Loading…
Loading…
Tender ID
Tender Value
₹2.0 Cr
EMD Value
₹4.1 L
Closing Date
9 Mar 2026, 4:30 pmClosed
Executive Engineer, building project department, Vadodara Municipal Corporation
Construction of district library in (Bapod) East Zone area of VMC ( Fourth Trial)
281218
PRO No.1228/25-26, Building Project
Open
Miscellaneous Works
Works
Vadodara
5 documents required · 5 mandatory
₹10,000
Municipal commissioner ,Vadodara municipal corporation
₹4.1 L
26 Feb 2026
26 Feb 2026
26 Feb 2026
9 Mar 2026
26 Feb 2026
NAME OF WORK : NEW CONSTRUCTION WORK Of DIST. LIBRARY AT EAST ZONE , VADODARA FOR VADODARA
SCHEDUAL B SHEET
NO. DESCRIPTION QTY UNIT RATE. AMOUNT
Excavation for foundation upto 1.5 mt including sorting out and stacking of
useful materials and dewatering, disposing of the excavated stuff from 0 to
1 50mt within VMC Limit. (A) Loose or soft soil 1568 Cum 120
Excavation for foundation for depth from 1.5 m to 3.0 m
including sorting out and stacking of useful materials and
disposing off the excavated stuff upto 50 Meter lead.(B)
2 Dense or Hard soil 792 Cum 166
Filling in foundation and plinth with murrum or selected good soil (from
outside) in layers of 20 cm thickness including watering, ramming and
3 consolidating etc. completed.(upto 10 ton) 246 Cum 296
Filling with available excavated earth (excluding rock) in trenches, plinth,
sides of foundations etc. in layers not exceeding 20 cm, in depth
4 consolidating each disposited layer by ramming and watering. 1684 Cum 134
Filling in plinth with sand under floors including watering ramming,
5 consolidating and dressing complete 72 Cum 472
Providing and laying rubble for appron (each stone weighting not less than
40Kg.) including and packing and filling in the interestices with quarry-
6 spalls. 309 Cum. 1067
Carrying out plinth treatment to post construction / existing structure by
spraying chemical solution for termite control treatment including labour
and material consistent with I.S.I specification. (Plinth Area will be
7 measured for payment purpose) 750 Sqmt. 97
Add extra for Disposing off the excavated stuff of above items for lead
8 of 0.5 k.m. to 3 k.m 277 Cum 129
Providing and laying cement concrete 1:3:6 ((1 cement :3 coarse sand:
hand broken stone aggregates 40 mm nominal size) and curing complete
9 excluding the cost of formwork in foundation and plinth( more than 10 ton) 83 Cum 3081
Providing and laying cement concrete 1:4:8 (1- Cement : 4- coarse sand : 8-
hand broken stone aggregates 40 mm nominal size) and curing complete
10 excluding cost of formwork in foundation and plinth 28.1 Cum 2747
Providing and laying controlled cement conceret M250 (Considering
minimum cement content 360 Kg/Cumt.) and curing complete excluding
the cost of formwork, centering, shuttering, Scaffolding, stuting and
propping etc. in shape and size and removal of the same etc. complete at
all levels as directed by EIC.
Foundation, Footing, base of column and Mass Concrete (more than
11 tone ) 294 Cmt. 4248
Providing and laying controlled cement conceret M250 (Considering
minimum cement content 360 Kg/Cumt.) and curing complete excluding
the cost of formwork and reinforcemnet for reinforced concrete work in: as
directed by EIC.
12 Columns, Pillars posts and struts(more than 10 tone ) 64 Cmt. 4628
Providing and laying controlled cement conceret M250 (Considering
minimum cement content 360 Kg/Cumt.) and curing complete ,excluding
the cost of formwork and reinforcemnet for reinforced concrete work in: as
directed by EIC.
13 Tie Beams, Girders and cantilever at ground level(more than 10 tone ) 153 Cmt. 4527
Providing and laying in position Ready Mixed M-300 grade
concrete for reinforced cement conctere work , using cement
content as per approved Design Mix manufactured in fully
automatic batching plant and transported to site of work in
transit mixer for a lead up to 10 kms having continuous
agitated mixer, manufactured as per mix design of specified
grade for reinforced cement concrete work including pumping
of R.M.C. from transit mixer to site of laying, excluding the
cost of centering shuttering finishing and reinforcement
including cost of admixtures in recommended proportions as
per IS: 9103 to accelerate/ retard setting of concrete, improve
workability without impairing strength and durability as per
direction of the Engineer - in - charge. Without Fly Ash (Min
cement level as per latest IS 456 shall be maintained)
14 (Cement level 475 kg ) 63.45 Cmt. 5093
Providing and laying controlled cement conceret M200 (Considering
minimum cement content 340 Kg/Cumt.) and curing complete excluding
the cost of formwork, centering, shuttering, Scaffolding, stuting and
propping etc. in shape and size and removal of the same etc. complete at
all floor and all levels as directed by EIC.
15 Slabs, landing, Shelves, Balconies (more than 10 tone ) 115 Cmt. 4461
Providing and laying controlled cement conceret M200 (Considering
minimum cement content 340 Kg/Cumt.) and curing complete excluding
the cost of formwork, centering, shuttering, Scaffolding, stuting and
propping etc. in shape and size and removal of the same etc. complete at
all floor and all levels as directed by EIC.
16 lintel 9 Cmt. 4461
Providing formwork of ordinary timber planking so as to give a rough finish
including centering, shuttering, strutting and propping etc. height of
propping and centering below supporting floor to cealing not exceeding
M. and removal of the same for in sity reinforced concrete and plain
concrete work in. (A) Foundations, Footings, Bases of Columns etc., and
17 Mass concrete.(more than 10 tone ) 373 Sq.M. 179
Providing formwork of ordinary timber planking so as to give a rough finish
including centering, shuttering, strutting and propping etc. height of
propping and centering below supporting floor to celiling not exceeding
M. and removal of the same for in sity reinforced concrete and plain
concrete work in. (B) Flat surfaces such as soffits of slabs, Landings and the
18 like. (1) Floors, etc. upto 200 mm in thickness.(more than 10 tone ) 118 Sq.M. 261
Providing formwork of ordinary timber planking so as to give a rough finish
including centering, shuttering, strutting and propping etc. height of
propping and centering below supporting floor to celiling not exceeding
M. and removal of the same for in sity reinforced concrete and plain
concrete work in. (G) Columns, Pillars,Posts and struts. (1) Square,
19 Rectangular, Polygonal in plan.(more than 10 tone ) 365 Sq.M. 313
Providing formwork of ordinary timber planking so as to give a rough finish
including centering, shuttering, strutting and propping etc. height of
propping and centering below supporting floor to celiling not exceeding
M. and removal of the same for in sity reinforced concrete and plain
concrete work in. (H) (1) Sides and soffits of Beams, Beam Haunchings,
cantilevers, Girders, Bressumers and Lintels not exceeding 1 M. in
Depth.(more than 10 tone )
Providing formwork of ordinary timber planking so as to
give a rough finish including centering shuttering
strutting and propping etc. height of propping and
centering below supporting floor to ceiling not exceeding
4 M. and removal of the same for in situ reinforced
concrete and plain concrete work in. (I) Edges of slabs
21 and Breaks in floors and walls. 19 Sq.M. 72
Providing TMT Bar FE 500D reinforcement for R.C.C. work including
22 bending, binding and placing in position complete upto floor two level 80772 kg 77
Brick work using common burnt clay building bricks having
crushing strength not less than 35 kg./Sq.Cm. in foundation
and plinth in Cement Mortar 1:5. (1- Cement : 5 -fine
23 sand)(B) Conventional 4 Cmt. 4153
Brick work using common burnt clay building bricks having crushing
strength not less than 35 kg./Sq.Cm. in foundation and plinth in Cement
Mortar 1:6 (1- Cement : 6 -fine sand) Extra for brick work in superstructure
above plinth level upto floor two
24 level (B) Conventional 102 Cmt. 4122
(i) Half brick masonry in common brunt clay building bricks having
crushing strength not less than 35 Kg/Sq.Cm. in Cement mortar 1:4 (1-
Cement: 4 -coarse sand ) in foundation and plinth ,Extra for brick work in
superstructure above floor two level Item No.
25 (B) Coventional 45 Sqmt. 615
Providing 15 mm thick cement plaster in single coat (Interior Plaster) on
Brick/c.c wall for plastering at all floor and all levels and finishing even and
26 smooth in cement mortar 1:4 etc complete as directed by EIC. 483 Sq.Mt 171
Providing 20mm thick cement plaster in single coat on single or half brick
walls for interior plastering upto floor two level and finished even and
27 smooth in (ii) Cement mortar 1:4 (1-cement :4-sand) 647 Smt 218
Finishing walls with textured exterior paint of required shade :
13.45.1 New work (Two or more coats applied @ 3.28 ltr/10 sqm)
over and including priming coat of exterior primer applied @
Finishing wall with weather proof exterior emulsion paint (with 7yrs.
warranty period) on plastered surface (two coats) to give an required shape
even shade after thoroughly brushing the surface to remove all dirt and
remains of loose powdered materiels etc complete at all floors and all
29 levels as directed by EIC. 1130 Sq.Mt 117
Applying two coats of Birla or Asian acrylic lappy (putty) and two coats of
primer of approved brand and manufacture on new wall surface to give an
even shade including thoroughly brushing the surface free from mortar
dropping and other foreign matter and sand prepared smooth etc complete
30 at all floors and all levels as directed by EIC. 447 Sq.Mt 41
Wall painting (3 coats) with plastic emulsion paint of approved brand and
manufacture on undecorated wall surface to give an even shade including
throughly brushing the surface free from mortar dropping and other
foreign matter and sand papered smooth etc complete at all floors and all
31 levels as directed by EIC. . 483 Sq.Mt 115
Providing and fixing Structural Glazing with using the 17 Micron anodised
of approved colour alluminium section as transium, mullium of size 63mm
x 38mm x 2 mm with using 6 mm thick reflective structural glass of
approved make, colour, toughned and shade and fixed with silicone sealant
and spacer tap and at corner sealed neoprene foam dust and Air sealed
gasket mirred including scaffolding, cleaning of glass etc.complete at all
heights anf lifts with all necessary fitting and fixtures, anchore fasteners,
necessary M.S. or Aluminium brackets, suitable design for openable
window as per Architectural drawing and as directed by Engineer-in-
charge. Grooves between the glasses to be filled with sealant of Dow
corning - structural sealant 995, weather sealant 789. The entire facade
should be water proof. The mullions are to be connected to bracket by SS-
304 nut bolts. Measurement shall be given as per actual execution of the
32 work. 52 Sqmt 3204
Pro. And fixing single layer water proof gypsum board 12.5 mm thick
sections using water proof board of size 1220 mm x 1830 mm x 8.0 mm
suspended by GI suspender channel of size 25 mm x 3 mm with
intermediate channel og size 18 mm x 40 mm x 0.8 mm at 1220 mm center
to center ceiling section of size 40 mm x 35 mm x 0.55 mm at 457 mm c/c
and perimeter channel A of size 20 mm x 27 mm x 30 mm
x 0.5 mm at edges & drops incl.paper tap sand sofit cleat, anchor fastener,
scoch bolt connecting cleat,joining compound top coat on ceiling
incl.making necy.opening for light fitting,diffuser etc. comp. as per detail
33 drawing as directed 423.5 Sqmt 607
P & L 24" x 24" vitrified 8 mm thick tile flooring over 20 mm (average) base
of cement mortar 1:6 ( 1 cement: 6 coarse sand) on new surface, tread of
steps, landing or fixing on existing flooring by adhesive material including
dismentaling of existing flooring and jointed with color cement slurry
including finised with flush pointing & cleaning the surface etc. complete
34 for light shade (upto 10 ton) 446.6 Sqmt 1453
P & L 24" x 24" vitrified 8 mm thick tile flooring over 20 mm
(average) base of cement mortar 1:6 ( 1 cement: 6 coarse sand) on new
surface or fixing on existing flooring by adhesive material including
dismentaling of existing flooring and jointed with color cement slurry
including finised with flush pointing & cleaning the surface etc. complete
35 for antiskit 22 Sqmt 1433
Vitrified Wall Tiles :
Providing and laying Vitrified tiles 8 to 10 mm thick , in skrting risers of
steps and dedo on 10mm thick cement plaster 1:3 (1-cement : 3-coarse
36 sand) and jointed with white cement slurry 72 Sq.Mt 1577
Providing and laying Granite stone flooring in required design and patterns,
in linear as well as curvilinear portions of the building all complete as per
the architectural drawings with 18 mm thick stone slab and 75mm width
granite acid work stripe stone over 50 mm (average) thick base of cement
mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry
and pointing with whitecement slurry admixed with pigment of matching
shade including moulding, rubbing, curing and polishing etc. all complete
as specified and as directed bythe Engineer-in-Charge :a. Flamed finish
granite stone slab Jet Black, Cherry Red, Elite Brown,Cat Eye or equivalent
37 as approved by Architect. 8 Sqmt. 2697
Providing and fixing 18 mm thick Granite gang saw cut, mirror polished,
premoulded and prepolished, machine cut for kitchen platforms,
vanitycounters, window sills , facias and similar locations of required size,
approved shade, colour and texture laid over 20 mm thick base cement
mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement,
mixed with matching pigment, epoxy touch ups, including moulding,
rubbing, curing, and polishing to edges to give high gloss finish etc.
complete at all levels.
38 8.2.2.2 Area of slab over 0.50 sqm 52 Smt. 2697
Supplying cutting, bending, binding and placing in position steel as per plan
and design and as per ISS 2502 including cost of steel and binding wire for
reservoirs/structures only including lift up to 6 meter height or depth
below G.L. for all diameters CRS steel all diameter Fe 500grade confirming
39 to relevant I.S 3490 Kg. 79
PROVIDING & LAYING 80MM THK.RUBBER MOULDED
INTERLOCKING PAVER BLOCKS(M-45 GRADE) 50 MM
THICK SAND BED INCL. COMPACTION WITH MECH.
COMPECTOR IN LINE , LEVEL AND COLOUR AND DESIGN
40 AS SELECTED BY ENGINEER INCHARGE (APPROVED R.A. 170 SQM 789
Providing and fixing pre-cast concrete kerb stone of gray cement based
concrete block 30cm length,30cm height and 15cm thick of M250
grade concret as per approved design and including excavation for
fixing in proper line and level,filling the joint with C:M 1:3
41 (1cement:3fine sand) etc complete. 48 Sq.Mt 371
Provoding and fixing flush door shutters, solid core construction with frame
of first class hardwood with cross band and face veneer or plywood face
panels,laminate,Batten patti including anodised alluminium butt hinges
eith necessary screws. (B) Non-decorative type and block board core
42 anodised alluminium butt hinges in flush door shutters (2) 35 mm thick. 9 Sqmt. 1830
Providing and fixing FRP frame size 100x50mm and 28mm thick FRP
depress panel shutter having extra reinforcement on sides & edges in Gel
coat finish. The core of the shutter & frame is to be filed up with injected
fire retaedant grade polyurethen form done in situ alongwith embedded
wooden piece for stiffening & also taking hinges & fintures. The whole FRP
frame & shutter is to be water proof weather proof, termite proof &
resistance to mild acid/alkali. Rates are to be inclusive of S.S. hinges with
43 necessary screws & alluminium fixtures & fastenings & fastener sleeved. 9 Sqmt. 2378
Providing and fixing standared extruded of alluminium section of size
63mm x 38.10mm x 1.2mm @ Wt. 0.643 Kg/mt with colour anodized
alluminium frame for ventilation with 5 mm thick frosted glass as details
44 etc complete for Ventilation 17 Sq.Mt 1176
Providing and fixing standared extruded of alluminium
section of size 63.50 x 38.10 x 1.95 mm @ Wt 1.094Kg /
Rmt with colour anodized alluminium frame with 5 mm
thick transparent bronze colour tinted float glass with
colour anodized alluminium frame for ventilation with
mm thick frosted glass as details etc complete
45 for.window 301 Sq.Mt 1176
Providing and fixing window having extruded aluminum Colour anodized
section frame main outer size 95mm x 24mm x 1.17mm (of Jindal Section
no:2459 @ wt.of 0.738 Kg/mt), horizontal Three track member size 92mm
x 31.75mm x 1.30mm (of Jindal Section no:8688,@ Wt.1.07 Kg/mt), vertical
member of size 92mm x 31.75mm x 1.50mm (of Jindal Section no:8933,@
Wt. 1.06 Kg/mt) with sliding shutters of horizontal member size
mmx18mm x1.29mm (of Jindal Section no:8947@ wt.of 0.456 Kg/mt),
vertical member of size 40mm x 18mm x 1.29 mm (of Jindal Section
no:8949 @ wt.of 0.456Kg/mt/ with 5 mm th transparent bronze colour
tinted float glass with powder coated aluminum fittings & fixtures and
46 transparent silicon sealant glass fixing to frame as per details etc 27 Sqmt. 1592
Providing and fixing M.S. grills of required pattern of windows etc. with
M.S. flats at required spacings and frame alround, square or round bars
47 with round headed bolts and nuts or by screws. (A) Plain Grill. 951 mt 105
Applying priming coat over new steel and other metel surface after and
including preparing the surface by throughly cleaning, oil,grease, dirt and
other foreign matter and scoured with brushes fine steel wood, scrapers
48 and sand paper with ready mixed priming paint brushing red lead. 12 Sqmt. 36
Painting two coats (excluding priming coat) on new steel and other metal
surface with enamel paint, brushing, interior to give an even shade
including cleaning the surface an even shade including cleanicn the surface
49 of all dirt, dust and other foreign matter. 12 Sqmt. 90
PROVIDING AND FIXING CARPET LAWN IN BLOCKS
INCLUDING FIXING WITH FERTILIZER AND CLAY, WITH
ALL TRANSPORTATION, PLANTING ETC
50 COMPLETE.(APPROVED R A of
Preparing structural design ) RCC Under Ground / Partially under ground / 100 Smt 311
above high ground level Reservoir of required capacity as per relevant I.S.s
and constructing the same, including excavation in all types of soil strata
(including rock) including shoring strutting if required, for loose soil / to
protect from collapse due to near by traffic load, casting 100 mm thick
P.C.C., levelling course in M-10, Refilling the pit with proper soil and
disposing of the surplus stuff within a lead of VMC limit, Including cement
plaster in CM 1:2 with approved water proofing compound to inside water
touching surface to container. Including all types of labour and material
charges of lowering, laying, erecting / hosting and jointing of pipe assembly
to inlet, outlet overflow, washout and byepass arrangement as per
hydraulic design.
Providing and fixing accessories like MS / GI ladder, CI Manhole frame and
cover, Water level indicator, adequate cowl type ventilators or lantern type
ventilator with stainless steel jail.
B.B. Masonry chambers for valves, Providing and applying three coats of
cement paint / snowcem to the outside face of structure. It also includes
51 satisfactory water tightness test as per relevant I.S. code and painting 20000 LIT 8
Providing erecting fixing double coated Syntex of Equivalent PVC (ISI) Mark
water tank of required capacity each with all necessary fittings &
52 connection etc.complete on terrace. 20000 Lit 4
Providing and fixing white vitreous china pedestal type water closet
(European type W.C. pan) with seat and lid, 10 litre first quality low level
concealed flushing cistern, including flush pipe, with manually controlled
device (handle lever), conforming to IS : 7231, Jet spray & conceal cock
with all fittings and fixtures complete, including cutting and making good
the walls andfloors wherever required :
53 17.2.1W.C. pan with ISI marked white solid plastic seat and lid 3 Nos. 1336
Providing and fixing wash basin with C.I. brackets, 15 mm S .S . pillar taps,
32 mm C.P. brass waste of standard pattern, includingpainting of fittings
and brackets, cutting and making good the wallswherever require :
17.7.3 White Vitreous China Wash basin size 630x450 mm witha pair of
54 mm S S pillar taps 2 Each 1317
Providing & Fixing urinal of approved quality incl. connection the urinal
with waste pipe, trap,nessesary PVC connection, (A) White Earthenware
55 flact back or corner typesize 430mm x 260mmx 350mm 2 No. 1062
Providing & fixing S S Plated pillar tap, capstan head,screw down high
pressure with screws, shanks and back nuts. pillar cock long neck with
56 aerator - 15mm dia 3 Each 309
Providing and fixing 15mm dia S S Plated screws down Bib Tap etc.
57 complete 5 Each 187
Providing and fixing chromium plated brass half trun flush
cock of approved quality including fixing in pipe line etc.
58 complete.(iii) 32mm dia. 6 No. 3131
Providing and fixing PVC Nahni trap of the following nominal diameter of
self cleaning design with C.I. screed down or hinged gratiing incl. cost of
cutting & making, good the walls and floors 100 mm inlet and 50 mm
59 outlet. 6 Each 633
Providing & fixing 600mm x 750 mm bevelled edge mirror of superior glass
mounted of 6 mm th. PVC sheet or plywood sheet and fixed to wooden
60 pluge with C.P. brass screws and washer 3 Each 855
Providing and fixing C.P. brass towel rail comlete with C.P. brass brackets
61 fixed to wooden plugs with C.P. brass scews.(B) 600mm x 20mm size. 3 Each 616
Providing and fixing PTMT soap Dish Holder having length of 138mm,
breadth 102mm, height of 75mm with concealed fitting arrangements,
62 weighing not less than 106 gms 3 Each 782
Providing and laying in trenches galvanised mild steel tubes (Midium grade)
of the following nominal bore, and tube fitting including fixing, testing of
pipe with joints and also including the cost of necessary fitting etc.
complete as directed by E.I.C. (If Pipe shall be fixed on the wall, so It have
to fixed with the help of clamp at every two meter c/c. or shall be
concealed ) (Earthwork in trenches to be measured and paid for separately)
: 65mm dia.(more than 10 tone)
Providing and jointing in true line and level UPVC pipe (SCH :40) including
fitting make or equivalent as approved by Engineer In Charge Pipe shall be
fixed on the wall with the help of clamp at every two meter c/c. or shall be
concealed as directed including necessary fitting etc. including testing of
pipe and joints and fixing the same with adhesive solvent, including cost of
64 all materials. 50mm dia. 60 Rmt. 196
Providing and jointing in true line and level UPVC pipe (SCH :40) including
fitting make or equivalent as approved by Engineer In Charge Pipe shall be
fixed on the wall with the help of clamp at every two meter c/c. or shall be
concealed as directed including necessary fitting etc. including testing of
pipe and joints and fixing the same with adhesive solvent, including cost of
65 all materials. 25mm dia. 24 Rmt. 92
Providing and jointing in true line and level UPVC pipe (SCH :40) including
fitting make or equivalent as approved by Engineer In Charge Pipe shall be
fixed on the wall with the help of clamp at every two meter c/c. or shall be
concealed as directed including necessary fitting etc. including testing of
pipe and joints and fixing the same with adhesive solvent, including cost of
66 15mm dia. 65 Rmt. 73
Providing, fixing, jointing, testing and commissioning of UPVC pipe with
rubber ring joint confirming to IS : 13592, and confirming to IS : 4985 (Pipe
Class III - 6 kg / sq.cm) cut to required lengths including all necessary
fittings and specials such as bends, junctions offsets, access pieces (plain or
door) . Fixing at wall / ceiling level supported by G.I. clamps, hangers etc.
duly epoxy coated. Cutting chases/holes in floors/walls / slab. The piping
67 should be complete with P or S trap as req. 110mm (10.0 Kg. F/Cm2 15 Rmt 856
Providing and fixing to wall ceiling and floor 10.0 Kg. F/Cm2 working
pressure polythene pipes of the following outside Dia. Low densidy,
complete with special falnge compression type fittings, wall clipsetc.
68 including making good the wall ceiling and floor.(F) 75mm(10.0 Kg. F/Cm2 8 Rmt 280
Providing and fixing Gun metal check or non-return fullway
69 wheel valve.(E) 40mm dia.(23.99) 4 Each 663
70 Providing and fixing Slotted cowl (terminal guard ) 110 mm dia 4 Nos. 20
71 Providing and fixing Slotted cowl (terminal guard ) 75 mm dia 4 No. 9
Providing & fixing S.W. Gully trap with C.I. grating brick masonry chamber
& water tight C.I. cover with frame of 300 mm x 300 mm size ( inside) with
72 standard weight. (B) 150 mm x 100 mm size 'P' or 'R' type 5 NOS. 1292
Constructing brick masonry chamber for underground C.I. inspection
chamber and bends with brick having crushing strength not less than
Kg./Cm2. in C.M. 1 : 5 C.I. cover with frame (light duty) 455 x 610 mm.
internal dimensions, total weight of cover with frame to be not less than
Kg. (Wt. or cover 23 Kg. and Wt. of frame 15 Kg.) R.C.C. top slab with C.C.
: 2 : 4 mix (1 cement : 2 coarse sand : 4 graded aggregate 20 mm. size)
foundation concrete 1 : 5 : 10 inside plaster 15 mm. thick with C.M. 1 :
finished smooth with a finishing coat of neat cement on walls and bed
concrete etc. complete. ( Inside Dimensions 500mm x 700 mm & 450 mm
73 deep for single pipe lines with one or two inlets. 5 Each 3661
Extra over items 24.44 for every additional depth of 0.1M. of part thereof
beyond 450mm depth for Brick masonry chamber.(ii) for 500mm x 700mm
74 size. 5 Each 265
Construction Manhole with 150mm th. R.C.C. top slab in 1 : 2 : 4 mix (1
cement : 2 coarse sand : 4 graded stone aggregate 20 mm. nominal size)
foundation concrete 1 : 3 : 6 (1 cement : 3 coarse sand : 6 brick bats 40 to
50 mm. size) inside plastering 15 mm. thick with C.M. 1 : 5 (1 cement :
coarse sand) finished with floating coat of neat cement and making
channels in C.C. 1 : 2 : 4 (1 cement : 2 coarse sand : 4 stone aggregate
mm. nominal size) finished smooth complete incl. curing and testing (1)
inside size 900 mm. x 1200 mm. and 1.5 mt. deep including C.I. cover with
frame size.560 mm diameter total weith of cover & frame to be not less
than 128 kg, (Wt. of cover 64 kg. & Wt. of frame 64 kg) (A) with 230 mm
th. Walls of brick masonry using brick having crushing strength not less
than 35 kg./Sq.cm in cement mortar 1 :5 (1cement : 5 coarse sand)
75 (2) B type depth 1.50 Meter for 150mm diameter sewer. 2 Each 19350
(II) Extra rate for constructing B.B. masonry for every additional depth of
0.1M. GR Part thereof over item No.24.27 (I) for depth from 1.50M. to
Providing and laying Cement concrete 1:5:10 (1-Cement : 5-Fine sand :10-
Graded stone aggregate 40mm nominal size) bedding for stoneware pipes
of following internal diameters with necessary formwork and curing
77 complete. (B) 150mm dia. (166mm Ave. bed thickness 22 Rmt. 214
Providing and laying Cement concrete 1:5:10 (1-Cement : 5-Fine sand :10-
Graded stone aggregate 40mm nominal size) bedding for stoneware pipes
of following internal diameters with necessary formwork and curing
78 complete. (A) 100 mm dia. (112 mm Ave.bed thickness) 44 Rmt. 127
Providing and laying (to level or slopes) and jointing with stiff mixture of
Cement Mortar in proportion 1:1, Salt glazed stoneware pipes including
79 testing of pipes and joints complete. (B) 150mm dia.(more than 10 tone) 44 Rmt. 214
Providing and laying (to level or slopes) and jointing with
stiff mixture of Cement Mortar in proportion 1:1 Salt glazed
stoneware pipes including testing of pipes and joints
80 complete. 200mm dia 66 Rmt. 313
Providing and Supplying ISI standard RCC pipes (of Sulphate Resistance
Cement ) in standard length of following class and diameter suitable for
Rubber ring joint including all taxes,insurance ,transportation ,freight
charges,octroi,inspection charges ,loading ,unloading ,conveyance to site
/Departmental store ,stacking etc. complete .(IS-458/1989,suitable for
tyton joint including cost of supply of joint mat,rubber ring . for Horizontal
81 cast /vertical cast as mentioned. 300 mm dia 33 Rmt. 727
Providing and Supplying ISI standard RCC pipes (of Sulphate Resistance
Cement ) in standard length of following class and diameter suitable for
Rubber ring joint including all taxes,insurance ,transportation ,freight
charges,octroi,inspection charges ,loading ,unloading ,conveyance to site
/Departmental store ,stacking etc. complete .(IS-458/1989,suitable for
tyton joint including cost of supply of joint mat,rubber ring . for Horizontal
cast /vertical cast as mentioned.
82 450 mm dia 22 Rmt. 1659
Lowering laying and jointing RCC pipe for Rubber ring push on joint with
CM 1:1.5 vata of following diamtere including excavation in proper
position,grade alignement as directed by Engineer in charge includig
conveyance from store to site of work , all labour complete . ( Including
performing sucessful flow test ) including all cost of jointing material
83 300mm dia 33 Rmt. 120
Lowering laying and jointing RCC pipe for Rubber ring push on joint with
CM 1:1.5 vata of following diamtere including excavation in proper
position,grade alignement as directed by Engineer in charge includig
conveyance from store to site of work , all labour complete . ( Including
performing sucessful flow test ) including all cost of jointing material
84 450mm dia 22 Rmt. 173
Providing and fixing stone slab with table rubbed, edges rounded and
polished, of size 750mm (h) x500 mm (w) and 18 mm thick, fixed in Urinal
Partitions by cutting a chase of appropriate width with chase cutter and
embedding the stone in the chase with epoxy grout or with cement
concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 6 mm
nominal size) as per direction of Engineer-in-charge and finished smooth.
85 8.10.2 Granite Stone of approved shade 1 Sqmt. 2697
Providing And Placing: Fix Multi-Purpose Fabric Chair Specification: Office
Seating Type: * All Over Size Is : 580mm(L)X 760mm(D)X 930mm(H) , *The
Chair Made Of Full Fabric In Black Colour . It Will Comes In Matte Finish In
Contemporary Style. Details: * Arms: Fixed Armrests. * Use Of Ply: 12 Mm
Thick Hot Pressed Bwr Plywood (Is Grade - 303 For Seat And Back) . * Seat:
40 ± 2 Mm Thick Polyurethane Foam With Density 32 (±3) Kg Per Cu Meter
For Best Quality Cushioning In Seat, * Back : 40 ± 2 Mm Thick Polyurethane
Foam With Density 32 (±3) Kg Per Cu Meter For Best Quality Cushioning In
Back . Backrest Support Foam Design Based On Symmetrical Lumbar
Support Seat Max Height Is @ 930mm . * Base : 4 Legs Metal Powder
Coated . * The Product by The Seller / Company Should Be Iso 9001:2008,
guard, Green Pro, Aiota, Indian Design Mark And Fsc Certified. The Bidder
Should Be A Member Of Bifma And At Least Two Products Of The Oem
Should Be Certified As Bifma Compliant And An Official Product Official
Link/Screenshot Of The Product Listing Must Be Provided From
86 Www.Bifma.Org". 122 nos. 2649
Providing & making computer table of requred size 0.75 mt width including
keyboard slide channel board cup board cpu cabinet with lock ,handle, top
87 laminate ,border putty and colour etc complete 28.8 RMT 4373
Providing and supply 2 Door Sliding Cub Board-LIB 1003 - Size: 1981 x 914 x
483mm Steel LibraryCupboard construction CRCA sheet 20 Gauge, Door
Outer Body CRCA sheet 22 gauge, Door partli 4mm thick visible gass with
and locking mechanism with hardware. with 4 adjustable shelf CRCA
making five comparments, Uniformly Distributed load capacity per each
40 Kg maximum, finished with epoxy powder coated to the thickness of
88 microns, including all necessary fixtures, fastners machinary etc. 6 nos. 12373
Supplying & placing in position of table of size:- L-1500mm x D-900mm x H-
750mm as per photograph.The table top shall be made out of25mm thk.
PRELAMINATED PARTICLE BOARD tabletop with PVC edge banding.
Tabletop supported with Powder coated "C" shape metal legs of size
50mm x 50mm and connectors of size 40mm x 40mm. . The product shall
be from ISO 9001:2015,ISO 50001:2011, ISO 14001, OHSAS 18000 , BIFMA,
FSC, AIOTA, SEDEX & Greenguard Certified company and complete as per
89 the approved sample and as per the direction of Engineer-In-Charge. 23 Nos. 18433
Steel work, welded in built up sections framed work including cutting,
hoisting, fixing in position and applying a priming coat of red lead paint.
(A)In beams and joists, channels angles Tees, flats, with connecting plates
or angle cleats as in main and cross beams. Hip and jack rafters, purlins
90 conneted to common rafters and the like 22.34 Q 9108
Providing and laying precast terrazo tiles 20mm thick with marble chips of
sizes. upto 6mm in skirting and risers of steps not exceedings 30 cms. in
height on 10mm thick cement plaster 1:3 (1-cement : 3- coarse sand )
jointed with neat cement slurry including rubbing and polishing complete
91 with tiles of. (A) Light shades using white cement 806 Sqmt 667
Extra over items for providing and mixing water proofing materials in used in
92 cement mortar in proportion recommended by the manufacturer 170 mix 49
Providing and fixing 12 mm thick frameless toughened glass door shutter
of approved brand and manufacture, including providing and fixing top &
bottom pivot & double acting hydraulic floor spring type fixing
and making necessary holes etc. for fixing required door fittings, all
complete as per direction of Engineer-in-charge (Door handle, lock and
93 stopper etc.to be paid separately). 300.7 SQ.MT 5379
6Supplying and fixing 6 Kg ABC type fire extinguisher suitable for residential
use, ISI marked as per IS:15683, filled with mono ammonium phosphate-
based dry chemical powder, suitable for Class A (solid), Class B (liquid), and
Class C (gas) fires. The extinguisher shall be complete with pressure gauge,
discharge hose/nozzle, safety pin, wall mounting bracket, and operating
instructions printed on the body. It shall be of approved make (such as
Safex / Ceasefire / Kanex / Minimax or equivalent), having a minimum fire
rating of 3A:40B, with at least one year warranty. The item rate shall
include all taxes, transportation, installation at site, and demonstration to
94 the user. 22 Nos. 3156
Point wiring for Light / Bell with 2-1.5 sq.mm & earth wire of 1.5 sq.mm
(Green) both are of ISI marked 1.1 KV grade FRLS PVC insulated multi
strand copper wires up to 10 mtr length , in below type of pipe erected
with 6A Modular type switch / bell push & accessories and earth continuity
of following type, erected on PVC / Metallic/Wooden box, single mounting
base frame covered with textured/metallic/white front plate modules
erected on / in wall / ceiling as per pipe erected, with necessary Lamp
holder/ceiling rose / H.D.Connector as directed.
(f) with medium class Rigid PVC pipe and accessories erected concealed in
wall/ceiling complete(catIII)
Point wiring for secondary light point with 2-1.5 sq.mm & earth wire of
sq.mm (green) both are of ISI marked 1.1 KV grade FRLS PVC insulated
multi strand copper wires, in below type of pipe to be erected complete
with earth continuity and necessary connection with primary light with
accessories erected on Metal / PVC / wooden box covered with 3 mm
thick PC(Polycarbonate) / Acrylic sheet for open / concealed wiring. with
necessary Lamp holder / ceiling rose / H.D.Connector as directed.
Note:- Maximum up to 6 mtrs length, excess will be considered as Mains
for Secondary Point.
(f) with medium class Rigid PVC pipe and accessories erected concealed in
96 wall/ceiling complete. 20 nos 153
Point wiring for FAN with 2-1.5 sq.mm & earthwire of 1.5 sq.mm (Green)
both are of .ISI marked 1.1 KV Grade FRLS PVC insulated multistrand
copper wires, in below type of pipe erected with 6A Modular type switch
and hum free EME four or more step type electronic fan regulator with
separately mounted and accessories with earth continuity of following
type erected on PVC / Metallic/Wooden box, single mounting base frame
covered with textured/metallic front plate modules erected on / in wall /
ceiling as per pipe erected. with necessary ceiling rose / H.D.Connector as
directed. (f) with medium class Rigid PVC pipe and accessories erected
97 concealed in wall/ceiling complete. cat III. 60 nos 635.46
Point wiring for Two Way Controlled Light Point with 2-1.5 sq.mm & earth
wire of 1.5 sq.mm (green) both are of .ISI marked 1.1 KV grade FRLS PVC
insulated multi strand copper wires erected in below type of pipe with 6A
Modular type switches and following type of accessories erected on PVC /
Metallic/Wooden box, single mounting base frame covered with textured /
metallic/white front plate modules erected on / in wall / ceiling as per pipe
erected. with necessary batten/angle holder or ceiling rose or
H.D.Connector as directed. (f) with medium class Rigid PVC pipe and
98 accessories erected concealed in wall/ceiling complete. cat III. 10 nos 566.1
Point wiring for on board Looped Plug with 6A Modular type switch & 5 pin
socket erected on PVC / Metallic/Wooden box, single mounting base frame
covered with textured / metallic/white front plate modules erected on /
99 in wall / ceiling with following type accessories. cat III. 30 nos 243.78
Point wiring for Individual Plug with & earth wire of 1.5 sq.mm (Green)
both are of ISI marked 1.1 KV grade FRLS PVC insulated multi strand copper
wires up to 10 mtr length, in below type of pipe erected complete with
Modular type switch & 5 pin Plug erected on PVC / Metallic/Wooden box
covered with appropriate front plate modules erected on / in wall / ceiling
as per pipe erected with following type of accessories. [I] For 6A Plug with
2-1.5 sq.mm Cu. Wire.(f) with medium class Rigid PVC pipe and accessories
100 erected concealed in wall/ceiling complete. cat III. 12 nos 478.38
Point wiring for Individual Plug with & earthwire of 1.5 sq.mm (Green)
both are of ISI marked 1.1 KV grade FRLS PVC insulated multistrand copper
wires, in below type of pipe erected complete with Modular type switch &
5 pin Plug erected on PVC / Metallic/Wooden box covered with
appropriate front plate modules erected on / in wall / ceiling as per pipe
erected with following type of accessories. [II] For 16A Plug with 2-2.5
sq.mm Cu. Wire. (f) with medium class Rigid PVC pipe and accessories
101 erected concealed in wall/ceiling complete. cat III. 20 nos 704.82
Point wiring for Individual Plug with & earthwire of 1.5 sq.mm (Green)
both are of ISI marked 1.1 KV grade FRLS PVC insulated multistrand copper
wires, in below type of pipe erected complete with Modular type switch &
5 pin Plug erected on PVC / Metallic/Wooden box covered with
appropriate front plate modules erected on / in wall / ceiling as per pipe
erected with following type of accessories. [III] For 16A Plug and 16 amp
switch with 2-4 sq.mm Cu. Wire with 2.5 sq.mm ( green) earthing wire
from mcb d b board.. (f) with medium class Rigid PVC pipe and accessories
102 erected concealed in wall/ceiling complete. cat III. 12 nos 826.2
Providing & erecting Switch board for Computer or electric apparatus
consisting of following modular type accessories mounted with PVC /
Metallic concealed/open box with single mounting base frame covered
with textured/metallic /white front plate,modules erected with necessary
connections as directed
1 no. 6A/16A universal plug-switch combined.
3 nos. 6A Switch
103 3 nos. 6A 5 pin Plug . For Modular Type Accessories. Cat III. 35 nos 1092.4
SITC of Face Plate - Single (Keystone Jack,square) (Including Five year free
104 maintenance with guarantee). 20 nos 91.8
SITC of Jack Cat 6 Keystone UTP (Including Five year free maintenance with
105 guarantee) 50 nos 163.2
Supplying & erecting approved make LAN cable of following size in existing
106 pipe as per direction. [C] CAT - 6. for LAN points & for cctv points. 500 mtrs. 45.9
Providing & Erecting 6 core fibre optic SM 9/125um double sheath, CSTA,
107 Unitube, Outdoor cable (per m). 150 mtrs. 59.16
Providing following type of Modular Type Accessories mounted with PVC /
metallic/Wooden box, single mounting base frame covered with textured /
metallic/white front plate , modules erected with necessary connections
as per site situation directed by Engineer In charge. (3) Two Pin/RJ-11
108 Telephone Socket. [B] For Two Gang. Cat III. 5 nos 202.98
Providing and erecting ISI mark Medium class RIGID PVC PIPES of following
size complete to be erected on/in wall or ceiling erected with necessary
PVC fittings & Junction boxes fixed with adhesive solution & Clamps with
109 following dia of pipes, in approved manner as directed. (b) 25 mm. 200 mtrs. 32.64
Providing & erecting PVC Corrugated Flexible Conduit with required nos. of
coupling, PVC bushes, Check-nuts etc. complete of following sizes. (1)
Providing & erecting PVC Corrugated Flexible Conduit with required nos. of
coupling, PVC bushes, Check-nuts etc. complete of following sizes. (2)
Mains with 1.1 KV grade FRLS PVC insulated ISI marked stranded Copper
conductor wire in following type of pipe to be erected concealed in
/flushed on wall/ceiling, with 1.5 sq. mm copper conductor FRLS PVC
insulated stranded wire of green colour for earth continuity of following
size (a) with medium class Rigid PVC pipe and accessories (b) 2 wire 2.5 sq.
Mains with 1.1 KV grade FRLS PVC insulated ISI marked stranded Copper
conductor wire in following type of pipe to be erected concealed in
/flushed on wall/ceiling, with 1.5 sq. mm copper conductor FRLS PVC
insulated stranded wire of green colour for earth continuity of following
size (a) with medium class Rigid PVC pipe and accessories (a) 2 wire 1.5 sq.
Mains with 1.1 KV grade FRLS PVC insulated ISI marked stranded Copper
conductor wire in following type of pipe to be erected in / on wall / ceiling
with 2.5 sq. mm copper conductor FRLS PVC insulated stranded wire of
green colour for earth continuity of following size (A) with medium class
114 Rigid PVC pipe and accessories (a) 2 wire 4 sq. mm. 150 mtrs. 108.12
Mains with 1.1 KV grade FRLS PVC insulated ISI marked stranded Copper
conductor wire in following type of pipe to be erected in / on wall / ceiling
with 2.5 sq. mm copper conductor FRLS PVC insulated stranded wire of
green colour for earth continuity of following size. (a) with medium class
115 Rigid PVC pipe and accessories (b) 2 wire 6 sq. mm. 50 mtrs. 141.78
Supply, Installation, Testing and Commissioning of suitable sweep, BEE
Star rated, Ceiling fan with Brush Less Direct Current (BLDC) permanent
ferrite magnet Motor, class of insulation: B, Rust free 3 nos.Aluminium
blades, 2 nos. canopies, shackle kit with earthing provision, copper
winding, Power factor not < 0.9, Service Value (CMM/W) minimum 6.85,
Air delivery minimum 215 CMM, 350 RPM,230v (tolerance as per IS : 374-
2019), THD < 10%, with remote unit for Speed Control and all remaining
accessories including safety pin, nut bolts, washers, temperature rise =
degree C (Max.), suitable for 140 to 285 Voltage and rectifier circuit with
surge, over current and overload protection , 50 Hz, Single phase AC
Supply, earthing etc. Complete as required. [ Make shall be approved by
116 Engineer in Charge] .(B)1200mm sweep(48") 20 nos. 2914.1
Supplying and erecting approved make double ball bearing oscillating type
Heavy duty bracket fan with Aluminium Blades A.C. 23OV. 50cy/s wall
mounted with height adjustment and rotary tilting device complete with
117 guard, wall bracket,mounting accessories as directed. A-450MM 40 mtrs. 4999
Supplying and erecting 19 / 20 mm. nominal bore Medium Class M.S. Pipe
down rod erected duly painted for fan complete with proper insulation
118 without leckage and earthing. 20 N0S. 109.14
Supplying & erecting fan hook box of 10 mm M.S. round bar bounded to
the RCC bars up to 50mm length each side and pierced through a 16 Gauge
M.S. box / Heavy Duty PVC box complete erected concealed in Ceiling with
119 necessary finishing. 20 nos. 109.14
Supplying & erecting single phase approved make industrial exhaust fan
suitable for medium duty ring mounted low noise operation suitable for
medium duty having following dia size and maximum speed in RPM
[E] 450 mm dia 1400 RPM.
Supplying & erecting approved make low noise decorative exhaust fan
having square frame ABS body with inbuilt lowers & square frame. 200mm
121 with 1350RPM Cat.II. 3 nos. 1720.7
122 Decorative call bell Ting-tong box type 250 volts complete erected. 2 nos. 69.36
Providing & erecting 240 V MCB double pole switch for motor & inductive
load (C Curve) having 10 KA breaking capacity & confirms to IS : 8828 in
existing box having following capacity. - use for AC control.
123 (A) 6 to 32 Amp. cat III. 8 nos. 302.94
Sheets steel powder coated enclosure suitable for incorporating One/Two
124 nos. MCB. - use for AC control. 5 nos. 178.5
Providing & erecting 415 V MCB Four Pole for Motor & Inductive Load (C
Curve) having 10KA breaking capacity & confirms to IS :8828 in existing box
having following capacity
125 (a) 6 to 32 Amp. cat III. 2 nos. 601.8
Providing and erecting Sheet Steel powder coated MCB distribution board -
flush / surface mounted fitted with busbar, neutral link, earth bar and DIN
rail, Conforms to IS 8623-1 & 3, IEC 61439-1 & 3 without MCB to house
appropriate nos. of MCBs.(The DBs should be used of same company of
MCB to be used) suitable for (A) single phase incoming and horizontal
126 single phase outgoing (b) sheet steel double door (IP-43) (i)4 way 5 nos. 635.46
providing and erecting Miniature circuit breaker single pole 0.5A to 2A
system and having breaking capacity 10 KA to be erected in existing box.
127 confirming to IS 8828/1996 with ISI Mark 25 nos. 273.36
Providing & erecting 240 V MCB double pole switch for motor & inductive
load (C Curve) having 10 KA breaking capacity & confirms to IS : 8828 in
128 existing box having following capacity. (B) 40 Amp. cat III. 2 nos. 333.54
providing and erecting Approved make RCCBs conforming to IS: 12640 and
having sensitivity of 30 mA and Short Circuit withstand capacity of 10 KA
and suitable for operation on single phase 240 V,50Hz. having
characteristic of quick action & tripping with all advance feature & do not
incorporate any electronic component. for following Max. rating erected
129 as directed(i) 25 Amps.DP. cat III. 4 nos. 1989
providing and erecting Approved make RCCBs conforming to IS: 12640 and
having sensitivity of 30 mA and Short Circuit withstand capacity of 10 KA
and suitable for operation on single phase 240 V,50Hz. having
characteristic of quick action & tripping with all advance feature & do not
incorporate any electronic component. for following Max. rating erected
130 as directed(ii) 40Amps. DP . cat III. 2 nos. 2257.3
Providing and erecting Approved make RCCBs conforming to IS: 12640 and
having sensitivity of 30 mA and Short Circuit withstand capacity of 10 KA
and suitable for operation on 3 phase and neutral 415V,50Hz. having
characteristic of quick action & tripping with all advance feature & do not
incorporate any electronic component for following Max. rating erected as
131 directed. (ii) 40Amps. FP. cat III. 1 nos. 2663.2
Providing & erecting 415V MCB Four Pole Switch for Lighting Load (B curve)
having 10KA breaking capacity & confirms to IS :8828 in existing box having
following capacity
(a) 6 to 32 Amp
132 Cat.III . 1 nos. 584.46
133 Half / One Module Blanking Plate of Standerd Size. 12 nos. 9.18
Providing and erecting Sheet Steel powder coated MCB distribution board -
flush / surface mounted fitted with busbar, neutral link, earth bar and DIN
rail, Conforms to IS 8623-1 & 3, IEC 61439-1 & 3 without MCB to house
appropriate nos. of MCBs.(The DBs should be used of same company of
MCB to be used) suitable for (A) single phase incoming and horizontal
134 single phase outgoing. (b) sheet steel double door (IP-43) (iii) 8 way. 1 nos. 1163.8
Providing and erecting Sheet Steel powder coated MCB distribution board -
flush / surface mounted fitted with busbar, neutral link, earth bar and DIN
rail, Conforms to IS 8623-1 & 3, IEC 61439-1 & 3 without MCB to house
appropriate nos. of MCBs.(The DBs should be used of same company of
MCB to be used) suitable for (B) single phase incoming and horizontal
135 single phase outgoing. (b) sheet steel double door (IP-43) . (iv) 12 way . 1 nos. 3912.7
Providing and erecting Sheet Steel powder coated MCB distribution board -
flush / surface mounted fitted with busbar, neutral link, earth bar and DIN
rail, Conforms to IS 8623-1 & 3, IEC 61439-1 & 3 without MCB to house
appropriate nos. of MCBs.(The DBs should be used of same company of
MCB to be used) suitable for (B) three phase incoming and single phase
horizontal type outgoing Per phase isolation type (PPI). (b) sheet steel
Providingdoor. (ii)6 way.
& erecting weather proof, dust & vermin proof, floor mounted 2 nos. 2942.7
front operated indoor type cubical panel board having necessary IP-42
protection & above as per requirements made from 14 SWG thick CRC M.S.
sheet for outer body & doors, 16 SWG thick CRC M.S.sheet for internal
partitions with necessary supporting angles, flats including cutting,
bending, drilling, welding, riveting with internal partitions & cable alley as
per requirements & instruction of engineer-in-charge with erection of
supplied switch gears, BUSBARS, with suitable size of inter connecting PVC
copper wire / copper-aluminium strips, rubber grommets, rib, bakelite
control fuses for measuring instruments, earth bus & earth bolts,
foundation flange - bolts-base Plates, sufficient nos. of hinged doors,
handles with locking arrangement and rubber gasket, heavy duty end
terminal connections complete. The Panel shall be painted with epoxy
powder coating. (The rates excludes the cost of switchgears, bus bars, inter
connecting mains & Copper Aluminium strips, meters, Fuses etc. The
dimension shall be measured excluding base beams) The panel shall be
supplied with following approved manufacturers with following size.
137 (B) The standard companies switch gear shall be used and only 2 Sqm. 19580
Mains with ISI marked, 1.5KV grade electrolyte multi stranded, annealed
copper conductor with heat resistant PVC insulated conforms to IS 694, IEC -
227 erected in existing pipe of following size (Specifically for control panel,
relays, power switchgears, motor starters & control wiring) with required
size of copper lugs, nuts and bolts if required.
138 (b) One wire 1.50 sq. mm. 10 mtrs. 16.32
Mains with ISI marked, 1.5KV grade electrolyte multi stranded, annealed
copper conductor with heat resistant PVC insulated conforms to IS 694, IEC -
227 erected in existing pipe of following size (Specifically for control panel,
relays, power switchgears, motor starters & control wiring) with required
size of copper lugs, nuts and bolts if required.
139 (d) One wire 4.00 sq. mm. 20 mtrs. 35.7
Mains with ISI marked, 1.5KV grade electrolyte multi stranded, annealed
copper conductor with heat resistant PVC insulated conforms to IS 694, IEC -
227 erected in existing pipe of following size (Specifically for control panel,
relays, power switchgears, motor starters & control wiring) with required
size of copper lugs, nuts and bolts if required.
140 (e) One wire 6.00 sq. mm. 20 mtrs. 54.06
Mains with ISI marked, 1.5KV grade electrolyte multi stranded, annealed
copper conductor with heat resistant PVC insulated conforms to IS 694, IEC -
227 erected in existing pipe of following size (Specifically for control panel,
relays, power switchgears, motor starters & control wiring) with required
size of copper lugs, nuts and bolts if required.
141 (f) One wire 10.00 sq. mm. 20 mtrs. 88.74
Mains with ISI marked, 1.5KV grade electrolyte multi stranded, annealed
copper conductor with heat resistant PVC insulated conforms to IS 694, IEC -
227 erected in existing pipe of following size (Specifically for control panel,
relays, power switchgears, motor starters & control wiring) with required
size of copper lugs, nuts and bolts if required.
142 (g) One wire 16.00 sq. mm. 10 mtrs. 136.68
Mains with ISI marked, 1.5KV grade electrolyte multi stranded, annealed
copper conductor with heat resistant PVC insulated conforms to IS 694, IEC -
227 erected in existing pipe of following size (Specifically for control panel,
relays, power switchgears, motor starters & control wiring) with required
size of copper lugs, nuts and bolts if required.
143 (h) One wire 25.00 sq. mm. 6 mtrs. 227.46
Providing and erecting Approved make Four pole moulded case circuit
breaker having breaking capacity ICU of 35 KA. at 415 V. having Normal
current rating 200A.with variable Thermal & magnetic release suitable to
work on A.C.supply 50 c/s. with all internal connections, spreader tinned
copper & complete erected in existing 16 G.M.S.housing.
144 ICS=100% of ICU only Cat III 1 nos. 16382
Approved make Earth fault Relay suitable to mount with inter connection
to moulded case circuit breaker having CT ratio & MCCB rating as following
along with shunt trip 220V AC. with all internal connections & complete
erected in existing M.S.housing.
Supplying & erecting approved make Four Pole 415V change over switch
interior for panel mounting with operating mechanism A.C.23 duty
confirming to IS for
146 Cat-lll 1 nos. 7867.3
Supplying and erecting triple pole & neutral 440V / 500V panel mounting
Copper Busbars with four equal Nos. of electrolyte bus having current
density not more than 1.6 Amp. / sq.mm (Rated current / cross section
area) duly wrapped with colour insulating tape for phase sequence of
following current carrying capacity, erected with necessary bus bar
supports /insulators, main cable socket to each bar, erected in existing
cubical panel with necessary connections.
147 (B) Suitable for 200 Amp. capacity . 6 mtrs. 3234.4
Supplying and erecting approved make panel mounting type Digital
Voltmeter having 3 digits LED display, 0 to 750 AC Volts range erected on
existing panel board with all connection, wiring etc .with manufacturers
148 calibration certificate. 3 nos. 1288.3
Supplying and erecting approved make panel mounting type Digital
Ammeter having 3 digits LED display, external CT operated, calibrated for
0 to 1000 Amps suitable to operate on 500 Volt AC , erected on existing
panel board with all connection, wiring etc .with manufacturers calibration
149 certificate. 2 nos. 1573.9
Supplying and erecting Ammeter / Voltmeter selector switch for 3 phase
150 AC Supply 500 V on existing panel board with necessary connections. 4 nos. 320.28
Supplying and erecting approved make suitable panel indicator LED type
151 lamp, lens cover, complete erected with necessary connections. 5 nos. 43.86
providing and erecting Miniature circuit breaker single pole 6A to 25A
suitable to operate on 240 V A.C. system and having breaking capacity
KA to be erected in existing box. confirming to IS 8828/1996 with ISI Mark
152 Cat.III 10 Ea. 113.22
Providing and erecting Approved make Four pole moulded case circuit
breaker having breaking capacity ICU of 25 KA. at 415 V,having normal
current rating up to 25 A to 100A. with Fixed thermal & magnetic release
suitable to work on A.C. supply 50 c/s. with all internal connections,
spreader tinned copper & complete erected in existing 16 G.M.S. housing.
153 ICS=100% of ICU only Cat III 3 Ea. 6234.2
Supplying & erecting in earthpit of minimum bore dia. 225mm size ASH or
approved make Safe Earthing Electrode consisting Pipe-in-Pipe
Technology as per IS 3043-1987 made of corrosion free G.I.Pipes having
Outer pipe dia of 80 mm having 80-200 Micron galvanising, Inner pipe dia
of 40 mm having 200-250 Micron galvanising, connection terminal dia of
14 mm with constant ohmic value surrounded by highly conductive
compound with high charge dissipation suitable for following type of
applications. [B] For Electrical installation up to 11 KV located in other
than normal soil i.e. Soft Rock, Marshy Soil etc.
-Length of Pipe : 2 mtr
154 -Back filling Compound :1 no. Bag of 25 Kg. 6 nos. 7165.5
Supplying & erecting in earthpit of minimum bore dia. 225mm size ASH or
approved make Safe Earthing Electrode consisting Pipe-in-Pipe Technology
as per IS 3043-1987 made of corrosion free G.I.Pipes having Outer pipe
dia of 80 mm having 80-200 Micron galvanising, Inner pipe dia of 40 mm
having 200-250 Micron galvanising, connection terminal dia of 14 mm
with constant ohmic value surrounded by highly conductive compound
with high charge dissipation suitable for following type of applications
[C] For Electrical Installation covering Transformer Neutrals, Lightning
arrester Earthing, A.C.Plant & Sensitive Computer System(like
Automation, SCADA)i.e. independent Earthing located in other than
normal soil i.e. Soft Rock, Marshy Soil etc..
-Length of Pipe : 3 Mtrs.
155 -Back filling Compound :2 nos Bags of 25 Kg. 2 nos. 10699
156 Providing and erecting Annealed bare Copper wire 8 to 16 SWG. 10 kg. 802.74
Providing and erecting required size HOT deep Galvanised iron strip for
earthing of H.T. , OCB/ ACB/ Transformer LT panel board, Motors etc. using
157 proper clamp. 10 kg. 78.54
Providing and erecting XLPE(IS:7098)(I)-88 ISI armoured cable multistrand
Aluminium conductor for 1.1 KV. to be laid on wall with necessary clamps
or in existing trench / pipe of following size of cables(D) 3 1/2 core 70 Sq.
mm ( 35 Sq. mm 1/2 core) (Main cable from transformer to meter panel.
Supplying & erecting XLPE(IS:7098)(I)-88 ISI unarmoured copper cable
159 KV grade to be erected as directed of following size. (N) 4 core 16 Sq. mm 50 mtrs. 731.34
Solder less crimping type Copper lugs conforming to IS suitable for cable of
following size evenly crimped with high pressure tool & connected to
switchgear terminals with brass/cadmium plated nut bolts in an approved
160 manner. (C) 16 Sq.mm. 8 nos. 12.24
Providing and erecting XLPE(IS:7098)(I)-88 ISI armoured cable multistrand
Copper conductor for 1.1 KV. to be laid on wall with necessary clamps or
in existing trench / pipe at road crossing or floor of following size of
cables. (C) 4 core 6 Sq. mm Cu. Conductor YWY cable. (Main feeder Panel
161 to PDB.). 80 mtrs. 513.06
Providing and erecting XLPE(IS:7098)(I)-88 ISI armoured cable multistrand /
Solid Copper conductor for 1.1 KV. to be laid on wall with necessary
clamps or in existing trench / pipe at road crossing or floor of following
size of cables. (A) 4 core 2.5 Sq. mm . (Main feeder Panel to Streetlight
162 fixtures & 3 phase machines,motor connection ). 300 mtrs. 272.34
Supplying and erecting Flexible PVC insulated multi strand multi core 1.1 kv
grade ISI marked copper wires of following size to be erected as directed.
(e) 1.50 Sq.mm 3 core round PVC sheathed. - streetlight pole box to fixture
Providing and, fixing heavy duty flange type brass cable gland with rubber
ring for PVC insulated armoured cable complete with out going tails,
insulating tape etc for following size of cables. (C) 3 & 1/2 core 70 Sq. mm
164 . (Main cable from transformer to meter panel. ). 3 nos. 104.04
Providing and, fixing heavy duty flange type brass cable gland with rubber
ring for PVC insulated armoured cable complete with out going tails,
insulating tape etc for following size of cables. (B) 2 to 4 core 6 Sq. mm.
165 (Main feeder Panel to LDB, PDB.). 15 nos. 38.76
Solder less crimping type Copper lugs conforming to IS suitable for cable of
following size evenly crimped with high pressure tool & connected to
switchgear terminals with brass/cadmium plated nut bolts in an approved
166 manner. (A) 1.5/2.5 to 6 Sq.mm. (Main feeder Panel to LDB, PDB.). 120 nos. 8.16
Solderless crimping type Copper lugs conforming to IS suitable for cable of
following size evenly crimped with high pressure tool & connected to
switchgear terminals with brass/cadmium plated nut bolts in an approved
167 manner. (B) 10 Sq.mm. 6 nos. 10.2
Solderless crimping type Aluminium lugs conforming to IS suitable for
cable of following size evenly crimped with high pressure tool & connected
to switchgear terminals with brass/cadmium plated nut bolts in an
168 approved manner. (E) 70 Sq.mm. 8 nos. 25.5
Providing & laying approved make Double walled corrugated pipes (DWC)
of polyethylene(conforming to IS 14930 II )with necessary connecting
accessories of same material at required depth for laying of cable. below
ground /road surface for enclosing cable and back filling the same to make
169 ground as per original.(A)50 mm dia. 400 mtrs. 63.24
Providing & laying approved make Double walled corrugated pipes (DWC)
of polyethylene(conforming to IS 14930 II )with necessary connecting
accessories of same material at required depth for laying of cable. below
ground /road surface for enclosing cable and back filling the same to make
170 ground as per original.(D)120 mm dia. 100 mtrs. 138.72
Supplying and erecting LED indoor fittings with LEDs of wattage 0.2 Watt to
0.5 Watt assembled on single MCPCB, with housing used as a heat sink
shall be made of thick sheet Steel conforming to IS: 513/CRCA/ aluminium
die cast powder coated and high U.V. & corrosion resistance with diffuser
with company mark/name 160V to 270V, Power Factor more than 0.9, THD
< 15%, CCT 3000 K to 6500K, Luminaire efficacy> 85 lumens/watt ,LED
LED driver efficiency > 85 % ( fitting required LM-79 & LM-80
Certificates)(NOTE: Below description have shown ranges of Wattage
capacity of LED fittings.The Engineer incharge may select any wattage
capacity between the ranges shown.). (A) Tube Light with integral driver.
171 (iii) 18-20 Watts, Surge - 2KV,IP-20, conventional 4 feet. cat III. 40 nos. 298.86
Supplying and erecting LED indoor fittings with LEDs of wattage 0.2 Watt to
0.5 Watt assembled on single MCPCB, with housing used as a heat sink
shall be made of thick sheet Steel conforming to IS: 513/CRCA/aluminium
pressure die cast powder coated and high U.V. & corrosion resistance with
diffuser housed in aluminium casted body with company mark/name
160V to 270V,Power Factor more than 0.9, THD < 15 %,
CCT 3000 K to 6500K,
Luminaire efficacy> 85 lumens/watt
LED driver efficiency > 85 %
( fitting required LM-79 & LM-80 Certificates)(NOTE: Below description
have shown ranges of Wattage capacity of LED fittings.The Engineer
incharge may select any wattage capacity between the ranges shown.).
(A) Square/ Circular shaped Surface/Recessed Mount Downlight with
provision for spring loaded mounting clips complete.IP20. (i) 5-9
172 watts,Surge-2 KV. CATIII 20 nos. 222.36
Supplying and erecting LED indoor fittings with LEDs of wattage 0.2 Watt to
0.5 Watt assembled on single MCPCB, with housing used as a heat sink
shall be made of thick sheet Steel conforming to IS: 513/CRCA/ aluminium
die cast powder coated and high U.V. & corrosion resistance with diffuser
with company mark/name 160V to 270V, Power Factor more than 0.95,
CCT 3000 K to 6500K,
Luminaire efficacy> 85 lumens/watt ,LED
LED driver efficiency > 85 %
( fitting required LM-79 & LM-80 Certificates)(NOTE: Below description
have shown ranges of Wattage capacity of LED fittings.The Engineer
incharge may select any wattage capacity between the ranges shown.)(i) 5-
173 10 Watts, Surge-2 KV, IP-20, conventional 1 to 2 feet 10 nos. 167.28
Supplying and erecting LED indoor fittings with LEDs of wattage 0.2 Watt to
0.5 Watt assembled on single MCPCB, with housing used as a heat sink
shall be made of thick sheet Steel conforming to IS: 513/CRCA/aluminium
pressure die cast powder coated and high U.V. & corrosion resistance with
diffuser housed in aluminium casted body with company mark/name
160V to 270V,Power Factor more than 0.9, THD < 15 %,
CCT 3000 K to 6500K,
Luminaire efficacy> 85 lumens/watt
LED driver efficiency > 85 %
( fitting required LM-79 & LM-80 Certificates)(NOTE: Below description
have shown ranges of Wattage capacity of LED fittings.The Engineer
incharge may select any wattage capacity between the ranges shown.).
(A) Square/ Circular shaped Surface/Recessed Mount Downlight with
provision for spring loaded mounting clips complete.IP20. (iv) 22-24 watts,
174 Surge-2 KV. 60 nos. 766.02
Supplying and erecting LED street light / Flood light fittings with High power
White LEDs wattage of 3 Watt and above assembled on single MCPCB,
efficiency more than 130 lm/w and corrosion free High pressure die cast
aluminium housing with smooth finish powder coated and heat sink
extruded aluminium with diffuser and Polycarbonate optics/ lenses with
company mark/name engraved or embossed 160 to 270 V,Power Factor
more than 0.95, THD < 10 %, CCT 3000 K to 5700K,Uniformity ratio >0.45,
Luminaire efficacy> 100 lumens/watt . LED driver efficiency > 85 %.(
fittings required LM-79 & LM-80 certificates)(NOTE: Below description have
shown ranges of Wattage capacity of LED fittings.The Engineer incharge
may select any wattage capacity between the ranges shown.). (A) Street
Light (IP-65), Surge protection -4KV integral and ,Light must have 440VAC
175 line supply with over-voltage protection. (iii) above 24 to 36 watts. Cat - III. 20 nos. 2223.6
Providing street light pole bracket consisting of Light Class MS.pipe of
cms. outside dia. complete with suitable M.S. sleeve tubing of approximate
45 cms. and length suitable for 76.5 mm / 80mm. / require size pole top
having sufficient fastners for fixing the brackets and having spread of 1 mtr.
length with suitable rise as per site condition & suitable welded stiffener
reducer and nipple with check nut complete painted with one coat of Red
oxide / PU base primer and two coats of Aluminium / PU paint. paint with
following nos of arms.
176 [A] Single Arm bracket 1 Mtr. 20 nos. 567.12
Supplying and erecting approved make Octagonal pole made from HR
sheet steel. The pole should be made as per IS. and shall be coated with
hot dip galvanizing as per IS 2629/2633/4759, suitable suspend local wind
speed with integral Junction box consist of terminal plate of min 6mm
Hylam sheet, standard profile 35mmX7.5mm Din-Rail for MCB Mounting,
stud type terminal and arrangement for cable termination to be erected
With Suitable foundation (Included) as per details given by manufacturer
considering site requirement.
(D) 6 Mtr. Long 70 mm Top X 135 mm bottom dia, 3 mm thickness with
200mmX200mmX12mm base plate, 4-M20 Bolts and 600mm long J-
177 Bolt.Approx Pole weight 59 kg. 20 nos. 8273.2
Supplying and erecting B class Galvanized iron pipe having smooth finished
bore of the pipe on both ends erected nuts and bolts along the pole / wall
shaping the pipe as per site requirement. Pipe dia as following.
Supplying & erecting approved make IP 55 grade Company fabricated
Timer Panel of following capacity for switch On-Off street lights on time
scheduling basis made from 16G CRCA sheet duly epoxy power painted
inside and outside with hinged doors and locking arrangement consisting of
suitable size of 4 Pole MCB and 4 pole contactor (cat-III)with analog time
switch, auto manual switch of same make and suitable input and output
Bakelite terminals and with door earthing approved by Engineer in charge.
Supplying & erecting approved make SMC press moulded composite FRP.
loop-in, loop-out approx. 2mm thick box complete with Bakelite connector
strip 5way(3P+N+E),DIN rail for mounting mob & hinged doors as per
requirement having locking arrangements with mounting clamp with nuts,
bolts & washers suitable for erection on pole with cable clamps& earth bolt
180 of following size of box. (C)150mm x 125mm x 100mm [deep]. 20 nos. 481.44
Making trench in soft soil of suitable width of 90 cm deep for laying cable
or locating the fault all over the run and back filling the same and making
181 the surface as normal ground. 298 mtrs. 46.92
Supplying stand first AID box with antiseptic cream, medicine for use on
wounds due burn, crepe bandage, gauge bandage, medicated ready to use
bandage (Band-aid) adhesive tape for medicinal user, Scissors, anti-septic
solution (Savlon or similar) etc. (All above contents shall be of standard
182 makes) 2 nos. 302.94
Supplying and erecting floor mounting stand for keeping four nos. of FIRE
buckets comprising 1500 mm in length, 900 mm height frame made out of
30mm X30 mm X 4 mm angle iron with cross supports for legs, welded with
4 hooks and duly painted with one coat of red lead and two coats of
183 approved enamelled silver paint. 2 nos. 951.66
Providing and fixing printed instruction chart both in English and Gujarati
and duly framed with front glasses, for treatment of person suffering from
184 Electric shock with minimum 50" diagonally size. 2 nos. 131.58
Providing & erecting open well horizontal mono block pump set with cast
iron body, complete for three phase submersible motor having[C] For 3 HP
3 phase open well horizontal mono block pump set suitable for 85 LPM to
270 LPM @ 11 mtr to 33 mtr head suitable for 50/65 mm dia delivery pipe
185 Cat. III 1 nos. 15863
Tender Value In Words
I/We am/are willing to carry out the work at…% above/below per cent (Should be writen in figures and words) of
the estimated rate mentioned above. Amount of my /our tender works out as
Estimated amount put to tender Estimated amount put to tender
Deduct………% below Deduct………% below
1 The Contractor shall exhibit a board with detailed specification and details of work as directed by the Engineer-In-
2 The labour cess will be deducted as per prevailing rules i.e. 1% of the work done
3 GST and Income tax TDS will be deducted at a source while making payments of bills
4 In all R.C.C. Items in Rate Analysis Standard Cement Consumption has been taken as per Govt. G.R.: PRC-10/2017
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
RAW_HTML
EAST ZONE LIBRARY Vol-1 .pdf
EAST ZONE LIBRARY_SBD0.1.pdf
ELEVATION1.pdf
ELEVATION2.pdf
ELEVATION3.pdf
ITEM WISE SPECIFICATION LIBRARY.pdf
Library design_plan (1).pdf
Library design_section.pdf
SCHEDUAL-B ( AS PER TENDER).pdf
Electrical work specification_Library.pdf
Bapod library amendment.pdf
26-02-2026.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .