Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹11.4 LAccepted-AOC DHALESWAR JAIL ASHRAM ROAD AGARTALA TRIPURA W | DHALAI | TRIPURA | 799204 | L1 | Accepted-AOC Accepted by committee |
Tender Value
₹11.0 L
EMD Value
₹22,061
Closing Date
15 Feb 2024, 5:30 pmClosed
DGM
O/o the DGM,ED-II,Bardowali
Extension of HT LT line including 3X63 KVA Sub Station for providing service connection at Shital Das Para Champamura Gakulnagar Madhya Para Sabar Para Harishnagar GP of Jal Jeevan Mission Har Ghar Jal within the of ESD Sekerkote
2024_POWER_46599_1
DGM/ED-II/2023-24/15
Open Tender
Electrical Works
Item Wise
30 days
Sekerkote
Please refer Tender documents.
8 documents required · 8 mandatory
₹3,540
₹22,061
5 Mar 2024
7 Feb 2024
16 Feb 2024
7 Feb 2024
15 Feb 2024
7 Feb 2024
Amount
(Supply & Erection)
Erection of 9 mtrs length of Steel Tubular POLE at any kind of soil upto a depth of 1/6 th of pole height, including excavation of earth, refilling the pit with soil upto the ground level, ramming and making complete in all respect.
Erection of Stay set direct in earth complete with 19mm x 1800 mm long stay rod, anchor plate of size 300 x 300 x 8 mm ,thimble, turn buckle, 7/3.15 mm dia G.I Standed stay wire and stain insulator etc. with Supply of M.S.Clamp,Nuts & Bolts etc. as required. and making complete in all respect.
Laying & Stringing of 1KM (Single Conductor) ACSR 6/1/2.59 mm dia 'WEASEL' including hoisting & binding etc. Complete as required.
Laying & strining of 1KM (Single Conductor) , 10/8SWG GI wire including hoisting & binding etc. Complete as required.
Erection of 11KV protective Guarding by GI wire 8 SWG as per technical specification,across road/River/ Telecom line etc. in horizonta formation complete .
Erection of 11KV Pin insulator along with Pin.
Erection of 11KV Single Disc insulator set along with necessary fittings.
Erection of 11KV 200 Amp. GOS unit set of three nos. including necessary connection complete as per technical specification.(Excluding the cost of back clamp,Nuts & Bolts)
Erection of 11KV DOF unit set of three nos. including necessary connection complete as per technical specification.(Excluding the cost of back clamp,Nuts & Bolts)
Erection of 9 KV,5 KA single pole metal oxide gapless type LA , including necessary connection complete as per technical specification.
Erection of M.S.Channel Cross-Arm,0.3 to 1.2 Mtr. Long75 x40 x 40 x 6 mm ( Excluding the cost of Back Clamp, Nuts & Bolts)
Erection of M.S.Channel Cross-Arm,1.3 to 2.8 Mtr. Long75 x40 x 40 x 6 mm ( Excluding the cost of Back Clamp, Nuts & Bolts)
Erection of M.S.Channel Cross-Arm,0.6 to 2.8 Mtr. Long100 x50 x 50 x 6 mm ( Excluding the cost of Back Clamp, Nuts & Bolts)
Erection of M.S.Angle Cross-Arm,1.0 to 2.8 Mtr. Long 65 x65 x 6 mm ( Excluding the cost of Back Clamp, Nuts & Bolts)
Installation / Positioning of 11/0.430 KV,3-Phase 63KVA of Distribution Transformer on Pole with necessary connections & fitting fixing of all allied accessories components as required for making complete in all respect for energizing.
Febrication of Cross-Arms by MS Channel/MS Angle as per specification
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 11 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required.Trench Size: Width-350mm, Hieght-1200mm / Sand (couhioning): Hieght-250mm, Width-350mm/ Protection: Double layer Bricks Upto 120 sq. mm
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 11 KV grade of following size in the existing RCC/ HUME/ METAL pipe as required,Upto 120 sq. mm
Manually digging /drilling horizontally or diagonali direction for road crossing / Water supply line/Telcomunication line/Gas Pipe line etc. including Laying of 64 to 200mm dia GI pipe direct into the earth at a depth of minimum 1100mm below the ground surface with out effecting the existing road including excavation earth for entry pit as per site condition and direction of Engineering In Charge.
Laying and fixing following dia G.I. pipe (medium class) in ground complete with G.I. fittings including trenching (120 cm deepth)and re-filling etc as require
Providing of Pre-cast cement concretecable identification route marker (1 cement: 2 coarse sand : 4 graded stone aggregate 6mm nominal size) reinforced with 1.6 mm dia mild steel wire including centring and shuttering, roughening cleaning, fixing and finishing in cement mortar 1:3(1cement : 3 fine sand) etc. complete, excluding the plastering of jambs, sills and soffits as per design, drawing and specification of TSECL. The marker shall be embossed "DANGERS: TSECL, ELECTRIC POWER CABLE" with Black colour letter(both side). The visible part shall be painted with Yellow colour japan paint. (1 cement: 2 coarse sand : 4 graded stone aggregate 6mm nominal size) reinforced with 1.6 mm dia mild steel wire including centring and shuttering, roughening cleaning, fixing and finishing in cement mortar 1:3(1cement : 3 fine sand) etc. complete, excluding the plastering of jambs, sills and soffits.
Providing Three Phase Service Connection with laying PVC cable from nearby Electrical pole to Premises upto 35mtr. in length supported by G.I.Wire,Reel Insulator i/c fitting fixing of Energy Meter as required .
Grouting of steel tubuler poles /stay set with CC of ratio 1:2:4(1 cement : 2 river sand : 4 Jhama brick aggregate of 20 mm nominal size)i/c supply of cement,sandand brick aggregate20 mm nominal size complete with excavation, refilling of earth ,ramming alonf with centeringand shutteringaas required @ 0.273 CUM per Steel tubuler pole & & 0.119 Cum/stay sets per TSECL specification,9 Mtr. long S.T Pole(0.273X15=4.095 CUM)
Earthing with G.I pipe 2.5mtr. Long and 40mm dia including excavation, refilling with alternate layer of salt & Charcoal as per drawing including supply of G.I.Pipe, Salt & Charcoal, GI wire, nuts &bolts, etc. as required.
Carriage of 9.0mtrs length of Steel Tubular Poles by Mechanical Transport from the Electrical Sub-Divisional Site Store to working site Vis-a-vis, including loading, unloading and stacking as required b) Beyond 25 KM upto the lead of 50KM,ii) Beyond 8 (eight) poles
Carrying of the store materials from Electrical Store Sub-Division, AD Nagar, Agartala to ESD- Sekerkote storeyard by mechanical transport i/c loading unloading & stacking etc. Upto the lead of 25 KM
Carriage of materials such as Cable,AAC, AAAC, ACSR, G.I.Wire,Cross-Arm,Stay Set,Insulators etc., by Mechanical Transport from the Electrical Sub-Divisional Site Store to working site Vis-a-vis, including loading, unloading and stacking as required, upto the lead of 25KM & 50KM. Upto the lead range 25KM
Carriage of G.O.S, D.O.F,L.A,etc., by Mechanical Transport from the Electrical Sub-Divisional Site Store to working site Vis-a-vis, including loading, unloading and stacking as required,Upto the lead range 25KM
Carriage of 11/0.430, 3-Phase 63KVA by Mechanical Transport from the Site /Store/Worshop to working site Vis-a-vis including loading, unloading and placing on base, as required,Beyond 25 KM upto the lead of 50KM
Cartage of Power Cable from TSECL store or Stack sites by Mechanical Transport including loading, unloding and stacking/positioning by mannual mode up to work site: (Cost including cable drum Lifting Jack, removing of cable from Drum, coiling of removed cable etc.)Weight of 3-Core, 6.35/11kV XLPE Cable, Flat Strip (Kg/Km):35sqmm(2350Kg),50sqmm(2700Kg),70sqmm(3100Kg), 95sqmm(3700Kg),120sqmm(4200Kg),35sqmm to 120sqmm
Supply of 11 KV XLPE Cable,3CX70 Sqmm.
Supply of 95 Sqmm Bimetalic Lugs
Supply of Wooden Plank(24"X10'X1.5"size)
Supply of Polythene Pipe 1/2" dia
Supply of Fabricated MS Bracket Clamp
Supply of Fabricated MS Stay Clamp
Supply of MS Nuts & Bolts ( assorted size)
Supply of Outdoor heat shrinkable cable jointing kit with lugs for 11 KV grade XLPE cable for 3 core 70 sq. mm.
Supply of HDPE Pipe 90 mm dia
Supply of G.I.Pipe,80 mm dia(Medium Class)
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .