Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹51,629Accepted-AOC | ₹51,629 | L1 | Accepted-AOC L1 |
| Sl No | Description | Qty | Unit | ARAVIDAKSHAN K L1 |
|---|---|---|---|---|
| 1.00AMC | ||||
| 1.00 | OD51090/2025-2026:Annual One Time Maintenance Service Contract For Diesel Powered Electric Generators 62.5 KVA at the site by an authorized company technician, including 1.Checking, Overall condition/appearance of equipment (controls, leaks, loose wires). 2. change all fuel and oil filters in this contract and if required change the belts and the amount will be paid separately. 3. Inspect and adjust rack on unit injector or fuel distributor pump according to manufacturer's instructions. Check injector pump and injectors and verify flow rate, pressure, and spray pattern. 4. Adjust the governor for proper operating speed if required. 5. Flush cooling system and check hoses. Replace hoses if required by COR. Replace coolant by the contractor and hose if required and the payment for that items will be made separately. I 6. Brush and clean the coolant heat exchanger, in and out and painted the outer metal cover. 7. Tighten control and power wiring connections. 8. Check the calibration of voltage-sensing relays/devices. 9. Change Lubricating oil. Review the Material Safety Data Sheet (MSDS) for proper disposal of used oil. (the charge for the oil given separately) 101. Inspect and clean generator rotor, stator, exciter and battery Charger etc. 11. Check the vibration of the Engine. 12. Clean voltage regulator, and control panel etc 13. Measure and record resistance reading of generator windings with insulation tester (Megger).. 14. Inspect safety shutdown devices. This includes simulated faults on low oil pressure cut-off, high water temperature cut-off, over-speed cut-off and failed start. 15. Check generator bearings and bearing grease. Lubricate in accordance with manufacturer's instructions. 16. Visually check bus bars, bracing, and feeder connections for cleanliness and signs of overheating. 17. Perform other work prescribed by the manufacturer and reported Overall Condition Assessment of the DG set. 18Run generator set (under load) to check voltage, check frequency, check instrument system and make adjustments. 19. Clean generator room/cabin and remove all debris. as per the manufactures checklist and make the unit a good working condition. Inspection shall be carried out at least once in a month and complaints must be attended within three hours with out fail | 1 | job | 21,235 ₹21,235 Lowest |
| 1.00 | OD56752/2025-2026:Supply and renewal of AVR of 62.5kVA DG set | 1 | each | 5,130 ₹5,130 Lowest |
| 1.00 | OD52020/2025-2026:Supply and refilling required quantity of Genuine Engine Oil | 20 | Litre | 355 ₹7,100 Lowest |
| 1.00 | OD52043/2025-2026:Supply of genuine fuel filter cum water separator for DG set. | 2 | each | 1,520 ₹3,040 Lowest |
| 1.00 | OD52072/2025-2026:Supply of Genuine oil filter for DGset. | 2 | each | 1,940 ₹3,880 Lowest |
| 1.01 | OD52096/2025-2026:Supply of genuine Fuel strainer for DG set. | 2 | each | 194 ₹388 Lowest |
| 1.01 | OD51091/2025-2026:Supply of Genuine Primary Air Filter in place of faulty one for DG set. | 2 | each | 5,165 ₹10,330 Lowest |
| 1.01 | OD52153/2025-2026:Supply of genuine Air filter safety for DG set. | 2 | each | 1,695 ₹3,390 Lowest |
| 1.01 | OD52179/2025-2026:Supply and refilling required quantity Genuine Coolent to the DG Set. | 8 | Litre | 323 ₹2,584 Lowest |
Tender Value
₹51,925
EMD Value
₹1,298
Closing Date
24 Dec 2025, 6:00 pmClosed
Assistant Executive engineer
O/O ASSISTANT EXECUTIVE ENGINEER, PYIP SUBDIVISION MATTANNUR AT VELIYAMBRA
GENERAL_Pazhassi Irrigation Project _AMC for 62_5kVA Diesel Generator Set_Annual Maintenance contract for 62_5kVA DG set including general servicing at Pazhassi dam_General Electrical Work
2025_Irrig_807840_3
PWD/BLDG/TR/10046/2025_6_1_1/2
Open Tender
Electrical and Maintenance Works
Item Rate
365 days
Veliyambra
Please refer Tender documents.
11 documents required · 11 mandatory
₹555
Yes
₹1,298
Yes
3 Sept 2026
16 Dec 2025
29 Dec 2025
16 Dec 2025
24 Dec 2025
16 Dec 2025
Amount
OD51090/2025-2026:Annual One Time Maintenance Service Contract For Diesel Powered Electric Generators 62.5 KVA at the site by an authorized company technician, including 1.Checking, Overall condition/appearance of equipment (controls, leaks, loose wires). 2. change all fuel and oil filters in this contract and if required change the belts and the amount will be paid separately. 3. Inspect and adjust rack on unit injector or fuel distributor pump according to manufacturer's instructions. Check injector pump and injectors and verify flow rate, pressure, and spray pattern. 4. Adjust the governor for proper operating speed if required. 5. Flush cooling system and check hoses. Replace hoses if required by COR. Replace coolant by the contractor and hose if required and the payment for that items will be made separately. I 6. Brush and clean the coolant heat exchanger, in and out and painted the outer metal cover. 7. Tighten control and power wiring connections. 8. Check the calibration of voltage-sensing relays/devices. 9. Change Lubricating oil. Review the Material Safety Data Sheet (MSDS) for proper disposal of used oil. (the charge for the oil given separately) 101. Inspect and clean generator rotor, stator, exciter and battery Charger etc. 11. Check the vibration of the Engine. 12. Clean voltage regulator, and control panel etc 13. Measure and record resistance reading of generator windings with insulation tester (Megger).. 14. Inspect safety shutdown devices. This includes simulated faults on low oil pressure cut-off, high water temperature cut-off, over-speed cut-off and failed start. 15. Check generator bearings and bearing grease. Lubricate in accordance with manufacturer's instructions. 16. Visually check bus bars, bracing, and feeder connections for cleanliness and signs of overheating. 17. Perform other work prescribed by the manufacturer and reported Overall Condition Assessment of the DG set. 18Run generator set (under load) to check voltage, check frequency, check instrument system and make adjustments. 19. Clean generator room/cabin and remove all debris. as per the manufactures checklist and make the unit a good working condition. Inspection shall be carried out at least once in a month and complaints must be attended within three hours with out fail
OD56752/2025-2026:Supply and renewal of AVR of 62.5kVA DG set
OD52020/2025-2026:Supply and refilling required quantity of Genuine Engine Oil
OD52043/2025-2026:Supply of genuine fuel filter cum water separator for DG set.
OD52072/2025-2026:Supply of Genuine oil filter for DGset.
OD52096/2025-2026:Supply of genuine Fuel strainer for DG set.
OD51091/2025-2026:Supply of Genuine Primary Air Filter in place of faulty one for DG set.
OD52153/2025-2026:Supply of genuine Air filter safety for DG set.
OD52179/2025-2026:Supply and refilling required quantity Genuine Coolent to the DG Set.
Bidder Name
ARAVIDAKSHAN K
stage.html
html • 0.03 MB
tech_eval.pdf
fin_eval.pdf
aoc.pdf
finance_1377722.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Tendernotice_1.pdf
PDF • 0.04 MB
specificconditionNEW.pdf
Other Document • 0.34 MB
BOQ_1377722.xls
BOQ • 0.30 MB
SBD.pdf
Tender Documents • 1.63 MB
NIT.pdf
Other Document • 0.02 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .