Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹27.2 LAccepted-AOC | L1 | Accepted-AOC Being L1 Bidder | |
| 2 | L2₹27.9 L+₹17,918.99 (0.65%)Rejected-Finance MIG 2B 65 VINAYAKA NAGAR VUDA COLONY VISAKHAPATNAM 530044 | VISAKHAPATANAM | ANDHRA PRADESH | 530044 | L2 | Rejected-Finance Being not L1 | |
| 3 | L3₹28.0 L+₹25,780.99 (0.93%)Rejected-Finance | L3 | Rejected-Finance Being not L1 | |
| 4 | L4₹33.9 L+₹6.2 L (22.2%)Rejected-Finance D NO LIG 98 RAJEEV NAGAR KURMANNAPALEM VISAKHAPATNAM 530 048 | VISAKHAPATANAM | ANDHRA PRADESH | 530048 | L4 | Rejected-Finance Being not L1 | |
| 5 | L5₹34.3 L+₹6.5 L (23.4%)Rejected-Finance 21 9TH MAIN 4TH CROSS GOWDAKEHOLA BAGALAKUNTE NAGASANDRA POST BANGALORE 560073 | BENGALURU URBAN | KARNATAKA | 560073 | L5 | Rejected-Finance Being not L1 |
Tender Value
₹46.8 L
EMD Value
₹93,600
Closing Date
28 Oct 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Garrison Engineer Utility-I Visakhapatnam
Garrison Engineer Utility-I Near Samudrika Naval Base Post Visakhapatnam -530 014
REPAIR/REPLACEMENT OF LT/HT ELECTRIC SUPPLY DISTRIBUTION SYTEM, UG CABLES AND CONNECTED ITEMS IN OFFRS MD ACCN AND NAVY ROAD, AO COMPLEX, VOLNA RADAR TOWER AT DOLPHIN HILL AND OTHER MISC WORKS UNDER AGE E/M-I OF GE (U-I) (V)
2022_MES_555360_1
8470/E8
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
Garrison Engineer Utility-I Visakhapatnam
Class D
8 documents required · 8 mandatory
₹500
Garrison Engineer Utility-I
₹93,600
Yes
9 Nov 2022
30 Sept 2022
29 Oct 2022
30 Sept 2022
28 Oct 2022
15 Oct 2022
Amount
S &F in repair of auxiliary contact block suitable for air circuit breakers of rating 400 to 1000 Amps rating as all per existing of Make: L&T/C&S/ GE/ABB
S & F in repair of Breaker Main Contact Set suitable for air circuit breakers of rating 400 to 1000 Amps rated as all per existing of Make: L&T/C&S/ GE/ ABB
S & F in repair of Spring charging handle assembly suitable for air circuit breakers of rating 400 to 1000 Amps rated as all per existing of Make: L&T/C&S/ GE/ ABB
S & F in repair of Shutter for guide frame suitable for air circuit breakers of rating 400 to 1000 Amps rated as all per existing of Make: L&T/C&S/ GE/ ABB
S & F in repair of Overcurrent release suitable for air circuit breakers of rating 400 to 1000 Amps rated as all per existing of Make: L&T/C&S/ GE/ ABB
S & F in repair of Front facia for drawout breakers suitable for air circuit breakers of rating 400 to 1000 Amps rated as all per existing of Make: L&T/C&S/ GE/ ABB
S & F in repair of arcing contacts (fixed/ moving) suitable for air circuit breakers of rating 400 to 1000 Amps rated as all per existing of Make: L&T/C&S/ GE/ ABB
S & F in repair of arc chutes (for 415 V) suitable for air circuit breakers of rating 400 to 1000 Amps rated as all per existing of Make: L&T/C&S/ GE/ABB
S & F in repair of shunt release (110 /220 V DC or 240 V/415 V AC) suitable for air circuit breakers of rating 400 to 1000 Amps rated of Make: L&T/C&S/ GE/ABB
S & F in repair of trip coil suitable for air circuit breakers of rating 400 to 1000 Amps rated all as per existing of Make: L&T/C&S/ GE/ABB
M&L for dismantling the cable connections of 3/4 pole Air circuit breaker of capacity 630 to 1000 Amps ,415 V 50 HZ of L&T /C&S/GE/ABB make, strip opening the Air circuit breaker, inspecting the parts for serviceability/overhauling complete and carrying out the following repairs/maintenance :-
a) Cleaning the insulation parts including bushings with CTC solution.
b) Checking the alignment and condition of movable and stationary contacts and adjust them all as per manufacturer's instruction manual
c) Check the bolts, nuts, washers, cotter pins and all terminal connections in place and tights. Replace the worn-out parts.
d) Check arc chutes for damage and replace damaged parts.
e) Clean and lubricate the operating mechanism with a light machine oil (SAE-20 or 30) for pins and bearings and with a non-hardening grease for the wearing surfaces . Adjust breaker operating mechanism all as per manufacturer's instructional manual . Replace if there is excessive wear and tear.
f) Checking / inspecting shunt trip coil for serviceability and replacing the same if required.
g) Replacing the badly worn or burned contacts. Checking control device free for operation.
j) Check after servicing the circuit breaker to verify the contacts move to the fully opened and fully closed positions, that there is an absence of friction and that the electrical operation is functional
Note : The rate quoted deemed to be inclusive of T&P and minor spares like lubricants, nuts/bolts/washers/ pins etc. Major spares like contacts, shunt trip coil , relays, CTs etc will be measured & paid separately under relevant schedule items
M& L for heat shrinkable end termination joint for LT UG cable including supply of kits for making end termination suitable for aluminium conducter cable of size incl fixtures and fittings etc for the following sizes complete all as specefied and directed. Make: 3M/Denson/Raychem/M-Seal
4 core of 6 to 10 sq mm
3.5 core of 16 to 35 sq mm
3.5 core of 50 to 95 sq mm
3.5 core of 120 to 185sq mm
3.5 core of 240 to 300 sq mm
3.5 core of 400 sq mm
S & F in repair calibrating, testing & commissioning of Micro processor feeder protection relay, CT input range 1Amps / 5Amps , records history- 5Nos, Min 3 Analog out put, with following protections for LT 415V feeder protection 50/ 51N (3 Phase current), 50/ 51N (Earth Over current), Relay will be on with LCD display, trip,, alarm, other assignable indication,Auxlary suppy : 220V AC/DC, Make :- C&S/ABB/Schnieder/Siemens/ L&T
S & F in repair,testing & commissioning of DC powerpack input range - 220v - 240v AC , Out put - 220VDC. Make :- C&S/ABB/Schnieder/Siemens/ L&T
Supply of CT's epoxy cast resin , with primary Current 400A - 650A or as per existing panel ratings suitable for relays and Secondary current 5A , Dual core , Dual Ratio. Protection core -Class 5P10 & Metering core - Class 0.5 , 2.5 VA . Suitable for LT 415V panel incoming feeders. Make :- C&S/ABB/Schnieder/Siemens/ L&T
Dismanltaling old damaged CT's & Fixing new supplied epoxy cast resin CT's, with primary Current 400A - 650A in LT 415V panels incoming feeder. Make :- C&S/ABB/Schnieder/Siemens/ L&T
S&F in repair of Control Wiring up to relay from CT terminals with 1 Core , 2.5 Sq mm copper cable with proper ferules & appropriate Lugs.
S&F in repair of transformer HT terminal connector bushing boots of suitable length/ size suitable for existing distribution transformers of any make/ size/ type/capacity all as directed including dismantling & refixing of HT Cable.
S&F in repair of monoplast putty for sealing HT Cable entry side gaps in HT/LT panles , transformers cable entry box of suitable length/ size all as directed & refixing of HT Cable side panel doors.
S&F in repair Expandable PU Foam Insulation Sealant Spray for sealing HT Cable entry bottom side gaps to arrest rat/insects/reptiles entry to HT/LT panels all as directed by Engineering In charge & refixing of HT Cable side panel doors.
Dismantling/taking down 11 KV oil immersed RMUs switch gear semi automatic of Make- CG Lucy from existing foundation/panel by isolating electric supply and decompounding carbonised compond from the bus bar, repair/maintenance of mechanism, examining the smooth functioning of springs, levers, moving/fixed parts, on/off operation and replacing unserviceable parts if any required , arresting any leakage in tank etc after drain out of transformer oil and removing sludge from the tank and cleaning with CTC etc, fill the chamber with tested, clean, transformer oil after cleaning, refixing the same after complete repair and maintenance and making alignment with existing panel including painting with one coat of synthetic enameled paint of existing colour and writing SM/MES no of plant complete all as specified Note :Rate quoted by the contractor includes total servicing, refixing as directed, cleaning materials, CTC, new gasket all types, springs, nut, bolt & washers, HT tape etc However replacement of oil, spare parts, cable end joints and insulating compound shall be measured and paid separately under respective item of Sch 'A' here-in- below
Supply only LH Test Access Cover FRMU Oil switche Make -CG Lucy
Supply only RH Test Access Cover FRMU Oil switche Make -CG Lucy
Supply only HRC fuse link 100 Amps Make -CG Lucy
Supply only ring insulator gasket 5602401Make CG Lucy
Supply only Fuse carrier assembly PL 5009/PL505
Supply only of gasket F/SW insulator
Supply only 11 KV insulating compound in bus bar of switch gear complete all as specified
Supply only window seals ,indication stikers and fixnishing KIT
Supply only angle boots
M&L for detecting HT/LT UG cable faults located in any stretch / depth with cable fault locator consisting of microprocessor based, identification instrument, cable tracer for exact location of under ground cable routes. Notes:- The rate quoted deemed to be inclusive of rental charges for T&P like entire cable fault locating instrument, charges for operator and transportation etc complete.
M& L for heat shrinkable straight through joint for LT UG cable including jointing kits complete for making joints suitable for aluminium conducter cable of size 3.5 core 50/70/95 sq mm complete all as specified and directed. Make: 3M/ Raychem/ Denson/ M-Seal
M& L for heat shrinkable straight through joint for LT UG cable including jointing kits complete for making joints suitable for aluminium conducter cable of size 3.5 core 120/150 sq mm complete all as specified and directed. Make: 3M/ Raychem/ Denson/ M-Seal
All as per above item No 33 but cable size but size 3.5 core 185/240 sq mm. Make: 3M/ Raychem/ Denson/ M-Seal
Supply and laying or fixing or passing through pipe or in cable ducts or on wall or in trench in repair, 11000 volts grade XLPE insulated Heavy duty (earthed),screened, PVC bedded, galvanised steel strip or wire armoured, electric power cables (heavy duty) with aluminium conductor 185 sq mm 3 core size complete all as specified and directed by Engineer-in-Charge. MAKE: Havells / Gloster / KEI Industries Ltd / Polycab / Asian Cables / Finolex
Supply and laying or fixing or passing through pipe or in cable ducts on wall or in trench in repair, 11000 volts grade XLPE insulated Heavy duty (earthed),screened, PVC bedded, galvanised steel strip or wire armoured, electric power cables (heavy duty) with aluminium conductor 240 sq mm 3 core size complete all as specified and directed by Engineer-in-Charge. MAKE: Havells / Gloster / KEI Industries Ltd / Polycab / Asian Cables / Finolex
Supply and fix cable jointing kit for 11 KV grade cable for outdoor terimination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured Al conducter cable of size 240 sq mm. Make: Birla 3M/ Raychem/ Denson/M-Seal
Supply and fix cable jointing kit for 11 KV grade cable for indoor terimination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured Al conducter cable of size 240 sq mm. Make: Birla 3M/ Raychem/ Denson/M-Seal
Supply and fix cable jointing kit for 11 KV grade cable for outdoor terimination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured Al conducter cable of size 185 sq mm. Make: Birla 3M/ Raychem/ Denson/M-Seal
Supply and fix cable jointing kit for 11 KV grade cable for straight through outdoor heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured Al conducter cable of size 185 sq mm. Make: Birla 3M/ Raychem/ Denson/M-Seal
Supply and fix cable jointing kit for 11 KV grade cable for indoor terimination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured Al conducter cable of size 185 sq mm. Make: Birla 3M/ Raychem/ Denson/M-Seal
Excavation in trenches n.exc 1.5 m wide and not exc 1.5 m depth and getting out in soft / loose soil complete all as specified and directed.
Removal of surplus excavated material of any type to a distance not exceeding 50 m and depositing where directed at a level not exc. 1.5 m above the starting point complete all as specified and directed.
Returning and filling in of excavated material any type including spreading, levelling, watering and well ramming in layers not exceeding 25 cm each complete all as specified and directed.
M&L for sand cushioning for underground cable protection complete all as specified. Note: Punned thickness shall only be measured and paid.
Supply and laying precast concrete cable covers class HV type 1 flat size 300 x 180 x 40 mm laid along alignment of cable as protection to cable in trenches complete all as specified and directed
Supply and fix or laid in road crossing/ fixed to poles, GI Pipe of 100 mm size light grade for protection of cable complete all as directed Make: Jindal Steel / Prakash / Surya Roshini / Tata
Making trench through horizontal earth Boaring for road/ foot path /hard standing/culvert etc for inserting GI protection pipe for drawing of cable and complete all as directed.
S&F in repair MCCB 4 pole, 415 V, adjustable type 630Amps with breaking capacity 50 KA including necessary modification in the panel complete all as specified and as directed. make: GE/L&T/Havells/Indoasian/Legrand
S&F in repair MCCB 4 pole, 415 V, adjustable type 400Amps with breaking capacity 35 KA including necessary modification in the panel complete all as specified and as directed. make: GE/L&T/Havells/Indoasian/Legrand
S&F in repair MCCB 4 pole, 415 V, adjustable type 250 Amps with breaking capacity 35 KA including necessary modification in the panel complete all as specified and as directed. make: GE/L&T/Havells/Indoasian/Legrand
S&F in repair MCCB 4 pole, 415 V, adjustable type 200 Amps with breaking capacity 35 KA including necessary modification in the panel complete all as specified and as directed. make: GE/L&T/Havells/Indoasian/Legrand
S&F in repair MCCB 4 pole, 415 V, adjustable type 100 Amps with breaking capacity 35 KA including necessary modification in the panel complete all as specified and as directed. make: GE/L&T/Havells/Indoasian/Legrand
M&L in repair for earthing complete with GI earth plate electrode of size 60cm x 60cm x 6 mm thick burried directly in ground (earth pit not less than 2.25 m deep below ground level) with top edge of the plate not less than 1.5m below the normal ground level connected with GI strip 32 x 6mm by means of bolts, nuts, check nuts & washers of galvanished iron or steel including necessary excavation and earth work in any type of soil, removing surplus soil to a distance not exc 50m, with and including PCC chamber in PCC (1:2:4), type B1,using (20mm graded stone aggregate), "mild steel angle iron frame" made out of MS angle iron of size 40x 40 x 6 mm thick duly painted with two coats of synthetic enamel paint over one coat of red oxide zinc chrome primer hinged with and including 6mm thick CI cover with handle, watering arrangement with funnel internally secured with wire mesh with 20mm dia medium grade pipe for watering and 40mm dia light grade, GI pipe for lead protection in & including alternate layers of charcoal dust and common salt complete all as shown in electrical "plate No 3" of SSR and connected to earthing test point all as specified and indicated including testing on completion as directed.
M & L for Filtration of Transformer Oil of transformers installed at various locations to achieve di-electric strength / BDV value not less than 60 KV at 2.5mm gap as per relevant IS with Portable Filtration Plant, testing of the oil for the di-electric strength before filtration and after filtration complete all as specified and as directed.
Supply and topping up of Transformer Oil with di-electric strength not less than 60 KV in to the Conservator Tank / Body Tank of the Transformer etc. complete all as specified and as directed. Make: Power Oil / Transol / Savita Chemicals
Supplying, Installing, Commissioning and Testing of CPRI Prototype tested, Factory made, Free Standing Floor Mounted, Dust and Vermin proof LT Cubical Panel Board, Compartmentalised, Outdoor type, fabricated with 3.15mm thick CRCA Sheet and shall be given pre-treatment for degreasing, phosphatising etc. in seven tank process and shall be powder coated with RAL7035 coat with matt finish after due preparation of surfaces. The panel shall consist of 600 Amps rating TPN bus bars of high conductivity Aluminium Alloy and shall be provided with colour coded heat shrinkable sleeves mounted on porcelain insulator supports, suitable double Compression Copper Cable Glands and panel shall be provided with separate compartments for each switch, with gland plates, lifting hooks, shutter type ventilating louver at both top & bottom duly internally secured with wire mesh, with suitable internal wiring with copper cable of suitable size, including instrumentation such as Ampere Meter, Volt Meter, Phase Indicating LED
jyothi constructions
M/s NATIONAL ENGINEERING CONSTRUCTIONS CO
MONITOR ENGINEERING WORKS
SRI MAHALAKSHMI CONSTRUCTIONS
UV POWER TECH
M/S CHANDRA ENGINEERS AND CONTRACTORS
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .