Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹16.7 LAccepted-AOC | 1 | Accepted-AOC Lowest,Technically and Financially qualified | |
| 2 | 2₹16.8 L+₹13,900.16 (0.83%)Rejected-AOC | 2 | Rejected-AOC 2nd lowest | |
| 3 | 3₹16.9 L+₹17,442.72 (1.04%)Rejected-Finance | 3 | Rejected-Finance Highest |
Tender Value
Refer Docs
EMD Value
₹43,000
Closing Date
24 Nov 2020, 11:00 amClosed
The Deputy Chief Engineer Transmission Circle Pvth
O/o the Deputy Chief Engineer , Transmission Circle, Poovanthuruthu,
Renovation and Upgradation of Protection System in 220kV and above Sub station in Kerala- Extension of Mux Room at Communication Room Pallom
2020_KSEB_399230_1
TCP/DBC1/Re e tender 05/2020-21 dtd 11.11.2020
Open Tender
Civil Works - Buildings
Item Rate
270 days
Poovanthuruthu
Please refer Tender documents.
8 documents required · 8 mandatory
₹5,900
₹43,000
16 Jan 2021
16 Nov 2020
26 Nov 2020
16 Nov 2020
24 Nov 2020
16 Nov 2020
16 Nov 2020 - 24 Nov 2020
Part A -Civil Part
Taking out doors,windows and clerestory window shutters(steel /Aluminium or wood)of area 3 sq metres and below including stacking etc. complete as per the direction of the departmental officers
Demolishing brick work in cement mortar manually/by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-Charge.
Demolishing Reinforced cement concrete manually/by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-Charge.
Repairs to plaster of thickness 12 mm to 20 mm in patches of area 2.5 sq meters and under, including cutting the patch in proper shape, raking out joints and preparing and plastering the surface of the walls complete, including disposal of rubbish to the dumping ground within 50 metres lead: With cement mortar 1:4 (1 cement : 4 fine sand) etc complete as per the direction of the departmental officers
Dismantling cement asbestos or other hard board or PVC ceiling, or partition walls including stacking of serviceable materials and disposal of unserviceable materials within 50 metres lead
Clearing grass and removal of rubbish up to a distance of 50m outside the periphery of the area cleared.
Earth work in excavation by mechanical means (Hydraulic excavator) / manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including disposal of excavated earth, lead up to 50 m and lift up to 1.5 m, disposed earth to be levelled and neatly dressed. All kinds of soil
Extra for additional lift of 1.50m or part there of in excavation /banking excavated or stacked materials in all class of soil
Providing and laying in position Cement, Concrete of specified grade excluding the cost of centering and shuttering - All works up to plinth level: 1:4:8 (1 Cement: 4 coarse sand: 8 graded aggregate 40mm nominal size) compacting, curing etc. complete
Random rubble masonry with hard stone in foundation and plinth including levelling up with cement concrete 1:6:12 (1 cement : 6 coarse sand : 12 graded stone aggregate 20 mm nominal size) upto plinth level with cement mortar1:6.
Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundation etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming, watering & leveling etc, complete as per the directions of departmental officers at site
Cement concrete flooring 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate) finished with a floating coat of neat cement, including cement slurry, but excluding the cost of nosing of steps etc. complete.
Centering and shuttering including strutting, propping etc. and removal of form for walls of (any thickness )including attached pilasters, butteresses, plinth string curses and cable trench etc
Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level for bottom and side walls of cable trench . 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size)(cement content 320kg/m3).
Solid block masonry using pre cast concrete solid blocks (factory made) of size 40x20x15cm or nearest available size confirming to IS 2185 part 1 of 1979 for super structure upto floor two level and above in: CM 1:6 (1 cement : 6 coarse sand) etc complete
Centering and shuttering including strutting, propping etc. and removal of form for Lintels,Sun shade , beams, plinth beams, girders, bressumers and cantilevers
Centering and shuttering including strutting, propping etc. and removal of form for Suspended floors, roofs, landings, balconies and access platform etc. for mass concrete.
RCC 1:1.5:3, in beams, suspended floors, roofs having slope upto 15 degree landings, balconies, shelfs such as lintels, Sun shade , Roof slab ,banks, plain window sills, stair cases etc. using 20mm hard granite broken stone for walls upto floor V level including all cost of shoring work if any, watering, curing etc. complete but excluding the cost of formwork & reinforcement.1:1.5:3 (1 cement : 1.5 coarse sand : 3 graded stone aggregate 20 mm nominal size) (cement content 400.00kg/m3)
Providing and applying fibre reinforced elastomeric liquid water proofing membrane with resilient acrylic polymers having Sun Reflectivity Index (SRI) of 105 on top of concrete roof in three coats @10.76 litre/ 10 sqm. One coat of self-priming of elastomeric waterproofing liquid (dilution with water in the ratio of 3:1) and two coats of undiluted elastomeric waterproofing liquid (dry film thickness of complete application/system not less than 500 microns). The operation shall be carried out after scrapping and properly cleaning the surface to remove loose particles with wire brushes, complete in all respect wherever necessary as per the direction of Engineer-in-Charge.
Steel reinforcement for RCC work including straightening cutting bending placing in position and binding all complete TMT bars of grade Fe 500 D or more
Providing and fixing M.S. fan clamp type I or II of 16 mm dia M.S. bar, bent to shape with hooked ends in R.C.C. slabs or beams during laying, including painting the exposed portion of loop, all as per standard design complete.
Providing and fixing PVC pipes includings jointing of pipes with one step PVC solvent cement ,trenching, refilling & testing of joints complete as per direction of Engineer in Charge. 32 mm dia 10Kgf/cm2
Providing and fixing PVC pipes fittings includings fixing the pipe with clamps at 1.00m spacing. This includes jointing of pipes & fittings with one step PVC solvent cement ,& testing of joints complete as per direction of Engineer in Charge. 32 mm dia 10Kgf/cm2-External work-Exposed on wall
Providing and fixing PVC pipes fittings includings fixing the pipe with clamps at 1.00m spacing. This includes jointing of pipes & fittings with one step PVC solvent cement ,& testing of joints complete as per direction of Engineer in Charge. 32 mm dia 10Kgf/cm2-Concealed work including cutting chases and marking good the wall etc
Providing and fixing PVC moulded fittings / accessories for Rigid PVC pipes, including jointing with PVC solvent cement - Door Tee
Providing and fixing PVC moulded fittings / accessories for Rigid PVC pipes, including jointing with PVC solvent cement -Reducer of suitable size as per the requirment
Providing and fixing PVC moulded fittings / accessories for Rigid PVC pipes, includingjointing with PVC solvent cement - 63 mm dia Vent cowl
Providing and fixing PVC moulded fittings / accessories for Rigid PVC pipes, includingjointing with PVC solvent cement - 63 mm dia Vent pipe
Providing and fixing PVC moulded fittings / accessories for Rigid PVC pipes, including jointing with PVC solvent cement - 63 mm dia End cap
Providing and fixing PVC moulded fittings / accessories for Rigid PVC pipes, including jointing with PVC solvent cement - Bend of suitable size as per the requirment
Plastering with cement mortar 1:4, 12mm thick one coat to inside and out side walls including curing etc complete 1:4 (1 cement : 4 fine sand)
Plastering with 6 mm cement plaster of mix : 1:3 (1 cement : 3 fine sand) for under side of slab.
15mm thick cement plaster on roof top finished with a floating coat of neat cement of mix 1:3 including curing etc complete (1 cement : 3 fine sand)
Pointing on stone work with cement mortar 1:3 (1 cement : 3 fine sand) : Flush / Ruled pointing
Providing and fixing aluminium work ( for fixed portion)for doors, windows, ventilators and false ceiling with extruded built up standard tubular sections/ appropriate Z sections and other sections of approvedmake conforming to IS : 733 and IS: 1285, fixing with dash fasteners of required dia and size, includingnecessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprenegasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanicallywherever required including cleat angle, Aluminnium snap beading for glazing /paneling, C.P. brass/stainless steel screws, all complete as per architectural drawings and the directions of Engineer-incharge.(Glazing, paneling and dash fasteners to be paid for separately): For powder coatedAluminium ( minimum thickness of powder coating 50 microne)Details of cost for 24.75 kg material (1)External member of the frame (Door) size 4 to 6 cm x 2 to 3.5 cm V=2x2.35=4.70m,H=2x1.12=2.24 m=6.94m@ 1.7 kg/m=11.798kg (2) External member of the frame (Window) size 6 to 10 cm x 2.5 to 4.5 cm V=2x1.50= 3.0 m,H (Top)=2x1.41=2.82 m= 5.82m@ 1.98 kg/m=11.524kg,H (Bottom)=1x1.5= 1.50 m@ 2.64 kg/m=3.96kg (3) Angle cleat35x35x1.1mm (Jindal section No 16428, 50mm long 20x0.05=1m @ 0.205kG/m=0.205kg Sub total= 27.487kg Add 5 % wastage =1.37kg =28.86kg
Providing and fixing aluminium work for shutters of doors, windows, ventilators and partitionswith extruded built up standard tubular sections/ appropriate Z sections and other sections of approvedmake conforming to IS : 733 and IS: 1285, fixing with dash fasteners of required dia and size, includingnecessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprenegasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanicallywherever required including cleat angle, Aluminnium snap beading for glazing /paneling, C.P. brass/stainless steel screws, all complete as per architectural drawings and the directions of Engineer-incharge.(Glazing, paneling and dash fasteners to be paid for separately):for shutters of doors , windows &ventilators including providing and fixing hinges/pivots and making provision for fixing of fittings whereverrequired including the cost of EPDM rubber /Neoprene gasket required ( fittings shall be paid for saperatley powder coated Al (minimum thickness of powder coating 50 micronDetails of cost for 20.23 kg material Doors (1) External member of the frame 10.5 X 4.5 or nearest available size ,H (T & B) = 2x2x 0.96= 3.84 m @ 2.06 Kg/m=7.91Kg (2) 10.0 X 4.5 or nearest available size H (Divider)-1x2x 0.96 = 1.92m @ 1.69 Kg/m=3.245 Kg (3) 8 X 4.5 or nearest available size V= 2x 2.31=4.62 m @ 1.56Kg/m =7.207 Kg (4) Al Snap beadings on both sides 2.5 cm width @ 0.13 Kg/m 2x2x2(0.96+0.95)=14.96 m @0.13 Kg/m=1.945 Kg (4) Angle cleat 4 x 4cm 5.5cm long 20x 0.05= 1m @ 0.205 Kg/m = 0.205 Kg Windows (1) Horizontal Top & Bottom 6.5 x 2.5 cm or nearest available size 2x4.41=2.82 m @ 1.16 Kg/m=3.272 Kg ,(2) V [email protected] Kg /m = 2.58 Kg, (3)V (intermediate)-2x1.50=3m @ 1.11Kg/m= 3.33 Kg (4)Snap beading 2*3*2(1.28+0.42) =20.4 [email protected] Kg /m=2.652 Kg Sub Total= 32.346 Kg Add 5 % wastage=1.617 Kg Total =33.963 Kg
Providing and fixing glazing in aluminium door, window, ventilator shuttersand partitions etc. with EPDM rubber / neoprene gasket etc. complete as perthe architectural drawings and the directions of engineer-in-charge . (Cost ofaluminium snap beading shall be paid in basic item):
Providing and fixing 12 mm thick prelaminated particle board flat pressed three layer or graded wood particle board conforming to IS: 12823 Grade l Type ll, in panelling fixed in aluminum doors, windows shutters and partition frames with C.P. brass / stainless steel screws etc. complete as per architectural drawings and directions of engineer-in-charge. :Pre-laminated particle board with decorative lamination on both sides
Providing and fixing 100mm brass locks including triplicate keys (best make of approved quality) for aluminium doors including necessary cutting and making good etc. complete
Providing and fixing aluminium round shape handle of outer dia 100 mm with SS screws etc. complete as per direction of Engineer-in-charge ( Powder coated minimum thickness 50 micron aluminium )
Providing and fixing ISI marked oxidised M.S. tower bolt black finish, (Barrel type-Size-200x 10mm ) with necessary screws etc. complete-
Providing and fixing double action hydraulic floor spring of approved brand and manufacture conforming to IS : 6315, having brand logo embossed on the body / plate with double spring mechanism and door weight upto 125 kg, for doors, including cost of cutting floors, embedding in floors as required and making good the same matching to the existing floor finishing and cover plates with brass pivot and single piece M.S. sheet outer box with slide plate etc. complete as per the direction of Engineer-in-charge. :With stainless steel cover plate minimum 1.25 mm thickness
Filling the gap in between aluminium frame & adjacent RCC/ Brick/ Stone work /tile by providing weather silicon sealant over backer rod of approved quality as per architectural drawings and direction of Engineer-in-charge complete. Upto 5mm depth and 5 mm width
Providing and laying Ceramic glazed/non slippery floor tiles of size 300x300 mm (thickness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in all colours, shades, White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick bed of cement mortar 1:4 (1 Cement : 4 Coarse sand), including pointing the joints with white cement and matching pigments etc., complete.
Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in all colours, shades, White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick bed of cement mortar 1:4 (1 Cement : 4 Coarse sand), including pointing the joints with white cement and matching pigments etc., complete.
Providing and laying first quality ceramic wall tiles including skirting in different sizes conforming to IS : 15622 (thickness to be specified by the manufacturer) of approved make, in all colours and shades except burgundy, bottle green, black of any size approved by Engineer in Charge in skirting , risers of steps, ramps and dados over 12 mm thick cement mortar 1:3 (1 cement : 3 coarse sand),and jointing with grey cement colour @ 3.3 Kg per Sqm including pointing joints with white cement mixed with pigments of matching shade etc., complete
Providing and fixing 10 mm thick acid and / or alkali resistant tiles of approved make and colour using acid and / or alkali resisting mortar bedding, and joints filled with acid and / or alkali resisting cement as per IS : 4457, complete as per the direction of Engineer-in-Charge. - In flooring on a bed of 10 mm thick mortar 1:4 (1 acid proof cement : 4 coarse sand) - Acid and alkali resistant tile
Providing and fixing 10 mm thick acid and / or alkali resistant tiles in dado/skirting/wall on 12 mm thick mortar 1:4 (1 acid proof cement :4 Course sand) of approved make and colour using acid and / or alkali resisting mortar bedding, and joints filled with acid and / or alkali resisting cement as per IS : 4457, complete as per the direction of Engineer-in-Charge. - Acid and alkali resistant tile
Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface with water thinnable primer
Wall painting with acrylic emulsion paint of approved brand and manufacture to give an even shade two or more coats on new work .
Wall painting with acrylic emulsion paint of approved brand and manufacture to give an even shade two or more coats on old work .
Painting steel work with Deluxe Multi Surface Paint to give an even shade two or more coat applied @ 0.90 lit/10 Sqm over an under coat of primer applied @ 0.80 lit/10 Sqm of approved brand and manufacture to give an even shade after rubbing with and paper and cleaning the surfaces
Providing and fixing PTMT Soap Dish Holder having length of 138 mm, breadth 102 mm, height of 75 mm with concealed fitting arrangements, weighing not less than 106 gms.
Providing and fixing PTMT bib cock 15 mm nominal bore ,122 mm long of approved quality and colour .
Constructing soak pit 1.20x1.20x1.20 m filled with brickbats including S.W.drain pipe 100 mm diameter and 1.20 m long complete as per standard design
Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointingwithseal ring conforming toIS: 5382, leaving10mm gap for thermal expansion, (i) Single socketed pipes. 110 mm diameter
Providing and fixing white vitreous china pedestal type water closet (European type W.C. pan) with seat and lid, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever), conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required : W.C. pan with ISI marked white solid plastic seat and lid
Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including paintingo fittings and brackets,cutting and making good the walls wherever required: White Vitreous China Flat back wash basin size 550x400 mm with single 15 mm C.P. brass pillar tap
Providing and fixing mirror of superior glass (of approved quality) and of required shape and size with plastic moulded frame of approved make and shade with 6 mm thick hard board backing: Rectangular shape 453x357 mm
Providing and fixing false ceiling with 7.5mm thick PVC wooden grains panel board ceiling of approved quality in aluminium frame work with necessary screws etc complete (aluminium frame work shall be paid separately).
Providing and fixing Fiber Glass Reinforced plastic (FRP) Door Frames of cross- section 90 mm x 45 mm having single rebate of 32 mm x 15 mm to receive shutter of 30 mm thickness. The laminate shall be moulded with fire resistant grade unsaturated polyester resin and chopped mat. Door frame laminate shall be 2 mm thick and shall be filled with suitable wooden block in all the three legs. The frame shall be covered with fiber glass from all sides. M.S. stay shall be provided at the bottom to steady the frame.
Providing and fixing to existing door frames. 30 mm thick Glass Fibre Reinforced Plastic (FRP) panelled door shutter of required colour and approved brand and manufacture, made with fire - retardant grade unsaturated polyester resin, moulded to 3 mm thick FRP laminate for forming hollow rails and styles, with wooden frame and suitable blocks of seasoned wood inside at required places for fixing of fittings, cast monolithically with 5 mm thick FRP laminate for panels conforming to IS: 14856, including fixing to frames.
Transporting R.C.C Cover Slab of Different Sizes from stocked locations to the required locations as speciified(Up to 150mtr) and placing over the power/control trenches safely and carefully and leveling after cleaning the sides of slabs and cable trenches including removing and lifting to stockyard of already covered slabs for the purpose of cable laying if necessary etc as per the direction of departmental officers,Charges include all tools and hire charges and as per the direction of departmental officers at site
Part -B Electrical works
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required.
Wiring for twin control light point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, 2 way modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required.
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required,. (2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire)
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required,. (2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire)
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 A modular socket outlet and 5/6 A modular switch, connections etc. as required.
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required,. (2 X 4 sq. mm + 1 X 4 sq. mm earth wire)
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required,. (2 X 6 sq. mm + 1 X 6 sq. mm earth wire)
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 A & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required.
Supplying and fixing 3 pin, 5 A ceiling rose on the existing junction box/ wooden block including connections etc. as required.
Supplying and fixing brass batten/ angle holder including connections etc. as required.
Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required.
Supplying Ceiling fan, complete with 300mm down rod, canopies, shackles and blades and without regulator working on 230/240V single phase A/C (1200 mm sweep – 5 star rated)
Installation, testing and commissioning of pre-wired, fluorescent fitting / compact fluorescent fitting of all types, complete with all accessories and tube/lamp etc. directly on ceiling/ wall, including connections with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable and earthing etc. as required.
Providing and fixing extra conduit down rod of 20 mm dia, 2 X10 cm length, wiring with 2 X 1.5 sq. mm FRLS PVC insulated copper conductor, single core cable including painting etc. as required. (Note: More than 5 cm length shall be rounded to the nearest 10 cm and 5 cm or less shall be ignored)
Installation, testing and commissioning of ceiling fan/wall mounting fan, including wiring the down rods of standard length (upto 30 cm) with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable etc. as required.
Supplying Light Duty Exhaust fan in metal frame working on 230 V A/C, Group B (300 / 305 mm sweep)
Installation of exhaust fan in the existing opening, including making good the damage, connection, testing, commissioning etc. as required. (Upto 450 mm sweep)
Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 kV grade of following size on wall surface as required. Upto 35 sq. mm (clamped with 1mm thick saddle)
Supplying and fixing of following ways surface/ recess mounting,vertical type, 415 V, TPN MCB distribution board of sheet steel,dust protected, duly powder painted, inclusive of 200 A, tinnedcopper bus bar, common neutral link, earth bar, din bar formounting MCBs (but without MCBs and incomer) as required.(Note : Vertical type MCB TPDB is normally used where 3 phaseoutlets are required.) 8 way (4 + 24), Double door
Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar,din bar, interconnections, powder painted including earthing etc.as required. (But without MCB/RCCB/Isolator). 8 way, Double door
Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, “C” curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. (Single pole}
Supplying and fixing following rating, double pole, 240 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required. (40 A)
Supplying and fixing following rating, four pole, 415 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required. (63 A)
Supplying and fixing following rating, four pole, (three phase and neutral), 415 V, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DBcomplete with connections, testing and commissioning etc. as required. (63 A)
Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar,din bar, interconnections, powder painted including earthing etc.as required. (But without MCB/RCCB/Isolator). (16 way, Double door) (for DC supply)
Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 kV grade of following size on cable tray as required. Upto 35 sq. mm (clamped with 1mm thick saddle). For DC Supply
Earthing with G.I. earth pipe 4.5 meter long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required.
stage.html
html • 0.04 MB
tech_eval.pdf
fin_eval.pdf
aoc.pdf
finance_568002.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .