Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹17.1 LAccepted-AOC | ₹17.1 L Quoted ₹17.9 L | L1 | Accepted-AOC Lowest |
| 2 | L2₹22.7 L+₹4.7 L (26.4%)Rejected-Finance | ₹22.7 L+₹4.7 L (26.4%) | L2 | Rejected-Finance OTHER THAN LOWEST |
| 3 | L3₹23.9 L+₹5.9 L (33.1%)Rejected-Finance | ₹23.9 L+₹5.9 L (33.1%) | L3 | Rejected-Finance OTHER THAN LOWEST |
| 4 | L4₹28.1 L+₹10.2 L (56.7%)Rejected-Finance | ₹28.1 L+₹10.2 L (56.7%) | L4 | Rejected-Finance OTHER THAN LOWEST |
Tender Value
₹29.5 L
EMD Value
₹59,000
Closing Date
2 Jun 2022, 6:00 pmClosed
GE SAMBA
GE SAMBA
REWIRING REPLACEMENT OF INTERNAL ELECTRIFICATION FITTING FIXTURE ACCESSORIES AND ALLIED WORKS AT OTM ACCN UNDER AOR OF GE SAMBA
2022_MES_521698_1
GE/SMB/T-04/2022-23
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
SAMBA
REF NIT
8 documents required · 8 mandatory
₹500
Yes
GE SAMBA
₹59,000
Yes
20 Jul 2022
5 May 2022
4 Jun 2022
5 May 2022
2 Jun 2022
20 May 2022
5 May 2022 - 7 May 2022
Amount
Taking down old unserviceable aluminium point wiring (light, fan, socket , power socket and bulk head fittings) from PVC/metallic conduit,on surface wiring, on wooden batten/casings & caping complete, including fixture and fittings such as switches, ceiling roses,pendents holder, regulators, sockets and defective main switch/DB/MCB/Metal plug etc. by unscrewing carefully from boards etc complete all as specfied and directed.
Point wiring for one light/one fan controlled by one switch with 1.5 sqmm single core PVC insulated unsheathed multistranded copper conductor (FRLS) in and including PVC concealed conduit having thickness not less than 1.8 mm with sunken box having thickness not less than 2.0 mm thickness with 3 mm bakelite laminated socket ISI marked for switches and sockets , including 1.5 sqmm single core PVC insulated unsheathed multistranded copper conductor (FRLS) as earth continuity conductor connected to comman earth dolly in and including cutting chiseling for concealed piping as required and making good disturbed surface area and white wash /colour wash to matching with the existing colour and all as specified and directed . Note: (a) Insulation test of point wiring (b) colour coding is to be maintained .(Ph-Red, N-Black, Half -Yellow, Earth- Green)
All as per srl item No 2 above but for 3 pin 5 amps on independent board complete all as specified and directed.
All as per srl item No 2 above but for 3 pin 5 amps on same board complete all as specified and directed.
Point wiring for one power point controlled by one switch with 2.5 sqmm single core PVC insulated unsheathed multistranded copper conductor (FRLS) with in and including PVC concealed conduit having thickness not less than 1.8 mm with all fittings including anodise pressed steel sunken box having thickness not less than 2mm with 3mm bakelite laminated sheet ISI marked for switches and sockets , including 2.5 sqmm single core PVC insulated unsheathed multistranded copper conductor (FRLS) as earth continuity conductor connected to comman earth dolly in and including cutting chiseling for concealed piping and making good disturbed surface area and white wash /colour wash to matching with the existing colour and all as specified and directed. Note: (a) Insulation test of point wiring (b) colour coding is to be maintained .(Ph-Red, N-Black, Half -Yellow, Earth- Green)
Modular switch, 1 module, 6A SP one way complete all as specified and directed.
Modular switch, 1 module, 16A SP one way complete all as specified and directed .
Modular socket for 6 Amps 240 volts AC 2/3 pin combined suitable for inserting 2 pin 6 Amps / 3 pin 6 Amps, 2 module, complete all as specified and directed.
Modular socket for 6/16 Amps 240 volts AC 3 pin combined suitable for inserting 3 pin 6/16 Amps, 2 module, complete all as specified and directed.
Switch piano flush type one way 5 amps SP complete all as specified and directed.
Switch piano flush type one way 15 amps SP complete all as specified and directed.
Socket outlet 3 pin 5 amps flush type complete all as specified and directed.
Switch Socket multipurpose 2 in 1, 6 pin 5 and 15 amps controlled by one switch flush type universal.
Ceiling rose 65 x 50mm three terminals complete all as specified and directed.
Ceiling fan regulator electronic type 5 stage speed variation,socket type is size, ISI marked complete all as specified and directed.
Ceiling fan modular regulator electronic type 5 stage speed variation,socket type is size, ISI marked complete all as specified and directed .
Lamp holder/batton holder/angle holder insulated body(Metal ring) with back bakelite plate suitable for batten fittings, complete all as specified and directed.
Round shape 18 watts 220 volts AC, Recessed type with high efficiency PMMA diffuser soft glare free light complete with drivers, holders, LED lamp suitable for roof ceiling including connecting up with three core flexible copper conductor cable of suitable size, complete all as specified and directed. Make - Havells/ Polycab/ Crompton/ Wipro/ HPL/BENLO.
LED tube light fitting 20 watt, 230 volt,box type complete bipin holders, connector,mounted on PVC block and retro LED rod of 20 watt with aluminium heat sink on back of LED rod power factor > 0.9 complete with all accessories internally pre wired and including connecting up with three core twisted flexible copper conductor cable with suitable size mounting on rectangular PVC black complete all as specified and directed,LED tube rod ,make :Wipro ,Cat Part No: D612065 and LED tube light batten ,make :Wipro , Cat Part No : PO8120 or technocommerically equivalant make of Crompton/Philips/Polycab/HPL/BENLO. Note: (i) Contractor shall produce LM 79 & LM 80 test report form OEM owned NABL accredited laboraory. (ii) Contractor shall give gurantee of complete fitting/ fixtures for minimum of 2 years form the date of completion. (iii) Contractor shall conduct the inspection of company representative at site before installation of fittings/fixtures at no extra cost. (iv) Contractor shall arrange 70 % material at site for approval of GE before incorporation in the work.
LED Bulk head Sirius Series 10 watt LED light, Make - Wipro Cat Part No. DA11027 or technocommerically equivalent make of Havells/Bajaj/Syska.
Sheet metal enclosures distribution boards, double door ,VTPN, 415 volts 4 ways (one incoming three phase & twelve out goings single phase )for MCCB & MCB,s comprising three phase four wire copper strip bus bar of appropriate capacity complete all as specified and directed and comprising of the following a) MCCB FOUR POLE 100 AMPS AC 415 VOLTS 25 KA=01 NO (for incoming ) (b) MCB SP 06- 40 amps = 12 Nos (for outgoings) . Note :- (i)The DB shall be VTPN series of Make : Schneider ,cat part no: A9HVD04L or equivalent make of L&T/ ABB/ Legrand/BENLO . (ii) The DB shall be flush fixed and making good the disturbed surface matching with existing specifications shall be part of job at no extra cost. (iii)connection of the MCCBs/ MCBs with cable shall be made through appropriate size pin /bottle type thimble properly crimped. (iv) All the vacant holes of the DB shall be provided with blank plates of appropriate size. (v) Double continuous earth wire shall be provided for each three phase DB from earthing mains dolly. (vi) cutting chasing shall be part of job at no extra cost .
Sheet metal enclousre for TPN DBs 4 way when MCB to be used double door powder coated factory made flush fixed complete with 200 amps rated bus bar 415 volts three pahse and neuton 4 way complete all as specified and directed.
Sheet metal enclousre for DBs when MCB to be used double door powder coated factory made flush fixed complete with 200 amps rated bus bar 240 volts single phase 12 ways complete all as specified and directed.
Sheet metal enclousre for DBs when MCB to be used double door powder coated factory made flush fixed complete with 200 amps rated bus bar 240 volts single phase 08 ways complete all as specified and directed.
MCB TPN 63 amps 415 Volt 'B' series complete all as specified and as directed.
MCB SPN 63 amps 240 Volt 'B' series complete all as specified and as directed.
MCB SPN 6 to 32 amps 240 Volt 'C' series complete all as specified and as directed.
MCB SP 6 to 32 amps 240 Volt 'B' series complete all as specified and as directed.
Submain wiring in and including PVC conduit 1.8 mm thick ,25 mm dia with two run of PVC insulated, unsheathed multistranded copper conductor of 4 sqmm(FRLS) and one run of PVC insulated,unsheathed multistranded copper conductor 4 sqmm (green in colour) for earth continuity conductor and connected to common earth dolly with thimble etc including taking down old U/S brunt sub main wiring from wooden battens, complete all as specified and directed. (Two run of 4 sqmm plus one run 4 sqmm of earth wire will be measured as 1RM) Note: (a) Insulation test of point wiring (b) colour coding is to be maintained .(Ph-Red, N-Black,Earth- Green)
Submain wiring in and including PVC conduit 1.8 mm thick ,25 mm dia with two run of PVC insulated, unsheathed multistranded copper conductor of 6 sqmm(FRLS) and one run of PVC insulated,unsheathed multistranded copper conductor 6 sqmm (green in colour) for earth continuity conductor and connected to common earth dolly with thimble etc including taking down old U/S brunt sub main wiring from wooden battens, complete all as specified and directed. (Two run of 6 sqmm plus one run 6 sqmm of earth wire will be measured as 1RM) Note: (a) Insulation test of point wiring (b) colour coding is to be maintained .(Ph-Red, N-Black,Earth- Green)
Submain wiring in and including PVC conduit 1.8 mm thick ,32 mm dia with two run of PVC insulated, unsheathed multistranded copper conductor of 10 sqmm(FRLS) and one run of PVC insulated,unsheathed multistranded copper conductor 10 sqmm (green in colour) for earth continuity conductor and connected to common earth dolly with thimble etc including taking down old U/S brunt sub main wiring from wooden battens, complete all as specified and directed. (Two run of 10 sqmm plus one run 10 sqmm of earth wire will be measured as 1RM) Note: (a) Insulation test of point wiring (b) colour coding is to be maintained .(Ph-Red, N-Black,Earth- Green)
Submain wiring in and including PVC conduit of dia as per requirment with four run of PVC insulated, unsheathed multistranded copper conductor of 10 sqmm(FRLS) and one run of PVC insulated,unsheathed multistranded copper conductor 10 sqmm (green in colour) for earth continuity conductor and connected to common earth dolly with thimble etc including taking down old U/S brunt sub main wiring from wooden battens, complete all as specified and directed. (Four run of 10 sqmm plus one run 10 sqmm of earth wire will be measured as 1RM) Note: (a) Insulation test of point wiring (b) colour coding is to be maintained .(Ph-Red, N-Black,Earth- Green)
Earthing complete with galvanized steel earth plate electrode 600x600x6mm thick buried directly in the ground (earth pit not less than 2.25 mtr deep below the normal ground level ) with top edge of plate not less than 1.5 mtr below the normal ground level connected to galvanized iron wire 4mm dia as earth lead by means of nuts bolts,washers of GI upto test point,GI tubing light grade 15mm bore protection pipe and GI watering pipe 20mm light grade with funnel and wire mesh ,charcoal and salt,40mm thick pre-cast RCC M-15 (nominal mix) cover reinforced with XPM weight not less than 4 kg /sqm with suitable handle of 6mm dia MS bar and angle iron 40x40x3mm frame for cover ,PCC M-15 (nominal Mix) pit,excavation and earth work in any type of soil and removing surplus soil to a distance n.exc.50m) and connecting, Testing on complition, Complete all as specified and shown on Electrical Plate No 3 of SSR-2009 Part-1. complete all as specified and directed. Notes:- 1. Earth lead & protection pipes length upto & including 7.50 mtr is included in the quoted rate. 2. Soil should be free from stone, boulders, aggregate, gravels etc.
Modular metal sunken box 1&2 module, complete all as specified and directed.
Modular metal sunken box 3 module, complete all as specified and directed.
Modular metal sunken box 4 module, complete all as specified and directed.
Modular metal sunken box 6 module, complete all as specified and directed.
Modular white cover plate with frame 1 module, complete all as specified and directed.
Modular white cover plate with frame 2 module, complete all as specified and directed.
Modular white cover plate with frame 3 module, complete all as specified and directed.
Modular white cover plate with frame 4 module, complete all as specified and directed.
Modular white cover plate with frame 6 module, complete all as specified and directed.
Recess mounting LED 2X2 luminaire light fitting 36 watt complete with all accessories internally pre-wired and including connecting up with twin core twisted flexible copper conductor cable of 1.5 Sq mm with suitable size of 36 watt complete as specified and directed at site. make : Cat part No :-STARTO2X2PLR36WLED840MOD of Havells or technocommerically equivalent make of philips/crompton/BENLO
Surface mounting LED downlighter with white power coated aluminium housing with integrated electronic driver 15 watt in repair, complete with all accessories internally pre-wired and including connecting up with twin core twisted flexible copper conductor cable of 1.5 Sqmm with suitable size of 15 watt, complete all as specified and directed. Make : Havells,cat part no:ENDURANEOHESURFACEDLS15WLED84OS or technocommerically equivalant make of Crompton/Philips/BENLO .
Street light fitting for building security light made up of pressure die cast aluminium housing with IP65 protection of 35 watts LED Cool Daylight complete fitted on bldg with and including brackets made out of 40 mm dia GI pipe medium grade 1.5 in length long with suitable size of 2 nos MS flat clamps FI 25 x 3 mm including nuts,bolts including connecting up with PVC copper conductor wire 1.5 sqmm s/c from security light to ceiling rose etc, complete all as specified and directed,make: Havells ,cat part no:ENDURACITLITYEPLATPLUSSL35WLED757SASYBOPC or technocommerically equivalant Philips/Crompton/BENLO. Note: (i) Contractor shall produce LM 79 & LM 80 test report from OEM owned NABL accredited laboraory. (ii) Contractor shall give gurantee of complete fitting/ fixtures for minimum of 2 years from the date of completion. (iii) Contractor shall conduct the inspection of company representative at site before installation of fittings/fixtures at no extra cost. (iv) Contractor shall arrange 70% material at site for approval of GE before incorporation in the work.
Note:- The contract sum arrived after deduction of amount of Sch of credit as listed in tender Documents.
TESLA ENGINEERS & BUILDERS
Manminder Singh and Co
M/S RAJESH SHARMA & CO.
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .