Office of Dy.Ch.Eng.MnE.ES.MCGM First Floor LBS Octroi Naka Building LBS Marg Mulund West MUMBAI
Refurbishment of Air Pollution Control System along with operation n maintainence CSMC at Cheetah Camp Hindu Cemetery in ME ward.
2026_MCGM_1301328_1
DyCEMNE343ES
Open Tender
Supply, Erection and Commissioning
Percentage
2155 days
Cheetah Camp Hindu Cemetery
Please refer Tender documents.
2 documents required · 2 mandatory
₹23,559
₹2.3 L
Office of Dy.Ch.Eng.MnE.ES.
12 May 2026
12 May 2026
20 May 2026
12 May 2026
18 May 2026
12 May 2026
14 May 2026
This is a percentage-rate BOQ. The schedule below shows estimated quantities and rates. Bidders quote a single percentage above or below the total estimated cost.
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1I – Refurbishment of APC System | |||||
| 1.01 | Dismentaling of old pyre | 4 | Each | 8,648 | ₹34,592 |
| 1.02 | Work of casting,grinding ,drilling and supply of C.I.pyre set | 4 | Nos. | 1,89,116 | ₹7,56,464 |
| 1.03 | Construction of pyre foundation | 4 | Nos. | 1,04,993 | ₹4,19,972 |
| 1.04 | Work of supply and installation of hood above the pyre made out of 2 mm thick S.S 410 sheet with necessary M.S. supporting angles / channels and providing connection to main duct as per Specifications. | 4 | Nos. | 2,57,794 | ₹10,31,176 |
| 1.05 | Work of supply and Installation of blower/ exhaust fan assembly for capacity of blower will be approx. 18000 CuM / Hr. at 300mm to 400mm WG pressure the impeller and casing shall be fabricated from SS 304 material. The impeller shall be dynamically balanced. The blower shall be coupled with 3Ph, 440V, 50 Hz T.E.F.C. Squirrel cage inductions motor (Crompton/ABB/Siemens) of suitable capacity, as per ISI specification. The blower assembly shall have silencer with antivibration absorbed to reduce noise. The blower casing shall have inspection cover and separate drain plug at bottom to remove moisture entrapped. Including 1 set of rotating element of blower set. | 2 | Nos. | 7,04,358 | ₹14,08,716 |
| 1.06 | Work of supply and installation of vertical cyclone water scrubber made out of S.S 304 material of suitable design. The thickness of bottom plate shall be 6 mm and scrubber body shall be 3mm thick plate for inner and outer shell, shall be used the spray nozzles, Mist (water) eliminator, water seal system heat resistance inspection- window, sump tank (2 CuM approx.) with foundation, cover, strainer, valve, baffle to separate solid particles from water etc. pump with piping and fitting shall be provided with proper design. Tank made from 6mm thick M.S plate shall be internally painted with chlorinated rubber paint. Suitable size PVC drains pipes shall be connected to the nearest existing MCGM drainage. The scrubber shall have firm support of M.S channels/ I- beam grouted in cement concrete foundation. The design of water scrubber system shall ensure to limit the exhaust emission within the permissible limit as specified by CPCB. Including 1 set of spares water spray nozzles etc. shall be provided along with equipment. | 2 | Nos. | 17,60,893 | ₹35,21,786 |
| 1.07 | Work of Supply and installation of main duct made out of 3 mm thick S.S 304 plate shall be connected with hood outlet, water scrubber unit, exhaust air blower, bypass arrangement of scrubber etc. the end flanges of ducting shall be 6 mm thick x 40 mm wide made out of S.S 304 material . The ducting shall be provided with S.S. 304 nuts, bolts, washer; asbestos rope etc. ducting shall be installed at site at suitable height with M.S. angle/ channel/ brackets etc. taking support of existing shed M.S. I Beam/ support as required. | 82 | Mtr. | 23,244 | ₹19,06,008 |
| 1.08 | Work of supply and installation of damper assembly of 600 mm dia made out of 3 mm thick having 6 mm thick rotating flap inside. The damper shall be provided with S.S chain for smooth operation of damper flap. | 12 | Nos. | 27,470 | ₹3,29,640 |
| 1.09 | Work of Supply and installation of electrical panel: C.R.C.A steel of 14 SWG for panel, 16 SWG for door shall be used. The panel shall have 25 x25x 3 mm M.S. Angle frame, I.S.M.C. at base, 60 x 10 mm S.S. 304 bolts, nuts spring washer , reversible lifting eye/ hook, self-draining provision, doors with insulated thumb screw, powder coated knobs, lockable handles, name plates, rating plates & label for caution notice (danger board) with proper description/ details. External and internal white labels shall be engraved and filled with black colour. The switch gears, tinned copper bus bars, separate compartments for feeders, bus bars & switchgears, current carrying capacity as per I.S. standard, voltmeter, ammeter, energy meter. Power factor meter, hour meter & R,Y, B, indicators shall be provided. I&T/Siemens make components only be used. The panel drawing shall be got approved before fabrication. The panel shall be duly painted & grouted as per site requirement. | 2 | Job | 1,97,221 | ₹3,94,442 |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.32 MB
SBDCheetacamp.pdf
Tender Documents • 4.38 MB
BOQ_2234881.xls
BOQ • 0.40 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .