Loading…
Loading…
Tender Value
₹25.1 L
EMD Value
₹25,100
Closing Date
2 Jun 2026, 6:00 pmClosed
EXECUTIVE ENGINEER
Special repair to Streetlight and related items in RB and New Parade Ground, Baffle Range, Barrack (G+3), Gurudatt building and Main Road at SRPTC, Chowky, Dist:- Junagadh
304961
01 [2026-27]
Open
Civil - All
Works
Junagadh
9 documents required · 7 mandatory · 2 optional
₹1,500
GUJARAT STATE POLICE HOU.CORPORATION LTD.
₹25,100
13 May 2026
13 May 2026
13 May 2026
2 Jun 2026
13 May 2026
No. In Figure In Words
1 Providing & Erecting 2.0 mtr. long Earthing system by making 4.00 Each 7025.00 Rupees Seven
minimum bore of 225 mm dia. in soft soil. Suitable for doing pipe-in- Thousand
pipe technology earthing. Earthing electric rod must be made from Twenty Five Only
Corrosion free hot dip galvanizing pipes having following
specification.
(A) Earthing Electrode: outer Pipe: - 88 mm minimum O.D., 'B ' Class
ISI mark of Reputed Brand, Inner pipe: - 42 mm minimum O.D., Pipe
B Class ISI mark reputed Brand. Terminal Size: 70 mm X 100 mm
length, Terminal should be made from inner pipe for that pipe must
be pressed and gave rectangular shape so its work as a terminal.
The hot deep galvanising must be done after above process.
Galvanised thickness must be minimum 75 micron anywhere. SS Nut
bolt:- 2 nos. with washer suitable for 14 mm dia. hole must be
provided at terminal. Total minimum Weight (approx.) of earth
electrode with inside conductive material be 26 kg.
(B) Inner chemical (CCM Compound):- Resistivity:- 0.2 ohm/ meter
testing as per IEC 62561-2017, Voltage drop:- < 1 volt at no load &
dry form, Sulphur content:- <2%
(C) Back fill Compound:- Earthing compound should be capable to
retain moisture for long time. Back Filling Compound weight is 25 Kg.
(D) Chamber and cover:- Earthing chamber should be size of
mm X 400 mm X 400 mm depth and Cover should be heavy duty
cast iron with required size of 300 mm X 300 mm X 4 mm thick.
It. Estimate Quoted Rate in
Description of Item Qty Unit Amount
No. In Figure In Words
Necessary test report must be submitted.
1. Short circuit test by ERDA/ CPRI for 25KA
2. Resistivity test of conducting material from NABL accredited lab.
3. Hot dip galvanised / zinc coating micro test from reputed
laboratory.
4. General test report from OEM regarding specification of earthing.
[Make and model approved by EIC Strictly subject to item
specification only] [OEM has to submit all detail & sample for
approved before supplying]
[Water must be poured in bore before starting earthing. Earthing
value must be measured with earth tester. Agency has to bring the
earth resistance to at least 02 ohms & voltage between neutral &
Earthing upto 02 volt. Agency has to maintain earthing & its value for
one year. Earthing must be done in the presence of A.E. (GSPHCL)]
2 For Earthing Additional charges for boring in hard rock soil (by 4.00 Each 276.00 Rupees Two
Breaker)& filling soft soil in earth pit. (Certificate for soil have to given Hundred Seventy
by DEE/AE along with Photographs) Six Only
3 Providing & fixing double compressed heavy duty flange type brass 150.00 Each 43.00 Rupees Fourty
cable gland with rubber ring for P V C insulated armoured cable Three Only
complete with outgoing tails, insulating tape etc. For following size
cables.. For 2 to 4 core x 4.0 Sq. mm (Sigma, MCI, Comet Make
4 Supplying & erecting 12 mm thick Hylum sheet on existing 25 x 25 x 2.00 Sq. 2289.00 Rupees Two
3 mm red oxide painted angle iron frame suitable for fixing ICDP / Mtr. Thousand Two
ICTP / DPMCB / FPMCB SWITCH and energy meter (contractor Hundred Eighty
shall make approved drawing of Hylum sheet to arrange required No. Nine Only
of Energy meter & ICDP / ICTP / DPMCB / FPMCB switch-busbar
etc. as per Actual space available in electrical room at site)
It. Estimate Quoted Rate in
Description of Item Qty Unit Amount
No. In Figure In Words
5 Providing & Erecting Mains with ISI marked, 1.1 KV grade electrolyte 300.00 Mtr 141.00 Rupees One
multi stranded, annealed copper conductor with heat resistant PVC Hundred Fourty
insulated conforms to IS:694, IEC - 227 erected in existing pipe of One Only
following size (Specifically for control panel, relays, power
switchgears, motor starters & control wiring) with required size of
copper lugs, nuts and bolts if required. (Conductor resistance should
be as per IS:8130/1984) One wire 16.00 sq. mm
6 Providing and erecting bracket consisting of ISI mark "B" class G.I. 34.00 Each 487.00 Rupees Four
Pipe 4.2 cm outside diameter complete with suitable G.I. Sleeve Hundred Eighty
tubing of 2 mm. thick and required size and length suitable for 76.5 / Seven Only
80 mm. required size of pole top having nuts and bolts for fixing the
brackets and having spread of Upto 0.70 mtr. length with suitable
rise as per site condition and suitable welded stiffner reducer and
nipple with check nut complete painted with one coat of red oxide
and two coats of alluminium paint. or Single arm bracket suitable for
terrace as per design given by EIC (Jindal / Asian / Tata / Surya
Prakash make Only) (FabricatoRupees - Ambica / Fab / Bajaj /
Impression equipment Only) (Test certificate to be submitted) (a)
For Single arm bracket
7A Providing and erecting bracket consisting of ISI mark "B" class G.I. 25.00 Each 608.00 Rupees Six
Pipe 4.2 cm outside diameter complete with suitable G.I. Sleeve Hundred Eight
tubing of 2 mm. thick and required size and length suitable for 76.5 / Only
80 mm. required size of pole top having nuts and bolts for fixing the
brackets and having spread of 1.00 mtr. length with suitable rise as
per site condition and suitable welded stiffner reducer and nipple with
check nut complete painted with one coat of red oxide and two coats
of alluminium paint. or Single arm bracket suitable for terrace as per
design given by EIC (Jindal / Asian / Tata / Surya Prakash make
Only) (FabricatoRupees - Ambica / Fab / Bajaj / Impression
equipment Only) (Test certificate to be submitted) (a) For Single
arm bracket
It. Estimate Quoted Rate in
Description of Item Qty Unit Amount
No. In Figure In Words
7B For Double arm bracket 19.00 Each 821.00 Rupees Eight
Hundred Twenty
8 Supplying following size of Light duty “A” Class G.I . Pipe & erecting 130.00 Mtr. 171.00 Rupees One
as directed by Engineer-in-charge. (a) For 25 mm dia Hundred Seventy
9 Supplying & erecting approved make SMC press moulded 70.00 No 890.00 Rupees Eight
composite FRP loop-in, loop-out approx. 2mm thick box complete Hundred Ninety
with Bakelite connector strip 5way(3P+N+E),DIN rail for mounting Only
mob & hinged doors as per requirement having locking
arrangements with mounting clamp with nuts, bolts & washers
suitable for erection on pole with cable clamps& earth bolt of
following size of box. (A) 300 mm x 200 mm x 100 mm [deep]
10 Providing & making 1:2:4 cement concrete foundation & 70 % 5.00 Each 801.00 Rupees Eight
PCC from bottom including excavation for the pole of size 45 x 45 x Hundred One
100 cm. Deep in below ground level with plinth of 45 cm x 45 cm (or Only
45 cm dia x 45 cm) high upper ground level with necessary curing
and finishing in approved manner.
( for 4 & 6 mtr pole)
11 Breaking existing C.C. Foundation upto 0.5 mtr level and make the 23.00 Each 950.00 Rupees Nine
new C.C Foundation as per above item for the same. Hundred Fifty
12 Providing and making of Coil Type Earthing Having coil Made From 63.00 Each 369.00 Rupees Three
8 SWG Hot Deep Galvanized iron Wired wrapped On 50 MM OD Hundred Sixty
Round Pipe Having Minium 50 Turn( Approximately 200 mm lenght) Nine Only
& Having Contineous lenght Of 3 Mtr Gi wire To Connect Earthing
Bolt & Burried In Specially Prrepared Earth Pit Complete With Salt &
Charcoal/Coke As Required For Coil Type Earthing (Approximately
Weight Of Coil 1 To 1.1 KG)
It. Estimate Quoted Rate in
Description of Item Qty Unit Amount
No. In Figure In Words
13 Drilling the road without breaking the road surface (Asphalt) for 30.00 Mtr. 488.00 Rupees Four
laying of cable for feeding power supply by making up to following Hundred Eighty
size of holes at both ends complete. (A) Up to 100 mm bore dia. Eight Only
14 Providing, erecting, fabricating the M.S. structure as per requirement 150.00 Kg. 75.11 Rupees Seventy
of site as per structure design Including proper size approved by Five and Paisa
EIC of M.S. angles, flats, bars, square pipe, channels, sections Eleven Only
(Tata, Jindal, Asian, JSI Make) complete with cutting, welding,
grinding and finishing duly painted with Asian/Nerolac make premium
quality oil paint and true care red oxide metal primer,asian paint
make with erection on site as per direction of engineer in charge with
necessary grouting cementing, plastering and finishing complete. All
hole opening of square pipe end must be closed with M.S plate
welding. Payment will be done on KG as per Actual weight.
15 Providing & Erecting Flexible PVC insulated multistrand multicore 1.1 450.00 Mtr. 46.00 Rupees Fourty
kv grade ISI marked copper wires of following size to be erected as Six Only
directed. (a) 3 core 1.5 sq.mm. PVC insulated round copper wire
16 Providing & Erecting Flexible PVC insulated multistrand multicore 1.1 260.00 Mtr. 77.00 Rupees Seventy
kv grade ISI marked copper wires of following size to be erected as Seven Only
directed.(b) 3 core 2.5 sq.mm. PVC insulated round copper wire
17 Providing & erecting approved make XLPE (IS:7098) (I)-88 ISI mark 2900.00 Mtr. 361.00 Rupees Three
armoured multistrand Copper Cable 1100 volt to be laid 90 cms. Hundred Sixty
Under ground or to be laid on wall with 1.0 mm thick G.I. heavy One Only
guage cable clamp or in existing DWC pipe underground or road
crossing or floor of following size of cables.(d) For 4 core x 4.0 mm2
It. Estimate Quoted Rate in
Description of Item Qty Unit Amount
No. In Figure In Words
18 Providing & fixing Solderless crimping type Copper lugs conforming 1200.00 Each 8.00 Rupees Eight
to IS suitable for cable of following size evenly crimped with high Only
pressure tool & connected to switchgear terminals with
brass/cadmium plated nut bolts in an approved manner. (A)
19 Providing & laying HDPE Double walled corrugated pipes (DWC) 1850.00 Mtr. 117.00 Rupees One
(conforming to IS: 16205 (part 24) 2018)) with minimum load required Hundred
of 450N capacity with anti rodent and ultra violet material properties Seventeen Only
with necessary connecting accessories of same material at required
depth to be laid 90 cms. under ground for laying of cable below
ground / road surface for enclosing cable and back filling the same to
make ground as per original. (A)For Outer dia.50 mm and Inner
dia. 38mm (Test Certificate to be Submitted)
20 Supplying and erecting Galvanized iron pipe post ISI mark 'B' 11.00 Each 4397.00 Rupees Four
class 88.9 mm. O.D. 6 mtrs. Long duly painted with two coats of Thousand Three
alluminium paint and metallic base plate of 300 x 300 x 4 mm. thick Hundred Ninety
to be erected as a compound light pole with wire entry nipple and Seven Only
earthing bolt. Approximate weight of pole 47 Kg. within permissible
limits as per IS effective length of sections Bottom: 5.5 mtr. having
outside dia. 88.9 mm. Top: 0.5 mtrs. having outside dia. 76.1 mm. (
ISI test certificate from pipe manufacture &
Class/make/length/O.D/wall thickness/GI/ MS/ Weight test certificate
from pole manufacture shall be submitted) (Jindal / Asian / Tata /
Surya Prakash make only For G.I Pipe) (Manufacturer's make
Ambica,Fab,Bajaj only,Test Certificate to be Submitted)
It. Estimate Quoted Rate in
Description of Item Qty Unit Amount
No. In Figure In Words
21 Supplying and erecting approved make Octagonal pole made from 20.00 Each 11410.00 Rupees Eleven
HR sheet steel. The pole should be made as per IS. and shall be Thousand Four
coated with hot dip galvanizing as per IS 2629/2633/4759, suitable Hundred Ten
suspend local wind speed with integral Junction box with Hot Deep Only
Galvanised door having 2 nos. 180° operated hinges & 2 nos. Ln key
locking with silicon rubber gasket. Consist of terminal plate of min
6mm Hylam sheet, standard profile 35mmX7.5mm Din-Rail & MCB
Brass stud type terminal and arrangement for cable termination to
be erected on RCC foundation as per details given by manufacturer
and EIC considering site requirement.
Foundation Details: 1) Grade of RCC 1:2:4, 2) Grade of steel
rainforcement of RCC FE 415, 3) Clear cover to rainforcement
50mm, 4)Concrete vibrated, 5) use suttering / farma, 6)Hot deep
galvanized average 70Micron, 7) Detail drawing will be given by
corporation. (Make:- Bajaj, Valmont, Ambica, Transril)
(E) 7 Mtr. Long 70 mm Top X 135 mm bottom dia, 3 mm thickness
with 225mmX225mmX16mm base plate, 4-M20 Bolts and 600mm
long hot deep galvanized J-Bolt, nuts, washers with 1300mm under
ground and 200mm above ground level and 450mm dia. Foundation
in 1:2:4 proportion.
22 Painting of Streetlight pole with bracket complete with primer with 41.00 Each 263.00 Rupees Two
two coats of Aluminium paint for following size of pole.Up to 6 Mtr. Hundred Sixty
Three Only
23 Providing & erecting 240 V MCB double pole switch for motor & 5.00 Each 327.00 Rupees Three
inductive load (C Curve) having 10 KA breaking capacity & Hundred Twenty
confirms to IS : 8828 in existing box having following capacity (B)For Seven Only
40 Amp. DP
It. Estimate Quoted Rate in
Description of Item Qty Unit Amount
No. In Figure In Words
24 Providing and erecting Medium Class FIA approved and ISI mark 250.00 Mtr. 33.00 Rupees Thirty
white colour (embossed) RIGID PVC PIPES of following size Three Only
complete erected with necessary PVC fittings & Junction boxes fixed
with adhesive solution & clamps on / in wall / ceiling along with
continuous fish wire to draw mains with necessary fittings and
junction boxes for following dia. For 25 mm dia.
25 Providing, erecting, testing and commissioning insu intelligent street 3.00 Each 20255.00 Rupees Twenty
light controller specially designed for energy saving in conventional Thousand Two
street light system ( Cat. no. SLC-03-1Ph-15 KVA-20 Amp. per Hundred Fifty
phase) having technical specification, 1 phase 2 wire, 230 V AC/ph, Five Only
+/- 25% R Y B N 2 wire supply system, 50 Hz (+/- 10%) 2 W (Stand
BY) to 4 W (at street light operation) consumption, Advance 8 bit
micro controller, switching on longitude and latitude base, accuracy
of +/- 1 minute per month, with in built battery, with battery life of
more than 8 years, with special device which hold the parameter for
more than 10 year without any power and password protected.
16 characters and two line LCD display with backlight, 4 keys user
friendly keyboard system, 7500/15000 VA feeder pillar capacity,
60/100 Amps isolator, 3 output with termination, 40/63 Amps 2/3 pole
contactor, 3 X 16 Amp., with FR cable provision to by pass by way of
relay operation through auto/manual switch, 2 to 55 centigrade and
humidity 90 % non condensing, Out door type installation on pole
with clamps (Provided with clamps and nut bolt) or wall or floor,
Three locking system flush type internal panel lock, external pad lock
and internal U clamp locking systems for against theft of Panel,
having 17/25 Kg weight, 18 Gauge MS weather proof box with
industrial exterior powder coated with 7 tank process RAL
It. Estimate Quoted Rate in
Description of Item Qty Unit Amount
No. In Figure In Words
26 Providing & Erecting Univesal Astro interlligent Street light 2.00 Each 12895.00 Rupees Twelve
Control Syatem insu with weather proof box for indoor allplication Thousand Eight
5KVA ( as Per atteched Specification) Hundred Ninety
27 SITC of Outdoor aesthetically designed LED Street Light Luminaire 73.00 Each 3512.00 Rupees Three
with total consumption of Max. 45 W with single piece die cast Thousand Five
aluminium housing, high power LED shall be mounted on high quality Hundred Twelve
metal core PCB with extremely precison designed heat sink Only
complete with IP66 protection Class with polycarbonate / thoughened
glass cover the fixture should be suitable for pole/bracket mounting.
The fixture to comply both LM79 and LM 80 guidelines with LED
module min. 130 lumen/watt with toughen Glass L70 at 50,000 hrs,
provided with high quality polycarbonate lenses for better light
distribution. The Fixture Should be able to be Pole Mounted and also
bracket mounted, provided with high quality driver for protection
against high and low Voltage cut Off, opertional for high amibient and
high humid envirnoments, THD of driver should be less than 10%
and P.F > 0.95. Also the Fixture should meet the following technical
criterias Oprating range Voltage 160 to 270 V, system efficiency >=
110 lm/w, and total lumens not less then 4950, CCT > 5000K, CRI >
65, beam angle 120 deg, 4kV integral & non integral surge immunity
level at least 10 KV non integral..The Separate Potted driver should
have over current, over voltage protection, short circuit protection so
that the fixture recovers once the fault is removed. In addition to the
above product should be operational in the temperature range of
deg to 50 deg and humidity range of 10% to 90% RH. (Note:- The
manufacturer / authorized Channel partner of the manufacturer has
to submit 5yrs free replcement Guarantee for complete Fixture)
It. Estimate Quoted Rate in
Description of Item Qty Unit Amount
No. In Figure In Words
28 SITC of Outdoor aesthetically designed LED Street Light Luminaire 13.00 Each 6701.00 Rupees Six
with total consumption of Max. 120 W with single piece die cast Thousand Seven
aluminium housing, high power LED shall be mounted on high quality Hundred One
metal core PCB with extremely precison designed heat sink Only
complete with IP66 protection Class with polycarbonate / thoughened
glass cover the fixture should be suitable for pole/bracket mounting.
The fixture to comply both LM79 and LM 80 guidelines with LED
module min. 130 lumen/watt with toughen Glass L70 at 50,000 hrs,
provided with high quality polycarbonate lenses for better light
distribution. The Fixture Should be able to be Pole Mounted and also
bracket mounted, provided with high quality driver for protection
against high and low Voltage cut Off, opertional for high amibient and
high humid envirnoments, THD of driver should be less than 10%
and P.F > 0.95. Also the Fixture should meet the following technical
criterias Oprating range Voltage 160 to 270 V, system efficiency >=
110 lm/w, and total lumens not less then 13200, CCT > 5000K, CRI
> 65, beam angle 120 deg, 4kV integral & non integral surge
immunity level at least 10 KV non integral..The Separate Potted
driver should have over current, over voltage protection, short circuit
protection so that the fixture recovers once the fault is removed. In
addition to the above product should be operational in the
temperature range of 0 deg to 50 deg and humidity range of 10% to
90% RH. (Note:- The manufacturer / authorized Channel partner of
the manufacturer has to submit 5yrs free replcement Guarantee for
complete Fixture)
It. Estimate Quoted Rate in
Description of Item Qty Unit Amount
No. In Figure In Words
29 SITC of Outdoor aesthetically designed LED Flood Light Luminaire 21.00 Each 6228.00 Rupees Six
with total consumption of maximum 90 W with single piece die cast Thousand Two
aluminium housing, LED's mounted on high quality metal core based Hundred Twenty
PCB with extremely precison designed heat sink, complete with IP66 Eight Only
protection Class, with polycarbonate / Toughened glass cover. The
fixture should be suitable for pole/bracket mounting. The fixture to
comply both LM79 and LM 80 guidelines with LED minimum
lumen/watt with L70 at 50,000 hrs, provided with high quality
polycarbonate Seperate lenses for better light distribution. The
Fixture Should be able to be Pole Mounted and also bracket
mounted, provided with high quality potted driver for protection
against, high and low Voltage cut Off, opertional for high amibient
and high humid envirnoments, THD of driver should be less than
10% and P.F > 0.95. Also the Fixture should meet the following
technical criterias. Operating range Voltage 160 to 270V, system
efficiency > 110 lm/w, CCT > 5000K, CRI >65, beam angle 120 deg,
4kV integral & non integral surge immunity level at least 10 KV non
integral... Flood Light lumens shall be more than 9900 (Note:- The
manufacturer / authorized Channel partner of the manufacturer has
to submit 5yrs free replcement Guarantee for complete Fixture)
It. Estimate Quoted Rate in
Description of Item Qty Unit Amount
No. In Figure In Words
30 SITC of Outdoor aesthetically designed LED Flood Light Luminaire 6.00 Each 7395.00 Rupees Seven
with total consumption of maximum 120 W with single piece die cast Thousand Three
aluminium housing, LED's mounted on high quality metal core based Hundred Ninety
PCB with extremely precison designed heat sink, complete with IP66 Five Only
protection Class, with polycarbonate / Toughened glass cover. The
fixture should be suitable for pole/bracket mounting. The fixture to
comply both LM79 and LM 80 guidelines with LED minimum
lumen/watt with L70 at 50,000 hrs, provided with high quality
polycarbonate Seperate lenses for better light distribution. The
Fixture Should be able to be Pole Mounted and also bracket
mounted, provided with high quality potted driver for protection
against, high and low Voltage cut Off, opertional for high amibient
and high humid envirnoments, THD of driver should be less than
10% and P.F > 0.95. Also the Fixture should meet the following
technical criterias. Operating range Voltage 160 to 270V, system
efficiency > 110 lm/w, CCT > 5000K, CRI >65, beam angle 120 deg,
4kV integral & non integral surge immunity level at least 10 KV non
integral... Flood Light lumens shall be more than 13200 (Note:- The
manufacturer / authorized Channel partner of the manufacturer has
to submit 5 yrs free replcement Guarantee for complete Fixture)
31 Supplying & fixing box for housing ELCB + MCB combination made 5.00 Each 272.00 Rupees Two
of 18 SWG sheet steel duly powder coated with gasket, dust & Hundred Seventy
vermin proof bakelite shield two earthing terminals for following type Two Only
of RCCB, ELCB, ELCB + MCB (a) For 2 pole
Total in Rs.
Contractor Signature Ex.Engg,(Ele.)(SP)
G.S.P.H.C.Ltd,
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
RAW_HTML
1 SBD Book Choki Street Light.pdf
2 SCH B Choki Street Light New.pdf
3 Electrical Booklet 2024.pdf
New Jaher Nivida 2025-26 (01).pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .