Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹65.3 LAccepted-AOC 409 2 D D A BUILDING 2 JANAK PALACE DISTRICT CENTRE JANAK PURI WEST DELHI DELHI 110058 | WEST DELHI | DELHI | 110058 | L1 | Accepted-AOC As per approval to TEC Report by the competent authority | |
| 2 | L2₹81.6 L+₹16.3 L (25.0%)Rejected-Finance | L2 | Rejected-Finance As per approval to TEC Report by the competent authority | |
| 3 | Rejected-Technical PLOT 41 A PHASE 1 R S CORPORATION COMPOUND GIDC ESTATE VITTHAL UDHYOGNAGAR ANAND GUJARAT 388121 | ANAND | GUJARAT | 388121 | - | Rejected-Technical As per Evaluation report approved by CA | |
| 4 | Not Admitted-Fee/PreQual/Technical PLOT NO 4 SHYAM M GURNANIMOTI K RAMCHANDANI PLOT NO 4 SUB SURVEY NO 1 OFF SAKI VIHAR ROAD CHANDIVLI FARM ANDHERI EAST ANDHERI E | - | Not Admitted-Fee/PreQual/Technical Not Complied with technical specification | |
| 5 | Not Admitted-Fee/PreQual/Technical | - | Not Admitted-Fee/PreQual/Technical Not Complied with technical specification |
Tender Value
Refer Docs
Closing Date
2 Jun 2021, 6:55 pmClosed
Dy. General Manager (PnC)
Dy. General Manager (PnC),Parbati HE Project, Stage-II, Parbati Complex, Nagwain, Distt. Mandi (H.P), Pin - 175 121
Restoration of 200 T EOT (Electric Overhead Travelling) cranes- supply of spares, its installation, testing and commissioning of 02 Nos. 200T EOT cranes of Power House of Parbati HE Project (Stage-II) (PROC-1854)
2021_NHPC_627641_1
NH/PP-II/PROC/1854/2021
Open Tender
Miscellaneous Goods
Supply
126 days
Power House of PHEP-II, Sainj, Kullu(H.P.)
As per Tender Document
8 documents required · 8 mandatory
₹1,180
NHPC Limited
Exempted
24 Aug 2021
23 Apr 2021
7 Jun 2021
23 Apr 2021
2 Jun 2021
23 Apr 2021
LT gear box oil seal (04 Nos Gear box) as per Sl. No.-1 of TS
LT Brake Drum EHT as per Sl. No.-2 of TS
LT Brake Drum DCEM as per Sl. No.-3 of TS
LT brake liner with Shoe as per Sl. No.-4 of TS
LT DCEM brake as per Sl. No.-5 of TS
LT EHT brake as per Sl. No.-6 of TS
LT Full Gear coupling as per Sl. No.-7 of TS
LT limit switch as per Sl. No.-8 of TS
CT gear box oil seal (02 Nos gear box) as per Sl. No.-9 of TS
CT brake liner with shoe as per Sl. No.-10 of TS
CT DCEM brake liner as per Sl. No.-11 of TS
CT limit switch as per Sl. No.-12 of TS
CT EHT brake as per Sl. No.-13 of TS
CT DCEM brake as per Sl. No.-14 of TS
CT brake drum for EHT as per Sl. No.-15 of TS
CT brake drum for DCEM as per Sl. No.-16 of TS
AH gear box oil seal as per Sl. No.-17 of TS
AH brake liner with shoe as per Sl. No.-18 of TS
AH DCEM liner as per Sl. No.-19 of TS
AH motor bearing as per Sl. No.-20 of TS
AH counter weight limit switch as per Sl. No.-21 of TS
AH limit switch as per Sl. No.-22 of TS
AH EHT brake as per Sl. No.-23 of TS
AH DECM brake (in built rectifier) as per Sl. No.-24 of TS
AH brake drum EHT as per Sl. No.-25 of TS
AH DECM Brake drum as per Sl. No.-26 of TS
MH gear box oil seal as per Sl. No.-27 of TS
MH brake DCEM (in built rectifier) as per Sl. No.-28 of TS
MH brake EHT as per Sl. No.-29 of TS
MH EHT liner with shoe as per Sl. No.-30 of TS
MH DCEM liner with shoe as per Sl. No.-31 of TS
MH brake drum EHT as per Sl. No.-32 of TS
MH limit switch as per Sl. No.-33 of TS
MH counter weight limit switch as per Sl. No.-34 of TS
LT wheel bearing(drive) as per Sl. No.-35 of TS
LT wheel bearing(idle) as per Sl. No.-36 of TS
CT wheel bearing(drive side) as per Sl. No.-37 of TS
CT wheel bearing(idle side) as per Sl. No.-38 of TS
AH DBR as per Sl. No.-39 of TS
Protective Panel main contactor as per Sl. No.-40 of TS
MH/AH main contactor (For MH/AH AC drive: 75KW, Rating: 140A, Type: PF-700 (20BC170A2AYNANCO) as per Sl. No.-41 of TS
CT main contactor (For CT AC drive: 7.5KW, Rating: 17A, Type: PF-40 (22BD017N104) as per Sl. No.-42 of TS
LT main contactor (For LT AC drive: 18.5KW, Rating: 37A, Type: PF-700 (20BC037A2AYNANA0) as per Sl. No.-43 of TS
LT & CT limit switches as per Sl. No.-44 of TS
MH/AH/CT/LT master controller as per Sl. No.-45 of TS
Contactor as per Sl. No.-46 of TS
Contactor as per Sl. No.-47 of TS
Contactor as per Sl. No.-48 of TS
H.R.C fuse as per Sl. No.-49 of TS
H.R.C fuse as per Sl. No.-50 of TS
H.R.C fuse as per Sl. No.-51 of TS
Contactor as per Sl. No.-52 of TS
Contactor as per Sl. No.-53 of TS
Contactor as per Sl. No.-54 of TS
CT AC drive as per Sl. No.-55 of TS
Grease nipple as per Sl. No.-56 of TS
Panel lock all panel as per Sl. No.-57 of TS
LT main MCCB as per Sl. No.-58 of TS
CT DBR as per Sl. No.-59 of TS
LT DBR as per Sl. No.-60 of TS
MCB /CT as per Sl. No.-61 of TS
MH power switch fuse unit as per Sl. No.-62 of TS
PP main isolating switch as per Sl. No.-63 of TS
MH DBR as per Sl. No.-64 of TS
CT AC drive as per Sl. No.-65 of TS
CT MCB as per Sl. No.-66 of TS
LT Motor(S.Q cage) bearing for DE & NDE as per Sl. No.-67 of TS
Monorail CT Motor(S.Q cage) bearing for DE & NDE as per Sl. No.-68 of TS
Monorail Hoist Motor(S.Q cage) bearing for DE & NDE as per Sl. No.-69 of TS
Installation, testing and commissioning charges for EOT Cranes
MADHAVI INDUSTRIES PVT LTD
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.PDF
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .