Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹40.6 CrAccepted-AOC 16 RADHANATH CHOWDHURY ROAD KOLKATA WEST BENGAL 700015 | KOLKATA | WEST BENGAL | 700015 | ₹40.6 Cr | L1 | Accepted-AOC L1 |
Tender Value
₹43.2 Cr
EMD Value
₹86.5 L
Closing Date
28 Jan 2026, 3:00 pmClosed
SENIOR SUPERINTENDING ENGINEER
KHADYASHREE BHAWAN, 1ST FLOOR, 11A MIRZA GHALIB STREET, KOLKATA 700087
Construction of 19,720 MT Food Storage Godown at Dafarpur, in the district of Murshidabad.
2025_WBSWC_979293_1
36(2nd Call) OF 2025-26 OF SE/WBSWC
Open Tender
CIVIL WORKS
730 days
DAFARPUR
PLEASE REFER TENDER DOCUMENTS.
6 documents required · 6 mandatory
₹0
₹86.5 L
6 Mar 2026
24 Dec 2025
30 Jan 2026
26 Dec 2025
28 Jan 2026
30 Dec 2025
Surface Dressing of the ground in any kind of soil including removing vegetation inequalities not exceeding 15 cm depth and disposal of the rubbish within a lead upto 75 m as directed.
Clearing compound premises of shurbs, plants, jungles etc. by cutting and removing as directed (Specific permission of Engineer-in-Charge prior to execution will be necessary). (Payment to be made on area cleared).
Compacting original ground supporting embankment Loosening, Leveling and Compacting original ground supporting embankment to facilitate placement of first layer of embankment, scarified to a depth of 150 mm, mixed with water at OMC and then compacted by rolling so as to achieve minimum dry density as given in Tables 300.1 and 300.2 for embankment construction as per Clause 305.3.4 of Specifications for Road & Bridge Works of MoRT&H (5th Revision).
Earth work in excavation of foundation trenches, in all sorts of soil including removing, spreading or stacking the spoils within a lead of 75 m. as directed. The item includes necessary trimming the sides of trenches, levelling, dressing and ramming the bottom, bailing out water as required complete. (a) Depth of excavation not exceeding 1,500 mm.
b) Depth of excavation for additional depth beyond 1500mm upto 3000mm but not requiring shoring.
Providing Bored Cast-in-situ_______ grade R.C.C. pile in position as per specifications in all kinds of soil including cost of boring using drilling mud tostabilize the bore and flushing the bore of excess mud with freshly prepared drilling fluid by using pump sprior to placing concrete by tremie pipe in one continuous operation and including the cost of all material sand labour for placing of concrete and also including the cost of mobilization and hire charges of all equipment necessary for boring, welding of reinforcement cage as necessary and lowering of reinforcement cage, preparation and placing of concrete, including the cost of concrete but excluding the cost of reinforcement and labour for bending bindin getc. complete as per Drawing and Technical Specification sand removal of excavated earth with all lift sand lead upto 1000 m. Work to be executed as per IS: 2911 (Part II Sec 2). (b) Using tripod, winches i) Pile diameter - 500 mm. (b) For 500mm Pile
Removal of mud/sludge/slurry/ liquid earth obtained during piling work from the working site and disposal of the same beyond theKMC/Municipal or any suitable area with conformity of Municipal Corporation Rules using tanker including loading and unloading the same with pump, clearing the site complete in all respect as per direction of the Engineer-in-charge. (b) For 500mm Pile
Earth work in filling in foundation trenches or plinth with good earth, in layers not exceeding 150 mm. including watering and ramming etc. layer by layer complete. -With earth obtained from excavation of foundation. (Payment to be made on the basis of measurement of finished quantity of work). a) With earth obtained from excavation
Construction of Embankment with Material Obtained from Borrow Pits Construction of embankment with approved material obtained from borrow pits with a lift upto 1.5 m, transporting to site, spreading, grading to required slope and compacting to meet requirement of Tables 300.1 and 300.2 with a lead upto 1000 m as per Technical Specification Clause 301.5 for Rural Roads of MORD. (Mode of measurement: pre works and post works). a) With earth obtained from excavation
Earth work in filling in foundation trenches or plinth with good earth, in layers not exceeding 150 mm. including watering and ramming etc. layer by layer complete. (Payment to be made on the basis of measurement of finished quantity of work) (iv) With carried earth arranged by the contractor within a radius exceeding 5 km. but not exceeding 10 km. including cost of carried earth.
Coarse Sand Filling : Supplying, spreading and compacting Sand to required thickness, in layers not exceeding 150 mm to proper gradient and camber, inundating each layer by water and packing and ramming layer by layer to achieve desired compaction, including lighting, guarding, barricading and making adequate earthen bundh where necessary, curing with water as per direction, mending cracks and depressions by ramming wherever necessary.
Single Brick flat soling of picked jhama bricks including ramming and dressing bed to proper level and filling joint with local sand.
Ordinary Cement Concrete (mix 1 :2:4) with graded stone chips (20 mm nominal size) excluding shuttering and reinforcement, If any, in ground floor. as per relevant IS codes. (a) Pakur Variety.
Controlled Cement concrete with well grade stone chips (20 mm nominal size) excluding shuttering and reinforcement and complete design of concrete as per IS : 456 and relevent special publications, submission of the job mix formula after preliminary mix design after testing of concrete cubes as per direction of Engineer-in-charge. Consumption of cement will not be less than 300 Kg of cement with Super plasticiser per cubic meter of controlled concrete but acrual consumption will be determined on the bais of preliminary test and job mix formula. In ground floor and foundation. [using concrete mixture] M 25 Grade (a) Pakur variety Upto 1st Floor Level
Supplying & laying polythene Sheet (150gm / sq.m.) over damp proof coarse or below flooring or roof terracing or in foundation trenches.
Supplying & laying 3mm thick pre-fabricated plastomericwater proofing membrane conforming to EN 12311-1 &ASTMD 5147, manufactured with atactic poly propylene (APP) modified premium grade asphalt , specially reinforced with non-woven polyester core with polyester reinforcement @160 gms per sqm & both faces covered with thermo-fusible polyethylene film /MineraL on top face over a coat of primer@ 0.40 lit/sqm of manufacturer's specification onsmooth,clean dry surface prepared wherever required.Lap joint shall be provided of 75 mm in longitudinal & 100 mm intransverse direction and fused using LPG/ Propane torch employing extra care ensuring full bondage, complete removal of entrapped air and sealing edges into grooves in appropriate manner as per direction of Engineer -in-charge all complete including materials,labour and applicable taxes. (Payment shall be made on the basis of finishedsurface area.) Membrane Property: Softening Point > 150 deg C, Cold Flexibility < -6 deg C, Tensile Strength, N/cm : 600 (longitudinal), 450 (transverse), Tearing Strength, N: 300 (longitudinal), 200 (transverse)
Pre-Constructional Anti-termite measures: (c) Anti termite treatment to the top surface of the consolidated earth within plinth walls with chemical emulsion by admixing chloropyrofos emulsifiable concentrates (1% concentration) with water by weight at the rate of5 Litres per sq. m. of the surface before sand bed or sub-grade is laid. Holes upto 50 mm. to 75 mm. deep at 150 mm. centre to centre both ways sh all be made with 1 2 mm, diameter mild steel rod on the surface to facilitate saturation of the soil with the chemical emulsion. The work shall be carried out as per specification described in para 6.4 of code IS-6313 (part -II) 1981. ( Mode of measurment will be per Sq.m of plan area of plinth treated.)
Cement concrete with graded stone ballast (40 mm size excluding shuttering) In ground floor (A) Pakur Variety (a) 1:3:6 proportion
Controlled Cement concrete with well grade stone chips (20 mm nominal size) excluding shuttering and reinforcement and complete design of concrete as per IS : 456 and relevent special publications, submission of the job mix formula after preliminary mix design after testing of concrete cubes as per direction of Engineer-in-charge. Consumption of cement will not be less than 300 Kg of cement with Super plasticiser per cubic meter of controlled concrete but acrual consumption will be determined on the bais of preliminary test and job mix formula. In ground floor and foundation. [using concrete mixture]. M 25 Grade (a) Pakur variety Upto 1st Floor
1st Floor to Roof
Roof to Mumty room
M 25 Grade (a) Pakur variety
Hire and labour charges for shuttering with centering and necessary staging upto 4 m using approved stout props and thick hard wood planks of approved thickness with required bracing for concrete slab, beams & columns, lintel curved or straight including fitting , fixing and striking out after completation of works (upto roof of ground floor) (f) 25 mm to 30 mm shuttering without stagging in foundation.
a) 25 mm. to 30 mm. thick wooden shuttering as per decision & direction of Engineer-in-charge.
(c) Steel shuttering or 9 to 12 mm thick approved quality ply board shuttering in any concrete work. Upto 1st floor level
1st floor level to Roof Level
Roof Level to Mumty Room Level
Reinforcement for reinforced concrete work in all sort of structures including distribution bar , stirrups, binders etc initial straightening and removal of loose rust (if necessary), cutting to requisite length, hooking and bendingto correct shape, placing in proper position and binding with 16 gauge black annealed wire at every intersection, complete as per drawing and direction.
M.S. structural works in columns, beams etc. with simple rolled structural members (e.g. joists, angle, channel sections conforming to IS: 226, IS: 808 & SP (6)- 1964 connected to one another with bracket, gussets, cleats as per design, direction of Engineer-incharge complete including cutting to requisite shape and length, fabrication with necessary bolting, metal arc welding conforming to IS: 816- 1969 & IS: 1995 using lectrodes of approved make and brand conforming to IS:814- 2004, haulage, hoisting and erection all complete. The rate includes the cost of rolled steel section, consumables such as electrodes, gas and hire charge of all tools and plants and labour required for the work including all incidental chages such as electricity charges, labour insurance charges etc. I) For structural members of specified section weighing less than 22.5 kg/m.
III) For built up sections / srtuctural members of specified sections weighing not less than 22.5 Kg./m.
M.S. structural works with hollow sections (square or rectangular shape) conforming to IS: 806-1968 & IS:1161-1998) connected to one another with bracket, gusset, cleat as per design, drawing & direction of Engineer-in-Charge complete including cutting to requisite shape & size, fabrication including metal arc welding conforming to IS: 816-1969 & IS: 9595 using electrodes of approved make and brand conforming to IS:814- 2004, haulage, hoisting and erection all complete. The rate includes the cost of all M.S. Hollow section, all consumables such as electrodes, gas and hire charges of all tools and plants and labour reqired for execution and all incidental chages (such as electricity, labour insurance) etc. complete. i) For roof truss works a) Span up to 12 Mtr
Supplying fitting and fixing 600 mm ( ±30 mm) diametre R.B.T (Reinforced Barbed Tape) Concertina fencing on wall top using concertina coils stretched to approx .6 meters length at site clipped with two nos. of horizontal R.B.T strands which will be tensioned and fixed with the vertical M.S angle iron posts by means of security fasteners (such as 'C' clips, R.B.T clips etc.)
Supplying, fitting and fixing windows and ventilators with or without integrated grills conforming to IS 1038-1975 and manufactured from rolled steel sections conforming to IS 7452-1974 with non-friction projecting type, box type hinges, glazing clips, lugs locking bracket, handle plate etc, including hoisting in position, straightening if required, fixing lugs in cement concrete ( 1:2:4) with stone chips 20 mm down cutting holes and mending good damages to match with existing surface complete in all respect excluding glazing. (b) Openable steel windows as per IS sizes with side hung shutters and horizotal glazing bars. [The extra rate admissible for the openable portion only]
(iv) Two point nose steel handle including fitting and fixing.
(vi) steel peg stay 300 mm long including fitting and fixing.
Suppling, fitting and fixing single skin color coated trapezoidal profile for wall cladding, Roof shall be made of 0.45mm BMT (Base Metal Thickness) (0.50mm TCT(Total coated thickness excluding paint), G550 (min 550 yield strength), of Zincalume metallic coating (IS15965) with high Solar Reflectance Index (SRI) value for better colling as per thermatech technology,1000-1015mm effective cover width with five major corrugation, 28mm high rib spaced at 203mm c/c with subtle square fluting in the pan and the end rib shall have anti-capillary groove and return leg.The steel sheet shall be fastened with 40 micron zinc couted or 25 micron zinc-tin alloy coated, hex head, self-drilling screw as per IS 3566-2002 Class 3 fastener. The base steel shall be coated with zinc-aluminium alloy Zincalume (AZ150) (i.e. 55% AI, 43.4% Zinc, 1.6% Si) minimum of 150 g/m2 coating total on both sides, pre-painted with colorbond XRW (xterior roofing, walling) paint system of 35 micron Super Durable Polyester paint (SDP) with stable inorganic pigment with no lead contents confirming IS15965. The sheet shall be free from defects and have brand marking of the manufacturer giving product details on the back of the sheet at regular interval confirming genuinity of the material. (i) In Roof:- a) With 0.5 mm thick sheet
Aluminium sheet ridging fitted with self tapping screws, EPDM washers etc complete.(Minimum 225mm end lapping). (A) 300 mm lapping each way (a) With 0.71 mm sheet
(b) With 0.91 mm sheet
Supplying fitting and fixing 4mm thick acrylic ornamental finger plate made of transparent acrylic sheet including providing holes of knobs and keys as per existing shutter and chamfering the edges of the acrylic sheet.
Galvanised or painted wind-tie made of M.S. flats, fitted and fixed complete including cost of necessary fittings (c) Made with 50 mm. X 10 mm. flats.
Holding down bolt with nut including 100 x 100 x 6 mm plate washer at bottom fitted complete and packing the hole with cement concrete or cement grout as directed. (ii) 20 mm dia bolt (b) 450 mm long
(b) 600 mm long
Labour for chipping of concrete surface before taking up plastering work
Brick work with 1st class bricks in cement mortar (1:6) (a) In foundation and plinth
(b) In superstructure, ground floor
1st floor
Mumpty Room
125 mm thick Brick work with 1st class bricks in cement morter (1:4) Ground floor
1st Floor
Parapat Wall
(a) 75 mm. thick brick work with 1st class bricks set in cement, sand mortar (1:4) in ground floor including H.B. netting in every alternate layers.
Extra for using approved H.B netting in every thired layer in 16 & 17 of subhead A above in any floor.
Plaster (to wall. floor. ceiling etc.) with sand and cement mortar including rounding off or chamfering corner.; as directed and raking out joints or rougening of concrete surface, including throating, nosing and drip course where necessary (ground floor). (i) With 1:6 cement mortar (b) 20 mm. thick plaster Ground floor
1st Floor
Mumty Room
(c) 15 mm. thick plaster Ground floor
1st Floor
(ii) With 1:4 cement mortar (c) 10 mm thick plaster Ground floor
1st Floor
Artificial stone in floor. dado. staircase etc. with cement concrete (4:2:1) with stone chips, laid in panels as directed with topping made with ordinary or white cement (as necessary) and marble dust in proportion (2:1) including smooth finishing and rounding off corners and including application of cement slurry before flooring works, using cement @1.75 kg/Sq.Mall complete including all materials and labour. (iii) 35 mm. thick
Labour for chipping of con crete surface before taking up plastering work
Neat cement punning about 1.5 mm. thick in wall, dado, window, sills, floor, drain etc. Ground Floor
Supplying. fitting & fixing 1st quality Ceramic tiles in walls and floor.; to match with the existing work & 4 nos. of key stones (1 Om m) fixed w th a raid ite at the back of ea ch tile & finishing the joints with white cement mixed with colouring oxide if required to match the colour of tiles including roughening of concrete surface, if necessary or by synthetic adhesive & grout materials etc . (A) Floor With Sand Cement Mortar (1 :4) 20 mm thick & 2 mm thick cement slurry at back side of tiles using cement@ 2.91 Kg/Sq.m & joint filling using white cement slurry@ 0.20kg/Sq.m. (b) Area of each tile above 0.09 Sq.m (i) Coloured decorative
(ii) Other than Coloured decorative including white
(B) Wall With Sand Cement Mortar (1:3) 15 mm thick & 2 mm thick cement slurry at back side of tiles using cement @ 2.91 Kg/Sq.m & joint filling using white cement slurry @ 0.20kg/Sq.m. (b) Area of each tile above 0.09 Sq.m (i) Coloured decorative
25 mm. thick damp proof with cement concrete (1:1.5:3) (with graded stone aggregate 10 mm. normal size) and painting the top surface with a coat of bitumen [VG.40 ] using 1.7 kg. per sq.m. including heating the bitumen and cost and carriage of all materials complete. [Bitument to be supplied by the Agency]
18 mm. to 22 mm. thick, kota stone slab set in 20 mm thick (avg) cement mortar (1:4) in floor, stair & lobby including pointing in cement slurry with admixture of pigment matching the stone shade, including grinding & polishing as per direction of Engineer - in - charge to match with the existing work. [Slurry for bedding @ 4.4 kg/Sq.m and pointing @2.0 kg/Sq.m]
Extra cost of labour for grinding Kota Stone Floor in treads and riser of Steps
Extra cost of labour for prefinished and premoulded Nosing to treads of steps, railing, window sill etc. of Kota Stone.
Supplying, fitting and fixing 18 mm. to 22 mm. thick kota stone slab in wall, dado in 15 mm thick [avg] cement mortar (1:3) including making suitable arrangement to hold the stone properly by brass / copper hooks including pointing in cement mortar (1:2) (1 cement : 2 marble dust) with admixture of pigments matching the stone shade, including grinding and polishing all complete as per direction of Engineer-in-charge including cost of materials, labour, scaffolding, staging, curing complete. [Using cement slurry for bedding @4.4 kg/Sq.m and for jointing @1.8 kg/Sq.m]
Supplying and laying true to line and level Anti-Skid, Full Body, Homogeneous & Granular finish Vitrified Tiles conforming to IS:15622-2006 & IS 4457-2007 and testing shall be made in accordance with IS:13630 [Non- modular sizes for tiles with Skid resistance > 0.5, Mohr's hardness > 5.0, Staining resistance: Class-1, Water Absorption: E < 0.5%], MOR > 35 N/sq.mm in Internal area of building e.g. Toilet Block, Passage, Corridor, Accessible Open Terrace etc. seti n 20 mm sand cement mortar (1:4) and 2 mm thick cement slurry at back side of tiles using cement @ 2.91 Kg./Sqm or using Polymerised Adhesive (6 mm thick layer applied directly over finished artificial stone floor/ Mosaic etc without any backing course) laid after application slurry using 1.75 Kg of cement per Sqm below mortar only, joints grouted with admixture of white cement and colouring pigment to match with colour of tiles/ epoxy grout materials of approved make as directed and removal of wax coating of top surface of tiles with warm water and polishing the tiles using soft and dry cloth upto mirror finish complete including the cost of materials, labour and all other incidental charges complete true to the manufacturer's specification and direction of Engineer-in-Charge. (White cement, synthetic adhesive and grout material to be supplied by the contractor). Ground Floor
1st Floor
Supplying and laying true to line and level vitrified tiles of approved brand (size not less than 600 mm X 600 mm X 10 mm thick) in floor, skirting etc. set in 20 mm sand cement mortar (1:4) and 2 mm thick cement slurry back side of tiles using cement @ 2.91Kg./sqM or using polymerised adhesive (6 mm thick layer applied directly over finished artificial stone floor/Mosaic etc without any backing course) laid after application slurry using 1.75 Kg of cement per sqm below mortar only, joints grouted with admixture of white cement and colouring pigment to match with colour of tiles / epoxy grout materials of approved make as directed and removal of wax coating of top surface of tiles with warm water and polishing the tiles using soft and dry cloth upto mirror finish complete including the cost of materials, labour and all other incidental charges complete true to the manufacturer's specification and direction of Engineer-in-Charge. (I) With application slurry @1.75 kg/ Sq.m, 20 mm sand cement mortar (1:4) & 2 mm thick cement slurry at back side of tiles, 0.2 kg/ Sq.m white cement for joint filling with pigment. (A) Deep Colour & White
Wood work in door and window frame fitted and fixed in position complete including a protective coat of painting at the contact surface of the frame exluding cost of concrete, Iron Butt Hinges and M.S clamps. (The quantum should be correted upto three decimals) Ground Floor.
1st Floor
Supplying, Fitting & Fixing Factory made prelaminated P.V.C. door frame of size 50 mmx47 mm with a wall thickness of 5 mm, made out of extruded 5 mm Prelaminated PVC sheet miter cut at two corners and joined with two nos of 1.5 mm long brackets of 15 mm x15 mm M.S. square tube. The two vertical door profiles are to be reinfonced with 19 mmx 19 mm M.S. Square tube of 19 gauge, weather seal to be provided through out the frame. The door frame shall be fixed with the wall using 65/100 mm M.S. Screws through the frame by using P. V.C fasteners. A minimum of 4 Nos of screws to be provided for each vertical member and minimum 2 Nos for horizontal member etc. complete as per Manufacturer's specification and direction of Engineer-in-Charge.
Supplying, fitting and fixing fibre reinforced polymer (FRP) Composite door frame as per approved section with glass fibre reinforced plastic moulded skins and a special sandwich core, so as to impart monolitaheic composite structure as per approved technology of Department of Science and Technology (DST) to safisfy IS: 4020 door testing performance criteria.(i) 66mm x 90mm
Supplying solid flush type doors of commercial quality, the timber frame consisting of top and bottom rails and side styles of well seasoned timber 65mm wide each and the entire frame fitted with 37.5mm wide battens places both ways in order to make the door of solid core and internal lipping with Garjan or similar wood veneers using phenol formaldehyde as glue etc. complete, including fitting, fixing shutters in position but excluding the cost of hinges and other fittings in ground floor. (a) 35 mm thick shutters (single leaf)
Supplying, Fitting & Fixing 30 mm thick both side prelaminated Factory made solid Panel PVC Door Shutter consisting of outer frame made out of M.S. tubes of 19 gauge thickness and size 19 mmx19 mm for styles, top and bottom rails, M.S. frame shall have cost of steel primers of approved make and manufacture, M.S. frame covered with 5 mm th. heat moulded PVC "C" channel of size 30 mm th, 70 mm width out of which 50 mm shall be flat and 20 mm shall be tapered in 45 degree angle on either sides forming styles; and 5 mm th. 95 mm wide PVC sheet out of which 75 mm shall be flat and 20 mm tapered in 45 degree on the inner side to form top & bottom rail and 115 mm wide PVC sheet out of which 75mm shall be flat and 20 mm shall be tapered on both sides to form lock rail. Top, bottom and lock rails shall be provided either side of the panel with 10 mm (5 mmx2)th.,20 mm wide cross PVC sheet as gap insert for top rail and bottom rail sheet to be fitted in the M.S. frame welded/sealed to the styies &rails with 7 mm (5 mm+2 mm) th.x15 mm wide PVC sheet beading on inner side and joined together with solvent cement adhesive. An additional 5 mm th. PVC strip of 20 mm which is to be stuck on the interior side of the "C" channel using PVC solvent adhesive etc. complete excluding all necessary hardwares as per direction of Engineer-in-Charge.
Supplying, fitting & fixing fibre reinforced polymer (FRP) Composite door shutters as per approved design with glass fibre reinforced plastic moulded skins and a special sandwich core, so as to impart monolitaheic composite structure as per approved technology of Department of Science and Technology (DST) to satisfy IS:4020 door testing performance criteria. (i) 32 mm thick
Labour charge for fabrication and installation of composite door, window, partitions made from annodized extruded alloy aluminium sections for the following units: (A) Glazed aluminium sliding windows made of extruded and annodized alloy aluminium sectios, fabrications, including cutting to proper shape and size,drilling and aligning of window shutter frame fitted within built locking arrangements, sliding roller sand other necessary fittings,fixture, adhesives and joineries along with extruded neoprine or EPDM gasketing in between window frame and masonrywork (walls, column, beam.lintelsetc.)as well as between glassand shutter frame for fixing glass and Polysulphide sealant and in between shutter and window frame wherenecessary includingcutting to requisitesizeand fixing glassas per drawing, specification and direction of EIC. The rate includes the hire charge of all tool sand plants, including all incidental charges, adhesive, join eries such as screw, cleatangleetc. but excluding the cost of extruded aluminium sections, glass, neoprene / EPDM gasket, locking arrangement and rollers. ii ) 3 /4 track sliding window.
Supplying profiles of required section made of Aluminium Alloy Extrusionscon forming to IS:732-1983 and IS:1285-1975; Annodized (with required film thickness and specified colour /natural) mattfinished conforming to IS:1868-1983 for fabrication of composit door, sliding & casement windows, partitions, formed of basic sections of any ISI embossed/ certified make and brand as per direction of Engineer-In Charge. (Payment will be made on finished length of the work). b) 3- track sliding window i) Bottom frame
ii) Top and side frame.
Supplying bubble free float glass of approved make and brand conforming to IS: 2835-1987. vi) 6mm thick coloured / tinted / smoke glass.
Supplying EPDM gusket of approved make and brand as per direction of Engineer in charge. i) For sliding windows b) 'U' shaped EPDM gasket for frames.
Supplying maruti lock (100mm)
Supplying PVC rollers for sliding windows as per direction of Engineer in charge.
Supplying best Indian sheet glass panes set in putty and fitted and fixed with nails and putty complete. (In all floors for internal wall & upto 6 m height for external wall). (ii) 4 mm thick
Extra for fixing glass panes in steel window.
Collapsible gate with 40mm x 40mm x 6mm Tee as top and bottom guide rail, 20mm x 10mm x 2mm vertical channels 100mm apart in fully stretched position 20mm x 5mm M.S. flats as collapsible bracings properly rivetted and washered including 38mm steel rollers including locking arrangements, fitted and fixed in position with lugs set in cement concrete and including cutting necessary holes, chasing etc. in walls, floors etc. and making good damages complete.
Supplying, fitting and fixing M.S. clamps for door and window frame made of flat bent bar, end bifurcated with necessary screws etc. by cement concrete(1:2:4) as per direction. (Cost of concrete will be paid separately). (a) 40mm X 6mm, 250mm Length
Iron butt hinges of approved quality fitted and fixed with steel screws, with ISI mark. (i) 50mm. X 37mm. X 1.50mm.
(iv) 75mm. X 47mm. X 1.70mm.
(viii) 100mm. X 75mm. X 3.50mm.
Anodised aluminium barrel / tower / socket bolt (full covered) of approved manufactured from extruded section conforming to I.S. 204/74 fitted and fixed with cadmium plated screws: (ix) 300mm long x 10mm dia. bolt.
(iv) 150mm long x 10mm dia. bolt.
Anodised aluminium Aldrop / Sliding bolts of approved quality manufactured from extruded section conforming to I.S. specification (I.S. 2681/66) fitted and fixed complete. (iii) 300mm x 16mm dia. bolt.
Anodised aliminium D-type handle of approved quality manufactured from extruded section conforming to I.S. specification (I.S. 230/72) fitted and fixed complete: (a) With continuous plate base (Hexagonal/ Round rod) (vi) 150 mm grip x 10 mm dia rod.
(i) 75 mm grip x 10 mm dia rod.
Iron socket bolt of approved quality fitted and fixed complete. (b) 100mm long x 10mm dia bolt for FRP Door
Renewing 125mm long wooden buffer block ii) With Sal : Malayasian
Supplying, fitting and fixing hinge cleat in position excluding the cost hinge and other fiffitngs. a) with 50mm iron Butt-hinge ii) Sal : Malayasian
(a) Supplying 'Godrej' mortice lock chromium plated with latch and keys 4 levers, including fitting and fixing complete.
i) Hydraulic door closer of approved quality as per I.S.I. standard fitted and fixed complete. (b) Medium (I.S.I. size 2)
b) Priming one coat on timber or plastered surface with synthetic oil bound primer of approved quality including smoothening surfaces by sand papering etc.
(a) Priming one coat on steel or other metal surface with synthetic oil bound primer of approved quality including smoothening surfaces by sand papering etc.
(A) Painting with best quality synthetic enamel paint of approved make and brand including smoothening surface by sand papering etc. including using of approved putty etc. on the surface, if necessary : (b) On steel or other metal surface : (iv) Two coats (with any shade except white)
(a) On timber or plastered surface : With super gloss (hi-gloss) - (iv) Two coats (with any shade except white)
Applying Interior grade Acrylic Primer of approved quality and brand on plastered or cencrete surface old or new surface to receive Distemper/ Acrylic emulsion paint including scraping and preparing the surface throughly, complete as per manufacturer's (b) One Coats ii) Water based interior grade Acrylic Primer
Applying Acrylic Emulsion Paint of approved make and brand on walls and ceiling including sand papering in intermediate coats including putty (to be done under specific instruction of Superintending Engineer) : (Two coats)
Applying Exterior grade Acrylic primer of approved quality and brand on plastered or cencrete surface old or new surface to receive decorative textured(matt finish) or smooth finish acrylic exterior emulsion paint including scraping and preparing the surface throughly, complete as per manufacturer's specification and as per direction of the EiC. a) Two Coat Ground Floor
1st Floor
Synthetic Distemper to interior wall, ceiling with a coat of solvent based interior grade acrylic primer (as per manufacturer's specification) including cleaning and smoothning of surface. Two Coats
Protective and Decorative Acrylic exterior emulsion paint of approved quality, as per manufacturer's specification and as per direction of EiC to be applied over acrylic primer as required. The rate includes cost of material, labour, scaffolding and all incidental charges but excluding the cost of primer. a) Normal Acrylic Emulsion Ground Floor (Qty same as Item no 38.0)
1st Floor
b) Premium 100% Acrylic Emulsion Ground Floor
1st Floor
White washing including cleaning and smoothening surface thoroughly (5parts of stone lime and 1 part of shell lime should be used in the finishing coat). All floors: (c) Three coats (on new works only).
Supplying, filling and fixing UPVC pipes A- type and fillings conforming to IS:13592-1992 with necessary clamps nails including making holes in walls, etc. and culling trenches in any soil, through masonry concrete structure etc. if necessary and mending good damages including jointing with jointing materials ( Spun yam, valamoid / bitumen / M. seal etc.) complete. A) UPVC Pipes (ii) 110 mm. Dia.
c) Bend 87 .5 degree (ii) 110 mm. Dia
d) Shoe (ii) 110 mm. Dia
Supplying and laying true to line and level 20 mm / 25 mm. thick precast roof tiles made of cement conc. with stone chips as per approved strength and density set in 25mm avg. thick cement morter(1:3) and filling up joint (3 mm wide) with cement sand mortar (1:1) applying cement slurry @ 1.75 kg per Sq.m back of tiles and then settting close the precast tiles, finishing up the joints with slurry already laid and finally finishing the top surface including providing 150 mm. high skirting with the same tiles flushed with the inside surface of parapet wall,finishing the mouth of rain water pipes, curving etc. as necessary complete as per direction of the Engineer-in-charge. (Levelling if necessary may be paid separately) (b) For 25 mm. thick precast tiles (cement 14.6 kg/ Sq.m for underlayer)
(a) Supplying, fitting and fixing steel rolling shutter profile type with 18 B.G . of approved type steel latche section 75mm wide, fitted with coil wire spring to necessiate the fitting of required Nos. of C.I. Pulleys on heavy type solid drawn seamless steel tube complete with locking arrangements both inside and outside specially builtup side guide channels including providing a hood for the steel rolling shutter in the room, painting two coats of approved aluminium paint over a coat of red lead primer complete. 1. (Measurement will be made on the area of opening covered by the rolling shutter corrected upto 2 decimal.)
(a) M.S.or W.I. Or namental grill of approved design joints continuously welded with M.S, W.I. Flats and bars of windows, railing etc. fitted and fixed with necessary screw sandlugs in ground floor. (i) Grill weighing above 10 Kg./sq.mtr and up to 16 Kg./sq. mtr.
(i) Grill weighing above 10 Kg./sq.mtr and up to 16 Kg./sq. mtr.
(ii) Grill weighing above 16 Kg./sq.mtr and above
(b) Extra for work in grill gate. (I) For hanging and locking arrangements including supply of materials and labour complete. (15% extra over the corresponding item of grill )
(ii) For supplying fitting and fixing bottom rollers including all labour complete.
(15% extra over the corresponding item of grill )
Square or hexagonal mesh netting made with 18B.W.G.galvanised wire, fitted and fixed complete as per design (excluding the supporting framework but including local sal wood battens of size 37.5mmx25mm). In ground floor. (c) 37.5mm mesh
Supplying and laying true to line and level Tactile Finish Scratch resistant, Neutral to UV rays, Non-fade, High Slip Resistant Full Body Vitrified Tiles conforming to IS:15622-2006 & IS :4457- 2007 and tested in accordance with IS:13630 [Non- modular sizes for tiles with Skid resistance: 0.6, Mohr's hardness > 7.0, Staining resistance: Class-1, Water Absorption E < 0.5%], MOR > 38N/sq.mm & Breaking strength > 4000 N for Outdoor area of building e. g. Driveway, Pathway, Pavements, Parking lots, Sloping ramps, Entrance lobbies, Patios, Portico, swimming pool enclosure, Bus Passenger Shed & directing visually impaired persons, set over necessary underlay and 2 mm thick cement slurry at back side of tiles using cement @ 2.91 Kg./Sqm, joints grouted with admixture of white cement and colouring pigment to match with colour of tiles and removal of wax coating of top surface of tiles with warm water and cleaning the tiles using soft and dry cloth complete including the cost of materials, labour and all other incidental charges complete including backside slurry but excluding the cost of underlay and true to the manufacturer's specification and direction of Engineer-in-Charge.In Ground Floor: Sizes-300 mm x 300 mm x 15 mm
Constructing Inspection pit of inside measurement 600mm X 600mm X upto 600mm (depth) with 250 mm thick 1st. class brick work in cement mortar (1:4) on all sides, bottom of the pit consisting of 100 mm thick cement concrete (1:3:6) with stone chips over a layer of jhama brick flat soling, 15 mm thick (1:4) cement plaster to inside walls and out-side walls upto G.L. and 20 mm.thick (1:4) plaster to bottom of the pit, providing necessary invert with cement concrete (1:3:6) with stone chips as per direction, neat cement finishing to entire internal surfaces, top of the pit covered with100 mm thick R.C.C. slab (1:1.5:3) with stone chips and necessary reinforcements upto 1% and shuttering including 6 mm thick cement plaster (1:4) in all external surfaces of the slab and one 560 mm dia. R.C.C. manhole cover of approved make supplied, fitted and fixed in the slab with necessary fittings, necessary earthwork in excavation in all sorts of soil, filling sides of the pit with earth and removing spoils after work complete in all respect with all costs of labour and materials. i) With Pakur variety. (SAIL/TATA/RINL)
Constructing Inspection pit to a depth of 1.5 metre (inside), 250 mm thick 1st class brick work (1:4) in all sides over a layer of jhama brick soling and 150 mm thick cement concrete with stone chips (1:3:6) including necessary earth work, fitting and fixing approved type S.W. master trap, constructing masonry invert with cement concrete (1:1.5:3) with stone chips, plastering inside and outside (outside upto 300 mm below G.L.) with 20 mm thick cement plastering (1:4) and neat cement punning, including supplying,fitting and fixing one 560 mm. dia R.C.C. manhole cover of approved make with R.C.C. slab of 100 mm thick with cement concrete (1:1.5:3) with stone chips including necessary reinforcement (upto 1%) and shuttering and necessary corbelling brick work (1:4) so that the R.C.C. cover slab rests 150 mm above adjucent G.L., cement plaster (1:4) 10 mm thick on all external surfaces of the top slab as directed complete in all respect and removal of surplus earth with all costs of labour and materials (excluding the cost of master trap only). A) With Pakur variety. (SAIL/TATA/RINL)
(i) 35 MT load bearing capacity round manhole cover provided with two lifter hooks fitted with matching frame of size Cover: 700 mm X 100 mm Frame: 910 mm X 185 mm opening: 560mm Weight: 245 kg (approx) 900 mm X 750 mm manhole
(viii) 5 MT load bearing capacity gully pit cover with frame and hinge Cover: 470 mm X 420 mm X 80 mm Frame: 590 mm X 550 mm X 170 mm opening: 380mm x 305mm 600mm X 600mm manhole
Supplying, fitting, fixing C.I Grating (Heavy type). (a) Up to 100 mm Square or 100 mm Dia. 600mm X 600mm manhole
900 mm X 750 mm manhole
Removal of rubbish,earth etc. from the working site and disposal of the same beyond the compound, in conformity with the Municipal / Corporation Rules for such disposal, loading into truck and cleaning the site in all respect as per direction of Engineer in charge.
Supplying & laying Double Wall Corrugated (with external annular corrugation and smooth internal walls) High Density Polyethelene Pipes conforming to IS 16098 (Part-II):2013 having Stiffness Class of SN 8 with Ring Stiffness not less than 8.00 KN/Sqm. and Impact Resistance TIR value not more than 10% including necessary jointing materials for nonpressure underground Drainage, Sewerage & Cross drainage application. DWC pipes ( 500 dia)
Packing the annular space between the outside of the tube well pipes & strainers and the bore with pea size washed gravel of approved quality having size from 2 mm to 5 mm or the size approved by the Engineer incharge including cost of all materials labour and equipment complete. 110 mm. Dia Rain water pipe (50%)
Packing annular space between the outside of the housing pipe and the bore with puddled clay balls of approved size as per direction of the Engineer-in-charge with cost of all materials and labour complete. 110 mm. Dia Rain water pipe(50%)
Labour for boring through any type of soil for sinking tube well of required dia. with top enlargement by rig boring system (either by reserve circulation or by direct rotary method) including hire charges and labour for rig machine, tools and plants, staging, force pumping set and making arrangement for water required for boring etc. complete and lowering of pipes, strainers, blind pipes etc. complete. (a) For depth upto 250 metre for 100 mm dia. Tube well with top enlargement of 200 mm dia.(upto 50 metre). (i) First 50 metre
(ii) Next 50 metre
(iii) Next 50 metre
Supply of PVC pipes & fittings Schedule 80 (medium duty) conforming to ASTMD - 1785 and threaded to match with GI Pipes as per IS : 1239 (Part - I). (A) PVC Pipes 80 mm dia
150 mm dia
Supplying, fibre glass reinforced Epoxy resin slotted of 1 mm slot width in 6.1m length of approved make and as per direction of the Engineer - in - Charge (a) 100 mm nominal dia (i) 6.00 mm wall thickness
Geophysical investigation of the acquifer by electrologging system with all tools and plants as necessary including supply of necessary report.
Providing and fixing bell plug as required upto 250 mm (internal) dia. ERWMS pipe including cost of materials and labour complete.
Supplying, fitting and fixing 300 mm M.S. housing clamp of approved quality.
Supplying, fitting and fixing heavy type bell mouth reducing socket. (ii) 100 mm X 150 mm
Supplying, fitting and fixing G.I. cap at top (iii) 200 mm
Washing and developing tube well with air compressor pump and engine for 8 (eight) hours continuous pumping per day with necessary arrangements for testing the yield in gallons per hour with 'V' notch including hire and labour charges for all tools and plants and scaffolding as required.
Labour for making arrangement for showing verticality test including the cost for hire charges of tools and plants, scafolding, labour etc. all complete.
Collecting sample of water for bacteriological and chemical test from any depth at any time during execution of work including hire and labour charges for tools and plants and sterilising the equipments, paying all charges and fees, testing etc. complete in all respect as per direction.
Supplying M.S. male / female adopter of approved make and brand for coupling of M.S. pipe and fibre glass strainers, as per direction of the Engineer - in - Charge. (i) 100 mm
Providing 200 mm centre guide. i) With Clamp
Submersible Pumpset & Accessories Supplying, fitting, fixing and lowering inside the tubewell submersible pump having delivery outlet fitted in spring loaded non return valve capable of delivering required discharge and against a total head from all cases ( Duty conditions given below )directly coupled with submersible motor of reqd. HP to give the required discharge suitable for operation 340-400 volts plus minus 8%, 3 phase, 50 c/s AC supply. The materials of pump and motorsshaft aluminium bronze thrust bearing plate. Noryl diffuser, with necessary accessories and cables for submersible pumping set of approved make / model and tubewell top cover suitable for pump set (before procurement, manufacturer's test report / performance curve chart etc. to be submitted for approval) (KSB / Pluga) Q = 15 m3/hr, H = 30 m ( 1W+1S).
Supplying & Laying of 2.5 Sqm Submursible Flat Cu . Cable with 25mm GI Pipe.
Supplying , Fitting & Fixing 50mm dia GI Pipe (ISI Marked) Colum Pipe for Surmuersible Pump lowering having 3m avarage including spacial threading in leath &S&F one GI Socket.
Making of Brick Piller of Suitable size with Neat Cement plastering for Supporting lead / Plumbing line as per instruction of E.I.C.
S&f of 50 mm dia non return valve (horizontal) with jointing material.
S & f of 50 mm dia check valve with flanger as required.
supply fabrication & installation of header assembly made of 150 mm dia 1.2 mtr long black ms pipe having both side sealed by weiding provision.
supplying & lying 1.1 kv gr 4 core 10 sqmm PVC/A cabel on wall/ surface and S&F MS saddles with earthing attachment in 10 swg.
S&F compression type cable gland suitable for 4 core 10 sqm PVC/A.
Finishing for cable ends by comprising method for 4x10 sqm PVC/A.
Suppling and commissioning NEW ISI Marked ABC type Fire Extinguisher 09kg with store pressure & squeeze lever valve conforming to IS: 15683., all complete.
Supplying & fixing fire buckets in wall (FILLED WITH SAND) round bottom type enamel painted, white inside & Red out side and Letter "FIRE" in black out side and handle with mounting bracket complete conforming to IS:2546.
(i) Weigh Bridge Machine
Supplying, fitting and fixing PVC pipes for underground work of approved make of Schedule 80 (medium duty) conforming to ASTMD - 1785 and threaded to match with GI Pipes as per IS : 1239 (Part - I). with all necessary accessories, specials viz. socket, bend, tee, union, cross, elbo, nipple, longscrew, reducing socket, reducing tee, short piece etc. fitted including cost of all materials ,jointing materials, cutting pipes, making threads ,cutting trenches upto 1.5 metre below surface in all sorts of soil and refilling the same as directed complete in all respect. (Payment will be made on the centre line measurement of the total pipe line including all specials No separate payment will be made for accessories, specials.) PVC Pipes (Dia) 20 mm
Supplying, fitting and fixing 10 litre P.V.C. low-down cistern conforming to I.S. specification with P.V.C. fittings complete,C.I. brackets including two coats of painting to bracket etc.
Supplying P.V.C. water storage tank of approved quality with closed top with lid (Black) - Multilayer (b) 1000 litre capacity
(d) 2000 litre capacity
Labour for hoisting plastic water storage tank. (i) Upto 1500 litre capacity. (a) Upto 1st story from G.L.
(b) Extra for each additional story
(ii) Above 1500 litre upto 5000 litre capacity. (a) Upto 1st story from G.L.
Labour for punching hole in plastic water storage tank upto 50 mm dia.
Supplying, fitting and fixing white vitreous china best quality approved make wash basin with C.I. brackets on 75 mm X 75 mm wooden blocks, C.P. waste fittings of 32 mm dia. one approved quality brass C.P. pillar cock of 15 mm dia., C.P. chain with rubber plug of 30 mm dia., approved quality P.V.C. waste pipe with C.P. nut 32 mm dia., 900 mm long approved quality P.V.C. connection pipe with heavy brass C.P. nut including mending good all damages and painting the brackets with two coats of approved paint. (ii) 550 mm X 400 mm size
Supplying, fitting and fixing pedestal of approved make for wash basin (white)
Supplying, fitting and fixing pillar cock of approved make. a) (i) CP Pillar Cock - 15 mm. (Equivalent to Code No. 507 & Model -Tropical / Sumthing Special of ESSCO or similar brand).
Supplying, fitting and fixing stainless steel sink complete with waste fittings and two coats of painting of C.I. brackets. (ii) 630 mm X 550 mm X 180 mm
(a) Sink only (i) 530 mm X 430 mm x 180 mm
Supplying,fitting and fixing approved brand 32 mm dia.P.V.C. waste pipe, with PVC coupling at one end fitted with necessary clamps. (ii) 750 mm long
Supplying, fitting and fixing shower of approved brand and make.(a) (i) Chromium plated round shower with revolving joint 100 mm dia with rubid cleaning system (Equivalent to Code No. 542(N) & Model - Tropical / Sumthing Special of ESSCO or similar brand).
(f) Hand Shower(Health Faucet) with 1mtr Fexible Tube with Wall Hook(Equivalent to Code No.573 & Model -ALLIED of Jaquar or similar).
Peet's valve fullway gunmetal standard pattern best quality of approved brand bearing I.S.I. marking with fittings (tested to 21 kg per sq. cm.). (v) 40 mm dia
(vii) 25 mm dia
Supplying, fitting and fixing bib cock or stop cock. (a) (i) Chromium plated Bib Cock short body (Equivalent to Code No. 511 & Model - Tropical / Sumthing Special of ESSCO or similar brand).
(b) (i) Chromium plated Stop Cock (Equivalent to Code No. 513(A) & 513(B) & Model - Tropical / Sumthing Special of ESSCO or similar
(d) (i) Chromium plated angular Stop Cock with wall flange (Equivalent to Code No. 5053 & Model - Florentine of Jaquar or similar brand).
(Ref : Page - 212, Item - 21) P.W.D Building Schedule_2017 Supplying, fitting & fixing UPVC pipes A- Type and fittings conforming to IS:13592-1992 with all necessary clamps nails, including making holes in walls, floor etc. cutting trenches in any soil through masonry concrete structures etc if necessary and mending good damages including joining with jointing materails (Spun Yarn, Valamoid/Bitumen/M-Seal etc) complete. A) UPVC Pipes: (ii) 110 mm
B) UPVC Fittings: (a) Plain Tee (ii) 110 mm
b) Plain Y (ii) 110 mm
c) Bend 87.5 degree (ii) 110 mm. Dia.
d) Shoe (iii) 160 mm. Dia.
A) UPVC Pipes: (iii) 160 mm
B) UPVC Fittings: c) Bend 87.5 degree (iii) 160 mm. Dia.
d) Shoe (iii) 160 mm. Dia.
xviii) W.C. Connector (450 mm long) W / lipring 75 mm
Supplying, fitting and fixing E.W.C. in white glazed vitreous chinaware of approved make complete in position with necessary bolts, nuts etc. (a) With 'P' trap
Suppling, fitting and fixing Orissa pattern water closet of white glazed vitreous chinaware of approved make and brand in position complete excluding 'P' or 'S' trap (excluding cost of concrete for fixing).
Suppling, fitting and fixing Wall mounted water closet of white glazed vitreous chinaware of approved make and brand in position complete with necessary nut and boalts (Equivalent to Code No. 20061 or 92065 & Model Studio or Rubbic of Hindware or equivalent.)
Supplying, fitting and fixing Flat back urinal (half stall urinal) in white vitreous chinaware of approved make in position with brass screws on 75 mm X 75 mm X 75 mm wooden blocks complete. (i) 635 mm X 395 mm X 420 mm
Supplying, fitting and fixing Squating plate with integral flushing in white vitreous chinaware of approved make in cement concrete (6:3:1) with jhama chips complete. (Payment of concrete will be paid seperately). (i) 450 mm X 350 mm
Supplying, fitting and fixing Closet seat of approved make with lid and C.P. hinges, rubber buffer and brass screws complete. (a) E.W.C. (ii) Plastic (hallow type) white
Supplying, fitting and fixing Foot rest for water closet of size 275 mm X 125 mm with (b) Porcelain of approved make.
Supplying, fitting and fixing 18 mm thick marble partition slab with chawk doongri marbel square cut, both sides polished with two front corners rounded and edges polished.
Supplying, fitting and fixing best quality Indian make mirror 5.5 mm thick with silvering as per I.S.I. specifications supported on fibre glass frame of any colour, frame size 550 mm X 400 mm
Supplying, fitting and fixing soap holder. (a) PTMT (Prayag or equivalent)
Supplying, fitting and fixing towel rail with two brackets. (a) C.P. over brass (ii) 25 mm dia. and 600 mm long
Constructing Inspection pit of inside measurement 600mm X 600mm X upto 600mm (depth) with 250 mm thick 1st. class brick work in cement mortar (1:4) on all sides, bottom of the pit consisting of 100 mm thick cement concrete (1:3:6) with stone chips over a layer of jhama brick flat soling, 15 mm thick (1:4) cement plaster to inside walls and out-side walls upto G.L. and 20 mm.thick (1:4) plaster to bottom of the pit, providing necessary invert with cement concrete (1:3:6) with stone chips as per direction, neat cement finishing to entire internal surfaces, top of the pit covered with 100 mm thick R.C.C. slab (1:1.5:3) with stone chips and necessary reinforcements upto 1% and shuttering including 6 mm thick cement plaster (1:4) in all external surfaces of the slab and one 560 mm dia. R.C.C. manhole cover of approved make supplied, fitted and fixed in the slab with necessary fittings, necessary earthwork in excavation in all sorts of soil, filling sides of the pit with earth and removing spoils after work complete in all respect with all costs of labour and materials. i) With Pakur variety. (SAIL/TATA/RINL)
Constructing Inspection pit to a depth of 1.5 metre (inside), 250 mm thick 1st class brick work (1:4) in all sides over a layer of jhama brick soling and 150 mm thick cement concrete with stone chips (1:3:6) including necessary earth work, fitting and fixing approved type S.W. master trap, constructing masonry invert with cement concrete (1:1.5:3) with stone chips, plastering inside and outside (outside upto 300 mm below G.L.) with 20 mm thick cement plastering (1:4) and neat cement punning, including supplying,fitting and fixing one 560 mm. dia R.C.C. manhole cover of approved make with R.C.C. slab of 100 mm thick with cement concrete (1:1.5:3) with stone chips including necessary reinforcement (upto 1%) and shuttering and necessary corbelling brick work (1:4) so that the R.C.C. cover slab rests 150 mm above adjucent G.L., cement plaster (1:4) 10 mm thick on all external surfaces of the top slab as directed complete in all respect and removal of surplus earth with all costs of labour and materials (excluding the cost of master trap only). (i) 900 mm X 750 mm (inside) chamber including fitting and fixing S.W. master trap of 150 mm dia. of approved make A) With Pakur variety. (SAIL/TATA/RINL)
Construction of septic tank of different capacities as per approved drawing with 1st class brick work in cement mortar (1:4) including two 560 mm dia. R.C.C. manhole cover(heavy type)of approved make supplied, fitted and fixed in the 100mm thick R.C.C (1:1.5:3) top slab with necessary fittings, 20mm thick cement plaster (4 : 1) with neat cement finish to the internal surfaces and 15 mm thick cement plaster (4 : 1) to outside wall upto 200 mm below G.L floor finished with 25 mm thick grey artificial stone over 100 mm thick R.C.C(1:1.5:3) bottom slab including supplying, fitting and fixing all necessry specials, fittings, S.W. tees, C.I. foot rest etc. including excavation earth in all sorts of soil, shoring, bailing out and pumping out water as necessary, ramming, dressing the bed and fefilling the sides of the tanks with earth, removing spoils, filling up the chamber with clear water, removing foreign materials from the chamber and including constructing attached inspection pit as per approved drawing and connecting all necessary pipes, joints etc. with internal plaster work and artificial stone flooring is to be done with admixture of water proofing compound @ 0.5% by weight of cement with all costs of labour and materials. Note:- (i) Finished level of Septic Tank should be 400 mm. from Ground Level. (ii) Height of 50 mm. Ventilation pipe &Mosquito proof mesh, should be follwed as per IS:2470,Part- I.Payment will be made separetly on the basis of actual height based on relevant I.S.Code. (iii) For 30 users A) With Pakur variety. (SAIL/TATA/RINL)
(ii) For 20 users A) With Pakur variety. (SAIL/TATA/RINL)
(iii) For 50 users A) With Pakur variety. (SAIL/TATA/RINL)
Construction of circular soak well 2.5 metre deep in all types of sandy soils with dry brick work upto 1.6 metre from the bottom having 150 mm intermediate cement brick work (1:4) band all round and cement brick work (1:4) upto 0.90 metre from top with 20mm thick cement plastering (1:4) to inside face upto the depth of cement brick work, 15mm thick cement plaster (1:4) on outer face from top of the well upto G.L. and 6 mm thick cement plaster (1:4) on top of the R.C.C. cover slab including filling bottom 1.00 metre of inside of the well with brick metal (50 mm to 63 mm size) including R.C.C. cover slab of 100 mm thick with cement conc (1:1.5:3) with stone chips with necessary reinforcement and shuttering including one 560 mm dia. R.C.C. manhole cover (heavy type)of approved make supplied, fitted and fixed in the cover slab with necessary fittings, making nacessary arrangements for pipe connections, excavation of well including shoring, dewatering and removing the exess earth from the premises as per direction complete in all respect with all costs of labour and materials. With 250 mm thick dry brick work and 250 mm thick cement brick work (1:6) and 1.00m inside dia. (SAIL/TATA/RINL)
A. Compacting original ground supporting subgrade Loosening of the ground upto a level of 300 mm below the subgrade level, watered, graded and compacted in layers to meet requirement of Tables 300.1 and 300.2 for subgrade construction as per Clause 305.3.4 of Specifications for Road & Bridge Works of MoRT&H (5th Revision).
B. By Mix in Place Method :Construction of granular sub-base by providing graded material, mixing by mix in place method with Rotavator at OMC, spreading in uniform layers with Motor grader on prepared surface in proper grade and camber, compacting with vibratory roller to achieve the desired density, including lighting, guarding, barricading, including cost of all materials, machinery, tools and plants including cost of quality control complete as per Clause 401 of Specifications for Road & Bridge Works of MoRT&H (5th Revision). (ii) Grading – II
B. By Mix in Place Method : Construction of granular sub-base by providing graded material, mixing by mix in place method with Rotavator at OMC, spreading in uniform layers with Motor grader on prepared surface in proper grade and camber, compacting with vibratory roller to achieve the desired density, including lighting, guarding, barricading, including cost of all materials, machinery, tools and plants including cost of quality control complete as per Clause 401 of Specifications for Road & Bridge Works of MoRT&H (5th Revision). (iv) Grading – IV
Providing, laying, spreading and compacting stone aggregates of specific sizes to water bound macadam specification including spreading in uniform thickness, hand packing, rolling with vibratory roller 8-10 tonnes in stages to proper grade and camber, applying and brooming requisite type of screening / binding materials to fill up the interstices of coarse aggregate, watering including lighting, guarding, barricading and making necessary earthen bundh of one metre width on each side and preparing the bed by necessary cutting or filling, including cost of all materials and hire and labour charges of all men and machinery and compacting to the required density, as per Clause 404 of Specifications for Road & Bridge Works of MoRT&H (5th Revision). (iii) Grading-II Aggregate (53 mm to 22.4 mm) Using Stone Screening Type B (11.2 mm)
100 mm thick interlocking designer concrete paver block M-50 grade for hightraffic zone, bus terminus, industrial complex, mandi houses etc. as per IS: 15658- 2006 (over 20-40 mm medium sand bed on 250mm thk WBM/ WMM base course & 250 mm thk bound gnaular/ granular sub-base course & filling the interstices of blocks with fine sand by brooming & subsequent watering including cost of sand for sand bed but excluding cost of base, sub-base course & subgrade preparation.) complete as per direction of Engineer-in-Charge. [Note: Subgrade CBR shouldnot be less than 5]
Wet Mix Macadam Base Course Providing, laying, spreading and compacting graded stone aggregate to Wet Mix Macadam specification including screening of aggregates and granular materials, premixing the material with water at OMC in Wet Mix Plant, carriage of mixed material by tipper to site, laying in uniform layers with Paver in Sub- base / Base course on well prepared surface and compacting with Vibratory Roller to achieve the desired density, including supply of all materials, machinery, fuel and lubricants, including incidental costs for lighting, guarding, barricading, making earthen bundh to protect the edges including cost of quality control complete as per Clause 406 of Specifications for Road & Bridge Works of MoRT&H (5th Revision).
Supplying and fixing 415Volt 125A TPN Sheet steel Main Switch on angle iron frame on wall as to GS ( HPL/Haveeis) .[PWD SoR-D-1/1b]
Supplying and fixing 415Volt 125A 4 Al bar Sheet steel(16SWG) cable loop box (450mm x 300mm x 150mm size) on iron frame on wall as to GS.[PWD SoR-D-12/19]
S & F of 500V 100A rewireable Kit-Kat Fuse 3 sets at Meter Room complete with fixing of 25mm thick water proof Plyboard/Hard Wood.
Supply & drawing 1.1KV grade 25 sq mm stranded PVC insulated Copper lead with PVC pipe as meter loop (Make- Havells/KEI/Mescab/Polycab).
Finishing the end termination of 25 sq mm Copper lead with Dowells solderless Cu socket as to GS.[PWD SoR-F-5/9]
Supplying and fixing double door Horizontal 4way TPN MCB Distribution board with IP-42/43 protection, concealed in wall after cutting the wall & mending good the damages to original finish incl. Inter connection with suitable size of copper wire and neutral link & provision for earthing attachment complete with 100A 4pole isolator & 12 nos.32A SP MCB outgoing(Legrand /L & T/ABB make).(PWD SoR-D-5/6, D-6/7, D-10/14)
Supplying and fixing double-door (2+8)way SPN MCB Distribution Board with IP-42/43 protection complete with 1No. 40A DP isolator as incomer, 8 nos 6/10A SP MCB 10kA capacity outgoing, concealed in wall after cutting the wall & mending good the damages to original finish incl. Inter connection with suitable size of copper wire and neutral link & provision for earthing attachment.(Make- Legrand/L & T/ABB) [PWD SoR-D-9, 13,D-5,6,D-6,7]
Supplying and fixing double-door (2+6)way SPN MCB Distribution Board with IP-42/43 protection complete with 1No. 40A DP isolator as incomer, 6 nos 6/10A SP MCB 10kA capacity outgoing--do---do-- (Make- Legrand/L & T/ABB) [PWD SoR-D-9, 13,D-5,6,D-6,7]
Supplying and fixing double-door (2+4)way SPN MCB Distribution Board with IP-42/43 protection complete with 1No. 40A DP isolator as incomer, 4 nos 6/10A SP MCB 10kA capacity outgoing--do---do-- (Make- Legrand/L & T/ABB) [PWD SoR-D-9, 13,D-5,6,D-6,7]
Supply & fixing of Timer Controller for Security light consisting of 1 No.40A DP MCB isolator, 25A 2-Pole Power Contactor(L&T make), 240V 24 hours Digital Timer, Centre off 2-way toggle switch, 32A Barrier type Terminal, 2 nos. LED indicating lamp with suitable size powder coated MS 12 way SPN BD box complete with internal electrical connections by 2x4 + 1x2.5 sqmm CU wires as required.
Supplying and fixing 32A DP MCB C-categories 10kA capacity in existing SS enclosure for compound light at Godown & Office (Make- L & T/Legrand/ABB) [PWD SoR-D-6,7]
Supplying and fixing MCB SS enclosure with IP-20/30 protection, powder coated provision for two pole MCB, connection & provision for earthing attachment [PWD SoR-D-9,11]
Supply of 1.1KV grade 4 core 50 sqmm PVC/XLPE insulated armoured Al cable. (Havells/KEI/Polycab/Gloster make)
Supply of 1.1KV grade 4 core 25 sqmm PVC/XLPE insulated armoured Al cable (Havells/KEI/Polycab/Gloster make)
Supply of 1.1KV grade 4 core 16 sqmm PVC/XLPE insulated armoured Al cable (Havells/KEI/Polycab/Gloster make)
Supply of 1.1KV grade 2 core 10 sqmm PVC/XLPE insulated armoured Al cable (Havells/KEI/Polycab/Gloster make)
Supply of 1.1KV grade 2 core 6 sqmm PVC/XLPE insulated armoured Al cable (Havells/KEI/Polycab/Gloster make)
Laying of cable upto 2 core 25 sqmm on wall/surface incl. S & F MS saddles with earthing attachment in 10 SWG GI (Hot Dip) Wire, making holes etc. as necy. mending good damages and painting [PWD SoR-F-1/2a]
Laying of cable upto 4 core 25 sqmm on wall/surface incl. S & F MS saddles with earthing attachment in 10 SWG GI (Hot Dip) Wire, making holes etc. as necy. mending good damages and painting [PWD SoR-F-1/2b]
Laying of one No. cable upto 35 sqmm in underground trench 460 mm wide x 760 mm average depth, with brick protection on the top of the cable with 8 (eight) Nos. bricks per metre, including filling the space between the brick & cable and also the trench with shifted soil, leveling up and restoring surface duly rammed [PWD SoR-F-2/1a]
Laying of cable from 4 core 35 sqmm to 50 sqmm on wall/surface incl. S & F MS saddles with earthing attachment in 2 x 10 SWG GI (Hot Dip) Wire, making holes etc. as necy., mending good damages and painting[PWD SoR-F-1/2c]
Supplying and fixing compression type gland complete with brass gland, brass ring & rubber ring for dust & moisture-proof entry of XLPE/PVC armoured cables and finishing the end of following XLPE/PVC armoured cables by crimping method incl. supplying and fixing solderless socket (Dowels make), tapes, anticorrosive paste & jointing materials. for 4 core 50 sqmm [PWD SoR-F-4, 7(c) & F-5,8(b)]
Do--do--do-- for 4 core 25 sqmm [PWD SoR-F-4, 7(a) & F-5,8(b)]
Do--do--do-- for 4 core 16 sqmm [PWD SoR-F-4, 7(a) & F-5,8(b)]
Do--do--do-- for 2 core 10 sqmm [PWD SoR-F-4, 7(a) & F-5,8(b)]
Do--do--do-- for 2 core 6 sqmm [PWD SoR-F-4, 7(a) & F-5,8(b)]
Distribution wiring in 1.1 KV single core stranded 'FR' PVC insulated & unsheathed 4 x 6 +2 x4 sq mm copper wire (Brand approved by EIC) in 25mm size PVC rigid conduit 'FR' (Precision make) incl. necy. fittings as required. [PWD SoR E-14/1b(v)].
Distribution wiring in 1.1 KV single core stranded 'FR' PVC insulated & unsheathed 2 x 6 +1 x4 sq mm copper wire (Brand approved by EIC) in 20mm size PVC rigid conduit 'FR' (Precision make) incl. necy. fittings as required.[PWD SoR E-14/1a(iv)].
Distribution wiring in 1.1 KV single core stranded 'FR' PVC insulated & unsheathed 2 x 4 +1 x2.5 sq mm copper wire (Brand approved by EIC) in 20mm size PVC rigid conduit 'FR' (Precision make) incl. necy. fittings as required.[PWD SoR E-14/1a(iii)].
Distribution wiring in 1.1 KV single core stranded 'FR' PVC insulated & unsheathed 2 x 2.5 +1 x1.5 sq mm copper wire (Brand approved by EIC) in 20mm size PVC rigid conduit 'FR' (Precision make) incl. necy. fittings as required.[PWD SoR E-14/1a(ii)].
Distribution wiring in 1.1 KV single core stranded 'FR' PVC insulated & unsheathed 3x1.5 sq mm copper wire (Brand approved by EIC) in 20mm size PVC rigid conduit 'FR' (Precision make) incl. necy. fittings as required.[PWD SoR E-14/1a(i)].
Distn. wiring in 3 x 1.5 sqmm single core stranded 'FR' PVC insulated & unsheathed single core stranded copper wire (Brand approved by EIC) in 19 mm bore, 3 mm thick polythene pipe complete with all accessories embedded in wall to light/fan/call bell points with Piano key type switch (Anchor make) fixed on sheet metal (16 SWG) switch board with bakelite/perspex (wall matching colour) top cover (3 mm thick) flushed in wall incl. mending good damages to original finish Av run 6mtr. [PWD SoR-E-9/2a]
Do----do---do--- to 240 V 5A 3 pin plug point incl. S&F 240 V 5A 3 pin flush type plug socket & piano key type switch (Anchor make) incl. S&F earth continuity wire, fixed on sheet metal (16 SWG) switch board with bakelite/perspex (wall matching colour) top cover (3 mm thick) flushed in wall incl. mending good damages to original finish on board.[PWD SoR-E-10/4a]
Supply & Fixing 240 V, 20A, plug socket with separate 20 A Piano key type switch (Brand approved by EIC) on sheet metal switch board embedded in wall incl. S & F 150x100x65mm MS (16SWG) switch board and bakelite/perspex top cover of 3mm thick by Brass screws after making housing for switch by cutting bakelite/perspex cover and making necessary connections as required.[PWD SoR-E-6/22]
Supply & Fixing 240 V, 3 nos. 6A, & 1 no. 20A plug socket with separate 3 nos. 6 A & 1 no. 20A Piano key type switch, indicator & 20A switch type SP MCB (Brand approved by EIC) on sheet metal switch board embedded in wall incl. S & F 240x200x65mm MS (16SWG) switch board and bakelite/perspex top cover of 3mm thick by Brass screws after making housing for switch by cutting bakelite/perspex cover and making necessary connections as required [PWD SoR-E-7/26]
Distn. wiring in 3 x 1.5 sqmm single core stranded 'FR' PVC insulated & unsheathed single core stranded copper wire (Brand approved by EIC) in 19 mm bore, 3 mm thick polythene pipe complete with all accessories embedded in wall to light/fan/call bell points with Modular type switch (Brand approved by EIC) fixed on Modular GI switch board with top cover plate flushed in wall incl. mending good damages to original finish. Av run 8 mtr. [PWD SoR-E-20/1]
Do---do---do---to 240 V 6A 5 pin plug point incl. S&F 240 V 6A 3 pin Modular type plug socket & Modular type switch (Brand approved by EIC) incl. S&F earth continuity wire, fixed on 4 Module GI switch board with 3/4 Module top cover plate flushed in wall incl. mending good damages to original finish on board [PWD SoR-E-20/3]
Supply & Fixing 240 V, 16 A, 3 pin Modular type plug socket (Brand approved by EIC) with 16A Modular type switch, without plug top on 4 Module GI Modular type switch board with top cover plate flushed in wall incl. S&F switch board and cover plate and making necy. connections with PVC Cu wire and earth continuity wire etc.[PWD SoR-E-18/9b]
Supply & Fixing 240 V, 3 nos. 16 A, 3 pin Modular type plug socket with 3 nos. 16A Modular type switch (Brand approved by EIC), 20A Modular switch type SP MCB (C-Curve) and Indicator without plug top on 2 row 12 Module GI Modular type switch board with 2 row 12 Module top cover plate flushed in wall incl. S&F switch board and cover plate and making necy. connections with PVC Cu wire and earth continuity wire etc.[PWD SoR-E-18/13]
Supply & Fixing 240 V, 25 A, Modular type starter (Brand approved by EIC) with 25A Modular switch type DP MCB (CCurve) and 4 Module GI Modular type switch board with 4 Module top cover plate flushed in wall incl. S&F switch board and cover plate and making necy. connections with PVC Cu wire and earth continuity wire etc.[PWD SoR-E-19/17]
Supply & Fixing 240 V, 25 A, 3 pin Modular type plug socket (Brand approved by EIC), without plug top and switch, on existing GI Modular type switch board with top cover plate and making necy. connections with PVC Cu wire and earth continuity wire etc.[PWD SoR-E-17/4c]
Supply & Fixing 240 V,25 A, 3 pin Modular type plug top with indicator (Brand approved by EIC) & necy. Connections.[PWD SoR-E-17/5b]
Supply & Fixing Socket type fan regulator (Step type) (Brand approved by EIC) on existing sheet metal switch board with bakelite/perspex top cover by screw after making housing for regulator knob by cutting bakelite/perspex top cover incl. making necy. connections etc. [PWD SoR-E-6/18]
Supply & Fixing 240V, Modular Socket (2 Module) type fan regulator (Step type) (Brand approved by EIC) on existing Modular GI switch board with top cover plate incl. making necy. connections etc.[PWD SoR-E-18/10]
Supplying & Fixing 240 V AC/DC superior type Ding-Dong Call Bell (Anchor) on HW board incl. S&F HW board [PWD SoR-D-13/20a]
Supply of 240V 20W single LED tube fitting complete with 20W TLED Mas LED T8 lamp(Make: Philips, TMC-501P 1 xT-LED or equivalent Crompton make).
Fixing only single LED tube light fitting suspended 25 cm bellow the ceiling with 2 No. 20 mm dia EI conduit (14 SWG) supports fixed with “L” type MS clamp whose one side fixed on ceiling with sutable size 4 nos. fastener and other side connected with the conduit with suitable size of bolts and nuts incl. S&F EI conduit, “L” type (125mmx125mm) 6mm thick and 25mm with MS clamps and connecting the length of PVC insulated wire and mending good damages to original finish and painting etc. by 2x24/0.20 mm (1.5sqmm.) flexible copper wire of 1.10 mt. length.[PWD SoR-C-2/17]
Fixing only single LED tube light fitting complete with all accessories directly on wall/iron truss and suitable size of MS fastener/clamps. [PWD SoR-C-2/14b]
Supplying & Fixing CRC sheet metal (16 SWG) JB-cum- Switch Board of size 200 mm x 150 mm x 65 mm complete with three no. suitable size Copper bar with holes (for Ph, N & E) fixed on bakelite/Hard Rubber insulator over the MS welded chairs incl. bakelite top cover 3 mm thick flushed in wall for housing the board after cutting the brick wall incl. making earthing attachment, painting and mending good damages to building works[PWD SoR-E-3-4/10c]
S & F 240V 16A Piano Key type switch in existing switch board[PWD SoR-E-5/14b]
Supplying & Fixing sheet metal inspection box (16 SWG) of the following size flushed in wall by housing the same after cutting brick wall incl. making earthing attachment, painting and mending good damages to building works 150 mm x 100 mm x 65 mm [PWD SoR-E-4/11]
Supply & Fixing Bakelite / Perspex top cover on existing Inspection board by Brass screws 150 mm x 100 mm x 65 mm [PWD SoR-E-4/12]
Supplying & Fixing MS fan clamp of two piece type for RC ceiling as per approved specification, fabricated from 40 mm x 9 mm MS flat including making good damages to building roof with satisfactory finishing and painting – (As per Drawing no. 475 of PWD Specification Book – May 1991).[PWD SoR-D-14/29]
Supply of 1200mm sweep AC ceiling fan (Orient NEWBREEZE/Crompton Aura l2OOmm /Havells Equiv.).
Fixing only ceiling fan complete with blades, canopy, fork, rubber bush etc. incl. S&F connecting wire for down rod upto 30 cm incl. painting the rod with approved paint and making necessary connection as required by 2x1.5 sqmm flexible copper wire.[PWD SoR-C-3/21a]
Supply of 300mm sweep heavy duty (1400 RPM) AC exhaust fan (EPC make)
Fixing only 300mm sweep exhaust fan after making hole in wall and making good damages and smooth cement finish etc. as practicable as possible and providing necy. length of PVC insulated wire and making connection for 300 mm sweep exhaust fan.[PWD SoR-C-4,28(b)]
Supply & Fixing louver shutter on wall with necy. bolts & nuts (6 mm dia x 62 mm long)[PWD SoR-D-14/32a]
Supply & fixing of 250V 18W LED lBC lamp (Philips/Crompton).
Supply & fixing decorative 40W Post top for 360° indirect light with IP 65 protection. Resistant to impact and corrosion. Glare-free and better uniformity including necessary fixing arrangement.(Make -Crompton, Maple,Cat No. LTPO 40 CDL-M).
Supply of 70W outdoor LED street light fitting complete with all accessories made up of pressure die cast aluminium housing with toughened glass with IP66 protection & 10KV SPD for security light . (Make: Crompton, Cat No.CRP-411-90-57-SL-GL-NSG/Equivalent Philips/Bajaj/Wipro make )
Supply of 70W outdoor LED street light fitting complete with all accessories made up of pressure die cast aluminium housing with toughened glass with IP66 protection & 10KV SPD for security light . (Make: Crompton, Cat No.CRP-409-70-57-SL-GL-NSG/Equivalent Philips/Bajaj/Wipro make )
Fixing only outdoor / street light fitting complete with all accessories to be fixed /projected from the wall of the building incl. making holes/providing clamping arrangement & necy. GI reducer as required. S&F 40 mm GI pipe (ISI-Medium) quality 1.5 mts. average length having suitable bend S&F necy. length of 1.5 sqmm PVC insulated single core stranded annealed copper wire and making connections as required and mending good damages to wall incl. painting etc.[PWD SoR-C-3/18]
Fixing only outdoor / street light fitting complete with all accessories to be fixedon 9mtr long pole arm bracket S&F necy. length of 1.5 sqmm PVC insulated single core stranded annealed copper wire from loop box at base and making connections as required.
Supplying & installation of 80mm dia 2mt. long GI pole with 6mm thickness MS base plate including 32/40mm dia 1.5mt long GI arm bracket (ISI, medium gauge)complete with pole header & painting & incl. 2x1.5 sqmm FR PVC Cu connecting wire from loop box as per instruction of the EIC for office/weigh bridge/security post.
Providing CC (6:3:1) base block (around the pole) dimension 0.60x0.60x0.76 mt. above ground level, neatly cemented finish (3 mm thick), at the base pole (in lieu of CC muffing) incl. drilled hole in pole suitable for alkathene/polythene pipe entry, for street light wiring, [PWD SoR-H-1/3b(i)]
Supplying and Fixing PVC water proof looping cable box having hinged door of size: 250mm x 200mm x105mm (Sintex make or appd. make) Comprising of 32A capacity 2-way stud type cable terminal & 1 no. 6A SP MCB C-curve,10KA and housing the same on wall by clamping arrangements.
Supply & delivery of 8mtr. long Hot Dip G.I. octagonal pole complete with including cable loop-in loop-out arrangement inside the pole with 6A SPMCB for controlling light fitting, 1mtr. long arm bracket, template, erection nut-bolt etc. (Make-Transrail/Bajaj/Subham).
Erection of octagonal pole of length 8mtr. in CC foundation (Proportion and dimension indicated below), having 600x600x150 mm thick CC (4:2:1) base block below sole plate/pole with hard jhama metal including CC (6:3:1) muffing 0.30 mts. dia and 0.30 mts. above ground level including 3 mm thick neat cemented finish. [PWD SoR-H-1/1]
a) Supply of 20Mtr long High Mast lighting system with its all accessories. Mast shaft shall be in two sections with steel material confirming to BSEN 10025 grade S355 , hot dip galvanised confirming to BSEN ISO 1461 and suitable for wind velocity as per IS 875. It shall also include accessories for 'high mast including head frame, steel wire rope 6 mm dia (7/19 construction), trailing cable, double drum winch, Galvanised Lantern carriage arrangement suitable for 8-12 luminaires 'symmetrically & its control gear boxes and lightning finial. The mast shall have an integral power tool motor installed inside the base compartment for its operation. (Make:Crompton/Transrail/Bajaj)---1 Set b) Supply of foundation bolts manufactured from special steel along with nuts, washers, anchor plates and templates-----1 Set c) Supply of 250W LED floodlight luminaire >110 Lumen/Watt, Potted Driver & 10KV SPD with IP66 protection(Make- Crompton,Cat No. CFS-506-250-57-60D-SL-GL-NSG >110 or euivalent Philips make)---8 Nos. d) Supply of LED aviation obstruction lights GLN-703(Appd. make)---1 Set e) Supply of control panel housing 63 A TPN MCB incomer, double dial timer contactor circuit for the automatic control of luminaries, outgoing terminals and control circuit for the power tool motor with 50% luminarires switching on & off provision---1 Set f) Design, casting of suitable R.C.C foundation with M-20 grade concrete considering SBC of soil as 10 T / Sq. Mtr.( after cuuting of concret & bitumius road---1 Item g) Erection of 20 mtr. High Mast with modern engineering practices---1 Set h) Pipe earthing with 50mm dia GI pipe & 3mtr long. The connections sahll be made with 25X3mm GI strip. ( 2 nos. earthing per mast is required )---2 Set i) Erection , testing & commissioning of the High Mast & feeder pillar box--1 Set
S & F Lightning conductor Air-terminals made of 15 mm dia 1500 mm long GI pipe (ISI Medium) having five prongs of 4 SWG GI (Hot Dip) wire at top with 85 mm dia 6 mm thick GI base plate at bottom incl. necessary holes etc. duly grouted on the parapet etc. in CC mortar (4:2:1) [PWD SoR-J-1/1]
Hiring charges for scaffolding arrangement including dismantling at the end of work and carriage, for LC installation.
Supply & fixing GI (Hot Dip) strips 20 mm x 3 mm thick for horizontal run on the Parapet/Roof/ Wall with GI Saddles 1100 mm apart incl. mending good the damages to building works. [PWD SoR-J-1/9]
Supply & fixing of GI (Hot Dip) strips 20 mm x 3 mm thick for vertical run on wall with GI saddles spaced not exceeding 1000 mm apart incl. mending good damages to building work.[PWD SoR-J-1/11a]
Supply & Fixing of Testing Joints by 20 mm x 3 mm thick GI (Hot Dip) strip 125 mm long grouted on wall having clearance of 6 mm from wall for making connection with thimbles at the end of 7/10 SWG GI (Hot Dip) stranded Wire and 4 SWG GI (Hot Dip) wire of vertical conductor and conductor from earth electrode complete with S & F thimbles, GI bolts, nuts, check-nuts, spring washers etc. as required. [PWD SoR-J-2/13].
Earthing with 50 mm dia GI pipe (ISI medium gauge) 3.64 mm thick x 3.04 Mts. long and 1 x 4 SWG GI (Hot Dip) wire (4 Mts. long), 13 mm dia x 80 mm long GI bolts, double nuts, double washers incl. S & F 15 mm dia GI pipe protection (1 Mts. long) to be filled with bitumen partly under the ground level and partly above ground level driven to an average depth of 3.65 Mts. below the ground level in soft soil including excavation of 1cu.mtr. soil[PWD SoR-G-1]
Earthing by 1.8mtr long 25mm dia GI including connecting the GI octagonal pole with 4SWG GI wire protected by 13mm dia polythene pipe.
Extra for providing masonery enclosure on the top of the earth electrode of overall size 86.36 cm x 86.36 cm x 46 cm deep (below Ground level) complete with cemented brick work(1:6) of 25 cm width duly plastered with cement morter (inside) CI hinged inspection cover of size 36.56 cm x 35.56 cm with locking arrangement, GI reducer including drilling of 46 nos. 12 mm dia holes on the GI pipe [PWD SoR-G-2/3a]
Supplying & fixing earth busbar of galvanized (Hot Dip) MS flat 40 mm x 6 mm on wall having clearance of 6 mm from wall including providing drilled holes on the busbar complete with GI bolts, nuts, washers, spacing insulators etc. as required [PWD SoR-G-2/4b]
Connecting the equipments body to earth busbar including S&F 20 mm x 3 mm galvanised (Hot Dip) MS flat on wall/floor with GI saddles as required and connection to equipments incl. drilling holes, with bolts, nuts, washers etc. [PWD SoR-G-3/5c]
Connecting the earth busbar from the earth electrode by 1.1KV grade single core 25sqmm unarmoured PVC insulated & sheathed cable(Polycab/Havells/Gloster make).
Supplying & fixing medium gauge 80mm dia GI Pipe ( ISI-Medium) Protection with necessary fittings and jointing metarials as required. [PWD SoR-F-6/11]
Supplying & fixing medium gauge 50mm dia GI Pipe ( ISI-Medium) Protection with necessary fittings and jointing metarials as required. [PWD SoR-F-6/11]
Supply,Installation,Testing & Commissioning of 45KVA Silent type Diesel Generator Set complete with suitable size Acoustic enclosure Diesel Engine suitable for Generator application developing 1500 RPM with an overloading capacity of 10% for one hour in any 12 continuous hours operation generally confirms to BS 5514, 3 Phase 4 wires,50 cycles per second self excited self regulated with brushless excitation, Alternator generally confirms to BS 5000 IS 4722, DG set shall be complete with radiator, residential type silencer, electronic governor, cable termination box, MS mounting frame, fuel piping, diesel tank, 24V DC Battery mounting frame etc. including AMF panel (CPCB IV STANDARD DG SET).
Supply and providing exhaust piping complete with fibre glass insulation with aluminium cladding, pipe accessories like flanges, bends, elbows, rain protection hoods etc. The exhaust piping shall be fixed from floor with MS angle supports, using necessary clamps, anchor bolts etc. suitable for 45 KVA DG Set.Exhaust pipe 150mm dia 5mm thick MS with necessary fittings.
Mineral wool/glass wool lagging for exhaust pipe system including aluminium cladding for above pipe(200mm dia).
Supply and erection of Exhaust pipe supporting systemwith ISMC, ISA complete including Red Oxide and black enamel painting etc.
Please Enable Macros to View BoQ information
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 1.00 MB
BOQ_2386960.xls
BOQ • 0.74 MB
2911ii.pdf
Tender Documents • 0.50 MB
Annexure-II.pdf
Tender Documents • 1.43 MB
Download all tender documents and submit your bid