Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.1 CrAccepted-AOC | ₹1.1 Cr | L1 | Accepted-AOC L1 |
| 2 | L2₹1.2 Cr+₹7.1 L (6.32%)Rejected-Finance 94 PHEARS LANE 1ST FLOOR KOL 700012 | KOLKATA | KOLKATA | WEST BENGAL | 700012 | ₹1.2 Cr+₹7.1 L (6.32%) | L2 | Rejected-Finance L2 |
| 3 | L3₹1.3 Cr+₹18.9 L (16.8%)Rejected-Finance | ₹1.3 Cr+₹18.9 L (16.8%) | L3 | Rejected-Finance L3 |
| 4 | L4₹1.4 Cr+₹31.1 L (27.5%)Rejected-Finance | ₹1.4 Cr+₹31.1 L (27.5%) | L4 | Rejected-Finance L4 |
| 5 | L5₹1.5 Cr+₹32.5 L (28.8%)Rejected-Finance 19B PANKAJINI CHATTERJEE ROAD CHARU MARKET KOLKATA WEST BENGAL 700033 UDYAM WB 10 0047115 | KOLKATA | WEST BENGAL | 700033 | ₹1.5 Cr+₹32.5 L (28.8%) | L5 | Rejected-Finance L5 |
Tender Value
Refer Docs
EMD Value
₹3.4 L
Closing Date
21 Dec 2020, 11:00 amClosed
SUPERINTENDING ENGINEER, P.W.DTE.
Office of the Superintending Engineer, Kolkata Health Circle, P.W.Dte., 1st Floor, KIT Building, P-16, India Exchange Place Extension, Kolkata - 700 073
Construction of B Plus G Plus10 Storied Building as Administrative cum Academic Building for the West Bengal University of Health Sciences at Salt Lake, Kolkata. Fire Fighting Work.
2020_WBPWD_305977_1
WBPWD/SE/KHC/NIQ-02/2020-2021
Open Tender
CIVIL WORKS
Item Rate
365 days
Kolkata
Please refer Tender documents.
4 documents required · 4 mandatory
₹3.4 L
Yes
22 Mar 2021
24 Nov 2020
23 Dec 2020
24 Nov 2020
21 Dec 2020
24 Nov 2020
Amount
(A) FIRE WATER PUMPING SYSTEM :- Supply, erection, testing & commissioning of Electrical Motor Driven Main Pump, Centrifugal Horizontal Type, with gland packing capable of deliver 2850 LPM at 88 MWC. The pump shall be coupled with TEFC motor of suitable KW with speed of 2900 RPM with all accessories and complete set shall mounted on common base frame. The quoted rate shall include fixing of coupling, coupling guard and foundation bolts etc. Civil foundation will be client's scope.
Supply, erection, testing & commissioning of Diesel Engine driven common standby pump, horizontal centrifugal type, suitable for automatic operation. The duty parameters of standby fire pumps shall be 2850 LPM at 105 MWC. The pump shall be coupled with radiator cooled diesel engine of speed 1800 RPM with auto starting mechanism and shall be equipped with other accessories as required including fuel tank(fabricated from 3 mm MS sheet, painted with two coates of synthetic enamel paint over a coat of primer) of capacity adequate to sustain continuous pump operation for 4 hours. The tank shall be fitted with magnetic oil level indicator, MH with cover, drain valve, air vent including structural support etc. Necessary battery to be supplied along with the diesel engine. Pump shall have C.I. casing, bronze impeller(dynamically balanced), SS-410 shaft with gland pack. Other accessories like common base frame, foundation bolts, flexible coupling, coupling guards etc to be supplied along with the pumps.The pump should be factory fitted on common base frame and to be erected at site on RCC foundation with proper anti vibration pad. RCC foundation shall be of owner scope. The pump shall be capable of furnishing not less than 150% of rated capacity at a head of not less than 65% of the rated head, The shut off head shall not exceed 120% of rated head.
Supply, erection, testing & commissioning of electric motor driven Jockey Pump, vertical inline type, suitable for operation on 415 volts ±10%, 3 phase, 50 Hz AC supply. The duty parameter of jockey pump shall be 180LPM at 105 MWC. The pump shall coupled to squirrel cage induction motor, TEFC type having suitable KW with speed of 2900 RPM. The pump components shall made of stainless steel with gland pack arrangement. Necessary accessories with foundation bolts etc to be supplied to complete the erection. Foundation required to erect the pump shall be of owner's scope.
Supply, Erection, testing & commissioning of compartmentalised common control panel for Electrical Motor driven pumps as per technical specification attached with this tender document. All components shall be housed in a common cubicals made of 16 swg. M.S. sheet with required stiffners(if required). The panel shall be powder quoted of approved colour both inside and out side. The pane shall have both bottom and top cable entry provisions and panel shall be mounted on pedestal of 300mm height. The panel should have sufficient(min. 6 nos per pump set) NO / NC contacts for extending the status of fire pumps to the fire alarm panel.
Supply, laying, testing & commissioning of FRLS, PVC outer sheath, steel armoured, aluminium / copper conductor, 1100 Volt Grade power cables with gland etc. The cable shall be laid in tray / hume pipe / in trenches / on walls / floors etc as required. Cables laid out doors shall include the price of earth excavation providing brick and sand protection, refilling and compacting the earth. 3C x 70 sq.mm YFY for main pump
2C x 1.5 sq.mm for instrumentation
4C x 10 sq.mm YFY for Jockey Pump
10C x 1.5 sq.mm YFY for Diesel Pump
Supply & installation of dial type Pressure Gauge of suitable pressure range, fitted with dampner arrangement and isolation ball valve as shown in respective drawing. The diameter of dial shall be 150 mm preferably filled up with glyserine. All other necessary fittings to be supplied to erect the gauge on pump header.
Supply and installation of Pressure Switches, SPDT type, of suitable range, fitted with dampner arrangement and isolation ball valves as shown in respective drawing for pump automation. All other required fittings to be supplied to erect the pressure switch on pump delivery header.
Supply, erection and testing of heavy grade(class-C) pipes conforming to IS-1239 / IS-3589 including all fittings viz. tees, elbows, reducers, union, flanges, rubber gaskets, GI nuts bolts, washer and structural steels for pipe supports. Hanger support with anchor fasteners and clamps shall be supplied to fix the pipes on ceiling wall etc. including supporting/fixing the pipe on floor / wall /ceiling with clamps, hangers (using anchor fastners) as per specification. Cutting of floors, walls etc and making it good after erection of pipes shall be of vendor's scope. Necessary painting with 2 coats of primer and 2 coats of synthetic enamel paints to be done and supply of paints shall be with vendor's scope. 200 mm NB x 6 mm thk
Supply,Installation, testing & commissioning of CI Gate Valve as pe IS:14846 (PN 16) with matching flanges complete with nuts & bolts. Size 200 mm NB
Size 150 mm NB
Size 65 mm NB
Size 50 mm NB
Size 25 mm NB
Supply, installation, testing & commisssioning of swinging type CI Non return Valve as per IS:5312(PN16 rating) with matching flanges, bolts, nuts and gaskets. Size 200 mm NB
Size 150 mm NB
Size 65 mm NB
Size 25 mm NB
Supply, installation, testing & commissioning of CI Globe Valve as per IS:9338(PN10 rating) with matching flanges, bolts, nuts and gaskets. Size 100 mm NB
Supply,Installation, testing & commisssioning of CI Foot valve with Strainer Size 200 mm NB
Size 80 mm NB
Supply & installation of GM / SS 3 way Fire Brigade Inlet with 63 mm dia instantaneous type coupling and 150 dia flanged outlet. Each inlet coupling shall be without built in check valve. The inlets shall conform IS:904.The inlet connection shall be mounted on fire water reservoir.
Supply & installation of GM / SS Fire Brigade Draw out connection with necessary foot valve strainer etc.
HYDRANT SYSTEM Supply, erection, and testing of MS heavy grade pipes conforming to IS:1239 / IS:3589 with accessories including all fittings viz tees, elbows, reducers, flanges, rubber gaskets, G.I. nuts, bolts and washers.The scope includes excavation of all kind of soil, refilling, ramming, shoring, removing the excavated surplus material, providing adequate support to the pipe and making it good. Rate shall include for dewatering, if necessary, to execute the work. The top of pipe shall not be less than 1.0 m below ground level at any point. Wrapping and coating to be done by applying protective primer @ 100 gm / sqm, thereafter wrapping with with 2 layer of coating materials of 2 mm thick by thermo fusion process. Overlap of coating shall be maintained at 25mm. 150 mm NB
Supply, erection and testing of heavy grade(class-C) pipes conforming to IS-1239 / IS-3589 including all fittings viz. tees, elbows, reducers, union, flanges, rubber gaskets, GI nuts bolts, washer and structural steels for pipe supports. Hanger support with anchor fasteners and clamps shall be supplied to fix the pipes on ceiling wall etc. including supporting/fixing the pipe on floor / wall /ceiling with clamps, hangers (using anchor fastners) as per specification. Cutting of floors, walls etc and making it good after erection of pipes shall be of vendor's scope. Necessary painting with 2 coats of primer and 2 coats of synthetic enamel paints to be done and supply of paints shall be with vendor's scope. 150 mm NB
Supply, installtion, testing and commissioning of swinging type CI Non return Valve as per IS:5312 with SS trim including matching flanges, nuts, bolts and gaskets. Size 150 mm NB
Size 100 mm NB
Supply, installation, testing & commissioning of CI Gate Valve as per IS:14846 (PN 16) including matching flanges, nuts, bolts and gaskets. Size 150 mm NB
Supply, installation, testing & commissioning of CI Butterfly valve as per BS :5155 (Wafer type) with matching flanges,nuts & bolts and gasket. 150 mm NB
Supply and installation of Globe Valves in Gun Metal Construction to IS: 778 with screwed ends 25 NB size
Supply, installation of automatic 25 NB Air Release Valve
Supply & installation of GM / SS oblique type single headed Landing valve with 80 mm inlet and 63 mm outlet GM / SS instantaneous male coupling with rubber cap and chain conforming to IS : 5290 including matching flanges, gasket, nuts and bolts.
Supply & installation of GM / SS oblique type single headed Hydrant valve with 80 mm inlet and 63 mm outlet GM / SS instantaneous male coupling with rubber cap and chain conforming to IS : 5290 including matching flanges, gasket, nuts and bolts.
Supply & installation of GM / SS branch pipe with 20 mm nozzle conforming to IS : 903.
Supply & installation of 63 mm dia reinforced rubber line hose pipe in 15 m length conforming to IS : 636 Type II ISI marked with GM/SS male and female instantaneous coupling conforming to IS 903 wounded with 18 SWG copper wire.
Supply & installation of hose box, fabricated from 16 SWG CRCA sheet, double door with lockable arrangements to accommodate 2 RRL hose of 15 m length and one branch pipe painted white inside and red outside with one key. (750x600x250 mm).
Supply & installation of swinging type hose reel drum fabricated from 14 SWG CRCA sheets painted with red colour stove paint 2 coats over 1 coat of primer. The length of hose shall be with 30 m with 20 mm dia. Working pressure rating shall be 18 kg/sq. The pipe shall be coupled with SS/GM self closing shut – off nozzle of 5 mm outlet.
Supply & installation of GM / SS 3 way Fire Brigade Inlet with 63 mm dia instantaneous type coupling and 150 dia flanged outlet. Each inlet coupling shall be with built in check valve. The inlets shall conform IS:904.The inlet connection shall be mounted on external network.
Supply & installation of GM / SS 2 way Fire Brigade Inlet with 63 mm dia instantaneous type coupling and 100 dia flanged outlet. Each inlet coupling shall be with built in check valve. The inlets shall conform IS:904.The inlet connection shall be mounted on wet riser.
Supply & installation of dial type Pressure Gauge of suitable pressure range, fitted with dampner arrangement and isolation ball valve as shown in respective drawing. The diameter of dial shall be 150 mm preferably filled up with glyserine. All other necessary fittings to be supplied to erect the gauge on top of the riser.
AUTOMATIC SPRINKLER SYSTEM Supply, erection and testing of heavy grade(class-C) pipes conforming to IS-1239 / IS-3589 including all fittings viz. tees, elbows, reducers, union, flanges, rubber gaskets, GI nuts bolts, washer and structural steels for pipe supports. Hanger support with anchor fasteners and clamps shall be supplied to fix the pipes on ceiling wall etc. including supporting/fixing the pipe on floor / wall /ceiling with clamps, hangers (using anchor fastners) as per specification. Cutting of floors, walls etc and making it good after erection of pipes shall be of vendor's scope. Necessary painting with 2 coats of primer and 2 coats of synthetic enamel paints to be done and supply of paints shall be with vendor's scope. 150mm NB
Supply, installation, testing & commissioning of Sprinkler Head Pendent type
Supply, installation, testing & commissioning of Sprinkler Head Upright type
Supply, installation, testing & commissioning of 1inch dia 1.2m long unbraided Flexible pipe for fixing sprinkler
Supply,Erection and testing of Installation Control Valve complete with trims & gong. Size 150 mm NB
Supply, installation, testing & commissioning of CI Gate Valve as per IS:14846 (PN 16) including matching flanges, nuts, bolts and gaskets. Size 150 mm NB
Supply, installation, testing & commissioning of CI Butterfly valve as per BS :5155 (Wafer type) with matching flanges,nuts & bolts and gasket. Size 150 mm NB
Size 100 mm NB
Size 80 mm NB
Size 65 mm NB
Supply, installtion, testing and commissioning of swinging type CI Non return Valve as per IS:5312 with SS trim including matching flanges, nuts, bolts and gaskets. Size 150 mm NB
Size 100 mm NB
Size 80 mm NB
Size 65 mm NB
Supply & installation of Flow Switch
Supply & installation of automatic 25 NB Air Release Valve
Supply & installation of GM / SS Globe Valve to IS: 778 with screwed ends. Size 40NB
Size 25NB
Supply & installation of dial type Pressure Gauge of suitable pressure range, fitted with dampner arrangement and isolation ball valve as shown in respective drawing. The diameter of dial shall be 150 mm preferably filled up with glyserine. All other necessary fittings to be supplied to erect the gauge on top of the riser.
PORTABLE EXTINGUISHERS Supply & fixing of 5 Kg dry power extinguisher consisting of welded MS cylindrical body with discharge valve, nozzle & CO2 cartage and hanging arrangement complete conforming to IS:2171
Supply & fixing of 9 Litre Water type CO2 (ISI marked) extinguisher including all accessories with wall bracket & raw plug conforming to IS:940
Providing & fixing 9 Litre Foam type (ISI marked) extinguisher including all accessories with wall bracket & raw plug confirming to IS:10204
Supply & fixing of 6.8 Kg carbon-di-oxide fire extinguishers (ISI Marked) consisting of welded MS cylindrical body, squeeze, lever discharge valve, fitted with internal discharge tube, high pressure discharge hose, discharge nozzle, suspension bracket, finished externally with red enamel paint and fixed to wall with brackets with rawlplug/ dash fastners complete with internal charge conforming to IS:2878.
SIGNAGES Supply and installation in position the "FIRE EXIT" Sign with luminicent colour having size 300 x 100 mm.
Supply and fixing in position the signages " FIRE ORDER" contain the following matter on 3 mm thick "Opaque" PVC foam board of computerised cut, PVC non-reflective self adhesive vinyle painted foam board of size 1200 x 1000 mm. (a) ALERT THE SECURITY AT SECURITY ROOM BY ACTUATING MANUAL CALL POINT LOCATED AT STRATEGIC LOCATION. (b) EVACUATE THE OCCUPANTS BY USING FIRE EXIT AND EMERGENCY EXITS ONLY AND ASSEMBLE AT ASSEMBLY POINTS. (c) BE CALM AND DO NOT GET PANIC, WALK DO NOT RUN (d) IF POSSIBLE TRY TO EXTINGUISH FIRE BY USING NEAREST / SUITABLE PORTABLE EXTINGUISHER OR WATER FROM NEAREST WET RISER.
Supply and fixing signage with printed " IN CASE OF FIRE, DO NOT USE LIFT. USE STAIRS ONLY" OF 1.5 cm height letters in red with white background. The size of the board shall be 300 x 250 mm and shaall be fixed at the height of 2 mtrs.from finished floor near Manual Call Point.
NILEX FIRE PROTECTION SYSTEMS
SAI CONCERN
EASTERN TRAFFIC SAFETY SOLUTIONS PRIVATE LIMITED
BALAJI FIRE PROTECTION SYSTEMS
M/S M. B. ENTERPRISE
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .