ticketing Pavllion 1.0 33.71 P-area 33.71
Ground Level Plan
(Location : Staff/Service Security)
Drg Title : GVM_A4_DETAILES PLAN_10-09-25
Drg Date : 11-09-2025
Staff Office 1.0 9.43 9.43
Ground Level Plan
(Location : Main Entry Security)
Drg Title : GVM_A4_DETAILES PLAN_10-09-25
Drg Date : 11-09-2025
Ground Level Plan
(Location : Exit Security )
Drg Title : GVM_A4_DETAILES PLAN_10-09-25
Drg Date : 11-09-2025
Ground Level Plan
(Location : Fire Tender Security )
Drg Title : GVM_A4_DETAILES PLAN_10-09-25
Drg Date : 11-09-2025
5.5 25MM THICK STEEL GREY GRANITE FLOORING CODE-A12-04 & 1/A14-01
Ground Level Plan
(Location : Toilet Pavillion)
Drg Title : 18-09-25_GVM_A1..int.Ceiling
Drg Date : 11-09-2025
Toilet Pavillion 1.0 18.56 18.56
5.14 10 MM THICK VITRIFIED TILES FLOORING CODE-A12-04 & 7/A14-01
Ground Level Plan
(Location : Tick Pavilian)
Drg Title : 18-09-25_GVM_A1..int.Ceiling
Drg Date : 11-09-2025
Tick Pavilian 1.0 18.56 18.56
6 WALL FINISH WORK
6.7 VITRIFIED TILES CLADDING DRG CODE- A12-05 REF : 8/A14-02
Ground Level Plan
(Location : Toilet Pavllion)
Drg Title : 18-09-25_GVM_A1..int.Ceiling
Drg Date : 11-09-2025
Toilet Pavilian 1.0 22.14 2.85 63.09
Toilet Pavilian 1.0 19.43 2.85 55.38
6.11 GYPSUM PLASTER + PAINT DRG CODE- A12-05 REF : 10/A14-02
Ground Level Plan
(Location : Ticketing Pavllion)
Drg Title : 18-09-25_GVM_A1..int.Ceiling
Drg Date : 11-09-2025
Ticketing Pavllion
Service Security
Main Entry security
Fire Tender Security
6.16 PLASTER FINISH DRG CODE- A12-05 REF : 15/A14-02
Ground Level Plan
(Location : Ticketing Pavllion)
Drg Title : 18-09-25_GVM_A1..int.Ceiling
Drg Date : 11-09-2025
Ticketing Pavllion 2.0 4.40 3.95 34.76
Toilet Pavilian 2.0 1.63 2.85 9.26
6.4 MANDANA STONE-3 CLADDING DRG CODE- A12-05 REF : 6/A14-02
Ground Level Plan
Drg Title : 18-09-25_GVM_A1..int.Ceiling
Drg Date : 11-09-2025
TICK COUNTER WALL 1.0 16.32 4.00 65.28
6.10 VITRIFIED TILES-2 CLADDING DRG CODE- A12-05 REF : 8/A14-02
Ground Level Plan
Drg Title : 18-09-25_GVM_A1..int.Ceiling
Drg Date : 11-09-2025
TICKETING PAVILLION 2.0 2.50 4.00 20.00
6 SKIRTING WORK
6.3 KOTA STONE SKIRTING CODE-A12-06 & 1/A14-03
Ground Level Plan
(Location : Ticketing Pavllion)
Drg Title : 18-09-25_GVM_A1..int.Ceiling
Drg Date : 11-09-2025
Ticketing Pavllion 1.0 5.02 5.02
6.3 KOTA STONE SKIRTING CODE-A12-06 & 1/A14-03
Ground Level Plan
(Location : Staff/Service Security)
Drg Title : 18-09-25_GVM_A1..int.Ceiling
Drg Date : 11-09-2025
Staff Office 1.0 10.73 10.73
6.3 KOTA STONE SKIRTING CODE-A12-06 & 1/A14-03
Ground Level Plan
(Location : Main Entry Security)
Drg Title : 18-09-25_GVM_A1..int.Ceiling
Drg Date : 11-09-2025
6.3 KOTA STONE SKIRTING CODE-A12-06 & 1/A14-03
Ground Level Plan
(Location : Exit Security )
Drg Title : 18-09-25_GVM_A1..int.Ceiling
Drg Date : 11-09-2025
6.3 KOTA STONE SKIRTING CODE-A12-06 & 1/A14-03
Ground Level Plan
(Location : Fire Tender Security )
Drg Title : 18-09-25_GVM_A1..int.Ceiling
Drg Date : 11-09-2025
8 FALSE CEILING WORK
8.2 ALUMINUM PANELS CODE-A12-07 & 4/A14-04
Ground Level Plan
(Location : Ticketing Pavllion)
Drg Title : 18-09-25_GVM_A1..int.Ceiling
Drg Date : 11-09-2025
Ticketing Pavllion 1.0 390.74 P-area 390.74
Ground Level Plan
(Location : Toilet Pavillion)
Drg Title : GVM_A4_DETAILED PLAN
Drg Date : 11-09-2025
Toilet Pavllion 1.0 18.59 P-area 18.59
8.9 MINERAL FIBRE GRID CEILING 600X600 CODE-A12-07 & 2/A14-04
Toilet Pavllion 1.0 13.68 P-area 13.68
Toilet Pavllion 1.0 18.56 P-area 18.56
8.10 GYPSUM + PAINT CODE-A12-07 & 5/A14-04
Ground Level Plan
(Location : Ticketing Pavllion)
Drg Title : 18-09-25_GVM_A1..int.Ceiling
Drg Date : 11-09-2025
Ticketing Pavllion 1.0 32.00 P-area 32.00
Ticketing Pavllion 1.0 16.06 P-area 16.06
8.13 PLASTER + PAINT CODE-A12-07 & 5/A14-04
Ground Level Plan
(Location : Main Entry Security,Exit Security,Fire Security)
Drg Title : 18-09-25_GVM_A1..int.Ceiling
Drg Date : 11-09-2025
Main Entry Security 1.0 13.52 P-area 13.52
Exit Security 1.0 9.77 P-area 9.77
Fire Tender Security 1.0 7.05 P-area 7.05
Staff Security 1.0 9.59 P-area 9.59
Ground Level Plan
(Location : Toilet)
Drg Title : 18-09-25_GVM_A1..int.Ceiling
Drg Date : 11-09-2025
L-Shape 1.0 1.00
L-Shape 1.0 1.00
Ground Level Plan
(Location : Toilet)
Drg Title : 18-09-25_GVM_A1..int.Ceiling
Drg Date : 11-09-2025
I-Shape 1.0 1.00
I-Shape 1.0 1.00
2 URINAL PARTITION
Ground Level Plan
(Location : Toilet)
Drg Title : 18-09-25_GVM_A1..int.Ceiling
Drg Date : 11-09-2025
9 PARAPET FINISH
9.2 1SIDE STONE CLADDING CODE-A11-01 & 1/A11-01
Ground Level Plan
Drg Title : 18-09-25_GVM_A1..int.Ceiling
Drg Date : 11-09-2025
Toilet pavillion 2.0 3.30 0.49 3.23
SERVICE SECURITY CABIN
EXIT SECURITY 1.0 22.60 0.49 11.07
FIRE TENDER SECURITY 1.0 16.93 0.49 8.30
9.5 S.S CLADDING CODE-A11-01 & 5/A11-01
Ground Level Plan
Drg Title : 18-09-25_GVM_A1..int.Ceiling
Drg Date : 11-09-2025
TICKETING PLAZA
9.6 WET CLADDING CODE-A11-01 & 6/A11-01
Ground Level Plan
Drg Title : 18-09-25_GVM_A1..int.Ceiling
Drg Date : 11-09-2025
Toilet pavillion
Main Entry Security
10 FLASHING TYPE
10.2 FLASHING TYPE 2 CODE-A11-01 & 6/A11-01
Ground Level Plan
Drg Title : 18-09-25_GVM_A1..int.Ceiling
Drg Date : 11-09-2025
TICKETING PLAZA
10.3 FLASHING TYPE 3 CODE-A11-01 & 7/A11-01
Ground Level Plan
Drg Title : 18-09-25_GVM_A1..int.Ceiling
Drg Date : 11-09-2025
Toilet pavillion 1.0 38.29 38.29
TICKETING PLAZA
Main Entry Security 1.0 19.30 19.30
EXIT SECURITY 1.0 19.96 19.96
FIRE TENDER SECURITY 1.0 15.33 15.33
11.1 LOOSE GRAVEL STONE CODE-A12-09 & 15/A14-01
Ground Level Plan
Drg Title : 18-09-25_GVM_A1..int.Ceiling
Drg Date : 11-09-2025
Toilet pavillion 1.0 47.43 47.43
TICKETING PLAZA
Main Entry Security 1.0 21.57 21.57
EXIT SECURITY 1.0 26.29 26.29
FIRE TENDER SECURITY 1.0 13.36 13.36
13 WATERPROOFING BELOW GROUND LEVEL
13.1 1.2 mm HDPE MEMBRANE PRESSURE SENSITIVE ADHESIVE (Below Footing)
Drg Title : A12-14A,B,C- WATERPROOFING DIAGRAM
Drg Date : 01-04-2026
Staff /Service Security
footing area 1.0 64.01 64.01
on footing vertical 1.0 40.70 0.80 32.56
footing area 1.0 11.52 11.52
on footing vertical 1.0 13.60 0.80 10.88
footing area 1.0 209.28 209.28
on footing vertical 1.0 80.60 0.80 64.48
Boundary side Below footing area 4.0 9.79 39.16
on footing vertical 4.0 12.52 0.80 40.06
Toilet pavilion
footing area 5.0 12.00 60.00
on footing vertical 5.0 13.90 0.80 55.60
Main entry security 1.0 63.36 63.36
on footing vertical 1.0 31.85 0.80 25.48
Fire tender secuirty tender
Footing area 1.0 46.87 46.87
on footing vertical 1.0 28.10 0.80 22.48
Staff Secuirty cabin 1.0 66.67 66.67
on footing vertical 1.0 42.50 0.80 34.00
13.2 1.2MM CROSS LAMINATED SBS MODIFIED MEMBRANE + 8MM THK HDPE PROTECTION BOARD
Drg Title : A12-14A,B,C- WATERPROOFING DIAGRAM
Drg Date : 01-04-2026
VERTICAL COLUMNS IN RAFT/ FOOTINGS
Staff /Service Security
Ded of wall area -4.0 0.32 -1.28
Footing area 1.0 2.40 3.95 9.48
on footing vertical 1.0 13.60 13.60
Ded of wall area -1.0 0.32 -0.32
On Floor 4.0 9.79 39.16
Ded of wall area -4.0 0.28 -1.10
Toilet pavilion
Ded of wall area -5.0 0.69 -3.45
Main entry security
Fire tender secuirty tender
Footing area 1.0 46.87 46.87
Ded of wall area -2.0 0.16 -0.32
Staff Secuirty cabin
Ded of wall area -7.0 0.34 -2.38
13.3 1.2 mm HDPE MEMBRANE PRESSURE SENSITIVE ADHESIVE (below grade slab)
Drg Title : A12-14A,B,C- WATERPROOFING DIAGRAM
Drg Date : 01-04-2026
Staff /Service Security
Grade slab area 1.0 27.56 P-area 27.56
Toilet pavilion
Grade slab area 1.0 62.78 P-area 62.78
Main entry security
Grade slab area 1.0 23.67 P-area 23.67
Fire tender secuirty tender
Grade slab area 1.0 13.10 P-area 13.10
Staff Secuirty cabin
Grade slab area 1.0 30.24 P-area 30.24
15.13 GRANITE COUNTER
Lower ground floor
(Location : ELIPTICAL )
Drg Title : 2025-09-18_GVM_A12-12-RAILING DIAGRAM
Drg Date : 19-09-2025
FACIA - GRANITE
(Location : ELIPTICAL )
Drg Title : 2025-09-18_GVM_A12-12-RAILING DIAGRAM
Drg Date : 19-09-2025
M.Toilet 1.0 1.92 1.92
F.Toilet 1.0 1.91 1.91
(Location : ELIPTICAL )
Drg Title : 2025-09-18_GVM_A12-12-RAILING DIAGRAM
Drg Date : 19-09-2025
Toilet , 1.0 1.00
M.Toilet 2.0 2.00
F.Toilet 2.0 2.00
14 COPING FINISH
14.2 COPING 2 CODE-A11-01 & 1/A11-01
Ground Level Plan
Drg Title : 18-09-25_GVM_A1..int.Ceiling
Drg Date : 11-09-2025
Toilet pavillion 2.0 3.30 0.49 3.23
SERVICE SECURITY CABIN
EXIT SECURITY 1.0 22.60 0.49 11.07
FIRE TENDER SECURITY 1.0 16.93 0.49 8.30
14.5 COPING 5 CODE-A11-01 & 6/A11-01
Ground Level Plan
Drg Title : 18-09-25_GVM_A1..int.Ceiling
Drg Date : 11-09-2025
Toilet pavillion
Main Entry Security
@ COVERED WALKWAY ROOF
Ground Level Plan
Drg Title : 18-09-25_GVM_A1..int.Ceiling
Drg Date : 11-09-2025
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
RAW_HTML
01 GVM_Schedule 2_Scope of Work.pdf
2026_07.06 Vol II CMA Contract GVM.pdf
Schedule 3 Annex 2- Tender Drawings.pdf
GVM_Blank BOQ_for Bidders.xlsx
XLSX
2026.07.06_GVM CMA RFP_Vol I.pdf
Download all tender documents and submit your bid