Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
EEEANDMWSCN
DELHI JAL BOARD OFFICE OF THE EXECUTIVE ENGINEER E AND M WS CN NEAR KANHIYA NAGAR METRO STATION DELHI 35
Renovation/Electrification of Room No. 101 being used by Member (A) at varunalaya Ph-II and Room No. 401, 408, 415 , D/Man cabin at Varunalaya Ph-I and other allied works.
2021_DJB_205681_9
NIT NO. 04 (2021-2022)
Open Tender
Miscellaneous Services
Item Wise
30 days
EEEANDMWSCN
Please refer Tender documents.
3 documents required · 3 mandatory
₹500
THROUGH DJB OFFICIAL WEBSITE IN LINK TENDER
₹14,500
Yes
1 Sept 2021
13 Jul 2021
19 Jul 2021
13 Jul 2021
19 Jul 2021
13 Jul 2021
120 days
Wiring of light point /fan point/ exhaust fan point /call bell point with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable in surface/recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq. mm. FRLS PVC insulated copper conductor single core cable etc. as required. (DSR No. 1.10.3 Group C)
Supply and fixing suitable size GI box with modular plate and cover in front on surface or in recess , including providing and fixing 6 in 5/6 & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required. (DSR No. 1.32)
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 A modular socket outlet and 5/6 A modular switch, connections etc. as required. ((DSR No. 1.31)
Supply and fixing two module stepped type eletronic fan regulator on the existing modular plate switch box including connecctions but excluding modular plate etc. ass required. (DSR No. 1.25)
Wiring for circuit/submain wiring along with earth wire with the following size of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required.2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire. ( DSR No. 1.14.1)
Wiring for circuit/submain wiring along with earth wire with the following size of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required.2x2.5 sq. mm +1x2.5 sq. mm earth wire. ( DSR No. 1.14.2)
Wiring for circuit/submain wiring along with earth wire with the following size of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required.2x4 sq. mm +1x4 sq. mm earth wire .(DSR No.1.14.3)
Wiring for circuit/submain wiring along with earth wire with the following size of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required.4x10 sq. mm +2x6 sq. mm earth wire. (DSR No. 1.14.10)
Supplying and fixing of 4 way (4 + 12), Double door, surface/ recess mounting, vertical type, 415 V, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 A tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCBs (but without MCBs and incomer ) as required . ( DSR No. 2.5.1)
Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, "C" curve, miniature circuit breaker suitable for inductive load of Single pole in the existing MCB DB complete with connections, testing and commissioning etc. as required. ( DSR No. 2.10.1)
Providing and fixing 63 A capacity TP&N disconnector fuse switch unit inside the existing panel board with ISI marked HRC fuses including drilling holes in cubicle panel, making connections, etc. as required. ( DSR No. 2.1.2)
Installation, testing and commissioning of ceiling fan, including wiring the down rods of standard length with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable etc. as required. (DSR No. 1.44)
Installation, testing and commissioning of pre- wired, florescent fitting/compact florescent fitting of all types, complete with all accessories and tube /lamp etc. directly on ceiling/wall, including connections with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable and earthing etc.as required. (DSR No. 1.41)
Installation of exhaust fan in the existing opening, including making good the damage, connection, testing, commissioning etc. as required upto 450mm sweep. (DSR No. 1.50.1)
Supply and fixing call bell/ buzzer suitable for single phase 230V, complete as required.(DSR No.1.38)
Complete recess direct/indirect luminaire with high brightness LED and De glaring panel cover for efficient down light 4x1 ft. diffused optics 36 to 42 watt. (Make:Philips/Crompton/Havells). (Rate-MRP)
Supply of LED Batten 36-40 Watt. Make: Crompton/Havells/Philips. (Rate-MRP)
Supply of Ceiling fan 240 volt 1200mm sweep size (Market rate)make:- Orient/Havells (Rate-MRP)
Supply of Vantilation fan 250 mm. (Make- Havells/ Crompton/ Orient). (Rate-MRP)
Supply of 1.5 sq.mm. copper cable, Single core,PVCFlexible,FR .(Make:-Havells/polycab/Anchor). (Rate-MRP)
Supply of 2.5 sq.mm. copper cable, Single core,PVCFlexible,FR .(Make:-Havells/polycab/Anchor). (Rate-MRP)
Supply of 4 sq.mm. copper cable, Single core,PVCFlexible,FR .(Make:-Havells/polycab/Anchor). (Rate-MRP)
HARI ELECTRICAL CO.
SHREE KRISHANA ENGINEERING
P.K. Electricals
Cantilever Engineers
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .