Loading…
Loading…
Tender Value
₹65.8 Cr
EMD Value
₹5 L
Closing Date
24 Sept 2026, 5:00 pm
MR Ahammad Danish
CE(Bilaspur)
Construction of Tamnar Bypass (Four Lane) Road Length 8.50 Km. Distt. Raigarh
198750
NIT NO:878/TC/2026-27
OPEN TENDER
WORKS
PERCENTAGE
20 days
CE(Bilaspur)
Required Past Technical Experience: AS PER NIT
Required Financial Turnover (in INR): AS PER NIT
Required Bid Capacity (in INR): AS PER NIT
17 documents required · 17 mandatory
Public Works Department (PWD)
WORKS
MR Ahammad Danish
OPEN TENDER
PERCENTAGE
OPEN TO ALL
CE(Bilaspur)
PWD Circle, Bilaspur
Division Raigarh
120
20
No
0
198750
24 Sep, 2026 5:00:00 PM IST
29 Sep, 2026 10:00:00 AM IST
3 Sep, 2026 5:00:00 PM IST
NIT NO:878/TC/2026-27
Construction of Tamnar Bypass (Four Lane) Road Length 8.50 Km. Distt. Raigarh
500000.00 INR
RTGS/CHALLAN (ONLINE) Internet Banking (ONLINE)
658240000.00
2
28 Sep, 2026 5:00:00 PM IST
658240000
AS PER NIT
AS PER NIT
AS PER NIT
0.00 INR
21d 21h 53m
17 documents required · 11 mandatory · 6 optional
₹0
₹5 L
2 Sept 2026
2 Sept 2026
29 Sept 2026
3 Sept 2026
28 Sept 2026
Clearing and grubbing road land including uprooting rank vegetation, grass, bushes, shrubs, saplings and trees girth up to 300 mm, removal of stumps of trees cut earlier and disposal of unserviceable materials and stacking of serviceable material to be used or auctioned up to a lead of 1000 meters including removal and disposal of top organic soil not exceeding 150 mm in thickness if required and as per relevant clauses of section- 200 A In area of light jungle
Excavation in Soil (by Mechanical Means.) Excavation for roadway in soil using mechanical means including loading in tipper for carrying of cut earth to embankment site and unloading with all lifts and lead upto 1000 meters as per relevant clauses of section 300.
Compacting Original Ground ii) Compacting Original Ground supporting embankment Loosening, leveling and compacting original ground to facilitate placement of first layer of embankment, scarified to a depth of 150 mm, mixed with water at O.M.C. and then compacted by rolling so as to achieve minimum dry density as given in table 300-2 for embankment construction.
Transportation of different other material i/c loading & unloading e) Excavated/compacted ordinary & other soil measured as per clause 301.8, 304.4 and 305.8 ii) Beyond 1 Kms. and upto 10 Kms. (Add extra for every 1 Km.)
Embankment Construction with Fly ash/Pond ash available from coal or lignite burning Thermal Plants as waste material. (Construction of embankment with fly ash conforming to table 1 of IRC:SP:58-2001 obtained from coal or lignite burning thermal power stations as waste material, spread and compacted in layer of 200mm thickness each at OMC, all as specified in IRC:SP:58-2001 and as per approved plans.)
Construction of Embankment with Material Deposited from Roadway Cutting (Construction of embankment with approved materials having C.B.R.>5 (unless specified otherwise in the contract) deposited at site from roadway cutting and excavation from drain and foundation of other structures graded and compacted to meet requirement of table 300-2)
Granular Sub-base as per Table:- 400-1. Construction of granular sub-base by providing graded Material, , carriage of mixed Material to work site, spreading in uniform layers with motor grader on prepared surface watering, rolling and compacting with vibratory power roller at OMC to achieve the desired density, complete as per clause 401. (A) Plant mix method (with Mechanically crushed stone only). (b) For Sub-base cum drainage layer or upper sub-base with (i) Grading-V Material
Grading-VI Material
Dry Lean Cement Concrete Sub-base as per IRC:SP-49 (Construction of dry lean cement concrete Sub-base over a prepared sub-grade with coarse and fine aggregate conforming to IS: 383, the size of coarse aggregate not exceeding 26.5 mm, aggregate cement ratio not to exceed 15:1, aggregate gradation after blending to be as per table 600-1, cement content not to be less than 150 kg/cum, optimum moisture content to be determined during trial length construction, concrete strength not to be less than 10 Mpa at 7 days, mixed in a batching plant, transported to site, laid with a paver with electronic sensor, compacting with 8-10 tonnes vibratory roller, finishing and curing as per clause 601.)
Cement Concrete Pavement (Construction of un-reinforced, dowel jointed, plain cement concrete pavement as per IRC:58 over a prepared sub-base, coarse and fine aggregate conforming to IS:383 and graded as per table 600-3 mixed in a batching and mixing plant as per approved mix design, transported to site, laid with a fixed form or slip form paver, spread, compacted and finished in a continuous operation including provision of contraction, expansion, construction and longitudinal joints, joint filler, separation membrane, sealant primer, joint sealant, debonding strip, dowel bar, tie rod, admixtures as approved, curing compound, finishing to lines and grades as per drawing as per clause 602.) (i) With Cement concrete grade M-40 and minimum cement content (a), 400 kg/cum.
Providing and laying Reinforced Cement Concrete pipe NP 3 / prestressed concrete pipe on first class bedding. (Laying Reinforced cement concrete pipe NP3 /prestressed concrete pipe for culverts on first class bedding of granular material including fixing collar with cement mortar 1:2 but excluding excavation, protection works, backfilling, concrete and masonry works in head walls and parapets) A) 450 mm dia
600 mm dia
Providing and laying of a reinforced cement concrete pipe duct, 300 mm dia., across the road ( new construction ) , extending from drain to drain in cuts and toe of slopes to toe of slopes in fills, constructing head walls at both ends, providing a minimum fill of granular material over top and sides of RCC pipes as per IRC: 98- 2011, bedded on a 0.3 m thick layer of granular material free of rock pieces , outer to outer distance of pipes at least half dia of pipe subject to minimum 450 mm in case of double and triple row ducts , joints to be made leak proof, invert level of duct to be above higher than ground level to prevent entry of water and dirt, all as per IRC:98-2011 and approved drawings. (i) Single row for one utility service
Double row for two utility service
Half Brick Circular Tree Guard, in 2nd class Brick, internal diameter 1.25 meters, and height 1.2 meters, above ground and 0.20 meter below ground (Half brick circular tree guard, in 2nd class brick, internal diameter 1.25 meters, and height 1.2 meters, above ground and 0.20 meter below ground, bottom two courses laid dry, and top three courses in cement mortar 1:6 (1 cement : 6 sand) and the intermediate courses being in dry honey comb masonry, as per design complete)
Providing and planting of 4’0” to 5’0” heighted Ficus prestige/Blackiana plants with 1’6” x 1’6” depth pit formation and soil preparation, (Mixing organic manure and plant’s protection insecticide). Up to 4 month maintenance.
Providing and planting of Golden durenta multi branches plants for showing mass effect in 0’6” x 0’6” distance with soil preparation work’s, (Mixing organic manure and plant’s protection insecticide). Up to 4 month maintenance.
Providing and planting of dwarf red Ekalyha plants showing mass effect view with 0’9” x 0’9”xl’0” depth pit formation and soil preparation work’s, (Mixing organic manure and plant’s protection insecticide). Up to 4 month maintenance.
Providing and planting of Bogenbelia dwarf, chandni dwarf, kaner dwarf vr flower bearing plants with O’9” x 0’9” depth pit formation and soil preparation work’s, (Mixing organic manure and plant’s protection insecticide). Up to 4 month maintenance.
Construction of RCC open drain (i) Construction of RCC open drain 1.0m x 1.0m inside dimension lined with 150 mm thick RCC M-20 walls, 150 mm thick CC M-20 foundation, over 100 mm thick (Av) leveling course in PCC M-15 including excavation , dressing of sides and bottom, provision of HYSD reinforcement consisting 10 mm dia horizontal bars @ 150 mm c/c and L-shaped 10 mm dia vertical bars @ 150 mm c/c (L=1400 mm) including cutting, bending and binding wire, placing in position, providing shuttering and concreting by using concrete mixer, compaction by vibration etc complete as per drawings and technical specifications
Construction of RCC open drain 0.60m x 0.60m inside dimension lined with 120 mm thick RCC M-20 walls, 120 mm thick CC M-20 foundation, over 100 mm thick (Av) leveling course in PCC M-15 including excavation , dressing of sides and bottom, provision of HYSD reinforcement consisting 8 mm dia horizontal bars @ 150 mm c/c and L-shaped 8 mm dia vertical bars @ 150 mm c/c (L= 800 mm) including cutting , bending and binding wire, placing in position , providing shuttering and concreting by using concrete mixer, compaction by vibration etc complete as per drawings and technical specifications.
Construction of RCC Drain/Cover/Chamber ii) Construction of RCC drain/chamber cover, placing in position, providing shuttering and concreting by using concrete mixer, compaction by vibration etc complete as per drawings and technical specifications excluding reinforcement. with RCC M-20
Supplying, Fitting and Placing un-coated HYSD bar Reinforcement in drain/cover/chamber complete as per Drawing and Technical Specifications.
Retro- reflectrorized Traffic signs (Providing and fixing of retro-reflectrorized cautionary, mandatory and informatory sign as per IRC:67-2012 made of retro- reflective type sheeting vide clause 801.3, fixed over aluminum sheeting, of required thickness supported on a mild steel back frame of ISA 40 x 40 x 5 mm and mild steel angle iron post 75 mm x 75 mm x 6 mm firmly fixed to the ground by means of properly designed foundation with M 15 grade cement concrete 45 cm x 45 cm x 60cm, 60 cm below ground level as per approved drawing and painting all components of the signs and supports as per clause 7.2 of IRC:67-2012) B) Made of Class-B High Intensity Micro Prismatic Grade sheeting of Type IV (for MDR) a) With Aluminum Sheeting of 2 mm thickness i) 900 mm equilateral triangle
800 mm x 600 mm rectangular
900 mm Octagon
750 mm circular
Providing & Fixing Hazard Marker Partial Reflective hazard marker as per clause 15.66 of IRC 67-2022, made of 16 gauge (1.6 mm) thick mild steel sheet Confirming to IS: 2062 Painted with one coat of Zinc Chromate Stoving Primer and two coats of Black Stove Enamel (Oven Baked) paint with 10 cm alternative bands of yellow Retro- Reflective Sheeting of Micro Prismatic Grade pasted as per IRC:79 and black paint, including back frame made of angle iron 25x25x3mm mounted over one MS angle Iron post of size 50X50X6 mm of 1.65 meter long duly painted with synthetic enameled paint block including bolts and fixing the same in M-15 concrete black of size 30X30X30 cm Including transportation etc. Complete
Providing and fixing of Route Marker Sign Board with HighIntensity Grade Retro-reflective Sheeting ( as per section 801.3 ) made of 1.5 mm thick aluminum sheet. The single vertical post made from M.S. angle post (75 mm x 75 mm x 6 mm) firmly fixed to the ground by means of properly designed foundation with M15 grade cement concrete 45 cm x 45 cm x 60 cm, 60 cm below ground level as per approved drawing. Size of board 600 mm x 440 mm for the upper board and 300 mm x 250 mm for the lower plate as per IRC Specifications.
Multi-Directional Sign Board with Central Post Providing and erecting Multi-Directional Sign Board with Central Post and mounting four or three faces with 2 mm thick corrosion resistant aluminum alloy sheet reflectorized sign board with high intensity retro-reflective sheeting of Class-C Micro Prismatic Grade Sheeting of Type IX, with writing and direction marking, as directed by Engineer-in-Charge, including cost of sign boards and their back frames installed as per clause 802.6 over a designed support system of aluminum alloy or galvanized steel trestles and trusses of sections and type as per structural drawing requirements with following structural components. Central post: 300mm internal dia. 8mm thick and 7.20m High (6.80m + 1.20m), covered at top with 8 mm thick plate Bottom Base Plate: 750mm x 750 mm 16mm thick anchord with 8 Nos. 25mm diameter J-Bolts to the Foundation plateform. excluding cost of foundation Top Base Plates: 750mm x 750 mm 14mm thick 2 Nos.. welded 10 top of lower post of 6.0m height and bottom of upper post of 1.20m height, firmely connected together with bolts and nuts of 20mm dia. Top and bottom frames, Vertical connectors and Diagonal connectors for both frames ISA 50x50x6mm, including providing 5mm thick gusset plates of size 200mmx200mm at all conrners of top and bottom frame. Back frame of board of ISA 40x40x5mm including making all arrangements for stability of structure. (Drawing is annexed as Annexure-1) A) Sign boards of size 3.00m x 1.20m on all the Four Faces (for fourway junctions)
Sign boards of size 3.00m x 1.20m on Three Faces (for T-junctions)
Metal Beam Crash Barrier B) Type - B, "THRIE" : Metal Beam Crash Barrier (Providing and erecting a "Thrie" metal beam crash barrier comprising of 3 mm thick corrugated sheet metal beam rail, 85 cm above road/ground level, fixed on ISMC series channel vertical post, 150 x 75 x 5 mm spaced 2 m centre to centre, 2 m high with 1.15 m below ground level, all steel parts and fitments to be galvanized by hot dip process, all fittings to conform to IS:1367 and IS:1364, metal beam rail to be fixed on the vertical post with a space of channel section 150 x 75 x 5 mm, 546 mm long complete as per clause 811.3)
Road Marking with Hot Applied Thermoplastic Compound with Reflectorizing Glass Beads on Bituminous Surface (Providing and laying of hot applied thermoplastic compound 2.5 mm thick including reflectorizing glass beads @ 250 gms per sqm area, thickness of 2.5 mm is exclusive of surface applied glass beads as per IRC:35-1997. The finished surface to be level, uniform and free from streaks and holes.)
Direction and Place Identification signs with size more than 0.9 sqm size board. (Providing and erecting direction and place identification retro- reflectorized sign as per IRC:67-2012 made of reflective type sheeting vide clause 801.3, fixed over aluminum sheeting, 2 mm thick with area exceeding 0.9 sqm and fixed on a mild steel frame of size 40 x 40 x 6m m,suported on 2 Nos. mild steel angle iron posts of size 75 x 75 x 6 mm , firmly fixed to the ground with M15 grade cement concrete 45 x 45 x 60cm, 60cm below ground level as per approved drawing) B) Made of Class B High Intensity Micro Prismatic Grade Sheeting of Type IV(for MDR)
Kilo Meter Stone (Reinforced cement concrete M15grade kilometer stone of standard design as per IRC:8-1980, fixing in position including painting and printing etc) i) 5th kilometer stone (precast)
Ordinary Kilometer stone (Precast)
Hectometer stone (Precast)
Excavation for Structures (Earth work in excavation of foundation of structures as per drawing and technical specification, including setting out, construction of shoring and bracing, removal of stumps and other deleterious matter, dressing of sides and bottom and backfilling with approved material.) Ordinary soil Up to 3 m depth
Plain cement concrete complete as per drawing and Technical Specifications.PCC Grade M 15
PCC Grade M 20
Providing and laying Reinforced Cement Concrete pipe NP 4 / prestressed concrete pipe on first class bedding Laying Reinforced cement concrete pipe NP4/prestressed concrete pipe complying to IS:458, with ends casted as per the requirements of flush jointing of pipes, for culverts on first class bedding of granular material including joints duely filled and finished with cement mortar 1:2 and bedding aas per clause 2904 but excluding excavation, protection works, backfilling, concrete and masonry works in head walls and parapets. C) 1000 mm
1200 mm dia
Providing and laying Pitching Stone/Boulder on slopes laid over prepared filter media including boulder apron laid dry in front of toe of embankment complete as per drawing and Technical specifications as per clause 2504.
Providing and laying Filter material underneath pitching in slopes complete as per drawing and Technical specification including trimming of slopes to proper profile and preparation of bed and as per clause 2504.
Providing Chute drains consisting of NP-2 RCC half round, 300 mm dia pipes , laid over block of C.C. 1:3:6 ( 20mm and down aggregates ) size 450 mm x 265 mm laid over filter media ( measured and paid separately ) including all false work etc. complete.
Excavation for Structures Earth work in excavation of foundation of structures as per drawing and technical specification, including setting out, construction of shoring and bracing, removal of stumps and other deleterious matter, dressing of sides and bottom and backfilling with approved material including dewatering etc. complete. I Ordinary soil (i) Upto 3 m depth
Sand Filling in Foundation Trenches as per Drawing & Technical Specifications.
Plain/Reinforced cement concrete in open foundation complete as per drawing and technical specifications (A) Using concrete mixer (i) PCC Grade M15
(ii) PCC Grade M20
Supplying, fitting and placing un-coated HYSD bar reinforcement in foundation complete as per drawing and technical specifications as per section 1600.
Providing and laying Plain/Reinforced cement concrete in sub-structure complete as per drawing and technical specifications section 1500, 1700 and 2200 (Newly laid concrete shall be covered by gunny bags). A Height upto 5m (a) Using concrete Mixer (ii)P.C.C. Grade M-20
D Height upto 5m (a) Using concrete Mixe (i) R.C.C. Grade M-20
(iii) R.C.C. Grade M-30
Supplying, fitting and placing HSD (High Strength eformed Steel) bars reinforcement in sub-structure complete as per drawing and technical specifications section 1600 and 2200.
Providing weep holes in Brick masonry/ Plain/ Reinforced concrete abutment, wing wall/return wall with 100 mm dia. AC pipe, extending through the full width of the structure with slope of 1 V: 20 H towards drawing face. Complete as per drawing and Technical specifications section 2706 and 2200.
Back filling behind abutment, wing wall and return wall complete as per drawing and Technical specification 710.1.4 of I.R.C. 78 and 2200. (i) Granular material
Providing and laying Filter material underneath pitching in slopes complete as per drawing and Technical specification including trimming of slopes to proper profile and preparation of bed as per section 2504.
Providing and laying Pitching on slopes laid over prepared filter media including boulder apron laid dry in front of toe of embankment complete as per drawing and Technical specifications as per section 2504. A Stone/Boulder
Providing and fixing in position tar paper bearing for slab as per approved drawings and specification.
Furnishing and Placing Reinforced/Prestressed cement concrete in super-structure as per drawing and Technical Specification sections 1500, 1600 and 1700 (Newly laid concrete shall be covered by gunny bags). (B) RCC Grade M30 (I) For Solid Slab Super Structure (a) Using Concrete Mixer (i) Height upto 5m
Supplying, fitting and placing HSD (High Strength Deformed Steel) bar reinforcement in super-structure complete as per drawing and technical specifications
Providing and laying Cement concrete wearing coat M-30 grade including reinforcement complete as per drawing and Technical Specifications as per relevant clause of section 2700.
PCC M 15 Grade leveling course below approach slab complete as per drawign and Technical specification and as per relevent section 2700.
Providing and laying M - 30 grade Reinforced cement concrete approach slab including reinforcement and form work complete as per droving and Technical specification and as per relevant sections 1500. 1600, 1700 and 2704.
Filler joint B) Providing & fixing 20 mm thick compressible fiber board (12 m long x 25 cm deep ) in expansion joint complete as per drawing & Technical Specification.
Providing and laying of Filter media with granular materials/stone crushed aggregates satisfying the requirements laid down in clause 2504.2.2. of MORT&H specifications to a thickness of not less than 600 mm with smaller size towards the soil and bigger size towards the wall and provided over the entire surface behind abutment, wing wall and return wall to the full height compacted to a firm condition complete as per drawing and technical specifications 710.1.4 of I.R.C. 78 and 2200.
Drainage Spouts complete as per drawing and Technical specifications of section 2705
Construction of RCC railing of M30 Grade in-situ with 20 mm nominal size aggregate, true to line and grade, tolerance of vertical RCC post not to exceed 1 in 500, centre to centre spacing between vertical post not to exceed 2000 mm, leaving adequate space between vertical post for expansion, complete as per approved drawings and technical specifications. (vide drawing No. SD/201, SD/304)
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 1.11 MB
3662590503382863201_153213_1258250143523725404_129113_Guidelines_to_Bidders_EPS_v1.pdf
NIT • 0.13 MB
1983635265691284342_198750_Form A.doc
NIT • 0.17 MB
3396135800981297123_198750_NIT.doc
NIT • 0.31 MB
6739736363083914492_198750_PQ.doc
NIT • 0.21 MB
7126412429436132698_198750_198750 Notice.docx
NIT • 0.06 MB
6214013010292755521_198750_BOQ.xlsx
BOQ • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .