| Sl No | Description | Qty | Unit | JAIN BUILDER L3 | Jeet Construction L5 | VIJAY CONSTRUCTIONS L2 | Kurian And Varghese L4 | M/s Matadeen Ramchandra Agarwal L8 | AMIT ASSOCIATES L6 | LUMOS INFRA PVT LTD L7 | ranjit kumar biswal L1 |
|---|---|---|---|---|---|---|---|---|---|---|---|
| 1.00 | Total amount of Sch 'A' Part-I : (Buildings/ Structures) | 1 | LUMPSUM | 5,16,99,999 ₹5.2 Cr | 8,02,56,525 ₹8.0 Cr | 7,07,32,508 ₹7.1 Cr | 7,72,04,866 ₹7.7 Cr | 10,80,00,000 ₹10.8 Cr | 8,08,00,000 ₹8.1 Cr | 7,99,96,522 ₹8.0 Cr | 8,69,87,250 ₹8.7 Cr |
| 2.00 | Total amount of Sch 'A' Part-II : (Earthwork, Excavation, Site Clearance & Site Development) | 1 | LUMPSUM | 8,80,660 ₹8.8 L | 17,13,566 ₹17.1 L | 18,13,822 ₹18.1 L | 16,87,609 ₹16.9 L | 21,00,000 ₹21 L | 18,13,822.78 ₹18.1 L | 19,12,969 ₹19.1 L | 12,69,675.95 ₹12.7 L |
| 3.00 | Total amount of Sch 'A' Part-III : (Internal Water Supply) | 1 | LUMPSUM | 2,00,000 ₹2 L | 1,95,565 ₹2.0 L | 2,19,207 ₹2.2 L | 1,92,458 ₹1.9 L | 1,99,998 ₹2.0 L | 1,88,500 ₹1.9 L | 1,82,635 ₹1.8 L | 2,08,769.98 ₹2.1 L |
| 4.00 | Total amount of Sch 'A' Part-IV : (Internal Electric Supply) | 1 | LUMPSUM | 22,00,000 ₹22 L | 45,25,155 ₹45.3 L | 43,42,182 ₹43.4 L | 40,41,388 ₹40.4 L | 35,10,000 ₹35.1 L | 46,83,600 ₹46.8 L | 43,56,735 ₹43.6 L | 36,90,854.7 ₹36.9 L |
| 5.00 | Total amount of Sch 'A' Part-V : (External Water Supply) | 1 | LUMPSUM | 2,00,000 ₹2 L | 3,00,025 ₹3.0 L | 3,14,395 ₹3.1 L | 2,90,653 ₹2.9 L | 3,15,000 ₹3.1 L | 2,99,424 ₹3.0 L | 3,02,568 ₹3.0 L | 2,99,424 ₹3.0 L |
| 6.00 | Total amount of Sch 'A' Part- VI : (External Electric Supply) | 1 | LUMPSUM | 11,00,000 ₹11 L | 19,25,652 ₹19.3 L | 17,91,350 ₹17.9 L | 17,79,034 ₹17.8 L | 18,00,000 ₹18 L | 18,32,000 ₹18.3 L | 15,42,855 ₹15.4 L | 16,48,042.18 ₹16.5 L |
| 7.00 | Total amount of Sch 'A' Part-VII : (Lightning Protection) | 1 | LUMPSUM | 1,50,000 ₹1.5 L | 1,85,256 ₹1.9 L | 2,19,612 ₹2.2 L | 2,05,629 ₹2.1 L | 2,25,000 ₹2.3 L | 2,10,300 ₹2.1 L | 2,16,543 ₹2.2 L | 2,19,612.8 ₹2.2 L |
| 8.00 | Total amount of Sch 'A' Part-VIII : (Area Drainage) | 1 | LUMPSUM | 4,00,000 ₹4 L | 6,00,025 ₹6.0 L | 6,21,669 ₹6.2 L | 6,35,432 ₹6.4 L | 8,10,000 ₹8.1 L | 6,21,669.34 ₹6.2 L | 7,89,521 ₹7.9 L | 6,21,669.34 ₹6.2 L |
| 9.00 | Total amount of Sch 'A' Part-IX : (Sewage Disposal) | 1 | LUMPSUM | 90,000 ₹90,000 | 1,12,565 ₹1.1 L | 1,35,842 ₹1.4 L | 1,43,007 ₹1.4 L | 1,75,000 ₹1.8 L | 1,20,500 ₹1.2 L | 1,65,732 ₹1.7 L | 1,35,842.97 ₹1.4 L |
| 10.00 | Total amount of Sch 'A' Part-X : (Road/ Path/ Hardstanding) | 1 | LUMPSUM | 24,00,000 ₹24 L | 25,25,266 ₹25.3 L | 28,08,042 ₹28.1 L | 26,75,679 ₹26.8 L | 33,35,000 ₹33.4 L | 26,55,000 ₹26.6 L | 31,68,653 ₹31.7 L | 26,67,640.51 ₹26.7 L |
Updated dates
Tender Value
₹29.4 Cr
EMD Value
₹15 L
Closing Date
31 Jan 2026, 6:00 pmClosed
CE (NW) KOCHI
CHIEF ENGINEER NAVAL WORKS KOCHI MILITARY ENGINEER SERVICE NAVAL BASE POST KATARIBAGH KOCHI-682004
PROVISION OF DEFICIENT TRAINING AND ADMINISTRATIVE INFRASTRUCTURE FOR HQST AT NAVAL BASE KOCHI
2025_MES_743006_1
891103
Open Tender
Civil Works
900 days
KOCHI
Please refer Tender documents.
8 documents required · 8 mandatory
₹3,000
GE(P)(NW) KOCHI
₹15 L
5 Mar 2026
4 Dec 2025
2 Feb 2026
4 Dec 2025
31 Jan 2026
17 Jan 2026
4 Dec 2025 - 24 Dec 2025
Total amount of Sch 'A' Part-I : (Buildings/ Structures)
OUTGOING (a) MCB 16 Amps rating 4 pole - 02 Nos( For G+7 and one spare) (b) DOL starter for 05 HP Fresh water supply pump- 2Nos (c)Digital volt meter 0-500 Volts-01 (d)Digital Ampere meter 0-100 Amps with and including CTs (e) Neon phase indicating lamp(Set of three)-01 Nos (f) Stenceling of pannel board including marking of distribuitions
(ii) ALTERNATOR: Brushless AC alternator, 3 phase, 415 Volts, 4 wire rated for output of 50 KW (62.5 KVA) minimum power factort 0.80, 1500 RPM, IP 23 ptotection class enclosure, insulation class 'H', salient pole, revolving field, single bearing, automatic voltage regulator coupled through flexible coupling with and match the above engine. (iii) BASE PLATE:- Made of structural steel as per manufacturers recommended design/specifications.
Supply and installation of HT 11 KV, 630 Amps, 21 KA Motor operated compact outdoor both side extensible, non drawout type (+C+) (01 No. Load break Switch (OD) incomer SAFEPLUS Compact gas insulated for existing Ring Main Unit (RMU), All live parts enclosed in a welded stainless steel tank of IP 67 class of protection including coupling accessories with battery and battery charger all as specified and as directed. The RMU will be installed at existing 'FOST' open sub station where HT supply tapping point. Make: Crompton.
Supply, installation,commissioning of Watercooler with inbuilt purifier HIMA 7 NHC (Ozonisation Technology) dispencing capacity 125ltr/hr fully stainless steel, electric driven single phase having approx storage 40 ltrs and nominal cooling 40 ltrs single, & 4 ltr Hot water phase 230 V AC power supply with all connecting accessories including PCC foundation complete all as specified and directed by engineer in charge.
Total amount of Sch 'A' Part-II : (Earthwork, Excavation, Site Clearance & Site Development)
Total amount of Sch 'A' Part-IV : (Internal Electric Supply)
M & L GI pipe light grade of size 40 mm under trench, floor or wall for protection of GI strip.
Total amount of Sch 'A' Part-III : (Internal Water Supply)
Total amount of Sch 'A' Part-VIII : (Area Drainage)
Total amount of Sch 'A' Part-IX : (Sewage Disposal)
Total amount of Sch 'A' Part-X : (Road/ Path/ Hardstanding)
Total amount of Sch 'A' Part-V : (External Water Supply)
Boring for cast in situ piles 500mm dia to 53m depth through any type of soil/ strata by DMC method using bentonite slurry including removal of bored materials out side MD land complete all as specified.
RCC M35 Design Mix as per IS- 456 with using 20mm graded stone aggregate as in pile cap and grade beam all as specified and as shown in drg.
RCC M35 Design Mix as per IS- 456 with using 20mm graded stone aggregate as in cast in situ bored pile of 500mm dia and 53m length/ all as specified and as shown in drg.
Providing TMT bars 10 mm dia and over, cut to length, bent to shape required incl cranking, bending, sprilly for hooping for columns etc for bored piles/grade beams/tie beams and pile caps complete all as specfied.
Providing TMT bars 5 mm dia and over but up to 10mm dia as in stirrups/helical stirrups for piles and binding with mild steel wire etc for grade beams, tie beams and bored piles complete all as specfied.
PCC (1:4:8) type D2 using 40mm graded stone aggregate for concrete layer below pile cap/grade beam and foundation complete all as specfied and as shown in drg.
M&L for form work to sides of pile cap, grade beams and tie beams for rough finished flat concrete surface as specified and as directed.
M & L precast cement concrete block masonry with solid blocks Type C1 1:3:6 (20mm garded aggregate) exc. 10cm in width and setting in cement mortar 1:6, complete all as specified and as directed.
Sch 'A' Part- XIV : (Miscellaneous B/R & E/M Items (BOQ) (Note : This schedule is not pre priced by MES and the pre priced rate indicated as "Rs. 0.00" under Col.5 signifies this fact only.)
S&F LT Cable route marker of Cast Iron type Circle 100 dia all as specified and as directed.
All as per item No 36 but for One Socket outlet, three/five pin, 5 Amp, same board controlled by one 5/6 amps one way switch complete all as specified and directed.
Supply and fix Tap off box with 63A,16KA, MCCB suitable for installation on 400A BBT system as per item No 58 all as specified and as directed.
OUTGOING (a) MCCB TPN 320 Amps 36 KA Thermal magnetic Release- For building panel incomer. (b) MCCB TPN 200 Amps , 25 KA Thermal magnetic Release - 03 Nos for (stand by supply panel, capacitor bank and spare) (e) Internal wiring of panel with stranded copper cable of suitable size (f) Neon phase indicating lamp(Set of three)-01 Nos (g) Stenceling of pannel board including marking of distribuitions
OUTGOING (a) MCCB 415 Volts, 125 A TPN,18KA - 02 Nos (for fire fighting panel and spare) (b) MCB 415 Volts 40 A TPN,18 KA - 05 Nos ( for 03 nos 13 passenger lift, 01 No fresh water pump panel and 1 spare) (c) MCB 415 Volts 25 A SPN - 02 No ( for aviation obstruction light,security light and stair case lightning) (d) Internal wiring of panel with stranded copper cable of suitable size (e) Neon phase indicating lamp(Set of three)-01 Nos (f) Stenceling of pannel board including marking of distribuitions
Supply, installing, testing and commissioning of electrically driven centrifugal Pump set as per specification, motor TEFC type, 2900 rpm, 420 V, 50 Hz, 3 ph, class 'F' insulation, IP 55 protection, not less than 5 HP, starting on suitable DOL/Star Delta starter. The pump shall be horizontal, end suction, top discharge. The pump shall have cast iron casing, cast iron/bronze impeller(as per manufacturer), carbon steel shaft with common base frame (fabricated mild steel channel frame or cast iron type) placed on RCC (1:2:4) including foundation bolts, nuts etc. complete with antivibrator pad as required capable of discharging not less than 450 LPM at 55 mtr head inclusive of suitable rated 3 ph starter as recommented by the manufacturer, PVC insulated copper cable connection from starter to the motor terminals all as specified and directed by the Engineer-in-charge. Make:- Kirloskar Brothers/ equaivalent.
Each Job
Point
Supply,spreading and levelling riddled soil as earth cushioning to UG cable by usinng IS sieve to seprate the composite/roots etc and refilling spreading in trenches as cushioning and rammed down to form a solid bed all as specified and directed at site. Note:- Punned thickness shall be measured and paid.
RCC septic tank designed for 50 users to carry sewage and sullage water, excavation in any type of soil, , PCC 1:4:8 below foundation, RCC M-30 Design Mix in Walls, Base Slab, Baffle walls and Roof slab including beams etc with Vent shaft, manhole opening with cover connection etc. complete with effective depth of 1.5meter and overall depth of 3 meter all as specified and as directed.
RCC septic tank designed for 100 users to carry sewage and sullage water, excavation in any type of soil, , PCC 1:4:8 below foundation, RCC M-30 Design Mix in Walls, Base Slab, Baffle walls and Roof slab including beams etc with Vent shaft, manhole opening with cover connection etc. complete with effective depth of 1.5meter and overall depth of 3 meter all as specified and as directed.
Soakage well 1.8 M dia X 3.0 M effective depth Soakage wells excavation, in any type of soil, foundation in PCC 1:3:6, walls of honey combed masonry with top ring of M25 concrete including intercepting chamber and screen chamber made of Brick masonary in CM, RCC cover slab in M25/ SFRC cover, interconnecting pipes of RCC/DWC complete filled with brick bats of size all as specified and as directed.
Sockage well 3 M dia and 1.2 M deep incl excavation any type of soil, PCC 1:3:6 foundation honey combbed PCC block wall M 25 topping incl intercepting chamber in cement mortar, RCC cover slab, interconnecting RCC pipe filled with brick bats etc all as shown on drg.
(b) The integral dimension of the lift car should be suitable size for the specified load and in accordance with the statutory requirements. (c) The inside car measurement shall be based on lift well dimensions shown on drawings forming part of the Contract. Each lift shall be complete with following accessories & fittings. (i) Double button with 7 segmental display at all floors. (ii) Car opening panel with micro stroke push button with 7 segment digital car position indicator, car direction indicator (iii) Fire exitingusher which provided at main lobby. (iv) Battery operated alarm bell and emergency lift with battery. (v) Voice Synthesizer (vi) Car Chime (vii) Provision of cross flow rectangular (low noise/mild air flow) fan-01 of approved make. (viii) S&F Decorative LED spot light (ix) Provn of emergency intercom system (car machine room-control system) (x) Oveload function, constant indication/buzzer. (xi) 5/15 A power socket & light point at every floor level in the hoist way. (xii) MS Ladder (xiii) 3 Phase power supply & earthing from machine room to all equipment. (xiv) Multi beam full length infra red door sensor (minimum of 32) (xv) Emegency landing device ELD (ARD) (xvi) Extra cores in travelling cable for customer smoke detectors. (xvii) Back ground music speakers.
Supply and lay pipe ductile Iron,flanged type including specials, Class "K-9", 150 mm (6") dia all as specified and as directed.
Supply and fix Automatic air release valve 50 mm dia suitable for domestic water with 50 mm gun metal stop valve complete all as specified and as directed.
Supply and fix Automatic air release valve 25 mm dia suitable for domestic water with 25 mm gun metal stop valve complete all as specified and as directed.
Supply and fix mild steel class 'C' diesel pump exhaust pipe 150 mm dia with one layer of 10 mm thick ceremic fiber rope insulation and including all fitting clamp/Structural steel supports complete all as specified and as directed.
Supply and fix foot valve conforming to IS 4038 150 mm (6") dia cast iron all as specified and as directed.
Supply and fix foot valve conforming to IS 4038 100 mm (4") dia cast iron all as specified and as directed.
Supply of Analog addressable type active loop repeater (Loop power/external power) Fire terminal with inbuilt turbo isolator, Backlit LCD Display 6 x40 characters display, having controls for reset, mute,accept, silence alarms and self test, with programmable free keys and duly approved by EN54/LPCB/VDS/FMall as specified and as directed.
LED Emergency exit signage luminaire lit up using regular main supply comes with a unique rechargeable battery capable of emergency backup upto 05 hours as specified and as directed.
LED Emergency escape lighting luminaire lit up using regular main supply comes with a unique rechargeable battery capable of emergency backup upto 05 hours as specified and as directed.
Supply, installation testing and commissioning of XLPE insulated PVC sheathed FRLS galvanised steel strip or wire (Heavy duty) electric cable with copper coductor of size 1.5 sq.mm, 2 core suitable for working pressure 1100 Volts to IS:7098 and drawn into PVC conduit pipe 20 mm all as specified and directed.
Earthing complete with Galvanized steel earth plate electrode of size 600mmX600mm, 6.00 mm thick buried directly in ground vertically to a depth not less than 2.25 metres below the normal ground level with top edge of the plate not less than 1.5m below normal GL and connected to galvanized earth wire 4 mm dia. by means of bolts, nuts, check nuts and washers of galvanized iron steel all as shown in Electrical Plate No.5 connecting to earthing test point, including necessary earth work in any type of soil, PCC earth chamber made in PCC 1:3:6 type C1 (using 20mm graded aggregate), common salt, charcoal, CI funnel, ea
rth pit cover in RCC 1:2:4 type B1 (using 20mm graded aggregates), with 8mm CTD bars @ 100mm c/c in both ways, including necessary form work including painting of earth value & name of earth pit on top of earth pit cover with handrail will be above checked or parking tiles complete including necessry test on completion all as specified and as directed. Note : The unit rate shall also include for excavation, earth work in hard/dense soil PCC (1:3:6) type C1 pit, RCC cover slab, GI funnel with 20 mm dia watering pipe, wire mesh, 15mm dia light grade GI protection pipe for earth lead etc., complete all as specified and as directed.
(iv) ACOUSTIC ENCLOSURE:- Sheet metal fabricated canopy type, silent enclosure, manufactured on CNC machines as per CPCB norms and shall be powder coated. The enclosure shall be designed for reducing the sound level to 75 DB at a distance of 1 mtr at 75% load under field condition and 70DB at 3 M from Gen Set when DG set is working at full load along with testing performance, labeling certification etc. as laid down in GSR No. 371(E) dt 17 May 2002. (i) Foundation/Plinth/Base shall be provided as per manufacturers recommendations, however minimum 0.50 M space should be available all around the set and height of plinth shall not be less than 0.50 M. (ii) Standard Diesel Engine tank of adequate capacity for running the Gen Set continuously for 12 hours including standard pvc pipes from tank to
Supply installation testing and commissioning of Addressable Control Module for Sounders / Strobes / Sounder cum Strobes. The control module shall provide DPDTcontact rated at 24v DC, 2A. The device shall have an LED which shall blink in normal state & get steady on activation to monitor the heath status of the device. Addressing shall be with user friendly rotary decimal switches. Module shall be supplied with mounting plate from OEM for ease of installation & maintenance. The module shall be EN 54 and FM approved. MAKE : NOTIFIER/ HONEYWELL/ EDWARDS/ SIEMENS
Supply,installation,testing and commissioning of Fire Alarm Sirens Electronic type horizontal single stage continous normal operation for atleast 50 minutes with sound level 65 DB to 120 DB measured at 1.5 Mtr with sound output variation of +5 DB, range upto 1000m complete all as specified and as directed by the Engineer-in-Charge. EN 54 Make:- Notifier/Morley/Cooper/Honeywel or equivalent in other approved make
Supply and provide reinforced rubber cotton synthetic fibre circular woven jacketed fire delivery hose 63mm dia treated aginst rot/ mystex having 38 Kg/cm² working pressure bearing IS-636 type 'A' 30 mtrs length with male and female coupling conforming to IS-903 for yard hydrant all as specified and as directed. Note :- Hoses shall be of synthetic fibre , circular woven jacketed, treated against rot, working pressure 12 Kg/cm². Burst pressure, 36 Kg/cm². Coupling shall be male and female parts, gunmetal, 63mm (2 ½") size, heavy quality bearing conforming to IS 903 with IS mark and TAC approval
Supply and fix aviation obstruction LED integral aviation light Comprising of aluminium housing and polycarbonate enclosure with timer switch and one 10A MCB SP 230 Volts fixed in a sheet metyal enclosure.,Contactor MO9 1NO + 1NC contactor, MS Framework all as specified and as directed.
Supply and fix MCB distribution board SP 2 Way, single phase 240 volt rated without bus bar complete all as specified and as directed by Engr-in-charge.
S&F GI metal flush boxes 2 module with modular white plate all as specified and as directed.
Supply and fix RJ 45 NCN/NUD socket 1 module with cover plate all as specified and as directed.
Supply and fix TV socket 1 module with cover plate all as specified and as directed.
M&L Rigid non metallic PVC conduit exclusive of boxes (junction/ terminal) but inclusive of all Tees, bends, elbows, reducers, bell mouth, bell tube ends and fixing accessories such as couplers, lock nuts, saddles, pipe hooks etc, dia of conduit 20mm ( Medium Grade) all as specified and as directed.
INCOMING (a) MCCB 415 Volts, TPN 125 Amps,4 P, 25 kA - 01 No (Incoming) (b) Digital volt meter 0-500 Volts-01 (c) Digital Ampere meter 0-100 Amps with and including CTs-01 No OUTGOING (a) MCB TPN 100 Amps 18 kA - 01 Nos (b) MCB TP 40 Amps 18 kA - 01 No (c) MCB SPN 25 Amps 10 kA - 01 No (d) Star Delta starter for 75 HP pump- 1Nos (e) DOL starter for 7.5 HP Jockey pump- 1Nos (f) Neon phase indicating lamp(Set of three)-01 Nos (g) Stenceling of pannel board including marking of distribuitions
M&L Rigid non metallic PVC conduit exclusive of boxes (junction/ terminal) but inclusive of all Tees, bends, elbows, reducers, bell mouth, bell tube ends and fixing accessories such as couplers, lock nuts, saddles, pipe hooks etc, dia of conduit 25mm (Medium Grade) all as specified and as directed.
Supply and Fixing Voltage stabliser for auto operation, single phase, naturally air cooled indoor type and designed for input variation between 170V to 280V with out voltage stablizer at 230 V with accuracy with in +/-2.5% and speed of correction 8 volts per second and of capacity 2.0KVA Capacity all as specified and as directed. Make: V-Guard or equivalent.
Supply and install hi wall split units indoor/outdoor complete with cordless remote control unit and with in built air ioniser and Plasma filter for better indoor air quality with minimum 5 star rating and EER 3.2.of capacity 1.5 TR with inverter compressor technology, R-32 refrigerent, anti dust filter, active carbon filter, anti microbial filter, anti viral filter and heavy duty cooling including provision of suitable bracket fixing arrangement, required copper pipe and insulation as per site requirement complete as specified and directed by Engr-in-charge.
Supply and install hi wall split units indoor/outdoor complete with cordless remote control unit and with in built air ioniser and Plasma filter for better indoor air quality with minimum 5 star rating and EER 3.2.of capacity 2 TR with inverter compressor technology, R-32 refrigerent, anti dust filter, active carbon filter, anti microbial filter, anti viral filter and heavy duty cooling including provision of suitable bracket fixing arrangement, required copper pipe and insulation as per site requirement complete as specified and directed by Engr-in-charge.
S&F hybrid solar security light with luminous efficacy 175 lum/Watt along with monocrystalline solar panel of peak wattage 35W, Lithium ferro phosphate type battery of capacity min 20Ah, battery voltage 12.8 V, charge controller MPPT type of wattage min 17W, fitting shall be made of pressure die cast aluminium housing with IP65 protection and impact resistance of IK 08 complete with and including wall mounted bracket fabricated out of 40mm GI pipe light grade bend to shape1.5 mtr long and two nos wall mounting clamps using 25x4mm thick MS strip bend to shape and welded with pipe to form solid structure and one run of 1sqmm PVC insulated multistranded copper conductor wire connecting PVC terminal to fitting all as specified and as directed.
Supply and fix Voltage stablizer for automatic operation, single phase naturally air cooled indoor type & designed for input variation between 170 V to 250V with output voltage stablized at 230Volts with accuracy of ±2.5% and of capacity 4KVA completed as specified and directed by Engr-in-Charge.
Supply and fix Unplasticised PVC pipes of pressure rating 10 kgf/cm2 fixed complete to walls, ceilings or in floors etc., alongwith supporting clamps/saddles completed as specified and directed by Engr -in-charge.
Supply,install, testing and commissioning 3 phase AC input 300 to 450V and output 3 phase phase AC output voltage 440 ±5% Volts UPS of capacity 60KVA with back up 15 to 30 minute including 1 year warrranty for UPS as per site requirement complete as specified and directed by Engr-in-charge.
Point wiring using approved colour coding as per IS (Red, Black and Green for single phase circuits), with multi-stranded copper conductor 1.5 Sq. mm nominal cross-sectional area, single core, PVC insulated and sheathed FRLS cable 1100 volts grade, ISI-694 marked including heavy duty PVC concealed conduit and conduit accessories concealed in wall/roof/floor etc, ISI marked including modular GI flush box of suitable size with inner and outer white plastic plate (Same make of approved switch and socket) including PVC insulated multi-stranded copper conductor 1.5 Sqmm nominal cross sectional area single core FRLS cable as earth continuity conductor to common earth and connecting to earth dolly for one light/ ceiling fan /exhaust fan/Bell point controlled by one 5/6 amps one way switch complete all as specified and directed.
Supply and installation of Battery 150AH 12 Volts for charging the UPS including 2 year warranty alongwith interlink connection with UPS and cables as per site requirement complete as specified and directed by Engr-in-charge.
Each set
(i) DIESEL ENGINE (Prime Mover): Diesel Engine 1500 RPM, direct injection, six cylinders, four stroke, confirming to ISO3046/BS5514, water cooled, natuarally turbo charged, capable of giving adequate BHP to drive alternator cap
Testing of piles (Routine load test) all as per IS for 600 mm dia including removing the testing equiptment from site after testing is complete all as specified.
able of delivering 50KW(62.5 KVA) at outdoor atmospheric conditions at palluruthy,kochi (Considering all derating factors prevailed in the area). Batteries 12/24 Volts and desired ampere hours (as per manufacturers recommendations), electric battery start, complete with fly wheel and all standard fittings and fixtures as per manufacturer and including suitable panel with tacho meter, lub oil temperature, pressure gauge and frequency meters. The engine shall have self starter, dynamo, FIP, oil pump, fuel electric control panel with mechanical governor (ECPG) and Engine protection system (Shut down, High water temperature, low lub oil, oil pressure, over speed etc. , recommented capacity of fuel tank and first filling of fuel and lub oil and other consumables etc.
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Tendernotice_1.pdf
PDF • 0.39 MB
Tender.pdf
Tender Documents • 1.79 MB
Prepriced_sch.pdf
Tender Documents • 0.33 MB
BOQ_832012.xls
BOQ • 8.15 MB
Download all tender documents and submit your bid