Loading…
Loading…
Tender Value
₹45 L
EMD Value
₹45,000
Closing Date
16 Jul 2026, 6:00 pm
Executive Engineer, Ankleshwar Industrial Division Office, DGVCL.
Tenders for ARC work of Laying of underground cable network with terminations for underground work in the area of Ankleshwar Industrial S/Dn & any Other S/Dn under SI & all other scheme jurisdiction of Ankleshawar Industrial Division.
319564
E-27/2025-26
Open
Electrical and Maintenance Works
Bharuch
2 documents required · 2 mandatory
₹1,180
DGVCL ANKLESHWAR IND DIV
₹45,000
1 Jul 2026
1 Jul 2026
1 Jul 2026
16 Jul 2026
1 Jul 2026
Tenders for ARC work of Laying of underground cable network with terminations for underground work in the area
of Ankleshwar Industrial S/Dn & any Other S/Dn under SI & all other scheme jurisdiction of Ankleshawar Industrial
Item Code Item Unit FY 2024-25
HT TAPPING FROM THE EXISTING POLE INCLUDING
FIXING OF CROSS ARMS, CLAMPS ANTI-CLIMBING
DEVICES, DANGER BOARD, INSULATORS ETC. COMPLETE
1 9926000001 AND PAINTING OF FABRICATED MATERIALS AND No.
NUMBERING COMPLETE WITH COST OF PAINTS AS PER
STANDARD SPECIFICATION BUT EXCLUDING ERECTION
OF GUY SET AND EARTHING.
ERECTION OF PSC POLES OF 8 *200 KG INCLUDING
EXCAVATION OF PIT AND REFILLING OF EARTH, FIXING
OFCROSS ARMS, TOP FITTING CLAMPS ANTI-CLIMBING
DEVICES, INSULATORS ETC. COMPLETE AND PAINTING
OF FABRICATED MATERIALS USED ON THE POLES AND
NUMBERING WITH COST OF PAINT AS PER STANDARD
SPECIFICATION BUT EXCLUDING ERECTION OF GUY SET
ERECTION OF STEEL POLES OF 9 TO 11 METERS
INCLUDING EXCAVATION OF PIT AND REFILLING OF
EARTH, FIXING OFCROSS ARMS, TOP FITTING CLAMPS
ANTI-CLIMBING DEVICES, DANGER BOARD, INSULATORS
3 9926000003 ETC. COMPLETE AND PAINTING OF STEEL POLE, No.
FABRICATED MATERIALS USED ON THE POLEAND
NUMBERING WITH COST OF PAINT AS PER STANDARD
SPECIFICATION BUT EXCLUDING ERECTION OF GUY SET
ERECTION OF STEEL POLE OF 13 METERS FOR RAILWAY
CROSSING ON BG/MG/NG LINE FOR 0.400/11/22KV
OVERHEAD LINES I.E INCLUDING EXCAVATION OF PIT &
REFILLING OF EARTH, FIXING CROSS ARMS, TOP FITTING
CLAMPS,ANTI-CLIMBING DEVICES DANGER BOARD,
INSULATORS ETC. COMPLETE AND PAINTING OF STEEL
POLES, FABRICATED MATERIALS USED ON THE POLES
AND NUMBERING WITH COSTOF PAINT AS PER
STANDARD SPECIFICATION BUT EXCLUDING ERECTION
OF GUY SETS AND EARTHING.
ERECTION OF DOUBLE POLE STRUCTURE OF 8 METERS
200 KG PSC POLES INCLUDING EXCAVATION OF PITS &
REFILLING OF EARTHING, FIXING OF CHANNELS,
SUPPORTING ANGLES,CLAMPS, ANTI-CLIMBING DEVICES
5 9926000005 DANGER BOARDS,INSULATORS ETC.COMPLETE AND No.
PAINTING OF FABRICATED MATERIALS USED ON THE
POLES AND NUMBERING WITH COST OF PAINT AS PER
STANDARD SPECIFICATION BUT EXCLUDING ERECTION
OF GUY SETS AND EARTHING.(WITHOUT AB SWITCH)
ERECTION OF DOUBLE POLE STRUCTURE OF 9 TO
METERS.STEEL POLE INCLUDING EXCAVATION OF PITS &
REFILLING OFEARTH, FIXING OF CHANNELS,
SUPPORTING ANGLES, CLAMPS,ANTI-CLIMBING DEVICES
DANGER BOARDS, INSULATORS ETC.COMPLETE &
PAINTING OF POLES,FABRICATED MATERIALSUSED ON
THE POLES AND NUMBERING WITH COST OF PAINTSAS
PER STANDARD SPECIFICATION BUT EXCLUDING
ERECTION OF GUY SET AND EARTHING.(WITHOUT AB
ERECTION OF DOUBLE POLE STRUCTURE WITH
MOUNTING OF AB SWITCH, HG FUSES OF 8 MTRS
KG PSC POLES INCLUDING EXCAVATION OF PITS AND
REFILLING OF EARTH,FIXING OF CHANNELS SUPPORTING
ANGLES, CLAMPS, ANTI-CLIMBING DEVICES, DANGER
7 9926000007 BOARDS, INSULATORS,DOFUSES ETC. COMPLETE AND No.
PAINTING OF FABRICATED MATERIALS USED ON THE
POLES AND NUMBERING WITH COSTOF PAINT AS PER
STANDARD SPECIFICATION BUT EXCLUDINGOF
ERECTION OF GUY SET AND EARTHING.(WITH AB
ERECTION OF DOUBLE POLE STRUCTURE WITH
MOUNTING OF AB SWITCH,HG FUSES, 9 TO 11 METERS
STEEL POLES INCLUDING EXCAVATION OF PITS AND
REFILLING OF EARTH, FIXING OFCHANNEL, SUPPORTING
ANGLES, CLAMPS, ANTI-CLIMBING DEVICES , DANGER
BOARDS, INSULATORS, ETC. COMPLETE AND PAINTING
OF POLES FABRICATED MATERIALS USED ON THE POLES
AND NUMBERING WITH COST OF PAINT AS PER
STANDARD SPECIFICATION BUT EXCLUDING ERECTION
OF GUY SET AND EARTHING.(WITH AB SWITCH)
ERECTION OF DOUBLE POLE STRUCTURES WITH
MOUNTING OFAB SWITCH, HG FUSES,
TRANSFORMERS, LIGHTENING ARRESTORS,
DISTRIBUTION BOX. OF 8 METER,200KG PSC POLE
METERS POLES INCLUDING EXCAVATION OF PITS AND
REFILLING OF EARTH, CARTING OF TRANSFORMERS
FROMSTORES TO SITE, FIXING OF CHANNELS,
SUPPORTING ANGLES,BRACINGS CROSS ARMS CLAMPS,
ANTICLIMBING DEVICES DANGER BOARDS, CONDUCTOR
AND CABLE WIRING ETC.COMPLETE AND PAINTING OF
FABRICATED MATERIALS USEDON THE POLES AND
NUMBERING WITH COST OF PAINT AS PER STANDARD
SPECIFICATION BUT EXCLUDING ERECTION OF GUY SETS
ERECTION OF DOUBLE POLE STRUCTURE WITH
MOUNTING OF AB SWITCH,HG FUSES TRANSFORMERS,
LIGHTENING ARRESTORS, DISTRIBUTION BOX 9 TO
METERS STEEL POLES INCLUDING EXCAVATION OF PITS
& REFILLING OF EARTH CARTING OF TRANSFORMERS
FROM STORE TO SITE, FIXINGOF CHANNELS
SUPPORTING ANGLES, BRACING, CROSS ARMS,CLAMPS,
ANTICLIMBING DEVICES, DANGER BOARDS,CONDUCTOR
AND CABLE WIRING ETC. COMPLETE AND PAINTING OF
POLES FABRICATED MATERIALS USED ON THE POLES
AND NUMBERING AS PER STANDARD SPECIFICATION
BUT EXCLUDING ERECTIONS OF GUY SETS AND
ERECTION OF GUY SET INCLUDING EXCAVATION OF PITS
& REFILLING OF EARTH AS PER STANDARD
SPECIFICATION WITH STAY CLAMPS, STAY WIRE,
ANCHOR ROD, TURN BUCKLE, EYEBOLT, GUY INSULATOR,
CEMENT CONCRETE BLOCK ETC. BUT EXCLUDING
CONCRETING OF POLES, GUYS, ETC. INCLUDING COST OF
CEMENT SAND METAL (1:2:4) AND WATER ETC. AS PER
STANDARD SPECIFICATION.(cement Should be 53 grade)
used for Concreting.
ERECTION OF COIL TYPE EARTHING INCLUDING COST OF
13 9926000013 COAL,SALT ETC. BUT WITHOUT COST OF GI WIRE AS PER No.
STANDARD SPECIFICATION(20kg solt+20kg coal)
ERECTION OF GI PIPE/CI PLATE TYPE EARTHING
INCLUDINGCOST OF COAL SALT ETC. BUT WITHOUT
COST OF PIPE/GIPLATE GI WIRE AS PER STANDARD
SPECIFICATION.(20kg solt+20kg coal)
ERECTION OF STREET LIGHT FIXTURE COMPLETE WITH
CLAMPS, BRASS NIPPLE, BRASS HOLDER TECK WOOD
15 9926000015 BUSH,REFLECTORS FUSE, WIRING ETC. AS PER No.
STANDARD SPECIFICATION BUT EXCLUDING COST OF
STRINGING OF(30mm2)ACSR/34MM@,55MM2 AAA
CONDUCTOR for ALL TYPE OF CONDUCTOR (EXCEPT ONE COND PER
DOG CONDUCTOR) FOR 11/22KV & LT LINES INCLUDING KM
FIXING OF INSULATORS, BINDING JUMPERING ETC.
STRINGING OF GI WIRE 8 SWG INCLUDING BINDING
PROVIDING SINGLE PHASE SERVICE CONNECTION WITH
PVC 2.5/4MM2 TWIN CORE CABLE FROM TERMINAL
POLE TO METERING POINT INCLUDING FIXING OF
METER WITH METER EARTHING COMPLETE WORK AS
PER STANDARD SPECIFICATION BUT EXCLUDING COST
PROVIDING THREE PHASE 4 WIRE SERVICE CONNECTION
WITH PVC 4MM2/10MM2 FOUR CORE CABLE FROM
TERMINAL POLE TO METERING POINT INCLUDING
FIXING OF METER WITH METER EARTHING COMPLETE
WORK AS PER STANDARD SPECIFICATION BUT
EXCLUDING COST OF MATERIALS.
ADDITIONAL COST FOR EXCAVATION OF PIT IN HARD
ROCK AREA FOR ERECTION OF POLE/ GUY ETC. AS PER
STANDARD SPECIFICATION OVER & ABOVE NORMAL
20 9926000020 COST COVERED AGAINST EXCAVATION OF PIT UNDER No.
NORMAL SOIL FOR ERECTION OF POLE,GUY, DOUBLE
POLE STRUCTURE EARTHING WITH THE APPROVAL OF
SUPDT.ENGINEER.
PROVIDING GUARDING TO HT LINE ON ROAD/ RAIL
PROVIDING GUARDING OF LT LINES ON ROAD/RAIL
23 9926000023 LT LINE TAPPING- SINGLE PHASE No.
24 9926000024 LT LINE TAPPING- THREE PHASE No.
Stringing/LAYING OF OVER HEAD LT CABLE FOR ROAD
25 9926000025 CROSSING,HT LINE CROSSING AND TELEPHONE LINE No.
CROSSING ETC.(PER SPAN)
ERECTION OF SINGLE POLE STRUCTURES WITH , HG
FUSES,TRANSFORMERS, LIGHTENING ARRESTOR,
DISTRIBUTION BOX. ON 8 METERS 200 KGAND PSC POLE
INCLUDING EXCAVATION OF PITS AND REFILLING OF
EARTH, CARTING OF TRANSFORMERS FROM STORES TO
SITE, FIXING OF CHANNELS, SUPPORTING
26 9926000026 ANGLES,BRACINGS CROSS ARMS CLAMPS, No.
ANTICLIMBING DEVICES DANGER BOARDS, CONDUCTOR
AND CABLE WIRING ETC.COMPLETE AND PAINTING OF
FABRICATED MATERIALS USED ON THE POLE AND
NUMBERING WITH COST OF PAINT AS PER STANDARD
SPECIFICATION BUT EXCLUDING ERECTION OFGUY SETS
ERECTION OF SINGLE POLE STRUCTURES WITH
MOUNTING OFAB SWITCH , HG FUSES,TRANSFORMERS,
LIGHTENINGARRESTOR, DISTRIBUTION BOX. ON 9 to
11 METERS RSJ POLE INCLUDING EXCAVATION OF PITS
AND REFILLING OF EARTH, CARTING OF TRANSFORMERS
FROM STORES TO SITE, FIXING OF CHANNELS,
27 9926000027 SUPPORTING ANGLES,BRACINGS CROSS ARMS CLAMPS, No.
ANTICLIMBING DEVICES DANGER BOARDS, CONDUCTOR
AND CABLE WIRING ETC.COMPLETE AND PAINTING OF
FABRICATED MATERIALS USED ON THE POLE AND
NUMBERING WITH COST OF PAINT AS PER STANDARD
SPECIFICATION BUT EXCLUDING ERECTION OFGUY SETS
ERECTION OF PSC POLES OF 10 *270 KG INCLUDING
EXCAVATION OF PIT AND REFILLING OF EARTH, FIXING
OF CROSS ARMS, TOP FITTING CLAMPS ANTI-CLIMBING
DEVICES, INSULATORS ETC. COMPLETE AND PAINTING
OF FABRICATED MATERIALS USED ON THE POLES AND
NUMBERING WITH COST OF PAINT AS PER STANDARD
SPECIFICATION BUT EXCLUDING ERECTION OF GUY SET
ERECTION OF DOUBLE POLE STRUCTURE OF 10 METERS
270 KG PSC POLES INCLUDING EXCAVATION OF PITS &
REFILLING OF EARTHING, FIXING OF CHANNELS,
SUPPORTING ANGLES,CLAMPS, ANTI-CLIMBING DEVICES
29 9926000029 DANGER BOARDS,INSULATORS ETC.COMPLETE AND No.
PAINTING OF FABRICATED MATERIALS USED ON THE
POLES AND NUMBERING WITH COST OF PAINT AS PER
STANDARD SPECIFICATION BUT EXCLUDING ERECTION
OF GUY SETS AND EARTHING.(WITHOUT AB SWITCH)
STRINGING OF 100MM2 ACSR/100MM2 AAAC
30 9926000030 CONDUCTOR FOR 11/22KV & LT LINES INCLUDING
FIXING OFINSULATORS, BINDING JUMPERING ETC.
STRINGING OF DOG CONDUCTOR FOR 11/22KV & HT
31 9926000031 LINES INCLUDING FIXING OF INSULATORS, BINDING
ERECTION OF DOUBLE POLE STRUCTURES WITH
MOUNTING OF AB SWITCH, HG FUSES,
TRANSFORMERS, LIGHTENING ARRESTORS,
DISTRIBUTION BOX. OF 10 METERS 270 KGAND PSC
POLES INCLUDING EXCAVATION OF PITS AND REFILLING
OF EARTH, CARTING OF TRANSFORMERS FROMSTORES
TO SITE, FIXING OF CHANNELS, SUPPORTING
ANGLES,BRACINGS CROSS ARMS CLAMPS,
ANTICLIMBING DEVICES,DANGER BOARDS, CONDUCTOR
CABLE WIRING ETC.COMPLETE AND PAINTING OF
FABRICATED MATERIALS USED ON THE POLES AND
NUMBERING WITH COST OF PAINT AS PER STANDARD
SPECIFICATION BUT EXCLUDING ERECTION OF GUY SETS
DISMENTALLING OF 8 MTR PSC POLE WITH CREDITING
OF FABRICATION AT STORE & STACKING OF POLE SAFELY
ON ROAD SIDE OR CREDITING TO DEPARTMENTAL
DISMENTALLING OF 10 MTR PSC POLE WITH CREDITING
OF FABRICATION AT STORE & STACKING OF POLE SAFELY
ON ROAD SIDE OR CREDITING TO DEPARTMENTAL
DISMENTALLING OF TRANSFORMER CENTRE (8 MTR PSC
35 9926000035 POLE) (WITH TRANSFORMER) WITH CREDITING OF No.
FABRICATION & TRANSFORMER AT STORE & STACKING
OF POLE SAFELY ON ROAD SIDE OR CREDITING TO
DEPARTMENTAL STORE
DISMENTALLING OF TRANSFORMER CENTRE (8 MTR PSC
POLE) (WITHOUT TRANSFORMER) WITH CREDITING OF
36 9926000036 FABRICATION AT STORE & STACKING OF POLE SAFELY No.
ON ROAD SIDE OR CREDITING TO DEPARTMENTAL STORE
STRINGING OF LT ABC OF 1*35 SQ MM + 1*25 SQ MM
INCLUDING FITTING OF ALL ACESSARIES I.E. SPECIAL
DESIGN SUSPENSION / TENSION CLAMP, FIXING OF
CROSS ARM, LT SHACKLE INSULATOR ETC. FOR FIXING
37 9926000037 OF MESSENGER WIRE AND TO PROVIDE SERVICE KM
CONNECTION ON AERIAL BUNCH CABLE BY INSULATED
PIERCEING CONNECTORS THROUGH SERVICE
CONNECTION BOX COMPLETE AS REQUIRED & DIRECTED
BY ENGINEER IN CHARGE.
STRINGING OF LT ABC OF 3*50 SQ MM +1*25 SQ
MM+1*35 SQ MM INCLUDING FITTING OF ALL
ACESSARIES I.E. SPECIAL DESIGN SUSPENSION / TENSION
CLAMP, FIXING OF CROSS ARM, LT SHACKLE INSULATOR
38 9926000038 ETC. FOR FIXING OF MESSENGER WIRE AND TO KM
PROVIDE SERVICE CONNECTION ON AERIAL BUNCH
CABLE BY INSULATED PIERCEING CONNECTORS
THROUGH SERVICE CONNECTION BOX COMPLETE AS
REQUIRED & DIRECTED BY ENGINEER IN CHARGE.
STRINGING OF 11KV ABC OF 3*95 SQ MM +80 SQ MM
INCLUDING FITTING OF ALL ACESSARIES I.E. SPECIAL
DESIGN SUSPENSION / TENSION CLAMP, FIXING OF
CROSS ARM, BINDING TO PIN INSULATOR,PREPARING
SHACKLE POINT,JUMPERS ETC. AS REQUIRED &
DIRECTED BY ENGINEER IN CHARGE
STRINGING OF 22 KV ABC OF 3*70 SQ MM +95 SQ MM
INCLUDING FITTING OF ALL ACESSARIES I.E. SPECIAL
DESIGN SUSPENSION / TENSION CLAMP, FIXING OF
CROSS ARM, BINDING TO PIN INSULATOR,PREPARING
SHACKLE POINT,JUMPERS ETC. AS REQUIRED AND
DIRECTED BY ENGINEER IN CHARGE
STRINGING OF LT ABC OF 2*50 SQ MM +1*25 SQ MM+
35 SQ MM INCLUDING FITTING OF ALL ACESSARIES I.E.
SPECIAL DESIGN SUSPENSION / TENSION CLAMP, FIXING
OF CROSS ARM, LT SHACKLE INSULATOR ETC. FOR
41 9926000041 FIXING OF MESSENGER WIRE AND TO PROVIDE SERVICE KM
CONNECTION ON AERIAL BUNCH CABLE BY INSULATED
PIERCEING CONNECTORS THROUGH SERVICE
CONNECTION BOX COMPLETE AS REQUIRED & DIRECTED
BY ENGINEER IN CHARGE.
DISMENTALING OF RSJ (9/11 METER) POLE AND
CREDITING THE OLD MATERIAL TO STORE
DISMENTALING OF TRANSFORMER CENTER ON
10MTR,270KG PSC POLE(WITHOUT TRANSFORMER)
43 9926000043 WITH CREDITING OF FABRICATION AT STORE AND No.
STACKING OF POLE SAFELY ON ROAD SIDE OR
CREDITING TO DEPARTMENTAL STORE
DISMENTALING OF TRANSFORMER CENTER ON
10MTR,270KG PSC POLE(WITH TRANSFORMER) WITH
44 9926000044 CREDITING OF FABRICATION AT STORE AND STACKING No.
OF POLE SAFELY ON ROAD SIDE OR CREDITING TO
DEPARTMENTAL STORE
DISMENTLING OF 11KV ABC OF 3*95 SQ MM +80 SQ
45 9926000045 MM AND CREDITING FITTING OF ALL ACESSARIES AND KM
FABRICATION TO DEPARTMENTAL STORE
DISMENTLING OF 22 KV ABC OF 3*70 SQ MM +95 SQ
46 9926000046 MM AND CREDITING FITTING OF ALL ACESSARIES AND KM
FABRICATION TO DEPARTMENTAL STORE
DISMENTALING OF LT ABC OF 1*35 SQ MM + 1*25 SQ
47 9926000047 MM AND CREDITING FITTING OF ALL ACESSARIES TO KM
DEPARTMENTAL STORE.
DISMENTALING OF LT ABC OF 3*50 SQ MM +1*25 SQ
48 9926000048 MM+1*35 SQ MM AND CREDITING FITTING OF ALL KM
ACESSARIES TO DEPARTMENTAL STORE.
DISMENTALING OF LT ABC OF 2*50 SQ MM +1*25 SQ
49 9926000049 MM+ 35 SQ MM AND CREDITING FITTING OF ALL KM
ACESSARIES TO DEPARTMENTAL STORE.
RESTRINGING OF ALL TYPE OF CONDUCTOR (EXCEPT
50 9926000050 DOG CONDUCTOR) FOR 11/22KV & LT LINES INCLUDING
FIXING OF INSULATORS, BINDING JUMPERING ETC.
RESTRINGING OF DOG CONDUCTOR FOR 11/22KV HT ONE COND PER
LINES INCLUDING , BINDING JUMPERING ETC. KM
LABOUR CHARGE FOR THE INSTALLATION OF NEW DTR
METER. (METER WILL BE PROVIDED BY DGVCL)
LABOUR CHARGE FOR THE REPLACEMENT OF DTR
53 9926000053 METER AND OLD METER SHOULD BE CREDITED TO SDN No.
STORE. (METER WILL BE PROVIDED BY DGVCL)
LABOUR CHARGE FOR PROVIDING CT COIL FOR DTR
54 9926000054 METER CONNECTION. (CT COIL WILL BE PROVIDED BY PER CT
LABOUR CHARGE FOR REPLACEMENT OF CT COIL FOR
DTR METER CONNECTION AND OLD CT SHOULD BE
CREDITED TO SDN STORE. (CT COIL WILL BE PROVIDED BY
LABOUR CHARGE FOR FIXING OF MMB FOR DTR METER
(MMB WILL BE PROVIDED BY DGVCL)
LABOUR CHARGE FOR REPLACEMENT OF DTR METER
BOX. (METER WILL BE PROVIDED BY DGVCL)
PROVIDING / REPLACEMENT OF 1.5 SQ MM 10 CORE
58 9926000058 COPPER CABLE 3.5 METER (CABLE TO BE PROVIDED BY No.
LABOUR CHARGE FOR PROVIDING/RECONNECTION OF
59 9926000059 TERMINAL CONNECTION WITH PROPER SIZE OF LUGS.
(LUGS COST IS BORNE BY AGENCY)
LABOUR CHARGE FOR THE SPOT READING OF DTR
METER WITH DETAIL SURVEY OF DEFECT IF ANY. A DULY
SIGN COPY BY SURVEYOR PERSON OF AGENCY IN
60 9926000060 PROFORMA REPORT SHOULD BE SUBMITTED TO SDN PER DTR
OFFICE.(* ONLY IF ALL PARAMETER OF VOLTAGE,
CURRENT & LOAD AS SHOWN IN PER-FORMA IS FILLED)
AS PER THE INSTRUCTION OF ENGINEER IN-CHARGE.
LABOUR CHARGE FOR THE SPOT READING OF DTR
METER WITH DETAIL SURVEY OF DEFECT IF ANY. A DULY
SIGN COPY BY SURVEYOR PERSON OF AGENCY IN PRO-
FORMA REPORT SHOULD BE SUBMITTED TO SDN
OFFICE. (DULY FILL PER-FORMA IN FAULT CONDITION IN
WHICH READING PARAMETER IS NOT SHOWN IN METER)
INSTALLATION OF DTR METER INCLUDING METER BOX,
PROVIDING & FIXING OF 1.5SQ MM SINGLE STRAND
62 9926000062 CORE ARMOURED COPPER CABLE (3.5METER), No.
TERMINATION IN METER & COIL ETC.(METER, METER
BOX, C.T./P.T. COIL WILL BE PROVIDED BY DGVCL)
INSTALLATION OF DTR METER INCLUDING METER BOX,
TERMINATION IN METER & COIL ETC. (WITHOUT
10CORE COPPER CABLE) (METER, METER BOX, C.T./P.T.
COIL WILL BE PROVIDED BY DGVCL)
Binding of messanger Conductorat with a distance not
more than 0.75 mtr with 6 turns minimum on XLPE Cable
with single strand binding wire (including cost of binding
Supply and Installation of 11/22 kV Distribution
Transformers HT Terminal protector (UV Resistance) with
using 95/120/150 sq.mm long barrel aluminum lug.
(1Set = 3 Nos i.e. on R, Y, B)
Supply & Installation of HT EPR Tap on 11/22 kV
Distribution Transformer with replacement of bare
conductor by HT ABC conductor (DO bottom side to
transformer) after removal of semi conductor by HT ABC
(6 inch both side). HT ABC to be supplied by DGVCL.
(1Set = 3 Nos i.e. on R, Y, B)
Supply, Installation, Testing and Commissioning of
Maintenance Free, Ready Capsule, Pipe-In-Cage (Pic)
67 9926000088 Type, Earth Electrodes for HT Feeder Pole Having 2000 NO
mm Electrode Length as per the Tender Specifications
and Drawing. (All Materials Will Be Supplied By Agency)
Supply, Installation, Testing and Commissioning of
Maintenance Free, Ready Capsule, Pipe-In-Cage (Pic)
68 9926000089 Type, Earth Electrodes for HT Feeder Pole Having 3000 NO
mm Electrode Length as per the Tender Specifications
And Drawing. (All Materials Will Be Supplied By Agency)
Supply and Installation of 25 X 3 mm GI Strip having hot
dip- galvanized-zinc coating of 80-100 microns without
any joints or welding. Both the end of the GI strip should
be connected with GI nut bolts and required fabrication
work for giving separate earthing connections to
69 9926000090 (1) Neutral of the transformer Meter
(2) MS structures of the transformer center
(Approximately 25 meter GI strip per transformer centre -
as per requirement and instruction of Engineer in-
charge) (All Materials will be supplied by Agency)
Supply and Installation of uPVC standard make Pipe of
1.25" diameter for covering GI strip with UV protected
Cable Ties of 550 X 7.6 mm size to bind with pole
face(Approximately 25 meter uPVC pipe for GI strip
covering per transformer centre -as per requirement and
instruction of Engineer in-charge.
Supply & fixing of upto 33 kV Conducotr sleev for Busbar
to Drop out Fuse and Drop out fuse to Transformer H.T.
including Busbar (12 mm sleev) as per technical
specification. (All Materials will be supplied by Agency)
Supply & fixing of upto 33 kV Conducotr sleev for Busbar
to Drop out Fuse and Drop out fuse to Transformer H.T.
including Busbar(15 mm sleev) as per technical
specification. (All Materials will be supplied by Agency)
Supply & fixing of Disc type Red Color FRP(Nonflammable)
material with Weather resistant, Nonconductive bird
73 9926000095 guard OD=300 MM, ID=33 MM, Width =1.25 MM, one NO
side cut from ID to OD. (All Materials will be supplied by
Providing and fixing of LT Terminal protectors i.e.
Reuseable boot (LT Side 1.1 kV) including LT (1.1 kV)
insulating taps. All live part at LT side shall be covered
with fixing of LT insulating taps.
75 Nylon Net around Transformer Center
76 9926000097 Nylon Net (12 * 15 ft) Per Net
77 9926000098 Nylon Dori Per TC
Labour charge for fitting Nylon Net (All fabricated
78 9926000099 material for fitting nylon net shall be provided by DGVCL) Per TC
79 9924000001 Cutting of Tree branches surounding HT/LT line Per Tree
Replacement of old jumpers & providing new double
80 9924000002 jumpers with 8" binding [D Type] & capsuling with PVC No.
81 9924000005 Support pole for Stay PSC/STP/RSJ No.
82 9924000006 Pin binding of conductor 11/22kv Pin insulator No.
Pin binding of conductor 11/22kv Pin insulator per pole in
costle area with cleaning .
84 9924000008 Pin binding of conductor LT shakel insulator No.
85 9924000009 Replacement of one/both disc.insulator at strain pole No.
86 9924000010 Replacement of LT shackle insulator at cut point No.
87 9924000011 Refixing of V cross Arm No.
Replacement of V cross Arm (With Transportation &
89 9924000013 Refixing of Top fitting in proper position No.
90 9924000014 Replacement of Top fitting No.
91 9924000015 Replacement of LT cross Arm No.
Providing DO fuse on DP with carting & jumpuring(ONE
Numburing of pole with paint by preparing back ground
93 9924000017 of one colour and have lettering(height 3" * width 0.5") No.
94 9924000018 Fixing of MMB(1PH.) at consumer end No.
95 9924000019 Fixing of MMB(3PH.) at consumer end No.
96 9924000020 Replacement of (1ph.) meter for Urban area No.
97 9924000021 Replacement of (1ph.) meter for Rural area No.
painting consumer no. on MMB (Urban) (with letter size
height 40mm* width 8mm)
painting consumer no. on MMB (Rural) (with letter size
height 40mm* width 8mm)
100 9924000024 Replacement of deteriorated Single phase Service line No.
Fixing of new dist. Box with complete wiring including
clamps,nut bolts etc.
Reparing of guarding involving reshaping of bearer wire
cross lacing binding etc.
Painting of steel fabricated material of RSJ DO DP
structure with paint
Painting of steel fabricated material of RSJ pole mounted
transformer double pole structure with paint
Painting of steel fabricated material of RSJ single pole
painting of steel fabricated material of PSC Single pole
(HT line) with paint
painting of steel fabricated material of PSC DO DP double
pole with paint
painting of steel fabricated material of PSC double pole
at pole mounted transformer with paint
109 9924000033 Providing line seperater single phase No.
110 9924000034 Providing line seperater three phase No.
Replacement / Providing of stay insulator along with
adjustment of tension in stay wire
Replacement of deteriorated /providing LT dist. Box with
new up to 100KVA capacity & crediting it to store.
Replacement of deteriorated /providing LT dist. Box with
new above 100KVA capacity & crediting it to store.
114 9924000038 Adjustment of tension in stay wire No.
115 9924000039 Refitting of LA No.
Converting pin point to Shackle point including
116 9924000040 location
dismentaling & restringing etc.
replacement of 11KV Pin insulator with providing new
double pin binding
replacement of 22KV Pin insulator by new 11kv pin
118 9924000042 insulator with spares & providing new double pin binding No.
Providing 11kv double disc insulators with binding &
Replacement of existing 11kv conductor (all size) with
new double pin binding
121 9924000046 Plumbing of PSC Pole with straightening at pin point No.
122 9924000047 Plumbing of PSC Pole with straightening at tension point No.
Plumbing of tilted DP structure (PSC/RSJ/STP) with
refilling of stone Murrum etc.
Providing new 11kv AB /GO switch with fabrication and
insulated colour code jumper, binding, lugs etc
Replacement of old 11kv AB /GO switch with providing
new insulated jumper, binding, lugs etc
Providing cage type loop guard in verticle LT line with
126 9924000052 per pole
using PVC reel insulators etc
Labour charges for replacement /providing of MMB &
service with all accessories for three phase connection
Labour charges for replacement /providing of MMB &
service with all accessories for single phase connection
Dismentalling of existing Dist.X'mer center(RSJ /STP POLE)
129 9924000055 25/63/100/200 KVA with all fabrication & creditig the old No.
material to store
130 9924000056 Disconnection from LT pole 1 phase No.
Reconnection from LT pole 1 phase
( payment after receipt of R/C charges)
132 9924000058 Disconnection from LT pole 3 phase No.
Reconnection from LT pole 3 phase
( payment after receipt of R/C charges)
Dismentaling & removing of service line from pole &
crediting to S/dn (1 ph.)
Dismentaling & removing of service line from pole &
crediting to S/dn (3 ph.)
Reconnection of service line complete with PVC cable
Reconnection of service line complete with PVC cable (3
Providing spiral type earthing by G.I. NO 8(weight 2kg
5mtr in length) with salt and coal 10kg each, including pvc
138 9924000064 rigid pipe 20mm dia( 1.5mtr length) to pass exposed part No.
of G.I. wire at consumer end with all materials, earth
resistance should be less than 2 ohms
Providing and fixing of signle core 1.5 sq mm single strand
copper insulated cable with cable nail clip for spiral type
earthing at consumer end. The end of G.I. no 8 is to be
connected by connector with copper cable of which other
139 9924000070 per meter
end shall be connected to the earth terminal of meter
box. This item shall be used in location where there is
more distance between earth terminal and earthing
terminal of meter. (All materials supplied by contractor)
Stringing of LT ABC of 1*35 SQ MM + 1*25 SQ MM
including fitting of all acessaries i.e. special design
suspension / tension clamp, fixing of cross arm, LT shackle
insulator etc. for fixing of messenger wire and inclusive of
dismantling charge of existing bare conductor and
crediting in to store & dismentaling of
service line from LT bare conductor and to provide service
connection on Aerial Bunch Cable by insulated pierceing
connectors through service connection box complete as
required & directed by Engineer in Charge.
Stringing of LT ABC of 3*50 SQ MM +1*25 SQ MM+1*35
SQ MM including fitting of all acessaries i.e. special design
suspension / tension clamp, fixing of cross arm, LT shackle
insulator etc. for fixing of messenger wire and inclusive of
dismantling charge of existing bare conductor and
crediting in to store & dismentaling of service line from LT
bare conductor and to provide service connection on
Aerial Bunch Cable by insulated pierceing connectors
through service connection box complete as required &
directed by Engineer in Charge.
Stringing of 11KV ABC of 3*95 SQ MM +80 SQ MM
including fitting of all acessaries i.e. special design
suspension / tension clamp, fixing of cross arm, binding to
142 9924000067 pin insulator,preparing shackle point,jumpers etc. and KM
inclusive of dismantling charge of existing bare
conductor and crediting in to store complete as required
& directed by Engineer in Charge
Stringing of 22 KV ABC OF 3*70 SQ MM +95 SQ MM
including fitting of all acessaries i.e. special design
suspension / tension clamp, fixing of cross arm, binding to
143 9924000068 pin insulator,preparing shackle point,jumpers etc. and KM
inclusive of dismantling charge of existing bare
conductor and crediting in to store complete as required
& directed by Engineer in Charge
Stringing of LT ABC of 2*50 SQ MM +1*25 SQ MM+ 35 SQ
MM including fitting of all acessaries i.e. special design
suspension / tension clamp, fixing of cross arm, LT shackle
insulator etc. for fixing of messenger wire and inclusive of
dismantling charge of existing bare conductor and
crediting in to store & dismentaling of service line from LT
bare conductor and to provide service connection on
Aerial Bunch Cable by insulated pierceing connectors
through service connection box complete as required &
directed by Engineer in Charge.
Labour charge for excavation of cable trench of 400mm
width x 1200mm depth, in any type of soil for laying of
1 9925000001 cable of size up to 240 mm2 (For additional cable 200 mm Meter
additional width shall be considered i.e. half trench length
is to be considered)
Labour charge for excavation of cable trench of 600mm
width x 1200mm depth, in any type of soil for laying of
2 9925000002 cable of size up to 240 mm2 (For additional cable 200 mm Meter
additional width shall be considered i.e. half trench length
is to be considered)
Labour charge for excavation of cable trench of 400mm
width x 1500mm depth, in any type of soil for laying of
3 9925000003 cable of size up to 240 mm2 (For additional cable 200 mm Meter
additional width shall be considered i.e. half trench length
is to be considered)
Labour charge for laying of 11kV / 22 kV XLPE Cable of
size up to 240 mm2 & preparation of sand layer 100mm
thick, in the cable trench & covering the cable with
mm dia (Inner), thickness 25 mm, 1.0 meter long RCC
4 9925000004 half round muffs and providing and fixing of 4inch width Meter
yellow colour polyethylene tape with printing "CAUTION
ELECTRIC CABLE BELOW" at 0.75 m depth from ground
surface after laying cable in trench. This will provide
indication that electric cable is passing underground so
as to protect cable from mechnical injuries, refilling the
same, as per Instruction of Engineer in Charge (EIC).
Labour charge for horizontal drilling using Auger
machine without damage to surface road at max 2.0 mtrs
depth & putting of 6.11 kg/cm2 , class-4,Green color,
110mm O.D. , 8.5mm thickness H.D.P.E. pipe confirms to
IS 4984-1987(3rd revision) and BIS certification and laying
of 11KV/22KV XLPE cable of size up to 240 mm2 in HDPE
5 9925000005 pipe, as per Site Condition (excluding cost of pipe). The Meter
detail map obtained from HDD machine and excell
sheet(hard and soft copy) indicating the respective depth
and distance from adjacent landmark for each segment
for HDD is must required to be submitted. HDD to be
carried out at depth 1.5 mtrs to 2.0 mtrs as per site
conditions and as per instruction of EIC.
Labour charge for horizontal drilling manually without
damage to surface road at max 2.0 mtrs depth & putting
of 6.11 kg/cm2 , class-4,Green color, 110mm O.D.
8.5mm thickness H.D.P.E. pipe confirms to IS
49841987(3rd revision) and BIS certification and laying of
11KV/22KV XLPE cable of size up to 240 mm2 size, as per
Site Condition (excluding cost of pipe). The detail map
and excell sheet(hard and soft copy) indicating the
respective depth and distance from adjacent landmark
for each segment of cable to be submitted. Drilling to be
carried out at depth Minimum 1.2 mtrs to 2.0 mtrs as per
site conditions as per instruction of EIC.
Supply of 6.11kg/cm2 , class-4,Green color, 110mm O.D.
, 8.5 mm thickness H.D.P.E. pipe confirms to IS 4984 and
BIS certification for laying of underground 11KV / 22KV
XLPE cable up to 240 mm2 size.
Labour work for RCC concreting on disputed location and
repairing of damage portion of road crossing for the work
carried out for roads crossing as well as concreting &
muffing of ploes including all materials (1:2:4)
Providing & fixing concrete stone route marker of
mm width x 150 mm thick x 650 mm height embedded in
earth at least 300 mm below & 350 mm above ground
level respectively at distance approx 50 meters along the
length of cable. The RCC concreting (1:2:4)(all necessary
maeterials will be in bidder's scope) of route marker is to
be carried out 300 mm width x 150 mm thick x 300 mm
9 9925000009 below ground level as per instruction of EIC. The route No.
marker should be with name of company with approved
yellow colour-DGVCL. The distance from marker to cable
and cable depth with feeder name etc., marked with
arrow sign is to be painted on it.The route marker is to be
fixed at location near to any fixed permanent location
(not necessary to fix exact on top of cable) as per
instruction of EIC.
Erection of D.P. (double pole) structure using 9 / 11 Mtr.
RSJ pole with cable connection arrangement along with
10 9925000010 fitting of necessary fabrication for 11KV cable including No.
excavation of pit & refilling of earth as per instruction of
EIC. (Exclusive of concreting & muffing of poles)
Erection of Single pole structure using 9 / 11 Mtr RSJ
pole with cable connection arrangement along with
fitting ofnecessary fabrication for 11KV/22 KV cable
including excavation of pit & refilling of earth as per
instruction of EIC. (Exclusive of concreting & muffing of
Erection of D.P. (double pole) structure using 8.0 Mtr.
PSC pole with cable connection arrangement along with
12 9925000012 fitting of necessary fabrication for 11KV cable including No.
excavation of pit & refilling of earth as per instruction of
EIC. (Exclusive of concreting & muffing of poles)
Erection of Single pole structure using 8.0 Mtr PSC pole
with cable connection arrangement along with fitting
13 9925000013 ofnecessary fabrication for 11KV/22 KV cable including No.
excavation of pit & refilling of earth as per instruction of
EIC. (Exclusive of concreting & muffing of poles)
Labour charge for erecting of 11kV / 22 kV XLPE cable of
size up to 240 mm2 on DP Structure with fixing of 02 Nos
polymer cleats on top and middle part.Polymer cleats,
nut bolts etc. fixing material to be provided by contractor.
Providing & fixing of 6.11kg/cm2 , class-4,Green color,
110mm O.D. , 8.5mm thickness H.D.P.E. pipe confirms to
IS 4984 and BIS certification on the erected DP structure
for the mechanical protection of cable by inserting the
15 9925000015 cable inside HDPE pipe. The HDPE pipe shall be erected in Per Job
such a way that 300mm shall be below the ground level
and the rest 2700 mm shall be supported on the DP
Structure with 01 No Polymer cleat.All materials including
polymer cleat and Nut bolt to be provided by contractor.
Providing and fixing of pipe type earthing from 80 mm
dia class-B GI pipe with pit to be filled with salt & coke
and construction of chamber as per DGVCL Drg. No. dg
/100 for DP and cable. The earthing pit should be joined
with cable by G.I. strip of size 1” width & 2 mm thick. All
material GI pipe, Coke, Salt etc will be supplied by bidder.
Supply & fixing of heat shrink type end terminations
17 9925000017 (outdoor) for upto 11kV 3C x 185 mm2 size XLPE cable as No.
per DGVCL technical specification
Supply & fixing of heat & shrinkable end terminations
18 9925000018 (outdoor) for upto 22 kV 3C x 185 mm2 size XLPE cable as No.
per DGVCL technical specification)
Supply & fixing of heat shrink type end terminations
19 9925000019 (indoor) for upto 11kV 3C x 185 mm2 size XLPE cable as No.
per DGVCL technical specification)
Supply & fixing of heat & shrinkable end terminations
20 9925000020 (indoor) for upto 22 kV 3C x 185 mm2 size XLPE cable as No.
per DGVCL technical specification
Supply & fixing of heat shrinkable straight through joint
21 9925000021 for upto 11kV 3C x 185 mm2 size XLPE cableas per DGVCL No.
technical specification.
Supply & fixing of heat shrinkable straight through joint
22 9925000022 type for upto 22kV 3C x 185 mm2 size XLPE cable as per No.
DGVCL technical specification
Labour charge for excavation of 2100mm long x
1200mm wide x 1200 mm deep joint pits for installation of
11kV / 22kV Straight through joints as per instruction of
engineer-in-charge & covering the cable with 150 mm dia
(Outer), thickness 25 mm, 1.0 meter long RCC half round
muffs & refilling same as per instruction of EIC .
Providing and fixing of insulating bus bar, made from
11KV/22KV XLPE cable after removal of semi conducting
layer and applying of PVC heat shrinkable anti-tracking
core insulating tubing (1.1KV), on both end terminal using
Aluminium long barrel heavy duty up to 240 sq mm lugs,
24 9925000024 Aluminium bus connector. Taping with PG- clamp for bus No.
conductor as per drawing and as per instruction of EIC.
The Alluminium lugs and PG clamp shall be covered with
11KV/22KV HT insulating tapes.(11KV/22KV XLPE cable
will be in scope of DGVCL while all other materials will be
in bidder's scope)
Testing of cable at various points and commissioning the
25 9925000025 feeder as per instruction of engineer-in-charge.Test result No.
shall be submitted by contractor with bill.
Preparation and submission of 6 (six) copies, of complete
layout drawings with GIS mapping as per actual cable
routing showing road crossing, HDPE pipe sleeving,
jointing locations, markers etc.
Providing and fixing of Sign Board at junction point
Made out of 2 mm aluminium sheet size 750x300 mm
(2.5 x 1ft) rectangle, as per design, pre treated with
phosphate process and acid etching coated with one coat
of epoxy primer and two coats of best quality paints,
refloctrorised with Hi-Intensity retro – reflective sheeting
as per the latest and frame fabricated from suitable size
iron angle. The Sign Board is to be fixed on the base
prepared from channel and bracing angles which is
grouted by means of cement concreting of 1:2:4 for size
of 300 mm dia x 800 mm height (500 mm to be grouted in
ground). The details to be displayed on sign board will be
given by In-charge Engineer. (a) Hi intensity Micro
prismatic Grade
Providing and fixing of Sign Board (Danger Board) on
Distribution Transformer Centers
Made out of 2mm aluminium sheet size 300x300mm
(1x1ft) as per design, pre treated with phosphate process
and acid etching coated with one coat of epoxy primer
28 9925000028 and two coats of best quality paints, refloctrorised with No.
Hi-Intensity retro-reflective sheeting as per the latest and
frame fabricated from suitable size iron angle. The Sign
Board (Danger Board is to be fixed at the location as per
instruction of In-charge Engineer. (a) Hi intensity Micro
prismatic Grade
Providing & fixing of aluminium tag of size 250 mm (L) x
75 mm (W) from 3 mm aluminium sheet along with
mm dia aluminium binding wire for fixing of aluminium
tag near end termination joint at DP structure for
identifyng the cable. The details of feeder i.e. 11 / 22 KV
with feeder name shound be punched on the tag by letter
punch of size 16 mm as per instruction of Incharge
Supply & fixing of heat shrink type end terminations
30 9925000030 (outdoor) for 11kV 3C x 240 mm2 size XLPE cable as per No.
DGVCL technical specification
Supply & fixing of heat & shrinkable end terminations
31 9925000031 (outdoor) for 22 kV 3C x 240 mm2 size XLPE cable as per No.
DGVCL technical specification)
Supply & fixing of heat shrink type end terminations
32 9925000032 (indoor) for 11kV 3C x 240 mm2 size XLPE cable as per No.
DGVCL technical specification)
Supply & fixing of heat & shrinkable end terminations
33 9925000033 (indoor) for 22 kV 3C x 240 mm2 size XLPE cable as per No.
DGVCL technical specification
Supply & fixing of heat shrinkable straight through joint
34 9925000034 for 11kV 3C x 240 mm2 size XLPE cableas per DGVCL No.
technical specification.
Supply & fixing of heat shrinkable straight through joint
35 9925000035 type for 22kV 3C x 240 mm2 size XLPE cable as per DGVCL No.
technical specification
Installation, Testing and commissioning of 11 KV,630 A
SCADA Compatible, RRL type- 3 Way RMU including Two
36 9925000038 numbers of earthings as per Drawing (material is in No.
bidder's scope) and as per DGVCL Technical specification.
Installation, Testing and commissioning of 11 KV,630 A
SCADA Compatible, RRLL type- 4 Way RMU including
37 9925000039 Two numbers of earthings as per Drawing (material is in No.
bidder's scope) and as per DGVCL Technical specification.
Installation, Testing and commissioning of 22KV,630 A
SCADA Compatible, RRL type-3 Way, RMU including Two
38 9925000040 numbers of earthings as per Drawing (material is in No.
bidder's scope) and as per DGVCL Technical specification.
Installation, Testing and commissioning of 22KV,630 A
SCADA Compatible, RRLL type-4 Way, RMU including Two
39 9925000041 numbers of earthings as per Drawing (material is in No.
bidder's scope) and as per DGVCL Technical specification.
Construction of plinth for 11KV, RRL type- 3 Way (i.e
Two numbers of Isolator & One number of Breaker) Ring
40 9925000042 Main Unit as per DGVCL's technical specification No.
mentioned in drawing no: Drg. 11kv-01. All required
material will be supplied by contractor.
Construction of plinth for 11KV, RRLL type- 4 Way (i.e
Two numbers of Isolator & Two number of Breaker)Ring
41 9925000043 Main Unit as per DGVCL's technical specification No.
mentioned in drawing no:Drg. 11kv-02.All required
material will be supplied by contractor.
Construction of plinth for 22KV, RRL type- 3 Way (i.e
Two numbers of Isolator & One number of Breaker) Ring
42 9925000044 Main Unit as per DGVCL's technical specification No.
mentioned in drawing no: Drg. 22kv-01. All required
material will be supplied by contractor.
Construction of plinth for 22KV, RRLL type- 4 Way (i.e
Two numbers of Isolator & Two number of Breaker)Ring
43 9925000045 Main Unit as per DGVCL's technical specification No.
mentioned in drawing no:Drg. 22kv-02.All required
material will be supplied by contractor.
Modifications e.g.Providing and fixing of Terminal
protectors i.e. Re-use able boot (HT Side 11/22KV, LT Side
1.1KV) including 11/22 KV insulating taps and L.T.(1.1 KV)
insulating taps ,Busbar, Tapping from Bus Bar (11/22 KV
XLPE cable) through P.G. Clamp for H.T. Jumper to D.O.
Fuse to bushings of Transformer Center, providing &
Fixing of jumper and providing & fixing of Heat
Shrinkable Anti Tracking Core Insulating Tubing
(Insulation Level 11/22 KV) in H.T. jumper , Clamping
arrangement of cable support frame on both side of
existing Over Head type Distribution Transformer to
utilize in Under Ground cable network as per drawing &
as per instruction of Engineer incharge. All live parts i.e.
PG-Clamp, connections of D.O.fuses, HT bushings etc .
shall be covered with fixinng of 11/22 KV HT insulating
tapes. ( 11/22 KV XLPE cable will be in scope of DGVCL
while all other materials will be in bidder's scope ) .
Laying of any size of 11/ 22 KV XLPE /PILC Cable in Per Cable Per
redaymade trench or in open space Mtr
46 9925000060 Labour charges for Lying of O/H XLPE cable pole to pole KM
Supply of 150 mm dia (Inner), thickness 25 mm,
meter long RCC half round pipe
1.DGVCL will provide key material like M.S.
materials,ABC/Bare conductors,PSC/RSJ
Poles,Insulators,Fabricated materials etc. to the
contractor.2.All fabricated items shall be fabricated as per
DGVCL approved drawing and by welding rods confirming
to the relevent ISI specification and as directed by
Engineer in charge.3.Necessary electricity connection for
fabrication items shall be provided by DGVCL on payment
of required charge for connection & electricity bill of the
same shall be paid by the agency.4.All the rates are
Note: inclusive of PF & Exclusive of GST applicable time to
time.5.All steel material are to be painted as below:(a)
Scrubbing of rusted surface properly before applying the
paints on to the RSJ poles & steel fabricated materials of
RSJ/PSC poles is must required.(b) Two coats of approved
ISI mark red oxide (primer) is to be properly painted for
the RSJ poles & steel fabricated materials of RSJ/PSC
poles. (c) Two coats of approved ISI mark silver paint (i.e.
triple mangoes or equivalent quality silver paint) is to be
properly painted on to the RSJ poles & steel fabricated
materials of RSJ/PSC poles.
EXECUTIVE ENGINEERING
ANKLESHWAR IND DIVISION
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
RAW_HTML
1. Schedule A.pdf
14 Bid Document.pdf
14 Detail Technical Specification (1).pdf
SCHEDULE B.pdf
Download all tender documents and submit your bid