| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹23.4 LAccepted-Finance 00 ALAHLADPUR MAIRHI CHANDAULI CHANDAULI UTTAR PRADESH 232104 | CHANDAULI | UTTAR PRADESH | 232104 | ₹23.4 L | L1 | Accepted-Finance L1 bidder |
| 2 | L2₹25.5 L+₹2.0 L (8.57%)Rejected-Finance | ₹25.5 L+₹2.0 L (8.57%) | L2 | Rejected-Finance Not L1 bidder |
| 3 | L3₹30.3 L+₹6.9 L (29.3%)Rejected-Finance | ₹30.3 L+₹6.9 L (29.3%) | L3 | Rejected-Finance Not L1 bidder |
| 4 | L4₹34.8 L+₹11.4 L (48.4%)Rejected-Finance | ₹34.8 L+₹11.4 L (48.4%) | L4 | Rejected-Finance Not L1 bidder |
| 5 | L5₹34.9 L+₹11.5 L (48.8%)Rejected-Finance 502 5TH FLOOR BUILDING NO 72 LAKSHMI BHAVAN NEHRU PLACE NEW DELHI 110019 | SOUTH EAST | DELHI | 110019 | ₹34.9 L+₹11.5 L (48.8%) | L5 | Rejected-Finance Not L1 bidder |
| Sl No | Description | Qty | Unit | Swastik Enterprises L1 | MATESHWARI ENTERPRISES L4 | Agni Green Power Ltd. L3 | MADHAV SOLAR ENERGY LIMITED L8 | Variant Infratech Private Limited L5 | Aesthetik Renewables Private Limited L6 | Virtus Techno L7 | ILIOS TECHNOLOGY L2 |
|---|---|---|---|---|---|---|---|---|---|---|---|
| 1.00 | Design, Supply, Installation, Testing and Commissioning of ongrid 60 KWp Rooftop Solar Photo voltaic Power Plant conforming to MNRE specifications as amended, consisting of Mono Crystalline silicon solarcells, netmetering facility, necessary protections, SPDs, DC and AC cables, data / control cables, earthings, safety system for reverse power protection , water cleaning system for cleaning of SPV Modules, fixed in anodized aluminium frame complete as required including elevated GI structural support systems of suitable strength to withstand the speed for the wind zone of the location with following components complete in all respect as per site conditions.Glint & Glare Hazard Analysis and submission of report to AAI is also in the scope of work.
a) Solar Photo voltaic Module of minimum capacity 540Wp or above, manufactured in India,having RF identification tag, conforming to IS14286/IEC61215,IS/IEC61730-Part-1,IS/IEC61730-Part-2 ammended up to datec. Solar Photovoltaic Module conversion efficiency shall not be less than 16.5%. PV modules used in solar power plants / systems must be warranted for their output peak watt capacity, which should not be less than 90% at the end of 10years and 80% at the end of 25 years.
b) Grid interactive Power Conditioning Unit (PCU) of 350-800 VDC Input voltage range and 400VAC, threephase, 4wire, 50Hz+/-2.5Hz, output voltage suitable to generate AC Power with efficiency not less than 97%, total harmonic distortion less than 3% and suitable for ambient temperature from 0 to 50 degree C.The PCU shall adjust the voltage and frequency level to suit the Grid Voltage Frequency.
c) Data Monitoring System complete with all accessories.
d) Fixing of Array junction box & Main junction box with IP65 protection and termination arrangement for incoming and outgoing cable along with glands, lugs and other accessories etc. as required.
e) Lightning and surge voltage protection.
f) Connections & Interconnections by supplying & fixing required size XLPE insulated copper conductor 1.1 kV grade armoured power and control cables between solar modules, main power cable to grid supply PCU unit along with supplying & fixing of necessary channel /conduit lugs and other accessories etc. as required. | 1 | Job | 21,76,350 ₹21,76,350 Lowest | 30,00,000 ₹30,00,000 | 28,25,425 ₹28,25,425 | 46,22,000 ₹46,22,000 | 31,89,500 ₹31,89,500 | 33,31,062 ₹33,31,062 | 35,40,000 ₹35,40,000 | 22,15,200 ₹22,15,200 |
| 2.10 | Comprehensive Maintenace (After defect liability period of two years) of ongrid 60 KWp Rooftop Solar Photo voltaic Power Plant including all associated systems/acessories complete taken as part of SITC in item no. 1 of various makes to ensure serviceability and unintrupted smooth operation alongwith providing & replacement of faulty components, all types of repairing works, attending breakdown along with supply of required spares, consumables, cleaning, including providing manpower for maintenan including monthly visit of qualified workmen of Agency for preventive maintenenece complete in all respect as per OEM stadard practice.
For first Year | 12 | Months | 2,800 ₹33,600 Lowest | 8,000 ₹96,000 | 2,805 ₹33,660 | 30,000 ₹3,60,000 | 5,000 ₹60,000 | 7,104 ₹85,248 | 12,500 ₹1,50,000 | 4,500 ₹54,000 |
| 2.20 | For Second Year | 12 | Months | 2,800 ₹33,600 Lowest | 8,000 ₹96,000 | 3,085 ₹37,020 | 31,666 ₹3,79,992 | 5,000 ₹60,000 | 7,104 ₹85,248 | 14,000 ₹1,68,000 | 5,000 ₹60,000 |
| 2.30 | For Third Year | 12 | Months | 2,800 ₹33,600 Lowest | 8,000 ₹96,000 | 3,394 ₹40,728 | 33,334 ₹4,00,008 | 5,000 ₹60,000 | 7,104 ₹85,248 | 16,500 ₹1,98,000 | 5,500 ₹66,000 |
| 2.40 | For Fourth Year | 12 | Months | 2,800 ₹33,600 Lowest | 8,000 ₹96,000 | 3,735 ₹44,820 | 35,000 ₹4,20,000 | 5,000 ₹60,000 | 7,104 ₹85,248 | 18,000 ₹2,16,000 | 6,000 ₹72,000 |
| 2.50 | For Fifth Year | 12 | Months | 2,800 ₹33,600 Lowest | 8,000 ₹96,000 | 4,105 ₹49,260 | 36,666 ₹4,39,992 | 5,000 ₹60,000 | 7,104 ₹85,248 | 19,500 ₹2,34,000 | 6,500 ₹78,000 |
Tender Value
₹44.7 L
EMD Value
₹1.3 L
Closing Date
13 Sept 2025, 6:00 pmClosed
AGM (EE)
O/o of AGM (EE), ATS complex MBB Airport Agartala
Design Supply Installation Testing and Commissioning of On grid 60 KWp Rooftop Solar Plant at CISF Barrack in AAI Residential Colony M.B.B. Airport, Agartala
2025_AAI_245933_1
AAI/AGT/ENGG(E)/DSITC- 60 KWp Rooftop Solar /2025-26
Open Tender
Electrical Works
Works
90 days
MBB Airport
Tender fee,Tender acceptance, PAN GST Turnover, net worth, experience certificate undertaking for debarment PQ performa and other documents etc as per NIT
4 documents required · 4 mandatory
₹1,180
₹1.3 L
MBB Airport
11 Nov 2025
22 Aug 2025
15 Sept 2025
22 Aug 2025
13 Sept 2025
22 Aug 2025
22 Aug 2025 - 29 Aug 2025
28 Aug 2025
stage.html
html • 0.06 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .