Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹20.3 LAccepted-AOC G 16 JAY COMPLEX BELOW UMA CO OP BANK NIZAMPURA VADODARA GUJARAT 390002 | VADODARA | VADODARA | GUJARAT | 390002 | ₹20.3 L Quoted ₹21.1 L | L1 | Accepted-AOC Being L1 |
| 2 | L2₹22.1 L+₹95,316.25 (4.51%)Rejected-AOC | ₹22.1 L+₹95,316.25 (4.51%) | L2 | Rejected-AOC Being not L1 |
| 3 | L3₹22.1 L+₹1.0 L (4.77%)Rejected-AOC 4 A RUKSHMANI PARK SOCIETY OPP SAMA WATER TANK NEW SAMA ROAD VADODARA 390 008 | VADODARA | VADODARA | GUJARAT | 390008 | ₹22.1 L+₹1.0 L (4.77%) | L3 | Rejected-AOC Being not L1 |
| 4 | L4₹23.2 L+₹2.1 L (9.95%)Rejected-AOC 13 THAKKAR PLOT DEEPAK KUNJ PORBANDAR 360575 | PORBANDAR | GUJARAT | 360575 | ₹23.2 L+₹2.1 L (9.95%) | L4 | Rejected-AOC Being not L1 |
| 5 | L5₹25.0 L+₹3.9 L (18.6%)Rejected-AOC ARIHANT 15 A GOKUL SOCIETY SINDHWAL MATA ROAD PRATAPNAGAR VADODARA 390 004 | VADODARA | GUJARAT | 390004 | ₹25.0 L+₹3.9 L (18.6%) | L5 | Rejected-AOC Being not L1 |
Tender Value
Refer Docs
EMD Value
₹40,000
Closing Date
9 Mar 2021, 6:00 pmClosed
GE Army Baroda
Opp Akashwani, Makarpura road PO-ONGC Baroda-390009
As per BOQ
2021_MES_421850_1
8572
Open Tender
Civil Works
Item Rate
180 days
GE Army Baroda
As per tender documents
5 documents required · 5 mandatory
₹500
Yes
GE Army Baroda
₹40,000
Yes
30 Mar 2021
13 Feb 2021
11 Mar 2021
15 Feb 2021
9 Mar 2021
24 Feb 2021
17 Feb 2021 - 19 Feb 2021
Amount
Excavation in trenches not exc 1.5m wide & not exc 1.5m in depth for foundation for laying of Cable / CI /GI pipe line in trenches not exc 10sqm on plan & not exc 1.5m in depth & getting out in soft / loose soil complete.
Returning, filling in trenches including spreading, leveling watering and well ramming in layers not exceeding 25cm in soft/loose soil complete.
Removing excavated material to a distance not exc 50mtr and depositing where directed at level n exc1.5 mtr above the starting point complete.
Taking up CI/DI/GI water mains ( including aii fittings) with spigot & socketed ends from trenches including burning of lead joint, removing of lead for following bore of pipe complete of following size :
150 mm bore
80mm bore GI Pipe Line
50 mm bore GI Pipe Line
Supplying, laying, jointing & testing 150 mm bore dia ductle iron pipes with spigot and socket ends suitable for tyton joint centrifugally cast class – K 7 (IS-8329 Marked) in any length complete.
S&F to wall/trenches GI steel tubing medium grade including all fittings such as Tees, elbow, bends etc for following bore of pipe complete.
80 mm bore
50 mm bore
S&F in replacement 150 mm bore dia sluice valve cast iron both ends flanged class PN – 1 conforming to IS-14846 with SS spindle & wheel including jointing materials Rubber gasket, Nut Bolt and Washer etc. Complete. Make: Kartar/Zoloto/ Upadaya
S&F bends, tapers,Tee pieces ( single or double branch ) any type and angle or radious & straight connecting pieces but all ends flanged up to 150 mm bore.
Cutting 150 mm bore dia CI pipes and reducing to required length in position for insertion of tees, sluice valve, branches etc complete.
M&L in replacement brick masonary valve pit of size 1200 x 1200 x 900 mm (internal dimension) with MS angle iron frame work (Angle Iron size 50 mm x 50 mm x 6 mm) & 3.20 mm MS sheet top cover openable through hinges including necessary locking arrangement, rendering 10mm thk in CM 1:3 and painting with two coat of black bituminous paint over a one coat red oxide primer complete.
M&L for 125mm dia bore well with PVC casing pipe including sloted pipe, gravel packing and GI clamps complete. Make : Finolex, Supreme or equivalent.
M&L Cleaning / Development of borewell by using air compressor of capacity 6000 CFM or more at a pressure of 4 Kg/cm2 or more, till the time clear water (free from sand / dust / suspended solids) comes out of the bore well complete.
S&F UPVC / HDPE column pipe 40 mm dia heavy duty duly threaded both side and one heavy duty socket one end. Column pipe must be made of length 3 mtr each complete. Make : Finolex, Supreme or equivalent.
M&L S.I.T.C of Stainless steel body submersible pump of capacity 2 HP complete. Make KSB or equivalent.
M&L flat submersible cable of size 6 sqmm for connection of pump to starter including making water pump connections etc complete. Make : Polycab / Havells / Finolex
S&F DOL Starter complete of 2 HP capacity complete. Make BCH, L&T, ABB
S&F LED 72 Watt Street Light with New generation energy saving and environmental friendly long life LED street light made up of pressure die cast aluminium housing with high power LED as lighting source and lens embedded PC cover having TOP OPENING seperate driver compartment with IP66 protection and impact resistance of IK07 with 10KV Built-in Surge Protection Device as per HLSLD-ML04-72-CWL Make Halonix or its equivalent in Phillips/ Wipro/Jaquar/Havells. Note: Quoted rate shall includes the price of 40/50 mm bore light grade GI pipe fixed as bracket, on Pole any type, not less than 1.0 m long and bent to shape as required complete with sutiable clamp made out of 25x4mm Flat iron duly fixed 12mm dia nuts, bolts, washers etc.suitable for steel tubular / PCC pole complete.
S&F three phase PVC Jnction Box of Size 30 cm x 20 cm x 10.5 cm with hinged door inculding locked arrangment with MCB SPN 10 Amps 1 No including necessary clamping. Nuts, bolt etc complete
S&F 2.5 sqmm alongwith earth wire with insulated copper conductor, single core cable in run through pole for street light as required with 2 X 2.5 sqmm + 1 X 2.5 sqmm earth wire complete.
M&L for Air termination, single pointed, copper rod 12mm dia and 300mm long complete.
M&L for Copper strip 20 x 3.15mm with saddles and fixing screws etc. for roof conductors and down conductors above ground complete
M&L for Test point terminal block made of gun metal or phosphorus bronze size 75x75x25mm drilled and screwed including 3 nos. 8mm dia 25mm long hex. Head screw complete.
M&L for Copper strip 32 x 6mm buried in ground
M&L for GI Tubes, of size 40mm dia medium grade, galvanised, with fitting for protection of Air Termination rod including GI nuts,bolts and clamps sutable size for protection of Aluminium Strip complete.
M&L for Demolition of road/path /concrete in ground floors and pavings n exc 15 cm thickness (below or above ground level) complete.
M&L for cement concrete type B-2, 1:2:4 (40mm graded aggregate) 150mm thick complete.
M&L in replacement Earthing with opper plate 60 × 60cm × 3.15mm thick buried directly in ground, (Earth pit not less than 2.25 meter deep below ground level) with top edge of plate not less than 1.5 meter below normal ground level, connected to and including 20×3mm copper strip as earthing lead by means of nut, bolts, check nuts and washers of galvanised iron or steel complete all as specified and directed including testing on completion including the following : - (a) Excavation and earth work for drilling hole for electrode in any type of Soil. (b) PCC pit in cement concrete 1:2:4 type B-1, Pre cast RCC cover with suitable handle 40 mm thick in PCC 1:2:4 type B-1, reinforced with welded steel wire fabric weighing not less than1.87 Kg/ Sq meter. (c) Funnel with watering pipe of GI 20 mm nominal bore light grade and lugs etc complete. (d) 40 mm nominal bore medium grade GI protection pipe 5 meter long for protection of earthing lead complete. (e) Requisite quantity of common salt and charcoal. (f) Testing of earthing. NOTE :- On testing after completion of earthing, if the desired earth resistance is not obtained, the earthing will be re-done by the contractor at his own risk and cost to the entire satisfaction.
M&L for sand cushioning to PVC cable with using clean dry and natural river sand gently punning below/around cable complete.
M&L well burnt bricks sub class 'B' as in protection of cable laid dry, flat abutting each other width wise complete.
Supply and Laying only including jointing and testing only electric under ground LT cable PVC / XLPE insulated armoured aluminium conductor cable 1100 volts grade in trenches ducts, pipe on walls, poles complete of following sizes
25 sq mm 3.5 core
16 sq mm 4 core
10 sq mm 2 core
Supply, installing, testing and commissioning in replacement factory made LT Panel double door, outdoor type, fabricated of Size 1mtrx1mtrx0.40mtr not less than 3.0 mm thick MS sheet, openable from rear both with 40X40X6 mm angle iron frame at base 30 cm long legs grouted in pillars of PCC 1:2:4 type B1 using 20mm stone aggregate with clearence of 90 cm from ground level and locking arrangement powder coated finish over a coat of red oxide primer on outside and two coats of red oxide primer on inside surface and comprising of following including Excavation/Earthwork/PCC complete. (a) MCCB 4 pole 125 Amps, 16 KA -01 No. (b) Bus bar - 04 Nos (Three for Phase and One for Neutral) made of copper mount on FRP Moulded epoxy insulator with inter connection using copper cable of cap 200 Amps. (c) MCB 63 Amp 4 pole - 01 NO. (d) MCB 40 Amp 4 Pole - 01 No. (e) MCB 40 Amp 2 Pole - 04 No. (f) PVC insulated overall PVC sheathed 2.5 sqmm 2 core copper conductor cable from MCB to Motor - 10 RM. (g) Cable gland/rubber bush as applicable to check the entry to foreign inspects etc. (h) Internal wiring with PVC insulated multistranded copper conductor cable, 1100 V grade, IS 694 marked of appropriate size but not less than 0.5 sqmm. (j) Internal wiring with PVC insulated multistranded copper conductor cable, 1100 V grade, IS 694 marked of appropriate size but not less than 0.5 sqmm. (k) Digital voltmeter & Ammeter with necessary CTs. (l) LED lamp R, Y, B indication.
S&F air cooled split type unit indoor/ outdoor air conditioner with copper condenser coil with cordless remote control unit and electric driven, single phase of capacity of 1.5 Ton, BEE 3.2 (ISEER Value), 3 star rated, 2021 model with in built air ioniser, Plasma filter, 2 way auto swing, Turbo cool, Auto restart with memory, Anti corrosive copper fins, self clean technology, I feel in built sensor, Noise level below 45 db, R32 refrigerant Gas including PVC drain pipe, Bracket for outdoor unit, core drilling, white cement, vinyl tape & covered 10ft copper pipe etc. complete. Make VOLTAS, LG, BLUE STAR
S&F Voltage stabilizer for automatic operation, single phase naturally air cooled indoor type & designed for input variation between 170 V to 250 V with output voltage stabilized at 230 V with accuracy of ± 2.5% and of capacity 4.0 KVA Suitable for 1.5 Ton AC with digital display with Inteligent time delay system, built in thermal overload protection, low & high voltage cutoff, built to last, Micro controler inside, egergy saving technology and wall mount metallic body etc. complete. Make VWI 400 of V Gaurd or equivalent in Microtek, Vintec
S&F sheet metal enclosures with socket plug top, and MCBs single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB upto 20 Amps, 240 Volt capacity
M&L for Sub main wiring with FRLS two single core PVC insulated and unsheathed fire retardant multi stranded copper conductor cable 1100 volt grade IS-694, marked of 4.0 Sqmm size drawn through and including not less than 25 mm dia PVC conduit medium grade ISI marked and conduit junction boxes, terminal boxes and accessories such as tees, bends, elbows, reducers, bell mouth tube ends fixed to the surface of wall/ceiling including one run of 4.0 sqmm PVC insulated and unsheathed FRLS multi stranded copper conductor cable for earth wire continuity conductor complete.
Shiv Projects
Gayatri Associates
OM Engineering
Dagli Engineers
CENTAUR ENGINEERS
RAJENDRASINH B THAKOR
Pratik Enterprise
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .