REPAIR/COMPREHENSIVE MAINT OF HOT AND COLD WATER COOLERS WITH INBUILT PURIFIER AND COLD WATER COOLERS AND CONNECTED WORKS AT VARIOUS LOCATIONS NAVAL BASE KOCHI
2026_MES_768551_1
8659/E8
Open Tender
Electrical and Maintenance Works
330 days
KOCHI
Please refer Tender documents.
7 documents required · 7 mandatory
₹500
GE NS KOCHI
₹75,980
Yes
29 May 2026
29 May 2026
22 Jun 2026
29 May 2026
19 Jun 2026
13 Jun 2026
29 May 2026 - 30 May 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1Material and labour for monthly comprehensive maintenance , repair and servicing of 'Best Water Doctor' water cooler with normal, hot and cold water dispending system of 85/90/125 ltr capacity of make:- Cross field. Including covering all spares/parts if found un serviceable during the period. Replacement of micro candle, activated carbon and other consumable once after every six month like servicing the air dryer bottleand resetting the ozone generator. which ever be required to provide smooth function of the machine, complete all as specified and directed Note :- (1) The comprehensive maintenance shall be done through OEM or authorised agency of OEM, MOU between OEM and contractor to be submitted before commencement of work. (2) The parts shall be genuine and from original equipment manufacturer (OEM) and approved by GE. | |||||
| 1.01 | (3) The contractor is responsible to carry out services through OEM during the contract period or as per users requirement to ensure the serviceability of the machine.
(4) All body parts and other accessories shall be thoroughly cleaned to remove strains etc with suitable solution, during the service time.
(5) Any break down / complaints shall be attend and with in the same day and rectification shall be intimated.
(6) The rates quoted for above items shall be included for replacement of any spares becoming unserviceable during the period and no extra claim shall be allowed.
(7) A penalty of Rs. 2000/- per day will be levied in case breakdown of machine more than 24 hrs from the time of complaint registration due to non attending.
(8) The contractor has to submit no due cirtificate from the the OEM before claming RAR.
(9) The contractor has to provide sufficient numbers of all the required spare parts during the contract peroid so that all the complaints to be rectified on the same day. | - | - | - | - |
| 2 | Material and labour for attending day to day complaints pertains to various water cooler of make Voltas/Usha/Blue Star and water filter of any make and capacity as and when required by Skilled Mechanic and helper with necessary tools and plants for checking the water cooler at existing location, find out the faults, complete and rectification of the defected water cooler and making it serviceable in complete all as specified and directed
Note:- Minor parts costing up to Rs 100 where required, deems to be inclusive of the rate quoted. Other major parts will be paid under relevent items. | 300 | Each Job | - | - |
| 3 | Materal and labour for general servicing of water cooler of capacity 40/40, 40/80 or 60/120 Litres after taking down from the existing position, transporting to workshop, clean internal parts, clean external cover with suitable liquid/ solvent, clean filter/ washing with water, replace the unserviceable parts if any including refixing the Water Cooler in same/ other location and connecting, commissioning complete all as specified and directed. | 10 | Each Job | - | - |
| 4 | Materal and labour for general servicing of water cooler of capacity 40/40, 40/80 or 60/120 Litres after taking down from the existing position, clean internal parts, clean external cover with suitable liquid/ solvent, clean filter/ washing with water, leak testing at same location, replace the unserviceable parts if any including refixing the Water Cooler in same/ other location and connecting, commissioning complete all as specified and directed
Note:- Charging of refrigerant gas will be measured and paid under relevant schedule item complete all as specified and directed | 300 | Each Job | - | - |
| 5 | Supply and fix in replacement, hermetically sealed compressor unit suitable for water cooler of capacity 40/40, 40/80 litres capacity of the existing unserviceable sealed compressor unit including gas charging and connecting up complete all as specified and directed | 5 | Each Job | - | - |
| 6 | All as per item No 5 here in before but suitable for Water Cooler of capacity 60/120 Litres complete all as specified and directed. | 2 | Each Job | - | - |
| 7 | Supply and fix in repair fan motor 240 Volt with leaf suitable for water cooler of capacity 40/80/120 litres complete all as specified and as directed. | 32 | Each | - | - |
| 8 | Supply and fix in repair PVC float valve assembly 15mm bore suitable for water cooler complete all as specified and as directed | 25 | Each | - | - |
| 9 | Supply and fix in repair 15 mm bore cock tap suitable for water cooler complete all as specified and as directed. | 25 | Each | - | - |