| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹12.6 LAccepted-AOC 59 NEW MARKET CLOCK TOWER DEHRADUN UK PIN 248001 | DEHRADUN | UTTARAKHAND | 248001 | L1 | Accepted-AOC AOC | |
| 2 | L2₹14.2 L+₹1.6 L (12.5%)Rejected-Finance RADHA NIKUNJ L 2 SOUTH CIVIL LINES ROORKEE HARIDWAR UTTARAKHAND 247667 | ROORKEE | HARIDWAR | UTTARAKHAND | 247667 | L2 | Rejected-Finance Other than Lowest | |
| 3 | L3₹14.6 L+₹1.9 L (15.2%)Rejected-Finance TEHSIL SARKAGHAT P O RAKHOH VILL GADHANI SARKAGHAT MANDI HP 175024 | MANDI | HIMACHAL PRADESH | 175024 | L3 | Rejected-Finance Other than Lowest | |
| 4 | L4₹15.5 L+₹2.9 L (22.6%)Rejected-Finance | L4 | Rejected-Finance Other than Lowest | |
| 5 | L5₹15.8 L+₹3.1 L (24.8%)Rejected-Finance HOUSE NO 40 CHOTTI BARADARI PART I GARHA ROAD NEAR MEDICAL COLLEGE JALANDHAR PB 144022 | JALANDHAR | JALANDHAR | PUNJAB | 144022 | L5 | Rejected-Finance Other than Lowest |
Tender Value
₹20.3 L
EMD Value
₹40,583
Closing Date
21 Mar 2025, 6:00 pmClosed
CWE Hills Dehradun
HQ CWE Hills Mall Road Dehradun Cantt 248003
SPECIAL REPAIR / REPLACEMENT OF BER AIR CONDITIONERS AT NHO DEHRADUN
2025_MES_699575_1
85430/CLT/E8
Open Tender
Electrical and Maintenance Works
Item Rate
150 days
GE Clement Town
Class E cat b (i)
6 documents required · 6 mandatory
₹500
Yes
GE Clement Town
₹40,583
Yes
8 May 2025
27 Feb 2025
29 Mar 2025
27 Feb 2025
21 Mar 2025
15 Mar 2025
Amount
Supply, installation, commissioning and testing of Hi wall split type airconditioning units indoor/outdoor complete with cordless remote control unit and with in built heating and cooling arrangement and digital invertor twin roratry compressor air ioniser and plasma filter for better indoor air quality with minimum 3 star rating and EER 3.2 of capacity 1.5TR (4500 Kcal/Hr) complete of comprising of the following:- (a) Room evaporative indoor unit with three speed blower fan of appropriate capacity including PCB, thermostatic control, air filter and drain for condensing water. (b) Out door condensing unit of capacity 4500 K Cal / Hrs comprising of 01 no. compressor of 1.5TR capacity with condenser fan motor of appropriate capacity - 01 No, air cooled condenser of 1.5TR capacity - 01 No, shall be installed out side the building. (c). Refrigerant copper pipe for suction & discharge line with insulation, condensing water drain pipe & protected by suitable size of flexible PVC conduit with control valves & safety accessories including control wiring for evaporator & condensing unit with suitable size of copper cable shall be fixed. (d) Making good the disturbed surface to match the existing surface after plugging the hole etc . Note :- (i). Cutting holes in walls/window of any thickness for installation of AC etc, connection and making good the disturbed surface to match with the existing surface after work shall be done. The unit rate quoted by contractor shall deemed to be inclusive of this aspect. (ii) Electrical cable required to connect outdoor unit with indoor unit and indoor unit to voltage stabilizer inclusive in above rate. (iii) copper piping/with insulations and drain piping shall also deemed to be inclusive in quoted unit rate.
Supply, installation, commissioning and testing of Hi wall split type airconditioning units indoor/outdoor complete with cordless remote control unit and with in built heating and cooling arrangement and digital invertor twin roratry compressor air ioniser and plasma filter for better indoor air quality with minimum 3 star rating and EER 3.2 of capacity 2.00TR (4500 Kcal/Hr) complete of comprising of the following:- (a) Room evaporative indoor unit with three speed blower fan of appropriate capacity including PCB, thermostatic control, air filter and drain for condensing water. (b) Out door condensing unit of capacity 4500 K Cal / Hrs comprising of 01 no. compressor of 1.5TR capacity with condenser fan motor of appropriate capacity - 01 No, air cooled condenser of 1.5TR capacity - 01 No, shall be installed out side the building. (c). Refrigerant copper pipe for suction & discharge line with insulation, condensing water drain pipe & protected by suitable size of flexible PVC conduit with control valves & safety accessories including control wiring for evaporator & condensing unit with suitable size of copper cable shall be fixed. (d) Making good the disturbed surface to match the existing surface after plugging the hole etc . Note :- (i). Cutting holes in walls/window of any thickness for installation of AC etc, connection and making good the disturbed surface to match with the existing surface after work shall be done. The unit rate quoted by contractor shall deemed to be inclusive of this aspect. (ii) Electrical cable required to connect outdoor unit with indoor unit and indoor unit to voltage stabilizer inclusive in above rate. (iii) copper piping/with insulations and drain piping shall also deemed to be inclusive in quoted unit rate.
Supply, installation, commissioning and testing Cassette type units indoor/outdoor complete with cordless remote control unit and with in built heating and cooling arrangement and digital invertor twin roratry compressor air ioniser and plasma filter for better indoor air quality with minimum 3 star rating and EER 3.2 of capacity 1.5TR (4500 Kcal/Hr) complete of comprising of the following:- (a) Room evaporative indoor unit with three speed blower fan of appropriate capacity including PCB, thermostatic control, air filter and drain for condensing water. (b) Out door condensing unit of capacity 4500 K Cal / Hrs comprising of 01 no. compressor of 1.5TR capacity with condenser fan motor of appropriate capacity - 01 No, air cooled condenser of 1.5TR capacity - 01 No, shall be installed out side the building. (c). Refrigerant copper pipe for suction & discharge line with insulation, condensing water drain pipe & protected by suitable size of flexible PVC conduit with control valves & safety accessories including control wiring for evaporator & condensing unit with suitable size of copper cable shall be fixed. (d) Making good the disturbed surface to match the existing surface after plugging the hole etc . Note :- (i). Cutting holes in walls/window of any thickness for installation of AC etc, connection and making good the disturbed surface to match with the existing surface after work shall be done. The unit rate quoted by contractor shall deemed to be inclusive of this aspect. (ii) Electrical cable required to connect outdoor unit with indoor unit and indoor unit to voltage stabilizer inclusive in above rate. (iii) copper piping/with insulations and drain piping shall also deemed to be inclusive in quoted unit rate.
Supply, installation, commissioning and testing of window type air conditioning units with cordless remote control unit and with in built cooling arrangement and digital invertor twin roratry compressor air ioniser and plasma filter for better indoor air quality with minimum 3 star rating and EER 3.2 of capacity 1.5TR (4500 Kcal/Hr) complete all as specified and directed. Note :- (i). Cutting holes in walls/window of any thickness for installation of AC etc, connection and making good the disturbed surface to match with the existing surface after work shall be done. The unit rate quoted by contractor shall deemed to be inclusive of this aspect. (ii) Electrical cable required to connect unit to voltage stabilizer inclusive in above rate.
S&F in replacement , copper pipe with insulation of size 1/2", 1/4" for Split AC of any capacity complete all as specified and directed.
All as item No 5 above but size 3/8", 5/8".
S& F sheet metal enclosure double door type for MCBs DB SPN(Single pole and neutral) 240V AC 4 way with 200 Amps rated bus bar all as specified and directed .
S&F MCB SP 6 to 32 Amp 'B' series 10 KA repturing capacity complete all as specified and directed.
S&F MCB SPN 40 Amp 240 V AC 10 KA repturing capacity all as specified and directed.
S&F AC box 15/16 amp Single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole 240 volt MCB 20 amp complete all as directed.
S&F sub main wiring alongwith earth wire (green colour) with single core FRLSH, PVC insulated, unsheathed stranded copper conductor cable of voltage rating upto and including 1100 Volts drawn in and including concealed/Surface PVC conduit (medium grade) with standard accessories and earth wire connected with main earth dolly, of the following sizes of cable & dia of conduit complete all as specified and directed:- NOTE :- (i) Two/four run of single core FRLSH PVC cable with one/two run of earth conductor and conduit shall be measured as one unit (RM). (ii) The quoted rates shall be deemed to be inclusive for cutting chases in wall/pillars/columns etc of any description for concealing the conduits to required depth & making good the disturbed surface in CM (1:3) including finishing the surface to match with the existing surface. The portion of sub main wiring at ceiling shall be in surface conduit of suitable size fixed on ceiling surface with using PVC rawal plugs.
2x4 Sqmm + 1x4 Sqmm earth wire with PVC conduit 20mm dia or more
EX SOLDIERS MECHANICAL WORKS (BID ID -3266808)
VATANUCOOL ENGINEERS (BID ID -3267812)
SHYAM AND SONS ENTERPRISES (BID ID -3266119)
UNITED ENGINEERING CORPORATION (BID ID -3268062)
Bedi Refrigeration Works (BID ID -3263974)
AIRCOM (BID ID -3266627)
Bhanu Prakash (BID ID -3267242)
Standard enterprises (BID ID -3266534)
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .