Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L2₹18.1 L+₹1.1 L (6.58%)Accepted-AOC D NO 58 13 74 10 GF 111 VASAVI PARADISE GOWRI NAGAR WARD NO 42 NAD POST VISAKHAPATNAM 530009 AP | VISAKHAPATANAM | ANDHRA PRADESH | 530009 | L2 | Accepted-AOC Accepted being the Lowest Bonafide Bidder | |
| 2 | L1₹17.0 LRejected-Finance MIG 330 MADHAVADHARA VUDA COLONY VISAKHAPATNAM 530 018 | VISAKHAPATANAM | ANDHRA PRADESH | 530018 | L1 | Rejected-Finance Rejected being non Bonafide Bidder as per note of BOQ | |
| 3 | L3₹18.1 L+₹1.1 L (6.73%)Rejected-Finance 66 6 410 1 MULAGANDA HOUSING COLONY GAJUWAKA DEPOT VISAKHAPATNAM 530026 | VISAKHAPATANAM | ANDHRA PRADESH | 530026 | L3 | Rejected-Finance Rejected as the rates are higher than the Lowest Bonafide Bidder. | |
| 4 | L4₹18.2 L+₹1.2 L (7.05%)Rejected-Finance D NO LIG 98 RAJEEV NAGAR KURMANNAPALEM VISAKHAPATNAM 530 048 | VISAKHAPATANAM | ANDHRA PRADESH | 530048 | L4 | Rejected-Finance Rejected as the rates are higher than the Lowest Bonafide Bidder. | |
| 5 | L5₹19.9 L+₹3.0 L (17.4%)Rejected-Finance | L5 | Rejected-Finance Rejected as the rates are higher than the Lowest Bonafide Bidder. |
| Sl No | Description | Qty | Unit | MONITOR ENGINEERING WORKS H6 | GVR ENGINEERING WORKS H5 | Jessica Engineering Works H4 | SRIVALLI ENGINEERS H1 | M/s.DSRK CONSTRUCTIONS H9 | G T SERVICES H8 | GVR CONSTRUCTIONS H7 | K C ENTERPRISES H2 | B.Veerabhadra Rao H3 |
|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 1.00 | Manning and operation of 11kV Substation of HT 11KV RMU, Distribution Transformers, 02,04 Pole Structures & Perimeters lighting system structures, LT Panels including connected E/M items for smooth functioning of AOB Rambilli area by technician & helper for eight hours shift. (E/M Installations to be operate for the uninterrupted power supply as per standred norms)
Note:- No of Person required - 02 person (01 Skilled Electrician & 01 Helper )
3 shift per day
Ist shift (0600 Hrs to 1400 Hrs) = 01 Elect & 01 Helper
IInd shift (1400 Hrs to 2200 Hrs) = 01 Elect & 01 Helper
IIIrd shift (2200 Hrs to 0600 Hrs) = 01 Elect & 01 Helper | 1,002 | Per shift of 08 hrs | 1,672 ₹16,75,344 | 1,975 ₹19,78,950 | 2,050.02 ₹20,54,120.04 | 2,050 ₹20,54,100 | 1,600 ₹16,03,200 Lowest | 1,806 ₹18,09,612 | 1,807 ₹18,10,614 | 2,058 ₹20,62,116 | 2,000 ₹20,04,000 |
| 1.10Note:-It is mandatory that provision of statutory laws relating to minimum Wages as per GOI Chief labour commissioner (C) New Delhi latest letter , EPF@ 12% of labour rate, Bonus @ 8.33 % , ESIC @ 3.25 % , GST @ 18% taxes as applicable shall be strictly adhered to by the contractor and his quoted rates shall be deemed to include these factors. If any bidders quotated their rates below minimum wages with EPF, ESIC , Bonus with applicable GST, such bid shall be treated as willfull negligence by the bidder and shall be considered non-bonafied and rejected during financial evaluation. Note for Sl No.1 :- The rate shall be quoted above deemed to be inclusive of the fwg:- (i) Day to Day E/M compliants of AOB Rambilli to be attended and the job card shall be signed by the respective user as issued by JE E/M complete all as specified and directed.(i) Visual Cheking (a) All equipments/items to be visually checked by the operator and service ability report to be filled in log sheet. Any fault or unserviceable of eqpts to be informed to JE E/M otherwise EIC. (ii) Monitoring of Eqpts | ||||||||||||
| 1.20(a) Daily log sheet shall be maintained by the contractor & the log sheet shall be provided by the contractor as per Performa given by the department be inspected thoroughly before switching on. (b) Maintaining duty log sheet and checking all parameter of metering devices. (c) Checking of various meters for measurement of current, voltage etc, including recording of these readings in log sheet and also recording of any unwanted signal of spark, sound in switchgears/eqpts etc. (d) Switchgear and equipments shall be properly cleaned. (e) Dress shall be provided for every shift operator (dress colour to be approve prior approval of Engr-in-Charge). (f) One mobile phone with sim to be provided at site for commnication and fault rectification. (g) Minor complaints to be attend by the techanician given by the concerned JE/EIC. (h) Conveyance facility to be provided by the contractor in station premises for attending the faults/complaints. (j)The contractor shall provide Bio-metric attendance machine for attendance of labours / staffs. The payment will be made on Biometric attendance report | ||||||||||||
| 2.00 | Material and labour for point wiring for One light point/fan/socket 5Amps controlled by one switch with PVC insulated 1.5 sqmm FRLS multistrand copper conductor cable (Phase - Red, Neutral - Black) 1100 volts grade drawn into and including concealed rigid non metallic PVC conduit medium grade not less than 20 mm dia ISI marked ivory colour with all conduit fittings and fixing accessories including sunken galvanized pressed steel terminal boxes of thickness 1.12 mm covered with 3 mm thick phenolic laminated white sheet cover for mounting electrical fittings, fixtures, accessories etc and 1.5 sqmm FRLS multistrand copper conductor cable (Green) as continuous earth wire incl taking down old unserviceable complete all as specified and directed by GE / Engineer-in-Charge. | 5 | Point | 723 ₹3,615 | 85 ₹425 | 2 ₹10 | 650 ₹3,250 | 800 ₹4,000 | 1 ₹5 Lowest | 3 ₹15 | 330 ₹1,650 | 350 ₹1,750 |
| 3.00 | Material and labour for submain wiring alongwith earth continuity conductor with PVC insulated FRLS multistrand copper conductor cable (Phase - Red, Neutral - Black, Earth - Green) drawing into and including concealed/surface reqd at site including rigid non metallic PVC conduit, medium grade, ISI marked ivory colour with all conduit accessories and taking down old u/s complete size of 2x2.5 sq mm + 1x2.5 sq mm (earth) in 20 mm dia conduit complete . | 10 | Running Metre | 323 ₹3,230 | 75 ₹750 | 1 ₹10 Lowest | 180 ₹1,800 | 600 ₹6,000 | 1 ₹10 Lowest | 5 ₹50 | 130 ₹1,300 | 100 ₹1,000 |
| 4.00 | Material and labour for submain wiring alongwith earth continuity conductor with PVC insulated FRLS multistrand copper conductor cable (Phase - Red, Neutral - Black, Earth - Green) drawing into and including concealed/surface reqd at site including rigid non metallic PVC conduit, medium grade, ISI marked ivory colour with all conduit accessories and taking down old u/s complete size of 2x4 sq mm + 1x4 sq mm (earth) in 20 mm dia conduit. | 10 | Running Metre | 343 ₹3,430 | 100 ₹1,000 | 2 ₹20 | 200 ₹2,000 | 1,200 ₹12,000 | 1 ₹10 Lowest | 10 ₹100 | 150 ₹1,500 | 160 ₹1,600 |
| 5.00 | Supplying & fix in replacement of powder coated, CRCA steel sheet MCB distribution board (minimum thickness 1.2 mm & constructed as per IS : 8623), degree of protection IP 43 - IK 09 with metal double door, recess mounted, having insulated 100 amp tinned copper bus bar, neutral busbar, earth bar, din bar, detachable gland plate, interconnection, earthing connection, blanking plates in unused spaces etc as required for SPN 240 Volts, 8 Ways complete and all as specified. | 1 | Each | 4,223 ₹4,223 | 400 ₹400 | 2 ₹2 Lowest | 2,000 ₹2,000 | 5,000 ₹5,000 | 2 ₹2 Lowest | 100 ₹100 | 1,200 ₹1,200 | 1,300 ₹1,300 |
| 6.00 | Supplying & fix in replacement of powder coated, CRCA steel sheet MCB distribution board (minimum thickness 1.2 mm & constructed as per IS : 8623), degree of protection IP 43 - IK 09 with metal double door, recess mounted, having insulated 100 amp tinned copper bus bar, neutral busbar, earth bar, din bar, detachable gland plate, interconnection, earthing connection, blanking plates in unused spaces etc as required for TPN 415 Volts, 4 Ways complete and all as specified. | 1 | Each | 3,443 ₹3,443 | 850 ₹850 | 1 ₹1 Lowest | 2,200 ₹2,200 | 5,000 ₹5,000 | 4 ₹4 | 50 ₹50 | 1,450 ₹1,450 | 3,333 ₹3,333 |
| 7.00 | Supplying and and replacement of as per load requirement 'C' series MCBs of breaking capacity 10 KA, ISI marked including required wiring connections with copper lugs of suitable size provided in MCB DBs of following ratings:- Note for MCBs & MCB DBs:- MCB DBs shall be fixed on wall in flush pattern by cutting the wall and making good disturbed surfaces of Single pole 6 to 32 Amp | 8 | Each | 373 ₹2,984 | 295 ₹2,360 | 1 ₹8 Lowest | 171 ₹1,368 | 600 ₹4,800 | 1 ₹8 Lowest | 20 ₹160 | 130 ₹1,040 | 150 ₹1,200 |
| 8.00 | Supplying and and replacement of as per load requirement 'C' series MCBs of breaking capacity 10 KA, ISI marked including required wiring connections with copper lugs of suitable size provided in MCB DBs of following ratings:- Note for MCBs & MCB DBs:- MCB DBs shall be fixed on wall in flush pattern by cutting the wall and making good disturbed surfaces of Double pole 40 to 63 Amp | 1 | Each | 702 ₹702 | 205 ₹205 | 2 ₹2 | 800 ₹800 | 700 ₹700 | 1 ₹1 Lowest | 30 ₹30 | 280 ₹280 | 800 ₹800 |
Tender Value
₹21.0 L
EMD Value
₹41,920
Closing Date
24 Nov 2025, 11:00 amClosed
CWE (WORKS) 2 VIZAG
CWE (WORKS) 2 VIZAG
OUTSOURCING OF MANPOWER FOR MANNING AND OPERATION OF 11KV SUBSTATION AND ELECTRICAL DISTRIBUTION COMPLETE AT AOB RAMBILLI
2025_MES_737741_1
CWE WKS-2 VIZAG/TOKEN 03 OF 2025-26
Open Tender
Civil Works
Works
335 days
RAMBILLI NEAR VISAKHAPATNAM
AS PER NIT
7 documents required · 7 mandatory
₹500
DGNP VISAKHAPATNAM
₹41,920
Yes
8 Jan 2026
31 Oct 2025
1 Dec 2025
31 Oct 2025
24 Nov 2025
17 Nov 2025
31 Oct 2025 - 5 Nov 2025
Amount
Manning and operation of 11kV Substation of HT 11KV RMU, Distribution Transformers, 02,04 Pole Structures & Perimeters lighting system structures, LT Panels including connected E/M items for smooth functioning of AOB Rambilli area by technician & helper for eight hours shift. (E/M Installations to be operate for the uninterrupted power supply as per standred norms) Note:- No of Person required - 02 person (01 Skilled Electrician & 01 Helper ) 3 shift per day Ist shift (0600 Hrs to 1400 Hrs) = 01 Elect & 01 Helper IInd shift (1400 Hrs to 2200 Hrs) = 01 Elect & 01 Helper IIIrd shift (2200 Hrs to 0600 Hrs) = 01 Elect & 01 Helper
Note:-It is mandatory that provision of statutory laws relating to minimum Wages as per GOI Chief labour commissioner (C) New Delhi latest letter , EPF@ 12% of labour rate, Bonus @ 8.33 % , ESIC @ 3.25 % , GST @ 18% taxes as applicable shall be strictly adhered to by the contractor and his quoted rates shall be deemed to include these factors. If any bidders quotated their rates below minimum wages with EPF, ESIC , Bonus with applicable GST, such bid shall be treated as willfull negligence by the bidder and shall be considered non-bonafied and rejected during financial evaluation. Note for Sl No.1 :- The rate shall be quoted above deemed to be inclusive of the fwg:- (i) Day to Day E/M compliants of AOB Rambilli to be attended and the job card shall be signed by the respective user as issued by JE E/M complete all as specified and directed.(i) Visual Cheking (a) All equipments/items to be visually checked by the operator and service ability report to be filled in log sheet. Any fault or unserviceable of eqpts to be informed to JE E/M otherwise EIC. (ii) Monitoring of Eqpts
(a) Daily log sheet shall be maintained by the contractor & the log sheet shall be provided by the contractor as per Performa given by the department be inspected thoroughly before switching on. (b) Maintaining duty log sheet and checking all parameter of metering devices. (c) Checking of various meters for measurement of current, voltage etc, including recording of these readings in log sheet and also recording of any unwanted signal of spark, sound in switchgears/eqpts etc. (d) Switchgear and equipments shall be properly cleaned. (e) Dress shall be provided for every shift operator (dress colour to be approve prior approval of Engr-in-Charge). (f) One mobile phone with sim to be provided at site for commnication and fault rectification. (g) Minor complaints to be attend by the techanician given by the concerned JE/EIC. (h) Conveyance facility to be provided by the contractor in station premises for attending the faults/complaints. (j)The contractor shall provide Bio-metric attendance machine for attendance of labours / staffs. The payment will be made on Biometric attendance report
Material and labour for point wiring for One light point/fan/socket 5Amps controlled by one switch with PVC insulated 1.5 sqmm FRLS multistrand copper conductor cable (Phase - Red, Neutral - Black) 1100 volts grade drawn into and including concealed rigid non metallic PVC conduit medium grade not less than 20 mm dia ISI marked ivory colour with all conduit fittings and fixing accessories including sunken galvanized pressed steel terminal boxes of thickness 1.12 mm covered with 3 mm thick phenolic laminated white sheet cover for mounting electrical fittings, fixtures, accessories etc and 1.5 sqmm FRLS multistrand copper conductor cable (Green) as continuous earth wire incl taking down old unserviceable complete all as specified and directed by GE / Engineer-in-Charge.
Material and labour for submain wiring alongwith earth continuity conductor with PVC insulated FRLS multistrand copper conductor cable (Phase - Red, Neutral - Black, Earth - Green) drawing into and including concealed/surface reqd at site including rigid non metallic PVC conduit, medium grade, ISI marked ivory colour with all conduit accessories and taking down old u/s complete size of 2x2.5 sq mm + 1x2.5 sq mm (earth) in 20 mm dia conduit complete .
Material and labour for submain wiring alongwith earth continuity conductor with PVC insulated FRLS multistrand copper conductor cable (Phase - Red, Neutral - Black, Earth - Green) drawing into and including concealed/surface reqd at site including rigid non metallic PVC conduit, medium grade, ISI marked ivory colour with all conduit accessories and taking down old u/s complete size of 2x4 sq mm + 1x4 sq mm (earth) in 20 mm dia conduit.
Supplying & fix in replacement of powder coated, CRCA steel sheet MCB distribution board (minimum thickness 1.2 mm & constructed as per IS : 8623), degree of protection IP 43 - IK 09 with metal double door, recess mounted, having insulated 100 amp tinned copper bus bar, neutral busbar, earth bar, din bar, detachable gland plate, interconnection, earthing connection, blanking plates in unused spaces etc as required for SPN 240 Volts, 8 Ways complete and all as specified.
Supplying & fix in replacement of powder coated, CRCA steel sheet MCB distribution board (minimum thickness 1.2 mm & constructed as per IS : 8623), degree of protection IP 43 - IK 09 with metal double door, recess mounted, having insulated 100 amp tinned copper bus bar, neutral busbar, earth bar, din bar, detachable gland plate, interconnection, earthing connection, blanking plates in unused spaces etc as required for TPN 415 Volts, 4 Ways complete and all as specified.
Supplying and and replacement of as per load requirement 'C' series MCBs of breaking capacity 10 KA, ISI marked including required wiring connections with copper lugs of suitable size provided in MCB DBs of following ratings:- Note for MCBs & MCB DBs:- MCB DBs shall be fixed on wall in flush pattern by cutting the wall and making good disturbed surfaces of Single pole 6 to 32 Amp
Supplying and and replacement of as per load requirement 'C' series MCBs of breaking capacity 10 KA, ISI marked including required wiring connections with copper lugs of suitable size provided in MCB DBs of following ratings:- Note for MCBs & MCB DBs:- MCB DBs shall be fixed on wall in flush pattern by cutting the wall and making good disturbed surfaces of Double pole 40 to 63 Amp
Supplying and and replacement of as per load requirement 'C' series MCBs of breaking capacity 10 KA, ISI marked including required wiring connections with copper lugs of suitable size provided in MCB DBs of following ratings:- Note for MCBs & MCB DBs:- MCB DBs shall be fixed on wall in flush pattern by cutting the wall and making good disturbed surfaces of Four pole 40 to 100 Amp
Supplying and replacement of MCCB four pole, 125 amps, 16 KA thermally adjustable between 70 to 100% including 4 spreader link set of same make as that of MCCB for connection, required lugs etc complete. Make - Legrand cat ref no 625329 or equivalent in L&T or Moeller HPL as approved.
Supplying and fixing rigid non metallic PVC conduit medium grade ISI marked ivory colour along with accessories in recess including cutting the wall and making good disturbed surface of 20mm dia
Supplying and fixing rigid non metallic PVC conduit medium grade ISI marked ivory colour along with accessories in recess including cutting the wall and making good disturbed surface of 25mm dia
Supply only Switch piano type 6Amp single way for day to day complaints
Supply only Switch piano type 16Amp single way for day to day complaints
Supply only Socket outlet 2 in 1, 2 & 3 pin, 6 amp, flush type for day to day complaints
Supply only Socket outlet 2 in 1, 3 pin 6 & 16 amp flush type for day to day complaints
Supply only Insulation tape industrial type for day to day complaints
Supply only Tube rod 36W T8 FTL for day to day complaints
Supply only Starter 230V for 18W/20W/36W/40W for day to day complaints
Supply Electronic ballast suitable for FTL lamp 1x36W for day to day complaints
Supply only Electronic ballast suitable for FTL lamp 2x24W for day to day complaints
Supply only Tube rod 24W for day to day complaints
Supply only Flexible wire 1.5Sqmm 2 core for day to day complaints
Supply only Igniter for day to day complaints
Supply only Capacitors for search light for day to day complaints
Supply only Switch bell push single way for day to day complaints
K C ENTERPRISES (BID ID -3476959)
B.Veerabhadra Rao (BID ID -3486236)
Jessica Engineering Works (BID ID -3481132)
GVR ENGINEERING WORKS (BID ID -3481052)
MONITOR ENGINEERING WORKS (BID ID -3480722)
GVR CONSTRUCTIONS (BID ID -3480386)
G T SERVICES (BID ID -3479289)
M/s.DSRK CONSTRUCTIONS (BID ID -3486446)
stage.html
html • 0.06 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.60 MB
TenderDocuments.pdf
Tender Documents • 0.51 MB
IP.pdf
Additional Documents • 0.50 MB
BOQ_826064.xls
BOQ • 0.36 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .