Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹67.8 LAccepted-AOC | L1 | Accepted-AOC Being lowest bidder | |
| 2 | L2₹72.4 L+₹4.6 L (6.86%)Rejected-Finance 304 VELENTINE TOWER FILM CITY ROAD OPP WAGESWARI TEMPLE MALAD E MUMBAI 400097 | MUMBAI SUBURBAN | MAHARASHTRA | 400097 | L2 | Rejected-Finance Not Quoted Lowest | |
| 3 | L3₹72.7 L+₹4.9 L (7.26%)Rejected-Finance 0 0 RAMNAGAR FATEHPUR ROAD KADIRABAD GRAM BUDHWAL PARGANA AND TEHSIL RAMNAGAR BARABANKI UTTAR PRADESH 225202 | BARABANKI | UTTAR PRADESH | 225202 | L3 | Rejected-Finance Not Quoted Lowest | |
| 4 | L4₹75.7 L+₹7.9 L (11.7%)Rejected-Finance 2 65 GORWA UDAYPARK SOCIETY REFINERY ROAD VILLAGE TOWN VADODARA CITY VADODARA VADODARA GUJARAT 390016 INDIA | VADODARA | GUJARAT | 390016 | L4 | Rejected-Finance Not Quoted Lowest | |
| 5 | L5₹78.2 L+₹10.4 L (15.3%)Rejected-Finance OLD JAIL ROAD NEAR JILA GARDEN RAJKOT 360001 | RAJKOT | GUJARAT | 360001 | L5 | Rejected-Finance Not Quoted Lowest |
Tender Value
₹98.7 L
EMD Value
₹2.0 L
Closing Date
4 Apr 2024, 3:00 pmClosed
AGM, (E-E), AAI, Surat Airport
AGM, (E-E), AAI, Surat Airport
Supply and Laying of LT Cables , SITC of SPD and other Electrical works at Surat International Airport, Surat.
2024_AAI_188127_1
AAI/SRT/AGM(E-E)/eNIT-10/23-24
Open Tender
Electrical Works
Item Rate
180 days
AAI, Surat Airport
Please refer Tender documents.
19 documents required · 19 mandatory
₹1,180
₹2.0 L
11 Oct 2024
15 Mar 2024
5 Apr 2024
15 Mar 2024
4 Apr 2024
15 Mar 2024
15 Mar 2024 - 21 Mar 2024
Amount
Supply of following sizes of XLPE insulated PVC sheathed, aluminium conductor, armoured, power cable of 1.1 KV grade conforming to IS 7098 (Part I), 1988 amended upto date.
3.5 x 400 Sqmm
3.5 x 300 Sqmm
3.5 x 240 Sqmm
3.5 x 120 Sqmm
3.5 x 70 Sqmm
4 x 16 Sqmm
4 x 10 Sqmm
Supply of 2 X 25 sq.mm Aluminium conductor PVC insulated, PVC sheathed (Inner sheath extruded) galvanised steel strip armoured anti termite and anti rodent treated under ground cable of 5 KV grade confirming to IS 1554 as amended upto date and as specified in particular specification.
Supply of 110mm (OD-110mm, PN 8, PE 80) ISI marked HDPE pipe, conforming to IS 4984, along with all acessories like socket, bend, couplers as required including fitting, cutting, jointing etc., etc. complete in all respect as per direction of Engineer-in-Charge. required.
Supply of 50 mm (OD-50mm, PN 06, PE 63) ISI marked HDPE pipe, conforming to IS 4984, along with all accessories like socket, bend, couplers complete as required
Supply of 40 mm (OD-40mm, PN 06, PE 63) ISI marked HDPE pipe, conforming to IS 4984, along with all accessories like socket, bend, couplers complete as required
Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required. (Above 185 sq. mm and upto 400 sq. mm (clamped with 40x3mm MS flat clamp)
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 kV/ 5kV grade of following size in the existing masonry open duct as required.
Upto 35 sqmm
Above 185 sq. mm and upto 400 sq. mm
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 kV / 5 kV grade of following size in the existing RCC/ HUME/ METAL/HDPE pipe as required.
Upto 35 sqmm
Above 185 sq. mm and upto 400 sq. mm
laying of 110 mm (OD-110mm,PN 06,PE 63) ISI marked HDPE pipe, along with all accessories like socket, bend, couplers, suitable size PP rope as required including fitting, cutting, jointing with HDD trenchless method direct in ground (up to 6 mtrs below ground level ) in all type of soil etc complete in all respect as per direction of Engineer-in-Charge. required.
laying of 110 mm (OD-110mm,PN 06,PE 63) ISI marked HDPE pipe, along with all accessories like socket, bend, couplers, suitable size PP rope as required including fitting, cutting, jointing direct in ground (up to 75cm below ground level ) in all type of soil i/c excavation & re-filling the trench but excluding sand cushioning and protective covering etc complete in all respect as per direction of Engineer-in-Charge. required.
Laying of 50 mm (OD-50mm,& ID-39mm nominal) ISI marked HDPE pipe, along with all accessories like socket, bend, couplers, suitable size PP rope as required including fitting, cutting, jointing direct inground (75cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc,complete as required in all respect as per direction of Engineer-in-Charge. required.
Laying of 40 mm (OD-40mm,& ID-39mm nominal) ISI marked HDPE pipe, along with all accessories like socket, bend, couplers, suitable size PP rope as required including fitting, cutting, jointing direct inground ( upto 75cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc,complete as required in all respect as per direction of Engineer-in-Charge. required.
Supplying and making straight through joint with heat shrinkable kit including ferrules and other jointing materials for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV/5kV grade as required
3.5 X 400 sqmm
2x25 sq mm 5KV grade airfield cable
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 kV/5kV grade as required.
3.5 X 400 sqmm (82 mm) 1.1 KV
2x25 sq mm 5KV grade airfield cable
2 X 25 sq. mm (22mm) 1.1 KV
4 X 10 sq. mm (25mm) 1.1 KV
Replacement of defective SPD installed in the existing panel by Supply, Installation, Testing & Commissioning of Three Phase modular type Surge Protection Device (CLASS- B,1,Stage-1/primary) with minimum lightning impulse current (Iimp) of 100KA (10/350 micro seconds) neutral to earth, 50 KA (10/350 micro sec) line to neutral ,limiting voltage less than 1.5 KV,to be installed in parrallel at the mains panel of power entry point including making connection of surge protection device in parallel to the busbar of the main electrical panel using 16 Sq mm single core PVC insulated flexible copper conductor cables, in IP55 grade powder coated metal enclosure with 63 Amp. service / bypass changeover switch, on the mains power entry point at the incomers including all accessories such as suitable rating , MCBs, making end terminations, fixing/mounting arrangement of SPD , dismantling of existing defective SPD ,modifications in the existing panels by cutting the section,wiring/cable connection modification if required as per the site requirement etc complete as required as per enclosed specification.
Replacement of defective MOV based Series Power Filter installed in the existing panel by Supply, Installation, Testing & Commissioning of 32 Amps Multistage 1 phase Series Power Filter with neutral protection with MOV 40 KA + 25 KA rating in IP55 grade Powder coated metal enclosure with a 63 Amps service/ bypass changeover switch and 16 Sq mm single core PVC insulated flexible copper conductor cables for inter connection, end termination,MCB, fixing/mounting arrangement, of complete assembly to be installed at input of the UPS/Voltage stabilizer in series,dismantling of existing defective MOV based Series Power Filter ,modifications in the existing panels by cutting the section,wiring/cable connection modification if required as per the site requirement etc.complete as required as per enclosed specification.
Supply, Installation, Testing & Commissioning of Isolation Transformer of Single Phase 5 kVA rating as per the technical specification etc complete as required.
Providing chemical earthing by using ISOGEL earth enhanced compound of 20 kgs, advanced chemical earth ISOROD made with copper tube of 2.5” dia, 8 fts long, 1.6 mm thick installed vertically or horizontally as per the site conditions complete with flanges bends top cover heavy duty plastic inspection chamber including excavation and refilling etc as required.
Making suitable size hole in existing MS transformer housing box with approx. 10mm thickness by gas cutting machine, suitable for connecting the 40 mm dia HDPE pipe including plugging of the extra opening by using suitable waterproof sealant/adhesive etc complete as required.
Laying of HDPE pipe of 40 mm minimum outer dia in runway shoulder by cutting the existing concrete/bitumin (upto 75 mm width & 200 mm depth) by using appropriate tools like core cutting machine ,cutter, breaker, microtrenching machine as suited best to avoid any damge to runway/shoulder and making the same good using the suitable material like concrete/bitumin/polysulphide adhesive /sealant as applicable & approved by E.I.C, maintaining the same existing slope of the shoulder after laying of the HDPE pipe complete etc as required.
Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing precast earthing chamber with size of 450X450X300 mm made of concrete of M15 grade with suitable MS cover plate, loacking arrangment with one no of suitable hole to accommodate the 40mm dia. HDPE pipe , watering pipe with charcoal/ coke and salt etc. as required.
Providing and fixing 6 SWG dia G.l. wire on surface or in recess or on cable tray for loop earthing along with existing cable as required.
Providing and fixing 25 mm X 5 mm G.I. strip in 40 mm dia medium class G.I. pipe from earth electrode including connection with G.I. nut, bolt, spring, washer excavation and re-filling etc. as required.
Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required.
Providing and fixing of 400 A Change over switch along with Metal Enclosure and required bus bar to terminate the 400 Sq.mm cable as incomer (02 nos) and 400 Sq.mm Cable as outgoing complete as required.
Supply of 2KVA single phase 230V online UPS system alongwith in built Battery with 30 minute back up complete as required.
Supply and fixing of outdoor type PVC / metal feeder Pillar with stand suitable to house 01 no 2 kVA online UPS alongwith Battery and Supply & fixing of Suitable MCB and termination of cable of size 3x4 sq.mm cable at Apron area complete as required.
Providing 4 wheel Trolley mounted outdoor Mobile DG Set along with canopy of 25 KVA capacity complying the CPCB standards complete as required.
SITC of IP 65 , whether proof FRP type pole mounted PVC cable termination Junction box including 25sq mm 5 Nos. Terminal with 1 no 6A SP MCB & 2 Nos. Pole Mounting Clamp , suitable size 4 pole aluminium busbar to terminate 2 nos of 4 x 25 Sq. mm XLPE aluminum armoured cable (Loop in/ loop out cable) , suitable size MS clamps with nut bolts for fixing arrangement of junction box on pole complete as required.
Krishsons International Engineers And Consultants (I) Pvt. Ltd
Shiva Enterprises
Techno Electricals
DOSHI ELECTRIC ENGG. CO.
Ascent Electrification Engineers
Mayur Electric Works
Manish Electricals
Edge Telecom Pvt Ltd
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .