| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹12.7 CrAccepted-AOC | ₹12.7 Cr | L1 | Accepted-AOC BEING LOWEST |
| 2 | L2₹13.7 CrRejected-Finance NOT SPECIFIED | ₹13.7 Cr | L2 | Rejected-Finance Being not lowest |
| 3 | L3₹15.2 CrRejected-Finance L 87 STREET NO 7C MAHIPALPUR EXTENSION NEW DELHI 110037 | NEW DELHI | NEW DELHI | DELHI | 110037 | ₹15.2 Cr | L3 | Rejected-Finance Being not lowest |
| 4 | L4₹15.7 CrRejected-Finance 501 SHANTI RESIDENCY II KRUSHNA NAGAR NR NARDAI BRAHM SAMAJ JAMNAGAR 361 006 | JAMNAGAR | GUJARAT | 361006 | ₹15.7 Cr | L4 | Rejected-Finance Being not lowest |
| 5 | L5₹16.2 CrRejected-Finance | ₹16.2 Cr | L5 | Rejected-Finance Being not lowest |
| Sl No | Description | Qty | Unit | Jeet Construction L1 | Vijay Construction Co L4 | Parth Infrastructure Pvt. Ltd. L5 | NSC Projects Pvt. Ltd. L3 | United Sales Corporation L2 |
|---|---|---|---|---|---|---|---|---|
| .01SCHEDULE 'A' PART IA & IB is not prepriced by MES and prepriced rates indicates 0.00 under col 5 signified this fact only . (TO BE QUOTED BY THE CONTRACTOR) Bidders shall insert their lumpsum amount in BOQ Ser No 1 to 4 in the Green coloured field under Col-6 only. Note : The quoted rate against is deemed to included for the provisions contained in Sch 'A' Notes. Ref Sch A Notes complete before quoting these items. Structural design and structural drawings for super structure and foundations for the building/structure shall be prepared to comply with the provisions for design and analysis of RCC structures as per latest editions relevant IS Codes | ||||||||
| .02Schedule ‘A’ Part IA PRE-ENGINEERED BUILDING (TO BE QUOTED BY THE CONTRACTOR) | ||||||||
| 1.00 | Lumpsum price worked out for PRE-ENGINEERED BUILDING (PEB) as listed in Schedule ‘A’ Part IA complete all as specified and directed. | 1 | Lumpsum | 8,80,00,000 ₹8.8 Cr | 11,89,49,111 ₹11.9 Cr | 11,85,52,516 ₹11.9 Cr | 10,21,16,222 ₹10.2 Cr | 9,54,00,000 ₹9.5 Cr |
| 1.01Schedule ‘A’ Part IB BUILDINGS/ STRUCTURES (TO BE QUOTED BY THE CONTRACTOR) | ||||||||
| 2.00 | Lumpsum price worked out for RCC Water tank staging 5m height for 4000 Litre capacity as listed in Schedule ‘A’ Part IB complete all as specified and directed. | 1 | Lumpsum | 4,00,000 ₹4 L | 4,20,000 ₹4.2 L | 2,35,000 ₹2.4 L | 5,00,000 ₹5 L | 1,75,000 ₹1.8 L |
| 3.00 | Lumpsum price worked out for Substation Building as listed in Schedule ‘A’ Part IB complete all as specified and directed. | 1 | Lumpsum | 10,00,000 ₹10 L | 14,87,750 ₹14.9 L | 16,33,920 ₹16.3 L | 25,00,000 ₹25 L | 20,00,000 ₹20 L |
| 4.00 | Lumpsum price worked out for Changing room, cafeteria, ladies/ gents/ staff toilets building as listed in Schedule ‘A’ Part IB complete all as specified and directed. | 1 | Lumpsum | 20,00,000 ₹20 L | 22,50,000 ₹22.5 L | 28,97,300 ₹29.0 L | 51,60,167 ₹51.6 L | 20,00,000 ₹20 L |
| 4.01NOTE: Schedule ‘A’ Part II to XIII under Ser No. 5.00 to 16.00 are prepriced by MES. Bidders shall insert their lumpsum amount in the green coloured field under Col-6 only. | ||||||||
| 5.00 | Lump sum price worked out for EXCAVATION, EARTH WORK AND SITE CLEARANCE as listed in Sch 'A' Part II | 1 | Lumpsum | 21,76,410 ₹21.8 L | 25,00,000 ₹25 L | 22,76,700 ₹22.8 L | 19,92,140.35 ₹19.9 L | 25,00,000 ₹25 L |
| 6.00 | Lump sum price worked out for INTERNAL WATER SUPPLY as listed in Sch 'A' Part III | 1 | Lumpsum | 41,185 ₹41,185 | 45,000 ₹45,000 | 33,350 ₹33,350 | 38,250 ₹38,250 | 35,000 ₹35,000 |
Tender Value
₹14.2 Cr
EMD Value
₹10.4 L
Closing Date
18 Aug 2025, 6:00 pmClosed
CE(AF) GANHDINAGAR
LEKAWADA, PATIA CHOWK NEAR CRPF CAMPUS, CHILODA GANDHINAGAR
PROVN OF HANGER FOR HU COMPLEX AT AF STN JAMNAGAR
2025_MES_713762_1
86285
Open Tender
Civil Works
548 days
GE(P) (AF) JAMNAGAR
AS PER TENDER AND NIT DOCUMENTS
6 documents required · 6 mandatory
₹3,000
GE(P) (AF) JAMNAGAR
₹10.4 L
15 Jan 2026
11 Jun 2025
21 Aug 2025
11 Jun 2025
18 Aug 2025
21 Jul 2025
15 Jun 2025 - 18 Jun 2025
Amount
Schedule ‘A’ Part IA PRE-ENGINEERED BUILDING (TO BE QUOTED BY THE CONTRACTOR)
Lumpsum price worked out for PRE-ENGINEERED BUILDING (PEB) as listed in Schedule ‘A’ Part IA complete all as specified and directed.
Schedule ‘A’ Part IB BUILDINGS/ STRUCTURES (TO BE QUOTED BY THE CONTRACTOR)
Lumpsum price worked out for RCC Water tank staging 5m height for 4000 Litre capacity as listed in Schedule ‘A’ Part IB complete all as specified and directed.
Lumpsum price worked out for Substation Building as listed in Schedule ‘A’ Part IB complete all as specified and directed.
Lumpsum price worked out for Changing room, cafeteria, ladies/ gents/ staff toilets building as listed in Schedule ‘A’ Part IB complete all as specified and directed.
NOTE: Schedule ‘A’ Part II to XIII under Ser No. 5.00 to 16.00 are prepriced by MES. Bidders shall insert their lumpsum amount in the green coloured field under Col-6 only.
Lump sum price worked out for EXCAVATION, EARTH WORK AND SITE CLEARANCE as listed in Sch 'A' Part II
Lump sum price worked out for INTERNAL WATER SUPPLY as listed in Sch 'A' Part III
Lump sum price worked out for INTERNAL ELECTRIFICATION , LAN NETWORK & COOLING APPLICANCES as listed in Sch 'A' Part IV
Lump sum price worked out for ROAD/ PATH/ CULVERT/ APRON as listed in Sch 'A' Part V
Lump sum price worked out for AREA DRAINAGE as listed in Sch 'A' Part VI
Lump sum price worked out for SEWAGE DISPOSAL as listed in Sch 'A' Part VII
Lump sum price worked out for EXTERNAL WATER SUPPLY as listed in Sch 'A' Part VIII
Lump sum price worked out for EXTERNAL ELECTRIFICATION as listed in Sch 'A' Part IX
Schedule 'A' Part X - BLANK PAGE -
Lump sum price worked out for DG SET as listed in Sch 'A' Part XI
Lump sum price worked out for LIGHTENING PROTECTION as listed in Sch 'A' Part XII
Lump sum price worked out for DEMOLITION as listed in Sch 'A' Part XIII
SCHEDULE 'A' PART - XIV MISCELLANEOUS ITEMS is not prepriced by MES and prepriced rates indicates 0.0 under column 5 signifies this fact only. Bidder shall insert their rates in Green filed under Col-6.
INTERNAL ELECTRIFICATION , LAN NETWORK & COOLING APPLIANCES
Supply and fixing Anti-suicide fan rod of standard length (18") made of corrosion resistance mildsteel/aluminium alloy with load sensitive auto-detach mechanism caliberated to release above 25 Kg load, complete with necessary fittings all as specified and directed.
Supply and fix of 70W LED Flood Light with System Lumen Efficacy≥100 Lm/W operating Voltage between 140-270Vac, Driver will have cut off at > 300 Vac, Power Factor more than 0.95%, LED CCT 5665±355K as per ANSI BIN, LED Driving Current < 70% of rated maximum forward current, Luminaire intergal driver with 5KV surge protection, Over Load Protection, No Load Protection and BIS Marking (R no. for Driver), Driver Certifcation IEC 64347-2-13 IS(15885), Driver should be concealed under IP66, Overall electrical efficency more than 90%, Driver electrical efficiency will be > 85% connecting with PVC copper cable of size 3x1 sqmm as per IS 10322 at Least 2 Year on site warranty without any condition complete all as specified and directed. (FOR OUTSIDE ILLUMINATION OF HANGAR)
Supply and fix flame proof TPN 4 way distribution board for mounting MCBs/RCBOs, ELCB, etc. as per IS specification and CMRI approved, factory made fabricated out of cast aluminium alloy LM-06, grey eppoxy powder coated finish, fitted with DIN Channel neutral link, Earth links and 200 Amps rated bus bar. The DB shall be having IP-65 protection complete all as specified and directed. The DBs shall also be consisting and including of the following:- Incoming :- 01 No of 63 A TPN MCB Outgoing :- 12 Nos 6-32 A SP MCB
Supply and fix totally enclosed flame proof/ weather proof direct entry type switch socket and plug combined 32A, 415V, 4P+earth 5 pin in cast aluminum alloy LM-6 enclosure epoxy powder coated suitable for mounting on wall/ steel structure etc. duly tested and certified by CMRI-Dhanbad complete all as specified and directed.
Supply and fix flame proof and weatherproof- IP 66 distribution board for mounting MCCB as incoming and MCBs as outgoing as per IS specification and CMRI approved, factory made fabricated out of cast aluminium alloy LM-06, grey eppoxy powder coated finish, fitted with DIN Channel neutral link, Earth links with suitable size bus bar and cable terminals and internal wiring all as per make Shyam Cat part No. SSPL/110 or equivalent in approved makes suitable for incoming cable of 95Sqmm x 3.5 core size complete all as specified and directed. The DB shall also be consisting and including of the following:- Incoming :- 01 No of 160 A MCCB, 4P, 10 KA Outgoing :- (a) MCB 32 Amp, 4P, 10 KA - 04 Nos. (b) MCB SPN 16-32 Amps - 06 Nos.
Supply and fix double RJ11 telephone socket 1 module for laying CAT cables of LAN complete all as specified and directed.
Supply and fix RJ45 Cat 6 computer socket 1 module for laying CAT cables of LAN complete all as specified and directed.
Supply and fix blanking plate 2 module for laying CAT cables of LAN complete all as specified and directed.
Supply and fix solid state electronic type voltage stabilizer for automatic operation, single phase naturally air cooled indoor type and designed for input variation between 170 V to 250 V with output voltage stabilized at 230 V with accuracy of ± 2.5% and of capacity 1 KVA complete all as specified and directed.
EXTERNAL WATER SUPPLY
Supply and lay Ductile Iron pipe, S/S including specials, Class K-7 150 mm (4”) dia complete all as specified and directed
Supply and fix centrifugal, electric driven 5 HP three phase monoblock pump with speed not less than 3000 rpm, 400 V, size of the pump - 65x50 mm, discharge range ranging from 8.5 to 5.8 LPS, head range 20-36 m inclusive of starter and PCC foundation as per OEM recommendations all to complete satisfaction of Engr in Charge all as specifed and directed.
Material and labour for brick masonry valve chamber of size 900x900x900mm solid block masonry 200 mm thick over concrete foundation in PCC 1:4:8, D2, 100 mm thick and 50 mm thick PCC 1:2:4 type B1 in coping including 15 mm thick plastering in cement mortar 1:4 for internal surfaces 15 cm below normal ground level and inclusive of 3mm thick mild steel sheet cover and angle iron frame of size 40 mm x 40mm x 6mm including provision of suitable hold fasts to hold the frame, locking arrangement and lifting handle, duly painted with two coats of synthetic enamel paint, over a coat of red oxide primer complete all as specified and as directed.
EXTERNAL ELECTRIFICATION
Material and labour for removal of HT cable of size 95 sqmm x 3 core from trench including taking out PCC cable covers and stacking the PCC cable covers at the nearest location for joint inspection with the department so as to relay the same at the location as directed complete all as specified and directed.
Material and labour for removal of LT cable of size upto 185/300 sqmm x 3.5 core from trench including taking out PCC cable covers and stacking the PCC cable covers at the nearest location for joint inspection with the department so as to relay the same at the location as directed complete all as specified and directed.
Material and labour for relaying of HT cable of size 95 sqmm x 3 core in trenches including connecting and testing complete all as specified and directed.
Material and labour for relaying of LT cable of size up to 300 sqmm x 3.5 core in trenches including connecting and testing complete all as specified and directed.
Relaying only un-reinforced precast concrete cable cover, class HV as retrieved from trenches complete all as specified and directed.
Relaying only un-reinforced precast concrete cable cover, class LV as retrieved from trenches complete all as specified and directed.
B. OUTGOING: (i) MCCB 630 Amps, 415 V, 4 Pole 36 KA, 50 Hz with Ics = 100% Icu and thermal magnetic adjustable type including spreader terminals - set of 04 and 01 no. direct rotary handle as per OEM specifications - 01 No. Note: As outgoing cable is 2 runs of 400 sqmm 3.5 core cable, suitable size of extended bus bar must be provided duly fixed to spreader terminals of the MCCB. (ii) MCCB 320 Amps, 415 V, 4 Pole 36 KA, 50 Hz with Ics = 100% Icu and thermal magnetic adjustable type including spreader terminals - set of 04 and 01 no. direct rotary handle as per OEM specifications - 01 No. Note: Outgoing cable to be connected is of size 240 sqmm x 3.5 core. (iii) LED indicators - R/Y/B 240 V AC - 03 set of 03 indicators (for each incoming & outgoing feeders) (iv) Multifunction meter with accuracy class 1.0, Flush mounting 96 x 96 mm, CT/PT site programmable for measurement of V, A, PF, kW, kVA, Load hours and including suitable size CTs (set of 3) - 01 No. (01 No. for Incoming feeder)
(v) Single function 3 phase LED voltmeter with accuracy Class 1.0, Flush mounting 96 x 96 mm, Input voltage measurement range 50-520 VAC (P-P), CT/PT site programmable - 02 Nos. (Outgoing feeders) (vi) Single function 3 phase LED ammeter with accuracy Class 1.0, Flush mounting 96 x 96 mm, Input voltage measurement range 50-520 VAC (P-P), CT/PT site programmable and including suitable size CTs (set of 3) - 02 Nos. (Outgoing feeders) (vii) MCB SP 'C' series 10kA 06-32 Amps as protection for LED lamps (01 No. each for set of 03 Nos. LED lamps, multifunction and single function electronic measuring meters) and multifunction meter - 08 Nos. (viii) Control wiring with suitable size PVC insulated single core copper conductor cable for LED lamps, MFMs, etc. (ix) Miscellaneous: Nuts, Bolts, Washers, Ferul Numbers, Cable Ties, Tie Base, Copper PVC Control Wire, Power Wire, Copper, Thimbles, Panel Locks, I-Hooks, PVC Tape, Insulators, E-type, L-Type, Round Type, MCB Chanel, PVC Chanel, Connector Chanel, Connectors, Foam Ga - 01 Lot
Supplying, installing, testing and commissioning of 415 Volts, 3 Phase, 4 Wire factory fabricated and tested all as per existing IEC 61439 Part 1, floor mounted, IP 55 grade, INDOOR double door Type Tested Assembly (TTA) type LT cubical panel (busbars, terminals and functional units are all completely isolated from each other ie. incoming and outgoing switchgears, incoming and outgoing cable alleys and 3 phase & neutral busbar should be isolated from each other by assembling all in separate individual compartments) and made out of CRCA MS sheet duly powder coated with Seimens grey shade RAL 7032, dust and vermin proof with suitable size TPN PVC sleeved aluminium bus bar all as per L&T Make Ti Model or equivalent in Legrand Make Model-XL3 Panels/ Seimens Make Model-SIVACON/ABB Make Model-ArTu including angle iron base frame of suitable size duly mounted/ grouted on PCC foundation complete with the following accessories:- Note:- (i) The contractor has to submit design of the LT panel for approval of Engr in Charge prior to manufacturing of the same. (ii) As the incoming cable size is 400 sqmm x 3.5 core, necessary clamping/ supporting arrangements must be provided within the cubicle for vertical support to the cable so as to minimize stress on the switchgear's incoming and outgoing terminals produced to cable self weight. A. INCOMING: (i) MCCB 630 Amps, 415 V, 4 Pole 36 KA, 50 Hz with Ics = 100% Icu and thermal magnetic adjustable type including spreader terminals - set of 04 and 01 no. direct rotary handle as per OEM specifications - 01 No.
B. OUTGOING: (i) MCCB 200 Amps, 415 V, 4 Pole 25 KA, 50 Hz with Ics = 100% Icu and thermal magnetic adjustable type including spreader terminals - set of 04 and 01 no. direct rotary handle as per OEM specifications - 01 No. (ii) MCCB 100 Amps, 415 V, 4 Pole 25 KA, 50 Hz with Ics = 100% Icu and thermal magnetic adjustable type including spreader terminals - set of 04 and 01 no. direct rotary handle as per OEM specifications - 03 Nos. (01 No. spare) (iii) MCCB 63 Amps, 415 V, 4 Pole 25 KA, 50 Hz with Ics = 100% Icu and thermal magnetic adjustable type including spreader terminals - set of 04 and 01 no. direct rotary handle as per OEM specifications - 04 Nos. (iv) LED indicators - R/Y/B 240 V AC - 06 set of 03 indicators (for each incoming & outgoing feeders) (v) Multifunction meter with accuracy class 1.0, Flush mounting 96 x 96 mm, CT/PT site programmable for measurement of V, A, PF, kW, kVA, Load hours and including suitable size CTs (set of 3) - 01 No. (01 No. for Incoming feeder)
(vi) Single function 3 phase LED voltmeter with accuracy Class 1.0, Flush mounting 96 x 96 mm, Input voltage measurement range 50-520 VAC (P-P), CT/PT site programmable - 08 Nos. (Outgoing feeders) (vii) Single function 3 phase LED ammeter with accuracy Class 1.0, Flush mounting 96 x 96 mm, Input voltage measurement range 50-520 VAC (P-P), CT/PT site programmable and including suitable size CTs (set of 3) - 08 Nos. (Outgoing feeders) (viii) MCB SP 'C' series 10kA 06-32 Amps as protection for LED lamps (01 No. each for set of 03 Nos. LED lamps, multifunction and single function electronic measuring meters) and multifunction meter - 18 Nos. (ix) Control wiring with suitable size PVC insulated single core copper conductor cable for LED lamps, MFMs, etc. (x) Miscellaneous: Nuts, Bolts, Washers, Ferul Numbers, Cable Ties, Tie Base, Copper PVC Control Wire, Power Wire, Copper, Thimbles, Panel Locks, I-Hooks, PVC Tape, Insulators, E-type, L-Type, Round Type, MCB Chanel, PVC Chanel, Connector Chanel, Connectors, Foam Ga - 01 Lot
Disconnecitng all incoming and outgoing cable from LT Panel and shifting from existing location to new location including provision of PCC foundation for fixing LT panel, reconnecting all incoming and outgoing cables complete all as specified and directed.
Material and Labour for maintenance free Chemical earthing of technology 3 mtr long 17-20mm dia with 250 micron copper coating and UL listed. There should be terminal for connection of 150 x 150 x 6mm with 4 holes of 12mm dia alongwith bags of 25 Kgs each of earth enhancing compound. The chemical compound should be tested and certified by any NABL accredited laboratory with 95 percent carbon content. The testing laboratory should be an ISO 9001 and 14001 certified. The earth enhancing compound should be IEC 62321. The ph value of compound should be 7-8 Electrode should be duly tested and certified by CPRI, Govt of India for a min short circuit current of 25 kA rms for 1 Sec including necessary boring of suitable dia upto required depth in any type of soil for inserting copper rod and filling of chemicals and Poly plastic pit cover of material polymer body & cover dimensions 308mm (L) x 308mm (W) x 214mm (H) bearing capacity 7.5 Ton approved from NABL approved Lab complete all as specified and as directed.
NOTE : (i) Earthing is to be done infront of the Engr-in-Charge (ii) Test Results of earthing to be submitted by the contractor for all earthings. (iii) The Contractor shall have to give written guarante for maintenance earth resistance of less than 1.0 Ohm for the period of 10 years after certified date of completion and shall deposit Rs 2000/- per earting as security deposit for a period of 10 years (Ten Years) (iv) Failing to maintain resistance of earthing less than 1.0 Ohm , new earthing to be provided by the contractor with out any extra cost. (v) Necessary earth work, excavation shall be carried out in any type of soil strata, returning , filling in and making good the surounding area complete
DG SET
Supply, installation, testing and commissioning of Diesel Engine driven generating set of 400 KVA capacity 3 phase, 4 wire, 415 V, 1500 RPM AC power supply with power factor 0.8 coupled directly to alternator mounted on a common base plate complete with integral acoustic enclosures (should have sailent features) modular bolted construction and pure polyester based coating to ensure long life in all weather conditions and for outdoor application/ installation, integrated design thereby facilitating easy handling. The design of integral acoustic enclosure should be approved by National Physical laboratory as per Central Pollution Control Board (CPCB- 4+ compliant) latest regulations/norms with fuel tank, battery and standard accessories and PCC platform of appropriate dimension for acoustic enclousure 45 cm above ground level as recommended by manufacturer, and inclusive of tools and spares as provided by manufacturer including weather shade made with MS pipes minimum 80 mm dia and PVC sheet complete all as specified and as directed with the following specifications:
(A) ENGINE - Water cooled diesel engine of 1500 RPM capacity to match the 400 KVA alternator under NTP conditions with provision of 10% over load for 1 hour in every 12 hours running confirming to BS 5514/ IS 10001/10002. The Engine shall consist of the following :- (i) Fly wheel with starter ring (ii) Flexible coupling with guard (iii) Cooling fan (iv) Radiator with guard and water pump engine mounted (v) Dynamo of suitable capacity (vi) Air cleaner heavy duty dry (vii) Fuel injuction pump (viii) Radiator fan (blower type) with guard (ix) Mechanical governer (x) Fuel filter (mounted) (xi) Lubricating oil filters (mounted) (xii) 24 V self regulating alternator belt driven by engine (xiii) Exhaust silencer heavy duty residential type (xiv) Corrosion resistor /scale inhibitor (xv) Starter 12/24 V DC (xvi) Lubricating oil cooler (xvii) Lubricating oil pump (Gear type) (xviii) Turbo charger (xix) Exhaust piping (if provided) shall be insulated with asbestos rope duly cladded with aluminium sheet
(xx) Instrument panel complete with:- (a) Auto manual starting switch with key (b) Lubricating oil temperature gauge (c) Lubricating oil pressure gauge (d) Water temperature gauge (e) Battery charging ammeter (f) Battery charging indicating lamp (g) Hour meter with RPM indicator (h) Safety control against high temperture of water (j) Safety control against low lubricating oil pressure (k) Over speed stop with double driven adoptor
(B) BRUSHLESS ALTERNATOR - (i) Brushless Alternator coupled to engine indigeniously through a flexible coupling mounted on sturdy steel fabricated base frame suitable for mounting on a permanent foundation; alternator shall be confirming to BS -2613 or relevant of IS-4722/ IS 13364 (ii) Type - Self excited self regulated with automatic voltage regulator (iii) Rating - 400 KVA at 0.8 PF lagging 4 pole horizonal at NTP condition (iv) Speed - 1500 RPM (v) System - 415 V +/- 2.5 % AC 3 phase 4 wire 50 Hz. (vi) Connection - 4 wire star connected (vii) Enclosure - Screen protected drip proof (viii) Ventilation - Self ventilated (ix) Insulation - Insulation class H (C) CONTROL PANEL - The control panel shall consist of aluminium bas bar, bottom entry and exit of cables, current transformer, set of contor fuses, Multifunctional Meter which should display time, date, Volts, Frequency, Current, KW, KWH, PF, RPM, Cumulative Run Hours, Oil Pressure, Coolant Temp, Charging current (DC Amp Meter) mounted with Emergency OFF, factory made floor mounted, totally enclosed, epoxy powder coated suitable for 400 KVA DG Set including all necessary operating controlled devices as stated above and MCCBs as outgoing with protection fuse for panel instruments duly wired with flexible copper conductor cable and cable connection with lugs/thimbles complete as per latest IS/BS and all as specified and directed.
(D) ONE SET OF ACCESSORIES COMPRISING OF - (a) Battery :- Heavy duty battery two nos. 24 plates 12 V 180 AH (2 Nos) connected to the system fully charged including lead and battery terminals complete (E) Base plate :- Fabricated out of MS channel's ISMC of suitable size suitable for fixing of DG set all specified by the manufacturer (F) AMF PANEL - Separate floor mounted AMF Panel with incoming switchgear 630Amps MCCB thermal adjustable type suitable for connection of 2 runs of 400 sqmm 3.5 core cable suitable for 400 KVA DG Set factory made out of CRCA Steel 16 SWG Sheet, floor mounted type and front operated type, totally enclosed dust, damp and vermin proof, all doors and joints shall be suitable gasketed to form dust and vermin proof. The panel shall be powder coated minimum thickness of 50 microns, stove enameled paint finished after elaborate pre-treatment to form a long lasting characteristic. The control panel shall be complete in all respect with fuses, wiring and labels etc. The AMF panel should contain Woodward controller model No. Easy Gen 1500 with connected wiring and SCADA compatible PLC and SCADA Based GPRS modem and POL Sensor and all connected accessories:-
(a) Multifunctional meter digital (Amp+Volt+PF+Hz+KW+KWH) - 01 No (b) Alternator voltage monitor - 01 No (c) Main voltage monitor - 01 No (d) Ammeter DG Analog - 01 No (e) Voltmeter DG Analog -01 No (f) Power fuse link - 06 Nos (h) Power fuse base - 06 Nos (j) Man power contactor - 3 pole (k) DG Power contactor - 3 pole (l) Indicator lamp - 02 Nos (m) MCB (for control ckt) -10 Nos (n) Auxiliary Contactor - 02 Nos (o) Automatic battery 12 volt charge - 01 No (p) Terminal O/L relay - 01 No (q) Terminals (for control cable) - 06 Nos (r) One set of copper bus bar of suitable capacity
FIRE ALARM SYSTEM
Supply, installation, testing and commissioning of microprocessor based 1 loop capacity analogue Addressable Fire Alarm Control Panel with minimum 80 characters LCD display, 800 event plus 200 alarm log history events, QWERTY keypad for programming, the panel should be equipped with sufficient numbers of loops considering 20% spare capacity in each loop and each loop shall have a capacity of minimum 300 analog addressable devices, the panel shall work in derade mode in case of CPU failure, four access levels, flash EPROM, 240 volts AC power supply, automatic battery charger, 24 volts sealed lead acid batteries sufficient for 24 hours normal working and 30 mins in alarm condition and designed to meet UL 864, 10th Edition - 1 Loop control panel complete all as specified and directed.
Supply, installation, testing and commissioning of Intelligent Analogue Addressable Optical Beam Detector complete with accessories as per specifications all as specified and directed.
Supply and fix Addressable Manual Call Point (Break Glass Type) having an LED which shall blink in normal state and get steady on activation to monitor the heath status of the device complete all as specified and directed.
Supply and fix Sounder cum Strobe rated at 80 dBA @ 3m for audible annunciation and 115cd flashing at 1 Hz for visual indication, UL Listed complete all as specified and directed.
Supply, installation, testing and commissioning of Addressable Control Module for Sounders/ Strobes/ Sounder cum Strobes complete all as specified and directed.
Supply, installation, testing and commissioning of 2 Core x 1.5 Sq.mm FRLS Armoured Cable drawn through and including rigid steel ERW conduit (stove enameled) heavy duty of dia not less than 20mm as per IS 9537 Part I and including all necessary flame proof, weather proof conduit accessories and fittings complete all as specified and directed.
Supply only ABC type fire extinguisher (IS:15683) of 9 Kg capacity complete all as specified and directed.
Supply only mechanical foam type fire extinguisher of 9 Ltrs capacity complete all as specified and directed.
Supply only wheeled dry powder extinguisher (IS:16018) of 25 kg capacity complete all as specified and directed.
SEWAGE DISPOSAL
Supply , laying and testing of 150mm internal diameter of double wall corrugated (DWC) high density polythylene pipes (HDPE) and stiffness classes - 8 (SN-8) with ISI marked (with CML no) with and including all fittings & jointing material for sewage line and laid in trenches as specified in IS 16098-2013 Part 2 complete all as specified and as directed. Note : Bedding of pipe shall not be provide in normal condition and construction methods shall be strictly complied a per clause no A-4 of Annex 'A' of IS 16098 Part II
INTERNAL WATER SUPPLY
Supply and fixing 15mm dia two way bib tap cast copper alloy chromium plated fancy type with crutch or butterfly handle, screwed down, screwed for iron pipe or brass ferrule complete all as specified and as directed.
NOTE : Amount of credit of Rs. 17750.00 for retrieved materials is mentioned in schedule of credit on Srl Page No. 72(R) of tender documents in pdf form which will be deducted offline while acceptance of tender.
United Sales Corporation (BID ID -3391261)
NSC Projects Pvt. Ltd. (BID ID -3389369)
Vijay Construction Co (BID ID -3384176)
Parth Infrastructure Pvt. Ltd. (BID ID -3372552)
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Tenderdocument.rar
Tender Documents • 0.80 MB
Tenderdocument_2.rar
Tender Documents • 12.45 MB
Tenderdocument_3.rar
Tender Documents • 17.12 MB
BOQ.xls
BOQ • 4.19 MB
Download all tender documents and submit your bid