| Sl No | Description | Qty | Unit | ANIKET COOLING AND REFRIGERATION CO L1 | SUPARNA REFRIZARATION L2 | CHATTERJEE ELECTRICALS L3 |
|---|---|---|---|---|---|---|
| 1.01 | Dismantling 2.5 TR damaged Compressor at server room, 1.5 TR at Dr. Rest Room & 2 TR at labour room after disconnecting every equipment by gas cutter, including Tools & Instrument | 3 | Item | 1,000 ₹3,000 | 948 ₹2,844 Lowest | 950 ₹2,850 |
| 2.01 | Reinstallation of 2 TR split type AC machine indoor & outdoor unit with bracket angle at Server Room, including Tools & Instrument | 1 | Item | 1,500 ₹1,500 | 995 ₹995 Lowest | 1,000 ₹1,000 |
| 3.01 | Overhauling of 1.5/2 TR Split indoor & outdoor unit & Window machines by jet pump chemical wash after opening the condenser coil cover, including Tools & Instrument | 40 | Nos | 700 ₹28,000 Lowest | 995 ₹39,800 | 1,200 ₹48,000 |
| 4.01 | Overhauling of 3 TR indoor & outdoor unit by jet pump chemical wash after opening the condenser coil cover, including Tools & Instrument | 4 | Nos | 850 ₹3,400 Lowest | 1,240 ₹4,960 | 1,250 ₹5,000 |
| 5.01 | Overhauling of 5 TR unit by jet pump chemical wash after opening the condenser coil cover,including Tools & Instrument | 6 | Nos | 1,000 ₹6,000 Lowest | 1,249 ₹7,494 | 1,250 ₹7,500 |
| 6.01 | Overhauling of 7.5 TR HAT type unit by jet pump chemical wash after opening the condenser coil cover, including Tools & Instrument | 3 | Nos | 1,250 ₹3,750 Lowest | 1,990 ₹5,970 | 2,000 ₹6,000 |
| 7.01 | Overhauling of 8.5 TR Ductable unit by jet pump chemical wash after opening the condenser coil cover, including Tools & Instrument | 2 | Nos | 1,000 ₹2,000 Lowest | 2,480 ₹4,960 | 2,500 ₹5,000 |
| 8.01 | Takendown,Shifting & reinstallation of indoor & outdoor machine | 1 | Item | 2,500 ₹2,500 | 980 ₹980 Lowest | 1,000 ₹1,000 |
| 9.01 | Disconnecting damage condenser coil 1 no. 5 TR A.C Machine disconnecting refrigerant hard round copper pipe, 5/8 suction line & 3/8 liquid line by gas welding at server room,including Tools & Instrument | 1 | Nos | 1,000 ₹1,000 Lowest | 21,200 ₹21,200 | 21,500 ₹21,500 |
| 10.01 | Replacement of new 2.5 TR capacity 3/8" compressor condenser coil make - Hitachi, installed by welding with 43% silver brazing at server room (Make- Hitachi/Voltas/ Daikin/ Bluestar/ Carrion) | 2 | Item | 21,500 ₹43,000 | 2,472 ₹4,944 Lowest | 2,500 ₹5,000 |
Tender Value
₹3.9 L
EMD Value
₹7,704
Closing Date
22 May 2026, 11:00 amClosed
AE/NKHESD
N.K.H. Electrical Sub Division Purta Bhawan
Urgent Dismantling, Shifting, and Overhauling of AC Units Associated with Civil Renovation at Salt Lake SD Hospital
2026_WBPWD_5013918_1
WBPWD/AE/NKHESD/NIQ- 01/Q of 26-27
Open Tender
ELECTRICAL WORKS ORG
Item Rate
7 days
KOLKATA
Please refer Tender documents.
3 documents required · 3 mandatory
₹7,704
1 Aug 2026
12 May 2026
25 May 2026
12 May 2026
22 May 2026
14 May 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1.01 | Dismantling 2.5 TR damaged Compressor at server room, 1.5 TR at Dr. Rest Room & 2 TR at labour room after disconnecting every equipment by gas cutter, including Tools & Instrument | 3 | Item | 1.25 | ₹3.75 |
| 2.01 | Reinstallation of 2 TR split type AC machine indoor & outdoor unit with bracket angle at Server Room, including Tools & Instrument | 1 | Item | - | - |
| 3.01 | Overhauling of 1.5/2 TR Split indoor & outdoor unit & Window machines by jet pump chemical wash after opening the condenser coil cover, including Tools & Instrument | 40 | Nos | 100 | ₹4,000 |
| 4.01 | Overhauling of 3 TR indoor & outdoor unit by jet pump chemical wash after opening the condenser coil cover, including Tools & Instrument | 4 | Nos | 53 | ₹212 |
| 5.01 | Overhauling of 5 TR unit by jet pump chemical wash after opening the condenser coil cover,including Tools & Instrument | 6 | Nos | 10 | ₹60 |
| 6.01 | Overhauling of 7.5 TR HAT type unit by jet pump chemical wash after opening the condenser coil cover, including Tools & Instrument | 3 | Nos | 11 | ₹33 |
| 7.01 | Overhauling of 8.5 TR Ductable unit by jet pump chemical wash after opening the condenser coil cover, including Tools & Instrument | 2 | Nos | - | - |
| 8.01 | Takendown,Shifting & reinstallation of indoor & outdoor machine | 1 | Item | 10 | ₹10 |
| 9.01 | Disconnecting damage condenser coil 1 no. 5 TR A.C Machine disconnecting refrigerant hard round copper pipe, 5/8 suction line & 3/8 liquid line by gas welding at server room,including Tools & Instrument | 1 | Nos | 22 | ₹22 |
| 10.01 | Replacement of new 2.5 TR capacity 3/8" compressor condenser coil make - Hitachi, installed by welding with 43% silver brazing at server room (Make- Hitachi/Voltas/ Daikin/ Bluestar/ Carrion) | 2 | Item | - | - |
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 1.14 MB
BOQ_5081801.xls
BOQ • 0.41 MB
2911_II.pdf
Tender Documents • 0.54 MB
NIQ01-Corrigendum.pdf
PDF • 1.13 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .