Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹32.4 LAccepted-AOC MANGERIYA MANGERIYA BHOPALGARGH JODHPUR 342901 | JODHPUR | JODHPUR | RAJASTHAN | 342901 | L1 | Accepted-AOC Accepting being L1 | |
| 2 | L2₹34.2 L+₹34,304 (1.01%)Rejected-Finance | L2 | Rejected-Finance NOT LOWEST | |
| 3 | L3₹34.5 L+₹70,764 (2.09%)Rejected-Finance | L3 | Rejected-Finance NOT LOWEST | |
| 4 | L4₹36.8 L+₹3.0 L (8.91%)Rejected-Finance | L4 | Rejected-Finance NOT LOWEST | |
| 5 | L5₹37.0 L+₹3.2 L (9.58%)Rejected-Finance PAHARGANJ SECOND COLONY LAL SAGAR JODHPUR 342001 RAJ | JODHPUR | JODHPUR | RAJASTHAN | 342001 | L5 | Rejected-Finance NOT LOWEST |
Tender Value
Refer Docs
EMD Value
₹88,000
Closing Date
25 Jul 2023, 6:00 pmClosed
GE ARMY NO 1 JODHPUR
GE ARMY NO. 1 MULTAN LINES ARMY AREA JODHPUR
REPAIR MAINT AND IMPROVEMENT OF LT DISTRIBUTION NETWORK LT PANEL FP BOX AND OTHER ALLIED WORKS IN SECTOR C SECTOR D OTM MD ACCN AREA IN ARMY AREA UNDER GE ARMY NO 1 JODHPUR
2023_MES_605885_1
GE/J/A- OF 2023-24(9176/E8)
Open Tender
Electrical and Maintenance Works
Item Rate
330 days
JODHPUR
Please refer Tender documents.
7 documents required · 7 mandatory
₹500
GE ARMY NO 1
₹88,000
Yes
17 Oct 2023
27 Jun 2023
1 Aug 2023
27 Jun 2023
25 Jul 2023
11 Jul 2023
Amount
Excavation in trenches not exceeding 1.5 m wide and not exceeding 1.5 mtr in depth for laying of cables, erection of poles, struts/stays, leveling of yard etc not exceeding 10 M² on plan and not exceeding 1.5 mtr in depth and getting out in any type of soil, complete all as specified and as directed.
Material and labour for tibba sand cushioning to underground cable screened and consolidation complete all as specified and as directed.
Supplying and laying un-reinforced precast concrete cable cover, class LV, Type I, flat, size 250 mm x 150mm x 40mm complete laid over the cable perpendicular to the cable for protection, complete all as specified and as directed.
Returning, filling in, including spreading, leveling watering and well ramming in layers n.exc 25 cm in soil, complete all as specified and as directed.
Removing of excavated soil not exc. 50 M from starting points, , complete all as specified and as directed.
Excavation in trenches not exceeding 1.5 m wide and exceeding 1.5 m in depth upto 3.0 m for erection of poles, struts/stays, leveling of yard etc not exceeding 10 M² on plan and getting out in any type of soil, complete all as specified and as directed.
Material and labour for Cement concrete (1:3:6) type C -2 using 40 mm graded stone aggregate for foundation of pole /struts/stay assembly etc., complete all as specified and as directed.
Material and labour Cement concrete (1:3:6) type C -2 using 20 mm graded stone aggregate for pedestal of poles/coping including necessary frame work ,fair finishing to exposed surfaces without using extra cement complete including form work, complete all as specified and as directed.
M&L in replacement for XLPE insulated, armoured heavy duty electric earthed cable with aluminium conductor, 1100 volts grade, cross-sectional area 25 sqmm 4 core, complete all as specified and as directed.
All as per item No. 9.00 here-in-above, but size 35 sqmm 3.5 core.
All as per item No. 9.00 here-in-above, but size 50 sqmm 3.5 core.
All as per item No. 9.00 here-in-above, but size 70 sqmm 3.5 core.
All as per item No. 9.00 here-in-above, but size 95 sqmm 3.5 core.
M&L in replacement of danger notice plate of 1.6mm thick mild steel sheet, vitreous enameled white, with letters, figures and conventional skull and bones in signal red color and fixed with M.S. clamps, bolts and nuts of approved size, for LT, 20x15cm size, complete all as specified and as directed.
Re-routing/relaying of existing LT cable XLPE insulated aluminum conductor armoured with glavanised steel wire complete of any size and core from any position i.e ground /wall/poles/ culverts etc complete with protection pipe, complete all as specified and as directed. Note:- (i) Old cable as obtained shall be re-used. (ii) Old serviceable protection cover, protection pipe and sand obtained under this item shall be reused if found serviceable. (iii) Earth work and any other new items shall be measured and paid separately under relevant items.
Supply and fix in replacement of GI tubing of size 80mm bore, light grade for protection of cables on poles / under road crossing complete all as specified and as directed.
All as per item No. 16.00 here-in-above, but size 50mm bore
All as per item No. 16.00 here-in-above, but size 40mm bore
M&L for Auguring/ Driling /Boring of holes under road, pavement, hard standing by trenchless technology by mannual /machine, including fixing of HDPE pipe of 100 mm bore dia, complete all as specified and as directed.
Cleaning and re-filling of fire extinguisher, 1 Kg, DCP (dry chemical powder) type including filling media/material and replacement of required accessories for ready to use complete all as specified and as directed.
All as per item No. 20.00 here-in-above, but 6 Kg.
All as per item No. 20.00 here-in-above, but 22.5 Kg, CO2 type
M & L for disconnecting and re connecting of burnt LT XLPE cable to OH conductor on pole/ equipment including removing of faulty part of cable, preparation of cable for connection, suitable AL lugs, nut bolts etc , complete all as specified and as directed. Note: The cost of earth work for taking out LT cable loop and refilling will deemed to be included in above quoted rate.
Material and labour in replacement for prestressed cement concrete poles 9 M long of size 102 mm x 172 mm at top and 102 mm x 279 mm at bottom class-10, conforming to relevant latest IS including dismantling and refixing of cross arm, security light fittings, brackets or any other existing fittings etc connecting, testing including dismantling and removal of broken pole and coping, complete all as specified and as directed. NOTE : - (i) Earthwork, PCC will be measured and paid separately under relevant item. (ii) Removal of dismantled items from site are included in rate quoted by the contractor.
Supply and errect in replacement steel tubular swaged poles type 410 SP-31 (9.0 metres long) complete with cast iron base plate and finial taper plug, bolts, nuts & screws conforming to relevant latest IS including dismantling and refixing of cross arm, security light fittings, brackets or any other existing fittings etc connecting, testing including dismantling and removal of broken pole and coping, complete all as specified and as directed. Note: - (i) Excavation and earthwork,PCC shall be measured and paid separately in relevant item here in after . (ii) Painting with two coats of black bituminous paint throughout internally and externally upto plating depth and the remaining external complete pole portion shall be painted with silver colour in two coats over a red oxide primer level deemed to be included in quoted rates.
Dismantling of insulators any type any size from existing poles, complete all as specified and as directed.
Fixing only of any type any size of dismantled insulators (serviceable insulators retrieved from above item No. 26.00), complete all as specified and as directed.
Supply and fix pin type porcelain insulator, vitreous white brown or green including one galvanised mild steel spindle two GI washer and GI Nuts 100 mm height 65 mm dia for 1100 volts grade complete all as specified.
Supply and fix shackle Type, porcelain, vitreous, white, brown or green insulator 1100 volt grade 75 mm in height and 90 mm dia including galvanised mild steel straps of size 30 x 3 mm, insulator bolt of 12 mm dia, washers and nut complete all as specified and as directed.
Supply, fixing, stringing, testing and commissioning of ACSR insulated rabbit conductor of size 6+1/3.35 mm (as phase wire) binding with insulators including binding material and connection of all service connections/existing cables complete all as specified and as directed. Note :- (i) Rate of dismantling of old conductor is deemed to be included in quoted rate.
Supply, fixing, stringing, testing and commissioning of ACSR bare conductor as neutral wire binding with insulators including binding material and connection of all service connections/existing cables complete all as specified and as directed. Note :- (i) Rate of dismantling of old conductor is deemed to be included in quoted rate.
M&L in replacement for stay assembly complete with 230x230x 6 mm thick plate and 16 mm dia stay rod all as shown in elect plate No-1 of SSR-part -1 including stay wire of size 7/4mm dia and suitable loop insulator of appropriate size all as specified and directed by Engr in charge. Note : Rate quoted is deemed to be included excavation in any type of soil, PCC for stay and dismantling of old stay assy.
M&L for Trimming and pruning of one tree complete cutting of all branches of any dia but not exceeding 75 mm up to a safe distance from the over head lines complete all as directed at site and disposal of branches/bushes to a distance and clearing the site all as directed by AGE EM-III. NOTE:- The necessary man power, tool & plant, cutting tools and JCB required for cutting/pruning of branches is deemed to incl in the rate quoted for the job.
Material and Labour for ZEBRA painting of PCC poles 9/11 m long alongwith road upto 1.5 m height from pedestal, with two coats of enamel synthetic paints in 30 cm height incl painting of pole coping with white paint all as directed by EIC.
M & L for steel tubular pole/rail pole upto 9/11 mtr long painting with two coats of enamel synthetic silver paints over a one coat of red oxide incl painting of pole coping with white paint and zebra painting upto 1.5 mtr from pole coping all as directed by Engr-in-Charge.
Material and labour for writing pole number of minimum 10 cm height with black paint over base of yellow paint on PCC/steel poles of LT supply complete all as directed by EIC.
Supply and fix in replacement of MCCB 4 Pole, 415 V, with Microprocessor release 400 Amps with breaking capacity 36 KA including spreader terminals, lugs,nut, bolt & washers etc complete all as specified and as directed.
All as per item No. 37.00 here-in-above, but 250 Amps, 36 kA.
Supply and fix in replacement of MCCB 4 Pole, 415 V, Adjustable type, 200 Amps with breaking capacity 36 KA including spreader terminals, lugs,nut, bolt & washers etc complete all as specified and as directed.
All as per item No. 39.00 here-in-above, but 160 Amps, 25 kA
All as per item No. 39.00 here-in-above, but 100 Amps, 16 kA
Material and labour for replacement of old unserviceable voltmeter/ Ammeter with Panel mounted multi function three phase digital energy meter of accuracy Cl-1.0 for measuring VLL, VLN, A, F, PF, A peak and making the disturbed surface good by welding/riveting in MS sheet 1.6 mm thick on the hollow portion duly painted, complete all as specified and as directed.
Material and labour for replacement of old unserviceable CT of LT Panel /Feeder pillar box with CT of ratio upto 200/5 Amps or as required at site according the load incl connecting, disconnecting and testing, complete all as specified and as directed.
Material and labour for replacement of old unserviceable indicators any type with LED based indicating lamps of RYB colour incl disconnecting and connecting of the same, complete all as specified and as directed.
Earthing complete with galvanized steel earth plate electrodes 600mmx600mmx6 mm thick buried directly in ground earth (earth pit not less 2.25 m deep below ground level) with top edge of the plate not less then 1.5 mtr below normal ground level connected to galvanised iron earthing strip 32mm x6mm thick by means of bolt nuts check nuts and washers of galvanized iron or steel all as specified & shown in electrical plate No.3 of MES SSR part-I 2009 connected to earth test point as specified and testing on completion including provision of 40 mm dia light grade pipe and earthing strip up to 7.5 mtr length as protection & watering pipe shall be 20 mm bore medium grade including all excavation & earth work in any type of strata incl PCC pit (1:3:6) type C-1 with finished stone slab cover including charcoal , salt, funnel, complete all as specified and as directed. Note : Rate included for dismantling of old earth pit and removal from site.
Material and labour for spray painting to outdoor type double door LT panels/feeder pillar box and replacement of door hinges, sliding bolts, cable entry MS sheets, cable glands, pedestal locks, bow handle and connected accessories where required by welding, cutting, drilling etc and incl fixing with MS nuts and bolts including two coats of spray painting by synthetic enameled paint, complete all as specified and as directed. Note:- Panel should be vermin proof and close properly after repair.
M&L in replacement of LT end termination, heat shrinkable, out door type, suitable for XLPE Cable of size 95 to 150 sqmm 3.5 core, 1100 volts grade complete including disconnection and connection of LT cable to OH line complete all as specified and as directed.
All as per item No. 47.00 here-in-above, but 185 to 400 sqmm 3.5 core
All as per item No. 47.00 here-in-above, but 95 to 150 sqmm 3.5 core, indoor type
All as per item No. 47.00 here-in-above, but 185 to 400 sqmm 3.5 core, indoor type
All as per item No. 47.00 here-in-above, but 35 to 70 sqmm, 3.5 core, straight through
All as per item No. 47.00 here-in-above, but 95 to 240 sqmm, 3.5 core, straight through
Supply and laying or fixing or passing through pipe, 1100 volts grade PVC insulated copper conductor served with Unsheated unarmoured and overall round cable, multistrand 16 sq. mm nominal cross section including copper lugs of suitable size, nuts, bolts and washers complete all as specified and as directed.
Supply, fixing, testing and commissioning as in replacement of LT Panel board, outdoor type, floor mounted, factory made CPRI approved suitable for 415 volt, 3 PH, 4 wire, 50 Hz, AC supply system having bus bar chamber with copper bus bars duly insulated by insulation of RYB colure 400 Amps rating mounted on porcelain insulators. The panel shall be powder coated, factory made double door made out of 3.15 mm thick MS sheet (size of Panel shall be not less then 1.20 m x 0.90 x0.40 m) totally enclosed dust, vermin and rust proof front operated, front and rear opening with locking arrangement fixed with MS angle iron frame of size 40mm x40mm x6mm duly embedded in PCC (1:3:6) type C-1 platform and including wiring of multistranded copper cable of suitable size including lugs and cable gland to incoming and outgoing cables and re-routing of LT cables of change over within 10 mtr of distance etc all as directed at site and comprising of following:-
INCOMING:-
(a) MCCB 4 Pole 415 volts 36 KA 200 Amps rating TM adjustable type (Icu=Ics=100%) - 01 Nos
(b) Panel mounted digital voltmeter of accuracy Cl-1.0 rating - 01 No
(c) Panel mounted digital ammeter of accuracy Cl-1.0 rating - 01 No
(d) RYB LED indication lamp panel mounting type (Set of three) - 01 No
OUTGOING
(a) MCCB 4 Pole 415 volts 25 KA 160 Amps rating TM adjustable type - 01 Nos
(b) MCCB 4 Pole 415 volts 25 KA 100 Amps rating TM adjustable type - 02Nos
(c) MCB TPN 415 volts 10 KA 63 Amps - 01 Nos
Supply, fixing, testing and commissioning as in replacement of LT Panel board, outdoor type, floor mounted, factory made CPRI approved suitable for 415 volt, 3 PH, 4 wire, 50 Hz, AC supply system having bus bar chamber with copper bus bars duly insulated by insulation of RYB colure 800 Amps rating mounted on porcelain insulators. The panel shall be powder coated, factory made double door made out of 3.15 mm thick MS sheet (size of Panel not less then 1.20 m x 1.20 x 0.50 m) totally enclosed dust, vermin and rust proof front operated, front and rear opening with locking arrangement fixed with MS angle iron frame of size 40mm x40mm x6mm duly embedded in PCC (1:3:6) type C-1 platform and including wiring of multistranded copper cable of suitable size including lugs and cable gland to incoming and outgoing cables and re-routing of LT cables of change over within 10 mtr of distance etc all as directed at site and comprising of following:-
INCOMING:-
(a) MCCB 4 Pole 415 volts 36 KA 400 Amps rating microprocessor release type (Icu=Ics=100%) - 01 Nos
(b) Panel mounted digital voltmeter of accuracy Cl-1.0 rating - 01 No
(c) Panel mounted digital ammeter of accuracy Cl-1.0 rating - 01 No
(d) RYB LED indication lamp panel mounting type (Set of three) - 01 No
OUTGOING
(a) MCCB 4 Pole 415 volts 36 KA 250 Amps rating MT adjustable type - 02 Nos
(b) MCCB 4 Pole 415 volts 25 KA 160 Amps rating microprocessor release type - 02 Nos
(c) MCB TPN 415 volts 10 KA 63 Amps - 02 Nos
Supply, fixing, testing and commissioning as in replacement of LT Panel board, outdoor type, floor mounted, factory made CPRI approved suitable for 415 volt, 3 PH, 4 wire, 50 Hz, AC supply system having bus bar chamber with copper bus bars duly insulated by insulation of RYB colure 400 Amps rating mounted on porcelain insulators. The panel shall be powder coated, factory made double door made out of 3.15 mm thick MS sheet (size of Panel not less then 1.20 m x 1.20 x 0.4 m) totally enclosed dust, vermin and rust proof front operated, front and rear opening with locking arrangement fixed with MS angle iron frame of size 40mm x40mm x6mm duly embedded in PCC (1:3:6) type C-1 platform and including wiring of multistranded copper cable of suitable size including lugs and cable gland to incoming and outgoing cables and re-routing of LT cables of change over within 10 mtr of distance etc all as directed at site and comprising of following:-
INCOMING:-
(a) MCCB 4 Pole 415 volts 36 KA 250 Amps rating TM adjustable type (Icu=Ics=100%) - 01 Nos
(b) Panel mounted digital voltmeter of accuracy Cl-1.0 rating - 01 No
(c) Panel mounted digital ammeter of accuracy Cl-1.0 rating - 01 No
(d) RYB LED indication lamp panel mounting type (Set of three) - 01 No
OUTGOING
(a) MCCB 4 Pole 415 volts 25 KA 160 Amps rating TM adjustable type - 03 Nos
(a) MCCB 4 Pole 415 volts 25 KA 100 Amps rating TM adjustable type - 02 Nos
(b) MCB TPN 415 volts 10 KA 63 Amps - 01 Nos
M&L in replacement cross arms, bracings, supports, clamps,ladder and back plates fabricated from steel sections including nuts, bolts, washer, welding, bending cold or hot, drilling holes for bolts, in any shape or size as indicated or directed and inclusive of two coats of aluminum paint over one coat of red oxide primer over & including M&L primer and incld dismantling of unservicable steel structure, cross arms, bracings, supports, clamps from two /four pole stucture complete all as specified and as directed .
M&L Installation Board of size 5 mtr X 2.5 mtr made of 1.6 mm galvanised sheet duly painted both side including frame work and detail nominclature of the installation as directed by EIC and mounted on the existing mounting structure,complete all as per specified and as directed.
M/s R K Enterprises
Rajesh Enterprises
S.G.ENGINEERING COMPANY
Shree Karni Construction
Nvimal Engineers and Contractor
M/S SUMAN ENTERPRISES
RISING ELECTRICALS
Shri Electrical Enterprises
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .