Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.1 LAccepted-AOC | L1 | Accepted-AOC L1 | |
| 2 | L2₹1.2 L+₹7,300 (6.47%)Rejected-AOC CHATHANADU HOUSE CHEMBUMUKKU | L2 | Rejected-AOC HIGHER RATE HENCE REJECTED |
Tender Value
₹1.2 L
EMD Value
₹3,064
Closing Date
14 Oct 2024, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Assistant Executive Engineer, LID EW Section,
Assistant Executive Engineer, LID EW Section,
SITC of AC in Anganavadi no. 65 in Dvn 15.-SITC of AC in Anganavadi no. 65 in Dvn 15.under Thrikkakara Municipality(Pro. S0172/25)
2024_LSGD_693659_41
LIDEW/AEE/ET/08/2024
Open Tender
Electrical Works
Item Rate
180 days
THRIKKAKARA
Please refer Tender documents.
8 documents required · 8 mandatory
₹555
₹3,064
29 Jan 2025
7 Oct 2024
16 Oct 2024
7 Oct 2024
14 Oct 2024
7 Oct 2024
Amount
SITC of AC and allied work
OD120512/2023-2024:Supply and provide voltage stabilizer ( suitable for up to 2 TR AC)for split type A/C unit with voltage range of 175-275V and out put range of 210 - 240V.(V-Guard VG 400 PLUS STABILIZER or equalent )
OD294487/2023-2024:SITC of Inverter type wall mounting split air conditioner unit of the folloinig rating conforming to relevant IS suitable for operating on 230v. 50 hz single phase AC supply filled with R 410 A refrigent gas high energy efficient. RoHS complaint. capable of performing function like cooling , dehumidifing, air circulatting, filtering etc of following capacity including refrigent copper piping 3m with insulation, control cable up to 5m, 3m drum pipe. condensor stand ,microprocessor control with cord less remote controletc with one year warrenty for machine and one year 4 Nos free service. 1. TR inverter type split AC unit. (VOLTAS AC 1. T, 3S, VECTRA ELEGENT or equalent )
OD294488/2023-2024:SITC of Inverter type wall mounting split air conditioner unit of the folloinig rating conforming to relevant IS suitable for operating on 230v. 50 hz single phase AC supply filled with R 410 A refrigent gas high energy efficient. RoHS complaint. capable of performing function like cooling , dehumidifing, air circulatting, filtering etc of following capacity including refrigent copper piping 3m with insulation, control cable up to 5m, 3m drum pipe. condensor stand ,microprocessor control with cord less remote control etc with one year warrenty for machine and one year 4 Nos free service. -1.5 TR inverter type split AC unit. (VOLTAS A/C 1.5 T, 3S, VECTRA PRISM or equalent )
OD120515/2023-2024:Suply and providing metalic frame for the out door unit of the above AC unit as required.
OD124921/2023-2024:Supply and provide Smart LED TV, with company make wall / Table bracket ,80 cm( 32 inch ) SONY make model No.KD-32W 830 K 80cm.
OD120516/2023-2024:Suply and providing the following size hard drawn copper refrigerant pipe for the extending the pipe between out door and indoor unit. Including the pipe using rubberised foam sleev 10mm thick, brazing,leak testing etc. (for extending length of pipe beyoned standard length supplied with the unit)12.5mm ( 1/2" )Outer dia 22SWG.
OD120517/2023-2024:Suply and providing the following size hard drawn copper refrigerant pipe for the extending the pipe between out door and indoor unit. Including the pipe using rubberised foam sleev 10mm thick, brazing,leak testing etc. (for extending length of pipe beyoned standard length supplied with the unit)19.5mm ( 3/4" )OD 22SWG
90.6.5.13:Supply and drawing the following sizes of multi-core PVC insulated & FRLS PVC sheathed 650/1100 V grade copper conductor round flexible cables conforming to IS 694 part I 1960 in the existing surface / recess conduit as required including giving necessary connections of the following sizes.3 core 4.00 sq mm
90.6.10.1:Supply and fixing of following sizes of light gauge PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required20 mm
90.6.10.2:Supply and fixing of following sizes of light gauge PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required25 mm
90.6.10.3:Supply and fixing of following sizes of light gauge PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required32 mm
90.10.3.14:Supply and Fixing the following modular switches & accessories in the existing front plates and giving necessary connections as required (RoHS compliant )25A SP switch with indicator
90.10.3.32:Supply and Fixing the following modular switches & accessories in the existing front plates and giving necessary connections as required (RoHS compliant )25A 3 pin plug top with indicator
90.10.3.33:Supply and Fixing the following modular switches & accessories in the existing front plates and giving necessary connections as required (RoHS compliant )25A 3pin Shuttered socket
1.17.20:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.2 x 4 sq. mm
1.17.22:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.4 x 4 sq. mm
1.27.1:Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.1 or 2 Module (75mmX75mm)
90.16.1.1:Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required2.00 mm copper conductor ( 14 SWG)
2.10.1:Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Single pole
90.16.5.1:Supply of superior quality copper earth socket for the following size of earth conductor including crimping etc. as required.2.00 mm (14 SWG)
OD294526/2023-2024:Supply and provide 25 x 6 mm brass nut 7bolt with washer
AKHIL SAJEEVAN
Bidder Name
V S SAJEEVAN
AKHIL SAJEEVAN
tech_eval.pdf
fin_eval.pdf
aoc.pdf
finance_1082111.pdf
boq_comp_chart.xlsx
xlsx
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .