Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹17.7 LAccepted-AOC | L1 | Accepted-AOC being L1 | |
| 2 | Rejected-Technical 30551 STREET NO 5 9 JOGI NAGAR BATHINDA 151001 | BATHINDA | PUNJAB | 151001 | - | Rejected-Technical Documents not submitted as per NIT. |
Tender Value
₹22.2 L
EMD Value
₹44,320
Closing Date
18 Apr 2022, 5:00 pmClosed
AGM (Engg-C)
Civil Airport, Chandigarh
Repair of Damaged Roof and Side Canopy Portion of Old Terminal Building at Chandigarh Airport
2022_AAI_111146_1
AAI/CHD/ENGG(C)/Roof Canopy/2022
Open Tender
Civil Works
Item Rate
90 days
Chandigarh Airport
As per NIT
2 documents required · 2 mandatory
₹1,180
₹44,320
13 Sept 2022
28 Mar 2022
19 Apr 2022
29 Mar 2022
18 Apr 2022
29 Mar 2022
29 Mar 2022 - 14 Apr 2022
Amount
Providing and fixing of double skinned insulated roofing system in pre-painted galvalume using Standing Seam Profile Sheeting comprising of following layers- 1. Liner/ Inner sheet with crest height 28-30mm and pitch distance 195-200mm.The end rib shall have anti capillary groove to avoid any ingress of water through the side lap minimum pitch of 250mm c/c in 0.50mm TCT color coated galvalume AZ150 in minimum 550MPa YS. The sheet shall be fixed on the main purlin with SDST screw with EPDM washers confirming to AS3566 class 3 specs. Color-SMS coated 20+5/5+5 2. Vapour Control layer –polythene sheet 0.20 mm thick over inner sheet to prevent condensation occurring due to variance in temperature. 3. Halters/Sub girt (GI 50x100x50x1.6mm) to be fixed in between two sheets to support the outer sheet on which top sheet shall be fixed. 4. Two layer of 50mm Rockwool insulation having density minimum 48kg/m3. (Total thickness 100 mm) 5. Outer sheet shall be Standing Seam Profile sheet with non-piercing, concealed fastening roofing system manufactured from pre painted galvalume sheet (PPGL) of minimum 0.60mm TCT, 550Mpa, AZ150GSM, RMP Coated 20+5 complete with ziplock arrangement. The galvalume sheet should be of make LLOYD/TATA/JSW/EVEREST/JINDAL coil, Height of the Building is approx. 20 meter, actual site photographs are attached showing the scope of work to be carried out and gives an understanding to quote their rate. However, it is advisable to inspect the site at Chandigarh Airport before quoting the rate. The item contains complete work including Scaffolding, safety measures to be taken at height upto 20metre etc. The work shall be carried out as per manufactures specification and directions of Engineer-in-charge. Nothing extra shall be paid on any account. Specifications and color shall match with the existing Roofing system as mentioned above. NOTE: 1. Item includes supplying, installation and fixing of PPGL sheet including cost of system accessories insulation, vapour barrier, liner sheet, halters, flashing, fasteners, gaskets, brackets screws rivets, sealants, inner clousre fillers, fixtures, all machineries, labour involved in all the operations described above including charges of all lifts, leads, transportation, scaffolding, centering, shuttering, boom lift machines, profiling machine and all the taxes except GST. The above work is to be carried out by a specialised agency approved by the Engineer-in-charge. Nothing extra shall be paid on this account. The approximate area of the work is 650 Sqm. 2. The above item also includes scaffolding, boomlift machine or other necessary arrangements required for replacement of old sheet and installation of new sheet. Nothing extra shall be paid on this account. 3. The work will be executed by the specialized agency only and being specialized agency, he has to ensure the overall stability of insulated roofing system along with junctions/connections with the existing roofing system. 4. Agency will submit the Guarantee Bond for safety and stability of the double skinned insulated roofing system for a period of 5 (five) years after completion of the work. 5. Defect Liability Period : 5 Years (50% of Security deposit will be released after 1 year & balance 50% will be released after successful completion of defect liability period of 5 years from the date of actual completion of work.) 6. For payment purpose, only area of outer profile sheet after erection in straight/curved shape (finished work) shall be measured in Sqm upto 2 decimals. Nothing extra shall be paid on any account. 7. The color and profiling of inner & outer sheet should be similar to existing one.
Deduct for taking away of dismantled sheet material from the existing roof of the building. The material so received shall be the property of contractor after dismantling duly weighed/measured before removing from the site in the presence of Engineer-in-charge or his authorised representative all complete. NOTE: Necessary deduction will be made from the running bill of the contractor as per the actual measurement and the rate quoted by the contractor.
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .