Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Tender Value
₹1.6 Cr
EMD Value
₹2.3 L
Closing Date
25 Apr 2025, 3:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
No
No
Single Packet System
Normal Tender
No
Not Applicable
Lowest to Highest
60 days
Expenditure
Capital (Works)
SIGNALPGT
15 conditions · 4 needing a document upload
Financial Eligibility Criteria: The tenderer must have minimum average annual contractual turnover of V/N or 'V' whichever is less; where V= Advertised value of the tender in crores of Rupees N= Number of years prescribed for completion of work for which bids have been invited. The average annual contractual turnover shall be calculated as an average of "total contractual payments" in the previous three financial years, as per the audited balance sheet. However, in case the balance sheet of the previous year is yet to be prepared/ audited, the audited balance sheet of the fourth previous year shall be considered for calculating average annual contractual turnover. The tenderers shall submit requisite information as per Annexure-VIB, along with copies of Audited Balance Sheets duly certified by the Chartered Accountant/ Certificate from Chartered Accountant duly supported by Audited Balance Sheet.
Technical Eligibility Criteria: (a) The tenderer must have successfully completed or substantially completed any of the following during last 07 (seven) years, ending last day of month previous to the one in which tender is invited: (1)Three similar works each costing not less than the amount equal to 30% of advertised value of the tender, or (2)Two similar works each costing not less than the amount equal to 40% of advertised value of the tender, or (3)One similar work each costing not less than the amount equal to 60% of advertised value of the tender. (b) (i) In case of tenders for composite works (e.g. works involving more than one distinct component, such as Civil Engineering works, S&T works, Electrical works, OHE works etc. and in the case of major bridges - substructure, superstructure etc.), tenderer must have successfully completed or substantially completed any one of the following categories of work(s) during last 07 (seven) years, ending last day of month previous to the one in which tender is invited: (i) Three similar works each costing not less than the amount equal to 30% of advertised value of each component of tender, or (ii) Two similar works each costing not less than the amount equal to 40% of advertised value of each component of tender, or (iii) One similar work each costing not less than the amount equal to 60% of advertised value of each component of tender.
Similar nature of work: - "Any telecom work involving commissioning of OFC or Quad cable or PA system or Coach guidance or IPIS or Arrival - departure boards or GPS clocks or WiFi or CCTV or exchange or Data connectivity works or IPMPLS".
Submission of 'Undertaking by the tenderer' in their offer that the equipment shall be procured from the RDSO approved/Development vendor list as per RDSO specification who have final approval certificate from RDSO on or before the date of opening of tender. Installation, testing and commissioning of equipment shall also be done from the same approved source including after sales support required during the warranty period.
7 conditions · 3 needing a document upload
Please enter the percentage of local content in the material being offered. Please enter 0 for fully imported items, and 100 for fully indigenous items. The definition and calculation of local content shall be in accordance with the Make in India policy as incorporated in the tender conditions.
Collection and transportation of materials from Railway stores depots of Divisions concerned shall be done by the tenderer.
The rates quoted by the tenderer should be inclusive of all taxes including GST.
The CAMC rates shown in the ireps portal are not the Railway assessed rates but shown only to fill the gap at the IREPS portal. The Bidders have to quote workable rate for schedule CAMC schedule.
Supply, installation, testing and commissioning of IPIS system at Kannur station in connection with the work " Improvements to Passenger Amenities including improvements to platform, development of Circulating area and Parking & Provision of IRS type Platform shelters of KANNUR Station under Amrit Bharath Station Scheme" with CAMC for 6 years.
J-SG-OT-02-2025-549902
J-SG-OT-02-2025-549902
Open
Works - General
6 Months
Palakkad, Kerala
₹0
₹2.3 L
25 Apr 2025
3 Apr 2025
206 items across 7 schedules
| # | Description | Unit | Qty | Rate | Amount |
|---|---|---|---|---|---|
| — | — | — | 1,56,40,765.61 | ||
| — | 9.00 | — | — | ||
| Supply of single line double face platform display board as per RDSO's Specification No.RDSO/SPN/ TC/ 108/ 2019, Ver-1 and latest amendments. The item supplied should be integrated with already installed CDC of ARECA make. Inspection by RDSO | — | — | — | 21,78,000 | |
| — | 9.00 | — | — | ||
| Installation , testing and commissioning of single line double face platform display boards as per RDSO's Specification No.RDSO/SPN/TC/108/2019, Ver-1 and latest amendments. Class C surge protection shall be provided by the contractor. All materials required for the installation shall be supplied by the contractor | — | — | — | 1,75,329 | |
| — | 87.00 | — | — | ||
| Supply of double faced Coach guidance display boards as per RDSO's Specification No.RDSO /SPN /TC/108/2019, Ver-1 and latest amendments. The item supplied should be integrated with already installed CDC of ARECA make. Inspection by RDSO | — | — | — | 33,01,435.11 | |
| — | 75.00 | — | — | ||
| Installation, Testing and Commissioning of Coach Guidance display board and Junction box in covered area following daisy chain topology as per the instruction of site in charge. All fixtures required for this purpose shall be arranged by the contractor at his own cost as per RDSO's Specification No.RDSO/SPN/TC/ 108/2019, Ver-1 and latest amendments. | — | — | — | 2,29,500 | |
| — | 12.00 | — | — | ||
| Installation, testing and commissioning of coach guidance display board and Junction box in open area following daisy chain topology. This includes supply, fabrication and erection of pole of 75 mm. dia. approx., angles, fastenings, rain hood, nut-bolts and other hanging arrangements as per site requirement and instruction of Railway representative at site. | — | — | — | 76,500 | |
| — | 1.00 | — | — | ||
| Supply of LED based single faced 5 line trainarrival/departure display board as per RDSO's Specification No.RDSO/SPN/ TC/108/2019, Ver-1 and latest amendments. Class C surge protection shall be provided by the contractor. The item supplied should be integrated with already installed CDC of ARECA make. Inspection by RDSO | — | — | — | 5,26,363 | |
| — | 1.00 | — | — | ||
| Installation and commissioning of single face 5 line display board.It includes supply of miscellaneous item for execution of work. The work shall be executed as per RDSO's Specification No.RDSO/SPN/TC/108/ 2019, Ver-1 and latest amendments. All materials required for the installation shall be supplied by the contractor | — | — | — | 27,321 | |
| — | 1.00 | — | — | ||
| Supply of True colour Outdoor Video Display (OVD) 6-line single face as per RDSO Specification No.RDSO/SPN/TC /108/2019, Ver-1.0 and latest Amdt. The item supplied should be integrated with existing CDC of ARECA make. Inspection by RDSO | — | — | — | 19,13,996 | |
| — | 1.00 | — | — | ||
| Installation testing and Commissioning of True colour(Outdoor Video display (OVD) (6- line single face) with required Mechanical structure and as per site condition. | — | — | — | 1,43,549.7 | |
| — | 5.00 | — | — | ||
| Supply of Platform Data Controller (PDC) as per RDSO's Specification No.RDSO/SPN/TC/108/2019, Ver-1 and latest amendments. The item supplied should be integrated with already installed CDC of ARECA make. Inspection by RDSO | — | — | — | 2,29,195 | |
| — | 4.00 | — | — | ||
| Installation and commissioning of PDC (Platform Data Controller) in19" EuroRack of suitable height ,6 port LIU (6fibre) and rack mountable power sockets. All materials required for the installation such as rack,LIU etc.. shall be supplied by the contractor. | — | — | — | 26,872 | |
| — | 7500.00 | — | — | ||
| Supply of flexible PVC insulated power cable 2.5 sq mm 3 core multi strand copper cable conform to specification no. IS: 694:1990 reaffirmed 1995 or latest. Inspection by RITES. | — | — | — | 7,12,500 | |
| — | 4000.00 | — | — | ||
| Supply of single mode 6 fibre unarmoured optic fibre cable with OEM test report. make: D link/ finolex/ polycab/paramount. Inspection by consignee. | — | — | — | 60,000 | |
| — | 3500.00 | — | — | ||
| Supply of 12 fiber unarmoured Optic Fibre cable with OEM test report. make: D link/ finolex/ polycab/paramount. Inspection by consignee. | — | — | — | 72,800 | |
| — | 7500.00 | — | — | ||
| Supply of Shielded twisted pair CAT-6 cable complied with EIA/TIA-568-B with OEM test report . Make: Dlink/ MOLEX/FINOLEX/DAX. Inspection by consignee. | — | — | — | 3,37,500 | |
| — | 2600.00 | — | — | ||
| Supply of duplex shielded cable for public address system wiring with 2 core copper cable , 32 strands, 0.2 sqmm/ strand with double jacketing and shielded. Inspection by: Consignee. | — | — | — | 2,41,800 | |
| — | 1500.00 | — | — | ||
| Supply of UTP CAT 6 cable-23 AWG Polycab/Molex/Commscope/ DAX. Inspection by consignee. | — | — | — | 42,960 | |
| — | — | — | test | ||
| — | — | — | report. | ||
| — | — | — | Make: | ||
| — | 100.00 | — | — | ||
| " Supply, Transportation &Laying/ clamping /threading of XLPE cable 16 Sq mm 4core Aluminium through trench, Cable protection pipe, Wall/shelters, FOB, etc as directed at site, with suitable clamps and termination duly supplying required cable glands,Aluminium sockets, etc." | — | — | — | 27,000 | |
| — | 500.00 | — | — | ||
| Supply and fixing of PVC trunking 100mmx 50 mm with suitable cover (Closed PVC duct) manufactured in accordance with Indian Standard IS : 14927 Part-2. Make: OBO/Legrand/ Honeywell . Inspection by: consignee. | — | — | — | 4,75,000 | |
| — | 500.00 | — | — | ||
| Supply and fixing of PVC trunking 50mmx 50 mm with suitable cover (Closed PVC duct) manufactured in accordance with Indian Standard IS : 14927 Part-2. Make: OBO/Legrand/ Honeywell. Inspection by: consignee. | — | — | — | 2,10,000 | |
| — | 600.00 | — | — | ||
| Cutting of trench across/on the platform for a depth of 10 cm with marble cutting machine and filling the trench after cable laying and restoring the surface with concrete/ plaster etc. Trenching on the platform to a depth of 1 meter in non concreted area, or to a depth of 60 cm wherever RCC slabs are available. Filling the trench after cable laying and restoring the surface to normal condition with plaster etc.. as per the site condition. | — | — | — | 1,20,000 | |
| — | 250.00 | — | — | ||
| Supply and fixing of GI pipes (50 mm dia-3.65 mm thick) for laying of cable to the PF shelter from ground level. Entry of cables will be advised by the site in charge of the Railway and extending by suitable dia HDPE/ PVC pipe on either side as required.The G I pipe should be with ISI standard. Make: TATA,Jindal, Apollo,Kalinga. Testcertificate for compliance of IS1239 (part1:2004) shall besubmitted by the contractor. Inspection: Consignee. | — | — | — | 93,750 | |
| — | 1900.00 | — | — | ||
| Supply and fixing of 14 SWG hot dipped G.I perforated cable trays of size width(300mm) X height (50mm)with suitable fixing arrangements at shelter as directed by site engineer. Inspection by RITES. | — | — | — | 20,71,000 | |
| — | 5000.00 | — | — | ||
| Supply of PVC conduit pipe of 25 mm dia , 1.8 mm thickness minimum with ISI standard. A l l fixing materials like clamps, bends , junction box etc.. Shall be supplied by the contractor. Inspection by Consignee | — | — | — | 1,70,000 | |
| — | 1500.00 | — | — | ||
| Supply of PVC caping and casing 1" size as per ISI standard. Inspection: Consignee. | — | — | — | 40,890 | |
| — | 600.00 | — | — | ||
| Supply and fixing of casing & capping 50 mm sizeas per ISI standard All required materials for fixing clamps etc. to be supplied by the contractor. | — | — | — | 56,100 | |
| — | 6500.00 | — | — | ||
| Fixing of PVC pipe/casing and caping etc. All fixing materials required for the work shall be supplied by the contractor. | — | — | — | 1,45,470 | |
| — | 14500.00 | — | — | ||
| Drawal/laying of STP/OFC/power cable/PA cable etc. through PVC conduit/HDPE pipe /GI pipe/trunking/ cable tray etc. Work shall be done as per the instruction of Railway Engineer in charge. | — | — | — | 1,55,730 | |
| — | 6.00 | — | — | ||
| Supply and installation of 55 inch full HD large format LED TV, suitable for working 24 x 7,365 days, with HDMIports with all accessories. HDMI cables shall be supplied by the contractor as per RDSO's Specification No.RDSO/SPN/TC/108/2019, Ver-1 and latest amendments. Fixing and mounting arrangements as per the site conditions shall be carried out by the contractor in consultation with the railway supervisor in-charge. Inspection by consignee. | — | — | — | 3,27,858 | |
| — | 2.00 | — | — | ||
| Supply and installation of amplifier 500 watt. Make: Ahuja /JBL / Shure/ Bose. Inspection: Consignee | — | — | — | 58,520 | |
| — | 68.00 | — | — | ||
| Supply and installation of PA column speaker with 10/15/20 Watt tapping with matching transformer and driver unit, Make : Ahuja SCM 30Tor better.Inspection by Consignee. | — | — | — | 1,75,236 | |
| — | 2.00 | — | — | ||
| Supply, installation and testing of heavy duty paging microphone (Goose Neck) with stand similar to Ahuja make or better.Inspection by Consignee | — | — | — | 5,530.1 | |
| — | 10.00 | — | — | ||
| Supply, installation and testing of wall speaker with volume controller Ahuja WS 664T or similar. Inspection by Consignee. | — | — | — | 12,197.5 | |
| — | 68.00 | — | — | ||
| Supply and provision of strip connectors / ARA terminals housed in FRP box for isolating speakers as per the instruction of SSE in charge. | — | — | — | 44,608 | |
| — | 1.00 | — | — | ||
| Supply and installation of online 10 KVA UPS with suitable battery for one hour backup on full load & battery trolley . Separate MCBs shall be provided for each platform display boards. Make: APC/ Numeric/ Delta/Luminous/Hykon. Inspection: Consignee. | — | — | — | 1,47,102 | |
| — | 75.00 | — | — | ||
| Supply of optical Patch cord of length 5 mtr as per the site condition. Inspection: Consignee. | — | — | — | 33,750 | |
| — | 10.00 | — | — | ||
| Supply and installation of 8 port POE (giga ethernet) manageable switch with two fibre ports Make. Dlink/TP link/Netgear or similar ( Gigabit SFP loaded). Consignee inspection. | — | — | — | 1,07,000 | |
| — | 1.00 | — | — | ||
| Supply of L3 manageable network switch with 24 x 1G optical port (SFP) and 4 Nos of 10GB optical port with SFP module for all ports. Make Netgear / CISCO/D Link or similar. Consignee inspection. | — | — | — | 1,63,350 | |
| — | 25.00 | — | — | ||
| Supply of electronic push button telephone with caller ID and speaker . Make: Beetel/Panasonic. Consignee inspection. | — | — | — | 22,000 | |
| — | 10.00 | — | — | ||
| — | 10.00 | — | — | ||
| — | — | — | 1,43,200 | ||
| — | 2.00 | — | — | ||
| — | — | — | 55,000 | ||
| — | 1000.00 | — | — | ||
| — | — | — | 71,600 | ||
| — | 1000.00 | — | — | ||
| — | — | — | 17,500 | ||
| — | 1000.00 | — | — | ||
| — | — | — | 16,000 | ||
| — | 1.00 | — | — | ||
| — | — | — | 33,000 | ||
| — | 4.00 | — | — | ||
| Supply and fixing of rack/wall mountable 24F fibre management system (FMS) suitable for splicing and patching for 24F cable with all accessories and terminating the optical fibre cable with splicing and patching in the FMS in the rack/wall. (Optical pigtail, patch chords of suitable length and all other materials required for splicing are to be supplied by contractor). Inspection by consignee. | — | — | — | 85,920 | |
| — | 2.00 | — | — | ||
| Supply and Installation of OBO or similar make Encapsulated class B &C SPD Power line protection forSingle phase 230V AC incoming linewith, a) OBO model: MCD 50-B320(Lightning impulse Current -limp-50KA):Line to Neutral - 1 No.b) MCD 125-B/NPE (LightningImpulse Current limp - 125KA)Neutral to Protective Earth - 1 No.c) V20 - C/1 320V ( MaximumDischarge Current - Imax - 40KA) Line to Neutral - 1 No. d) Supply ofEnclosure Box. Inspection by consignee | — | — | — | 50,398.2 | |
| — | 2.00 | — | — | ||
| Supply of optical time domain refectometer (OTDR). Fiber compatibility single mode. Central wavelength (nm) 1310& 1550, wavelength range 850 to 1650 nm dynamic range @ max wavelength 24 decibel, connectivity interface USB, RJ 45, Rechargeable battery Li-on, capacity 5200 mAh minimum. Operating time per full charge 10 hrs. Make Skycom or similar. Inspection by consignee. | — | — | — | 76,000 | |
| — | 300.00 | — | — | ||
| Supply of Flexible hose 25mm as per ISI standard. Inspection: Consignee. | — | — | — | 6,450 | |
| — | — | — | 1.12 | ||
| — | 9.00 | — | — | ||
| CAMC for single line double face platform display board | — | — | — | 0.09 | |
| — | 87.00 | — | — | ||
| CAMC for double faced Coach guidance display boards | — | — | — | 0.87 | |
| — | 1.00 | — | — | ||
| CAMC for LED based single faced 5 line trainarrival/departure display board | — | — | — | 0.01 |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
HTML
nit.pdf
NIT
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .