| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹8.9 LAccepted-AOC | L1 | Accepted-AOC Lowest bidder | |
| 2 | L2₹9.3 L+₹9,056 (0.99%)Rejected-AOC | L2 | Rejected-AOC Second lowest | |
| 3 | Rejected-Technical | - | Rejected-Technical due to slow prog and No remarks in HQ CEPZ WLR |
Tender Value
₹10.8 L
EMD Value
₹21,540
Closing Date
29 Aug 2020, 6:00 pmClosed
GE Palampur
Holta Camp Palampur Kangra (H.P)
SPECIAL REPAIR TO TOILET BLOCK NO P 37 OF 39 MTN DIV PRO UNIT AND CERTAIN SANCTIONED WORKS AT PALAMPUR MIL STN
2020_MES_361345_2
GEP-06(Token)/2020-21
Open Tender
Civil Works
Item Rate
180 days
Palampur
As per tender documents
8 documents required · 8 mandatory
₹500
Yes
GE Palampur
₹21,540
Yes
5 Oct 2020
17 Aug 2020
31 Aug 2020
17 Aug 2020
29 Aug 2020
17 Aug 2020
Amount
SCHEDULE 'A' PART-I:- Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises complete all as specified and directed.
Taking down shutters of any description exc 1 sq.m and n exc 2 sq.m each complete all as specified.
Demolition of cement concrete (unreinforced) in ground floors and pavings n exc 15cm thickness (below or above ground level), complete all as specified and directed.
Taking down cement plaster including wall tiles on brick work or stone walls, etc including raking out joints, hacking for key, scrubbing down with water, etc. complete all as specified and directed.
Taking up or down old 15mm bore steel tubing fixed to wall and ceiling or laid in floor,with all fittings and fixtures and short lengths including cleaning for refixing, removal to store,complete all as specified and directed.
Taking up or down old 20mm bore steel tubing fixed to wall and ceiling or laid in floor,with all fittings and fixtures and short lengths including cleaning for refixing or removal to store,complete all as specified and directed.
Dismantling of cast iron/ PVC /reinforced concrete drain pipes of any size, jointed in cement mortar and taking out of trenches, if required, complete all as specified and directed.
Dismantling of 100mm cast iron/ PVC /Reinforced concrete drain pipes, jointed in cement mortar and taking out of trenches, if required, complete all as specified and directed.
Dismantling wall and ceiling boards (fibre, pulp, insulation, etc.) or insulation boards/slabs/blankets, any thickness, including cover fillets of any description complete all as specified and directed.
Taking down and refixing old PVC partition (including frame and shutter) /panneling in the same position of any description complete all as specified and directed.
M&L for 25mm thick PCC 1:2:4, type B-O (using 12.5mm graded crused stone aggregate) as in floors finished rough to receive floor finishes, complete all as specified and directed.
M&L for Non skid ceremic coloured tiles 7 to 8mm thick (square/rectangular) area of each tile exceeding 0.06 sqm but not exceeding 0.11 sqm in floors etc set and jointed in neat cement slurry and pointed in white or coloured cement to match and including over 15 mm thick screed bed or bedding layer in cement mortar 1:4 complete all as specified and directed.
M&L for glazed ceramic coloured tiles 300mm x 200 mm x 7mm thick as in vertical surfaces such as skirting, dado etc set and jointed in neat cement slurry pointed in white or coloured cement to match over and including 15mm thick rendering in cement mortar 1:4 to receive tiles, complete all as specified and directed.
M&L for 15mm thick rendering on fair faces of brick or stone work surface in CM 1:6 finished the surface even and smooth without using extra cement on internal wall surface, complete all as specified and directed.
Rendering 15mm thick in cement mortar 1:4 mixed with water proofing admixture on fair faces of brick work or concrete surfaces finished the surface even and smooth without using extra cement, complete all as specified and directed. Note :Water proofing admixture to be measured & paid for separately.
S&F in repairs for Gl frame work for seamless ceiling comprising of Gl perimeter channnel 0.55 mm thick with two unequal flanges of 20 and 30 mm and web of 27mm fixed to surrounding wall using nylon sleeves and screws at 450mm centre to centre/intermediate channel 0.9mm thick having two equal flanges of 15mm each and web of 45mm suspended from soffit at approx 900mm centre to centre with Gl cleat and steel expansion fasteners with and including ceiling section (not exc 1.2m length) of 0.55 mm thickness having kurled web of 50mm and flange of 26mm each with lips of 10.5 mm fixed to the intermediate channel with connecting clips across the intermediate channel at 457mm centre to centre including gypsum board 12mm thick of any description complete all as specified and directed.
Preparing of newly plastered wall surface and applying three coats of white wash on newly plastered surfaces with a coat of putty complete all as specified and directed.
Preparing of newly plastered surface and applying two coat exterior emulsion paint with primer on newly plastered surfaces,complete all as specified and directed.
M&L for preperation of old steel surfaces and applying two coats of synthetic enamel complete all as specified and directed.
Preperation of old plastered/unplastered ceiling surfaces including brooming down or steel wire brushing, scraping down smoke soot, moulds, moss and efflorescent salts and trading oil and greasy and applying one coat of white wash complete all as specified and directed.
Preparation of old plasteres/unplastered wall surface including brooming down or steel wire brushing, scraping down smoke soot, moulds, moss and efflorescent salts and trading oil and greasy spots etc and applying one coat of exterior emulsion paint from 3m to 15m height, complete all as specified and directed.
S&F for 4mm Sheet glass, ordinary quality and glazing with oil putty in square n exc 0.5 sq.m in each pane complete all as specified and directed.
S&F for pillar tap, cast copper alloy, with capstan head, chromium plated screwed down high pressure, with or without lettered 'Hot' or 'Cold' with long screwed shanks and fly nuts screwed for iron pipe 15mm bore (fixed in repair), complete all as specified and directed.
S&F in repairs for Viterous china, wash hand basin, oval type countersunk 190mm x 550mm x 430mm including brass CP waste coupling 32mm dia with long screwed shank and fly nuts, PVC, medium grade 32 mm dia waste pipe, chain and plug, porcelain stopper , PVC connection 15mm dia, 450mm long with brass CP nuts and washers at both ends (fixed in repair),complete all as specified and directed.
S&F in repairs vitreous china bowl urinal flat back, size of 465 x 355 x 265 mm white (minimum), with grating and union for discharge pipe (including flush pipe and waste pipe) complete all as specified and directed.
S&F for CP two way stop/angle cock 15mm cast copper alloy screwed down high pressure, screwed both ends for iron pipes or for unions, 15mm bore fancy type and fixed in repairs complete all as specified and directed.
S&F for PVC connections 15mm size with PTMT nuts of length 600mm complete all as specified and directed.
S&F for 20mm dia gun-metal, globe or gate valves, with iron wheel head, screwed both end for iron pipe and fixed complete all as specified and directed.
S&F steel water tubing 15mm bore medium grade galvanised with all fittings and fixtures and short lengths, fixed to wall and ceiling or laid in floor,complete all as specified and directed.
All as per the description of serial item No. 29 above but except GI tubing, complete all as specified and directed.
S&F for steel tubes, 20mm boremedium grade galvanised with all fittings and fixtures and short lengths, fixed to wall and ceiling or laid in floor, complete all as specified and directed.
All as per the description of serial item No 31 above but except GI tubing, complete all as specified and directed.
S&F in repairing of vitreous china squatting pan, 'orissa' pattern, size 580 x 440 mm white , with integral foot rests (excluding flushing cistern and flushing pipe), including connection to trap and to flushing pipe, anti-syphonage pipe, etc, complete including making good to floor complete all as specified and directed.
S&F in repairs of vitreous china coloured wash down water closet pan (Pedestal Pattern), (fixed in repair), including connection to flush pipe, 'P' or 'S' trap, with fixing bolts PVC seat cover with chromium plated mild steel hinges device (excluding flushing cistern and flush pipe),complete all as specified and directed.
S&F for 10 litres capacity PVC, low level, valveless, syphonic action type flushing cistern, inlet ball valve, float valve, handle and fixing arrangement including 32mm dia. PVC flushing pipe, PVC connection 15mm size with PTMT nuts of length 450mm and with CP brass coupling & PVC washer at both ends,complete all as specified and directed.
S&F for 100mm size butt hinges medium weight, cold rolled MS and fixed complete all as specified and directed.
S&F for 75mm size butt hinges medium weight, cold rolled MS and fixed complete all as specified and directed.
S&F in repairs for solid PVC door frame of size 50 mm x 47 mm made out of 15mm plain colour PVC sheet reinforced with M.S. square tube, suppling & fixing in opening as per spacification & drawing shown in SSR Part-II, complete all as specified and directed.
S&F in repairs for 5mm thick plain colour PVC sheet in strips & channel feathered at the edges for fixing on Solid PVC Wall Lining, Insulated PVC Wall Lining, and Solid PVC Partitions inclusive of solvent Cement and fixing at site complete all as specified and directed.
S&F factory made solid panel PVC door shutter 30mm thick (style) consisting of frame made out of MS tubes for top and bottom rails. MS frame shall be covered with heat moulded plain colour PVC ' C' channel having a PVC sheet strip of 20mm width struck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail and bottom rail on either side and as gap insert for top rails and bottom rail, panelling of plain colour PVC sheet to be fitted in the MS frame welded/sealed to in stiles & rails with suitable PVC sheet beading and joinned together with solvent cement supplying & fixing in frames at site as per specification and drawing shown in SSR Part -II,complete all as specified and directed.
S&F for PVC Waste water pipe 32mm or 40mm dia, 750mm long for WHB/Sink complete all as specified and directed.
S&F for bib cock CP for 15mm bore fancy type, cast copper alloy, screwed down, screwed for iron pipe or brass ferrule and fixed in repairs complete all as specified and directed.
S&F for towel rail 450mm long of PTMT fixed with and including chromium plated brass screws and wooden/plastic cleats (Minimum weight 170 gms), complete all as specified and directed.
S&F in repairs for PVC (SWR) vent cowl 75mm dia. laid and jointed, complete all as specified and directed.
S&F in repairs for PVC (SWR) vent cowl 110mm dia. laid and jointed, complete all as specified and directed.
S&F in repairs for PVC (SWR) pipe single socketed, in any length with rubber ring joints, laid in tenches or in floors as in repair, 75mm bore, complete all as specified and directed.
S&F in repairs for PVC (SWR) junction, (single T) equal or unequal of 75mm bore, complete all as specified and directed.
S&F in repairs for PVC (SWR) 75mm bore, floor trap with grating including jointing with solvent cement, fixed in repair, complete all as specified and directed.
S&F in repairs for PVC (SWR) bends of 75mm bore pipe, complete all as specified and directed.
S&F in repairs for PVC (SWR) junction, (single T) equal or unequal of 110mm bore, complete all as specified and directed.
S&F in repairs for PVC (SWR) pipe single socketed in any length with rubber ring joints, fixed to wall, ceiling, floors etc, 110mm bore of pipe (fixed in repair), complete all as specified and directed.
S&F in repairs for bands, straps, supports or stays for rainwater, ventilating pipes, including bolts, if required: hooks (stay), heavy, for large gates; hook and pintle hinges: large hasps and staples; chains; hand made sliding bolts; clamps; hold fasts; wall ties; hooks for hanging fans; plain angle cleats for securing purlins to wood trusses or rafters; knee piece inserts; two way and three way straps, plate washers and similar small articles conforming to Fe-290 Gde-E-165 complete al as specified.
S&F in repairs for PVC (SWR) bends of any radius for 110mm bore pipe (fixed in repair), complete all as specified and directed.
S&F in repairs for PVC (SWR) 110mm bore, floor trap with grating including jointing with solvent cement, fixed in repair, complete all as specified and directed.
Supply only liquid water proofing compound, complete all as specified and directed.
Surface excavation n.exc (not exceeding) 30cm deep and averaging 15cm deep and getting out in any type of soil complete all as specified and directed.
Hard core of broken stone or boulders of guage n. exc 63mm, deposited, spread and levelled in layers n. exc 15cm thick, watered and rammed to a true surface, complete all as specified and directed.
Plain cement concrete 1:4:8, type D-2 (using 40mm graded crushed stone aggregates) as in foundation filling and mass concrete, complete all as specified and directed.
Plain cement concrete 100mm thick 1:2:4 (Nominal Mix) type B-2 (using 40mm graded crushed stone aggregates) as in hard standing, finishing the surfaces even and fair, complete all as specified and directed
Forming Contraction (Dummy) joints 65mm deep x 10mm wide and used to edges primed with primer suitable for sealing compound and filled with sealing compound Grade 'A', complete all as specified and directed.
Removing excavated soil to a distance not exceeding 50m depositing where directed at a level not exceeding 1.50m above the starting point, complete all as specified and directed.
Plain cement concrete 1:3:6, type C-2 (using 40mm graded crushed stone aggregates) as in foundation filling and mass concrete, complete all as specified and directed.
Demolition of brick work or stone /boulder masonry, built in cement mortar, including all quoins, arches, pillars etc but excluding ashlar facing, dressed stone work and precast concrete articles etc, complete all as specified and directed.
Demolition of cement concrete (reinforced) of any description and in any position not otherwise specifically provided for, complete all as specified and directed.
Excavation in trenches, not exceeding 1.5m wide and not exc 1.5m in depth for foundation, and getting out in any type of soil, complete all as specified and as directed .
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25cm thick in any type of soil, complete all as specified and as directed.
Plain cement concrete bed to drain pipes including packing under and haunching against the sides of pipe after they are laid and tested in plain cement concrete M-10 (Nominal mix) type C-2 (using 40mm graded crushed stone aggregates) for 150mm bore pipe, complete all as specified and directed.
150 mm dia reinforced concrete pipes, class NP3, laid and jointed complete with collars all as specified and directed.
Brick work with sub class 'B' bricks, straight or curved on plan on exceeding 6m mean radius, using old size brick, built in cement mortar 1:4, complete all as specified and directed.
Walling of random rubble stone masonry uncoursed, with best quality locally available harder stones such as granite, trap, basalt stone etc, well bonded, bedded and solidly hearted , built in cement mortar 1:6, complete all as specified and directed.
Raised pointing to random or polygoned rubble walling, uncoursed, or brought upto courses in cement mortar 1:3, complete all as specified and as directed.
Plain cement concrete, M-15 (Nominal mix), type B-1 (using 20mm graded crushed stone aggregates) as in cills, coping, apex stone, bed plates and lintel upto 1.5m clear span etc including weathering slightly rounded or chamfered angles and throating as directed including necessary form work, complete all as specified and directed. (Note- Reinforcement shall be measured and paid separately under relevent items).
TMT bars 6mm to 8mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia,complete all as specified and directed.
S&F bands, straps, supports or stays for rainwater, ventilating pipes, including bolts, if required: hooks (stay), heavy, for large gates; hook and pintle hinges: large hasps and taples; chains; hand made sliding bolts; clamps; hold fasts; wall ties; hooks for hanging fans; plain angle cleats for securing purlins to wood trusses or rafters; knee piece inserts; two way and three way straps, plate washers and similar small articles conforming to Fe-290 Gde-E-165 including two coats of tar or coal tar black paint complete all as specified and directed.
Precast reinforced cement concrete, M-15 (Nominal mix), Type B-1 (using 20mm graded crushed stone aggregates) as in cover slab, manhole cover, shelves and similar articles with plain face, set and jointed in cement mortar 1:4, complete all as specified and directed. (Note : Reinforcement shall be measured and paid separately)
S& F hand rails, half round or other stock section or core for wooden hand-rail straight portion, drilled and countersunk for balusters running bars, for doors, balusters, nosing to steps including embeding in concrete and screwing etc. wind ties for roof including securing bolts; posts and struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire, etc.; flat iron fillets (for securing wire mesh etc.) including all necessary drilling, bolting or riveting, etc., and similar work conforming to Fe-290 Gde E-165
Preparation of new steel surfaces of any description not otherwise described, over 10cm width or girth and applying two coats of synthetic enamel paint over a coat of red oxide zinc chrome primer, complete all as all as specified and directed.
Cutting holes in stone walls built in cement mortar or in cement lime mortar exc half brick but n. exc one brick for inserting holdfasts and making good dismantled portion in cement mortar 1:3 or cement concrete 1:2:4 Type B-1 as required complete all as all as specified and directed.
SCHEDULE 'A' PART-II:- Point wiring with 2.5 Sqmm PVC (FRLS) insulated unsheathed multi stranded copper conductor cable 1100 volts grade single core conforming to IS-694-1990 and including one run of continous earth wire to common earth and connected to earth with 2.5 Sqmm PVC (FRLS) insulated unsheathed multi stranded copper conductor cable draw in & incl PVC surface casing 'N' capping double lock type to be fixed with the help of rawal plugs & screws incl necessary fittings & fixture and to be turminated in sunk cast iron/pressed steel/PVC terminal boxes for mounting switches, sockets, regulators etc with 3 mm thick plastic laminated sheet cover of adequate size for one light point/fan point controlled by one switch and making good disturbed surfaces with CM (1:4) to match with the existing surface complete all as specified and directed .
Switch piano flush button, 15 Amps, 240 volts, single pole one way complete all as specified and directed.
Socket outlet 2 in 1, 5 Pin 15 Amps flush type complete all as specified and directed .
MCB SP, 6 to 32 Amps, 240 Volts 10 KA, 'C' series complete all as specified and directed.
Supply and installation of electric storage water heater (vertical type geyser five star rating, 25 ltr capacity 240 V, AC single phase having stainless steel inner tank complete in all respect including air release valve etc incl grouting nut bolt of suitable size and lenght minimum 4" long as per site requirement and making necessary inlet/outlet water connection including suitable PVC pipe suitable for hot and cold water and making electrical with plug top 15 amps and water connection and making good disturbed surface of walls to match with existing surface complete all as specified and directed.
15mm bore bib tap, chromium plated cast copper alloy with crutch or butterfly handle, screwed down for high pressure screwed for iron pipe or brass ferrule (fixed in repair),complete all as specified and directed.
15mm bore stop valves, cast copper alloy, screwed down, high pressure, fancy type, chromium plated with long shank and cup (concealed type) screwed both ends for iron pipe or union (fixed in repair), complete all as specified and directed.
Steel water tubing, 15mm bore dia, galvanised, "medium grade" with all fittings and fixtures and short lengths, fixed to wall and ceiling or laid in floor including cutting chases for concealed work etc, complete all as specified and directed.
M & L for cutting of existing pipe GI pipe line of size 15 mm size (02 cuts) in position for making branch connection 15mm dia for inserting of Tee complete including Tee of required size and other fitting such as sockets, nipples, unions etc complete including making threads in position for both side as per site requirement and making good disturbed surface of walls to match with existing surface complete all as specified and directed.
m t construction co
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .