| 1 | L1₹1.5 LAccepted-AOC | L1 | Accepted-AOC Admitted | |
| 2 | L2₹1.6 L+₹11,189 (7.48%)Rejected-AOC | L2 | Rejected-AOC Rejected | |
| 3 | L3₹1.8 L+₹30,308 (20.3%)Rejected-AOC DOOR NO 7 2 30 3 OPP APSEB SUB STATION OLD GAJUWAKA MARRIPALEM VISAKHAPATNAM 530026 | VISAKHAPATANAM | ANDHRA PRADESH | 530026 | L3 | Rejected-AOC Rejected | |
| 4 | L4₹1.9 L+₹38,235 (25.6%)Rejected-AOC MIG 330 MADHAVADHARA VUDA COLONY VISAKHAPATNAM 530 018 | VISAKHAPATANAM | ANDHRA PRADESH | 530018 | L4 | Rejected-AOC Rejected | |
| 5 | L5₹1.9 L+₹40,200 (26.9%)Rejected-AOC | L5 | Rejected-AOC Rejected |
| Sl No | Description | Qty | Unit | Sigma6 L5 | M/s.DSRK CONSTRUCTIONS L4 | ANJALI ENTERPRISES L7 | NAMMI KARTHIK DEEPU L8 | newton electro technics L3 | M/S Jayalakshmi Constructions L9 | SRASHA MARINE SERVICES L1 | SRI SIDDHI VINAYAKA ENTERPRISES L2 | ANAND ENTERPRISES AND ENGINEERS L6 |
|---|---|---|---|---|---|---|---|---|---|---|---|---|
| .01SCHEDULE 'A' PART-I: E/M WORKS | ||||||||||||
| 1.00 | Supply, install, testing and commissioning of BEE 5 star rated hi-wall split units indoor/outdoor with cordless remote control unit and with in built filter for better indoor air quality with latest inverter technology having eco friendly refrigerent gas, copper condenser coil,of capacity 2.0 TR all as specified and directed by the Enginer-in-Charge. [Make: BLUE STAR / HITACHI / DAIKIN / CARRIER/LG]
Note : 1.The rate consider deemed to include of bracket for fixing of indoor and outdoor unit in wall of any height as directed by Engr-in charge.
2. The copper tube of suitable size (for each ACs), Drain pipe, cables are included in quoted rate. 3. Provision of passing of indoor/outdoor pipe from wall / core cutting in any type of wall are included with quoted rate. | 2 | EACH | 68,000 ₹1,36,000 | 66,000 ₹1,32,000 | 85,000 ₹1,70,000 | 81,000 ₹1,62,000 | 66,500 ₹1,33,000 | 92,349 ₹1,84,698 | 61,500 ₹1,23,000 Lowest | 65,007 ₹1,30,014 | 78,500 ₹1,57,000 |
| 2.00 | S & F in repairs moduler sheet metal enclosure with single pole and neutral enclosure with a two pin and earth plug and socket complete with one MCB, SP, 20 Amps, 240 volts, 10 KA complete suitable for AC all as specified and directed. | 2 | Each | 1,700 ₹3,400 | 800 ₹1,600 Lowest | 1,200 ₹2,400 | 3,000 ₹6,000 | 1,344 ₹2,688 | 1,000 ₹2,000 | 1,200 ₹2,400 | 972 ₹1,944 | 1,150 ₹2,300 |
| 3.00 | Supply and fix Voltage stabilizer for automatic operation, single phase naturally air cooled indoor type & designed for input variation between 170 V to 250 V with output voltage stabilized at 230 V with accuracy of ± 2.5% and of capacity 5KVA | 2 | EACH | 3,400 ₹6,800 | 8,000 ₹16,000 | 3,500 ₹7,000 | 7,500 ₹15,000 | 3,468 ₹6,936 | 4,200 ₹8,400 | 3,000 ₹6,000 Lowest | 3,006 ₹6,012 | 3,200 ₹6,400 |
| 4.00 | M&L for sub main wiring with four run of 10.0 Sq. mm PVC un-sheathed, copper conductor cable, 1100 Volt, and one run of copper earth wire 10.0 Sq mm drawn through PVC concealed/surface conduict of 40 mm dia, including taking down unsv sub main wiring of any type, complete all as specified. Note: Copper conductor 05 run along with PVC concealed conduict shall be measured as one length & Cutting of chases/walls and making good the disturbed surface are included in the rate. | 10 | RM | 850 ₹8,500 | 450 ₹4,500 Lowest | 450 ₹4,500 Lowest | 900 ₹9,000 | 1,032 ₹10,320 | 700 ₹7,000 | 600 ₹6,000 | 792 ₹7,920 | 850 ₹8,500 |
| 5.00 | M & L for sub main wiring with 2 runs of single core 1100 volts grade, PVC insulated, unsheathed, FRLS copper conductor cable of size 4.0 Sqmm, drawn through and including surface PVC conduit of size 20mm dia including conduit accessories including provision of 1 run of 4.0 Sqmm PVC insulated, unsheathed, FRLS copper conductor cable as earth continuity conductor complete all as specified and directed.
[NOTE: 3 runs of 4.0 Sqmm cable and 1 run of PVC conduit shall be measured as one unit length.] | 10 | RM | 800 ₹8,000 | 250 ₹2,500 | 250 ₹2,500 | 600 ₹6,000 | 858 ₹8,580 | 200 ₹2,000 | 120 ₹1,200 Lowest | 198 ₹1,980 | 410 ₹4,100 |
| 6.00 | Supply and fixing in replacement of Factory made sheet metal enclosure for DBs double door (Fixed flush to the wall), TPN, 415 volt, 4 Way, IP-42 protection with 200 Amp rated bus bar and 1.5 Sq. mm copper PVC sheathed cable for earth continuity and suitable for having MCB’s , complete all as specified. | 1 | Each | 5,300 ₹5,300 | 6,000 ₹6,000 | 3,200 ₹3,200 | 6,000 ₹6,000 | 3,060 ₹3,060 | 4,500 ₹4,500 | 2,500 ₹2,500 | 2,700 ₹2,700 | 1,850 ₹1,850 Lowest |
| 7.00 | Supply and fixing of MCB 6 to 32Amp, 240 Volt, SP, breaking capacity 10 KA 'C' series, complete all as specified | 2 | Each | 530 ₹1,060 | 4,500 ₹9,000 | 280 ₹560 | 510 ₹1,020 | 240 ₹480 | 300 ₹600 | 150 ₹300 Lowest | 153 ₹306 | 210 ₹420 |
| 8.00 | Supply and fixing MCB TPN 63 Amps,10KA,C curve all as specified and directed | 1 | Each | 3,000 ₹3,000 | 5,700 ₹5,700 | 650 ₹650 Lowest | 1,800 ₹1,800 | 2,351 ₹2,351 | 2,000 ₹2,000 | 1,800 ₹1,800 | 2,025 ₹2,025 | 1,800 ₹1,800 |
| 9.00 | Earthing complete with Galvanised Steel Earth Plate Electrode 600 x 600 x 6 mm thick burried directly in ground (Earth Pit not less than 1.5 m below normal ground level connected to galvanised earth lead wire 4.0 mm as earth lead and GI pipe 40 mm, Medium Grade for earthing lead protection to the extent of maximum 7.5m, Earth Plate Electrode surrounded by 150mm thick packed layers of Charcoal and Common Salt filled in alternate layers, connected to the Plate by means of GI Bolts & Nuts complete all as per Electrical Plate No 3 of SSR Part - I, connected to panel/DB including testing on completion including main earthing, Charcoal, Common Salt, PCC (1:2:4, Type B1) Pit with RCC 1:2:4, Type B1 Cover, 50mm thick with 6 Nos, 8 mm dia TMT bars in both ways, MS Funnels with 20 mm bore, medium grade GI watering Pipe, Wire Mesh, Earth Work excavation, return filling, removal of surplus soil etc., and disconnecting and taking down existing Earthing of any description complete all as specified and directed. | 1 | Each | 16,800 ₹16,800 | 10,000 ₹10,000 | 6,500 ₹6,500 | 8,100 ₹8,100 | 11,760 ₹11,760 | 9,000 ₹9,000 | 6,000 ₹6,000 Lowest | 6,507 ₹6,507 | 6,200 ₹6,200 |
Tender Value
₹2.5 L
EMD Value
₹5,000
Closing Date
3 Dec 2025, 6:00 pmClosed
Garrison Engineer Naval Depot
Garrison Engineer Naval Depot Industrial Estate Post 104 Area Visakhapatnam 530007
PROVISION OF TWO IN NOS OF AIR CONDITIONERS FOR NCN SERVER ROOM AT CTW VISAKHAPATNAM
2025_MES_739805_1
8547/GEND/E8
Open Tender
Electrical and Maintenance Works
Item Rate
90 days
Visakhapatnam
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
GE ND VISAKHAPATNAM
₹5,000
Yes
8 Jan 2026
14 Nov 2025
5 Dec 2025
14 Nov 2025
3 Dec 2025
28 Nov 2025
Amount
SCHEDULE 'A' PART-I: E/M WORKS
Supply, install, testing and commissioning of BEE 5 star rated hi-wall split units indoor/outdoor with cordless remote control unit and with in built filter for better indoor air quality with latest inverter technology having eco friendly refrigerent gas, copper condenser coil,of capacity 2.0 TR all as specified and directed by the Enginer-in-Charge. [Make: BLUE STAR / HITACHI / DAIKIN / CARRIER/LG] Note : 1.The rate consider deemed to include of bracket for fixing of indoor and outdoor unit in wall of any height as directed by Engr-in charge. 2. The copper tube of suitable size (for each ACs), Drain pipe, cables are included in quoted rate. 3. Provision of passing of indoor/outdoor pipe from wall / core cutting in any type of wall are included with quoted rate.
S & F in repairs moduler sheet metal enclosure with single pole and neutral enclosure with a two pin and earth plug and socket complete with one MCB, SP, 20 Amps, 240 volts, 10 KA complete suitable for AC all as specified and directed.
Supply and fix Voltage stabilizer for automatic operation, single phase naturally air cooled indoor type & designed for input variation between 170 V to 250 V with output voltage stabilized at 230 V with accuracy of ± 2.5% and of capacity 5KVA
M&L for sub main wiring with four run of 10.0 Sq. mm PVC un-sheathed, copper conductor cable, 1100 Volt, and one run of copper earth wire 10.0 Sq mm drawn through PVC concealed/surface conduict of 40 mm dia, including taking down unsv sub main wiring of any type, complete all as specified. Note: Copper conductor 05 run along with PVC concealed conduict shall be measured as one length & Cutting of chases/walls and making good the disturbed surface are included in the rate.
M & L for sub main wiring with 2 runs of single core 1100 volts grade, PVC insulated, unsheathed, FRLS copper conductor cable of size 4.0 Sqmm, drawn through and including surface PVC conduit of size 20mm dia including conduit accessories including provision of 1 run of 4.0 Sqmm PVC insulated, unsheathed, FRLS copper conductor cable as earth continuity conductor complete all as specified and directed. [NOTE: 3 runs of 4.0 Sqmm cable and 1 run of PVC conduit shall be measured as one unit length.]
Supply and fixing in replacement of Factory made sheet metal enclosure for DBs double door (Fixed flush to the wall), TPN, 415 volt, 4 Way, IP-42 protection with 200 Amp rated bus bar and 1.5 Sq. mm copper PVC sheathed cable for earth continuity and suitable for having MCB’s , complete all as specified.
Supply and fixing of MCB 6 to 32Amp, 240 Volt, SP, breaking capacity 10 KA 'C' series, complete all as specified
Supply and fixing MCB TPN 63 Amps,10KA,C curve all as specified and directed
Earthing complete with Galvanised Steel Earth Plate Electrode 600 x 600 x 6 mm thick burried directly in ground (Earth Pit not less than 1.5 m below normal ground level connected to galvanised earth lead wire 4.0 mm as earth lead and GI pipe 40 mm, Medium Grade for earthing lead protection to the extent of maximum 7.5m, Earth Plate Electrode surrounded by 150mm thick packed layers of Charcoal and Common Salt filled in alternate layers, connected to the Plate by means of GI Bolts & Nuts complete all as per Electrical Plate No 3 of SSR Part - I, connected to panel/DB including testing on completion including main earthing, Charcoal, Common Salt, PCC (1:2:4, Type B1) Pit with RCC 1:2:4, Type B1 Cover, 50mm thick with 6 Nos, 8 mm dia TMT bars in both ways, MS Funnels with 20 mm bore, medium grade GI watering Pipe, Wire Mesh, Earth Work excavation, return filling, removal of surplus soil etc., and disconnecting and taking down existing Earthing of any description complete all as specified and directed.
M & L of CPVC Pipe of size 25mm complete including all accessories and fixing in wall and ceiling for connecting the drain pipe of AC to outside Bldg all as specified and directed by Engr-In-Charge..
SRI SIDDHI VINAYAKA ENTERPRISES (BID ID -3488023)
newton electro technics (BID ID -3493913)
M/s.DSRK CONSTRUCTIONS (BID ID -3488215)
Sigma6 (BID ID -3486959)
ANAND ENTERPRISES AND ENGINEERS (BID ID -3488407)
ANJALI ENTERPRISES (BID ID -3488562)
NAMMI KARTHIK DEEPU (BID ID -3488613)
M/S Jayalakshmi Constructions (BID ID -3494271)
stage.html
html • 0.06 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.33 MB
Tender8547.pdf
Tender Documents • 0.93 MB
BOQ_828390.xls
BOQ • 0.34 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .