Executive Engineer, Mechanical Division,PWD, Aga
Executive Engineer, Mechanical Division,PWD, Agartala
Annual Maintenance of Non VRF AC system of New Secretariat Building, Tripura Legislative Assembly Building, High Court of Tripura Building, Raj Bhavan and Chief Justice Bungalow Agartala, Tripura for 01 year
2023_CEPWD_40177_1
20/EE/DNIeT/MECH.DIVN/AGT/2023
Open Tender
Electrical Works
Works
365 days
AGARTALA
Please refer Tender documents.
7 documents required · 7 mandatory
₹1,000
₹18,658
12 Dec 2023
20 Jul 2023
5 Aug 2023
20 Jul 2023
5 Aug 2023
20 Jul 2023
Amount
Complete servicing of AC machines (Indoor & outdoor Unit) as per direction of the Engineer-in-charge.
(I)1.0/1.2/1.5/2.0 TR High wall split type AC.
(II)1.5 TR window type AC.
(III) 2.5/3.0/4.0/4.5 TR High wall Split, cassette and vertical AC
Leak testing of condenser & evaporator unit for performance and pressure testing etc and repair with brazing as per direction of the Engineer-in-charge.
(I)1.0/1.2/1.5/2.0 High wall split and window type AC.
(II)2.5/3.0/4.5 TR High wall split, cassette and vertical type AC
Charging of fresh refrigerant gas (R-22) for 1.0/1.2/1.5/2.0/3.0/4.0 TR capacity High wall split/window/cassette / vertical AC system as per direction of the Engineer-in-charge.
Charging fresh refrigerant gas (R-410) for 1.5/2.0/3.0 TR High wall split and cassette AC system as per direction of the Engineer-in-charge.
Charging fresh refrigerant gas (R-32) for 1.5/2.0/2.5/3.0 TR High wall split type AC system as per direction of the Engineer-in-charge.
Charging fresh refrigerant gas for refrigerator (R-134,Hydro Carbon, R-600, R-190) as per direction of the Engineer-in-charge.
Providing, fitting and fixing of hermetically sealed compressor for replacement of defective one as per direction of the Engineer-in-charge. (With one year warranty)
(I) 1.0 TR capacity High wall split type AC.
(II) 1.2 TR capacity High wall split type AC.
(III) 1.5 TR capacity High wall split type AC.
(IV) 1.5 TR capacity window type AC.
(V) 2.0 TR capacity High wall split and cassette type AC.
(VI)2.5 TR capacity High wall split type AC.
(VII)3.0 TR capacity High wall split and cassette type AC.
(VIII)4.0 TR capacity vertical split type AC.
Providing, fitting and fixing of hermetically sealed compressor for refrigerator as per direction of the Engineer-in-charge. (With one year warranty)
Providing, fitting and fixing of hermetically sealed copper condenser unit for replacing old one as per direction of the Engineer-in-charge.
(I) 1.0/1.2/1.5 TR capacity High wall split and window type AC.
(II) 2.0/2.5 TR capacity High wall split and cassette type AC.
(III) 3.0/4.0 TR capacity High wall split and vertical type AC.
Fitting, fixing of blower motor of Ac systems after rewinding I/C necessary replacement of bush, shaft etc with complete varnishing as per direction of the Engineer-in-charge.
Repair/ replacement of defective scroll motor (A.C)of indoor unit split type AC system as per direction of the Engineer-in-charge.
Repair/ replacement of defective scroll motor (D.C) of indoor unit for inverter technology split type AC system as per direction of the Engineer-in-charge.
Repair/ replacement of defective swing motor of indoor unit split type AC system as per direction of the Engineer-in-charge.
Repair/ replacement of defective relay of split type AC system as per direction of the Engineer-in-charge.
Replacement of air filter of split type and window type AC system as per direction of the Engineer-in-charge.
Repair/replacement of defective indoor PCB circuit as per direction of the Engineer-in-charge.
(I)1.0/1.2/1.5/2.0/2.5/3.0 TR split type high wall AC.
(II)2.0/3.0 TR cassette type AC.
(III)4.50TR vertical type AC.
Repair/ replacement of defective outdoor PCB circuit for inverter technology split type AC system as per direction of the Engineer-in-charge.
Repair/ replacement of defective PCB transformer for split type AC system as per direction of the Engineer-in-charge.
Repair/ replacement of defective pump motor for cassette type AC system as per direction of the Engineer-in-charge.
Supply and installation of additional length of copper pipe of 5/8” diameter and ¼” diameter for suction and liquid line with insulation and necessary wiring (with three pin electrical plug) to connect the indoor and outdoor unit as per direction of the Engineer-in-charge.
Supply and installation of additional length of copper pipe of 5/8” diameter and 3/8’ diameter for suction and liquid line with insulation and necessary wiring (with three pin electrical plug) to connect the indoor and outdoor unit as per direction of the Engineer-in-charge.
Fabrication of M.S platform for placement of condensing unit by using M.S angel of (50x50x5)mm/(65x65x5)mm size base plate, nuts & bolts/universal bracket (GSS) for ODU of split type AC system including all accessories for on-site installation i/c painting, fitting, fixing grouting by cement mixer as per direction of the Engineer-in-charge.
Dismantling and re-installation of 1.0/1.2/1.5/2.0/2.5/3.0 TR window, split and cassette type AC system as per direction of the Engineer-in-charge.
Providing, fitting and fixing of G.C.I shed of two parts slanting with ridge and necessary structure by using M/S angle of (30x30x5) mm size M.S flat (18x5) mm size over condensing unit i/c painting and finishing as per direction of the Engineer-in-charge.
Providing hard/ coil PVC pipe of good quality of 25 mm diameter including necessary clamping and fitting for draining of condensate water from indoor unit as per direction of the Engineer-in-charge
Repair/ replacement of defective thermostat for split type AC system as per direction of the Engineer-in-charge.
Repair/ replacement of defective 25 mfd capacitor for window type AC system as per direction of Engineer-in-charge.
Repair/ replacement of defective 36 mfd capacitor for window type AC system as per direction of the Engineer-in-charge.
Repair/ replacement of defective 45 mfd capacitor for split type AC system as per direction of the Engineer-in-charge.
Repair/ replacement of defective 50 mfd capacitor for split type AC system as per direction of the Engineer-in-charge.
Repair/ replacement of defective (80-120) mfd capacitor for window type AC system as per direction of the Engineer-in-charge.
Repair/ replacement of defective terminal clip as per direction of the Engineer-in-charge.
Providing fitting and fixing of PVC tape (Black tap) as per direction of the Engineer-in-charge.
Repair/ replacement of defective thermostat for window type AC system as per direction of the Engineer-in-charge.
Repair/ replacement of defective starting relay for window type AC system as per direction of the Engineer-in-charge.
Repair/ replacement of defective capillaries/ dryer for window and split type AC system as per direction of the Engineer-in-charge.
Supply and installation of additional length of electrical copper wire 4 mm size with casing size 01 (One) inch including other materials to connect outdoor unit with electrical panel as per direction of the Engineer-in-charge.
Repair/ replacement of defective fan capacitor 2.0/2.5/4.0/5.0 mfd as per direction of the Engineer-in-charge.
Repair/ replacement of defective fan blade of outdoor unit of window, split, cassette and vertical type AC system as per direction of the Engineer-in-charge.
Repair/ replacement of defective connector for split type AC system as per direction of the Engineer-in-charge.
Repair/ replacement of defective remote with battery for window, split, cassette and vertical type AC system as per direction of the Engineer-in-charge.
Repair/ replacement of defective coil sensor for split type AC system as per direction of the Engineer-in-charge.
Repair/ replacement of defective room sensor for split type AC system as per direction of the Engineer-in-charge.
Repair/ replacement of defective display sensor for split type AC system as per direction of the Engineer-in-charge.
Repair/ replacement of defective nitral tape (Arrow tape) as per direction of the Engineer-in-charge.
Providing, fitting and fixing cooling coil for refrigerator as per direction of the Engineer-in-charge. (With one year warranty)
Providing, fitting and fixing fan motor for double door refrigerator as per direction of the Engineer-in-charge.
Providing, fitting and fixing timer for double door refrigerator as per direction of the Engineer-in-charge.
Providing, fitting and fixing sensor for double door refrigerator as per direction of the Engineer-in-charge. (With one year warranty)
Providing, fitting and fixing heater coil for double door refrigerator as per direction of the Engineer-in-charge.
Repair/ replacement of defective contactors for split type AC system as per direction of the Engineer-in-charge.
R.P.ELECTRONICS
stage.html
html • 0.04 MB
tech_eval.pdf
fin_eval.pdf
aoc.pdf
finance_40794.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .