Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹16.9 LAccepted-AOC | L1 | Accepted-AOC AOC | |
| 2 | L2₹19.1 L+₹1.3 L (7.32%)Rejected-Finance | L2 | Rejected-Finance Other than lowest | |
| 3 | L3₹19.4 L+₹1.6 L (8.86%)Rejected-Finance | L3 | Rejected-Finance Other than lowest | |
| 4 | L4₹19.7 L+₹1.8 L (10.3%)Rejected-Finance | L4 | Rejected-Finance Other than lowest |
Tender Value
₹16.2 L
EMD Value
₹32,400
Closing Date
6 Jun 2020, 6:00 pmClosed
GE Kargil
GE Kargil, ladakh
PROVN OF TOILET AND BATHROOM FOR H COY OF INF BN TA AND SPECIAL REPAIR TO INTERNAL WIRING AT OFFICER MESS OF HQ 56 MTN BDE AT DRASS
2020_MES_316522_5
GE/K-61/2019-20
Open Tender
Civil Works
Item Rate
180 days
Drass Kargil
Please refer Tender documents.
7 documents required · 7 mandatory
₹500
Yes
GE Kargil
₹32,400
Yes
3 Oct 2020
21 May 2020
8 Jun 2020
21 May 2020
6 Jun 2020
25 May 2020
Amount
Excavation in trenches, not exceeding 1.5mtr wide and not exceeding 1.5 mtr depth, for foundation, etc, or for shafts, wells, cesspits, manhole, pier holes etc not exceeding 10 Sq m on plan and not exceeding 1.5 m in depth and getting out in hard/dense soil, complete all as specified and directed by Engineer-in-charge.
Excavating over areas, n exc 1.5 m deep and getting out in hard / dense soil
Excavating over areas, exc 1.5 m deep but n exc 3 m in deep and getting out in hard / dense soil
M&L for Plain cement concrete 1:4:8 type D-2, (using 40mm graded crushed stone aggregate) as in foundation, filling and mass concrete, complete all as specified and directed by Engineer-in-charge.
M&L for stone masonry walling of random rubble, uncoursed, well bonded, bedded and solidly hearted, bulit in cement mortar 1:6, complete all as specified and directed by Engr-in-Charge.
M&L for stone masonry walling of random rubble, uncoursed, well bonded laid dry complete all as specified and directed by Engr-in-Charge.
M&L for Precast cememt concrete type-C-1 block masonary with solid blocks 1:3:6 (using 20mm graded crushed stone aggregate) exc. 10cm in width and setting in cement mortar (1:6), complete all as specified and directed by Engr-in-Charge.
M&L for Precast cement concrete block masonry type C-1, 1:3:6 (using 20mm graded crushed stone aggregate) with solid blocks not exceeding 10cm in width and setting cement mortar 1:4 , complete all as specified and directed by Engr-in-Charge.
M & L for rendering 15 mm thick on vertical surfaces in CM 1:4, finished even and fair, complete all as specified and directed by Engr-in-Charge.
Preparation of newly plastered surfaces of walls and applying two coats of cement based paint over a coat of alkali resistant priming coat , complete all as specified and directed by Engr-in-Charge.
Returning, filling in soft/loose soil, including spreading, levelling, watering and well ramming in layers not exceeding 25cm thick, complete all as specified and directed by Engineer-in-charge.
Removal surplus soil not exceeding 50mtr and depositing where directed at level not exceeding 1.5mtr above the starting point, complete all as specified and directed by Engineer-in-charge.
Earth filling under floor including spreading, levelling, well ramming, watering in layers n.exc 25 cm thick complete all as directed (earth to be arranged by contractor at his own cost)
M&L for Hardcore of brken stone or boulder gauge n.exc 63 mm, deposited , spread and levelled in layers n.exc 15 cm thick , watered and rammed to a true surface, complete all as specified and directed by Engr-in-Charge.
M & L for 75mm thick, plain cement concrete, type D-2, 1:4:8, (using 40mm graded stone aggregate) as in sub base flooring, surface finished even and rough to receive floor topping, complete all as specified and directed by Engr-in-Charge.
M&L for reinforcement cement concrete (nominal mix) type A1 (1:1.5:3) (using 20mm graded crushed stone aggregate) in foundation , including rafts, footing,foundation beams, plinth beams, bases for coloums etc.complete all as specified and directed by Engr-in-Charge.
Providing plain cement concrete B-1 (1:2:4) using 20 mm graded crushed stone aggregate as in coping, bed plates, seismic bands, lintels upto 1.5 m clear span, plinth courses and other similar bands the like finished fair & even, including necessary form work, complete all as specified and directed by Engr-in-Charge.
M&L for reinforcement cement concrete (nominal mix) type A1, (1:1.5:3) (using 20mm graded crushed stone aggregate) as in columns, pillars, piers, posts and struts, complete all as specified and directed by Engr-in-Charge.
Providing precast cement concrete Type B-1 1:2:4 (20 mm graded aggregate) in landings, cover slabs (for man holes etc.) chullah hoods, chajjas, water oughs, mangers, shelves and similar articles with plain frames set in CM1:6 , all as specified and directed.
M&L for Providing reinforced cement concrete 1:1.5:3 type A-1 (using 20 mm graded crushed stone aggregate) as in slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slab and in shelves and the like, complete all as specified and directed by Engineer-in-charge.
Form work to sides of pillers posts struts piers coloums and stanchions etc.complete all as specified and directed by Engr-in-Charge.
Form work to sides of conrete foundation footings bases of columns, raft and raft beams sides and soffits of foundation and plinth beams and similar work etc. complete all as specified and directed by Engr-in-Charge.
Use & waste form work to soffits of suspended slabs, such as roof slabs, landings and similar work not exceeding 200 mm thick with rough finished flat surfaces of concrete, complete all as specified and directed by Engineer-in-charge.
S & F for Rolled mild steel in joist, channel, angle, or tee sections, fixed independently with connecting plates etc onfirming to Fe 410-W (Gde-E-250) quality A, complete all as specified and directed by Engr-in-Charge.
Rolled mild steel in roof trusses (framed) purlins, crane gantries, rails and fastenings and heavy brackets freming (beams, tee, angle channel or flat sections) including distance pieces, cleats etc confirming to Fe 410-W (Gde-E-250) quality A, complete all as specified and directed by Engr-in-Charge.
S&F Second class soft wood (KAIL), plain, solid, straight chowkats and frames, wrought, framed rebated on the solid, rounded or chamfered, put together with glue pinned at joints, complete all as specified and directed by Engr-in-Charge.
Second class soft wood (KAIL) plain, framed, panelled shutters (any number of panels), 35 mm thick with panels of 9mm ply BWP commercial type or 12 mm thich of veneered particle board with commercial veneering both faces as in doors, complete all as specified and directed by Engr-in-Charge.
Supply and fixing 100 mm long mild steel butt hinges medium weight cold rolled , complete all as specified and directed by Engr-in-Charge.
Supply and fixing 75 mm long mild steel butt hinges medium weight cold rolled , complete all as specified and directed by Engr-in-Charge.
S & F 100 mm long Aluminium anodised, barrel tower bolts of extruded section, complete all as specified and directed by Engr-in-Charge.
S & F 150 mm long Aluminium anodised, barrel tower bolts of extruded section, complete all as specified and directed by Engr-in-Charge.
S&F 100mm long, mild steel handles cast type , fitted, complete all as specified and directed by Engr-in-Charge.
S&F 150mm long, mild steel handles cast type , fitted, complete all as specified and directed by Engr-in-Charge.
S&F Mild steel sliding door bolt 250 mm long plate type slove enamelled blak wioth bright bolt not less than 12 mm dia with and incl a minimum of 6 bolt and nut four on bolt plate and two on staple plate and fixed, complete all as specified and directed by Engr-in-Charge.
S & F 3mm thick sheet glass ordinary quality and glazing with oil putty in square not exceeding 0.50 Sqm in each pane, complete all as specified and directed by Engr-in-Charge.
S&F 30 mm thick 2nd class soft wood skeleton shutters, divided into quare with plain chamfered or rounded mitrerd and rebated sash bars for windows any numbers, size of stiles and rail as specified in SSR (2009) Part-I section 8 clause 8.24 (b), complete all as specified and directed by Engr-in-Charge.
Prepation of new wood based surfaces of any description over 10 cm width or girth and applying two coats of synthetic enamel Paint over a coat of pink primer, complete all as specified and directed by Engr-in-Charge.
M&L for 75mm thick PCC 1:3:6 type C-2 (using 40mm graded crushed stone aggregate) as in plinth protection, complete all as specified and directed by Engr-in-Charge.
M&L mild steel TMT bars 10 mm dia and over cut to length bent to shape required inclduing cranking bending spirally for hooping ends and binding with and incl mild steel wire (annelaed) not less than 0.90 mm dia or securing with clips.
All as per Srl item No 1.39 here in before but 6mm to 8 mm as in stirrups/specers
M&L for Rendering 10 mm thick in cement mortar 1:6 on fair faces of brick masonry, finished the surface even and smooth without using extra cement, complete all as specified and directed by Engineer-in-charge.
M&L preparation of new plastered surfces of walls and applying two coat of OBD over a coat of birla wall care putty for smoothness of surfaces.
S & F non skid ceramic tiles coloured , 7 to 8mm thick (Square/rectangular) area of each tile exceeding 0.06Sqm but not exceeding 0.11 sqm, in floor etc, set and jointed in neat cement sturry and pointed in white cement with pigment to match all as specified.
M&L 15mm thick screed bed or bedding layer in cement mortar 1:6 , for laying floor finishes, complete all as specified and directed by Engr-in-Charge.
M&L for Rendering 10 mm thick on fair faces of brick work or concrete surfaces in CM 1:4, finished even and fair for backing coat plaster for skirting and dado complete all as specified and directed by Engr-in-Charge.
M & L for Glazed ceramic coloured tiles of size 300x200x7 mm thick on vertical surface such as in dado/skirting/risers to steps etc set and jointed in neat cement slurry and pointed in white cement with pigment to match the shade of tiles, complete all as specified and directed by Engr-in-Charge.
S & F in repairs vitreous china water closet (squatt pan) orrisa pattern 630x450 mm size pan white with front or back inlet with intergral foot rests including provn of lime concrete bedding including connections to flushing cistern/pipe, complete all as specified and directed by Engr-in-Charge.
Supply and fixing in repair PVC low level flushing cistern 10 Ltr capacity with & including brackets for fixing to walls and PVC flush pipe of LDPE pipe of pressure rating 6 kgf/ sq.cm, complete all as specified and directed by Engr-in-Charge.
S&F for Vitreous China bowl urinal flat back, size of 465x355x265mm, including fixing plugs bedding urinal against wall in cement mortar 1:2 securing urinal to plug with and incl 60 mm long brass screws, pointing aournd urinal and provision of waste pipe PVC suitable for urinal pot, complete all as specified and directed by Engr-in-Charge.
Pillar taps 15 mm bore, fancy type cast copper alloy, with capstan heads, chromium plated, screwed down high pressure, with or without lettered 'Hot' or 'Cold' with long screwed shanks and fly-nuts, screwed for iron pipe, complete all as specified and directed by Engr-in-Charge.
Supply and fixed in repairs Vitreous china wash basin(counter sunk type), flat back, size 550X400 mm including waste pipe, bracket and cutting for and pinning in ends of brackets or errecting stand but excluding taps, chain and plug, complete all as specified and directed by Engr-in-Charge.
S&F waste coupling of PTMT (half or full threaded) 32 mm dia 45 gms of discharge pipe, complete all as specified and directed by Engr-in-Charge.
S&F PVC (SWR) floor trap, plain with grating including joinery with solvent cement diameter of outlet 75 mm, complete all as specified and directed by Engr-in-Charge.
S&F 75 mm bore PVC (SWR) pipe single socketed any length with rubber rings joints laid in floors floor trap, plain with grating including jointing with solvent cement, complete all as specified and directed by Engr-in-Charge.
S&F 110mm bore pipe PVC (SWR) pipes single socketed, in any length with rubber ring joints, laid in trenches or in floor , complete all as specified and directed by Engineer-in-charge.
S&F PVC pipe waste pipe 32mm dia and 75cm long incl waste coupling fixed to waste coupling.
Supply and fixing Bib taps,15 mm bore,fancy type, cast copper alloy with crutch or butterfly handle, screwed down, screwed for brass ferrule, complete all as specified and directed by Engr-in-Charge.
Supply and fixing in repair 15mm dia GI tube medium grade galvanised, with all fitting and fixed to walls and ceilings or laid in floors, complete all as specified and directed by Engr-in-Charge.
Supply and fixing in repair 20mm dia GI tube medium grade galvanised, with all fitting and fixed complete laid in trenches, complete all as specified and directed by Engr-in-Charge.
PVC connections 15 mm size with PTMT nuts of length 450 mm, complete all as specified and directed by Engr-in-Charge.
Supply and fixing 1000 Ltr capacity Rotational moulded HDPE water storage tanks (Cylindrical vertical closed top), double wall construction, hoisted and fixed in position or placed in position inside or outside the building, connecting up pipes and securing access covers, complete all as specified and directed by Engr-in-Charge.
Supply and fixing 20mm dia Gun metal globe or gate valve iron wheel head, screwed both ends, heavy duty ISI marked, complete all as specified and directed by Engr-in-Charge.
S&F Pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50 mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to walls,fixed with self tapping screw, complete all as specified and directed by Engr-in-Charge.
S&F Pre-painted galvalume aluminium zinc coating GI based plain steel sheet 0.50 mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to walls,fixed with self tapping screw, complete all as specified and directed by Engr-in-Charge.
Preparation of new steel surfaces of any description, over 10 cm in width or girth, not otherwise described and applying two coats of synthetic enamel paint, over a coat of red oxide complete all as specified and directed by Engr-in-Charge.
Towel rail, 600mm long of PTMT fixed with and including chromium pated brass srews and wooden/plastic cleats, complete all as specified and directed by Engr-in-Charge.
M&L for cement 1:2:4 type B-2 (Using 40 mm graded crushed stone aggregate) as in surface channels and drains, complete all as specified and directed by Engr-in-Charge.
M&L for forming fair finishes drain or channel 30 cm inner girth in cement concrete using extra cement all as specified and directed.
S & F LLDPE septic tank dsigned to carry sewage and sullage water including excavation in hard/dence soil, PCC 1:4:8 below tank, vent shaft, connection etc, complete for 30 users with upflow filter including media all as per manufacture instruction complete all as specified and directed.
Taking down carefully copper or aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches ceiling roses, pendants, sockets bulk, head fitting, tube light fitting by unscrewing carefully from boards etc and making good, distrubed surface of walls floors etc. , complete all as specified and directed by Engr-in-Charge..
Point wiring with multi-stranded copper conductor PVC insulated and unsheathed cable in PVC casing and capping, 1.5 Sqmm with all fittings/accessories and including 1.5 Sqmm PVC insulated copper earth wire connected to common earth including closed recessed wooden terminal Boxes of suitable size made of 2nd class hard wood for mounting switches, sockets etc with 3mm thick laminated sheet cover for one light point or bell/buzzer point controlled by one switch, complete all as specified and directed by Engr-in-Charge..
All as per Srl item No 1.72 here in before but for one 3 pin socket outlet 5 Amps on independent board.
All as per Srl item No 1.72 here in before but for one 3 pin 5 Amps switch socket on same board.
All as per item no. 1.72 here-in-before but using 2.5 sqmm for one three pin socket outlet 15 Amps switch socket outlet on independent board, complete all as specified and directed by Engr-in-Charge.
S&F switch flush type 15 amps single pole one way complete all as specified and directed.
S&F socket outlet 2 in 1, 5 and 15 amps flush type one way complete all as specified and directed.
S&F socket outlet flush type 3/5 pin 5/6 Amps 230 volt AC complete all as specified and directed.
S&F Switch piano 5 Amps, single pole one way flush type, complete all as specified and directed by Engr-in-Charge..
S&F Switch socket combination 2 in 1, 5 and 15 Amps, Flush type, complete all as specified and directed by Engr-in-Charge.
S&F Ceiling rose surface bakelite 65x50mm, two to three terminals, complete all as specified and directed by Engr-in-Charge.
S&F Lamp holder, insulated body with back plate suitable for batten fittings, complete all as specified and directed by Engr-in-Charge.
Sheet metal enclosure for DB's double door, single pole and neutral, 240V, 8 way with 200 Amp rated bus bar including blanking plates where required, complete all as specified and directed by Engr-in-Charge.
S&F MCB, single pole and neutral, 32 Amp, 240V, 10KA, complete all as specified and directed by Engr-in-Charge.
S&F MCB, single pole, 5 to 32 Amp, 240V, 10KA, complete all as specified and directed by Engr-in-Charge.
Rectangular block of second class hard wood of size 30 x 25 x 5 cm depth, closed recessed, complete all as specified and directed by Engr-in-Charge.
Earthing complete with galvanised steel earth plate electrode 600mm x 600mm and 6 mm thick buried directly in ground not less than 2.25 mtr deep below normal ground level with top edge of plate not less than 1.5 metres below normal ground level, connected to the Galvanized iron earth wire 4.0mm dia by means of bolts, nuts, check nuts and washers of galvanized iron protected by provision of G I light grade pipe 40mm bore including provision of concrete pit in PCC 1:2:4 type B1 using 20mm grade stone aggregate with 40mm thick cover of RCC 1:2:4 reinforced with XPM (weight not less than 4Kg/Sqm) and frame of angle iron 25x25x6mm with lugs two number and with 6mm dia MS bar handle made to shape and GI medium grade 20mm bore pipe for watering perforated at bottom 1.75m long placed on top edge of earth plate, common salt and charcoal filling, test point made out of 40mmx8mm flat iron with fixing arrangement funnel wire mesh and earth work in hard/dense soil, returing filling in and removal of surplus soil to a distance not exceeding 50M all as per electric plate No 3 of SSR Part-I conected to earth test point as specified or indicated including testing on completion.
House Service bracket (hook type) complete with 3.0 m long G.I pipe 40 mm dia (medium grade), two numbers 90° bends, M.S hook and stay including taking down the existing unserviceable bracket. NOTE :- The unit rate shall to include for :- (a) Cutting holes in walls etc. of any description, grouting rag bolts and making good with cement mortar 1:3 including making good finishing to match the existing work and removing rubbish off the premises as directed (in case of bracket being fixed to masonry wall). (b) G.I pipe house service bracket hook type fabricated out of 3.0m long screwed G.I pipe of medium grade and comprising of two number 90° bend (pipe dia) screwed tight to the top ends of the service vertical limb, the two ends of the service provided with two number of turned spit tight fit, well seasoned teak wood bushing and the bracket fixed plumb vertical against the wall with two number flat iron clamps (fabricated out of 50 x 6mm flat iron with 4 No. 16 mm dia ragged bolts of appropriate size with screwed ends, tightened with 16 mm dia nuts with 6 mm thick washer against the clamp tightening collar.
Supply and fixing LED 18 Watt Tubelight fitting decorative ultra slim square profile linear with extruded polycarbonate environment friendly Make Havells Cat part LHEXBTP7IN1W018, complete all as specified and directed by Engr-in-Charge.
S&F LED bulb 20 watt 230 volt, 50 Hz complete.
M&L for exhaust fan complete with metallic blade , heavy duty , mortor 240 V single phase of size 300 mm sweep incl making hole etc and fixation with 04 nos fully threaded bolt grouted in wall , nut and proding , wire mesh from out side complete with connection, complete all as specified. and directed by Engr-in-Charge
Sub main wiring with two single core 6 sqmm multistranded copper conductor cable, PVC insulated cable 1100 volts grade and 4 Sqmm as continous earthing drawing and including PVC casing and caping of suitable size with all acessories, complete all as specified and directed by Engr-in-Charge.
All as per item no. 1.92 here-in-before but cable size 2x4 sqmm for phase & neutral and 1x4 sqmm for earthinh -ditto-
1100 volts grade heavy duty 10 sqmm 2 core flat cable PVC insulated aluminium stranded conductor, served with inner sheathing of PVC tape and overall PVC sheathed in service connections suspended by insulating hangers not more than 01 metre apart including 4 mm suspension , complete all as specified and directed by Engr-in-Charge.
Amount of Sch 'A' Part - II (Credit Schedule) Rs. 7948.00 (minus) as listed in Schedule of credit shall be deducted from total BOQ during AOC.
M/S O PAL ENGINEERS & CONSTRUCTION COMPANY
M/S Kharzongla Enterprises
CHAMRAN TRADING NAD CONSTRUCTION KARGIL
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .