Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹9.9 LAccepted-AOC | L1 | Accepted-AOC Accepted | |
| 2 | L2₹12.5 L+₹1.7 L (16.3%)Rejected-AOC KALIBARI BAZAR TUPKHANA PART I PO ARUNACHAL P S SILCHAR DISTT CACHAR ASSAM 788 025 | SILCHAR | CACHAR | ASSAM | 788025 | L2 | Rejected-AOC Rejected | |
| 3 | L3₹12.6 L+₹1.9 L (17.5%)Rejected-AOC | L3 | Rejected-AOC Rejected |
Tender Value
Refer Docs
EMD Value
₹20,000
Closing Date
10 Dec 2020, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GARRISON ENGINEER SILCHAR
GE SILCHAR, PO-ARUNACHAL, DIST-CACHAR, ASSAM-788025
REPAIRS TO FAN, METER AND GEYSER AT MASIMPUR MILITARY STATION UNDER GE SILCHAR
2020_MES_392966_1
8593/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
MASIMPUR
Please refer Tender documents.
7 documents required · 7 mandatory
₹500
GE SILCHAR
₹20,000
Yes
2 Jan 2021
5 Nov 2020
11 Dec 2020
5 Nov 2020
10 Dec 2020
25 Nov 2020
60 days
Amount
Taking down carefully 1200/1400mm sweep ceiling fan of any make from the hook and carry to the wksp including rehanging after repair the same at existing position after cleaning dirt, greasing of fan complete all as specified and directed by Engr-in-Charge . NOTE :- Total service time from taking down to rehanging must not exceed 3 Days.
Painting of ceiling fans 1200/1400 mm sweep complete with white synthetic enamel paint by spray painting to achieve a smooth and uniform finish (one coat) after cleaning and filling up cavaties with filler and marking MES No with black paint of required size complete all as specified and directed Note :- Painting of fans must be done before delivery of fan by contractor to Deptt within stipulated time of 3 Days
Strip opening of ceiling fan 1200 sweep and carrying out rewinding with proper grade/guage super enamelled copper winding wire ( approximate weight of winding wire 275 -325 gms /fan ) so as to achieve original specifications i.e current rating and RPM including all insulating materials,bushes etc re-assembling including testing for continious 2 hrs complete all as specified and directed Note :-1. RPM test of ceiling fan with suitable tachometer will be done in the presence of Engineer -in -Charge. 2. All T & P will be provided by the contractor with in the rates quoted for the item.
All as per srl item No.3 above but ceiling fan of 1400mm sweep ( approximate weight of winding wire 300 -350 gms /fan ). Note :-1. RPM test of ceiling fan with suitable tachometer will be done in the presence of Engineer -in -Charge. 2. All T & P will be provided by the contractor with in the rates quoted for the item.
Supply & fixing ball bearings suitable for ceiling fans of size 6201 complete all as specified and directed by Engr-in-Charge complete. Make: SKF or technocommerically equivalent make of NBC/URB.
All as per srl item No 5 but of size 6202 complete Make: SKF or technocommerically equivalent make of NBC/URB.
All as per srl item No 5 but of size 6203 complete. Make: SKF or technocommerically equivalent make of NBC/URB.
All as per srl item No 5 but of size 6204 complete Make: SKF or technocommerically equivalent make of NBC/URB.
Taking out existing worn out /defective gun metal bush and material & labour for new gun-metal bush to the ceiling fans of any size/make incl reassembling and testing etc complete all as specified and directed
Taking out existing defective/worn out condenser any size/make and material and labour for condensor of capacity 2.5 mfd ,220 Volts including making connections etc complete all as specified and directed by Engr-in-Charge Make: USHA or technocommerically equivalent of make BAJAJ/HAVELLS.
All as per srl item No.10 here-in-before but of capacity 3.15 mfd capacity Make: USHA or technocommerically equivalent of make BAJAJ/HAVELLS.
All as per srl item No.10 here-in-before but size 4 mfd, Make: USHA or technocommerically equivalent of make BAJAJ/HAVELLS.
Taking out defective fan regulator any type and make and supply & fix electronic step type fan regulator 5 stage speed variation ISI marked including making connection etc and cutting to the required size of 3 mm thick bakelite sheet where required complete all as specified and directed Make :Havells or technocommerically equivalent of make Cona/ Plaza.
Taking out worn out/cracked canopy and supply & fixing canopy with screws to the ceiling fans of any size/make etc complete. (Set of 2 pieces)
Supply and fixing plastic bottom cover of ceiling fans any size complete with and including all fixing arrangements complete all as specified and directed.
Taking down carefully exhaust fan 225mm to 450mm sweep from the existing location having any make including re-fixing the same after repair in existing position after cleaning and greasing complete all as directed by Engr-in-Charge. Note :- 1. Total service time from taking down to rehanging must not exceed 3 Days.
Painting to exhaust fans/bracket fans/wall mounting fans/pedestal fans up to 300 mm sweep of any make with one coat of synthetic enamel smoke grey paint by spray painting to achieve smooth and uniform finish incl removal of existing paint, filling up cavities with filler complete all as specified and directed by Engr-in-Charge . Note :- 1.Painting of fans must be done before delivery of fan by contractor to Deptt within stipulated time of 3 Days 2. All T & P will be provided by the contractor with in the rates quoted for the item.
All as per ser item No 17 above but of size 375 mm to 450 mm sweep.
Material and labour for re-winding of exhaust fan/bracket fans/wall mounting fans/pedestal fans 225mm to 300 mm sweep after strip opening of motor with proper grade/guage of super enamelled copper winding wire (approximate weight of winding wire 250 -300 gms /fan ) so as to achieve original specifications i.e current rating and RPM including all insulating materials, bushes etc re-assembling including testing for continious 2 hrs complete all as specified and directed Note :-1. RPM test of ceiling fan with suitable tachometer will be done in the presence of Engineer -in -Charge. 2. All T & P will be provided by the contractor with in the rates quoted for the item.
Material and labour for re-winding of exhaust fan/bracket fans/wall mounting fans/pedestal fans 375mm to 450mm sweep after strip opening of motor with proper grade/guage of super enamelled copper winding wire ( approximate weight of winding wire 275 -325 gms /fan ) so as to achieve original specifications i.e current rating and RPM including all insulating materials,bushes etc re-assembling including testing for continious 2 hrs complete all as specified and directed Note :-1. RPM test of ceiling fan with suitable tachometer will be done in the presence of Engineer -in -Charge. 2. All T & P will be provided by the contractor with in the rates quoted for the item.
Taking down worn out/defective metalic blades of exhaust fan/wall mounting/ padestal fan off size 225mm to 300mm sweep and supply and fixing new blades as per sample and make to the exhaust fan refixing in existing position etc complete all as specified and directed.
All as per srl No 21 but of size 375 mm to 450 mm sweep.
Supply and fix in repairs heating element for following rating as required at site including rubber washers (ISI marked), Triangular/round shape with pocket for thermostat:-
1.5 KW rating
2.0 KW rating
Supply and fix in repairs thermostat ISI marked suitable for the geysers 25 ltrs to 50 lts capacity, 20 Amps, 240 volts AC, adjustable type, 210 mm long or nearest size as per sample
Supply and fix in repairs thermostat ISI marked suitable for the geysers 25 ltrs to 50 lts capacity, 20 Amps, 240 volts AC, fixed type, 300 mm long or nearest size, set at 90+/-6 degree as per sample.
Taking down electric water heater (geyser) of any capacity from existing system, disconnect inlet and outlet water connection for leakage complaint and repair to water inner tank by means of brazing/welding etc. to arrest the leak and refixing the inner tank in outer shell with proper filling of glass wool as heat resistance material in suitable quantity, and refixing the geyser at it's original location and connecting with the water distribution system complete all as specified and directed.
Taking down electric water heater (geyser) of any capacity from existing system, disconnect inlet and outlet water connection for leakage complaint and replacing the rusted, leakage inner water tank with new one made out of steel of following capacity and refixing the inner tank in outer shell with proper filling of glass wool as heat resisitance material in suitable quantity and refixing the geyser at it's original location and connecting with the water distribution system complete all as specified and directed.
Inner water tank of capacity 25 ltrs
Inner water tank of capacity 50 ltrs
Supply and fix in repairs indicators of geysers 25 to 50 ltrs capacity
Supply and fix in repair cable PVC insulated 3 core 2.5 sqmm with stranded copper conductor 1100V grade from socket/switch to geyser
M&L for painting to external surface of geyser of any capacity in one coat of synthetic enamel paint, after removing of all loose paints, rust, dust and all oily particle by washing and making suitable for painting and incl writing MES No with black synthetic enamel paint complete all as specified and directed.
Supply and fix 3 pin plug top, 15 Amp capacity, 240 VAC, heavy duty, ISI marked
M&L for apparatus plate suitable for 25/35/50 ltrs geyser all as per sample
Supply and fix clamp of apparatus plate suitable for geyser as per sample
Supply and fix in replacement of Havell's make ELCB with 1.5 mtr long 3 core cable suitable for Havells geysers (Model Puro Turbo) of 25 ltrs cap .
Supply and fix in replacement flexi connection pipe (Hot & Cold) accessory 450mm long with nuts.
Supply and fix as in repairs starting capacitor 4/6/8 MFD as per site requirement for Deep freezer of Capacity 200/ 300/ 362 ltrs complete all as specified Make : TESLA/ EPCOS/ SEIMENS/ USHA
Supply and fix as in repairs Over load protector relay suitable for Deep Freezer 200/300/362 Ltrs capacity complete all as specified. Make :- Shriram/Renutrol/Danfoss
Supply and fix as in repairs Thermostat switch suitable for Deep Freezer 200/300/362 ltrs capacity all as specified Make: Danfoss/Indfoss/Renutrol
Supply and fix in repairs Relay open type suitable for Deep Freeger 200/300/362 ltrs capacity all as specified and directed. Make : Renutrol/Shriram
Supply and fix as in repairs Fan Motor for Deep Freezer, as per sample suitable for 200/300/362 capacity complete all as specified.
Material and labour for Gas Charging of Water cooler, Refrigerator and Deep Freezer with Refigerant R 22/ R 134 A of suitable quantity to get required back pressure and effect including leak testing after and before gas charging complete all as specified .
Supply and fix as in repairs Three Pin plug top 5 Amp complete all as specified.
M/S SANJIB DEB
MS AFTAB LASKAR
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .