Loading…
Loading…
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance | Admitted-Finance |
| 2 | Admitted-Finance SHOP NO G 5 NATRAJ PALACE NEAR GAJANAN MAHARAJ MANDIR KALYAN AMBERNATH ROAD SHANTINAGAR ULHASNAGAR 3 ULHASNAGAR MAHARASHTRA 421003 | THANE | MAHARASHTRA | 421003 | Admitted-Finance |
Tender Value
Refer Docs
Closing Date
22 Dec 2021, 11:00 amClosed
CM MES
CM MES CONTRACT CELL RCF LTD. TROMBAY
INSTALLATION, COMMISSIONING and TESTING OF ONE POWER DISTRIBUTION PANEL AT TRAINING CENTRE WORKSHOP AND INSTALLATION OF ONE POWER DB IN R and D CHEMICAL PILOT PLANT AT RCFL TROMBAY
2021_RCFL_659243_2
ET-CC/POWER DB REPLACEMENT/EWS/2122-53
Open Tender
Miscellaneous Services
Works
730 days
RCFLtd. Chembur
As per Tender
10 documents required · 10 mandatory
₹0
Exempted
11 Feb 2022
15 Dec 2021
22 Dec 2021
15 Dec 2021
22 Dec 2021
15 Dec 2021
Amount
a) Removal of old power distribution system, and send to scrap yard after weighing. b) Shifting of 1 Nos. New Power Distribution Panel from Electrical Store to Locations c) Installation, Testing and commissioning of 1 No. new Power Distribution Panels at Training Centre Workshop
Complete fabrication work such as M.S. frame for Panel, cable rack, supports etc
Disconnection and Removal of Cables from old Power Distribution system
Cable laying, above 4CX 1.5 Sqmm upto 4C X 16 Sq.mm Al. Cable, if required
Cable laying, above 4CX 16 Sqmm upto 4C X 50 Sq.mm Al. Cable, if required
Cable laying, above 4CX 50 Sqmm upto 4C X 120 Sq.mm Al. Cable, if required
Cable laying, above 4CX 120 Sqmm upto 4C X 300 Sq.mm Al. Cable, if required
Cable Termination, above 4CX 1.5 Sqmm upto 4C X 16 Sq.mm Al. Cable
Cable Termination, above 4CX 16 Sqmm upto 4C X 50 Sq.mm Al. Cable
Cable Termination, above 4CX 50 Sqmm upto 4C X 120 Sq.mm Al. Cable
Cable Termination, above 4CX 120 Sqmm upto 4C X 300 Sq.mm Al. Cable
Supply and making of M-seal straight joint, 1.1 KV LT above 4CX 1.5 Sqmm upto 4C X 16 Sq.mm Al. Cable if required
Supply and making of M-seal straight joint, 1.1 KV LT above 4CX 16 Sqmm upto 4C X 50 Sq.mm Al. Cable if required
Supply and making of M-seal straight joint, 1.1 KV LT above 4CX 50 Sqmm upto 4C X 120 Sq.mm Al. Cable if required
Supply and making of M-seal straight joint, 1.1 KV LT above 4CX 120 Sqmm upto 4C X 300 Sq.mm Al. Cable if required
Laying and fixing of GI strip/Al cable Single core upto 25 sq.mm on wall/structure/cable trays including supply of clamps, hardware and with connections at main earth strips, intermediate joints and equipments
Installation of GI/AI/Earth strip conductor size upto 50 mm x 6 mm above ground on racks/wall surface/ structure as required including supply of GI hardware and making bolted/welded/brazed connections between individual strips, earth electrodes and equipment
Installation, Testing and commissioning of 1 No. new Power Distribution Panels at R & D Chemical Pilot project
Complete fabrication work such as M.S. frame for Panel, cable rack, supports etc.
Cable laying, above 4CX 1.5 Sqmm upto 4C X 16 Sq.mm Al. Cable, if required
Cable laying, above 4CX 16 Sqmm upto 4C X 50 Sq.mm Al. Cable, if required
Cable laying, above 4CX 50 Sqmm upto 4C X 120 Sq.mm Al. Cable, if required
Cable laying, above 4CX 120 Sqmm upto 4C X 300 Sq.mm Al. Cable, if required
Underground Cable laying, above 4CX 50 Sqmm upto 4C X 120 Sq.mm Al. Cable, if required
Cable Termination, above 4CX 1.5 Sqmm upto 4C X 16 Sq.mm Al. Cable
Cable Termination, above 4CX 16 Sqmm upto 4C X 50 Sq.mm Al. Cable
Cable Termination, above 4CX 50 Sqmm upto 4C X 120 Sq.mm Al. Cable
Cable Termination, above 4CX 120 Sqmm upto 4C X 300 Sq.mm Al. Cable
Laying and fixing of GI strip/Al cable Single core upto 25 sq.mm on wall/structure/cable trays including supply of clamps, hardware and with connections at main earth strips, intermediate joints and equipments
Installation of GI/AI/Earth strip conductor size upto 50 mm x 6 mm above ground on racks/wall surface/ structure as required including supply of GI hardware and making bolted/welded/brazed connections between individual strips, earth electrodes and equipment
Fixing of celling fan/wall mounted fan/ exhaust fan up to size 450 mm, their connection and earthing
Installation and connection of LED light fitting up to 120 W
Installation of Lighting DB upto size 750x500x250 mm with grouting the frame in the wall & including required hardware
shree ganesh electricals
stage.html
html • 0.03 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .