Electrical Factory Maintenance Works at SEPF, Kasaragod for 2 years
26330
HAL/KGD/TS/E/NIT/2026-27/04
Open
Works
Accessories Complex - SEPF-KASARAGOD
₹0
₹1.3 L
11 Aug 2026
11 Aug 2026
11 Aug 2026
9 Sept 2026
Name of the Individual / Firm / Company: * Mandatory
Type of ownership
Details of Constitution or Legal Status such as certificate of incorporation, shops and establishments, Contractor registration No etc.,
Address for correspondence:
GST NO.:
PAN No.:
Contact details
Please Enter Contact person Name
Pls Enter Mobile No
Average annual financial turn over during the last 3 years, ending 31st March of 2023 financial year [ should not be less than 30% of Amount put to tender]. Turnover for 3 years are compulsory.
TURN OVER IN Rupees
Enclosed
Enclosed
Enclosed
ESI & PF Nos with proof (If any)
Related Document to be Uploaded in e-Procurement Portal
Bank(s) details: [Copy of the cheque leaf to be uploaded]
Related Document to be Uploaded to eProcurement Portal (Note Canceled cheque leaf to be uploaded)
Latest Bankers Solvency Certificate from Nationalized/ scheduled Bank issued NOT before 12 months from the date of Tender submission.
Pls Enter Details to 'Name of the Bank' , 'Date of Issue','Value Rs in lakhs
Experience of having successfully completed similar works during last 7 years ending last day of month previous to the one in which applications are invited. [Latest work experience certificate may be uploaded] (i) THREE similar completed works each costing not less than the amount equal to 40% of the estimated cost. (ii) TWO similar completed works each costing not less than the amount equal to 50% of the estimated cost. (iii) ONE similar completed work each costing not less than the amount equal to 80% of Amount put to the tender.
40% (Three Works)
Type of Work: [ Incase of private works the same shall be supported with TDS certificate]
Please enter Details for Work No 1
Type of Work: [ Incase of private works the same shall be supported with TDS certificate]
Pls Enter Details for Work No II
Type of Work: [ Incase of private works the same shall be supported with TDS certificate]
Pls Enter Details for Work No III
Details of person holding the power of Attorney (If different from contact person)
Related Document to be Uploaded to eProcurement Portal
Pls Enter Details for Person holding Power of Attorney
DECLARATION I
Pls Accept The Delarication
Valid HT/LT Electrical Contractor License of appropriate voltage issued by any State Government under clause 45 of Indian Electricity Rules 1956.
DECLARATION II
Pls Accept the Delaration II
Specification of item
Supply, Repair, Replacement, Testing and Fine tuning ofthe APFC panel with below mentioned components as per scope of work and terms and conditions (B)
Capacitor Duty Contactor 240V COIL, 50/60Hz (NO AUX.) suitable for 3 kvar Capacitor
3.3 kVAr Super HD Cyl Capacitor 480V, 50hz
3 kVAR 7% AL Reactor, 40V, 50 Hz
HRC FUSE 10 Amps Suitable for Existing SFU.
Capacitor Duty Contactor 240V COIL, 50/60Hz (NO AUX.) suitable for 5 kvar Capacitor
5 kVAR-BX/CYL ULT HEAVY CAP, 480V , 3 Ph
5 kVAR 7% AL Reactor, 440V, 50hz
HRC FUSE 16Amps Suitable for Existing SFU.
Capacitor Duty Contactor 240V COIL, 50/60Hz (NO AUX.) suitable for 10 kvar Capacitor
10 kVAR-BX/CYL ULTRA HEAVY CAP, 480V , 3 Ph
10 kVAR 7% AL Reactor, 440V, 50hz
HRC FUSE 32Amps Suitable for Existing SFU.
Capacitor Duty Contactor 240V COIL, 50/60Hz (NO AUX.) suitable for 15 kvar Capacitor
15.1 kVAR BX/CYL ULTRA HEAVY CAP, 480V , 3 Ph
15 kVAR 7% AL Reactor, 440V, 50hz
HRC FUSE 40Amps Suitable for Existing SFU.
Capacitor Duty Contactor 240V COIL, 50/60Hz (NO AUX.) suitable for 25 kvar Capacitor
25 kVAR-BX/CYL ULTRA HEAVY CAP, 480V , 3 Ph
25 kVAR 7% AL Reactor, 440V, 50hz
HRC FUSE 63Amps Suitable for Existing SFU.
MCB TP 63A
MCB SP 6A
16 stage or higher APFC controller
8 inch panel exhaust Fan with MCBs and steel brackets
Push button for switching On & Off the capacitor banks
Auto Manual Switch
1.5 sqmm multistrand flexible copper cable for control circuit
4.0 sqmm multistrand flexible copper cable for power circuit
6.0 sqmm multistrand flexible copper cable for power circuit
10.0 sqmm multistrand flexible copper cable for power circuit
16.0 sqmm multistrand flexible copper cable for power circuit
Rupees Two Only
Thirty Six Paise Only
Rupees Two and Thirty Six Paise Only
Rupees Two and Thirty Six Paise Only
Scope of work and terms and conditions
LK/ABB/Schnieder/Siemens/Havells
LK/ABB/Schnieder/Siemens
LK/ABB/Schnieder/Siemens
LK/ABB/Schnieder/Siemens/Havells
LK/ABB/Schnieder/Siemens/Havells
Finloex/Polycab/RRKabel/Havells
Rexnord or reputed brand
L&T-Esbee/Technic/ABB
Salzer/Kaycee/ABB
Specification of item
Supply and wiring of circuit/submain with 2 runs of 1.5 sq mm and 1 run of 1.5 sq mm (Earthing looping Point) FRLS PVC insulated 1.1Kv grade flexible copper multi stranded conductor/wire in a suitable PVC conduits with bends, couplers and all fixing accessories on the surface/recessed of wall with all inter connection complete viz: lugs etc Make :Finolex/Polycab/Havells/Vguard/RR Kable/APAR
Repair and Replacement of Faulty/aged 11K feeder installations by SITC of new HT installation which includes, DO fuses, Lightning arrrestors, Inulators ,Conductor Jumpers etc at HAL approx 700 mts, 11KV Over Head line including DP structures (3 Nos) as required and site requirement.
Supply, installation and testing of new set of three piece nonlinear resistor type lightning arrestor (porcelain/polymer suitable for 3 wire, 11 KV overhead lines with rated voltage 9 KV (rms) with a nominal discharge current rating of 5 KA and complete with galvanised clamping arrangement, G.I. bolts, nuts, washers etc.by replacing faulty/unserviceable 11KV lightning arrrestor as per site requirement .
Supply, installation and testing of new set 11 KV pin insulator (porcelain/polymer ) complete with large steel head G.I. pin, nuts, washers etc..by replacing faulty/flashed 11 KV pin insulator as per site requirement .
Supply, installation and testing of new set 11 KV disc insulator (porcelain/polymer) for 11 KV over head lines with set of galvanised insulator fittings, ball and socket type and complete with galvanised strain clamps, bolts, nuts, washers etc.by replacing faulty/flashed 11KV disc insulators as per site requirement .
Supplying and erecting new set of galvanised stay set for 11 KV over head lines complete with 19/ 20 mm dia X 1.8 metres long stay rod, anchor plate of size 45 cm X 45 cm X 7.5 mm thick, thimble, stay clamps, turn buckle ( 20 mm X 600 mm ), 7/ 4.00 mm dia G.I. stay wire and 11 KV strain insulator etc in cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size ) foundation including excavation and refilling etc. Replacement of corroded/aged galvanised stay set to be ensured as per site rquirement.
Supplying and erection of two lengths of channel iron 75 mm X 40 mm X 6 mm (7.14 kg per metre) of 4.5 Mtr double pole cross arm for three wire 11KV over head line conductors complete with through bolts and nuts for clamping to the poles, 50 mm X 6 mm M.S. flats welded on one side to the channel iron and with bolts and nuts on the other side for tying the cross arms together, including drilling holes for insulator pins/ fittings, bolts, nuts and washers etc (as per drawing) and painting with primer and finish paint as required.
Supplying and erection by replacement of rusted channel iron 75 mm X 40 mm X 6 mm (7.14 kg per metre) V shape cross arm approx 1 mtr for two 11 KV over head line conductors complete with 50 mm X 6mm M.S. flat iron clamps, bolts and nuts including drilling holes for insulator pins, bolts, nuts and washers etc (as per drawing) and painting with primer and finish paint as required.
Supplying and installation of 11KV, 25A rated Drop out fuses by replacement with new fuse element of flashed Drop out fuse in DP structures complete with binding to terminal ensuring connection as required and site requirements enuring all safety requirements in coordination with KSEB.
Supply and Providing M.V.Caution and danger notice plate of 200 mm × 150 mm, made of mild steel, at least 2 mm thick and vitreous enameled white on both sides, and with inscription in single red colour on front side as required.
Replace aged rusted 11kV Gang Operated (GO) Air Break (AB) switch by Supply and installation testing of of 11kV Gang Operated (GO) Air Break (AB) triple pole Switches out door type with porcelain/polymer insulators, hot-dip galvanized steel, tinned copper contacts, arcing horns, Hot-dip galvanized ferrous parts, tinned copper current paths, copper alloy contacts, copper braided jumpers and operation via a ground-level handle of `B' Class G.I. Operating pipe of 32 mm outer diameter and 6 meter length in single piece without joint. The mechanism should give good mechanical leverage with minimum of loose/lost motion. There should be provision for pad-locking in both `on' and `off' position, with locking mechanism and for performance should withstand voltages (dry/wet 28kV (Power Frequency, Earth/Poles), 32kV (Across Terminals), 75kV (Impulse).) and short-circuit tests, with critical requirement like contact pressure, creepage distance etc conforming to IS:9921
Replace aged rusted DO expulsion type fuse units of 11KV/12KV rating of type Porcelain/polymer in existing DP structures by supply and installation of 11 KV D. O. Fuse Elements Suitable For Dropout Fuse Unit Complete with 8.5 Inch Long Tube And Tin Coated/Copper Trail Length Of Fuse Element Of Rating 100A. DO fuse with set of three should include single pole with insulators mounted on GI channel barrel and suitable rating of fuse element as per site requirement complete. DO fuse set should with stand lightning impulse voltage of 75kV (peak) to earth and 85kV (peak) across the isolating distance. Material should confirm to silver-plated brass contacts, hot-dip galvanized ferrous parts for corrosion resistance, and compliance with standards IS:9385
Supplying and erection of channel iron 75 mm X 40 mm X 6 mm (7.14 kg per metre) of 25 cm pole top bracket/ cross arm for single 11 KV over head line conductor complete with 50 mm X 6mm flat iron clamp, bolts, nuts and washers including drilling holes for insulator pins, bolts and nuts etc and painting with primer and finish paint as required.
PREVENTIVE MAINTENANCE OF Substation including LT, APFC, Main Lighting, 11KV HT panels, 11/0.440 KV, 500KVA distribution transformer, Pump House as per Annexure 2
Preventive Maintenance of LT, APFC and Main Lighting panels Preventive maintenance of LT Electric distribution, PF and main lighting panels of 3-pole/4-pole, 415V ACB's (ABB Make) of all amperage capacities, digital and analog meters including serviceability and calibration, switches, MCCB, MCB, isolator etc list as per Annexure-2B and as per check list.
Preventive Maintenance of 11/0.440 KV, 500KVA distribution transformer : Preventive Maintenance of outdoor 11/0.440 KV, 500KVA Distribution transformer with OLTC as per Annexure-2C and as per check list.
Preventive maintenance of Pump House motors (Fire & Overhead) and its control panel consisting of starters, switches, contactors relays etc including Jockey pump as per Annexure-2D Yearly.
500KA Transformer Overhaul, Oil filteration & BDV testing: Overhauling and Testing of existing 500KVA transformers for oil filteration and BDV testing to improve the dielectric strength of the oil with high vacuum filter machine with calibrated equipment and test certificates submitted to EIC.
Oil leakage arresting and complete overhaul and servicing of transformer as per Annexure-3A
Additional transformer oil for topping up & filtration losses as per requirement
Filteration of oil and BDV test and as per Annexure-3B
Replacement of faulty CT-PT and TOD meter installed for check metering by supplying and erection of new CT-PT and ToD meter in existing DP structure near to 11KV substation
Supply installation and integration of Outdoor combined CT- PT Detailed Specification as per Annexure-4A
Supply installation and integration ofToD meter Detailed Specification as per Annexure-4B
Supply installation and integration of Metallic metering Box for mounting ToD meter Detailed Specification as per Annexure-4C
Installation and testing Specification as per Annexure-4D
Supplying and fixing 30 A, 415 V TPN Industrial type socket outlet, with 4 pole and earth, metal enclosed plug top along with 32 A "C" curve, TPN MCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket outlet and complete with connections, testing and commissioning etc. as per site requirement (Make:C&S,Indo Asian,Havells,Legrand,L&K)
Supplying and fixing 63 A, 415 V TPN Industrial type socket outlet, with 4 pole and earth, metal enclosed plug top along with 63 A "C" curve, TPNMCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc.as per site requirement. (Make:C&S,Indo Asian,Havells,Legrand,L&K)
Supplying and fixing 125A, 415 V TPN Industrial type socket outlet, with 4 pole and 125A 4 pole MCCB in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. as per site requirement. (Make:C&S,Indo Asian,Havells,Legrand,L&K)
Supplying and fixing 20 A, 240 V, SPN Industrial type socket outlet, with 2 pole and earth, metal enclosed plug top along with 20 A "C" curve, SP, MCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. as required.(Make:C&S ,Indo Asian, Havells, Legrand, L&K)
Supplying & fixing suitable size GI/plastic box wih modular plate and cover in front on surface or in recess including providing and fixing 25 A modular 3 pin socket outlet and 25 A modular SP MCB, "C" curve including connections, painting etc. as requiredMake:Legrand/Crabtree/Schneider/Havells/L&K/MK
Supplying and fixing 20 A, 415 V TPN Industrial type socket outlet, with 4 pole and earth, metal enclosed plug top along with 20 A "C" curve, TP MCB, in water proof sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. as per site requirement. (Make:C&S ,Indo Asian, Havells, Legrand, L&K)
Wiring for light point/ fan point/ exhaust fan pointt with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable etc.as per site requirement. Make:Finolex / Havells / Vguard /RR Kabel/Polycab/APAR
Daily Electrical Operation and Regular routine Maintenance of entire HAL SEPF factory including 11/0.415KV Substation operations in round the clock mode (24 Hours) along with approx 700 mts, 11KV Over Head feeder system ensuring reliable and healthy serviciability as per Annexure -1, Scope of work for Substation Operation & Factory maintenance by asigning experienced / qualified supervisor cum substation operators for the complete contract period of 2 years All works carried out on daily basis for eight hours will be considered as one job.
Supply and wiring of circuit/submain with 2x2.5 sq mm and 1 run of 1.5 sq mm (Earthing looping Point) FRLS PVC insulated 1.1Kv grade flexible copper multi stranded conductor/wire in a suitable PVC conduits with bends, couplers and all fixing accessories on the surface/recessed of wall with all inter connection complete viz: lugs etc. Make : Finolex/Polycab/Havells/Vguard/RR Kable/APAR
Supply and wiring of circuit/submain with 2x4 sq mm and 1 run of 4 sq mm (Earthing looping Point) FRLS PVC insulated 1.1Kv grade flexible copper multi stranded conductor/wire in a suitable PVC conduits with bends, couplers and all fixing accessories on the surface/recessed on wall with all inter connection complete viz: lugs etc. Make : Finolex/Polycab/Havells/Vguard/RR Kable/APAR
Rewinding, repair, and reconditioning of the Single phase 30-90 watts motors on copper retention basis with class 'F' insulation by using polyester super enamelled copper (Make Shramic/ apple), with necessary sleeves, providing of varnish coating,reconditioning of shaft are necessary as per Guidance of EIC
Dismantling of Exhaust/ceiling fan and painting the same with one or more coats of spray painting with synthetic enamel paint of approved brand after application of suitable primer to give an even shade, including cleaning of surface with detergent and replacing the damaged rubber reel, nuts and bolts with washers and safety pins, reinstalling the same as required
Replacement of faulty beyond economical repair ceiling fan with BLDC Fan of 1200mm sweep, BEE 5 star rating, service value ≥ 6.0 CM/Min/Watt, air delivery 210 CM/Min (Minimum)with remote by Supply, Installation, Testing and Commissioning of ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. metal(Aluminium alloy) blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, steel/Al body. Power Factor not less than 0.9, Service Value (CM/M/W) minimum as below, 350 RPM (tolerance as per IS : 374-2019), THD (Total Harmonic Distortion) less than 10%, remote (preferably mobile app based) for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 °C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC supply Ceiling Fan compliant to IS 374:2019 fan i/c external connections with 1.5 sq.mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required.
Supplying and fixing of following sizes of medium class PVC conduit along with all accessories, bends, junctions, saddles etc in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. Make : PrecissionHycon/Evershine/Surya
Providing and fixing following rating and breaking capacity and pole MCCB with thermo magnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, Ics=100% Icu and Operational Voltage 690V etc. as required.(ABB/L&K./Legrand/Schnieder/C&S/Havells)
100 A, 16 KA,TP MCCB
125 A, 16 KA,TP MCCB
Supply and installation of ready to use 240V Single phase 16 Way MCB Distribution Boxes with single/double IP43 metal door, surface/recess mountable Type. MCDB is to be with modular incomer, provided with insulated vertical phase bus-bars 32A, neutral bar/s with shroud/s, earth bar/s, sticking saddles, cement spill protector, color-coded interconnecting wire set, cable ties, blanking plates and circuit identification labels. Made from CRCA sheet steel and powder coated. With provision for double pole MCB as incomer and SP MCBs as outgoings. Should conform to IS 8623-1 & 3, IEC 61439-1 & 3. The DB shall be populated with SP, C curve MCB as outgoing and Incomer of DP MCB along with DP RCCB. The activity involves installation of DB, routing of cable from the desired location to the DB MCB, interconnection and complete termination of cables in the DB.
Replacing rusted /faulty 3 phase DB by Supply and installation of ready to use single/double door DBs surface mountable - 8 way vertical TPN with modular incomer and IP43 metal door. Provided with insulated vertical phase bus-bars 125A, neutral bar/s with shroud/s, earth bar/s, sticking saddles, cement spill protector, color-coded interconnecting wire set, cable ties, blanking plates and circuit identification labels. Made from CRCA sheet steel and RAL 9003, powder coated. With provision for 4 pole 32 A MCB as incomer along with 32A RCCB and SP/TP MCBs as outgoings. Should conform to IS 8623-1 & 3, IEC 61439-1 & 3. The DB shall be populated with 10A SP MCB - 5 nos, 16A - 4 Nosand 32A TP MCB - 5 Nos The activity involves installation of DB, routing of cable from the desired location to the DB MCB and complete termination of cables in the DB. Make: L&T/Legrand/ABB/Schneider
Replacement of faulty (BER) four pole electrically operated draw out type Air Circuit Breaker by Supply, retrofitting, testing & commissioning of new 800A, 50 kA four pole electrically operated draw out type Air Circuit Breaker, release with LSIG protection, communication and power metering module with required accessories and retrofit kit made out of aluminium bus bar and hardware as required as per specification at Annexure - 9 Make: L&K/ ABB/C&S/Schneider/Siemens
Replace faulty MCB by Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required and site requirement Make: L&T/Legrand/ABB/Schneider
Single pole
Single pole and neutral
Double pole
Triple pole
Triple pole and neutral
Supplying and fixing following rating, double pole, (1 phase and neutral), residual current circuit breaker (RCCB) 25A , having a sensitivity current 100 mA in the existing MCB DB and A&T testing tables complete with connections, testing and commissioning etc. as required.Make: L&T/Legrand/ABB/Schneider
Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB) of 40A , having a sensitivity current 100 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required.Make: L&T/Legrand/ABB/Schneider
Supplying and fixing following rating, four pole, 415 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required. Make: L&T/Legrand/ABB/Schneider
40 A Each
63 A Each
100 A Each
Providing and fixing 25 mm X 5 mm copper strip on surface or in recess for connections etc. as required with insulator and complete interconnection in all respects as per site requirement.
Providing and fixing 25 mm X 5 mm G.I. strip on surface with insulator supports or in recess for connections etc. and complete interconnection in all respects as per site requirement.
Supplying and fixing following modular switch, socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. Make:Legrand/Crabtree/Schneider/Havells/L&K/MK
5/6 A switch
2 way 5/6 A switch
15/16 A switch
3 pin 5/6 A socket outlet
6 pin 15/16 A socket outlet
Telephone socket outlet RJ-11
RJ-45 LAN socket outlet
Supplying and fixing following Modular base & cover plate on existing modular metal boxes/plastic boxes etc required.Make:Legrand/Crabtree/Schneider/Havells/L&K/MK
1 or 2 Module (75mmX75mm)
3 Module (100mmX75mm)
6 Module (200mmX75mm)
8 Module (125mmX125mm)
Supplying and fixing following size/ modules, GI/Plastic box in surface/recessed along with modular base & cover plate for modular switches in recess etc. as required. Make:Legrand/Crabtree/Schneider/Havells/L&K/MK
1 or 2 Module (75mmX75mm)
3 Module (100mmX75mm)
6 Module (200mmX75mm)
8 Module (125mmX125mm)
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 A modular socket outlet and 5/6 A modular switch, connections etc. as required. Make:Legrand/Crabtree/Schneider/Havells/L&K/MK
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess,including providing and fixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required. Make:Legrand/Crabtree/Schneider/Havells/L&K/MK
Supply and replacement of faulty RJ-11 by fixing new modular telephone outlets RJ-11 socket in recessed/surface common PVC/MS box with modular plastic cover with cable end interconnection/terminations complete of the outlet. Make : Lucent/Dlink/Belkin/Legrand/Tyco/Tplink
Supply and replacement of faulty/damaged modular RJ-45 socket and installation in new common PVC/MS box in recess/surface with modular plastic cover with cable end interconnection/terminations complete of the outlet. Make : Lucent/Dlink/Belkin/Legrand/Tyco/Tplink
Repair & Replacement of faulty street light lamps in 9 Mtr single pole Single arm/ 2 arm street light (2 lights) using labour and safety ladders as per site conditions and instructions of EIC. Serviceable street lights will be provided by HAL for replacement
Supplying, drawing, Installation, Testing and commissioning of CAT6 UTP LSZH 23AWG TwistedPair Cable in existing conduit/ on surface, Category 6 Unshielded Twisted Pair, 4 pair should be complied as per UL/ETL verification program for compliance with ANSI/TIA-568.2-D standard. Outer diameter should be in the range of 6.1mm nominal with Operating Temperature Range : -5° to +60°C, Bending Radius : < 4 X Cable Diameter at –5°C ± 1°C and Pulling Force: 11.5Kg etc. complete as required. Make : Dlink/Polycab/Tyco/Honeywell /Molex
Installation, Testing, Commissioning of wall bracket /ceiling fittings of all sizes and shapes containing upto two GLS/CFL/LED lamps per fitting, complete with all accessories including connections etc. as required
Supplying and drawing following pair 0.5 mm dia FRLS/HFFR PVC insulated annealed copper conductor, unarmored telephone cable in the existing surface/ recessed steel/ PVC conduit as required. Make : Dlink/Finolex/
Replace faulty/flickering 40 W LED Panel light with supplying of LED panel lights 2X2 feet (System lumen efficacy ≥120 <135 lm/Watt) Recessed/ (square/ Rectangular) SMD type of following body material with PMMA and prismatic diffuser Powder coated die cast /Extruded aluminium Body including trim with Aluminium Reflector and Specification and installation as per Annexure-7A. Make: Bajaj/Philips/Havells/Wipro/Luker/Syska/Crompton
Replace faulty LED Flood Light in existing building and High mast , by Supplying, installation, Testing & Commissioning of powder coated pressure die cast aluminium (System lumen efficacy ≥120 and <135 lm/Watt). Supplying, Installation, Testing & Commissioning of Flood Light, powder coated pressure die cast aluminium body with built in or separate driver as per the requirement with Driver efficiency >85%, Input voltage: Input voltage: 140-270 Volt AC, frequency 50/60 hz, , (Specification as per Annexure-7D) Make : Bajaj/Philips/Havells/Wipro/Luker/Syska/Crompton
Replacement of faulty/flickering LED street lights and building lights by Supplying, installation, Testing & Commissioning of new luminaries.installation involves ensuring saffety tools ladders all required for replacement and installation of new LED lghts.as per Annexure-7 Bajaj/Philips/Havells/Wipro/Luker/Syska/Crompton
Replace faulty/flickering 90 watt LED street lights by Supplying, installation, Testing & Commissioning of Street light LED fixture powder coated pressure die cast aluminium body with driver as per the requirement with Driver efficiency >85% and (System lumen efficacy ≥120 <135 lm/Watt), Input voltage: 140-270 Volt AC, frequency 50/60 hz, (Specification as per Annexure-7C) Bajaj/Philips/Havells/Wipro/Luker/Syska/Crompton
Replace faulty building area lights by Supplying, installation, Testing & Commissioning of 100W LED fixture light with powder coated pressure die cast aluminium body with driver as per the requirement with Driver efficiency >85% and (System lumen efficacy ≥120 <135 lm/Watt), Input voltage: 140-270 Volt AC, frequency 50/60 hz, (Specification as per Annexure-7C) Bajaj/Philips/Havells/Wipro/Luker/Syska/Crompton
Renewal of CEA approval from Central Electricity Authority (Inspectorial), Govt.of India, for SEPF,Kasaragode, Main Substation (11/0.415KV/) with 500KVA Transformers 2 Nos ,400KVA DG set 1 Nos 1 Nos of RMU 11KV Indoor and Outdoor Breaker each. Accord and obtain approval for Periodical Inspection for meeting requirements as per regulation for 2 Years of CEA in Liasioning with Central Electricity Authority (Inspectorial), Govt.of India, Periodical Inspection, Renewal of Licence of CEA and approval for substations of 11KV at SEPF,Kasaragod to be carried out as per Annexure-5
Replacement of existing Faulty RYB LED indicating lamps in existing LT panel & PCC with new. Set of RYB (3 Nos) to be supplied inttegrated and tested in the existing panel feeders. Compact integrated Led indicator is to be of 240V 50/60 Hz Make: ELMEASURE/SIEMENS/L&K
Supply and replacement of faulty exhaust fans including installing and testing. Exhaust fans should be having aerodynamically contoured blade with maximum air load with minimum consumption continously rated heavy duty motor with pressure die cast aluminium rotor on two ball bearings. Rigid frame with rubber mounting for silent operation dust and water protection of IP55, epoxy powder coated for better pretreared corrosion resistant.Installation, Testing and Commissioning of exhaust fan in the existing opening, including making good the damage, connection, testing, commissioning etc. as required.
250 mm Ventillation Exhaust domestic FAN .Supply of 250 mm Ventillation Exhaust domestic FAN of 35-40 Watts domestic type with a free air delivery of minimum 800 CMH AND minimum 1250 RPM,35watt noise level below 55DB Make:USHA/Bajaj/Havells/Crompton/Orient/Khaitan/Almonard
300 mm Exhaust Fans of Heavy duty type Supply of 450 mm Exhaust Fans of Heavy duty type with a free air delivery of minimum 1135 CMH and minimum 1350 RPM and 50Watt and noise level below 55DB. Make:USHA/Bajaj/Havells/Crompton/Orient/Khaitan/Almonard
450 mm Exhaust Fans of Heavy duty type .Supply of Replacement of faulty 450 mm Exhaust Fans of Heavy duty type with a free air delivery of minimum 1135 CMH and minimum 940 RPM,6 pole, 140-Watt and noise level below 64 DB t Make:USHA/Bajaj/Havells/Crompton/Orient/Khaitan/Almonard
600 mm Exhaust Fans of Heavy duty type .Supply of Replacement of faulty 600 mm Exhaust Fans of Heavy duty type with a free air delivery of minimum 6000 CMH and minimum 700 RPM,6 pole, 240-200 Watt and noise level below 64 DB
Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required.
Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc.direct in ground (75 cm below ground level) including road cutting and filling if require as per site requirement
90 mm dia (OD-90 mm & ID-76 mm nominal)
120 mm dia (OD-120 mm & ID-103 mm nominal)
Supply & laying of PVC insulated aluminium conductor armoured cable of 1100V grade under ground by excavating upto a depth of 300mm and covering the cable with sand and brick cover/HDPE pipe and then restore the soil/concrete/ground to the original condition and then suppling all required fixing accessories like saddles, glands, lugs etc with complete cable end terminations as per site condition and as directed by the EIC. The laying of cable may involve cutting of concrete road for crossing over which also needs to be considered. Route markers also need to be placed along the cable path at a distance of 10 mts minimum. Make : Finolex/Polycab/Havells/Vguard/RR Kable.
10 sqmm 4 Core
25 sqm, 3.5 Core
Supply & laying of of 3.5/4C PVC insulated aluminium conductor armoured cable of 1100V grade in existing wall surface and cable trays suppling all required fixing accessories like clamps ,saddles, glands, lugs etc with complete cable end terminations as per site condition and as directed by the EIC. Make : Finolex/Polycab/Havells/Vguard/RR Kable.
3.5Core 35 sqmm
4Core 16 sqm
Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required.
Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required.
Supply and fixing 3 pin 5A ceiling rose including connections as required.
Supplying and fixing brass batten/ angle holder including connection etc. as required.
Replace existing faulty 18W LED - PL light lamp in LED Panel lights with new 18W LED - PL light lamp of 4 pin type insertion type having maximum 15.75 inch length with high efficient Diffuser and long life of 50,000 Hrs and cool temperature of 65000K. Make : Bajaj/Philips/Havells/Wipro/Luker/Syska/Crompton or any equivalent
Measurement, Maintenance and Revamping of Earth pits and Earthing system as per Annexure 6
Resistance measurement of earth pit twice a year as per Annexure-6A
Repair, maintenenace and resistance measurement of earth pit as per Annexure - 6B
Identification and labeling of earth pits as per Annexure - 6C
Providing maintenance free earthing system as per Annexure - 6D with a) Low carbon steel rod of 3000mm length and 20mm dia. b) Mineral compound 10kg or more as required c) Inspection chamber 450x450x300 mm (WxBxH)
Providing, Extension and revamping lightening arrestor systems over existing building as per the specifications Annexure-8
Providing and fixing 1 meter air terminal with accessories as per Annexure - 8a Make: Ashlok/Cape Electric/OBO/DEHN
Providing and fixing 3 meter air terminal with accessories as per Annexure - 8b Make: Ashlok/Cape Electric/OBO/DEHN
Supply and fixing of 8mm diameter solid aluminium round conductor as per Annexure - 8c Make: Ashlok/Cape Electric/OBO/DEHN
Supply and fixing of polyamide conductor holder 30mm with suitable stainless steel screws for fastening the conductor. Tested for weather and temperature resistant from -35 to +90 degree celsius. Make: Ashlok/Cape Electric/OBO/DEHN
Supply and fixing of stainless steel clamping clip with suitable stainless steel screw to fasten the conductor. Tested for weather and temperature resistant from -35 to +90 degree celsius. Make: Ashlok/Cape Electric/OBO/DEHN
Supply and fixing of cross connector/T connector/ quick connectors as applicable to route vertical down conductor /mesh formation made of hot dipped galvanised iron with necessary stainless steel screws, bolts and nuts as applicable. All materials used shall be corrosion free/resistant. Make: Ashlok/Cape Electric/OBO/DEHN
Providing and fixing equipotential bonding rail for lightning arrestor applications (Test Joint) as per Annexure - 8d Make: Ashlok/Cape Electric/OBO/DEHN
Supply & Installation of Three Phase Pluggable type surge arrestor for installtion at Sub Panel Level and PCC panel at individual buildings as per Annexure - 8e
Replacement of the damaged earthpit inspection chamber with new Earth system with Polypropylene & Polyethylene (UFE) earth electrode inspection chamber with heavy duty cover to cover the earth rod and should have a weight bearing capacity of 50KN.Annexure - 8f Make: Ashlok/Cape electric/OBO/Dehn
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
raw.json
RAW_JSON
NOTICEINVITINGTENDERElectricalmaint2026to28.pdf
TENDER_DOCUMENT • 0.14 MB
SUBSTATIONMAINTENDERDOCS.pdf
TENDER_DOCUMENT • 1.86 MB
spec.pdf
TENDER_DOCUMENT • 0.14 MB
AnnexureLElectricalmaint2026to28.pdf
TENDER_DOCUMENT • 0.01 MB
5PQElectricalmaint2026TO28.xlsm
TENDER_DOCUMENT • 0.02 MB
EMPricebidElectricalmaint2026TO28.xlsm
TENDER_DOCUMENT • 0.06 MB
proformaBElectricalmaint2026to28.pdf
TENDER_DOCUMENT • 0.01 MB
coveringletterforEMDthroughSBIcollect.pdf
TENDER_DOCUMENT • 0.01 MB
eftblankElectricalmaint2026to28.pdf
TENDER_DOCUMENT • 0.01 MB
proformaAElectricalmaint2026to28.pdf
TENDER_DOCUMENT • 0.01 MB
AnnexureSElectricalmaint2026to28.pdf
TENDER_DOCUMENT • 0.01 MB
AnnexureIICElectricalmaint2026to28.pdf
TENDER_DOCUMENT • 0.01 MB
AnnexureIElectricalmaint2026to28.pdf
TENDER_DOCUMENT • 0.01 MB
schedule.pdf
TENDER_DOCUMENT • 0.09 MB
AnnexureIIBElectricalmaint2026to28.pdf
TENDER_DOCUMENT • 0.01 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at [email protected].