| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹67.1 LAccepted-AOC PALTA WATER WORKS GATE NO 2 NAYABASTI BARRACKPORE 24 PARGNAS N KOLKATA 700120 WB | 24 PARAGANAS NORTH | WEST BENGAL | 700120 | L1 | Accepted-AOC Accepted due to the lowest bidder | |
| 2 | L2₹75.8 L+₹6.0 L (8.67%)Rejected-AOC KANTHADHAR P O ICHAPORE NAWABGANJ DIST NORTH 24 PARGANAS PIN 743144 WB | ICHAPORE NAWABGANJ | NORTH 24 PARGANAS | WEST BENGAL | 743144 | L2 | Rejected-AOC Rejected due to other than lowest bidder | |
| 3 | L3₹85.1 L+₹15.3 L (22.0%)Rejected-AOC 71 GOLA MAHAL SADAR BAZAR BARRACKPORE KOLKATA 700120 | 24 PARAGANAS NORTH | WEST BENGAL | 700120 | L3 | Rejected-AOC Rejected due to other than lowest bidder | |
| 4 | Rejected-Technical | - | Rejected-Technical Not-Admitted |
Tender Value
₹71.5 L
EMD Value
₹1.3 L
Closing Date
1 May 2023, 6:00 pmClosed
Commander Works Engineer
Commander Works Engineers (Sub) Military Engineer Services PO- Barrackpore Dist- 24 Pgns (N) Kolkata- 700120 (W.B)
SPECIAL REPAIR TO BLDG NO. 05 (SAINIK AUDITORIUM) AT BARRACKPORE UNDER GE BARRACKPORE
2023_MES_588020_1
CWE/BKP/02 OF 2023-2024
Open Tender
Civil Works
Item Rate
180 days
GE Barrackpore
As per NIT
6 documents required · 6 mandatory
₹1,000
GE Barrackpore
₹1.3 L
Yes
20 Jun 2023
1 Apr 2023
3 May 2023
1 Apr 2023
1 May 2023
16 Apr 2023
Amount
Dismantling Asbestos cement (corrugated,semi corugated,etc) sheets in roof covering complete all as specified and directed.
S&F Pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50mm of an colour having tensile strength of 550Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and directed.
S&F Pre-painted galvalume aluminium zinc coating GI based plain steel sheet 0.50mm of any colour having tensile strength of 550Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and directed.
Dismantling wrough iron or mild steel work of any description not otherwise provided for complete all as specified and directed.
S&F only for compound girders and stanchions, lattice girders, aerial masts, staging for water tanks and the like including caps, bases, splices etc. built up from two or more beam or channel sections or angles with plates, including all lattice bars, stiffeners, gusset plates, etc. complete all as specified and directed.
S&F Roof trusses (framed) trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle channel or flat Sections) Including distance pieces, cleats etcFe 290(Gde E-165), complete all as specified and directed.
S&F Rolled mild steel Framed work as in doors or gates of angle or other section with gusset plates, rails, braces, etc., complete, drilled for fixing of steel sheeting or other covering, Doors etc. to be prepared for hanging or sliding with & including either hooks & hinges or steel hanging door fittings (exclusive of steel sheeting or other covering, running rails & guides) & hanging; also fastening & fixing complete GDE Fe410-0 or Fe 310-O, complete all as specified and directed.
M&L for 2 coats of synthetic enamel painting over a coat of red oxide zinc crome on new steel surface of any description over 10 cm width or girth not otherwise described incl preparation of surfaces complete all as specified and directed.
Demolition of Wall and ceiling boards (fibre, pulp, insulation, etc.) or insulation boards/slabs/blankets, any thickness, including cover fillets complete all as specified and directed.
S&F Anodised aluminium snap grid frame work for false ceiling size of grid 605 x 605mm and including 12mm perforated particle board/tiles for insulation and accoustic purposes, 60 x 60cm in size fixed in ceiling, fixed in snap grid complete all as specified and directed.
S&F 12mm perforated particle board/tiles for insulation and accoustic purposes, 60 x 60cm in size,fixed with nails to timber frame work or with staples on snap grid complete all as specified and directed.
M&L for 2nd class hard wood plain fillets, square,rectangular or triangular in section, clean sawn, secured with nails or brads (sectional aera exc 13 sq.cm & n exc 25 sq.cm ) as in wall panelling frame including taking down complete all as specified and directed.
Demolition of cement concrete of any description and in any position not otherwise specially provided for complete all as specified and directed.
M&L for 20mm thick rendering in CM (1:3) on fair face of brick work mixed with water proofing liquid compound on walls and roof surfaces finished even and smooth using with out using extra cement all as specified & directed. (Note : WPC shall be mixed @ 100 ml / 50 Kg bag of cement or as recommended by manufacturer and the same shall be measured and paid seperately complete all as specified and directed.
M&L for plain cement concrete (1:2:4) type B-1, (using 20 mm greded aggregate) as in roof padding 25 mm thick complete all as specified and directed.
M&L for APP based polymeric membrane minimum weighing 3.60 kg/sqm and minimum 3mm thick reinfoced with polyster non wove fabric (wt not less than 150gms/sqm) laid on primed surface by forced application over applying evenly a tack coat of industrial bitumen 85/25 at the rate of 1.2 kg sqm including cleaning surfaces complete all as specified and directed.
M&L for preparation old steel surfaces of any description exc 10 cm width or girth, not otherwise described any applying one coats of synthetic enamel paint complete all as specified and directed.
S&F in repair 110mm bore PVC ( SWR) pipes single socketed in any length with rubber ring joints,Fixed to walls, complete all as specified and directed.
S&F in repair 110mm PVC (SWR) junction single, (Single T) equal or unequal with access door type complete all as specified and directed.
S&F in repair 110mm PVC (SWR) junction single, bends with access door type complete all as specified and directed.
M&L plain cement concrete(1:3:6) type C-2, (40mm graded aggregate) 75 mm thick as in Plinth protection/and pavings finishing cement concrete surface even and fair without using extra cement complete all as specified and directed.
Taking down cement plaster any description on brick or stone walls etc including raking out joints, haking for key scrubbling down with water etc complete all as specified and directed.
Rendering 15mm thick in cement mortar (1:4) on fair face of stone surfaces /brick finished even and smooth without to using extra cement with WPC, complete all as specified and directed. Note : WPC shall be measured and paid seperately.
Rendering 15mm thick in cement mortar (1:6) on fair faces of stone surfaces /brick finished even and smooth with out using extra cement complete all as specified and directed.
Supply only integral water proofing compound complete all as specified and directed.
M&L for applying Two coat of acrylic, antifugal emusion exterior weather proof paint over a coat of Primer complete all as specified and directed.
M&L for two coat of distemper oil emulsion after preparation of new plastered surfaces of wall over a coat of alkali resistant cement primar including 3mm thcik wall care putty on wall complete all as specified and directed.
M&L for two coat of oil bound distemper over one coat of clearcolle primer on old decorated surfaces including complete removal of existing treatment surfaces, inciuding stipping nails, holes ,filling the cracks with 3 mm thick wall care putty complete all as specified and directed.
M&L for Complete removal of existing wall surfaces and applying Two coat of acrylic, antifugal emusion exterior weather proof paint complete all as specified and directed.
M&L for plain cement concrete (1:3:6) type C 2, (using 40 mm .graded aggregate) as in surface channels and drains complete all as specified and directed.
Extra over for forming fair finished drain or channel 30 cm inner girth in cement concrete using extra cement, including forms, moulds, mitred/ stopped ends complete all as specified and directed.
Demolition of brick work built in cement morter complete all as specified and directed.
Material and labour for brickwork in cement mortar (1:6) with subclass `B' bricks straight or curved on plan exceeding 6m mean radius with old size bricksas in walls complete all as specified and directed.
Dismantling floor hearth or wall tiling including cement mortar bedding ( but not backing) and removing rubbish off the premises complete all as specified and directed.
S&F non-skid ceramic (Joint Free)coloured tiles of 7 to 8mm thick (Square/rectangular) area of each tile exceeding 0.18 sqm but n.exc 0.38 sqm in floors etc, set and jointed in neat cement slurry and pointed in coloured cement to match with including 15mm thick screed bed or bedding layer of mortar for laying floor finishes in cm 1:6 complete all as specified and directed.
S&F Glazed ceramic coloured tiles in vertical surface (350x 250x 7 mm/ 450X 350X 7mm) thick set and jointed in neat cement slurry and pointed in white or colour cement to match including 10mm thick rendering or bedding layer of cement mortar (1:4) for vertical surfaces complete all as specified and directed.
M&L for Granite work 18 to 20mm thick (table rubbed and polished) in steps, jambs, pillars, windowcills, cooking platforms and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with marble shade of following types complete all as specified and directed.
S&F in repair counter top wash basin snow white oval type (560x430x195)mm fixed over granite slab of size (750x450x18)mm including brackets, PVC connection waste pipe , waste coupling etc. complete all as specified. (Make:- Jaquar No FLS-WHT-5701 for counter type or equivalent in Jaquar/Parryware/Hindware) Note : Granite rate is included in items complete all as specified and directed.
S&F in repair towel ring square with round flange complete all as specified and directed. (Make:- Jaquar, Cat No ACN - 1121BN or equivalent in Cera/Hindware/Parryware/Prayag)
S&F in repair toilet paper holder fixed to walls with chromium plated (CP) brass screws complete all as specified and directed. (Make:- Jaquar, Cat No ACN - 1151N or equivalent in Cera/Hindware/Parryware/Prayag)
S&F in repair soap dish holder complete all as specified and directed. (Make:- Jaquar, Cat No ACN - 1131N or equivalent in Cera/Hindware/Parryware/Prayag)
S&F in repair tumbler holder complete all as specified and directed. (Make:- Jaquar, Cat No ACN - 1141N or equivalent in Cera/Hindware/Parryware/Prayag)
S&F in repair Pillar Cock with 190mm extended body complete all as specified and directed. (Make:- Jaquar, Cat No KUP-35021PM or equivalent in Cera/Hindware/Parryware/Prayag)
S&F in repair bottle trap 32mm size with 300mm and 190mm long wall conection pipes and wall flanges complete all as specified and directed. (Make:- Jaquar, Cat No ALD-769L300 x 190mm or equivalent in Cera/Hindware/Parryware)
S&F in repair Vitreous China wash down water closet Rimless Bowl with Cistern for extended wall Hung WC with PP Soft Close seat cover, Hinges, Dual Flushing Cistern fitting, Accessories Set, Size 380 x 650 x 730mm, inlet including connection to drain (or outgoing pipe) and making good to floor complete all as specified and directed. (Make:- Jaquar, Cat No FLS-WHT-5353PPZ or equivalent in Cera/Hindware/Parryware)
S&F in repair Vitreous China Urinal with fixing accessories, of size (355x340x535mm) complete all as specified and directed. (Make:- Jaquar, Cat No URS-WHT-13261 or equivalent in Cera/Hindware/Parryware)
S&F in repair health faucet with 1.00m long easy Flex tube in Chrome finish and wall Hook complete all as specified and directed. (Make:- Jaquar, Cat No ALD-565 or equivalent in Cera/Hindware/Parryware/Prayag)
S&F in repairs 15mm bore angular stop valve fancy type chromium plated with cast copper alloy screwed down high pressure with crutch or butterfly handle screwed both ends for iron pipe or for unions complete all as specified and directed. (Make:- Jaquar, Cat No CQT-23059 or equivalent in Cera/Hindware/Parryware/Prayag)
S&F in repair Brass chromium plated Tubular towel rail 20mm dia, D type, 60cm long between flanges complete all as specified and directed.
S&F in repair 15mm dia Tubes, 'medium grade' galvanised, with all fittings and fixed to walls and ceilings or laid in floors (surface or concealed type) complete all as specified and directed.
S&F in repair 20mm dia Tubes, 'medium grade' galvanised, with all fittings and fixed to walls and ceilings or laid in floors (surface or concealed type) complete all as specified and directed.
S&F in repair PVC (SWR) vent cowl 110mm bore complete all as specified and directed.
S&F in repair 75mm bore PVC (SWR) pipes single socketed in any length with rubber ring joint fixed to wall complete all as specified and directed.
S&F in repair PVC (SWR) bends with access door of radius 75mm bore complete all as specified and directed.
S&F in repair PVC (SWR), junction single, (Single T) with access door equal or unequal 75 mm bore complete all as specified and directed.
Demolition of cement concrete in ground floors and pavings (unreinforced) n.exc 15 cm thickness (below or above ground level) complete all as specified and directed.
M&L for 100 mm thick plain cement concrete (1:4:8), type D-2, (using 40mm graded aggregate) complete all as specified and directed.
M&L for Sand cushioning below interlocking paver block incl spreading and levelling complete all as specified and directed.
S&F Coloured Machine pressed precast concrete interlocking paver block with grey cement and pigment any shape and size confirming to IS 15658-2006 of 60mm thickness, M-35 Grade complete all as specified and directed.
M&L for precast cement concrete (1:2:4), type B1, (using 20 mm graded aggregate) as in copings, columns, posts, boundary pillars, bed plates, pintle blocks, anchorage blocks, bonders (for stone walling), corbels, brackets, etc.(of any section indicated), with plain fair faces, including chamfers, weatherings, throating etc. and setting in CM(1:6) with joints to match complete all as specified and directed.
Taking down carefully by unsrewing from ceiling rose or outlet boxes of LED Tube Light/ LED ceiling light fittings of any wattage in any height or a place to be kept in safe custody and refix the same to it own position after cleaning dust particles and connections to be checked complete all as directed and specified.
Taking down carefully copper/aluminium point wiring (light,fan,bell, socket or power) complete,including fixtures and fittings such as switches, ceiling roses, holders,regulators, sockets, light fittings and including making good the disturbed surfaces to match with existing surface and colour shade with putty at necessary holes for smooth finishing complete all as specified and directed complete all as specified and directed.Removing material will be the property of contractor and necessary Sch of Credit will be deducted.
Material and labour for point wiring complete with 1.5 sqmm PVC insulated, FRLS type, ISI marked,conforming to IS-694/1990 unsheathed, multistranded, single core, copper conductor cable 1100 volts grade colour code cables drawn through and including PVC Conduit 20 mm dia medium grade(MMS) and including cutting, chasing work at any height and all accessories concealed in walls / roofs / floors / ceiling etc. flush mounting MS box with top,bottom,side/back wall knockout for conduit entry from any direction made out of 1.60mm thick suitable for fixing of and including white/Silver/Dark bronze colour modular blanking plate as per number of switch modules flush mounted for fixing of modular switches,sockets,fan regulators, blank plate etc and including above mentioned colour modular plate cover of required modules and including 1.5 Sqmm PVC insulated multistranded FRLS type unsheathed(Green colour),single core cable with copper conductor cable as earth continuity conductor and connecting to common earth dolly and including making good the disturbed surfaces to match with existing surface and colour shade with putty for smooth finishing one light point controlled by one switch. complete all as specified and directed. (Note:- All necessary accessories such as modular box,top cover plate, blank plate,MS box,screws,washers and all modular electrical fixtures are used same make/brand only and including cutting & chasing work at any height and shall be deemed in to included in quoted rate only.)
All as per item No.63 above one fan point controlled by one switch and one regulator.
All as per item No.63 above one exhaust fan point controlled by one switch .
All as per item No.63 above one 5 pin 6 amps socket point controlled by one 6 amps switch on independent board .
All as per item No.63 above one 5 pin 6 amps socket point controlled by one 6 amps switch on same board .
All as per item No.63 above,but point wiring with 2.5 sqmm and earth conductor of size 2.5 sqmm complete all as specified and directed for one 6 pin 16/6 amps socket outlet point controlled by one 16 amps switch on independent board.
Supply & fixing modular type switch 6 Amps, single pole,1way,1 module,240V,AC, ISI Marked complete all as specified and directed.
Supply & fixing modular type switch 16 Amps, single pole,1way,1 module,240V,AC, ISI Marked complete all as specified and directed.
Supply & fixing modular type socket shuttered type 6 Amps, 2/3 Pin combined 2 module,240V,AC ISI Marked complete all as specified and directed.
Supply & fixing modular type socket 6 A/16 Amps, 6 Pin combined shuttered socket 2 module,240V,AC ISI Marked complete all as specified and directed
Supply & fix angle lamp holder, insulated body with back plate for batten fittings including LED lamp 10 watts complete all as specified and directed.
Supply & fix ceiling rose, 3 terminal ,PVC/polycarbonate body ISI marked, complete all as specified and directed
S&F decorative box type 20 watt light fitting, blue coloured end caps, pre-wired, and including providing PVC/Wooden round/square block -02 Nos and connected with LED fitting to ceiling rose and including LED T-8 tubular lamp of 20 Watt extruded aluminium/PC body and PC diffuser complete with inbuilt LED driver including taking down old unserviceable fitting complete all as specified and directed.
Supply & fixing LED light fitting mirror type with high out put diffuser 2 feet, 10 Watt 220V AC decorative type with driver holder and LED lamp including connecting up with three core flexible copper conductor cable of suitable size complete incl taking down old unserviceable fittings all as speicifed and directed.
S&F round shape 15 W 220 V AC recessed type with high efficiency PMMA diffusers soft glare free light complete with drivers,holding arrangement etc sutable for fixing at roof ceiling including connecting up with three core flexible copper conductor cable complete incl taking down old unserviceable fittings all as directed by Engg in Charge.
Supply & fix TPN distribution board 4 way acrylic door 415 volts AC,TPN for flush mounting with 100 amps copper busbar,neutral bar,earth bar and MCB incomer of rating upto 100 Amps ,MCB SPN/DP, and MCB SP as outgoing and complete connecting cable links with top and bottom removable gland plate with IP 43 DBs protection and including making good the disturbed surfaces to match with existing surface and colour coat including taking down old unserviceable item all as specified and as directed.
Supply & fix SPN double door distribution board 8 way acrylic door 240 volts AC,SPN for flush mounting with 200 amps copper busbar,neutral bar,earth bar and MCB incomer of rating upto 200Amps ,MCB SPN/DP, and MCB SP as outgoing and complete connecting cable links with top and bottom removable gland plate with IP 43 DBs protection and including making good the disturbed surfaces to match with existing surface complete incl taking down old unserviceable fittings all as speicifed and directed.
Supply & fix in repair MCB SP 6 to 32 Amps 10 KA,"B" series, AC, 240Volts, 50Hz , ISI marked complete all as specified and directed.
Supply & fix in repair and MCB SPN 40 to 63 Amps 10 KA,"B" series, AC, 240Volts, 50Hz, ISI marked complete all as specified and directed.
Supply & fix in repair and MCB TPN FP 40 to 100 Amps 10 KA,"B" series, AC, 415Volts, 50 Hz, ISI Marked complete all as specified and directed.
Supply & fix bldc ceiling fan complete with blades,down rod,electronic type regulator(if required) and accessories 230 V,1200 mm sweep.min air delivery 210CFM. BEE 5 star rated.
Supply & fix air circulator fan 230 single single phase oscillating 600 mm sweep suitable for wall mounting all as specified and as directed by Engg in charge.
Supply & fix exhaust fans PVC Body AC ,single phase, 230/ 240 V, of size 250 mm sweep with louver.
Supply and fix flat sleek smooth 25 A motor starter for AC including cutting fixing of concealed MS 2M box with cover and finishing as directed.
Supply and concealed fixing socket 3 pin 25 A for AC including cutting fixing MS 2m box with cover plate including all other necessary items.
M&L for sub main wiring complete with 2 run of 10 sqmm single core copper conductor (ISI marked)cable 1100 volts grade, ISI marked,FRLSH type (conforming to IS-694/1990 as amended) PVC insulated, unsheathed,flexible,multi stranded colour coded cables drawn through and including rigid PVC conduit ISI marked medium grade(MMS) with all connected accessories such as Bend, Tee, Elbow, Short peices etc concealed in wall/roofs/floors and including one run of 10 sqmm single core copper conductor cable flexible, PVC insulated, unsheathed, multistranded, 1100 volts grade, ISI marked, FRLSH type as earth continuity conductor connected to common earth dolly including taking down the old unservicable wiring and including making good the disturbed surfaces to match with existing surface and colour shade and complete all as specified and directed. Note : - Two run of 10 sqmm single core copper conductor cable and one run of 10 sqmm single core copper conductor cable as earth continuity and one run of PVC conduit shall be measured as one unit.
M&L for sub main wiring complete with 4 run of 16 sqmm single core copper conductor (ISI marked)cable 1100 volts grade, ISI marked,FRLSH type (conforming to IS-694/1990 as amended) PVC insulated, unsheathed,flexible,multi stranded colour coded cables drawn through and including rigid PVC conduit ISI marked medium grade(MMS) with all connected accessories such as Bend,Tee,Elbow,Short peices etc concealed in wall/roofs/floors and including two run of 16 sqmm single core copper conductor cable flexible, PVC insulated, unsheathed, multistranded, 1100 volts grade, ISI marked, FRLSH type as earth continuity conductor connected to common earth dolly including taking down the old unservicable wiring and including making good the disturbed surfaces to match with existing surface and colour shade and complete all as specified and directed. Note : - 4 run of 16 sqmm single core copper conductor cable and two run of 16 sqmm single core copper conductor cable as earth continuity and one run of PVC conduit shall be measured as one unit.
M&L for sub main wiring for AC connection complete with 2 run of 4 sqmm single core copper conductor (ISI marked)cable 1100 volts grade, ISI marked,FRLSH type (conforming to IS-694/1990 as amended) PVC insulated, unsheathed,flexible,multi stranded colour coded cables drawn through and including rigid PVC conduit ISI marked medium grade(MMS) with all connected accessories such as Bend,Tee,Elbow,Short peices etc concealed in wall/roofs/floors and including one run of 4 sqmm single core copper conductor cable flexible, PVC insulated, unsheathed, multistranded, 1100 volts grade, ISI marked,FRLSH type as earth continuity conductor connected to common earth dolly including taking down the old unservicable wiring and including making good the disturbed surfaces to match with existing surface and colour shade and complete all as specified and directed. Note : - Two run of 4 sqmm single core copper conductor cable and one run of 4 sqmm single core copper conductor cable as earth continuity and one run of PVC conduit shall be measured as one unit.
Material and labour for Earthing complete with galvanised steel earth plate electrode (600mm x 600mm x 6mm) thick buried directely in ground vertically ( earth pit not less than 2.25 meters deep below ground level) with top edge of plate not less than 1.5 metres below ground level, connected to and including galvanised iron wire 4 mm dia and light grade protection pipe of 15 mm dia from earth electrode up to test point or up to 7.5mtr whichever is less by means of GI bolts, nuts, check nuts and washers all as per electrical plate No 3 of SSR Pt-I and GI watering pipe of 20 mm dia medium grade,GI funnel with wire mesh,including charcoal, salt packed all around the earth electrode plate in layers, PCC earth pit chamber (1:3:6) type C1, of size (45 x 45 x 45 cm), RCC cover (1:2:4) type B1 of size (45 x 45 x 6 cm), excavation/earth work in any strata and returning filling, removal of surplus soil and testing/test point for required value including taking down are removing old item complete all as specified and directed.
M & L for Earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthling etc. as required 4 mm dia galvanised iron or steel wire
Dismantling of ceiling fan,exhaust fan ,wall mounted oscillating fan from any height /location carefully and deposited to MES store for repair and reuse later on complete all as specified and directed by Engg in Charge.
Supply and fix modular metal flush box and modular cover plate with frame of 8 module
Supply and fix modular metal flush box and modular cover plate with frame of 1/2 module
Supply and fix modular metal flush box and modular cover plate with frame of 3 module
Supply and fix surface mounting/hanging type fire exit sign board having rectangular shape of size 18 inch x 6 inch with 11w led light and battery suitable for min 3 hrs battery backup incl fixing arrangement complete all as specified and directed by Engg in Charge. (Make : Prolite/Illumax/Havells/Crompton etc)
Supply and fix 25 W LED strip with driver suitable for fixing at stair, wall etc having size (5000 x 8 x 3) mm complete all as specified and directed by Engr in charge.
Supplying, commissioning, programming and testing of dimming light system of 20W LED recess spot downlighter with Pressure Die Cast Aluminum housing and minimum system lumen output of 2000 lumens with efficacy not less than 100 lm/W complete with necessary wire/cable for ballast & controler internal connection and CAT 6 cable for Key pad connection complete all as specified and directed by Engr in charge . The luminaire should have CCT of 5000 K. The luminaire should have CRI of > 80 . It should have IP20 protection and Operating Temperature range should be 0 to 45 deg C. Operating voltage should be 140 - 270V or in better range. Beam angle of the luminaire should be near the range of 30 to 40 degree. Driver should be of Dimmable type with DALI protocol. Both Luminaire and Driver should be BIS Approved. LM 79 report and Type Test Certificate to be submitted for luminaire and LM 80 report for LED source issued by LED manufacturer.. (Make: Philips Model “RS271B LED20/850 PSD WB WH” or equivalent as approved by GE). Note : - CAT 6 cable shall be measured and paid separately as supply only.
S&F one set 12 x 20A Relays Controller (feed through) General Loading complete for items No. 99 all as specified and directed. This 12 channel devices supports all types of switched loads up to 20 A inductive. The maximum load may be limited by 500 A inrush rating for controlling. (Make: Philips or equivalent as approved by GE)
S&F one set Touch Panel, EU, White facia & Black rim - Custom Labeling - Keypad for controlling scenes / circuits of lights for item No. 99 complete all as specified and directed. (Make: Philips or equivalent as approved by GE)
S&F one set Antumbra Communication module - Communication module for Keypads for controlling dimmable lights for item No. 99 complete all as specified and directed. (Make: Philips or equivalent as approved by GE)
Supply only Cat 6 Cable for item No. 99 complete all as specified and directed. (Make: Philips or equivalent as approved by GE)
Friends Trading Co
Shree Mahabir Builders
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .