Annual Maintenance of ACs installed at Sonar Tari State Guest House Agartala Tripura for 2years
2022_CEPWD_28674_1
15_EE_DNIeT_MECH_DIV_AGT_22_23
Open Tender
Electrical Works
Item Rate
730 days
Sonar Tari State Guest House Agartala
Please refer Tender documents.
6 documents required · 6 mandatory
₹1,000
₹13,601
26 Aug 2022
23 May 2022
10 Jun 2022
23 May 2022
10 Jun 2022
23 May 2022
Amount
Complete servicing of AC machines (Indoor & outdoor Unit) as per direction of the Engineer-in-charge.
1.5/2.0 TR High wall split type AC
2.5/3.0 TR High wall Split and cassette AC
Leak testing of condenser & evaporator unit for performance and pressure testing etc and repair with brazing as per direction of the Engineer-in-charge.
1.5/2.0 High wall split type AC
2.5/3.0 TR High wall split and cassette type AC
Charging of fresh refrigerant gas (R-22) for 1.5/2.0/2.5/3.0 TR High wall split, and cassette AC system as per direction of the Engineer-in-charge.
Providing, fitting and fixing of hermetically sealed compressor for replacement of defective one as per direction of the Engineer-in-charge. (With one year warranty)
1.5 TR capacity High wall split type AC.
2.0 TR capacity High wall split type AC
2.5 TR capacity High wall split type AC
3.0 TR capacity High wall split and cassette type AC
Providing, fitting and fixing of hermetically sealed copper condenser unit for replacing old one as per direction of the Engineer-in-charge
1.5 TR capacity High wall split type AC
2.0/2.5 TR capacity High wall split type AC
3.0 TR capacity High wall split and cassette type AC
Fitting, fixing of blower motor of Ac systems after rewinding I/C necessary replacement of bush, shaft etc with complete varnishing as per direction of the Engineer-in-charge.
Repair/ replacement of defective scroll motor of indoor unit split type AC system as per direction of the Engineer-in-charge.
Repair/ replacement of defective swing motor of indoor unit split type AC system as per direction of the Engineer-in-charge
Repair/ replacement of defective relay of split type AC system as per direction of the Engineer-in-charge.
Replacement of air filter of split type AC system as per direction of the Engineer-in-charge
Repair/replacement of defective indoor PCB circuit as per direction of the Engineer-in-charge.
1.5/2.0/2.5/3.0 TR split type high wall AC
3.0 TR cassette type AC
Repair/ replacement of defective outdoor PCB circuit for cassette type AC system as per direction of the Engineer-in-charge
Repair/ replacement of defective PCB transformer for split type AC system as per direction of the Engineer-in-charge
Repair/ replacement of defective pump motor for cassette type AC system as per direction of the Engineer-in-charge
Supply and installation of additional length of copper pipe of 5/8” diameter and ¼” diameter for suction and liquid line with insulation and necessary wiring (with three pin electrical plug) to connect the indoor and outdoor unit as per direction of the Engineer-in-charge
Supply and installation of additional length of copper pipe of 5/8” diameter and 3/8’ diameter for suction and liquid line with insulation and necessary wiring (with three pin electrical plug) to connect the indoor and outdoor unit as per direction of the Engineer-in-charge
Fabrication of M.S platform for placement of condensing unit by using M.S angel of (50x50x5)mm/(65x65x5)mm size base plate, nuts & bolts/universal bracket (GSS) for ODU of split type AC system including all accessories for on-site installation i/c painting, fitting, fixing grouting by cement mixer as per direction of the Engineer-in-charge
Dismantling and re-installation of 1.0/1.2/1.5/2.0/2.5/3.0 TR split and cassette type AC system as per direction of the Engineer-in-charge
Providing, fitting and fixing of G.C.I shed of two parts slanting with ridge and necessary structure by using M/S angle of (30x30x5) mm size M.S flat (18x5) mm size over condensing unit i/c painting and finishing as per direction of the Engineer-in-charge
Providing hard/ coil PVC pipe of good quality of 25 mm diameter including necessary clamping and fitting for draining of condensate water from indoor unit as per direction of the Engineer-in-charge
Repair/ replacement of defective thermostat for split type AC system as per direction of the Engineer-in-charge
Repair/ replacement of defective 45 mfd capacitor for split type AC system as per direction of the Engineer-in-charge
Repair/ replacement of defective 50 mfd capacitor for split type AC system as per direction of the Engineer-in-charge
Repair/ replacement of defective terminal clip as per direction of the Engineer-in-charge
Providing fitting and fixing of PVC tape (Black tap) as per direction of the Engineer-in-charge
Repair/ replacement of defective capillaries/ dryer for split type AC system as per direction of the Engineer-in-charge
Supply and installation of additional length of electrical copper wire 4 mm size with casing size 01 (One) inch including other materials to connect outdoor unit with electrical panel as per direction of the Engineer-in-charge
Repair/ replacement of defective fan capacitor 2.0/2.5/4.0/5.0 mfd as per direction of the Engineer-in-charge
Repair/ replacement of defective fan blade of outdoor unit of split and cassette type AC system as per direction of the Engineer-in-charge
Repair/ replacement of defective connector for split type AC system as per direction of the Engineer-in-charge
Repair/ replacement of defective contactors for split type AC system as per direction of the Engineer-in-charge
Repair/ replacement of defective remote with battery for split and cassette type AC system as per direction of the Engineer-in-charge
Repair/ replacement of defective coil sensor for split type AC system as per direction of the Engineer-in-charge
Repair/ replacement of defective room sensor for split type AC system as per direction of the Engineer-in-charge
Repair/ replacement of defective nitral tape (Arrow tape) as per direction of the Engineer-in-charge
General checking of split/ cassette type AC system for functioning and repairing without replacement of spare parts
RS COOLING APPLIANCES
R.P.ELECTRONICS
stage.html
html • 0.04 MB
tech_eval.pdf
fin_eval.pdf
aoc.pdf
finance_29096.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .